Вы находитесь на странице: 1из 6

pwps

220 kV AllXLPElLSlHDPE l X 8 0 0 mm2

@ dmd?e

suecification : IEC 62067 whereauulicaable

s G n e r a l bblr company

PHELPS DODGE THAILAND LIMITED

- P n

Extrudec Semi-conductive Layer

7-----------d------------------<-----------*------w-------*-------7

I
230 kV CUIXLPEILSIHDPE 1 x 8 0 0 mm2
'~--------,---------------------------------------------#-----------<2

220 kV AIIXLPEILSIHDPE 1X800 rnm2

Where

IS,
: Permissible fault current (kA)

: Cross-sectional area of the current carrying component (mm2)

: Number of shield

: Constant depending on the material of the current carrying component ( ~ . " ~ / r n m ~ )

: Duration of fault current (seconds)

: Factor to allow for heat loss into the asjacent components

0i

: Initial temperature ("C)

0f

: Final temperature ("C)

: Reciprocal of temperature coefficient of resistance at 0 OC

Parameters

Wire Shield

Tape Shield

Armour

ISC

I Lead Sheath

Reference : IEC Standard Publication No. 949: Calculation of thermally permissible short-circuit

currents, taking into account non-adiabatic heating effects.

25.19

SCHEDULE D - TECHNICAL PARTICULARS CONT


SCHEDULE D4 - 230 KV POWER CABLES
230 KV POWER CABLES

'-1

UNIT

1.

GENERAL

1 .I

Name of manufacturer

1.2

Place of manufacture

1.3

Manufacturers type or drawing reference number

1.4

Circuit rating required

1.5

Constructional and Testing standards


Standard@) to which cable complies

DATA
Required
Offered
Pheips Dodge
International
(Thailand)Lld.
Thailand
By Sales

MVA

175

175
IEC 62067

1 General description of cable


Voltage designation UdU(Um)
Number of cores
Conductor size
Cotductor material
Type of insulation
Type of melal screenlshealh
Type of armour
Type of wersheath

1
2.1

2.2

2.3

Year of first commercial operation of cable type


CONSTRUCTIONAL FEATURES
Conductor
Material
Nominal uoss-section
Type of conductor
Overall diameter (Approx.)
Waterblocking method
Semiconducting binder tape
Conductor screen
Type of material

Nominal thickness (Approx.)


Insulation
Material
Thickness: Minimum average
Thickness: Minimum at a m i n t

IN o t e 1: The Cont~actot
Nominal werall diameter
shall subtn~tanDroDllate calculal ons
transmit 440A per circuit. The cables i l l
to the Telder Drawings

be laid down in con,Crete trenches, and duct banks according


41

Volume 4 - 230kV S l P W Suk.tation Schedules FINAL

SCHEDULE 0 -TECHNICAL PARTICULARS - CONT

SCHEDULE D4 - 230 KV POWER CABLES Con1


230 KV POWER CABLES

2.4

UNIT

Insulation screen
Type of material

Nominal thickness (Min.Avg.)

2.5

XLPE Manufacturing Methods


Extrusion line type e.g. CCV
Single pass, triple extrusion
- Curing method
- Cooling method

mm

DATA
Required
Otfered

Extruded semi Extrude semi


conductive, conductive XLF I
cross-linkable
1.2

2.6

Bedding (il applicable)


Type and material

2.7

Metallic
on each core
Type and material

VCV or CCV

Yes
Dly cure
Water wol or
gas cool

yeslno

Semi conductibi
water blocking ;

Sheath

+mr
Nominal thickness (Min.Avg.)
mm
Nominal diameter over the screen ( A ~ ~ ~ ~ ~ . mm
)

2.8

2.9

2.10

2.1 1

Volume 4

Bedding layer
Type and material
Nominal thickness
Minimum thickness

Protective anti-corrosion external sheath covering


Type and material
Colour
Nominal thickness
Minimum thickness
Termite resistant
Type of anti-termite protection
Nominal overall cable diameter

NIA
NIA

mm
mrn

Armwr
Nominal diameter under the armour
Type and material
Armour wire diameter or dimensions of strip

(Approx.)

