Equipments:
SCR;
Resistors: 220
Potentiometer; Extech Resistance Decade Box
Multimeter
Trainer Board
Bench Power Supply
Circuit Diagram:
Theory:
Procedure:
The value of V1 & V2 was set to +10 VDC & +15 VDC
Voltage reading was taken by Multimeter between Anode &
Cathode (VAK) of the SCR.
Similarly voltage reading was taken by Multimeter between R1
(220 ) & R2 (RG) (Potentiometer).
The IG current was measured by dividing the voltage drop across
the R2 (RG) Resistor with the current value or R2 resistor. IG=VR2/R2
R2 value was changed & VR2 was measured for different R2
values.
Different values were measured & logged on a Data Table.
Data Collection:
RG
VG
IG=VG/RG
VR1
IR1=VR1/20
0
1M
10.32 V
0.01032
mA
13.17 V
0.06585
10 K
10.77 V
1.077 mA
13.20 V
0.66
2K
11 V
5.5 mA
13.16 V
0.6058
Discussion: