Вы находитесь на странице: 1из 1

PROJECT KEY PLAN

NOTES:
N1

TUNDISH'S SHALL BE PROVIDED WITH


MINIUM 40MM TRAP

N2

DISHWASHER(IN KITCHEN) SHALL NOT


CONNECT TO TRADE WASTE DRAINAGE

N3

100MM INDUSTRIAL FLOORWASTE GULLY


TO BE PROVIDED

ZONE A

ZONE B

ZONE C
N

10

11

12

D2
D1

N1

AIRLOCK
ED-05

FRS

HB-UAT UAT/SHRWC-UAT

DU-SK

HB-B

ST. BASE

FW

IP-02

HB-B

SHR

ENS.

ENS.

IP-04

IP-07

ED-12

IP-24

IL 5.885
COS
ED-08

IL 5.833

WC-1

HB-B

HB-B

HB-A

MI-02

MI-03

RESUS

CORRIDOR

ED-10

IP-23

HB-B

ACUTE TREAT.
ED-09

IO

GWVP

IP-22

BALCONY
IP-27

IP-20

REV:

HB-C
CSK

C2

SK.
TD

DESCRIPTION

DATE

APPR

ISSUED FOR TENDER

01.07.16

GG

ISSUED FOR TENDER

14.07.16

GG

BWU/CHWU

65 SD @2.50%

1 BED
IP-15

EQUIP. ST.
GENERAL STORE
IP-16

IP-17

PAT. LOUNGE
IP-19

D2

IO

100
DB SD @1.65%

D1

BS-06

100 SD @1.65%

COS

VP

50

COS

P.WC FWG

LINEN BAY

22
CORRIDOR

WC-1

IO

IP-21

COS
VP
--50

CORRIDOR
IP-25

N1

HB-B

IP-12

BB
TD

WC FWG

B2

HB-ENS

HB-ENS

FWG IP-18

HB-BAR

1 BED

S.WC

SHR

HB-B

65 SD @2.50%

ELEC

ENS.
IP-14

HB-B

GTVP
BS-02

ENS.
IP-13

WC-ENS

TD

MI-01

110

IP-11

IP-26

TD

50

MEDICAL IMAGING

ENS.

100 SD @1.65%

WC-BAR

HB-ENS

N1

ENS.
IP-08

CLNR

N1

VP

HB-B

SHR

HB-ENS

65 SD @2.50%

CH.

CORRIDOR

N1

COS

COS
SHR

WC-ENS

FWG
B

IP-10

IL 5.889
COS
SHR

IL 5.875
P.WC

1 BED

IP-09

COS

WC-ENS WC-ENS

FFL: 6.50m

100 SD @1.65%

PATHOLOGY
ED-07

CORRIDOR

1 BED

65 SD @2.50%

HB-B

COS

HB-ENS

CORRIDOR

100 SD @1.65%

100 SD @1.65%

HB-B

SHR

SHR

IO

TD
65 SD @2.50%

TD

HB-B

IO

TD

N1

COS
WC-ENS

ED-06

1 BED
IP-06

FRS
HB-B

TD

N1

1 BED
IP-05

IO

100 SD @1.65%

DU/DISPOS.
IP-03

LSK

ISSUE FOR TENDER

IL 4.742

NOT FOR CONSTRUCTION

COS

IL 4.994

50

TD

Check all dimensions on site before commencing. Work to figured


dimensions, report any discrepancies to the Architect for decision

DWM

IL 5.109

%
D @1.65
110 GW

COS
@1.65%

IL 5.885

KITCHEN
KT-01

N3

K-DSK

be retained, copied or used without authority from the Architect

K-DSK

N2

Building Services Consultant:

FWG

STAFF ROOM
ST-01

K-HB

IL 5.969

IWFG

N3

K-HB

@
100 SD

1.65%

IWFG

IL 5.259

COS

FFL: 6.50m

K-SK

MEETING ROOM

OFFICE
IL 5.163

FRIDGE ALCOVE
DRY STORE

Level 4, 533 Hay Street,


Perth (WA) 6000
PO BOX 5757, St Georges Terrace
(WA) 6831
Ph (08) 9322 9514
Fax (08) 9486 7428
A.C.N.: 111 500 415
A.B.N.: 45 111 500 415 002
email: perth@sppgroup.com.au
web: www.sppgroup.com.au

@1.65%

FWG

IWFG

N3

N3

TD

before proceeding to work. This drawing is copyright and is not to

IL 5.025

100 SD

IL 5.844

IWFG
FWG

SK.