- 230kV SlPCOSubstatim S M u l e s FINAL

NIA
NIA
NIA
NIA

rnrn
mm

MOPE
mrn
rnm
yeslno

Lead Alloy 1/21


or Alloy E
3.2
101.8

Yes

HDPE
Black
4.2
3.47
Yes
ANTI-TERMITE

mrn

MASTERBATCH
112

SCHEDULE D - TECHNICAL PARTICULARS


SCHEDULE D4

- 230 K V POWER CABLES - Con1

230 KV POWER CABLES


2.12

3
3.1

3.2

3.3

Weight d comBleted cable

Maximum continuous rating! direct-buried, assuming:


Ground temperature at burial depth of 35%
Soil thermal resistivity of 2.5K.m.W
Depth of laying O.8m
Thermally independent of other cable circuits
trefoil touching (solid bonded)
flat formation spaced at one cable diameter (single
point bonded)
Calculation Method
Maximum continuous rating, in singleway ducts,
assuming:
Ground temperature at burial depth of 35%
Soil thermal resistivity of 2.5K.mAV
Depth of laying O.8m
Thermally independent of other cable circuits
trefoil touching (solid bonded)
flat touching formation (single point bonded)
Calculation Method
Mmimum continuous rating, in-air, assuming:
Air temperature (in shade) of 50C
Thermally independent of other cable circuits
trefoil touching (6olid bonded)
flat formation spaced at one cable diameter (single
point bonded)
Calculation Method
Maximum permissible conductor temperature for
continuous operation

3.5

Conductor short circuit capacity


Short circuit current
Duration
Permissible maximum temperature

4.1

UNIT

DATA
Required
Offered

kg'm

20.3

A
A

471

CURRENT RATINGS

3.4

3.6

- CONT

Screen Iarmour shorl circuit capacity


Short circuit current
Duration
Permissible maximum temperature

547
IEC 60287

494

A
A

511

IEC 60287

IEC 60287

IEC 80287
90

OC

s
O
C

IEC 60287

812
932

A
A

IEC 60287

50
1
250

75.6
I

250
25.2

M
6

OC

200

200

ELECTRICAL CHARACTERISTICS
DC resistance of conductor at 20'C

Volume 4 - 230kV SlPCOSuhslatim Schedules FINAL

Nm

0.0367 x to"

SCHEDULE D - TECHNICAL PARTICULARS CONT


SCHEDULE D4

- 230 KV POWER CABLES - Con1

230 KV POWER CABLES


4.2

UNIT

DATA
Required
Offered

AC resistance of conductor at 50 Hz and maximum


conductor temperature
trefoil touching (solid bonded)
flat formation (single point bonded)

Mm

Clfm

0.0494 x 1 O"
0.0492 x 1CC3

Positive Sequence Resistance of cable at 50 Hz


trefoil touching (solid bonded)
flat formation (single point bonded)

Cl!m
Clfm
Il!m

0.0494x 1 Ci3
0.0492x 1 0-3

Positive Sequence Reactance of cable at 50 Hz


trefoil touching (solid bonded)
flat formation (single point bonded)

CYni
CYm
D'm

4.5

Zero Sequence Resistance of caMe at 50 Hz in trefoil


touching formation (solid bonded)

4.6

4.7

4.3

4.4

ah.

0.1288 x
0.1433x

loJ

DJm

0.3171 x

lo-=

Zero Sequence Reactance of cable at 50 Hz in trefoil


touching formation (solid bonded)

Mm

0.0836 x 10"

Capacitance per core

pFlm

167

LOSSES
Tolal losses per three phase circuit when operating at
nominal voltage and 50Hz and at the current ratings
stated in Item 2 :
laid direct in trefoil touching (solid bonded)
laid direct in flat formation (single point bonded)

Wlm

Wlm
Wlm

40.8
47.2

in ducts in trefoil touching (solid bonded)


in ducts in flat touching formation
(single point bonded)
in air in treloil touching (solid bonded)
in air in fiat formation (single point banded)
INSTALLATION DATA

Wlm
Wlm

44.6
42.4

Wlm
Wlm

116.9
132.7

Minimum cable bendirg radius when laid:


During installation
Adjacent to joints and terminations

mm
mln

3920
3360

6.2

Minimum internal diameter of pipes or ducts (Approx.)

mm

154

6.2

Maximum permissible pulling force of total cable

kN

56

5.1

6.1

COMMISSIONING TESTS
Recommended tests after all tetminating and jointing
has been completed but before connection to the
system.

7.1

By Sales

44

Volume 4 BOkV SlPCOSutsratia> Schedules FINAL