Operating Instructions V15 with AS-Interface

The V15 with AS-Interface has 8 inputs and 8 outputs. The V15 AS-i interface occupies 2 addresses
(connection 1 and connection 2) in the AS-i-system. Power to the valves are supplied by the black cable (24V
DC), so it is possible to switch off the valves separately (Emergency OFF).
The addresses are programmed by using a standard programming device. The plugs the programming
devices will be connected with, are installed behind the covering screw on the top side of the housing. It is not
necessary to disconnect the AS-i cable while defining the addresses. The address for the different
connections are configured individually via separate plugs. For the connection of the addressing device with
the interface a special address-cable is necessary (Order-No. 894 605 449 2). Addresses from 1 31 are
valid. It is possible to change the address 15 times, after that the last valid value remains. To ensure the
operational reliability of the system, the valves power supply has to be switched off during the
configuration of the addresses.

Ini connector 1
Ini connector 2
Ini connector 3
Ini connector 4

AS-i connection 1 controls the first 4 coils at the valve-unit, connection 2 the next 4 coils. Active outputs are
indicated with yellow LEDs.
Sensors with 2 and 3 conductor technique can be connected to the input M12 plugs. The sensors are
supplied by the AS-i-interface (see Table 1). This supply is short circuit protected.
Buchse
1
2
3
4

Pin1
20V to 30V
20V to 30V
20V to 30V
20V to 30V

DC
DC
DC
DC

Pin2
Input
Input
Input
Input

1 Pin 1
3 Pin 1
1 Pin 2
3 Pin 2

Pin3
0V
0V
0V
0V

Pin4
Input
Input
Input
Input

0 Pin 1
2 Pin 1
0 Pin 2
2 Pin 2

Table 1: Pin configuration for the input signals


The LED AUX indicates the voltage supply for the valves (LED on: 24 V-valves available) . A red and a
green LED indicate the operational condition of each AS-i connection. In case of discontinuation of the
BUS-communication (failure of the master) the outputs of the valves will be reset after 40 ...100 ms
(watchdog).
AS-i (green)
On
Off
Off
Flashing
Off

FAULT (red)
Off
Off
On
On
Flashing

Bottom view

LED's AS-i 1
LED's AS-i 2
LED valve power supply
LED's Output 1, Channel 0
.
.
.
LED's Output 2, Channel 3

Valves power supply


Sensor signal (LED green)
Sensor power supply

ID-Code
IO-Code
Current consumption
Reverse battery protection
Voltage PELV
acceptable current load
for signal 0
for signal 1
Voltage range
acceptable current load
Table 3: Technical Data

885 890 366 3 / V15 AS-i / 26.10.2000

F
7
300 mA
Existing
24V 10%
100mA short circuit protected
Iin 1,5mA
Iin 5 mA / Uin 10V
20V-30V DC
2 x 100mA short circuit protected

OUT IN
1.0
1.1
1.2
1.3
2.0
2.1
2.2
2.3

12

12

12

12

Name tag slot

Manual operation
14

14

14

Lock screw

Operational condition
Module OK
No supply voltage at AS-interface chip
No communication
Slave has address 0
Overload sensor supply / no communication with the master

Front view

Table 2: Operational conditions of the AS-i


Technical Data
AS-i Data

FAULT AS-i
1
2
AUX

AS-Interface
Valve power supply
Programming plug 2
Programming plug 1
Top view

Вам также может понравиться