BWU/CHWU

IL 6.025

@1.65%
100 SD

DESCRIPTION

WRITE-UP
IP-01

IO

100 SD @1.65%

ED-04

STER

100 SD @1.65%

100 SD @1.65%
65 SD @1.65%

ED-03

CU/DRUGS

MAC

COS

2,000L GREASE ARRESTOR


LOCATE AS DIRECTED ON SITE.

KEYNOTE LEGEND

BASIN
BABY BATH
CLEAR OUT TO SURFACE
CLEANERS SINK
DIRTY UTLITY SINK
FLUSHING RIM SINK
FLOORWASTE (UNTRAPPED)
FLOORWASTE GULLY (TRAPPED)
GREASE ARRESTOR
BASIN TYPE A
BASIN TYPE B
BASIN BARIATRIC
BASIN TYPE C
HAND BASIN ENSUITE
ACCESIBLE HAND BASIN
INSPECTION OPENING
INDUSTRIAL FLOOR WASTE GULLY
INDUSTRIAL WASTE SAMPLING POINT
KITCHEN DOUBLE BOWL SINK
HAND BASIN KITCHEN
KITCHEN SINK
MACERATOR
OVERFLOW RELIEF GULLY
SHOWER
SINK - SINGLE WITH DRAINER
STERILISER
TUNDISH
WATER CLOSET
WC
WC BARIATRIC
WC ENSUITE
WC ACCESSIBLE

PROCEDURE

IO

100 SD @1.65%

65 SD @1.65%

TD

SK.

65 SD @1.65%

INTERVIEW
ED-02

HB-A

65 SD @2.50%

TRIAGE
ED-01

GA

B
BB
COS
CSK
DU-SK
FRS
FW
FWG
GA
HB-A
HB-B
HB-BAR
HB-C
HB-ENS
HB-UAT
IO
IWFG
IWSP
K-DSK
K-HB
K-SK
MAC
ORG
SHR
SK.
STER
TD
WC
WC-1
WC-BAR
WC-ENS
WC-UAT

100 SD @1.65%

COS

D
110 GW

FIXTURE

PROVIDE WASTE FOR


MACERATOR - TBC BY CLIENT
ORG

ORG

AD-13

COS

IFWG

CORRIDOR

PR

100 SD @1.65%

100 SD @1.65%

C1

17

IL 4.261

100 SD @1.65%

C2

16

IWSP

100 SD @1.65%

B1

15

COS

100 SD @1.65%

COS

65 SD @2.50%

REFER TO DRAWING H-100 FOR CONTINUATION

B2

14

PROVIDE TUNDISH FOR


RPZD VALVES WITH AIR
GAP IN ACCORDANCE
WITH AS3500

IL 3.639

13

ST-02

KT-04

FS 531157

KT-03

KT-02

REFER TO DRAWING H-102 FOR CONTINUATION

Government of Western Australia


Department of Finance

18

19

20

21

22

Building Management and Works

ONSLOW HEALTH SERVICE DEVELOPMENT


SECOND AVENUE, ONSLOW (WA) 6710
GROUND LEVEL ZONE B - DRAINAGE SERVICES
DRAWN

GENERAL NOTES:
COORDINATE MECHANICAL TUNDISH
LOCATIONS ON SITE WITH MECHANICAL
SERVICES CONTRACTOR.

DESIGNED

XF
CHECKED
GG
APPROVED
GG
SCALE
1 : 100 @ A1
BMW PROJ No.
14062

REDUCTION
MJ

PRINCIPAL

DATE

25

DRAWING No.

REV.

14.07.16
BMW File No.
2016/01030

THIS IS A CADD DRAWING


DO NOT AMEND MANUALLY

H - 101
BA JOB NO:

01
150015