Вы находитесь на странице: 1из 680

09/2016

WHO WE ARE
WE WANT TO CONTINUE THAT WHICH WAS STARTED MANY YEARS AGO BY VINICIO
METTIFOGO, FOUNDER AND PIONEER.
Calpeda is a family owned company with an history of 58 years.
Today, we are a reality that has evolved over the years, always looking to the future
with a spirit that has brought us to being a respected reference point in the great
world of water.
Our history has taken our tradition and strength to you, acknowledged for our
professionalism, quality, reliability and service.

CALPEDA TODAY
Employees: 250
Offices: Montorso V. (Vicenza) Italy
Main factory: 30,000 sq. metres (covered)
Types of pumps: more than 2,000
Power outputs: from 0.5 kW to 200 kW

INDEX
1 pag. 7

NM, NMD

Close coupled centrifugal pumps


with threaded ports

2 pag. 19

NM(EI), NMS

Close coupled centrifugal pumps


with flanged connections

3 pag. 31

NM4(EI), NMS4

Close coupled centrifugal pumps


n = 1450 rpm

4 pag. 47

N, N4

End-suction centrifugal pumps


EN 733

5 pag. 73

NR(EI), NR4(EI)

In-line pumps

6 pag. 85

MXH(EI), MXHL

Horizontal multi-stage
stainless steel pumps AISI 304, AISI 316L

7 pag. 97

MXP

Horizontal multi-stage
close coupled pumps

8 pag. 99

MGP

Horizontal multi-stage
close coupled pumps

9 pag. 101

MXSU

13 pag. 137

MPC Compact Pool

Self-priming swimming pool pumps

14 pag. 141

NMP

Self-priming centrifugal pumps


with built-in strainer

15 pag. 145

PF

Pre-filters in stainless steel

16 pag. 147

Self-priming centrifugal pumps


with open impeller

17 pag. 153

Centrifugal pumps
with open impeller

18 pag. 159

CT

Peripheral pumps

19 pag. 163

T, TP

Peripheral pumps

20 pag. 169

CA

Self-priming liquid ring pumps

21 pag. 173

NGL

Vertical multi-stage close coupled


stainless steel pumps

Self-priming pumps

10 pag. 105

22 pag. 177

MXV-B(EI)

Vertical multi-stage close coupled


stainless steel pumps

11 pag. 111

MXV(EI), MXVL

Vertical multi-stage
stainless steel pumps AISI 304, AISI 316L

12 pag. 135

SPA Compact Spa

Self-draining whirpool pumps

NGX

Self-priming pumps

23 pag. 181

NG

Self-priming pumps

24 pag. 189

MXA

Horizontal multi-stage
Self-priming pumps

25 pag. 191

37 pag. 301

I, IR

Automatic waste water collecting


and lifting station

Gear pumps

26 pag. 193

GEO

38 pag. 327

B-VT

MP

Peripheral immersion pumps

Multi-stage submersible
clean water pumps

27 pag. 195

39 pag. 331

VAL, SC

MPS

Vertical submerged pumps

Multi-stage submersible
clean water pumps

28 pag. 199

40 pag. 335

GM 10

NEW

MXS

Submersible drainage pump

Stainless steel multi-stage submersible


clean water pumps

29 pag. 201

41 pag. 339

GXR, GXV

NEW

SFM 70

Submersible stainless steel pumps

Peripheral submersible
borehole pumps for 4 wells

30 pag. 213

42 pag. 341

GQR

SD, SDF, SDN

Submersible drainage pumps

Submersible borehole pumps


for 4and 6 wells

31 pag. 217

43 pag. 358

GX 40

SDX

Submersible stainless steel pumps

Stainless steel submersible borehole


pumps for 6 and 8 wells

32 pag. 221

44 pag. 371

GQS, GQV

SDS

Submersible sewage and


drainage pumps

Submersible borehole pumps


for 6 - 8 and 10 wells

33 pag. 225

45 pag. 383

GM 50

CS, FK

Submersible sewage and drainage pumps

Submersible motors
for 4 - 6 - 8 and 10 wells

34 pag. 229

46 pag. 395

GQG

NEW

Submersible pumps
with high power grinder

35 pag. 233

GM

Submersible pumps

36 pag. 295

GEO

GEOTRIT - GEOCOMP - GEOCLEAN


Automatic lifting station

NCE

Heating and conditioning

47 pag. 465

NEW

IDROMAT
NEW

Electronic regulator for pumps

48 pag. 471

EASYMAT

Variable speed system driven


by frequency converter

INDEX
49 pag. 475

VARIOMAT 2

Variable speed system driven


by frequency converter

50 pag. 477

I-MAT

NEW

Variable speed system driven


by frequency converter

51 pag. 481

BS

Pressure boosttiing setts

52 pag. 571 AUE, AUD, AUED


UNI-EN 12845 units for feeding
fire-extinguishing systems

53 pag. 591

QM, QT

Control panels

54 pag. 616 Accessories


Accessories for pumps

BATTENTE POSITIVO IN
ASPIRAZIONE (m.c.a.)

TEMPERATURA ACQUA IN GRADI CENTIGRADI


5

10

20

10

20

30

40

50

60

70

80

90

100

110

50

60

70

80

90

100

110

4
3
2
1
0

55 pag. 623

PREVALENZA MANOMETRICA IN
ASPIRAZIONE (m.c.a.)

2
3
4
5

TIC

A
A PR
CURV

6
7
8
9

CURVA

TEO R

I CA

10
11

30

40

TEMPERATURA ACQUA IN GRADI CENTIGRADI

Technical appendix

09/2016

NM, NMD

Close Coupled Centrifugal Pumps


with threaded ports

Construction
Close-coupled, centrifugal pumps; electric motor with
extended shaft directly connected to the pump.
NM: single-impeller
NMD: with two back-to-back impellers (with axial thrust balancing).
Connections: threaded ports ISO228/1 (BS 2779).
NM, NMD: version with pump casing and lantern bracket in cast iron.
B-NM, B-NMD: version with pump casing and lantern bracket in bronze.
(the pumps are supplied fully painted).

Applications
For clean liquids without abrasives, which are non-aggressive for
the pump materials ( solids content up to 0.2%).
For water supply.
For heating, air-conditioning, cooling and circulation plants.
For civil and industrial applications.
For fire fighting applications. For irrigation.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar
(16 bar for pumps NMD 25/190; NMD 32/210; NMD 40/180).
Continuous duty.

Motor

The electropumps NM, B-NM series comply with the European Regulation no.
547/2012.

2-pole induction motor, 50 Hz (n 2900 rpm).


NM, NMD:
three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% from 4 to 9,2 kW;
NMM, NMDM: single-phase 230 V 10%, with thermal protector.
Insulation class F. Protection IP 54.
Motor suitable for operation with frequency converter from 2,2 kW.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from7,5 kW.
Constructed in accordance with EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components
Pump casing
Lantern bracket

NM, NMD
Cast iron
GJL 200 EN 1561

B-NM, B-NMD
Bronze
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cr steel AISI 430
Cr Ni Mo steel
Cr Ni steel AISI 303
AISI 316
1,1 -1,5 - 2,2 kW

Impeller
NM 17
Shaft

Mechanical seal

Special features on request


- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Protection IP55. - Special mechanical seal
- Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 1,5 kW.

Carbon - Ceramic - NBR

Coverage chart n 2900 rpm


4

Imp. g.p.m.

U.S. g.p.m.

10

20

10

20

30
30

40
40

50

100

50

200

100

200

300
300

400

130

400
NMD 32/210

100

300

NMD 25/190

NMD 40/180

200

NMD 20/140

50

NM 3

40

NM
12

NM 25/20

ft

NM 20/160

30

100

NMD 20/110

NM 25/160

NM 11

NM 2
20
NM 25/12

NM 1

50
NM 10

40

NM 17
10

30
20

5
4
1

m 3/h

Q l/min 30

2
40

3
50

6 7
100

8 9 10
200
150

20
300
400

30
500

40

50
1000

100
1500
72.820.C

NM, NMD

Close Coupled Centrifugal Pumps


with threaded ports

Performance n 2900 rpm

P2

NM

NM
NM
NM
NM
NMM
NM
NMM
NM
NMM
NM

B-NM
B-NMD
B-NMD
B-NMD
B-NMD
B-NMDM
B-NMD
B-NMDM
B-NMD
B-NM
B-NM

20/110B/A
20/110Z/A
20/110A/A
20/140BE
20/140BE
20/140AE
20/140AE
20/160BE
20/160AE

B-NM
B-NMD
B-NM
B-NM
B-NM
B-NM
B-NM
B-NM
B-NM
B-NMD
B-NMD
B-NMD

25/12B/A
25/12A/A
25/160BE
25/160AE
25/200B/B
25/200A/B
25/200S/B
25/190C/A
25/190B/A
25/190A/A

1/AE
2/B/A
2/S/A
2/A/A
3/CE
3/CE
3/BE
3/BE
3/A/A
3/A/A

NM
NMD
NMD
NMD
NMD
NMDM
NMD
NMDM
NMD
NM
NM

20/110B/A
20/110Z/A
20/110A/A
20/140BE
20/140BE
20/140AE
20/140AE
20/160BE
20/160AE

NM
NMD
NM
NM
NM
NM
NM
NM
NM
NMD
NMD
NMD

25/12B/A
25/12A/A
25/160BE
25/160AE
25/20B/B
25/20A/B
25/20S/B
25/190C/A
25/190B/A
25/190A/A

kW

HP

0,37
0,55
0,55
0,75
1,1
1,1
1,5
1,5
1,8
2,2

0,5
0,75
0,75
1
1,5
1,5
2
2
2,5
3

P2
kW

HP

0,45
0,55
0,75
1,1
1,1
1,5
1,5
0,75
1,1

0,6
0,75
1
1,5
1,5
2
2
1
1,5

P2
kW

HP

0,55
0,75
1,1
1,5
2,2
3
4
2,2
3
4

0,75
1
1,5
2
3
4
5,5
3
4
5,5

P2

NM

NM
NM
NM
NM
NMM
NM
NMM
NM
NM
NM
NM

10/FE
10/DE
10/AE
10/SE
11/BE
11/BE
11/A
11/A/A
12/D/A
12/C/A
12/A/A

kW

HP

0,55
0,75
1,1
1,5
1,5
1,5
1,8
2,2
2,2
3
4

0,75
1
1,5
2
2
2
2,5
3
3
4
5,5

Q
m3/h

l/min

16
22
27
31
33,5

H
m

1,2

1,5

1,89

2,4

20

25

31,5

40

50

21,6
26,5
30,5
33
37,5
37,5
42
47
47,5
56

21,3
26
30
32,5
37,5
37,5
42
47
47,5
55,5

20,9
25,5
29
32
37
37
41,5
46,5
47
55,5

20,3
25
27,5
31,5
36,5
36,5
41
46
46,5
55

19,4
24
25,5
30,5
36
36
40,5
45,5
46
54,5

2,4

3,6

4,2

4,8

5,4

6,6

7,5

8,4

60

70

80

90

100

110

125

140

18,1
23
23,5
29,5
35
35
40
45
45,5
53,5

16,3
22
20
28,5
34
34
39
44
44,5
52,5

20
16
27
32
32
37
43
43,5
51,5

26

24

30,5
35
41,5
42
50

28,5
32
40
40,5
48

37,5
38
46

33
33,5
42

26
26,5
36

3,6

4,2

4,8

5,4

6,6

7,5

8,4

70

80

90

100

110

125

140

40
43
53,5
26,5
32

40
50
25,5
30,5

36
46
24
29

22
27

Q
m3/h

1,2

1,5

1,89

l/min

16

20

25

31,5

40

50

60

33
37
43
52
53
57,5
67

32
36
42
51,5
52,5
57
66,5

31
35
40,5
51
52
56,5
66

29
33
39
50
51
55,5
64,5
30,5
36

26,5
30,5
36,5
48,5
50
54
63
30
35,5

23
27,5
33
47
48
51,5
61,5
29,5
35

18
23
29
45
46
49
59
28,5
34,5

H
m

18
25
43,5
46
57
27,5
33,5

Q
m3/h

2,4

3,6

4,8

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18

l/min

40

50

60

80

100

110

125

140

160

180

200

220

250

280

300

20
23,5

19,9
23,4
31
36,5
42,6
50,3
57,8
60,5
75
97

19,8
23,3
30,7
36,2
42,3
50,2
57,7
59
74
96

19,3
22,9
30
35,5
41,8
49,8
57,4
55,5
70
93,5

18,5
22,1
28,5
34,5
41,1
49,3
57,2
51
66
90

18
21,7
28
34
40,7
49
57
48,5
64
88

17,3
20,9
27
33,5
40,2
48,6
56,7
44
60
84

16,3
20
26
32,5
39,6
48,1
56,4
38
54
79

15
18,7
23
31
38,6
47,3
55,8

13,2
17,1

11
15,2

28,5
37,6
46,5
55,2

26
36,3
45,5
54,3

34,7
44,3
53,3

42,1
51,2

38,9
48,2

45,6

H
m
62
76
98

46
70

Q
m3/h

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

27

30

l/min

110

125

140

160

180

200

220

250

280

315

350

400

450

500

12,5
18
23
23,5
25,5
29,5
30,1
35,5
37,5
44,5
57

12
17,5
22,5
23
25
29
29,8
35
37
44
56

11,5
17
22
22,5
24
28,5
29,4
34,5
36
43,5
55,5

11
16,5
21,5
22
23
27,5
28,8
34
35
42,5
55

10
16
21
21,5
22,5
27
28,1
33,5
33,5
41
54,5

9
15,5
20,5
21
21,5
26
27,4
33
32
40
53,5

7,5
14
19
20,5
19,5
25*
26
32*

19
17,5
22,5*
24,5
30*

18,5

16,5

13

H
m

12,5
18
23
23,5
26,5
29,5
30,2
35,5
38
45
57,5

38
51,5

36
49

NM, NMD

Close Coupled Centrifugal Pumps


with threaded ports

Performance n 2900 rpm

B-NMD

B-NMD
B-NMD
B-NMD
B-NMD
B-NMD
B-NMD
B-NMD
B-NMD

32/210D/A
32/210C/A
32/210B/A
32/210A/B
40/180D/A
40/180C/A
40/180B/A
40/180A/B

B-NM

B-NM
B-NM
B-NM
B-NM

17/HE
17/GE
17/F/A
17/D/A

P2

NMD

NMD
NMD
NMD
NMD
NMD
NMD
NMD
NMD

32/210D/A
32/210C/A
32/210B/A
32/210A/B
40/180D/A
40/180C/A
40/180B/A
40/180A/B

kW

HP

4
5,5
7,5
9,2
4
5,5
7,5
9,2

5,5
7,5
10
12,5
5,5
7,5
10
12,5

P2

NM

NM
NM
NM
NM

17/HE
17/GE
17/F/A
17/D/A

Q
m3/h

5,4

l/min

90
71
84
104
114

H
m

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

100

110

69
83
103
113

67,5
82
102
112

125

140

160

180

200

220

250

280

315

350

400

65
81
100
110
60
69
87
94

62,5
79
98
108
59,5
68
86
93

58
76
95
105
57
67
85
92

53
73
92
103
56
66
84
91

46
69
88
99
53
64,5
82,5
89,5

37*
64*
84*
96*
51,5
63
81
88

54*
76*
90*
48
60
78
85

44
57
75
82

39
53
71
78

34*
48*
66*
74*

25*
40*
59*
67*

Q
m3/h

21

24

27

30

33

37,8

42

48

54

60

66

75

84

96

350

400

450

500

550

630

700

800

900

1000

1100

1250

1400

1600

9,5
12

9,2
11,7
16

9
11,5
16
18

8,6
11,2
15,5
18

8,2
11
15
17,5

7,5
10,3
14,5
17

6,7
9,7
14
16,5

5,5
8,5
13
15,5

3,5*
7*
11,5*
14*

4*
10*
13*

8*
11,5*

kW

HP

l/min

1,1
1,5
2,2
3

1,5
2
3
4

H
m

NM, NMD
Standard construction.
B-NM, B-NMD Bronze construction.

6,6

P2 Rated motor power output.


H Total head in m.

With single-phase motor = NMM - NMDM.


Maximum suction lift 1-2 m.
Tolerances according to UNI EN ISO 9906:2012

Rated currents
P1

* NMM 25/12B/A
* NMM 10/FE
* NMM 25/12A/A
* NMm 10/DE

P2

kW

kW

HP

230 V
1~
IN A

0,62
0,72
1
0,9
0,9
1,3
1,2
1,2
1,6
2
2,5

0,37
0,45
0,55
0,55
0,55
0,75
0,75
0,75
1,1
1,5
1,8

0,5
0,6
0,75
0,75
0,75
1
1
1
1,5
2
2,5

3
3,6
4,5
4,2
4,2
6
5,4
5,8
7,4
9,2
11,2

P2
IA/IN

kW

HP

2,7
2,9
2,3
2,5
2,5
3
3,3
2,6
3
3,8
4,5

0,37
0,45
0,55
0,55
0,55
0,75
0,75
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2

0,5
0,6
0,75
0,75
0,75
1
1
1
1,5
2
3
4
5,5
7,5
10
12,5

* NM 25/12B/A
* NM 10/FE
* NM 25/12A/A
* NM 10/DE

Maximum power input.


P1
Rated motor power output.
P2
IA/IN D.O.L. starting current / Nominal current

230 V / 400 V Y
400 V / 690 V Y
IN A
IN A
IN A

IA/IN

1,3
1,3
1,7
1,6
2,3
2,2
2
2,3
2,7
4,3
5,3
6,6
9,6
10,9
14,3
18,5

3,8
3,5
3,6
3,9
4,8
4
4,3
4,8
5,6
5,5
7,4
8,2
7,6
9,1
9,1
8,2

2,3
2,3
3
2,8
4
3,7
3,5
4
4,6
7,5
9,15
11,5

5,5
6,3
8,3
10,7

NM

Close Coupled Centrifugal Pumps


with threaded ports

Characteristic curves n 2900 rpm


0 U.S. g.p.m.

10

15

20

40

NM 1/A

0 U.S. g.p.m.

10

25

35

40 42
43

30
35

70
H ft

40
20

44
46

100

44
45%

B 143

Hm

30

120

NM 2

80

A 130

30

90

A 158

Hm

20

44
80

60

47%

20
60

50

15

40
0
0

/h
Qm
l/min

l/s

2
20

0.2

30

40

0.4

0.6

3
50

4
60

0.8

5
70

40
10

80

1.2

0.6

0
0

m /h
Q l/min

l/s

3
50

0.5

6
100

1.5

1.9

1.0

0.7

0.5

P kW

0.4

1.0
P HP

P kW

0.5

P HP

10

H ft

30

0.5

0.5

0.3
0.3

1
1

Q m 3/h

0 U.S. g.p.m.

10

72.047

15

4
10
2
0

20

60

Q m 3/h 1

0 U.S. g.p.m.

50

36

Hm

Hm

80

20

40

72.048

30

38

180
160

39%
38

140
34

C 171

120

34
32

60

30

1~

30

100
30

3~

80

40
0
m 3/h
Q
0 l/min
0

l/s

2
20

0.2

30

40

0.4

0.6

3
50
0.8

4
60

70

20

5
80

1.2

1.0

l/s

l/min

3
50

0.5

6
100

1.5

8
2

P kW

0.5

A
3
B 3~
B 1~
C 3~

C 1~

1
0

2
5

NPSH ft

10

NPSH m

9
150
2.4

2
P HP

P kW

0.5

NPSH m

Q m /h

2.6
1.0

1
0

0
0

P HP

20

10

38

NM 3

34

B 3~ 191
B 1~ 181

36
38%

10

A 1~ 191

100

H ft

30 32
34

30

S 155
30

A 3~ 202

120

NM 2/S

Q m 3/h

72.050

10
2
0

10

15

5
0

Q m 3/h

72.049/1

NPSH ft

40

20

NPSH ft

NPSH m

10

15

0.0

NPSH ft

NPSH m

H ft

0.2

NM

Close Coupled Centrifugal Pumps


with threaded ports

Characteristic curves n 2900 rpm

1
30

25

A 131.5

40

50 54

110

39

100

43%

Hm

41

B 152
30

30

40

50

90

120

37

35

20

NM 25/12

NM 20/160

A 161.5

80
58

60

B 121

62

70

20

64
66

90
25

60
60
50

70%

15

80

62

43

40

70

Q m /h 1

l/s

l/min 20

3
40

0.4

0.6

60
0.8

6
100

80

1.2

1.4

1.6

7
1.8

1.2

P kW

1.0

1.6

1.0

1.4

0.8

1.2

0.8

1.0

0.6

l/s

6
100

10

12
200

150

3
1.2

1.0

0.8
0.6
0.4
0.2

Q m3/h 1

0 U.S. g.p.m.

20

30

72.005

40

50

NPSH ft

8
2

10
2

130

60

15

5
0

Q m3/h 2

0 U.S. g.p.m.

60

20

40

35

72.006/N

12

60

NM 25/20

120

50

10

S 200

NM 25/160
45

NPSH ft

NPSH m

180

A 190

53

50

100

55

30

160

Hm

110

55

B 150

H ft

NPSH m

50

0.2

0.6

A 161.5

Hm

l/min

0.4

40

3
Q m /h 2

0.6

0.8

0.4

0
0

P kW

0
0

10

P HP

20

B 178

140

H ft

Hm

30

130

0 U.S. g.p.m.10

H ft

20

P HP

10

H ft

40

0 U.S. g.p.m.

40

90

120
57%

80
30

70
3

0
0

Q m /h 2

l/s

l/min

4
50

6
100

10

12
200

150
2

14

3.8

1.6

0.4
5

16

0
10

12

NPSH m

4
3

2
1

10

12

250

72.007

14

300

B
2
0

60

(%)

0.6

200

40
20

NPSH m

0.8

150

0
80

P HP

P kW

1.0

Q m3/h 2

100

15

NPSH ft

l/min 50

10

2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6

1.4
1.2

Q m /h

P kW

20

100
0

P HP

56

20

6
4

10

2
0

11

30

S
0

Q m3/h

10

15

72.008

NPSH ft

25

NM

Close Coupled Centrifugal Pumps


with threaded ports

Characteristic curves n 2900 rpm


0 U.S. g.p.m.

40

S 130

60

100

70

72%

0 U.S. g.p.m.

20

30

40

A 164

NM 10

50

50

35

55

68

D 118

30
H ft

50

F 103

120

NM 11
61
63%

100

B 3~ 149
B 1~ 143

Hm

65
15

70

A 1~ 149

60

66

60

57 59

70

20

Hm

38

80

60 65
66 68

A 130

80

H ft

25

25

80

40
10

20

30

60
20
10

15

100
1

20

200
2

15

25
400

300
6

1.6

1.6

1.2

0.8

0.8
0.4

300

A 3~ 3
B 3~
A 1~
B 1~ 2

1.0
1

0.4

4
10

NPSH m

20

NPSH ft

NPSH m

15
200

2.0

25

20
15

10

60

10
100

0.4

l/s

l/min

P kW

P kW

Q m /h

2.4

S 2.0

1.2

0
0

2
0

Q m3/h

0 U.S. g.p.m.

10

20

15

30

40
40

A 204

20

50
45

72.052

60

25

70

20

5
0

49

51

NM 12

0 U.S. g.p.m.

10

100

52

150
65

70

72

F 120

180

200

74

250

300

50

75
74

G 107

160

Hm

H ft

60

NM 17

75

76%

C 187

72.053

15

15

53%

50

Hm

Q m3/h

D 125
47

P HP

l/s

l/min

NPSH ft

Q m /h

72

40

H 100

10

30

140

H ft

0
0

P HP

D 178

40

20
5

120

10
100
3

0
0

Q m /h

l/s

10
100

l/min
1

200
2

15
3

300

0
0

Q m /h 10

20

l/min 200

l/s

30
400

40
600

50
800

10

60
1000
15

P kW

P HP

P kW

5
3

18

70

P HP

30

1
2

NPSH m

15

4
10
2

Q m3/h

10

15

72.054

NPSH ft

NPSH m

15

4
10

3
2

12

Q m3/h 10

20

30

40

50

60

72.057

70

NPSH ft

NMD

Close Coupled Centrifugal Pumps


with threaded ports

Characteristic curves n 2900 rpm


5

10

15

25

NMD 20/140
60

35

37

200

40

A 1~ 147-147
B 3~ 143-143

38,5%
38
37

100

50

41%
H ft

38

Hm

37

30

20

150

30

Z 124-124

10

35

B 118-118

Hm

0 U.S. g.p.m. 5
70
A 3~ 158-158

20

NMD 20/110

A 130-130
40

15

H ft

0 U.S. g.p.m.
50

B 1~ 143-143
150
40

20

40
50

20

l/min

l/s

0.2

30

3
50

40

0.4

0.6

4
60

0.8

70

30
0
0

5
80

1.2

3
Q m /h 1

l/min

l/s 0.2

2
20
0.4

3
40

0.6

4
60

0.8

80

1.2

1.4

0.8

1.5

0.6

0.4

2.5

A 1~

P kW

0.6

P HP

P kW

1.0

1.6

A 3~

1.2

0.8

100
6
100

2.0

B
1.5

1.0

0.4

1.0

NPSH ft

10

NPSH m

0.6

NPSH m

0.2

1
0

110

Q m3/h

0 U.S. g.p.m. 10

20

A 190-190

100

30

35 37

NMD 25/190
300
40,5%

B 172-172
H ft

40
70

C 156-164
200

60
35

50
40

0
0

Q m /h

l/s

l/min

6
100

50
0.5

1.5

100
10

8
150
2

2.5

P kW

B 5

P HP

30

2
1
5

15

4
10

3
2

1
0

Q m3/h

72.009

10

NPSH ft

NPSH m

2
5
0

40

40

80

Hm

72.001

30

90

10

1
0

P HP

0
1.0

Q m /h

13

Q m3/h 1

72.003

NPSH ft

10
0
0

NMD

Close Coupled Centrifugal Pumps


with threaded ports

Characteristic curves n 2900 rpm


20

40
35

A 208-208

38

60

40

B 200-200

42

100

NMD 32/210

40

A 184-184

60

45

80

50

B 178-178

350

43

100

0 U.S. g.p.m.20

55

44

Hm

D 176-176

80

250

57

300

57.5%

C 168-156

57

D 156-156

56

200

50

200

60

NMD 40/180
56

57.5

75

300

45%

Hm

C 194-172

100

H ft

0 U.S. g.p.m.

H ft

120

150
100

40
3

0
0

Q m /h

l/s

l/min 50

10
100

150

15
250

200

25

300

0
0

Q m /h

l/s

10

15

100
1

200
2

20
300

400

10
2

10

15

72.013

NPSH ft

NPSH m

Q m3/h

2
0

4
2
0
15

4
10

3
2

14

8
6

15

10

P HP

6
4

12

Q m3/h

10

15

20

72.029

NPSH ft

P kW

10

P HP

P kW

12

A
B

NPSH m

l/min

10

10

NM

Close Coupled Centrifugal Pumps


with threaded ports

Dimensions and weights

1
TYPE
NM 1/AE
NM 2/B/A
NM 2/S/A
NM 2/A/A
NM 3/CE
NM 3/BE
NM 3/A/A
B- NM 20/160BE
B- NM 20/160AE
B- NM 25/12B/A
B- NM 25/12A/A
B- NM 25/160BE
B- NM 25/160AE
NM 25/20B/B
NM 25/20A/B
NM 25/20S/B
B- NM 25/200B/B
B- NM 25/200A/B
B- NM 25/200S/B
NM 10/FE
NM 10/DE
NM 10/AE
NM 10/SE
NM 11/BE
NM 11/A/A
NM 12/D/A
NM 12/C/A
NM 12/A/A
B- NM 17/HE
B- NM 17/GE
B- NM 17/F/A
B- NM 17/D/A

(NMM 3/A/A)
131 (NMM
11/A)

fM
a

l1
DN2

l2

DN2

DN1

h2
H
g1 h1
4.93.098

m2

n3

m1

n2
w

B-NM

B-NM 20/160AE-BE
B-NM 25/12A/A-B/A
B-NM 25/160AE-BE

NM

B-NM

kg

kg

kg

8,7
14
14,2
15,1
24
26
30,4
19,9
20,7
13,2
14,2
20,4
22,5

8,6
13,1
13,3
14,2
22,9
25,1
29,1
18,4
19,7
12,3
13,3
19,7
21,5
31,6
40,9
42,2

21
22,5
13,5
14,5
22,8
24

35,7
43,7
45,2
19,3
19,4
20,2
22,1
24,7

18,5
18,8
19,3
21,5
24,1
28,1
33,5
42
43,5
22,2
23,2
28,2
36,2

23
24,2

29,2
30,2
35,2
43,2

n1

NM
NM 1/AE
NM 2/A/A-S/A-B/A
NM 3/ BE-CE
NM 3/A/A
NM 20/160AE-BE
NM 25/12A/A-B/A
NM 25/160AE-BE
NM 25/20B/B
NM 25/20A/B-S/B

B-NM 25/200B/B
B-NM 25/200A/B-S/B

B-NM 17/ GE-HE


B-NM 17F/A
B-NM 17/D/A

NMM

NM 10/SE-AE-DE-FE
NM 11/ BE
NM 11/A/A
NM 12/D/A
NM 12/A/A-C/A
NM 17/ GE-HE
NM 17/F/A
NM 17/D/A

mm

DN2
DN1
ISO 228

fM

h1

h2

m1

m2

n1

n2

n3

l1

l2

G1
G1

G1
G1

40
45

80
95

132
150

176
207

40
40

32
32

170
190

140
160

17
17

35
35

9,5
9,5

77
87

81
90

G1

G1

50

112

180

240

55

43

245

205

37

45

11,5

110

113

G 11/4
G 11/2
G 11/2

G 3/4
G1
G1

53
56
56

100
90
100

150
140
160

150
130
150

38
38
38

9,5
9,5
9,5

102
85
102

102
88
102

G1

63

125

180

228
199
228
253
263

190
170
190

G 11/2

45

11,5

125

125

G 11/2

G1

63

125

180

253
263

45

11,5

125

125

G2

G 11/4

63

50

13

90

97

G2

G 11/4

70

50

15

103

110

G2

G 11/4

70

50

15

125

127

G 21/2

G 21/2

80

261
305
375
415
375
313
380
433
460
445
460
382
400
440
440
470
417
463
480

50

14

96

113

171
203
244
284
246
195
246
291
295
303
295
239
247
287
287
300
257
304
295

37,5 27,5
37,5 27,5
37,5 27,5

100

150

228

50

35

190

140

30
9
30
49
42
49
42
30

112

170

240

50

35

210

160

37

132

190

260
270

50

35

240

190

112

160

50

35

210

160

45

32,5

245

200

45

32,5

245

200

240

15

240
250

47
45
37
37
20

g1
10
10
12
10
10
10
11
11
14
14
14
14

NMD

Close Coupled Centrifugal Pumps


with threaded ports

Dimensions and weights


NMD 20/140
NMD 25/190

NMD 20/110

fM
a

l1

l2

325
93

4.93.179

36
46
8.5

4.93.005

17

9.5

38
130
170

188

m2

n3

TYPE

NMDM
kg

NMD
kg

B-NMD
kg

B- NMD 20/110B/A
B- NMD 20/110Z/A
B- NMD 20/110A/A

13
14
15,1

12,1
13
14,2

13,4
14,2
17,4

NMD
NMD 20/140AE-BE
NMD 25/190C/A
NMD 25/190A/A-B/A

B- NMD 20/140AE-BE
B- NMD 25/190C/A
B- NMD 25/190A/A-B/A

n1

TYPE
BBBBB-

n2

m1
w

B-NMD

h1

g1

10
95

DN1

204

132

G 1 1/4

G1

DN2

h2

93
G1

75

DN2

NMD 20/140BE
NMD 20/140AE
NMD 25/190C/A
NMD 25/190B/A
NMD 25/190A/A

NMDM
kg

NMD
kg

B-NMD
kg

23,9
25,2

22,7
24,8
42
49,7
51,5

25,2
27,6
45,7
54
55,5

mm

DN2
DN1
ISO 228

fM

h1

h2

m1

m2

n1

n2

n3

l1

l2

g1

G 11/4

G1

80

112

152

55

200

160

9,5

110

110

140

180

100

70

240

190

50

14

133

133

256
314
306

10

97

37
50
49

38

G1

243
268
278

75

11/2

417
487
500

13

NMD 32/210
NMD 40/180
fM
a

l1

l2

DN2

DN2

TYPE

NMD
kg

B-NMD
kg

B- NMD 32/210D/A
B- NMD 32/210C/A
B- NMD 32/210B/A
B- NMD 32/210A/B
B- NMD 40/180D/A
B- NMD 40/180C/A
B- NMD 40/180B/A
B- NMD 40/180A/B

60,5
71
77
99
59,5
70
76
97

66,5
77
82,5
105
65,5
76
81,5
102

DN1

h2
H
g2

h1

4.93.077

b1

s1
w

m5

w1

n4

m4

B-NMD
B- NMD 32/210D/A
B- NMD 32/210B/A -C/A
B- NMD 32/210A/B
B- NMD 40/180D/A
B- NMD 40/180B/A -C/A
B- NMD 40/180A/B

g2*

n5

NMD
NMD 32/210D/A
NMD 32/210B/A -C/A
NMD 32/210A/B
NMD 40/180D/A
NMD 40/180B/A -C/A
NMD 40/180A/B

DN1
DN2
ISO 228
G2

G 11/4

G2

G 11/2

mm
a

fM

530
110 550
625
535
121 555
630

16

h1

h2

m4

m5

n4

n5

293 205 175 194


155
150 215 310 280 250 258
355 298 268 286
170
293 205 175 194
155
150 215 310 280 250 258
355 298 268 286
170

140
0
190
0
216
6
140
0
190
0
216
6

w1
15

15

b1

s1

54
68
70
54
68
70

10
12
12
10
12
12

l1

l2

139
150 150 108
152
133
145 145 102
145

g2
6*
38
38
6*
38
38*

NM

Close Coupled Centrifugal Pumps


with threaded ports

Features

4.93.322

Compact Design
The compact design allows for easy installtion even in confined spaces.

Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid are
dimensioned to guarantee the maximum resistence to mechanical stress.

A unique design
The lantern bracket design prevents contact with the pumps rotating parts, providing
protection to the end user whilst allowing for inspection of the mechanical seal.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing
high reliability under all operating conditions.

17

NMD

Close Coupled Centrifugal Pumps


with threaded ports

Features

3.94.044

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NMD series pumps to be selected
for use with different types of liquids.

Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid
are dimensioned to guarantee the maximum resistence to mechanical stress.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing
high reliability under all operating conditions.

18

09/2016

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Construction
Close-coupled centrifugal pumps; electric motor with extended
shaft directly connected to the pump up to 22 kW, new bracket
construction for standard motors (stub-shaft construction) from 30
to 75 kW with integrated thrust bearing.
Pump casing with axial suction and radial delivery on top, main
dimensions and performance according to EN 733.
NM(S): version with pump casing and lantern bracket in cast iron.
B-NM(S): version with pump casing and lantern bracket/casing
cover in bronze. (the pumps are supplied fully painted).
Connections: Flanges according to PN 10, EN 1092-2.
Counter-flanges (on request)
Sizes
from NM 32/.. to NM 50/...
from NM 65/.. to NMS 100/...

Flanges
Screwed flanges EN 1092-1, PN 16
Flanges for welding EN 1092-1, PN 10

Version with frequency converter (on request)

Applications
For clean liquids without abrasives, which are non-aggressive for
the pump materials (solids content up to 0,2%). For water supply.
For heating, air conditioning, cooling and circulation plants.
For civil and industrial applications.
For fire fighting applications. For irrigation.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar (16 bar for
NM 65/12, NM 65/16 and NM 80/16).
Continuous duty.

The electropumps NM, B-NM, NMS, B-NMS series comply with the European
Regulation no. 547/2012.

Motor

Materials
Components
Pump casing
Lantern bracket NM
Casing cover for NMS
Lantern bracket NMS
Impeller

NM, NMS

B-NM, B-NMS

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

2-pole induction motor, 50 Hz (n 2900 rpm).


NM, NMS: three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% from 4 to 75 kW.
Insulation class F.
Protection IP 54 (IP 55 for NMS).
Motor suitable for operation with frequency converter from 2,2 kW.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from 7,5 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.

Cast iron GJL 200 EN 1561


Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
for NM 32/12-16-20, NM 40/20, B-NM 32/125-160-200, B-NM 40/200
AISI 303 up to 2.2 kW
Cr Ni Mo steel
AISI 430 from 3 kW to 75 kW
AISI 316

Shaft
Mechanical seal
Counter-flanges

Special features on request


- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Protection IP55.- Special mechanical seal.
- Packed gland (only for NM standard construction).
- Single-phase motor (NMM) up to 1,5 kW.
- Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 1,5 kW.

Carbon - Ceramic - NBR


Steel Fe 430B UNI 7070

Coverage chart n 2900 rpm


30

40

50

U.S. g.p.m.

100

200

300

400

500

1000

2000

130

400

100

300

H
m

NM(S) 65/250

NM 40/25

NM 50/25

NM 32/20

NM 40/20

NM 50/20

NM 65/200

NM 32/16

NM 40/16

NM 50/16

NM 65/16

NM(S) 80/250 NMS 100/250

200

50
40

ft

NM(S)
80/200
NM(S) 100/200

30

100
90
80
70
60

NM 80/16
20
NM 32/12

NM 65/12

NM 40/12

50

NM 50/12

40
10

30

20
5

6
100

9 10
150

m 3/h

Q l/min

20
300

30
400

500

40

50

200

100
1000

2000

3000

300
4000 5000

400

500
8000

72 821 C

19

NM EI

Close Coupled Centrifugal Pumps


with flanged connections

Pumps with frequency converter


The NM EI pumps are available with power from 0,55 kW up to 11 kW, the pumps are equipped with I-MAT installed
on board which allows to realize a variable-speed system extremely compact and efficient, ideal in applications of water
supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,55 kW to 11 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases

Operating modes
H

Constant pressure mode


with pressure transducer

+
-

In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H

Proportional pressure mode


with pressure transducer

+
-

In this mode the system changes the working pressure according to the required
flow rate.

Constant flow mode


with flow meter
In this mode the system maintains a constant flow rate value in a point of the installation according to the required pressure.

Fixed speed mode


with setting of the speed preferential rotation.
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range.

H
max

+
min

Constant temperature mode


with temperature transducer
In this mode the system keeps the temperature constant inside a system by changing the speed of the pump.
20

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Performance n 2900 rpm


B-NM

B-NM 32/12F
B-NM 32/12D
B-NM 32/12A
B-NM 32/12S
B-NM 32/16B
B-NM 32/16A/A
B-NM 32/20D/A
B-NM 32/20C/A
B-NM 32/20A/A

B-NM

NM

NM 32/12FE
NM 32/12DE
NM 32/12AE
NM 32/12SE
NM 32/16BE
NM 32/16A/A
NM 32/20D/A
NM 32/20C/A
NM 32/20A/A

B-NM 40/200A/A
B-NM 4025/C/C
B-NM 4025/B/C
B-NM 4025/A/C

B-NM

NM

B-NM 50/12F/A
B-NM 50/12D/A
B-NM 50/12A/A
B-NM 50/12S/A
B-NM 50/160B/B
B-NM 50/160A/B
B-NM 50/200B/C
B-NM 50/200A/C
B-NM 50/200S/C
B-NM 5025/C/C
B-NM 5025/B/C
B-NM 5025/A/C

NM 50/12F/B
NM 50/12D/B
NM 50/12A/B
NM 50/12S/B
NM 50/16B/B
NM 50/16A/B
NM 50/20B/C
NM 50/20A/C
NM 50/20S/C
NM 50/25C/C
NM 50/25B/C
NM 50/25A/C

B-NM - B-NMS

NM - NMS

B-NM 65/125C/B
B-NM 65/125A/B
B-NM 65/160D/B
B-NM 65/160C/C
B-NM 65/160B/C
B-NM 65/160AR
B-NM 65/160A/C
B-NM 65/200C/B
B-NM 65/200B/B
B-NM 65/200A/B
B-NM 65/250C/B
B-NMS 65/250B/A
B-NMS 65/250A

kW

HP

0,55
0,75
1,1
1,5
1,5
2,2
2,2
3
4

0,75
1
1,5
2
2
3
3
4
5,5

P2

NM

NM 40/12F/A
NM 40/12C/A
NM 40/12A/B
NM 40/16C/B
NM 40/16B/B
NM 40/16A/B
NM 40/20D/A
NM 40/20C/A
NM 40/20B/A
NM 40/20AR/A
NM 40/20A/A
NM 40/25C/C
NM 40/25B/C
NM 40/25A/C

B-NM 40/12F
B-NM 40/12C
B-NM 40/12A/A
B-NM 40/16C/A
B-NM 40/16B/A
B-NM 40/16A/A
B-NM 40/20D/A
B-NM 40/20C/A
B-NM 40/200B/A

P2

NM 65/12E/B
NM 65/12C/B
NM 65/12A/B
NM 65/16D/B
NM 65/16C/C
NM 65/16B/C
NM 65/16AR
NM 65/16A/C
NM 65/20C/B
NM 65/20B/B
NM 65/20A
NM 65/25C
NMS 65/250B
NMS 65/250A

kW

HP

1,1
1,5
2,2
2,2
3
4
4
4
5,5
5,5
7,5
9,2
11
15

1,5
2
3
3
4
5,5
5,5
5,5
7,5
7,5
10
12,5
15
20

P2
kW

HP

2,2
3
4
4
5,5
7,5
9,2
11
15
11
15
18,5

3
4
5,5
5,5
7,5
10
12,5
15
20
15
20
25

Q
m3/h

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

27

30

l/min

110

125

140

160

180

200

220

250

280

315

350

400

450

500

12,5
18
23
23,5
29,5
35,5
38
45
57,5

12,5
18
23
23,5
29,5
35,5
37,5
44,5
57

12
17,5
22,5
23
29
35
37
44
56

11,5
17
22
22,5
28,5
34,5
36
43,5
55,5

11
16,5
21,5
22
27,5
34
35
42,5
55

10
16
21
21,5
27
33,5
33,5
41
54,5

9
15,5
20,5
21
26
33
32
40
53,5

7,5
14
19
20,5
25*
32*

19
22,5*
30*

18,5

16,5

13

38
51,5

36
49

Q
m3/h

15

16,8

18,9

21

24

27

30

33

37,8

39

42

45

48

54

l/min

250

280

315

350

400

450

500

550

630

650

700

750

800

900

14
17,5
22
23
29
37
39
41,5
50
55
57,5
61
69,5
90

13,5
17
22
22,5
28,8
36,5
38
40,5
49,5
54,5
57
61
69,5
90

13
16,5
21,5
22
28
36,5
37
39,5
48,5
54
56,5
60,5
69
89,5

12
16
21
21,5
27,5
36
35,5
38
47,5
53
55,5
59,5
68,5
89

11
15
20
20
26,5
35
33,5
36
45,5
51
54,5
58,5
67
88,5

9,5
13,5
19
18,5
25
33,5
30,5
33,5
43,5
49
52,5
56,5
65,5
87

8
12
18
16,5
23,5
32
27

6
10,5
16,5
14,5
21,5
30,5
22,5

7,5
14
11
18
27
14

6,5
13
10
17
26

11,5
16,5
14
23,5

41,5

37,5

30,5

50,5
53,5
63,5
85

48
49,5
60,5
83

42,5
41,5
53,5
77,5

40,5
40
51
76

35
33,5
45
70,5

60

66

H
m

H
m

kW

HP

4
5,5
7,5
7,5
9,2
11
15
15
15
18,5
22
22
30
37

5,5
7,5
10
10
12,5
15
20
20
20
25
30
30
40
50

20

17

Q
m3/h

24

27

30

33

37,8

42

48

54

l/min

400

450

500

550

630

700

800

900

1000 1100 1150 1200 1250 1300 1350 1400

48
55
60
55
69
80,5

47,5
55
60
54,5
68,5
80,5

15,5
20
24
26,5
31
38,5
47,5
54,5
59,5
54
68
80

15
19,5
24
26
30,5
38
47
54,5
59,5
53
67,5
79,5

14
18,5
23
25,5
29,5
37,5
45,5
53,5
58,5
51,5
66
78,5

13,5
18
22,5
24,5
28
36,5
44,5
52
57,5
49,5
64
77

12
16,5
21
23,5
26
34,5
42,5
50
55,5
46
61
74,5

10
14,5
19,5
22
24
32,5
40
48
53,5
41,5
57
71,5

8
13
17,5
20
21,5
30
37
45
50,5
35,5
52,5
67

37,8

42

66

75

84

96

108

120

132

150

168

1800

2000

2200

2500

2800

11,8
17,6
16,3
20,7
25,7
30,0
34,2
31
39
45,5

17,7
23,0
27,5
31,7
27*
35*
41,5*

H
m

Q
m3/h

P2

13

l/min

H
m

48

54

60

6
10,5
15
18
19
27
33
41,5
47
28,5
46,5
61,5

69

9
14
16,5
17,5
25,5
30,5
39,5
45
24,5
43
58,5

72

8
12,5
15,5
15,5
24
28
37
43

630

700

800

900

1000

1100

1250

1400

1600

16,5
21,1
25,9

16,4
21
25,8

16,2
20,8
25,6
24,3
28,1
32,6
36,4
40,5
44
50
56,5
64
79,5
90

15,9
20,6
25,4
24,1
28,0
32,5
36,3
40,4
43,5
49,5
56
63,5
79
89,5

15,5
20,3
25,1
23,9
27,8
32,3
36,2
40,2
43
49
55,5
63
78,5
89

15,1
19,9
24,8
23,6
27,6
32
35,9
40
42,5
48,5
55
61,5
78
88,5

14,3
19,1
24,1
23,1
27,1
31,5
35,5
39,5
41
47,5
54,5
60
77
87,5

13,2
18,2
23,3
22,3
26,3
30,8
34,8
38,8
39,5
46,5
53,5
57,5
75
86

11,4
9,2
16,5 14,4
21,9
20
20,8 18,8
24,9 23,1
29,5 27,9
33,7 32,1
37,6 36,1
37,5
35
44,5
42
51
48,5
54,5* 50*
72*
67*
83,5* 78,5*

21

75

78

11,5
14
13,5
22,5
25,5
35
40,5

10
13
11,5
20,5
23
32,5
37

81

84

11
9,5
19

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Performance n 2900 rpm


B-NM - B-NMS

P2

NM - NMS

B-NM 80/160E/B
B-NM 80/160D/C
B-NM 80/160C/C
B-NM 80/160B/C
B-NM 80/160A/C
B-NMS 80/200B/A
B-NMS 80/200A/A
B-NMS 80/250E/A
B-NMS 80/250D/A
B-NMS 80/250C/A
B-NMS 80/250B/A
B-NMS 80/250A/A
B-NMS 100/200E/A
B-NMS 100/200D/A
B-NMS 100/200C/A
B-NMS 100/200B/A
B-NMS 100/200A/A
B-NMS 100/250B/A
B-NMS 100/250A/A

NM 80/16E/B
NM 80/16D/C
NM 80/16C/C
NM 80/16B/C
NM 80/16A/C
NM 80/20B
NMS 80/200A
NM 80/25E
NMS 80/250D
NMS 80/250C/A
NMS 80/250B/A
NMS 80/250A/A
NM 100/200E/B
NM 100/20D
NMS 100/200C
NMS 100/200B/A
NMS 100/200A/A
NMS 100/250B/A
NMS 100/250A/A

kW

HP

7,5
9,2
11
15
18,5
22
30
22
30
37
45
55
18,5
22
30
37
45
55
75

10
12,5
15
20
25
30
40
30
40
50
60
75
25
30
40
50
60
75
100

NM(S) Standard construction.


B-NM(S) Bronze construction.

Q
m3/h

75

84

96

108

120

132

150

168

180

192

210

240

270

300

l/min

1250

1400

1600

1800

2000

2200

2500

2800

3000

3200

3500

4000

4500

5000

21,5
25,2
28,7
34,8
39,9
46,5
56
51
65
73,5
84
95

20,9
24,5
28,2
34,5
39,6
46
55,5
50
64
73
83,5
94,5

19,9
23,5
27,4
33,8
39
45,5
55
48,5
62,5
72
82,5
93,5

18,7
22,4
26,4
33
38,2
44,5
54
46,5
61
70,5
81,5
92,5
30
36
45
54
61,5
73,5
91

17,4
21,1
25,1
32,1
37,4
43,5
53
44,5
59
69
80
91,5
29,5
35,5
44,5
53,5
61
73
90,5

15,9
19,6
23,8
30,9
36,4
42
52
42
56,5
67
78
90
29
35
44
53
60,5
72,5
90

13,4
17,2
21,3
28,9
34,5
39*
49,5*
38*
53*
63*
74,5*
87,5*
28
34
43,5
52,5
60
71,5
89,5

10,6
14,4
18,5 16,4
26,4 24,5
32,2 30,3
35,5* 32*
43*
46*
29*
33*
49* 45,5*
59* 55,5*
70,5* 67*
84* 80,5*
26
27
32
33
42,5 41,5
51,5 50,5
59,5 58,5
68,5
70
88
88,5

23
29
39
48
56,5
65
85

19*
24,5*
34,5*
44*
53*
61*
81*

19*
29*
38,5*
48*
55,5*
75*

22
32
42
48,5
67

H
m

P2 Rated motor power output.


H Total head in m.

22,4
28,1

41*
51,5*
63*
76,5*
25
31
40,5
49,5
58
67
87

Maximum suction lift 1-2 m.

With 1 m suction head.


Tolerances according to UNI EN ISO 9906:2012

Rated currents
P2
kW
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
75

HP
0,75
1
1,5
2
3
4
5,5
7,5
10
12,5
15
20
25
30
40
50
60
75
100

230V / 400V Y
400V / 690V Y
IN A
IN A
IN A
4
2,3
4
2,3
4,6
2,7
7,5
4,3
9,2
5,3
11,5
6,6
9,6
5,5
10,8
6,2
14,3
8,3
18,5
10,7
21,5
12,4
27,3
15,8
34
19,6
41
23,7
54
31,2
64
36,9
77
44,5
93
53,7
128
73,9

IA/IN
4,8
4,8
5,6
5,5
7,4
8,2
7,6
9,1
9,1
8,2
8,5
9,5
9,4
10,7
8,8
7,2
7,3
6,8
7

P2
Rated motor power output.
IA/IN D.O.L. starting current / Nominal current

22

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Characteristic curves n 2900 rpm


0 U.S. g.p.m.20
S 130

40

60

80

70

72%

20

0 U.S. g.p.m.

20

30

40

A 164

NM 32/12

50

35

50

60

70
120

NM 32/16

55

57 59

70

70

61
63%

68

D 118

60

66

50

F 103

B 1~ 143

Hm

65

15

100

B 3~ 149

30
H ft

Hm

38

80

60 65
66 68

A 130

100

H ft

25

25

80

40
10

20

30

60
20

15

25
400

0
2.4

S 2.0

1.2

P kW

1.2

0.8

0.8

0.4

l/s

15

200
2

300

4
10
2

B 3~
B 1~ 2

25

20
15

10
2

0 U.S. g.p.m.

10

20

15

30

A 204

40
40

45

20

50

60

47

NM 32/20
49

25

70

25
25

52

Q m3/h

U.S. g.p.m.
g.p.m.
00 U.S.

10

50 40

15

60 100 80

100
150

120

A 134
68

70%

C 123

15

H ft

H
Hmm

C 187
140

15
10

66
62

F 112

40
20
10
30

3
0
10
20
30
Q m /h
l/min
200
400
50
3
2,5 0
5
10
15
20
Q m /h
200
300
l/min 100
20

100

l/s

10

15

100

l/min
1

200
2

300

P kW

Q m /h

5
6

(%)

Q m3/h

10

15

72.012

30
A
500
C
8

1
3.0

2.5
0

C
AF

2.0
1.5

40
0.5

NPSH
NPSHmm

NPSH ft

NPSH m

15

4
10

1
2.5
0,5
2.0
0
80
1.5

1.0
0.5

200
0
54

1
5

l/s 1

600
25
400

60
1.0

1,5 0

0
50 20
800
35
3

40

P kW

P HP

P kW

40
50
30

5
10

120

0
0

70
70
60

60
50

68

F 115

D 178

40

140
200

NM40/12
40/12
NM

C 122
160

80
80

A 134

20
20

53%

50

Hm

62 66

180

51

5
72.011

0
F

43
3
2
2

10
10
5

11
00
00

23

Q m3/h

P HP

72.010

0.4

NPSH m

20

30

NPSH ft

NPSH m

10
100

1.0

60

l/min

0.4

Q m /h

2.0

1.6

0
0

P HP

20
300

NPSH ft

15
200

P HP

l/s

10
100

H ftH ft

l/min

Q m 3/h
Q m3/h 5

10

10

2015

2030

25

40 30

72.014

00
50
35

NPSH
NPSH ftft

0
1.6

Q m /h

P kW

0
0

P HP

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Characteristic curves n 2900 rpm

B 151

25

C 137

20
15
10
5

m3/h 10
200
l/min

20

30
400

40

50
800

600

B
C

2
1
0
80

D 180
100

30
20
10
0

0
0

10

m3/h 10
200
l/min

20

30

40

400

600

12
10
8
6
4
2
0

B
D

50
800

AR

0
80
AR

60

(%)

40

20
0
8

NPSH ft

10
2
0
0

Q m3/h

0 U.S. g.p.m.

10

20

50

30

100

40

50

150

NPSH m

A 251

10

20

100

30

150

200

40

250

50

300

350

30
S 151

300

NM 40/25

90

NM 50/12

A 146

80

250

B 227

60

200

40

40
10

100

30

50

Hm

150

F 124
H ft

50

70

D 136

20

C 215

60

Q m3/h

0 U.S. g.p.m.

200

80
70

10
2

100
90

20

30
20

20

50

10

10

m3/h
l/min

10
200

20

40

30
400

600

20
16
12
8
4
0

12

P kW

50
800
B
C

8
4
0

60

20

30

40

50

500

60

70

80

90

1000

1500
S
D

2
0

(%)

80
60
D

40

20

0
6
4

10
2

Q m3/h

10

20

30

40

50

NPSH m

0
8

NPSH ft

NPSH m

m3/h

Q l/min

20

A
B
C

40

(%)

P kW

16

0
0

P HP

NPSH ft

(%)

C 185
40

0
6

NPSH m

200

NM 40/20

AR 200

B 195

20

Hm

200

50

40

A 204

60

60

150

H ft

P kW

6
5
4
3
2
1
0

100

P HP

0
0

50

20

10
2
0

24

Q m3/h

20

30

40

50

60

70

80

90

NPSH ft

0 U.S. g.p.m.

70

H ft

30

130
120
110
100
90
80
70
60
50
40
30
20
10
0

P HP

NM 40/16

35

Hm

200

Hm

150

P kW

100

A 167

H ft

50

P HP

0 U.S. g.p.m.

40

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Characteristic curves n 2900 rpm


200

250

300

0 U.S. g.p.m.

350

A 174

NM 50/16
B 162

10

m3/h

Q l/min

20

30

40

60

50

500

70

80

90

1000

10
8
6
4
2
0

4
2
0

80

Hm

NPSH ft

20

10

100

0 U.S. g.p.m.

20

30

100

40

60

50

150

200

250

90

80

300

90

300

200
H ft

C 209

50
150
40
100

30
20

50
0
0

m3/h
Q l/min

20

30

40

50

500

60

70

80

1000
30

20

P kW

B
C

10

20
10

P HP

10

0
80

60

B
C

40
20
0
10

30
20

10

2
0

Q m 3/h

NPSH ft

8
6

0
20

30

40

50

60

70

50

500

60

70

80

1000

90
1500
20

S
A
B

15

5
S
A
B

40

20

6
4

10

250

60

40

B 229

70

30

350

NM 50/25

A 245

80

70

20

60

Q m3/h

m3/h

Q l/min

10

0
8

0
0

5
3
80

20

100

10

(%)

(%)
NPSH m

0
6

200

50

20

Hm

B 188

NM 50/20

10

(%)

50

40

NPSH m

60

S 209
A 200

15

A
B

60

350

20

1500
A

300

30

NPSH m

P kW

250

P kW

200

150

P HP

Hm

20

150

40

H ft

30

100

70

130
120
110
100
90
80
70
60
50
40
30
20
10
0

H ft

150

80

25

P HP

100

Q m3/h

20

30

40

50

60

70

80

90

NPSH ft

0 U.S. g.p.m.
40

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Characteristic curves n 2900 rpm


0 U.S. g.p.m. 100

200

300

400

0 U.S. g.p.m. 100

500

30
A 146

NM 65/12

30

60

600

NM 65/16

130
120
110
100
90

H ft

50

Hm

500

C 150

40

Hm

E 123

400

B 160

70

20

300

AR 167

80

C 134

200

A 175

40

90

D 143

80
70

30

20

60

20

50

60

70

80

1000

90

100 110 120

1500

2000
A

P HP

2
0

(%)
10

0 U.S. g.p.m.

60

50

200

70

80

300

A 208

60

64

90

400

68

70

10
0

Q m3 /h 20 30 40 50 60 70 80 90 100 110 120 130 140

0 U.S. g.p.m. 100

200

A 252

90

180

300
56

60

400

NM(S) 65/250

H ft
120

66

B 240

80

140

40

68%

100

240
70
220
200

60

l/s 4

12

60
1000
16

80

100
1500

20

24

28

120
2000
32

P kW

36

20
15
10

Q m3/h 20

40

60

80

100

120

NPSH m

12

16

80

100
1500

20

24

28

40

30

20

20
10

NPSH ft

NPSH m

72.024

60
1000

30
20

40
500

180

10

l/s

20

28

10

0 Q m3/h
0 l/min
0

A
B
C

20

50

140

P kW

40
500

67

P HP

0 Q m3/h 20
0 l/min

280
260

80
20

300

67

C 218
30

20

70

73%

A
AR
C B

64
72

8
4
0

160

C 190

A
20
AR
16
B
C
12

600

NM 65/20

2000

B 198

50

Hm

500

100 110 120 130 140

0
130

100 110 120

90
1500

H ft

60

40

NPSH m

20

30

80

40

0
8

Q m3/h 20

70

60

20

60
1000

0
8

50

12

20

40

40

30
500

80

Hm

(%)
NPSH m

m /h 20

Q l/min

A
C

80
60

16

10
8
6
4
2
0

0
0

P HP

40

NPSH ft

30
500

10

NPSH ft

P kW

m /h 20

Q l/min

40

0
130

25

20
15

10
2

0
140

26

10

P HP

0
0

P kW

H ft

50

10

5
0

Q m3/h

20

40

60

80

72.025

100

NPSH ft

10

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Characteristic curves n 2900 rpm


0 U.S. g.p.m.

200

400

600

800

45

60

140

A 176
B 167

200

400

A 210

NM 80/16

40

0 U.S. g.p.m.

60 65

120

600

70
73

35

NM(S) 80/200

180

74

E 140

80

20

75

50

160

B 198
76%

H ft

100

Hm

25

C 155
D 147

H ft

30

Hm

800

140

60

40

15
40

120

10
50
1000

Q m /h

l/min

100

150
2000

30

3000
A
B

16

P kW

12
D
E

20

12

0
0

Q m /h

l/s

50

100
1000

l/min
10

2000
20

30

3000
40

30

A
B

(%)

80
D
E

60

P kW

0
C

100
200

150

20

50

40

30
20

P HP

20

0
0

P HP

20
200

10
10

40

25

20

20

10
2
0

100

Q m /h
3

50

0 U.S. g.p.m.

100

200

600
68

72

90

74

B 250

76

76

C 238

Hm

300

77%

80
70

250

D 226
200

60

E 207
50
150
40
68
3

0
0

Q m /h

l/s

50

100
1000

l/min
10

2000
20

30

100
200

150
3000
40

50

60

80

40

A
B 60
C
D 40

P HP

P kW

30

20

20
0

8
6
4
2
0

Q m3/h

50

100

150

72.028

25
20
15
10
5
0
200

NPSH ft

NPSH m

10
0

800

NM(S) 80/250

15

4
2

0
200

150

400

A 264

NPSH m

NPSH ft

H ft

NPSH m

27

5
0

Q m3/h

50

100

150

72.027

0
200

NPSH ft

20

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Characteristic curves n 2900 rpm


600
65

A 219

60

800
70

74

1000

76

1200

NM(S) 100/200
78

B 210

100

0 U.S. g.p.m.

400

600

800

200

A 265

79%

60

90

180

64

68

1000

NMS 100/250
74

78

160

65

20

l/s 10

20

100

150
2000

30

200

40

50

60

70

P kW

50

l/s 10

20

100

150
2000

30

200

30

40

40

50

60

70

300
5000
80

100
80

60

40

40

20

20

20
0

10

6
16

NPSH ft

26

NPSH m

10

250
4000

3000

60

10

NPSH m

H ft

Hm

50
1000

60

4
2

0 Q m3/h
0 l/min

80

40

80

40

20

150

60
300
5000

250
4000

3000

50

80

P kW

200

60
100

70

50
1000

30

8
20

6
4

10

2
0

Q m3/h 50

250

70

120

E 168

0 Q m3/h
0 l/min

H ft

40
74

74%

B 241
140

30

80

76

P HP

Hm

C 195

D 180

300

72

79

50

1200

100

150

200

250

72.033

6
300

28

P HP

400

Q m3/h 50

100

150

200

250

72.034

0
300

NPSH ft

0 U.S. g.p.m.

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Dimensions and weights


1

2
fM

fM
l1

a
DN2

l1

l2

l2
DN2

DN2

DN2

DN1

g2*

DN1

h2

h2

g1

h1

h1

4.93.083.1

n3

m1

b
m5

b1

w1

n2
n1

m4

n5

kg
a

fM

h1

h2

50

32

80 405 112 140 240


80

32/16BE
32/16A/A
32/20D/A
32/20C/A
32/20A/A

50

32

50

32

NM
NM
NM
NM
NM

40/12C/A-F/A
40/12A/B
40/16C/B
40/16B/B
40/16A/B

65

40

65

40

NM
NM
NM
NM
NM
NM
NM
NM

40/20C/A-D/A
40/20A/A-AR/A-B/A
40/25C/C
40/25B/C
40/25A/C
50/12F/B
50/12D/B
50/12A/B-S/B

NM 50/20B/C
NM 50/20A/C
NM 50/20S/C

h4

s1

mm

NM
NM
NM
NM
NM

NM 50/16A/B-B/B

NM
DN1 DN2

m2
m1

n1

n2

NM 32/12DE-FE
NM 32/12SE-AE

g2

4.93.078.1

m2

Picture

65

65

65

410
132 160 260
450
288
450
80 475 160 180 298
298
475

410
112 140 240
450
260
450
80 475 132 160 270
270
475
80

495
298
160 180
525
320
640
40 100 690 180 225 365
715
260
470
50 100 495 132 160 270
270
495
40 100

65

50 100 525 160 180 320

65

640
50 100 690 160 200 345
720

h4

m1 m2

n1

n2

n3

n5

w1

b1

s1

l1

l2

93

97 245

100 70 190 140 37

50

14

100 70 240 190 47

50

14

62
100 70 240 190 60
60

50

14

100 70 210 160 37

50

14

47
100 70 240 190 45
45

50

14

100 70 265 212

60
49

50

14

125 95 320 250 50

65

14

47
100 70 240 190 45
45

50

14

100 70 265 212 49

50

14

127 141 320


400
140 153 460
460

250
290
290
140 140 295
295
120 120

250
290
290
119 119 295
295
100 113

295
320
400
175 175 460
460
290
121 137 295
295
140 140

m4 m5

g1

g2
24-24
27-26

12

12

12

12

12

12

15

12

14

70,5-64
100
109
131

34
39
42
47
51
29-27
32
39
46
48
54-53
73-67-67
108
117
139
40
47
49-49

100 70 265 212 40

50

14

125 95 320 250 50

65

14

125 95 280 212

60
49

65

14

80

320
525
65 100 640 160 200 345
690
345
345
715

49
125 95 280 212 40
40
40

65

14

NM 65/20C/B
NM 65/20B/B

80

65 100 715 180 225 365

125 95 320 250 50

65

14

NM 65/20A

80

65 100 762 202 225 408 22 125 95 320 250

254 20

80

90

14

14 155 175 182 400 360

42* 185

NM 65/25C

80

65 100 762 202 250 408

254 20

80

90

18

14 175 190 182 400 360

42* 201

100

545
340
670
365
80 125 720 180 225 365
745
365
745
365

NM 80/20B

100

80 125 787 202 250 408 22 125 95 345 280

NM 80/25E

100

80 125 787 202 280 408

NM
NM
NM
NM
NM

50/25C/C
50/25B/C
50/25A/C
65/12E/B
65/12A/B-C/B

NM
NM
NM
NM

65/16D/B
65/16C/C
65/16B/C
65/16A/C-AR

NM
NM
NM
NM
NM

80/16E/B
80/16D/C
80/16C/C
80/16B/C
80/16A/C

NM 100/200E/B*
NM 100/20D

65
80

695
50 100 720 180 225 365
720
500
298
65 100
160 180
530
320

125 100 125

345
800 200
280
408
787 202

160 120 360 280

60
50
125 95 320 250 50
50
50

2
2

160 120 400 315


160 120 360 280

* Version without coupling guard

Pumps with packed gland, dimensions available on request (excluded NMS).

29

465
175 175 465
465
300
134 156
325

15

15

122
145
151
51,9
70,7-64,7

15

320
150 172 410
410
460

15

70,5
93
112
127

155 175 460

15

136
141

320
415
165 193 415
465
465

15

77,5
101
120
132
138

65

254 20

80

90

18

14 170 194 182 400 360

42* 194

254 20

80

90

18

14 191 210 182 400 360

42* 203

80

69
90

18

239 298 258


12
180 212
182 400 360
14

6 179
42* 195

216 20
254 20

14

NM EI

Close Coupled Centrifugal Pumps


with flanged connections

Dimensions and weights


AG
fM

AS
l1

l2

a
DN2

h2

DN1

g1

h1

4.93.083.1

m2

n3

m1

n1

mm

NM

Picture

kg
DN 1 DN 2

NM EI 32/12DE-FE
NM EI 32/12SE-AE

n2

fM

AG

AS

h1

h2

h4

m1

m2

n1

n2

n3

l1

l2

g1

435

190

105

112

140

398

100

70

190

140

37

50

14

93

97

245

12

440
470
470
485
485

190
210

105
118

132

160

418

100

70

240

190

47

50

14

120

120

210

118

160

180

446
454
454

100

70

240

190

62
60
60

50

14

140

140

440
470
470
485
485

190
210

105
118

112

140

398

100

70

210

160

37

50

14

100

113

210

118

132

160

418
426
426

100

70

240

190

47
45
45

50

14

119

119

50

32

80

250
290
290
295
295

30,4-30,4
32,4-33,4
40,4
46,5
49,5
54,5
59

NM EI
NM EI
NM EI
NM EI
NM EI

32/16BE
32/16A/A
32/20D/A
32/20C/A
32/20A/A

50

32

80

50

32

80

NM EI
NM EI
NM EI
NM EI
NM EI

40/12C/A-F/A
40/12A/B
40/16C/B
40/16B/B
40/16A/B

65

40

80

65

40

80

NM EI 40/20C/A-D/A
NM EI 40/20AR/A-B/A
NM EI 40/20A/A

65

40

100

505
525
535

210
281
281

118
153
153

160

180

454
482
528

100

70

265

212

60
49
49

50

14

140

140

295
320
320

12

NM EI 40/25C/C
NM EI 40/25B/C

65

40

100

640
690

281

153

180

225

573

125

95

320

250

50

65

14

175

175

400
460

15

NM EI 50/12F/B
NM EI 50/12D/B
NM EI 50/12A/B-S/B

65

50

100

490
505
505

210

118

132

160

418
426
426

100

70

240

190

47
45
45

50

14

121

137

290
295
295

12

47,5
54,5
57-57

NM EI 50/16B/B
NM EI 50/16A/B

65

50

100

525
535

281

153

160

180

482
528

100

70

265

212

49

50

14

127

141

320

14

72
85,3

NM EI 50/20B/C
NM EI 50/20A/C

65

50

100

640
690

281

153

160

200

553

100

70

265

212

40

50

14

140

153

400
460

15

114,8
123,8

NM EI 50/25C/C

65

50

100

695

281

153

180

225

573

125

95

320

250

50

65

14

175

175

465

15

136,8

210
281
281

118
153
153

160

180

482
528
528

125

95

280

212

60
49
49

65

14

134

156

300
325
325

15

59,9
72,7
85,5

250
290
290
295
295

12
12

12
12

33,4-35,4
39,5
46,5
53,5
56
61-62
75-75
87,8
122,8
131,8

NM EI 65/12E/B
NM EI 65/12C/B
NM EI 65/12A/B

80

65

100

510
530
540

NM EI 65/16D/B
NM EI 65/16C/C
NM EI 65/16B/C

80

65

100

525
640
690

281

153

160

200

528
553
553

125

95

280

212

49
40
40

65

14

150

172

320
410
410

15

85,3
107,8
126,8

NM EI 80/16E/B
NM EI 80/16D/C
NM EI 80/16C/C

100

80

125

555
670
690

281

153

180

225

548
573
573

125

95

320

250

60
50
50

65

14

165

193

320
415
415

15

92,3
115,8
134,8

30

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Dimensions and weights


1

fM
l1

l2
DN2

DN1

DN2

h2
H
h1

A
h1
HA
A

m2
m1

4.93.466.1

n
n1 2

b
w

AA

2
m

n2
n1

B
BB

2
fM
l1

l2
DN2

DN1

DN2

h2
H

h1

h1
A

m2
m1

g2

4.93.466.1

s
b

m5
m4

n
n1 2

s1

2
m

b1
n5

n2
n1

w1

mm
Picture

NMS

kg
DN1 DN2

fM

h1

h2

m1 m2

n1

n2

n5

w1

279 20

AA

b1

s1

l1

l2

15 177 189 333

BB m4

m5 HA

g2

NMS 65/250B

80

65 100 961 200 250 486 160 120 360 280

80

70

18

440

400

20

269

NMS 65/250A/A

80

65 100 1074 200 250 500 160 120 360 280 318

80

70

18

19

200 200 406 355

305

25

321

NMS 80/200A

100 80 125 986 180 250 466 125 95 345 280 279

65

65

14

19

170 194 412 328

279

20

256

NMS 80/250D

100 80 125 986 200 280 486 160 120 400 315

80

70

18

440

400

20

276

NMS 80/250C/A

100 80 125 1099 200 280 500 160 120 400 315 318

80

70

18

19

200 210 406 355

305

25

345

NMS 80/250B/A

100 80 125 1164 225 280 550 298 258 410 315 356

80

18

19

225 225 445 361

311

34

437

NMS 80/250A/A

100 80 125 1235 280 280 672 260 220 410 315

406 25

100 18

24 275 275 443

500

450

534

NMS 100/200C

125 100 125 986 200 280 486 160 120 360 280

279 20

80

70

18

15 180 212 333

440

400

20

270

NMS 100/200B/A

125 100 125 1099 200 280 500 160 120 360 280 318

80

70

18

19

200 212 406 355

305

25

338

NMS 100/200A/A

125 100 125 1164 225 280 550 298 258 410 315 356

80

18

19

225 225 445 361

311

34

426

NMS 100/250B/A

125 100 140 1250 280 280 672 260 220 410 315

500

450

545

NMS 100/250A/A

125 100 140 1324 280 280 712 260 220 410 315 457

100

368

40

648

279 20

440 25
-

Flanges EN 1092-2

100 18
-

15 191 211 333

24 275 275 443

24

18

mm

DN
DK

4.93.094

DE

DN

DG

DK

DE

32
40
50
65
80
100
125

76
84
99
118
132
156
184

100
110
125
145
160
180
210

140
150
165
185
200
220
250

31

W
N
4
4
4
4
8
8
8

19
19
19
19
19
19
19

275 275 516 479

Holes
DG

18
18
20
20
22
24
24

B -NM , B -NMS

Close Coupled Centrifugal Pumps


with flanged connections

Dimensions and weights


1

2
fM

fM
a

l1

l2

DN2

l1

l2
DN2

DN2

DN2

DN1

g2*

DN1

h2

h2
A

H
g1

h1

h1

4.93.083.1

g2

4.93.078.1

m2

m1

n3

m2
m1

n2

h4

m5

n1

s1
b1

w1

n2
n1

m4

n5

mm
Picture

kg

B- NM
DN1 DN2

fM h1

h2

h4 m1 m2 n1

n2

n3

n5 w1

b1

s1

l1

l2

12

250
290

12

38,5
42

290
140 140 295
295

12

47,5
56,5
58

14

100 113

250
290

12

33-31
36

14

290
119 119 295
295

12

43
50
53

50

14

140 140

295
375

12

59,5-59
80,5-75

65

69

14

124
130
159,5

50

14

290
121 137 295
295

12

44
52
54,5-54

50

14

127 141 375

14

80-74,5

216 20

50

69

14

12 140 153 234 298 258

123
132
154

216 20

65

69

14

12 175 175 174 298 258

135
156
161

65

14

100 70 190 140 37

50

14

93

B-NM 32/16B
B-NM 32/16A/A

50

32

80

410
132 160 260
450

100 70 240 190 47

50

14

120 120

B-NM 32/20D/A
B-NM 32/20C/A
B-NM 32/20A/A

50

32

288
450
80 475 160 180 298
298
475

45
100 70 240 190 60
60

50

14

B-NM 40/12C-F
B-NM 40/12A/A

65

40

80

410
112 140 240
450

100 70 210 160 37

50

B-NM 40/16C/A
B-NM 40/16B/A
B-NM 40/16A/A

65

40

450
260
80 475 132 160 270
270
475

47
100 70 240 190 45
45

50

B-NM 40/20C/A-D/A
B-NM 40/200A/A-B/A

65

40 100

495
298
160 180
580
320

100 70 265 212

60
49

B-NM 4025/C/C
B-NM 4025/B/C
B-NM 4025/A/C

65

635
40 100 685 192 225 377 12 125 95 320 250
710

B-NM 50/12F/A
B-NM 50/12D/A
B-NM 50/12A/A-S/A

65

470
260
50 100 495 132 160 270
270
495

47
100 70 240 190 45
45

65

50 100 580 160 180 320

100 70 265 212 49

65

695
50 100 745 192 200 377 32 100 70 265 212
769

B-NM 5025/C/C
B-NM 5025/B/C
B-NM 5025/A/C

65

685
50 100 710 192 225 377 12 125 95 320 250
710

B-NM 65/125A/B-C/B

1*

1*

B-NM 50/160A/B-B/B
B-NM 50/200B/C
B-NM 50/200A/C
B-NM 50/200S/C

125 95 280 212 49

49
125 95 280 212
40

80

65 100 585 160 180 320

B-NM 65/160D/B
B-NM 65/160C/C

80

575
320
65 100
160 200
660
345

B-NM 65/160B/C
B-NM 65/160A/C-AR

80

65 100

745
192 200 377 32 125 95 280 212
770

B-NM 65/200B/B-C/B
B-NM 65/200A/B

80

65 100 775 192 225 377 12 125 95 320 250


825 202
408 22

B-NM 65/250C/B

134 156 380

15

80,5-74,5

375
150 172
430

15

83,5-79
106

133
156

14

216 20

65

69

14

12 150 172 234 298 258

216
20
254

65

69
90

14

298 258
12
155 175 239
14
245 400 360

6 183-169,5
42* 200

254 20

80

90

18

14 175 190 245 400 360

42* 210

65 100 825 202 250 408 2

160 120 360 280

1*

100

605
340
80 125
180 225
685
365

60
125 95 320 250
50

B-NM 80/160C/C
B-NM 80/160B/C
B-NM 80/160A/C

100

775
80 125 800 192 225 377 12 125 95 340 250
800

32

12 175 175 174 298 258

80

* Version without coupling guard

216 20

65

B-NM 80/160E/B
B-NM 80/160D/C

B-NM

80 405 112 140 240

g2

32

1*

m4 m5 g1

97 245

50

27-27
30-28

B-NM 32/12D-F
B-NM 32/12S-A

216 20

65

14

65

69

14

375
165 193
430

12 165 193 239 298 258

15

94
114

140
166
172

B -NM , B -NMS

Close Coupled Centrifugal Pumps


with flanged connections

Dimensions and weights


1

fM
l1

l2
DN2

DN1

DN2

h2
H
h1

A
h1
HA
A

m2
m1

4.93.466.1

n
n1 2

b
w

2
m

AA

n2
n1

B
BB

2
fM
l1

l2
DN2

DN1

DN2

h2
H

h1

h1
A

m2
m1

g2

4.93.466.1

s
b

m5
m4

n
n1 2

s1

2
m

b1
n5

n2
n1

w1

mm
Picture

kg

B-NMS
DN1 DN2 a

fM h1

h2

H m1 m2 n1 n2

n5 w1

279 20 80

AA b1

s1

l1

l2

15 177 189 333

BB m4

B-NMS 65/250B/A

80

65 100 961 200 250 486 160 120 360 280

B-NMS 65/250A/A

80

65 100 1074 200 250 500 160 120 360 280 318

B-NMS 80/200B/A

100 80 125 936 180 250 387 125 95 345 280

B-NMS 80/200A/A

100 80 125 986 180 250 486 125 95 345 280 279

B-NMS 80/250E/A

100 80 125 936 200 280 407 160 120 400 315

254 20 80

B-NMS 80/250D/A

100 80 125 986 200 280 486 160 120 400 315

279 20 80

B-NMS 80/250C/A

100 80 125 1099 200 280 500 160 120 400 315 318

B-NMS 80/250B/A

100 80 125 1164 225 280 550 298 258 410 315 356

B-NMS 80/250A/A

100 80 125 1235 280 280 672 260 220 410 315

406 25

B-NMS 100/200E/A

125 100 125 882 200 280 386 160 120 360 280

B-NMS 100/200D/A

125 100 125 936 200 280 407 160 120 360 280

B-NMS 100/200C/A

125 100 128 986 200 280 486 160 120 360 280

279 20 80

B-NMS 100/200B/A

125 100 125 1099 200 280 500 160 120 360 280 318

80

70

18 19

200 212 406 355

B-NMS 100/200A/A

125 100 125 1164 225 280 550 298 258 410 315 356

80

18 19

225 225 445 361

B-NMS 100/250B/A

125 100 140 1250 280 280 672 260 220 410 315

B-NMS 100/250A/A

125 100 140 1324 280 280 712 260 220 410 315 457

254 20 65
-

70 18

70

80

60 14

65

65

14 15

440

400

305

25

350

310

170 194 412 328 440 279

20

310

440

400

20

305

25

60 18

15 191 210 331

350

70 18

15 191 212 333

18 19

18 19

200 210 406 355

225 225 445 361

20

80

70

80

311

34

100 18

24 275 275 443

500

450

216 20 80

69 18

12 180 212 322

298

258

254 20 80

60 18

15 180 212 331

350

310

70 18

15 180 212 333

440

400

20

305

25

311

34

500

450

368

40

440 25
-

100

100 18
-

24 275 275 443

18 24

DN
DK
DE

33

DN

DG

DK

DE

32
40
50
65
80
100
125

76
84
99
118
132
156
184

100
110
125
145
160
180
210

140
150
165
185
200
220
250

Holes

N
4
4
4
4
8
8
8

275 275 516 479

mm

DG

4.93.094

15 175 194 331

200 200 406 355

m5 HA g2

Flanges EN 1092-2

18 19

19
19
19
19
19
19
19

18
18
20
20
22
24
24

353
266
287

250

352

NM, NMS

Close Coupled Centrifugal Pumps


with flanged connections

Features
NM
Cutting edge hydraulics
The geometry of the impeller and the pump casing are
optimized to achieve maximum efficiency and the best
suction capability.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic parts in contact with the pumped
liquid allows NM and NM4 series pumps to be selected for
use with different types of liquids.

Compact Design
The compact design allows for easy installtion even in
confined spaces.

Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection to the end user whilst
allowing for inspection of the mechanical seal.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability under all operating conditions.

NMS
Cutting edge hydraulics
The geometry of the impeller and the pump casing are
optimized to achieve maximum efficiency and the best
suction capability.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic parts in contact with the pumped
liquid allows NMS and NMS4 series pumps to be selected
for use with different types of liquids.

New lantern bracket construction


The lantern brackets incorporate a thrust bearing on the
hydraulic side which guarantees the elimination of additional loads on the motor bearings. The flange is sized to
be used with standard motors B35.

Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection to the end user whilst
allowing for inspection of the mechanical seal.

Simplified motor maintenance


The presence of the thrust bearing on the hydraulic side
makes it easier to remove the motor, facilitating maintenance operations and eliminating the risks of damage to
the hydraulic parts.

34

09/2016

NM4, NMS4

Close Coupled Centrifugal Pumps


n 1450 rpm
Construction
Close-coupled centrifugal pumps; electric motor with extended
shaft directly connected to the pump up to 15 kW, new bracket
construction for standard motors (Stub-shaft construction) from
18,5 to 75 kW with integrated thrust bearing. Pump casing with axial
suction and radial delivery on top, main dimensions and performance according to EN 733 with additional sizes for completion.
NM(S)4: version with pump casing and lantern bracket in cast iron.
B-NM(S)4: version with pump casing and lantern bracket/casing
cover in bronze. (the pumps are supplied fully painted).
Connections
Sizes
NM4 25/...
from NM4 32/.. to NMS4 150/..

Connections
Threaded ports ISO228
Flanges according to PN 10, EN 1092-2

Counter-flanges (on request)


Sizes
from NM4 32/.. to NM4 50/..
from NM4 32/.. to NMS4 150/..

Flanges
Screwed flanges EN 1092-1, PN 16
Flanges for welding EN 1092-1, PN 10

Version with frequency converter (on request)

Applications
For clean liquids without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0,2%).
For water supply. For heating, air conditioning, cooling and
circulation plants. For civil and industrial applications.
When low noise operating is required. For irrigation.

Operating conditions
The electropumps NM4, B-NM4, NMS4, B-NMS4 series comply with the European
Regulation no. 547/2012.

Materiali
Components
Pump casing
Lantern bracket NM4
Casing cover for NMS4
Lantern bracket NMS4
Impeller

NM4, NMS4

B-NM4, B-NMS4

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Liquid temperature from -10 C to +90 C.


Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar (16 bar for
NM4 65/16 and NM4 80/16).
Continuous duty.

Motor
4-pole induction motor, 50 Hz (n 1450 rpm).
NM4, NMS4: three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% from 4 to 75 kW.
Insulation class F.
Protection IP 54 (IP 55 for NMS4).
Motor suitable for operation with frequency converter from 1,1 kW.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from 7,5 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.

Cast iron GJL 200 EN 1561

Shaft

Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
For NM4 25/125 - 25/160 - 25/200 - NM4 32/16 - 32/20 - 40/20
AISI 303 up to 1,1 kW
Cr Ni Mo steel

Mechanical seal
Counter-flanges

AISI 430 from 1,5 kW to 75 kW


AISI 316
Carbon - Ceramic - NBR
Steel Fe 430B UNI 7070

Special features on request


-

Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).


Protection IP55. - Special mechanical seal.
Higher or lower liquid or ambient temperatures.
Motor suitable for operation with frequency converter up to 0,75 kW.

Coverage chart n 1450 rpm


10 U.S. g.p.m. 20

30

40

50

100

200

300

400 500

1000

2000

3000

70
200
50
NMS4 80/400

NMS4
100/400

40

NMS4
125/400

H
ft

NMS4
150/400

100

30

NM4
80/315

NM4 65/31

20
NM4 40/25

NM4 50/25

NM4
80/25

NM4 65/25

NM4 40/20

NM4 25/200
NM4 32/20

NM4 25/160

NM4 32/16

NM4 40/16

NM4 50/20

NM4
65/20

NM4 50/16

NM4
65/16

NMS4
150/315

NM4
100/250

m
10

NM(S)4
100/315

NMS4
125/315

50
40

NM4
125/250

NM4
80/20

30

NM4
100/20

20

NM4
80/16

NM4 25/12

10

2
40

50

m 3/h 5
l/min
100

10
150 200

20
30
300 400 500

40

50

100
1000

200

300
5000

7
700
400 500
10000
72 849 C

35

NM4 EI

Close Coupled Centrifugal Pumps


with flanged connections

Pumps with frequency converter


The NM4 EI pumps are available with power from 0,25 kW up to 11 kW, the pumps are equipped with I-MAT
installed on board which allows to realize a variable-speed system extremely compact and efficient, ideal in
applications of water supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,25 kW to 11 kW
Control range from 870 to 1450 rpm (4-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases

Operating modes
H

Constant pressure mode


with pressure transducer

+
-

In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H

Proportional pressure mode


with pressure transducer

+
-

In this mode the system changes the working pressure according to the required
flow rate.

Constant flow mode


with flow meter
In this mode the system maintains a constant flow rate value in a point of the installation according to the required pressure.

Fixed speed mode


with setting of the speed preferential rotation.
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range.

H
max

+
min

Constant temperature mode


with temperature transducer
In this mode the system keeps the temperature constant inside a system by changing the speed of the pump.
36

NM4, NMS4

Close Coupled Centrifugal Pumps

Performance n 1450 rpm


B - NM4

B- NM4
B- NM4
B- NM4
B- NM4
B- NM4

25/160BE
25/160AE
25/200C/A
25/200B/A
25/200A/B

B - NM4

B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4

32/16B
32/16A
32/20B
32/20A/A
40/16C
40/16B
40/16A/A
40/20B/A
40/20A/A
4025/C/B
4025/B/B
4025/A/B

B - NM4

B-NM4 50/16B/A
B-NM4 50/16A/A

B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4
B-NM4

5025/D/A
5025/C/B
5025/B/B
5025/A/B
65/16C/B
65/16B/B
65/16A/B
65/16S

B-NMS4

B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4

80/315B/A
80/315A/A
80/315S
80/400C/A
80/400B/A
80/400A/A

P2

NM4
NM4
NM4
NM4
NM4
NM4
NM4

25/12A/A
25/160BE
25/160AE
25/200C/A
25/200B/A
25/200A/B

kW

HP

0,25
0,37
0,37
0,37
0,55
0,75

0,34
0,5
0,5
0,5
0,75
1

NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4

32/16BE
32/16AE
32/20BE
32/20A/A
40/16C/A
40/16B/A
40/16A/B
40/20B/A
40/20A/A
40/25C/B
40/25B/B
40/25A/B

kW

HP

0,37
0,37
0,55
0,75
0,37
0,55
0,75
1,1
1,1
1,5
2,2
3

0,5
0,5
0,75
1
0,5
0,75
1
1,5
1,5
2
3
4

P2

NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4
NM4

50/16B/B
50/16A/B
50/20C/B
50/20B/B
50/20A/B
50/25D/A
50/25C/B
50/25B/B
50/25A/B
65/16C/B
65/16B/B
65/16A/B
65/16S
65/20B/A
65/20A/A
65/25B/A
65/25A/B
65/31C/B
65/31B/B
65/31A/B

kW

HP

1,1
1,1
1,1
1,5
2,2
2,2
2,2
3
4
1,1
1,1
1,5
2,2
2,2
3
4
5,5
5,5
7,5
9,2

1,5
1,5
1,5
2
3
3
3
4
5,5
1,5
1,5
2
3
3
4
5,5
7,5
7,5
10
12,5

P2

NM4 - NMS4
NM4 80/16C/B
NM4 80/16B/B
NM4 80/16A/B
NM4 80/20C/A
NM4 80/20B/A
NM4 80/20A/A
NM4 80/25C/A
NM4 80/25B/B
NM4 80/25A/B
NM4 80/31C/B
NM4 80/31B
NM4 80/31A
NMS4 80/315S
NMS4 80/400C/A
NMS4 80/400B/A
NMS4 80/400A/A

1,2

1,5

1,89

2,4

3,6

4,2

4,8

5,4

6,6

7,5

8,4

9,6

10,8

12

13,2

15

l/min

16

20

25

31,5

40

50

60

70

80

90

100

110

125

140

160

180

200

220

250

H
m

6,1
7,7
9,2
11,5
13,2
14,5

6,05
6
5,9 5,8 5,5 5,2 4,8 4,4 3,9 3,3
7,65 7,6 7,55 7,5 7,2 6,9 6,6 6,1 5,5 4,6 3,6
9,15 9,1 9,05
9
8,7 8,5 8,2 7,8 7,2 6,5 5,6 3,7
11,4 11,4 11,3 11,2 11,1 10,9 10,7 10,5 10,2 9,9 9,5 8,7 7,8 6,2
13,2 13,2 13,1 13,1 13 12,9 12,7 12,5 12,3 12 11,6 11,1 10,4 9,1
14,5 14,5 14,5 14,5 14,4 14,3 14,2 14 13,8 13,6 13,3 12,8 12,2 11,2

4,1
7,4
9,7

4,8
7,5

4,1

Q
m3/h

P2

NM4

Q
m3/h

kW

HP

1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
9,2
11
15
18,5
18,5
22
30

1,5
2
3
3
4
5,5
5,5
7,5
10
12,5
15
20
25
25
30
40

l/min

H
m

2,4

3,6

4,8

5,4

7,5

8,4

9,6

10,8

12

13,2

15

16,8 18,9

21

24

27

30

40

50

60

80

90

100

125

140

160

180

200

220

250

280

350

400

450

500

7,6 7,5 7,4 7,2 7,1 6,9


9
8,95 8,9 8,7 8,6 8,5
12,5 12,4 12,3 12 11,8 11,6
14,3 14,2 14,1 13,9 13,7 13,5
6,1
6
7,6 7,6
9,6 9,6
13 12,9
14,8 14,7
17,4 17,3
21,4 21,5
22,9 22,8

6,3
7,9
10,6
12,9
5,9
7,6
9,6
12,7
14,5
17,2
21,3
22,9

5,9
7,5
10
12,3
5,8
7,6
9,4
12,6
14,4
17
21,2
22,8

5,2
6,8
8,9
11,3
5,6
7,3
9,3
12,4
14,2
16,8
21
22,5

4,2
6
7,6
10,2
5,4
7,1
9,1
12,2
14
16,6
20,9
22,5

5,1
6,2 4,7
8,9 7,5
5,2
5
4,5 3,9 3,1 2,3
6,9 6,6 6,3 5,7
5
4
2,7
9
8,8 8,4 7,9 7,2 6,4 5,1 3,5
12 11,5 10,8 10
8,6
7
13,8 13,6 13 12,2 11,3 10
16,3 16 15,1 13,8 12,1 10,4 7,2 2,8
20,8 20,5 20 19,5 18,3 16,4 13,3 10
22,2 22 21,8 21,4 20,4 18,9 16 12,6

315

5
8

Q
10,8
m3/h

12

13,2

15

16,8 18,9

21

24

27

30

33

37,8

42

48

54

l/min

180

200

220

250

280

315

350

400

450

500

550

630

700

800

900 1000 1100 1250 1400

8,2
9,6
11,8
13,4
14,9
14,5
17,8
20,7
22,7

8,2
9,6
11,8
13,4
14,9
14,4
17,8
20,7
22,7

8,2
9,6
11,7
13,4
14,9
14,3
17,7
20,7
22,6

8,1
9,5
11,7
13,3
14,9
14
17,5
20,6
22,5

8
9,5
11,5
13,1
14,8
13,7
17,2
20,4
22,4

7,8
9,3
11,3
12,9
14,6
13,4
16,8
20
22,1

7,6
9,1
10,9
12,6
14,4
13
16,4
19,5
21,6
6,1
7,2
8,8
10,2
11,9
14,1
18
21,9
25,8
31
35,9

7,2
8,8
10,4
12,1
14
12,2
15,7
18,9
21
6,1
7,1
8,8
10,2
11,8
14
17,9
21,8
25,7
31
35,9

6,7
8,3
9,8
11,5
13,4
11,2
14,9
18,2
20,2
6
7,1
8,7
10,1
11,7
13,9
17,8
21,7
25,5
30,9
35,8

6,2
7,8
9
10,8
12,8
9,7
13,8
17,1
19,4
6
7
8,7
10,1
11,6
13,8
17,7
21,6
25,3
30,8
35,7

5,5
7,2
8,1
9,9
12
8,1
12,4
15,9
18,3
5,9
7
8,6
10
11,4
13,7
17,6
21,5
25
30,6
35,5

4,4
6,1
6,3
8,2
10,4
5,4
9,7
13,2
16,4
5,8
6,8
8,5
9,9
11,1
13,4
17,3
21,2
24,4
30,2
35,1

3,3
4,9
4,7
6,4
8,6
2,3
6,8
10,6
13,6
5,6
6,6
8,3
9,7
10,8
13,1
16,9
20,8
23,8
29,7
34,6

5,8
9
5,3
6,3
8
9,4
10,2
12,6
16,3
20,2
22,8
28,8
33,8

4,8
5,8
7,6
9,1
9,5
11,9
15,4
19,5
21,5
27,8
32,8

4,2
5,2
7,1
8,6
8,7
11,1
14,4
18,5
20
26,5
31,6

4,5
6,4
8
7,8
10,2
13,1
17,5
18,2
25
30,2

5,2
7
5,7
6,2 4,3
8,8 7,2
10,8 8,5
15,4 12,8
15
11
22,2 18,6
27,8 25

60

66

75

84

96

108

120

132

150

168

180

192

H
m

60

66

75

84

3,1
3,7
6

Q
m3/h

30

33

37,8

42

48

54

l/min

500

550

630

700

800

900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500

H
m

6,1
7,8
10
10,3
12,1
13,9
16,9
20,7
23,7
25,7
30,3
36,3
39,1
46,5
54
61,5

6,1
7,7
10
10,2
12
13,8
16,8
20,6
23,7
25,8
30,5
36,4
39,2
46,3
53,8
61,4

5,9
7,6
9,9
10,1
11,9
13,7
16,7
20,5
23,6
25,8
30,6
36,5
39,3
46,1
53,6
61,3

5,8
7,5
9,8
10
11,8
13,6
16,6
20,4
23,5
25,8
30,7
36,6
39,4
45,8
53,3
61,1

5,5
7,3
9,7
9,8
11,7
13,5
16,3
20,3
23,3
25,8
30,7
36,6
39,5
45,2
53
60,8

5,2
7
9,5
9,5
11,4
13,3
15,9
20
23
25,6
30,7
36,5
39,4
44,5
52,4
60,2

37

4,9
6,8
9,3
9,1
11,1
13
15,4
19,6
22,7
25,4
30,5
36,4
39,3
43,5
51,6
59,4

4,6
6,4
9
8,6
10,6
12,6
14,8
19,1
22,2
25
30,2
36,1
39,2
42,4
50,6
58,4

4
5,9
8,5
7,7
9,8
11,8
13,9
18,2
21,5
24,4
29,6
35,6
38,7
40
48,7
56,5

3,3
5,2
8
6,6
9
11
12,7
17,1
20,5
23,6
28,8
35
38,1
37,2
46,1
54

4,1
7
4,6
7,5
9,6
11,1
15,4
19
22,2
27,5
33,9
37,1
32,5
42
50,5

5,9
5,7
7,9
9,3
13,5
17,2
20,4
25,9
32,5
35,7
26,2
36,5
45,5

6
7,2
11,4
15,1
18,3
24,1
30,9
34,1
18,5
29,5
40

9*
12,7*
15,9
22
29 25,3
32,1 28,3 22,5*
21*
32,5*

210

NM4, NMS4

Close Coupled Centrifugal Pumps

Performance n 1450 rpm

B-NMS4

B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4

100/315C/A
100/315B/A
100/315A/A
100/400C/A
100/400B/A
100/400A/A

NM4 100/20C/A
NM4 100/20B/A
NM4 100/20A/B
NM4 100/25B/B
NM4 100/25A/B
NM4 100/31C
NM4 100/31B
NMS4 100/315A/A
NMS4 100/400C/A
NMS4 100/400B/A
NMS4 100/400A/A

B-NMS4

B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4
B- NMS4

P2

NM4 - NMS4
kW

HP

3
4
5,5
7,5
9,2
11
15
18,5
22
30
37

4
5,5
7,5
10
12,5
15
20
25
30
40
50

125/250B/A
125/250A/A
125/315C/A
125/315B/A
125/315A/A
125/400C/A
125/400B/A
125/400A/A
150/315D/A
150/315C/A
150/315B/A
150/315A/A
150/400C/A
150/400B/A
150/400A/A

NM4 125/25E/B
NM4 125/25D/B
NM4 125/25C/B
NM4 125/25B
NM4 125/25A
NMS4 125/315C/A
NMS4 125/315B/A
NMS4 125/315A/A
NMS4 125/400C/A
NMS4 125/400B/A
NMS4 125/400A/A
NMS4 150/315D/A
NMS4 150/315C/A
NMS4 150/315B/A
NMS4 150/315A/A
NMS4 150/400C/A
NMS4 150/400B/A
NMS4 150/400A/A

kW

HP

5,5
7,5
9,2
11
15
18,5
22
30
37
45
55
18,5
22
30
37
45
55
75

7,5
10
12,5
15
20
25
30
40
50
60
75
25
30
40
50
60
75
100

NM4, NMS4
Standard construction.
B-NM4, B-NMS4 Bronze construction.

48

54

l/min

800

900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500

H
m

9,4
12
15,2
19,5
22,3
26,9
31,5
36,9
41,3
50,2
58,2

9,3
11,9
15,2
19,5
22,3
26,9
31,5
36,9
41,2
50,1
58,1

9,2
11,8
15,1
19,4
22,2
26,8
31,4
36,8
41,1
50
58

9,1
11,7
15
19,3
22,1
26,6
31,3
36,7
41
49,9
57,9

8,9
11,5
14,9
19
21,9
26,2
31,2
36,6
40,7
49,7
57,8

8,5
11,2
14,7
18,7
21,7
25,7
30,8
36,4
40,4
49,4
57,6

8
10,7
14,3
18,2
21,2
24,9
30,2
36
39,8
48,8
57,2

7,3
10
13,8
17,5
20,5
23,8
29,3
35,3
39
48
56,3

6,5
9,3
13,1
16,6
19,8
22,7
28,2
34,5
38
47,1
55,7

5,6
8,4
12,2
15,6
18,8
21,3
26,9
33,4
36,5
46
54,5

4
6,7
10,7
13,8
17,1
18,9
24,6
31,4
34
44
52,7

4,5
9
11,7
15
15,9
21,8
29
31
41,3
50,5

7,5*
10
13,4
13,7
19,8
27,2
28,7
39,5
49

6*
8,4
11,7
11,3*
17,6*
25,3*
26
37
47

84

96

108

120

132

150

168

180

192

210

240

270

300

330

Q
m3/h

P2

NM4 - NMS4

Q
m3/h

60

66

75

84

96

108

120

132

168

180

192

210

240

270

300

330

5,5
8,9
14*
22,2*
33,5*
44*

360

390

420

450

480

l/min 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

H
m

11
14
16,7
19,3
22,7
27,9
31,8
36,8
45,4
51,4
59,2

10,8
13,9
16,6
19,2
22,7
27,8
31,7
36,8
45,3
51,3
59,1

10,5
13,7
16,4
19,1
22,6
27,7
31,6
36,7
45,2
51,2
59

10,1
13,4
16,2
18,9
22,4
27,6
31,5
36,6
45,1
51,1
58,9

9,7
13
15,9
18,7
22,2
27,2
31,1
36,4
44,9
50,9
58,7
22,8
25,6
30,6
35,6
45
50,8
58,8

9,1
12,4
15,4
18,2
21,8
26,5
30,6
35,9
44,4
50,4
58,2
22,6
25,4
30,6
35,6
44,9
50,7
58,7

8,3
11,6
14,6
17,5
21,2
25,6
29,7
35,2
43,7
49,7
57,7
22,3
25,1
30,5
35,5
44,7
50,5
58,6

7,8
11
14,1
17
20,8
24,9
29,1
34,7
43
49
57,2
22
24,9
30,3
35,4
44,5
50,3
58,5

P2 Rated motor power output.


H Total head in m.

7,2
10,4
13,5
16,3
20,1
24
28,5
34,2
42
48,2
56,7
21,7
24,7
30,1
35,3
44
50
58,3

6,2
9,4
12,5
15,3
19,3
22,8
27,3
33,2
40
46,8
55,7
21,1
24,2
29,7
35,2
43,5
49,5
57,9

Rated currents
230 V / 400 V Y

P2

150

400 V / 690 V Y

P2

kW

HP

IN A

IN A

IA/IN

kW

HP

IN A

IN A

IA/IN

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3

0,34
0,5
0,75
1
1,5
2
3
4

1,4
1,65
2,6
3,3
5
6
8,6
11,1

0,8
0,95
1,5
1,9
2,9
3,5
5
6,4

3,7
4,2
4,8
5,2
4,7
5
6,1
9

4
5,5
7,5
9,2

5,5
7,5
10
12,5

8,3
12,5
16
19

4,8
7,2
9,2
11

9,3
7,7
9,4
9,3

11
15
18,5
22
30
37
45
55
75

15
20
25
30
40
50
60
75
100

22,5
29
34,5
40,5
55
67
81
96
130

13
16,7
19,9
23,4
31,8
38,5
46,8
55,4
75

6,9
7
6,4
6,7
6,7
6,8
6,9
7,5
6,8

P2
Rated motor power output.
IA/IN D.O.L. starting current / Nominal current

38

4,4
7,4
10,4
13,3
17,4
20,2
24,9
31
37
44
53,5
20
23,3
29
34,6
42,5
48,5
57

5,1
8,2
10,9
15
17
22
28,4
33
40,5
50,5
18,6
22
27,9
33,7
40,5
47
55,5

5,8
8,2
12,4
13,5
18,5
25,3
28,5*
36*
46,5*
17
20,4
26,5
32,5
38,5
45
54

9,3
9,5*
14,3*
21,6*
23,5*
31,5*
42,5*
15,1
18,5
24,9
31
36
43
52

13
16,5
23
29,2
33,5
40,5
49,5

10,6 8*
14,1 11,6* 8,9*
20,8 18,3* 15,4*
27,1 24,7* 21,8* 18,5*
30,5 27* 23,5* 19,5*
38 35* 32* 28,5*
47 44* 41* 37,5

Maximum suction lift 1-2 m.


Tolerances according to UNI EN ISO 9906:2012

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


10

A 131.5

15

20

45

25

10

10

A 161.5

40

20

NM4 25/12

50

0 U.S. g.p.m.

54

20
45

30

50 52
53.5%

B 150

52

18

56

45

20
40

Hm

16

H ft

Hm

56

25

50

57%

54

15
4

14

10

0
0

3
Q m /h 1

l/s 0.2

l/min

2
20

3
40

0.4

60

0.6

0.8

1.2

10

6
100

80

12

1.4

1.6

0.2

0
0

Q m /h

l/s

l/min 20
0.4

3
40

0.6

5
80

60
0.8

1.2

1.4

6
100
1.6

7
120

2.2

1.8

0.3

0.2

0.1

0.3

P kW

P HP

P kW

0.1

0.4

0.2

0.2

P HP

50

30

NM4 25/160

H ft

0 U.S. g.p.m. 5

0.1

2
5

NPSH m

10

NPSH ft

NPSH m

1
0

15

Q m3/h 1

U.S. g.p.m.

72.071

25

NM4 25/200

40

C 184

10

20

H ft

Hm

30

5
10

/h
Qm
l/min

50

10
100

150

15
250

200
A

0,8

0,6

C
0,4

P HP

P kW

0
0

0,2

40
C

NPSH m

20

0
8

25

20
15

10

NPSH ft

(%)

60

25

20
15

10
0

50

B 194

0,7
0,6
0,5
0,4
0,3
0,2
0,1
80

A 200

Q m /h
3

10

72.076N

15

39

5
0

Q m3/h

72.072

NPSH ft

0.1

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


0 U.S. g.p.m.10

20

A 164
8

50

30
55 58
60

40

0 U.S. g.p.m.

50
30

NM4 32/16

62

15

40

50

60
50

NM4 32/20

B 195

40

62

35 40
45 48
50

60
58

20

52

Hm

10
55

H ft

Hm

30

A 204

62%

B 150

20

53%

30

52

5048

45

40

20

35

H ft

10

4
10
10

l/min

6
100

50

l/s

10

12
200

150
2

0.3

0.1

0.2

0.4

0.1

0.2

12
200

14

3.8
1.2
1.0

0.8

0.6
0.4
0.2
0

25

25

20

20

15

10

10
2

g.p.m.
U.S.
g.p.m.20
00 U.S.

30

A 163

5040
55

50
60

A 167

10

10

60

70 100 80

64 66

40

18

90

30
35

NM440/16
40/16
NM4
67%

B 151

5
0

Q m3/h 2

16
14

64

20
20
15

30

40

50

50

54 56

10

60

12

70

80

72.075

14

90

NM4 40/20

B 195

25
60

40

A 204

66

C 137

0 U.S. g.p.m. 20

30

C 143

6
6

67

B 153

8
8

12

50

58%
56

54

40

50

12

H ft

Q m /h 2

72.074

Hm

15

H ftH ft

10

55

30
10

42

40

20
A350

300
B
5

0,6

0,4

0,2

0.8

1.0

0.6

0.8

Q m /h

l/s

l/min50

10
100

150

200

15
250
4

20
300

350

6
1.6

A
B

1.0

0.6
0.4

0.2

0.2

0.4

0
0

1.2

0.3
60
0.2
40
0.1
20
0

4
0,8

200

400

15
250

0
8
8

25
25

25

66

20
20

20

44

10
10

22

NPSHftft
NPSH

15
15

NPSH m

00

Qmm3/h/h
00 Q

10

10

20
15

30

72.076N
72.076

20

15

10
2

55
3

P HP

300

20

30
500

P kW

l/s

20

P HP

3
10
/h
Qm
l/min
100
200
3
5
10
m
/h
Q
l/min50
100
150

(%) P kW

P kW

0
2 0
0,60
0,50
0,4
0
0,3
0.7
0,2
0.6
0,1
0.50
80
0.4

P HP

10
0

00

40

5
0

Q m3/h

10

15

20

72.077

NPSH ft

10
12

NPSH m

HHmm

10
150

NPSHmm
NPSH

l/s

0.6

NPSH ft

6
100

P kW

P kW

0.2

4
50

l/min

0.8

0.4

3
Q m /h 2

1.0

0.5

0.3

NPSH m

3.6

0.4

0
0

P HP

3
Q m /h 2

NPSH ft

0
0

P HP

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


50

0 U.S. g.p.m.

100

A 251
B 247

NM4 40/25

50

70

150

200

40

60

30

B 162

Hm

H ft

30

10
2

10

10

m 3/h

Q l/min

100

0
30
500
4
A
3
B 2

20
200

300

400

2
C

1
0
60
40

0
1,5

10
200

20

30
400

40

50
800

600

0
2
1,5

0,6

0,3

0,5

0
80

60

(%)

A
B

40
20
0
9

10

Q m 3/h

0 U.S. g.p.m.

16

20

50

100

30

72.076N

150

B 200

12

C 188

3
0
0

Q m3/h 10

0 U.S. g.p.m.

20

50

30
100

72.076N

40
150

50

200

25

50

NM4 50/20

25
20
15
10
5
0

200

A 209

14

NPSH ft

25
20
15
10
5
0

NPSH m

0
9

m3/h

Q l/min

0,9

0
0

1,2

20

P kW

0
0

P HP

P kW

15
4

20

(%)

20

80

A 255

45

NM4 50/25

B 245

20

40

NPSH ft

Hm

40

10

NPSH m

25

50

15

35

NM4 50/16

A 174

10

20
C 227

100

12

80

H ft

U.S. g.p.m.

P HP

25

70

C 229

60

D 209

50

15

30
25

20

Hm

H ft

Hm

10

40

10

H ft

35

30

15

5
0
10
200

20

30
400

40

50
800

600

A
B

0,5

(%)

40

20

0
8

25

20
15

10

10
200

20

30
400

40

50
800

600

A
B

C
D

40

Q m3/h 10

20

30

40

72.076N

5
4
3
2

A
B

20

0
9
25
20
15
10
5
0

6
3

1
0

0
70
60

NPSH m

(%)

60

/h
Qm
l/min

0,5
0

0
80

NPSH m

1,5
1

0
0

NPSH ft

P kW

1,5

2,5
2

P kW

/h
Qm
l/min

10

P HP

0
0

P HP

2
0
2

20

10

50

41

Q m3/h 10

20

30

40

72.076N

50

NPSH ft

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


0

U.S. g.p.m.

100

150

200

250

300

0 U.S. g.p.m.

350

100

200

300

380

12

25

C 143

20

60 65

A 208

40

70

10

74
76%

60

10
5
0
0

30

/h
Qm
l/min

300

60
600

900

90
1500

1200

10

0
0

S
A

l/s

30
500

40

50

10

60
1000

70

15

80

90
1500

20

25
4

2
1

40

25

20
15

10

2
0

25

NPSH ft

0
8

NPSH m

20

30

Q m 3/h

0 U.S. g.p.m.

60

100

200

300

380

55 60

65

25

20
15

10

40

80

A 252

90

72.082N

5
0

20

Q m3/h

0 U.S. g.p.m.

NM4 65/25

30

40

100

A 321.5

60

50

60

80

300

90

380
120

NM4 65/31

64

69%

B 302

68

70

72.083

68

20

B 230

50

200

70

68

NPSH ft

(%)

80

NPSH m

20

l/min

Q m /h

60

0
0

P kW

P kW

20

P HP

30

65
74

15

50

70

B 193

Hm

B 153

H ft

Hm

15

30

H ft

A 165

NM4 65/20

35

NM4 65/16

P HP

S 175

10

100

68

30

60

70

C 278

64

80

H ft

50

60

72%

Hm

70

15

H ft

Hm

65

60

40

20

55

60

10

30
50

40

20

l/s

l/min

30
500

40

50

10

60
1000
15

70

80

20

25

P kW

25

20

NPSH ft

NPSH m

10

NPSH m

Q m3/h

20

30

40

50

60

70

80 72.084 90

50

10

60
1000
15

70

80

90
1500

20

25

12

10

8
6
2
0

3
2
1

5
0

l/min

40

15

l/s

30
500

4
2

20

Q m /h

0
0

10

P kW

10

90
1500

P HP

Q m /h

20

42

Q m3/h

20

30

40

50

60

70

80

72.087

90

12
10
8
6
4
2
0

NPSH ft

0
0

P HP

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


400
15
A 176

10

30

15
4
10

40
75

C 188

77%

73
70

0
0

/h
Qm
l/min

20
400

40

60
800

80

100
1600

1200

0
120
2000

5
4

20

0
0

3
2

60

3
Q m /h 20

l/min

l/s

40
500

60
1000

10

80

100

20

30

P kW

(%)

80
C

60

20
15

10

25

NPSH m

25

40

0 U.S. g.p.m.

200
60 65

A 264

80

60

300
70

100

400

500

120

72.085N

600

NM4 80/25

75

70

B 250
20
77%

C 231

75

60
73

50

H ft

70

15

40
10

30
20
3

0
0

Q m /h

l/s

l/min

50
500

100
1000

10

1500

150
2500

2000

20

30

40

A
6

10
8
6

P HP

4
2

25

20
15

10
2
0

NPSH ft

5
0

Q m3/h

50

100

72.088

25

20
15

10
0

80
73

Q m 3/h 20

0
8

NPSH ft

NPSH m

40

Hm

B
C

20

P kW

120
2000

1500

NPSH m

30
65

7
6

75

10

P HP

P kW

48

500

NM4 80/20

70

B 200

11

Hm

20

H ft

Hm

C 144

400

73

12

25

A 210

300

13

B 157

200
60 65

14

35

NM4 80/16

0 U.S. g.p.m.100

H ft

200

P HP

U.S. g.p.m.

0
150

43

5
0

Q m3/h 20

40

60

80

100

72.086

0
120

NPSH ft

12

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


400

500

600

700

70

140

S 331
A 320

NM4 80/315

A 413

B 295

Hm

C 277
80

1000

100
1500

150
2500

2000

P kW

B
C

10

58

10

45

0
0

Q m /h

l/s

l/min

50
500

100
1000

10

1500

B
C

150
2500

2000

20

30

40

A
B

P kW

20

40
30

C
20

10
10

S
0

40
10
8

25

20

30
20

10

NPSH m

50

NPSH ft

(%)

NPSH m

60

100

30

70

150
50

4
0
80

200

55

20

12

C 367

40

16

NMS4 80/400
60

50

180
3000

P HP

20

50

58

600

20

40
3

55

500

30

60

Q m /h 500
l/min

45 50

400

60%

50

20

0
0

300

B 390

100

30

10

200

60

120

Hm

40

0 U.S. g.p.m.

H ft

300

Q m3/h

10
2

50

100

150

15

P HP

200

180

44

5
0

Q m3/h

50

100

72.090

0
150

NPSH ft

0 U.S. g.p.m.

H ft

44

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


500

600

700

0 U.S. g.p.m. 200

A 265
50

80.5%
80

300

400

55 60 65 70

500

600

700

80

81%

60
77
75

15
30

70

80

75
73
70

900

NM4 100/25

40

C 185

800

80
75 77

B 250

20

77

Hm

25

NM4 100/20

77

B 202
10

800

50
70
65
60

10

40

H ft

400

60 65 70
73 75

A 219

15

300

Hm

200

H ft

0 U.S. g.p.m.

30

20
5

20
5

10

10

l/s

100
1500

1000

10

20

150
2500

2000

30

200

3000

40

50

P kW

P HP

10

150
2000

20

30

200
3000

40

50

60

A 12
B 10

6
4

25

25

20

20

10
2
0

40

NPSH ft

15

NPSH m

NPSH m

l/s

100

50

Q m3/h

100

0 U.S. g.p.m. 200

150

400
65

A 328

600

70 73

75

15

10
2

5
72.091

0
200

800

60

5
0

600

Hm

Hm

80

800

60

64

160

67

C 347

140

67

40
64

69%

20

65

180

68

73
70

200

NMS4 100/400
55

100

75

H ft

77%

400

B 377

50

C 286

150

A 405

B 306
30

100

0 U.S. g.p.m. 200

120

NM(S)4 100/315

50

Q m3/h

72.092

H ft

P kW

B
C

50
1000

l/min

Q m /h

10

5
4

0
0

60

120
100

30

60

80

40

Q m /h

l/s

50
1000

l/min
10

20

100

150
2000

30

3000
40

50

10

25

20
15

Q m3/h

50

100

150

72.093

200

NPSH m

10

NPSH ft

NPSH m

30

20

150
2000

30

200
3000

40

50

60

A
B
C

20

30

25

20
15

10
0

45

40

10

50

20
10

20

10

100

30

5
0

l/s

50
1000

40

10

10

0 m3/h
Q
0 l/min
0

60

20

P kW

20

200

P kW

0
0

P HP

10

P HP

50

l/min 500

NPSH ft

Q m /h

P HP

0
0

5
0

Q m3/h

50

100

150

72.094

200

NPSH ft

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


0 U.S. g.p.m.

400
60

A 271
20

600
70 74

800

1000

1200

1400

40

80
78

0 U.S. g.p.m.

NM(S)4 125/250

80%

400

A 330

600
60

70

800
74

1000

1200

NMS4 125/315

78

B 310

B 252

30

60

78

C 237

1400

78

100

80%

C 295

74

74
70

E 203

40

60

Hm

Hm

D 220

H ft

15

120

70

80

60

60

20

H ft

25

10
40
10

20
5

20

Q m /h

l/s

100

l/min 1000

200
3000

2000

20

40

60

300
5000

4000

80

10

80
40

20

30

C
20

4
10

NPSH m

8
20

NPSH ft

NPSH m

60

20

6
4

10
2

100

Q m3/h

500

72.095

300

1000
60

A 405

60

200

65

70

73

B 380

1500

200

NMS4 125/400
75

76%

180
75

50

73

160

C 364

70

140
40
66

H ft

0 U.S. g.p.m.

Hm

40

300
5000

10

120
100

30
60

80
3
Q m /h 50

l/s 10

100

l/min 1000
20

150
2000

30

40

200
3000
50

250
4000
60

70

300
5000
80

350
5800
90

50

B
C

40
30

80
60
40

P HP

0
0

60

P kW

20

4000

10

20
20

10

20

6
4

10

NPSH ft

NPSH m

l/s

200
3000

2000

P kW

B
C

10

2
0

100

l/min 1000

20
P HP

P kW

20

Q m /h

30

18

0
0

P HP

0
0

Q m3/h 50

100

150

200

250

300

72.097

0
350

46

Q m3/h

100

200

300

72.096

NPSH ft

NM4, NMS4

Close Coupled Centrifugal Pumps

Characteristic curves n 1450 rpm


1000
60 65 70
75

A 330

80

100

70 74

1500

2000

81%
80

C 370

75
65

60

150

77

80

70

20

73

40

70

100

30

60

200

NMS4 150/400

77

B 390

50

Hm

Hm

1000
60 65

80

80

C 290
D 278

500

A 415

60

120

NMS4 150/315
82%

B 310

30

0 U.S. g.p.m.

2000

H ft

0 U.S. g.p.m.

H ft

40

40

65

10

60
20

20

50

l/s

100
2000

l/min
20

40

200
3000
4000
60

300
5000
80

6000

400
7000

100

500
8000

A 50
B

40

20

30

l/s

100
2000

l/min
20

40

200
3000
4000
60

300
5000
80

6000

400
7000

100

500
8000

120

A 100
B
C

40

50

20

10

20

10
0

25

10

20
15

10
2

NPSH m

Q m /h

60

P kW

30

0
0

80

NPSH ft

P kW

10

120

40

NPSH m

0
30
20

5
10

5
0

Q m3/h

100

200

300

400

P HP

Q m /h

72.098

0
500

47

Q m3/h

100

200

300

400

72.099

0
500

NPSH ft

0
0

P HP

NM4

Close Coupled Centrifugal Pumps

Dimensions and weights


1
fM
a

l1
DN2

l2

DN2

h2
DN1

H
g1 h1
4.93.098

m2

n3

m1
w

Standard construction

n1

mm

DN1 DN2
DN1

NM4

Picture

b
n2

kg
a

ISO 228

fM

h1

h2

m1 m2

n1

n2

n3

NM4 25/12A/A
56 313 90 140 199 37,5 27,5 170 130 9
G 11/2 G 1 56 380 100 160 228 37,5 27,5 190 150 30
NM4 25/160AE-BE
NM4 25/200A/B-B/A-C/A
63 385 125 180 253 45 32,5 245 200 49

l1

l2

38 9,5 85 88 250 10
38 9,5 102 102 250 10
45 11,5 125 125 250 11

13,5
17,5
27-23-21,5

fM

l2

l1

fM

a
DN2

DN2

l1

l2
DN2

DN2

A
g2*

DN1

DN1

h2

h2
A

h1

g1 h1

4.93.061.2

g2

4.93.078.1

n3

m2

m2
m1

m5

b1

w1

m4

n1

s1

n2

m1

h4

n2
n1

n5

m4 m5 g1

g2

Standard construction
mm
kg

NM4

Picture

DN1 DN2

2
3
2
3

h1

h2

h4

132
160
132
160

160
180
160
180

m1 m2

n1

n2

n3

n5

w1

b1

s1

l1

l2

240
240
240
265

190
190
190
212

32 80
32 80
40 80
40 100

410
410
410
470

260
288
268
288

100
100
100
100

47
62
47
62

50
50
50
50

--

14
14
14
14

120
140
119
140

120
140
119
140

255
255
255
255

12
12
12
12

30,5-30
38-34,5
37-33-31
41-40,5

NM4 40/25B/B-C/B
NM4 40/25A/B

65

40 100

495
308
180 225
525
340

125 95 320 250 60

65

14

175 175

300
330

15

66,5-62
78

NM4 50/16A/B-B/B

65

50 100 470 160 180 288

100 70 265 212 62

50

14

127 141 255

12

40-39,5

62
100 70 265 212
60

265
140 153
310

14

44,5
57-52,5

15

68
85,5-78

32/16AE-BE
32/20A/A-BE
40/16A/B-B/A-C/A
40/20A/A-B/A

70
70
70
70

65

480
50 100
160 200 288
505

NM4 50/25C/B-D/A
NM4 50/25A/B-B/B

65

490
308
50 100
180 225
530
340

125 95 320 250 60

65

14

300
175 175
330

NM4 65/16B/B-C/B
NM4 65/16A/B-S

80

65 100

470
160 200 288
495

125 95 280 212

62
60

65

14

150 172

255
300

15

48-48
54,5-55

NM4 65/20B/A
NM4 65/20A/A

80

65 100

505
308
180 225
525
340

125 95 320 250 60

65

14

155 175

310
330

15

61
73,5

80

65 100

360
385

160 120 360 280 60

80

18

175 190

80

65 125

225 280 410

160 120 400 315 75

NM4 50/20C/B
NM4 50/20A/B-B/B

fM

50
50
65
65

NM4
NM4
NM4
NM4

NM4 65/25B/A
NM4 65/25A/B
NM4 65/31C/B
NM4 65/31A/B-B/B
NM4 80/16C/B
NM4 80/16A/B-B/B
NM4 80/20C/A
NM4 80/20A/A-B/A
NM4 80/25C/A
NM4 80/25B/B
NM4 80/25A/B
NM4 80/31C/B
NM4 80/31A-B
NM4 100/20B/A-C/A
NM4 100/20A/B

100

80 125

100

80 125

100

80 125

100
100

80 125
80 125

125 100 125

540
645
670
745
495
520
540
560
565
670
745
745
787
565
665

200 250

180 225
180 250
200 280
250 315
260 315
200 280

288
- 125
308
308
- 125
340
360
385 - 160
385
435 - 160
466 10 160
360
- 160
385

14

80

18

220 220

62
95 320 250
60

65

14

165 193

95 345 280 60

65

14

170 194

120 400 315 60

80

18

191 210

80
80

74

18
18

18

120 400 315 90


120 400 315 - 254 20
120 360 280 60

80

160 120 400 315 75

80

18

80

74

18

80

18

80

74

18

NM4 100/25A/B-B/B

125 100 140 760 225 280 410

NM4 100/31B-C
NM4 125/25E/B
NM4 125/25C/B-D/B
NM4 125/25A-B

125 100 140 802 260 315 466 10 160 120 400 315 - 254 20
685
150 125 140
250 355 435 - 160 120 400 315 90
735
150 125 140 802 260 355 466 10 160 120 400 315 - 254 20

50

48

- 220 232
14 220 232

345
18
405
405
20
465
255
15
300
320
15
340
335
335 20
465
465 20
147 435 395 330
20
400

180 212

205 233 465

6
-

97
116
164-153
176
53
65,5-61
74,5
91-82
102
124
135
181
269-248
99-90
109

20

152-143

14 230 250 147 435 395 405


20
- 235 268
465
14 235 268 147 435 395 -

280-261
149
173-161
261-243

NM4

Close Coupled Centrifugal Pumps

Dimensions and weights


1
AG
fM

AS
l1

l2

a
DN2

h2

DN1

g1

h1

4.93.083.1

m2

n3

m1

n2
n1

mm
Picture

kg

NM4
DN 1 DN 2

fM

AG

AS

h1

h2

m1

m2

n1

n2

n3

l1

l2

g1

190
190
190
190

105
105
105
105

132
160
132
160

160
180
160
180

418
446
418
446

120
140
119
140

50
50
65
65

32
32
40
40

80
80
80
100

440
440
440
470

100
100
100
100

70
70
70
70

240
240
240
265

190
190
190
212

47
62
47
62

50
50
50
50

14
14
14
14

120
140
119
140

255
255
255
255

12
12
12
12

NM4 EI 40/25B/B-C/B
NM4 EI 40/25B/B-C/B
NM4 EI 40/25A/B

65

40

100

495 190 105


474
495 190 105 180 225 474 125
525 210 118
502

95

320 250

60

65

14

300
175 175 300
330

15

NM4 EI 50/16A/B-B/B

65

50

100

470 190 105 160 180 446 100

70

265 212

62

50

14

127 141 255

12

100

480 190 105


446
505 190 105 160 200 454 100
505 190 105
454

265 212

62
60
60

14

265
140 153 310
310

95

320 250

60

65

14

300
175 175
330

15

NM4 EI
NM4 EI
NM4 EI
NM4 EI

32/16AE-BE
32/20A/A-BE
40/16A/B-B/A-C/A
40/20A/A-B/A

NM4 EI 50/20C/B
NM4 EI 50/20B/B
NM4 EI 50/20A/B-B/B

65

50

70

50

14

NM4 EI 50/25C/B-D/A
NM4 EI 50/25A/B-B/B

65

50

100

474
490 190 105
125
180 225
530 210 118
502

NM4 EI 65/16B/B-C/B
NM4 EI 65/16A/B
NM4 EI 65/16S

80

65

100

470 190 105


446
495 190 105 160 200 454 125
495 190 105
454

95

280 212

62
60
60

65

14

255
150 172 300
300

15

NM4 EI 65/20B/A
NM4 EI 65/20A/A

80

65

100

505 190 105


474
180 225
125
525 210 118
502

95

320 250

60

65

14

155 175

310
330

15

NM4 EI 65/25B/A
NM4 EI 65/25A/B
NM4 EI 65/31C/B
NM4 EI 65/31A/B-B/B
NM4 EI 80/16C/B
NM4 EI 80/16A/B-B/B
NM4 EI 80/16A/B-B/B
NM4 EI 80/20C/A
NM4 EI 80/20A/A-B/A
NM4 EI 80/25C/A
NM4 EI 80/25B/B
NM4 EI 80/25A/B
NM4 EI 80/31C/B
NM4 EI 100/20B/A-C/A
NM4 EI 100/20A/B
NM4 EI 100/25A/B-B/B
NM4 EI 125/25E/B
NM4 EI 125/25C/B-D/B

80

65

100

80

65

125

100

80

125

100

80

125

100

80

125

100

80

125

125

100

125

125

100

150

125

540
645
670
745
495
520
520
540
560
565
670
745
745
565
665

210
281
281
281
190
190
190
190
210
210
281
281
281
210
281

118
153
153
153
105
105
105
105
118
118
153
153
153
118
153

522
200 250
160 120 360 280
593
225 280 618 160 120 400 315
180 225
180 250
200 280
250 315

466
474
474
474
502
522
593
593
613
522
593

60

80

18

175 190

75

80

18

220 220

65

14

165 193

125

95

320 250

62
60
60

125

95

345 280

60

65

14

170 194

160 120 400 315

60

80

18

191 210

345
405
405
465
255
300
300
320
340
335
335
465
465
330
400

18
20
15
15
20

160 120 400 315

90

80

18

220 232

160 120 360 280

60

80

18

180 212

140

760 281 153 225 280 618 160 120 400 315

75

80

18

205 233 465

20

140

685 281 153


250 355 643 160 120 400 315
735 281 153

18

405
235 268
465

20

200 280

49

90

80

20
20

36,9-36,4
44,4-40,9
43,4-39,4-37,4
47,4-46,9
68,4
72,9
85,5
46,4-45,9
50,9
58,9
63,4
74,4-74,4
93,0-85,5
54,4-54,4
60,9
61,4
67,4
81,0
104,5
130,8
178,8-167,8
190,8
59,4
67,4
71,9
80,9
98,5-89,5
109,5
138,8
149,8
195,8
106,5-97,5
123,8
166,8-157,8
163,8
187,8-175,8

NMS4

Close Coupled Centrifugal Pumps

Dimensions and weights


4
fM
l1

l2
DN2

DN1

DN2

h2
H

A
h1
g2

4.93.466.1

m2
m1

s1

b
w

m5
m4

b1

w1

n5

n2
n1

Standard construction
mm
Picture

DN1 DN2

kg

NMS4
NMS4 80/315S
NMS4 80/400C/A
NMS4 80/400B/A
NMS4 80/400A/A
NMS4 100/315A/A
NMS4 100/400C/A
NMS4 100/400B/A
NMS4 100/400A/A
NMS4 125/315C/A
NMS4 125/315B/A
NMS4 125/315A/A
NMS4 125/400C/A
NMS4 125/400B/A
NMS4 125/400A/A
NMS4 150/315D/A
NMS4 150/315C/A
NMS4 150/315B/A
NMS4 150/315A/A
NMS4 150/400C/A
NMS4 150/400B/A
NMS4 150/400A/A

100
125
125
125
125
125
125
125
150
150
150
150
150
150
200
200
200
200
200
200
200

80
80
80
80
100
100
100
100
125
125
125
125
125
125
150
150
150
150
150
150
150

fM

h1

h2

125
125
125
125
140
140
140
140
140
140
140
140
140
140
160
160
160
160
160
160
160

969
974
1025
1025
984
1040
1040
1139
989
1040
1040
1139
1199
1307
1009
1060
1060
1159
1219
1277
1280

250
280
280
280
250
280
280
280
280
280
280
315
315
315
280
280
280
280
315
315
315

315
355
355
355
315
355
355
355
355
355
355
400
400
400
400
400
400
400
450
450
450

511
542
542
580
512
542
580
605
542
542
580
640
640
707
542
542
580
605
640
707
747

m1 m2

n1

n2

n5

w1

b1

s1

l1

l2

160
160
160
160
160
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200

400
435
435
435
400
500
500
500
500
500
500
500
500
500
550
550
550
550
550
550
550

315
355
355
355
315
400
400
400
400
400
400
400
400
400
450
450
450
450
450
450
450

279
279
279
318
279
279
318
356
279
279
318
356
356
406
279
279
318
356
356
406
457

25
25
25
25
25
25
25
55
25
25
25
25
25
25
25
25
25
55
25
25
45

80
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

78
70
70
83
70
70
83
103
70
70
83
103
103
100
70
70
83
103
103
100
100

18
18
18
18
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22

15
15
15
19
15
15
19
19
15
15
19
19
19
24
15
15
19
19
19
24
24

220
268
268
268
230
268
268
268
247
247
247
280
280
280
260
260
260
260
295
295
295

232
268
268
268
250
280
280
280
278
278
278
305
305
305
298
298
298
298
328
328
328

340
318
318
334
312
318
334
384
318
318
334
409
409
454
318
318
334
384
409
404
432

120
120
120
120
120
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150

Flanges EN 1092-2

DG

DN
DK
DE

4.93.094

mm

DN DG DK DE

Holes

N
32

76

100 140

19

18

40

84

110 150

19

18

50

99

125 165

19

20

65

118 145 185

19

20

80

132 160 200

19

22

100 156 180 220

19

24

125 184 210 250

19

24

150 211 240 285

23

26

200 266 295 340

23

30

50

m4 m5

g2

382
435
435
455
382
435
455
460
435
435
455
461
461
461
435
435
455
460
461
461
535

6
6
6
6
6
6
6
8
6
6
6
8
8
8
6
6
6
8
8
8
6

432
520
520
540
432
520
540
540
520
520
540
540
540
540
520
520
540
540
540
540
625

339
355
413
308
366
419
506
331
350
409
524
665
349
374
421
501
594
681
845

B-NM4

Close Coupled Centrifugal Pumps

Dimensions and weights


1
fM
a

l1
DN2

l2

DN2

h2
DN1

H
g1 h1
4.93.098

m2

n3

m1

b
n2

n1

Bronze construction B-NM4


mm

DN1 DN2
DN1

B-NM4

Picture

kg
a

ISO 228
1

fM

h1

h2

m1 m2

n1

n2

n3

B-NM4 25/160AE-BE
56 380 100 160 228 37,5 27,5 190 150 30
G 11/2 G 1
B-NM4 25/200A/B-B/A-C/A
63 400 125 180 253 45 32,5 245 200 49

l1

l2

38 9,5 102 102 250 10


45 11,5 125 125 250 11

19-19
29-25-23

2
fM

fM
l1

l2

DN2

l1

DN2

l2
DN2

DN2

A
g2*
DN1

DN1

h2

h2

g1

h1
h1

4.93.083.1

m2

n3

m1

m2
m1

n2
n1

g2

4.93.078.1

h4

s1

m5

b1

w1

n2
n1

m4

n5

Bronze construction B-NM4


mm
Picture

B-NM4

kg
DN1 DN2

fM

h1

h2

132
160
132
160

160
180
160
180

260
288
260
288

h4 m1 m2

n1

n2

n3

n5

w1

b1

s1

l1

l2

w4

100
100
100
100

240
240
240
265

190
190
190
212

47
62
47
62

50
50
50
50

14
14
14
14

120
140
119
140

120
140
119
140

255
255
255
255

65

54
60

14

10
12

50

14

65

54
60

14

10
12

175 175

156 205 175


125 280 250

65

14

150 172

255
300

B-NM4 32/16A-B
B-NM4 32/20A/A-B
B-NM4 40/16A/A-B-C
B-NM4 40/20A/A-B/A

50
50
65
65

32 80
32 80
40 80
40 100

410
410
410
470

B-NM4 4025/B/B-C/B
B-NM4 4025/A/B

65

40 100

535
318
10 125 95
190 225
560
350

B-NM4 50/16A/A-B/A

65

50 100 470 160 180 288

B-NM4 5025/C/B-D/A
B-NM4 5025/A/B-B/B

65

50 100

535
318
10 125 95
190 225
560
350

B-NM4 65/16B/B-C/B
B-NM4 65/16A/B-S

80

65 100

470
288
160 200
495
306

70
70
70
70

320 250

100 70 265 212 62


320 250

125 95 280 212

51

62
60

140
15
190
-

140
15
190
-

175 175

w5 g1
-

156 205 175


125 280 250

127 141 255

g2

12
12
12
12

38-38
45-41
43-40-38
55-55

73-73
89

12

55-55

79,5
105-92

15

63-63
71-71

B-NMS4

Close Coupled Centrifugal Pumps

Dimensions and weights


4

fM
l1

l2
DN2

DN1

DN2

h2
H

A
h1

m2
m1

g2

4.93.466.1

s1

b
w

m5
m4

b1
n5

n2
n1

w1

Bronze construction B-NM4

Picture

mm

B-NMS4
DN1 DN2

B-NMS4 80/315A/A-B/A
B-NMS4 80/315S
B-NMS4 80/400C/A
B-NMS4 80/400B/A
B-NMS4 80/400A/A
B-NMS4 100/315B/A-C/A
B-NMS4 100/315A/A
B-NMS4 100/400C/A
B-NMS4 100/400B/A
B-NMS4 100/400A/A
B-NMS4 125/250A/A-B/A
B-NMS4 125/315C/A
B-NMS4 125/315B/A
B-NMS4 125/315A/A
B-NMS4 125/400C/A
B-NMS4 125/400B/A
B-NMS4 125/400A/A
B-NMS4 150/315D/A
B-NMS4 150/315C/A
B-NMS4 150/315B/A
B-NMS4 150/315A/A

100
100
125
125
125
125
125
125
125
125
150
150
150
150
150
150
150
200
200
200
200

80
80
80
80
80
100
100
100
100
100
125
125
125
125
125
125
125
150
150
150
150

fM

h1

h2

m1

m2

n1

n2

n5

w1

b1

s1

l1

l2

125
125
125
125
125
140
140
140
140
140
140
140
140
140
140
140
140
160
160
160
160

948
969
974
1025
1025
963
984
1040
1040
1139
951
989
1040
1040
1139
1199
1307
1009
1060
1060
1159

250
250
280
280
280
250
250
280
280
280
250
280
280
280
315
315
315
280
280
280
280

315
315
355
355
355
315
315
355
355
355
355
355
355
355
400
400
400
400
400
400
400

457
511
542
542
580
457
512
542
580
605
457
542
542
580
640
640
707
542
542
580
605

160
160
160
160
160
160
160
200
200
200
160
200
200
200
200
200
200
200
200
200
200

120
120
120
120
120
120
120
150
150
150
120
150
150
150
150
150
150
150
150
150
150

400
400
435
435
435
400
400
500
500
500
400
500
500
500
500
500
500
550
550
550
550

315
315
355
355
355
315
315
400
400
400
315
400
400
400
400
400
400
450
450
450
450

254
279
279
279
318
254
279
279
318
356
254
279
279
318
356
356
406
279
279
318
356

20
25
25
25
25
20
25
25
25
55
20
25
25
25
25
25
25
25
25
25
55

80
80
80
80
80
80
80
100
100
100
80
100
100
100
100
100
100
100
100
100
100

60
78
70
70
83
60
70
70
83
103
60
70
70
83
103
103
100
70
70
83
103

18
18
18
18
18
18
18
22
22
22
18
22
22
22
22
22
22
22
22
22
22

15
15
15
15
19
15
15
15
19
19
15
15
15
19
19
19
24
15
15
19
19

220
220
268
268
268
230
230
268
268
268
235
247
247
247
280
280
280
260
260
260
260

232
232
268
268
268
250
250
280
280
280
268
278
278
278
305
305
305
298
298
298
298

271
340
318
318
334
271
312
318
334
384
259
318
318
334
409
409
454
318
318
334
384

Flanges EN 1092-2
mm

DG
DN DG DK DE

Holes

N
W

4.93.094

DN

32

76

100 140

19

18

DK

40

84

110 150

19

18

DE

50

99

125 165

19

20

65

118 145 185

19

20

80

132 160 200

19

22

100 156 180 220

19

24

125 184 210 250

19

24

150 211 240 285

23

26

200 266 295 340

23

30

52

NM4

Close Coupled Centrifugal Pumps

Features

Cutting edge hydraulics


The geometry of the impeller and the pump casing are optimized to achieve maximum efficiency
and the best suction capability.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic parts in contact
with the pumped liquid allows NM4 series pumps to be selected for use with different types of
liquids.

Compact Design
The compact design allows for easy installtion even in confined spaces.

Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection to the end
user whilst allowing for inspection of the mechanical seal.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability under all operating conditions.

53

NMS4

Close Coupled Centrifugal Pumps

Features

Cutting edge hydraulics


The geometry of the impeller and the pump casing are optimized to achieve maximum efficiency and
the best suction capability.

Flexibility
The option to choose between cast iron and bronze materias for the hydraulic parts in contact with
the pumped liquid allows NMS4 series pumps to be selected for use with different types of liquids.

New lantern bracket construction


The lantern brackets incorporate a thrust bearing on the hydraulic side which guarantees the elimination of additional loads on the motor bearings. The flange is sized to be used with standard motors
B35.

Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection to the end user
whilst allowing for inspection of the mechanical seal.

Simplified motor maintenance


The presence of the thrust bearing on the hydraulic side makes it easier to remove the motor, facilitating maintenance operations and eliminating the risks of damage to the hydraulic parts.

54

09/2016

N, N4

End-Suction Centrifugal Pumps


standardized EN 733
Construction
Single-stage end-suction centrifugal pumps, with bearing
bracket.
Nominal duty points and main dimensions in accordance with
EN 733. Back Pull-Out construction, for simple and quick
dismantling and reassembly.
N, N4: version with pump casing and lantern bracket in cast iron.
B-N, B-N4: version with pump casing and lantern bracket in bronze.
(the pumps are supplied fully painted).
Rated speed of rotation (50 Hz):

N 2900 rpm.
N4 1450 rpm.

Connections: PN 10 flanges EN 1092-2.


Counter-flanges (on request)
Sizes
Flanges
from 32-160 to 50-250
Screwed flanges PN 16 EN 1092-1
from 65-125 to 150-400 Flanges for welding
PN 10 EN 1092-1
Shaft sealing
Standardized mechanical seal in accordance with ISO 3069.
Stuffing box seal (on request).

Applications
For clean liquids, without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For water supply.
For heating, air conditioning, cooling and circulation plants.
For civil and industrial applications and for agriculture.
For fire fighting applications.
For irrigation.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar (16 bar for
N,N4 65/125, N,N4 65/160 and N,N4 80/160).
Maximum permissible rotation speed: see table on page 68.

Pump-Motor unit
The electropumps N, B-N, N4, B-N4 series comply with the European
Regulation no. 547/2012.

Materials
Components
Pump casing
Casing cover
Impeller

Shaft
Shaft sleeve
Mechanical seal
Counter-flanges

N, N4
N, N4
B-N, B-N4
Mechanical seal
Stuffing box
Mechanical seal
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
For 32-125, 32-160, 32-200, 40-200
Chrome steel
Cr-Ni-Mo steel
Carbon steel
1.4104 EN 10088
1.4401 EN 10088
C
40
UNI
7845
(AISI 430)
(AISI 316)
Bronze
_
_
G-Cu Sn5 Zn5 Pb5 EN 1982
with chromate surface
_
Carbon - Ceramic - NBR
Carbon - Ceramic - NBR
Steel Fe 430B UNI 7070

55

N,N4 pump connected to a standard electric motor in B3


construction form (EN 60072-1), by means of a baseplate,
driven by a flexible coupling and with coupling protection.
Three-phase 400 V , 50 Hz
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from 7,5 kW.
IP 55 protection.
Motor suitable for operation with frequency converter.

Special features on request


- Special mechanical seal.
- Chrome-nickel steel AISI 316 pump-shaft.
- Higher or lower liquid or ambient temperatures.
- Other motor protection.
- Motor for other voltage.
- Frequency 60 Hz (as per 60 Hz data sheet).

End-Suction Centrifugal Pumps


standardized EN 733

Coverage chart n 2900 rpm


20

30
30

40
40

Imp. g.p.m.

50

50

U.S. g.p.m.

100

200

100

300

200

300

400

400

500

1000

500

1000

2000

130

400

100

300

H
m

N 40-250

N 65-250

N 50-250

N 80-250

N 100-250

200

50
40

N 32-200

N 40-200

N 32-160

N 40-160

N 50-200

ft

N
80-200

N 65-200

N 100-200

30

N 50-160

100
90
80
70
60

N 65-160
N 80-16

20
N 32-125

N 65-125

N 40-125

50

N 50-125

40
10

30

20
5

100

9 10
150

m 3/h

Q l/min

20
300

30
400

40

50

500

100
1000

200
2000

3000

300

400

4000 5000

500
8000

72.844.N

Tolerances according to UNI EN ISO 9906:2012

Performance n 2900 rpm


PUMP
POMPA

MOTOR
MOTORE

P2
kW

B-N 32-125F/A
B-N 32-125D/A

N 32-125F/A
N 32-125D/A

71 M2

0,55

B-N 32-125A/A

N 32-125A/A

80 M2
80 M2
80 M2
90 S2

0,75
1,1
1,1
1,5

PUMP
POMPA

Q m3/h
Q l/min

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

27

30

33

37,8

39

42

45

48

110

125

140

160

180

200

220

250

280

315

350

400

450

500

550

630

650

700

750

800

12,5

12,5

12

11,5

11

10,5

9,5

0,4

0,43

0,46

0,48

0,5

0,52

0,54

0,55

0,56

18

18

17,5

17

16,5

16

15,5

14

12,5

11

8,5

0,63

0,67

0,7

0,75

0,79

0,83

0,86

0,9

0,93

0,95

0,97

23

23

22,5

22

21,5

21

20,5

19,5

18

16

14

10

0,83

0,87

0,91

0,96

1,01

1,06

1,1

1,19

1,26

1,31

1,35

1,38

22,5

B-N 32-125S/A

N 32-125S/A

90 S2

1,5

23,5

23,5

23

22

21,5

21

20,5

0,86

0,9

0,94

1,06

1,12

1,17

1,25

B-N 32-160B/A

N 32-160B/A

29,5

29

28,5

27,5

27

26

N 32-160A/A

1,5
2,2
2,2
3
2,2
3

29,5

B-N 32-160A/A

90 S2
90 L2
90 L2
100 L2
90 L2
100 L2

B-N 32-200D/A

N 32-200D/A

19

18,5

1,3

1,36

1,42

1,49

25*

22,5*

20*

17,5*

12,5*

1,55

1,63

1,1

1,17

1,23

1,30

1,37

1,43

1,7

1,75

35,5

35

34,5

34

33,5

33

32*

30*

28*

25*

21*

15*

1,64

1,71

1,81

1,9

1,98

2,05

2,16

2,24

2,33

2,4

2,47

2,5

37,5

37

36

35

34

33

32

30

27

22

1,92

2,06

2,17

2,24

2,3

2,35

2,4

2,45

2,5

1,56

N 32-200C/A

100 L2

44,5

44

43,5

40

38,5

36

32

2,17

2,28

2,36

2,5

2,63

2,74

2,83

2,97

3,1

3,2

N 32-200A/A

112 M2
132 S2

4
5,5

57

56,5

56

55,5

54,5

53,5

52,5

51

49

2,9

3,1

3,18

3,35

3,51

3,67

3,8

B-N 40-125C/A
B-N 40-125A/A

N 40-125C/A
N 40-125A/A

80 M2
90 S2
90 L2

4,4

Hm

13

12

11

9,5

0,96

1,00

1,04

1,07

1,10

1,13

1,13

1,13

P3 kW

17,5

17

16,5

16

15

13,5

12

10,5

7,5

6,5

1,21

1,26

1,32

1,38

1,44

1,49

1,53

1,56

1,57

1,57

22

22

21,5

21

20

19

18

16,5

14

13

11,5

1,50

1,57

1,65

1,72

1,82

1,91

1,98

2,04

2,10

2,11

2,13

2,2

23

22,5

22

21,5

20

18,5

16,5

14,5

11

10

1,55

1,63

1,72

1,80

1,90

1,99

2,06

2,12

2,17

2,17

29

28,8

28

27,5

26,5

25

23,5

21,5

18

17

2,08

2,18

2,30

2,41

2,55

2,67

2,78

2,87

2,97

2,99

3,02

37

36,5

36,5

36

35

33,5

32

30,5

27

26

23,5

20

17

2,70

2,84

3,01

3,18

3,35

3,53

3,72

3,84

4,01

4,05

4,12

4,20

4,22

39

38

37

35,5

33,5

30,5

27

22,5

14

3,66

4,18

4,30

4,43

1,1
1,5
2,2

B-N 40-160B/A

N 40-160B/A

100 L2

B-N 40-160A/A

N 40-160A/A

B-N 40-200D/A

N 40-200D/A

B-N 40-200C/A

N 40-200C/A

112 M2
132 S2
112 M2
132 S2
112 M2
132 S2
132 S2
132 S2
132 S2
132 S2

4
5,5
4
5,5
4
5,5
5,5
7,5
5,5
7,5

132 S2

7,5

B-N 40-200A/A

N 40-200A/A

B-N 40-250C/A

N 40-250C/A

160 M2

11

B-N 40-250B/A

N 40-250B/A

160 M2

11

B-N 40-250A/A

N 40-250A/A

160 M2

15

Standard construction.

B-N

Bronze construction.

46

4,2

13,5

90 L2

N 40-200B/A

41

N 40-160C/A

B-N 40-200AR/A N 40-200AR/A

42

1,79

14

B-N 40-160C/A

B-N 40-200B/A

43

1,48

B-N 32-200A/A

N 40-125F/A

13

35,5

B-N 32-200C/A

B-N 40-125F/A

16,5

P2 Rated motor power output.

P3 Pump power input.

56

3,20

3,35

3,51

3,86

4,03

41,5

40,5

39,5

38

36

33,5

3,44

3,59

3,78

3,95

4,15

4,32

50

14

49,5

48,5

47,5

45,5

43,5

41,5

37,5

30,5

3,96

4,18

4,41

4,64

4,92

5,17

5,39

5,60

5,87

55

54,5

54

53

51

49

4,50

4,70

5,07

5,30

5,65

5,95

57,5

57

56,5

55,5

54,5

52,5

48

42,5

40,5

4,78

5,04

5,34

5,63

6,03

6,40

6,70

7,01

7,34

7,43

7,62

61

61

60,5

59,5

58,5

56,5

53,5

49,5

41,5

40

33,5

50,5

35

5,86

6,16

6,49

6,82

7,28

7,72

8,07

8,48

69,5

69,5

69

68,5

67

65,5

63,5

60,5

53,5

51

45

6,87

7,19

7,56

7,91

8,47

8,91

9,35

9,75

10,40

10,54

10,93

83

77,5

90

90

89,5

89

88,5

87

85

9,31

9,73

10,21

10,68

11,34

11,98

12,60

H Total head in m.

9,02

13,19 14,00

9,15

9,35

76

70,5

14,21

14,65

* Maximum suction lift 1-2 m.

End-Suction Centrifugal Pumps


standardized EN 733

Performance n 2900 rpm


POMPA
PUMP

POMPA
PUMP

B-N

B-N 50-125F/A

N 50-125F/A

B-N 50-125D/A

N 50-125D/A

MOTORE
MOTOR

P2
kW

90 L2

2,2

100 L2

Q m3/h
Q l/min

24

27

30

33

37,8

42

48

54

60

66

69

72

75

78

81

84

96

400

450

500

550

630

700

800

900

1000

1100

1150

1200

1250

1300

1350

1400

1600

15,5

15

14

13,5

12

10

1,87

1,93

2,02

2,09

2,14

2,18

2,14

2,10

20

19,5

18,5

18

16,5

14,5

13

10,5

2,5

2,58

2,7

2,81

2,91

2,96

2,98

2,92

2,9

2,87

24

24

23

22,5

21

19,5

17,5

15

14

12,5

11,5

10

3,11

3,22

3,39

3,54

3,69

3,78

3,85

3,87

3,86

3,84

3,81

3,79

16,5

15,5

B-N 50-125A/A

N 50-125A/A

112 M2

B-N 50-125S/A

N 50-125S/A

112 M2
132 S2

4
5,5

26,5

26

25,5

24,5

23,5

22

20

18

13

11

3,38

3,52

3,71

3,87

4,04

4,18

4,25

4,29

4,29

4,28

4,26

4,24

4,22

31

30,5

29,5

28

26

24

21,5

19

17,5

15,5

13,5

11,5

9,5

4,30

4,48

4,71

4,90

5,11

5,28

5,35

5,22

B-N 50-160B/A

N 50-160B/A

132 S2

5,5

B-N 50-160A/A

N 50-160A/A

132 S2

7,5

Hm

48

47,5

5,81

14

5,40

5,40

5,36

5,32

5,30

38,5

38

37,5

36,5

34,5

32,5

30

27

25,5

24

22,5

20,5

19

5,44

5,67

6,02

6,31

6,67

6,95

7,18

7,30

7,34

7,38

7,41

7,42

7,46

47,5

47

45,5

44,5

42,5

40

37

33

30,5

28

25,5

23

6,73

7,18

7,55

8,02

B-N 50-200B/A

N 50-200B/A

160 M2

11

6,13

6,44

B-N 50-200A/A

N 50-200A/A

160 M2

11

55

55

54,5

54,5

53,5

52

50

48

45

41,5

39,5

37

35

32,5

6,92

7,29

7,65

7,99

8,56

8,99

9,57

10,05

10,45

10,75

10,89

10,98

11,11

11,15

B-N 50-200S/A

N 50-200S/A

160 M2

15

60

59,5

59,5

58,5

57,5

55,5

53,5

50,5

47

45

43

40,5

37

7,56

7,98

8,39

8,79

9,38

9,82

10,48

11,05

11,54

11,85

12,02

12,20

12,30

12,40

55

54,5

54

53

51,5

49,5

46,0

41,5

35,5

28,5

24,5

9,99

10,42

10,75

10,95

P3 kW

60

8,43

8,77

B-N 50-250C/A

N 50-250C/A

160 M2

11

7,28

B-N 50-250B/A

N 50-250B/A

160 M2

15

69

68,5

68

67,5

66

64

61

57

52,5

46,5

43

9,62

10,08

10,58

11,05

11,68

12,32

13,05

13,77

14,20

14,77

14,98

80,5

80,5

80

79,5

78,5

77

74,5

71,5

67

61,5

58,5

12,33

12,92

13,56

14,47

15,20

16,10

16,94

17,65

18,25

18,55

7,68

8,06

8,42

8,98

9,42

N 50-250A/A

160 L2

18,5

11,75

B-N 50-250S/A

N 50-250S/A

180 M2

22

88,5

88,5

88

87

86

84

81,5

78,5

75

71

68,5

12,76

13,46

14,15

14,85

15,93

16,84

17,92

19,02

19,91

20,62

20,96

MOTORE
MOTOR

P2
kW

112 M2

POMPA
PUMP

B-N

B-N 65-125E/B

N 65-125E/B

B-N 65-125C/B

N 65-125C/B

132 S2

Q m3/h
Q l/min

24

27

30

33

37,8

42

48

54

60

66

72

84

96

108

120

132

150

450

500

550

630

700

800

900

1000

1100

1200

1400

1600

1800

2000

2200

2500

16,5

16,4

16,2

15,9

15,5

15,1

14,3

13,2

2,86

2,99

3,17

3,34

3,5

3,64

3,81

3,94

4,03

5,5

21,1

21

20,8

20,6

20,3

19,9

19,1

18,2

16,5

14,4

3,68

3,86

4,11

4,35

4,57

4,77

5,02

5,23

5,41

5,5

5,49

25,9

25,8

25,6

25,4

25,1

24,8

24,1

23,3

21,9

20

17,6

4,71

4,92

5,21

5,5

5,77

6,03

6,38

6,69

7,02

7,25

7,36

24,3

24,1

23,9

23,6

23,1

22,3

20,8

18,8

16,3

5,11

5,44

5,75

6,05

6,45

6,8

7,15

7,4

7,52

28,1

28

27,8

27,6

27,1

26,3

24,9

23,1

20,7

5,89

6,26

6,61

6,96

7,44

7,87

8,37

8,74

8,98

32,6

32,5

32,3

32

31,5

30,8

29,5

27,9

25,7

23,0

7,04

7,44

7,84

8,22

8,76

9,25

9,84

10,33

10,7

10,96

36,4

36,3

N 65-125A/B

132 S2

7,5

B-N 65-160D/B

N 65-160D/B

132 S2

7,5

B-N 65-160C/B

N 65-160C/B

160 M2

11

B-N 65-160B/B

N 65-160B/B

160 M2

11

Hm

B-N 65-160AR

N 65-160AR

160 M2

15

P3 kW

B-N 65-200C/A
B-N 65-200B/A

N 65-160A/B
N 65-200C/A
N 65-200B/A

160 M2
160 M2
160 L2

35,9

35,5

34,8

33,7

32,1

30,0

27,5

8,91

9,36

9,99

10,57

11,27

11,85

12,33

12,71

40,2

40

39,5

38,8

37,6

36,1

34,2

31,7

8,91

9,44

9,96

10,47

11,19

11,85

12,64

13,33

13,92

14,42

44

43,5

43

42,5

41

39,5

37,5

35

31

27*

10,4

11

11,6

12,1

12,8

13,2

13,8

14,6

14,8

15,2

18,5

50

49,5

49

48,5

47,5

46,5

44,5

42

39

12,25

12,85

13,45

14

14,75

15,4

16,3

17,1

17,7

18,4

56,5

56

55,5

55

54,5

53,5

51

48,5

45,5

41,5*

20,4

21

15
15

22

180 M2

22

B-N 65-250B/A

N 65-250B/A

200 L2

30

79,5
20,2

200 L2

37

90

89,5

23,6

25

MOTORE
MOTOR

P2
kW

Q m3/h
Q l/min

13,6

14,3

15

15,7

16,65

17,6

18,6

19,5

64

63,5

63

61,5

60

57,5

54,5*

50*

15,3

16,2

17,1

18

19

20

21

22

79

78,5

21,3

22,3

23,3

24,7

26

27,7

29,3

89

88,5

87,5

86

83,5*

78,5*

26,2

27,3

29

30,5

32,5

34

78

77

75

72*

66

75

84

96

108

120

132

150

168

180

192

210

240

270

300

1100

1250

1400

1600

1800

2000

2200

2500

2800

3000

3200

3500

4000

4500

5000

21,5

20,9

17,4

15,9

13,4

10,6

N 80-160E/B

132 S2

7,5

19,9

18,7

6,81

6,92

7,05

7,15

7,22

7,26

7,27

7,21

N 80-160D/B

160 M2

11

25,2

24,5

23,5

22,4

21,1

19,6

17,2

14,4

8,22

8,49

8,73

8,93

9,09

9,23

B-N 80-160C/B

N 80-160C/B

160 M2

11

28,7

28,2

27,4

26,4

25,1

23,8

21,3

18,5

16,4

9,04

9,35

9,74

10,09

10,39

10,65

10,91

10,99

10,93

B-N 80-160B/B

N 80-160B/B

160 M2

15

34,8

34,5

33,8

33

32,1

30,9

28,9

26,4

24,5

22,4

11,37

11,83

12,42

13

13,53

14,01

14,63

15,07

15,26

15,34

B-N 80-160A/B

N 80-160A/B

160 L2

18,5

39,9

39,6

39

38,2

37,4

36,4

34,5

32,2

30,3

28,1

13,25

13,82

14,58

15,3

15,99

16,62

17,45

18,09

18,4

18,59

B-N 80-200B/A

N 80-200B/A

180 M2

22

46,5

46

44,5

43,5

42

35,5*

32*

15,7

16,6

18,6

19,4

20,2

21,3

B-N 80-200A/A

N 80-200A/A

200 L2

30

56

55,5

55

54

53

52

49,5*

46*

43*

20

21,1

22,3

23,5

24,7

25,7

27,2

28,5

29,3

B-N 80-250E/A

N 80-250E/A

180 M2

22

44,5

200 L2

30

B-N 80-250C/A

N 80-250C/A

200 L2

37

B-N 80-250B/A

N 80-250B/A

225 M2

45

B-N 80-250A/A

N 80-250A/A

250 M2

55

B-N 100-200E/A

N 100-200E/A

160 L2

18,5

67*

60

B-N 80-160D/B

N 80-250D/A

35*

1000

B-N 80-160E/B

B-N 80-250D/A

9,06

36,2

180 M2

PUMP
POMPA

17,7

8,45

N 65-250C/A

B-N

11,8

40,4

N 65-200A/A

PUMP
POMPA

9,2

7,98

B-N 65-250C/A

N 65-250A/A

11,4

40,5

B-N 65-200A/A

B-N 65-250A/A

9,23

400

B-N 65-125A/B

B-N 65-160A/B

9,19

11,08

B-N 50-250A/A

POMPA
PUMP

9,15

9,08

9,01

Hm
P3 kW

45,5
17,7

39*

9,23

21,8

22

51

50

48,5

46,5

42

38*

33*

16,2

17,1

18,2

19,1

20

20,6

21,4

21,9

22

65

64

62,5

61

59

56,5

53*

49*

45,5*

21,3

22,3

24

25,3

26,5

27,5

28,6

29,4

29,8

30

73,5

73

72

70,5

69

67

63*

59*

55,5*

51,5*

24,6

26

27,8

29,5

31

32,4

33,8

35,2

35,7

36,2

84

83,5

29*
41*

81,5

80

78

74,5*

70,5*

67*

63*

29

30,7

32,9

35

36,7

38,3

40,1

41,8

43

44,1

95

94,5

93,5

92,5

91,5

90

87,5*

84*

80,5*

76,5*

33,7

35,6

38,1

40,5

42,7

44,8

47,4

50

51,5

30

29,5

29

28

27

26

25

23

19*

14,5

15,1

15,7

16,6

17,2

17,6

17,9

18,3

18,4

36

35,5

35

34

33

32

31

29

82,5

53

24,5*

19*

B-N 100-200D/A

N 100-200D/A

180 M2

22

17,1

17,8

18,5

19,5

20,2

20,7

21,1

21,6

22

22

B-N 100-200C/A

N 100-200C/A

200 L2

30

45

44,5

44

43,5

42,5

41,5

40,5

39

34,5*

29*

22

22,9

23,8

25,1

26,2

26,9

27,5

28,3

29,4

29,8

30

B-N 100-200B/A

N 100-200B/A

200 L2

37

54

53,5

53

52,5

51,5

50,5

49,5

48

44*

38,5*

27,1

28,3

29,4

30,9

32,2

33,3

34

34,9

32

36,3

37

37,2

B-N 100-200A/A

N 100-200A/A

225 M2

45

61,5

61

60

59,5

58,5

58

56,5

53*

48*

42

31

32,4

33,8

35,8

37,7

39

40

41,5

43,5

45

45,5

73

72,5

71,5

70

68,5

67

65

60,5

22

B-N 100-250B/A

N 100-250B/A

250 M2

55

73,5

61*

55,5*

39

40,6

42,1

44,3

46,4

47,8

48,8

50,5

48,5

52,9

54,7

55,8

B-N 100-250A/A

N 100-250A/A

280 S2

75

91

90,5

90

89,5

88,5

88

87

85

81*

75*

67

50

52,5

55

58,5

61,5

63,5

65,5

68

71,5

74,5

75,5

Standard construction.

P2 Rated motor power output.

B-N

Bronze construction.

P3 Pump power input.

H Total head in m.

57

* Maximum suction lift 1-2 m.

Minimum positive suction head 1 m.

N4

End-Suction Centrifugal Pumps


standardized EN 733

Coverage chart n 1450 rpm


10 Imp. g.p.m. 20
10 U.S. g.p.m. 20

30
30

40

40

50

100

50

200

100

200

300
300

400 500

1000

400 500

2000

1000

2000

3000

70
200
50
N4 80-400

N4
100-400

40
30

N4
80-315

N4 65-315

N4
125-400

N4 40-250

N4 50-250

N4 65-250

N4 50-200

N4
65-200

N4
80-250

100

N4 40-200

N4 32-200

10

N4 50-160

N4 40-160

N4 32-160

N4
65-160

N4 50-125

N4 32-125

50
40

N4
125-250

N4
80-200

30

N4
100-200

20

N4
80-160

5
4

N4
150-315

N4
100-250

ft

N4
N4 100-315 125-315

20

H
N4
150-400

N4
65-125
10

2
2
40

10

m 3/h 5
Q l/min
100
50

150

20
200

300

30

40

400 500

50

200

100
1000

2000

300

400 500

700

10000

3000 4000 5000

72.842.C

Tolerances according to UNI EN ISO 9906:2012

Performance n 1450 rpm


POMPA
PUMP

POMPA
PUMP

MOTORE
MOTOR

P2
kW

B-N4 32-125F/A

N4 32-125F/A

71 M4

0,25

B-N4 32-125D/A

N4 32-125D/A

71 M4

0,25

B-N4 32-125A/A

N4 32-125A/A

71 M4

0,25

B-N4 32-160B/A

N4 32-160B/A

71 M4

0,37

B-N4 32-160A/A

N4 32-160A/A

71 M4

0,37

B-N4 32-200B/A

N4 32-200B/A

80 M4

0,55

B-N4 32-200A/A

PUMP
POMPA
B-N4 40-160C/A
B-N4 40-160B/A

N4 32-200A/A

PUMP
POMPA
N4 40-160C/A
N4 40-160B/A

80 M4

0,75

MOTOR
MOTORE

P2
kW

71 M4

0,37

80 M4

N4 40-160A/A

80 M4

0,75

B-N4 40-200B/A

N4 40-200B/A

90 S4

1,1

B-N4 40-200A/A

N4 40-200A/A

90 S4

1,1

B-N4 40-250C/A

N4 40-250C/A

90 L4

1,5

B-N4 40-250A/A

N4

N4 40-250B/A
N4 40-250A/A

Standard construction.

B-N4 Bronze construction.

100 LA4
100 LB4

2,4

3,6

4,2

4,8

5,4

6,6

7,5

8,4

9,6

10,8

12

13,2

40

50

60

70

80

90

100

110

125

140

160

180

200

220

3,6

3,6

3,5

3,5

3,4

3,2

2,8

2,4

1,9

1,1

0,08

0,09

0,095

0,105

0,11

0,115

0,07

Hm
P3 kW

Q m3/h
Q l/min

Hm
P3 kW

2,2
3

0,075

0,1

0,1

0,115

4,7

4,7

4,7

4,7

4,6

4,6

4,5

4,3

4,1

3,8

3,3

2,6

0,095

0,075

0,11

0,115

0,125

0,13

0,135

0,145

0,15

0,155

0,165

0,17

5,7

5,8

5,8

5,7

5,7

5,7

5,6

5,5

5,4

5,2

4,8

4,3

0,12

0,1

0,135

0,145

0,15

0,16

0,165

0,175

0,185

0,195

0,205

0,215

7,6

7,5

7,4

7,3

7,2

7,1

6,9

6,7

6,3

5,9

5,2

4,2

0,13

0,125

0,15

0,16

0,17

0,18

0,19

0,2

0,21

0,215

0,23

0,235

8,95

8,9

8,8

8,7

8,6

8,5

8,3

7,9

7,5

6,8

5,1

0,17

0,18

0,19

0,2

0,21

0,22

0,23

0,24

0,26

0,275

0,29

0,305

0,315

12,5

0,55

B-N4 40-160A/A

B-N4 40-250B/A

Q m3/h
Q l/min

12,4

10,6

12,3

12,2

12

11,8

11,6

10

8,9

6,2

4,7

0,28

0,3

0,315

0,33

0,345

0,36

0,375

0,39

0,41

0,43

0,455

0,48

0,5

0,515

14,3

14,2

14,1

14

13,9

13,7

13,5

13,3

12,9

12,3

11,3

10,2

8,9

7,5

0,35

0,375

0,4

0,42

0,44

0,46

0,48

0,5

0,525

0,55

0,585

0,61

0,635

0,655

11,2

7,6

5,4

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8

18,9

21

24

27

30

90

100

110

125

140

160

180

200

220

250

280

315

350

400

450

500

6,1

5,9

5,9

5,8

5,6

5,4

5,2

4,5

3,9

3,1

2,3

0,17

0,18

0,19

0,2

0,21

0,23

0,24

0,25

0,26

0,27

0,28

0,29

0,3

7,6

7,6

7,6

7,6

7,6

7,3

7,1

6,9

6,6

6,3

5,7

2,7

0,22

0,23

0,24

0,26

0,27

0,29

0,31

0,32

0,34

0,36

0,38

0,39

0,4

0,41

9,6

9,6

9,6

9,6

9,4

9,3

9,1

8,8

8,4

7,9

7,2

6,4

5,1

3,5

0,28

0,3

0,31

0,33

0,35

0,37

0,4

0,42

0,44

0,47

0,49

0,51

0,53

0,55

0,56

13

12,9

12,8

12,7

12,6

12,4

11,5

12,2

12

10,8

10

0,51

0,53

0,53

0,54

0,57

0,60

0,63

0,66

0,68

0,71

0,75

0,78

0,81

14,8

14,7

14,6

14,5

14,4

14,2

14,2

14

13,8

13,6

13

12,2

8,6

11,3

7
10

0,59

0,6

0,6

0,61

0,64

0,67

0,71

0,74

0,77

0,8

0,85

0,9

0,94

0,97

0,83

17,4

17,3

17,2

17,2

17

16,8

16,6

16,3

16

15,1

13,8

12,1

10,4

7,2

2,8

0,689

0,715

0,74

0,779

0,817

0,865

0,912

0,967

1,018

1,092

1,134

1,178

1,248

1,301

1,348

21,4

21,5

21,4

21,3

21,2

21

20,9

20,8

20,5

20

19,5

18,3

16,4

13,3

10

0,908

0,942

0,99

1,025

1,075

1,140

1,203

1,266

1,327

1,405

1,482

1,567

1,645

1,752

1,815

1,887

22,9

22,8

22,9

22,9

22,8

22,5

22,5

22,2

22

21,8

21,4

20,4

18,9

16

12,6

1,068

1,104

1,15

1,193

1,246

1,316

1,385

1,454

1,521

1,638

1,733

1,817

1,933

2,068

2,168

2,267

P2 Rated motor power output.

H Total head in m.

P3 Pump power input.

58

* Maximum suction lift 1-2 m.

N4

End-Suction Centrifugal Pumps


standardized EN 733

Performance n 1450 rpm


POMPA
PUMP

POMPA
PUMP

B-N4

N4

B-N4 50-125F/A

N4 50-125F/A

MOTORE
MOTOR
71 M4

P2
kW

Q m3/h
Q l/min

0,37

10,8

12

13,2

15

16,8

18,9

21

24

27

30

33

37,8

42

48

180

200

220

250

280

315

350

400

450

500

550

630

700

800

0,5

4,5

4,5

4,4

4,3

4,1

3,8

3,5

2,9

2,2

1,4

0,26

0,275

0,285

0,3

0,31

0,32

0,325

0,33

0,325

0,315

5,5

5,5

5,4

5,4

5,2

5,1

4,8

4,4

3,8

3,2

2,5

0,32

0,335

0,345

0,365

0,385

0,4

0,415

0,425

0,435

0,43

0,425

6,4

6,4

6,3

6,3

6,2

6,1

5,9

5,6

5,2

4,6

2,9

0,37

0,39

0,405

0,425

0,45

0,51

0,525

0,535

0,535

0,525

0,3

B-N4 50-125D/A

N4 50-125D/A

80 M4

0,55

B-N4 50-125A/A

N4 50-125A/A

80 M4

0,75

B-N4 50-125S/A

N4 50-125S/A

80 M4

0,75

6,8

6,8

6,8

6,8

6,7

6,6

6,4

6,2

5,8

5,3

4,8

3,8

0,4

0,42

0,435

0,46

0,48

0,505

0,525

0,555

0,57

0,585

0,59

0,59

1,1

8,2

8,2

8,2

8,1

7,8

7,6

7,2

6,7

6,2

5,5

4,4

3,3

0,449

0,469

0,496

0,524

0,555

0,584

0,610

0,643

0,671

0,683

0,692

0,687

0,673

9,6

9,6

9,6

9,5

9,5

9,3

9,1

8,8

8,3

7,8

7,2

6,1

4,9

3,1

0,578

0,600

0,632

0,670

0,705

0,742

0,778

0,811

0,833

0,850

0,862

0,861

0,844

B-N4 50-160B/A

N4 50-160B/A

90 S4

0,47

0,49

B-N4 50-160A/A

N4 50-160A/A

90 S4

1,1

Hm

0,555

B-N4 50-200C/A

N4 50-200C/A

90 S4

1,1

11,8

11,8

11,7

11,7

11,5

11,3

10,9

10,4

9,8

8,1

6,3

4,7

P3 kW

0,617

0,647

0,682

0,720

0,759

0,801

0,841

0,888

0,927

0,957

0,979

1,005

1,010

13,4

13,4

13,4

13,3

13,1

12,9

12,6

12,1

11,5

10,8

9,9

8,2

6,4

3,7

0,772

0,807

0,840

0,889

0,949

0,998

1,051

1,115

1,171

1,213

1,251

1,278

1,299

1,301

14,9

14,9

14,9

14,9

14,8

14,6

14,4

14

13,4

12,8

12

10,4

8,6

0,923

0,962

1,019

1,074

1,135

1,194

1,273

1,345

1,409

1,464

1,535

1,576

1,596

B-N4 50-200B/A

N4 50-200B/A

90 L4

1,5

B-N4 50-200A/A

N4 50-200A/A

100 L4

2,2

0,883

B-N4 50-250D/A

N4 50-250D/A

100 L4

2,2

14,5

14,4

14,3

14

13,7

13,4

13

12,2

11,2

9,7

8,1

5,4

2,3

0,843

0,886

0,929

0,990

1,049

1,098

1,160

1,230

1,300

1,364

1,395

1,435

1,468

100 L4

2,2

17,8

17,8

17,7

17,5

17,2

16,8

16,4

15,7

14,9

13,8

12,4

9,7

6,8

1,091

1,140

1,188

1,258

1,324

1,397

1,465

1,554

1,633

1,700

1,755

1,818

1,844

20,7

20,7

20,7

20,6

20,4

20

19,5

18,9

18,2

17,1

15,9

13,2

10,6

5,8

1,374

1,437

1,499

1,591

1,680

1,781

1,878

2,009

2,130

2,241

2,320

2,448

2,510

2,580

22,7

22,7

22,6

22,5

22,4

22,1

21,6

21

20,2

19,4

18,3

16,4

13,6

1,493

1,561

1,628

1,728

1,825

1,935

2,042

2,186

2,322

2,445

2,557

2,706

2,804

2,893

B-N4 50-250C/A
B-N4 50-250B/A
B-N4 50-250A/A

N4 50-250C/A
N4 50-250B/A
N4 50-250A/A

POMPA
PUMP

POMPA
PUMP

B-N4

N4

B-N4 65-125E/B
B-N4 65-125C/B

N4 65-125E/B
N4 65-125C/B

100 L4

112 M4

MOTORE
MOTOR

P2
kW

80 M4

0,75

80 M4

Q m3/h
Q l/min

0,75

21

24

27

30

33

37,8

42

48

54

60

66

75

84

96

108

120

350

400

450

500

550

630

700

800

900

1000

1100

1250

1400

1600

1800

2000

4,1

2,9

2,3

4,1

3,9

3,8

3,6

3,3

0,38

0,4

0,41

0,44

0,45

0,48

0,49

0,5

5,3

5,2

5,2

5,1

4,8

4,6

4,1

3,6

0,49

0,51

0,54

0,58

0,6

0,63

0,65

0,69

0,69

0,69

6,5

6,4

6,4

6,3

6,2

5,8

5,5

4,4

0,5

B-N4 65-125A/B

N4 65-125A/B

90 S4

1,1

0,61

B-N4 65-160C/B

N4 65-160C/B

90 S4

1,1

6,1

6,1

5,9

5,8

5,6

5,3

4,8

4,2

0,57

0,61

0,65

0,69

0,72

0,78

0,83

0,88

0,92

0,93

B-N4 65-160B/B

N4 65-160B/B

90 S4

1,1

7,2

7,1

7,1

6,8

6,6

6,3

5,8

5,2

4,5

0,68

0,73

0,77

0,82

0,86

0,92

0,97

1,03

1,07

1,11

1,12

8,8

8,8

8,7

8,7

8,6

8,5

8,3

7,6

7,1

B-N4 65-160A/B
B-N4 65-160S
B-N4 65-200B/A

N4 65-160A/B
N4 65-160S
N4 65-200B/A

90 L4
100 L4
100 L4

1,5
2,2
2,2

B-N4 65-200A/A

N4 65-200A/A

100 L4

B-N4 65-250B/A

N4 65-250B/A

112 M4

B-N4 65-250A/A
B-N4 65-315C/A

N4 65-250A/A
N4 65-315C/A

132 S4
132 S4

5,2

0,93

0,98

1,04

1,09

1,17

1,24

1,32

1,39

1,44

1,48

1,51

10,2

10,1

10,1

10

9,9

9,7

9,4

9,1

8,6

5,7

1,09

1,15

1,22

1,28

1,34

1,44

1,52

1,62

1,71

1,79

1,86

1,93

1,96

11,9

11,8

11,7

11,6

11,1

10,8

10,2

6,2

4,3

9,5

8,7

1,25

1,33

1,4

1,47

1,53

1,62

1,69

1,78

1,86

1,93

1,98

14,1

14

13,9

13,8

13,7

13,4

13,1

12,6

11,9

11,1

10,2

8,8

7,2

1,57

1,66

1,75

1,84

1,91

2,02

2,13

2,24

2,35

2,46

2,56

2,65

2,7

18

11,4

7,8

17,3

16,9

16,3

15,4

14,4

13,1

10,8

8,5

2,5

2,66

2,8

3,18

3,36

3,5

3,68

3,82

5,5

21,9

21,7

21,6

21,5

20,8

19,5

18,5

17,5

15,4

12,8

2,88

20,2

2,74

3,02

3,16

3,3

3,52

3,72

3,97

4,22

4,43

4,63

4,91

5,5

25,8

25,7

25,5

25,3

25

24,4

23,8

22,8

21,5

20

18,2

15

11

3,12

3,31

3,49

3,67

3,83

4,05

4,25

4,5

4,75

4,96

5,12

5,3

5,44

31

31

30,9

30,8

30,6

30,2

29,7

28,8

27,8

26,5

25

22,2

18,6

P2
kW

Q m3/h
Q l/min

1,1

B-N4 80-160B/B

N4 80-160B/B

90 L4

1,5

B-N4 80-160A/B

N4 80-160A/B

100 L4

2,2

B-N4 80-200C/A

N4 80-200C/A

100 L4

2,2

B-N4 80-200B/A

N4 80-200B/A

100 L4

B-N4 80-200A/A

N4 80-200A/A

112 M4

B-N4 80-250C/A

N4 80-250C/A

112 M4

132 S4

6,4

0,87

10,2

17,6

MOTOR
MOTORE

N4 80-250B/A

0,93

2,38

11

B-N4 80-250B/A

0,91

17,7

7,5

90 S4

0,91

2,26

132 M4

N4 80-160C/B

0,84

17,8

160 M4

B-N4 80-160C/B

0,8

2,14

N4 65-315A/A

N4

0,75

21,8

N4 65-315B/A

POMPA
PUMP

0,73

17,9

B-N4 65-315A/A

B-N4

P3 kW

0,69

2,02

B-N4 65-315B/A

POMPA
PUMP

Hm

0,65

5,5

21,2

5,15

3,97

4,23

4,45

4,65

4,85

5,15

5,4

5,75

6,1

6,4

6,65

35,9

35,9

35,8

35,7

35,5

35,1

34,6

33,8

32,8

31,6

30,2

27,8

25

4,8

5,1

5,4

5,6

5,8

6,15

6,5

6,9

7,3

7,6

7,9

8,3

8,7

30

33

37,8

42

48

54

60

66

75

84

96

108

120

132

150

168

500

550

630

700

800

900

1000

1100

1250

1400

1600

1800

2000

2200

2500

2800

6,1

6,1

5,9

5,8

5,5

5,2

4,9

4,6

3,3

0,87

0,88

0,9

0,92

0,95

0,98

1,02

1,03

1,04

7,8

7,7

7,6

7,5

7,3

6,8

6,4

5,9

5,2

4,1

1,14

1,16

1,2

1,23

1,27

1,31

1,34

1,37

1,41

1,44

1,46

9,9

9,8

9,7

9,5

9,3

8,5

5,9

1,49

1,53

1,6

1,66

1,74

1,82

1,9

1,97

2,07

2,15

2,22

2,24

10,3

10,2

10,1

10

9,8

9,5

9,1

8,6

7,7

6,6

4,6

10

10

7,2

1,62

1,7

1,77

1,86

1,93

2,18

2,2

12,1

12

11,9

11,8

11,7

11,4

11,1

10,6

9,8

7,5

1,8

1,88

2,1

2,22

2,33

2,43

2,52

2,62

2,68

2,72

2,72

13,9

13,8

13,7

13,6

13,5

13,3

13

12,6

11,8

11

9,6

7,9

2,22

2,35

2,48

2,65

2,8

2,94

3,05

3,2

2,13

3,35

3,44

3,46

3,44

16,9

16,8

16,7

16,6

15,4

14,8

1,56

2,06

2,13

5,7

16,3

15,9

13,9

12,7

Hm

2,37

2,5

2,65

2,8

3,2

3,35

3,49

3,68

3,83

3,97

3,98

3,88

20,7

20,6

20,5

20,4

20,3

20

19,6

19,1

18,2

17,1

15,4

13,5

11,4

P3 kW

3,25

3,38

3,58

3,75

4,23

4,42

4,6

4,87

5,13

5,35

5,49

5,55

5,45

23,7

23,7

23,6

23,5

23,3

23

22,7

22,2

21,5

20,5

19

17,2

15,1

12,7*

11,1

9,3

7,2
9*

B-N4 80-250A/A

N4 80-250A/A

132 M4

7,5

3,94

4,1

4,33

4,54

4,83

5,08

5,33

5,58

5,91

6,23

6,54

6,82

6,98

7,05

B-N4 80-315C/B

N4 80-315C/B

160 M4

11

25,7

25,8

25,8

25,8

25,8

25,6

25,4

25

24,4

23,6

22,2

20,4

18,3

15,9

4,6

4,8

5,1

5,4

5,7

6,1

6,4

6,7

7,2

7,6

8,1

8,5

8,9

B-N4 80-315B/B

N4 80-315B/B

160 M4

11

30,3

30,5

30,6

30,7

30,7

30,7

30,5

30,2

29,6

28,8

27,5

25,9

24,1

22

5,3

5,5

5,9

6,2

6,6

7,5

7,9

8,5

9,7

10,2

10,8

11,2

B-N4 80-315A/B

N4 80-315A/B

160 L4

15

36,3

36,4

36,5

36,6

36,6

36,5

36,4

36,1

35,6

35

33,9

32,5

30,9

29

6,7

6,9

7,3

7,7

8,2

8,7

9,2

9,7

10,4

11,1

12

12,7

13,4

14

14,8

B-N4 80-315S

N4 80-315S

180 M4

18,5

39,1

39,2

39,3

39,4

39,5

39,4

39,3

39,2

38,7

38,1

37,1

35,7

34,1

32,1

28,3

22,5*

7,6

7,8

8,3

8,7

9,2

9,8

10,3

10,8

11,6

12,4

13,4

14,3

15,1

15,8

16,8

17,7

46,5

46,3

46,1

45,8

45,2

44,5

43,5

42,4

40

37,2

32,5

26,2

18,5

9,75

10,25

10,85

11,25

11,9

12,55

13,2

13,85

14,8

15,5

16,5

17,5

18

54

53,8

53,6

53,3

53

52,4

51,6

50,6

48,7

46,1

36,5

29,5

11,5

11,9

12,5

13,1

13,95

14,7

15,45

16,15

17,35

18,4

19,5

20,6

21,55

22,3

54

50,5

45,5

40

32,5*

20,55

22,1

23,5

24,9

26

B-N4 80-400C/A

N4 80-400C/A

180 M4

18,5

B-N4 80-400B/A

N4 80-400B/A

180 L4

22

B-N4 80-400A/A

N4

N4 80-400A/A

Standard construction.

B-N4 Bronze construction.

200 L4

30

61,5

61,4

61,3

61,1

60,8

60,2

59,4

58,4

56,5

12,65

13,2

14

14,7

15,6

16,5

17,4

18,25

19,4

P2 Rated motor power output.

H Total head in m.

P3 Pump power input.

59

* Maximum suction lift 1-2 m.

42

9,2

21*

25,3

N4

End-Suction Centrifugal Pumps


standardized EN 733

Performance n 1450 rpm


PUMP
POMPA

PUMP
POMPA

B-N4

N4

MOTOR
MOTORE

P2
kW

B-N4 100-200C/A

N4 100-200C/A

100 L4

B-N4 100-200B/A

N4 100-200B/A

112 M4

B-N4 100-200A/A

N4 100-200A/A

132 S4

Q m3/h
Q l/min

5,5

B-N4 100-250B/A

N4 100-250B/A

132 M4

7,5

B-N4 100-250A/A

N4 100-250A/A

160 M4

11

B-N4 100-315C/A

N4 100-315C/A

160 M4

11

B-N4 100-315B/A

N4 100-315B/A

160 L4

15

Hm

48

54

60

66

75

84

96

108

120

132

150

168

180

192

210

800

900

1000

1100

1250

1400

1600

1800

2000

2200

2500

2800

3000

3200

3500

9,4

9,3

9,2

9,1

8,9

8,5

7,3

6,5

5,6

2,1

2,2

2,3

2,4

2,5

2,6

2,7

2,8

2,85

2,9

2,85

12

11,9

11,5

11,2

10,7

11,8

11,7

2,65

2,8

2,95

3,1

3,3

3,45

3,65

3,85

3,95

3,95

15,2

15,2

15,1

15

14,9

14,7

14,3

13,8

13,1

12,2

10,7

7,5*

6*

3,65

3,85

4,15

4,4

4,6

4,85

5,1

5,3

5,45

5,55

5,65

5,65

5,55

19,5

19,5

19,4

19,3

19

18,7

18,2

17,5

16,6

15,6

13,8

11,7

10

8,4

5,5

4,8

5,2

5,4

5,75

6,05

6,4

6,7

7,3

7,5

7,5

7,45

7,35

7,15

22,3

22,1

21,9

19,8

18,8

17,1

15

13,4

10

8,4

6,7

4,5
3,8

22,3

22,2

21,7

21,2

11,7

8,9

5,5

5,8

6,05

6,25

6,6

6,95

7,35

7,75

8,1

8,35

8,7

9,05

8,9

26,9

26,9

26,8

26,6

26,2

25,7

24,9

23,8

22,7

21,3

18,9

15,9

11,3*

6,6

7,35

7,65

8,1

8,5

9,5

9,85

13,7

10,2

10,7

10,9

11

11

31,5

31,5

31,4

31,3

31,2

30,8

30,2

29,3

28,2

26,9

24,6

21,8

19,8

17,6*

7,8

8,25

8,65

9,6

10,2

10,9

11,5

12,1

12,6

13,3

13,9

14,1

14,4

14,4

36,9

36,9

36,8

36,7

36,6

36,4

36

35,3

34,5

33,4

31,4

29

27,2

25,3*

22,2*

9,7

10,2

10,7

11,2

11,9

12,5

13,3

14,1

14,9

15,6

16,6

17,4

17,9

18,3

18,75

41,3

41,2

41,1

41

40,7

40,4

39,8

39

38

36,5

34

31

28,7

26

11,1

11,8

12,5

13,2

14

14,8

16

17

18

18,9

20

21

21,7

P3 kW

20,5

9,3

14*

B-N4 100-315A/A

N4 100-315A/A

180 M4

18,5

B-N4 100-400C/A

N4 100-400C/A

180 L4

22

B-N4 100-400B/A

N4 100-400B/A

200 L4

30

50,2

50,1

50

49,9

49,7

49,4

48,8

48

47,1

46

44

41,3

39,5

37

15,2

16

16,8

17,4

18,4

19,3

20,6

21,8

23

24,2

25,7

27

27,8

28,5

225 S4

37

58,2

58,1

58

57,9

57,8

57,6

57,2

56,3

55,7

54,5

52,7

50,5

49

47

44*

17,8

18,75

19,7

20,5

21,7

22,9

24,4

25,9

27,4

28,8

30,9

32,7

33,85

35

36,5

MOTOR
MOTORE

P2
kW

B-N4 100-400A/A

N4 100-400A/A

PUMP
POMPA

PUMP
POMPA

B-N4

N4

B-N4 125-250E/A
B-N4 125-250D/A
B-N4 125-250C/A
B-N4 125-250B/A
B-N4 125-250A/A
B-N4 125-315C/A

N4 125-250E/A
N4 125-250D/A
N4 125-250C/A
N4 125-250B/A
N4 125-250A/A
N4 125-315C/A

132 S4
132 M4
160 M4
160 M4
160 L4
180 M4

Q m3/h
Q l/min

84

96

108

120

132

150

168

180

192

210

240

270

300

330

1400

1600

1800

2000

2200

2500

2800

3000

3200

3500

4000

4500

5000

5500

10,1

9,7

8,3

7,8

6,2

4,4

4,2

4,5

4,75

4,95

5,05

5,2

5,35

5,45

5,5

5,5

5,35

14

13,9

13,7

13,4

13

12,4

11,6

11

10,4

9,4

7,4

11

5,5
7,5
11

15
18,5

B-N4 125-315B/A

N4 125-315B/A

180 L4

22

B-N4 125-315A/A

N4 125-315A/A

200 L4

30

Hm
P3 kW

10,8

10,5

9,1

7,2

5,7

5,95

6,2

6,45

6,75

7,1

7,2

7,35

7,4

7,1

16,6

16,4

16,2

15,9

15,4

14,6

14,1

13,5

12,5

10,4

8,2

5,8

6,3

6,7

7,1

7,4

7,65

8,05

8,4

8,6

8,75

9,2

9,2

9,05

17

16,3

15,3

13,3

10,9

8,2

11,45

19,2

19,1

18,9

18,7

18,2

17,5

7,8

8,25

8,7

9,1

9,45

10

10,35

10,6

10,85

11,1

11,4

22,7

22,7

22,6

22,4

22,2

21,8

21,2

20,8

20,1

19,33

17,4

15

12,4

9,2

9,75

10,3

10,85

11,3

12

12,6

12,95

13,25

13,75

14,3

14,5

14,55

14,4

27,9

27,8

27,7

27,6

27,2

26,5

25,6

24,9

24

22,8

20,2

17

13,5

9,5*

9,3

11,5

12,15

12,8

13,4

14

14,7

15,4

15,8

16,2

16,7

17,3

17,7

18

18

31,8

31,7

31,6

31,5

31,1

30,6

29,7

29,1

28,5

27,3

24,9

22

18,5

14,3*

12,75

13,6

14,45

15,3

15,9

16,8

17,7

18,4

19

19,7

20,6

21,4

22

22,1

36,8

36,8

36,7

36,6

36,4

25,3

21,6*

35,9

35,2

34,7

34,2

33,2

31

28,4

15,5

16,5

17,5

18,3

19,1

20,4

21,6

22,4

23,1

24,15

25,6

26,6

27,6

28,45

45,4

45,3

45,2

45,1

44,9

44,4

43,7

43

42

40

37

33

28,5*

23,5*

N4 125-400C/A

225 S4

37

19,4

20,7

22

23,3

24,6

26,5

28,2

29,3

30,2

31,4

33,4

35

35,9

36,75

B-N4 125-400B/A

N4 125-400B/A

225 M4

45

51,4

51,3

51,2

51,1

50,9

50,4

49,7

49

48,2

46,8

44

40,5

36*

31,5*

22,9

24,3

25,7

27,1

28,4

30,35

32,2

33,3

34,4

36

38,5

41

43

44,5

B-N4 125-400A/A

N4 125-400A/A

250 M4

55

59,2

59,1

59

58,9

58,7

58,2

57,7

57,2

56,7

55,7

53,5

50,5

46,5*

42,5*

27,8

29,4

30,9

32,4

33,9

36,2

38,4

39,8

41,2

43,2

46,2

49,2

52,1

54,4

PUMP
POMPA

PUMP
POMPA

B-N4

N4

MOTOR
MOTORE

P2
kW

180 M4

18,5

B-N4 150-315D/A
B-N4 150-315C/A

N4 150-315D/A
N4 150-315C/A

180 L4

B-N4 150-315B/A

N4 150-315B/A

200 L4

30

B-N4 150-315A/A

N4 150-315A/A

225 S4

37

B-N4 150-400C/A

N4 150-400C/A

225 M4

45

B-N4 150-400B/A

N4 150-400B/A

250 M4

55

B-N4 150-400A/A

N4 150-400A/A

280 S4

75

N4

Standard construction.

B-N4 Bronze construction.

132

150

168

180

192

210

240

270

300

330

360

390

420

450

480

2200

2500

2800

3000

3200

3500

4000

4500

5000

5500

6000

6500

7000

7500

8000

21,1

22

21,7

20

18,6

17

15,1

13

10,6

8*

13,8

14,5

15

15,4

15,75

16,2

16,9

17,6

18

18,35

18,45

18,4

18,15

25,6

25,4

25,1

24,9

24,7

24,2

23,3

22

20,4

18,5

16,5

14,1

11,6*

15,6

16,44

17,2

17,65

18,1

18,8

19,7

20,6

21,3

21,75

22

22

22

21,65

30,6

30,6

30,5

30,3

30,1

29,7

29

27,9

26,5

24,9

23

20,8

18,3*

15,4*

22,8

22

Hm
P3 kW

29,4

11,3

B-N4 125-400C/A

Q m3/h
Q l/min

33,5*

5,1

5,4

16,7
19,3

11

22

22,6

22,3

8,9*

19

20

21

21,6

22,15

23

24,35

25,7

26,6

27,5

28,1

28,7

28,9

29

35,6

35,6

35,5

35,4

35,3

35,2

34,6

33,7

32,5

31

29,2

27,1

24,7*

21,8*

23,1

24,4

25,7

26,5

27,2

28,3

30

31,6

33,1

34,3

35,4

36,3

37

37,5

37,8

45

44,9

44,7

44,5

44

43,5

42,5

40,5

38,5

36

33,5

30,5

27*

23,5*

19,5*

27,9

29,65

31,4

32,6

33,8

35,3

37,7

39,7

41,3

42,7

43,8

44,1

44,1

44

43

50,8

50,7

50,5

50,3

50

49,5

48,5

47

45

43

40,5

38

35*

32*

28,5*

47,7

18,5*

31,4

33,6

35,8

36,9

38,2

40

42,8

45,5

49,8

51,5

53

54,1

54,6

54,8

58,8

58,7

58,6

58,5

58,3

57,9

57

55,5

54

52

49,5

47

44*

41*

37,5*

38,2

40,7

42,8

44,35

45,7

48

51,5

54,4

57,1

59,7

62

64,2

66

67,5

68,4

P2 Rated motor power output.

H Total head in m.

P3 Pump power input.

60

* Maximum suction lift 1-2 m.

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 2900 rpm


0 U.S. g.p.m.20
S 130

40

60

80

A 130

100

70

72%

20

0 U.S. g.p.m.

20

30

40

A 164

NN 32/125
32/125

50

35

50

60

70
120

NN32/160
32/160

55

57 59

70

70

61
63%

68

D 118

60

66

F 103

Hm

50

15

100

B 150

30

65

H ft

Hm

38

80

60 65
66 68

H ft

25

25

80

40
10

20

30

60
20

0
2.4

S 2.0

1.2

P kW

1.2
0.8

0.4

300

10

0.4

NPSH m

20

25

20
15

10

2
0

Q m3/h

0 U.S. g.p.m.

10

20

15

30

A 204

40
40

50
45

72.010

20

47

60

49

25

70

25
25

N
N 32/200
32/200
180

51
52

Q m3/h

00 U.S.
U.S. g.p.m.
g.p.m.

10

5040

60 100 80

100
150

160

120

A 134

62 66

68

40/125
NM
40/12
NN40/125
70%

C 123

15

HHmm

H ft
140

60
50

68

F 115

66
62

F 112

40
50
30
40
20

105

120

30
10

0
20
30
m 3/h 10
5 0 Q l/min
200
400
3
5
10
15
20
2,5 0
m
/h
Q
200
300
l/min 100
20

100

Q m /h

l/s

10

15

100

l/min
1

200
2

300

P kW

0
0

(%)

0
4
5

NPSH
NPSHmm

15

Q m3/h

10

15

72.012

NPSH ft

30
A
500
C
8

C
A
F

61

1
3.0

2.5
0
2.0
1.5

1.0
0.5
0

43
3
2
2
11
00

40
0.5
20
0

1
2.5
0,5
2.0
0
80
1.5

10

l/s 1

600
25
400

60
1.0

P HP

1,5 0

0
50 20
800
35
3

40

P kW

P kW

70
70
60

D 178

40

NPSH m

140
200
80

A 134

15
10

72.011

15

C 122

C 187

Hm

20
20

53%

50

30

1.0

NPSH ft

NPSH m

l/s

15
200

B 3~
B 1~ 2

60

10
100

0.4

l/min

2.0

1.6

0.8

Q m /h

0
0

P HP

300

NPSH ft

200

15

25
400

H ftH ft

20

P HP

15

100

l/min

l/s

10

P HP

10
10

m 3/h
00 Q Q
m3/h 5

10

10

2015

2030

25

40 30

72.014

50
35

00

NPSHftft
NPSH

0
1.6

Q m /h

P kW

0
0

P HP

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 2900 rpm

B 151

25

C 137

20
15
10
5

m3/h 10
200
l/min

20

30
400

40

50
800

600

B
C

2
1
0
80

D 180
100

30
20
10
0

0
0

10

m3/h 10
200
l/min

20

30

40

400

600

12
10
8
6
4
2
0

B
D

50
800

AR

0
80
AR

60

(%)

40

20
0
8

NPSH ft

10
2
0
0

Q m3/h

0 U.S. g.p.m.

10

20

50

30

100

40

50

150

NPSH m

A 251

10

20

100

30

150

200

40

250

50

300

350

30
S 151

300

NM
40/25
N 40/250

90

N 50/125
NM
50/12

A 146

80

250

B 227

60

200

40

40
10

100

30

50

Hm

150

F 124
H ft

50

70

D 136

20

C 215

60

Q m3/h

0 U.S. g.p.m.

200

80
70

10
2

100
90

20

30
20

20

50

10

10

m3/h
l/min

10
200

20

40

30
400

600

20
16
12
8
4
0

12

P kW

50
800
B
C

8
4
0

60

20

30

40

50

500

60

70

80

90

1000

1500
S
D

2
0

(%)

80
60
D

40

20

0
6
4

10
2

Q m3/h

10

20

30

40

50

NPSH m

0
8

NPSH ft

NPSH m

m3/h

Q l/min

20

A
B
C

40

(%)

P kW

16

0
0

P HP

NPSH ft

(%)

C 185
40

0
6

NPSH m

200

NM
40/20
N 40/200

AR 200

B 195

20

Hm

200

50

40

A 204

60

60

150

H ft

P kW

6
5
4
3
2
1
0

100

P HP

0
0

50

20

10
2
0

62

Q m3/h

20

30

40

50

60

70

80

90

NPSH ft

0 U.S. g.p.m.

70

H ft

30

130
120
110
100
90
80
70
60
50
40
30
20
10
0

P HP

NM
40/16
N 40/160

35

Hm

200

Hm

150

P kW

100

A 167

H ft

50

P HP

0 U.S. g.p.m.

40

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 2900 rpm


200

250

300

0 U.S. g.p.m.

350

A 174

N 50/160
NM
50/16
B 162

10

0
0

m3/h

Q l/min

20

30

40

60

50

500

70

80

1000

10
8
6
4
2
0

4
2
0

80

S 209
A 200

50

B 188

Hm

(%)
NPSH m

10

NPSH ft

0 U.S. g.p.m.

20

30

100

60

50

150

200

80

300

90

300
250

60

200

C 209

50
150
40
100

30
20

50
0
0

m3/h
Q l/min

20

30

40

50

500

60

70

80

1000

P kW

20
10

S
A

30

B
C

20
10
0

0
80

A/S
B
C

40
20
0
10

30

20

6
4

10

2
0

Q m 3/h

NPSH ft

(%)

60

NPSH m

P HP

10

0
20

30

40

50

60

70

50

500

60

70

80

1000

90
1500
20

S
A
B

15
10
5

S
A
B

40

20

6
4

10

B 229

70

40

350

N 50/250
50/250
N

A 245

80

70

250

S 255

90

Hm

40

H ft

100

Q m3/h

30

20

5
3
80

0
8

m3/h

Q l/min

10

20

20

0
0

60

200

100

15

0
B

N 50/200
NM
50/20

30

20

NPSH m

(%)

60

50

40

350

10

A
B

60

300

20

1500
A

P kW

90

250

P kW

200

40

P HP

Hm

20

150

150

H ft

30

100

70

130
120
110
100
90
80
70
60
50
40
30
20
10
0

H ft

150

80

63

P HP

100

Q m3/h

20

30

40

50

60

70

80

90

NPSH ft

0 U.S. g.p.m.
40

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 2900 rpm


0 U.S. g.p.m. 100

200

300

400

0 U.S. g.p.m. 100

500

30
A 146

N
65/125
NM
65/12

30

60

600

NM
65/16
N 65/160

130
120
110
100
90

H ft

50

Hm

500

C 150

40

Hm

E 123

400

B 160

70

20

300

AR 167

80

C 134

200

A 175

40

90

D 143

80
70

30

20

60

20

50

60

70

80

1000

90

100 110 120

1500

2000
A

P HP

2
0

(%)
10

0 U.S. g.p.m.

60

50

200

70

80

300

A 208

60

64

90

400

68

70

10
0

Q m3 /h 20 30 40 50 60 70 80 90 100 110 120 130 140

0 U.S. g.p.m. 100

200

A 252

90

180

300
56

60

400

N 65/250
NM(S)
65/250

H ft
120

66

B 240

80

140

40

68%

100

240
70
220
200

60

l/s 4

12

60
1000
16

80

100
1500

20

24

28

120
2000
32

P kW

36

20
15
10

Q m3/h 20

40

60

80

100

120

NPSH m

12

16

80

100
1500

20

24

28

40

30

20

20
10

NPSH ft

NPSH m

72.024

60
1000

30
20

40
500

180

10

l/s

20

28

10

0 Q m3/h
0 l/min
0

A
B
C

20

50

140

P kW

40
500

67

P HP

0 Q m3/h 20
0 l/min

280
260

80
20

300

67

C 218
30

20

70

73%

A
AR
C B

64
72

8
4
0

160

C 190

A
20
AR
16
B
C
12

600

65/20
NNM
65/200

2000

B 198

50

Hm

500

100 110 120 130 140

0
130

100 110 120

90
1500

H ft

60

40

NPSH m

20

30

80

40

0
8

Q m3/h 20

70

60

20

60
1000

0
8

50

12

20

40

40

30
500

80

Hm

(%)
NPSH m

m /h 20

Q l/min

A
C

80
60

16

10
8
6
4
2
0

0
0

P HP

40

NPSH ft

30
500

10

NPSH ft

P kW

m /h 20

Q l/min

40

0
130

25

20
15

10
2

0
140

64

10

P HP

0
0

P kW

H ft

50

10

5
0

Q m3/h

20

40

60

80

72.025

100

NPSH ft

10

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 2900 rpm


0 U.S. g.p.m.

200

400

600

800

45

60

140

A 176
B 167

200

400

A 210

NM
80/16
N 80/160

40

0 U.S. g.p.m.

60 65

120

600

70
73

NM(S)
80/200
N 80/200

180

74

100

25

E 140

80

20

75

50

160

B 198

Hm

76%

H ft

30

C 155
D 147

H ft

Hm

35

800

140

60

40

15
40

120

10
50
1000

Q m /h

l/min

100

150
2000

30

3000
A
B

16

P kW

12
D
E

20

12

0
0

Q m /h

l/s

50

100
1000

l/min
10

2000
20

30

3000
40

30

A
B

(%)

80
D
E

60

P kW

0
C

100
200

150

20

50

40

30
20

P HP

20

0
0

P HP

20
200

10
10

40

25

20

20

10
2
0

100

Q m3/h

50

0 U.S. g.p.m.

100

200

600
68

72

90

76

B 250

76

C 238

Hm

300

77%

80
70

250

D 226
200

60

E 207
50
150
40
68
0
0

3
Q m /h
l/min

l/s

50

100
1000

10

2000
20

30

100
200

150
3000
40

50

60

80

40

A
B 60
C
D 40

P HP

P kW

30

20

20
0

8
6
4
2
0

Q m3/h

50

100

150

72.028

25
20
15
10
5
0
200

NPSH ft

NPSH m

10
0

800

NM(S)
80/250
N 80/250
74

15

4
2

0
200

150

400

A 264

NPSH m

NPSH ft

H ft

NPSH m

65

5
0

Q m3/h

50

100

150

72.027

0
200

NPSH ft

20

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 2900 rpm


600
65

A 219

60

800
70

74

1000

76

1200

NM(S)
100/200
N 100/200
78

100

400

600

800

200

A 265

79%

B 210

0 U.S. g.p.m.

60

90

180

64

68

1000

NMS
100/250
N 100/250
74

78

160

65

20

l/s 10

20

100

150
2000

30

200

40

50

60

70

P kW

50

l/s 10

20

100

150
2000

30

200

30

40

40

50

60

70

300
5000
80

100
80

60

40

40

20

20

20
0

10

6
16

NPSH ft

26

NPSH m

10

250
4000

3000

60

10

NPSH m

H ft

Hm

50
1000

60

4
2

0 Q m3/h
0 l/min

80

40

80

40

20

150

60
300
5000

250
4000

3000

50

80

P kW

200

60
100

70

50
1000

30

8
20

6
4

10

2
0

Q m3/h 50

250

70

120

E 168

0 Q m3/h
0 l/min

H ft

40
74

74%

B 241
140

30

80

76

P HP

Hm

C 195

D 180

300

72

79

50

1200

100

150

200

250

72.033

6
300

66

P HP

400

Q m3/h 50

100

150

200

250

72.034

0
300

NPSH ft

0 U.S. g.p.m.

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


20

30

40

50
10

N4 32/125

A 130

20

A 164

50

D 118

15
4

30
55 58
60

40

50
30

N4 32/160

62

62%

B 150

62

F 103

60

Hm

10

58

H ft

Hm

0 U.S. g.p.m.10

55

20

H ft

0 U.S. g.p.m. 10

2
5
4

10

10

50

100

12
200

150

2
0,4

A
D

0,2

0,3
0,2

0,1

0
0
0

3
Q m /h 2

l/min

l/s

4
50

6
100

10

12
200

150
2

3.6

0.4

0.5

0,1

0.3

0
80

P kW

0.2

0.3
0.2

0.1

40

0.1

0
4

25

20

2
5

1
0

Q m 3/h

0 U.S. g.p.m.
15

20

10 72.076N

30

40

50

12

Hm

10

40
35 40
45 48
50

52

53%
52

30
5048

45

40

20

35

10

0
0
0

3
Q m /h 2

l/min

l/s

4
50

6
100

10

12
200

150
2

14
3.8

1.0
1.2

0.8

P kW

0.6

0.8

0.6

0.4

P HP

1.0

0.4
0.2

25

20
15

10
2
0

NPSH ft

0.2

5
0

Q m3/h 2

10

12

72.075

14

10
0

50

B 195

15

4
2

60

N4 32/200

A 204

NPSH ft

10

NPSH m

20

H ft

NPSH m

(%)

60

NPSH m

0.4
P HP

3
/h
Qm
l/min

67

5
0

Q m3/h 2

10

72.074

12

NPSH ft

P kW

0,3

0
0

P HP

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


0

U.S. g.p.m.

50

100

40

12

35

N4 40/160

A 167

10

18

0 U.S. g.p.m. 20

16

20

50

60

50

54 56

70

80

90

N4 40/200

50

58%
56

54

40

50

12

H ft

Hm

C 137

40

B 195

25
H ft

10

15
4

30

10
2

40

5
20

10

m 3/h

Q l/min

100

20
200

300

30
500

400

4
0,8

0,6

0,4

0,2

1.0

0.8

l/s

15

10

NPSH m

20

NPSH ft

10

Q m 3/h
U.S. g.p.m.

20

50

30

72.076N

1.0

25

20
15
10

2
0

5
0

Q m3/h

0 U.S. g.p.m.

N4 40/250

70

S 151
A 146

60

D 136

50

F 124

10

20

10

100

20

0
30
500
4
A
3
B 2

200

300

400

2
C

1
0
60

150

25

N4 50/125
20

15

0,8

10

0
0
0

/h
Qm
l/min

10

20
200

30

40

400

600
S
A

0,6

P kW

10

/h
Qm
l/min

P HP

0
0

100

30

20

72.077

H ft

40

15

50

Hm

15

10

80

H ft

C 227

0,4
F

0,2

0
80

1
0,8
0,6
0,4
0,2
0

60

40

20

(%)

Hm

350

1.6

20

P kW

A
B

100

A 251
B 247

(%)

25

40
20
0
4

Q m 3/h

10

20

72.076N

30

NPSH ft

25
20
15
10
5
0

NPSH m

0
9

NPSH m

20
300

0.2

25

15
250

200

NPSH ft

0
8

150

0.4

40

10
100

P HP

(%)

l/min50

0.6

20

NPSH m

Q m /h

1.2

60

0
0

P HP

0
0

P kW

0,6
0,5
0,4
0,3
0,2
0,1
0
80

P HP

P kW

10

3
2

1
0
0

68

Q m3/h

10

20

30

72.076N

40

NPSH ft

Hm

14

B 151

40

A 204

30
8

30

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


150

200

N4 50/160

A 174

10

B 162

14

B 200

30

12

C 188

Hm

15

m3/h

Q l/min

10
200

20

30
400

40

50
800

600

20

0,6

m3/h

Q l/min

10
200

20

30

40

400

50
800

600

0,5
0

0
80

(%)

2,5
2
1,5
1
0,5
0

60

A
B

40

20

0
9

0
8

25

20

25
20
15
10
5
0

6
3
0
0

Q m3/h 10

0 U.S. g.p.m.

20

50

30
100

72.076N

40
150

15

10

200

A 255

N4 50/250

B 245

50

25

20

NPSH m

20

NPSH ft

(%)

0
0
0

0
80

NPSH m

1,5

0,3

40

10

0,5

60

30

P kW

P kW

0,9

80

70

C 229

60

D 209

50

40

15

1,5

45

25

1,2

50

N4 50/200

10

P HP

1,5

0
0

200

10

150

A 209

35

20

100

35

25

50

16

H ft

Hm

0 U.S. g.p.m.

40

H ft

100

P HP

50

NPSH ft

0 U.S. g.p.m.

12

Q m3/h 10

U.S. g.p.m.

20
100

30
150

200

A 146

72.076N

40
250

50

300

N4 65/125

20

C 134

10

15

30

H ft

E 123

Hm

40

H ft

Hm

15

10

20

10

20

30
400

40

50
800

600

A
B

C
D

3
2
1
0

0
70
60

(%)

5
4

10

20

30
500

40

60
1000

50

2
1,5

A
C

0,5

A
B

20

0,5
0

80

40

70

0
A
C

60
40
20

0
4

3
0
0

Q m3/h 10

20

30

40

72.076N

NPSH ft

25
20
15
10
5
0

NPSH m

0
9

NPSH m

/h
Qm
l/min

69

A
5

1
0

50

10

Q m 3/h 10

20

30

40

50

60

72.082N

70

NPSH ft

P kW

0
0
1,5

P HP

10
200

P kW

/h
Qm
l/min

(%)

0
0

P HP

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


0

U.S. g.p.m.

100

150

200

250

300

0 U.S. g.p.m.

350

100

200

300

380

12

25

C 143

20

60 65

A 208
B 193

40

70

10

74
76%

60

10
5
0
0

30

/h
Qm
l/min

300

60
600

900

90
1500

1200

10

0
0

S
A

l/s

l/min

30
500

40

50

10

60
1000

70

15

80

90
1500

20

25
4

2
1

40

25

20
15

10

2
0

25

NPSH ft

0
8

NPSH m

20

30

Q m 3/h

0 U.S. g.p.m.

60

100

200

300

380

55 60

65

20
15

10

40

80

A 252

25

90

72.082N

5
0

20

Q m3/h

0 U.S. g.p.m.

NM4
65/25
N4
65/250

30

40

100

A 321.5

60

50

60

80 72.083 90

300

380
120

NM4
65/31
N4
65/315

64

69%

B 302

68

70

68

20

B 230

50

200

70

68

NPSH ft

(%)

80

NPSH m

20

Q m /h

60

0
0

P kW

P kW

20

P HP

30

65
74

15

50

70

H ft

B 153

Hm

15

30

H ft

Hm

NM4
65/20
N4
65/200

35

N4 65/160
NM4
65/16

A 165

P HP

S 175

10

100

68

30

60

70

C 278

64

80

H ft

50

60

72%

Hm

70

15

H ft

Hm

65

60

40

20

55

60

10

30
50

40

20

l/s

20

l/min

30
500

40

50

10

60
1000
15

70

80

90
1500

20

25

P kW

P kW

25

20

NPSH ft

NPSH m

10

NPSH m

Q m3/h

20

30

40

50

60

70

80 72.084 90

50

10

60
1000
15

70

80

90
1500

20

25

12

10

8
6
2
0

3
2
1

5
0

40

15

30
500

4
2

l/s

20

l/min

Q m /h

10

0
0

P HP

Q m /h

70

Q m3/h

20

30

40

50

60

70

80

72.087

90

12
10
8
6
4
2
0

NPSH ft

0
0

10

P HP

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


400
15
A 176

10

25

Hm

15
4
2

40
75

C 188

77%

10

73
70

0
0

/h
Qm
l/min

20
400

40

60
800

80

100
1600

1200

0
120
2000

5
4

2
1

60

20

0
0

3
Q m /h 20

l/min

l/s

40
500

60
1000

10

80

100

20

30

P kW

(%)

80
C

60

20
15

10

25

NPSH m

NPSH ft

NPSH m

25

40

0 U.S. g.p.m.

200
60 65

A 264

80

60

300
70

100

400

500

120

72.085N

600

NM4
80/25
N4
80/250

75

70

B 250
20
77%

C 231

75

60
73

50

H ft

70

15

40
10

30
20
0
0

3
Q m /h
l/min

l/s

50
500

100
1000

10

1500

150
2500

2000

20

30

40

A
6

10
8
6

P HP

4
2

25

20
15

10
2
0

NPSH ft

5
0

Q m3/h

50

100

72.088

25

20
15

10
0

80
73

Q m 3/h 20

2
1

0
8

40

Hm

20

P kW

120
2000

1500

NPSH m

30
65

75

P HP

P kW

48

10

500

NM4
80/20
N4 80/200

73

11
H ft

Hm

20

400

70

B 200

12

B 157
C 144

A 210

300

13

30
8

200
60 65

14

35

NM4
80/16
N4 80/160

0 U.S. g.p.m.100

H ft

200

P HP

U.S. g.p.m.

0
150

71

5
0

Q m /h 20
3

40

60

80

100

72.086

0
120

NPSH ft

12

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


600

700

80

1000

150
2500

2000

P kW

B
C

10

58

10

45

0
0

Q m /h

l/s

l/min

50
500

100
1000

10

1500

B
C

150
2500

2000

20

30

40

A
B

P kW

20

40
30

C
20

10
10

S
0

40
10
8

25

20

30
20

10

NPSH m

50

NPSH ft

(%)

NPSH m

60

100

30

70

150
50

4
0
80

200

55

20

12

C 367

40

16

NMS4
80/400
N4 80/400
60

50

180
3000

P HP

20

100
1500

58

600

20

40
50

55

500

30

60

45 50

400

60%

50

20

Q m /h 500
l/min

300

B 390

100

C 277

0
0

200

A 413

B 295

10

0 U.S. g.p.m.

60

120

30

Hm

70

140

N4 80/315
NM4
80/315

S 331
A 320

40

500

H ft

400

Q m3/h

10
2

50

100

150

15

P HP

300

180

72

5
0

Q m3/h

50

100

72.090

0
150

NPSH ft

200

Hm

0 U.S. g.p.m.

H ft

44

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


500

600

700

77

0 U.S. g.p.m. 200

A 265
50

300

400

55 60 65 70

500

600

700

80

60
77
75

15
30

70

81%
80

75
73
70

900

NM4
100/25
N4 100/250

40

C 185

800

80
75 77

B 250

20

80.5%
80
77

Hm

25

NM4
100/20
N4 100/200

B 202
10

800

50
70
65
60

10

40

H ft

400

60 65 70
73 75

A 219

15

300

Hm

200

H ft

0 U.S. g.p.m.

30

20
5

20
5

10

10

l/s

100
1500

1000

10

20

150
2500

2000

30

200

3000

40

50

P kW

P HP

10

150
2000

20

30

200
3000

40

50

60

A 12
B 10

6
4

25

25

20

20

15

10
2
0

40

NPSH ft

NPSH m

NPSH m

l/s

100

50

Q m /h

100

0 U.S. g.p.m. 200

150

400
65

A 328

72.091

600

70 73

75

15

10
2

5
3

0
200

800

60

5
0

600

Hm

H ft

80

800

55

60

64

65

180
160

67

C 347

140

67

40
64

69%

20

200

68

73
70

72.092

N4 100/400
NMS4
100/400

100

75

Hm

C 286

400

B 377

50
77%

150

A 405

B 306
30

100

0 U.S. g.p.m. 200

120

NM(S)4
100/315
N4 100/315

50

Q m /h
3

H ft

P kW

B
C

50
1000

l/min

Q m /h

10

5
4

0
0

60

120
100

30

60

80

40

Q m /h

l/s

50
1000

l/min
10

20

100

150
2000

30

3000
40

50

10

25

20
15

Q m3/h

50

100

150

72.093

200

NPSH m

10

NPSH ft

NPSH m

30

20

150
2000

30

200
3000

40

50

60

A
B
C

20

30

10
0

25

20
15

10
0

73

40

50

20
10

20

10

100

30

10

l/s

50
1000

40

10

0 m3/h
Q
0 l/min
0

60

20

P kW

20

200

P kW

0
0

P HP

10

P HP

50

l/min 500

NPSH ft

Q m /h

P HP

0
0

5
0

Q m3/h

50

100

150

72.094

200

NPSH ft

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


0 U.S. g.p.m.

400
60

A 271
20

600
70 74

800

1000

1200

1400

40

80
78

0 U.S. g.p.m.

NM(S)4
125/250
N4 125/250

80%

600
60

70

800
74

1000

1200

30

60

78

1400

NMS4
125/315
N4 125/315

78

B 310

B 252
C 237

400

A 330

78

100

80%

C 295

74

74
70

E 203

40

60

Hm

Hm

D 220

H ft

15

120

70

80

60

60

20

H ft

25

10
40
10

20
5

20

Q m /h

l/s

100

l/min 1000

200
3000

2000

20

40

60

300
5000

4000

80

10

80
40

20

30

C
20

20

6
4

10

NPSH m

8
NPSH ft

NPSH m

60

20

6
4

10
2

100

Q m3/h

500

72.095

300

1000
60

A 405

60

200

65

70

73

B 380

1500

200

NMS4
125/400
N4 125/400

75

76%

180
75

50

73

160

C 364

70

140
40
66

H ft

0 U.S. g.p.m.

Hm

40

300
5000

10

120
100

30
60

80
3
Q m /h 50

l/s 10

100

l/min 1000
20

150
2000

30

40

200
3000
50

250
4000
60

70

300
5000
80

350
5800
90

50

B
C

40
30

80
60
40

P HP

0
0

60

P kW

20

4000

10

20
20

10

20

6
4

10

NPSH ft

NPSH m

l/s

200
3000

2000

P kW

B
C

10

2
0

100

l/min 1000

20
P HP

P kW

20

Q m /h

30

18

0
0

P HP

0
0

Q m3/h 50

100

150

200

250

300

72.097

0
350

74

Q m3/h

100

200

300

72.096

NPSH ft

N4

End-Suction Centrifugal Pumps


standardized EN 733

Characteristic curves n 1450 rpm


1000
60 65 70
75

A 330

80

N4 150/315
NMS4
150/315

100

70 74

1500

2000

80

65

60

150

77

80

70

81%

C 370

75

20

200

NMS4
150/400
N4 150/400

77

B 390

50

Hm

Hm

1000
60 65

80

80

C 290
D 278

500

A 415

60

120

82%

B 310

30

0 U.S. g.p.m.

2000

73

40

H ft

0 U.S. g.p.m.

H ft

40

70

100

30

60

40

65

10

60
20

20

50

l/s

100
2000

l/min
20

40

200
3000
4000
60

300
5000
80

6000

400
7000

100

500
8000

A 50
B

40

20

30

l/s

100
2000

l/min
20

40

200
3000
4000
60

300
5000
80

6000

400
7000

100

500
8000

120

A 100
B
C

40

50

20

10

20

10
0

25

10

20
15

10
2

NPSH m

Q m /h

60

P kW

30

0
0

80

NPSH ft

P kW

10

120

40

NPSH m

0
30
20

5
10

5
0

Q m3/h

100

200

300

400

P HP

Q m /h

72.098

0
500

75

Q m3/h

100

200

300

400

72.099

0
500

NPSH ft

0
0

P HP

N, N4

End-Suction Centrifugal Pumps


standardized EN 733

Interchangeability of parts
Bearing housing

Pump shaft

Shaft sealing

Ball bearings

TYPE
1

N,N4 32-125
N,N4 32-160
N,N4 32-200
N,N4 40-125
N,N4 40-160
N,N4 40-200C
N,N4 40-200A-AR-B
N,N4 40-250
N,N4 50-125
N,N4 50-160
N,N4 50-200
N,N4 50-250
N,N4 65-125E
N,N4 65-125A-C
N,N4 65-160
N,N4 65-200
N,N4 65-250
N4 65-315
N,N4 80-160
N,N4 80-200
N,N4 80-250
N4 80-315
N4 80-400
N,N4 100-200
N,N4 100-250
N4 100-315
N4 100-400
N4 125-250
N4 125-315
N4 125-400
N4 150-315
N4 150-400

II

III

IV

6207 Z
6306 Z

6207 Z
3306

6309 Z
3309

6311 Z
3311

32

X
X

X
X
X

X
X

X
X

X
X

X
X

3600 rpm
32-160
40-160
50-160
65-160

3000 rpm
32-200
40-200
50-200
80-200
100-200

80-160

1800 rpm

40-250
50-250
65-200 65-250
80-250
100-250

65-315
80-400
80-315
100-315 100-400
125-250 125-315 125-400
150-315 150-400

Suction pipe: recommended minimum inside diameter (DN) for different capacities (Q)
Threaded pipe
DN
Q max

G2

G 21/2

mm

50

65

80

100

125

150

200

250

300

m /h

10,5

19

28,8

45

75

108

215

350

508

X
X

Maximum permissible rotation speed


32-125
40-125
50-125
65-125

50

40

76

N, N4

End-Suction Centrifugal Pumps


standardized EN 733

Dimensions and weights

l1

DN2

l2

h1

DN1

h2

s1

m2

14

m1

110
w

n2
n1

Shaft extension ISO 775 Parallel key UNI 6604

Flanges

PN 10, EN 1092-2
mm

mm

8
50
80 10
110 12

24 j6
32 k6
42 k6

4.93.114

DG

t
27
35
45

DN
DK
DE

rpm

DK

DE

32
40
50
65
80
100
125
150
200

76
84
99
118
132
156
184
211
266

100
110
125
145
160
180
210
240
295

140
150
165
185
200
220
250
285
340

Holes

4
4
4
4
8
8
8
8
8

mm
DN1
N, N4
N, N4
N, N4
N,
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N, N4
N4
N, N4
N, N4
N, N4
N4
N4
N, N4
N, N4
N4
N4
N4
N4
N4
N4
N4

19
19
19
19
19
19
19
23
23

18
18
20
20
22
24
24
26
30

rpm

TYPE
TIPO
B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N,
B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N4 B-N, B-N4 B-N, B-N4 B-N, B-N4 B-N4 B-N4 B-N, B-N4 B-N, B-N4 B-N4 B-N4 B-N4 B-N4 B-N4 B-N4 B-N4 -

DG

4.93.094

N n 2900
N4 n 1450

DN

32-125
32-160
32-200
40-125
40-160
40-200
40-250
50-125
50-160
50-200
50-250
65-125
65-160
65-200
65-250
65-315
80-160
80-200
80-250
80-315
80-400 (1
100-200
100-250
100-315
100-400
125-250
125-315
125-400
150-315
150-400

DN2

50

32

65

40

a
80

f
360

80
360
100

65

50

100

360

h1

h2

l1

l2

112
132
160
112
132
160
180
132

140
160
180
140
160
180
225
160
180
200
225
180
200
225
250
280
225
250
280
315
355

93
120
140
100
119
140
175
121
127
140
175
134
150
155
175
220
165
170
191
220
268
180
205
230
268
235
247
280
260
295

97
120
140
113
119
140
175
137
141
153
175
155
172
175
190
220
193
194
210
232
268
212
233
250
280
268
278
305
298
328

160
180

80

65

100
125

360
470
360

100
125
125

80
80
100

125
125
125

470
530
470

140
530
470

150
200

125
150

140
160

530
530

160
180
200
225
180
200
250
280
200
225
250
280
250
280
315
280
315

280
315
355
355
400
400
450

1) Additional size

77

m1

m2

100

70

100

70

125

95

100

70

125

95

125

95

n1

n2

190

140

240

190

210
240
265
320
240

160
190
212
250
190

s1

50

14

24

260

100

14

24

260

100

14

24

260

100

65

14

24

260

80

18

32

340

65

14

24

260

50
65

265

212

50

320

250

65

280

212

320
360
400
320
345

250
280
315
250
280

160

120

125

95

160

120

400

315

80

18

32

340

160

120

435
360

355
280

80

18

42

370

160

120

400

315

80

18

32

340

200
160

150
120

500
400

400
315

100
80

22
18

42
32

370
340

200

150

500

400

100

22

42

370

200

150

550

450

100

22

42

370

100
140

140

140
140

140
140

kg
B-N
N
B-N4 N4
30
26,5
37
33
44
38,4
32
28,4
38
33,6
47,1 40,4
63
55
42,4 36,5
45
39,2
54
47
66
57,5
48
38,7
50,6 44,5
55,5 50
103 90
149 130
61
53
93
80,5
110 95
154 134
220 192
103 89
123 104
158 138
230 200
150 129
217 189
255 222
231 201
284 247

End-Suction Centrifugal Pumps


standardized EN 733

Dimensions
FM
a

2900 rpm

g2

a1

s1

w1

4.93.070

m5

B-N,

N 32-125

B-N,

N 32-160

B-N,

N 32-200

B-N,

N 40-125

B-N,

N 40-160

B-N,

N 40-200

B-N,

N 40-250

B-N,

N 50-125

B-N,

N 50-160

B-N,

N 50-200

B-N,

N 50-250

B-N,

N 65-125

B-N,

N 65-160

B-N,

N 65-200

B-N,

N 65-250

B-N,

N 80-160

B-N,

N 80-200

B-N,

N 80-250

B-N,

N 80-250

B-N,

N 100-200

B-N,
B-N,

N 100-200
N 100-250

MOTOR
MOTORE
71 M2
80 M2
80 M2
90 S2
90 S2
90 L2
100 L2
90 L2
100 L2
112 M2
132 S2
80 M2
90 S2
90 L2
90 L2
100 L2
112 M2
132 S2
112 M2
132 S2
132 S2
160 M2
160 M2
90 L2
100 L2
112 M2
132 S2
132 S2
132 S2
160 M2
160 M2
160 M2
160 M2
160 L2
180 M2
112 M2
132 S2
132 S2
132 S2
132 S2
160 M2
160 M2
160 M2
160 L2
180 M2
180 M2
200 L2
200 L2
132 S2
160 M2
160 M2
160 L2
180 M2
200 L2
180 M2
200 L2
200 L2
225 M2
250 M2
160 L2
180 M2
200 L2
200 L2
225 M2
250 M2
280 S2

n5

n5

w1

n4

n4

n4 < 400

n4 > 480

m4

TYPE
POMPA

g2

h3

h2

DN 1

DN 2

mm
kW
0,55
0,75
1,1
1,5
1,5
2,2
3
2,2
3
4
5,5
1,1
1,5
2,2
2,2
3
4
5,5
4
5,5
7,5
11
15
2,2
3
4
5,5
5,5
7,5
11
15
11
15
18,5
22
4
5,5
7,5
5,5
7,5
11
15
15
18,5
22
22
30
37
7,5
11
15
18,5
22
30
22
30
37
45
55
18,5
22
30
37
45
55
75

DN1

DN2

h3

h2

m4

m5

w1

n4

n5

a1

g2

50
50
50
50
50
50
50
50
50
50
50
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
80
80
80
80
80
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
125
125
125
125
125
125
125

32
32
32
32
32
32
32
32
32
32
32
40
40
40
40
40
40
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50
50
50
50
65
65
65
65
65
65
65
65
65
65
65
65
65
80
80
80
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100

80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
140
140

360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
470
470
470
360
360
360
360
470
470
470
470
470
470
470
470
470
470
470
470
470
470

197
197
197
197
217
217
232
245
260
260
260
197
197
197
217
232
232
232
260
260
260
280
280
217
232
232
232
260
260
260
260
280
280
280
280
260
260
260
260
260
260
260
280
280
280
310
310
310
280
280
280
280
290
310
310
310
310
385
415
310
310
310
310
385
415
505

140
140
140
140
160
160
160
180
180
180
180
140
140
140
160
160
160
160
180
180
180
225
225
160
160
160
160
180
180
200
200
225
225
225
225
180
180
180
200
200
200
200
225
225
225
250
250
250
225
225
225
225
250
250
280
280
280
280
280
280
280
280
280
280
280
280

780
780
780
780
780
780
880
780
880
880
1020
780
780
780
780
880
880
1020
880
1020
1020
1020
1020
780
880
880
1020
1020
1020
1020
1020
1020
1020
1020
1140
880
1020
1020
1020
1020
1020
1020
1020
1020
1140
1360
1360
1360
1020
1020
1020
1020
1230
1360
1360
1360
1360
1250
1250
1230
1360
1360
1360
1250
1250
1400

750
750
750
750
750
750
850
750
850
850
990
750
750
750
750
850
850
990
850
990
990
990
990
750
850
850
990
990
990
990
990
990
990
990
1110
850
990
990
990
990
990
990
990
990
1110
1320
1320
1320
990
990
990
990
1190
1320
1320
1320
1320
840
840
1190
1320
1320
1320
840
840
940

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
20
20
20
15
15
15
15
20
20
20
20
20
205
205
20
20
20
20
205
205
230

240
240
240
240
240
240
300
240
300
300
350
240
240
240
240
300
300
350
300
350
350
350
350
240
300
300
350
350
350
350
350
350
350
350
350
300
350
350
350
350
350
350
350
350
350
400
400
400
350
350
350
350
400
400
400
400
400
480
480
400
400
400
400
480
480
510

180
180
180
180
180
180
240
180
240
240
290
180
180
180
180
240
240
290
240
290
290
290
290
180
240
240
290
290
290
290
290
290
290
290
290
240
290
290
290
290
290
290
290
290
290
340
340
340
290
290
290
290
340
340
340
340
340
430
430
340
340
340
340
430
430
450

90
90
90
90
90
90
90
90
90
90
100
90
90
90
90
90
90
90
100
100
100
100
100
90
90
90
90
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
130
130
130
100
100
100
100
100
130
130
130
130
95
95
130
130
130
130
95
95
95

85
85
85
85
85
85
100
85
100
100
100
85
85
85
85
100
100
100
100
100
100
100
100
85
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
110
110
110
100
100
100
100
110
110
110
110
110
16
16
110
110
110
110
16
16
17,5

78

s1
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
18
18
18
14
14
14
14
18
18
18
18
18
24
24
18
18
18
18
24
24
24

FM
718
752
752
809
809
809
885
809
885
882
953
752
809
809
809
885
882
953
902
973
1023
1082
1082
829
905
902
973
973
1023
1082
1082
1082
1082
1142
1189
902
973
1023
973
1023
1082
1082
1082
1142
1189
1299
1347
1347
1048
1107
1107
1167
1324
1372
1324
1372
1372
1411
1509
1263
1324
1372
1372
1411
1524
1597

H
308
317
317
325
345
345
398
373
426
437
462
317
325
325
345
398
409
434
437
462
462
517
517
345
398
409
434
462
462
497
497
517
517
517
566
437
462
462
462
462
497
497
517
517
566
596
625
625
482
517
517
517
576
625
596
625
625
723
823
547
596
625
625
723
825
937

N4

End-Suction Centrifugal Pumps


standardized EN 733

Dimensions
n
TYPE
POMPA
B-N4,
B-N4,
B-N4,

N4 32-125
N4 32-160
N4 32-200

B-N4,

N4 40-125

B-N4,

N4 40-160

B-N4,
B-N4,

N4 40-200
N4 40-250

B-N4,

N4 50-125

B-N4,
B-N4,

N4 50-160
N4 50-200

B-N4,

N4 50-250

B-N4,

N4 65-125

B-N4,

N4 65-160

B-N4,

N4 65-200

B-N4,

N4 65-250

B-N4,

N4 65-315

B-N4,

N4 80-160

B-N4,

N4 80-200

B-N4,

N4 80-250

B-N4,

N4 80-315

B-N4,

N4 80-400

B-N4,

N4 100-200

B-N4,

N4 100-250

B-N4,

N4 100-315

B-N4,

N4 100-400

B-N4,

N4 125-250

B-N4,

N4 125-315

B-N4,

N4 125-400

B-N4,

N4 150-315

B-N4,

N4 150-400

MOTOR
MOTORE
71 M4
71 M4
80 M4
80 M4
71 M4
71 M4
71 M4
80 M4
80 M4
90 S4
90 L4
100 L4
100 L4
71 M4
80 M4
80 M4
90 S4
90 S4
90 L4
100 L4
100 L4
100 L4
112 M4
80 M4
90 S4
90 S4
90 L4
100 L4
100 L4
100 L4
112 M4
132 S4
132 S4
132 M4
160 M4
90 S4
90 L4
100 L4
100 L4
100 L4
112 M4
112 M4
132 S4
132 M4
160 M4
160 L4
180 M4
180 M4
180 L4
200 L4
100 L4
112 M4
132 S4
132 M4
160 M4
160 M4
160 L4
180 M4
180 L4
200 L4
225 S4
132 S4
132 M4
160 M4
160 L4
180 M4
180 L4
200 L4
225 S4
225 M4
250 M4
180 M4
180 L4
200 L4
225 S4
225 M4
250 M4
280 S4

1450 rpm

mm
kW
0,25
0,37
0,55
0,75
0,25
0,37
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,55
0,75
1,1
1,1
1,5
2,2
2,2
3
4
0,75
1,1
1,1
1,5
2,2
2,2
3
4
5,5
5,5
7,5
11
1,1
1,5
2,2
2,2
3
4
4
5,5
7,5
11
15
18,5
18,5
22
30
3
4
5,5
7,5
11
11
15
18,5
22
30
37
5,5
7,5
11
15
18,5
22
30
37
45
55
18,5
22
30
37
45
55
75

DN1

DN2

h3

h2

m4

m5

w1

n4

n5

a1

g2

s1

fM

50
50
50
50
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
80
80
80
80
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
150
150
150
150
150
150
150
150
150
150
200
200
200
200
200
200
200

32
32
32
32
40
40
40
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50
50
65
65
65
65
65
65
65
65
65
65
65
65
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
125
125
125
125
125
125
125
125
125
125
150
150
150
150
150
150
150

80
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
160
160
160
160
160
160
160

360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
470
470
470
470
470
360
360
360
470
470
470
470
470
470
470
470
470
530
530
530
470
470
470
470
470
470
470
470
530
530
530
470
470
470
470
530
530
530
530
530
530
530
530
530
530
530
530
530

197
217
245
245
197
197
217
217
217
260
280
280
280
217
217
217
260
260
260
260
280
280
280
260
260
260
260
260
280
280
310
310
335
335
335
280
280
280
280
280
280
310
310
310
360
360
360
445
445
445
310
310
310
335
335
360
360
360
445
445
445
360
360
360
360
445
445
445
480
480
540
445
445
445
445
480
540
540

140
160
180
180
140
140
160
160
160
180
225
225
225
160
160
160
180
200
200
200
225
225
225
180
180
200
200
200
225
225
250
250
280
280
280
225
225
225
250
250
250
280
280
280
315
315
315
355
355
355
280
280
280
280
280
315
315
315
355
355
355
355
355
355
355
355
355
355
400
400
400
400
400
400
400
450
450
450

780
780
780
780
780
780
780
780
780
880
880
880
880
780
780
780
880
880
880
880
880
880
880
880
880
880
880
880
880
880
1030
1030
1030
1030
1230
880
880
880
1020
1020
1020
1030
1030
1030
1230
1230
1360
1250
1250
1250
1030
1030
1030
1030
1230
1230
1230
1360
1250
1250
1250
1030
1030
1230
1230
1250
1250
1250
1250
1250
1400
1250
1250
1250
1250
1250
1400
1400

750
750
750
750
750
750
750
750
750
850
850
850
850
750
750
750
850
850
850
850
850
850
850
850
850
850
850
850
850
850
990
990
990
990
1190
850
850
850
990
990
990
990
990
990
1190
1190
1320
840
840
840
990
990
990
990
1190
1190
1190
1320
840
840
840
990
990
1190
1190
840
840
840
840
840
940
840
840
840
840
840
940
940

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
20
20
20
20
20
15
15
15
15
15
15
20
20
20
20
20
20
205
205
205
20
20
20
20
20
20
20
20
205
205
205
20
20
20
20
205
205
205
205
205
230
205
205
205
205
205
230
230

240
240
240
240
240
240
240
240
240
300
350
350
350
240
240
240
300
300
300
300
350
350
350
300
300
300
300
350
350
350
400
400
400
400
400
350
350
350
350
350
350
400
400
400
400
400
400
480
480
480
400
400
400
400
400
400
400
400
480
480
480
400
400
400
400
480
480
480
480
480
510
480
480
480
480
480
510
510

180
180
180
180
180
180
180
180
180
240
290
290
290
180
180
180
240
240
240
240
290
290
290
240
240
240
240
290
290
290
340
340
340
340
340
290
290
290
290
290
290
340
340
340
340
340
340
430
430
430
340
340
340
340
340
340
340
340
430
430
430
340
340
340
340
430
430
430
430
430
450
430
430
430
430
430
450
450

90
90
90
90
90
90
90
90
90
100
100
100
100
90
90
90
100
100
100
100
100
100
100
100
100
100
100
100
100
100
130
130
130
130
130
100
100
100
100
100
100
130
130
130
130
130
130
115
115
110
130
130
130
130
130
130
130
130
115
115
115
130
130
130
130
115
115
115
115
115
115
115
115
115
115
115
115
115

85
85
85
85
85
85
85
85
85
100
100
100
100
85
85
85
100
100
100
100
100
100
100
100
100
100
100
100
100
100
110
110
110
110
110
100
100
100
100
100
100
110
110
110
110
110
110
16
16
16
110
110
110
110
110
110
110
110
16
16
16
110
110
110
110
16
16
16
16
16
17,5
16
16
16
16
16
17,5
17,5

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
18
18
18
18
18
14
14
14
14
14
14
18
18
18
18
18
18
24
24
24
18
18
18
18
18
18
18
18
24
24
24
18
18
18
18
24
24
24
24
24
24
24
24
24
24
24
24
24

718
718
752
752
718
718
718
752
752
829
829
905
905
738
772
772
829
829
829
905
905
905
902
772
829
829
829
905
905
905
1012
1055
1080
1130
1203
854
854
930
1040
1040
1037
1037
1080
1130
1203
1263
1339
1352
1352
1402
1040
1037
1080
1145
1218
1218
1278
1339
1367
1417
1463
1095
1145
1218
1278
1367
1367
1417
1463
1463
1561
1387
1387
1437
1483
1483
1581
1654

308
328
365
365
308
308
328
337
337
388
408
446
446
328
337
337
388
388
388
426
446
446
457
380
388
388
388
446
446
446
487
512
537
537
572
408
408
446
446
446
457
487
512
512
597
597
646
731
731
760
476
487
512
537
572
597
597
646
731
760
783
562
562
597
597
731
731
760
818
818
950
731
731
760
783
818
950
972

79

N, N4

End-Suction Centrifugal Pumps


standardized EN 733

Features

Cutting edge hydraulics


The geometry of the impeller and the pump casing are optimized to achieve maximum efficiency
and the best suction capability.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic parts in contact
with the pumped liquid allows N-N4 series pumps to be selected for use with different types of
liquids.

Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid are
dimensioned to guarantee the maximum resistence to mechanical stress. Also the casing cover is
provided with wings that prevent turbulence in the area of the mechanical sea, increasing the
reliability.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability
under all operating conditions.

80

09/2016

NR , NR4

n
n

In-line Pumps

2900 rpm
1450 rpm
Construction
Close-coupled, single-impeller, centrifugal pumps; electric
motor with extended shaft directly connected to the pump.
Pump casing with suction and delivery connections with the
same diameter and on the same axis (in-line).
Connections: Flanges PN 10, EN 1092-2.
Counterflanges (on request)
Sizes
Flanges
NR,NR4 32,40,50,65 Screwed flanges PN 16, EN 1092-1
NR4 100, NR4 125 Flanges for welding PN 10, EN 1092-1

Version with frequency converter (on request)

Applications
For clean liquids, without abrasives, which are non-aggressive for
the pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n 1450 rpm).

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.
The electropumps NR, NR4 series comply with the European Regulation no.
547/2012.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
NR :
three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% from 4 to 18,5 kW.
NRM : single-phase 230 V 10%.
4-pole induction motor, 50 Hz (n 1450 rpm).
NR4:
three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% for 4 kW.
NRM4: single-phase 230 V 10%.
Insulation class F.
Protection IP 54.
Motor suitable for operation with frequency converter from 1,1
kW for NR4 and from 2,2 kW for NR.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from 7,5 kW.
Constructed in accordance with EN 60034-1, EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component
Pump casing
Lantern bracket
Impeller
Shaft

Material
Cast iron GJL 200 EN 1561
Cast iron GJL 200 EN 1561 (Brass P-Cu Zn Pb 2 EN 1982 for NR-NR4 32,40,50)
Chrome-nickel steel AISI 303 for pumps up to 1.1 kW
Chrome steel AISI 430 for pumps from 1.5 to 18,5 kW
Carbon - Ceramic - NBR
Steel Fe 42 UNI 7070

Mecanical seal
Counterflanges

Special features on request


- Other voltages. - Protection IP 55. - Frequency 60 Hz
- Special mechanical seal. - Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 0,75 kW for NR4 and up to 1,5 kW for NR.

Coverage chart
50

100

NR n 2900 rpm

NR4

40

H
m

NR 50/250

n 1450 rpm

30

NR 65/250
50
NR 50/200

NR 32/200

40

20

NR 65/200

NR 40/200

NR4 50/250

30

NR4 65/250

NR 32/160

NR 65/160

NR 40/160
NR 50/160

NR4 32/200

10

NR4
40/200

20
NR 40/125

NR4 32/160

NR 65/125
5

NR 50/125

10

NR4
40/160

NR4 50

3
50

NR4 125
NR4 65/200

NR4
50/160

NR4
65/160

NR4 100

NR 50

NR4
50/200

6
100

/h
Qm
l/min

10

15
200

NR4 65

20
30
300 400 500

40

50
1000

100
1500

81

NR4
65/125
3

1
20

/h
Qm
l/min

3
40 50

5
100

10
150 200

20
30 40 50
1000
300 400 500

100
1500

NR EI, NR4 EI

In-line Pumps

Pumps with frequency converter


The NR EI, NR4 EI, pumps are available with power from 0,25 kW up to 11 kW, the pumps are equipped with I-MAT
installed on board which allows to realize a variable-speed system extremely compact and efficient, ideal in applications of
water supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,25 kW to 11 kW
Control range from 1750 to 2900 rpm (2-pole)
Control range from 870 to 1450 rpm (4-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases

Operating modes
H

Constant pressure mode


with pressure transducer

+
-

In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H

Proportional pressure mode


with pressure transducer

+
-

In this mode the system changes the working pressure according to the required
flow rate.

Constant flow mode


with flow meter
In this mode the system maintains a constant flow rate value in a point of the installation according to the required pressure.

Fixed speed mode


with setting of the speed preferential rotation.
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range.

H
max

+
min

Constant temperature mode


with temperature transducer
In this mode the system keeps the temperature constant inside a system by changing the speed of the pump.
82

NR

In-line Pumps

Performance n 2900 rpm


3~

NR 50D/A
NR 50C/A

3~

NR 32/160B
NR 32/160A
NR 32/200B
NR 32/200A
NR 32/200S

3~

NR 40/125C
NR 40/125B
NR 40/125A
NR 40/160B
NR 40/160A
NR 40/200B
NR 40/200A

3~

NR 50/125F
NR 50/125C
NR 50/125A/A
NR 50/160C/A
NR 50/160B/A
NR 50/160A/A
NR 50/200D/A
NR 50/200B/A
NR 50/200A/A
NR 50/250C/B
NR 50/250B/B
NR 50/250A/B

3~

230V 400V
A

2,3
3,7

1,3
2,2

P1 Max. power input.

230V P1
A

NRM 50D/A
NRM 50C/A

kW

P2
kW HP

3,6 0,72 0,45 0,6


5,7 1,13 0,75 1

4,6
7,5
9,2
11,5

2,7
4,3
5,3
6,6
9,4

230V 400V

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8 18,9

l/min

100

110

125

140

160

180

200 220

250

280

315

H
m

11,6
16,2

11
16

7
14

6
13

11

5,5

10,8 10,5 10,2 9,5 8,5


15,9 15,8 15,7 15,3 14,6

P2

m3/h

2,4

3,6

4,8

6,6

7,5

8,4

9,6

10,8

12

13,2

15

kW HP

l/min

40

50

60

80

100

110

125

140

160

180

200

220

250 280

28,1 27,9 27,6 27,3 26,5 25,6


36,8 36,3 36,1 35,7 35 34,3
42,5
41,6 41,3 40,6 39,8
51,2
49,7 49,5 48,9 48,2
58
57,4 57,2 56,7 56,1

25,1
33,8
39,3
47,9
55,8

24,3
33,2
38,5
47,2
55,1

23,4
32,4
37,7
46,5
54,4

21,9 20
31,2 29,7
36,5 35,1 33,4
45,4 44,2 42,8 41,2 37,9
53,3 52 50,5 48,8 45,9 42,6

1,5
2
3
4
5,5

1,1
1,5
2,2
3
4

H
m

Q
P2

m3/h

6,6

7,5

8,4

9,6

10,8

12

13,2

15

16,8 18,9

21

24

l/min

110

125

140

160

180

200

220

250

280

315

350

400

15,5
19,5
23,3
26,1
33,6
41,9
52,4

15,7
19,8
23,7
25,7
32,9
40,2
49,6

15,5
19,6
23,7
25,4
32,6
39,7
49,1

15,3
19,4
23,6
25,1
32,3
39,2
48,5

14,8
19,0
23,4
24,6
31,8
38,5
47,6

14,3
18,5
23,1
24,0
31,3
37,6
46,7

13,6
18,0
22,8
23,3
30,6
36,7
45,7

12,9
17,5
22,4
22,6
29,9
35,7
44,7

11,6
16,5
21,7
21,4
28,7
33,8
43,0

10,2
15,2
20,6
19,7
27,2
31,0
41,2

8,1
13,6
19,1
17,3
25,2
26,9
38,6

5,8
11,6 8,5
17,3 14,2
14,4 9,9
23,1 19,4
22,0
34,8

kW HP

4
4,6
7,5
7,5
9,2
11,5

2,3
2,7
4,3
4,3
5,3
6,6
9,4

0,75 1
1,1 1,5
1,5 2
1,5 2
2,2 3
4
3
4 5,5

230V 400V

Q
m3/h

230V 400V

H
m

Q
P2

m3/h

15

16,8 18,9

21

24

27

30

33

37,8

39

42

45

l/min

250

280

315

350

400

450

500

550

630

650

700

750

14,9
17,7
22,2
23,1
28,6
36,6
41,8
50,9
56,7
61,2
69,4
87

13,8
17,4
21,7
21,9
27,9
35,5
37,8
48,5
54,9
58,8
67
84,6

13,4
17
21,4
21,4
27,4
35,1
36,8
47,7
54,3
58
66,4
84,1

12,8
16,5
21
20,6
26,7
34,5
35,7
46,8
53,4
57,3
65,5
83,2

12,1
16
20,6
19,9
26
33,7
34,5
45,7
52,4
56,5
64,8
82,3

11
15
19,8
18,6
24,6
32,7
32,4
43,9
50,7
55
63,2
80,7

9,9
13,9
18,8
17,3
23,1
31,2
30,1
41,7
48,9
53,2
61,5
78,8

8,4
12,6
17,5
15,6
21,3
29,4
27,6
39,2
46,5
51,1
59,6
76,9

6,9
11,3
16,3
13,8
19,7
27,5
24,9
36,5
44,1
48,9
57,7
74,3

kW HP

4,7
7,5
9,2
9,2
11,5

2,7
4,3
5,3
5,3
6,6
9,4
9,4
10,9
14,3
18,5
21,5
27,5

1,1 1,5
1,5 2
2,2 3
2,2 3
4
3
4 5,5
4 5,5
5,5 7,5
7,5 10
9,2 12,5
11 15
15 20

H
m

P2

m3/h

21

24

27

30

33

37,8

42

48

54

kW HP

l/min

350

400

450

500

550

630

700

800

900 1000 1100 1150 1200

H
m

16,5
21,1
25
27,2
31,9
39
47,1
54,2
60,4
54,6
67,1
78,5

16
20,2
24,4
26,3
32
39,3
46,7
53,3
60,5
54,8
67,2
78,5

15,7
19,9
24,1
26
31,7
39
45,9
52,8
60,2
54,2
66,7
77,8

15,3
19,6
23,8
25,7
31,4
38,7
45,1
52,3
59,6
53,5
66
77,3

14,8
19,2
23,4
25,4
30,9
38,3
44,4
51,5
59
52,8
65,1
76,7

14,3
18,7
23
25
30,4
37,9
43,6
50,7
58
52
64,3
76

13,5
17,9
22,2
24,3
29,5
36,9
42
49,2
56,3
50,5
62,8
74,8

12,5
16,9
21,4
23,6
28,6
36,1
40,5
47,5
54,5
48,9
61,3
73,6

11,1
15,2
19,8
22,1
26,8
34,7
37,9
45,1
52,2
46,3
58,6
71,1

9,5
13,3
18
20,3
24,8
32,9
35,3
41,9
49,5
43,5
55,8
68,4

230V 400V
A

NR 65/125F/A
NR 65/125D/A
NR 65/125A/A
NR 65/125S/A
NR 65/160B/A
NR 65/160A/A
NR 65/200B/B
NR 65/200A/B
NR 65/200S/B
NR 65/250C/B
NR 65/250B/B
NR 65/250A/B

1~

9,2 5,3
11,5 6,6
9,4
9,4
10,9
14,3
18,5
21,5
27,5
21,5
27,5
34

P2 Rated motor power output.

8,3
9
14,1 13,5 12
10,8 10
16,6 15,7 13,6
24,3 23,4 21,3 19,1

39,7
44,8
53,8
69,8

38,8
43,1 39,4
52,6 50
68,4 65,2

2,2
3
4
4
5,5
7,5
9,2
11
15
11
15
18,5

3
4
5,5
5,5
7,5
10
12,5
15
20
15
20
25

Tolerances according to UNI EN ISO 9906:2012

83

60

7,3
11,3
15,9
18,3
22,2
30,6
32,4
38,1
46,5
40,6
52,9
65,5

66

5,3
9,1
13,7
16,1
19,7
28,1
28,3
34,5
42,7
37,3
49,7
62,2

69

72

12,4
14,7
18,3 16,7
26,7 25,3

16,8

NR4

In-line Pumps

Performance n 1450 rpm


3~

NR4 50C/A
NR4 50B/A
NR4 50A/A
NR4 65C/A
NR4 65B/A
NR4 65A/A
3~

NR4 32/160B
NR4 32/160A
NR4 32/200C
NR4 32/200B
NR4 32/200A
3~

NR4 40/160B
NR4 40/160A
NR4 40/200B
NR4 40/200A
3~

NR4 50/160C
NR4 50/160B
NR4 50/160A/A
NR4 50/200B/A
NR4 50/200A/A
NR4 50/250C/A
NR4 50/250B/A
NR4 50/250A/A
3~

NR4 65/125F
NR4 65/125D
NR4 65/125A/A
NR4 65/125S/A
NR4 65/160B/A
NR4 65/160A/A
NR4 65/200C/A
NR4 65/200B/A
NR4 65/200A/A
NR4 65/250D/A
NR4 65/250C/A
NR4 65/250B/A
NR4 65/250A/A
3~

230V 400V
A

1,4
1,4
1,4
1,4
2,1
2,1

0,8
0,8
0,8
0,8
1,2
1,2

P1 Max. power input.

NR4M 50C/A
NR4M 50B/A
NR4M 50A/A
NR4M 65C/A

P2

Q
m3/h

kW HP

l/min

H
m

3,9
4,7
5,6
3,8
4,7
5,6

16

230V P1
A

kW

2,1
2,1
2,1
2,1

0,27
0,29
0,33
0,31

0,25
0,25
0,25
0,25
0,37
0,37

1,65
1,65
1,65
2,6
3,3

0,95
0,95
0,95
1,5
1,9

0,34
0,34
0,34
0,34
0,5
0,5

P2

Q
m3/h

kW HP

l/min

230V 400V

0,37
0,37
0,37
0,55
0,75

230V 400V

0,5
0,5
0,5
0,75
1

H
m

P2

Q
m3/h
l/min

kW HP

1,65
1,65
2,6
3,3

0,95
0,95
1,5
1,9

0,37 0,5
0,37 0,5
0,55 0,75
0,75 1

H
m

P2

Q
m3/h

kW HP

l/min

H
m

230V 400V
A

1,6
2,6
3,3
5
5
6
8,6
11,1

0,92
1,5
1,9
2,9
2,9
3,5
5
6,4

0,37
0,55
0,75
1,1
1,1
1,5
2,2
3

1,65
2,6
3,3
3,3
5
5
5
6
8,6
8,6
8,6
11,1
14,4

0,95
1,5
1,9
1,9
2,9
2,9
2,9
3,5
5
5
5
6,4
8,3

Q
m3/h

kW HP

l/min

0,37
0,55
0,75
0,75
1,1
1,1
1,1
1,5
2,2
2,2
2,2
3
4

5
5
6
8,6
11,1
14,4

2,9
2,9
3,5
5
6,4
8,3

P2 Rated motor power output.

0,5
0,75
1
1
1,5
1,5
1,5
2
3
3
3
4
5,5

H
m

10

12

14

16

18

20

25

33

67

100

133

167

200

233 267

300

333

417

3,9
4,7
5,6

3,8
4,6
5,5

3,3
4,3
5,2
3,8
4,7
5,6

2,5
3,5
4,5
3,7
4,6
5,5

2,3
3,5
3,5
4,5
5,3

2
3,1
4,2
5

2,6
3,8
4,6

1,9
3,2
4,1

2,5
3,5

2,7

1,2

1,5

1,89

2,4

3,6

4,2

4,8

5,4

6,6

7,5

8,4

20

25

31,5

40

50

60

70

80

90

100

110

125

140 160

2,4

3,6

4,8

5,4

7,5

8,4

9,6

10,8

12

13,2

15

40

50

60

80

90

100

125

140

160

180

200

220

250

5,2 4,4
7,2 6,5
9,1 7,7
11,6 10,5

3,5
5,7
6,2
9,2

2,5
4,8
4,4
7,7

7,3 7,3 7,2 7,1 6,9 6,8 6,6 6,1 5,8


9,1 9,0 9,0 9,0 8,8 8,7 8,6 8,1 7,8
12,9 12,5 12,4 12,2 11,9 11,7 11,4 10,7 10,2
14,7 14,3 14,2 14,1 13,9 13,7 13,5 12,9 12,4

4,9

7,5

8,4

9,6

10,8

12

13,2

15

16,8 18,9

21

24

27

30

90

100

125

140

160

180

200

220

250

280

350 400

450

500

5,9
7,3
9,2
12,8
14,3
17,1
21
22

5,9
7,4
9,2
12,6
14,1
17
20,9
21,9

5,8
7,4
9,2
12,5
14
16,9
20,8
21,9

5,7
7,2
9,1
12,3
13,9
16,6
20,5
21,8

5,6
7,1
9
12,1
13,7
16,4
20,3
21,6

5,4
6,9
8,9
11,9
13,5
16,1
20
21,4

5,2
6,7
8,7
11,5
13,2
15,9
19,7
21,1

5
6,4
8,4
11,2
12,8
15,6
19,4
20,9

4,7
6,2
8,2
10,7
12,4
15,2
19
20,5

4,2 3,7 3,1 2,3


5,7 5,2 4,5 3,8
7,6 7,1 6,4 5,6
9,2 8,2 7,1
10
10 8,8
11,7 11
14,6 13,9 12,8 11,3
18,4 17,8 16,8 15,6
19,9 19,2 18,3 17,2

2,5
4,4 3,1
5,2
7,3
8,5 5,3
13,8 11,7
15,3 13,4

8,5
11

10,8

12

13,2

15

16,8 18,9

21

24

27

30

33

37,5

42

630

700 800

315

48

180

200

220

250

280

315

350 400

450

500

550

4,1
5,3
6,3
6,8
8,2
9,7
11,4
13,3
14,5
13,7
17,1
19,9
21,4

3,9
5
6,2
6,6
8,2
9,6
11,3
13,1
14,6
13,9
17,3
20,1
21,6

3,85
5
6,1
6,6
8,2
9,5
11,2
13
14,5
13,8
17,2
20
21,5

3,8
4,9
6
6,5
8,1
9,5
11,1
12,9
14,4
13,8
17,2
20
21,4

3,6
4,8
5,9
6,4
8
9,4
10,8
12,7
14,2
13,6
16,9
19,8
21,3

3,5
4,7
5,8
6,3
7,9
9,2
10,6
12,4
13,9
13,4
16,7
19,6
21,1

3,3
4,5
5,7
6,1
7,7
9
10,3
12,1
13,6
13,1
16,3
19,3
20,8

3
4,3
5,5
5,9
7,5
8,8
9,9
11,8
13,2
12,8
16
19
20,5

2,6
3,9
5,1
5,6
7,1
8,5
9,4
11,2
12,7
12,3
15,4
18,4
19,9

2,1
3,4
4,6
5,1
6,6
8
8,7
10,5
12
11,6
14,7
17,7
19,2

1,6
2,9
4,1
4,6
6
7,4
7,9
9,7
11,3
10,9
13,9
16,9
18,4

1
2,4 1,5
3,5 2,6 1,5
4,1 3,2 2,1
5,4 4,3 3,2
3
6,8 5,8 4,7
5,3 3,4
7
8,9 7,2 5,4
7,2
10,5 9
10,1 8,6 7,2
13 11,4 10
16,1 14,6 13,2 10,8*
17,6 16,1 14,7 12,2*

20

25

30

35

40

50

60

70

80

90

100

583

667

833 1000 1167 1333 1500 1667 1840

kW HP

l/min

333

417 500

H
m

6,6
7,5
9
10,2
12
13,6

6,6
7,5
9

6,4
7,4
8,9

1,5
1,5
2
3
4
5,5

3,3

5,4

Q
m3/h

1,1
1,1
1,5
2,2
3
4

9,6

8,1 7,9 7,9 7,7 7,6 7,4 7,2 6,9 6,6 6,1 5,6 4,4
7,6 7,2 6,6 5,6
8
8,8 8,6 8,3
9
9,2 9,3 9,3 9,2 9,1
11,5 11,3 11,3 11,2 11,1 10,9 10,7 10,5 10,2 9,9 9,5 9,1 8,5 7,4 5,7
13,2 13,2 13,2 13,1 13 12,9 12,8 12,6 12,4 12,1 11,8 11,4 10,9 10 9,1 7,5
14,6 14,5 14,5 14,4 14,3 14,2 14,1 13,9 13,8 13,5 13,2 12,8 12,3 11,4 10,5 9,1

P2

230V 400V
A

0,5
0,75
1
1,5
1,5
2
3
4

P2

230V 400V

A
NR4 100C/A
NR4 100B/A
NR4 100A/A
NR4 125C/A
NR4 125B/A
NR4 125A/A

1~

5,6 4,6
6
6,3
6,6 5,6
7
7,2
8,8 8,6 8,3 7,4
9,6
10,2 10,1 10
12 11,9 11,8 11,6
13,6 13,5 13,4 13,2

Tolerances according to UNI EN ISO 9906:2012

84

3,3
4,4
6,2
9
11
12,9

4,8
8,2 7,1 5,7
10,4 9,4 8,2
12,3 11,4 10,3

4
6,7
8,8

110

5,1
7,2

NR

In-line Pumps

Characteristic curves n 2900 rpm


18

0 U.S. g.p.m.

20

40
50

C 116

55

60

80

60 62

15

NR 50

64%

50

62
60

D 100

50

H ft

55

10

Hm

40

30

20
5
10

0
0

Q m /h

l/s

l/min

10

15

100
1

200
2

20
300

1.0

1.2
0.8

0.5

P HP

P kW

1.0
0.6

0.4
0.2
0

Q m3/h

0 U.S.g.p.m. 10
40

10

20

15

30

72.115

40

A 161,5

0
20

50

U.S.g.p.m.

20

30

40

50

60

70

60

S 200

120

NR 32/160

100

30

50

A 190

40

B 178

NR 32/200

180
160

B 144
140

120
100

H ft

30
40

80

10
20

20

2,5

0 Q l/min

5
50

7,5
100

150

A
B

2
1

0,5

0 Q l/min

10
100

15

150

200

20

250

300
S

0
80

60

40

40
20
0

10
2

2,5

7,5

10

NPSH ft

20

NPSH m

0 Q m 3/h

6
5
4
3
2
1
0

60

20

NPSH m

m 3/h

0
80

0 Q

P kW

P kW

10

200

1,5

40

0
12,5

10

0
12,5

20

6
4

10

2
0
0 Q

85

m 3/h

10

15

0
20

NPSH ft

0 Q m 3/h

P HP

60

P HP

60

H ft

20

80

NR

In-line Pumps

Characteristic curves n 2900 rpm


50

75

35

25

U.S.g.p.m.

50

75

70

100
110

A 160

NR 40/125

B 122

20

100
80

A 130

NR 40/160

100

30

60

90

B 143

C112

25

80

Hm

Hm

50

15

10

30

H ft

40

70

20
60
50

15

20

40

10

30

10

0 Q m 3/h

0 Q l/min

10
100

15

20

200

25

300

0 Q m 3/h

400

P kW

P HP

P kW

0
80

25

300

400
4

3
2
1
0

70

60
50

60

50
40

40

30

4
10

2
0

0 Q m 3/h

10

25

U.S.g.p.m.

15

50

0
25

20

75

100

NR 40/200

A 196

180
160

B 178

140

40

Hm

120

H ft

100

30

80

20

60
40

10
0 Q m 3/h

0 Q l/min

10
100

15
200

20

25

300

400

A
B

4
2

P HP

3
2
1

0
80
70
60

50

40
30

4
10

2
0 Q m 3/h

10

15

20

NPSH ft

20

0
25

86

20

6
4

10

2
0

60

50

NPSH m

8
20

NPSH ft

NPSH m

200

20

0
80

70

P kW

100

15

B
0,5

10

1,5

NPSH m

0 Q l/min

20

0 Q m 3/h

10

15

20

0
25

NPSH ft

H ft

25

U.S.g.p.m.

P HP

0
25

NR

In-line Pumps

Characteristic curves n 2900 rpm


0
25

50

U.S.g.p.m.

100

150

200

0
40

80

NR 50/125

A 134

U.S.g.p.m.

50

100

150

120

NR 50/160

A 167

70

200

20
B 151

40

60

H ft

10

C 137

20

H ft

Hm

F 115

80

50

15

100

30

60

C 123

30

40

10

20

5
20

10

10

0 Q l/min

20

30

200

40

400

50

600

800

2,5

A
C

0,5

400

40

50

600

800
6
5
4
3
2
1
0

60

40

20

40

20

NPSH m

4
10

2
0 Q m 3/h

10

20

50

U.S.g.p.m.

30

75

100

0
50

40

125

A 204

150

NR 50/200

20

6
4

10
2
0

175

0 Q m 3/h

0
100

U.S.g.p.m.

10

20

50

30

100

200

NR 50/250

A 251
160

0
50

40

150

180

B 195

50

NPSH ft

20

60

200

30

0
80

60

NPSH m

0 Q l/min

20

0
80

10

P kW

1,5

P HP

P kW

0 Q m 3/h

P HP

0 Q m 3/h

NPSH ft

300

80
250

140

D 180

120

H ft

40

60

100

40

0 Q m 3/h

10

0 Q l/min

15
200

20
300

25
400

30

35

500

0 Q l/min

600

B
B
D
D

0
80

200

30
400

40

50

600

800

40

20

B
C

15
10

0
80

A
B
C

60

60

40

20

20

0
8

6
4

10

2
0 Q m 3/h

10

15

20

25

30

35

NPSH m

20

NPSH ft

10
2
0

0
40

87

20

0 Q m 3/h

10

20

30

40

50

NPSH ft

20

12

P kW

12
10
8
6
4
2
0

P HP

NPSH m

10

16

P kW

20
0 Q m 3/h

40

P HP

20

200

150

80

10

C 215

60

100

30

10

B 227

H ft

40

NR

In-line Pumps

Characteristic curves n 2900 rpm


0
30

U.S.g.p.m.

100

150

200

250

300

350
40

S 151

NR 65/125

A 146

0 U.S.g.p.m.

100

150

90

250

300

350

NR 65/160

80

B 162

30

D 136

200
A 174

120

100

70

20

80

60

F 124

50

20

10

H ft

H ft

60
40
30

40

10
20
20
10

0 Q m 3/h
0 Q l/min

30
400

40
600

50
800

60

70

1000

1
0
80

30
400

40
600

50
800

60
1000

1200

40

A
B

2
0

A
60

40
20

10

20

6
4

10

NPSH ft

NPSH m

30

30

8
20

6
4

10

2
0 Q m 3/h

U.S.g.p.m.

20

30

100

40

150

50

200

60

250

70

300

0
80

350

0 Q m 3/h

70

U.S.g.p.m.

20

30

100

40

150

50

200

60

250

70

300

220

350

180

B 188

160

70

B 229

NR 65/250

H ft
100

C 209

180

50

160
140

40

60

120

40

10

0 Q m 3/h

20

0 Q l/min

30
400

40
600

50
800

60

70

1000

30

80

0 Q m 3/h

1200

16

20

20

S
A
B

12
8

4
0
80

20

0 Q l/min

30
400

40
600

50
800

60

70

1000

16
12

24
20
16
12
8
4
0

8
4

0
80

100
80

1200
A
B

S
A
B

60

60

P kW

16

P HP

12

260

200

60

50

20

280

P HP

30

A 245

220

140

40

80

H ft

A 200

m
40
20

40
20

8
20

6
4

10

2
0 Q m 3/h

20

30

40

50

60

70

NPSH m

NPSH ft

4
10

2
0

0
80

88

20

0 Q m 3/h

20

30

40

50

60

70

0
80

NPSH ft

200

NR 65/200

S 209

50

P kW

0
80

90

60

NPSH ft

10

NPSH m

8
4

0
80

20

10
6

4
2

S
D A
F

60

0
80

70

P kW

6
5
4
3
2
1
0

P kW

D
F

NPSH m

20

S
A

0 Q m 3/h
0 Q l/min

1200

0
80

P HP

20

P HP

NR4

In-line Pumps

Characteristic curves n 1450 rpm


30

40

64

NR4 50

20

30
60

50

B 126

16

64

60

70

80

NR4 65

18
16

74%
72

14

60

C 110

40
65 68

72

B 120

0 U.S. g.p.m.

18

65
65%

Hm

A 134.5

50 55
60

A 130

50

55

C 118

12

14
68

12

65
60

H ft

20

Hm

0 U.S. g.p.m.10

H ft

10

50

10

8
4
3

0 Q m /h 2
0 l/min
0

l/s 0.5

6
100

50
1

1.5

10

12
200

150
2

2.5

0 Q m /h
0 l/min 50
0

3.5

l/s

10
100

150

15
250

200

20
300

0.3

0.2

0.1

P kW

0.2

P HP

P kW

0.1

0.2

0.4
0.3
0.2

0.1
0.1

Q m3/h 2

10

12 72.079

89

0 Q m3/h

10

15

72.111

0
20

P HP

NR4

In-line Pumps

Characteristic curves n 1450 rpm


0

10

U.S.g.p.m.

15

20

25

30

10

30

40

30

NR4 32/160
B 150

60

NR4 32/200

18
16

25

7
20

15

40

C 184

B 194

12

H ft

50

A 200

14

H ft

10
30

8
10

20

4
5

10

0 Q m 3/h
0 Q l/min

2,5
25

5
50

7,5

75

100

125

0,2

P kW

P HP

0,1

100

150

0,6

0,4

20

0,4

A
B

10

3
2

0 Q m 3/h

2,5

10

20

U.S.g.p.m.

30

40

50

10
2
0

7,5

60

A 164

30

NR4 40/160

0 Q m 3/h

0
20

15

2,5

20

U.S.g.p.m.

30

7,5

40

10

50

18

60
60

NR4 40/200

16
25

B 149

H ft

m
5

14

A 204

12

B 195

50

40

20

15

10
30

8
10

20

4
5

10

0 Q m 3/h 2,5
0 Q l/min

50

7,5
100

10
150

12,5

15

200

0 Q m 3/h 2,5
0 Q l/min

250

0,4

50

7,5
100

10
150

12,5

P kW

0,2
0,1

250

0,8

0,4

0,4
0,2

0
80

60

0
80

60

40

20

NPSH m

10

10

15

4
3

40

20

NPSH ft

0,6

0,4

B
0,2

P HP

P kW

0,3

15

200

0,8

NPSH m

NPSH ft

NPSH ft

15

NPSH m

1
0

0,8

40

20

60

40

10

0
80

60

NPSH m

50

7,5

0,2

0
80

Q l/min

H ft

P kW

0,4

0,2

10

2,5

0,8

0,3

Q m3/h

P HP

0,4

P HP

30

15

6
4

10

0 Q m 3/h 2,5

7,5

10

12,5

15

90

0 Q m 3/h 2,5

7,5

10

12,5

15

NPSH ft

20

U.S.g.p.m.

20

A 161,5

NR4

In-line Pumps

Characteristic curves n 1450 rpm


40

U.S.g.p.m.

60

80

100

120
16

A 167

14

B 151

25

12

C 137

20

10

100

120
50

NR4 50/200
40

30

H ft

80

B 195

8
7

60

A 204

30

NR4 50/160

40

U.S.g.p.m.

15

H ft

0
10

20

6
10

4
2

10

0 Q m 3/h

5
100

15
200

20
300

0
30

25
400

0,4
0,2

500

A
B

1,2
0,8

0,4

0,4
0

A
B

40
20
0
5

20

6
4

10

NPSH ft

NPSH m

30

15

10

3
2

0 Q m 3/h

10

15

40

U.S.g.p.m.

60

20

80

0
30

25

100

120

25

80

A 251
20

NR4 50/250

70

B 247

60

C 227

40

10

H ft

50

15

30
20

5
10

0 Q m 3/h

0 Q l/min

10
100

15
200

20
300

25

30

400

500

2,8

3,2

P HP

2,4

B
C

1,6

0,8

0,8

0
80

60

A
40

20

20

6
4

10
2

0 Q m 3/h

NPSH ft

10

15

20

25

30

91

0 Q m 3/h

10

15

20

25

30

NPSH ft

%
NPSH m

400

30

60

P kW

300

25

0
80

10

200

20

1,6

NPSH m

100

15

P HP

0,6

20

10

0,8

40

0 Q l/min

500
A

60

0 Q m 3/h

1,4

0,7
0,6
0,5
0,4
0,3
0,2
0,1
0
80

P kW

P kW

0 Q l/min

10

P HP

NR4

In-line Pumps

Characteristic curves n 1450 rpm


U.S.g.p.m.

50

100

150

200

0
10

U.S.g.p.m.

50

25

S 151

m
H ft

5
15

10

20

15

F 124

25

5
4

30

B 162

20

A 146
D 136

200

NR4 65/160

8
6

150

A 174

NR4 65/125

100

H ft

0
8

10

3
2
2

0 Q l/min

20
200

30
400

600

0,4
0,2

0
80

40
20

10

10
2

30

NPSH m

20

NPSH ft

20

6
4

10

0 Q m 3/h

U.S.g.p.m.

10

20

50

30

100

0
50

40

150

0 Q m 3/h

200

U.S.g.p.m.

10

20

50

30

100

0
50

40

150

200

25

18

NR4 65/200

14

B 200

12

C 188

20
50

40

15

A 209

A 255
B 245

10
30

NR4 65/250

70

C 229

60

D 209

50

16

80

60

H ft

NPSH m

1,2
1
0,8
0,6
0,4
0,2
0

NPSH ft

S
A

A
B

0,2

20

800

60

40

20

600

0,4

60

400

0
50

40

0,6

0
80

200

30

40

10

H ft

P kW

20

0,8

0,6

0,2

10

0,8

S
A

0 Q m 3/h
0 Q l/min

800

0,6
0,4

0
50

40

P HP

10

P kW

0 Q m 3/h

P HP

30

20

20

5
10

10

0 Q m 3/h
0 Q l/min

10

20
200

30
400

0
50

40
600

0 Q l/min

800

1,2
0,8
0,4
0
80
60

200

30
400

0
50

40
600

800

3,2

C
D

0,8
0,8
0
80
60

A
B
C

40

A
B

2,4

20

C-D

40

4,8
4
3,2
2,4
1,6
0,8
0

P HP

A
B
C

P kW

2,4
2
1,6
1,2
0,8
0,4
0

P HP

P kW

1,6

A
B

20

20

0
5

10

10

3
2

NPSH m

15

NPSH ft

NPSH m

10

30

20

6
4

10

1
0

0 Q m 3/h

0 Q m 3/h

10

20

30

40

50

92

0 Q m 3/h

10

20

30

40

50

NPSH ft

NR4

In-line Pumps

Characteristic curves n 1450 rpm


200
60 65 67.5

A 174

70

300

14

NR4 100

72

B 160

60

A 210

300
65

400

500
45

68 70

NR4 125

72

B 200

12

40
72

74%

C 188

72

C 152

200

20

67.5
65

68

30
65

5
60

25
20

60

10

35
70

10

70

74%

Hm

0 U.S. g.p.m. 100

30

74

Hm

100

H ft

0 U.S. g.p.m.

H ft

10

15

l/s

30
400

40

50
800

600
8

10

12

14

60
1000
16

70
1200
18

P kW

1.6

20

20

40
500

60
1000

10

l/s

80

100
1500

20

30

3
1

120
2000

B
C

1.0

0 m3/h
Q
0 l/min
0

P kW

20

3
2

1
0

0 Q m3/h 10

20

30

40

50

60

72.113

70

93

1
0 Q m3/h

20

40

60

80

100

72.114

0
120

P HP

4
0 m3/h 10
Q
0 l/min 200

P HP

NR,NR4

In-line Pumps

Dimensions and weights

DN
h1

DN

fM

h2

mm

NR4 50A/A-B/A-C/A
NR4 65A/A-B/A-C/A
NR4 100B/A-C/A
NR4 100A/A
NR4 125C/A
NR4 125A/A-B/A
NR4 32/160A-B
NR4 32/200A-B-C
NR4 40/160A-B
NR4 40/200A-B
NR4 50/160A/A-B-C
NR4 50/200A/A-B/A
NR4 50/250B/A-C/A
NR4 50/250A/A
NR4 65/125S/A-A/A-D-F
NR4 65/160A/A-B/A
NR4 65/200C/A
NR4 65/200A/A-B/A
NR4 65/250C/A-D/A
NR4 65/250A/A-B/A

M16

Flanges PN 10, EN 1092-2

DG

DN
DK
DE

4.93.094

mm

32
40
50
65
80
100
125

DG
76
84
99
118
132
156
184

DK
100
110
125
145
160
180
210

DE
140
150
165
185
200
220
250

DN

fM

h1

h2

AD

l1

l2

kg

50
32
32
32
40
40
40
40
50
50
50
50
50
50
50
50
50
65
65
65
65
65
65
65
65

320
340
440
440
320
320
320
440
340
340
340
340
440
440
440
440
440
340
340
340
475
475
475
475
475

360
421
469
495
420
430
470
496
437
477
480
506
516
544
657
707
732
494
520
552
666
716
741
722
747

90
80
85
85
81
81
81
81
90
90
90
90
100
100
100
100
100
105
105
105
105
105
105
105
105

270
341
384
410
339
349
389
430
347
387
390
416
416
444
557
557
632
389
415
447
561
611
636
567
642

98
-

111
128
128
138
128
128
128
138
128
128
128
138
138
160
185
185
185
128
138
160
185
185
185
185
185

93
102
126
126
93
119
119
140
96
96
120
120
140
140
175
175
175
121
121
121
140
140
140
175
175

100
102
126
126
98
119
119
140
115
115
128
128
140
140
175
175
175
145
145
142
153
153
153
175
175

70
60
60
60
70
75
75
75
75
75
75
75
80
80
85
85
85
95
95
95
90
90
90
90
90

29,5-30
- 36,3
29,5-27,5-26,5
35,0
40,0
57,5 - 57
31,5-29,5
36,1
41,6
51,8-50,5
59,7
77,2-69,7
114
121
149,5
46
56,1-56,1-54,6
74-67,5
108
114
142,5
134
161-155

TYPE

DN

NR 50D/A-C/A
NR 32/160A-B
NR 32/200B
NR 32/200A-S
NR 40/125A-B-C
NR 40/160B
NR 40/160A
NR 40/200A-B
NR 50/125C-F
NR 50/125A/A
NR 50/160C/A
NR 50/160A/A-B/A
NR 50/200D/A
NR 50/200A/A-B/A
NR 50/250C/B
NR 50/250B/B
NR 50/250A/B
NR 65/125F/A
NR 65/125S/A-A/A-D/A
NR 65/160A/A-B/A
NR 65/200B/B
NR 65/200A/B
NR 65/200S/B
NR 65/250C/B
NR 65/250A/B-B/B

mm

l2

AD

l1

4.93.101.2

TYPE

Holes
N

4
4
4
4
8
8
8

19
19
19
19
19
19
19

DN

fM

h1

h2

AD

l1

l2

50
65
100
100
125
125
32
32
40
40
50
50
50
50
65
65
65
65
65
65

320
360
500
500
600
600
340
440
320
440
340
440
440
440
340
340
475
475
475
475

360
370
523
549
589
608
421
429
430
430
440
490
516
545
454
497
510
536
526
555

90
100
150
150
170
160
80
85
81
81
90
100
100
100
105
105
105
105
105
105

270
270
373
399
419
438
341
344
349
349
350
390
416
445
349
392
405
431
421
450

98
118
162
162
194
194
-

111
111
128
138
138
160
128
128
128
128
128
128
138
160
128
128
128
138
138
160

93
102
153
153
172
172
102
126
119
140
120
140
175
175
121
121
140
140
175
175

100
114
173
173
195
195
102
126
119
140
128
140
175
175
145
142
153
153
175
175

70
70
105
105
120
120
60
60
75
75
75
80
85
85
95
95
90
90
90
90

Installation

18
18
20
20
22
24
24

4.93.032.2

94

kg
24-24-24
28-28-28
59-59
67
91,5
110-108
23-22,9
31,5 - 31
43 - 39,5
37,5-35,5-33,5
56
80-77,5
93,5
42-41,5-39-37
42,7-42,5
52
64,5-60
75,5-75,5
98-85

NR EI, NR4 EI

In-line Pumps

Dimensions and weights

mm

DN
h1

DN

fM

h2

TYPE

4.93.101.2

AD

l2

l1

NR EI 50D/A-C/A
NR EI 32/160A-B
NR EI 32/200B
NR EI 32/200A-S
NR EI 40/125A-B-C
NR EI 40/160B
NR EI 40/160A
NR EI 40/200A-B
NR EI 50/125C-F
NR EI 50/125A/A
NR EI 50/160C/A
NR EI 50/160A/A-B/A
NR EI 50/200D/A
NR EI 50/200A/A-B/A
NR EI 50/250C/B
NR EI 50/250B/B
NR EI 65/125F/A
NR EI 65/125S/A-A/A-D/A
NR EI 65/160A/A-B/A
NR EI 65/200B/B
NR EI 65/200A/B
NR EI 65/250C/B

DN

fM

h1

h2

AD

AG

AS

l1

l2

50
32
32
32
40
40
40
40
50
50
50
50
50
50
50
50
65
65
65
65
65
65

320
340
440
440
320
320
320
440
340
340
340
340
440
440
440
440
340
340
340
475
475
475

399
421
469
495
420
430
470
496
437
477
480
506
516
544
657
707
494
520
552
666
716
722

90
80
85
85
81
81
81
81
90
90
90
90
100
100
100
100
105
105
105
105
105
105

270
341
384
410
339
349
389
430
347
387
390
416
416
444
557
557
389
415
447
561
611
567

270
286
286
294
286
286
286
294
286
286
286
294
294
368
393
393
286
294
368
368
393
393

190
190
210
210
190
190
210
210
190
210
210
210
210
281
281
281
210
210
281
281
281
281

105
105
118
118
105
105
118
118
105
118
118
118
118
153
153
153
118
118
153
153
153
153

93
102
126
126
93
119
119
140
96
96
120
120
140
140
175
175
121
121
121
140
140
175

100
102
126
126
98
119
119
140
115
115
128
128
140
140
175
175
145
145
142
153
153
175

70
60
60
60
70
75
75
75
75
75
75
75
80
80
85
85
95
95
95
90
90
90

kg
35,9-36,4

35,9-33,9-32,9
41,4
47,5
65-64,5
37,9-35,9
43,6
49,1
59,3-58
67,2
92-84,5
128,8
135,8
53,5
63,6-63,6-62,1
88,8-82,3
122,8
128,8
148,8

AS
AG

mm
TYPE

Flanges PN 10, EN 1092-2

DG

DN
DK
DE

4.93.094

mm
DN
32
40
50
65
80
100
125

DG
76
84
99
118
132
156
184

DK
100
110
125
145
160
180
210

DE
140
150
165
185
200
220
250

Holes
N

4
4
4
4
8
8
8

19
19
19
19
19
19
19

W
18
18
20
20
22
24
24

NR4 EI 50A/A-B/A-C/A
NR4 EI 65A/A-B/A-C/A
NR4 EI 100B/A-C/A
NR4 EI 100A/A
NR4 EI 125C/A
NR4 EI 125A/A-B/A
NR4 EI 32/160A-B
NR4 EI 32/200A-B-C
NR4 EI 40/160A-B
NR4 EI 40/200A-B
NR4 EI 50/160A/A-B-C
NR4 EI 50/200A/A-B/A
NR4 EI 50/250B/A-C/A
NR4 EI 50/250A/A
NR4 EI 65/125S/A-A/A-D-F
NR4 EI 65/160A/A-B/A
NR4 EI 65/200C/A
NR4 EI 65/200A/A-B/A
NR4 EI 65/250C/A-D/A
NR4 EI 65/250A/A-B/A

DN

fM

h1

h2

AD

AG

AS

l1

l2

kg

50
65
100
100
125
125
32
32
40
40
50
50
50
50
65
65
65
65
65
65

320
360
500
500
600
600
340
440
320
440
340
440
440
440
340
340
475
475
475
475

399
409
523
549
589
608
421
429
430
430
440
490
516
545
454
497
510
536
526
555

90
100
150
150
170
160
80
85
81
81
90
100
100
100
105
105
105
105
105
105

270
270
373
399
419
438
341
344
349
349
350
390
416
445
349
392
405
431
421
450

270
270
286
294
294
368
286
286
286
286
286
286
294
368
286
286
286
294
294
368

190
190
190
190
190
210
190
190
190
190
190
190
190
210
190
190
190
190
190
210

105
105
105
105
105
118
105
105
105
105
105
105
105
118
105
105
105
105
105
118

93
102
153
153
172
172
102
126
119
140
120
140
175
175
121
121
140
140
175
175

100
114
173
173
195
195
102
126
119
140
128
140
175
175
145
142
153
153
175
175

70
70
105
105
120
120
60
60
75
75
75
80
85
85
95
95
90
90
90
90

30,4-30,4-30,4
34,4-34,4-34,4
65,4-65,4
73,4
97,9
117,5-115,5

95

37,9-37,4
49,4-45,9
43,9-41,9-39,9
62,4
86,4-83,9
101,0
48,4-48-45,4-43,4
49,1-48,9
58,4
70,9-66,4
81,9-81,9
105,5-92,5

NR,NR4

In-line Pumps

Features

New Compact Design


A compact structure allows for simple
installation even in confined spaces

Advanced hydraulics
Optimum impeller geometry provides maximum efficiency and excellent suction characteristics.

A Unique Design
An innovative guard (patented) prevents contact with rotating parts,
providing protection to the end user
whilst allowing for inspection of the
mechanical seal.

Silent operation
Specially designed fluid ducts provide
very quiet operation

Exceptional Fluid Dynamics


The fluid dynamics through the impeller and
casing are designed to minimize losses and
increase performance.

96

09/2016

MXH 2,4,8,16

Horizontal Multi-Stage Close Coupled Pumps


in stainless steel

Construction
Horizontal multi-stage close coupled pumps in chrome-nickel
stainless steel.
Compact and robust construction, without protruding flange
and with single-piece lantern bracket and base.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump, accessible from any side (like the terminal box).

Version with frequency converter (on request)

Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial
applications, for garden use and irrigation.

Operating conditions
Liquid temperature from - 15 C to + 110 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
MXH:
three-phase 230/400 V 10% up to 3 kW;

400/690 V 10% from 3,7 to 4 kW.

Materials
Component

Material

Pump casing
Stage casing
Wear ring
Impeller
Casing cover
Spacer sleeve

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)


Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
PTFE
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Pump shaft
Plug

Chrome-nickel steel 1.4305 EN 10088 (AISI 303)


Chrome-nickel steel 1.4305 EN 10088 (AISI 303)

Mechanical seal with seat


according to ISO 3069

Ceramic alumina, carbon, EPDM


(Other materials on request)

MXHM: single-phase 230 V 10%, with thermal protector.


Capacitor inside the terminal box.
Insulation class F. Protection IP 54.
Motor suitable for operation with frequency converter from 1,8 kW.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Special features on request


- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Protection IP 55.
- Special mechanical seal
- Pump casing seal rings in FPM.
- Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 1,5 kW.

Coverage chart n 2800 rpm


0 Imp. g.p.m. 10

20

0 U.S. g.p.m.10

40

30
30

20

50
50

40

60
70

60

70

80
90

80

90
110

100

70
220
200

60

180
50

160

ft
140

m
40

120

MXH 16

30

100

MXH 8

MXH 4

MXH 2

80
20

60
40

10
20
0

0
0

m 3/h 2
l/min

4
50

6
100

10
150

12
200

14

16
250

18
300

20

22
350

24
400

26
72.978/05

97

MXH EI

Horizontal Multi-Stage Close Coupled Pumps


in stainless steel

Pumps with frequency converter


The MXH EI pumps are available with power from 0,55 kW up to 4 kW, the pumps are equipped with I-MAT installed on
board which allows to realize a variable-speed system extremely compact and efficient, ideal in applications of water
supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,55 kW to 4 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases

Operating modes
H

Constant pressure mode


with pressure transducer

+
-

In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H

Proportional pressure mode


with pressure transducer

+
-

In this mode the system changes the working pressure according to the required
flow rate.

Constant flow mode


with flow meter
In this mode the system maintains a constant flow rate value in a point of the installation according to the required pressure.

Fixed speed mode


with setting of the speed preferential rotation.
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range.

H
max

+
min

Constant temperature mode


with temperature transducer
In this mode the system keeps the temperature constant inside a system by changing the speed of the pump.
98

MXH 2,4,8,16

Horizontal Multi-Stage Close Coupled Pumps


in stainless steel

Performance n 2800 rpm


3~
MXH 202E
MXH 203E
MXH 204/A
MXH 205/A
MXH 206/B

3~
MXH 402E
MXH 403/A
MXH 404/A
MXH 405/B
MXH 406

3~
MXH 802/A
MXH 803
MXH 804
MXH 805/A

3~
MXH 1602
MXH 1603/A
MXH 1604/A
MXH 1605/A
MXH 1606/A

230 V
A
1,7
2,4
2,8
3,5
4,7

400 V
A
1
1,4
1,6
2
2,7

230 V 400 V
A
2,4
2,8
3,5
4,7
6,2

A
1,4
1,6
2
2,7
3,6

230 V 400 V
A
3,5
4,7
6,2
7,5

A
2
2,7
3,6
4,3

1~

230 V

P2

P1

MXHM 202E
MXHM 203E
MXHM 204/A
MXHM 205/A
MXHM 206

A
2,3
3
4,2
5,4
7,4

kW
0,5
0,65
0,9
1,2
1,5

1~

230 V

P1

MXHM 402E
MXHM 403/A
MXHM 404/A
MXHM 405
MXHM 406

A
3
4,2
5,4
7,4
9,2

kW
0,65
0,9
1,2
1,5
2

1~

230 V

P1

MXHM 802/A
MXHM 803
MXHM 804
MXHM 805

A
5,4
7,4
9,2
11,2

kW
1,2
1,5
2
2,5

kW
0,33
0,45
0,55
0,75
1,1

A
3,6
4,3
6,6
9,6
9,6

P1 Max. power input.


P2 Rated motor power output.

HP
0,45
0,6
0,75
1
1,5

1,5

2,5

3,5

4,25

4,8

16,6

25

33,3

41,6

50

58,3

66,6

70,8

80

22
33
45
57
68,5

20
31
42,5
53,5
65

18,5
29
40,4
50,5
61,5

17
27
37,5
47,5
58

15,3
24,5
34,5
43,5
53,5

13,4
21,7
30,8
39
48

11,4
18,6
26,7
34
43

9,3
15,5
22,4
28,5
36,5

8,2
13,8
20,1
25,8
33,5

5,6
9
14,8
19
25

3,5

4,5

l/min

H
m

Q
HP
1
1,5
2
2,5

HP
2
2,5
4
5
5,5

37,5

50

58,3

66,6

75

83,3

100

116

133

22,5
33
44,5
56,5
68,5

20
30
40,5
52
63

19
29
38
50
60

18,5
27,5
36,5
47,5
58

17,5
26
35
45,5
56

16
24,5
33
43
53,5

15
23
31
40
51

12,5
19,5
26
33,5
44

9,5
15
20
26
35

6
9,5
12,5
16,5
23

10

11

12

13

83,3

100

116

133

150

166

183

200

216

20,5
32
42,5
54

20
30,5
41
52

19
29
39
49,5

18
27,5
37
47

16,5
25,5
34,5
43,5

15
23
32
39,5

13
20
28
35

11
17
24
29,5

8,5
14
19,5
24

11

14

16

18

20

22

25

l/min

83,3

133

183

233

266

300

333

366

416

H
m

24
36
48
60
71

23
34
46,5
57,5
68

21,7
31,8
44,5
55
65

20,5
29,5
41,5
51,5
61

18,8
26,8
38
48
56

17,5
24,8
36
45
53

15,8
22,4
33
42
49

14
19,2
29
37,5
44

11,5
15,3
23
31,5
36

6,5
8,8
14
19
22

Test results with clean cold water, without gas content.


Tolerances according to UNI EN ISO 9906:2012

99

2,25

H
m

22,5
36
48
60

l/min

m3/h

P2
kW
1,5
1,8
3
3,7
4

m3/h

P2
kW
0,75
1,1
1,5
1,8

l/min

H
m

HP
0,6
0,75
1
1,5
2

kW
0,45
0,55
0,75
1,1
1,5

m 3/h

m 3/h

P2

230 V 400 V
A
6,2
7,5
11,5

+ 0,5 m security margin on NPSH-value is necessary.

MXH 2,4,8,16

Horizontal Multi-Stage Close Coupled Pumps


in stainless steel

Characteristic curves n 2800 rpm


0 U.S. g.p.m. 5

10

20

15

10

U.S. g.p.m.

30

20

70

70

MXH 206

MXH 406
200

60

200

60

MXH 205

MXH 405
50

50

150

MXH 204

m
40

ft

MXH 203

30

100

MXH 404
ft

MXH 403

30

MXH 202

20

150

m
40

100

MXH 402

20

50

50
10

10
3

m /h

0
0
50

l/min

2
20

40

60

0
60

80

40

50

30

40

8
20

NPSH
m
4

m3/h

l/min

50

100

20

NPSH
m
4

ft

ft
10

10
0

0
60

Q m3/h 1

20

U.S. g.p.m.

30

40

72.976/05

0
0

60

50

72.977/05

m /h
U.S. g.p.m.

40

60

80

100

120

200
70

MXH 1606

MXH 805

50

60
150

50

ft

MXH 803

30

200

MXH 1605

MXH 804

40

MXH 1604

150

40

100

ft

MXH 1603

100

30

MXH 802

20

MXH 1602
20

50

50

10

10
m3/h

0
0

l/min 50

100

10
150

14

12
200

0
70

60

50

50

30

Q m3/h

10

12

72.397/1

l/min 100

12

16

200

20
300

24

28

400

16
12
ft
8

0
0

NPSH
m

8
ft
4

12

NPSH
m

m3/h

70

14

100

Q m3/h

12

16

20

24

72.397/2

28

MXH 2,4,8,16

Horizontal Multi-Stage Close Coupled Pumps


in stainless steel

Dimensions and weights

fM
160

a
DN 2

(1)

127

57

DN 1

DN1 DN2
ISO 228

TYPE

4.93.209

88

10

(2)

30

28
8

112

MXH MXHM

G 1 1/4

G1

331

94

176

98,5

6,8

6,9

G 1 1/4

G1

331

94

176

98,5

7,6

7,7

MXH 204/A - MXHM 204/A

G 1 1/4

G1

381

118

193

112

10

11

MXH 205/A - MXHM 205/A

G 1 1/4

G1

405

142

193

112

11,5

12,5

MXH 402E - MXHM 402E

G 1 1/4

G1

331

94

176

98,5

7,6

7,7

MXH 403/A - MXHM 403/A

G 1 1/4

G1

357

94

193

112

9,3

10,3

MXH 404/A - MXHM 404/A

G 1 1/4

G1

381

118

193

112

10,8

11,8

MXH 802/A - MXHM 802/A

G 1 1/2

G1

381

118

193

112

10,6

11,6

DN1 DN2
ISO 228

160

h1

h2

DN 1

w1

MXH 203E - MXHM 203E

3.93.020/1

10

10,5

m1
m3

112

w1

146

kg

mm
fM

h1

h2 m1 m3

w1 MXH MXHM

G 1 1/4

G1

500 166 88 210 127 57

31 10 30,5 167 18,5 18,6

MXH 405/B - MXHM 405 G 1 1/4

G1

476 142 88 210 127 57

31 10 30,5 167 18

MXH 406 - MXHM 406 G 1 1/4

G1

500 166 88 210 127 57

31 10 30,5 167 19,5 20,5

MXH 803 - MXHM 803 G 1 1/2

G1

452 118 88 210 127 57

31 10 30,5 167 15,8 16,9

MXH 804 - MXHM 804 G 1 1/2

G1

482 148 88 210 127 57

31 10 30,5 167 18,2 19,2

MXH 805/A - MXHM 805 G 1 1/2

G1

552 178 88 210 127 57

31 10 30,5 207 21,4 22,4

DN 2

MXH 202E - MXHM 202E

TYPE

fM

(2)

146

w1

(1)

kg

mm
fM

18

MXH 1602

G2

G 1 1/2 476 128 101 210 117 70

31 10 30,5 167 18,2

MXH 1603/A

G2

G 1 1/2 516 128 101 210 117 70

31 10 30,5 207 20,8

MXH 1604/A

G2

G 1 1/2 612 166 113 235 132 70

44 12

38 232 33,8

MXH 1605/A

G2

G 1 1/2 650 203 113 235 132 70

44 12

38 232 35,5

MXH 1606/A

G2

G 1 1/2 687 241 113 235 132 70

44 12

38 232 36,4

190

fM
105
a
DN 2

127

108

DN 1

DN1 DN2
ISO 228

TYPE

(1)

mm
fM

w1

kg

MXH EI 204/A

G 1 1/4

G1

444

118

349

112

16,4

MXH EI 205/A

G 1 1/4

G1

468

142

349

112

17,9

MXH EI 403/A

G 1 1/4

G1

420

94

349

112

15,7

MXH EI 404/A

G 1 1/4

G1

444

118

349

112

17,2

MXH EI 802/A

G 1 1/2

G1

444

118

349

112

17,0

h2

m1 m3

4.93.209/1

10

88

30

28
(2)

112
146

w1

160

fM

AG
AS

TYPE
a

mm
fM

AG

AS

h1

w1

kg

MXH EI 206/B

G 1 1/4

G1

532 190 105 166

88 368 127 108 31 10 30,5 167 24,9

MXH EI 405/B

G 1 1/4

G1

508 190 105 142

88 368 127 108 31 10 30,5 167 24,4

MXH EI 406

G 1 1/4

G1

532 190 105 166

88 368 127 108 31 10 30,5 167 25,9

MXH EI 803

G 1 1/2

G1

484 190 105 118

88 368 127 108 31 10 30,5 167 22,2

MXH EI 804

G 1 1/2

G1

514 190 105 148

88 368 127 108 31 10 30,5 167 24,6

MXH EI 805/A

G 1 1/2

G1

552 190 105 178

88 368 127 108 31 10 30,5 207 27,8

MXH EI 1602

G2

G 1 1/2 508 190 105 128 101 368 117 122 31 10 30,5 167 24,6

MXH EI 1603/A

G2

G 1 1/2 516 190 105 128 101 368 117 122 31 10 30,5 207 27,2

MXH EI 1604/A

G2

G 1 1/2 627 210 118 166 113 391 132 122 44 12

38 232 41,3

112

MXH EI 1605/A

G2

G 1 1/2 665 210 118 203 113 391 132 122 44 12

38 232 43,0

146
160

MXH EI 1606/A

G2

G 1 1/2 702 210 118 241 113 391 132 122 44 12

38 232 43,9

DN 2
(1)

h1

h2

DN 1

DN1 DN2
ISO 228

3.93.020/2

(2)

10,5

m1
m3
w1

(1) Filling

10

(2) Draining

101

MXH 2,4,8,16

Horizontal Multi-Stage Close Coupled Pumps


in stainless steel

Features

3.93.001

Extra safety
against running dry, with the suction port above pump axis.

Reliable
All hydraulic parts in contact with the pumped liquid are of stainless steel.
For liquids from -15 C to 110 C.

Robust
Single-piece, thick barrel casing.

Compact
Single-piece lantern bracket and base.
Without protruding flange.

Greater protection
against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.
Greater protection against water entering the motor from outside provided by an
extension of the pump casing around the lantern bracket.

102

MXHL AISI 316

Horizontal Multi-Stage
Close Coupled Pumps
Construction
Horizontal multi-stage close coupled pumps in chromenickel-molybdenum stainless steel AISI 316L.
Compact and robust construction, without protruding flange
and with single-piece lantern bracket and base.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump, accessible from any side (like the terminal box).

6.1

Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial
applications, for garden use and irrigation.

Operating conditions
Liquid temperature from - 15 C to + 110 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
MXHL: three-phase 230/400 V 10%.
MXHLM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F. Protection IP 54.
Motor suitable for operation with frequency converter from 1,8 kW.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component

Material

Pump casing
Stage casing
Wear ring
Impeller
Casing cover
Spacer sleeve

Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)


Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
PTFE
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)

Pump shaft
Plug

Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)


Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)

Mechanical seal with seat


according to ISO 3069

Ceramic alumina, carbon, EPDM


(Other materials on request)

Special features on request


- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Protection IP 55.
- Special mechanical seal
- Pump casing seal rings in FPM.
- Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 1,5 kW.

Coverage chart n 2800 rpm


0
0

Imp. g.p.m.

10

20

10

U.S. g.p.m.

30
30

20

40

50
50

40

60

70
220
200

60

180
50

160

ft
140

m
40

120
100

30

MXHL 8

MXHL 4

MXHL 2

80
20

60
40

10
20
0

0
0

m 3/h
l/min

4
50

6
100

10
150

12
200

14
72.978/05

103

MXHL AISI 316

Horizontal Multi-Stage
Close Coupled Pumps

Performance n 2800 rpm


230 V

3~
MXHL 202E
MXHL 203E
MXHL 204/A
MXHL 205/A
MXHL 206/B

400 V

A
1,7
2,4
2,8
3,5
4,7

A
1
1,4
1,6
2
2,7

MXHL 402E
MXHL 403/A
MXHL 404/A
MXHL 405/B
MXHL 406

A
2,3
3
4,2
5,4
7,4

kW
0,5
0,65
0,9
1,2
1,5

1~

230 V

P1

MXHLM 402E
MXHLM 403/A
MXHLM 404/A
MXHLM 405
MXHLM 406

A
3
4,2
5,4
7,4
9,2

kW
0,65
0,9
1,2
1,5
2

230 V

P1

A
1,4
1,6
2
2,7
3,6

A
2,4
2,8
3,5
4,7
6,2

230 V 400 V

3~
MXHL 802/A
MXHL 803
MXHL 804
MXHL 805/A

A
3,5
4,7
6,2
7,5

P2

P1

MXHLM 202E
MXHLM 203E
MXHLM 204/A
MXHLM 205/A
MXHLM 206

230 V 400 V

3~

230 V

1~

1~

A
2
2,7
3,6
4,3

MXHLM 802/A
MXHLM 803
MXHLM 804
MXHLM 805

P1 Max. power input.


P2 Rated motor power output.

A
5,4
7,4
9,2
11,2

kW
0,33
0,45
0,55
0,75
1,1

Q
HP
0,45
0,6
0,75
1
1,5

kW
0,75
1,1
1,5
1,8

1,5

2,5

3,5

4,25

4,8

16,6

25

33,3

41,6

50

58,3

66,6

70,8

80

22
33
45
57
68,5

20
31
42,5
53,5
65

18,5
29
40,4
50,5
61,5

17
27
37,5
47,5
58

15,3
24,5
34,5
43,5
53,5

13,4
21,7
30,8
39
48

11,4
18,6
26,7
34
43

9,3
15,5
22,4
28,5
36,5

8,2
13,8
20,1
25,8
33,5

5,6
9
14,8
19
25

3,5

4,5

m 3/h
Q
HP
0,6
0,75
1
1,5
2

l/min

H
m

P2

kW
1,2
1,5
2
2,5

l/min

H
m

P2
kW
0,45
0,55
0,75
1,1
1,5

m 3/h

Q
HP
1
1,5
2
2,5

2,25

37,5

50

58,3

66,6

75

83,3

100

116

133

22,5
33
44,5
56,5
68,5

20
30
40,5
52
63

19
29
38
50
60

18,5
27,5
36,5
47,5
58

17,5
26
35
45,5
56

16
24,5
33
43
53,5

15
23
31
40
51

12,5
19,5
26
33,5
44

9,5
15
20
26
35

6
9,5
12,5
16,5
23

m3/h

10

11

12

13

l/min

83,3

100

116

133

150

166

183

200

216

22,5
36
48
60

20,5
32
42,5
54

20
30,5
41
52

19
29
39
49,5

18
27,5
37
47

16,5
25,5
34,5
43,5

15
23
32
39,5

13
20
28
35

11
17
24
29,5

8,5
14
19,5
24

H
m

Test results with clean cold water, without gas content.


Tolerances according to UNI EN ISO 9906:2012

+ 0,5 m security margin on NPSH-value is necessary.

Dimensions and weights


fM
160

a
DN 2

TYPE

fM

a
94

176 98,5

6,8

6,9

MXHL 203E - MXHLM 203E G 1 1/4 G 1

331

94

176 98,5

7,6

7,7

MXHL 204/A - MXHLM 204/A G 1 1/4 G 1

381

118

193

112

10

11

MXHL 205/A - MXHLM 205/A G 1 1/4 G 1

405

142

193

112

11,5

12,5

MXHL 402E - MXHLM 402E G 1 1/4 G 1

331

94

176 98,5

7,6

7,7

MXHL 403/A - MXHLM 403/A G 1 1/4 G 1

357

94

193

112

9,3

10,3

112

MXHL 404/A - MXHLM 404/A G 1 1/4 G 1

381

118

193

112

10,8

11,8

146

MXHL 802/A - MXHLM 802/A G 1 1/2 G 1

381

118

193

112

10,6

11,6

H
127

88

30

9
10

(2)

8
w1

ISO 228

kg

mm

DN2

331

4.93.209

28

DN1

MXHL 202E - MXHLM 202E G 1 1/4 G 1

57

DN 1

(1)

w1 MXHL MXHLM

fM
a

160
DN 2

TYPE

127

210

57

DN 1

(1)

3.93.020/1

(2)

88

10,5

31
10
w1

(1) Filling

10

30,5

112
146

(2) Draining

104

DN1

kg

mm

DN2

ISO 228

fM

w1

MXHL 206/B - MXHLM 206

G 1 1/4

G1

500

166

167

18,5

MXHL 405/B - MXHLM 405

G 1 1/4

G1

476

142

167

18

18

MXHL 406 - MXHLM 406

G 1 1/4

G1

500

166

167

19,5

20,5

MXHL 803 - MXHLM 803

G 1 1/2

G1

452

118

167

15,8

16,9

MXHL 804 - MXHLM 804

G 1 1/2

G1

482

148

167

18,2

19,2

MXHL 805/A- MXHLM 805

G 1 1/2

G1

552

178

207

21,4

22,4

MXHL MXHLM
18,6

MXHL AISI 316

Horizontal Multi-Stage
Close Coupled Pumps

Characteristic curves n 2800 rpm


0 U.S. g.p.m. 5

10

15

20

10

U.S. g.p.m.

20

30

70

70

MXHL 206

MXHL 406
200

60

200

60

MXHL 205

MXHL 405
50

50

150

MXHL 204

m
40

ft

MXHL 203

30

100

MXHL 404
ft

MXHL 403

30

MXHL 202

20

150

m
40

100

MXHL 402

20

50

50
10

10
3

m /h

0
0
50

l/min

2
20

40

60

0
60

80

40

50

30

40

8
20

NPSH
m
4

m3/h

l/min

4
50

6
100

20

NPSH
m
4

ft

ft
10

10
0

0
60

Q m3/h 1

U.S. g.p.m.

20

30

40

72.976/05

50

0
0

60
200

MXHL 805

50

150

MXHL 804

40

ft

MXHL 803

30

100

MXHL 802

20

50
10
m3/h

0
0

l/min 50

100

10
150

12

14

200

70

%
60

50
4

12

NPSH
m

8
ft
4

0
0

Q m3/h

10

12

72.397/1

14

105

Q m 3/h

72.977/05

6.1

MXHL AISI 316

Horizontal Multi-Stage
Close Coupled Pumps

Features

3.93.001

Extra safety
against running dry, with the suction port above pump axis.

Reliable
All hydraulic parts in contact with the pumped liquid are of stainless steel.
For liquids from -15 C to 110 C.

Robust
Single-piece, thick barrel casing.

Compact
Single-piece lantern bracket and base.
Without protruding flange.

Greater protection
against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.
Greater protection against water entering the motor from outside provided by an
extension of the pump casing around the lantern bracket.

106

MXH 20,32,48

Horizontal Multi-Stage
Close Coupled Pumps
Construction
Horizontal multi-stage close coupled pumps in chrome-nickel
stainless steel.
Compact and robust construction,with compact lantern
bracket and motor with feet.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump,
accessible from any side (like the terminal box).

6.2

Version with frequency converter (on request)

Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for civil and industrial applications, for garden
use and irrigation.

Operating conditions
Liquid temperature from - 15 C to + 110 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing: 10 bar.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
MXH: three-phase 230/400 V 10% up to 3 kW;

400/690 V 10% from 4 to 7,5 kW.

Insulation class F. Protection IP 54.


Motor suitable for operation with frequency converter.
Classification scheme IE2 up to 5,5 kW, IE3 for 7,5 kW.
Constructed in accordance with: EN 60034-1;
EN 60034-30.

Materials
Component

Material

Pump casing
Stage casing
Wear ring
Impeller
Casing cover
Spacer sleeve

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)


Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
PTFE
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Pump shaft
Plug

Chrome-nickel steel 1.4401 EN 10088 (AISI 316)


Chrome-nickel steel 1.4305 EN 10088 (AISI 303)

Mechanical seal with seat


according to ISO 3069-KU

Ceramic alumina, carbon, EPDM


(Other materials on request)

Special features on request


- Pump with Victaulic ports (MXH-V).
- Pump with flanged ports (MXH-F).
- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Protection IP 55.
- Special mechanical seal
- Seal rings in FPM.
- Higher or lower lambient temperatures.

Coverage chart n 2900 rpm


90

Imp. g.p.m.

U.S. g.p.m.

50

100

50

200

150

100

150

200

250
250

300

80
70
200

60

H
m

ft

40

MXH 20

MXH 32
100

30

MXH 48
20
10
0

0
0

m 3/h
l/min

10

20
200

30
400

40
600

107

50
800

60
1000

72.978/05

70

MXH EI

Horizontal Multi-Stage
Close Coupled Pumps

Pumps with frequency converter


The MXH EI pumps are available with power from 1,1 kW up to 7,5 kW, the pumps are equipped with I-MAT
installed on board which allows to realize a variable-speed system extremely compact and efficient, ideal in
applications of water supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 1,1 kW to 7,5 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases

Operating modes
H

Constant pressure mode


with pressure transducer

+
-

In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H

Proportional pressure mode


with pressure transducer

+
-

In this mode the system changes the working pressure according to the required
flow rate.

Constant flow mode


with flow meter
In this mode the system maintains a constant flow rate value in a point of the installation according to the required pressure.

Fixed speed mode


with setting of the speed preferential rotation.
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range.

H
max

+
min

Constant temperature mode


with temperature transducer
In this mode the system keeps the temperature constant inside a system by changing the speed of the pump.
108

MXH 20,32,48

Horizontal Multi-Stage
Close Coupled Pumps

Performance n 2900 rpm


230 V

3~

400 V
A
2,7
4,3
6,6
9,6
10,8

A
4,6
7,5
11,5
-

MXH 2001
MXH 2002
MXH 2003
MXH 2004
MXH 2005

230 V

400 V

MXH 3201/A
MXH 3202/A
MXH 3203/A
MXH 3204/A

A
9,2
-

A
5,3
9,6
10,8
14,3

3~

230 V

400 V

HP
1,5
2,5
4
5,5
7,5

Q
HP
3
5,5
7,5
10

10

12

14

16

18

20

22

24

l/min

133,3

166,6

200

233

266

300

333

366

400

17
34
51
69
86

15,6
31,5
49
65
81

15,2
30,4
47,5
63
79

14,5
29,2
46
61
76

13,6
27,5
44
58,5
73

12,4
25,7
41,3
55
69

11,2
23,6
38
51
63

9,6
21
33
44,7
55

7,8
17,8
27
37
46

5,2
13
20
27
33

Q
HP
4
7,5
10

6.2

m /h

15

21

24

27

30

33

36

39

44

50

l/min

250

350

400

450

500

550

600

650

733

833

18,4
37
55,5
74,5

16,3
33
50
67

15,3
31
47
63

14,8
30
45,5
61

14
28,5
43
59

13
27
40,5
56

12
25
38
53

10,8
23
35
49

9,3
20,5
31
44

6
15
23
34

7,5
10
16,5

H
m

P2
kW
3
5,5
7,5

m 3/h

H
m

P2
kW
2,2
4
5,5
7,5

A
6,6
10,8
14,3

A
11,5
-

kW
1,1
1,8
3
4
5,5

3~

MXH 4801/A
MXH 4802/A
MXH 4803/A

P2

m 3/h

21

27

33

39

45

48

51

54

60

66

l/min

350

450

550

650

750

800

850

900

1000

1100

20
41
60,5

18
35,3
53

17
33
50

16
30,5
46

14,5
27,5
42,5

12,5
24,5
38

11,5
22,5
35

10,5
21
32,5

9,5
19
29

7
14
22,5

7,5
16

H
m

P2 Rated motor power output.


Test results with clean cold water, without gas content.
Tolerances according to UNI EN ISO 9906:2012

+ 0,5 m security margin on NPSH-value is necessary.

Dimensions and weights


fM

Threaded
ports
MXH

250

s1

DN1
DN2
ISO 228

MXH 2001
MXH 2002
MXH 2003
MXH 2004
MXH 2005
MXH 3201/A
MXH 3202/A
MXH 3203/A
MXH 3204/A
MXH 4801/A
MXH 4802/A
MXH 4803/A

b1
w1

m5
m4

TYPE

g2*

g2

150

DN1

140

DN2

n5
n4

mm
n4

n5

w1

b1

s1

g2

kg

G2

G 1 1/2 467

127

280

205

175

170

130

15

54

10

95

6*

26

G2

G 1 1/2 507

127

280

205

175

170

130

15

54

10

95

6*

30

G2

G 1 1/2 540

146

290

205

175

180

140

15

54

10

112

6*

38

G2

G 1 1/2 574 180,5 290

205

175

180

140

15

54

54

112

6*

39

G2

G 1 1/2 630,5 215

310

280

250

258

190

15

68

68

84

38

50,5

280

205

175

170

130

15

54

10

95

6*

29,4

G 2 1/2

G2

fM

m4

m5

503,5 123

G2

517,5 123

290

205

175

180

140

15

54

10

112

6*

38,5

G2

584,5 169

310

280

250

258

190

15

68

12

84

38

50

DN

G2

630,5 215

310

280

250

258

190

15

68

12

84

38

57,5

DG

G3

G 2 1/2 547,5 138,5 290

205

175

180

140

15

54

10

128,5

6*

38

DK

G3

G 2 1/2 568,5 138,5 310

280

250

258

190

15

68

12

100

38

49,5

DE

G3

G 2 1/2 630,5 200

310

280

250

258

190

15

68

12

100

38

58

Flanged ports
MXH-F

fMV

fMF
aF
DN2

mm

mm

fMV

aV

76,1 (DN65) 60,3 (DN50)

541

160

76,1 (DN65) 60,3 (DN50)

555

160

76,1 (DN65) 60,3 (DN50)

622

206

76,1 (DN65) 60,3 (DN50)

668

252

88,9 (DN80) 76,1 (DN65)

585

175

88,9 (DN80) 76,1 (DN65)

606

175

88,9 (DN80) 76,1 (DN65)

668

237

109

175

DN2

150

MXH-V 3201/A
MXH-V 3202/A
MXH-V 3203/A
MXH-V 3204/A
MXH-V 4801/A
MXH-V 4802/A
MXH-V 4803/A

DN1

DN1

177

TYPE

mm

N.

40 150 110 81
50 165 125 99
65 185 145 118

4
4
4

19
19
19

80 200 160 132

19

* ASME 150 lb (ex ANSI 150 lb)

Victaulic ports
MXH-V
DN2

150

Holes
Fori

G 2 1/2
G 2 1/2

EN 1092-2

DN DE DK DG

G 2 1/2

aV

DN1

Flanges*
Flange*

TYPE
MXH-F 2001
MXH-F 2002
MXH-F 2003
MXH-F 2004
MXH-F 2005
MXH-F 3201/A
MXH-F 3202/A
MXH-F 3203/A
MXH-F 3204/A
MXH-F 4801/A
MXH-F 4802/A
MXH-F 4803/A

mm

DN1 DN2
mm

mm

fMF

aF

50

40

502

161,5

50

40

542

161,5

50

40

575

180,5

50

40

624

215

50

40

665

249,5

65

50

531

151

65

50

545

151

65

50

612

197

65

50

658

243

80

65

565

156

80

65

586

156

80

65

648

218

MXH 20,32,48

Horizontal Multi-Stage
Close Coupled Pumps

Dimensions and weights


Threaded ports
MXH EI

AG
AS

fM

250

s1
m5
m4

DN1
DN2
ISO 228

TYPE
MXH EI 2001
MXH EI 2002
MXH EI 2003
MXH EI 2004
MXH EI 2005
MXH EI 3201/A
MXH EI 3202/A
MXH EI 3203/A
MXH EI 3204/A
MXH EI 4801/A
MXH EI 4802/A
MXH EI 4803/A

G2

175
150

DN1

n5
n4

mm
fM

AG

AS

h2

m4

m5

n4

n5

w1

b1

s1

g2

kg

G 1 1/2 499

190

105

127

436

192

205

175

170

130

15

54

10

95

6*

32,4

G2

G 1 1/2 532

210

118

127

436

192

205

175

170

130

15

54

10

95

6*

36,4

G 1 1/2 572

210

118

146

444

192

205

175

180

140

15

54

10

112

6*

45,5

G2

G 1 1/2 606

210

118

G2

G 1 1/2 630,5

210

118

180,5 444
215

472

192

205

175

180

140

15

54

54

112

6*

46,5

192

280

250

258

190

15

68

68

84

38

65,3

G 2 1/2

G2

528,5

210

118

123

436

197

205

175

170

130

15

54

10

95

6*

35,8

G 2 1/2

G2

594,5

210

118

123

444

197

205

175

180

140

15

54

10

112

6*

46,0

G 2 1/2

G2

594,5

210

118

169

472

197

280

250

258

190

15

68

12

84

38

64,8

G 2 1/2

G2

665,5

281

153

215

518

197

280

250

258

190

15

68

12

84

38

72,3

G3

G 2 1/2 579,5

210

118

138,5 444

202

205

175

180

140

15

54

10

128,5

6*

45,5

G3

G 2 1/2 568,5

210

118

138,5 472

202

280

250

258

190

15

68

12

100

38

64,3

G3

G 2 1/2 665,5

281

153

202

280

250

258

190

15

68

12

100

38

72,8

TYPE

200

518

MXH-F EI 2001
MXH-F EI 2002
MXH-F EI 2003
MXH-F EI 2004
MXH-F EI 2005
MXH-F EI 3201/A
MXH-F EI 3202/A
MXH-F EI 3203/A
MXH-F EI 3204/A
MXH-F EI 4801/A
MXH-F EI 4802/A
MXH-F EI 4803/A

mm

Flanges*
Flange*

mm

DN1 DN2
mm

fMF

DN2

b1
w1

G2

Flanged ports
MXH-F EI
aF

g2*

g2

150

DN1

h2

DN2

fMF

50

40

534

161,5

50

40

567

161,5

50

40

607

180,5

Holes
Fori

DN DE DK DG
DN

50

40

641

215

DG

50

40

665

249,5

DK
DE

65

50

556

151

65

50

622

151

65

50

622

197

65

50

693

243

80

65

597

156

80

65

586

156

80

65

683

218

110

EN 1092-2

aF

N.

40 150 110 81
50 165 125 99
65 185 145 118

4
4
4

19
19
19

80 200 160 132

19

* ASME 150 lb (ex ANSI 150 lb)

MXH 20,32,48

Horizontal Multi-Stage
Close Coupled Pumps

Characteristic curves n 2900 rpm


0 U.S. g.p.m. 25

50

100

75

0 U.S. g.p.m. 50

90

100

200

150

80

MXH 2005

ft

80
70

MXH 2004

200

60
200

60

MXH 3203

H
m

MXH 2003

H
m

ft

MXH 3204

70

6.2

40

MXH 3202

40

MXH 2002
100

30
20

100

30
20

MXH 2001

MXH 3201

10

10
0

0
0

m 3/h 5
Q

l/min

10
100

15
200

0
0

25

20
300

400

70

m 3/h 10
Q l/min

200

20
300

70

50
%
30

0,8

0,6
Pst
kW
0,2

50

400

500

50

40
600

700

800
2,5

Pst

30

2
1,5
Pst
kW
0,5

Pst

%
30

8
20

NPSH
4

0
Q m 3/h 5

U.S. g.p.m.

10

100

15

200

150

72.974

20

250

10

m
0

0
0

ft

10

20

NPSH

ft

25

0
0

Q m 3/h 10

20

30

40

72.974

50

300

70
200

60

MXH 4803

H
m

ft

40

MXH 4802
100

30

MXH 4801

20
10

Designation

0
m3/h 10

0
0

30

20

l/min 200

400

600

70
60
%
50

40

50
800

0
70

60

MXH-F EI 3204 *

1000

Series
No code = threaded ports
Victaulic ports
Flanged ports
With frequency converter I-MAT
Rated capacity in m3/h
Number of stages

40

2,5
Pst
2
kW
1,5

30

Pst

ft

6
NPSH
4
m
2

ft

Construction variants
special seal code (no code = standard seal)

10

0
0 Q m3/h 10

20

30

40

50

60

72.1035

V
F

70

111

MXH 20,32,48

Horizontal Multi-Stage
Close Coupled Pumps

Features

Flexibility
Three versions of ports: threaded, flanged and Victaulic.

Extra safety
With front axis suction port for optimum suction conditions.

Reliable
All hydraulic parts in contact with the pumped liquid are made in stainless steel.
For liquids from -15 C to 110 C.

Robust
Single-piece, thick barrel casing, open on one side only, with reinforced threaded
ports.

Compact
The bracket between pump and motor is extremely compact.

Greater protection
Against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.

112

09/2016

MXP

Horizontal Multi-Stage Close Coupled Pumps


Construction
Horizontal multi-stage close coupled pump.
Single-piece barrel casing in chrome-nickel stainless
steel, with front suction port above pumps axis and
radial delivery at top.
Stages in Noryl.

Applications
For water supply.
For domestic use, for garden use and irrigation.

Operating conditions
Liquid temperature: 0 C to +50 C.
Ambient temperature up to +40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
MXP:
three-phase 230/400 V 10%.
MXPM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component

Material

Pump casing
Casing cover

Cr-Ni steel 1.4301 EN 10088 (AISI 304)


Cr-Ni steel 1.4301 EN 10088 (AISI 304)

Pump Shaft
Plug

Chrome steel 1.4104 EN 10088 (AISI 430)


Cr-Ni steel 1.4305 EN 10088 (AISI 303)

Stage casing
Impeller

PPO-GF20 (Noryl)
PPO-GF20 (Noryl)

Mechanical seal

Carbon - Ceramic - NBR

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Motor suitable for operation with frequency converter.

Characteristic curves n 2800 rpm


0 U.S. g.p.m. 5

10

15

0
60

20

60

MXP 205
H

150

MXP 204

30

MXP 203

20

MXP 202

ft
100

30

20

MXP 405

50

50
m
40

10

U.S. g.p.m.

150

m
40

MXP 404
ft

MXP 403

30

100

MXP 402

20

50

50
10

10

0
0
m3/h 1
Q l/min
0
20
45
40

2
40

60

5
80

NPSH
m

NPSH

0
0
55

m3/h

Q l/min

6
100

50

NPSH

NPSH
m
2

50

%
40

30
25
0

Q m3/h 1

72.1136

35
0

113

Q m3/h

72.1137

0
8

MXP

Horizontal Multi-Stage Close Coupled Pumps

Performance n 2800 rpm


230 V 400 V

3~

MXP 202
MXP 203
MXP 204/A
MXP 205

A
1,7
2,4
2,8
3,5

A
1
1,4
1,6
2

1~

230 V

P1

MXPM 202
MXPM 203
MXPM 204/A
MXPM 205

A
2,3
3
4,2
5,4

kW
0,45
0,63
0,8
1,2

1~

230 V

P1

MXPM 402
MXPM 403/A
MXPM 404/A
MXPM 405

A
3
4,2
5,4
7

kW
0,61
0,9
1,2
1,5

230 V 400 V

3~
MXP 402
MXP 403/A
MXP 404/A
MXP 405

A
2,4
2,8
3,5
4,5

A
1,4
1,6
2
2,6

P1 Max. power input.


P2 Rated motor power output.

P2
kW
0,33
0,45
0,55
0,75

Q
HP
0,45
0,6
0,75
1

P2
kW
0,45
0,55
0,75
1,1

1,5

l/min

16,6

25

Q
HP
0,6
0,75
1
1,5

m3/h

21,5
32,5
m
45
56

19
29
40
50

2,5

33,3 41,6

3,5

50

58,3 66,6 75

4,5

17,5 16 14,5 12,5 10,5 8,5 6,5


11
25 22,5 20 17 14
27
37,5 35 32 28,5 25 21,5 17
46,5 43,5 40 35,5 31 26,5 21

5,4

83,3 90
7,5
13
16

9
11

m 3/h

2,25

3,5

4,5

7,2

l/min

37,5

50

58,3

66,6

75

83,3

100

120

22
33,5
46
56

19
30
40
50

17,5
28
38
47

16,5
26,5
36,5
45

15
25
34
42

14
23
32
39,5

12,5
21,5
29,5
36

9,5
17
24
29,5

5
10
16
20

H m

Test results with clean cold water, without gas content.


+ 0,5 m security margin on NPSH-value is necessary.

Tolerances according to UNI EN ISO 9906:2012


For capacities over 4 m3/h use a suction pipe G 1 1/4 (DN 32).

Dimensions and weights


fM
115

mm

161

MXP 202 - MXPM 202


MXP 203 - MXPM 203
MXP 204/A - MXPM 204/A
MXP 205 - MXPM 205
MXP 402 - MXPM 402
MXP 403/A - MXPM 403/A
MXP 404/A - MXPM 404/A
MXP 405 - MXPM 405

177
H

116

G1

ISO 228

ISO 228

95
210

10

4.93.281

33
w1

kg

TYPE
TIPO

G1

30

112
146

fM
362
362
391
391
362
391
391
421

H
176
176
192
192
176
192
192
192

w1
102
102
112
112
102
112
112
142

MXP
5,9
6,6
8,7
9,5
6,5
8,6
9,5
13,5

MXPM
6
6,7
9,6
10,5
6,6
9,5
10,5
13,5

Features

Extra safety
against running dry, with the suction port
above pump axis.
Robust
Single-piece barrel casing.
Compact
Single-piece lantern bracket and base.
Low noise
with the water-filled shroud around the stages.
3.93.123

114

09/2016

MGP

Horizontal Multi-Stage Close Coupled Pumps


Construction
Horizontal multi-stage close coupled pump.
Single-piece barrel casing in cast iron, with front suction
port above pumps axis and radial delivery at top.
Stages in Noryl.

Applications
For water supply.
For domestic use, for garden use and irrigation.

8
Operating conditions
Liquid temperature: 0 C to +50 C.
Ambient temperature up to +40 C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
MGP:
three-phase 230/400 V 10%.
MGPM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Component

Material

Pump casing

Cast iron GJL 200 EN 1561

Casing cover

Cr-Ni steel 1.4301 EN 10088 (AISI 304)

Pump Shaft

Chrome steel 1.4104 EN 10088 (AISI 430)

Stage casing

PPO-GF20 (Noryl)

Special features on request

Impeller

PPO-GF20 (Noryl)

Mechanical seal

Carbon - Ceramic - NBR

- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Motor suitable for operation with frequency converter.

Characteristic curves n 2800 rpm


0 U.S. g.p.m. 5

10

15

20

0
60

60

MGP 205

50

30

MGP 203

20

MGP 202

30

MGP 405

150

MGP 204

20

10

50

H
m
40

U.S. g.p.m.

150

MGP 404

40

ft
100

ft

MGP 403

30

100

MGP 402

20

50

50
10

10

0
0

m /h 1
l/min

20

2
40

60

0
55

80

45

NPSH
m

40

NPSH

m3/h

Q l/min

50

Q m3/h 1

72.976

NPSH

NPSH
m
2

50

35
0

115

m3/h

100

40

30
25

72.977

0
8

MGP

Horizontal Multi-Stage Close Coupled Pumps

Performance n 2800 rpm


230 V 400 V

3~

A
1,7
2,4
2,8
3,5

MGP 202
MGP 203
MGP 204
MGP 205

1~

A
1
1,4
1,6
2

A
2,4
3
3,5
4,5

MGP 402
MGP 403
MGP 404
MGP 405

P1

A
2,3
3
3,3
5,4

kW
0,45
0,63
0,75
1

230 V

P1

A
3
3,5
5,4
7

kW
0,61
0,85
1,2
1,5

MGPM 202
MGPM 203
MGPM 204
MGPM 205

230 V 400 V

3~

230 V

1~

A
1,4
1,73
2
2,6

MGPM 402
MGPM 403
MGPM 404
MGPM 405

P1 Max. power input.


P2 Rated motor power output.

P2
kW
0,33
0,45
0,55
0,75

Q
HP
0,45
0,6
0,75
1

l/min

16,6

P2
kW
0,45
0,55
0,75
1,1

m3/h

Q
HP
0,6
0,75
1
1,5

21,5
32,5
m
43
56

19
29
38
50

1,5
25

2,5

33,3 41,6

3,5

50

58,3 66,6 75

4,5

5,4

83,3 90

17,5 16 14,5 12,5 10,5 8,5 6,5


11 7,5
25 22,5 20 17 14
27
35,5 32,7 29,7 26,5 23 19,2 15,2 11
46,5 43,5 40 35,5 31 26,5 21 16

7,5
11

m 3/h

2,25

3,5

4,5

7,2

l/min

37,5

50

58,3

66,6

75

83,3

100

120

22
32
46
56

19
27,5
40
50

17,5
25,5
38
47

16,5
23,7
36,5
45

15
22
34
42,5

14
20
32
39,5

12,5
18
29,5
36

9,5
13,3
24
29

5
7
15
19

H m

Test results with clean cold water, without gas content.


+ 0,5 m security margin on NPSH-value is necessary.

Tolerances according to UNI EN ISO 9906:2012


For capacities over 4 m3/h use a suction pipe G 1 1/4 (DN 32).

Dimensions and weights


fM
115
G1 ISO 228

Net weight

161

mm

116

ISO 228

G1

51

TYPE

4.93.367

10

33
95
210

30

112

w1

146

Features
Extra safety

Pi sicurezza

against
dry, witha the
suction
above
contro running
il funzionamento
secco,
con laport
bocca
pump
axis.sopra l'asse della pompa.
aspirante

Robust
Robusta

Single-piece
casing.
Corpo pompabarrel
in un solo
pezzo aperto su un solo
lato.
Compact

Single-piece
Compattalantern bracket and base.
Raccordo
pompa-motore e base in un solo pezzo.
Low
noise

with the water-filled shroud around the stages.

Bassa rumorosit

con il mantello d'acqua attorno agli stadi.

116

MGP 202 - MGPM 202


MGP 203 - MGPM 203
MGP 204 - MGPM 204
MGP 205 - MGPM 205
MGP 402 - MGPM 402
MGP 403 - MGPM 403
MGP 404 - MGPM 404
MGP 405 - MGPM 405

fM
362
362
362
391
362
362
391
421

H
176
176
176
192
176
176
192
192

kg
w1
102
102
102
112
102
102
112
112

MGP MGPM
8,9
9
9,3
9,4
10,3
10,4
13,5
12,5
9,5
9,6
10,3
10,4
12,5
13,5
16,5
16,5

09/2016

MXSU

Vertical multi-stage close coupled pumps


Construction
Vertical multi-stage close coupled pumps in chrome-nickel
stainless steel, with motor shields in brass.
Suction connection on the lower casing and delivery connection
on the top casing. Motor cooled by the pumped water passing
between the motor jacket and the external jacket.
Double mechanical shaft seal with interposed oil chamber.

Applications
For clean water without abrasives or additives aggressive for
the materials of the pump.
For domestic, civil and industrial applications.
For installation in confined space with minimum ventilation.
For installation in locations subject to risk of temporary
flooding.
For installation in areas exposed to water jetting.
When low-noise operation is required.

Operating conditions
Water temperature up to 35 C.
Maximum permissible pressure in the pump casing: 10 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
MXSU : three-phase 230 V 10%;
three-phase 400 V 10%.
MXSUM : single-phase 230 V 10% , with thermal protector.
Control box with capacitor, on request.
Cable: H07RN8-F, 4 G 1 mm2, length 2 m.
Insulation class F.
Protection IP 68.
Triple impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Component
External jacket
Suction casing
Stage casing
Impeller
Oil chamber cover
Spacer sleeve
Motor jacket
Shaft
Motor shield
Elbow
Upper mechanical seal
Lower mechanical seal
Seal lubrication oil

Material

Chrome-nickel steel
1.4301 EN 10088 (AISI 304)

Chrome-nickel steel 1.4305 EN 10088 (AISI 303)


Brass P- Cu Zn 40 Pb 2 UNI 5705
Brass P- Cu Zn 40 Pb 2 UNI 5705 nickel-plated
Steatite, carbon, NBR
Ceramic alumina, silicon carbide, NBR
Oil for food machinery and pharmaceutic use

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Motor suitable for operation with frequency converter.

Coverage chart n 2900 rpm


0

Imp g.p.m.

U.S. g.p.m.

10

20

10

30
30

20

40
50

40

70
200

60

50

150

m
40

ft
100

30

MXSU 2
MXSU 4

20

MXSU 8
50

10

0
0

m3/h

Q l/min

4
50

6
100

10
150

0
12
200
72.979

117

MXSU

Vertical multi-stage close coupled pumps

Performance n 2900 rpm


3~

230 V 400 V
A

230 V

1~

Capacitor

P1

kW

P2
kW

m3/h

l/min

1,5

2,5

3,5

4,5

Q
HP

16,6 25 33,3 41,6 50 58,3 66,6 75

MXSU 203/A

2,4

1,4

MXSUM 203/A

3,5

20

450

0,8

0,55

0,75

33

16

12

MXSU 204/A

2,7

1,6

MXSUM 204/A

4,1

20

450

0,85

0,55

0,75

44 41,5 39,5 36,5 33,5 29,5 25,5 21

16

MXSU 205/A

3,3

1,9

MXSUM 205/A

20

450

1,1

0,75

53 49,5 47

44

40

35

30

19

MXSU 206/A

3,8

2,2

MXSUM 206/A

25

450

1,3

0,9

1,2

65

61

58

54

49

43

37 30,5 23

Capacitor

P1

m3/h

2,5

3,5

4,5

kW

kW

HP

l/min

41,6 50 58,3 66,6 75 83,3 100 116 133

3~

230 V 400 V

230 V

1~

P2

MXSU 404/A

3,8

2,2

MXSUM 404/A

25

450

1,3

0,9

1,2

MXSU 405/A

4,5

2,6

MXSUM 405/A

25

450

1,55

1,1

1,5

230 V 400 V

230 V

1~

Capacitor

P1

22

19

25

3~

Hm

31 29,5 27,5 25

43

39

53

48 46,5 45 42,5 40 37,5 31

m 3/h

l/min

Hm

P2

38 36,5 34,5 33 30,5 25,5 19,5 13

10

24

15

11

Q
A

MXSU 803/A

4,5

2,6

MXSU 804/A

6,6

3,8

MXSUM 803/A

P1 Max. power input.


P2 Rated motor power output.

kW

kW

HP

25

450

1,55

1,1

1,5

1,5

Hm

83,3 100 116 133 150 166 183

34,5 29,5 28 26,5 24,5 22,5 20 16,5


45,5 39 37 35 32,5 30 26,5 22,5

Test results with clean cold water, without gas content.


Tolerances according to UNI EN ISO 9906:2012

Dimensions and weights


G1 1/4
ISO 228

13

fM

MXSUM 203/A

524

12,3

11,5

MXSUM 204/A

524

12,5

12

MXSUM 205/A

548

13,6

MXSU 203/A

524

11,3

MXSU 204/A

524

MXSU 205/A

548

MXSU 206/A

572

13,3

MXSUM 206/A

572

14,8

MXSU 404/A

524

12,4

MXSUM 404/A

524

14

MXSU 405/A

548

12,9

MXSUM 405/A

548

14,4

MXSU 803/A

548

12,5

MXSUM 803/A

548

14,1

MXSU 804/A

548

14,7

32

kg

kg

72

mm

mm

fM

PUMP
Pompa

ISO 228

fM

G 1 1/4

PUMP
Pompa

4.93.179

90
45

60

149

118

9
165
190

MXSU

Vertical multi-stage close coupled pumps

Characteristic curves n 2900 rpm


0

Imp g.p.m.

10

15

Imp g.p.m.

10

20

60

70

m
60

MXSU 206/A

50

MXSU 205/A

ft

200

50

MXSU 405/A

ft
40

150

MXSU 404/A

MXSU 204/A

40

100

30

MXSU 203/A

30

150

100
20

20

50

50
10

m3/h 1
0
Q
0
20
l/min

40

10

60

80

40

50

30

40

10

4
0 Q m3 /h

0 Imp g.p.m. 10

72.980.1

20

30

40

50

150

m
40

ft

MXSU 804/A
30

100

MXSU 803/A

20
50
10

m3 /h
0
Q
0
l/min

4
50

6
100

10

12
200

150

60

%
50

16

NPSH
m
3

ft
10

4
0

Q m3/h

10

72.930

4
50

6
100

16

NPSH
m
3

ft

16

NPSH
m
3

m3 /h
0
Q
0
l/min

12

119

ft
10

4
0

Q m3 /h

72.981

MXSU

Vertical multi-stage close coupled pumps

Features

3.94.053

Control box for single-phase pumps (on request)


Pump

Control box

75

Capacitor

M20x1,5

MXSUM 203/A
QM 11

20 F

450 V

QM 12

25 F

450 V

200

MXSUM 205/A
MXSUM 206/A
MXSUM 404/A
MXSUM 405/A
MXSUM 803/A

4.93.119

MXSUM 204/A

M20x1,5

120

76

kg 0,4

09/2016

MXV-B

Vertical Multi-Stage Close Coupled Pumps


Construction
Vertical multi-stage close coupled pumps with suction and delivery connections of the same diameter and arranged along the
same axis (in-line).
All parts that come into contact with the liquid, including wet-end
covers, are in chrome-nickel stainless steel with corrosionresistant bearing sleeves lubricated by the pumped liquid.

Version with frequency converter (on request)

Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter and non-aggressive for stainless steel (with
adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-boosting systems, fire-extinguishing systems, high-pressure
washing plants, irrigation, agricultural uses and sport installations.

Operating conditions
Temperature of liquid: from -15 C to +90 C.
Operating environment temperature: up to 40 C.
Maximum permissible pressure in pump casing: 16 bar.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
MXV-B: three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% from 3,7 to 7,5 kW.
MXV-BM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F. Protection IP 54.
Motor suitable for operation with frequency converter from 2,2 kW.
Classification scheme IE2 for three-phase motors up to 5,5
kW, IE3 for 7,5 kW.
Constructed in accordance with: EN 60034-1, EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials (wetted parts)


The electropumps MXV-B 25,32,40.. series comply with the European
Regulation no. 547/2012 (MXV-B 50 series cannot be sold in the EU).

Coverage chart n 2900 rpm


5 Imp. g.p.m.

4
5

10

20

U.S. g.p.m. 10

20

30
30

40
40

50

50

100
100

120

Component
External jacket
Suction casing
Delivery casing
Stage casing
Impeller
Lower cover
Upper cover
Spacer sleeve

Material

Chrome-nickel steel
1.4301 EN 10088 (AISI 304)

Pump shaft
Plug

Chrome-nickel steel
1.4305 EN 10088 (AISI 303)

Mechanical seal
ISO 3069 - KU

Ceramic alumina/Carbon/EPDM

Wear ring

PTFE

O-ring

NBR

MXV-B
100
300

200

50

32-4..

25-2..

40-8..

Special features on request

50-18..

40

ft
100

30

- Other voltages. - Frequency 60 Hz.


- Protection IP 55. - Special mechanical seal
- Pump casing seal rings in FPM.
- Higher or lower liquid or ambient temperatures.
- Flanges to screw, in chrome-nickel steel.
- Motor suitable for operation with frequency converter up to 1,5 kW.

Designation
20

15

2
m3/h
Q
20 l/min 30

40

3
50

5
100

10
150
200

50
20
30
300
400 500
72.1002/1

121

Series
Single-phase motor (up to 2.2 kW)
With frequency converter I-MAT
DN ports in mm
Rated capacity in m3/h
Number of stages

MXV-B M E I 2 5 - 2 0 5

10

MXV

Vertical Multi-Stage In-Line Pumps

Pumps with frequency converter


The MXV-B EI pumps are available with power from 0,75 kW up to 7,5 kW,
the pumps are equipped with I-MAT installed on board which allows to
realize a variable-speed system extremely compact and efficient, ideal in
applications of water supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is
already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,75 kW to 7,5 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed connection ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases

Operating modes
H

Constant pressure mode


with pressure transducer

+
-

In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H

Proportional pressure mode


with pressure transducer

+
-

In this mode the system changes the working pressure according to the required
flow rate.

Constant flow mode


with flow meter
In this mode the system maintains a constant flow rate value in a point of the installation according to the required pressure.

Fixed speed mode


with setting of the speed preferential rotation.
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range.

H
max

+
min

Constant temperature mode


with temperature transducer
In this mode the system keeps the temperature constant inside a system by changing the speed of the pump.
122

MXV-B

25-2

Vertical Multi-Stage Close Coupled Pumps

Characteristic curves and performance n 2900 rpm


0

U.S. g.p.m.

10

15

20

120

MXV-B 25-210

100
300

8
80

7
m

10

ft

H
6

200

60

5
4
40

100

20

0
0
0

m3/h
l/min

2
20

30

40

3
50

60

70

80
0.2

50

Pst
Pst

40

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

0.1

kW

30
4

ft

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.


P1 Max. power input.
P2 Rated motor power output.

10

NPSH
2
m
0
0

m3/h

3~

230 V 400 V

1~

72.1130

230 V P1

P2

m3/h
Q
l/min

1,5

16,6

25

kW

kW

HP

MXV-BM 25-203

5,8

1,1

0,75

34

32

30

1,9

MXV-BM 25-204

5,8

1,1

0,75

44

42,5

40

1,9

MXV-BM 25-205

5,8

1,1

0,75

56

53

50

2,7

MXV-BM 25-206

7,4

1,5

1,1

1,5

68

MXV-B 25-203

3,3

1,9

MXV-B 25-204

3,3

MXV-B 25-205

3,3

MXV-B 25-206

4,7

63,5 60,5

2,5

3,5

33,3 41,6

50

58,3 66,6

28

26

37,5 34,5
47
56

43

23,5 20,5

75

17

12,5

27

22,5

17

39

34

28

21

34

25

MXV-B 25-207

4,7

2,7

MXV-BM 25-207

7,4

1,6

1,1

1,5

79,5

74

70,5 65,5

MXV-B 25-208

7,5

4,3

MXV-BM 25-208

9,2

1,5

91

85

80,5

75

69

62

MXV-B 25-210

7,5

4,3

MXV-BM 25-210

9,2

2,3

1,5

114

106

101

94

86

78

123

4,5

31

51,5 46,5 40,5


60

54,5 47,5 39,5

30

54

45,5

34

68

57

42

MXV-B

32-4

Vertical Multi-Stage Close Coupled Pumps

Characteristic curves and performance n 2900 rpm


0

10

U.S. g.p.m.

20

30

120

MXV-B 32-410

100

300

80

ft

60

200

5
4

40

100

20

0
0

m /h
Q l/min

3
50

55

6
100

9 0
150
0.25

0.2

Pst

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

Pst
kW

45
%

0.1
0.05

35
4

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

10

NPSH

ft

Pst = Power with reference to one stage.


P1 Max. power input.
P2 Rated motor power output.

m
0
0

m3/h

3~

230 V 400 V

1~

230 V P1

P2

72.1131

m3/h
Q
HP l/min

0
9

2,5

3,5

41,6

50

58,3 66,6

kW

kW

MXV-BM 32-403

5,8

1,1

0,75

34

31

30,5

2,7

MXV-BM 32-404

7,4

1,5

1,1

1,5

45

41,5

40

4,7

2,7

MXV-BM 32-405

7,4

1,6

1,1

1,5

56

51,5

50

48

7,5

4,3

MXV-BM 32-406

9,2

1,5

68

62

60

58

7,5

4,3

MXV-BM 32-407

9,2

2,3

1,5

MXV-B 32-408/A 9,15 5,3

2,2

91

83

MXV-B 32-410/A 9,15 5,3

2,2

114

104 101 97,5

MXV-B 32-403

3,3

1,9

MXV-B 32-404

4,7

MXV-B 32-405
MXV-B 32-406
MXV-B 32-407

124

H
m

79,5 72,5 70,5


80,5

29

28

4,5
75
26,5

43,5

83,3 100 116,6 133,3


25

21

38,5 36,5 34,5 32,5 27,5


46

41

55,5 52,5 49,5

17

11,5

22

14,5

34,5 27,5 18,5


42

33,5 22,5

68

65

61,5

58

49

39

26,5

78

74

70

66

56

44,5

30

93

88

83

70

56

38

MXV-B

40-8

Vertical Multi-Stage Close Coupled Pumps

Characteristic curves and performance n 2900 rpm


0 U.S. g.p.m. 10

20

30

40

60

50

120

MXV-B 40-810

100
300

8
80

ft

10

H
m

6
200

60

5
4
40

3
100

20

0
0
0

m3/h 2
l/min

4
50

6
100

10

14

12
200

150

70

0.4

Pst

Pst

60

0.2

kW

50
4

NPSH

10

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

ft

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.


P1 Max. power input.
P2 Rated motor power output.

m
0
0

m3/h 2

3~

230 V 400 V
A

4,7

2,7

MXV-B 40-804

7,5

4,3

MXV-B 40-805/A

9,15 5,3

MXV-B 40-803

MXV-B 40-806/A

9,15 5,3

MXV-B 40-807/A

11,5

MXV-B 40-808/A

11,5

MXV-B 40-810/A

10

72.1132

12

14

kW

kW

m 3/h
Q
HP l/min

MXV-BM 40-803

7,4

1,6

1,1

1,5

MXV-BM 40-804

9,2

2,3

1,5

47

43

2,2

59

54

71

1~

230 V P1

P2

0
0

10

11

12

13

83,3 100 116,6 133,3 150 166,6 183,3 200 216,6


31

29,5

28

42

41

40

37

34

30

26

21

53

51

50

47

43

38

32

26

65

63

62

59

56

51

45

39

31

35,5 32,5 31,5

H
m

25,5 22,5 19,5 15,5

2,2

6,6

83

76

74

72

69

66

60

53

45

36

6,6

95

87

85

82

79

75

69

60

51

42

9,6

3,7

119

109 106

103

99

94

86

75

64

52

125

MXV-B

50-18

Vertical Multi-Stage Close Coupled Pumps

Characteristic curves and performance n 2900 rpm


0 U.S. g.p.m. 20

40

60

80

120

100

140

400

MXV-B 50-1810

120

H
m
100

9
300

8
80

ft

7
6
200

60

5
4
40

3
100
20

0
0
0

m3/h 4
l/min

12
200

100

16

20

28

24
400

300

100

0.8
Pst

Pst

60

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

0.4

kW

20
8

NPSH

20

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

ft

Pst = Power with reference to one stage.


P1 Max. power input.
P2 Rated motor power output.

m
0

0
0

m3/h 4

3~

12

16

20

24

230 V 400 V

P2

72.1132

m 3/h
Q
HP l/min

kW

MXV-B 50-1803/A

9,15

5,3

2,2

MXV-B 50-1804/A

11,5

28

0
0

14

16

18

20

22

25

83,3 133,3 183,3 233

266

300

333

366

416

35,5 33,5

32

11

30

27,5 25,5 23,5 20,5 16,5

6,6

48

46,5 44,5 41,5

38

36

33

MXV-B 50-1805/A

9,6

3,7

60

57,5

55

51,5

48

45

42

MXV-B 50-1806/A

9,6

5,5

71

68

65

61

56

53

49

44

36

22

MXV-B 50-1807/A

10,9

5,5

7,5

84

81,5

78

73,5

68

64,5

60

54

45

28

MXV-B 50-1808/A

10,9

5,5

7,5

94,5

92

88

82

76

72

68

60

50

32

MXV-B 50-1809/A

14,3

7,5

10

108

105

100

95

89

84

79

71

60

40

MXV-B 50-1810/A

14,3

7,5

10

120

117

112

106

98

94

88

78

67

44

126

H
m

29

23

37,5 31,5

14
19

MXV-B

Vertical Multi-Stage Close Coupled Pumps

Dimensions and weights


AD

Pump
Pompa

h1

(1)

(25 MXV-B 40-8..)


20 (25 MXV-B 50-18..)

fM

(3)

4.93.298

(2)

n1

n2

s
m2
m1

(1)(1)
Filling
Riempimento
Scarico
(2)(2)
Draining
Posizione
standard
scatola morsetti
(3)(3)
Standard
position
of terminal
box
posizioni
ruotando
motorethrough
di 90 o90
180)
(for(altre
other
positions
rotateilmotor
or 180)

fM
h1

20 (25 MXV-B EI 40-8..)

(1) (4)

4.93.298

AG
AS

n1

n2

(2)

s
m2
m1

(1) Filling
(2) Draining
(3) Standard position of I-MAT
(for other positions rotate motor through 90 or 180)
(4) Pressure transducer

G1
G1
G1
G1
G1
G1
G1

h1
75
75
75
75
75
75
75

fM
564
565
588
612
636
660
708

AD
128
128
128
128
128
128
128

n1
210
210
210
210
210
210
210

n2
180
180
180
180
180
180
180

m1
150
150
150
150
150
150
150

m2
100
100
100
100
100
100
100

s
12,5
12,5
12,5
12,5
12,5
12,5
12,5

1
1,5
1,5
2
2
3
3
1,5
2
3
3
4
4
5

G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2

215
215
215
215
215
215
215
225
225
225
225
225
225
225

75
75
75
75
75
75
75
80
80
80
80
80
80
80

564
565
588
612
636
700
748
593
593
663
693
746
776
953

128
128
128
128
128
128
128
128
128
128
128
138
138
138

210
210
210
210
210
210
210
246
246
246
246
246
246
246

180
180
180
180
180
180
180
215
215
215
215
215
215
215

150
150
150
150
150
150
150
190
190
190
190
190
190
190

100
100
100
100
100
100
100
130
130
130
130
130
130
130

12,5
12,5
12,5
12,5
12,5
12,5
12,5
14
14
14
14
14
14
14

24
25
26
28
29
34
35
27
28
33
34
45
49
49

25
26
27
29
30
28
29
-

3
4
5
5,5
7,5
7,5
10
10

G2
G2
G2
G2
G2
G2
G2
G2

250
250
250
250
250
250
250
250

90
90
90
90
90
90
90
90

635
701
738
776
841
878
916
953

128
138
138
138
160
160
160
160

246
246
246
246
246
246
246
246

215
215
215
215
215
215
215
215

190
190
190
190
190
190
190
190

130
130
130
130
130
130
130
130

14
14
14
14
14
14
14
14

34
44
46,5
47,5
59
60
67
68

ISO 228

MXV-B(M) 25-203
MXV-B(M) 25-204
MXV-B(M) 25-205
MXV-B(M) 25-206
MXV-B(M) 25-207
MXV-B(M) 25-208
MXV-B(M) 25-210
MXV-B(M) 32-403
MXV-B(M) 32-404
MXV-B(M) 32-405
MXV-B(M) 32-406
MXV-B(M) 32-407
MXV-B
32-408/A
MXV-B
32-410/A
MXV-B(M) 40-803
MXV-B(M) 40-804
MXV-B
40-805/A
MXV-B
40-806/A
MXV-B
40-807/A
MXV-B
40-808/A
MXV-B
40-810/A

0,75
1,1
1,1
1,5
1,5
2,2
2,2
1,1
1,5
2,2
2,2
3
3
3,7

MXV-B
MXV-B
MXV-B
MXV-B
MXV-B
MXV-B
MXV-B
MXV-B

2,2
3
3,7
4
5,5
5,5
7,5
7,5

Pump
Pompa

MXV-B MXV-BM
kg
kg
24
23
24,5
23,5
25,5
24,5
27
26
28
27
31
30
32
31

a
215
215
215
215
215
215
215

HP
1
1
1
1,5
1,5
2
2

AD

(3)

kW
0,75
0,75
0,75
1,1
1,1
1,5
1,5

50-1803/A
50-1804/A
50-1805/A
50-1806/A
50-1807/A
50-1808/A
50-1809/A
50-1810/A

Net
Pesoweight
netto

mm

Motor
Motore
P2
P2

Motor
Motore
P2
P2

Net
weight

mm
G

kW
0,75
0,75
0,75
1,1
1,1
1,5
1,5

HP
1
1
1
1,5
1,5
2
2

ISO 228

MXV-B EI 25-203
MXV-B EI 25-204
MXV-B EI 25-205
MXV-B EI 25-206
MXV-B EI 25-207
MXV-B EI 25-208
MXV-B EI 25-210

G1
G1
G1
G1
G1
G1
G1

a
215
215
215
215
215
215
215

h1
75
75
75
75
75
75
75

fM
564
565
588
612
636
660
708

AD
286
286
286
286
286
286
286

AG
190
190
190
190
190
190
190

AS
105
105
105
105
105
105
105

n1
210
210
210
210
210
210
210

n2
180
180
180
180
180
180
180

m1
150
150
150
150
150
150
150

m2
100
100
100
100
100
100
100

s
12,5
12,5
12,5
12,5
12,5
12,5
12,5

kg
29,4
29,9
30,9
32,4
33,4
36,4
37,4

MXV-B EI 32-403
MXV-B EI 32-404
MXV-B EI 32-405
MXV-B EI 32-406
MXV-B EI 32-407
MXV-B EI 32-408
MXV-B EI 32-410
MXV-B EI 40-803
MXV-B EI 40-804
MXV-B EI 40-805
MXV-B EI 40-806
MXV-B EI 40-807
MXV-B EI 40-808
MXV-B EI 40-810

0,75
1,1
1,1
1,5
1,5
2,2
2,2
1,1
1,5
2,2
2,2
3
3
3,7

1
1,5
1,5
2
2
3
3
1,5
2
3
3
4
4
5

G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2

215
215
215
215
215
215
215
225
225
225
225
225
225
225

75
75
75
75
75
75
75
80
80
80
80
80
80
80

564
565
588
612
636
700
748
593
593
663
693
746
776
953

286
286
286
286
286
286
286
286
286
286
286
294
294
294

190
190
190
190
190
210
210
190
190
190
190
210
210
210

105
105
105
105
105
118
118
105
105
105
105
118
118
118

210
210
210
210
210
210
210
246
246
246
246
246
246
246

180
180
180
180
180
180
180
215
215
215
215
215
215
215

150
150
150
150
150
150
150
190
190
190
190
190
190
190

100
100
100
100
100
100
100
130
130
130
130
130
130
130

12,5
12,5
12,5
12,5
12,5
12,5
12,5
14
14
14
14
14
14
14

30,4
31,4
32,4
34,4
35,4
41,5
42,5
33,4
34,4
40,5
41,5
52,5
56,5
56,5

MXV-B EI 50-1803
MXV-B EI 50-1804
MXV-B EI 50-1805
MXV-B EI 50-1806
MXV-B EI 50-1807
MXV-B EI 50-1808
MXV-B EI 50-1809
MXV-B EI 50-1810

2,2
3
3,7
4
5,5
5,5
7,5
7,5

3
4
5
5,5
7,5
7,5
10
10

G2
G2
G2
G2
G2
G2
G2
G2

250
250
250
250
250
250
250
250

90
90
90
90
90
90
90
90

635
701
738
776
841
878
916
953

286
294
294
294
368
368
368
368

210
210
210
210
281
281
281
281

118
118
118
118
153
153
153
153

246
246
246
246
246
246
246
246

215
215
215
215
215
215
215
215

190
190
190
190
190
190
190
190

130
130
130
130
130
130
130
130

14
14
14
14
14
14
14
14

41,5
51,5
54,0
55,0
73,8
74,8
81,8
82,8

127

10

MXV-B

Vertical Multi-Stage Close Coupled Pumps

Features

3.93.127

Wider Range of Application


All parts that come into contact with the liquid, including wet-end covers, are in chromenickel stainless steel.
With corrosion-resistant seal rings and guide ring.

Low Cost Installation


Vertical construction with reduced pump height for installation in small spaces.
In-line connections to simplify the piping layout with the possibility of inserting the pump in straight
pipe-lines.
Disassembly, inspection or cleaning of internal parts without removal of piping.

Robust and Reliable


The suction and discharge nozzles arranged in-line absorb the forces of the piping on the
pump without the creation of distorting loads causing local friction and early wears.
The lantern brackets compact and robust design maintains a sure alignment between
rotating and fixed parts, reducing vibration.
The upper cover design prevents entrapment of air around the mechanical seal.

Low-Noise Operation
The water filled shroud around the stages and thick external walls, work together for lownoise operation.

128

09/2016

MXV

Vertical Multi-Stage In-Line Pumps


Construction
Vertical multi-stage pumps with suction and delivery connections
of the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped liquid.
A pump with thrust bearing and sleeve coupling for use of any
standard motor with IM V1 construction.

Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-boosting
systems, fire-extinguishing systems, high-pressure washing
plants, irrigation, agricultural uses and sport installations.

Operating conditions
Temperature of liquid: from -15 C to +110 C.
Operating environment temperature: up to 40 C.
Maximum permissible pressure in pump casing: 25 bar.

Motor
Standard-type: 2-4 pole induction motor, 50 Hz.
Construction IM V1 (EN 60034-7).
Motor suitable for operation with frequency converter.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from 7,5 kW.
Insulation class F.
Protection IP 55.
three-phase with rated voltage: up to 3 kW 230/400 V;
from 4 kW 400/690 V.
The electropumps MXV series comply with the European Regulation no.
547/2012.

MXV 25, 32, 40

Rated speed of rotation (50 Hz):

MXV 2900 rpm


MXV4 1450 rpm.

MXV 50, 65, 80, 100

All parts that come into contact with the liquid, including wet-end
covers, are in chrome-nickel stainless steel AISI 304.

Internal parts in contact with the liquid in chrome-nickel stainless steel,


AISI 304 with pump casing and upper cover in cast iron.

Materials (wetted parts)

Materials (wetted parts)

Component
Flange
External jacket
Suction casing
Delivery casing
Stage casing
Impeller
Lower cover
Upper cover
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing
Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

Component

Material

Pump casing
Upper cover
External jacket
Stage casing
Impeller
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing

Cast iron GJL 250 EN 1561

Material

Stainless Steel
1.4301 EN 10088 (AISI 304)

Stainless Steel
1.4305 EN 10088 (AISI 303)
Corrosion-resistant, cemented carbide
Ceramic alumina

Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

Hard metal/Carbon/EPDM.

PTFE
NBR

Stainless Steel 1.4301 EN 10088 (AISI 304)


Stainless Steel (AISI 303)(AISI 431 for MXV 100)
Stainless Steel (AISI 303)(AISI 304 for MXV 100)
Corrosion-resistant, cemented carbide
Ceramic alumina
(Corrosion-resistant, cemented carbide for MXV 100)
Hard metal/Carbon/EPDM

PTFE
NBR (EPDM for MXV 100)

Direction of rotation: anticlockwise as seen from the motor.

Direction of rotation: clockwise as seen from the motor.

(clockwise as seen from the motor for MXV 100)

Variants (to be specified when ordering)

Variants (to be specified when ordering)

Pump with threaded ports (G).


Pump with flanged ports (F).
Pump without motor.
Pump with standard motor.

Pump without motor.


Pump with standard motor.

Other variants (on request)

Other variants (on request)

O-rings FPM. Other mechanical seal.


Pump with motor of Client's choice (if available).
Other voltage ratings.
Frequency 60 Hz.
Pump with support feet for horizontal installation (H1 or H2).
Support feet for horizontal installation, set.
Welding counter-flanges, PN 25 (steel).

With counter-flanges in chrome-nickel steel.


O-rings FPM. Other mechanical seal.
Pump with motor of Client's choice (if available).
Single-phase motor 230 V, up to 2.2 kW.
Other voltage ratings.
Frequency 60 Hz.

129

11

MXV

Vertical Multi-Stage In-Line Pumps

Pumps with frequency converter


The MXV EI pumps are available with power from 0,25 kW up to 11 kW,
the pumps are equipped with I-MAT installed on board which allows to
realize a variable-speed system extremely compact and efficient, ideal in
applications of water supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is
already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,25 kW to 11 kW
Control range from 1750 to 2900 rpm (2-pole)
Control range from 870 to 1450 rpm (4-pole)
Protection against dry running
Protection against operations with closed connection ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases

Operating modes
H

Mode at a constant pressure


with pressure sensor

+
-

In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H

Proportional pressure mode


with pressure sensor

+
-

In this mode the system changes the working pressure according to the required
flow rate.

Constant flow mode


with flow meter
In this mode the system maintains a constant flow rate value in a point of the
installation according to the required pressure.

Q
H

Fixed speed mode


with setting of the speed preferential rotation.

max

In this mode, by changing the working frequency, you may choose any operational
curve included within the working range.

+
min

Constant temperature mode


with temperature transducer
In this mode the system keeps the temperature constant inside a system by
changing the speed of the pump.
130

MXV

Vertical Multi-Stage In-Line Pumps

MXV 25, 32, 40

MXV 50, 65, 80, 100

Designation

Designation
MXV 4 EI 25-205

G *

MXV 4 EI 50-1605

Series
4 pole (no code = 2 pole)
With frequency converter I-MAT
DN ports in mm
Rated capacity in m3/h (n 2900 rpm)
Number of stages

Series
4 pole (no code = 2 pole)
With frequency converter I-MAT
DN ports in mm
Rated capacity in m3/h (n 2900 rpm)
Number of stages

Construction variants
special seal code (no code = standard seal)
threaded ports
flanged ports
with motor (or without motor)
* with no further designation = with standard motor

Construction variants
special seal code (no code = standard seal)
with support feet for horizontal installation H, variant 1
with motor (or without motor)
* with no further designation = with standard motor

G
F

H1 *

11

Installations

Pipe connection

Vertical installation
(Standard).

4.93.213/1

4.93.213/2

4.93.213/3

4.93.213/4

3.93.013

Pump with threaded ports:


pipes screwed into the ports

Pump with threaded ports:


pipes with union couplings
(locally available)

Horizontal installation.

Pump with flanged ports:


pipes with counter-flanges

Pump size

Number
of stages

Stage casings
with bearing

40 - 804
40 - 805
40 - 806
40 - 807
40 - 808
40 - 810

4
5
6
7
8
10

1
1
1
1
1
1

40 - 811

11
12
13
14
15
16
18

2
2
2
2
2
2
2

17
19
20

3
3
3

MXV - MXV4
32 - 404
32 - 405
32 - 406
32 - 407
32 - 408
32 - 410

25 - 212

32 - 412

25 - 214

32 - 414

40 - 813
40 - 815
25 - 216
25 - 218

32 - 416
32 - 418
40 - 817
40 - 819

25 - 220

Variant H2:
suction on the right,
delivery on the left.

Variable parts

Variable parts

25 - 204
25 - 205
25 - 206
25 - 207
25 - 208
25 - 210

Variant H1:
suction on the left,
delivery on the right.

Pump size

Number
of stages

Stage casings
with bearing

80 - 4801
80 - 4802
80 - 4803
80 - 4804
80 - 4805

1
2
3
4
5
6
7
8
9
10

1
1
1
1
1
1
1
1
1
1

80 - 4806
80 - 4807
80 - 4808

6
7
8
9
10
11
12
14
16

2
2
2
2
2
2
2
2
2

MXV - MXV4

50 - 1603
50 - 1604
50 - 1605
50 - 1606
50 - 1607
50 - 1608
50 - 1609
50 - 1610

65 - 3202
65 - 3203
65 - 3204
65 - 3205
65 - 3206
65 - 3207

65 - 3208
65 - 3209
65 - 3210
50 - 1611
50 - 1612
50 - 1614
50 - 1616

131

65 - 3212

MXV

Vertical Multi-Stage In-Line Pumps

Coverage chart
4

Imp. g.p.m.

10

20

30

40

50

100

200

300

400

500

250
800

MXV
n 2900 1/min

700
200

ft

500

150

25-2

40-8

32-4

65-32

50-16

400

100-65
100

300

100-90

80-48

200

50
100

m3 /h
l/min

2
30

3
40

50

9 10
150

100

16
200

20

32

300

400

40

48

500

60

0
150

70 80 90100

1000

1500

2000
72.936/1

Imp. g.p.m.

10

20

30

40

50

100

64
200

MXV4

60

n 1450 1/min

180

50

160

140

50-16

40

ft

100

30

25-2

65-32

40-8

32-4

80
20
60

80-48
40
10
20

0
0,6
10

0,8

1
20

m 3/h
l/min

30

3
40

50

6
100

9 10
150

16
200

20
300

30
400

40

500
72.1036

132

MXV 25-2

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0

U.S. g.p.m.

10

15

20

240

MXV 25-220

220

700
200

18
600

180

16

ft

H
m

14

500

11

140

12
400

120

10
100
300

8
80

7
6

60

200

5
4

40
100
20

0
0

m3/h
l/min

2
20

30

40

3
50

4
60

5
70

80
0.2

50

Pst
Pst

40

0.1

kW

30
4

10

NPSH

ft

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids with
density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

m
0
0

m3/h

72.983

Motor power

Pump type

230 V
A*

A*

kW

HP

MXV 25-204/C
MXV 25-205/C
MXV 25-206/C
MXV 25-207/C
MXV 25-208/C

3,3
3,3
4,7
4,7
7,4
7,4
9,2
9,2
11,4
11,4
11,4

1,9
1,9
2,7
2,7
4,3
4,3
5,3
5,3
6,6
6,6
6,6

0,75
0,75
1,1
1,1
1,5
1,5
2,2
2,2
3
3
3

1
1
1,5
1,5
2

MXV 25-210/C
MXV 25-212/C
MXV 25-214/C
MXV 25-216/C
MXV 25-218/C
MXV 25-220/C

400 V

2
3
3
4
4
4

m3/h
l/min

H
m

Pst = Power with reference to one stage.


A* Calpeda motor currents

0
5

1,5

16,6

25

33,3

44
56
68
79,5
91
114
136
159
182
205
228

42,5
53
63,5
74
85
106
127
149
170
191
213

40
50
60,5
70,5
80,5
101
121
141
161
181
202

37,5
47
56
65,5
75
94
112
131
150
169
188

133

3,5

41,6

50

58,3

66,6

75

34,5
43
51,5
60
69
86
103
121
138
155
173

31
39
46,5
54,5
62
78
93,5
109
124
140
156

27
34
40,5
47,5
54
68
81,5
95
108
122
136

22,5
28
34
39,5
45,5
57
68
79,5
91
102
114

17
21
25
30
34
42
51
59
68
76
85

2,5

4,5

MXV 32-4

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0

10

Imp. g.p.m.

20

30

240

220
700
200

MXV 32-418
600

180

ft

16

500

14

140

12

120

400

10

100

300

8
7
6
5
4

80

60

40

200

100
20

0
0

m /h
Q l/min

3
50

55

6
100

9
150

0.25

0.2

Pst

Pst
kW

45
%

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

0.1
0.05

35
4

10

NPSH

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

ft

2
m
0
0

m3/h

Pump type
MXV 32-404/C
MXV 32-405/C
MXV 32-406/C
MXV 32-407/C
MXV 32-408/C
MXV 32-410/C
MXV 32-412/C
MXV 32-414/C
MXV 32-416/C
MXV 32-418/C

230 V

400 V

Motor power

A*

A*

kW

4,7
4,7
7,4
7,4
9,2
9,2
11,4
11,4

2,7
2,7
4,3
4,3
5,3
5,3
6,6
6,6
9,6
9,6

1,1
1,1
1,5
1,5
2,2
2,2
3
3
4
4

HP
1,5
1,5
2
2
3
3
4
4
5,5
5,5

m3/h
l/min

H
m

72.984

Pst = Power with reference to one stage.


A* Calpeda motor currents

0
9

2,5

3,5

41,6

50

58,3

45
56
68
79,5
91
114
136
159
182
205

41,5
51,5
62
72,5
83
104
124
145
166
187

40
50
60
70,5
80,5
101
121
141
161
181

38,5
48
58
68
78
97,5
117
136
156
175

134

83,3

100

116,6

133,3

32,5
41
49,5
58
66
83
99,5
116
132
149

27,5
34,5
42
49
56
70
84
98
112
126

22
27,5
33,5
39
44,5
56
67
78
89,5
100

14,5
18,5
22,5
26,5
30
38
45,5
53
60,5
68

4,5

66,6

75

36,5
46
55,5
65
74
93
111
130
148
167

34,5
43,5
52,5
61,5
70
88
105
123
140
158

MXV 40-8

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0 Imp. g.p.m.

10

20

30

40

50

240

220

MXV 40-819

700

200

17

600

180

ft

15

500

13

140

11

11

120

400

10
100
300

8
80

7
6

60

200

4
40
100
20

0
0

m3/h 2
l/min

6
100

50

10

14

12
200

150

70

0.4

Pst

Pst

60

0.2

kW

50
4

NPSH

10

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids with
density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

ft

2
m
0

Pst = Power with reference to one stage.


A* Calpeda motor currents

0
0

m3/h 2

Pump type
MXV 40-804/C
MXV 40-805/C
MXV 40-806/C
MXV 40-807/C
MXV 40-808/C
MXV 40-810/C
MXV 40-811/C
MXV 40-813/C
MXV 40-815/C
MXV 40-817/C
MXV 40-819/C

230 V

400 V

10

Motor power

A*

A*

kW

HP

7,4
9,2
9,2
11,4
11,4

4,3
5,3
5,3
6,6
6,6
9,6
9,6
10,9
10,9
14,3
14,3

1,5
2,2
2,2
3
3
4
4
5,5
5,5
7,5
7,5

2
3
3
4
4
5,5
5,5
7,5
7,5
10
10

m3/h
l/min

H
m

12

72.392

14

83,3

100

116,6

133,3

150

47
59
71
83
95
119
131
155
179
202
226

43
54
65
76
87
109
119
141
163
184
206

42
53
63
74
85
106
116
138
159
180
201

41
51
62
72
82
103
113
134
154
175
195

40
50
59
69
79
99
109
129
149
168

37
47
56
66
75
94
103
122
141
159
178

135

188

10

11

166,6 183,3
34
43
51
60
69
86
94
111
128
145
162

30
38
45
53
60
75
83
98
113
128
143

12

13

200

216,6

26
32
39
45
51
64
71
84
96
109
122

21
26
31
36
42
52
57
68
78
89
99

MXV 50-16

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0

25

Imp. g.p.m.

280

50

75

MXV 50-1616

900

260
800

240

14

220
700

12

200
180

H
m
140

11

600

10

ft

500

120

100

400

300

80

4
200

60

3
40
100
20
0

0
0

m3/h
l/min

10
100

150

15
200

250

300

25

20
350

400

80

1.0
Pst

Pst

60

0.6

kW

40
8

0.2

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

20

NPSH

10

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.


A* Calpeda motor currents

ft

4
m
0
0

m /h

10

Motor power

Pump type

230 V
A*

A*

kW

HP

MXV 50-1603/C
MXV 50-1604/C
MXV 50-1605/C
MXV 50-1606/C
MXV 50-1607/C
MXV 50-1608/C

11,4

6,6
9,6
10,9
10,9
14,3
14,3
21,5
21,5
21,5
27,3
27,3
34

3
4
5,5
5,5
7,5
7,5
11
11
11
15
15
18,5

4
5,5
7,5
7,5
10

MXV 50-1609/D
MXV 50-1610/D
MXV 50-1611/D
MXV 50-1612/D
MXV 50-1614/D
MXV 50-1616/D

400 V

15

10
15
15
15
20
20
25

72.937

20

m3/h

l/min

H
m

25

10

12

14

16

18

20

22

24

133,3

166,6

200

233

266

300

333

366

400

51
69
86
103
120
138
155
172
189
206
240
275

49
65
81
98
114
130
147
163
179
196
228

48
63
79
95
111
127
143
159
175
190
222

46
61
76
92
107
122
138
153
168
184
214
245

44
59
73
88
103
117
132
147
161
176
206
235

41
55
69
83
97
110
124
138
152
166
193
221

38
51
63
76
89
101
114
127
139
152
178
203

33
44
55
67
78
89
100
111
122
133
156
178

27
37
46
55
64
73
83
92
101
110
129
147

20
27
33
40
47
53
60
67
73
80
94
107

136

MXV 65-32

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0

50

Imp. g.p.m.

100

150

240

MXV 65-3212

220

700
200
600

180

10
ft

H
m

140

500

11

120

400

6
100

5
80

300

60

200

3
2

40

100
20

0
0

m3/h
l/min

10

20
200

300

400

30
500

50

40
600

700

800

80

2
Pst

Pst

60

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

kW

40
8

NPSH

20

10

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.


A* Calpeda motor currents

ft

4
m
0
0

m /h

Pump type

10

20

230 V
A*

MXV 65-3202/C
MXV 65-3203/C
MXV 65-3204/C
MXV 65-3205/D
MXV 65-3206/D
MXV 65-3207/D
MXV 65-3208/D
MXV 65-3209/D
MXV 65-3210/D
MXV 65-3212/D

400 V

30

Motor power

A*

kW

HP

9,6
10,9
14,3
21,5
21,5
27,3
27,3
34
34
41

4
5,5
7,5
11
11
15
15
18,5
18,5
22

5,5
7,5
10
15
15
20
20
25
25
30

72.974

40

50

m3/h

15

21

24

27

30

33

36

39

44

l/min

250

350

400

450

500

550

600

650

733

37
55,5
75
93,5
112
131
150
168
187
225

34
51
69
86
103
121
138
155
172
207

32
49
65,5
82
98,5
115
131
148
164
197

31
47,5
63,5
79,5
95,5
111
127
143
159
191

30
46
61
77
92
107
123
138
154
185

29
43,5
58,5
73
87
102
116
130
145
174

27
40,5
54,5
68
82
95,5
109
122
136
163

24,5
37
50
62,5
75
87,5
100
112
125
150

22
33,5
45
56,5
67,5
79
90
101
112
135

17
25,5
35
44
52,5
61,5
70
79
87,5
105

H
m

137

MXV 80-48

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0

Imp. g.p.m.

50

100

150

200

200

600

180

160

ft
500

MXV 80-4808

H
m
140

400

120

6
100

300

80

4
60

200

40

20

100

0
0

m3/h 10
l/min 200

20
300

40

30
400

500

600

50

700

60

800

900

1000

80
70

4
Pst
3
kW
2

%
60

Pst
50
40

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

1
ft

6
NPSH

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

ft

4
m

10

2
0

Pst = Power with reference to one stage.


A* Calpeda motor currents

0
0

m /h 10

Pump type

230 V
A*

MXV 80-4801/C
MXV 80-4802/C
MXV 80-4803/C
MXV 80-4804/D
MXV 80-4805/D
MXV 80-4806/D
MXV 80-4807/D
MXV 80-4808/D

30

20

400 V

40

Motor power

A*

kW

HP

9,6
10,9
14,3
21,5
27,3
27,3
34
41

4
5,5
7,5
11
15
15
18,5
22

5,5
7,5
10
15
20
20
25
30

72.1035

50

60

m3/h

21

27

33

39

45

48

51

54

60

l/min

350

450

550

650

750

800

850

900

1000

20
40,5
61
81
101
121
142
162

18
36
54
72
90
108
126
144

17
34,5
51
69
86
103
120
137

16
32,5
48
65
81
97
113
129

15
29,5
44
60
75
90
105
120

13
26,5
40
55
68,5
82
96
109

12
24,5
37
51,5
64,5
77,5
90
103

10,7
22
34
48
60
72
84
96

9,5
20
31
44
55
66
77
88

7
15,5
24,5
35
44
53
61,5
70,5

H
m

138

MXV 100-65

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0

100

Imp. g.p.m.

200

300

240

MXV 100-65

220

700

200

8-2R
600

180

7-2R

140

ft
500

11

6-2R
5
400

120

5-2R
4

100

300

4-2R
80

3
3-2R

60

200

2
40

2-2R
100

1
20

0
0

m3/h
l/min

20

40
400

600

800

60
1000

0
100
1600

80
1200

1400

100

80

6
Pst
4
kW
2

60

Pst

40

Pst R

20
12

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

NPSH
ft

8
m

10

4
0
0

m /h

20

Pump type
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)
MXV(L)

100-6501
100-6502-2R
100-6502
100-6503-2R
100-6503
100-6504-2R
100-6504
100-6505-2R
100-6505
100-6506-2R
100-6506
100-6507-2R
100-6507
100-6508-2R
100-6508

40

400 V

60

Motor power

A*

kW

HP

10,9
14,3
21,5
27,3
34
34
41
53
53
53
65
65
78
78
78

5,5
7,5
11
15
18,5
18,5
22
30
30
30
37
37
45
45
45

7,5
10
15
20
25
25
30
40
40
40
50
50
60
60
60

72.974

80

Pst = Power with reference to one stage.


A* Calpeda motor currents

0
100

m3/h

30

36

42

45

54

60

72

78

85

l/min

500

600

700

750

900

1000

1200

1300

1417

28
39
56,5
67,5
84,5
95,5
113
125
142
153
170
181
199
210
227

25
37,5
51
63,5
76
88,5
102
116
129
141
154
166
180
193
206

24,5
36,5
49,5
62
74
86
100
113
125
137
150
162
175
188
200

24
35,5
48,5
60,5
72,5
84
97,5
110
122
134
147
158
172
184
196

23,5
35
48
59,5
71,5
83
96,5
109
121
133
145
156
169
181
193

22,5
33
46
56,5
69
79
92,5
104
116
127
139
150
163
174
186

22
31
45
54
67
75,5
90,5
101
114
123
136
145
159
168
181

20
25
41
46,5
61,5
66
83
90
105
110
125
130
147
152
167

18,5
22
38,5
42
57,5
60,5
78
83
98,5
102
117
120
138
141
157

16,5
17,5
34,5
35,5
51,5
52
70
72,5
88,5
89,5
105
106
124
125
141

H
m

139

MXV 100-90

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 2900 rpm


0

Imp. g.p.m. 100

200

300

400

200

MXV 100-90

180

600

6
160

ft
500

6-2R

H
m

140

5-2R
400

120

4
4-2R

100

300

3
80

3-2R
60

200

2
2-2R

40

1
1-1R

20

0
0

m3/h 20
l/min 400

40
600

100

80

60
800

1000

1200

100

1400

1600

120
1800

2000

100

10

80

8
Pst
6
kW
4

Pst

60

Pst R

40
20

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

2
ft

12
NPSH

10

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.


A* Calpeda motor currents

ft

8
m
4
0
0

m /h 20

Pump type
MXV(L) 100-9001-1R
MXV(L) 100-9001
MXV(L) 100-9002-2R
MXV(L) 100-9002
MXV(L) 100-9003-2R
MXV(L) 100-9003
MXV(L) 100-9004-2R
MXV(L) 100-9004
MXV(L) 100-9005-2R
MXV(L) 100-9005
MXV(L) 100-9006-2R
MXV(L) 100-9006

60

40

400 V

80

Motor power

A*

kW

HP

10,9
14,3
21,5
27,3
34
41
53
53
65
65
78
78

5,5
7,5
11
15
18,5
22
30
30
37
37
45
45

7,5
10
15
20
25
30
40
40
50
50
60
60

72.1035

100

m3/h

l/min

H
m

120

45

0
22
30,5
44,5
62
75,5
93,5
108
125
139
156
170
188

140

54

60

72

78

85

96

108

118

750

900

1000

1200

1300

1417

1600

1800

1967

21
27,5
43
55,5
70,5
84
100
112
127
140
156
169

20,5
26
42
53
68
80,5
97
108
123
134
150
161

20
25,5
41
51,5
66,5
78
94,5
105
120
130
146
157

19
24
38,5
49
62,5
74
89
99,5
113
123
138
149

17,5
23,5
36,5
47,5
59,5
72
85,5
96,5
109
120
134
144

16,5
22
34
45
56
69
81
92,5
103
114
127
138

13,5
20
28,5
41
48,5
62,5
71,5
84
92
104
113
126

10
17
21,5
35
38,5
53,5
59
72
76
89
94,5
108

6,5
13,5
15
28,5
28,5
44
46
60
60
74
75,5
89,5

MXV

25-2
32-4
40-8

Vertical Multi-Stage In-Line Pumps

Dimensions and weights


AD

Counterflanges in stainless steel


43

M
DN

(3)

DN

ISO 228

25
32
40

1
1 1/ 4
1 1/ 2

fM
(1)

(1)

11

DE
DK

Flanges

DG
DN

Holes
DN
25
32
40

h1

h1
(2)

3.93.011/1

3.93.011

(2)

EN 1092-1 PN 25 - 40

DN

DN

af

20 (25 MX4 40-8)

DE
115
140
150

DK
85
100
110

DG
65
76
84

N.

4
4
4

14
19
19

n2 n1

(1) Filling
(2) Draining

s
m2
m1

Pump

MXV 25-204/C
MXV 25-205/C
MXV 25-206/C
MXV 25-207/C
MXV 25-208/C
MXV 25-210/C
MXV 25-212/C
MXV 25-214/C
MXV 25-216/C
MXV 25-218/C
MXV 25-220/C
MXV 32-404/C
MXV 32-405/C
MXV 32-406/C
MXV 32-407/C
MXV 32-408/C
MXV 32-410/C
MXV 32-412/C
MXV 32-414/C
MXV 32-416/C
MXV 32-418/C
MXV 40-804/C
MXV 40-805/C
MXV 40-806/C
MXV 40-807/C
MXV 40-808/C
MXV 40-810/C
MXV 40-811/C
MXV 40-813/C
MXV 40-815/C
MXV 40-817/C
MXV 40-819/C

Motor

kW
0,75
0,75
1,1
1,1
1,5
1,5
2,2
2,2
3
3
3
1,1
1,1
1,5
1,5
2,2
2,2
3
3
4
4
1,5
2,2
2,2
3
3
4
4
5,5
5,5
7,5
7,5

HP
1
1
1,5
1,5
2
2
3
3
4
4
4
1,5
1,5
2
2
3
3
4
4
5,5
5,5
2
3
3
4
4
5,5
5,5
7,5
7,5
10
10

MXV (G)

MXV (F)

threaded
ports

flanged
ports

ISO 228

M80 V1
M80 V1
M80 V1
M80 V1
M90 V1
M90 V1
M90 V1
M90 V1
M100 V1
M100 V1
M100 V1
M80 V1
M80 V1
M90 V1
M90 V1
M90 V1
M90 V1
M100 V1
M100 V1
M112 V1
M112 V1
M90 V1
M90 V1
M90 V1
M100 V1
M100 V1
M112 V1
M112 V1
M132 V1
M132 V1
M132 V1
M132 V1

G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2

DN
25
25
25
25
25
25
25
25
25
25
25
32
32
32
32
32
32
32
32
32
32
40
40
40
40
40
40
40
40
40
40
40

af
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
280
280
280
280
280
280
280
280
280
280
280

with
motor

MXV (G)
(5)

a
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
225
225
225
225
225
225
225
225
225
225
225

without
motor

mm

h1
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
80
80
80
80
80
80
80
80
80
80
80

f
372
396
420
444
478
526
574
622
680
728
776
372
396
430
454
478
526
584
632
680
728
411
441
471
511
541
601
631
711
771
831
891

M
255
255
255
255
255
255
295
295
311
311
311
255
255
255
255
295
295
311
311
311
311
255
295
295
311
311
311
311
339
339
339
339

(5)

fM
627
651
675
699
733
781
869
917
991
1039
1087
627
651
685
709
773
821
895
943
991
1039
666
736
766
822
852
912
942
1050
1110
1170
1230

P
200
200
200
200
200
200
200
200
250
250
250
200
200
200
200
200
200
250
250
250
250
200
200
200
250
250
250
250
300
300
300
300

AD
127,5
127,5
127,5
127,5
127,5
127,5
127,5
127,5
137,5
137,5
137,5
127,5
127,5
127,5
127,5
127,5
127,5
137,5
137,5
137,5
137,5
127,5
127,5
127,5
137,5
137,5
137,5
137,5
159,5
159,5
159,5
159,5

n1
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
246
246
246
246
246
246
246
246
246
246
246

n2
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
215
215
215
215
215
215
215
215
215
215
215

m1
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
190
190
190
190
190
190
190
190
190
190
190

m2
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
130
130
130
130
130
130
130
130
130
130
130

(3) Standard position of terminal box. (for other positions rotate motor through 90 or 180) (4) MXV (F) = MXV (G) + 1kg (5) With standard motor

141

s
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
14
14
14
14
14
14
14
14
14
14
14

(4)

(5)

kg (6)
18
19
20
21
22
23
25
26
29
31
32
19
20
21
22
23
24
27
29
30
31
21
22
23
25
26
28
29
35
36
38
39

kg (6)
30,2
31,2
33,3
34,3
37,2
38,2
43,1
44,1
54,6
56,6
57,6
31,2
32,2
36,2
37,2
41,1
42,1
52,6
54,6
57,8
58,8
36,2
40,1
41,1
50,6
51,6
55,8
56,8
77,3
78,3
85,7
86,7

(6) Net weight

MXV

50-16
65-32
80-48

Vertical Multi-Stage In-Line Pumps

Dimensions and weights


AD

(4)
P

DN 50

DN 65-80

DN
DG
DK
DE

DN
DG
DK
DE

Flanges

EN 1092-2 PN 25 - 40

G 3/8
(1)

Holes

fM
f
G 3/8
(3)

DE

DK

DG

N.

50
65

165
185

125
145

99
118

4
8

19
19

80

200

160

132

19

G 1/8
(2)
DN

DN

G 3/8
(3)

DN

h1

35

4.93.210/2

a
(4)

G 3/8 (3)

260
m4

260

mm

Motor

MXV 50-1603/C
MXV 50-1604/C
MXV 50-1605/C
MXV 50-1606/C
MXV 50-1607/C
MXV 50-1608/C
MXV 50-1609/D
MXV 50-1610/D
MXV 50-1611/D
MXV 50-1612/D
MXV 50-1614/D
MXV 50-1616/D
MXV 65-3202/C
MXV 65-3203/C
MXV 65-3204/C
MXV 65-3205/D
MXV 65-3206/D
MXV 65-3207/D
MXV 65-3208/D
MXV 65-3209/D
MXV 65-3210/D
MXV 65-3212/D
MXV 80-4801/C
MXV 80-4802/C
MXV 80-4803/C
MXV 80-4804/D
MXV 80-4805/D
MXV 80-4806/D
MXV 80-4807/D
MXV 80-4808/D

3
4
5,5
5,5
7,5
7,5
11
11
11
15
15
18,5
4
5,5
7,5
11
11
15
15
18,5
18,5
22
4
5,5
7,5
11
15
15
18,5
22

4
5,5
7,5
7,5
10
10
15
15
15
20
20
25
5,5
7,5
10
15
15
20
20
25
25
30
5,5
7,5
10
15
20
20
25
30

M100 V1
M112 V1
M132 V1
M132 V1
M132 V1
M132 V1
M160 V1
M160 V1
M160 V1
M160 V1
M160 V1
M160 V1
M112 V1
M132 V1
M132 V1
M160 V1
M160 V1
M160 V1
M160 V1
M160 V1
M160 V1
M180 V1
M112 V1
M132 V1
M132 V1
M160 V1
M160 V1
M160 V1
M160 V1
M180 V1

without
motor

with
motor
kg (7)

DN

h1

fM

AD

m4

MXV (5)
kg (7)

50
50
50
50
50
50
50
50
50
50
50
50
65
65
65
65
65
65
65
65
65
65
80
80
80
80
80
80
80
80

300
300
300
300
300
300
300
300
300
300
300
300
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320

90
90
90
90
90
90
90
90
90
90
90
90
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105

395
430
484
519
553
588
652
687
721
756
825
894
407
473
519
595
641
687
733
779
825
917
411
466
527
618
680
741
802
864

311
311
339
339
339
339
459
459
459
484
484
484
311
339
339
459
459
484
484
484
484
538
311
339
339
459
484
484
484
538

706
741
823
858
892
927
1111
1146
1180
1240
1309
1378
718
812
858
1054
1100
1171
1217
1236
1309
1455
722
805
866
1077
1164
1225
1286
1402

250
250
300
300
300
300
350
350
350
350
350
350
250
300
300
350
350
350
350
350
350
350
250
300
300
350
350
350
350
350

137,5
137,5
159,5
159,5
159,5
159,5
186
186
186
186
186
186
137,5
159,5
159,5
186
186
186
186
186
186
206
137,5
159,5
159,5
186
186
186
186
206

322
357
391
426
460
495
529
564
598
633
702
771
334
380
426
472
518
564
610
656
702
794
338
373
434
495
557
618
679
741

42
43
49
51
52
53
62
64
65
67
70
73
45
51
53
62
64
66
68
70
72
75
45
51
54
64
66
69
72
74

(6)

HP

14
220

43

220

kW

4.93.210/3

15

14

Pump

200

(1) Filling and air vent


(3) Draining
(2) Air vent suction side

260

220

G 3/8 (1) (2)

(6)

(4) Standard position of terminal box. (for other positions rotate motor through 90 or 180) (5) MXV (L) : + 3 kg
MXV (H) : + 3 kg

142

(6) With standard motor

(6)

67,6
70,8
91,3
93,3
99,7
100,7
138
140
141
169
172
179,5
72,8
93,3
100,7
138
140
168
170
176,5
178,5
204
72,8
93,3
101,7
140
168
171
178,5
203

(7) Net weight

MXV

100-65 Pompe multistadio verticali in-line


100-90 in acciaio inossidabile

Dimensioni e pesi

AD

(1)

fM

(3)

(1)

11
Flanges
DN

EN 1092-2

DN

140

Holes
DN

DN

PN

DK

100
100

16
25

DE

(2)

DE

DK

230
225

180
190

N.

8
8

19
23

n1

n2

45

N. 4 x 15
m2
m1

Pump

without
motor

mm

Motor

(4)

MXV 100-6501
MXV 100-6502-2R
MXV 100-6502
MXV 100-6503-2R
MXV 100-6503
MXV 100-6504-2R
MXV 100-6504
MXV 100-6505-2R
MXV 100-6505
MXV 100-6506-2R
MXV 100-6506
MXV 100-6507-2R
MXV 100-6507
MXV 100-6508-2R
MXV 100-6508
MXV 100-9001-1R
MXV 100-9001
MXV 100-9002-2R
MXV 100-9002
MXV 100-9003-2R
MXV 100-9003
MXV 100-9004-2R
MXV 100-9004
MXV 100-9005-2R
MXV 100-9005
MXV 100-9006-2R
MXV 100-9006

kW

HP

PN

Size

n1

n2

m1

m2

fm

AD

5,5
7,5
11
15
18,5
18,5
22
30
30
30
37
37
45
45
45
5,5
7,5
11
15
18,5
22
30
30
37
37
45
45

7,5
10
15
20
25
25
30
40
40
40
50
50
60
60
60
7,5
10
15
20
25
30
40
40
50
50
60
60

16
16
16
16
16
16
16
16
16
16
25
25
25
25
25
16
16
16
16
16
16
16
16
16
16
25
25

M132 V1
M132 V1
M160 V1
M160 V1
M160 V1
M160 V1
M180 V1
M200 V1
M200 V1
M200 V1
M200 V1
M200 V1
M225 V1
M225 V1
M225 V1
M132 V1
M132 V1
M160 V1
M160 V1
M160 V1
M180 V1
M200 V1
M200 V1
M200 V1
M200 V1
M225 V1
M225 V1

365
365
365
365
365
365
365
365
365
365
365
365
365
365
365
380
380
380
380
380
380
380
380
380
380
380
380

737
829
849
941
941
1033
1033
1131
1131
1223
1223
1315
1315
1407
1407
737
737
849
849
941
941
1038
1038
1131
1131
1223
1223

316
316
316
316
316
316
316
316
316
316
316
316
316
316
316
341
341
341
341
341
341
341
341
341
341
341
341

265
265
265
265
265
265
265
265
265
265
265
265
265
265
265
280
280
280
280
280
280
280
280
280
280
280
280

240
240
240
240
240
240
240
240
240
240
240
240
240
240
240
260
260
260
260
260
260
260
260
260
260
260
260

190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
199
199
199
199
199
199
199
199
199
199
199
199

339
339
459
484
484
484
538
721
721
721
721
721
818
818
818
339
339
459
484
484
538
721
721
721
721
818
818

1076
1168
1308
1425
1425
1517
1571
1852
1852
1944
1944
2036
2133
2225
2225
1076
1076
1308
1333
1425
1479
1759
1759
1852
1852
2041
2041

300
300
350
350
350
350
350
400
400
400
400
400
450
450
450
300
300
350
350
350
350
400
400
400
400
450
450

159,5
159,5
186
186
186
186
206
315
315
315
315
315
338
338
338
159,5
159,5
186
186
186
206
315
315
315
315
338
338

(4) Standard position of terminal box. (for other positions rotate motor through 90 or 180) (5) MXV (L) : + 3 kg

143

(6) With standard motor

MXV
kg (5)
81
85,5
88,5
93
93
97,5
98
105,5
105,5
110
110
114,5
117,5
122
122
82,5
82,5
89
89
93
93
100
100
104
104
110,5
110,5

with
motor
(4)

kg (5)
123,3
127,8
164,5
195
199,5
204
227
330,5
330,5
335
360
364,5
432,5
437
437
124,8
124,8
165
191
199,5
222
325
325
354
354
425,5
425,5

(7) Net weight

25-2
32-4
40-8

MXV EI

Vertical Multi-Stage In-Line Pumps

Dimensions and weights


AD

Counterflanges in stainless steel


43

M
DN

DN

ISO 228

25
32
40

1
1 1/ 4
1 1/ 2

fM

(3)
(1)

DE

Flanges in accordance
EN 1092-2 PN
- 40 PN 25 - 40
EN 25
1092-1

DK
DG
DN

DN

DN

DN
25
32
40

h1

h1
(2)

Holes

3.93.011/1

3.93.011

(2)

n2 n1

af

20 (25 MXV EI 40-8)

(6)
f

DE
115
140
150

DK
85
100
110

DG
65
76
84

N.

4
4
4

14
19
19

(1) Filling
(2) Draining
(3) Standard position of I-MAT
(for other positions rotate motor through 90 or 180)
(4) MXV EI (F) = MXV EI (G) + 1kg
(5) Net weight
(6) Pressure transducer

AG
AS

s
m2
m1

Motor

Pump

MXV EI 25-204
MXV EI 25-205
MXV EI 25-206
MXV EI 25-207
MXV EI 25-208
MXV EI 25-210
MXV EI 25-212
MXV EI 25-214
MXV EI 25-216
MXV EI 25-218
MXV EI 25-220
MXV EI 32-404
MXV EI 32-405
MXV EI 32-406
MXV EI 32-407
MXV EI 32-408
MXV EI 32-410
MXV EI 32-412
MXV EI 32-414
MXV EI 32-416
MXV EI 32-418
MXV EI 40-804
MXV EI 40-805
MXV EI 40-806
MXV EI 40-807
MXV EI 40-808
MXV EI 40-810
MXV EI 40-811
MXV EI 40-813
MXV EI 40-815
MXV EI 40-817
MXV EI 40-819

kW
0,75
0,75
1,1
1,1
1,5
1,5
2,2
2,2
3
3
3
1,1
1,1
1,5
1,5
2,2
2,2
3
3
4
4
1,5
2,2
2,2
3
3
4
4
5,5
5,5
7,5
7,5

HP
1
1
1,5
1,5
2
2
3
3
4
4
4
1,5
1,5
2
2
3
3
4
4
5,5
5,5
2
3
3
4
4
5,5
5,5
7,5
7,5
10
10

MXV EI (G) MXV EI (F)


threaded
flanged
ports
ports
G

ISO 228

M80 V1
M80 V1
M80 V1
M80 V1
M90 V1
M90 V1
M90 V1
M90 V1
M100 V1
M100 V1
M100 V1
M80 V1
M80 V1
M90 V1
M90 V1
M90 V1
M90 V1
M100 V1
M100 V1
M112 V1
M112 V1
M90 V1
M90 V1
M90 V1
M100 V1
M100 V1
M112 V1
M112 V1
M132 V1
M132 V1
M132 V1
M132 V1

G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2

a
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
225
225
225
225
225
225
225
225
225
225
225

DN
25
25
25
25
25
25
25
25
25
25
25
32
32
32
32
32
32
32
32
32
32
40
40
40
40
40
40
40
40
40
40
40

af
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
280
280
280
280
280
280
280
280
280
280
280

MXV EI
(G)

mm

(4)

h1
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
80
80
80
80
80
80
80
80
80
80
80

f
372
396
420
444
478
526
574
622
680
728
776
372
396
430
454
478
526
584
632
680
728
411
441
471
511
541
601
631
711
771
831
891

144

M
255
255
255
255
255
255
295
295
311
311
311
255
255
255
255
295
295
311
311
311
311
255
295
295
311
311
311
311
339
339
339
339

fM
627
651
675
699
733
781
869
917
991
1039
1087
627
651
685
709
773
821
895
943
991
1039
666
736
766
822
852
912
942
1050
1110
1170
1230

P
200
200
200
200
200
200
200
200
250
250
250
200
200
200
200
200
200
250
250
250
250
200
200
200
250
250
250
250
300
300
300
300

AD
286
286
286
286
286
286
286
286
294
294
294
286
286
286
286
286
286
294
294
294
294
286
286
286
294
294
294
294
321
321
368
368

AG
190
190
190
190
190
190
210
210
210
210
210
190
190
190
190
210
210
210
210
210
210
190
210
210
210
210
210
210
210
210
281
281

AS
105
105
105
105
105
105
118
118
118
118
118
105
105
105
105
118
118
118
118
118
118
105
118
118
118
118
118
118
118
118
153
153

n1
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
246
246
246
246
246
246
246
246
246
246
246

n2
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
215
215
215
215
215
215
215
215
215
215
215

m1
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
190
190
190
190
190
190
190
190
190
190
190

m2
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
130
130
130
130
130
130
130
130
130
130
130

s
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
14
14
14
14
14
14
14
14
14
14
14

kg (5)
36,6
37,6
39,7
40,7
43,8
44,8
50,6
51,6
62,1
64,1
65,1
37,6
38,6
42,8
43,8
48,6
49,6
60,1
62,1
65,8
66,8
42,8
47,6
48,6
58,6
59,6
63,8
64,8
85,3
86,3
100,5
101,5

50-16
65-32
80-48

MXV EI

Vertical Multi-Stage In-Line Pumps

Dimensions and weights


AD

M
P

(4)

DN 50

DN 65-80

DN
DG
DK
DE

DN
DG
DK
DE

Flanges in accordance
EN 1092-2 PN 25
- 40
EN
1092-2 PN 25 - 40

G 3/8
(1)
fM

f
G 3/8
(3)

G 1/8
(2)

DE

DK

DG

N.

50
65

165
185

125
145

99
118

4
8

19
19

80

200

160

132

19

(7)
DN

DN

G 3/8
(3)

h1

35

4.93.210/2

(4)

AS

G 3/8 (3)

MXV EI 50-1603
MXV EI 50-1604
MXV EI 50-1605
MXV EI 50-1606
MXV EI 50-1607
MXV EI 50-1608
MXV EI 50-1609
MXV EI 50-1610
MXV EI 50-1611
MXV EI 65-3202
MXV EI 65-3203
MXV EI 65-3204
MXV EI 65-3205
MXV EI 65-3206
MXV EI 80-4801
MXV EI 80-4802
MXV EI 80-4803
MXV EI 80-4804

14

15

14

(1) Filling and air vent


(2) Air vent suction side
(3) Draining
(4) Standard position of I-MAT
(for other positions rotate motor through 90 or 180)
(5) MXV (L) : + 3 kg, MXV (H) : + 3 kg
(6) Net weight
(7) Pressure transducer

220

43

220

260
m4

260

Motor

Pump

200

220

260

G 3/8 (1) (2)

AG

MXV EI

mm

(5)
kW

HP

3
4
5,5
5,5
7,5
7,5
11
11
11
4
5,5
7,5
11
11
4
5,5
7,5
11

4
5,5
7,5
7,5
10
10
15
15
15
5,5
7,5
10
15
15
5,5
7,5
10
15

M100 V1
M112 V1
M132 V1
M132 V1
M132 V1
M132 V1
M160 V1
M160 V1
M160 V1
M112 V1
M132 V1
M132 V1
M160 V1
M160 V1
M112 V1
M132 V1
M132 V1
M160 V1

DN

h1

fM

AD

AG

AS

m4

kg (6)

50
50
50
50
50
50
50
50
50
65
65
65
65
65
80
80
80
80

300
300
300
300
300
300
300
300
300
320
320
320
320
320
320
320
320
320

90
90
90
90
90
90
90
90
90
105
105
105
105
105
105
105
105
105

395
430
484
519
553
588
652
687
721
407
473
519
595
641
411
466
527
618

311
311
339
339
339
339
459
459
459
311
339
339
459
459
311
339
339
459

706
741
823
858
892
927
1111
1146
1180
718
812
858
1054
1100
722
805
866
1077

250
250
300
300
300
300
350
350
350
250
300
300
350
350
250
300
300
350

294
294
321
321
368
368
393
393
393
294
321
368
393
393
294
321
368
393

210
210
210
210
281
281
281
281
281
210
210
281
281
281
210
210
281
281

118
118
118
118
153
153
153
153
153
118
118
153
153
153
118
118
153
153

322
357
391
426
460
495
529
564
598
334
380
426
472
518
338
373
434
495

75,1
78,8
99,3
101,3
114,5
115,5
152,8
154,8
155,8
80,8
101,3
115,5
152,8
154,8
80,8
101,3
116,5
154,8

145

11

Holes
DN

MXV EI

100-65
100-90

Vertical Multi-Stage In-Line Pumps

Dimensions and weights

AD

(3)

fM

(1)(5)

(1)

Flanges in accordance
EN 1092-2
EN 1092-2
DN

DN

140

Holes
DN

DN

PN

DE

DK

DK

100
100

16
25

230
225

180
190

DE

(2)

N.

8
8

19
23

AG

(1) Filling and air vent


(2) Draining
(3) Standard position of I-MAT
(for other positions rotate motor through 90 or 180)
(4) Net weight
(5) Pressure transducer

n1

n2

45

AS
m2
N. 4 x 15

m1

Motor

Pump

mm
MXV EI

MXV EI 100-6501
MXV EI 100-6502-2R
MXV EI 100-6502
MXV EI 100-9001-1R
MXV EI 100-9001
MXV EI 100-9002-2R

kW

HP

PN

Size

n1

n2

m1

m2

fm

AD

AG

AS

kg (4)

5,5
7,5
11
5,5
7,5
11

7,5
10
15
7,5
10
15

16
16
16
16
16
16

M132 V1
M132 V1
M160 V1
M132 V1
M132 V1
M160 V1

365
365
365
380
380
380

737
829
849
737
737
849

316
316
316
341
341
341

265
264
265
280
280
280

240
240
240
260
260
260

190
190
190
199
199
199

339
339
459
339
339
459

1076
1168
1308
1076
1076
1308

300
300
350
300
300
350

321
368
393
321
368
393

210
281
281
210
281
281

118
153
153
118
153
153

131,3
142,6
179,3
132,8
139,6
179,8

146

MXV4

25-2

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 1450 rpm


0

Imp. g.p.m.

2.5

7.5

60

MXV4 25-220

50

160

18

m
ft

16

40

11

120

14
12

30

10

80

8
7
6
5
4

20

10

40

0
0

m3/h
l/min

0.5

1.5

1
10

20

2.5

30

40

50
40

0.025

Pst

0.02
Pst
kW
0.01

%
20
10

0.005
4

0
1

ft

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

NPSH
2

0.5

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

m
0
0

Pst = Power with reference to one stage.

0
m3/h

Pump type
MXV4 25-204
MXV4 25-205
MXV4 25-206
MXV4 25-207
MXV4 25-208
MXV4 25-210
MXV4 25-212
MXV4 25-214
MXV4 25-216
MXV4 25-218
MXV4 25-220

0,5

1.5

Motor power
kW

HP

0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55

0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75

m3/h
l/min

H
m

72.1025

2.5

0,6

0,9

1,2

10

15

20

11,5
14,5
17,5
20,5
23
29
35
40,5
46,5
52
58

10,5
13
16
18,5
21
26,5
31,5
37
42
47,5
52,5

10
12
14,5
17
19,5
24,5
29,5
34,5
39
44
49

9
11
13
15,5
17,5
22
26,5
31
35
39,5
44

147

1,8

2,2

25

30

36,6

7,5
9,5
11,5
13,5
15
19
23
26,5
30,5
34
38

6,5
8
9,5
11
13
16
19
22,5
25,5
29
32

4
5
6
7
8
10
12
14
16,5
18,5
21

1,5

MXV4

32-4

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 1450 rpm


Imp. g.p.m.

10

60

50

160

MXV4 32-418
H
m

ft

40

16
120

14
30

12
10

80

8
7
6
5
4

20

10

40

0
0
0

m3/h
l/min

20

40

60

60

50

0.03
Pst
kW
0.02

%
Pst

30
20

0.01
4

10
1
NPSH
m
0.5

ft

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.

0
0

m /h

Pump type

MXV4 32-404
MXV4 32-405
MXV4 32-406
MXV4 32-407
MXV4 32-408
MXV4 32-410
MXV4 32-412
MXV4 32-414
MXV4 32-416
MXV4 32-418

Motor power
kW

HP

0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55

0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75

m3/h
l/min

H
m

72.1026

0,9

1,2

15

11
14
17
19,5
22,5
28
33,5
39
45
51

10,5
13
15,5
18
21
26
31
36,5
41,5
47

148

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

1,8

2,4

3,6

20

30

10
12,5
15
17,5
20
25
30
35
40
45

9,5
12
14
16,5
19
23,5
28
33
37,5
42

40

50

60

8
10
12
14
16
20
24
28
32
36

6,5
8
9,5
11
13
16
19
22,5
25,5
29

4
5
6
7
8
10
12
14
16
18

MXV4

40-8

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 1450 rpm


0

Imp. g.p.m. 10

15

20

25

60

MXV4 40-819
50

160

17

ft

40

15
120

11

13
30

11
10
80

8
20

7
6
5
4

10

0
0
0

m3/h 1
l/min

40

20

40

60

80

100

80

0.06

70

0.05

Pst

0.04
Pst
kW
0.02

50
40
30
3

0.01

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

NPSH
2

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

ft

m
4

Pst = Power with reference to one stage.


0

m3/h 1

Pump type
MXV4 40-804
MXV4 40-805
MXV4 40-806
MXV4 40-807
MXV4 40-808
MXV4 40-810
MXV4 40-811
MXV4 40-813
MXV4 40-815
MXV4 40-817
MXV4 40-819

Motor power
kW

HP

0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,75
0,75
1,1
1,1

0,75
0,75
0,75
0,75
0,75
0,75
0,75
1
1
1,5
1,5

72.993

m3/h

2,7

3,6

4,2

4,8

5,4

6,9

l/min

33,5

45

60

70

80

90

100

115

11,5
14,5
17,5
20
23
29
32
38
43,5
49
55

11
14
16,5
19
22
27,5
30
36
41
47
52

10,5
13
16
18,5
21
26
29
34
39,5
44,5
50

9,5
12
14,5
17
19,5
24
26,5
31,5
36,5
41
46

9
11,5
13,5
16
18
23
25
29,5
34
39
43

8,5
10,5
12,5
15
17
21
23
27
31,5
36
40

7,5
9,5
11,5
13,5
15
19
21
25
28,5
32
36

6,5
8
10
11,5
13
16,5
18
21,5
25
28
31,5

5
6
7
8,5
9,5
12
13
15,5
18
20,5
23

H
m

149

MXV4 50-16

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 1450 rpm


Imp. g.p.m.

70

20

30

50

40

MXV4 50-1616
200

60

14
ft
50

160

12

H
m

11

40

10
120

9
8

30

7
80

6
5

20

4
3

40

10

0
0
0

m3/h 2
l/min

0
4

50

100

10

12

150

14

200

70

0.20

60

%
40

0.16
Pst
kW
0.08

Pst

30

0.04

20
3

NPSH

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012
Head and power values valid for liquids with
density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

ft

1
0.5
0

m3/h 2

Pump type
MXV4 50-1603
MXV4 50-1604
MXV4 50-1605
MXV4 50-1606
MXV4 50-1607
MXV4 50-1608
MXV4 50-1609
MXV4 50-1610
MXV4 50-1611
MXV4 50-1612
MXV4 50-1614
MXV4 50-1616

Motor power
kW

HP

2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2

3
3
3
3
3
3
3
3
3
3
3
3

m3/h
l/min

H
m

10

12

3,6

72.994

Pst = Power with reference to one stage.

14

4,5

7,5

10,5

12,9

60

75

100

125

150

175

215

12,3
16,5
20,5
24,5
29
33
37
41
45
49
57,5
65,5

11,5
15,5
19,5
23
27
31
35
39
42,5
46,5
54
62

11,5
15,5
19
23
27
30,5
34,5
38,5
42
46
53,5
61,5

11
14,5
18,5
22
25,5
29,5
33
36,5
40,5
44
51,5
58,5

10
13,5
17
20,5
24
27
30,5
34
37,5
41
47,5
54,5

9
12
15,5
18,5
21,5
24,5
27,5
30,5
34
37
43
49

7,5
10
12,5
15
17,5
20
22,5
25
27,5
30
35
40

3
4
5
6
7
8
9
10
11,5
12,5
14,5
16,5

150

MXV4 65-32

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 1450 rpm


25

Imp. g.p.m.

50

75

54

MXV4 65-3212
50
160

ft

10
40

H
m

120

30

11

7
6

80

5
20

4
3
10

40

0
0

m3/h
l/min

10

15

100

20

200

80

25
400

300

Pst

70

0.2
Pst
kW
0.1

50

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

40
30

0
8

2
NPSH
m

ft

0
0

m3/h

Pump type

MXV4 65-3202
MXV4 65-3203
MXV4 65-3204
MXV4 65-3205
MXV4 65-3206
MXV4 65-3207
MXV4 65-3208
MXV4 65-3209
MXV4 65-3210
MXV4 65-3212

10

15

Motor power
kW

HP

2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
3
3

3
3
3
3
3
3
3
3
4
4

20

72.995

25

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.

m3/h

11

13

15

17

19

23,4

l/min

116,6

150

183

216

250

283

316

390

9
13
17,5
22
26
31
35
39
44
53

8,2
12,3
16,5
20,5
25
29
33
37
41
49

8
12
16
20
24
28
32
36
40
48

7,7
11,5
15,5
19
23
27
30,5
34,5
38,5
46

7,4
11
15
18
22
25,5
29,5
33
36,5
44

7
10
13,5
17
20,5
24
27
30,5
34
41

6,5
9,5
12,5
16
19
22
25,5
28,5
32
38

6
8,5
11,5
14
17
20
23
25,5
28,5
34

3
4
6
7
8,5
10
11,5
13
14,5
17,5

H
m

151

MXV4 80-48

Vertical Multi-Stage In-Line Pumps

Characteristic curves and performance n 1450 rpm


25 Imp. g.p.m. 50

40

125

100

75

MXV4 80-4808
120

ft

7
30

6
80

5
20

3
40
10

0
0
0

m3/h 5
l/min 100

0
10

15

20

200

300

30
500

25
400

35

80

0.6

70

0.5
0.4
Pst
kW
0.2

Pst

50
40
30
3

0.1
8

NPSH
2
m

ft

1
0

Test results with clean cold water, without gas


content.
A safety margin of + 0.5 m is recommended for
the NPSH value.
Tolerances in accordance with UNI EN ISO 9906:2012

m3/h

Pump type
MXV4 80-4803
MXV4 80-4804
MXV4 80-4805
MXV4 80-4806
MXV4 80-4807
MXV4 80-4808

10

15

20

Motor power
kW

HP

2,2
2,2
2,2
2,2
2,2
3

3
3
3
3
3
4

m3/h
l/min

H
m

25

30

12

150

200

15,5
21
26
31
36,5
41,5

14
19
23,5
28
33
37,5

13
18
22
26,5
31
35,5

152

72.1037

35

Head and power values valid for liquids with


density = 1,0 kg/dm3 and kinematic viscosity
= max 20 mm2/sec.

Pst = Power with reference to one stage.

15

18

21

24

27

30

250

300

350

400

450

500

12,5
17
21
25
29,5
33,5

11,5
15,5
19,5
23,5
27
31

11
14,5
18
21,5
25
29

9,5
13
16
19
22,5
25,5

8
11
13,5
16
19
21,5

6,5
8,5
11
13
15
17

25-2
32-4
40-8

MXV4

Vertical Multi-Stage In-Line Pumps

Dimensions and weights


AD

Counterflanges in stainless steel


43

M
DN

(3)

DN

ISO 228

25
32
40

1
1 1/ 4
1 1/ 2

fM
(1)

(1)

11

DK

Flanges

DG
DN

Holes
Holes
DN
25
32
40

h1

h1
(2)

EN 1092-1 PN 25 - 40

DN

DN

3.93.011/1

3.93.011

(2)

af

20 (25 MXV4 40-8)

DE

DE
115
140
150

DK
85
100
110

DG
65
76
84

N.

4
4
4

14
19
19

n2 n1

(1) Filling
(2) Draining

s
m2
m1

Pump

MXV4 25-204
MXV4 25-205
MXV4 25-206
MXV4 25-207
MXV4 25-208
MXV4 25-210
MXV4 25-212
MXV4 25-214
MXV4 25-216
MXV4 25-218
MXV4 25-220
MXV4 32-404
MXV4 32-405
MXV4 32-406
MXV4 32-407
MXV4 32-408
MXV4 32-410
MXV4 32-412
MXV4 32-414
MXV4 32-416
MXV4 32-418
MXV4 40-804
MXV4 40-805
MXV4 40-806
MXV4 40-807
MXV4 40-808
MXV4 40-810
MXV4 40-811
MXV4 40-813
MXV4 40-815
MXV4 40-817
MXV4 40-819

Motor

kW
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,55
0,75
0,75
1,1
1,1

HP
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
0,75
1
1
1,5
1,5

MXV (G)

MXV (F)

threaded
ports

flanged
ports

ISO 228

80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 A4
80 B4
80 B4
90 S4
90 S4

G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2

(5)

a
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
225
225
225
225
225
225
225
225
225
225
225

DN
25
25
25
25
25
25
25
25
25
25
25
32
32
32
32
32
32
32
32
32
32
40
40
40
40
40
40
40
40
40
40
40

af
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
280
280
280
280
280
280
280
280
280
280
280

without
motor

mm

h1
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
80
80
80
80
80
80
80
80
80
80
80

f
372
396
420
444
468
516
564
612
660
708
756
372
396
420
444
468
516
564
612
660
708
401
431
461
491
521
581
611
671
741
801
861

M
fM
P
234 606 200
234 630 200
234 654 200
234 678 200
234 702 200
234 750 200
234 798 200
234 846 200
234 894 200
234 942 200
234 990 200
234 606 200
234 630 200
234 654 200
234 678 200
234 702 200
234 750 200
234 798 200
234 846 200
234 894 200
234 942 200
234 635 200
234 665 200
234 695 200
234 725 200
234 755 200
234 815 200
234 845 200
234 905 200
234 965 200
282 1083 200
282 1143 200

(5)

AD
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
128
128

n1
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
210
246
246
246
246
246
246
246
246
246
246
246

n2
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
215
215
215
215
215
215
215
215
215
215
215

m1
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
190
190
190
190
190
190
190
190
190
190
190

m2
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
130
130
130
130
130
130
130
130
130
130
130

s
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
14
14
14
14
14
14
14
14
14
14
14

(3) Standard position of terminal box. (for other positions rotate motor through 90 or 180) (4) MXV4 (F) = MXV4 (G) + 1kg (5) With standard motor

153

MXV (G) (4)


kg (6)
18
19
20
21
22
23
25
26
28
30
31
19
20
21
22
23
25
26
28
30
32
21
22
23
25
26
28
29
31
33
35
37

with
motor
(5)

kg (6)
26
27
28
29
30
31
33
34
36
38
39
27
28
29
30
31
33
34
36
38
42
29
30
31
33
34
38
39
41
43
48
50

(6) Net weight

MXV4

50-16
65-32
80-48

Vertical Multi-Stage In-Line Pumps

Dimensions and weights


AD

(4)
P

DN 50

DN 65-80

DN
DG
DK
DE

DN
DG
DK
DE

Flanges

EN 1092-2 PN 25 - 40

G 3/8
(1)

Holes

fM
f

G 1/8
(2)
DN

DN

G 3/8
(3)

G 3/8
(3)

DN

DE

DK

DG

N.

50
65

165
185

125
145

99
118

4
8

19
19

80

200

160

132

19

h1

35

4.93.210/2

a
(4)

G 3/8 (3)
14
220

220

43

260
m4

mm

Motor

MXV4 50-1603
MXV4 50-1604
MXV4 50-1605
MXV4 50-1606
MXV4 50-1607
MXV4 50-1608
MXV4 50-1609
MXV4 50-1610
MXV4 50-1611
MXV4 50-1612
MXV4 50-1614
MXV4 50-1616
MXV4 65-3202
MXV4 65-3203
MXV4 65-3204
MXV4 65-3205
MXV4 65-3206
MXV4 65-3207
MXV4 65-3208
MXV4 65-3209
MXV4 65-3210
MXV4 65-3212
MXV4 80-4803
MXV4 80-4804
MXV4 80-4805
MXV4 80-4806
MXV4 80-4807
MXV4 80-4808

HP

2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
3
3
2,2
2,2
2,2
2,2
2,2
3

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
3
3
3
3
3
4

100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LB4
100 LB4
100 LA4
100 LA4
100 LA4
100 LA4
100 LA4
100 LB4

without
motor

with
motor

DN

h1

fM

AD

m4

MXV4 (5)
kg (7)

kg (7)

50
50
50
50
50
50
50
50
50
50
50
50
65
65
65
65
65
65
65
65
65
65
80
80
80
80
80
80

300
300
300
300
300
300
300
300
300
300
300
300
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320

90
90
90
90
90
90
90
90
90
90
90
90
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105

395
430
464
499
533
568
602
637
671
706
775
844
407
453
499
545
591
637
683
729
775
867
507
568
630
691
752
814

336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336
336

731
766
800
835
869
904
938
973
1007
1042
1111
1180
743
789
835
881
927
973
1019
1065
1111
1203
843
904
966
1027
1088
1150

250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250

166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166
166

322
357
391
426
460
495
529
564
598
633
702
771
334
380
426
472
518
564
610
656
702
794
434
495
557
618
679
741

42
43
45
46
48
49
51
52
54
55
58
61
45
47
49
51
52
54
56
58
60
62
50
53
55
58
61
63

66
67
69
70
72
73
75
76
78
79
82
87
69
71
73
75
76
78
80
84
86
90
74
77
79
82
87
89

(6)

kW

14

15

260

Pump

4.93.210/3

200

(1) Filling and air vent


(3) Draining
(2) Air vent suction side

260

220

G 3/8 (1) (2)

(6)

(4) Standard position of terminal box. (for other positions rotate motor through 90 or 180) (5) MXV4 (L) : + 3 kg
MXV4 (H) : + 3 kg

154

(6) With standard motor

(6)

(7) Net weight

MXV

Vertical Multi-Stage In-Line Pumps

Features
Long Service Life with Standard Motor
Pump with thrust bearing without additional axial loads on the
motor bearings.
Any standard motor V1 design (suitable to be lifted in vertical position) can be used, of our choice or of Clients choice.

Easy Assembly of the Motor


With the single-piece sleeve coupling the pump unit can be supplied
fully assembled also without the motor. This eliminates the risk of
damage caused by shifting of the pump shaft during transportation.
The motor is simply inserted in the coupling and fastened to the
flange without the necessity for adapting the axial position of the
pump shaft.

11

Extra Safety
Single-piece coupling guard to be removed only by means of a tool,
positioned around the lantern bracket, thus avoiding accidental
pushing and rubbing against the coupling.
3.93.029

MXV 25-2, 32-4, 40-8


Low Cost Installation
Vertical construction with reduced pump height for installation in
small spaces.
In-line connections to simplify the piping layout with the possibility
of inserting the pump in straight pipe-lines.
Disassembly, inspection or cleaning of internal parts without
removal of piping.

Robust and Reliable


Single PN 25 construction for all pump sizes.
The suction and discharge nozzles arranged in-line absorb the forces
of the piping on the pump without the creation of distorting loads
causing local friction and early wears.
The lantern brackets compact and robust design maintains a sure
alignment between rotating and fixed parts, reducing vibration.
The upper cover design prevents entrapment of air around the
mechanical seal.

Low-Noise Operation
The water filled shroud around the stages and thick external walls,
work together for low-noise operation.
Low-noise standard motor.

3.93.112

MXV 50-16, 65-32, 80-48


155

MXVL AISI 316L

Vertical Multi-Stage In-Line Pumps


Construction
Vertical multi-stage pumps with suction and delivery connections of
the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped liquid.
A pump with thrust bearing and sleeve coupling for use of any
standard motor with IM V1 construction.

Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-boosting
systems, fire-extinguishing systems, high-pressure washing
plants, irrigation, agricultural uses and sport installations.

Operating conditions
Temperature of liquid: from -15 C to +110 C.
Operating environment temperature: up to 40 C.
Maximum permissible pressure in pump casing: 25 bar.

Motor
Standard-type: 2-4 pole induction motor, 50 Hz.
Construction IM V1 (EN 60034-7).
Motor suitable for operation with frequency converter.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from 7,5 kW.
Insulation class F).
Protection IP 55.
three-phase with rated voltage: up to 3 kW 230/400 V;
from 4 kW 400/690 V.
The electropumps MXVL series comply with the European Regulation no.
547/2012.

MXVL 25, 32, 40

Rated speed of rotation (50 Hz):

MXVL 2900 rpm


MXVL4 1450 rpm.

MXVL 50, 65, 80, 100

All parts that come into contact with the liquid, including wet-end
covers, are in chrome-nickel-molybdenum stainless steel AISI 316L.

Internal parts in contact with the liquid with pump casing and upper
cover in chrome-nickel-molybdenum stainless steel AISI 316L.

Materials (wetted parts)

Materials (wetted parts)

Component
Flange
External jacket
Suction casing
Delivery casing
Stage casing
Impeller
Lower cover
Upper cover
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing
Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

Component
Pump casing
Upper cover
External jacket
Stage casing
Impeller
Spacer sleeve
Pump shaft
Plug
Bearing sleeve
Bearing in stage casing

Material

Stainless Steel
1.4404 EN 10088 (AISI 316L)

Stainless Steel
1.4404 EN 10088 (AISI 316L)
Corrosion-resistant, cemented carbide
Ceramic alumina

Mechanical seal
ISO 3069 - KU
Wear ring
O-rings

Hard metal/Carbon/EPDM.

PTFE
NBR

Material
Stainless Steel
1.4404 EN 10088 (AISI 316L)
Stainless Steel
1.4404 EN 10088 (AISI 316L)
Stainless Steel (AISI 316L)(AISI 329 for MXVL 100)
Stainless Steel 1.4404 EN 10088 (AISI 316L)
Corrosion-resistant, cemented carbide
Ceramic alumina
(Corrosion-resistant, cemented carbide for MXVL 100)
Hard metal/Carbon/EPDM

PTFE
NBR (EPDM for MXV 100)

Direction of rotation: clockwise as seen from the motor.

Direction of rotation: anticlockwise as seen from the motor.


(clockwise as seen from the motor for MXVL 100)

Variants (to be specified when ordering)

Variants (to be specified when ordering)

Pump with threaded ports (G).


Pump with flanged ports (F).
Pump without motor.
Pump with standard motor.

Pump without motor.


Pump with standard motor.

Other variants (on request)

Other variants (on request)

O-rings FPM. Other mechanical seal.


Pump with motor of Client's choice (if available).
Other voltage ratings.
Frequency 60 Hz.
Pump with support feet for horizontal installation (H1 or H2).
Support feet for horizontal installation, set.
Welding counter-flanges, PN 25 (steel).

With counter-flanges in chrome-nickel steel.


O-rings FPM. Other mechanical seal.
Pump with motor of Client's choice (if available).
Single-phase motor 230 V, up to 2.2 kW.
Other voltage ratings.
Frequency 60 Hz.

156

MXVL AISI 316L

Vertical Multi-Stage In-Line Pumps

MXVL 25, 32, 40

MXVL 50, 65, 80, 100

Designation

Designation
MXV L 4 EI 25-205

G *

MXV L 4 EI 50-1605

Series
AISI 316L vesion
4 pole (no code = 2 pole)
With frequency converter I-MAT
DN ports in mm
Rated capacity in m3/h (n 2900 rpm)
Number of stages

Series
AISI 316L vesion
4 pole (no code = 2 pole)
With frequency converter I-MAT
DN ports in mm
Rated capacity in m3/h (n 2900 rpm)
Number of stages

Construction variants
special seal code (no code = standard seal)
threaded ports
flanged ports
with motor (or without motor)
* with no further designation = with standard motor

Construction variants
special seal code (no code = standard seal)
with support feet for horizontal installation H, variant 1
with motor (or without motor)
* with no further designation = with standard motor

G
F

H1 *

11.1

Installations

Pipe connection

4.93.213/1

Vertical installation
(Standard).

4.93.213/2

4.93.213/3

4.93.213/4

3.93.013

Pump with threaded ports:


pipes screwed into the ports

Pump with threaded ports:


pipes with union couplings
(locally available)

Horizontal installation.

Pump with flanged ports:


pipes with counter-flanges

Pump size

Number
of stages

Stage casings
with bearing

40 - 804
40 - 805
40 - 806
40 - 807
40 - 808
40 - 810

4
5
6
7
8
10

1
1
1
1
1
1

40 - 811

11
12
13
14
15
16
18

2
2
2
2
2
2
2

17
19
20

3
3
3

MXVL
MXV4L
MXV - -MXV4
32 - 404
32 - 405
32 - 406
32 - 407
32 - 408
32 - 410

25 - 212

32 - 412

25 - 214

32 - 414

40 - 813
40 - 815
25 - 216
25 - 218

32 - 416
32 - 418
40 - 817
40 - 819

25 - 220

Variant H2:
suction on the right,
delivery on the left.

Variable parts

Variable parts

25 - 204
25 - 205
25 - 206
25 - 207
25 - 208
25 - 210

Variant H1:
suction on the left,
delivery on the right.

Pump size

Number
of stages

Stage casings
with bearing

80 - 4801
80 - 4802
80 - 4803
80 - 4804
80 - 4805

1
2
3
4
5
6
7
8
9
10

1
1
1
1
1
1
1
1
1
1

80 - 4806
80 - 4807
80 - 4808

6
7
8
9
10
11
12
14
16

2
2
2
2
2
2
2
2
2

MXVL
MXV - MXV4L
MXV4

50 - 1603
50 - 1604
50 - 1605
50 - 1606
50 - 1607
50 - 1608
50 - 1609
50 - 1610

65 - 3202
65 - 3203
65 - 3204
65 - 3205
65 - 3206
65 - 3207

65 - 3208
65 - 3209
65 - 3210
50 - 1611
50 - 1612
50 - 1614
50 - 1616

157

65 - 3212

MXVL AISI 316L

Vertical Multi-Stage In-Line Pumps

Coverage chart
4

Imp. g.p.m.

10

20

30

40

50

100

200

300

400

500

250
800

MXVL
n 2900 1/min

700
200

ft

500

150

25-2

40-8

32-4

65-32

50-16

400

100-65
100

300

100-90

80-48

200

50
100

m3 /h
l/min

2
30

3
40

50

9 10
150

100

16
200

20

32

300

400

40

48

500

60

0
150

70 80 90100

1000

1500

2000
72.936/1

Imp. g.p.m.

10

20

30

40

50

100

64
60

200

MXVL4
n 1450 1/min

180

50

160

140

50-16

40

ft

100

30

25-2

65-32

40-8

32-4

80
20
60

80-48
40
10
20

0
0,6
10

0,8

1
20

m 3/h
l/min

30

3
40

50

6
100

9 10
150

16
200

20
300

30
400

40

500
72.1036

For characteristic curves, dimensions and weights see cap. 11


158

09/2016

SPA

Self-Draining Whirlpool Pumps

Compact Spa

Construction
Self-draining, single-impeller pumps, with motor insulated
from pumped water, constructed with high quality, corrosionproof plastic materials, with stainless steel diffuser.
Compact design (158 mm wide).
PVC pipe connections:
Ports for cementing joint, with external thread for union coupling.

Applications
For spas, hydromassage bathtubs and whirlpool baths.

Operating conditions
Water temperature up to 60 C.
Room temperature up to 40 C.
Maximum permissible pressure in the pump casing: 2,5 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
SPA:
three-phase 230/400 V 10%.
SPAM:single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP X5.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component

Material

Pump casing
Union coupling

ABS (Acrylonitrile-Butadiene-Styrene)

Diffuser cover
Impeller

Glass reinforced
thermoplastic: PPO-GF30, NORYL*

Diffuser-wall
with wear-ring

Cr-Ni-Mo stainless steel


1.4401 EN 10088 (AISI 316)

Mechanical seal

Ceramic alumina, Carbon, FPM

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).

* Trademark of General Electric

Coverage chart n 2800 rpm


0
0

Imp. g.p.m.
U.S. g.p.m.

20
20

60

40
40

60

80

20
60

H
m

ft

40
10

41
20

SPA 11

0
0
0

m 3/h
l/min

6
100

21

31

18
300

12
200

72.917.2

159

12

SPA

Self-Draining Whirlpool Pumps

Compact Spa

Performance n 2800 rpm


3~

230 V 400 V

SPA 11
SPA 21/A

1~

230 V

P1

P2

kW

kW

HP

2,8

1,6

SPAM 11

3,3

0,73

0,45

0,6

1,7

SPAM 21/A

4,5

0,55

0,75

5,4

1,2

0,75

1,6

1,1

1,5

SPA 31/A

3,7

2,2

SPAM 31/A

SPA 41

4,7

2,7

SPAM 41

P1 Max. power input.

l/min

P2 Rated motor power output.

m3/h

H m

12

13

16

17

18

266

283

300

50

100

150

200

216

12

11,1

9,7

7,8

5,6

4,7

14,5

13,4

12,1

10,2

7,9

7,2

16,1

15,2

13,9

12,4

10,2

9,3

6,8

5,8

17,3

16,5

15,3

14

12,4

11,8

9,5

8,6

7,7

Tolerances in accordance with UNI EN ISO 9906:2012

Total head in m.

Dimensions and weights


SPA 11, 21/A, 31/A
fM

158

70

w1

SPA SPAM

97

6,7

SPA 11

339 176 34

26 122

SPA 21/A

371 191 39

31 136 102

SPA 31/A

371 191 39

31 136 102

10

6,8

146

m2

180

m1

34

fM

10

Type
TIPO

kg

mm

3.93.070

m1
w

9
112

8
w1

m2

146

SPA 41
419

158

50

70

Cemented joint.

G 2 1/4
ISO 228
50

34

10
4.93.225/1

Threaded union coupling.


3.93.070

32

142

30

100

125

117

SPA 41 14,0 kg
SPAM 41 15,5 kg

155

Features
Diffuser with peripheral-longitudinal flow,
of stainless steel for extra reliability.

4.93.035

Mechanical seal without contact with


the shaft, for extra safety.

3.93.033/1

160

180

208

146

25

09/2016

MPC

Self-Priming Swimming Pool Pumps

Compact Pool

Construction
Self-priming swimming pool pumps with built-in strainer and
motor insulated from pumped water.
The pump is made with high quality plastic materials, corrosion
and sand erosion resistant.
With stainless steel diffuser.
Base-plate kit.

Applications
- For water circulation in swimming pool filtration systems.
- For clean or slightly dirty water with solids in suspension.

Operating conditions
Water temperature up to 60 C.
Ambient temperature up to 40 C.
Maximum permissible pressure in the pump casing 2,5 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
MPC: three-phase 230/400 V 10%.
MPCM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP X4.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materiali
Component

Material

Special features on request

Pump casing
Diffuser cover
Impeller

Glass reinforced
thermoplastic
PPO-GF30, NORYL

- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).

Strainer cover

Transparent polycarbonate, LEXAN

Strainer basket

Polypropylene

Patents:

EP 0 460 597
US 5 226 790

Certification marks for MPCM, up to 1,5 kW:

Diffuser funnel
and wear-ring

Cr-Ni-Mo steel AISI 316

Mechanical seal

Ceramic alumina, Carbon, FPM

SUD

geprfte
Sicherheit

Coverage chart n 2800 rpm


0 Imp. g.p.m.

20

0 U.S. g.p.m. 20

40

60

40

60

80
80

100

100

120

120

140

140

160

180

20
60
ft

H
m

40
10

MPC 71

41
11

0
0

m 3/h
l/min

21

20

61

31

MPCM 71

51

12

18

24

30

36

100

200

300

400

500

600

42

700
72.859.2

161

13

MPC

Self-Priming Swimming Pool Pumps

Compact Pool

Performance n 2800 rpm


3~

230 V 400 V

1~

230 V P1

P2

kW

kW

HP

1,6

MPCM 11

3,3 0,73

0,37

0,5

MPC 21/A

1,7

MPCM 21/A

4,5

0,55

0,75

13,4

MPC 31/A

3,7

2,2

MPCM 31/A

5,4

1,2

0,75

15,6

MPC 41

4,7

2,7

MPCM 41

1,6

1,1

1,5

16,4

16,2

3~

230 V 400 V

1~

230 V P1

l/min

2,8

MPC 11

m3/h

P2

12

15

18

21

300

350

50

100

150

200

250

11,9

11,4

10,3

8,9

6,8

4,2

13,3

12,4

10,9

6,3

15,5

14,5

13

11,2

9,1

6,2

15,8

14,7

13,3

11,4

9,3

6,4

m3/h

15

18

21

24

27

30

34

40

l/min

50

150

250

300

350

400

450

500

567

667

11

10,5

9,5

13,5 12,5 11,5

11

10,5

9,5

8,5

7,5

Q
A

MPC 51

4,7

2,7

MPC 61

6,2

3,6

kW

kW

HP

MPCM 51

1,6

1,1

1,5

MPCM 61

9,2

1,5

2,5

1,8

2,5

2,2

MPCM 71/A 11,2


MPC 71/A

9,15

5,3

P1 Max. power input.

P2 Rated motor power output.

Self-Priming Capability
15

11,5

L=5m 4 3

16,4 15,9 14,9

14

13,4 12,7 12,1

18,2

16

15,5 14,5

18

17

11,3 10,2

14

13

12

8,5

5,8

10,5

Tolerances in accordance with UNI EN ISO 9906:2012

H Total head in m.

with the pump located above the water level

15

14

L=5m 4

15

15

L=7m

L=7m

6
0

MPC 11

MPC 21

MPC 31

MPC 41

4
3

10

10

10

t
min

t
min

t
min

10

t
min

2
1

5
0

(1)

(1)

(1)

0
0

2
Hs m

15

0
0

2
Hs m

15

MPC 51

2
Hs m

0
0

2
Hs m

L=7m
6

MPC 71

three-phase only

15

MPC 61

10

L=7m 6 5

L =7m

0
0

72.859/1

(1)

10

10

t
min

t
min

t
min

3
2
1

(1)

(1)

(1)

2
Hs m

2
Hs m

72.906

(1)

2
Hs m

L
L

Application limit for automatic self-repriming at each start-up, without


check valve.

L (m) Horizontal length of suction pipe above the water level.

Hs

Hs (m) Suction lift.

G2
DN 50

t (min) Self-priming time.


3.93.025

162

MPC

Self-Priming Swimming Pool Pumps

Compact Pool

Dimensions and weights


fM
ISO 228

235

215
ISO 228

(2)

128,5

504

332

8,9

MPC 21/A - MPCM 21/A

536

337

10,2 11,3

MPC 31/A - MPCM 31/A

536

337

11,2 12,2

- MPCM 11

MPC MPCM

197
215

(1)

123

fM
MPC 11

243
323
9

kg

3.93.028

(2)

mm

TYPE
TIPO

293

G2

50

G1 1/2

410

13
584
215

ISO 228

235
ISO 228

(2)

(2)

17,5 kg
16,0 kg

w
(1)

123

128,5

197
215

410

600

323

MPCM 41
MPC 41

3.93.072

243

293

G2

50

G1 1/2

(640 MPC(M) 71/A)

235
215

ISO 228

(2)

(2)

14
30

188

14

260

72

(1)

220
250

520

(1) Base-plate kit

323

21

4.93.170

243

323

G2

80

ISO 228

G2

(2) Draining

163

MPCM
MPC
MPCM
MPC
MPCM
MPC

51
51
61
61
71/A
71/A

18,9
17,4
20,7
19,6
23,8
22,5

kg
kg
kg
kg
kg
kg

MPC

Self-Priming Swimming Pool Pumps

Compact Pool
Features

Diffuser with peripheral-longitudinal flow,


for a quicker self-priming

4.93.035

Strong transparent Lexan strainer cover

Strong Noryl pump casing

3.93.102

Large 2-litre capacity strainer basket

Stainless steel AISI 316 wear-ring diffuser-funnel,


for extra reliability

Mechanical seal without contact with the shaft,


for extra safety

164

09/2016

NMP

Self-Priming Centrifugal Pumps


with built-in strainer

Construction
Close-coupled self-priming centrifugal pumps with built-in
strainer.
Inner basket with 3 mm holes.
NMP: version with pump casing and lantern bracket in cast iron,
with cataphoresis coating.
B-NMP: version with pump casing and lanter bracket in bronze
(the pumps are supplied fully painted).

Applications
For water circulation in swimming pool filtration systems.
For clean or slightly dirty water with solids in suspension.

Operating conditions
Liquid temperature up to 60 C.
Ambient temperature up to 40C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 6 bar.
Continuous duty.

14

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
NMP: three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% from 4 to 11 kW;
NMPM: single-phase 230 V 10%, with thermal protector.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 from 7,5 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components
Pump casing
Lantern bracket
Impeller

NMP
B-NMP
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705 for NMP 32/12
Chrome-nickel steel
Cr-Ni-Mo steel
1.4305 EN 10088 (AISI 303) 1.4401 EN 10088 (AISI 316)
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Carbon - Ceramic - FPM

Shaft
Strainer cover
Strainer
Mechanical seal

Special features on request


-

Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP55.
Special mechanical seal
Higher liquid or ambient temperatures.

Coverage chart n 2900 rpm


Imp. g.p.m.

20
25

40

30 U.S. g.p.m.

50

100

50

200

100

200

300
300

400

400

500

40

H
m
100

30

NMP 65/16

H
ft
20
50

NMP 32/12

NMP 50/12

10

Q
100

m3/h
l/min

10

20
200

300

30
400

40

500

50

100
1000

1500

0
120
2000

72 891 C

165

NMP

Self-Priming Centrifugal Pumps


with built-in strainer

Performance n 2900 rpm


3~

1~

230V 400V

B-NMP 32/12FE

3,3

1,9

B-NMP 32/12DE

3,3

1,9

B-NMP 32/12AE

4,7

2,7

B-NMP 32/12SE
B-NMP 50/12HE
B-NMP 50/12GE
B-NMP 50/12F/A
B-NMP 50/12D/A
B-NMP 65/16F/A
B-NMP 65/16E/A
B-NMP 65/16D/A
B-NMP 65/16C/B
B-NMP 65/16A/B

7,5
4,7
7,5
9,15
11,5

230V

A
B-NMPM 32/12FE

4,5

B-NMPM 32/12DE

5,8

B-NMPM 32/12AE
4,3 B-NMPM 32/12SE
2,7 B-NMPM 50/12HE
4,3 B-NMPM 50/12GE
5,3
6,6
9,6
10,8
14,3
18,5
21,5

7,4
9,2
7,4
9,2

P1
kW

9,6 10,8 12 13,2 15 18,9 21

24

160
12
11
17
16
21
20,5
21,5

400 500 700 800 900 1000 1100 1250 1400 1600 1800

m3/h 6,6

P2
kW HP

l/min 110
13
0,55 0,75
12
0,8 0,55 0,75
18
0,75 1
17
1,3 0,75 1
22
1,1 1,5
21,5
1,85 1,1 1,5
22,5
2 1,5
2
1,85 1,1 1,5
H
2 1,5
2
m
2,2
3
3
4
4
5,5
5,5 7,5
7,5 10
9,2 12,5
11 15

P1 Maximum power input.

B-NMP = Bronze construction.

P2 Rated motor power output.

H Total head in m.

180
11
10
16
15
20,5
19,5
21

200
10,5
9,5
15,5
14,5
20
19
20,5

220
10
9
15
14
19,5
18,5
20

250 315 350


9
8
14
13
18,5
17,5
19 16* 15*
9
9
12 12
16 16
18 18

12*
8,5
11,5
15,5
17,5

30

7,5
10,5
14,5
16,5
18
20,5
26
29,5
37,5

42

5,5
8
12
15
17
19,5
25
28,5
36,5

48

4,5
7
10,5
13
16,5
19
24,5
28
36

54

3
5
8,5
11,5
15,5
18
24
27,5
35,5

60

3,5*
6,5*
9,5*
14,5
17
23
27
35

66

5*
7*
13,5
16
22
26,5
34

75

84

11,5
14,5
21
25
32,5

9,5
12,5
19
23,5
30,5

96 108

6,5*
9,5*
16* 11*
20* 16*
27* 22*

* Maximum suction lift 2-3 m.


Tolerances according to UNI EN ISO 9906:2012

Dimensions and weights

fM
l1

l2

DN2

DN1

h2

h5
h1

H
g1
4.93.067

m2
m1

n3

b
n2
n1

w
mm

DN1 DN2
TIPO
TYPE

n3

G 2 G 2 195 510 230 50 228 320 100 70 190 140 30

50

ISO 228

E
B-NMP 32/12AE-DE-FE
B-NMP 32/12SE
B-NMP 50/12GE-HE
B-NMP 50/12F/A
B-NMP 50/12D/A
B-NMP 65/16F/A
B-NMP 65/16D/A-E/A
B-NMP 65/16C/B
B-NMP 65/16A/B

fM

h1

h2

h5 m1 m2 n1

n2

540
240
37
G 21/2 G 21/2 205 580 262 60 240 360 100 70 240 190 37
602
250
20
717
298
60
748
320
49
G 3 G 3 320
360 80
470 125 95 280 212
858
345
43
908
345
43

166

NMP
kg

B-NMP
kg

B-NMP 32/12FE
B-NMP 32/12DE
B-NMP 32/12AE
B-NMP 32/12SE

30
30
31
33

32
32
33
35

B-NMP 50/12HE
B-NMP 50/12GE
B-NMP 50/12F/A
B-NMP 50/12D/A

37
38,5
41,5
50,5

39
40
44,5
54,5

B-NMP 65/16F/A
B-NMP 65/16E/A
B-NMP 65/16D/A
B-NMP 65/16C/B
B-NMP 65/16A/B

79
92
97,5
121
127

89,5
102
107,5
130
137

TYPE
TIPO

50

65

l1

l2

g1

14 106 99 220 12
234
14 120 117 274 12
298
298
319
14 165 164
15
408
458

NMP

Self-Priming Centrifugal Pumps


with built-in strainer

Characteristic curves n 2900 rpm


0 U.S. g.p.m. 20

40

60

80

100

S 130

0 U.S. g.p.m.

200
60

65%

60

64

F 103

Hm

H ft

50

15

50
60

40
55

H 100

10

60

64
62

G 107

60

300

NMP 50/12

62

15

64

D 118

52 55

F 120

70

20

100

D 125

NMP 32/12

60

A 130

Hm

20

80

52

30

H ft

25

40
20
10

66

30

67%

10
20

l/s

l/min

10
150

100
1

200
3

15
250

20
300

350

A
D

1.5
1.0

P kW

0.8

600
8

10

12

60
1000

14

16

70

18

25

25

20

20

10
0

40

NPSH m

15

Q m3/h

10

0 U.S. g.p.m. 100

15

200

A 174.5

300

55 58
60

72.063

20

400

120

63%

C 158

62

100
60

D 148

58
55

80

E 136
F 130

20

60

H ft

30

40
10
20

0
0
0

3
Q m /h 20

40

l/min

500

l/s 4

12

60
1000
16

80

0
120
2000

100
1500

20

24

28

32

A
10

15

C
D
E
F

10

P HP

10

30
20

10

2
0

Q m3/h 20

40

60

80

100

72.062

120

NPSH ft

8
6

10
0

500

NMP 65/16

62

25

15

4
2

5
0

14

NPSH ft

NPSH m

50
800

Hm

400
6

40

0.5

P kW

30

0.4

NPSH m

l/s 2

20

S 2.0

1.2

3
0
Q m /h 10
0
l/min 200

1.6

P kW

25
400

P HP

Q m /h

167

5
0 Q m3/h 10

20

30

40

50

60

72.061

70

NPSH ft

0
0

P HP

NMP

Self-Priming Centrifugal Pumps


with built-in strainer

Features

3.94.082

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NMP seies pumps to be selected for use with different types of liquids.

Stainless steel filter


A large capacity Stainless steel filter is fitted which is easy to remove for
inspection and cleaning.

Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection to the end user whilst allowing for inspection of the mechanical seal.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability under all operating conditions.

168

09/2016

PF

Pre-filters in stainless steel

Construction
Pre-filters with removable basket, constructed in stainless steel.
Loose ring flange connections.
Clamp type closing with lever and double adjustment clamp.
Inner basket with 6 mm holes.

Applications
For water circulation pump in filtration plants in swimming
pools.
To prevent foreign bodies from entering the pump and the
plant.

Operating conditions
Max working pressure: 3 bar.
Max flow: 180 m3/h for PF 100.
240 m3/h for PF 125.
300 m3/h for PF 150.

Materials
Components
Pre-filter body PF
PF
PF
Pre-filter body PF
PF
PF
Strainer basket

Diagram of head loss

Materials
100-304
125-304
150-304
100-316
125-316
150-316

Stainless steel AISI 304

Stainless steel AISI 316


Stainless steel AISI 316

Dimensions and weights


D

(1)

PF 100

PF 125

PF 150

DN

DN

h2

h1
4.93.206.1

(2)

FlangesUNI
UNI6089
6089PN
PN10
10
Flange
mm

Type
Tipo

DN

Q m /h
3

50

100

150

200

250

PF 100

100

PF 125

125

PF 150

150

h1

h2

530

247

287

550

260

300

440

292

185

17,5

440

292

185

17,7

500

350

210

23,3

300

H = Head loss in meters

1 Relief valve

169

kg

2 Draining plug

15

PF

Pre-filters in stainless steel

Recomended pumps and pre-filters

Pump
Bronze

Cast iron
NM 80/16E/B
NM 80/16D/C
NM 80/16C/C
NM 80/16B/C
NM 80/16A/C
NM4 80/20A/A
NM4 100/20B/A
NM4 100/20A/A
NM4 100/25B/A
NM4 100/25A/A
NM4 125/25C/A
NM4 125/250B/A
NM4 125/250A/A

B-NM 80/160E/B
B-NM 80/160D/C
B-NM 80/160C/C
B-NM 80/160B/C
B-NM 80/160A/C
B-N4 80/200A/A
B-N4 100/200B/A
B-N4 100/200A/A
B-N4 100/250B/A
B-N4 100/250A/A
B-N4 125/250C/A
B-N4 125/250B/A
B-N4 125/250A/A

kW

HP

7,5
9,2
11
15
18,5
4
4
7,5
5,5
9,2
11
9,2
15

10
12,5
15
20
25
5,5
5,5
10
7,5
12,5
15
12,5
20

Q m3/h

Pre-filter
type

PF 100

PF 100
PF 125
PF 125
PF 150

Hm

min

max

min

max

75
75
75
75
75
30
48
48
48
48
84
84
84

168
168
180
192
192
120
168
192
210
210
300
330
330

10,6
14,4
16,4
22,4
28,1
6
4,5
6
5,5
8,9
5,8
8,2
9,3

21,5
25,2
28,7
34,8
39,9
13,9
15,2
22,3
12
19,5
16,7
19,3
22,7

Examples of installations
Operation with positive suction head

Operation with suction lift

4.93.205.1

4.93.205.2

1 Gate valve

2 Pressure gauge

3 Check valve

4 Foot valve

170

09/2016

Self-Priming Centrifugal Pumps


with open impeller

Construction
Close-coupled centrifugal pumps with open impeller.
The built-in backflow preventer avoids reverse siphoning when the
pump is stopped and assures automatic re-priming at the next start.
The pump re-primes itself even if partially filled with liquid and
with completely empty suction pipe.
A: version with pump casing and lantern bracket in cast iron.
B-A: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).

Applications
For clean or slightly dirty water, also with solids up to 10 mm
grain size for A 40, A 50 and 15 mm for A 65, A 80.
For draining a basin or a sump.
For irrigation. For civil and industrial applications.

Operating conditions
Liquid temperature from -10 C to +90 C.
Room temperature up to 40 C.
Maximum permissible working pressure up to 6 bar (10 bar for
A 80-170).
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
A three-phase
230/400 V 10% up to 3 kW;
400/690 V 10% from 4 to 7,5 kW;
AM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 for 7,5 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components
Pump casing
Suction flange
Inspection cover
(for A 65, A 80)

Lantern bracket
Impeller
Shaft

B-A

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Special features on request


Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP 55.
Special mechanical seal.
Higher or lower liquid or ambient temperatures.
Construction with bearing bracket.

Chrome-nickel steel
1.4305 EN 10088 (AISI 303)

Mechanical seal

Cr-Ni-Mo steel
Chrome steel 1.4104 EN 10088 1.4401 EN 10088 (AISI 316)
(AISI 430) for A 65-150A,B
Carbon - Ceramic - NBR

Coverage chart n 2900 rpm


0 U.S. g.p.m.

50

100

150

200

250

300

40
120

100

30

H
H

ft

A 80-170

20

80

A 65-150

60

40

A 50-125

10

A 40-110

0
m 3/h
0 Q l/min

10
200

20

20
300

400

30
500

40
600

700

50
800

900

60
1000

70
1100
72.855

171

16

Self-Priming Centrifugal Pumps


with open impeller

Performance n 2900 rpm


3~

230 V 400 V

A 40-110B/A
B-A 40-110B/A
A 40-110A/A
B-A 40-110A/A
3~

2,8

1,6

3,7

1~

AM 40-110B/A
B-AM 40-110B/A
AM 40-110A/A
B-AM 40-110A/A

2,2

230 V 400 V
A

A 50-125CE
B-A 50-125CE
A 50-125BE
B-A 50-125BE
A 50-125AE
B-A 50-125AE
3~

230 V

1,9

4,7

2,7

7,5

4,3

kW

4,5

0,85

P2
kW

HP

3~

l/min

1~

1,1

230 V

P1

kW

kW

HP

5,8

1,2

0,75

7,4

1,6

1,1

1,5

9,2

2,1

1,5

AM 50-125CE
B-AM 50-125CE
AM 50-125BE
B-AM 50-125BE
AM 50-125AE
B-AM 50-125AE

0,75

P2

4,8

60

80

7,5

8,4

9,6

10,8

12

15

18

100

125

140

160

180

200

250

300

12,9 12,4

11,8

11

10,4

9,8

8,3

3,4

15,4 14,9

14,2

8,4

5,6

P2

kW

HP

6,6
5,3

2,2

11,5

6,6

9,6

5,5

230 V 400 V

13,3 12,9 12,1

12

15

18

21

24

27

30

33

l/min

100

150

200

250

300

350

400

450

500

550

10

8,5

5,3

3,3

15,5 14,9 14,2 12,9 11,6

10

8,3

6,2

19,5

19

18

17

15,5

14

m3/h

15

18

24

30

33

36

42

l/min

250

300

400

500

550

600

17,5

17

16

14

13

11,5

21,5

21

19,5

29

28

27

15

18

21

250

300

350

27,3 27,3

27

Hm

P2

kW

HP

10,9

5,5

7,5

11,3 10,5

m3/h

Hm

A 80-170A/A
B-A 80-170A/A
P1 Maximum power input.

3,6

12,8 12,2 11,3

11,5
9,15

A 80-170B/A
B-A 80-170B/A

m3/h

0,55 0,75

230 V 400 V

A 65-150C/B
B-A 65-150C/A
A 65-150B/B
B-A 65-150B/A
A 65-150A/B
B-A 65-150A/A

Hm

3,3

P1

m3/h
l/min

12,5 10,5

48

54

57

700

800

900

950

6,5

17,5 16,5 15,5 12,5


25,5 24,5

9,5

6,5

23,5

21

18

14

11

60

66

24

30

36

45

54

400

500

600

750

900

1000 1100

26,8 25,7 24,4 22,1

19

16,7 13,7

Hm
7,5

14,3
P2 Rated motor power output.

H Total head in m.

10

33,6 33,2 32,9 32,5 31,6 30,5 28,1 25,3 23,2 20,4

B-A, B-AM = Bronze construction.

Tolerances according to UNI EN ISO 9906:2012

Self-priming capability
Tubo
DN 40
mm
withaspirante
DN 40 mm
suction
pipe

20

Tubo
DN 50
mm pipe
withaspirante
DN 50 mm
suction

Tubo
DN 65
mm
withaspirante
DN 65 mm
suction
pipe
15

20

A 40-110

A 50-125

=1m

L= 1 m

min

10

B
A

A 80-170

t
min

min

10

min

L= 1 m

L= 1 m

Tubo
DN 80
mm pipe
with aspirante
DN 80 mm
suction
10

A 65-150

10

B
5

Hs

4
m

0
0

Hs

4
m

Hs

Hs

4
m

0,5 m

Hs
3.93.021.2

Hs (m) Suction lift.


Hs (m)
Altezza dilength
aspirazione.
L (m)
Horizontal
of suction pipe above the water level.
L (m)
Lunghezza del
tubo aspirante orizzontale sopra il livello dell'acqua.
t (min)
Self-priming
time.

(min) Tempo di autoadescamento.


Risultati di collaudo con acqua fredda

172

Self-Priming Centrifugal Pumps


with open impeller

Characteristic curves n 2900 rpm


80

24

A 40-110

18

14

B 115
40

10
100

15

20

200

P kW

0,6

50

1,0

0,4

30

10
0

40

54

300

0,8

50
56

0,5

P HP

1,0

61%
58

20

10

2
3
Q m /h
l/min

60

10

20

0
0

3
Q m /h 5

l/s 1

10

15

l/min 100
2

200
3

20

25
400

300
4

30
500

35

2.5

P kW

40

2.0

1.5

1.0

0.5

20

20

4
10

2
0

NPSH ft

NPSH m

0
8

0
3

Q m /h

10

0 U.S. g.p.m. 50

100

15

150

200

A 150

30

50

20
15

10
5
0

Q m3/h 5

15

100

20

150

25

200

30

72.370

250

35

300
120

A 80-170

100

B 153

80
59

10

A 165

100
30

C 126

Hm

25

40

61%

B 133
20

0 U.S. g.p.m.50

250

A 65-150

55 57
59

20

80
57

55

60

50

Hm

H ft

(%)

60

0,2

NPSH m

70

58

C 107

Hm

30

15

H ft

Hm

10

150

A 50-125
50 54
56

B 105

100

A 124

20
50

12

50

60

A 113

16

0 U.S. g.p.m.

H ft

60

P HP

40

NPSH ft

20

20

60

H ft

0 U.S. g.p.m.
20

40

40

10

10

20
20
0

l/min

l/s 2

10
200

20
300
400
4

30
500

600

10

40
700
12

50
800
900
14

60
1000
16

6
5
4

2
1

20

4
10

2
0

NPSH m

30

NPSH ft

NPSH m

10

Q m3/h

20

40

72.371

400

600

50
800

60

70

1000

10
8
6

A
B

40
20
0
10

30

8
6

20

4
10

2
0

0
0

200

40

30

60

(%)

P HP

P kW

l/min

20

P HP

Q m /h

3
Q m /h 10

0
0

60

173

3
Q m /h 10

20

30

40

50

60

70

NPSH ft

0
0

P kW

16

Self-Priming Centrifugal Pumps


with open impeller

Dimensions and weights


393
132
83

G 1 1/2

89

kg

G 1 1/2

208

ISO 228

ISO 228

275
206

16

70
100

A 40-110A/A
AM 40-110A/A

19,8
20,8

A 40-110B/A
AM 40-110B/A

18,9
19,8

B-A 40-110A/A
B-AM 40-110A/A

22,5
23,5

B-A 40-110B/A
B-AM 40-110B/A

21,6
22,5

50
140
190

199

490
102

96

147

kg

G2

G2

231

ISO 228

ISO 228

295
223
14
4.93.103

30

16

70
100

50

140
263

190

A 50-125AE
AM 50-125AE

29,9
31

A 50-125BE
AM 50-125BE

28
29,1

A 50-125CE
AM 50-125CE

26,9
27,8

B-A 50-125AE
B-AM 50-125AE

33,6
33,6

B-A 50-125BE
B-AM 50-125BE

31
32,6

B-A 50-125CE
B-AM 50-125CE

29,6
30,6

fM
172

115

121

G 2 1/2
ISO 228

mm
TIPO

kg

G 2 1/2

293

ISO 228

TYPE

368
H
14
4.93.102

47

16

95
125

fM

A 65-150C/B
B-A 65-150C/A

595
583

270
260

324
319

56,7
50,4

A 65-150B/B
B-A 65-150B/A

595

270

324

57
58,5

A 65-150A/B
B-A 65-150A/A

595

270

324

58,5
60

50

190
w

240

659
202
132

G3

140

ISO 228

G3
342

ISO 228

kg
A 80-170A/A

85,8

A 80-170B/A

80,3

B-A 80-170A/A

95,6

B-A 80-170B/A

90,1

427
317

17

110
145

22
352

47
220
280

174

60

Self-Priming Centrifugal Pumps


with open impeller

Dimensions and weights

172

102

116

G2

96

50

24 k6

27

293

16
50
140
190

70
100

132

4.93.124.1

14

100

27

231

295

50

24 k6
16

95
125

202

50

190
289

594

123

14

G2

386
G 2 1/2

G 2 1/2

275

145

AS 65-150A/A-B/A-C/A
B-AS 65-150A-B-C

558

368

AS 50-125A-B-C
B-AS 50-125A-B-C

420

240

AS 80-170A-B
B-AS 80-170A-B

392
G3

132

140

G3

16
50

427

24 k6

17

160

27

342

110

22

145

60

220
295

281

Pumps with motor


FM
a

h3

DN 1

h2

DN 2

w1

m5

g2

s1
w1

n5

a1
m4

POMPA
PUMP
B-AS B-AS B-AS B-AS B-AS B-AS -

AS 50-125C
AS 50-125B
AS 50-125A
AS 65-150C/A
AS 65-150B/A
AS 65-150A/A
AS 80-170B/A
AS 80-170A/A

MOTORE
MOTOR
80 M2
80 M2
90 S2
90 L2
100 L2
112 M2
132 S2
132 S2

n4

mm
kW
0,75
1,1
1,5
2,2
3
4
5,5
7,5

DN1
G2

DN2
G2

G 2 1/2 G 2 1/2
G3

G3

h3

h2

m4

m5

w1

n4

n5

a1

g2

s1

145

275

306

64

625

595

15

140

200

100

75

14

172

386

378

93

780
880
880

750
850
850

15

190

240

90

85

14

202

392

442

85

880

850

15

240

300

100

100

14

175

FM
716
716
771
909
958
951
1073
1073

Self-Priming Centrifugal Pumps


with open impeller

Features

1.94.032

Fast self priming


An integrated non-return valve and the design of the pump casing ensures rapid
priming, once the pump body has been filled with water.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows A series pumps to be selected for
use with different types of liquids.

Solid parts
The open impeller allows for the passage of suspended solids in pumped liquid.

Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection to the end user whilst allowing for inspection of the mechanical seal.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability under all operating conditions.

176

09/2016

Centrifugal Pumps
with open impeller

Construction
Close-coupled centrifugal pumps with open impeller.
Free-flow impeller (vortex or recessed impeller) for type C 16/1E.
C: version with pump casing and lantern bracket in cast iron.
B-C: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).

Applications
For moderately dirty liquids or emulsions.
For industry and agriculture.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 8 m.
Maximum permissible working pressure: 6 bar.
Maximum size of solids: 4 mm.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
C: three-phase 230/400 V 10%.
CM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component
Pump casing
Lantern bracket
Impeller
Shaft

Mechanical seal

C
B-C
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705
Chrome steel
1.4104 EN 10088 (AISI 430)
Cr-Ni-Mo steel
Chrome-nickel steel
1.4401 EN 10088
1.4305 EN 10088 (AISI 303)
(AISI 316)
for C 41
Carbon - Ceramic - NBR

Special features on request


-

Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP55.
Special mechanical seal
Higher or lower liquid or ambient temperatures.
Motor suitable operation with frequency converter.
Construction with bearing bracket.

Coverage chart n 2900 rpm


2 Imp. g.p.m.

U.S. g.p.m. 4

8
8

10

20

10

30

20

30

40
40

50

60

50

60 70

30

80

C 41E

C 22E

20

ft

C 4/A

C 22/1E

60

C 4/1/A
C 20E

40

10

C 16/1E

0
0.5
10

m3/h
Q l/min

20

2
20

30

40

3
50

15

10
100

200

0
18
300

72 892 C

177

17

Centrifugal Pumps
with open impeller

Performance n 2900 rpm


Q
3~

1~

230V 400V
A

C 16/1E
B- C 16/1E
C 20E
B- C 20/A
C 22/1E
B- C 22/1/A
C 22E
B- C 22/A
C 4/1/A

P1

kW

kW

HP

1,2

0,16

0,15

0,2

0,4

0,37

0,5

0,8

0,45

0,6

0,9

0,55

0,75

A
CM 16/1E
B- CM 16/1E

1,7

1,9
2,3
2,4
2,3

1,1
1,3
1,4
1,3

1,7

P2

230V

2,5
2,8
3
3,6
3,5
4,5

CM 20E
B- CM 20/A
CM 22/1E
B- CM 22/1/A
CM 22E
B- CM 22/A

1,7

CM 4/1/A

4,5

0,91

0,55

0,75

C 4/A
B- C 41/1E

3,7
3,3

2,2
1,9

CM 4/A
B- CM 41/1E

5,7
5,8

1,2

0,75

C 41E
B- C 41E

4,7

2,7

CM 41E
B- CM 41E

7,4

1,6

1,1

1,5

m3/h

0,6

0,9

1,2

1,5

1,8

2,4

3,6

4,8

l/min

10

15

20

25

30

40

50

60

80

4,7

4,4

4,2

3,6

12,3 12,2 12 11,5 10,8


18

H
m

18 17,5 17

20,5 20

20

6,6

8,4

9,6 10,8 12 13,2 15

100 110 140 160 180 200 220 250

16

14

10

7,5

19 18,5 16,5 14

12

15,6 15,4 15,2 15

14 13,1 12 10,8 9,5

19 18,8 18,5 18,3 17,7 17,4 16,8 16

15

7
13

22,4 22,3 22,2 21,5 21 20,5 19,5 18 15,5

P1 Maximum power input.

B-C, B-CM = Bronze construction.

= Density 1000 kg/m .

P2 Rated motor power output.

H Total head in m.

= Kinematic viscosity max 20 mm2/sec.

Tolerances according to UNI EN ISO 9906:2012

Dimensions and weights


263

266
34

33
122

G 1/2

l1

l2
l3

G1
ISO 228

G1

75

ISO 228

G 1/2

ISO 228

ISO 228

h2

160

160
8 63
4.93.222

7
93

8 63

h4

4.93.221

22

80

100

96

122

7
88

TYPE

kg

TYPE

kg

C 16/1E
CM 16/1E

5,2
5,2

B-C 16/1E
B-CM 16/1E

5,6
5,6

22

80
96

TYPE

100
122

h2
90
110

C 20E
C 22/1E - C 22E

mm
l1
67
77

h4
5
17

kg
l2
82
94

l3
60
71

C
6,8
8 - 8,3

CM
6,8
8 - 8,3

fM
a

l1

l2
l3

DN 1

DN 2

h2
H
HA h1

h4
K
B
BB

DN1

4_93_223

AA
A
AB
mm

DN2

kg

TIPO
TYPE
ISO 228

B-C 20/A

C 4/1/A
C 4/A

C 41E

B-C 22/1/A
B-C 22/A

B-C 41/1E
B-C 41E

fM

h1

h2

h4

BB

AB

AA

l1

l2

l3

HA

CM

G1

G1

35

303

71

90

182

106

90

134 112

22

70

84

60

105

10

G1

G1

35

303

71

110 182

106

90

134 112

22

81

93

71

106

10

G 11/2 G 11/2 43

304

71

160 182

18

106

90

134 112

22

85

108

78

100

10

G 11/2 G 11/2 43

380

80

160 208

125 100 155 125

30

9,5

85

108

78

132

10

10,8
11,8
18,5

11,8
12,8
19,3

178

B-C B-CM
9,1

9,1

9,3
9,6
16,3
19,2

10,3
10,6
17,9
20,1

Centrifugal Pumps
with open impeller

Characteristic curves n 2900 rpm


6

0 U.S. g.p.m. 2

10

11

15

0 U.S. g.p.m.

10

15

20

19

17

13

20

C 20E

14

18

64

28

Hm

15

H ft

Hm

25

30

50

40
54
56%
35

13

31%

45

12
11

14

40

95.5

16

45

H ft

C 16/1E

54

10

12

10
3

0
0

Q m /h

l/s

0.5

1.5

10

l/min
0.1

20
0.2

30

0.3

0.4

2.5
40

0.5

0.6

0.1

0
0

Q m /h

l/s

2
20

l/min
0.2

30

40

0.4

0.6

3
50
0.8

4
60

5
70

80

1.2

P kW

0.3

P HP

P kW

0.1

0.05

0.4
0.3

0.2

0.2

P HP

30

11

0.1
0.1

Q m /h

0.5

1.5

0
2.5

72.126

3
2
1
0

25

0 U.S. g.p.m.

10

20

30
80

C 22 119.5

35

20

40

44

C 22/1 116

C 22E
C 22/1E
46

70

47

60
44

15

50
40

H ft

Hm

46

35

49%

40

10

30
20
0
0
0

Q m /h 1
l/min 20
l/s

3
40

4
60

0.5

6
100

80

1.5

1.9

0.7

0.9
0.8

C 22

0.7

0.5

C 22/1

0.6

0.4

0.5

0.3

0.4

0.2

0.3

NPSH m

4
3
2
1
0

P HP

P kW

0.6

Q m3/h 1

72.123

12
10
8
6
4
2
0

NPSH ft

179

17

NPSH m

Q m3/h

72.121

12
10
8
6
4
2
0

NPSH ft

Centrifugal Pumps
with open impeller

Characteristic curves n 2900 rpm


0 U.S. g.p.m.

20

30

40

50

60

0 U.S. g.p.m.

70

20

30

40

50

60

70
70

70

C 4/1/A

20

20

117

55 60

60

65

60

70
72%

Hm

50

15

65

50

70

H ft

65%

Hm

55 60

15

H ft

108

C 4/A

40

40
60
10

10

30

30

55

20

20
0
0

Q m /h

l/s

l/min

10

50

100
1

150

15
250

200

300

l/s

5
50

10
100

150

15
250

200

300

1.0
1.2

0.8

0.4

0.6

P kW

0.8

P HP

0.6

1.2

0.8

1.0

1.0

0.6

0.8

0.4

0.6

0.4

0.4
0.2

0.2

25

25

20

20

15

10
0

25

NPSH m

2
0

Q m3/h

0 U.S. g.p.m.

10

20

30

72.124.1

15

40

50

60

70

C 41E

54
58

70

59.5%

Hm

60

H ft

20
58

50

15

40

0
0

Q m /h

l/s

10
100

l/min
1

15
260

200
2

1.2

1.6

1.0

1.4
1.2

0.8

1.0

0.6

P HP

P kW

10

0.8
0.6

0.4

15
10

2
0

NPSH ft

6
4

5
0

Q m3/h

10

72.125

15

10
0

80
50

40

15

4
2

124

NPSH m

0.2

NPSH ft

NPSH m

0.2

P HP

1.0

P kW

3
0
Q m /h
0
l/min

180

5
0 Q m3/h

10

15

72.124.2

NPSH ft

Centrifugal Pumps
with open impeller

Features

17
3.94.058

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows C series pumps to be selected for
use with different types of liquids.

Solid parts
The open impeller allows for the passage of suspended solids in pumped liquid.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability under all operating conditions.

181

182

09/2016

CT 61

Peripheral Pump
Construction
Close-coupled peripheral pump (regenerative pump) with
turbine impeller. Compact, patented construction with singlepiece motor casing and pump-side wall.
Protected against water entering the motor from outside.
CT: version with pump casing in cast iron.
B-CT: version with pump casing in bronze
(the pumps are supplied fully painted).

Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable
to be mounted in cooling and air-conditioning machines and
equipments, circulation.

Operating conditions
Liquid temperature up to 60 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Continuous duty.

Motor
Materials
Components

CT 61

B-CT 61

Pump casing

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Casing cover motor side

Brass P- Cu Zn Pb 2 UNI 5705

Impeller

Brass P- Cu Zn Pb 2 UNI 5705

Shaft

Chrome steel 1.4104 EN 10088 (AISI 430)

Mechanical seal

Carbon - Ceramic - NBR

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Special mechanical seal.

Coverage chart n 2900 rpm


0 Imp. g.p.m. 2
44

0 U.S. g.p.m. 2

8
8

10
140

CTM 61
CT 61

40

120

30

100

H
ft

m
20

60
40

10
20
0

0
0

m 3/h
Q l/min

1
10

2
20

30

2.6

2-pole induction motor, 50 Hz (n 2900 rpm).


CT 61:
three-phase 230/400 V 10%.
CTM 61: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

40
72.865

183

18

CT 61

Peripheral Pump

Performance n 2900 rpm


3~
CT 61
B-CT 61

230V 400V 1~
A
A
1,9

CTM 61
B-CTM 61

1,1

Q
m3/h
l/min

230V
A

P2
kW HP

2,5

0,33 0,45 H m

0,48
8
41

0,6
10

0,75 0,96
12,5 16

38,5 35,5

31

1,2
20

1,5
25

1,89
31,5

2,3
38

25,5

19

11

P2 Rated motor power output.

H Total head in m.

198

58

22,5

G1 ISO 228

63

108

158

90

G1 ISO 228

Dimensions and weights

4.93.159

22

100

80

122

96

Features

Patented

4.94.160

184

40.5

CT 61 4,9 kg
CTM 61 5 kg
B-CT 61
5,1 kg
B-CTM 61 5,2 kg

CT 60

Peripheral Pump
Construction
Close-coupled peripheral pump (regenerative pump) with
turbine impeller.
Compact, patented construction with single-piece motor casing
and pump-side wall.
Protected against water entering the motor from outside.

Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable
to be mounted in cooling and air-conditioning machines and
equipments, circulation.

Operating conditions
Liquid temperature up to 60 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
CT 60:
three-phase 230/400 V 10%.
CTM 60: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Components

Materials

Pump casing

Cast iron GJL 200 EN 1561

Casing cover motor side

Brass P- Cu Zn Pb 2 UNI 5705

Impeller

Brass P- Cu Zn Pb 2 UNI 5705

Shaft

Chrome steel 1.4104 EN 10088 (AISI 430)

Special features on request

Mechanical seal

Carbon - Ceramic - NBR

- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Special mechanical seal.

Coverage chart n 2900 rpm


0 Imp. g.p.m. 2
44

0 U.S. g.p.m. 2

8
8

10
140

CTM 60
CT 60

40

120

30

100

H
ft

m
20

60
40

10
20
0

0
0

m 3/h
Q l/min

1
10

2
20

30

2.6

40
72.865_12

185

18

CT 60

Peripheral Pump

Performance n 2900 rpm


3~

230V 400V 1~
A
A
CT 60

1,9

H Total head in m.

1,1

Q
m3/h
l/min

230V
A

P2
kW HP

2,5

0,33 0,45 H m

CTM 60

0,48
8
41

0,6
10

0,75 0,96
12,5 16

38,5 35,5

31

1,2
20

1,5
25

1,89
31,5

2,3
38

25,5

19

11

P2 Rated motor power output.

Dimensions and weights


20
218

ISO 228

63

158

75

G1

ISO 228

G1

CT 60 4,9 kg
CTM 60 5 kg

4.93.528

22

100

80

122

96

Features

Patented

4.93.529

186

40.5 42

09/2016

T, TP

Peripheral Pumps
Construction
Close-coupled peripheral pumps (regenerative pumps) with
turbine impeller.
T, TP: version with pump casing and lantern bracket in cast iron.
B-T, B-TP: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).

Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable
to be mounted in cooling and air-conditioning machines and
equipments, circulation, boiler feed.

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Total suction lift up to 7 m.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
T, TP:
three-phase 230/400 V 10% up to 3 kW;
400/690 V 10% from 4 to 7,5 kW;
TM, TPM: single-phase 230 V 10% with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW
to 5,5 kW, IE3 for 7,5 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components
Pump casing
Lantern bracket
Casing cover

T, TP

B-T, B-TP

Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Cast iron
Bronze
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Brass P- Cu Zn Pb 40 2 UNI 5705 for T 61-65-70, B-T 61-70
Brass P- Cu Zn 40 Pb 2 UNI 5705
Bronze G-Cu Sn 10 EN 1982 for T 125, TP 132-132R
Cr-Ni steel AISI 303
T 76, Tp 80-100
Cr-Ni-Mo steel
Chrome steel AISI 430
AISI 316
T 61-65-70-100-125, Tp 78-132-132R
Carbon - Ceramic - NBR

Impeller
Shaft

Mechanical seal

Special features on request


-

Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP55.
Special mechanical seal.
Higher or lower liquid or ambient temperatures.
Construction with bearing bracket.

Coverage chart n 2900 rpm


0 Imp. g.p.m.
0

U.S. g.p.m.

10

15

10

15

20
20

25

TP 132
160
TP 100

500

TP 132R

ft

m
T 125

400

120
T 100

300

TP 80
80

200
40
100

T 76
TP 78
0

0
0

m /h
l/min

T 61
2

20

T 65

T 70

3
40

4
60

5
80

0
6
100
72.853

187

19

T, TP

Peripheral Pumps

Performance n 2900 rpm


3~

1~

230V 400V

A
1,9
2,8
3,7
5,3
11,5

A
1,1
1,6
2,2
3
6,6
9,6
2,3 1,3
4
2,3
9,6 5,5
10,9
14,3

B- T 61E
B- T 65E
B- T 70/A
T 76E
T 100/A
T 125/A
B- TP 78/A
B- TP 80E
TP 100/A
TP 132R/A
TP 132/A

B- TM
B- TM
B- TM
TM

P1

230V

P2

Q
m3/h 0,06 0,12 0,24 0,38 0,48 0,6 0,75 1

A
kW kW
HP l/min 1
2,5 0,55 0,33 0,45
3,5 0,8 0,45 0,6
6
1,3 0,75 1
7,4 1,6 1,1 1,5
3
4
H
4
5,5
m
2,8 0,6 0,37 0,5
75
5,8 1,2 0,75 1
2,2
3
5,5 7,5
7,5 10

61E
65E
70/A
76E

B- TPM 78/A
B- TPM 80E

70

6,3 8
38 36
44
59
70

60

3,6 4,2 4,8 5,4

20
24
33
48
62

50

60

8
22
38
89
110

10
26
82 75 68
90 75* 60*

25 31,5 40
19 12,5 5
29 24 16
43 38 30
58 53 46
103 97
125

70

80

42 35 25 15
85 79 73 61 48 34 20
160 157 151 140 129 115 99 82
145 135 120 110 95

H Total head in m.

B-T, B-TM = Bronze construction.

P1 Maximum power input.


P2 Rated motor power output.

50
90

10 12,5 16
34 31,5 28
42 40 37
57 55 51
68 67 65

1,2 1,5 1,89 2,4

90 100

70
165 143* 120*

* Maximum suction lift 2-3 m.

Dimensions and weights


fM
244

24
G1 ISO 228

l2

58

DN2

DN2
G1

G1
ISO 228

DN1

ISO 228

h2

65
182

160
108

7
80
96

80

4.93.227

h1

8 63
22
100
122

10 71

4.93.218

7
93

T 61E: kg 6,3
B- T 61E: kg 6,5

22

90

112

106

134

DN1 DN2

TYPE
TIPO

mm

T 65E: kg 7,3
B- T 65E: kg 7,5

T 70/A B-T 70/A G 1 G 1


TP 78/A B-TP 78/A G 1/2 G 1/2

kg
T

fM

h2

h1

l2

24
22

278
276

50
24

121
127

63
56

ISO 228

B-T

11,2 11,6
8,2 8,8

fM
a

l2
DN2

DN2

DN1
h2
H
h1

HA HS
K
B
BB

DN1

TIPO
TYPE

4.93.093

AA
A
AB

ISO 228

kg

mm

DN2
a

fM

HS

h2

h1

BB

AB

AA

l2

HA

T, TP

B-TP

T 76E

G 11/4

G 11/4

26

338

80

56

136

208

117

100

155

125

30

80

105

10

18,4

T 100/A

G 11/4

G 11/4

32

410

90

59

161

226

152

125

180

140

40

9,5

95

121

12

32,5

T 125/A

G 11/4

G 11/4

32

470

90

75

170

226

152

125

180

140

40

9,5

90

195

12

39,5

G 3/4

G 3/4

27

332

80

35

135

208

117

100

155

125

30

60

104

10

16,4

16,8

G 3/4

G 3/4

27

387

80

38

142

208

117

100

155

125

30

65

113

10

23,2

14

53,6
58,5

TP 80E

B-TP 80E

TP 100/A

TP 132R/A
TP 132/A

G 11/4

G 11/4

42

485

112

70

202

272

188

180

140

230

190

50

11,5

100

183

T, TP

Peripheral Pumps

Characteristic curves n 2900 rpm


50

0 U.S. g.p.m. 2

0 U.S. g.p.m.

10

12
180

160
50

T 61E
40

160

140

60

T 65E

65

120

140

40
120

80

60

20

60

40
10

40

10
20

Q m /h

l/s

0.5
8

l/min

12

0.1

1
16

0.2

20
0.3

1.5
24
0.4

2
28

32

2.5
36

0.5

40

0.6

0.4

0.2

0.3

30
0.4

40

0.5

0.6

0.7

0.8
0.8
0.6
0.4
0.2

NPSH m

18

5
13

4
3

2
0

0.5

Q m3/h

0 U.S. g.p.m.

60

1.5

12

72.136

2.5

NPSH ft

25

20
15

10
2
0

16

80

5
0

Q m3/h

0 U.S. g.p.m.

200

T 70/A

71

72.137

10

12

14

16

T 76E

76

200

60

50

H ft

Hm

40

H ft

NPSH m

20

0.2

0.2

Hm

10

l/s 0.1

3
50

0.1

70

l/min

0.4

0.2
0.1

P kW

P kW

0.4
0.3

Q m /h

0.6

0.5

0.3

0
0

P HP

0
0

20

P HP

H ft

100

30

NPSH ft

20

H ft

Hm

80

Hm

100

30

40

100

30

100
20

20

10

Q m /h

l/s

l/min 10

2
20

0.2

30

40

0.4

0.6

3
50
0.8

60

0
0

Q m /h

l/s

1.0

20

0.2

30

40

0.4

0.6

3
50
0.8

4
1

1.2

0.6

P kW

0.8

P HP

P kW

1.0

0.4

0.8

0.4
0.2

60

1.2

0.6

0.4

0.2

NPSH m

15

4
10

3
2

1
0

Q m3/h

72.138

4
NPSH ft

NPSH m

l/min 10

1.6

0.8

P HP

0
0

10

3
2

5
1
0

189

Q m3/h

72.139

NPSH ft

19

T, TP

Peripheral Pumps

Characteristic curves n 2900 rpm


0 U.S. g.p.m. 1

1.5

2.5

3.5

4.5

0 U.S. g.p.m.
120

5
320

TP 78/A

8
380

TP 80E

280

80

100
80

240

Hm

160
40

80
H ft

Hm

60

300

80

200

H ft

100

200

60

120
80

20

40
40

0
0
0

3
Q m /h 0.2

l/min

0.4
4

l/s

0.6
10

12

0.1

0.8
14

1
16

1.2
20

18

0.2

100

20

0.3

Q m /h

l/s

0.5

l/min 5

1
10

0.1

15

1.5
25

20

0.2

0.3

2
30

0.4

0.5

1.0
0.6

0.4

0.2

0.3

1.0

P kW

0.4

P HP

P kW

0.3

1.2

0.8

0.5

0.6

0.8

0.4

0.6

0.2
0.1

NPSH m

15

4
10

3
2

200

Q m3/h 0.2

0.4

0 U.S. g.p.m. 2

0.6

0.8

72.145

1.2

16

12

3
8

1
0

10

130
600

TP 100/A

0.2

0.5

Q m3/h

0 U.S. g.p.m. 4

10

12

14

16

18

20

22
400

T 100/A

120

100

72.141

1.5

110
500

150

100

Hm

400

H ft

Hm

100

100

H ft

NPSH ft

NPSH m

0.4
0.2

0.1

P HP

0.5

0
0

NPSH ft

300

90
80

300
70
200
0
0

Q m /h

l/s

0.5

1.5

10

l/min
0.1

20
0.2

0.3

2
30

0.4

60

2.5
40

0.5

0.6

200
0
0

Q m /h

l/s

2
20

l/min
0.2

30

40

0.4

0.6

3
50
0.8

4
60

5
70

80

1.2

4.0

2.5

P kW

3.0

P HP

P kW

3.5
4

5
3

2.0
1.5

P HP

60

2
0

14
4

12
10

5
0

Q m3/h

0.5

1.5

72.142

2.5

8
2

190

Q m3/h

72.140

NPSH ft

10

NPSH m

15

NPSH ft

NPSH m

5
20

T, TP

Peripheral Pumps

Characteristic curves n 2900 rpm


8

12

16

0 U.S. g.p.m.
400

20

20

TP 132/A
TP 132R/A
Hm

H ft
124

1000

300

500

150

30
1300

600

T 125/A

Hm

10

400

H ft

0 U.S. g.p.m. 4
200

200
100

TP 132/A 132

300

500

TP 132R/A 126
100

200

Q m /h

l/s

l/min

2
20

0.2

30

40

0.4

0.6

3
50
0.8

4
60

70

60

5
80

1.2

20
0.4

3
40

0.6

60
0.8

6
100

80

1.2

1.4

1.6

7
1.8
20

P kW

16
P HP

10

12

TP 132/A

TP 132R/A

10

10

20

6
4

NPSH m

30

NPSH ft

P kW

l/min

l/s

NPSH m

3
Q m /h 1

16

200
0
0

Q m3/h

72.143

0
30

8
20

6
4

10

10
0

P HP

0
0

191

Q m3/h 1

72.144

NPSH ft

50

19

T, TP

Peripheral Pumps

Features

Range
The high number of pumps in the range can meet the widest range of services
required by the user.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows T-TP series pumps to be selected
for use with different types of liquids.

Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability under all operating conditions.

Optimized hydraulics
The pump hydraulics are designed to ensure high performance and consistency
of performance.

192

09/2016

CA

Self-Priming Liquid Ring Pumps


Construction
Close-coupled self-priming liquid ring pumps with star impeller.
CA: version with pump casing and lantern bracket in cast iron.
B-CA: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).

Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
If the liquid to be pumped has entrained air or gas or the flow in
the suction pipe is not stable.
For drawing water out of a well.
For increasing network pressure (follow local specifications).

Operating conditions
Liquid temperature from -10 C to +90 C.
Ambient temperature up to 40 C.
Negative suction pressure up to 9 m.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
CA:

CAM: single-phase 230 V 10%, with thermal protector.


Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components
Pump casing
Lantern bracket

CA

B-CA

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Impeller

Brass P- Cu Zn Pb 2 UNI 5705

Shaft

Chrome steel
1.4104 EN 10088
(AISI 430)

Mechanical seal

three-phase 230/400 V 10%.

Special features on request


-

Cr-Ni-Mo steel
1.4401 EN 10088
(AISI 316)

Carbon - Ceramic - NBR

Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP55.
Special mechanical seal
Higher or lower liquid or ambient temperatures.
Construction with bearing bracket.

Coverage chart n 2900 rpm


0.5
0.5

Imp. g.p.m.

US. g.p.m.

10

5
10

60

CA 91/A
H
m
150

CA 90/A

ft

40

CA 80E
100

20

CA 60E
50

0
0.1
2

m3 /h
l/min

0.5
5

1
20

10

30

40

0
3
50
72.863.C

193

20

CA

Self-Priming Liquid Ring Pumps

Performance n 2900 rpm


3~

230 V 400 V
A

CA 60E
B-CA 60E

1,7

CA 80E
B-CA 80/A

1~

230 V

P1

kW

P2
kW

HP

CAM 60E
B-CAM 60E

1,6

0,26 0,15

0,2

2,8
2,3

1,6
1,3

CAM 80E
B-CAM 80/A

3,3
3,6

0,72 0,45

0,6

CA 90/A
B-CA 90/A

1,7

CAM 90/A
B-CAM 90/A

4,5

0,9

0,55 0,75

CA 91/A
B-CA 91/A

3,7

2,2

CAM 91/A
B-CAM 91/A

5,7

1,2

0,75

P2 Rated motor power output.

P1 Maximum power input.

m 3/h 0,12 0,24 0,38 0,48


l/min

0,6

0,75

1,2

1,5

1,89

2,4

6,3

10

12,5

16

20

25

31,5

40

20

18

15,5

13

10,5

6,5

36

35

33,5 31,5

29

26

22

15

H
m

42

41

40

37

34

30

25

17

53

51

48

44

39

34

26,5

17

H Total head in m.

B-CA = Bronze construction.

Dimensions and weights


fM

l2

l3

DN2
DN1
h2

H
h1
HA HS
4.93.217

K
w

TYPE
TIPO

DN1

B-CA 60E

G
G

1/
2
3/
4

G1

BB

AB

DN2

mm
a

fM

HS

h2

h1

3/
4

18
23

256
272

63
63

25
27

103 158
126 158

G1

28

318

71

41

ISO 228

CA 60E CA 80E
CA 90/A
CA 91/A

AA

G
G

1/
2

kg

BB

AB

AA

l2

l3

HA

CA

B-CA

96
96

80
80

122 100
122 100

22
22

7
7

45
55

14
17

103
109

8
8

142 182 106

90

134

22

63

21

128

10

6
7,6
10,8
11,4

6,8
-

112

fM

l2

l3
DN2

DN1
h2

H
h1
HA HS
K
w

DN1

4.93.228

AA

BB

AB

DN2

mm

kg

TYPE
TIPO
ISO 228

B-CA 80/A
B-CA 90/A
B-CA 91/A

3/
4

G1

3/
4

G1

fM

HS

h2

h1

BB

AB

AA

l2

l3

HA

23

307

71

27

134 182 106

90

134

112

22

55

17

122

10

10

10

13,1
13,9

28

318

71

41

142 182 106

194

90

134

112

22

63

21

128

B-CA

CA

Self-Priming Liquid Ring Pumps

Characteristic curves n 2900 rpm


0 U.S. g.p.m.

40

80

CA 60E
20

0 U.S. g.p.m.

8
120

CA 80E

70

59.85

79.6

60

100

30
H ft

Hm

40
10

Hm

50

15

30

80

H ft

25

20
60

20
5
10

40
0
0

Q m /h

l/s

0.2

0.4

l/min

0.6
10

5
0.1

0.8

1.0

10

15
0.2

0.2

0.1

0
0

Q m /h

l/s

0.5

1.5

10

l/min
0.1

20
0.2

0.3

30
0.4

0.5

0.6

0.8

0.5

0.7

P kW

P HP

P kW

0.2

0.6

0.4

0.5

0.1

0.4
0.3

0.2

25

25

20

20

15

10
2
0

50

0.2

Q m3/h

0.4

0 U.S. g.p.m. 2

0.6

72.074

0.8

1.0

NPSH m

NPSH ft

NPSH m

0.3

60

160

CA 90/A
40

10
2

10

15

5
0

0.5

Q m3/h

0 U.S. g.p.m. 2

72.075

1.5

50

10

CA 91/A
140

P HP

NPSH ft

89.7

180
160

89.6
120

140
120
100

30

80

80

20

60

20

60

40
3
0
Q m /h
0
l/min

l/s

0.5

1.5

10
0.1

20
0.2

0.3

2
30

0.4

40
10

2.5
40

0.5

0.6

3
0
Q m /h
0
l/min

1.0

l/s

0.5

1.5

10
0.1

20
0.2

0.3

2.5

30
0.4

40

0.5

0.6

1.0

0.6

0.8

1.2
0.8
0.6

0.6

0.4

1.0

P kW

1.0

P HP

P kW

0.8

0.8
0.6

0.4

0.4

0.4

25

20
15

10

NPSH m

0.2

NPSH ft

NPSH m

0.2
8

25

20
10

1.5

72.076

2.5

195

15

5
0.5

0.2

2
0 Q m3/h

P HP

1.2

5
0

Q m3/h

0.5

1.5

72.077

2.5

NPSH ft

10

H ft

Hm

100

30

H ft

Hm

40

20

CA

Self-Priming Liquid Ring Pumps

Features

Fast self priming


The hydraulic design ensures fast self priming once the pump body is filled
with water.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows CA series pumps to be selected
for use with different types of liquids.

Easy maintenance
The construction features an anti-wear ring screwed to the pump body,
allowing for rapid replacement in case of wear.

196

09/2016

NGL

Self-Priming Pumps
Construction
Close-coupled self-priming shallow-well pump with built-in
ejector.

Applications
For drawing water out of a well.
For lifting water containing air or other gases.
For increasing water pressure from flooded suction applications.
As pressure boosting pump for central water systems with low
pressure (follow local specifications if increasing network pressure).
For garden use.
For washing with a jet of water.

Operating conditions
Liquid temperature: 0 C to +35 C.
Ambient temperature up to +40 C.
Suction lift up to 9 m.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
NGL: three-phase 230/400 V 10%.
NGLM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component
Pump casing
Casing cover
Impeller
Wear ring impeller-diffuser
Diffuser
Ejector
Shaft
Mechanical seal

Material
Cast iron GJL 200 EN 1561
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Brass P-Cu Zn 40 Pb 2 UNI 5705
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
PPO-GF20 (Noryl)
PPO-GF20 (Noryl)
Chrome steel 1.4104 EN 10088 (AISI 430)
Carbon - Ceramic - NBR

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).

Characteristic curves n 2800 rpm


0
0

Imp. g.p.m.

U.S. g.p.m.

10

15

10

15

20

60

50

150

m
40
ft
NGL 3/13
100

30
NGL 3

NGL 4

20
NGL 2
10

0
0

m 3/h

Q l/min

1
10

50
3
50

2
20

30

40

4
60

5
70

80
72.1072.1

197

21

NGL

Self-Priming Pumps

Performance n 2800 rpm


230V

3~

400V

230V

1~

P2

P1

Q
A

NGL 2

2,8

1,6

NGL 3/A

2,8

1,6

m3/h

0,3

l/min

2,8

2,3

3,5

kW

kW

NGLM 2

3,3

0,7

0,45

0,6

45

40

30

20,5

19

NGLM 3/A

4,2

0,9

0,55

0,75

53

48

39

30

28

51

48

41,5

33

30,8

28

24,5

42

40

36

31

29

27

22,5

HP

NGL 3/13

3,7

2,2

NGLM 3/13

5,4

0,75

NGL 4/A

3,7

2,2

NGLM 4/A

5,4

0,75

P1 Max. power input. P2 Rated motor power output.

H
m

16,6 33,3 38,3 46,6 58,3 66,6

4,5

4,8

75

80

20,5

19

24
22

Tolerances according to UNI EN ISO 9906:2012

Characteristic Curves for different suction lifts Hs

60

0 U.S. g.p.m.

10

15

60

50

U.S. g.p.m.

10

15

20

25

50
HS = 9m

150

150

m
9

40

40

ft

30

100
5

7
6
20

0
0

m3/h

Q l/min

1
NGL 2

NGL 3

40

100
2

NGL 3/13

5
4

20

3
1

10

4
60

0 m3/h 1
0 Q l/min 20

2
40

10
9
Hs
8
m
7

72.1072.3

Check valve.
Valvola
di
non ritorno

4 3 3/13

30
ft
25

20

Hs
G1
DN 25
(i 28 mm)

NGL

5
15
4
10

3
2

5
1

t min

5
80

6
100
72.1072.1

Self-priming capability

0,5 m

50

4
60

72.1072.1

0,5 m

NGL 4

50

2
20

8
7

HS = 9m

30

6
8

10

ft

Suction lift.
Hs (m) Altezza
di aspirazione
Self-priming
time.
t (min) Tempo
di autoadescamento

198

NGL

Self-Priming Pumps

Dimensions and weights

fM
115
161

116

ISO 228

4.93.367

33
95
210

30

10

G1

51

G1 ISO 228

112

w1

146

Net weight
Peso
netto
kg

Dimensions
Dimensioni
TYPE
TIPO

mm
fM

w1

NGL

NGLM

NGL 2

362

176

102

10,3

10,3

NGL 3/A

391

192

112

11,4

12,3

NGL 3/13

391

192

112

12,5

13,5

NGL 4/A

391

192

112

12,5

13,5

199

21

NGL

Self-Priming Pumps

Features

3.93.122

* Patented

A different pump with new features


An exclusive diffuser design with flow control device* provides for compact construction,
fast self-priming capability and low noise.

Reliable
With new design features the NGL is more robust and forgiving when temporary abnormal
operating conditions may exist.

Compact
The NGL is smaller than conventional pumps of a similar type, allowing for installation in
restricted spaces and providing for easier retrofit applications.

Safe
Fast air evacuation reduces the risk of air-pockets developing at the mechanical seal
preventing the danger of seal failure due to a lack of flushing and cooling.

Better self-priming
The NGL are capable of lifting water from depths of 9 m in less than 3 minutes, offers new
possibilities on suction lift applications and provides better trouble free service on normal
shallow-well suction lift duties, also with a long suction pipe above the water level.

Low noise
The new diffuser and flow control device* guide the fluid from the impeller into the central
part of the pump casing, reducing turbulence and velocity, with effective use of the
surrounding liquid in dampening the noise of flow.

200

09/2016

NGX

Self-Priming Pumps
Construction
Close-coupled self-priming shallow-well pump with built-in
ejector.
A high-quality pump for domestic water supply. Designed with
environmental considerations, featuring a stainless steel casing,
brass alloy impeller with minimal use of plastic materials.

Applications
For drawing water out of a well.
For lifting water containing air or other gases.
For increasing water pressure from flooded suction applications.
As pressure boosting pump for central water systems with low
pressure (follow local specifications if increasing network
pressure).
For garden use.
For washing with a jet of water.

Operating conditions
Liquid temperature: 0 C to +35 C.
Ambient temperature up to +40 C.
Suction lift up to 9 m.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
NGX: three-phase 230/400 V 10%.
NGXM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component
Pump casing
Casing cover
Impeller
Wear ring impeller-diffuser
Diffuser
Ejector
Shaft
Mechanical seal

Material
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Brass P-Cu Zn 40 Pb 2 UNI 5705
Cr-Ni steel 1.4301 EN 10088 (AISI 304)
PPO-GF20 (Noryl)
PPO-GF20 (Noryl)
Chrome steel 1.4104 EN 10088 (AISI 430)
Cr-Ni steel 1.4305 EN 10088 (AISI 303) for NGX 5,6
Carbon - Ceramic - NBR

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).

Characteristic curves n 2800 rpm


0

U.S. g.p.m.

10

15

20

25

30

35
200

60

NG
50

X4

/16

150

m
40

NGX

ft

4/18

NGX

5/16

100

30
NGX 6/18
NGX 5/18
NGX 6/22
NGX 3

20

NGX 5/22
NGX 4

NGX 2
10

m3/h
0
0 Q l/min 10

2
20

30

40

3
50

4
60

NGX 4/22

5
80

70

90

6
100

7
110

8
120

130

140

50

9
150
72.1072.1

201

22

NGX

Self-Priming Pumps

Performance n 2800 rpm


230V 400V

3~

1~

230V

P1

kW

m3/h
Q
HP
l/min

P2

0,3

0,45 0,6

45

40

0,9 0,55 0,75

53

48

39

27

22

42

40

36 30,5 28

25

kW

NGX 2

2,8

1,6

NGXM 2

3,3

0,7

NGX 3/A

2,8

1,6

NGXM 3/A

4,2

NGX 4/A

3,7

2,2

NGXM 4/A

5,4

0,75

NGX 4/16

4,5

2,6

NGXM 4/16

1,6

1,1

1,5

NGX 4/18

4,5

2,6

NGXM 4/18

1,6

1,1

1,5

NGX 4/22

4,5

2,6

NGXM 4/22

1,6

1,1

1,5

230V

P1

kW

kW

m3/h
Q
HP
l/min

1,1

1,5

230V 400V

3~

1~

NGX 5/16

4,7

2,7

NGXM 5/16

7,4

1,6

NGX 5/18

4,7

2,7

NGXM 5/18

7,4

1,6

NGX 5/22

4,7

2,7

NGXM 5/22

7,4

NGX 6/18

7,5

4,3

NGXM 6/18

NGX 6/22

7,5

4,3

NGXM 6/22

P2

1,1

H
m

1,1

1,5

9,2

1,5

9,2

1,5

2,4

4,5

5,5

6,5

8,4

50 66,6 75 83,3 91,6 100 108 116 133 140

30 20,5 18
30

21 19,5

57,5 54 47,3 40 37,5 34 28,5 26


48

35 32,5 28,5 27

25

35,5 34,8 33 30,5 29,5 28 25,3 24

46 42,5 37

23

22

5,5

2,4

0,5

8,3 16,6 33,3 40

4,5

6,5

8,4

43 40,5 36,8 31,7 28,5

61 55,5 51
H
m

21 20,3 19,5 18 17,5

50 66,6 75 83,3 91,6 100 108 116 133 140

50,5 47,5 45 39,5 37,7 35 30,8 29

1,5

1,6

16,6 33,3 40

31 29,5 27

37,5 36 34,7 32

27 25,5 24

26 24,8 23,7 22,8 22

21

19 18,3

44 41,3 37 34,7 32,5 30,5 28,5

58 54,7 51,5 46

46,5 45 43,5 40,5 39,3 37,5 35 33,5 32,5 31,2 30 28,5 27,5 25,5 24,5

P1 Max. power input. P2 Rated motor power output.

Tolerances according to UNI EN ISO 9906:2012

Curve caratteristiche
altezze
di aspirazione
Hs
Characteristic
curvescon
fordiverse
different
suction
lifts Hs
0 U.S. g.p.m. 5

10

15

0 U.S. g.p.m. 5

20
200

60

16

/18

20

25

30

35
200

60

X
NG

3
40

X2
NG

ft

4
5

7
6
20

m3 /h 1
0
0 Q l/min 20

100

/18

X4
/1
NG 8
X4 9

150
9

30

NG

100

5
4

150

/22

NG

HS = 9m

NG
X6

40
ft

5
4

20

H
m

3
2

X5

50

NG

H N
G

150

30 HS = 9m

10

15

X6

50

16

40

0 U.S. g.p.m. 10

25

NG

4/

20

60

5/

X
NG

15

200

X
NG

50

10

30

X5

/22

ft
8

X4

/22

20

2
40

4
60

10
0 m3/h 1
0 Q l/min 20

5
80

2
40

50

5
80

60

6
100

10

0 m3 /h
0 Q l/min

3
50

72.1072.1

Self-priming
capability
Capacit di autoadescamento
50 Hz (n 2800 1/min), H2O, T = 20C, Pa = 1000 hPa (mbar)

10
4

9
Hs
8
m
7

0,5 m

72.1072.3

Check valve.
Valvola
di
non ritorno

G 1 DN 25
(i 28 mm)
NGX 2,
NGX 3,
NGX 4.
G 11/4 DN 32
(i 36 mm)
NGX 4/16,
NGX 4/18,
NGX 4/22,
NGX 5,
NGX 6.

50

18
6/ 2
2
6/

5/

18 22
16 5/ 5/

4/

16

30
ft

/22

4/1

25

20

6
5

Hs

NGX 2
NGX 3
NGX 4
NGX 4/16
NGX 4/18
NGX 4/22
NGX 5/16
NGX 5/18
NGX 5/22
NGX 6/18
NGX 6/22

4
3
2
1

t min

202

2 1

72.1072.1

0,5 m

100

HS = 9m

15

10

Hs (m) Suction
Altezzalift.
di aspirazione
t (min) Self-priming
Tempo di autoadescamento
time.

3 2
1

6
100

50
8

9
150
72.1072.1

NGX

Self-Priming Pumps

Dimensions and weights

NGX 2, 3/A, 4/A, 4/16, 4/18, 4/22


fM
a
DN2

H
h1

ISO 228

DN1

h2

ISO 228

4.93.281

m3
m1
w1

g1

m2

b
n2
n1

Net weight
Peso
netto
kg

Dimensions
Dimensioni

mm

DN1 DN2
ISO 228

m3

n1

n2

g1

w1

NGX NGXM

33

25

146

112

30

10

102
112
112

7,5 7,5
8,7 9,6
9,6 10,6

28

9,5

185 155

33

9,5

11

147 14,8 14,8

h1

h2

G1

362
391
391

115

95

116

61

176
192 161
192

G 1 1/4 G 1

462

140

113

152

68

225 213,5 37,5

22
NGX 5, 6
488,5
140
G1

213,5

240

68

ISO 228

152

G1 1/4

NGX 4/16
NGX 4/18
NGX 4/22

m2

G1

m1

fM

ISO 228

NGX 2
NGX 3/A
NGX 4/A

28

9,5

11

TYPE
TIPO

37,5
113

9,5
155
185

157,5

Net weight
Peso
netto
kg

TYPE
TIPO

NGX

NGXM

NGX 5

15,2

16,7

NGX 6

17,8

18,2

203

33

NGX

Self-Priming Pumps

Features

3.93.122

* Patented

A different pump with new features


An exclusive diffuser design with flow control device* provides for compact construction,
fast self-priming capability and low noise.

Reliable
With new design features the NGX is more robust and forgiving when temporary abnormal
operating conditions may exist.

Compact
The NGX is smaller than conventional pumps of a similar type, allowing for installation in
restricted spaces and providing for easier retrofit applications.

Safe
Fast air evacuation reduces the risk of air-pockets developing at the mechanical seal
preventing the danger of seal failure due to a lack of flushing and cooling.

Better self-priming
The NGX are capable of lifting water from depths of 9 m in less than 4 minutes, offers new
possibilities on suction lift applications and provides better trouble free service on normal
shallow-well suction lift duties, also with a long suction pipe above the water level.

Low noise
The new diffuser and flow control device* guide the fluid from the impeller into the central
part of the pump casing, reducing turbulence and velocity, with effective use of the
surrounding liquid in dampening the noise of flow.

204

09/2016

NG

Self-Priming Pumps
Construction
Close-coupled self-priming shallow well jet pumps with
built-in ejector.
NG: version with pump casing and lanter bracket in cast iron.
B-NG: version with pump casing and lanter bracket in bronze
(the pumps are supplied fully painted).

Applications
For drawing water out of a well.
As pressure boosting pump for central water systems with
low pressure (follow local specifications if increasing network
pressure).
For clean liquids or slightly dirty surface water.
For garden use.
For washing with a jet of water.

Operating conditions
Liquid temperature up to 40 C.
Ambient temperature up to 40 C.
Maximum permissible working pressure up to 10 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
NG: three-phase 230/400 V 10%.
NGM:single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components
NG
B-NG
Pump casing
Cast iron
Bronze
Cover with lantern bracket
GJL 200 EN 1561
G-Cu Sn 10 EN 1982
Diffuser plate
Impeller
Brass P- Cu Zn 40 Pb 2 UNI 5705
Shaft
Cr steel 1.4104 EN 10088
Cr-Ni-Mo steel
(AISI 430) for NG 3-4
1.4401 EN 10088
Cr-Ni steel 1.4305 EN 10088
AISI 316
(AISI 303) for NG 5-6-7-32
Ejector casing NG 32 Cast iron GJL 200 EN 1561
Diffuser
PPO-GF20 (Noryl)
Nozzle
PPO-GF20 (Noryl) (Brass P- Cu Zn 40 Pb 2 UNI 5705 for NG 32)
Mechanical seal
Carbon - Ceramic - NBR

Characteristic curves for suction lift Hs = 1 m


0

Imp. g.p.m.

10

0 U.S. g.p.m.

15

10

15

- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).


- Protection IP55.
- Special mechanical seal

2900 rpm

Imp. g.p.m. 10

20

0 U.S. g.p.m.10
80

20

100

Special features on request

20

0 Imp. g.p.m.

20

0 U.S. g.p.m.
70

30

20

30
30

40

250
300

90

200

60

70
80

m
60
50

200

60

H
ft

200

m
50

NG 7/16

H
ft

NG 7/18

NG 32

NG 6/18

40

30

NG 6/22 100

30

3
40

20

NG 5/18
NG 5/22

NG 4

NG 3
2

NGM 6/22

100

100

30

NG 7/22

NGM 6/18

NG 5/16

m3 /h
l/min

150
ft

m
40

150
40

20
0
0

50

4
60

5
80

20
0
0

m3 /h 2
l/min

3
50

6
100

10
0
0

m3 /h

Q l/min 50

6
100

10
150
72 861

205

50

23

NG

Self-Priming Pumps

Performance for suction lift Hs = 1 m

2900 rpm
Q

3~

230V 400V

1~

230V

P1

kW

P2

B- NG 3/A

1,7

B- NGM 3/A

4,5

B- NG 4/A

3,7

2,2

B- NGM 4/A

5,7

NG 32E

4,7

2,7

NGM 32E

7,4 1,47 1,1

B- NG 5/16E

4,7

2,7

B- NGM 5/16E

B- NG 5/18E

4,7

2,7

B- NG 5/22E

4,7

2,7

B- NG 6/18E

7,5

4,3

kW

m3/h 0,25 0,5

1,5

2,5

3,5

36

32

28

24

39

36

33

31

29

26

24

21

1,5

49

46 43,5 41

39

38

36

34

7,4 1,64 1,1

1,5

59

54

46

43

40

37 34,5 32

B- NGM 5/18E

7,4 1,68 1,1

1,5

48,5 46 43,5 41,5 39,5 38 35,5 34

B- NGM 5/22E

7,4 1,55 1,1

1,5

35,5 34,5 33 31,5 30,5 29,5 28

9,2

0,9 0,55 0,75


1

0,75

1,5

1,5

1,5

41

H
m

50

27

32 30,5 29
26

9,5

28

25 23,5 23 21,5 20,5 18,5 16,5 15,5

56

54

51 48,5 46 43,5 41,5 39 36,5

51

48

45

43

40 37,5 35

1,5

47

45 43,5 42

41

40

38

37

2,2

89

83

72

67

62

58

54

B- NG 7/18/A

9,15 5,3

2,2

B- NG 7/22/A

9,15 5,3

2,2

P2 Rated motor power output.

6,5

31

54

9,15 5,3

33

59

B- NG 7/16/A

9,2

57

59

7,5

B- NGM 6/22E

5,5

64,5 62

B- NG 6/22E

4,3

HP l/min 4,1 8,3 16,6 25 33,3 41,6 50 58,3 66,6 75 83,3 91,6 100 108 116 133 150 158
49 45,5 40

B- NGM 6/18E

P1 Max. power input.

4,5

51,5 50 48,5 47
77

46 44,5 43 41,5 40

74,5 71,5 68,5 65,5 63


59 57,5 56,5 55

B-NG, B-NGM = Bronze construction.

206

30

36

35

33

32

31

53

51

49

47

45

27

24

23

50 48,5 47 45,5 44 42,5 41,5 38

35

34

60 57,5 55

54 52,5 51

33

39 37,5 36,5 35 33,5 31 28,5 27


30

Tolerances according to UNI EN ISO 9906:2012

NG

Self-Priming Pumps

Characteristic curves n 2900 rpm


0 U.S. g.p.m.

10

12

14

NG 3

45

0 U.S. g.p.m.

10

12

14

40

18
140
130

130

160

130

16

NG 4

180

50

120
35

40

110

Hm

140
H ft

Hm

120

100

30

90

100

30

H ft

60

25

80

80
70
0
0
0

3
Q m /h 0.5
l/min
10

l/s

1.5
20

0.2

0.3

2.5
40

30
0.4

0.5

0.6

20

3
50

0.7

0.8

3
0
Q m /h
0
l/min 10

0.7

l/s

2
20

0.2

30

40

0.4

0.6

3
50
0.8

4
60

70

0.7

0.7

0.5

0.9
0.6

0.8

0.6

25

20
15

10
2

50

NPSH m

Q m3/h 0.5

10

1.5

2.5

72.163

10

20

28
160
150

130

40

130

H ft

140

120
35
110
100
3
0
Q m /h 1
0
20
l/min

2
30

40

3
50

4
60

5
70

80

90

6
100

1,4

1,2

P kW

1,6
1,4

1,0

P HP

1,8

1,2
0.8
0 Q m3/h

0 Q m3/h

72.164

23

0 U.S. g.p.m.

45

Hm

20
5

NG 32

30

0.7

0.5

NPSH ft

NPSH m

0.4

P HP

0.8

P kW

0.6

P HP

P kW

0.9

NPSH ft

20

72.179

207

NG

Self-Priming Pumps

Characteristic curves n 2900 rpm


70

0 U.S. g.p.m.

10

15

20

60

0 U.S. g.p.m.

10

20

220

NG 5/16

NG 5/18

200

60

28

180

50

160
143

143

140
H ft

160

Hm

50

H ft

Hm

180
40
120
140
40

100

30
120

80
30

100
0 Q m3/h
l/min
0
0

l/s

2
20

0.2

30

3
50

40

0.4

0.6

20

4
60

0.8

70

1.2

0 Q m3/h 1
0 l/min
20
0

l/s 0.2

0.4

3
40

0.6

60
0.8

80

1.2

1.4

6
100
1.6

1.2

P kW

P HP

P kW

1.6

1.5

1.1

P HP

1.6

1.2

25
20
15
10
5
0

6
4
2
0

40

0 Q m3/h

0 U.S. g.p.m.

10

20

72.168

30

120

134

Hm

80

H ft

100

30

20
60

40
3

0
0

Q m /h

l/s

l/min

6
100

50
0.5

1.5

10
150

2.5

P kW

1.2

1.6
1.5

1.1

1.4

P HP

10

1.0
1.3

25

20
15

10
2
0

NPSH ft

NPSH m

0.9
8

5
0

Q m3/h

72.170

10

4
2

40

NG 5/22

208

Q m3/h 1

72.169

25
20
15
10
5
0

NPSH ft

1.0

NPSH m

1.5

NPSH ft

NPSH m

1.4
1.1

NG

Self-Priming Pumps

Characteristic curves n 2900 rpm


10

20

28
60

30

40

160

160

NG 6/22
157

180

NGM 6/18
149

180

50

Hm

Hm

20

NG 6/22

200

NG 6/18
157

50

10

220

NG 6/18
60

0 U.S. g.p.m.

140
40

H ft

0 U.S. g.p.m.

H ft

70

NGM 6/22
149

120

140
40

100

30
120

80

2
20

l/s

0.4

30

40
0.6

3
50
0.8

4
60

5
70

1.2

80
1.4

1.6
NG 6/18

2.2

1.5

NGM 6/18

P kW

0.4

60

80

0.8

1.2

6
100
1.6

8
120

10
160

140

2.4

NG 6/22

2.6
2.4
2.2

1.6

NGM 6/22

2.0

2.0

1.4
1.8

6
4
2
0 Q m3/h

25
20
15
10
5
0
72.171

NPSH ft

NPSH m

1.8

1.3

1.2

1.6

25

20
15

10
2
0

NPSH ft

P kW

4
40

1.8

1.4

NPSH m

l/s

2.0

2.4

1.6

0 Q m3/h
0 l/min
0

1.8
1.7

20

6
100

90

P HP

0 m3/h
Q
0 l/min

P HP

30

100

5
0 Q m /h
3

72.172

10

23

209

NG

Self-Priming Pumps

Characteristic curves n 2900 rpm


0
100

U.S. g.p.m. 5

10

15

0 U.S. g.p.m.
80

20

10

20

260

NG 7/18

310

NG 7/16

90
164

30

290

240

164

70

220

270

230

70

180

210
60

160
140

170
3

Q m /h

l/min

l/s

2
20

0.2

30

40

0.4

0.6

3
50

4
60

0.8

5
70

40
3
0
Q m /h 1
0
l/min 20

80

0
2.2

1.2

l/s

0.4

3
40

0.6

60
0.8

80

1.2

1.4

6
100
1.6

7
1.8
2.9

2.8

P kW

2.1
P HP

P kW

3.0
2.1

2.8
2.0

2.7

1.9

2.6

2.6

1.9

2.4

2.5

1.7

1.8
10

NPSH m

30

8
20

6
4

10

2
0

Q m3/h

0 U.S. g.p.m.
70

10

20

72.178

30

NPSH ft

NPSH m

10

200
164

160

H ft

Hm

180
50

140
40
120

l/min

l/s

4
40

0.4

60

80

0.8

1.2

6
100
1.6

8
120

140

100
10
160

2.4

P kW

2.1

2.8

2.0
2.6

1.9
1.8

P HP

0
2.2

Q m /h

2.4
2.2

25

20
15

10
2
0

NPSH ft

NPSH m

1.7
1.6

5
0

Q m3/h

72.174

10

20

6
4
0

220

60

30

10

40

NG 7/22

30
0
0

P HP

0
2.3

50

190

210

0 Q m3/h 1

72.173

NPSH ft

50
0
0

200

60

H ft

Hm

250

H ft

Hm

80

NG

Self-Priming Pumps

Dimensions and weights


NG 3/A,4/A,5E,6E,7/A

NG 32E

fM

fM

a1
DN2

DN1

h2

a2

a2

a1
DN2

h2
H

h1

DN1

g h1

4.93.104

m2
m1
w

TYPE
TIPO

m3

m2

b
n2
n1

DN1

m3

s
n2
n1

m1
w

mm

DN2

ISO 228

kg

a1

a2

fM

h1

h2

m1

m2

m3

n1

n2

NG

B-NG

NG 3/A
NG 4/A

B-NG 3/A
B-NG 4/A

G1

G1

127

430

150

43

207

60

52

185

155

35

9,5

100

11

18,4
19,2

20,8
21,5

NG 5E
NG 6E
NG 7/A

B-NG 5E
B-NG 6E
B-NG 7/A

G 11/2

G1

160

10

560
560
600

165

57

240

60

50

10

215

175

40

11,5

115

11

29,2
30,8
31,3

31,6
32,9
33,4

G 11/2

G1

75

175

557

112

108

222

60

34

26

215

175

40

11

106

10

38

NG 32E

23
Installation examples

Positive suction head operation

Suction lift operation

1m

Check valve.

3.93.100.1

4.93.100

Check valve.

211

NG

Self-Priming Pumps

Features

3.94.116

Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid
are dimensioned to guarantee the maximum resistence to mechanical stress.

Self priming
The hydraulic design allows the pump to self prime even with the high suction
lifts or with long suction pipe runs above the water level.

Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NG series pumps to be selected
for use with different types of liquids.

212

09/2016

MXA

Multi-Stage Self-Priming Pumps

Construction
Horizontal multi-stage, self-priming, close coupled
pump.
Single-piece barrel casing in chrome-nickel stainless
steel, with front suction port above pumps axis and
radial delivery at top.
Stages in Noryl.

Applications
For water supply.
For domestic use, for garden use and irrigation.

Operating conditions
Liquid temperature: 0 C to +35 C.
Ambient temperature up to +40 C.
Suction lift up to 8 m.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2800 rpm).
MXA:
three-phase 230/400 V 10%.
MXAM: single-phase 230 V 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Component

Material

Pump casing
Casing cover

Cr-Ni steel 1.4301 EN 10088 (AISI 304)


Cr-Ni steel 1.4301 EN 10088 (AISI 304)

Pump Shaft

Chrome steel 1.4104 EN 10088 (AISI 430)

Plug

Cr-Ni steel 1.4305 EN 10088 (AISI 303)

Suction casing
Stage casing
Impeller

PPO-GF20 (Noryl)
PPO-GF20 (Noryl)
PPO-GF20 (Noryl)

Mechanical seal

Carbon - Ceramic - NBR

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).

24

Characteristic curves n 2800 rpm

50

205

H2O, T = 20C,
Pa = 1000 hPa (mbar)
50 Hz (n 2800 1/min)

405

150

Hs

40

204

8
m

ft

404

204
100
200
450
600

MXA 205

205
500
500
500
600

403
100
450
600
600

404
100
450
600
600
3

405
500
500
600
600
404 25

20

7
403

40

0,5 m

100

30

h (mm)
203
100
200
450
600

MXA

Hs
(m)

2
4
6
8

20

Self-priming
capability

60

203

ft
20

6
403

m3/h

Q l/min

4
50

NPSH
50

8
NPSH
6
m
4

G 1 1/4 DN 32
(i 36 mm)
MXA 205,405

Hs
3

10

2
5

30
20
0

G 1 DN 25
(i 28 mm)

6
100

15

Check valve

50
10
0
0
60

72.1141

20

m3/h

72.1140

0
8

Hs (m) Suction lift

213

t min 1

t (min) Self-priming time

MXA

Multi-Stage Self-Priming Pumps

Performance n 2800 rpm


230 V 400 V

3~

MXA 203
MXA 204/A
MXA 205/A

A
2,4
2,8
3,5

A
1,4
1,6
2

1~

MXA 403/A
MXA 404/A
MXA 405/A

A
2,8
3,5
4,5

A
1,6
2
2,6

P1

A
3
4,2
5,4

kW
0,63
0,8
1

230 V

P1

A
4,2
5,4
7

kW
0,9
1,2
1,5

MXAM 203
MXAM 204/A
MXAM 205/A

230 V 400 V

3~

230 V

1~
MXAM 403/A
MXAM 404/A
MXAM 405/A

P1 Max. power input.


P2 Rated motor power output.

P2

kW
0,45
0,55
0,75

HP
0,6
0,75
1
P2

kW
0,55
0,75
1,1

m3/h

4,5

l/min

16,6

33,3

50

66,6

75

83,3

32
45
55,5

28
40
50

24
34
43

19
27
35,5

14
20
26,5

15
21,5

15,5

6,5

33,3

50

66,6

83,3

100

108,3

116,6

133,3

34
45
56

30
40
51

28
37
47,5

25
33
42,5

22
28
36,5

17
22
30

15
19
26,5

15
23

14

HP
0,75
1
1,5

m 3/h
l/min

Test results with clean cold water, without gas content.


+ 0,5 m security margin on NPSH-value is necessary.

Tolerances according to UNI EN ISO 9906:2012


For capacities over 4 m3/h use a suction pipe G 1 1/4 (DN 32).

Dimensions and weights


fM
a
DN2

H
h1

ISO 228

DN1

h2

ISO 228

4.93.281

m3
m1
w1

TYPE
TIPO

DN1

MXA 203 - MXAM 203


MXA 204/A - MXAM 204/A
MXA 205/A - MXAM 205/A
MXA 403/A - MXAM 403/A
MXA 404/A - MXAM 404/A
MXA 405/A - MXAM 405/A

G1
G1
G 1 1/4
G1
G1
G 1 1/4

G1
G1
G1
G1
G1
G1

b
n2
n1

Net
weight
Peso
netto

Dimensions
Dimensioni
mm

DN2

ISO 228

g1

m2

fM
362
391
462
391
391
462

h1

115 95 116
115 95 116
140 113 152
115 95 116
115 95 116
140 113 152

kg

h2

m1

m2

m3

n1

n2

g1

w1

61
61
68
61
61
68

176
192
225
192
192
225

161
161
213,5
161
161
213,5

33
33
37,5
33
33
37,5

25
25
28
25
25
28

8
8
9,5
8
8
9,5

146
146
185
146
146
185

112
112
155
112
112
155

30
30
33
30
30
33

9
9
9,5
9
9
9,5

10
10
11
10
10
11

102 6,6
112 8,7
147 12,5
112 8,6
112 9,5
147 14,5

MXA MXAM
6,7
9,6
13,8
9,5
10,5
14,5

Features
Extra safety
against running dry, with the suction port above
pump axis and with the self-priming construction.

Robust
Single-piece barrel casing.

Compact
Single-piece lantern bracket and base.

Low noise
with the water-filled shroud around the stages.
3.93.124

214

09/2016

I, IR

Gear Pumps
Construction
Close-coupled gear pumps (rotary pumps).
Pump casing with suction and delivery connections with the
same diameter and on the same axis (in-line execution).

Applications
For fuel oil and liquids with lubricating properties.

Operating conditions
Kinematic viscosity from 30 mm2/s (4E) to 120 mm2/s (15E).
Liquid temperature up to 90 C.
Ambient temperature up to 40 C.
Total suction lift up to 4 m.
Continuous duty.

Motor
4-pole induction motor, 50 Hz (n 1450 rpm).
I, IR, IRR: three-phase 230/400 V 10%.
IM: single-phase 230 V 10%.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components

Materials

Pump casing

Cast iron GJL 200 EN 1561

Gears

Steel 18 Ni Cr Mo 5 UNI 8550

Special features on request

Shafts

Steel 18 Ni Cr Mo 5 UNI 8550

Radial shaft seal ring

FPM

Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP55.
Higher ambient temperatures.

25
Performance
3~

1450 rpm

230 V 400 V

1~

230 V

P1

P2

m3/h

0,6

l/min

10

Q
I
25/4/A
IR
25/4/A
IRR 25/4/A

1,4
2,1
3,3

0,8
1,2
1,9

P1 Max. power input.

IM25/4/A

kW

kW

HP

rpm

2,1

0,4

0,25
0,37
0,75

0,34
0,5
1

1450
1450
1450

P2 Rated motor power output.

p
bar

2
2,5
5

p Differential pressure.

215

I, IR

Gear Pumps

Dimensions and weights


319

140
120

G1

G1

35

ISO 228

10 kg
11,7 kg
11,6 kg

ISO 228

I 25/4 /A:
IM 25/4 /A:
IR 25/4 /A:

182
88
10
4.93.224

10

22

90

112

106

134

368

120

G1
10

G1

205

ISO 228

160

35
ISO 228

IRR 25/4/A: 17,6 kg

97

107.5

4.93.065

9.5
125

30

100

125

117

155

Features

Innovative structure
The flanged pump casing and two piece shaft allows the hydraulics to be
disassembled easier, facilitating quick maintenance operations.
216

09/2016

B-VT

Peripheral Immersion Pumps


Construction
Vertical close-coupled peripheral (regenerative) pumps with
submerged turbine impeller, seal-less, reversible.
Port dimension to EN12157.
Submerged deph 170 mm.

Applications
For clean liquids without abrasives, without suspended
solids, non-explosive, non-aggressive for the pump materials.
For the reduced dimensions, these pumps are very well
suited for use with temperature, controllers chillers, and airconditioning machines and systems.

Operating conditions
Liquid temperature:

- with water up to 90 C.
- oil up to 180 C.
Max. kinematic viscosity: 20 mm2/s at 50 C (2,9 E).
Ambient temperature: up to 40 C.
Max. depression 0,9 bar.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
B-VT: three-phase 230/400 V 10% (220-240 / 380-415 V).
Insulation class F.
Protection IP 54.
Constructed in accordance with: EN 60034-1.

Materials
Components

Materials

Pump casing
Casing cover

Bronze G-Cu Sn 10 EN 1982


Bronze G-Cu Sn 10 EN 1982

Impeller
Shaft
Bearing sleeve
Bearing in the casing
Screws

Brass P- Cu Zn Pb 2 UNI 5705


Chrome steel 1.4104 EN 10088 (AISI 430)
Corrosion-resistant Cr-Mo steel
Polymer
Cr-Ni steel 1.4301 EN 10088 (AISI304)

Special features on request


- Terminal box arrangement 2-3-4 in accordance with EN 12157.
- Other voltages.
- Frequency 60 Hz.
- Protection IP55.

Characteristic curves with water at 20 C ( = 1 mm2/s)


0 U.S. g.p.m. 2
0 Imp. g.p.m.

10

12

2900 rpm

14

10

50

160

B-VT

140

40
120

B-VT 65/170
30

100

H
ft

B-VT 60/170

20

60
40

10
20
0

0
0

m 3/h
Q l/min

1
10

2
20

30

3
50

40

72.1159

217

26

B-VT

Peripheral Immersion Pumps

Performance n 2900 rpm


3~

B-VT 60/170
B-VT 65/170

230V

400V

kW

HP

m3/h
Q
l/min

1,9
2,8

1,1
1,6

0,33
0,45

0,45
0,6

H
m

P2

P2 Rated motor power output.

0,3

0,48

0,6

0,75 0,96

1,2

1,5

1,89

2,4

10

12,5

20

25

31,5

40

50

15
23

8,5
17,5

2
10

43
37
48,5 42,5

33
39

16

30,5 27,5 23,5 19,5


37 34,5 31
27

H Pump outlet head

Dimensions and weights


1

15

Terminal box arrangement (view from motor side)


EN 12157

B-VT 60/170: kg 8,2


B-VT 65/170: kg 8,4

1
Standard

7
95

70

On request

25

20

218

G 3/4 ISO 228

2, 3, 4

MAX.
99.8
170

130

MIN.
40

Features

Range
The high number of pumps in the range can meet the
widest range of services required by the user.

Construction with no mechanical seal


The absence of a mechanical seal minimizes the need
for maintenance of the pumps.

Float switch
The pumps can be fitted with a float switch, eliminating
the need for level control systems.

218

09/2016

VAL,SC

Vertical Submerged Pumps


Construction
Vertical column sump pumps, with motor in dry installation and
with pump body submerged in the liquid handled (without suction line or foot valve).
Impeller - VAL:free-flow impeller (vortex or recessed impeller).
- SC: open impeller.
Connection - VAL 30, SC 30, SC50: threaded port ISO 228 (BS 2779).
- VAL65: flange with plain face oval threaded
counter-flange UNI 2245, PN 2,5.

Applications
For draining a basin or a sump with domestic or industrial sewage.
For slightly dirty waste water, for liquids which are non-aggessive
for the pump materials.

Operating conditions
Liquid temperature up to 40 C.
Ambient temperature up to 40 C.
Continuous duty.
Maximum size of solids: VAL30 = 25 mm; VAL 65 = 50 mm;
SC30 = 3 mm; SC 50 = 6 mm.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
VAL -SC: three-phase 230/400 V 10%.
VALM-SCM: single-phase 230 V 10%, with thermal protector.
Insulation class F.
Protection IP 54.
Classification scheme IE2 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.

Materials
Components
Pump casing
Lower bearing housing*
Impeller

VAL

SC

Cast iron
GJL 200 EN 1561

Cast iron
GJL 200 EN 1561

Brass P-Cu Zn 40 Pb 2 UNI 5705


for VAL 30

Brass
P-Cu Zn 40 Pb 2 UNI 5705

Cast iron GJL 200 EN 1561


for VAL 65

Shaft
Bearing bush
Shaft sleeve

Special features on request


-

Steel C 40 UNI 7231


Tecnopolymer
Chromate bronze
for VAL 65

* Not existing for VAL30.

Characteristic curves
4 Imp. g.p.m. 10
5 U.S. g.p.m.

20
20

2900 rpm

30 40 50
30 40 50

Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP55.
Bronze bearing bush (for liquid up to 100 C).
Higher ambient temperatures.

100

27
4 Imp. g.p.m.

200

100

200

10

5 U.S. g.p.m.10

300

10

20
20

30
30

40 50

100

40 50

100

13

40

30

m
8

VAL

SC

10

ft

30
20

ft

20
4

65
65R

5
10

30
2
1

m /h

20

Q l/min

30
3

50

10
100

200

50
500

70

1000

m /h

20

Q l/min

50
10

50

10
100

20
200

30
500
72.869.C

219

VAL,SC

Vertical Submerged Pumps

Performance n 2900 rpm


3~

1~

230V 400V
A

230V P1

VAL30/A

2,3

1,3 VALM30/A

VAL65E

7,5

4,3

VAL65-R/A

9,15 5,3

SC 30/A

2,3

1,3 SCM 30/A

SC 50/A

2,3

1,3 SCM 50/A

P1 Max. power input.

P2

m3/h

3,5

4,5

5,5

6,5

7,5

10

12

14

16

18

20

25

3,6 0,63 0,45 0,6


1,5

2,2

6,7 6,5 6,2 5,9 5,6 5,3

4,7 4,3

H
m

2,8 0,47 0,37 0,5

11 10,6 10,2 9,6

3,6 0,69 0,45 0,6

8,3 7,4 6,5 5,4

10,3 10,2 10,1 10

P2 Rated motor power output.

7,1 6,9 6,6 6,3

5,6 5,3 4,5 3,7

7,1 6,9 6,6 6,3

5,6 5,3 4,5 3,7

9,9 9,8 9,7 9,4

H Total head in m.

6,7

Tolerances according to UNI EN ISO 9906:2012

Dimensions and weights

M
CALPEDA

fM
fM
L max
1)

L max
1)

DN
DN

VAL 30
SC 30
SC 50

L min

L min

VAL 65
VAL 65-R

h2
l1

h2

l2

l1

l2

l
AD

AD
4.93.058

4.93.173

1) Float switch (on demand)

TYPE
VAL 30/750/A
VAL 30/1000/A
VAL 65/1000E
VAL 65/1500E
VAL 65/2000E
VAL 65/2500E
VAL 65/1000-R/A
VAL 65/1500-R/A
VAL 65/2000-R/A
VAL 65/2500-R/A
SC 30/500/A
SC 30/750/A
SC 30/1000/A
SC 30/1250/A
SC 50/500/A
SC 50/750/A
SC 50/1000/A
SC 50/1250/A

G 1 1/4

G 2 1/2

G 2 1/2

G 1 1/4

G2

mm

DN
ISO 228

30

kW kW HP l/min 50 58,3 66,6 75 83,3 91,6 100 108 116 125 133 150 166 200 233 266 300 333 416 500

fM
1025
1275
1245
1745
2245
2745
1285
1785
2285
2785
765
1015
1265
1515
780
1030
1280
1530

h2

AD

L min

200

82

111

120

150

235

140

135

140

250

275

140

135

140

250

200

105

111

100

200

200

120

111

120

215

220

L max
750
1000
950
1450
1950
2450
950
1450
1950
2450
455
705
955
1205
470
720
970
1220

l1

l2

180

90

148

175

88

195

175

88

195

132

65

127

173

86

157

kg
17,8
19,5
40
48
56
64
43
51
59
67
17,4
19,6
21,8
24
18,5
20,7
22,9
25,1

VAL,SC

Vertical Submerged Pumps

Characteristic curves n 2900 rpm


0 U.S. g.p.m.10

15

20

25

30

35

40

45

0 U.S. g.p.m.

50

40

60

80

100

120

140

10
30

VAL 30
8

25

80

20

Hm

6
H ft

Hm

15

25

108

20

30

VAL 65

15

H ft

10

10

10
2

0
0
0

Q m /h

0
2

l/min

6
100

50

l/s 0.4

0.8

1.2

10

1.6

2.4

12
200

150
2.8

3.2

0.5

0
0

3
Q m /h 5

l/s 1

l/min

0
10
100

15
200

20

25
400

300
4

30
500
8

2.5

0.5

2.0

0.3

0.4

0.2

0.3

P kW

0.6
P HP

P kW

0.4

1.5

1.0

0.2
0.1

0.5

0.1

0
0

Q m3/h

0 U.S. g.p.m.

10

10

20

72.181

P HP

0
12

0
0

Q m3/h 5

10

0 U.S. g.p.m.

30

20

15

30

20

40

50

25

60

70

72.182

30

80

12

14
40

SC 30

95.5

27

35

95

10

SC 50
30

10

20

20
5

H ft

Hm

25
H ft

Hm

30

15

10

10

Q m /h

l/s

0
0

l/min 20
0.4

3
40

0.6

5
80

60
0.8

1.2

1.4

6
100
1.6

7
120

2.2

1.8

0.3

72.185

150

200

20
300
5
0.6
0.5

0.3

0.4

0.2

0.3

0.1

Q m3/h

100

15
250

0.2

0.1

l/s

l/min 50

10

P kW

P HP

P kW

0.1

0.4

0.3
0.2

Q m /h

0.5

0.4

0.2

0
0

0.1

221

Q m3/h

10

15

72.184

0
20

P HP

VAL,SC

Vertical Submerged Pumps

Features

Range
The high number of pumps in the range can meet the widest range of services
required by the user.

Construction with no mechanical seal


The absence of a mechanical seal minimizes the need for maintenance of the
pumps.

Float switch
The pumps can be fitted with a float switch, eliminating the need for level control
systems.

222

09/2016

GM 10

Submersible Drainage Pump


Construction
Submersible drainage pump constructed with composite polymers developed especially for this product.
These new rustproof materials are resistant to corrosion,
indeformable at maximum temperature differentials in the pump
and motor and resistant to internal and external strain.
Shaft of chrome steel AISI 430. Three lip seals in NBR.
With float switch for automatic start/stop.

Applications
For clean or slightly dirty water.
For draining flooded rooms or tanks.
Extraction of water from ponds, flowing water or pits for collection of rain water. For irrigation purposes.
For use outdoor, the power supply cable shall have a length not
less than 10 m.

Operating conditions
Maximum liquid temperature for prolonged use: 35 C (with
immersed motor).
Immersion depth: 5 m max (with suitable cable length).
Not suitable for continuous duty for prolonged time.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
Single-phase 230 V 10%, with thermal protector.
Capacitor inserted in the housing incorporated in the plug.
Cable: with plug, length 5 m, 245IEC57 4 G 0,75 mm2, according to EN 60335-2-41
for pumps up to 5 kg.
Insulation class B.
Protection IP 68.
Triple impregnation humidity-proof dry winding.

Special features on request


Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Cable H07RN8-F, 4 G 1 mm2, length 10 m, without plug.
Control box with capacitor, for pumps with cable without plug.
Without float switch.
With elbow on discharge port.
Motor suitable for operation with frequency converter.

Characteristic curve and performance n 2900 rpm


0 U.S. g.p.m. 10

30

20

40

28

50

ft

20

4
10
2

1~

230V Condensatore
Capacitor P1
A

0
0

m /h

12

l/min

50

100

150

200

kW

HP

GM 10 1,75 6,3 450 0,4

0,3

0,4

P1 Max. power input


P2 Rated motor power output
H Total head in m

m3/h

l/min

50

100 150 200

7,5

6,5

5,2

12

kW

223

P2

Hm

3,7

2,2

GM 10

Submersible Drainage Pump

Dimensions and weights


Weight kg 5

Control box (on request)


Type

Capacitor

QM 10
75

6,3 F

Weight

450 V

M20x1,5

0,4 kg
76

4.93.119

40

200

179

212

G 1 1/2

4.93.130

168

M20x1,5

Installation examples

Features
Maximum reliability
A metal support ensures correct alignment between the pump shaft
and the motor also in heavy duty conditions.
A threaded metallic insert in the delivery port allows for secure
connection of the delivery pipe or fitting without any risk of damaging
the pump.
A suction strainer prevents solids bigger than 8 mm grain size from
entering the pump.

Compact
Minimum dimension and high levels of performance, for use in many
different applications, for flow rates up to 200 liters/min.

Avviamento

300
Arresto
100

40

212

On

Off
3.93.004/2

G 1 1/2
ISO 228

179 max
min 350 x 350

Low cost installation


Immersed without suction pipe and valve. No filling operations at
start-up, no suction problems and greater safety against running dry.
3.93.003

224

09/2016

GXR, GXV

Submersible Pumps
in stainless steel
Construction
Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port.
GXR: with open impeller.
GXV: with free-flow (vortex) impeller.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.

Applications
GXR: - For clean water containing solids up to 10 mm grain size.
- For draining rooms or or emptying tanks.
- Extraction of water from ponds, streams or pits and
for rainwater collection.
- For irrigation purposes.
GXV: - For clean or slightly dirty water, containing solids up to
25 mm grain size.
- Particularly suitable for liquids with a high solid content.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60 335-2-41.

Operating conditions
Liquid temperature up to 50 C.
Maximum immersion depth: 5 m.
Minimum water level with float: GXR = 70 mm, GXV = 130 mm.
Minimum water level manual operation: GXR = 15 mm, GXV = 30 mm.
Continuous duty.

Materials
Component
Pump casing
Strainer
Impeller
Motor jacket
Pump jacket
Handle
Shaft
Mechanical seal
Seal lubrication oil

Material

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
GXR, GXV:
three-phase 230 V 10%;
three-phase 400 V 10%;
GXRM, GXVM: single-phase 230 V,
with float switch and thermal protector.
Incorporated capacitor.
Insulation class F.
Protection IP X8 (for continuous immersion)
Double impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Polypropylene
Chrome-nickel steel 1.4305 EN 10088 (AISI 303)
Ceramic alumina/Carbon/NBR
Oil for food/pharmaceutical machinery

Other features on request


- Other voltages. - Frequency 60 Hz. - Other mechanical seal. - Cable length 10 m.
- Vertical magnetic float switch. - Motor suitable for operation with frequency converter.

Characteristic curves n 2900 rpm


0

U.S. g.p.m.

20

30

40

50

60

14

U.S. g.p.m.

20

30

40

50

29

60

14

GXR

GXV
40

12
GX

10
GX

40

12

ft

ft

13

10
30

11

GX

H
GX

GX

20

5-8

20

6
GX

5-1

V2

30

V2

V2

5-6

4
10

10
2

0
0

m3/h
l/min 50

10
100

150

15
200

250

0
0

225

m3/h
l/min 50

10
100

150

15
200

250

GXR, GXV

Submersible Pumps
in stainless steel

Performance n 2900 rpm


230V 400V

3~

230V Capacitor

1~

GXR 9

1,6

0,9

GXRM 9

2,5

GXR 11

2,3

1,3

GXRM 11

3,5

GXR 13

2,8

1,6

GXRM 13

4,5

GXV 25-6

1,6

0,9

GXVM 25-6

2,5

GXV 25-8

2,3

1,3

GXVM 25-8

3,5

GXV 25-10

2,8

1,6

GXVM 25-10

4,5

kW

kW

450

0,5

0,25 0,33

12,5 450

0,7

0,37

0,5

450 0,95 0,45

0,6

16

230V Capacitor

1~

P2

Vc

230V 400V

3~

P1

HP

Vc

kW

kW

450

0,5

0,25 0,33

12,5 450

0,7

0,37

0,5

450 0,95 0,45

0,6

16

HP

1,2

4,5

7,5

10,2

12

13,2

l/min

20

50

75

100

125

150

170

200

220

8,3

4,8

3,6

2,5

1,7

11

10,4

9,5

8,5

7,5

6,5

5,3

4,2

2,2

12,7 11,7 10,7

9,7

8,5

7,3

6,3

5,2

3,2

m3/h

1,2

4,5

7,5

10,2

12

13,2

l/min

20

50

75

100

125

150

170

200

220

5,7

5,2

4,5

3,8

2,2

1,5

8,2

7,8

7,2

6,7

6,1

5,4

4,5

3,6

2,2

10

9,5

8,7

7,3

6,5

5,7

4,9

3,7

Hm

Density = 1000 kg/m .

P2 Rated motor power output.

P1 Max. power input.

Hm

P2

P1

m3/h

2,6

Kinematic viscosity = max 20 mm /sec.


2

Tolerances according to UNI EN ISO 9906:2012

Power supply cable

Pump
type

Cable material

Section

Float switch

Length

Plug

Cable material

Section

CEE 7(VII)

GXRM 9
GXVM 25-6

H05RN-F

3G0,75 mm2

5m

YES

H07RN-F

3G1 mm2

GXRM 11, 13
GXVM 25-8, 25-10

H07RN-F

3G1 mm2

5m

YES

H07RN-F

3G1 mm2

GXR 9
GXV 25-6

H05RN-F

4G0,75 mm2

5m

NO

NO

GXR 11, 13
GXV 25-8, 25-10

H07RN-F

4G1 mm2

5m

NO

NO

Dimensions and weights

fM

fM

10

25

56

56

Dimensions
mm

TYPE

ISO 228

G 1 1/4

ISO 228

G 1 1/4

176

4.93.411

176

4.93.388

fM

(1)
kg

TYPE

GXR GXRM

Dimensions
mm
fM

(1)
kg
GXV GXVM

265 230

5,2

GXV 25-6 - GXVM 25-6

302 267

5,1

5,3

GXR 11 - GXRM 11

300 265

6,2

6,5

GXV 25-8 - GXVM 25-8

337 302

6,3

6,6

GXR 13 - GXRM 13

300 265

6,7

7,2

GXV 25-10 - GXVM 25-10 337 302

6,8

7,3

GXR 9

- GXRM 9

(1) With cable length: 5 m

(1) With cable length: 5 m

226

GXR, GXV

Submersible Pumps
in stainless steel

Installation examples

G 1 1/4

G 1 1/4

ISO 228

ISO 228

On
On

375
340

Off

fM

Off

fM

130

70
3.93.037/3

3.93.037/3

176

176

min 350 x 350

min 350 x 350

29

Installation examples with vertical magnetic float switch

h
min

h
max

h fM
max

fM

h
min

3.93.037/3

3.93.037/3

176

176

min 250 x 250

min 250 x 250

mm

TYPE
fM

h
min

h
max

GXRM 9 GF

265

100

190

GXRM 11 GF

300

135

225

GXRM 13 GF

300

135

225

mm

TYPE

227

fM

h
min

h
max

GXVM 25-6 GFA

302

70

150

GXVM 25-8 GFA

337

70

185

GXVM 25-10 GFA

337

70

185

GXR, GXV

Submersible Pumps
in stainless steel

Features
PATENTED

G 1 1/4 vertical, upward delivery port for installation in


small pits, without the need for an elbow on the pump.

Handle in polypropylene.

Easy inspection of the


capacitor area.

Minimum dimension and high levels of


performance, for use in many different
applications, head up to 12,7 m and
flow rates up to 220 liters/min.

Shaft in chrome-nickel
stainless steel.
Easy adjustment of the
float switch: to allow the
adjustement of start/stop
pump levels.

Motor cooled by the pumped


water passing between the
motor jacket and the external
jacket.

Ceramic stainless steel shaft


sleeve.

Oil chamber.

GXR
GXV
Suction strainer with a double row of holes, for extra
safety against clogging.
GXV: it allows the passage of solids up to 25 mm.

Suction strainer with a double row of


holes, for extra safety against clogging.
GXR: it allows the passage of solids
up to 10 mm.
Impeller in chrome-nickel stainless steel.

The double shaft seal with oil chamber separates the


motor from the water and provides further protection
against accidental operation when dry.

228

GXR 12

Submersible Pumps
in stainless steel
Construction
Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port.
GXR: with open impeller.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.

Applications
- For clean water containing solids up to 12 mm grain size.
- For draining rooms or or emptying tanks.
- Extraction of water from ponds, streams or pits and for
rainwater collection.
- For irrigation purposes.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60 335-2-41.

Operating conditions
Liquid temperature up to 50 C.
Maximum immersion depth: 5 m.
Minimum water level with float: 70 mm,.
Minimum water level manual operation: 15 mm.
Continuous duty.

Motor

Component

Material

Pump casing
Strainer
Impeller
Motor jacket
Pump jacket

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Handle

Polypropylene

2-pole induction motor, 50 Hz (n 2900 rpm).


GXR: three-phase 230 V 10%;
three-phase 400 V 10%;
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GXRM: single-phase 230 V,
with float switch and thermal protector.
Incorporated capacitor.
Cable: H07RN-F, 3G1 mm2 (3G1,5 mm2 for 1,5 kW),
length 10 m, with plug CEI-UNEL 47166.
Insulation class F.
Protection IP X8 (for continuous immersion)
Double impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Shaft

Chrome-nickel steel 1.4305 EN 10088 (AISI 303)

Other features on request

Mechanical seal

Ceramic alumina/Carbon/NBR

Seal lubrication oil

Oil for food/pharmaceutical machinery

- Other voltages. - Frequency 60 Hz.


- Other mechanical seal. - Cable length 20 m.
- Vertical magnetic float switch.
- Motor suitable for operation with frequency converter.
- Three-phase pumps with incorporated float switch.

Materials

Characteristic curves n 2900 rpm


0

U.S. g.p.m.

20

40

60

80

100

120

29.1

140

22
70
20
GXR 12-20
60

18
GXR 12-18

l
a
n
o
i
s
i
v
e
r
P

GXR 12-16

m
14

50
ft

GXR 12-14
12

40

GXR 12-12
10

30

GXR 12-10
8
6
4
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

229

20

10

30
400

500

GXR 12

Submersible Pumps
in stainless steel

Performance n 2900 rpm


3~

230V 400V

230V Capacitor

1~

Vc

P1

P2

24

27

30

11,6

11

10,2

14

13,5 12,8

1,2

16

15,5

15

1,5

18

17,5

17

20

19,5 18,8

1,4

GXRM 12-12

3,6

16

450

0,55 0,75

2,8

1,6

GXRM 12-14

4,6

16

450

0,75

GXR 12-16

2,3

GXRM 12-16

25

450

1,3

0,9

GXR 12-18

4,8

2,8

GXRM 12-18

30

450

1,7

1,1

GXR 12-20

6,6

3,8

GXRM 12-20

12

35

450

2,2

1,5

l/min

Hm

Density = 1000 kg/m .

P2 Rated motor power output.

Tolerances according to UNI EN ISO 9906:2012

fM

Dimensions and weights

12

21

12

2,4

GXR 12-14

ISO 228

228

4.93.601

G 1 1/2

18

GXR 12-12

80

mm
fM
360
375
375
400
420
450

15

8,8

HP

0,7 0,45 0,6

TYPE

12

100 150 200 250 300 350 400 450 500

3,1 12,5 450

GXR 12-10 - GXRM 12-10


GXR 12-12 - GXRM 12-12
GXR 12-14 - GXRM 12-14
GXR 12-16 - GXRM 12-16
GXR 12-18 - GXRM 12-18
GXR 12-20 - GXRM 12-20

50

GXRM 12-10

P1 Max. power input.

9,5

1,2

kW

kW

10

A
GXR 12-10

m3/h

a
310
325
325
350
370
400

(1) With cable length: 10 m

230

kg (1)
GXR GXRM
11
12
11,5 12,5
11,5 12,5
13
15
14,5
16
16
17,5

3,2

5,5

14,2 13,2 11,8 10,2

5,5

2,3

16,2

4,3

1,5

12

18

6,7

7,5

5,5

10,8 9,3

7,5

15

13,7 11,8

16,8 15,2 13,2 10,8 8,4

5,7

Kinematic viscosity = max 20 mm /sec.


2

GXR 12

Submersible Pumps
in stainless steel

Installation examples

G 1 1/2
ISO 228

mm
TYPE

On

GXR 12-10 - GXRM 12-10


GXR 12-12 - GXRM 12-12
GXR 12-14 - GXRM 12-14
GXR 12-16 - GXRM 12-16
GXR 12-18 - GXRM 12-18
GXR 12-20 - GXRM 12-20

h
max
fM

Off
h
min

fM
360
375
375
400
420
450

h
min
255
270
270
295
315
345

h
max
380
395
395
420
440
470

3.93.037/3

228
min 350 x 350

Installation examples with vertical magnetic float switch

29.1

287.5
mm
TYPE
MAX

MIN

h
min

fM
h
max

GXRM 12-10 GF
GXRM 12-12 GF
GXRM 12-14 GF
GXRM 12-16 GF
GXRM 12-18 GF

4.93.602

3.93.037/3

228
min 300 x 300

231

fM
360
375
375
400
420

a
310
325
325
350
370

h
min
180
195
195
220
240

h
max
270
285
285
310
330

GXR 12

Submersible Pumps
in stainless steel

Features
PATENTED

Handle in polypropylene, with frame in


stainless steel.

G 1 1/2 vertical, upward delivery port for installation in


small pits, without the need for an elbow on the pump.

Easy inspection of the


capacitor area.

Shaft in chrome-nickel
stainless steel.
Easy adjustment of the float
switch: to allow the adjustement
of start/stop pump levels.
Motor cooled by the pumped
water passing between the
motor jacket and the external
jacket.

Chamber with food/pharmaceutical machinery oil

Impeller in chrome-nickel stainless


steel.

Suction strainer with a double row of holes, for extra


safety against clogging with the passage of solids up to
12 mm grain size.

The double shaft seal with oil chamber separates the motor
from the water and provides further protection against
accidental operation when dry.

232

09/2016

GQR

Submersible Drainage Pumps


Construction

PATENTED

Single-impeller submersible drainage pump, with open impeller.


GQR: with vertical threaded delivery port (G 1 1/2).
GQR 10 32: with horizontal flanged and threaded delivery
port (DN 32, PN 6 - G 1 1/2).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.

Applications
For clean water containing solids up to 10 mm grain size.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for rainwater
collection.
For irrigation purposes.

Operating conditions
Liquid temperature up to 35 C.
Maximum immersion depth: 5 m.
Minimum immersion depth: 205 mm.
Continuous duty (with submerged motor).

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
GQR: three-phase 230 V 10%;
three-phase 400 V 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GQRM: single-phase 230 V 10%,
with float switch and thermal protector.
Incorporated capacitor.
Cable: H07RN-F, 3G1 mm2, length 10 m, with plug
CEI-UNEL 47166.
Insulation class F.
Protection IP X8 (for continuous immersion)
Triple impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Component
Pump casing
Impeller
Strainer
Motor jacket
Jacket cover
Casing cover
Handle
Shaft
Mechanical seal: upper
lower
Seal lubrication oil

Material
Cast iron GJL 200 EN 1561

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Other features on request

Polypropylene (with frame in AISI 304)


Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).


- Other mechanical seal.
- Cable length 20 m.
- Vertical magnetic float switch.
- Motor suitable for operation with frequency converter.
- Three-phase pumps with incorporated float switch.

Ceramic alumina/Carbon/NBR
Oil for food/pharmaceutical machinery

Characteristic curves n 2900 rpm


0

U.S. g.p.m.

20

40

60

80

100

120

140

22
70
20

GQR 1
0 (32)20
GQR 1
0 (32)18
GQR 1
0 (32)16

18

H
m
14
12
10
8

60

50
ft

GQR 1
0 (32)14
GQR 1
0 (32)12

40

GQR 1
0 (32)10

30

20

6
4

10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

233

30
400

500

30

GQR

Submersible Drainage Pumps

Performance n 2900 rpm


230V 400V

3~

A
GQR 10-10
GQR 10 32-10

GQR 10-12
GQR 10 32-12

230V Capacitor

1~

Vc

P1
kW

P2
kW

Q
HP

m3/h

l/min

50

100 150 200 250 300 350 400 450 500

10

9,5

8,8

6,7

12

11,6

11

10,2

7,5

5,5

3,2

14

13,5 12,8

10,8 9,3

7,5

5,5

12

18

15

21

24

27

30

1,2

GQRM 10-10
GQRM 10 32-10

3,1 12,5 450

2,4

1,4

GQRM 10-12
GQRM 10 32-12

3,6

16

450

0,55 0,75

GQR 10-14
GQR 10 32-14

2,8

1,6

GQRM 10-14
GQRM 10 32-14

4,6

16

450

0,75

GQR 10-16
GQR 10 32-16

2,3

GQRM 10-16
GQRM 10 32-16

25

450

1,3

0,9

1,2

16

15,5

15

14,2 13,2 11,8 10,2

5,5

2,3

GQR 10-18
GQR 10 32-18

4,8

2,8

GQRM 10-18
GQRM 10 32-18

30

450

1,7

1,1

1,5

18

17,5

17

16,2

4,3

1,5

GQR 10-20
GQR 10 32-20

6,6

3,8

GQRM 10-20
GQRM 10 32-20

12

35

450

2,2

1,5

20

19,5 18,8

5,7

P1 Max. power input.

0,7 0,45 0,6

12

Hm

Density = 1000 kg/m3.

P2 Rated motor power output.

18

15

13,7 11,8

16,8 15,2 13,2 10,8 8,4

Kinematic viscosity = max 20 mm2/sec.

Dimensions and weights

h min

fM

Off

62

90

h min

G1 1/2
ISO 228

h max

fM

Off

h max

On

On

4.93.432

10

G1 1/2
ISO 228

247

90

4.93.581

245

120

190

190

DN 32
PN 6

10

430

430

mm

TYPE

kg (1)

mm

TYPE

fM

h max

h min

GQR

GQRM

GQR(M) 10-10

390

410

205

14

15

GQR(M) 10-12

405

425

220

14,5

GQR(M) 10-14

405

425

220

GQR(M) 10-16

430

450

GQR(M) 10-18

450

GQR

10-20

GQRM 10-20

kg (1)

fM

h max

h min

GQR

GQRM

GQR(M) 10 32-10

395

415

210

14,7

15,7

15,5

GQR(M) 10 32-12

410

430

225

15,2

16,2

14,5

15,5

GQR(M) 10 32-14

410

430

225

15,2

16,2

245

16

18

GQR(M) 10 32-16

435

455

250

16,7

18,7

470

265

17,5

19

GQR(M) 10 32-18

455

475

270

18,2

19,7

450

470

265

19

GQR

10 32-20

455

475

270

19,7

480

500

295

20,5

GQRM 10 32-20

485

505

300

21,2

1) With cable length: 10 m

1) With cable length: 10 m

234

GQR

Submersible Drainage Pumps

Installation examples
500 min
285

12
86

52

190

On

TYPE

22

h min

80

h max

Off

72

134

176

G2 ISO 228

3/4"

mm
h max h min

GQR(M) 10 32-10

487

282

GQR(M) 10 32-12

502

297

GQR(M) 10 32-14

502

297

GQR(M) 10 32-16

527

322

GQR(M) 10 32-18

547

342

GQR

10 32-20

547

342

GQRM 10 32-20

577

372
3.93.037/3

min 500 x 500

4.93.581/1

Installation examples with vertical magnetic float switch

430 max
380
138

TYPE

h
max

GQRM 10-10 GF

225

315

GQRM 10-12 GF

240

330

GQRM 10-14 GF

240

330

GQRM 10-16 GF

265

355

GQRM 10-18 GF

285

375

On
16
88
100

100

132

360 min

Off
h
min

110
166

h
max

mm
h
min

3.93.037/3

min 300 x 250

Installation examples

30

235

GQR

Submersible Drainage Pumps

Features
PATENTED
Cable length 10 m, pump single-phase
with plug

Handle in polypropylene, with


frame in stainless steel.

Easy adjustment of the float switch:


to allow the adjustement of start/stop
pump levels.

Easy inspection of the capacitor area.

Ring against accidental


extraction of the cable.

The double shaft seal with oil chamber


separates the motor from the water
and provides further protection against
accidental operation when dry.

Relief valve: the pump is fitted to a relief


valve for air release around the impeller
granting a proper pump priming also
after long standstill periods.

G 1 1/2 vertical, upward delivery port


for installation in small pits, without
the need for an elbow on the pump.

Chamber with food/pharmaceutical machinery oil

Shaft in chrome-nickel stainless steel.

Suction strainer with a double row of holes,


for extra safety against clogging: it allows
the passage of solids up to 10 mm.
Pump casing with epoxy cataphoresis
treatment joined to the external paint for
a greater protection against the rust.

Impeller with epoxy cataphoresis treatment for a


greater protection against the rust.

Maximum flexibility of connection:


- Flange DN 32 PN 6 EN 1092-2 for duck
foot coupling SA-G2
- G1 1/2 ISO 228

GQR .. 32
236

09/2016

GXC , GXV

Submersible Sewage and Drainage Pumps


Construction

PATENTED

Single-impeller submersible pumps in chrome-nickel stainless


steel, with vertical delivery port.
GXC: with two-passage impeller.
GXV: with free-flow (vortex) impeller.
Double shaft seal with interposed oil chamber.

Applications
For clean and dirty water, also containing solids up to 35 mm
grain size.
The GXV free-flow impeller construction is particularly suitable
for liquids with a high solid content or with filamentous particles.
This construction (with smooth surfaces in rolled-stainless steel
and easy access for cleaning) is also suitable for certain uses in
the food industry.

Operating conditions
Liquid temperature up to 35 C.
Minimum immersion depth: 250 mm.
Maximum immersion depth: 5 m.
Continuous duty (with submerged motor).

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
GXC, GXV: three-phase 230 V 10%;
three-phase 400 V 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GXCM, GXVM: single-phase 230 V 10%,
with float switch and thermal protector.
Incorporated capacitor.
Cable: H07RN-F, 3G1 mm2, length 10 m, with
plug CEI-UNEL 47166.
Insulation class F.
Protection IP X8 (for continuous immersion)
Triple impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Component
Pump casing
Casing cover
Impeller
Motor jacket
Jacket cover

Material

Handle

Polypropylene (with frame in AISI 304)

Shaft

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Mechanical seal: upper


lower

Ceramic alumina/Carbon/NBR

Seal lubrication oil

Oil for food/pharmaceutical machinery

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Other features on request


- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Other mechanical seal. - Cable length 20 m.
- Motor suitable for operation with frequency converter.
- Three-phase pumps with incorporated float switch.

Characteristic curves n 2900 rpm


U.S. g.p.m.

40

60

80

100

U.S. g.p.m.

120

30

40

50

60

70

80

90

100

10

14

30
40

12

m
10

ft

GX
8

GX

C4

0-1

30

C4

0-1

ft

H
m
6

GX

GX

0-7

V4
0
0-8 -9

20

V4

V4

GX

20
4
10

4
10

0
0

m 3/h

l/min 100

12

18

24

30

200

300

400

500

0
0

m3/h

12

18

24

l/min

100

200

300

400
72.918-N

237

31

GXC , GXV

Submersible Sewage and Drainage Pumps

Performance n 2900 rpm


3~

230V 400V

230V

1~

GXC 40-10

2,8

1,6

GXCM 40-10

4,6

GXC 40-13

2,3

GXCM 40-13

6,6

3~

230V 400V

Capacitor

1~

230V

P2

P1

Vc

kW

16

450

25

450 1,45

Capacitor

kW

Q
HP

0,55 0,75
0,9

P1

Vc

kW

GXV 40-7

2,8

1,6

GXVM 40-7

4,6

16

450

GXV 40-8

3,8

2,2

GXVM 40-8

5,4

25

450

1,1

0,75

GXV 40-9

2,3

GXVM 40-9

25

450

1,3

0,9

1,2

P1 Max. power input.

kW

12

15

18

21

24

26

l/min

50

100

150

200

250

300

350

400

433

10,4

7,1

6,3

5,4

4,4

3,2

9,5

8,7

7,8

6,9

5,9

4,7

Hm

1,2

P2

m3/h

HP

m3/h
l/min

0,55 0,75

Hm

12,9 11,6 10,5

12

15

18

21

24

26

50

100

150

200

250

300

350

400

433

6,2

5,4

4,6

3,7

7,2

6,4

5,5

4,6

3,7

2,8

8,1

7,2

6,3

5,4

4,5

3,5

2,4

Density = 1000 kg/m3.

P2 Rated motor power output.

Kinematic viscosity = max 20 mm2/sec.

Dimensions and weights


On

h min

h max

Off

ISO 228

190

fM

100
G1 1/2

4.93.522

35

103

103

215

405

TYPE

fM

mm
kg(1)
h max h min GXV GXVM

TYPE

fM

mm
kg(1)
h max h min GXC GXCM

GXV(M) 40-7

433

508

248

10,1

11,7

GXC(M) 40-10

433

508

248

10,1

11,7

GXV(M) 40-8

458

533

273

11,7

13,2

GXC(M) 40-13

458

533

273

11,7

13,2

GXV(M) 40-9

458

533

273

11,7

13,2

1) With cable length: 10 m

238

GXC , GXV

Submersible Sewage and Drainage Pumps

Installation examples

Stationary installation

Transportable installation

On

G 1 1/2
ISO 228

Off

3.93.037/3

215
3.93.037/3

min 550 x 550

Connection examples

31

Pump with hosetail seat and


clamp
(locally available)

Pump with pipe screwed into


the delivery port

239

Pump with pipe and union


(locally available)

GXC , GXV

Submersible Sewage and Drainage Pumps

Features
PATENTED

Cable length 10 m, pump single-phase


with plug
Handle in polypropylene, with frame
in stainless steel.

Easy adjustment of the float switch: to


allow the adjustement of start/stop
pump levels.

Easy inspection of the capacitor area.

Ring against accidental extraction


of the cable.
The double shaft seal with oil
chamber separates the motor from
the water and provides further protection against accidental operation when dry.
G 1 1/2 vertical, upward delivery port
for installation in small pits, without
the need for an elbow on the pump.

Totally in stainless steel


All parts in contact with the pumped
liquid both internal and external are
in stainless steel AISI 304

Chamber with food/pharmaceutical


machinery oil.

GXC
GXC The two-passage impeller
costruction is particulary suitable
for liquids containing solids up to 35
mm grain size.

GXV

Shaft in chrome-nickel stainless


steel.

240

GXV The free-fow impeller (vortex)


construction is particularly suitable
for liquids with a high solid content
up to 35 mm grain size or with filamentous particles.

09/2016

GQS , GQV

Submersible Sewage and Drainage Pumps


Construction

PATENTED

Single-impeller submersible pumps, with free-flow (vortex) impeller.


GQS: with vertical threaded delivery port (G 2).
GQV: with horizontal flanged and threaded delivery port
(DN 50 - G 2).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.

Applications
For domestic or industrial waste water, dirty water with solids up
to 50 mm grain size, for liquids which are compatible with the
pump materials.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for rainwater
collection.

Operating conditions
Liquid temperature up to 35 C.
pH value: 6-11.
Maximum immersion depth: 5 m.
Minimum immersion depth: 275 mm.
Continuous duty (with submerged motor).

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
GQV, GQS: three-phase 230 V 10%;
three-phase 400 V 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GQVM, GQSM: single-phase 230 V 10%,
with float switch and thermal protector.
Incorporated capacitor.
Cable: H07RN-F, 3G1 mm2, length 10 m, with
plug CEI-UNEL 47166.
Insulation class F.
Protection IP X8 (for continuous immersion)
Triple impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Component

Material

Pump casing
Impeller
Motor jacket
Jacket cover

Cast iron GJL 200 EN 1561

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Casing cover
Handle

Polypropylene (with frame in AISI 304)

Shaft

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Mechanical seal: upper


lower

Ceramic alumina/Carbon/NBR

Seal lubrication oil

Oil for food/pharmaceutical machinery

Other features on request


- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Other mechanical seal. - Cable length 20 m.
- Motor suitable for operation with frequency converter.
- Three-phase pumps with incorporated float switch.

Characteristic curves n 2900 rpm


0 U.S. g.p.m. 20

40

60

80

100

120

140

18

32

H
50

m
14

GQS,

12

GQS
, GQV

10

GQS,
GQV

GQS
, GQV

ft

GQV 5

0-15

40

50-13
50-11

30

50-9
GQS
, GQ
V 50
-8

20

4
10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

241

400

30
500

0
36
600

GQV , GQS

Submersible Sewage and Drainage Pumps

Performance n 2900 rpm


3~

230V 400V

230V Capacitor

1~

Vc

P1

P2

kW

kW

HP

GQS 50-8
GQV 50-8

2,6 1,5

GQSM 50-8
GQVM 50-8

4,3

16

450 0,95 0,55 0,75

GQS 50-9
GQV 50-9

3,1 1,8

GQSM 50-9
GQVM 50-9

4,8

16

450 1,1 0,75

2,3

GQSM 50-11
GQVM 50-11

6,6

25

450 1,45 0,9

1,2

GQS 50-13
5,2
GQV 50-13

GQSM 50-13
GQVM 50-13

8,4

30

450 1,8

1,1

1,5

GQS 50-15
6,9
GQV 50-15

GQSM 50-15
GQVM 50-15

12

35

450 2,2

1,5

GQS 50-11
GQV 50-11

P1 Max. power input.

m3/h

l/min

50

100 150 200 250 300 350 400 450 500 550 600

7,4

6,9

6,3

5,6

4,8

1,8

9,3

8,8

8,3

7,7

6,2

5,3

4,3

3,2

2,2

11

10,5 10

9,3

8,6

7,8

6,2

5,2

4,2

1,8

11

10,3 9,5

8,6

7,7

6,7

5,7

4,5

3,3

15 14,4 13,7 13 12,2 11,3 10,4 9,5

8,5

7,4

6,2

4,8

3,5

Hm

12,8 12,2 11,6

12

Density = 1000 kg/m3.

P2 Rated motor power output.

18

15

21

24

27

33

30

36

Kinematic viscosity = max 20 mm2/sec.

Dimensions and weights

On

On

165
125
G 2 ISO 228
90
150

h max

90

145

h min

50

Off

DN 50

G 2 ISO 228

fM

G2

h min

fM

Off

h max

130

M8

50

50

19

264

94

94

89

89

242

452

TYPE

430

mm

kg (1)

fM

h max

h min

GQS GQSM

GQS(M) 50-8

460

535

275

14,8

15,8

GQS(M) 50-9

460

535

275

15

16

GQS(M) 50-11

485

560

300

15,8

GQS(M) 50-13

505

580

320

18,8

GQS

50-15

505

580

320

20,3

GQSM 50-15

535

610

350

21,8

TYPE

mm

kg (1)

fM

h max

h min

GQV(M) 50-8

460

535

275

15

16

GQV(M) 50-9

460

535

275

15,2

16,2

17,8

GQV(M) 50-11

485

560

300

16

18

20,3

GQV(M) 50-13

505

580

320

19

20,5

GQV

50-15

505

580

320

20,5

GQVM 50-15

535

610

350

22

1) With cable length: 10 m

1) With cable length: 10 m

242

GQV GQVM

GQS , GQV

Submersible Sewage and Drainage Pumps

Installation examples
500 min
284

12
86

52

190

On

3/4"

mm

22

134

45

h min

80

h max

Off

h
max

h
min

GQV(M) 50-8

580

320

GQV(M) 50-9

580

320

GQV(M) 50-11

605

345

GQV(M) 50-13

625

365

50-15

625

365

GQVM 50-15

GQV

655

395

4.93.495
3.93.037/3

min 500 x 500

430 max
380
138

89
94

100

360 min

16

132

176

G2 ISO 228

TYPE

110
166

Pump with threaded ports:


pipes screwed into the ports

Pump with threaded ports:


pipes with union couplings
(locally available)

Pump with DN 50 flanged ports:


pipes with counter-flanges

32

3/730.39.3

243

GQS , GQV

Submersible Sewage and Drainage Pumps

Features
Cable length 10 m, pump single-phase
with plug

PATENTED

Handle in polypropylene, with frame


in stainless steel.

Easy inspection of the capacitor area.


Easy adjustment of the float switch:
to allow the adjustement of start/stop
pump levels.
Ring against accidental extraction
of the cable.
The double shaft seal with oil chamber
separates the motor from the water
and provides further protection against accidental operation when dry.
Relief valve: the pump is fitted to a relief
valve for air release around the impeller
granting a proper pump priming also
after long standstill periods.
Chamber with food/pharmaceutical
machinery oil
Maximum flexibility of connection:
- Flange DN 50 PN 10 EN 1092-2
- N. 4 M8 holes on 90 for duck
foot coupling SA-G2

Impeller with epoxy cataphoresis


treatment for a greater protection
against the rust.

- G 2 ISO 228

Shaft in chrome-nickel stainless steel.

Pump casing with epoxy cataphoresis


treatment joined to the external
paint for a greater protection against
the rust.

GQV

G 2 vertical, upward delivery port for


installation in small pits, without the
need for an elbow on the pump.

GQS

244

The free-fow impeller (vortex)


costruction is particulary suitable
for liquids containing solids up to 50
mm grain size.

09/2016

GMC, GMV

Submersible Sewage and Drainage Pumps


Construction
Close coupled electric submersible pumps.
GMC: with single-channel impeller.
GMV: with free-flow (vortex) impeller.
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.

Applications
For domestic or industrial waste water, dirty water with solids up
to 45 mm grain size for GMC and 50 mm for GMV, for liquids
which are compatible with the pump materials.

Operating conditions
Liquid temperature up to 35 C.
pH value: 6-11.
Maximum immersion depth: 10 m (with suitable cable length).
Continuous duty (with submerged motor).

Motor
2-pole induction, 50 Hz (n 2900 rpm).
GMC,

three-phase 230 V 10%;


three-phase 400 V 10%;
2 built-in thermal protectors to be connected
to a control box.
Cable: 4G1,5 mm2+ 2x0,5 mm2, length 10 m.
GMCM, GMVM: single-phase 230 V 10%.
With float switch, built-in thermal protector
and built-in capacitor.
Cable: H07RN8-F, 3G1,5 mm2, length 10 m,
with plug (CEI - UNEL 47166).

Materials
Component

Material

Pump casing
Casing cover
Impeller
Motor housing
Motor cover
Shaft
Mechanical seal: Upper
Lower
Seal lubrication oil

GMV:

Insulation class F.
Protection IP X8.
Triple impregnation, humidity-proof winding.
Constructed in accordance with: EN 60335-2-41.

Cast iron GJL 200 EN 1561

Chrome steel 1.4016 EN 10088 (AISI 430)


Carbon, ceramic, NBR
Silicon carbide, silicon carbide, NBR
Oil for food machinery and pharmaceutic use

Other features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Motor suitable for operation with frequency converter.

Characteristic curves n 2900 rpm


0

Imp. g.p.m.

50

U.S. g.p.m. 50

100

150

100

150

200

20

Imp. g.p.m.

U.S. g.p.m.

50

100

50

150

100

150

13

60

m
16

GMC

ft

40

10

ft

GMV

30

A
40

12

A
B
6

B
C

20

20

8
4

10

4
2

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

42
700

0
48
800

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

0
42
700
72.868.C

245

33

GMC, GMV

Submersible Sewage and Drainage Pumps

Performance n 2900 rpm


230 V 400 V

3~

Capacitor

230 V

1~

P1

P2

m /h

12

18

24

30

36

42

48

l/min

100

200

300

400

500

600

700

800

12,8

9,5

6,5

15,5 12,5

10

8,5

6,5

11

7,5

5,5

Q
GMC 50CE
GMC 50-65C
GMC 50BE
GMC 50-65B
GMC 50AE
GMC 50-65A

3,3

1,9

4,8

2,7

6,6

3,8

230 V 400 V

3~

Vc

kW

kW

HP

450

1,1

0,75

6,5 12,5x2 450

1,5

1,1

1,5

1,5

A
GMCM 50CE
GMCM 50-65C
GMCM 50BE
GMCM 50-65B

4,5

16

Capacitor

230 V

1~

P1

Hm

17,3 14,5 12,5

P2

m /h

12

18

24

30

31

35

39

l/min

100

200

300

400

500

516

583

650

9,2

3,5

1,5

10,7

9,5

6,5

4,5

2,5

2,3

12,9 11,5

10

8,5

6,5

4,3

2,5

Q
GMV 50CE
GMV 50-65C
GMV 50BE
GMV 50-65B
GMV 50AE
GMV 50-65A

3,3

1,9

4,8

2,7

6,6

3,8

P1 Max. power input.


P2 Rated motor power output.

A
GMVM 50CE
GMVM 50-65C
GMVM 50BE
GMVM 50-65B

Vc

kW

kW

HP

450

1,1

0,75

6,5 12,5x2 450

1,5

1,1

1,5

1,5

4,5

16

Hm

Density = 1000 kg/m3.

H Total head in m.

Kinematic viscosity = max 20 mm2/sec.

Dimensions and weights

145

ISO 228 G 2

18

GMC 45
GMV 50

4.93.107

180

395
155

185

100

400

DN 65

90

M8

500

505

185

GMC 45
GMV 50

kg

kg

GMC 50-65C
GMC 50-65B
GMC 50-65A
GMCM 50-65C
GMCM 50-65B

30
31
32,5
30
31,5

530 max

530 max

315

248

kg

304

118

29
30
31,5
29
30,5

130

GMV 50-65C
GMV 50-65B
GMV 50-65A
GMVM 50-65C
GMVM 50-65B

246

GMV 50CE
GMV 50BE
GMV 50AE
GMVM 50CE
GMVM 50BE

27
28
29,5
27
28,5

GMC 50CE
GMC 50BE
GMC 50AE
GMCM 50CE
GMCM 50BE

28
29
30,5
28
29,5

kg

GMC, GMV

Submersible Sewage and Drainage Pumps

Dimensions with duck foot coupling


78
33

13
500 min
12
52

86

600 min
443

83

346

85

223

319

100

2"
3/4"
180

117

575
255
68

34

220

253

540

EN 1092-2
PN 10

200
92

120

100

92

198

16

110
166
18
440

531

138

530 max
360 min

130

18

185

145

118

530 max
360 min

118

180

130

132

176

22

134

G2 ISO 228

DN 65
80

33

247

GMC, GMV

Submersible Sewage and Drainage Pumps

Features

GMV

GMC

Safety
The double mechanical seal with oil chamber ensures safe separation separating the motor from water and providing further protection against accidental
operation when dry.

Reliable
The lower double ball bearing ensures high reliability under all operating conditions.

Protection
The three-phase motors are equipped with integrated thermistors, which provide the motor with thermal protection. The motor cable is pre-wired to enable the
user to connect directly to a control panel, providing easier installation.

Flexible installation
The availability of the pump casing with horizontal or vertical flanged ports allows
the installation of pumps in all pits and wells, both small and large sizes.
Installation is also possible with a duck foot coupling.

248

09/2016

GQG

Submersible pumps with high power grinder


Construction

PATENTED

Submersible pumps with high power grinder, with horizontal


flanged and threaded delivery port (DN 32 PN 6 - G 1 1/2).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.

Applications
Suitable for pumping waste water containing long filamentous,
paper and textile materials and organics.
They are particularly suitable for use in domestic, residential and
industrial installations.
Solid passage 6 mm

Operating conditions
Liquid temperature up to 35 C.
Maximum immersion depth: 5 m.
Minimum immersion depth: 300 mm.
Continuous duty (with submerged motor).

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
GQG: three-phase 230 V 10%;
three-phase 400 V 10%;.
GQGM:single-phase 230 V 10%,
with float switch, thermal protection and control box with
starting capacitors.
Cable: H07RN8-F, 4G1 mm2 (4G1,5 mm2 for GMGM 6-25),
length 10 m.
Insulation class F.
Protection IP X8 (for continuous immersion)
Triple impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Component

Material

Pump casing
Impeller

Cast iron GJL 200 EN 1561

Casing cover
Coltello rotante
Coltello fisso

Nickel-Molybdenum steel 1.4125 EN 10088 (AISI 440C)

Motor jacket
Jacket cover

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Other features on request

Handle

Polypropylene (with frame in AISI 304)

Shaft

Chrome-nickel steel 1.4305 EN 10088 (AISI 303)

Mechanical seal: upper


lower

Ceramic alumina/Carbon/NBR

Seal lubrication oil

Oil for food/pharmaceutical machinery

- Other voltages.
- Frequency 60 Hz.
- Other mechanical seal.
- Cable length 20 m.
- Vertical magnetic float switch.
- Three-phase pumps with incorporated float switch.

Characteristic curves n 2900 rpm


0 U.S. g.p.m. 10

20

30

40

50

60

70

30
90

GQG
80

6-25

70
20

6-21

6-18

60
m

50
ft
40

10
30
20
10
0
0
0

m3/h

Q l/min

5
50

10
100

150

200

249

15

18

250

300

34

GQG

Submersible pumps with high power grinder

Performance n 2900 rpm


3~

230V 400V

Capacitor
230V Capacitor

1~

P1

Vc

kW

kW

HP

30+80 450

1,3

0,9

1,2

7,5 30+80 450

1,5

1,1

1,5

1,5

GQG 6-18

2,3

GQGM 6-18

GQG 6-21

4,8

2,8

GQGM 6-21

GQG 6-25

6,6

3,8

GQGM 6-25

9,5 30+80 450

P1 Max. power input.

P2

m3/h

12

13,2

15

16,8

l/min

50

100

150

200

220

250

280

18

16,5

14,5

11,2

6,5

4,5

21

19,2

17

13,5

25

23

20,5

17

13

11

7,8

Hm

Density = 1000 kg/m .

Kinematic viscosity = max 20 mm /sec.

P2 Rated motor power output.

Dimensions and weights

16

65

300 min

Off

560 max

485

On

4.93.436

G1 1/2 ISO 228

255
160

90
120

190

DN 32 PN6

GQGM
Control with box starting capacitors
216

18,5 19,5

GQG(M) 6-21

18,7 19,7

GQG(M) 6-25

19

20

P462+

GQG GQGM

GQG(M) 6-18

219

TYPE

111

kg

made in italy

4.93.596

250

GQG

Submersible pumps with high power grinder

Installation example

12
86

52

500 min
313
218

On

368 min

Off

628 max

22

68.5

80

176
134

G2 ISO 228

3/4"

4.93.436/2

430 max
393
138

110

360 min

98.5 91.5

38

100

132

16

166

34

251

GQG

Submersible pumps with high power grinder

Features

PATENTED

Cable length 10 m.

Handle in polypropylene, with frame in


stainless steel.

Easy adjustment of the float switch: to


allow the adjustement of start/stop pump
levels.

Ring against accidental extraction of the cable.

Relief valve: the pump is fitted to a relief valve for


air release around the impeller granting a proper
pump priming also after long standstill periods.

The double shaft seal with oil chamber


separates the motor from the water and
provides further protection against
accidental operation when dry.

Chamber with food/pharmaceutical


machinery oil.

Maximum flexibility of connection:


- Flange DN 32 PN 6 EN 1092-2
- G 1 1/2 ISO 228
- for duck foot coupling SA-G2

Impeller with epoxy cataphoresis


treatment for a greater protection
against the rust.

Shaft in chrome-nickel stainless steel.


Pump casing and casing cover with epoxy
cataphoresis treatment joined to the external
paint for a greater protection against the rust.

Cutting system made of HRC 60 hardness AISI 440C


stainless steel.

252

09/2016

GM
Submersible Pumps

35

253

GM

Submersible Pumps

GMV

Submersible pumps with vortex impeller in cast iron EN-GJL-250

pag. 256

Submersible pumps with vortex impeller in cast iron with polyurethane coating

pag. 263

Submersible pumps with single channel impeller in cast iron EN-GJL-250

pag. 265

Submersible pumps with channels impeller in cast iron EN-GJL-250

pag. 274

Submersible pumps with grinder in cast iron EN-GJL-250

pag. 288

Submersible pumps with vortex impeller in stainless steel AISI316

pag. 292

Submersible pumps with single channel impeller in stainless steel AISI316

pag. 292

Submersible pumps with channels impeller in stainless steel AISI316

pag. 292

Submersible pumps with vortex impeller in Marine Bronze B10

pag. 303

Submersible pumps with single channel impeller in Marine Bronze B10

pag. 303

Submersible pumps with channels impeller in Marine Bronze B10

pag. 303

GMVS

GMC

GMN

GMG

I-GMV

I-GMC

I-GMN

B-GMV

B-GMC

B-GMN

254

GM

Submersible Pumps

A new series of submersible pumps with high efficiency


hydraulics designed to move slurry, sewage and industrial
process fluids.
The range covers a wide field of use with head up to 75 m And
flows up to 2300 m3/h, with a maximum solid passage up to
140 mm keeping the risk of blockage to a minimum.
Dimensionally designed for heavy demand, even on critical
applications.

Pump designation
B-GM V 4 M 50-80 A
Version B = bronze
I = stainless steel
(no indication: cast iron version)
Series
Impeller type V = Vortex
C = Singlechannel
N = Channels
G = Grinder

Explosion proof version on request.

4-6-8 poles motor (no indication: 2 poles)


Singlephase M (no indication: threephase)
Free passage
Discharge diameter in mm
Pump size

Coverage chart
80

70

60

H
m

GMC

50

40

GMV

GMN

30

35

20
GMC4
10
GMV4

0
5

m 3/h

10

20

30

40 50

100

200

500

1000

72.2000

2000

3000

Tolerances according to UNI EN ISO 9906:2012

255

GMV

Submersible pumps
with vortex impeller
Construction
Submersible pumps with vortex impeller.
Twin mechanical seal with oil chamber.
Delivery connection DN 80-100-150.

Applications
Suitable to pump slurry and sewage waters with the presence of
solid and filamentous parts in suspension, they are in particular
pointed out for emptying sceptic tanks in the domestic, residential and industrial installations.
Solid passage diameter from 50 to 100 mm.

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
2 or 4 poles induction, 50Hz
Three-phase version: 400V 10%, up to 3,2 kW
400/690V 10%, over 3,2 kW
Insulation Class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.

Main materials
Pump casing: cast iron EN-GJL-250
Impeller: cast iron EN-GJL-250+Ni
Motor casing: cast iron EN-GJL-250
Motor cover: cast iron EN-GJL-250
Shaft: stainless steel AISI 420B
Mechanical seal motor side: graphite/ceramic
Mechanical seal pump side: silicon carbite/silicon carbite

Coverage chart
100

GMV

50
40

GMV 50-80

30

GMV 80-80

20

H
m

GMV4
100-150

GMV4 90-100

10

GMV4
80-100

GMV4 65-80

5
4

72.2001

3
2
5

Q m3/h

10

15

20

30

40

50

256

100

150

200

300

400

500

GMV

Submersible pumps
with vortex impeller

Technical data
Power Supply

TYPE

Starting

GMV 50-80F/A
GMV 50-80E/A
GMV 50-80D/A
GMV 50-80C/A
GMV 50-80B/A
GMV 50-80A/A
GMV 70-80B/B
GMV 70-80A/B
GMV 80-80B/A
GMV 80-80A/A
GMV 80-80S/A

P2
kW
3,1
3,9
5
5,7
16,6
18,2
8,2
9
14,9
18,2
22,4

IN
A
5,8
7,2
9,1
10,4
29,8
32,6
14,7
16,2
26,8
32,6
38,9

3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

1/min
r.p.m.
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850

GMV4 65-80D/A
GMV4 65-80C/A
GMV4 65-80B/A
GMV4 65-80A/A
GMV4 90-100B/A
GMV4 90-100A/A
GMV4 80-100C/A
GMV4 80-100B/A
GMV4 80-100A/A
GMV4 80-100S/A
GMV4 100-150E/A

2,3
3,2
3,5
4,9
6
7,5
10
12,9
16
27
27

4,4
6,2
6,8
9,9
11,5
14,3
19
24,1
29,7
49,6
49,6

3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450

P2 Rated power output

IN Rated current

Standard

D.O.L.
D.O.L.

D.O.L.
D.O.L.

Free
passage

Thermal
protector

Humidity
probe

DN
mm
80
80
80
80
80
80
80
80
80
80
80

50
50
50
50
50
50
70
70
80
80
80

NO
NO

NO
NO

80
80
80
80
100
100
100
100
100
100
150

65
65
65
65
90
90
80
80
80
80
100

NO
NO

NO
NO

ATEX
Eex

ATEX Eex Version on demand

35

257

GMV

Submersible pumps
with vortex impeller

Characteristic curves
0

U.S. g.p.m.

0 Imp. g.p.m.

150
100

200
150

250

300

200

350

250

400

300

U.S. g.p.m.

0 Imp. g.p.m.

350

25

150
100

250

200
150

n 2850 1/min

350

n 2850 1/min

45

140

ft

40

40

H
m

15

E
F

10

400

300

GMV 50-80
60

H
m

350

160

GMV 50-80
C

250

50

80

20

300

200

ft
120

35

20
5

100

30

0
0

m 3/h
Q l/min

20

40

500

80

60
1000

25
0
0
50

0
100

1500

40

m 3/h
Q l/min

20

500

40

10

100

30

C
D

E
F

1500

30
%
20

80

60
1000

20
10
0

0
8

20

6
P2
4
kW
2
0

E
F
0
0

m 3/h
Q l/min

20

40

500

80

60
1000

15
P2
10
kW
5

100

1500

0
0

m 3/h
Q l/min

20

500

40

80

60
1000

1500

U.S. g.p.m.

Imp. g.p.m.

200

300
200

400

500

300

400

100
72.2008

72.2007

U.S. g.p.m.

600

500

0 Imp. g.p.m.

150
100

200
150

250

300

200

250

350

400

300

350

30

15
H

GMV4 65-80

n 1450 1/min

H
40

GMV 70-80
n 2850 1/min

80

A
20

10
ft

ft

0
0

m3/h
Q l/min

50

10

100

1000

60
50
%
30
20
10
0
6
5
P2
kW
3
2
1
0

40

20

B
D

0
150

2000

14
12
P2
kW
8
6
4
2

0
0

m3/h
Q l/min

50

1000

C
100

2000

m 3/h
Q l/min

20

500

40

60
1000

60
50
%
30
20
10
0

B
D

0
0

150
72.2009

80

1500

0
100

A
B

A
B
0
0

m 3/h
Q l/min

20

500

40

60
1000

80

1500

100
72.2009

258

GMV

Submersible pumps
with vortex impeller

Characteristic curves
0

U.S. g.p.m.

0
50

Imp. g.p.m.

200

300
200

400

600

500
400

300

500

U.S. g.p.m.

0 Imp. g.p.m.

160

300

200

500

400
300

400

700

800

600

500

700

20
60

GMV4 90-100

GMV 80-80

n 1450 1/min

n 2850 1/min

40

600

S
A
30

120

15

ft

H
m

80

10

40

ft

A
B

40

H
m
20

20

10

0
0

50

m3/h
Q l/min

100

1000

0
150

2000

40

m3/h
Q l/min

100

50
1000

150

2000

0
200

3000

60

30
%
20

40

10
0

25

20
P2
15
kW
10

A
B
0
0

50

m3/h
Q l/min

100

1000

%
20

0
0

150

2000

9
8
P2
6
kW
4
3
2

A
B

0
0

m3/h
Q l/min

100

50
1000

2000

150

0 U.S. g.p.m.

500

0 Imp. g.p.m.

72.2011

1000
500

0
1000
80

600

400

800
600

1000
800

1200

1400

1000

1200

1600
1400

40

GMV4 80-100

120

GMV4 100-150

n 1450 1/min

20

n 1450 1/min

A
B

60

30

ft

ft

H
m

80

40

20

20

10

15
H
m

U.S. g.p.m.

0 Imp. g.p.m.

25

200

3000

72.2010

10
40

0 Q m 3/h 50
l/min 1000
0

100

2000

150

3000

200

250
4000

0
300
5000

80

50

60
%
40

m3/h
Q l/min

100
2000

200

4000

300

6000

0
400

40

20

20
10

32

24
P2
16
kW
8
0

0
0

C
0 Q m 3/h 50
l/min
0
1000

100

2000

150

3000

200

A
B
250
4000

300
5000

35
30
P2
kW
15
10
5
0

72.2012

0
0

m3/h
Q l/min

100
2000

200

4000

300

6000

400
72.2013

259

35

GMV

Submersible pumps
with vortex impeller

Dimensions and weights


13

GMV 50-80
GMV 80-80
GMV4 65-80

d1 min.

78

83

d2

33

85

d3

100

180

116

DN 80
PN 10

370
256

fM
DN2

200

HL

hf
a
HL minimum submersible level

70-80
80-80

h1

250
100

20

160

100

210

DN1
h2

GMV

210

50-80

GMV4
65-80

160

GMV

18
d4
131

110
75

412 min

l1

g2

l2

n3

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMV 50-80F/A
GMV 50-80E/A
GMV 50-80D/A
GMV 50-80C/A
GMV 50-80B/A
GMV 50-80A/A
GMV 70-80B/B
GMV 70-80A/B
GMV 80-80B/A
GMV 80-80A/A
GMV 80-80S/A
GMV4 65-80D/A
GMV4 65-80C/A
GMV4 65-80B/A
GMV4 65-80A/A

Version with duck foot coupling

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

80

80

487

347

116

84

149

149

660

541

392

821

149

246

364

140

62

80

80

553

375

116

84

149

149

660

541

392

821

149

246

364

140

76

80

80

867

516

122

78

164

164

800

593

428

873

185

241

500

150

196

80

80

829

500

65

135

167

167

800

633

446

913

185

280

400

140

165

100

80

900

548

60

140

169

175

900

671

481

950

190

315

400

140

193

100

80

1328

658

58

142

193

193

800

672

483

952

193

316

500

150

320

80

80

516

380

80

121

143

169

700

548

396

828

152

250

364

140

64

80

80

582

400

80

121

143

169

700

548

396

828

152

250

364

140

79

260

GMV

Submersible pumps
with vortex impeller

Dimensions and weights

GMV4 90-100
GMV4 80-100

13
78
83

d1 min.
33

d2
d3

85

100

190
fM

116

DN 100
PN 10

HL

GMV4
90-100

GMV4
80-100

400

a
HL minimum submersible level

DN1
h2

hf

266

220

DN2

h1

250
100

160
210

20

210
160

100

18
d4
131
140

l1

g2

l2

550 min

100

35

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMV4 90-100B/A
GMV4 90-100A/A
GMV4 80-100C/A
GMV4 80-100B/A
GMV4 80-100A/A
GMV4 80-100S/A

Dimensions
Dimensioni
- Dimensions
mmmm

EN 1092-2
PN 10
DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

125

100

829

490

89

111

180

180

800

633

443

933

241

277

500

150

165

125

100

921

570

54

147

189

212

800

640

445

940

195

279

500

150

205

125

100

1343

670

54

146

193

212

800

640

441

936

200

280

500

150

325

261

GMV

Submersible pumps
with vortex impeller

Dimensions and weights

GMV4 100-150

13
78
83

d1 min.
33

d2
d3

85

100

222

DN 150

116

PN 10

fM
DN2
538

383

hf

HL minimum submersible level

DN1
h2

h1
300
100

200

20

200

250

100

250

285

HL

18

d4
131

205

l1

g2

l2

740 min

150

600

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMV4 100-150E/A

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1
150

DN2
150

fM
1359

HL
710

hf
114

a
146

l1
193

262

l2
223

d1
850

d2
675

d3
d4
469 1040

h1
206

h2
280

n3
600

Peso
Weight
kg
g2
225
355

GMVS

Submersible pumps vortex


with polyurethane coated hydraulic parts
Construction
Submersible pumps with vortex impeller
Impeller in Polyurethane with a stainless steel core - Pump
casing in Cast iron EN-GJL-250, with polyurethane coating for
parts subject to high wear.
Twin mechanical seal with oil chamber.
Delivery connection DN 80.

Applications
The pumps are designed to suit applications in plants with an
high sand presence, in marble work companies, in the ceramic
industry, crystals machining or industrial processes handling
abrasives liquids.
Solid passage diameter from 35 mm.

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
2 or 4 poles induction, 50Hz
Three-phase version: 400/690V 10%
Insulation Class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.

Main materials
Pump casing: cast iron EN-GJL-250 with polyurethane coating
Impeller: Polyurethane with a stainless steel core
Motor casing: cast iron EN-GJL-250
Motor cover: cast iron EN-GJL-250
Shaft: stainless steel AISI 420B
Mechanical seal motor side: graphite/ceramic
Mechanical seal pump side: silicon carbite/silicon carbite

Coverage chart
70
60

GMVS 35-80A

50

GMVS 35-80B
GMVS 35-80C
GMVS 35-80D

40

GMVS

GMVS 35-80E
GMVS 35-80F

30

GMVS 35-80G

35

GMVS 35-80H

20

GMVS4 35-80A

10

5
4
3

m 3/h

10

20

50

263

100

150

200

GMVS

Submersible pumps vortex


with polyurethane coated hydraulic parts

Technical data
Power Supply

TYPE

IN
A
16,2
24,7
29,8
29,8
29,8
29,8
29,8
29,8
11,5

P2
kW
9
12
16,6
16,6
16,6
16,6
16,6
16,6
6

GMVS 35-80H/A
GMVS 35-80G/A
GMVS 35-80F/A
GMVS 35-80E/A
GMVS 35-80D/A
GMVS 35-80C/A
GMVS 35-80B/A
GMVS 35-80A/A
GMVS4 35-80A/A
P2 Rated power output

Starting

1/min
r.p.m.
2850
2850
2850
2850
2850
2850
2850
2850
1450

3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

IN Rated current

Free
passage

DN
mm
80
80
80
80
80
80
80
80
80

Standard

Thermal
protector

Humidity
probe

ATEX
Eex

mm
35
35
35
35
35
35
35
35
35

ATEX Eex Version on demand

Dimensions and weights


d1 min.

GMVS 35-80
GMVS4 35-80

d2

13
83

33

HL

DN2

78

fM

200

d3

85

180

100

116

DN 80

PN 10

DN1

370

h1

100

110

250
100

hf

256

h2

20

d4

18

l1
l2

400 min

210
160

75

160
210

131

g2
n3

TIPO
TYPE
TYPE
GMVS 35-80H/A
GMVS 35-80G/A
GMVS 35-80F/A
GMVS 35-80E/A
GMVS 35-80D/A
GMVS 35-80C/A
GMVS 35-80B/A
GMVS 35-80A/A
GMVS4 35-80A/A

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1
80

DN2
80

fM
796

HL
468

hf
122

a
78

l1
165

l2
165

d1
800

d2
593

d3
408

d4
873

h1
185

h2
242

n3
400

Peso
Weight
kg
g2
140
165

80

80

867

514

124

100

165

165

800

593

408

873

185

242

500

150

191

80

80

796

468

122

78

165

165

800

593

408

873

185

242

400

140

160

264

GMC

Submersible pumps
with single channel impeller
Construction
Submersible pumps with single channel impeller.
Twin mechanical seal with oil chamber (lip-seal motor side up to
1,4 kW).
Delivery connection DN 50-65-80-100-150

Applications
Suitable to pump slurry, sewage, waste water (non-corrosive).
In industrial and residential installations and drainag applications
Solid passage from 40 to 100mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
2 or 4 poles induction, 50Hz
Single-phase version: 230V 10%, with float switch and built-in
capacitor.
Three-phase version: 400V 10%, up to 3,2 kW
400/690V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.

Main materials
Pump casing: cast iron EN-GJL-250 - Impeller: cast iron EN-GJL-250+Ni
Motor casing, Motor cover: cast iron EN-GJL-250
Motor shaft: stainless steel AISI 420B
Lip seal made of nitrile up to 1,4 kW
Mechanical seal motor side: graphite/ceramic over 1,4 kW
Mechanical seal pump side: silicon carbite/silicon carbite

Coverage chart
100

GMC

50
40
30

GMC 40-80

35

20

GMC4 90-100

GMC4 80-100

10

GMC 30-50

GMC4
100-150

GMC 40-65

GMC4 65-80

72.2002

3
2
5

Q m3/h

10

15

20

30

40

50

265

100

150

200

300

400

500

GMC

Submersible pumps
with single channel impeller

Technical data
Power Supply

TYPE

GMCM 30-50B/A
GMC 30-50B/A
GMC 30-50A/A
GMCM 40-65B/A
GMC 40-65B/A
GMC 40-65A/A
GMC 40-80D/A
GMC 40-80C/A
GMC 40-80B/A
GMC 40-80A/A
GMC4M 65-80C/A
GMC4 65-80C/A
GMC4 65-80B/A
GMC4 65-80A/A
GMC4 75-80A/A
GMC4 80-100C/A
GMC4 80-100B/A
GMC4 80-100A/A
GMC4 90-100B/A
GMC4 90-100A/A
GMC4 100-150C/B
GMC4 100-150B/B
GMC4 100-150A/B
P2 Rated power output

P2
kW
1,4
1,9
1,9
1,9
2,4
2,4
13,8
13,8
16,6
18,2

IN
A
8,4
3,5
3,5
11,4
4,5
4,5
24,8
24,8
29,8
32,6

1,2
6,9
1,6
3,1
2,3
4,4
2,8
5,4
2,8
5,4
3,9
7,9
3,9
7,9
7,1
13,5
19
10
26,7
14,4
12,9
24,1
15
27,8
33,3
17,8
IN Rated current

Starting

1~ 230V
3~ 400V
3~ 400V
1~ 230V
3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

1/min
r.p.m.
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850

1~ 230V
3~ 400V
3~ 400V
3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
Standard

266

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

Free
passage

DN
mm
50
50
50
65
65
65
80
80
80
80

30
30
30
40
40
40
40
40
40
40

80
80
80
80
80
100
100
100
100
100
150
150
150

65
65
65
65
75
80
80
80
90
90
100
100
100

Thermal
protector

Humidity
probe

ATEX
Eex
NO
NO
NO
NO
NO

NO
NO
NO
NO
NO
NO

NO
NO
NO
NO

NO
NO
NO
NO
NO

ATEX Eex Version on demand

GMC

Submersible pumps
with single channel impeller

Characteristic curves
0 U.S. g.p.m. 50

100
50

0 Imp. g.p.m.

150

200

100

150

U.S. g.p.m.

Imp. g.p.m.

100

300
100

200

250

150

200

30

30

GMC 30-50
H
m

GMC 40-65

80

n 2850 1/min

ft

20

80

n 2850 1/min
20

60

60

H
m

A
ft

B 3~
40

40

B 3~

B 1~

10

10

B 1~

20

20

0 Q m 3/h
l/min
0

10

20

30
500

250

40

50
750

60
50

60

40
%
20

20
250

30
500

40

B
B

3~
1~

1,5

B
B

1,0

A
B 1~

10
0

B 3~

A
3~
1~

P2
2
kW

P2
0,5
kW

A
B 3~

B 1~

0 Q m 3/h
l/min
0

10

20

30
500

250

40

50
750

0 Imp. g.p.m.

200

100

300

0 Q m 3/h 10
l/min
0

20
250

30
500

40

50
750

60
1000
72.2015

72.2014

0 U.S. g.p.m. 100

0
60
1000

50
750

30
%

0 Q m 3/h 10
l/min
0

400

200

300

75

GMC 40-80

60

200

n 2850 1/min

B
H
m
40

150

ft
100

35

20
50

0 Q m 3/h
l/min
0

20

40
500

60
1000

60

0
100

80
1500

40
%
20

A
D

0
20

A
15

B
C

P2
10
kW
5

0 Q m 3/h
l/min
0

20

40
500

60
1000

80

100
1500
72.2014

267

GMC

Submersible pumps
with single channel impeller

Characteristic curves
0

U.S. g.p.m.

Imp. g.p.m.

200

300

400

200

500

300

400

20

15

GMC4 65-80

U.S. g.p.m.

600

15

10
H
m

30
ft

800

600

GMC4 80-100
GMC4 75-80

80
-1
00
A

50

n 1450 1/min

ft

-1
00
00 B
C

40

10

0A

30

20

ft

60

-1

-8

80

75

80

1000

800

400

40

n 1450 1/min

H
m

400

Imp. g.p.m.

20
5
10
10

0 Q m 3/h 20
l/min
0

40

60
1000

500

80

0
120
2000

100
1500

70
60
50

80

m3/h
Q l/min 50
1000

100

200

150
2000

3000

0
250
4000

30
%
10
0

%
40

75

-80

80-100A
80
-10
0B

80-100C

20
0

6
5

3
P2
2
kW
1
0

0
0

P2
3
kW

B
C
0 Q m 3/h 20
l/min
0

40

60
1000

500

80

80-100A

100

1
0

120
2000

1500

80-100B
80-100C
75-80A
0
0

m3/h
Q l/min 50
1000

100

200

150
2000

3000

72.2016

72.2015

0
0

U.S. g.p.m.

400

600
400

Imp. g.p.m.

800

1000

600

800

250
4000

1200

0 U.S. g.p.m. 500

1000

0 Imp. g.p.m.

1000

2000

1500
1000

500

1500

35

30

ft

GMC4 90-100

n 1450 1/min

GMC4 100-150

30

n 1450 1/min

80

ft

80

20

60

20

15

100

60

C
15

40

40

10
10
20

20

0
80

0
m3/h
Q l/min
0
1000

2000

3000

0
300
5000

200

100

4000

100
2000

200

4000

300

6000

400

0
500
8000

80

%
40

%
40

A
B

20

20

0
12

20

10
P2
kW
6

16
P2
kW
8

B
C

4
2

0
m3/h
0 Q l/min

0
0
m3/h
Q l/min
0
1000

200

100
2000

3000

4000

0
m3/h
0 Q l/min

300
5000

100
2000

200

4000

300

6000

400

500
8000
72.2018

72.2017

268

GMC

Submersible pumps
with single channel impeller

Dimensions and weights

GMC 30-50

52
12

86

450 min.
307
189

3/4

75

146

118

134

71

176

268

50

28

G 2

475

HL

64

HL minimum submersible level

132
100

13

110
156

90

106 106

116
2

400 min

392

136
16

35
Version with duck foot coupling

Version with 90 elbow

TIPO
TYPE
TYPE
GMCM 30-50B
GMC 30-50B
GMC 30-50A

Peso
Weight
kg
31

269

GMC

Submersible pumps
with single channel impeller

Dimensions and weights

GMC 40-65
13
600 min

78

447

83

85
33

317

100

2
180

117

DN 65

EN 1092-2
PN 10

556

HL

50
180

47

121

253

335

60

HL minimum submersible level

130

200
92

198
120

92

18
720
181
124

2
1/

15

15

96

90

2 1/2

Version with duck foot coupling

Version with 90 elbow

TIPO
TYPE
TYPE
GMCM 40-65B
GMC 40-65B
GMC 40-65A

Peso
Weight
kg
45

270

360 min.

130 130

69

GMC

Submersible pumps
with single channel impeller

Dimensions and weights

GMC
40-80
GMC4M 65-80
GMC4 65-80
GMC4 75-80

13

d1 min.

78
83

d2
33

85

d3

100

180

116

DN 80
200

PN 10

fM

DN2

370
256

GMC
40-80
200

HL

HL minimum submersible level

DN1
h2

GMC4
65-80

h1

250
20

160

100

160

210

100

210

GMC4
75-80

hf
a

18
d4
131

110

a1

g2

a2

412 min

75

35

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMC
40-80D/A
GMC
40-80C/A
GMC
40-80B/A
GMC
40-80A/A
GMC4M 65-80C/A
GMC4 65-80C/A
GMC4 65-80B/A
GMC4 65-80A/A
GMC4 75-80A/A

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

80

80

890

523

85

116

168

168

750

603

416

883

187

250

500

150

195

80

80

533

330

104

100

132

132

658

498

366

775

132

200

364

140

49

80

80

519

360

84

116

136

157

658

511

366

791

145

220

364

140

67

80

80

516

380

80

121

143

169

700

548

396

828

152

250

364

140

67

271

GMC

Submersible pumps
with single channel impeller

Dimensions and weights

GMC4 80-100
GMC4 90-100

13
78
33

83

d1 min.

100

d2
d3

85

190
fM

116

DN 100
PN 10

HL

GMC4
80-100B

HL minimum submersible level

DN1

GMC4
80-100A
90-100B
90-100A

400

h2

hf

266

220

DN2

h1

250
100

160
210

20

210
160

100

18
d4
131

140

l1

g2

l2

550 min

100

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMC4 80-100C/A
GMC4 80-100B/A
GMC4 80-100A/A
GMC4 90-100B/A
GMC4 90-100A/A

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10

Peso
Weight
kg

DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

125

100

597

420

62

138

180

231

850

673

466

973

207

300

500

150

117

125

100

852

520

54

147

189

212

800

640

445

940

195

279

500

150

170

125

100

920

570

54

147

189

212

800

640

445

940

195

279

500

150

204

272

GMC

Submersible pumps
with single channel impeller

Dimensions and weights

GMC4 100-150

13
78
33

83

d1 min.

100

d2
d3

85

222

DN 150

116

PN 10

fM
DN2

hf

HL minimum submersible level

DN1

GMC4
100-150B
100-150A

383

h2

h1
300
100

200

20

200

250

100

250

GMC4
100-150C

538

285

HL

18

d4
131
205

l1

g2

l2

740 min

150

35

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMC4 100-150C/B
GMC4 100-150B/B
GMC4 100-150A/B

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1
150

DN2
fM
HL
150 1013 630

hf
80

a
180

l1
239

l2
304

d1
990

d2
840

d3
566

d4
1122

h1
273

h2
400

n3
225

Peso
Weight
kg
g2
600
313

150

150

80

180

239

304

990

840

566 1208

273

400

225

500

1273 660

273

375

GMN

Submersible pumps
with channels impeller
Construction
Submersible pumps with channels impeller.
Twin mechanical seal with oil chamber.
Delivery connection DN 65-80-100-150-200-250-300.

Applications
Suitable to pump slurry, sewage and waste water (non-corrosive)
with solids in suspension.
For industrial and residential installations and general drainage
applications.
They are ideal for applications with smaller solids.
Solid passage from 30 to 140 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
Main materials

2-4-6 or 8 poles induction, 50Hz


Three-phase version: 400V 10%, up to 3,2 kW
400/690V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.

Pump casing: cast iron EN-GJL-250


Impeller: cast iron EN-GJL-250+Ni
Motor casing: cast iron EN-GJL-250
Motor cover: cast iron EN-GJL-250
Shaft: stainless steel AISI 420B
Mechanical seal motor side: graphite/ceramic
Mechanical seal pump side: silicon carbide/silicon carbide

Coverage chart
100

GMN

50
40

GMN 40-100

30
GMN4 100-250

20

GMN 30-80
GMN4 80-150

GMN4
GMN4
100-150 100-200

m
10
GMN4 80-100

GMN6
100-250
GMN6
100-200

GMN 30-65

5
4
GMN6 80-100

GMN6 80-150

GMN8
100-200

GMN8
100-250 GMN8 140-300

GMN6 140-300
72.2003

3
2
10

m3/h

20

30

40

50

100

150

274

200

300

400 500

1000

1500 2000

3000

GMN

Submersible pumps
with channels impeller

Technical data
Power Supply

TYPE

Starting

GMN 30-65B/A
GMN 30-65A/A
GMN 30-80B/A
GMN 30-80A/A
GMN 30-80S/A
GMN 40-100D/A
GMN 40-100C/A
GMN 40-100B/A
GMN 40-100S/A

P2
kW
3,1
3,6
5
6
7,5
12
14,9
16,6
20

IN
A
5,8
6,6
9,1
10,9
13,5
21,7
26,8
29,8
35,8

3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

1/min
r.p.m.
.
2850
2850
2850
2850
2850
2850
2850
2850
2850

GMN4 80-100D/A
GMN4 80-100C/A
GMN4 80-100A/A

4,6
7,5
10

9,3
14,3
19

3~ 400/690V
3~ 400/690V
3~ 400/690V

1450
1450
1450

GMN6 80-100B/A
GMN6 80-100A/A
GMN6 80-150B/A
GMN6 80-150A/A
GMN6 100-150B/B
GMN6 100-150A/B

2,7
2,8
6
8
14
12

5,8
6
12
15,8
26,2
22,9

3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

950
950
950
950
950
950

GMN4 80-150C/B
GMN4 80-150B/B
GMN4 100-150G/A
GMN4 100-150F/A
GMN4 100-150E/B
GMN4 100-150D/B
GMN4 100-150S/B
GMN4 100-200C/A
GMN4 100-200B/A
GMN4 100-200A/A
GMN4 100-250D/A
GMN4 100-250C/A
GMN4 100-250B/A
GMN4 100-250A/A

27
30
23
27
30
30
35,7
40
48
45
65
75
75
85

49,6
54,3
42,2
49,6
54,3
54,3
63,6
71,3
78,1
85,2
109,7
126,3
126,3
143,2

3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

GMN6 100-200E/B
GMN6 100-200D/B
GMN6 100-250D/A
GMN6 100-250C/A
GMN6 100-250B/A
GMN6 100-250A/A
GMN6 140-300D/A
GMN6 140-300C/A
GMN6 140-300B/A
GMN6 140-300A/A

14
14
23
29
39,2
39,2
33,4
39,2
55,8
65

26,2
26,2
40,6
52,8
71
71
60,8
71
99
115,3

GMN8 100-200B/C
GMN8 100-200A/A
GMN8 100-250B/B
GMN8 100-250A/C
GMN8 140-300A/A

9,3
9,3
12,4
19
26,7

19,8
19,8
26,5
39
53,5

P2 Rated power output

IN Rated current

Free
passage

DN
mm
65
65
80
80
80
100
100
100
100

30
30
30
30
30
40
40
40
40

100
100
100

80
80
80

100
100
150
150
150
150

80
80
80
80
100
100

1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450

150
150
150
150
150
150
150
200
200
200
250
250
250
250

80
80
100
100
100
100
100
100
100
100
100
100
100
100

3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

950
950
950
950
950
950
950
950
950
950

200
200
250
250
250
250
300
300
300
300

100
100
100
100
100
100
140
140
140
140

3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

750
750
750
750
750

200
200
250
250
300

100
100
100
100
140

Standard

275

D.O.L.
D.O.L.

D.O.L.
D.O.L.

Thermal
protector

Humidity
probe

ATEX
Eex
NO
NO

NO
NO

NO
NO

NO
NO

ATEX Eex Version on demand

35

GMN

Submersible pumps
with channels impeller

Characteristic curves
0 U.S. g.p.m.
0

200
100

Imp. g.p.m.

300

400

200

300

20

200

300
200

60

GMN 30-65

U.S. g.p.m.

0 Imp. g.p.m.100
40

600

400

500
120

GMN 30-80
n 2850 1/min

n 2850 1/min

H
m

500

400
300

30

H
m

20

ft
40

10

80

40

20
10

0
0

m3/h
Q l/min

20

500

40

60
1000

80

0
100

1500

80

100

0
8

P2
kW
2

2000

6
P2
kW

0
140

20

A
B

2
0
0

m3/h
Q l/min

20

500

40

60
1000

80

100

1500

72.2019

U.S. g.p.m.

0 Imp. g.p.m. 200

400

600

800
160

GMN 40-100

B
40

600

n 2850 1/min

120

D
30

ft

H
m

80

20

40
10

0
0

m3/h
Q l/min

50
1000

100

2000

150

3000

0
250
4000

200

80

%
40

S
B

20

0
20
P2
kW

S
C B

10

5
0
0

m3/h
Q l/min

50
1000

100

2000

150

3000

200

0
0

m3/h
Q l/min

50

1000

100

2000

140
72.2020

1000

800

400

1000

50

60

20

50

m3/h
Q l/min

80

60

0
0

250
4000
72.2021

276

GMN

Submersible pumps
with channels impeller

Characteristic curves
0 U.S. g.p.m.
0

400
200

Imp. g.p.m.

600

800

400

600

U.S. g.p.m.

800

1200

400

Imp. g.p.m.

800

10
30

GMN6 80-100
H
m

GMN4 80-100

20

n 950 1/min
ft

n 1450 1/min

H
m

60

20

ft

40

5
10

10
20

0
0

m 3/h
Q l/min

50
1000

100

150

2000

0
200

3000

80

0
0

3
m /h
Q l/min

0
100

200

2000

300

4000

80

60

60

A
B

20

20

10

2
P2
kW
1

8
P2
kW
4

C
D

2
0

0
0

m 3/h
Q l/min

50
1000

100

150

2000

200

3000

0
0

3
m /h
Q l/min

100

200

2000

300

4000

72.2023

0 U.S. g.p.m. 400


0

400

Imp. g.p.m.

800

1200

72.2024

0 U.S. g.p.m.

1600

800

1200

50

15

0 Imp. g.p.m.
400

1200

800
800

1600
1200

2400
2000
160

GMN4 80-150

GMN6 80-150
H
m

2000
1600

40

n 950 1/min

n 1450 1/min

40

120

ft

10
30

30

ft

H
m

80

20

20

10

10

5
40

0
0

m3/h
Q l/min

100
2000

200

300

4000

6000

0
400

200

4000

300

6000

400

500
8000

0
600
10000

80

80
60

40

20

20

40
P2
kW

10
8
P2
kW
4

B
C

20

10

2
0

0 Q m3/h 100
l/min 2000
0

0
0

m3/h
Q l/min

100
2000

200

4000

300

6000

400

0 Q m3/h 100
l/min 2000
0

200

4000

300

6000

400

500
8000

600
10000
72.2026

72.2025

277

35

GMN

Submersible pumps
with channels impeller

Characteristic curves
0
25

U.S. g.p.m.

800

0 Imp. g.p.m. 400

1200
800

1600

0 U.S. g.p.m.

2000

1200

0 Imp. g.p.m.
400

1600

GMN6 100-150

H
m

1200

2000

2400
2000

1600

60

30

ft

H
m

40

20

20

10

120

GMN4 100-150

n 950 1/min

15

1600

1200
800

40

80

20

800

n 1450 1/min
ft

D
F
G

80

10
40

0
0

m3/h
Q l/min

100
2000

200

4000

300

6000

0
500
8000

400

80

80

40

0
40
P2
kW

A
B

300

6000

400

0
0

m /h
Q l/min

100
2000

200

4000

300

6000

400

500
8000
72.2027

0
600
10000

S
G

E F

S
E F

10
3

500
8000

20

4
0

4000

20

16
P2
kW
8

200

40

20

0 Q m3/h 100
l/min 2000
0

0 Q m3/h 100
l/min 2000
0

200

4000

300

6000

400

500
8000

600
10000
72.2028

278

GMN

Submersible pumps
with channels impeller

Characteristic curves
0
0

U.S. g.p.m.

1000

Imp. g.p.m. 500

1500

0 U.S. g.p.m.

2500

2000

1000

2000

1500

Imp. g.p.m.

1600
800

2400

3200

1600

2400

20

15

60

GMN6 100-200

GMN8 100-200

H
m

40

n 750 1/min

n 950 1/min

H
m
ft

ft

10

40

E
10

B
20
5

20

0
0

m3/h
Q l/min

200

300
5000

0
600
10000

500

400

200
4000

400

600

8000

12000

0
800

80

80

60
%

20

10

14

8
P2
kW

60

20

12
P2
kW
8

4
2

m3/h
Q l/min

100

100

0
0

6
0
0

m3/h
Q l/min

200

300
5000

500

400

600
10000

0
0

m3/h
Q l/min

200
4000

400

600

8000

12000

72.2030

72.2029

U.S. g.p.m.

0 Imp. g.p.m. 800

1600

2400

3200

4000

2400

1600

800

3200

U.S. g.p.m.

2000

Imp. g.p.m. 1000

3000

5000

4000

2000

4000

3000

15

40

GMN4 100-200

A
B

120

40

n 750 1/min

ft

30

A
10

H
m

GMN8 100-250

H
m

n 1450 1/min

ft

80

20

B
20
5

40
10

35
0
0

m3/h
Q l/min

200
4000

400

8000

600

12000

0
1000
16000

800

80

m 3/h
Q l/min

500

1000

10000

0
20000

100
80

60

40

20

20

50

20

40
P2
kW
20

16
P2
kW

10
0

0
0

0
0

m3/h
Q l/min

200
4000

400

8000

600

12000

800

1000
16000
72.2028

0
0

m 3/h
Q l/min

500

10000

1000

20000
72.2031

279

GMN

Submersible pumps
with channels impeller

Characteristic curves
0
0

U.S. g.p.m.

2000

Imp. g.p.m. 1000

3000

4000

2000

5000

4000

3000

50

30

80

n 950 1/min

20

800

1200

2000

1600

800

1200

1600
160

GMN4 100-250

GMN6 100-250

H
m

U.S. g.p.m.

0 Imp. g.p.m. 400

A
B
C

ft

A
B
C
D

40

40

n 1450 1/min
120

30

ft

H
m

80

20

10
40
10

0
0

m 3/h
Q l/min

500

1000

10000

100

m3/h
Q l/min 5000

500
10000

1000
15000

80

40

20

0
40

20

C
D

A
D

40
500

20

1000

10000

B
C

60

10
m 3/h
Q l/min

0
1500
25000

0
100
P2
kW

30
P2
kW

0
0

20000

A
B
D C

60

0
0

100

80

20000

20000

0
0

m3/h
Q l/min 5000

500
10000

1000
15000

20000

1500
25000
72.2033

72.2032

0 U.S. g.p.m.
0

1600
800

Imp. g.p.m.

2400
1600

3200

2400

U.S. g.p.m.
Imp. g.p.m. 2000

4000

6000

8000

4000

10000

6000

8000

30

20
60

GMN8 140-300

GMN6 140-300

H
m

n 750 1/min

H
m

ft

20

80

n 950 1/min

A
B

40

ft

C
10

D
40
10

20

0
0

m3/h
Q l/min

400
8000

800

16000

1200

24000

0
1600

m 3/h
Q l/min 10000

1000

20000

30000

2000

0
40000

100

100

80

80

60

60

20

20

30

60

B
C

50
P2
kW

P2
20
kW
10

0
0

30
0
0

m3/h
Q l/min

400
8000

800

16000

1200

24000

20

1600

D
0
0

m 3/h
Q l/min 10000

1000

20000

C
30000

2000

40000
72.2034

72.2030

280

GMN

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN 30-65

78
83

d1 min.
d2

33

85
d3

100

180

117

DN 65

253

fM

DN2
185

HL

216

PN 10

hf

a
HL minimum submersible level

DN1
h2

200
92

h1

120

198

92

18

d4
180

100

360 min

62

l1

g2

l2

35

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMN 30-65B/A
GMN 30-65A/A

Dimensions
Dimensioni - Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

80

65

456

300

78

90

133

145

625

495

357

767

138

220

364

140

62

281

GMN

Submersible pumps
with channels impeller

Dimensions and weights

GMN 30-80

13

d1 min.

78
83

d2
33

85

d3

100

180

116

DN 80
PN 10

DN2

370
256

fM

200

HL

hf
a
HL minimum submersible level

h1

250
100

160

20

160

210

100

210

DN1
h2

18
d4
131

110

l1

g2

l2

412 min

75

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMN 30-80B/A
GMN 30-80A/A
GMN 30-80S/A

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

80

80

515

330

110

90

133

145

700

511

366

791

145

220

370

140

75

100

80

767

438

132

68

165

165

700

571

386

851

185

220

500

150

150

282

GMN

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN 40-100
GMN 50-100
GMN4 80-100
GMN6 80-100

78
83

d1 min.
33

d2
d3

85

100

220

190
fM

GMN4 80-100A-C

116

DN 100
PN 10

HL

GMN GMN4 80-100D


40-100 GMN6 80-100

400

a
HL minimum submersible level

DN1
h2

hf

266

220

DN2

h1

250
100

160
210

20

210
160

100

18
d4
140

131

l1

g2

l2

550 min

100

n3

TIPO
TYPE
TYPE
GMN 40-100D/A
GMN 40-100C/A
GMN 40-100B/A
GMN 40-100S/A
GMN4 80-100D/A
GMN4 80-100C/A
GMN4 80-100A/A
GMN6 80-100B/A
GMN6 80-100A/A

35

Version with duck foot coupling

Version with foot and 90 elbow

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

125

100

794

480

127

73

168

184

750

628

441

928

187

275

500

150

206

125
125
125
125

100
100
100
100

73
138
147
147

193
180
189
189

193
231
212
212

800
850
800
800

628
673
640
640

441
466
445
445

928
973
940
940

187
207
195
195

275
300
279
279

500
500
500
500

150
150
150
150

100

570
424
526
570
372
424

127
62
54
54

125

1269
597
852
920
531
597

62

138

180

231

850

673

466

973

207

300

500

150

340
115
175
205
96
114

283

GMN

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN6 80-150
GMN6 100-150
GMN4 80-150
GMN4 100-150

78
33

83

d1 min.

100

d2
d3

85

222

116

DN 150
PN 10

fM
DN2

hf

HL minimum submersible level

DN1
h2

h1
300
100

200

20

200

100

250

GMN6
100-150
GMN4
80-150
GMN4
100-150

383

250

GMN6
80-150

538

285

HL

18

d4

205
150

l1

g2

l2

740 min

131

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
GMN6 80-150B/A
GMN6 80-150A/A
GMN6 100-150B/B
GMN6 100-150A/B
GMN4 80-150C/B
GMN4 80-150B/B
GMN4 100-150G/A
GMN4 100-150F/A
GMN4 100-150E/B
GMN4 100-150D/B
GMN4 100-150S/B

Dimensions
Dimensioni
- Dimensions
mmmm

EN 1092-2
PN 10
DN1

DN2

150

h1

h2

n3

467 1038

206

301

600

Peso
Weight
kg
g2
190
225
220

840

566 1208

273

400

500

225

382

990
990

840
840

566 1208
566 1208

273
273

400
400

500
500

225
225

450
515

304

990

840

566 1208

273

400

500

225

430

304

990

840

566 1208

273

400

500

225

518

HL
540
580

hf

l1

l2

d1

d2

d3

150

fM
820
933

113

147

191

223

850

673

150

150

1274 737

80

180

239

304

990

150
150

150
150

1409 737
1439 742

80
80

180
180

239
239

304
304

150

150

1409 737

80

180

239

150

150

1439 742

80

180

239

284

d4

GMN

Submersible pumps
with channels impeller

Dimensions and weights


13

GMN4 100-200
GMN6 100-200
GMN8 100-200

78
33

83

d1 min.
100

d2
d3

85

fM

116

PN 10

700

461

HL

DN2

HL minimum submersible level

DN1
h2

hf

h1

20
300

400
133

250

300

133

250

340

337

DN 200

20
d4

l1

g2

l2

800 min

110

35

n3

Version with duck foot coupling

Version with foot

TIPOTYPE
TYPE
GMN4 100-200C/A
GMN4 100-200B/A
GMN4 100-200A/A
GMN6 100-200E/B
GMN6 100-200D/B
GMN8 100-200B/C
GMN8 100-200A/A

Dimensions
Dimensioni
- Dimensions
mmmm

EN 1092-2
PN 10
DN1

DN2

200

200

200
200

fM

HL

h1

h2

n3

g2

Peso
Weight
kg

656 1469

306

480

700

265

665

958

656 1314

303

480

700

265

385

958

656 1314

303

480

700

265

435

hf

l1

l2

d1

d2

d3

1613 780

153

198

306

335

1200

962

200

1256 665

153

180

269

336

1200

200

1392 665

153

180

269

335

1200

285

d4

GMN

Submersible pumps
with channels impeller

Dimensions and weights


30

GMN4 100-250
GMN6 100-250
GMN8 100-250

13

190
d1 min.
d2

200

d3

120

275

DN 250
fM

695

435

HL

DN2
395

112

PN 10

HL minimum submersible level

DN1
h2

hf

320

22

h1

365
584

74

d4

l1

g2

l2

1000 min

122

n3

Version with foot

TIPOTYPE
TYPE
GMN4 100-250D
GMN4 100-250C
GMN4 100-250B
GMN4 100-250A
GMN6 100-250D
GMN6 100-250C
GMN6 100-250B
GMN6 100-250A
GMN8 100-250B/A
GMN8 100-250A/B

Version with duck foot coupling

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

250

250

250

fM

HL

h1

h2

n3

g2

Peso
Weight
kg

752 1602

378

600

700

265

914

1400 1130

752 1602

378

600

700

265

530
590

419

1400 1130

752 1602

378

600

700

265

750

419

1400 1130

752 1602

378

600

700

265

520
600

hf

l1

l2

1710 797

250

214

336

419

1400 1130

250

1408
735
1437

250

180

336

419

250

250

1629 800

286

214

336

250

250

1408 735
1437

250

180

336

286

d1

d2

d3

d4

GMN

Submersible pumps
with channels impeller

Dimensions and weights


103

11

11
d1 min.

19

GMN6 140-300

d2
d3

120

125

DN 300
PN 10

437

119

fM

DN2

665

827

445

HL

HL minimum submersible level

DN1
h2

hf

h1

650

500

30

500
795

d4

l1

g2

l2

1000 min

113

n3

TIPOTYPE
TYPE
GMN6 140-300D
GMN6 140-300C
GMN6 140-300B
GMN6 140-300A
GMN8 140-300A

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

350

300

350
350

35

Version with duck foot coupling

Version with foot

fM

HL

h1

h2

n3

g2

Peso
Weight
kg

789 1930

465

600

1248

540

1030

1500 1254

789 1930

465

600

1248

540

1190

1500 1254

789 1930

465

600

1248

540

1024

hf

l1

l2

1959 1127

260

494

465

465

1500 1254

300

2040 1164

260

494

465

465

300

1959 1127

260

494

465

465

287

d1

d2

d3

d4

GMG

Submersible pumps
with high power grinder
Construction
Submersible pumps with high power grinder.
Twin mechanical seal with oil chamber (lip-seal motor side up
to 1,6 kW).
Delivery connection DN 40.

Applications
Suitable for pumping waste water containing long filamentous,
Paper and textile materials and organics.
They are particularly suitable for use in domestic, residential and
industrial installations
Solid passage from 6 and 7 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor
2 poles induction, 50Hz
Single-phase version: 230V 10%, with float switch and control
box with thermal protection and starting capacitors.
Three-phase version: 400V 10%, up to 3,2 kW
400/690V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.

Main materials
Pump casing: cast iron EN-GJL-250
Motor casing: cast iron EN-GJL-250
Motor cover: cast iron EN-GJL-250
Impeller: cast iron GS 400
Shaft : stainless steel AISI 420B
Lip seal made of nitrile up to 1,6 kW
Mechanical seal motor side: graphite/ceramic over 1,6 kW
Mechanical seal pump side: silicon carbide/silicon carbide

Coverage chart
U.S. g.p.m.

20

30

40

60

50

70

80

50
160

GMG 7-40A

GMG

GMG 7-40B

40

GMG 7-40C

120

GMG 7-40D
ft

30

GMG 7-40E

H
m

GMG-GMGM 6-40A

20

GMG-GMGM 6-40B

80

GMGM 6-40C
40

GMGM 6-40D

10

GMGM 6-40E

0
0

m 3/h
l/min

10

5
100

15
200

20
300
72.2004

288

GMG

Submersible pumps
with high power grinder

Technical data
Power Supply

TYPE

GMGM 6-40E/B
GMGM 6-40D/B
GMGM 6-40C/A
GMGM 6-40B/A
GMG 6-40B/A
GMGM 6-40A/A
GMG 6-40A/A
GMG 7-40E/A
GMG 7-40D/A
GMG 7-40C/A
GMG 7-40B/A
GMG 7-40A/A
P2 Rated power output

P2
kW
1,1
1,1
1,1
1,5
1,6
1,9
2,4
3,1
3,1
4,2
5
5

IN
A
6,6
6,6
6,6
9
3,1
11,4
4,5
5,8
5,8
7,7
9,1
9,1

IN Rated current

1~ 230V
1~ 230V
1~ 230V
1~ 230V
3~ 400V
1~ 230V
3~ 400V
3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V

Starting

1/min
r.p.m.
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850
Standard

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

Free
passage

DN
mm
40
40
40
40
40
40
40
40
40
40
40
40

Thermal
protector

Humidity
probe

ATEX
Eex
6
6
6
6
6
6
6
7
7
7
7
7

NO
NO
NO
NO

NO
NO
NO
NO
NO
NO
NO
NO
NO

ATEX Eex Version on demand

35

289

GMG

Submersible pumps
with high power grinder

Characteristic curves
0
0

U.S. g.p.m.
Imp. g.p.m.

30
20

50

40
30

60

40

70

60

50

50
40

n 2850 1/min

70
60

50

GMG 7-40
n 2850 1/min

80

140

ft

H
m

ft

60

160

40

20

40
30

GMGM 6-40

30
20

50

30

H
m

U.S. g.p.m.
Imp. g.p.m.

120

D
100

30

E
40

10

80
20

60

40

0
0

m3/h
Q l/min

10

100

50

40

200

10

15

m3/h
Q l/min

10

100

40

30

A
D

10

2,0

P2
kW
1,0

0,5

E
0
0

m /h
Q l/min
3

100

10

200

A
B
C
D
E

4
P2
kW
2

1
0

10

200

15

20

0
0

15

0
0

m3/h
Q l/min

100

10

200

15
72.2036

72.2035

290

GMG

Submersible pumps
with high power grinder

Dimensions and weights

GMGM 6-40
GMG 6-40
GMG 7-40

52
12

86

d1 min.
d2
d3

3/4

fM
40

75

HL

28

G 2
HL minimum submersible level

176

h1

134

h2

hf

116

l1

100

90

/2

1
1

l2
R6

16

110
136

400 min

d4

Version with duck foot coupling

Version with threaded flange and 90 elbow


Dimensions
Dimensioni
- Dimensions
mm
mm
1

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

Peso
Weight
kg

40

487

246

65

103

122

122

450

297

178

392

118

135

30

40

464

316

72

63

112

112

450

312

194

392

118

150

40

40

451

325

17

117

121

121

450

327

189

413

138

150

52

40

510

353

17

117

121

121

450

334

189

420

147

150

67

TIPO
TYPE
TYPE
GMGM 6-40E/B
GMGM 6-40D/B
GMGM 6-40C/A
GMGM 6-40B/A
GMG 6-40B/A
GMGM 6-40A/A
GMG 6-40A/A
GMG 7-40E/A
GMG 7-40D/A
GMG 7-40C/A
GMG 7-40B/A
GMG 7-40A/A

35

Control box

140

195

To fix the control panel, use the preposed holes


as specify in this drawing.
In order to maintain the protection degree,
suitable fixing devices must be used.

291

I-GM

Submersible pumps

AISI 316
Construction
Submersible pumps in AISI 316 stainless steel.
I-GMV with free-flow (vortex) impeller
I-GMC with single-channel impeller
I-GMN with channels impeller
Twin mechanical seal with oil chamber (lip-seal motor side up to
2,4 kW 2 poles).
Delivery connection DN 50-65-80-100-150

Applications
Suitable to pump aggressive and corrosive liquids, particularly
to drain waste water in industrial and chemical process plants.
Solid passage from 30 to 100 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor

Main materials

2 or 4 poles induction, 50Hz


Three-phase version: 400V 10%, up to 3,2 kW
400/690V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.

Pump casing: stainless steel AISI 316


Motor casing: stainless steel AISI 316
Motor cover: stainless steel AISI 316
Impeller: stainless steel AISI 316
Shaft: stainless steel AISI 316L
Screws: stainless steel AISI 316
Mechanical seal motor side: graphite/ceramic/FPM (lip-seal made of nitrile up to
2,4 kW 2 poles).
Mechanical seal pump side: silicon carbide/silicon carbide/FPM

Coverage chart
100

I-GM

50
40
30

I-GMN
20

H
m

I-GMC

10

I-GMV

72.2006

3
2
2

Q m3/h

10

15

20

30

292

40

50

100

150

200

300

400 500

I-GM

AISI 316

Submersible pumps

Technical data
Power Supply

TYPE

I-GMV 50-50C/A
I-GMV 50-50B/B
I-GMV 50-50A/B

P2
kW
1,8
1,6
2,4

IN
A
3,5
3,1
4,5

I-GMV4 50-65C/A
I-GMV4 50-65B/A
I-GMV4 50-65A/A
I-GMV4 50-80B/A
I-GMV4 50-80A/A

1,1
1,4
1,6
2,3
2,8

I-GMC 40-65B/A
I-GMC 40-65A/A

Starting

3~ 400V
3~ 400V
3~ 400V

1/min
r.p.m.
2850
2850
2850

2,4
2,7
3,1
4,4
5,4

3~ 400V
3~ 400V
3~ 400V
3~ 400V
3~ 400V

2,1
2,8

3,9
6

I-GMN 30-65B/A
I-GMN 30-65A/A
I-GMN 30-80B/A
I-GMN 30-80A/A
I-GMN 30-80S/A
I-GMN 40-100D/A
I-GMN 40-100C/A
I-GMN 40-100B/A
I-GMN 40-100S/A
I-GMN 50-100C/A
I-GMN 50-100B/A
I-GMN 50-100A/A

3,1
3,6
5
6,5
7,5
12
13,8
16,6
20
40
45
52

I-GMN4 60-100B/A
I-GMN4 60-100A/A
I-GMN4 80-100B/A
I-GMN4 80-100A/A
I-GMN4 100-150B/A
I-GMN4 100-150A/A

6
7,1
10
10
23,6
30

P2 Rated power output

Free
passage

Thermal
protector

Humidity
probe

D.O.L.
D.O.L.
D.O.L.

DN
mm
50
50
50

50
50
50

NO
NO
NO

NO
NO
NO

1450
1450
1450
1450
1450

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

65
65
65
80
80

50
50
50
50
50

NO
NO
NO
NO
NO

NO
NO
NO
NO
NO

3~ 400V
3~ 400V

2850
2850

D.O.L.
D.O.L.

65
65

40
40

NO
NO

NO
NO

5,8
6,6
9,1
11,8
13,5
21,7
24,8
29,8
35,8
71
78,3
90,1

3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

2850
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850
2850

D.O.L.
D.O.L.

65
65
80
80
80
100
100
100
100
100
100
100

30
30
30
30
30
40
40
40
40
50
50
50

NO
NO

NO
NO

11,5
13,5
19
19
43,3
54,3

3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V
3~ 400/690V

1450
1450
1450
1450
1450
1450

100
100
100
100
150
150

60
60
80
80
100
100

IN Rated current

Standard

ATEX
Eex

ATEX Eex Version on demand

35

293

I-GM

AISI 316

Submersible pumps

Characteristic curves
0

U.S. g.p.m.

Imp. g.p.m.

50

100

150

50

100

10

15

10

U.S. g.p.m.

80

120
80

Imp. g.p.m.

40

n 2850 1/min

30

H
m

20

200
30

n 1450 1/min

25
ft

ft

240

160

I-GMV4 50-65

H
m

200

160
120

I-GMV 50-50
A

20

C
15
ft

10

3
10

2
5
1

0 Q m3/h
0 l/min 100

10

20
200

300

0
40

30
500

400

600

50

50

40

40

20
10

0 Q m3/h
0 l/min 100

10

20
200

300

30
500

400

m3/h
Q l/min 10
200

20

40

30
400

10

A
B

A
B

1,2

P2
0,8
kW
0,4
0

40
600

0
60
1000

50
800

600

20

2
1,5
P2
1
kW
0,5

0
0

0
0

m3/h
Q l/min 10
200

20

40

30
400

50
800

600

60
1000
72.2038

72.2037

0 U.S. g.p.m. 100


0 Imp. g.p.m.

200

100

300

400

300

200

10

20

80

120
80

200

160

240

160

120

200
60

I-GMC 40-65

n 1450 1/min

n 2850 1/min

ft
H
m

U.S. g.p.m.
Imp. g.p.m.

30

I-GMV4 50-80

50

15

ft

A
20

6
5

H
m

40

10

30

ft

20

10
5

2
10
1
0

0 Q m3/h
l/min
0

20

500

40

60
1000

80

1500

0
100

60

60

m3/h
Q l/min 10
200

20

40

30
400

600

0
60
1000

50
800

40

40

20

20

0
3

P2
2
kW

P2
2
kW

1
0

0
0

1
0 Q m3/h
l/min
0

20

500

40

60
1000

80

1500

100

0
0

m3/h
Q l/min 10
200

20

40

30
400

600

50
800

60
1000
72.2040

72.2039

294

I-GM

AISI 316

Submersible pumps

Characteristic curves
0 U.S. g.p.m. 100
0 Imp. g.p.m.

200

100

300

400

300

200

U.S. g.p.m.

200

0 Imp. g.p.m.100

20

300

400

500

300

200

600

400

500

40
60

I-GMN 30-65

n 2850 1/min

n 2850 1/min

A
15

ft

30

40

H
m

H
m

120

I-GMN 30-80

10

ft

80

20

B
40

20
10

0 Q m3/h
l/min
0

20

60
1000

40

500

80

0
100

1500

40

60
1000

80

1500

100

0
140

120
2000

80

80

60
%
40

60

40

20
0

0
8

P2
3
kW

P2
6
kW

A
B

2
0 Q m3/h
l/min
0

20

60
1000

40

500

20

0 Q m3 /h 20
l/min
0
500

80

100

1500

0 Q m3 /h 20
l/min
0
500

40

60
1000

80

1500

100

120
2000

140

72.2041

U.S. g.p.m.

400

0 Imp. g.p.m. 200

600
400

72.2042

1000

800
600

50

600
400

I-GMN 40-100

240

120

800

n 2850 1/min

70

30

1000

800
600

I-GMN 50-100

n 2850 1/min

ft

60

80

H
m

H
m

400

80

160

40

U.S. g.p.m.

0 Imp. g.p.m. 200

800

20

200

B
C

50

160
ft

40
10

40
120

0 Q m3/h
l/min
0

50
1000

100

2000

150

3000

0
250
4000

200

30

80

50
1000

100

2000

150

3000

200

250
4000

80

60

60

40

40

20

20

20

60

S
B

P2
15
kW

50
1000

100

2000

150

3000

B
C

20

D
0 Q m3/h
l/min
0

P2
40
kW

10
5

0 Q m 3/h
l/min
0

200

250
4000
72.2043

0 Q m 3/h
l/min
0

50
1000

100

2000

150

3000

200

250
4000
72.2044

295

35

I-GM

AISI 316

Submersible pumps

Characteristic curves
0

U.S. g.p.m.

400

0 Imp. g.p.m. 200

600
400

0 U.S. g.p.m.

1000

800
600

400

0 Imp. g.p.m.

800

600

400

800
600

1000
800

1200
1000

1200

25

20

I-GMN4 60-100
B

15

n 1450 1/min

80

I-GMN4 80-100

60

n 1450 1/min

20
ft

60

H
m

40

ft

15

H
m

10

40

10
20
5

20
5

0 Q m3/h
l/min
0

100

50
1000

2000

150

3000

0
250
4000

200

80

4000

300
5000

0
340

60

40
20

12

P2
6
kW

B
0 Q m3/h
l/min
0

100

50
1000

2000

150

3000

U.S. g.p.m.

800

0 Imp. g.p.m. 400

1200
800

200

250
4000

30

1600

I-GMN4 100-150

A
25

n 1450 1/min

80

B
20

60

H
m
15

ft
40

10
20

0 Q m 3/h
l/min
0

100
2000

200

4000

300

6000

0
500
8000

400

80

60

40

20
0
30

P2
20
kW

10
0 Q m 3/h
l/min
0

100
2000

200

4000

300

6000

400

0 Q m /h
l/min 1000
0

100
2000

200
3000

4000

300
5000

340
72.2046

2000

1600
1200

72.2045

P2
8
kW

200
3000

20

100
2000

80

60
%
40

0 Q m 3/h
l/min 1000
0

500
8000
72.2047

296

I-GM

Submersible pumps

AISI 316

Dimensions and weights

I-GMV 50-50

52
12

86

450 min.
312
194

3/4

555

HL

330

50
125

75

28

G 2
118

134

176

55
150

HL minimum submersible level

132
100

13

110
156

90

112 112

137

50

16

136

Version with duck foot coupling

Version with threaded flange and 90 elbow

TIPO
TYPE
TYPE
I-GMV 50-50C/A
I-GMV 50-50B/B
I-GMV 50-50A/B

Peso
Weight
kg
46

297

400 min

392

35

I-GM

AISI 316

Submersible pumps

Dimensions and weights

I-GMV4 50-65
I-GMC 40-65
13
78
83

600 min
447

33

85

317

100

180

117

DN 65
EN 1092-2
PN 10

121

335

60

47

567

253

HL

200
HL minimum submersible level

50

92

130
198
120

180

92

18
720
181

1/

130 130

2
15

96

90

15

Version with threaded flange and 90 elbow

TIPO
TYPE
TYPE
I-GMV4 50-65C/A
I-GMV4 50-65B/A
I-GMV4 50-65A/A
I-GMC 40-65B/A
I-GMC 40-65A/A

Version with duck foot coupling

Peso
Weight
kg
47
49

298

360 min.

141
69

I-GM

AISI 316

Submersible pumps

Dimensions and weights

13

I-GMN 30-65

78
83

625 min.
495

33

85
357

100

180

117

DN 65
EN 1092-2
PN 10

300

253
216

DN 65
EN 1092-2
PN 10

456

HL

90

78
HL minimum submersible level

DN 80
EN 1092-2
PN 10

92

200
92

120

138

198

220

18

767

150

184

140

35

364

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
I-GMN 30-65B/A
I-GMN 30-65A/A

360 min

145

133

60

Peso
Weight
kg
62

299

I-GM

AISI 316

Submersible pumps

Dimensions and weights

I-GMV4 50-80
I-GMN 30-80

13

d1 min.

78
83

d2
33

85

d3

100

180

116

DN 80
EN 1092-2
PN 10

370
256

fM

DN 80
EN 1092-2
PN 10

200

HL

hf
a
HL minimum submersible level

DN 80
EN 1092-2
PN 10

250
100

160

20

160

100

210

h1

210

h2

18
d4
179

131

a2

g2

a1

412 min

80

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
I-GMV4 50-80B/A
I-GMV4 50-80A/A
I-GMN 30-80B/A
I-GMN 30-80A/A
I-GMN 30-80S/A

Dimensions
Dimensioni - Dimensions
mm
mm

DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

80

80

519

363

84

116

136

157

658

511

366

791

145

220

370

140

67

80

80

515

330

110

90

133

145

700

511

366

791

145

220

370

140

83

100

80

767

438

132

68

165

165

700

571

386

851

185

220

476

150

170

EN 1092-2
PN 10

300

I-GM

AISI 316

Submersible pumps

Dimensions and weights

I-GMN 40-100
I-GMN 50-100
I-GMN4 60-100
I-GMN4 80-100

13
78

33

83

d1 min.

100

d2
d3

85

220

190

116

fM
I-GMN
50-100

DN2

HL

I-GMN
40-100

HL minimum submersible level

DN1

I-GMN4
60-100
80-100

400

hf

266

220

DN2

h1

h2

250
100

160
210

20

210
160

100

18
d4
231

131

a1

g2

a2

550 min

100

n3

Version with foot and 90 elbow

TIPO
TYPE
TYPE
I-GMN 40-100D/A
I-GMN 40-100C/A
I-GMN 40-100B/A
I-GMN 40-100S/A
I-GMN 50-100C/A
I-GMN 50-100B/A
I-GMN 50-100A/A
I-GMN4 60-100B/A
I-GMN4 60-100A/A
I-GMN4 80-100B/A
I-GMN4 80-100A/A

35

Version with duck foot coupling

Dimensions
Dimensioni
- Dimensions
mm
mm

DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

125

100

845

478

127

73

168

184

750

628

441

928

187

275

500

150

222

125

100

1269

570

127

73

193

193

800

628

441

928

187

275

500

150

360

125

100

1033

628

62

139

180

231

850

673

466

973

207

300

500

150

390

125

100

852

526

54

147

189

212

800

640

445

940

195

279

500

150

170

125

100

921

570

53

147

189

212

800

640

445

940

195

279

500

150

220

EN 1092-2
PN 10

301

I-GM

AISI 316

Submersible pumps

Dimensions and weights

I-GMN4 100-150

13
78
33

83

d1 min.

100

d2
d3

85

222

116

DN2
fM
DN2

383

538

hf

HL minimum submersible level

DN1
h1

h2

300
100

200

20

200

250

100

250

285

HL

18

d4

l1

g2

l2

740 min

131

n3

Version with duck foot coupling

Version with foot

TIPO
TYPE
TYPE
GMN4 100-150B/A
GMN4 100-150A/A

Dimensions
Dimensioni
- Dimensions
mm
mm

EN 1092-2
PN 10
DN1

DN2

150

150

fM
991
1055

HL
576
600

hf

l1

l2

d1

d2

d3

100

160

235

305

990

931

566 1208

302

d4

h1

h2

n3

g2

280

400

600

225

Peso
Weight
kg
370
405

B-GM

B 10

Submersible pumps

Construction
Submersible pumps, B 10 bronze marine version.
B-GMV with free-flow (vortex) impeller
B-GMC with single-channel impeller
B-GMN with channels impeller
Twin mechanical seal with oil chamber (lip-seal motor side up to
2,4 kW 2 poles).
Delivery connection DN 50-65-80

Applications
Suitable to pump industrial waste water in chemical, and process
industries, agricultural and marine areas.
Solid passage from 30 to 50 mm

Operating conditions
Liquid temperature up to 40 C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).

Motor

Main materials

2 or 4 poles induction, 50Hz


Three-phase version: 400V 10%, up to 3,2 kW
400/690V 10%, over 3,2 kW
Insulation class: H
Protection degree: IP 68
N of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.

Pump casing, Motor casing, Motor cover: B 10 bronze marine


Impeller: stainless steel AISI 316
Motor shaft: stainless steel AISI 316L
Screws: stainless steel AISI 316
Mechanical seal motor side: graphite/ceramic/FPM (lip-seal made of nitrile up to
2,4 kW 2 poles).
Mechanical seal pump side: silicon carbide/silicon carbide/FPM

Coverage chart
30

B-GM
20

H
m

35

B-GMN

B-GMC
10

B-GMV

72.2005

2
2

Q m3/h

10

15

303

20

30

40

50

100 120

B-GM

B 10

Submersible pumps

Technical data
Power Supply

TYPE

B-GMV 50-50C/A
B-GMV 50-50B/B
B-GMV 50-50A/B

P2
kW
1,8
1,6
2,4

IN
A
3,5
3,1
4,5

B-GMV4 50-65C/A
B-GMV4 50-65B/A
B-GMV4 50-65A/A
B-GMV4 50-80B/A
B-GMV4 50-80A/A

1,1
1,4
1,6
2,3
2,8

B-GMC 40-65B/A
B-GMC 40-65A/A
B-GMN 30-65B/A
B-GMN 30-65A/A
B-GMN 30-80B/A
B-GMN 30-80A/A
P2 Rated power output

Starting

3~ 400V
3~ 400V
3~ 400V

1/min
r.p.m.
2850
2850
2850

2,4
2,7
3,1
4,4
3,4

3~ 400V
3~ 400V
3~ 400V
3~ 400V
3~ 400V

2,1
2,8

3,9
5,2

3,1
3,6
5
6,5

5,8
6,6
9,1
11,8

IN Rated current

Free
passage

Thermal
protector

Humidity
probe

D.O.L.
D.O.L.
D.O.L.

DN
mm
50
50
50

50
50
50

NO
NO
NO

NO
NO
NO

1450
1450
1450
1450
1450

D.O.L.
D.O.L.
D.O.L.
D.O.L.
D.O.L.

65
65
65
80
80

50
50
50
50
50

NO
NO
NO
NO
NO

NO
NO
NO
NO
NO

3~ 400V
3~ 400V

2850
2850

D.O.L.
D.O.L.

65
65

40
40

NO
NO

NO
NO

3~ 400V
3~ 400V
3~ 400/690V
3~ 400/690V

2850
2850
2850
2850

D.O.L.
D.O.L.

65
65
80
80

30
30
30
30

NO
NO

NO
NO

Standard

304

ATEX
Eex

ATEX Eex Version on demand

B-GM

B 10

Submersible pumps

Characteristic curves
0

U.S. g.p.m.

Imp. g.p.m.

50

100

150

50

100

10

15

10

U.S. g.p.m.

80

120

40

n 2850 1/min

H
m

30

ft

20

240

160

120

200
30

B-GMV4 50-65
n 1450 1/min

H
m

200

160

80

Imp. g.p.m.

B-GMV 50-50
A

25
ft

20

C
15
ft

10

3
10

2
5
1

0 Q m3/h
0 l/min 100

10

20
200

300

0
40

30
500

400

600

50

50

40

40

20
10

0 Q m3/h
0 l/min 100

10

20
200

300

30
500

400

m3/h
Q l/min 10
200

20

40

30
400

10

A
B

A
B

1,2

P2
0,8
kW
0,4
0

40

0
0

600

0
60
1000

50
800

600

20

2
1,5
P2
1
kW
0,5

0
0

m3/h
Q l/min 10
200

20

40

30
400

50
800

600

60
1000
72.2038

72.2037

0 U.S. g.p.m. 100


0 Imp. g.p.m.

200

100

300

400

300

200

10

20

8
H
m

U.S. g.p.m.
Imp. g.p.m.

80

120
80

160

240

200

120

30

B-GMV4 50-80

160

200
60

B-GMC 40-65

n 1450 1/min

n 2850 1/min

ft

15

20

H
m

50
ft

6
5

40

10

30

ft
20

10

5
2
10
1
0

0 Q m 3/h
l/min
0

20

500

40

60
1000

80

1500

0
100

60

60

m3/h
Q l/min 10
200

20

40

30
400

600

0
60
1000

50
800

40

40

20

20

0
3

P2
2
kW

P2
2
kW

1
0

0
0

1
0 Q m 3/h
l/min
0

20

500

40

60
1000

80

1500

100

0
0

m3/h
Q l/min 10
200

20

40

30
400

600

50
800

60
1000
72.2040

72.2039

305

35

B-GM

B 10

Submersible pumps

Characteristic curves
0 U.S. g.p.m. 100
0 Imp. g.p.m.

200

300
200

100

400

U.S. g.p.m.

200

0 Imp. g.p.m.100

300

20

300
200

400

500

300

400

600
500

30
60

B-GMN 30-65

B-GMN 30-80
n 2850 1/min

n 2850 1/min

80

ft

15

H
m

20

ft

40

H
m

10

40
10

20
5

0 Q m 3/h
l/min
0

20

500

40

60
1000

80

1500

0
100

40

60
1000

80

1500

100

120
2000

0
140

80

80

60
%
40

60

40

20
0

0
6

P2
3
kW

20

P2
4
kW

2
1

0 Q m3 /h 20
l/min
0
500

0 Q m 3/h
l/min
0

20

500

40

60
1000

80

1500

100
72.2041

0 Q m3 /h 20
l/min
0
500

40

60
1000

80

1500

100

120
2000

140
72.2042

306

B-GM

B 10

Submersible pumps

Dimensions and weights

B-GMV 50-50

52
12

86

450 min.
312
194

3/4

544

HL

330

50
125

75

28

G 2
118

134

55
150

176

HL minimum submersible level

132
100

13

110
156

90

112 112

137

50

16

136

Version with duck foot coupling

Version with threaded flange and 90 elbow

TIPO
TYPE
TYPE
B-GMV 50-50C/A
B-GMV 50-50B/B
B-GMV 50-50A/B

Peso
Weight
kg
48

307

400 min

392

35

B-GM

B 10

Submersible pumps

Dimensions and weights

B-GMV4 50-65
B-GMC 40-65
13
78
83

600 min
447

33

85

317

100

180

117

DN 65
EN 1092-2
PN 10

121

335

60

47

556

253

HL

200
HL minimum submersible level

50

92

130
198
120

180

92

18
720
181

2
1/

130 130

2
15

96

90

15

Version with duck foot coupling

Version with threaded flange and 90 elbow

TIPO
TYPE
TYPE
B-GMV4 50-65C/A
B-GMV4 50-65B/A
B-GMV4 50-65A/A
B-GMC 40-65B/A
B-GMC 40-65A/A

Peso
Weight
kg
48
50

308

360 min.

141
69

B-GM

B 10

Submersible pumps

Dimensions and weights

13

B-GMN 30-65

78
83

625 min.
495

33

85
357

100

180

117

DN 65
EN 1092-2
PN 10

300

253
216

DN 65
EN 1092-2
PN 10

456

HL

90

78
HL minimum submersible level

DN 80
EN 1092-2
PN 10

92

200
92

120

138

198

220

18

767
150

184

140

35

364

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
B-GMN 30-65B/A
B-GMN 30-65A/A

360 min

145

133

60

Peso
Weight
kg
65

309

B-GM

B 10

Submersible pumps

Dimensions and weights

13

B-GMV4 50-80
B-GMN 30-80

d1 min.

78
83

d2
33

85

d3

100

180

116

DN 80
EN 1092-2
PN 10

370
256

fM

DN 80
EN 1092-2
PN 10

200

HL

hf
a
HL minimum submersible level

DN 80
EN 1092-2
PN 10

250
20

160

100

160

210

100

210

h1

h2

18
d4
179

131

a2

g2

a1

412 min

80

n3

Version with duck foot coupling

Version with foot and 90 elbow

TIPO
TYPE
TYPE
B-GMV4 50-80B/A
B-GMV4 50-80A/A
B-GMN 30-80B/A
B-GMN 30-80A/A

Dimensions
Dimensioni - Dimensions
mm
mm

DN1

DN2

fM

HL

hf

l1

l2

d1

d2

d3

d4

h1

h2

n3

g2

Peso
Weight
kg

80

80

519

363

84

116

136

157

658

511

366

791

145

220

370

140

73

80

80

515

330

110

90

133

145

700

511

366

791

145

220

370

140

90

EN 1092-2
PN 10

310

GM

Submersible Pumps

Features

Motor shaft made of stainless steel


AISI 420B over dimensioned for
heavy duty
Dry motor for increased safety

Bearings over dimensioned for


heavy duty

Intermediate oil chamber


for a correct lubrication
and cooling.

Twin mechanical seal

35

Impellers and volutes are developed to optimize the


hydraulic efficiency and provide a clear exit for filamentous
and solid materials.

311

GM

Submersible Pumps

THE IMPELLERS

THE STANDARD INSTALLATIONS


Vortex impeller suitable for pumping
liquids containing large solids and/or
fibrous materials.
Applications: urban sewerage systems,
animal breeding plants.

A Mobile and emergency installation


with x-foot support

Sand Vortex Water Impeller in


Polyurethane with a stainless steel core.
Applications: in plants with an high
sand presence, in marble work companies, in the ceramic industry, crystals
machining or industrial processes where
there's presence of abrasives liquids.

B Free installation and threated elbow

GMV

GMVS

Single channel impeller, for liquids


containing fibrous materials and/or
suspended solids.
Applications: purification plants, tanneries, animal breeding plants.

C Fixed installation with automatic


coupling feet and guide rails.

GMC
Closed multi-channel impeller, for clean
liquids or light solids without filamentous
materials.
Applications: large drainage systems,
purification plants.

D Dry pit installation, with x-foot rest


and suction bend.
Pump equipped with cooling jacket.

GMN

GMG

Multi-blade suction impeller with grinder


constructed in stainless steel AISI 440,
particularly suitable as a grinder for paper
or textile materials.
Applications: clearance of waste waters
originating from service stations, residential
communities, camping sites, etc..

312

GM

Submersible pumps

Installation with duck foot coupling

Allarme
Alarm

1 Submersible pump

2 Duck foot coupling

3 Guide pipes

Marcia 2
Activation 2

Marcia 1
Activation 1

4 Delivery pipe
5 Check valve
6 Gate valve

Arresto
Stop

7 Level floats
8 Control box

35

313

GM

Submersible pumps

Accessories
Non-return ball valves
Construction
Non-return self-cleaning ball valves, suitable for dirty and viscous liquids, sewage water.

Operating conditions
Working temperature from -10C up to +80C
Rated pressure: 10 bar
Vertical or horizontal installation

Materials
Valve body: Cast iron EN-GJL-250
Cover:
Cast iron EN-GJL-250
Ball:
Resin for threaded VNRP
Resin + nitril for VNRP DN 50-100
Cast iron + nitril for VNRP DN 125-250
Screws: SS AISI 304
Joint: nitril

Dimensions
B
DN

DN

Dimensioni - Dimensions

Dimensioni - Dimensions
mm

DN
mm

Peso
Weight
kg

VNRP 1 1/4

1 1/4

132

111

83

108

1,9

VNRP 1 1/2

1 1/2

145

122

90

120

2,4

173

145

110

135

2 1/2

200

175

130

155

TYPE
TIPO
TYPE

VNRP 2
VNRP 2 1/2

mm
DN
mm

Peso
Weight
kg

VNRP 50

50

182

192

120

165

9,5

VNRP 65

65

204

215

124

185

14

3,6

VNRP 80

80

260

250

150

200

19,5

6,5

VNRP 100

100

300

290

180

220

23,5

VNRP 125

125

350

340

215

250

36

VNRP 150

150

400

388

245

285

38,5

VNRP 200

200

500

480

310

340

69

TYPE
TIPO
TYPE

314

09/2016

GEOTRIT

Macerating pumping system


Construction
This macerating pumping system has been designed to pump
away the waste water from a WC and a washbasin.
It is possibile to use it to add a new cloakroom, washroom or
toilet, in a basement or loft conversion or anywhere
conventional large bore pipework is impractical.
The GEOTRIT macerating system is installed in a case
specifically designed for horizontal outlet spigots.
Installed and used correctly, this unit will give consistent and
reliable service.
The system has a grinder pump, clapet valve and carbon filter.
GEOTRIT is provided with flexible sleeves, elbow, metal hose
clips.

Operating conditions
Voltage: 220-240 V
Frequency: 50 Hz
Degree of protection: IP44
Maximum power rating: 400 W
Maximum current consumption: 1,9 A
Vertical pumping: max. 4 m
Liquid temperature up to 35 C

Application
GEOTRIT takes waste from :

WC

Washbasin

Characteristic curve
0

U.S. g.p.m. 5

Imp. g.p.m.

10
5

15

20

10

25

15

20

10

32

GEOTRIT

36

28

24

ft

16

12
8

4
0

0
0
0

m 3/h
l/min

2
20

30

40

3
50

4
60

5
70

80

6
100

90

72.1222

315

m3/h
l/min

Hm

1,2

2,4

3,6

4,8

5,4

20

40

60

80

90

7,1

5,9

4,3

2,2

1,1

GEOTRIT

Macerating pumping system

Installation

4.93.486

Performance

1%

4 m max

max 10 m
max 20 m

3m

28/32/40

max 40 m

1m

22/28/32 mm

max 30 m

2m

3%

DN 40

mm

4.93.481

Dimensions and weights


52

184,7

318,5

55,5

183

258

344

317

271,5

peso: kg 6,6

4.93.483

427

235

316

mm
1%

GEOCOMP

Macerating pumping system


Construction
This macerating pumping system has been designed to pump
away the waste water from WC, washbasin, bidet and shower.
It is possible to install a complete bathroom in a basement
conversion or loft extension.
The GEOCOMP macerating system is installed in a case
specifically designed for horizontal outlet spigots.
Installed and used correctly, this unit will give consistent and
reliable service.
The system has a grinder pump, clapet valve and carbon filter.
GEOCOMP is provided with flexible sleeves, elbow, metal hose
clips.

Operating conditions
Voltage: 220-240 V
Frequency: 50 Hz
Degree of protection: IP44
Maximum power rating: 400 W
Maximum current consumption: 1,9 A
Vertical pumping: max. 4 m
Liquid temperature up to 35 C

Application
GEOCOMP takes waste from :

WC

Washbasin

Bidet

Tube

Shower

Characteristic curve
0

U.S. g.p.m. 5

Imp. g.p.m.

10
5

15

20

10

25

15

20

10

32

GEOCOMP

36

28

24

ft

16

12
8

4
0

0
0
0

m 3/h
l/min

2
20

30

40

3
50

4
60

5
70

80

6
100

90

72.1222

317

m3/h
l/min

Hm

1,2

2,4

3,6

4,8

5,4

20

40

60

80

90

7,1

5,9

4,3

2,2

1,1

GEOCOMP

Macerating pumping system

Installation

4.93.485

Performance

1%

max 10 m

4 m max

max 20 m

3m

max 30 m

2m

max 40 m

1m

4.93.481

Dimensions and weight


52

55,5

41,5

166

184,7

318,5
183

258

344

317

271,5

weight:
kg 6,6
6,8
peso: kg

4.93.482

427,5

235

318

GEOCLEAN

Lifting station for clear water


Construction
The system is design to handle the evacuation water from a
domestic kitchen sink, dishwasher and washing machine all
working at the same time if required.
GEOCLEAN makes the addition of a domestic kitchen or utility
room easy even when below or distant from a drain.
The system has a clapet valve and it cannot be used with waste
waters.
GEOCLEAN is provided with flexible sleeves, elbow, metal hose
clips, plugs.

Operating conditions
Voltage: 220-240 V
Frequency: 50 Hz
Degree of protection: IP44
Maximum power rating: 400 W
Maximum current consuption: 1,9 A
Vertical pumping: max. 5 m
Liquid temperature up to 60 C

Application
GEOCLEAN takes waste from :

Washbasin

Bidet

Tube

Shower

Kitchen sink

Dishwasher

Washing machine

Characteristic curve
0

U.S. g.p.m. 5

Imp. g.p.m.

10
5

15

20

10

25

15

20

10

32

GEOCLEAN

36

28

24

ft

16

12
8

4
0

0
0
0

m 3/h
l/min

2
20

30

40

3
50

4
60

5
70

80

6
100

90

72.1222

319

m3/h
l/min

Hm

1,2

2,4

3,6

4,8

5,6

20

40

60

80

93

7,1

5,9

4,5

2,7

GEOCLEAN

Lifting station for clear water


Performance

Installation

1%

5 m max
4m
3m

max 5 m
max 10 m
max 20 m
max 30 m

2m

max 40 m

1m

4.93.484

4.93.479

4.93.484

Dimensions and weight


52

55,5

318,5
41,5

258

344

317

271,5

4.93.480

weight:
kg 6,4
6,4
peso: kg
427,5

112

320

09/2016

GEO

Automatic waste water collecting


and lifting station
Construction
Medium-density polyethylene tank, resistant to corrosion,
with minimum overall dimensions.

GEO 40

- GEO 40 single tank with 40 liters nominal capacity for the


installation of a GXRM type.
- GEO 230 single tank with 230 liters nominal capacity for the
installation of an electropump type GM 10, GQ, GX or GM
series.

GEO 230
- GEO 500 double tank with 500 liters nominal capacity for the
installation of two electropumps type GM 10, GQ, GX or GM
series.
Pipe kit for electropump connection.
Two possible installation, at ground level or underground.
For underground installation, extentions can be used (maximum
two extentions).
Easy pump access through a cover fixed with screws.

Applications
Automatic waste water collecting and lifting stations, to handle
domestic, civil and industrial waste water.
For collecting and lifting clean waste water and rain water.
For flood drainage.

Designation
GEO 40-GXRM 9
GEO 500

Series
Nominal tank capacity
Pump type

GEO 230-GXVM 40-7


Series
Nominal tank capacity
Pump type

GEO 500-2 GXVM 40-7


Series
Nominal tank capacity
Nr of pumps
Pump type

37
Installation examples
GEO 40-GXR

GEO 230-GX..

321

GEO 500-2GM..

GEO 40

Automatic clear water collecting


and lifting station

Pumps characteristics
GEO 40-GXRM

GEO 40-GXRM GF

Features
Automatic collecting and lifting station for clean water with GXRM pump
type .

It includes:
1 tank capacity 40 l
1 single-phase pump with 5 m cable and float switch
1 non-return valve with clapet on the pump delivery side
1 discharge pipe kit arranged for the connection of a 40 mm PVC pipe
1 PVC adapting nipple for 40 mm inlet
1 connector for 25 mm flexible pipe

On demand
1 pump with 10 m cable

Single-phase type

Q max
m3/h
10,2
10,2
12
13,2

H max
m
8,3
8,3
10,4
11,7
412

GEO 40-GXRM 9
GEO 40-GXRM 9 GF
GEO 40-GXRM 11 GF
GEO 40-GXRM 13 GF

1 ~ 230 V
kW
A
0,25
2,5
0,25
2,5
0,37
3,5
0,45
4,5

390

350

GXRM

GXRM GF

Submersible drainage pump in chrome-nickel stainless steel, for clean water containing
solids up to 10 mm grain size, with vertical delivery port.
Open impeller.
2-pole induction motor, 50Hz (n 2900 rpm),
Single-phase 230 V +/-10% with float switch and thermal protector.
- GXRM: with standard float switch.
- GXRM .. GF: with vertical magnetic float switch.
Incorporated capacitor.
Cable length 5 m, Shuko plug.
Liquid temperature up to 35 C

GXRM
14

GXRM
12
GX

RM

10

GX

RM

13
11

GX

RM

0
0

m3/h
l/min 50

10
100

150

322

15
200

250

GEO 230

Automatic clear water collecting


and lifting station

Pumps characteristics
GEO 230-GM 10

Features
Automatic clear water collecting and lifting station GM 10 pump series.

It includes:

1 tank capacity 230 l


1 single-phase pump with 5 m cable and float switch
1 control box QM 6,3 type with capacitor
1 discharge pipe kit 40 mm in PVC

On demand
1 pump with 10 m cable
1 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball
valve
1 support kit with safety float switch and auto-supplied control panel for
remote alarm with horn and flashing light
- extention 300 mm

GEO 230-GM 10

1 ~ 230 V
kW
A
0,3
1,75

Q max
m3/h
12

H max
m
6,5
710

Single-phase type

60

800

GM 10
Submersible drainage pump constructed from composite polymers.
Shaft of chrome steel AISI 430.
2-pole induction motor, 50Hz (n 2900 rpm).
Single-phase 230 V +/-10% with thermal protector.
Float switch for automatic operation.
5 m cable and control box QM 6,3 with capacitor.
Liquid temperature up to 35 C

0 Imp. g.p.m.10

30

20

40

8
H
m

ft

20
GM 10

4
10
2

0
0

m3/h
l/min

3
50

6
100

323

9
150

0
12
200

37

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GX..

Features
Automatic collecting and lifting station - for clean water GXR pump series.
- for waste water GXV pump series.

It includes:

1 tank capacity 230 l


1 single-phase pump with 5 m cable and float switch
1 discharge pipe kit 40 mm in PVC

On demand
1 pump with 10 m cable
1 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball valve
1 support kit with safety float switch and auto-supplied control panel for remote
alarm with horn and flashing light
- extention 300 mm

GEO 230-GXVM 25-6


GEO 230-GXVM 25-8
GEO 230-GXVM 25-10
GEO 230-GXRM 9
GEO 230-GXRM 11
GEO 230-GXRM 13

Q max
m3/h
10,2
12
13,2
10,2
12
13,2

H max
m
5,7
7,8
9,5
8,3
10,4
11,7

710

1 ~ 230 V
kW
A
0,25
2,5
0,37
3,5
0,45
4,5
0,25
2,5
0,37
3,5
0,45
4,5

Single-phase type

60

800

GXRM, GXVM
Submersible drainage pump in chrome-nickel stainless steel, with vertical delivery port.
GXRM: with open impeller.
GXVM: with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n 2900 rpm),
Single-phase 230 V +/-10% with float switch and thermal protector. Incorporated capacitor.
Cable length 5 m.
Liquid temperature up to 35 C

GXVM

GXRM

14

14

GXRM

GXVM

12

12
GX

RM

10

GX

RM

13

10
GX

VM

11

GX

RM

10

VM

25-

25-

GX

6
GX

VM

25-

0
0

m3/h
l/min 50

10
100

150

15
200

250

324

0
0

m3/h
l/min 50

10
100

150

15
200

250

GEO 230

Automatic clear water collecting


and lifting station

Pumps characteristics
GEO 230-GQR..

Features
Automatic collecting and lifting station for clean water with GQR pump series.

It includes:

1 tank capacity 230 l


1 pump - single-phase with 10 m cable and float switch
- three-phase with 10 m cable with support and float switch kit
1 control box for three-phase version
1 discharge pipe kit 50 mm in PVC

On demand

Single-phase type
GEO 230-GQRM 10-10
GEO 230-GQRM 10-12
GEO 230-GQRM 10-14
GEO 230-GQRM 10-16
GEO 230-GQRM 10-18
GEO 230-GQRM 10-20
Three-phase type
GEO 230-GQR 10-10
GEO 230-GQR 10-12
GEO 230-GQR 10-14
GEO 230-GQR 10-16
GEO 230-GQR 10-18
GEO 230-GQR 10-20

1 ~ 230 V
kW
A
0,45
3,1
0,55
3,6
0,75
4,6
0,9
6
1,1
8
1,5
12

Q max
m3/h
18
21
24
27
30
30

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

3 ~ 400 V
kW
A
0,45
1,2
0,55
1,4
0,75
1,6
0,9
2,3
1,1
2,8
1,5
3,8

Q max
m3/h
18
21
24
27
30
30

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

710

1 discharge pipe kit 50 mm in PVC with a ball valve and non-return ball valve
1 support kit with safety float switch and auto-supplied control panel for remote
alarm with horn and flashing light
- extention 300 mm

60

800

GQR
Single-impeller submersible drainage pump, with vertical delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n 2900 rpm),
GQR:
three-phase 400 V +/-10%;
GQRM: Single-phase 230 V +/-10% with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 C
0

U.S. g.p.m.

20

40

60

80

100

120

140

22
70
20

GQR 1
0 (32)20
GQR 1
0 (32)18
GQR 1
0 (32)16

18

H
m
14
12
10
8

60

50
ft

GQR 1
0 (32)14
GQR 1
0 (32)12

40

GQR 1
0 (32)10

30

20

6
4

10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

325

30
400

500

37

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GQR..

Features
Automatic collecting and lifting station for clean water with GQR pump series.

It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 duck foot coupling kit
1 discharge pipe kit 63 mm in PVC with a ball valve and non-return ball
valve

On demand

Single-phase type
GEO 230-GQRM 10 32-10
GEO 230-GQRM 10 32-12
GEO 230-GQRM 10 32-14
GEO 230-GQRM 10 32-16
GEO 230-GQRM 10 32-18
GEO 230-GQRM 10 32-20
Three-phase type
GEO 230-GQR 10 32-10
GEO 230-GQR 10 32-12
GEO 230-GQR 10 32-14
GEO 230-GQR 10 32-16
GEO 230-GQR 10 32-18
GEO 230-GQR 10 32-20

1 ~ 230 V
kW
A
0,45
3,1
0,55
3,6
0,75
4,6
0,9
6
1,1
8
1,5
12

Q max
m3/h
18
21
24
27
30
30

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

3 ~ 400 V
kW
A
0,45
1,2
0,55
1,4
0,75
1,6
0,9
2,3
1,1
2,8
1,5
3,8

Q max
m3/h
18
21
24
27
30
30

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

710

1 safety float switch (with support for single-phase version) and autosupplied control panel for remote alarm with horn and flashing light
- extention 300 mm

60

800

GQR
Single-impeller submersible drainage pump, with horizontal delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n 2900 rpm),
GQR:
three-phase 400 V +/-10%;
GQRM: Single-phase 230 V +/-10% with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 C

U.S. g.p.m.

20

40

60

80

100

120

140

22
70
20

GQR 1
0 (32)20
GQR 1
0 (32)18
GQR 1
0 (32)16

18

H
m
14
12
10
8

60

50
ft

GQR 1
0 (32)14
GQR 1
0 (32)12

40

GQR 1
0 (32)10

30

20

6
4

10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

326

30
400

500

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GX..

Features
Automatic waste water collecting and lifting station GX 40 pump series.

It includes:
1 tank capacity 230 l
1 pump - single-phase with 10 m cable and float switch
- three-phase with 10 m cable with support and float switch kit
1 control box for three-phase version
1 discharge pipe kit 50 mm in PVC

On demand

Single-phase type
GEO 230-GXCM 40-10
GEO 230-GXCM 40-13
GEO 230-GXVM 40-7
GEO 230-GXVM 40-8
GEO 230-GXVM 40-9
Three-phase type
GEO 230-GXC 40-10
GEO 230-GXC 40-13
GEO 230-GXV 40-7
GEO 230-GXV 40-8
GEO 230-GXV 40-9

1 ~ 230 V
kW
A
0,55
4,6
0,9
6,6
0,55
4,6
0,75
5,4
0,9
6

Q max
m3/h
21
26
15
18
21

H max
m
9
11,6
6,2
7,2
8,1

3 ~ 400 V
kW
A
0,55
1,6
0,9
2,3
0,55
1,6
0,75
2,2
0,9
2,3

Q max
m3/h
21
26
15
18
21

H max
m
9
11,6
6,2
7,2
8,1

710

1 discharge pipe kit 50 mm in PVC with a ball valve and non-return ball
valve
1 safety float switch (with support for single-phase version) and autosupplied control panel for remote alarm with horn and flashing light
- extention 300 mm

60

800

GXC, GXV
Submersible sewage and drainage pumps in chrome-nickel stainless steel, with vertical delivery port.
GXC, with two-passage impeller.
GXV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n 2900 rpm).
GXC, GXV:
three-phase 400 V; +/-10%
GXCM, GXVM: single-phase 230 V +/-10%, with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 C

U.S. g.p.m.

40

60

80

100

U.S. g.p.m.

120

30

40

50

60

70

80

90

37

100

10

14

30
40

12

m
10

ft

GX
8

GX

C4

0-1

30

C4

0-1

ft

H
m

GX GXV
4
V4
0-8 0-9
V4
0-7

20

GX

20
4
10

4
10

0
0

m 3/h

12

18

24

30

l/min

100

200

300

400

500

0
0

m 3/h

12

18

l/min

100

200

300

24
400
72.918-N

327

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GQG

Features
Automatic sewage water collecting and lifting station with grinder pumps
GQG series.

It includes:
1 tank capacity 230 l
1 pump - single-phase with 10 m cable without float switch
- three-phase with 10 m cable
1 support kit with float switch
1 control box (with capacitor for single-phase motors)
1 duck foot coupling kit
1 discharge pipe kit 63 mm in PVC with a ball valve and non-return ball
valve

On demand

1 ~ 230 V
kW
A
0,9
7
1,1
7,5
1,5
9,5

Q max
m3/h
13,2
15
16,8

H max
m
16,5
19,2
23

Three-phase type

3 ~ 400 V
kW
A

Q max
m3/h

GEO 230-GQG 6-18


GEO 230-GQG 6-21
GEO 230-GQG 6-25

0,9
1,1
1,5

H max
m
16,5
19,2
23

Single-phase type
GEO 230-GQGM 6-18
GEO 230-GQGM 6-21
GEO 230-GQGM 6-25

2,3
2,8
3,8

13,2
15
16,8

710

1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm

60

800

GQG
Submersible pumps with high power grinder, with horizontal delivery port.
2-pole induction motor, 50Hz (n 2900 rpm)
GQG:
three-phase 400 V +/-10%;
GQGM: Single-phase 230 V +/-10% complete control box with thermal protector and
capacitors (without float switch).
10 m cable.
Liquid temperature up to 35 C.

0 U.S. g.p.m. 10

20

30

40

50

60

70

30
90

GQG
80

6-25

70
20

6-21

6-18

60
m

50
ft
40

10
30
20
10
0
0
0

m3/h

Q l/min

5
50

10
100

150

328

200

15

18

250

300

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GQS

Features
Automatic waste water collecting and lifting station GQS series.

It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 discharge pipe kit 63 mm in PVC with a ball valve and non-return ball
valve

On demand

Single-phase type
GEO 230-GQSM 50-8
GEO 230-GQSM 50-9
GEO 230-GQSM 50-11
GEO 230-GQSM 50-13
GEO 230-GQSM 50-15
Three-phase type
GEO 230-GQS 50-8
GEO 230-GQS 50-9
GEO 230-GQS 50-11
GEO 230-GQS 50-13
GEO 230-GQS 50-15

1 ~ 230 V
kW
A
0,55
4,3
0,75
4,8
0,9
6,6
1,1
8,4
1,5
12

Q max
m3/h
24
27
33
36
36

H max
m
7,4
8,8
10,5
12,5
14,4

3 ~ 400 V
kW
A
0,55
1,5
0,75
1,8
0,9
2,3
1,1
3
1,5
4

Q max
m3/h
24
27
33
36
36

H max
m
7,4
8,8
10,5
12,5
14,4

710

1 safety float switch (with support for single-phase version) and autosupplied control panel for remote alarm with horn and flashing light
- extention 300 mm

60

800

GQS
Single-impeller submersible pumps, with vertical delivery port.
GQS: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n 2900 rpm)
GQS: three-phase 400 V +/-10%;
GQSM: single-phase 230 V +/-10%, with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 C

0 U.S. g.p.m. 20

40

60

80

100

120

140

18

37

H
50

m
14

GQS,

12

GQS
, GQV

10

GQS,
GQV

GQS
, GQV

GQS
, GQ
V 50
-8

ft

GQV 5

0-15

40

50-13
50-11

30

50-9
20

4
10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

329

400

30
500

0
36
600

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GQV

Features
Automatic waste water collecting and lifting station GQV series.

It includes:
1 tank capacity 230 l
1 pump - single-phase with 10 m cable, without float switch
- three-phase with 10 cable, without float switch
1 support kit with float switch
1 control box
1 duck foot coupling kit
1 discharge pipe kit 63 mm in PVC/inox with a ball valve and non-return
ball valve

On demand

Single-phase type

1 ~ 230 V
kW
A

GEO 230-GQVM 50-8


GEO 230-GQVM 50-9
GEO 230-GQVM 50-11
GEO 230-GQVM 50-13
GEO 230-GQVM 50-15

0,55
0,75
0,9
1,1
1,5

Three-phase type

3 ~ 400 V
kW
A
0,55
1,5
0,75
1,8
0,9
2,3
1,1
3
1,5
4

GEO 230-GQV 50-8


GEO 230-GQV 50-9
GEO 230-GQV 50-11
GEO 230-GQV 50-13
GEO 230-GQV 50-15

Q max
m3/h
24
27
33
36
36

H max
m
7,4
8,8
10,5
12,5
14,4

Q max
m3/h
24
27
33
36
36

H max
m
7,4
8,8
10,5
12,5
14,4

4,3
4,8
6,6
8,4
12

710

1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm

60

800

GQV
Single-impeller submersible pumps, with horizontal delivery port.
GQV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n 2900 rpm)
GQV: three-phase 400 V +/-10%;
GQVM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float switch).
Cable length 10 m.
Liquid temperature up to 35 C

0 U.S. g.p.m. 20

40

60

80

100

120

140

18

H
50

m
14

GQS,

12

GQS
, GQV

10

GQS,
GQV

GQS
, GQV

GQS
, GQ
V 50
-8

ft

GQV 5

0-15

40

50-13
50-11

30

50-9
20

4
10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

330

400

30
500

0
36
600

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GM..

Features
Automatic waste water collecting and lifting station GMV, GMC series.

It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 discharge pipe kit 63 mm in PVC with a ball valve and non-return ball
valve

On demand
1 safety float switch (with support for single-phase version) and autosupplied control panel for remote alarm with horn and flashing light
- extention 300 mm

Single-phase type

Q max
m3/h
36
42
31
35

H max
m
9,5
12,5
8
9,5

3 ~ 400 V
kW
A
0,75
1,9
1,1
2,7
1,5
3,8
0,75
1,9
1,1
2,7
1,5
3,8

Q max
m3/h
36
42
48
31
35
39

H max
m
9,5
12,5
14,5
8
9,5
11,5

710

GEO 230-GMCM 50CE


GEO 230-GMCM 50BE
GEO 230-GMVM 50CE
GEO 230-GMVM 50BE

1 ~ 230 V
kW
A
0,75
4,5
1,1
6,5
0,75
4,5
1,1
6,5

Three-phase type
GEO 230-GMC 50CE
GEO 230-GMC 50BE
GEO 230-GMC 50AE
GEO 230-GMV 50CE
GEO 230-GMV 50BE
GEO 230-GMV 50AE

60

800

GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n 2900 rpm)
GMV, GMC:
three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V 10%, built-in thermal protector and built-in capacitor.
Float switch for automatic operation.
Cable length 10 m.
Liquid temperature up to 35 C.
0

U.S. g.p.m. 50

100

150

200

20

U.S. g.p.m.

50

100

150

13

60

m
16

GMC

40

10

ft

ft

GMV

30

A
40

12

A
B
6

B
C

20

20

8
4

10

4
2

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

42
700

0
48
800

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

0
42
700
72.868.C

331

37

GEO 230

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 230-GM..

Features
Automatic waste water collecting and lifting station GMV, GMC series.

It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 duck foot coupling kit
1 discharge pipe kit 63 mm in PVC with a ball valve and non-return ball
valve

On demand
1 safety float switch (with support for single-phase version) and autosupplied control panel for remote alarm with horn and flashing light
- extention 300 mm
Single-phase type

Q max
m3/h
36
42
31
35

H max
m
9,5
12,5
8
9,5

3 ~ 400 V
kW
A
0,75
1,9
1,1
2,7
1,5
3,8
0,75
1,9
1,1
2,7
1,5
3,8

Q max
m3/h
36
42
48
31
35
39

H max
m
9,5
12,5
14,5
8
9,5
11,5

710

GEO 230-GMCM 50-65C


GEO 230-GMCM 50-65B
GEO 230-GMVM 50-65C
GEO 230-GMVM 50-65B

1 ~ 230 V
kW
A
0,75
4,5
1,1
6,5
0,75
4,5
1,1
6,5

Three-phase type
GEO 230-GMC 50-65C
GEO 230-GMC 50-65B
GEO 230-GMC 50-65A
GEO 230-GMV 50-65C
GEO 230-GMV 50-65B
GEO 230-GMV 50-65A

60

800

GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n 2900 rpm)
GMV, GMC:
three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V 10%, built-in thermal protector and built-in capacitor.
Float switch for automatic operation.
Cable length 10 m.
Liquid temperature up to 35 C.
0

U.S. g.p.m. 50

100

150

200

20

U.S. g.p.m.

50

100

150

13

60

m
16

GMC

40

10

ft

ft

GMV

30

A
40

12

A
B
6

B
C

20

20

8
4

10

4
2

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

42
700

0
48
800

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

0
42
700
72.868.C

332

GEO 500

Automatic clear water collecting


and lifting station

Pumps characteristics
GEO 500-GM 10

Features

Automatic clear water collecting and lifting station with GM 10 pump series.

It includes:

1 tank capacity 500 l


2 single-phase pump with 5 m cable without float switch
1 support kit with 2 float switch
1 control box
2 discharge pipe kit 40 mm in PVC

On demand
2 single-phase pumps with 10 m cable, without float switch
2 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm

GEO 500-2GM 10

1 ~ 230 V
kW
A
0,3x2
1,75x2

Q max
m3/h
12x2

H max
m
6,5

710

Single-phase type

12

00

800

GM 10
Submersible drainage pump constructed from composite polymers.
Shaft of chrome steel AISI 430.
2-pole induction motor, 50Hz (n 2900 rpm).
Single-phase 230 V +/-10% with thermal protector (without float switch).
5 m cable and control box with capacitor.
Liquid temperature up to 35 C

37

H
m
6

GM 10
4

0
0

m /h

12

l/min

50

100

150

200

333

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GX..

Features
Automatic collecting and lifting station - for clean water with GXR pump series
- for waste water with GXV pump series.

It includes:
1 tank capacity 500 l
2 single-phase pump with 5 m cable without float switch
1 support kit with 2 float switch
1 control box
2 discharge pipe kit 40 mm in PVC

On demand

GEO 500-2GXVM 25-6


GEO 500-2GXVM 25-8
GEO 500-2GXVM 25-10
GEO 500-2GXRM 9
GEO 500-2GXRM 11
GEO 500-2GXRM 13

1 ~ 230 V
kW
A
0,25x2
2,5x2
0,37x2
3,5x2
0,45x2
4,5x2
0,25x2
2,5x2
0,37x2
3,5x2
0,45x2
4,5x2

Q max
m3/h
10,2x2
12x2
13,2x2
10,2x2
12x2
13,2x2

H max
m
5,7
7,8
9,5
8,3
10,4
11,7

710

Single-phase type

2 single-phase pumps with 10 m cable, without float switch


2 discharge pipe kit 40 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm

12

00

800

GXRM, GXVM
Submersible drainage pump in chrome-nickel stainless steel, with vertical delivery port.
GXRM: with open impeller.
GXVM: with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n 2900 rpm),
Single-phase 230 V +/-10% with thermal protector. Incorporated capacitor.
Cable length 5 m.
Liquid temperature up to 35 C

GXVM

GXRM
14

14

GXRM

GXVM

12

12
GX

RM

10

GX

RM

13

10
GX

VM

11

GX

RM

10

VM

25-

25-

GX

6
GX

VM

25-

0
0

m3/h
l/min 50

10
100

150

15
200

250

334

0
0

m3/h
l/min 50

10
100

150

15
200

250

GEO 500

Automatic clear water collecting


and lifting station

Pumps characteristics
GEO 500-2GQR

Features
Automatic collecting and lifting station for clean water with GQR pump series

It includes:
1 tank capacity 500 l
2 pumps - single-phase with 10 m cable without float switch
- three-phase with 10 m cable
1 support kit with 2 float switch
1 control box
2 discharge pipe kit 50 mm in PVC

On demand

Single-phase type
GEO 500-2GQRM 10-10
GEO 500-2GQRM 10-12
GEO 500-2GQRM 10-14
GEO 500-2GQRM 10-16
GEO 500-2GQRM 10-18
GEO 500-2GQRM 10-20
Three-phase type
GEO 500-2GQR 10-10
GEO 500-2GQR 10-12
GEO 500-2GQR 10-14
GEO 500-2GQR 10-16
GEO 500-2GQR 10-18
GEO 500-2GQR 10-20

1 ~ 230 V
kW
A
0,45x2
3,1x2
0,55x2
3,6x2
0,75x2
4,6x2
0,9x2
6x2
1,1x2
8x2
1,5x2
12 x2

Q max
m3/h
18x2
21x2
24x2
27x2
30x2
30x2

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

3 ~ 400 V
kW
A
0,45x2
1,2x2
0,55x2
1,4x2
0,75x2
1,6x2
0,9x2
2,3x2
1,1x2
2,8x2
1,5x2
3,8x2

Q max
m3/h
18x2
21x2
24x2
27x2
30x2
30x2

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

710

2 discharge pipe kit 50 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm

12

00

800

GQR
Single-impeller submersible drainage pump, with vertical delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n 2900 rpm),
GQR:
three-phase 400 V +/-10%;
GQRM: Single-phase 230 V +/-10% with thermal protector and incorporated capacitor (without
float switch).
Cable length 10 m.
Liquid temperature up to 35 C.

U.S. g.p.m.

20

40

60

80

100

120

140

22
70
20

GQR 1
0 (32)20
GQR 1
0 (32)18
GQR 1
0 (32)16

18

H
m
14
12
10
8

60

50
ft

GQR 1
0 (32)14
GQR 1
0 (32)12

40

GQR 1
0 (32)10

30

20

6
4

10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

335

30
400

500

37

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GQR

Features
Automatic waste water collecting and lifting station with GQR pump series.

It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box
2 duck foot coupling kit
2 discharge pipe kit 63 mm in PVC with a ball valve and non-return ball
valve

On demand

Single-phase type
GEO 500-2GQRM 32 10-10
GEO 500-2GQRM 32 10-12
GEO 500-2GQRM 32 10-14
GEO 500-2GQRM 32 10-16
GEO 500-2GQRM 32 10-18
GEO 500-2GQRM 32 10-20
Three-phase type
GEO 500-2GQR 32 10-10
GEO 500-2GQR 32 10-12
GEO 500-2GQR 32 10-14
GEO 500-2GQR 32 10-16
GEO 500-2GQR 32 10-18
GEO 500-2GQR 32 10-20

1 ~ 230 V
kW
A
0,45x2
3,1x2
0,55x2
3,6x2
0,75x2
4,6x2
0,9x2
6x2
1,1x2
8x2
1,5x2
12x2

Q max
m3/h
18x2
21x2
24x2
27x2
30x2
30x2

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

3 ~ 400 V
kW
A
0,45x2
1,2x2
0,55x2
1,4x2
0,75x2
1,6x2
0,9x2
2,3x2
1,1x2
2,8x2
1,5x2
3,8x2

Q max
m3/h
18x2
21x2
24x2
27x2
30x2
30x2

H max
m
9,5
11,6
13,5
15,5
17,5
19,5

710

1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm

12

00

800

GQR
Single-impeller submersible drainage pump, with horizontal delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n 2900 rpm),
GQR:
three-phase 400 V +/-10%;
GQRM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float
switch).
10 m cable.
Liquid temperature up to 35 C

U.S. g.p.m.

20

40

60

80

100

120

140

22
70
20

GQR 1
0 (32)20
GQR 1
0 (32)18
GQR 1
0 (32)16

18

H
m
14
12
10
8

60

50
ft

GQR 1
0 (32)14
GQR 1
0 (32)12

40

GQR 1
0 (32)10

30

20

6
4

10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

336

30
400

500

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GX..

Features
Automatic waste water collecting and lifting station with GX 40 pump
series.

It includes:
1 tank capacity 500 l
2 pumps - single-phase with 10 m cable without float switch
- three-phase with 10 m cable
1 support kit with 2 float switch
1 electric control box
2 discharge pipe kit 50 mm in PVC

On demand
2 discharge pipe kit 50 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm
Single-phase type

Q max
m3/h
21x2
26x2
15x2
18x2
21x2

H max
m
9
11,6
6,2
7,2
8,1

3 ~ 400 V
kW
A
0,55x2
1,6x2
0,9x2
2,3x2
0,55x2
1,6x2
0,75x2
2,2x2
0,9x2
2,3x2

Q max
m3/h
21x2
26x2
15x2
18x2
21x2

H max
m
9
11,6
6,2
7,2
8,1

710

GEO 500-2GXCM 40-10


GEO 500-2GXCM 40-13
GEO 500-2GXVM 40-7
GEO 500-2GXVM 40-8
GEO 500-2GXVM 40-8

1 ~ 230 V
kW
A
0,55x2
4,6x2
0,9x2
6,6x2
0,55x2
4,6x2
0,75x2
5,4x2
0,9x2
6x2

Three-phase type
GEO 500-2GXC 40-10
GEO 500-2GXC 40-13
GEO 500-2GXV 40-7
GEO 500-2GXV 40-8
GEO 500-2GXV 40-9

12

00

800

GXC, GXV
Submersible sewage and drainage pumps in chrome-nickel stainless steel, with vertical delivery port.
GXC, with single-channel impeller.
GXV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n 2900 rpm).
GXC, GXV:
three-phase 400 V +/-10%;
GXCM, GXVM: single-phase 230 V +/-10%, with thermal protector and incorporated capacitor (without
float switch).
Cable length 10 m.
Liquid temperature up to 35 C
U.S. g.p.m.

40

60

80

100

U.S. g.p.m.

120

30

40

50

60

70

80

90

100

37

10

14

30
40

12

m
10

ft

GX
8

GX

C4

0-1

30

C4

0-1

ft

H
m

GX GXV
4
V4
0-8 0-9
V4
0-7

20

GX

20
4
10

4
10

0
0

m 3/h

12

18

24

30

l/min

100

200

300

400

500

0
0

m 3/h

12

18

l/min

100

200

300

24
400
72.918-N

337

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GQG

Features
Automatic sewage water collecting and lifting station with grinder pumps
GQG series.

It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 electric control box (with capacitor for single-phase motors)
2 duck foot coupling kit
2 discharge pipe kit 63 mm in PVC with a ball valve and non-return ball
valve

On demand
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extension 300 mm

GEO 500-2GQGM 6-18


GEO 500-2GQGM 6-21
GEO 500-2GQGM 6-25

0,9x2
1,1x2
1,5x2

Q max
m3/h

7x2
7,5x2
9,5x2

3 ~ 400 V
kW
A

Three-phase type
GEO 500-2GQG 6-18
GEO 500-2GQG 6-21
GEO 500-2GQG 6-25

0,9x2
1,1x2
1,5x2

13,2x2
15x2
16,8x2
Q max
m3/h

2,3x2
2,8x2
3,8x2

13,2x2
15x2
16,8x2

H max
m
16,5
19,2
23
H max
m
16,5
19,2
23

710

1 ~ 230 V
kW
A

Single-phase type

12

00

800

GQG
Submersible pumps with high power grinder, with horizontal delivery port.
2-pole induction motor, 50Hz (n 2900 rpm)
GQG:
three-phase 400 V +/-10%;
GQGM: Single-phase 230 V +/-10% complete control box with thermal protector and capacitors
(without float switch).
10 m cable.
Liquid temperature up to 35 C.

0 U.S. g.p.m. 10

20

30

40

50

60

70

30
90

GQG
80

6-25

70
20

6-21

6-18

60
m

50
ft
40

10
30
20
10
0
0
0

m3/h

Q l/min

5
50

10
100

150

338

200

15

18

250

300

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GQS

Features
Automatic waste water collecting and lifting station GQS series.

It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
2 discharge pipe kit 63 mm in PVC with a ball valve and non-return
ball valve

On demand

1 ~ 230 V
kW
A

Single-phase type

Q max
m3/h

GEO 500-2GQSM 50-8


GEO 500-2GQSM 50-9
GEO 500-2GQSM 50-11
GEO 500-2GQSM 50-13
GEO 500-2GQSM 50-15

0,55x2
0,75x2
0,9x2
1,1x2
1,5x2

Three-phase type

3 ~ 400 V
kW
A
0,55x2
1,5x2
0,75x2
1,8x2
0,9x2
2,3x2
1,1x2
3x2
1,5x2
4x2

GEO 500-2GQS 50-8


GEO 500-2GQS 50-9
GEO 500-2GQS 50-11
GEO 500-2GQS 50-13
GEO 500-2GQS 50-15

4,3x2
4,8x2
6,6x2
8,4x2
12x2

24x2
27x2
33x2
36x2
36x2

H max
m
7,4
8,8
10,5
12,5
14,4

Q max
m3/h
24x2
27x2
33x2
36x2
36x2

H max
m
7,4
8,8
10,5
12,5
14,4

710

1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm

12

00

800

GQS
Single-impeller submersible pumps, with vertical delivery port.
GQS: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n 2900 rpm)
GQS:
three-phase 400 V +/-10%;
GQSM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float switch).
10 m cable.
Liquid temperature up to 35 C

0 U.S. g.p.m. 20

40

60

80

100

120

140

18

37

H
50

m
14

GQS,

12

GQS
, GQV

10

GQS,
GQV

GQS
, GQV

GQS
, GQ
V 50
-8

ft

GQV 5

0-15

40

50-13
50-11

30

50-9
20

4
10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

339

400

30
500

0
36
600

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GQV

Features
Automatic waste water collecting and lifting station with GQV pump series.

It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box
2 duck foot coupling kit
2 discharge pipe kit 63 mm in PVC with a ball valve and non-return
ball valve

On demand

Q max
m3/h

GEO 500-2GQVM 50-8


GEO 500-2GQVM 50-9
GEO 500-2GQVM 50-11
GEO 500-2GQVM 50-13
GEO 500-2GQVM 50-15

0,55x2
0,75x2
0,9x2
1,1x2
1,1x2

Three-phase type

3 ~ 400 V
kW
A
0,55x2
1,5x2
0,75x2
1,8x2
0,9x2
2,3x2
1,1x2
3x2
1,5x2
4x2

GEO 500-2GQV 50-8


GEO 500-2GQV 50-9
GEO 500-2GQV 50-11
GEO 500-2GQV 50-13
GEO 500-2GQV 50-15

4,3x2
4,8x2
6,6x2
8,4x2
12 x2

24x2
27x2
33x2
36x2
36x2

H max
m
7,4
8,8
10,5
12,5
12,5

Q max
m3/h
24x2
27x2
33x2
36x2
36x2

H max
m
7,4
8,8
10,5
12,5
14,4

710

1 ~ 230 V
kW
A

Single-phase type

1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm

12

00

800

GQV
Single-impeller submersible pumps, with horizontal delivery port.
GQV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n 2900 rpm)
GQV:
three-phase 400 V +/-10%;
GQVM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float switch).
10 m cable.
Liquid temperature up to 35 C

0 U.S. g.p.m. 20

40

60

80

100

120

140

18

H
50

m
14

GQS,

12

GQS
, GQV

10

GQS,
GQV

GQS
, GQV

GQS
, GQ
V 50
-8

ft

GQV 5

0-15

40

50-13
50-11

30

50-9
20

4
10
2
0
0
0

m3/h

Q l/min

10
100

20
200

300

340

400

30
500

0
36
600

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GM..

Features
Automatic waste water collecting and lifting station GMV, GMC series.

It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
2 discharge pipe kit 63 mm in PVC with a ball valve and non-return
ball valve

On demand

Single-phase type
GEO 500-2GMCM 50CE
GEO 500-2GMCM 50BE
GEO 500-2GMVM 50CE
GEO 500-2GMVM 50BE
Three-phase type
GEO 500-2GMC 50CE
GEO 500-2GMC 50BE
GEO 500-2GMC 50AE
GEO 500-2GMV 50CE
GEO 500-2GMV 50BE
GEO 500-2GMV 50AE

1 ~ 230 V
kW
A
0,75x2
4,5x2
1,1x2
6,5x2
0,75x2
4,5x2
1,1x2
6,5x2

Q max
m3/h
36x2
42x2
31x2
35x2

H max
m
9,5
12,5
8
9,5

3 ~ 400 V
kW
A
0,75x2
1,9x2
1,1x2
2,7x2
1,5x2
3,8x2
0,75x2
1,9x2
1,1x2
2,7x2
1,5x2
3,8x2

Q max
m3/h
36x2
42x2
48x2
31x2
35x2
39x2

H max
m
9,5
12,5
14,5
8
9,5
11,5

710

1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm

12

00

800

GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n 2900 rpm)
GMV, GMC:
three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V 10%, built-in thermal protector and built-in capacitor.
(without float switch)
Cable length 10 m.
Liquid temperature up to 35 C.
0

U.S. g.p.m. 50

100

150

200

20

U.S. g.p.m.

50

100

150

13

60

m
16

GMC

40

10

ft

ft

GMV

30

A
40

12

A
B
6

B
C

20

20

8
4

10

4
2

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

42
700

0
48
800

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

0
42
700
72.868.C

341

37

GEO 500

Automatic waste water collecting


and lifting station

Pumps characteristics
GEO 500-2GM..

Features
Automatic waste water collecting and lifting station GMV, GMC series.

It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
2 duck foot coupling kit
2 discharge pipe kit 63 mm in PVC with a ball valve and non-return
ball valve

On demand

Single-phase type
GEO 500-2GMCM 50-65C
GEO 500-2GMCM 50-65B
GEO 500-2GMVM 50-65C
GEO 500-2GMVM 50-65B
Three-phase type
GEO 500-2GMC 50-65C
GEO 500-2GMC 50-65B
GEO 500-2GMC 50-65A
GEO 500-2GMV 50-65C
GEO 500-2GMV 50-65B
GEO 500-2GMV 50-65A

1 ~ 230 V
kW
A
0,75x2
4,5x2
1,1x2
6,5x2
0,75x2
4,5x2
1,1x2
6,5x2

Q max
m3/h
36x2
42x2
31x2
35x2

H max
m
9,5
12,5
8
9,5

3 ~ 400 V
kW
A
0,75x2
1,9x2
1,1x2
2,7x2
1,5x2
3,8x2
0,75x2
1,9x2
1,1x2
2,7x2
1,5x2
3,8x2

Q max
m3/h
36x2
42x2
48x2
31x2
35x2
39x2

H max
m
9,5
12,5
14,5
8
9,5
11,5

710

1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm

12

00

800

GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n 2900 rpm)
GMV, GMC:
three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V 10%, built-in thermal protector and built-in capacitor.
(without float switch)
Cable length 10 m.
Liquid temperature up to 35 C.
0

U.S. g.p.m. 50

100

150

200

20

U.S. g.p.m.

50

100

150

13

60

m
16

GMC

40

10

ft

ft

GMV

30

A
40

12

A
B
6

B
C

20

20

8
4

10

4
2

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

42
700

0
48
800

0
0

m /h

Q l/min

12
200

18
300

24
400

30
500

36
600

0
42
700
72.868.C

342

GEO

Automatic waste water collecting


and lifting station

Dimensions and weights

GEO 40

370

330

Serbatoio
Tank
kg. 6
kg.6

130

B
315

335

415

4.93.433

300

350

340

A) Arrangement for :
40 mm inlet
40 mm outlet
25 mm relief
B) Cable passage with Shuko plug

390

580

GEO 230

485

Prolunga
Extention

300

kg. 4,5
kg.4,5

E
450

545

Serbatoio
Tank

kg. 16
kg.16

C
15

37

570

510

125 125
420

710

4.93.373

600

125 125

800

A-C)
B)
D)
E)

inlet and relief


delivery outlet
G 1 1/2 draining outlet
Cable outlet

C
A
D

97

343

GEO

Automatic waste water collecting


and lifting station

Dimensions and weights


580

Extention
Prolunga
kg. 4,5 kg. 4,5

485

300

GEO 500

Tank
Serbatoio
kg. 32 kg. 32
600

545

450

450

B
C

710

15

B
C

510

570
420

125 125

125 125

C
A
C
4.93.389

800

1200

125

125

97

125 125

A-C)
B)
D)
E)

inlet and relief


delivery outlet
G 1 1/2 draining outlet
Cable outlet

A
D

Installation examples

4.93.267

344

GEO

Technical appendix
Tabella
1 1
Table
Maximum
domestic
waste water
at peak
demand
Portata
massimaflow
delleofacque
domestiche
di rifiuto
nell'ora
di punta

LIFTING STATION SIZING

100

Qr (m3/h)

Normally the domestic waste water flows by gravity into the


mains sewage collectors.
If there are underground rooms with discharge positions
below the sewage main, a lifting station with one or more
pumps may be required.
It is necessary to remember that the UNI-EN 12056-4
standard allows rainwater to be pumped to the sewage
main only in exceptional cases.
To sizing a lifting station pump it is necessary to calculate
the flow Qtot and the Head hmt necessary for the water
drainage.

10

B
A

C
D

FLOW CALCULATION

The flow of the lifting pumps can be calculated using Table1,


according to the number of people using the building and
the location of the building. It is easy to calculate the flow Qr
of the sewage water.
The Qr value is already adjusted by a coefficient that
includes the peak hours, when the water consumption is
higher.
The lifting systems of waste water are usually separated
from the rainwater system. In case of a mixed system is
required to sum the flow Qm of the rainwater of the Table 2
with the flow Qr of the Table 1.

persons (no.)
persone
(n)

100

1000

A Houses ----BB Hospitals ----C


C Industry ----D
D Offices
----A
abitazioni

ospedali

Industrie 2)

uffici

Tabella22
Table
Rainwater
Flow
Portata
delle acque
meteoriche

100

The table indicates the rainwater flow Qm as a function of


the exposed surface to rainfall, it varies according to the
capacity of the surface to absorb rain water (Table 3).
The total flow of the pump or pumps is:

10
Qm (m3/h)

Qtot = Qr + Qm

10

C
D

HEAD CALCULATION
To calculate the head hmt it is necessary to add the
geodetic head existing between the fluid levels with the
head losses from internal friction created by the flow of the
fluid in the hydraulic pipes and fittings (Figure 1).

0,1
10

After the choice of the discharge pipe diameter, such that


the flow speed it is not lower than 0,7 m/s (to avoid
deposits) and higher than 2,3 m/s, it is possible to
determine the distributed head loss Hd and concentrated
head loss Hv Hc, due to valves and curves (Table 4).

20

60 80 100
area (m2(m
) 2)
superficie

200

400 600 800 1000

B on sand ----C Cgravel/pebbles ----D


D
----A Aroofs ----B stone
gardens

Piazzali-tetti

Pietra su sabbia

Figure 1

Pc

The sum of the head losses DPC is:

pc = Hd+Hv+ Hc

1) Water arriving from sinks discharge, toilets, showers, washing machines etc.
2) Excluding consumption from industrial processes.
3) The unit flow reference is 1,5 l/min/m2

345

Hg

Hmt

The total head hmt is calculated as:

Hmt = Hg + pc

40

Ciottoli -ghiaia

giardini

37

GEO

Technical appendix
Tabella 4
Table no. 4
Head
loss curve
in cme saracinesche
for bends and
Perdite delle
(cm) gate valves

Table no. 3
Tabella 3
Head loss
in mnei
fortubi
PVC
PN6PN6
(m)(m)
pipes
Perdite
di carico
in PVC
1,8

3,6

5,4

7,2

18

27

36

50,4

64,8

30

60

90

120

150

300

450

600

840

1080 1500 2100 2700 3000

50

0,24

0,85

1,8

3,1

4,6

16,7

35,3

0,30

0,59

0,89

1,18

1,48

2,96

4,44

63

0,08

0,26

0,56

0,95

1,11

5,2

10,9

18,6

34,8

e mm

Q l/min

0,18

90

126

162

180

ad
= 90
sweep
elbow = 90
Curve
angolo
arrotondato
Velocit
Water
dell'
flow
acqua
velocity

0,37

0,55

0,73

0,92

1,83

2,75

3,66

5,13

75

0,11

0,24

0,4

0,61

2,2

4,6

7,9

14,7

23,4

43

0,26

0,39

0,51

0,64

1,29

1,93

2,57

3,6

4,63

6,43

m/sec.

90

0,05

0,1

0,16

0,25

0,9

1,9

3,3

6,1

9,7

17,8

33,2

0,4

0,11

0,13

0,18

0,27

0,36

0,45

0,89

1,34

1,79

2,5

3,22

4,47

6,26

0,04

0,06

0,09

0,3

0,67

1,15

2,15

3,4

6,25

11,7

18,5

22,5

0,5

0,18

0,21

0,17

0,2

0,29

0,58

0,87

1,16

1,63

2,10

2,91

4,08

5,24

5,82

0,6

0,25

0,03

0,05

0,17

0,36

0,6

1,15

1,84

3,37

6,3

10

12,2

0,7

0,18

0,23

0,45

0,68

0,90

1,26

1,63

2,26

3,16

4,06

4,52

110
125
HL
v

140
160
180

m/100m
m/s

200
225
250
280

Gate
Saracivalves
nesche

Tubo PVC
PVC
pipe Q m3/h
PN6
PN6

d
d
d
= 0,4
= 0,6
= 0,8
R
R
R

d
=1
R

d
= 1,5
R

0,16

0,23

0,43

0,23

0,26

0,37

0,67

0,37

0,29

0,36

0,52

0,97

0,52

0,34

0,40

0,48

0,70

1,35

0,70

0,8

0,45

0,53

0,64

0,93

1,7

0,95

0,03

0,1

0,2

0,35

0,65

1,05

1,95

3,6

5,77

0,18

0,36

0,54

0,72

1,01

1,30

1,80

2,52

3,24

3,60

0,9

0,57

0,67

0,82

1,18

2,2

1,20

0,05

0,11

0,18

0,34

0,55

1,02

1,9

3,66

1,0

0,7

0,82

1,0

1,45

2,7

1,45

0,28

0,41

0,55

0,77

0,99

1,38

1,93

2,48

2,76

0,03

0,06

0,1

0,19

0,31

0,57

1,06

1,69

2,05

1,5

1,6

1,9

2,3

3,3

3,3

0,22

0,33

0,43

0,61

0,78

1,09

1,52

1,96

2,17

2,0

2,8

3,3

4,0

5,8

11

5,8

0,02

0,04

0,06

0,12

0,18

0,34

0,64

1,23

2,5

4,4

5,2

6,3

9,1

17

9,1

0,18

0,26

0,35

0,49

0,63

0,88

1,23

1,59

1,76

0,02

0,04

0,07

0,1

0,19

0,36

0,57

0,7

3,0

6,3

7,4

13

25

13

0,21

0,28

0,39

0,55

0,70

0,97

1,25

1,39

3,5

8,5

10

12

18

33

18

0,02

0,04

0,06

0,12

0,22

0,34

0,42

4,0

11

13

16

23

42

23

0,23

0,32

0,41

0,56

0,79

1,02

1,13

0,01

0,02

0,04

0,07

0,13

0,2

0,24

4,5

14

21

26

37

55

37

0,18

0,25

0,32

0,45

0,63

0,81

0,90

5,0

18

29

36

52

67

52

84
1400

96
1600

EXAMPLE OF CALCULATION
Suppose it is required to size a lifting station, for a residential building where 80 people live.
The pumps will have to lift waste water up to an additional tank located 5m higher, the linear distance between the 2 tanks is 70 m.
In addition the station will receive rainwater from 400 m2 of tarmac, roof surfaces and 120 m2 of garden.
Considering:

Q tot = Qr + Qm
20

It is possible to calculate the Qr from the Table1 which is 4 m3/h, while Qm is obtained from the Table 2 and is 36 m3/h ( roofs and tarmac) plus 2 m3/h from gardens,
with this value Qtot is 42 m3/h. At this flow it will be necessary split the flow between
two pumps.
We choose a delivery pipe diameter such that the flow rate with two pumps in operation does not exceed 2.3 m / sec and not be lower than 0.7 m / s with a single
pump.
From (Table 3) we obtain:
42 m3/h => 1,4 m/s => TUBO DN 110 (with two pumps in parallel operation)
21 m3/h => 0,7 m/s => TUBO DN 110 (with one operating pump)

H
m
16

GMC

12

dutydipoint
punto
lavoro

2GMCM 50-65B
X

The distributed head loss in 70 m pipe with 720 l / min is 1.13 m (Table 3), then
from the formula:

1GMCM 50-65B
0

Hmt = Hg + pc

0
0

m /h

Q l/min

24
400

36
600

48
800

60
1000

72
1200

It is obtained Hmt = 6,13 mca


he suitable pumps are no. 2 GMCM 50-65B and then it result a station type GEO 500-2GMCM 50-65B.

INSTALLATION EXAMPLE

4.93.267

346

09/2016

MP

Multi-stage submersible pumps


Construction
Multi-stage centrifugal submersible pumps with pump jacket in
chrome-nickel stainless steel, with vertical delivery port.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.

Applications
- For clean water containing solids up to 2 mm grain size.
- For draining rooms or or emptying tanks.
- Extraction of water from ponds, streams or pits and for
rainwater collection.
- For irrigation purposes.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60 335-2-41.

Operating conditions
Liquid temperature up to 35 C.
Maximum immersion depth: 5 m.
Minimum water level with float 100 mm.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).
MP:
three-phase 230 V 10%;
three-phase 400 V 10%;
MPM: single-phase 230 V,
with float switch and thermal protector.
Incorporated capacitor.
Insulation class F.
Protection IP X8 (for continuous immersion)
Double impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.

Materials
Component
Pump casing
Impeller
Stage casing
Motor jacket
Pump jacket
Strainer
Handle
Shaft
Mechanical seal
Seal lubrication oil

Material
PPO-GF20 (Noryl)

Other features on request

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Other mechanical seal.
- Cable length 10 m.
- Vertical magnetic float switch.
- Motor suitable for operation with frequency converter.

Polypropylene
Chrome-nickel steel 1.4305 EN 10088 (AISI 303)
Ceramic alumina/Carbon/NBR
Oil for food/pharmaceutical machinery

Coverage chart n 2900 rpm


0

U.S. g.p.m.

10

30

20

MP

30

80
MP 203

H
ft

20

60

H
m
MP 202

MP 402

40

10
MP 401

MP 201

0
0

m3/h
Q l/min

l/s

2,5
25

5
50

0,5

20

75
1

347

7,5
125

100
1,5

38

MP

Multi-stage submersible pumps

Performance n 2900 rpm


3~

MP 201

230V 400V
A

1,6

0,9

1~

230V Capacitor

P1

Vc

kW

kW

450

0,5

0,25 0,34

A
2,3

MPM 201

HP

MP 202

1,6

0,9

MPM 202

2,3

450

0,5

0,25 0,34

MP 203

2,3

1,3

MPM 203

3,5 12,5 450

0,7

0,37

3~

230V 400V
A

1~

P2

230V Capacitor

MP 401

1,6

0,9

MP 402

2,3

1,3

Vc
8

kW

kW

1,5

16,6

10,5
20,7

0,5

HP

2,3

450

0,5

0,25 0,34

MPM 402

3,5 12,5 450

0,7

0,37

0,5

3,5

25

33,3 41,6

50

9,2

8,5

7,8

7,1

18

16,7 15,3 13,7

Power supply cable


Cable material

Section

Length

3,7

2,7

6,4

4,4

7,2

3,5

58,3 66,6

83,3 100 120

6,2

4,8

3,3

16,7 15,8 14,8 13,6 12,5

10

6,5

50

9,2

8,5

20,8

18

YES

H07RN-F

3G1 mm2

MPM 203,402

H07RN-F

3G1 mm2

5m

YES

H07RN-F

3G1 mm2

MP 201,202,401

H05RN-F

4G0,75 mm2

5m

NO

NO

MP 203,402

H07RN-F

4G1 mm2

5m

NO

NO

Dimensions and weights

fM

4.93.388

176
ISO 228

56
(1)
kg

fM

MP

MPM

MP 201 - MPM 201

265

230

4,7

4,9

MP 202 - MPM 202

290

255

4,8

5,2

MP 203 - MPM 203

350

315

6,4

6,7

MP 401 - MPM 401

265

230

4,7

4,9

MP 402 - MPM 402

325

290

6,4

4,5
75

37,5

5m

6,8

0
10,6

3G0,75 mm2

G 1 1/4

4,6

10,2 8,4

H05RN-F

348

5,5

12

Section

(1) With cable length: 5 m

6,3

2,25

Cable material

Dimensions
mm

83,3

MPM 201,202,401

TYPE

75

CEE 7(VII)

58,3 66,6

10

Float switch
Plug

13

Tolerances according to UNI EN ISO 9906:2012

Pump
type

4,5

16

Density = 1000 kg/m3.

P2 Rated motor power output.

27,5 25,5 23,5 21,2 18,6

l/min

2,5

31

m 3/h

MPM 401

P1 Max. power input.

l/min

P2

P1

m 3/h

7,4

Kinematic viscosity = max 20 mm2/sec.

MP

Multi-stage submersible pumps

Installation examples

G 1 1/4
ISO 228

On

mm

TYPE

h min h max

h
max

fM

Off
h
min

MPM 201

100

310

MPM 202

125

335

MPM 203

185

395

MPM 401

100

310

MPM 402

160

370

3.93.037/3

176
min 350 x 350

Installation examples with vertical magnetic float switch

mm

TYPE

h min h max

h
min

h fM
max

3.93.037/3

176
min 250 x 250

349

MPM 201 GF

100

190

MPM 202 GF

125

315

MPM 203 GF

185

275

MPM 401 GF

100

190

MPM 402 GF

160

250

38

MP

Multi-stage submersible pumps

Features

G 1 1/4 vertical, upward delivery port for installation in


small pits, without the need for an elbow on the pump.

Handle in polypropylene.

Easy inspection of the


capacitor area.

Shaft in chrome-nickel
stainless steel.
Easy adjustment of the
float switch: to allow the
adjustement of start/stop
pump levels.

Motor cooled by the pumped


water passing between the
motor jacket and the external
jacket.

Ceramic stainless steel shaft


sleeve.

Oil chamber.

Stage casing and Impeller in PPO-GF20 (Noryl)

Suction strainer that allows the passage


of solids up to 2 mm.

The double shaft seal with oil chamber separates the


motor from the water and provides further protection
against accidental operation when dry.

350

09/2016

MPS

Multi-Stage Submersible Clean Water Pumps

Construction
PATENTED

Close coupled multi-stage submersible pumps.


External jacket in stainless steel AISI 304 and stages Noryl.
MPSM with built-in capacitor, accessible through the delivery
casing.
Hydraulics located below the motor with the motor cooled by
the pumped fluid. Safe operation is possible with the motor
only partially submerged.
Double shaft seal with oil chamber.
The suction strainer prevents the entrance of solids with diameter bigger than 2 mm.

Applications
For water supply from wells, tanks or reservoirs.
For domestic, civil and industrial applications, for garden use,
irrigation and rain water harvesting systems.

Operating conditions
Water temperature up to 35 C.
Minimum internal diameter of well: 140 mm.
Minimum immersion depth: 100 mm.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 1/min).
MPS : three-phase 230 V 10%;
three-phase 400 V 10%.
Cable: H07RN8-F, length 15 m, without plug.

Materials
Component

Material

Delivery casing
External jacket
Suction strainer
Motor jacket
Stage casing
Impeller
Shaft
Capacitor cover
Oil chamber cover
Preload ring stages
Support ring preload
Upper mechanical seal
Lower mechanical seal
Seal lubrication oil

MPSM : single-phase 230 V 10%, with thermal protector.


Incorporated capacitor.
Float switch MPSM.. CG (on demand)
Cable: H07RN8-F, length 15 m, with plug CEI-UNEL 47166.

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Insulation class F.
Protection IP 68 (for continuous immersion).
Double impregnation humidity-proof dry winding.
Constructed in accordance with EN 60335-2-41.

PPO-GF20 (Noryl)
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
PPS Polymer (Grivory)

Special features on request

Steatite, carbon, NBR


Carbon, silicon carbide, NBR
Oil for food machinery and pharmaceutic use

- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Cable length 20 m.
- Motor suitable operation with frequency converter.

Coverage chart n 2900 rpm

100

U.S. g.p.m.

Imp g.p.m.

10

30

20
10

20

40
30
300

90

ft
80

250

70

200

m
50

150
40

MPS 3

30

100

MPS 5

20
50
10
0

0
0

m3/h
l/min

6
100

50

10
150
72.986/1

351

39

MPS

Multi-Stage Submersible Clean Water Pumps

Performance n 2900 rpm


Capacitor

P1

kW

kW

HP

MPSM 303
MPSM 304
MPSM 305
MPSM 306
MPSM 307

3,5
4,1
5
6
6,6

14
20
20
25
25

450
450
450
450
450

0,8
0,9
1,1
1,3
1,5

0,45
0,55
0,75
0,9
0,9

0,6
0,75
1
1,2
1,2

1~

230 V

Capacitor

P1

230 V 400 V

3~

MPS 303
MPS 304
MPS 305
MPS 306
MPS 307

2,4
2,8
3,3
3,8
4,5

1,4
1,6
1,9
2,2
2,6

1~

230 V 400 V

3~

MPS 503
MPS 504
MPS 505
MPS 506
MPS 507

2,8
3,8
4,5
4,8
6,8

1,6
2,2
2,6
2,8
3,9

P1 Max. power input.

MPSM 503
MPSM 504
MPSM 505
MPSM 506
MPSM 507

230 V

P2

P2

kW

kW

HP

4,1
6
7
8,3
12

20
25
25
30
35

450
450
450
450
450

0,9
1,2
1,5
1,7
2,2

0,55
0,9
1,1
1,1
1,5

0,75
1,2
1,5
1,5
2

P2 Rated motor power output.

l/min

1,5

2,5

3,5

4,5

16,6 25 33,3 41,6 50 58,3 66,6 75

32,5
44
53
65
77,5

29,5
41,5
49,5
61
71

27,5
39,5
47
58
66,5

25,5
36,5
44
54
61

23
33,5
40
49
55

19,5
29,5
35
43
49

17
25,5
30
37
42

13
21
25
30,5
35

10
16
19
23
27

m3/h

2,5

3,5

4,5

l/min

41,6 50 58,3 66,6 75 83,3 100 116 133

Hm

m3/h

Hm

32,2
43
53
66,5
78,5

Tolerances according to UNI EN ISO 9906:2012

28,5
39
47,5
58
69,5

27,5
38
45,5
55,6
66,5

26
36,5
43,5
53,5
64

24,5
34,5
41
51
61,5

22,5
33
38,5
48
58

21,5
30,5
35,5
45
54,5

18
25,5
29,5
36,5
45,5

13,5
19,5
22
27,5
36

8
13
13,5
16
22

Test results with clean cold water, without gas content.

Dimensions and weights


G 1 1/4
ISO 228

Weights

with cable length: 15 m


fM

Pump

mm

fM

kg
MPS

MPSM

Cable
Cavo H07RN8-F
230V
230V
1~
3~

400V
3~

MPS 303 - MPSM 303

465

11

12

3G1 mm2

4G1 mm2

4G1 mm2

MPS 304 - MPSM 304

504

11,5

12,5

3G1 mm2

4G1 mm2

4G1 mm2

MPS 305 - MPSM 305

553

12

13

3G1 mm2

4G1 mm2

4G1 mm2

15

3G1

mm2

4G1

mm2

4G1 mm2

mm2

4G1

mm2

4G1 mm2

MPS 306 - MPSM 306

577

13,5

MPS 307 - MPSM 307

601

14

15,5

3G1

MPS 503 - MPSM 503

480

11,5

12,5

3G1 mm2

4G1 mm2

4G1 mm2

MPS 504 - MPSM 504

529

13,5

14,5

3G1 mm2

4G1 mm2

4G1 mm2

MPS 505 - MPSM 505

553

14

15

3G1 mm2

4G1 mm2

4G1 mm2

MPS 506 - MPSM 506

622

15,5

17

3G1,5 mm2

4G1 mm2

4G1 mm2

mm2

mm2

4G1 mm2

MPS 507 - MPSM 507


133

MPSM ... CG
With float switch pump
(on demand)

352

671

17

18,5

3G2,5

4G1

MPS

Multi-Stage Submersible Clean Water Pumps

Characteristic curves n 2900 rpm


0

Imp g.p.m.

10

15

120

110

Imp g.p.m.

10

20

350

100

MPS 5

110

MPS 3

90

350

100

300

300

90

80
250

80
H
70
m
60

307

70
m

306

60

200
ft

305

50
40

303

30

507
200

506

50

150

304

250

100

20

ft

505

40

504

30

503

150

100

20
50

50

10
0

10

0
0

m 3/h

0
1

2
20

l/min

3
40

4
60

80

40

50

30

40

Q m3/h

72.987.1

m3/h

0
2
50

l/min

Q m3/h

100

72.988

39

353

MPS

Multi-Stage Submersible Clean Water Pumps

Features
PATENTED
Innovative

Robust

Designed to withstand water hammering and


the ON-OFF operation of any valve located in
the discharge line.
The impacts generated by water hammering
or by the closing of the valve are fully
supported by the capacitor cover,which
relieves the stresses on a specific support
made on the stainless steel jacket, without
affecting the plastic hydraulic part.

Its robust stainless steel external


construction allows for the pump to
be suspended from the delivery
pipe.

Low-Noise operation
The design of hydraulic parts, the
water-filled shroud around the
motor and the submerged operation ensures low noise operation.

Flexible
Allows the inspection of the capacitor
without disassembling the pump, through
the delivery casing.

Reliable
The ball bearings and shaft are sized in
order to reduce stresses, guaranteeing
high reliability in any operating condition.

Greater Safety

Low cost installation

The double shaft sealing with an oil


chamber separates the motor from
the water and provides further protection against accidental operation when dry.

Immersed, without suction pipe and valves.


The cylindrical suction strainer provides
support for the pump when installed on a
flat surface or tank bottom. For operation
with 100 mm minimum water level.

Installation

0.5 m
min

Off

Off

max 20 m

Max. 1000 mm

140 mm
min
3.93.007/1

Pump in suspended position

3.93.007/3

3.93.007/2

Pump with float switch (on demand)


354

Installation example

09/2016

MXS

Multi-Stage Submersible Clean Water Pumps


in stainless steel
Construction

PATENTED

Close coupled multi-stage submersible pumps.


All parts in contact with the fluid both internal and external
are in chrome-nickle stainless steel.
MXSM with built-in capacitor, accessible through the delivery casing.
Hydraulics located below the motor with the motor cooled by
the pumped fluid. Safe operation is possible with the motor
only partially submerged.
Double shaft seal with oil chamber.
The suction strainer prevents the entrance of solids with diameter bigger than 2 mm.

Applications
For water supply from wells, tanks or reservoirs.
For domestic, civil and industrial applications, for garden use,
irrigation and rain water harvesting systems.

Operating conditions
Water temperature up to 35 C.
Minimum internal diameter of well: 140 mm.
Minimum immersion depth: 100 mm.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 1/min).
MXS : three-phase 230 V 10%;
three-phase 400 V 10%.
Cable: H07RN8-F, length 15 m, without plug.

Materials
Component

Material

Delivery casing
External jacket
Suction strainer
Stage casing
Spacer sleeve
Impeller
Motor jacket
Jacket cover
Oil chamber cover
Shaft
Upper mechanical seal
Lower mechanical seal
Seal lubrication oil

MXSM : single-phase 230 V 10%, with thermal protector.


Incorporated capacitor.
Float switch MXSM.. CG up to 10A (on demand)
Cable: H07RN8-F, length 15 m, with plug CEI-UNEL 47166.

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Insulation class F.
Protection IP 68 (for continuous immersion).
Double impregnation humidity-proof dry winding.
Constructed in accordance with EN 60335-2-41.

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)


Steatite, carbon, NBR
Ceramic alumina, silicon carbide, NBR
Oil for food machinery and pharmaceutic use

Special features on request


- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
- Cable length 20 m.
- Motor suitable operation with frequency converter.

Coverage chart n 2900 rpm


0

U.S. g.p.m.

Imp g.p.m.

10

30

20
10

50

40

20

30

40

120
110

350

100
300

90

ft
80

250

70

MXS 3

200
MXS 9

MXS 5

50

150
40
100

30
20

50
10
0

0
0

m3/h
l/min

4
50

6
100

10
150

0
12
200
72.986/1

355

40

MXS

Multi-Stage Submersible Clean Water Pumps


in stainless steel

Performance n 2900 rpm


230 V 400 V

3~
MXS 303
MXS 304
MXS 305
MXS 306
MXS 307
MXS 308
MXS 309
MXS 310

2,4
2,8
3,3
3,8
4,5
4,8
6,6
7,5

1,4
1,6
1,9
2,2
2,6
2,8
3,8
4,3

1~

230 V

MXSM 303
MXSM 304
MXSM 305
MXSM 306
MXSM 307
MXSM 308
MXSM 309
MXSM 310

A
3,5
4,1
5
6
6,6
8,3
9
12

1~

230 V

230 V 400 V

3~

Capacitor

P1

F
14
20
20
25
25
30
30
35

V
450
450
450
450
450
450
450
450

kW
0,8
0,9
1,1
1,3
1,5
1,7
1,9
2,2

Capacitor

P1

V
450
450
450
450
450
450
450

kW
0,9
1,2
1,5
1,7
2,2
2,4
2,9

MXS 503
MXS 504
MXS 505
MXS 506
MXS 507
MXS 508
MXS 509
MXS 510

A
2,8
3,8
4,5
4,8
6,8
7,5
9,7
9,7

A
1,6
2,2
2,6
2,8
3,9
4,3
5,6
5,6

MXSM 503
MXSM 504
MXSM 505
MXSM 506
MXSM 507
MXSM 508
MXSM 509

A
4,1
6
7
8,3
12
13
14,3

3~

230 V

400 V

1~

230 V

Capacitor

P1

MXS 903
MXS 904
MXS 905
MXS 906
MXS 907
MXS 908
MXS 909
MXS 910

A
4,5
6,6
7,5
9,7
11,4
14,7
14,7
14,7

A
2,6
3,8
4,3
5,6
6,6
8,5
8,5
8,5

MXSM 903
MXSM 904
MXSM 905
MXSM 906

A
7
9
13
14,3

F
25
30
35
40

kW
1,5
1,9
2,4
2,9

P1 Max. power input.

P2 Rated motor power output.

F
20
25
25
30
35
35
40

V
450
450
450
450

P2
kW
0,45
0,55
0,75
0,9
0,9
1,1
1,5
1,5

Q
HP
0,6
0,75
1
1,2
1,2
1,5
2
2

P2
HP

0,55
0,9
1,1
1,1
1,5
1,5
2,2
2,2

0,75
1,2
1,5
1,5
2
2
3
3

P2
HP
1,5
2
3
3
4
4
4
4

1,5

16,6

25

32,5
44
53
65
77,5
88,5
100
111

29,5
41,5
49,5
61
71
81,5
91
101,5

27,5
39,5
47
58
66,5
76
85
95

2,5

33,3 41,6

3,5

50

58,3 66,6

4,5
75

13
10
25,5 23 19,5 17
16
36,5 33,5 29,5 25,5 21
40
35
30
25
19
44
54
49
43
37 30,5 23
61
55
49
42
35
27
70,5 64 56,5 49,5 41
32
78,5 70,5 62,5 54,4 45
35
88,5 80
71
62 52,5 41,5

m 3/h

2,5

3,5

l/min

41,6

50

58,3 66,6

32,2
43
53
66,5
78,5
88,5
101
111

28,5
39
47,5
58
69,5
78
91
100

Hm

kW
1,1
1,5
2,2
2,2
3
3
3
3

l/min

Hm

kW

m 3/h

4,5

75

27,5 26 24,5 22,5


38 36,5 34,5 33
45,5 43,5 41 38,5
48
55,6 53,5 51
66,5 64 61,5 58
68
64
75
72
87,5 84 80,5 75,5
89 84,5
96,5 93

83,3 100

116

133

21,5
30,5
35,5
45
54,5
60
71
80

18
25,5
29,5
36,5
45,5
50
60
66,5

13,5 8
19,5 13
22 13,5
27,5 16
36
22
38
25
46,5 28,5
52
31

10

11

m3/h

l/min

83,3

100

116

133

150

166,6 183,3

26,8
37
46,5
56,5
68,5
78
88
96,5

25,2
35
45
54
66
75
84
93

23,3
32,5
42,5
50,5
62
71
79
87,5

21,2
30
38,5
46,5
58
66
73,5
81,5

18,5
26,5
34
42
53
60,5
67,5
73,5

34
28,2
45,5
39
58
49
70
59,5
81
71
93
81
105
92
117 101,2

Hm

Tolerances according to UNI EN ISO 9906:2012

15,5
22,5
30
37
47
53
57,5
63,5

Test results with clean cold water, without gas content.

Dimensions and weights


G 1 1/4
ISO 228

Weights

with cable length: 15 m


fM

Pump
MXS 303 - MXSM 303

MXSM ... CG
With float switch pump
(on demand)

MXSM

230V
1~

400V
3~

465

12,5

13,5

3G1 mm2

4G1 mm2

4G1 mm2

mm2

mm2

4G1 mm2

504

14,5

15,5

3G1

MXS 305 - MXSM 305

553

15

16,5

3G1 mm2

4G1 mm2

4G1 mm2

MXS 306 - MXSM 306

577

15,5

17

3G1 mm2

4G1 mm2

4G1 mm2

MXS 307 - MXSM 307

601

16

17,5

3G1 mm2

4G1 mm2

4G1 mm2

MXS 308 - MXSM 308

671

18,5

19,5

3G1,5 mm2

4G1 mm2

4G1 mm2

21,6

3G1,5

mm2

3G2,5

mm2

695

20,6

4G1

4G1,5

mm2

4G1 mm2

4G1,5

mm2

4G1 mm2

MXS 310 - MXSM 310

744

23

25,1

MXS 503 - MXSM 503

480

14,5

15,5

3G1 mm2

4G1 mm2

4G1 mm2

MXS 504 - MXSM 504

529

15

16

3G1 mm2

4G1 mm2

4G1 mm2

MXS 505 - MXSM 505

553

16,1

17,6

3G1 mm2

4G1 mm2

4G1 mm2

MXS 506 - MXSM 506

622

17,5

19

3G1,5 mm2

4G1 mm2

4G1 mm2

MXS 507 - MXSM 507

671

20

21,5

3G2,5 mm2

4G1 mm2

4G1 mm2

695

MXS 508 - MXSM 508

133

Cavo H07RN8-F
230V
3~

MXS

MXS 304 - MXSM 304

MXS 309 - MXSM 309


fM

kg

mm

20,5

22

3G2,5

mm2

3G2,5

mm2

4G1,5

mm2

4G1 mm2

4G1,5

mm2

4G1 mm2

4G1,5 mm2

4G1 mm2

MXS 509 - MXSM 509

744

23

MXS 510

768

27

MXS 903 - MXSM 903

523

16,1

17,6

3G1,5 mm2

4G1 mm2

4G1 mm2

MXS 904 - MXSM 904

573

18,2

19,7

3G1,5 mm2

4G1 mm2

4G1 mm2

MXS 905 - MXSM 905

653

19

22

3G2,5 mm2

4G1,5 mm2

4G1 mm2

26

mm2

4G1,5

mm2

4G1 mm2

4G2,5

mm2

4G1 mm2

708

MXS 906 - MXSM 906

23

24,5

3G2,5

MXS 907

738

26,3

MXS 908

793

27

4G2,5 mm2

4G1 mm2

MXS 909

823

28,1

4G2,5 mm2

4G1,5 mm2

MXS 910

853

29,5

4G2,5 mm2

4G1,5 mm2

356

MXS

Multi-Stage Submersible Clean Water Pumps


in stainless steel

Characteristic curves n 2900 rpm


120

Imp g.p.m.

10

15

110

120

300

90

250

80
H
70
m
60

308

307

70
m
60
50

306

200

305

ft

303

30

100

350

510
300

509
508

250

507
200

506

50

150

304

40

20

MXS 5

100

309

80

10

350

310

90

Imp g.p.m.

110

MXS 3

100

ft

505

40

504

30

503

150

100

20
50

20

10
50

10

0
0

m 3/h

2
20

l/min

40

60

80

40

50

30

40

Q m3/h

0 Imp g.p.m. 10

72.987.1

20

30

m3/h

0
2
50

l/min

Q m3/h

100

72.988

40

120

MXS 9

110

910

100

909

90
H
m

300

908
ft

907

70

906

60
50

905

40

904

30

903

200

100

20
10
0
0

m3/h 2
l/min

4
50

100

10

40

12

150

200

60

%
50

Q m3/h 2

10

72.933

12

357

MXS

Multi-Stage Submersible Clean Water Pumps


in stainless steel

Features
PATENTED

Flexible

Robust

Allows the inspection of the capacitor


without disassembling the pump, through
the delivery casing.

Its robust stainless steel


construction allows for the pump
to be suspended from the delivery
pipe.

Reliable
The ball bearings and shaft are sized in
order to reduce stresses, guaranteeing
high reliability in any operating condition.

Low-Noise operation
The design of hydraulic parts, the
water-filled shroud around the
motor and the submerged operation ensures low noise operation.

Totally in stainless stell


All parts in contact with the pumped
liquid both internal and external are in
stainless steel AISI 304, without plastic
materials and components.

Greater Safety

Low cost installation

The double shaft sealing with an oil


chamber separates the motor from
the water and provides further protection against accidental operation when dry.

Immersed, without suction pipe and valves.


The cylindrical suction strainer provides support for the pump when installed on a flat surface or tank bottom. For operation with 100
mm minimum water level.

Installation

0.5 m
min

Off

Off

max 20 m

Max. 1000 mm

140 mm
min
3.93.007/1

Pump in suspended position

3.93.007/3

3.93.007/2

Pump with float switch (on demand)


358

Installation example

09/2016

SFM 70

Peripheral submersible borehole pumps


for 4 wells
Construction
Submersible borehole pumps for 4 deep wells (DN 100 mm),
with turbine impeller.
The special plastic and stainless steel hydraulic materials
prevent the impeller from locking even after long stationary
periods.
Thanks to special construction features, both installation and
maintenance of SFM 70 are fast and easy.
Delivery port G 1.

Applications
For 4 wells.
Pumping clean water into: detached houses, farms and
cottages.
Moving water in fountains.
Rain irrigation.
Feeding pressure systems.
Filling and emptying tanks.

Operating conditions
Water temperature up to 35 C.
Max. sand quantity into the water: 20 g/m3.
Continuous duty.

Motor
2-pole induction motor, 50 Hz (n 2900 rpm).

Materials
Components

Materials

Delivery casing

Nylon PA66 +30% GF


(brass thread inserts)

Upper plate
Lower plate

Ryton R4 with a shim ring in chrome-nickel steel 1.4301


EN 10088 (AISI 304) integrated

Impellers

Brass P-Cu Zn 40 Pb 2 UNI 5705

Shaft

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Shell, filter, locking plugs

Chrome-nickel steel 1.4301 EN 10088 (AISI 304)

Screws steel

A2

SFM 70: single-phase 230 V, with thermal protector.


Incorporated capacitor.
Cable suitable for use with drinking water 3x1,5 + 1G1,5mm2.
Cable length 20 m.
Insulation class F.
Protection IP X8 (for continuous immersion)
Dielectric fluid-cooled motor with compensating diaphragm.
Constructed in accordance with: EN 60335-2-41.

Special features on request


- Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).

Characteristic curve n 2900 rpm


2

0
80

U.S. g.p.m

4
2

10

Imp. g.p.m

12
10

SFM
IM 1070

200

50

H
ft
100

H
m

0
0

m3/h
l/min

20

30
359

40

3
50

41

SFM 70

Peripheal submersible borehole pumps


for 4 wells

Coverage chart n 2900 rpm


1~

230V

SFM 70

P1

P2

kW

kW

HP

5,9

1,4

0,75

P1 Max. power input.

m3/h

0,3

0,6

0,9

1,2

1,5

1,8

2,1

2,4

2,7

l/min

10

15

20

20

30

35

40

45

65

58

52

44

22

14,7

7,6

1,2

P2 Rated motor power output

37,8 30,1

Tolerances according to UNI EN ISO 9906:2012

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3.

Dimensions and weights


95

Weight kg. 11,3

G.1"

560

ISO 228

Features

Optimized hydraulics
The pump hydraulics are designed to ensure
high performance and consistency of
performance.

Reliability
The oil bath motor allows a better lubrication by
increasing the lifetime of all the moving parts
and the copper wires.

Rubustness
The mechanical structure of the hydraulic parts
in contact with the pumped liquid are
dimensioned to guarantee the maximum
resistence to mechanical stress.
Thanks to special construction features, both
installation and maintenance of SFM 70 are fast
and easy.

360

09/2016

SD

Submersible borehole pumps for 4 and 6 wells


Construction
Submersible borehole pumps for 4 wells (DN 100 mm),
and 6 (DN 150 mm), with external jacket in stainless steel AISI
304 and stages in polycarbonate for 4SD pumps and in noryl
for 4SDF, 6SD, 6SDN pumps.
Impellers
radial floating impellers
radial impellers
mixed flow impellers

4SDF 16, 22, 36, 46, 54


4SD 31, - 6SDN 12, 16, 21
4SD 10, 15 - 6SD 18, 19, 20

Connection: screwed connection ISO228.


Delivery casing with built-in non-return valve.

Applications
For water supply.
For civil and industrial applications.
For fire fighting applications.
For irrigation.

Operating conditions
Liquid temperature:

- up to a 35 C for 4 motors
- up to a 25 C for 6-8-10 motors.
Max. sand quantity into the water: 150 g/m3 (300 g/m3 high
percentage of solids and sand).
Continuous duty.

Rewindable motor CSseries


2-pole induction motor, 50 Hz (n 2900 rpm).
Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- single-phase 230 V up to 2,2 kW for 4 motors.
- three-phase 230 V; 400 V, for 4 motors.
- three-phase 400 V; 400/690 V, for 6 motors.
Voltage tolerance : +6% / -10%.
In order to limit both current and torque at each starting, for
rated motor powers equal to or higher than 7.5 kW, one of the
following types of starting is necessary: star/delta, soft starter,
stator impedance or autotransformer.

Operating conditions motor


The electropumps 4SD, 4SDF, 6SDN series comply with the European Regulation
no. 547/2012, (6SD 18,19,20 series cannot be sold in the EU).

Materials

Pump

Components
Part Nr.
4SD, 4SDF
6SD, 6SDN
External jacket
14.02
Cr-Ni steel AISI 304
Stage casing (4SDF) 25.02 Cr-Ni steel AISI 304
Stage casing (4,6SD) 25.02
Polycarbonate
(Lexan 141 R)
GFN2V*
Diffuser
26.00
(NORYL)
Impeller
28.00 GFN2V* (NORYL)* for 4SDF
Wear ring
Cr-Ni steel AISI 304
Shaft
64.00
Cr steel AISI 430 F
Delivery casing
12.01
Cr-Ni steel
Bronze
Suction lantern
32.02
AISI 304
G-Cu Sn 10 EN 1982
Bearing bush
Strainer
Screws
* Trademark of General Electric
Components

Motor

External frame
Shaft

12.03-12.30
15.50

Thermoplastic

Rubber

Cr-Ni steel AISI 430


Cr-Ni steel AISI 304

4CS

6CS-R

Cr-Ni steel AISI 304


Cr-Ni-Mo steel
AISI 316 (shaft end)

Cr steel AISI 431

Thrust bearing

Oil wetted ball type

Oscillation pads

Bearing bush

Oil wetted ball type

Graphite

361

Motor

4CS
6CS-R

Max.
Liquid
temperature
35 C
30 C
25 C

Cooling:
minimum
flow velocity
0,08 m/s
0,1 m/s
0,2 m/s
0,2 m/s
0,2 m/s

Max.
starts
per hour
20
15
15
15
13

Motor
P2
all types
411 kW
1315 kW
18,5 kW
2230 kW

Insulation class F for 4 motors, class E for 6 motors.


Motor suitable operation with frequency converter .
Protection IP 68.

Special features on request


- Other voltages.
- 60 Hz frequency.
- Other temperatures.
- Encapsulated motor FK series (for characteristic see pag. 404).

Designation

of the well in inches


Series
Single-phase motor (up to max. 2,2 kW)
Stage identification
Number of stages

SD M 31 / 26

42

SD

Submersible borehole pumps for 4 and 6 wells

Coverage chart n 2900 rpm


3
2

4
3

5
4

U.S. g.p.m.
5

10

Imp. g.p.m.

30

20
20

10

40
30

50
40

100
50

200
100

300
200

500

1500

400

SD, SDF, SDN

300

1000

200

ft
6SDN 12

500

4SD 31

100

6SD 20

4SDF
16

400
300

4SDF
22

4SDF
36

6SDN
16

6SDN
21

200

4SDF 4SDF
46
54

50
40

4SD 10

6
SD
18

4SD 15

30

6
SD
19

100

20
50
40
10

30
20

5
0.5
10

m3/h 1
l/min

2
20

30

40

3
50

5
100

10
150
200

20
300
400

30
500

40

50

60 70
1000
72.1002/N

362

4SD, 4SDF

Submersible borehole pumps for 4

Performance n 2900 rpm


400 V

3~

(380-415)

50 Hz

1~

4SDM 31/11EC
4SDM 31/17EC
4SDM 31/26EC
4SDM 31/35EC
4SDM 31/54EC
4SDFM 16/6EC
4SDFM 16/9EC
4SDFM 16/14EC
4SDFM 16/19EC
4SDFM 16/27EC
4SDFM 16/37EC
4SDFM 16/55EC
4SDFM 22/4EC
4SDFM 22/7EC
4SDFM 22/10EC
4SDFM 22/14EC
4SDFM 22/21EC
4SDFM 22/28EC
4SDFM 22/42EC

3,2
3,2
4
5,6
8,4
3,2
3,2
4
5,6
8,4
11,2
14,7
3,2
3,2
4
5,6
8,4
11,2
14,7

450 Vc
F
16
16
25
35
40
16
16
25
35
40
60
70
16
16
25
35
40
60
70

4SDFM 36/4EC
4SDFM 36/6EC
4SDFM 36/8EC
4SDFM 36/11EC
4SDFM 36/17EC
4SDFM 36/23EC
4SDFM 36/29EC
4SDFM 36/34EC

3,2
3,2
4
5,6
8,4
11,2
14,7
14,7

16
16
25
35
40
60
70
70

0,62
0,7
0,89
1,22
1,82
2,33
3,27
3,27

4SDFM 46/5EC
4SDFM 46/7EC
4SDFM 46/10EC
4SDFM 46/15EC
4SDFM 46/21EC
4SDFM 46/31EC

3,2
4
5,6
8,4
11,2
14,7

16
25
35
40
60
70

0,7
0,89
1,22
1,82
2,33
3,27

A
4SD 31/11EC
4SD 31/17EC
4SD 31/26EC
4SD 31/35EC
4SD 31/54EC
4SDF 16/6EC
4SDF 16/9EC
4SDF 16/14EC
4SDF 16/19EC
4SDF 16/27EC
4SDF 16/37EC
4SDF 16/55EC
4SDF 22/4EC
4SDF 22/7EC
4SDF 22/10EC
4SDF 22/14EC
4SDF 22/21EC
4SDF 22/28EC
4SDF 22/42EC
4SDF 22/57EC
4SDF 36/4EC
4SDF 36/6EC
4SDF 36/8EC
4SDF 36/11EC
4SDF 36/17EC
4SDF 36/23EC
4SDF 36/29EC
4SDF 36/34EC
4SDF 36/45EC
4SDF 36/58EC
4SDF 46/5EC
4SDF 46/7EC
4SDF 46/10EC
4SDF 46/15EC
4SDF 46/21EC
4SDF 46/31EC
4SDF 46/42EC
4SDF 46/55EC

1,2
1,2
1,5
2
2,9
1,2
1,2
1,5
2
2,9
4,2
5,5
1,2
1,2
1,5
2
2,9
4,2
5,5
7,4
1,2
1,2
1,5
2
2,9
4,2
5,5
5,5
7,4
9,4
1,2
1,5
2
2,9
4,2
5,5
7,4
9,4

230V Capacitor P1
A

400 V

3~

(380-415)

50 Hz

1~

4SDF 54/5EC
1,5
4SDF 54/7EC
2
4SDF 54/10EC 2,9
4SDF 54/14EC 4,2
4SDF 54/21EC 5,5
4SDF 54/29EC 7,4
4SDF 54/38EC 9,4
4SDF 54/53EC 13
2
4SD 10/4EC
2,9
4SD 10/6EC
4,2
4SD 10/8EC
5,5
4SD 10/12EC
7,4
4SD 10/17EC
9,4
4SD 10/20EC
9,4
4SD 10/22EC
9,4
4SD 10/24EC
13
4SD 10/27EC
13
4SD 10/30EC
4,2
4SD 15/6EC
5,5
4SD 15/9EC
7,4
4SD 15/12EC
9,4
4SD 15/15EC
9,4
4SD 15/17EC
13
4SD 15/23EC
18,8
4SD 15/30E

P1 Max. power input

kW

HP

0,62
0,7
0,89
1,22
1,82
0,62
0,7
0,89
1,22
1,82
2,33
3,27
0,62
0,7
0,89
1,22
1,82
2,33
3,27

0,37
0,37
0,55
0,75
1,1
0,37
0,37
0,55
0,75
1,1
1,5
2,2
0,37
0,37
0,55
0,75
1,1
1,5
2,2
3
0,37
0,37
0,55
0,75
1,1
1,5
2,2
2,2
3
4
0,37
0,55
0,75
1,1
1,5
2,2
3
4

0,5
0,5
0,75
1
1,5
0,5
0,5
0,75
1
1,5
2
3
0,5
0,5
0,75
1
1,5
2
3
4
0,5
0,5
0,75
1
1,5
2
3
3
4
5,5
0,5
0,75
1
1,5
2
3
4
5,5

4SDFM 54/5EC
4SDFM 54/7EC
4SDFM 54/10EC
4SDFM 54/14EC
4SDFM 54/21EC

4
5,6
8,4
11,2
14,7

4SDM 10/4EC
4SDM 10/6EC
4SDM 10/8EC
4SDM 10/12EC

5,6
8,4
11,2
14,7

35
40
60
70

4SDM 15/6EC
4SDM 15/9EC

kW

230V Capacitor P1
450 Vc
F
25
35
40
60
70

11,2
14,7

P2 Rated motor power output

60
70

1)

P2

kW

HP

0,89 0,55 0,75


1,22 0,75 1
1,82 1,1 1,5
2,33 1,5
2
3,27 2,2
3
3
4
4
5,5
5,5 7,5
1,22 0,75 1
1,82 1,1 1,5
2,33 1,5
2
3,27 2,2
3
3
4
4
5,5
4
5,5
4
5,5
5,5 7,5
5,5 7,5
2,33 1,5
2
3,27 2,2
3
3
4
4
5,5
4
5,5
5,5 7,5
7,5 101)

Motor Franklin

2900 1/min

0,6

0,9

1,2

1,5

1,8

l/min

2,1

2,4

2,7

3,3

3,6

4,2

4,8

5,4

2,5

10

15

20

25

30

35

40

45

50

55

60

70

80

90

100

45,6
67,7
104
131
203

43,8
64,5
98,9
124
193
35,1
52,7
82
111
158
217
322
25,8
45,1
64,4
90,2
135
180
271
367

39,3
57,3
87,9
109
170
33,6
50,4
78,5
106
151
207
308
25,2
44
62,9
88,1
132
176
264
359
22,8
34,2
45,6
62,7
96,9
131
165
194
256
331

33,8
49,4
75,2
92,6
144
31,5
47,2
73,4
100
142
194
288
24,3
42,5
60,7
84,9
127
170
255
346
22,3
33,5
44,7
61,4
95
128
162
190
251
324
27,8
38,9
55,5
83,3
117
172
233
305

28
40,9
61,2
73,8
116
28,6
42,9
66,8
90,6
129
176
262
23,1
40,4
57,7
80,8
121
162
242
329
21,8
32,7
43,6
59,9
92,6
125
158
185
245
316
27,1
37,9
54,2
81,3
114
168
228
298

20,9
31
45,7
53,1
86
25,1
37,6
58,5
79,5
113
155
230
21,6
37,8
54
75,6
113
151
227
308
21,3
31,9
42,5
58,4
90,3
122
154
180
239
308
26,4
36,9
52,7
79,1
111
163
221
290

14
20,2
28,1
30,8
52,9
21
31,4
48,9
66,4
94,3
129
192
19,8
34,7
49,6
69,5
104
139
208
283
20,5
30,7
40,9
56,3
87
118
148
174
230
297
25,6
35,9
51,3
76,9
108
159
215
282

16,3
24,4
38
51,5
73,2
100
149
17,8
31,2
44,5
62,3
93,5
125
187
254
19,7
29,6
39,4
54,2
83,8
113
143
168
222
286
25
35
50
75
105
155
210
275

11,1
16,6
25,8
35,1
49,8
68,3
102
15,5
27,1
38,8
54,3
81,4
109
163
221
18,8
28,3
37,7
51,8
80,1
108
137
160
212
273
23,9
33,5
47,8
71,7
100
148
201
263

13
22,8
32,5
45,5
68,3
91,1
137
185
17,9
26,9
35,9
49,3
76,2
103
130
152
202
260
22,9
32
45,8
68,7
96,2
142
192
252

10,3
18
25,8
36,1
54,1
72,2
108
147
16,8
25,2
33,6
46,2
71,4
96,6
122
143
189
244
21,9
30,6
43,7
65,6
91,9
136
184
241

7,4
13
18,5
25,9
38,9
51,9
77,8
106
15,6
23,4
31,2
42,9
66,2
89,6
113
132
175
226
20,7
29
41,5
62,2
87,1
129
174
228

14,1
21,2
28,2
38,8
60
81,2
102
120
159
205
19,6
27,4
39,1
58,7
82,2
121
164
215

10,7
16
21,3
29,4
45,4
61,4
77,4
90,7
120
155
17
23,8
34
51
71,4
105
143
187

6,6
9,9
13,2
18,1
28
37,8
47,7
55,9
74
95,4
14,2
19,9
28,4
42,6
59,6
88
119
156

11,1
15,5
22,2
33,3
46,6
68,8
93,2
122

7,6
10,7
15,3
22,9
32,1
47,4
64,2
84,1

8,4

9,6 10,8 12

15

18

21

H
m

P2
kW

m3/h 0,15 0,3

2900 1/min

m /h

1,2

1,5

1,8

2,4

3,6

4,8

l/min

20

25

30

40

50

60

80

29,1
40,7
64
87,3
128
175
233
320

28,5
39,8
62,6
85,4
125
171
228
313
27
40
54
81
114
134
148
162
182
202

28
39,2
61,6
84,1
123
168
224
308
26,5
40
53,5
80
113
133
147
160
180
200

26,8
37,6
59,1
80,5
118
161
215
295
26
39
53
79
112
132
145
158
178
198

25,6
35,8
56,3
76,7
113
153
205
281
26
39
52
78
111
130
143
156
176
195
33
50
67
84
95
129
168

24,2
33,8
53,2
72,5
106
145
193
266
25
38
51
76
108
127
139
152
171
190
33
49
66
83
94
127
166

20,9
29,3
46
62,7
92
125
167
230
24
36
48
72
102
120
132
144
162
180
32
48
64
81
92
124
162

H
m

16,8
23,5
36,9
50,3
73,7
101
134
184
23
34
45
67
95
112
123
134
151
168
31
47
62
78
88
120
156

* Only for single-phase motor 230 V - 50 Hz (on request)


363

7,2

8,1

100 120 135 140 160 180 200 250 300 350
11,6
16,3
25,6
34,8
51,1
69,7
92,9
128
20
31
41
61
87
102
112
122
138
153
30
45
59
74
84
114
149

6,6
9,3
14,6
19,9
29,2
39,9
53,1
73,1
18,5
28
37
56
79
93
102
112
126
140
29
43
57
71
81
109
142

18
27
36
54
76
90
99
108
122
135
29
43
57
71
81
109
142

15 12
8
23 18 12
30 25 16
46 37 25
65 52 35
76 61 41
84 67 45
91 74 50
103 83 56
114 92 62
28 26 24
42 38 36
56 51 48
69 64 59
79 72 67
107 98 91
140 128 119

42

19
29
38
48
54
74
97

14
21
28
35
40
54
70

8
13
17
21
24
32
42

Tolerances according to UNI EN ISO 9906:2012

4SD 31

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0
250

2
1

U.S. g.p.m.
2

Imp. g.p.m.

8
6

7
800
G 1 1/4

4SD 31
700
54

200

600

H
ft

150

35

400

fM

26

100

300
17
200
50

11
100

0
0

m3/h
l/min

0.4

0.8
10

0.1

l/s

1.2
20

0.2

1.6

3.93.063.2N

30

0.3

0.4

96

0.5

50

0.03

40

98

kW/st

%
0.02

kW
20
10
0

3~

0.4

m /h

400 V
(380-415)
50 Hz
A

0.8

1~

1.2

1.6

*
P2
230VCapacitor P1
450 Vc
F kW kW HP
A
3,2 16 0,62 0,37 0,5

l/min

0.01

n
2900rpm
1/min
n 2900

Q
m3/h

72.1007

4SD

0,15 0,3

0,6

0,9

1,2

1,5

1,8

2,5

10

15

20

25

30

f
mm

fM
mm

47 45,6 43,8 39,3 33,8 28 20,9 14

402

729
847

4SDM
kg

fM
mm

kg

12

729

11,6

13

847

12,6

4SD 31/11EC

1,2

4SDM 31/11EC

4SD 31/17EC

1.2

4SDM 31/17EC

3,2

16

0,7 0,37 0,5

70,5 67,7 64,5 57,3 49,4 40,9 31 20,2

520

4SD 31/26EC

1.5

4SDM 31/26EC

25

0,89 0,55 0,75

107 104 98,9 87,9 75,2 61,2 45,7 28,1

698 1045 13,5 1060 15,7

4SD 31/35EC

4SDM 31/35EC

5,6

35

1,22 0,75

4SD 31/54EC

2.9

4SDM 31/54EC

8,4

40

1,82 1,1

1,5

P1 Max. power input

P2 Rated motor power output

H m

138 131 124 109 92,6 73,8 53,1 30,8

875 1237 15,8 1277 18,3

211 203 193 170 144 116

1295 1697

* Only for single-phase motor 230 V - 50 Hz (on request)


364

86 52,9

20

1742 23,3

Tolerances according to UNI EN ISO 9906:2012

4SDF 16

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


1 U.S. g.p.m 3

0
0

Imp. g.p.m

8
6

10

11

340

1100

G 1 1/4

55

4SDF 16

300

1000

900

ft
800

m
37

700
f

200
600
27

fM

500

400
19
100
300

14

200

9
6

100

3.93.063.2N

0
0
0

0,5

m3/h
Q
l/min

1
10

l/s 0,1

15

1,5
25

20

0,2

0,3

0,4

2
30

2,5
35

0,5

96

40

0,6

45
0,7
72.1172

50

40

0,07

98

kW/st

30

0,05

20

0,04
kW/st

0,03

0,02

Q m3/h 0,5

1,5

2,5

42
3~

400 V
(380-415)
50 Hz
A

1~

*
P2
230VCapacitor P1
450 Vc
F kW kW HP
A
3,2 16 0,62 0,37 0,5

n 2900
1/min
n 2900
rpm

Q
m3/h
l/min

0,3

0,6

0,9

1,2

1,5

10

15

20

25

4SDF

1,8
30

2,1

2,4

35

40

f
mm

fM
mm

16,3 11,1

305

632

4SDFM

kg

fM
mm

kg

11

632

11,1

4SDF 16/6EC

1,2

4SDFM 16/6EC

4SDF 16/9EC

1,2

4SDFM 16/9EC

3,2

16

0,7 0,37 0,5

54,2 52,7 50,4 47,2 42,9 37,6 31,4 24,4 16,6

365

692

11,5

692

11,6

4SDF 16/14EC

1,5

4SDFM 16/14EC

25

0,89 0,55 0,75

84,3

82

25,8

465

812

13,4 827

12,7

4SDF 16/19EC

4SDFM 16/19EC

5,6

35

1,22 0,75

114

111 106 100 90,6 79,5 66,4 51,5 35,1

565

927

15,6 967

14,8

4SDF 16/27EC

2,9

4SDFM 16/27EC

8,4

40

1,82 1,1

1,5

163 158 151 142 129 113 94,3 73,2 49,8

4SDF 16/37EC

4,2

4SDFM 16/37EC 11,2

60

2,33 1,5

223 217 207 194 176 155 129 100 68,3

915 1362 21,7 1382 22,8

4SDF 16/55EC

5,5

4SDFM 16/55EC 14,7

70

3,27 2,2

331 322 308 288 262 230 192 149 102

1325 1727 24,6 1842 30,6

P1 Max. power input

P2 Rated motor power output

36,1 35,1 33,6 31,5 28,6 25,1

H m

78,5 73,4 66,8 58,5 48,9

* Only for single-phase motor 230 V - 50 Hz (on request)


365

21

38

725 1127

18

1172 17,4

Tolerances according to UNI EN ISO 9906:2012

4SDF 22

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0 U.S. g.p.m

0 Imp. g.p.m

9
7

10
8

11

12

10

13

14

11

15

12

380
G 1 1/4

1200

57

4SDF 22
1100
1000

300

H
ft
900

42

H
m

800
f

700
200
600

28

fM

500
21
400
100

14

300

10

200

7
4

100

3.93.063.2N

0
0
0

m3/h
Q
l/min

10

20

0,2

l/s

0,3

30
0,4

3
50

40

0,5

0,6

0,7

3,6
60

0,8

0,9

96

1,0
72.1173

60

50

98

kW/st

40

0,06

30

0,05

kW/st

0,04

10
0

0,03

Q m3/h

3~

400 V
(380-415)
50 Hz
A

1~

*
P2
230V Capacitor P1
450 Vc
F kW kW HP
A
3,2 16 0,62 0,37 0,5

3,6

2900rpm
1/min
n n 2900

Q
m3/h
l/min

4SDF

0,3

0,6

0,9

1,2

1,5

1,8

2,4

3,3

10

15

20

25

30

40

50

55

f
mm

fM
mm

26,1 25,8 25,2 24,3 23,1 21,6 19,8 15,5 10,3 7,4

265

592

4SDF 22/4EC

1,2

4SDFM 22/4EC

4SDF 22/7EC

1,2

4SDFM 22/7EC

3,2

16

0,7 0,37 0,5

45,6 45,1

4SDF 22/10EC

1,5

4SDFM 22/10EC

25

0,89 0,55 0,75

65,2 64,4 62,9 60,7 57,7

44

42,5 40,4 37,8 34,7 27,1


54

18

13

kg

4SDFM
fM
mm

10,6 592

kg
10,6

325

652

11,2

652

11,1

49,6 38,8 25,8 18,5

385

732

10,7 747

13,4

827

12,2 867

15,4

4SDF 22/14EC

4SDFM 22/14EC 5,6

35

1,22 0,75

91,2 90,2 88,1 84,9 80,8 75,6 69,5 54,3 36,1 25,9

465

4SDF 22/21EC

2,9

4SDFM 22/21EC 8,4

40

1,82 1,1

1,5

137 135 132 127 121 113 104 81,4 54,1 38,9

605 1007 14,7 1052 18,5

4SDF 22/28EC

4,2

4SDFM 22/28EC 11,2

60

2,33 1,5

182 180 176 170 162 151 139 109 72,2 51,9

745 1192 17,4 1212 20,9

4SDF 22/42EC

5,5

4SDFM 22/42EC 14,7

70

3,27 2,2

274 271 264 255 242 227 208 163 108 77,8

1015 1417 28,4 1532 25,8

4SDF 22/57EC

7,4

371 367 359 346 329 308 283 221 147 106

1365 1846

P1 Max. power input

P2 Rated motor power output

H m

* Only for single-phase motor 230 V - 50 Hz (on request)


366

33

Tolerances according to UNI EN ISO 9906:2012

4SDF 36

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


2 U.S. g.p.m 6

0
0

Imp. g.p.m

10

12

14

10

16

12

18

20

14

22

16

18

340

1100

58

4SDF 36

300

G 1 1/4

1000

900

H
ft

45

H
m

800

700
f

200

34
600
29
fM

500
23
400
100

17

300

11

200

8
6
4

100

3.93.063.2N

0
0
0

m3/h
Q
l/min

l/s

2
20

0,2

30

3
50

40

0,4

0,6

4
60

0,8

5
70

1,0

80

1,2

5,4
90

96

1,4
72.1174

60

50

kW/st

40

0,07

kW/st

30

0,06

0,05

10

0,04

Q m3/h

3~

98

400 V
(380-415)
50 Hz
A

1~

*
P2
230VCapacitor P1
450 Vc
F kW kW HP
A
3,2 16 0,62 0,37 0,5

5,4

n
n 2900
2900rpm
1/min

4SDF

m3/h

0,6

1,2

1,8

2,4

3,6

4,2

4,8

l/min

10

20

30

40

50

60

70

80

f
mm

fM
mm

23,4 22,8 21,8 20,5 18,8 16,8 14,1 10,7 6,6

306

633

kg

4SDFM
fM
mm

kg

4SDF 36/4EC

1,2

4SDFM 36/4EC

4SDF 36/6EC

1,2

4SDFM 36/6EC

3,2

16

0,7 0,37 0,5

35,1 34,2 32,7 30,7 28,3 25,2 21,2

9,9

366

693

11,1

4SDF 36/8EC

1,5

4SDFM 36/8EC

25

0,89 0,55 0,75

46,8 45,6 43,6 40,9 37,7 33,6 28,2 21,3 13,2

426

773

10,6 788

13,3

4SDF 36/11EC

4SDFM 36/11EC

5,6

35

1,22 0,75

64,3 62,7 59,9 56,3 51,8 46,2 38,8 29,4 18,1

517

879

12,2 919

15,4

4SDF 36/17EC

2,9

4SDFM 36/17EC

8,4

40

1,82 1,1

1,5

99,4 96,9 92,6

699 1101 14,7 1146 18,5

4SDF 36/23EC

4,2

4SDFM 36/23EC 11,2

60

2,33 1,5

134 131 125 118 108 96,6 81,2 61,4 37,8

880 1327 17,5 1347

4SDF 36/29EC

5,5

4SDFM 36/29EC 14,7

70

3,27 2,2

170 165 158 148 137 122 102 77,4 47,7

1063 1465 27,3 1580 24,7

4SDF 36/34EC

5,5

4SDFM 36/34EC 14,7

70

3,27 2,2

199 194 185 174 160 143 120 90,7 55,9

1213 1694 28,7 1730 26,1

4SDF 36/45EC

7,4

263 256 245 230 212 189 159 120

1590 2136 28,4

4SDF 36/58EC

9,4

5,5

P1 Max. power input

P2 Rated motor power output

H m

87

80,1 71,4

60

16

45,4

28

74

339 331 316 297 273 244 205 155 95,4

* Only for single-phase motor 230 V - 50 Hz (on request)


367

10,7 633
693

1981 2627 34,3

Tolerances according to UNI EN ISO 9906:2012

10,6
11

21

42

4SDF 46

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0 U.S. g.p.m

0 Imp. g.p.m 4

10

12

10

14

16

12

18

14

20
16

22

24

18

26

20

28

22

340

1100

4SDF 46

55

300

G 1 1/4

1000

900

H
m

ft

800
42
700
f

200
600
31

fM

500

21

400

15

300

10

200

7
5

100

100

3.93.063.2N

0
0
0

m /h
l/min
3

2
20

30

3
50

40

0,5

l/s

4
60

5
70

80

6
100

90

1,0

96

1,5
72.1175

60

50

98

kW/st

40

0,08

30

0,07
kW/st

%
10
0

0,05

Q m3/h

3~

0,06

400 V
(380-415)
50 Hz
A

1~

*
P2
230V Capacitor P1
450 Vc
F kW kW HP
A
3,2 16
0,7 0,37 0,5

2900
29001/min
nn
rpm

Q
m3/h
l/min

0,9

1,2

1,8

2,4

3,6

15

20

30

40

50

60

4SDF

4,2
70

4,8

80

4SDFM

100

f
mm

fM
mm

14,2 7,6

315

642

10,9 642

10,8

kg

fM
mm

kg

4SDF 46/5EC

1,2

4SDFM 46/5EC

4SDF 46/7EC

1,5

4SDFM 46/7EC

25

0,89 0,55 0,75

41,2 38,9 37,9 35,9 33,5 30,6 27,4 23,8 19,9 10,7

370

717

10,4 732

13,1

4SDF 46/10EC

4SDFM 46/10EC 5,6

35

1,22 0,75

58,9 55,5 54,2 51,3 47,8 43,7 39,1

34

28,4 15,3

450

812

11,8 852

15

4SDF 46/15EC

2,9

4SDFM 46/15EC 8,4

40

1,82 1,1

1,5

88,3 83,3 81,3 76,9 71,7 65,6 58,7

51

42,6 22,9

585

987

4SDF 46/21EC

4,2

4SDFM 46/21EC 11,2

60

2,33 1,5

124 117 114 108 100 91,9 82,2 71,4 59,6 32,1

740 1187 16,7 1207 20,2

4SDF 46/31EC

5,5

4SDFM 46/31EC 14,7

70

3,27 2,2

183 172 168 159 148 136 121 105

1005 1407 27,2 1522 24,6

4SDF 46/42EC

7,4

247 233 228 215 201 184 164 143 119 64,2

1340 1821 31,5

4SDF 46/55EC

9,4

5,5

324 305 298 282 263 241 215 187 156 84,1

1685 2231 38,6

P1 Max. power input

P2 Rated motor power output

29,4 27,8 27,1 25,6 23,9 21,9 19,6

H m

* Only for single-phase motor 230 V - 50 Hz (on request)


368

17

88

47,4

14

1032 17,8

Tolerances according to UNI EN ISO 9906:2012

4SDF 54

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0 U.S. g.p.m

12

0 Imp. g.p.m

16

20

12

24

16

28

20

32

24

36
28

340

1100
53

4SDF 54

300

G 1 1/4

1000

900

H
ft

H
m

800
38
700
f

200
600

29

fM

500
21
400
100
300

14
10

200
7
5

100

2
40

60

0,5

l/s

5
80

1,0

7
120

6
100
1,5

96

140

2,0
72.1176

60

50

98

kW/st

40

0,12

30

0,10
kW/st

%
10

3.93.063.2N

0
0
m3/h 1
Q
l/min 20
0

0,08
0,06

0 Q m3/h 1

42
3~

400 V
(380-415)
50 Hz
A

1~

*
P2
230V Capacitor P1
450 Vc
F kW kW HP
A
25 0,89 0,55 0,75
4

n 2900
1/min
n 2900
rpm

Q
m3/h
l/min

1,2

20

1,8

4SDF

2,4

3,6

4,8

40

50

60

80

7,2

8,1

100 120 135

f
mm

fM
mm

26,8 25,6 24,2 20,9 16,8 11,6 6,6

340

687

43,1 40,7 39,2 37,6 35,8 33,8 29,3 23,5 16,3 9,3

400

67,7

490

30

kg

kg

9,9

702

12,6

762

11,2

802

14,4

892

13

937

16,8

4SDF 54/5EC

1,5

4SDFM 54/5EC

4SDF 54/7EC

4SDFM 54/7EC

5,6

35

1,22 0,75

4SDF 54/10EC

2,9

4SDFM 54/10EC 8,4

40

1,82 1,1

1,5

4SDF 54/14EC

4,2

4SDFM 54/14EC 11,2

60

2,33 1,5

4SDF 54/21EC

5,5

4SDFM 54/21EC 14,7

70

3,27 2,2

135 128 123 118 113 106

4SDF 54/29EC

7,4

185 175 168 161 153 145 125 101 69,7 39,9

1060 1541 28,8

4SDF 54/38EC

9,4

5,5

246 233 224 215 205 193 167 134 92,9 53,1

1380 1926 35,6

4SDF 54/53EC

13

5,5

7,5

338 320 308 295 281 266 230 184 128 73,1

1830 2476 41,8

P1 Max. power input

P2 Rated motor power output

30,8 29,1

H m

64

28

61,6 59,1 56,3 53,2

46

36,9 25,6 14,6

92,3 87,3 84,1 80,5 76,7 72,5 62,7 50,3 34,8 19,9

* Only for single-phase motor 230 V - 50 Hz (on request)


369

92

73,7 51,1 29,2

4SDFM
fM
mm

610 1057 15,4 1077 18,9


820 1222 25,4 1337 22,8

Tolerances according to UNI EN ISO 9906:2012

4SD 10

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

10

U.S. g.p.m.

20
10

20

40

50

Imp. g.p.m.

60

40

50

220
700
30

200

4SD 10
Pumps for specific applications with
high percentage of solids and sand

27

600
H
ft

24
150

22

20

G2

500

400
17
fM

100
300
12

200

8
50
6

100

0
0

m3/h
l/min

l/s

6
100

50
1

10

12
200

150
2

60

14

3.93.063.2N

96

0.22

98

0.18

40
kW

kW/st

20

0.14

3~

m /h
400 V
(380-415)
50 Hz
A

1~

10

12

Q
*
P2
230V Capacitor P1
m3/h 1,5
450 Vc
F kW kW HP l/min 25
A
5,6 35 1,22 0,75 1
27

72.1013

14

0.10

rpm
nn 2900
2900 1/min
2,4

3,6

4,8

40

50

60

80

26

26

25

24

7,2

4SD
8,4

9,6 10,8

12

4SDM

100 120 140 160 180 200

f
mm

fM
mm

23

20

18

15

12

409

771

11,6 811

14,1

917

13,4 962

16,7

kg

fM
mm

kg

4SD 10/4EC

4SDM 10/4EC

4SD 10/6EC

2.9

4SDM 10/6EC

8,4

40

1,82 1,1

1,5

40

39

39

38

36

34

31

27

23

18

12

515

4SD 10/8EC

4,2

4SDM 10/8EC

11,2

60

2,33 1,5

54

53

52

51

48

45

41

36

30

25

16

621 1068 15,7 1088 18,6

4SD 10/12EC

5,5

4SDM 10/12EC 14,7

70

3,27 2,2

81

79

78

76

72

67

61

54

46

37

25

833 1235 25,9 1350 22,7

4SD 10/17EC

7,4

108 102

95

87

76

65

52

35

1098 1579

28

4SD 10/20EC

9,4

5,5

134 132 130 127 120 112 102

90

76

61

41

1312 1858

36

4SD 10/22EC

9,4

5,5

148 145 143 139 132 123 112

99

84

67

45

1418 1964 36,8

4SD 10/24EC

9,4

5,5

162 158 156 152 144 134 122 108

91

74

50

1524 2070 37,6

4SD 10/27EC

13

5,5

7,5

182 178 176 171 162 151 138 122 103

83

56

1683 2329 41,1

4SD 10/30EC

13

5,5

7,5

202 198 195 190 180 168 153 135 114

92

62

1842 2488 42,1

P1 Max. power input

P2 Rated motor power output

H m

114 112 111

* Only for single-phase motor 230 V - 50 Hz (on request)


370

Tolerances according to UNI EN ISO 9906:2012

4SD 15

Submersible borehole pumps for 4 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0
180

U.S. g.p.m.

20

60

80

Imp. g.p.m.

20

100

60

80
G2

4SD 15

30

Pumps for specific applications with


high percentage of solids and sand

150

500

23

400
H
ft

100
17

300

15

fM

12
200
9

50

0
0

m3/h
l/min

100

16

12

100

200

24

300

l/s

20

3.93.063.2N

96

400

60

0.26

98

0.24
40
%

kW/st

kW

0.20

20

0.18
0.16

m /h
400 V
(380-415)
50 Hz
A

12

16

20

4SD 15/6EC

4,2

4SD 15/9EC

5,5

4SDM 15/9EC 14,7

1~

70

3,27 2,2

4SD 15/12EC 7,4

4SD 15/15EC 9,4

4SD 15/17EC 9,4

13

4SD 15/23EC
4SD 15/30E

P2 Rated motor power output

0.14

42

7,2

8,4

4SD

9,6 10,8 12

15

18

21

4SDM

3,6

4,8

60

80

100 120 140 160 180 200 250 300 350

f
mm

755 1202 15,6 1222 18,5

fM
mm

kg

33

32

31

30

29

28

26

24

19

14

50

49

48

47

45

43

42

38

36

29

21

13

988 1390

67

66

64

62

59

57

56

51

48

38

28

17

1299 1780 34,3

5,5 H m 84
95
5,5

83

81

78

74

71

69

64

59

48

35

21

1601 2147 40,6

94

92

88

84

81

79

72

67

54

40

24

1756 2302 41,4

129 127 124 120 114 109 107

98

91

74

54

32

2291 2937 49,4

168 166 162 156 149 142 140 128 119

97

70

42

2836 3610

7,5

7,51) 101)

18,8

P1 Max. power input


1)

5,5

24

2900
rpm
1/min
nn2900

P2
230V Capacitor P1
m3/h 3
450 Vc
F kW kW HP l/min 50
A
60
11,2
2,33 1,5 2
4SDM 15/6EC
33

3~

72.1014

* Only for single-phase motor 230 V - 50 Hz (on request)

Franklin motor

371

fM
mm

kg

33 1505 30,2

62

Tolerances according to UNI EN ISO 9906:2012

6SDN 12

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


20 U.S. g.p.m. 40

0
400

60

Imp. g.p.m.

20

80

40

60
DN

6SDN 12
H

1200

Pumps for specific applications with


high percentage of solids and sand

34

1000

300

29

H
ft
24

200

800

19

600

14
400
10

100

200
3.93.110.2

0
0

6
100

m 3/h
l/min
l/s 1

12
200
2

18
300

20

14

15

5
80

0.5

0.4

60
%

kW/st

40

kW/st
0.3

20
0.2
0

m 3/h

12

18

20

3~

P2
m /h
3

kW
6SDN 12/10
6SDN 12/14
6SDN 12/19
6SDN 12/24
6SDN 12/29
6SDN 12/34

72.1150

HP

4
5,5
5,5
7,5
7,5
10
9,2
12,5
11
15
13 (15) 17,5 (20)

P2 Rated motor power output

l/min

H
m

14

16

18

33,3 66,6

100 133,3 166,6 200

233

266

300

102
142
193
244
294
345

89,5
125
170
215
260
304

80,5 73,5 64
113 103 89,5
153 140 122
193 176 154
233 213 186
274 250 218

52
73
99
125
151
177

37
52
70,5
89
107
126

(...) FK motor rated power output

85
119
162
204
247
289

10

2900 rpm
12

95
133
181
231
276
323

H Total head in m

372

DN

f
mm

715
870
1060
G3
ISO 228 1320
1510
1705

Tolerances according to UNI EN ISO 9906:2012

kg
15,5
17,5
20
23
25,7
28,5

6SDN 16

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0
400

20

U.S. g.p.m.

40
20

80

100

Imp. g.p.m.

40

80
DN

6SDN 16
H

1200

Pumps for specific applications with


high percentage of solids and sand

33

1000

300

27

ft
800

23
20

200

600

17

13
400
10

100

7
200
3.93.110.2

0
0

m 3/h 5
100
l/min
l/s

15

10
200
2

25
400

20
300

14

15

80
0.6

0.5

60
%

kW/st

40

kW/st
0.4

20
0.3
0

m 3/h

10

15

20

72.1126

25

42
Q

3~

6SDN 16/7
6SDN 16/10
6SDN 16/13
6SDN 16/17
6SDN 16/20
6SDN 16/23
6SDN 16/27
6SDN 16/33

P2

kW

HP

4
5,5
7,5
9,2
11
13 (15)
15
18,5

5,5
7,5
10
12,5
15
17,5 (20)
20
25

P2 Rated motor power output

2900 rpm

m /h

12

15

18

21

l/min

50

100

150

200

250

300

350 416,6

75
107
139
182
215
247
290
354

71
101
132
172
202
233
273
334

67
96
124
163
192
220
259
316

63,5
91
118
155
182
209
245
300

59
84
110
143
168
194
227
278

50
38 18,5
71,5 54,5 26
93 70,5 34
122 92,5 44,5
143 109 52,5
165 125
60
193 147
71
236 179 86,5

H
m

(...) FK motor rated power output

H Total head in m

373

25

DN

f
mm

600
715
830
G3
ISO 228 985
1100
1285
1435
1665
Tolerances according to UNI EN ISO 9906:2012

kg
14
15,5
17
19
20,5
22,5
24,6
28

6SDN 21

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

U.S. g.p.m.

50

50

100

150

Imp. g.p.m.

100

140

340
DN

300

6SDN 21

28

1000

Pumps for specific applications with


high percentage of solids and sand

23

800

H
ft

19

200

600
16

14

400

11
9

100

7
200

3.93.110.2

0
0

l/s

20

10

m 3/h
l/min

200

400

40

30

14

15

600

10
80

1.0

70

kW/st
0.8

50

kW/st

40
0.6

30
20

0.4

m 3/h

10

30

40

72.1142

3~

6SDN 21/5
6SDN 21/7
6SDN 21/9
6SDN 21/11
6SDN 21/14
6SDN 21/16
6SDN 21/19
6SDN 21/23
6SDN 21/28

20

P2

kW

HP

4
5,5
7,5
9,2
11
13 (15)
15
18,5
22

5,5
7,5
10
12,5
15
17,5 (20)
20
25
30

P2 Rated motor power output

10

2900 rpm

m3/h

12

15

18

21

24

27

30

33

l/min

83,3

150

200

250

300

350

400

450

500

550

H
m

54
51 48,5
75,5 71,5 68
97
92 87,5
119 112 107
151 143 136
173 163 155
205 194 185
249 235 224
303 286 272

(...) FK motor rated power output

46,5 45 41,5 36
29 21,5 11,5
65 62,5 58
50
41
30
16
83,5 80,5 74,5 64,5 53 38,5 21
102
99
91
79
64
47 25,5
130 125 116 100 81,5 60 32,5
149 143 132 114
93
69
37
176 170 157 136 111 81,5 44
213 206 190 164 134
99
53
260 251 231 200 163 120 64,5
H Total head in m

374

DN

f
mm

565
660
755
850
G3
ISO 228 990
1085
1225
1480
1710

Tolerances according to UNI EN ISO 9906:2012

kg
13,3
14,5
15,7
16,9
18,7
19,9
21,7
24,5
27,5

6SD 18

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

50 U.S. g.p.m.100

50 Imp. g.p.m.

150

200

100

150

250
800

6SD 18

DN

H
ft

m
16

700

CALPEDA

200

600
13

150

500

11

400

8
100

300
3.93.110.21

6
5
200

15

15

50
3
100

0
0

m 3/h 10
l/min
200
l/s

20
400
4

40

50

600
10

12

72.301

42
n

P2

kW

HP

4
5,5
5,5
7,5
7,5
10
9,2
12,5
9,2
12,5
11
15
13 (15) 17,5 (20)
15
20
18,5
25
22
30

P2 Rated motor power output

800

3~

6SD 18/3
6SD 18/4
6SD 18/5
6SD 18/6
6SD 18/7
6SD 18/8
6SD 18/9
6SD 18/11
6SD 18/13
6SD 18/16

30

2900 rpm

m3/h

12

18

24

30

36

42

45

l/min

100

200

300

400

500

600

700

750

mm

42
56
70
85
100
113
127
156
184
227

39
53
66
79
93
105
119
145
172
213

36
48
60
72
84
96
108
132
157
194

32
43
53
64
75
86
96
118
139
172

27
36
45
54
63
72
81
99
117
144

20
27
34
40
46
54
60
74
87
107

12
16
21
25
28
32
37
45
52
65

8
11
13
16
19
21
24
30
35
43

647
756
865
974
1083
G3
ISO 228 1192
1301
1519
1737
2064

H
m

(...) FK motor rated power output

H Total head in m

375

DN

Tolerances according to UNI EN ISO 9906:2012

kg
20,5
23
25
27
29,5
32
34,5
39,5
43
50,2

6SD 19

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

40

U.S. g.p.m.

80

40

160

200

Imp. g.p.m.

80

240

160

200

300
DN

6SD 19

ft
CALPEDA

250

17

800

200
13
f

600

11
150
9
400

8
7

100

3.93.110.21

6
5

4
50

15

15

200

3
2

20

m 3/h 10
200

Q l/min

l/s

400

600

60

50
800

10

15

72.302

P2

kW

HP

4
5,5
5,5
7,5
7,5
10
9,2
12,5
11
15
13 (15) 17,5 (20)
15
20
15
20
18,5
25
22
30
30
40

P2 Rated motor power output

1000

3~

6SD 19/2
6SD 19/3
6SD 19/4
6SD 19/5
6SD 19/6
6SD 19/7
6SD 19/8
6SD 19/9
6SD 19/11
6SD 19/13
6SD 19/17

40

30

2900 rpm

m3/h

12

18

24

30

36

42

48

54

l/min

100

200

300

400

500

600

700

800

900

mm

30
45
60
75
90
105
120
135
165
195
255

29
43
57
72
86
100
115
130
158
188
245

27
41
55
69
82
96
110
123
151
179
234

25
38
50
63
75
88
101
114
139
164
215

22
33
45
56
67
79
89
100
123
145
190

19
29
38
47
56
66
75
85
104
122
160

15
23
30
38
45
53
60
68
83
98
127

10
15
21
26
31
37
42
47
58
69
90

6
9
12
15
18
21
24
27
33
39
51

538
647
756
865
974
G3
1083
ISO 228
1192
1301
1519
1737
2173

H
m

(...) FK motor rated power output

H Total head in m

376

DN

Tolerances according to UNI EN ISO 9906:2012

kg
18
20,5
23
25
27
29,5
32
34,5
39,5
43
53

6SD 20

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

40

U.S. g.p.m.

80

40

160

200

Imp. g.p.m.

80

240

160

200

220
DN

700
200

6SD 20

13

H
ft
CALPEDA

600

10

500

150
9

400

7
100
6

300

5
3.93.110.21

200
1

50

0
0
0

l/s

40

30
400

600

60

50
800

10

15

kW

HP

5,5
7,5
7,5
10
9,2
12,5
11
15
13 (15) 17,5 (20)
15
20
18,5
25
18,5
25
22
30
30
40

72.299

42
n

P2

P2 Rated motor power output

15

1000

3~

6SD 20/2
6SD 20/3
6SD 20/4
6SD 20/5
6SD 20/6
6SD 20/7
6SD 20/8
6SD 20/9
6SD 20/10
6SD 20/13

100

20

m 3/h 10
200

Q l/min

15

2900 rpm

m3/h

12

18

24

30

36

42

48

54

57

l/min

200

300

400

500

600

700

800

900

950

mm

31
46
62
77
93
108
124
140
155
202

30
45
60
76
91
106
120
136
151
196

29
44
58
73
87
102
115
130
144
188

28
42
55
68
83
96
110
124
138
179

24
37
49
61
73
86
99
111
123
160

21
32
42
53
63
74
85
96
106
138

17
26
35
44
53
61
70
79
88
114

13
20
26
33
40
47
53
60
67
87

11
17
22
28
34
39
45
51
56
73

538
647
756
865
974
G3
ISO 228 1083
1192
1301
1410
1737

H
m

(...) FK motor rated power output

H Total head in m

377

DN

Tolerances according to UNI EN ISO 9906:2012

kg
18
20,5
23
25
27
29,5
32
34,5
36,2
44,4

09/2016

SDX

Submersible borehole pumps for 6 and 8 wells


Construction
Submersible borehole pumps for 6 wells (DN 150 mm) and 8
(DN 200 mm).
6,8SDX: with external jacket and stages in stainless steel AISI 304.
6,8SDXL: with external jacket and stages in stainless steel AISI 316.
Impellers
Radial impellers
6SDX(L) 18

Mixed flow impellers


6SDX(L) 30-46-65
8SDX(L) 78-97

Connection: Screwed connection ISO228


Delivery casing with built-in non-return valve.

Applications
For
For
For
For

water supply.
civil and industrial applications.
fire fighting applications.
irrigation.

Operating conditions
Liquid temperature up to 60 C (90 C for SDXL).
Max. sand quantity into the water: 100 g/m3.
Continuous duty.

Rewindable motor CS series


2-pole induction motor, 50 Hz (n 2900 rpm).
With water wetted winding in rewindable execution.
Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- three-phase 400 V; 400/690 V.
Voltage tolerance : +6% / -10%.
In order to limit both current and torque at each starting, for
rated motor powers equal to or higher than 7.5 kW, one of the
following types of starting is necessary: star/delta, soft starter,
stator impedance or autotransformer.
The electropumps 6SDX, 6SDXL series comply with the European Regulation
no. 547/2012.

Materials
Components
External jacket
Suction lantern
Upper cover
Delivery casing
Strainer
Valve set
O-ring valve
Shaft
Coupling set
Diffuser
Stage casing
Impeller
Wear ring
Bearing bush
Cable guard
Screws

6SDX
6SDXL
8SDX
8SDXL
Cr-Ni steel Cr-Ni-Mo steel Cr-Ni steel
Cr-Ni-Mo steel
AISI 304
AISI 316L
AISI 304
AISI 316
Cr-Ni-Mo steel AISI 316
Cr-Ni-Mo steel
Cr-Ni steel
Cr-Ni-Mo steel
AISI 316L
AISI 304
AISI 316
Cr-Ni-Mo steel
Cr-Ni-Mo steel
AISI 316
AISI 316
NBR
Cr-Ni-Mo steel AISI 316
Cr-Ni-Mo steel AISI 329
Cr-Ni-Mo steel AISI 316/329
Cr-Ni steel
Cr-Ni-Mo steel Cr-Ni steel
Cr-Ni-Mo steel
AISI 304
AISI 316L
AISI 304
AISI 316
Cr-Ni steel
Cr-Ni-Mo steel
Cr-Ni-Mo steel
AISI 304
AISI 316L
AISI 316
Teflon (PTFE)
NBR
HNBR
NBR
HNBR
Cr-Ni-Mo steel
AISI 316

CS, CS-R Motor


Components
External frame
Motor flange
Shaft end
Thrust bearing
Bushings

CS-R 6, 8, CS 10 standard

I-CS-R 6, 8, I-CS 10 AISI 316

AISI 304 (AISI 316Ti for 10)


Cast iron GJL 200 EN 1561

Cr-Ni-Mo steel AISI 316 Ti


Cr-Ni-Mo steel AISI 316
AISI 316 (AISI 630 from 30 to 93kW)
(AISI 429 for 10)
Oscillating pads
Graphite
(Bronze for 8 motor )

Steel AISI 431


(AISI 329 for 10)
Oscillating pads
Graphite
(Bronze for 8 motor )

378

Operating conditions motor


Motor

8CS-R

25 C

Cooling:
minimum
flow velocity
0,08 m/s
0,1 m/s
0,2 m/s
0,2 m/s
0,2 m/s
0,1 m/s
0,3 m/s
0,3 m/s

10CS

25 C

0,50 m/s

4CS
6CS-R

Max.
Liquid
temperature
35 C
30 C
25 C
40 C

Max.
starts
per hour
20
15
15
15
13
13
6
10
8
6
10

Motor
P2
all types
411 kW
1315 kW
18,5 kW
2230 kW
37 kW
45 kW
3045 kW
5175 kW
92 kW
all types

Insulation class F for 4 motors, class E for 6-8 motors, PVC


coated wire for 10 motors.
Motor suitable operation with frequency converter.
Protection IP 68.

Special features on request


- Other voltages.
- 60 Hz frequency.
- Other temperatures.
- Encapsulated motor FK series (for characteristic see pag. 404).

Designation
6 SDX L 30 / 17
of the well in inches
Series
Cr-Ni-Mo steel AISI 316 construction
Stage identification
Number of stages

SDX

Submersible borehole pumps for 6 and 8 wells

Coverage chart n 2900 rpm


30

40

20

50

30

40

U.S. g.p.m.
50

100

200

300

100

Imp. g.p.m.

200

400
300

500
400

500

700
2000
500

400

ft
1000

300

200

500

6SDX(L) 18

6SDX(L) 30

100

400

8SDX
(L)
8SDX
78
6SDX(L)
(L)
6SDX(L)
46
97
65

300

200

50
40
100

30

20
50
40
10

30

20
5

10

m 3/h

Q l/min
100

150

20
200

300

30
400

500

40

50

100
1000

150
2000
72.1161_10

43

379

6SDX 18

Submersible borehole pumps for 6 wells

Characteristic curves
0 U.S. g.p.m.

25

50

75

100

125

700
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6

600

500

400

300
H
m
200

100

0 Q m3/h

2200

6SDX 18
6SDXL 18

2000

1800

1600
ft
1400

1200

1000

800

600

400

200

0
5

10

15

20

25

30

80

1,0

(%)

0,8

60

kW/st

(%)

kW/st

0,6

40

0,4

20

0,2

0 Q m3/h

10

15

20

380

25

72.1163

0
30

6SDX 18

Submersible borehole pumps for 6 wells

Performance n 2900 rpm, dimensions and weights

3~

6SDX (L) 18/6


6SDX (L) 18/7
6SDX (L) 18/8
6SDX (L) 18/9
6SDX (L) 18/10
6SDX (L) 18/11
6SDX (L) 18/12
6SDX (L) 18/13
6SDX (L) 18/14
6SDX (L) 18/15
6SDX (L) 18/16
6SDX (L) 18/17
6SDX (L) 18/18
6SDX (L) 18/19
6SDX (L) 18/20
6SDX (L) 18/21
6SDX (L) 18/22
6SDX (L) 18/23
6SDX (L) 18/24
6SDX (L) 18/25
6SDX (L) 18/26
6SDX (L) 18/27
6SDX (L) 18/28
6SDX (L) 18/29
6SDX (L) 18/30
6SDX (L) 18/31
6SDX (L) 18/32
6SDX (L) 18/33
6SDX (L) 18/34
6SDX (L) 18/35
6SDX (L) 18/36
6SDX (L) 18/37
6SDX (L) 18/38
6SDX (L) 18/39
6SDX (L) 18/40
6SDX (L) 18/41
6SDX (L) 18/42
6SDX (L) 18/43
6SDX (L) 18/44
6SDX (L) 18/45
6SDX (L) 18/46
6SDX (L) 18/47
6SDX (L) 18/48
6SDX (L) 18/49
6SDX (L) 18/50
6SDX (L) 18/51
6SDX (L) 18/52
6SDX (L) 18/53
6SDX (L) 18/54
6SDX (L) 18/55
6SDX (L) 18/56
6SDX (L) 18/57
6SDX (L) 18/58
6SDX (L) 18/59
6SDX (L) 18/60

kW

HP

4
5,5
5,5
5,5
7,5
7,5
7,5
9,2
9,2
9,2
11
11
11
13 (15)
13 (15)
13 (15)
15
15
15
18,5
18,5
18,5
18,5
18,5
18,5
22
22
22
22
22
22
26 (30)
26 (30)
26 (30)
26 (30)
26 (30)
26 (30)
30
30
30
30
30
30
30
37
37
37
37
37
37
37
37
37
37
37

5,5
7,5
7,5
7,5
10
10
10
12,5
12,5
12,5
15
15
15
17,5 (20)
17,5 (20)
17,5 (20)
20
20
20
25
25
25
25
25
25
30
30
30
30
30
30
35 (40)
35 (40)
35 (40)
35 (40)
35 (40)
35 (40)
40
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50
50
50

DN

nn2900
2900rpm
1/min

P2

Motore

m3/h

10

12

15

18

21

24

27

l/min

133

167

200

250

300 350

400

450

70
81,7
93,3
105
117
128
140
152
163
175
187
198
210
222
233
245
257
268
280
292
303
315
327
338
350
362
373
385
397
408
420
432
443
455
467
478
490
502
513
525
537
548
560
572
583
595
607
618
630
642
653
665
677
688
700

62 57,6 51,6 43,2 32,9 20,5


66,4 64
77,5 74,7 72,3 67,2 60,2 50,4 38,4 23,9
88,5 85,3 82,7 76,8 68,8 57,6 43,9 27,4
93 86,4 77,4 64,8 49,4 30,8
99,6 96
86 72,0 54,9 34,2
111 107 103 96
122 117 114 106 94,6 79,2 60,4 37,6
133 128 124 115 103 86,4 65,8 41,0
144 139 134 125 112 93,6 71,3 44,5
155 149 145 134 120 101 76,8 47,9
166 160 155 144 129 108 82,3 51,3
177 171 165 154 138 115 87,8 54,7
188 181 176 163 146 122 93,3 58,1
199 192 186 173 155 130 98,8 61,6
210 203 196 182 163 137 104 65,0
221 213 207 192 172 144 110 68,4
232 224 217 202 181 151 115 71,8
243 235 227 211 189 158 121 75,2
254 245 238 221 198 166 126 78,7
266 256 248 230 206 173 132 82,1
277 267 258 240 215 180 137 85,5
288 277 269 250 224 187 143 88,9
299 288 279 259 232 194 148 92,3
310 299 289 269 241 202 154 95,8
321 309 300 278 249 209 159 99,2
332 320 310 288 258 216 165 103
343 331 320 298 267 223 170 106
354 342 331 307 275 230 176 109
365 352 341 317 284 238 181 113
376 363 351 326 292 245 187 116
387 373 362 336 301 252 192 120
398 384 372 346 310 259 198 123
409 395 382 355 318 266 203 127
420 405 393 365 327 274 209 130
432 416 403 374 335 281 214 133
443 427 413 384 344 288 220 137
454 437 424 394 353 295 225 140
465 448 434 403 361 302 230 144
476 459 444 413 370 310 236 147
487 469 455 422 378 317 241 151
498 480 465 432 387 324 247 154
509 491 475 442 396 331 252 157
520 501 486 451 404 338 258 161
531 512 496 461 413 346 263 164
542 523 506 470 421 353 269 168
553 533 517 480 430 360 274 171
564 544 527 490 439 367 280 174
575 555 537 499 447 374 285 178
586 565 548 509 456 382 291 181
598 576 558 518 464 389 296 185
609 587 568 528 473 396 302 188
620 597 579 538 482 403 307 192
631 608 589 547 490 410 313 195
642 619 599 557 499 418 318 198
653 629 610 566 507 425 324 202
664 640 620 576 516 432 329 205

DN

Rp
21/2

CS-R

FK

mm

mm

145
6"

137
6"

f
mm

kg

494
532
569
607
644
682
719
757
794
832
869
907
944
982
1019
1057
1094
1132
1169
1207
1244
1282
1319
1356
1394
1431
1469
1506
1544
1581
1619
1656
1694
1731
1769
1806
1844
1881
1919
1956
1993
2031
2068
2106
2143
2181
2218
2256
2293
2331
2368
2406
2443
2481
2518

12,5
13,5
14,3
15
16
17
17,5
18,5
19,3
20
21
22
22,5
23,5
24
25
26
26,5
27,5
28,3
29
31
31
31,5
32,5
33,3
34
35
35,7
36,3
37
38,4
39,8
40
40,5
41,8
43
44
45
46
47
47,5
48
50
51
52
53
54
55
56
57
58
59
60
61

135

6"

14

14

43

Reinforced with special


collar from 6SDX(L) 18/47
P2 Rated motor power output

(...) FK motor rated power output

H Total head in m

381

Tolerances according to UNI EN ISO 9906:2012

6SDX 30

Submersible borehole pumps for 6 wells

Characteristic curves

U.S. g.p.m.

50

100

150

190

700

600

2000

37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3

500

400

m
300

200

100

2200

6SDX 30
6SDXL 30

43
42
41
40
39
38

0 Q m3/h 5

1800

1600

1400
ft
1200

1000

800

600

400

200

10

15

20

25

30

35

40

45

100

1,6

1,4

80

(%)

kW/st

(%)
60

1,2

kW/st
40

1,0

0,8

2900 rpm
2850 rpm

0 Q m3/h 5

10

15

20

25

382

30

35

40

72.1164

45

20

6SDX 30

Submersible borehole pumps for 6 wells

Performance n 2900 rpm, dimensions and weights

3~

6SDX (L) 30/3


6SDX (L) 30/4
6SDX (L) 30/5
6SDX (L) 30/6
6SDX (L) 30/7
6SDX (L) 30/8
6SDX (L) 30/9
6SDX (L) 30/10
6SDX (L) 30/11
6SDX (L) 30/12
6SDX (L) 30/13
6SDX (L) 30/14
6SDX (L) 30/15
6SDX (L) 30/16
6SDX (L) 30/17
6SDX (L) 30/18
6SDX (L) 30/19
6SDX (L) 30/20
6SDX (L) 30/21
6SDX (L) 30/22
6SDX (L) 30/23
6SDX (L) 30/24
6SDX (L) 30/25
6SDX (L) 30/26
6SDX (L) 30/27
6SDX (L) 30/28
6SDX (L) 30/29
6SDX (L) 30/30
6SDX (L) 30/31
6SDX (L) 30/32
6SDX (L) 30/33
6SDX (L) 30/34
6SDX (L) 30/35
6SDX (L) 30/36
6SDX (L) 30/37
6SDX (L) 30/38
6SDX (L) 30/39
6SDX (L) 30/40
6SDX (L) 30/41
6SDX (L) 30/42
6SDX (L) 30/43

kW

HP

4
5,5
7,5
7,5
9,2
11
11
13 (15)
15
15
18,5
18,5
22
22
22
22
26 (30)
26 (30)
26 (30)
30
30
30
37
37
37
37
37
37
45
45
45
45
45
45
45
51 (55)
51 (55)
51 (55)
51 (55)
55
55

5,5
7,5
10
10
12,5
15
15
17,5 (20)
20
20
25
25
30
30
30
30
35 (40)
35 (40)
35 (40)
40
40
40
50
50
50
50
50
50
60
60
60
60
60
60
60
70 (75)
70 (75)
70 (75)
70 (75)
75
75

DN

nn2900
29001/min
rpm

P2

Motore

m3/h

15

20

25

30

35

40

45

l/min

250

333

416

500

583 666

750

46,3
62,5
78,6
93,1
110
125
140
158
173
188
205
220
237
252
267
281
302
317
332
347
362
377
395
410
425
440
454
469
490
505
520
535
549
564
579
613
628
644
659
675
690

38,9
52,6
66,2
78,4
92,6
106
118
133
146
158
173
185
200
212
224
237
255
267
280
293
305
317
333
345
358
370
383
395
413
425
438
450
463
475
487
517
530
543
557
569
582

36
48,8
61,5
72,6
86
98,1
109
124
135
147
161
172
185
197
208
220
237
249
260
272
283
295
309
321
332
344
355
366
384
395
407
418
429
441
452
482
494
506
518
530
542

33,3
45,2
56,9
67,1
79,7
90,9
101
115
125
136
149
159
172
183
193
203
220
231
241
252
263
273
287
297
308
318
329
339
356
366
377
387
398
408
418
448
459
471
482
493
504

30,2
41,1
51,8
61
72,6
82,7
91,8
105
114
123
136
145
157
166
176
185
201
210
220
230
239
249
261
271
280
290
299
308
324
334
343
353
362
371
380
410
420
430
440
450
460

15,3
21,4
27,4
31,2
38,4
43,5
47,3
56,1
60,4
64,4
72,4
76,7
84
88,3
92,5
96,5
109
114
118
123
127
131
140
144
149
153
157
161
174
178
182
186
190
194
198
229
234
240
245
250
255

H
m

26,7
36,5
46,1
54
64,6
73,6
81,4
93,5
102
110
121
129
140
148
156
164
180
188
197
205
213
221
233
242
250
258
266
274
289
298
306
314
322
330
338
369
378
387
396
404
413

21,7
30
38
44,1
53,3
60,5
66,6
77,3
83,8
90
100
106
116
122
129
135
149
156
163
169
176
182
193
200
206
212
219
225
239
246
252
259
265
271
277
309
316
323
330
338
345

DN

CS-R

FK

mm

mm

145
6"

137
6"

Rp
3

191
8"

196
8"

f
mm
620
705
790
876
961,5
1047
1132
1218
1303
1389
1474
1560
1645
1730
1816
1901
1987
2072
2157
2243
2328
2414
2499
2584
2670
2755
2840
2926
3011
3096
3182
3267
3352
3438
3523
3709
3794
3879
3965
4050
4135

kg
14,7
16,8
18,9
21
23,1
25,4
27,3
29,4
31,5
33,6
35,7
37,8
39,9
42
44,1
46,1
48,2
50,3
52,4
54,5
56,6
58,7
60,8
62,9
65
67,2
69,2
71,3
75,2
78,3
80,4
82,5
84,6
87,9
90
92,3
94,5
96,6
97,6
98,7
99,8

135

4", 6"

188

8"

8")
1(
19 (6")

7
14

8")
)
1(
19 4",6"
4(
14

43

Reinforced with special


collar from 6SDX(L) 30/36
P2 Rated motor power output

(...) FK motor rated power output

H Total head in m

383

Tolerances according to UNI EN ISO 9906:2012

6SDX 46

Submersible borehole pumps for 6 wells

Characteristic curves

560

500

400

H
m

300

200

100

0 U.S. g.p.m.

50

100

150

200

250
1800

40
39
38
37
36
35
34

1700

6SDX 46
6SDXL 46

1600
1500

33
32
31
30
29

1400

28
27
26
25
24
23
22
21
20
19
18

1200

1300

1100
ft
1000
900
800

17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2

0 Q m3/h

700
600
500
400
300
200
100

10

20

30

40

50

60

1,6

0
100

1,4

(%)

2900 rpm

80

(%)

kW/st

2850 rpm

1,2

60

kW/st

1,0

40

0,8
0 Q m3/h

10

20

30

384

40

50

72.1165

20
60

6SDX 46

Submersible borehole pumps for 6 wells

Performance n 2900 rpm, dimensions and weights

3~

P2

kW
6SDX (L) 46/2
6SDX (L) 46/3
6SDX (L) 46/4
6SDX (L) 46/5
6SDX (L) 46/6
6SDX (L) 46/7
6SDX (L) 46/8
6SDX (L) 46/9
6SDX (L) 46/10
6SDX (L) 46/11
6SDX (L) 46/12
6SDX (L) 46/13
6SDX (L) 46/14
6SDX (L) 46/15
6SDX (L) 46/16
6SDX (L) 46/17
6SDX (L) 46/18
6SDX (L) 46/19
6SDX (L) 46/20
6SDX (L) 46/21
6SDX (L) 46/22
6SDX (L) 46/23
6SDX (L) 46/24
6SDX (L) 46/25
6SDX (L) 46/26
6SDX (L) 46/27
6SDX (L) 46/28
6SDX (L) 46/29
6SDX (L) 46/30
6SDX (L) 46/31
6SDX (L) 46/32
6SDX (L) 46/33
6SDX (L) 46/34
6SDX (L) 46/35
6SDX (L) 46/36
6SDX (L) 46/37
6SDX (L) 46/38
6SDX (L) 46/39
6SDX (L) 46/40

HP

3
4
4
5,5
5,5
7,5
7,5
10
9,2
12,5
9,2
12,5
11
15
13 (15) 17,5 (20)
13 (15) 17,5 (20)
20
15
25
18,5
25
18,5
25
18,5
30
22
30
22
30
22
26 (30) 35 (40)
26 (30) 35 (40)
40
30
40
30
40
30
40
30
50
37
50
37
50
37
50
37
50
37
60
45
60
45
60
45
60
45
60
45
51 (55) 70 (75)
51 (55) 70 (75)
51 (55) 70 (75)
51 (55) 70 (75)
75
55
75
55
75
55

m3/h

25

l/min

416 500

H
m

DN

29001/min
rpm
nn2900

26,4
39,4
52,5
66,1
80,7
93,1
106
121
134
146
161
174
186
201
213
225
244
257
269
282
294
307
322
335
347
360
372
390
403
415
427
440
469
482
496
509
522
535
548

22,6
33,8
45
56,8
70
80,4
91,6
105
116
126
140
150
161
174
184
195
212
223
234
244
255
265
280
290
301
311
321
339
349
360
370
380
411
422
434
445
456
467
479

30

20,9
31,2
41,5
52,3
65,2
74,8
85,1
98,2
108
118
130
140
149
162
171
181
198
208
218
227
237
247
260
270
280
289
299
315
325
334
344
353
383
394
404
415
425
436
446

35

40

583 666
19,3
28,8
38,3
48,3
60,4
69,3
78,9
91
100
109
12
130
139
150
159
168
183
192
208
211
220
229
241
250
259
268
277
292
301
310
319
328
355
365
374
384
394
403
413

17,8
26,6
35,5
44,7
55,5
63,5
72,2
83,7
91,9
99,9
111
119
127
138
146
154
169
177
185
193
202
209
222
230
238
246
254
268
276
284
292
300
328
337
346
355
364
372
381

45

Motore
50

55

60

750 833 916 1000


16,6
24,7
32,9
41,5
50,3
57,6
65,5
75,9
83,3
90,5
101
108
115
125
132
139
153
160
168
175
183
190
201
208
216
223
230
243
251
258
265
272
298
306
314
322
330
338
346

15,1
22,5
29,9
37,8
46
52,7
59,9
69,5
76,2
82,8
92
98,7
105
114
121
127
140
147
154
160
167
174
184
191
197
204
210
223
229
236
243
249
272
279
287
294
302
309
316

13,4
19,9
26,5
33,6
41,6
47,5
54
62,9
68,9
74,7
83,3
89,2
95
103
109
115
127
133
139
145
151
157
166
172
178
184
190
201
207
213
219
225
248
255
261
268
275
281
288

11,3
16,8
22,3
28,4
35,7
40,5
46
54,1
59
63,7
71,4
76,3
81
88,4
93,2
97,8
109
114
119
124
129
134
143
147
152
157
162
173
178
183
187
192
216
221
227
233
238
244
249

DN

CS-R

FK

mm

mm

f
mm

kg

96 - 4" 96 - 4" 594


705
819
933
1047
1161
1275
1389
1503
1617
1730
1844
1958
145 137 2072
6"
6"
2186
2300
2414
2527
Rp
2641
3
2755
2869
2983
3096
3210
3324
3438
3552
3665
3779
3893
4007
4121
4335
4449
4562
191 196 4676
8"
8"
4790
4904
5018

13,5
16,2
18,8
21,4
24,0
26,6
29,2
31,8
34,4
37,0
39,6
42,2
44,8
47,4
50,1
52,7
55,3
57,9
60,5
63,1
65,7
68,3
70,9
73,5
76,1
79,3
82,0
87,4
90,0
92,6
95,2
97,8
101
103
106
109
111
114
117

135

4", 6"

188

8"

8")
1(
19
6")

7(
14

8")
)
1(
19 4",6"
(
4
14

43

Reinforced with special


collar from 6SDX(L) 46/27
P2 Rated motor power output

(...) FK motor rated power output

H Total head in m

385

Tolerances according to UNI EN ISO 9906:2012

6SDX 65

Submersible borehole pumps for 6 wells

Characteristic curves

U.S. g.p.m.

100

150

200

250

300

350

450
1400

31

6SDX 65
6SDXL 65

30
400

29
28
27

1300

1200
350

26
1100

25
24
23
300

22

H
m

21

250

1000
ft
900

20
19

800

18
17

200

16
15

700

14

600

13
12
150

500

11
10

400

9
8
100

300

6
5
50

200

4
3

100

2
0

0 Q m3/h 10

20

30

40

50

60

70

80

90

2,0

100

(%)

1,8
kW/st
1,6

80

(%)

kW/st

60

2900 rpm

1,4

40
2850 rpm

1,2

0 Q m3/h 10

20

30

40

50

386

60

70

80

72.1166

20
90

6SDX 65

Submersible borehole pumps for 6 wells

Performance n 2900 rpm, dimensions and weights

3~
kW
6SDX (L) 65/2
6SDX (L) 65/3
6SDX (L) 65/4
6SDX (L) 65/5
6SDX (L) 65/6
6SDX (L) 65/7
6SDX (L) 65/8
6SDX (L) 65/9
6SDX (L) 65/10
6SDX (L) 65/11
6SDX (L) 65/12
6SDX (L) 65/13
6SDX (L) 65/14
6SDX (L) 65/15
6SDX (L) 65/16
6SDX (L) 65/17
6SDX (L) 65/18
6SDX (L) 65/19
6SDX (L) 65/20
6SDX (L) 65/21
6SDX (L) 65/22
6SDX (L) 65/23
6SDX (L) 65/24
6SDX (L) 65/25
6SDX (L) 65/26
6SDX (L) 65/27
6SDX (L) 65/28
6SDX (L) 65/29
6SDX (L) 65/30
6SDX (L) 65/31

HP

5,5
4
7,5
5,5
10
7,5
12,5
9,2
15
11
13 (15) 17,5 (20)
20
15
20
15
25
18,5
25
18,5
30
22
30
22
26 (30) 35 (40)
26 (30) 35 (40)
40
30
40
30
50
37
50
37
50
37
50
37
60
45
60
45
60
45
60
45
60
45
51 (55) 70 (75)
51 (55) 70 (75)
51 (55) 70 (75)
75
55
75
55

m3/h

35

l/min

583 666

H
m

DN

2900
n n2900
1/minrpm

P2

26,8
40,4
54
68
81,2
94,9
108
120
134
147
161
174
190
203
216
229
243
256
269
281
298
310
323
336
348
373
386
399
413
426

21,1
31,8
42,5
53,8
64
76,2
86
95,5
108
117
129
138
153
163
173
183
195
205
215
225
239
249
259
268
278
303
313
324
334
345

40

19
28,8
38,4
48,7
57,9
70,1
79,1
87,8
99
108
118
127
141
150
159
168
180
189
198
206
220
229
238
247
255
279
288
298
308
317

45

50

750 833
17,3
26,2
35
44,3
52,7
65,2
73,5
81,5
91,9
100
110
118
131
140
148
156
167
175
184
192
204
213
221
229
237
259
268
277
286
295

16,5
24,9
33,2
41,9
50
61,7
69,7
77,4
87,2
95
104
112
124
132
140
148
158
166
174
182
194
202
209
217
225
245
253
262
270
279

55

Motore

60

65

70

75

80

DN

916 1000 1083 1166 1250 1333


15,7
23,7
31,6
40,1
47,7
58,6
66,1
73,4
82,7
90
99,1
106
118
126
133
141
150
158
165
173
184
191
199
206
213
233
241
249
258
265

14,9
22,5
30,1
38,2
45,3
55,7
62,8
69,6
78,5
85,4
94,1
101
112
119
126
133
143
150
157
164
175
182
189
196
202
222
229
237
245
252

13,9
21
28
35,6
42,3
52,1
58,5
64,6
73,2
79,4
87,6
93,8
105
111
118
124
133
140
146
152
163
170
176
182
188
208
216
223
230
237

12,4
18,9
25,2
32,2
38,1
46,1
51,6
56,8
64,6
69,8
77,3
82,5
93
98,7
104
110
118
123
129
134
144
150
155
161
166
186
193
199
205
211

10,5
16
21,4
27,5
32,3
39,7
44,3
48,6
55,5
59,9
66,3
70,8
80,2
85
89,7
94,3
101
106
111
115
124
129
133
138
142
162
167
172
177
183

8,2
12,6
16,9
22
25,7
33,4
37
40,2
46,3
49,6
55,3
58,6
67,7
71,5
75,2
78,8
85,2
88,9
92,4
95,7
104
108
111
115
118
137
142
146
151
155

CS-R

FK

mm

mm

145
6"

137
6"

Rp
3

191
8"

196
8"

f
mm

kg

592
705
819
933
1047
1161
1275
1389
1503
1617
1730
1844
1958
2072
2186
2300
2414
2527
2641
2755
2869
2983
3096
3210
3324
3538
3652
3765
3879
3993

13,6
16,2
18,8
21,4
24,0
26,7
29,3
31,9
34,5
37,1
39,7
42,4
44,9
47,5
50,2
52,8
55,4
58,0
60,7
63,3
68,7
71,3
73,9
76,5
79,1
82,6
85,3
87,9
90,5
93,2

135

188

6"

8"

8")
1(
19
6")

7(
14

8")
1 ( ")
19
6
4(
14

43

Reinforced with special


collar from 6SDX(L) 65/27
P2 Rated motor power output

(...) FK motor rated power output

H Total head in m

387

Tolerances according to UNI EN ISO 9906:2012

8SDX 78

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


100 U.S. g.p.m. 200

50

250

300

350

400

450

540

23
22

DN

1700
ft
1600

8SDX 78
8SDXL 78

24

500

1500

21

400

20

1400

19

1300

18
1200

17
16

m
300

1100

15

13

900

12

800

11

700

10
9

200

1000

14

600

8
500

7
6

170,5

6"

400

5
4

300

200

100

2
100
0
0

Q m3/h

20

30

40

50

60

70

80

90

100

110

4,4

8"

188

100
(%)

4,0
3,6
kW/st
3,2

8")
5 ( ")
19
6

7(
18

80
60
(%)
40

kW/st

2,8

8")
8(
19
6")
2(
19

20

2,4
0

Q m3/h

20

30

40

3~

8SDX 78/2
8SDX 78/3
8SDX 78/4
8SDX 78/5
8SDX 78/6
8SDX 78/7
8SDX 78/8
8SDX 78/9
8SDX 78/10
8SDX 78/11
8SDX 78/12
8SDX 78/13
8SDX 78/14
8SDX 78/15
8SDX 78/16
8SDX 78/17
8SDX 78/18
8SDX 78/19
8SDX 78/20
8SDX 78/21
8SDX 78/22
8SDX 78/23
8SDX 78/24

50

60

m3 /h

P2 Rated motor power output

80

30

90

100

kW

HP

7,5
11
15
18,5
22
26 (30)
30
37
37
45
45
51 (55)
51 (55)
55
59 (75)
66 (75)
66 (75)
75
75
75
92
92
92

10
15
20
25
30
35 (40)
40
50
50
60
60
70 (75)
70 (75)
75
80 (100)
90 (100)
90 (100)
100
100
100
125
125
125

l/min

H
m

72.1167

110

2900
n n 2900
rpm1/min

P2

- 8SDXL 78/2
- 8SDXL 78/3
- 8SDXL 78/4
- 8SDXL 78/5
- 8SDXL 78/6
- 8SDXL 78/7
- 8SDXL 78/8
- 8SDXL 78/9
- 8SDXL 78/10
- 8SDXL 78/11
- 8SDXL 78/12
- 8SDXL 78/13
- 8SDXL 78/14
- 8SDXL 78/15
- 8SDXL 78/16
- 8SDXL 78/17
- 8SDXL 78/18
- 8SDXL 78/19
- 8SDXL 78/20
- 8SDXL 78/21
- 8SDXL 78/22
- 8SDXL 78/23
- 8SDXL 78/24

70

40

50

60

70

80

Motor
90

100

500

666

833

1000 1166 1333 1500 1666

39,9
59,8
79,7
99,6
120
140
156
176
195
215
248
268
289
310
332
353
374
394
415
436
457
478
499

37,1
55,7
74,3
92,9
111
130
146
164
183
201
232
251
271
290
312
332
351
371
390
409
428
448
467

34,9
52,3
69,7
87,1
105
122
138
155
173
190
218
237
255
273
293
311
329
348
366
385
403
422
440

32,6
48,9
65,1
81,4
97,7
114
128
144
160
176
203
220
237
254
274
292
309
326
343
361
378
395
412

29,7
44,6
59,4
74,3
89,1
104
117
132
147
162
187
203
218
234
252
268
284
299
315
331
347
363
379

(...) FK motor rated power output

27,1
40,7
54,3
67,9
81,4
95
107
120
134
147
171
185
200
214
232
247
261
276
290
304
318
333
347

H Total head in m

388

24,3
36,4
48,6
60,7
72,9
85
94,5
106
118
130
154
166
179
192
206
219
232
245
258
271
284
297
310

20,4
30,6
40,9
51,1
61,3
71,5
80
90
100
110
130
141
152
163
176
187
198
209
220
231
242
253
264

16,3
24,4
32,6
40,7
48,9
57
63,3
71,2
79,1
87
105
114
122
131
143
152
161
170
179
187
196
205
214

DN

CS-R
mm

FK
mm

145
6"

137
6"

191
8"

196
8"

Rp
5

8SDXL

mm

kg

644
770
896
1022
1148
1274
1400
1526
1652
1778
1909
2035
2161
2287
2413
2539
2665
2791
2917
3043
3169
3295
3421

31,5
36,5
41,5
46,5
51
56
61
66
71
76
82
87
92
97
101,5
106,5
111,5
116,5
121
126
131
136
141

Tolerances according to UNI EN ISO 9906:2012

8SDX 97

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0 U.S. g.p.m. 100

150

200

250

300

350

400

450

500

550

540
23
500

22
21

1500

20

1400

19
18

400

DN

1700
ft
1600

8SDX 97
8SDXL 97

1300

17

16

1200

15

1100

14

1000

300

13
12

900

11

800

10
700
200

9
600

8
7

500

170,5

6
5
4

300

200

100

6"

400

100
0
0

Q m3/h 20

30

40

50

60

70

80

90

100

110

120

130

8"-10"

188

100
(%)

4,6
4,2
kW/st
3,8

60
(%)
40

kW/st

3,4

8")
8(
19
6")

2(
19

8")
5 ( ")
19
6

7(
18

80

20

3
0

Q m3/h 20

30

40

50

3~

- 8SDXL 97/2
- 8SDXL 97/3
- 8SDXL 97/4
- 8SDXL 97/5
- 8SDXL 97/6
- 8SDXL 97/7
- 8SDXL 97/8
- 8SDXL 97/9
- 8SDXL 97/10
- 8SDXL 97/11
- 8SDXL 97/12
- 8SDXL 97/13
- 8SDXL 97/14
- 8SDXL 97/15
- 8SDXL 97/16
- 8SDXL 97/17
- 8SDXL 97/18
- 8SDXL 97/19
- 8SDXL 97/20
- 8SDXL 97/21
- 8SDXL 97/22
- 8SDXL 97/23

P2 Rated motor power output

70

80

90

100

110

HP

12,5
9,2
13 (15) 17,5 (20)
25
18,5
30
22
26 (30) 35 (40)
40
30
50
37
50
37
60
45
51 (55) 70 (75)
51 (55) 70 (75)
75
55
59 (75) 80 (100)
66 (75) 90 (100)
100
75
100
75
125
92
125
92
125
92
125
92
150
110
150
110

m /h

40

l/min

666

41,2
61,8
82,4
103
125
146
167
188
219
241
263
285
309
331
353
375
397
419
440
462
484
507

72.1168

120

130

2900rpm
1/min
nn2900

P2
kW

8SDX 97/2
8SDX 97/3
8SDX 97/4
8SDX 97/5
8SDX 97/6
8SDX 97/7
8SDX 97/8
8SDX 97/9
8SDX 97/10
8SDX 97/11
8SDX 97/12
8SDX 97/13
8SDX 97/14
8SDX 97/15
8SDX 97/16
8SDX 97/17
8SDX 97/18
8SDX 97/19
8SDX 97/20
8SDX 97/21
8SDX 97/22
8SDX 97/23

60

50

70

80

90

Motor
100

110

120

DN

833 1000 1166 1333 1500 1666 1833 2000

38,6 35,2
57,9 52,8
77,2 70,4
96,5 88
113 105
132 123
151 140
170 158
200 185
220 204
240 222
260 241
281 262
302 279
322 298
342 317
362 335
382 354
403 374
424 393
444 411
464 430

(...) FK motor rated power output

60

32,2
48,3
64,4
80,5
96,7
113
129
145
172
189
206
223
242
261
278
295
313
330
348
365
383
400

29,8
44,7
59,6
74,5
89
104
119
134
158
174
190
206
224
240
256
272
288
304
322
338
354
370

27,8
41,7
55,6
69,5
82,7
96,4
110
124
147
162
176
191
208
222
237
251
266
281
298
313
328
343

H Total head in m

389

24,8
37,2
49,6
62
75
87,5
100
113
135
149
162
176
191
205
219
233
246
260
274
288
301
315

21,8
32,7
43,6
54,5
66,3
77,4
88,4
99,5
119
131
143
155
169
182
194
206
218
230
244
257
269
281

18,6
27,9
37,2
46,5
55
64,2
73,3
82,5
102
112
122
132
144
156
166
176
187
197
209
219
230
240

14,8
22,2
29,6
37
44
51,3
58,7
66
83,1
91,4
99,7
108
120
129
138
147
155
164
173
182
190
199

CS-R
mm

145
6"

FK
mm

137
6"

Rp
5
191
8"
196
8"

240
10"

f
mm

644
770
896
1022
1148
1274
1400
1526
1657
1783
1909
2035
2161
2287
2413
2539
2665
2791
2917
3043
3169
3295

Tolerances according to UNI EN ISO 9906:2012

8SDXL
kg

31,5
36,5
41,5
46
51
56
61
66
72
77
82
87
92
97
102
106,5
111,5
116,5
121
126
131
136

43

390

09/2016

SDS

Submersible borehole pumps for 6,8 and 10 wells


Construction
Submersible borehole pumps for 6 wells (DN 150 mm),
8 (DN 200 mm) and 10 (DN 250 mm), with stages in cast
iron or in bronze, on request.
Impellers: - mixed flow impellers.
Connection: - screwed connection ISO228 for 6SDS;
- flange with counter-flange for welding for 8SDS
and 10SDS
Delivery casing with built-in non-return valve.

Applications
For
For
For
For

water supply.
civil and industrial applications.
fire fighting applications.
irrigation.

Operating conditions
Liquid temperature up to a 25 C.
Max. sand quantity into the water: 150 g/m3.
Continuous duty.

Rewindable motor CS, CS-Rseries


2-pole induction motor, 50 Hz (n 2900 rpm).
With water wetted winding in rewindable execution.
Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- three-phase 400 V; 400/690 V.
Voltage tolerance : +6% / -10%.
In order to limit both current and torque at each starting, for
rated motor powers equal to or higher than 7.5kW, one of the
following types of starting is necessary: star/delta, soft starter,
stator impedance or autotransformer.

Operating conditions motor


Motor

8CS-R

25 C

Cooling:
minimum
flow velocity
0,1 m/s
0,2 m/s
0,2 m/s
0,2 m/s
0,1 m/s
0,3 m/s
0,3 m/s

10CS

25 C

0,50 m/s

6CS-R
6SDS series cannot be sold in the EU.

25 C

Materials
Components
Stage casing
Diffuser
Impeller
Wear ring
Shaft

Shaft sleeve
Delivery casing
Suction lantern
Bearing bush
Strainer

Max.
Liquid
temperature
30 C

40 C
Part Nr.
25.02
26.00
28.00
64.00

64.08
12.01
32.02
12.03-12.30
15.50

Screws

6, 8, 10SDS

B-6, B-8, B-10SDS

Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982

Rubber (Bronze for 10SDS 190-280)


6SDS e 8SDS:
Steel AISI F51duplex
Cr-Ni-Mo steel
AISI 316
10SDS
Cr steel AISI 420
Brass with chromate surface treatment (only for 10SDS)
Cast iron
GJL 200 EN 1561

Bronze
G-Cu Sn 10 EN 1982
Rubber
Cr-Ni steel AISI 304
Cr-Ni steel AISI 304

Max.
starts
per hour
15
15
15
13
13
6
10
8
6
10

Motor
P2
411 kW
1315 kW
18,5 kW
2230 kW
37 kW
45 kW
3045 kW
5175 kW
92 kW
all types

Insulation class E for 6-8 motors, PVC coated wire for 10


motors.
Motor suitable operation with frequency converter.
Protection IP 68.

Special features on request


- Other voltages.
- 60 Hz frequency.
- Other temperatures.
- Encapsulated motor FK series (for characteristic see pag. 404).

CS, CS-R Motor


Components
External frame
Motor flange
Shaft end
Thrust bearing
Bushings

CS-R 6, 8, CS 10 standard I-CS-R 6, 8, I-CS 10 AISI 316


AISI 304 (AISI 316Ti for 10)
Cast iron GJL 200 EN 1561

Steel AISI 431


(AISI 329 for 10)
Oscillating pads
Graphite
(Bronze for 8 motor )

Cr-Ni-Mo steel AISI 316 Ti


Cr-Ni-Mo steel AISI 316
AISI 316 (AISI 630 from 30 to 93kW)
(AISI 429 for 10)
Oscillating pads
Graphite
(Bronze for 8 motor )

391

Designation
Bronze construction (on request)
of the well in inches
Series
Stage identification
Number of stages

B 10 SDS 190 / 6

44

SDS

Submersible borehole pumps for 6,8 and 10 wells

Coverage chart n 2900 rpm


50
40

U.S. g.p.m.

100
50

100

200

300

Imp. g.p.m.

200

400
300

500
400

1000
500

1500
1000

500

1500

400

SDS

300
8SDS 70

200

1000

10SDS
160

ft

500

6
SDS
42

6SDS 32

100

400
300
6SDS 58
8SDS 100

50

8SDS 150

200

10SDS 10SDS 280


190

40
100

30
20

50
40
10

30
20

5
10
200

m3/h
20
l/min 300

400

30
500

40

50

100
1000

2000

200
3000

4000

300
5000

400
6000
72.1003/2

392

6SDS 32

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0 U.S. g.p.m. 50
0

Imp. g.p.m.

100
50

150
100

200
150

340
DN

23
300

6SDS 32
B-6SDS 32

22
21

1000

H
ft

20

CALPEDA

19

18

800

17
16
15

200

14
600

13
12
11
10
9

400

8
100

7
3.93.065/1

6
5
200

14

0
m 3/h
Q l/min
0
0

10
200

l/s

20
400

P2 Rated motor power output

50

4
5,5
7,5
7,5
9,2
11
13 (15)
13 (15)
15
15
18,5
18,5
22
22
22
26 (30)
26 (30)
26 (30)
26 (30)
30
30

5,5
7,5
10
10
12,5
15
17,5 (20)
17,5 (20)
20
20
25
25
30
30
30
35 (40)
35 (40)
35 (40)
35 (40)
40
40

2900 rpm

m /h

12

18

21

24

27

30

33

36

39

42

l/min

200

300

350

400

450

500

550

600

650

39
52
65
78
92
105
118
131
144
157
170
183
196
209
223
236
246
262
275
288
301

37 35,5 33,5 31,5 30 26,5


42 39,5 35,5
45
47
49
56 52,5 49,5 44,5
61,5 59
63 59,5 53,5
67
71
74
62
86 82,5 78,5 73,5 69
71
79
98,5 94,5 89,5 84
80
111 106 101 94,5 89
89
99
123 118 112 105
98
135 130 123 115 109
147 141 134 126 119 107
160 153 145 136 129 116
172 165 157 147 138 124
184 177 168 157 148 133
197 189 179 168 158 142
209 200 190 178 168 151
221 212 201 189 178 160
234 224 213 199 188 169
246 236 224 210 198 178
258 248 235 220 208 187
270 259 246 231 218 196
283 271 257 241 228 205

24
32
40
48
56
64
72
80
88
96
104
112
120
128
136
144
152
160
168
176
184

21
28
35
42
49
56
63
70
77
84
91
98
105
112
119
126
133
140
147
154
161

H
m

72.1039

P2

HP

15

800

10

kW
- B-6SDS 32/3
- B-6SDS 32/4
- B-6SDS 32/5
- B-6SDS 32/6
- B-6SDS 32/7
- B-6SDS 32/8
- B-6SDS 32/9
- B-6SDS 32/10
- B-6SDS 32/11
- B-6SDS 32/12
- B-6SDS 32/13
- B-6SDS 32/14
- B-6SDS 32/15
- B-6SDS 32/16
- B-6SDS 32/17
- B-6SDS 32/18
- B-6SDS 32/19
- B-6SDS 32/20
- B-6SDS 32/21
- B-6SDS 32/22
- B-6SDS 32/23

40
600

3~

6SDS 32/3
6SDS 32/4
6SDS 32/5
6SDS 32/6
6SDS 32/7
6SDS 32/8
6SDS 32/9
6SDS 32/10
6SDS 32/11
6SDS 32/12
6SDS 32/13
6SDS 32/14
6SDS 32/15
6SDS 32/16
6SDS 32/17
6SDS 32/18
6SDS 32/19
6SDS 32/20
6SDS 32/21
6SDS 32/22
6SDS 32/23

30

(...) FK motor rated power output

H Total head in m

393

DN

6SDS

B-6SDS

700

mm

kg

kg

18
24
30
36
42
48
54
60
66
72
78
84
90
96
102
108
114
120
126
132
138

686
788
890
992
1094
1196
1298
1400
1502
1604
1706
1808
1910
2012
2114
2216
2318
2420
2522
2624
2726

30,5
35,6
41
46
52,3
57
62,5
68,5
72,5
77,5
84
89
94,2
100
105
111
116
122
127
132
137

35,5
41,6
49
55
62,3
68
74,5
81,5
86,5
93,5
101
108
112
119
125
132
139
145
151
157
164

G3
ISO 228

Tolerances according to UNI EN ISO 9906:2012

44

6SDS 42

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


U.S. g.p.m.

100

150

0 Imp. g.p.m. 50

200

100

250

150

200

300
DN

6SDS 42
B-6SDS 42
250

800

18

17

16

200

15

CALPEDA

H
ft

14

600

13

12
150

11
10
9

400

8
100

7
6

3.93.065/1

5
200

4
50

14

15

0 0
m 3/h 10
Q l/min
0
200
0

l/s

20

30
400

- B-6SDS 42/2
- B-6SDS 42/3
- B-6SDS 42/4
- B-6SDS 42/5
- B-6SDS 42/6
- B-6SDS 42/7
- B-6SDS 42/8
- B-6SDS 42/9
- B-6SDS 42/10
- B-6SDS 42/11
- B-6SDS 42/12
- B-6SDS 42/13
- B-6SDS 42/14
- B-6SDS 42/15
- B-6SDS 42/16
- B-6SDS 42/17
- B-6SDS 42/18

P2 Rated motor power output

600

0
60
1000

50
800
15

10

72.1040

3~

6SDS 42/2
6SDS 42/3
6SDS 42/4
6SDS 42/5
6SDS 42/6
6SDS 42/7
6SDS 42/8
6SDS 42/9
6SDS 42/10
6SDS 42/11
6SDS 42/12
6SDS 42/13
6SDS 42/14
6SDS 42/15
6SDS 42/16
6SDS 42/17
6SDS 42/18

40

P2

kW

HP

4
5,5
7,5
9,2
11
13 (15)
15
15
18,5
18,5
22
22
26 (30)
26 (30)
30
30
30

5,5
7,5
10
12,5
15
17,5 (20)
20
20
25
25
30
30
35 (40)
35 (40)
40
40
40

2900 rpm

m /h

18

24

30

33

36

39

42

45

48

51

l/min

300

400

500

550

600

650

700

750

800

27 25,5 23,5 22,5 21,5


32
38 35,5 34
40
43
45
47
53,5 51
67 63,5 59 56,5 53,5
64
68
71
80,5 76
75
89 82,5 79
94
107 101 94,5 90,5 85,5
96
120 114 106 102
134 127 118 113 107
147 140 130 124 118
161 152 141 135 128
174 165 153 147 139
187 178 165 158 150
201 190 177 169 160
214 203 189 181 171
228 216 200 192 182
241 228 212 203 192

20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180

18,5
28
37
46,5
56
65
74,5
84
93
102
111
121
130
139
149
158
167

17
25,5
34
42,5
51
59,5
68
76,5
85
93,5
102
110
119
127
136
144
153

15,5
23
31
38,5
46
54
61,5
69
77
85
92,5
100
108
115
123
131
138

H
m

(...) FK motor rated power output

H Total head in m

394

DN

6SDS

B-6SDS

850

mm

kg

kg

14
21
27,5
34,5
41,5
48
55
62
69
76
83
90
96,5
103
110
117
124

584
686
788
890
992
1094
1196
1298
1400
1502
1604
1706
1808
1910
2012
2114
2216

25,5
31,6
36
40,3
47
50,5
55,5
62,5
69
74
79,2
83,2
91,4
96,4
101
106
111

29,5
36,6
42
48,3
59
65,5
66,5
74,5
81
86
94,2
99,2
106
113
119
126
132

G3
ISO 228

Tolerances according to UNI EN ISO 9906:2012

6SDS 58

Submersible borehole pumps for 6 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

U.S. g.p.m. 100

Imp. g.p.m.

150

250

200

100

150

300

200

350

250

300

220
DN

6SDS 58
B-6SDS 58

200

600

CALPEDA

17
16

150

15

ft

14
13

400

12
11
10

100

9
8
7
6

200

3.93.065/1

50

4
14

15

0
m 3/h
Q l/min
0
0

l/s

20

30
500

40

10

- B-6SDS 58/2
- B-6SDS 58/3
- B-6SDS 58/4
- B-6SDS 58/5
- B-6SDS 58/6
- B-6SDS 58/7
- B-6SDS 58/8
- B-6SDS 58/9
- B-6SDS 58/10
- B-6SDS 58/11
- B-6SDS 58/12
- B-6SDS 58/13
- B-6SDS 58/14
- B-6SDS 58/15
- B-6SDS 58/16
- B-6SDS 58/17

P2 Rated motor power output

60
1000
15

70

0
90
1500

80

72.1044

20

25

3~

6SDS 58/2
6SDS 58/3
6SDS 58/4
6SDS 58/5
6SDS 58/6
6SDS 58/7
6SDS 58/8
6SDS 58/9
6SDS 58/10
6SDS 58/11
6SDS 58/12
6SDS 58/13
6SDS 58/14
6SDS 58/15
6SDS 58/16
6SDS 58/17

50

P2

kW

HP

4
5,5
7,5
9,2
11
13 (15)
15
18,5
18,5
22
22
26 (30)
26 (30)
30
30
30

5,5
7,5
10
12,5
15
17,5 (20)
20
25
25
30
30
35 (40)
35 (40)
40
40
40

2900 rpm

m3/h

27

35

40

45

50

55

l/min

450

583

666

750

833

916 1000 1083 1166 1250 1333

mm

kg

kg

21
32
42,5
53
63,5
74
85
95,5
106
117
127
138
148
159
170
180

20
30
39,5
49,5
59,5
59,5
79
89
99
109
119
129
139
148
158
168

19
28,5
38
47,5
57
66,5
76
85,5
95
104
114
123
133
142
152
162

18
27
36
45
54
63
72
81
90
99
108
117
126
135
144
153

17 16,5 15,5 14 12,5 11


9
21 18,5 16 13,5
26 24,5 23
25 21,5 18
28
31
34,5 33
27 22,5
31
41 38,5 35
43
37 32,5 27
42
46
51,5 49
49 43,5 38 31,5
60 57,5 54
56 49,5 43
62
66
69
36
49 40,5
56
77,5 74 69,5 63
54
62
70
77
82
86
45
68 59,5 49,5
77
85
94,5 90
103 100 94,5 86,5 76,5 66,5 55,5
91 80,5 70 58,5
112 107 100
87 75,5 63
98
120 115 108
81 67,5
93
129 123 115 105
99 86,5 72
138 131 123 112
92 76,5
146 139 131 119 105

584
686
788
890
992
1094
1196
1298
1400
1502
1604
1706
1808
1910
2012
2114

26,5
31,6
37
43,3
48
53,5
59,5
65
71
76,2
82,2
87,4
93,4
99,4
104
110

29,5
36,6
43
50,3
57
63,5
70,5
77
84
90,2
97,2
104
111
118
124
131

H
m

(...) FK motor rated power output

H Total head in m

395

60

65

70

75

80

DN

G4
ISO 228

6SDS

Tolerances according to UNI EN ISO 9906:2012

B-6SDS

44

8SDS 70

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


50
50

U.S. g.p.m.

100

Imp. g.p.m.

100

250
200

19

400

300

350

Counter-flange for welding.

8SDS 70
B-8SDS 70

20

350

250

500

400

300

1600
190

18

1400

17

16

ft

15

1200

109
CALPEDA

14

15

13
300

DN

83

40

168

1000

12

11
10

800

9
200

8
.

600
7
6
3.93.066.N

400

100

19

19

200

2
1
0

0
0

m 3/h 20
l/min
l/s

40

60
1000

500

10

15

P2 Rated motor power output

25

72.972

P2
m /h
kW

HP

5,5
9,2
15
18,5
22
26 (30)
30
37
45
45
51 (55)
55
59 (75)
59 (75)
66 (75)
75
75
92
92
92

7,5
12,5
20
25
30
35 (40)
40
50
60
60
70 (75)
75
80 (100)
80 (100)
90 (100)
100
100
125
125
125

1500
20

- B-8SDS 70/1
- B-8SDS 70/2
- B-8SDS 70/3
- B-8SDS 70/4
- B-8SDS 70/5
- B-8SDS 70/6
- B-8SDS 70/7
- B-8SDS 70/8
- B-8SDS 70/9
- B-8SDS 70/10
- B-8SDS 70/11
- B-8SDS 70/12
- B-8SDS 70/13
- B-8SDS 70/14
- B-8SDS 70/15
- B-8SDS 70/16
- B-8SDS 70/17
- B-8SDS 70/18
- B-8SDS 70/19
- B-8SDS 70/20

100

3~

8SDS 70/1
8SDS 70/2
8SDS 70/3
8SDS 70/4
8SDS 70/5
8SDS 70/6
8SDS 70/7
8SDS 70/8
8SDS 70/9
8SDS 70/10
8SDS 70/11
8SDS 70/12
8SDS 70/13
8SDS 70/14
8SDS 70/15
8SDS 70/16
8SDS 70/17
8SDS 70/18
8SDS 70/19
8SDS 70/20

80

15

20

30

40

2900 rpm
50

60

Motor
70

80

90

l/min

250

333

500

666

833 1000 1166 1333 1500

23,5
47
70,5
94
118
141
165
188
212
235
259
282
306
329
353
376
400
423
447
470

23
46
69
92
115
138
161
184
207
230
253
276
299
322
345
368
391
414
437
460

22
44
66
88
110
132
154
176
198
220
242
264
286
308
330
352
374
396
418
440

20,5
41
61,5
82
102
123
143
164
184
205
225
246
266
287
307
328
348
369
389
410

19
38
57
76
95
114
133
152
171
190
209
228
247
266
285
304
323
342
361
380

(...) FK motor rated power output

17
34
51
68
85
102
119
136
153
170
187
204
221
238
255
272
289
306
323
340

H Total head in m

396

15
30
45
60
75
90
105
120
135
150
165
180
195
210
225
240
255
270
285
300

13
26
39
52
65
78
91
104
117
130
143
156
169
182
195
208
221
234
247
260

10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200

DN

f
CS-R
mm

FK
mm

145
6

137
6

191
8

196
8

100

8SDS B-8SDS

mm

kg

kg

602
734
866
998
1130
1262
1394
1526
1658
1790
1922
2054
2186
2318
2450
2582
2714
2846
2978
3110

38
49
60
71,5
82,5
93,5
105
116
127
138
149
160
171
182
193
205
216
227
238
249

43
55,5
68
80,5
93
106
118
131
143
156
168
181
194
206
219
231
244
256
269
281

Tolerances according to UNI EN ISO 9906:2012

8SDS 100

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

200 U.S. g.p.m.

100

100

200

400

500

Imp. g.p.m.

600

400

500

Counter-flange for welding.

400

8SDS 100
B-8SDS 100

H
m

1200

16

ft

135
.

15
300

DN

190
83

CALPEDA

1000
40

14
13

15

12

168

800

11
10
200

9
600
.

8
7
6
400

3.93.066.1.N

5
100
4
19

19

200

2
1
0

0
0
0

m3/h
l/min
l/s

40

80

60

500

1000

10

100
1500
30

Q
m /h
kW

P2 Rated motor power output

72.970

P2
3

- B-8SDS 100/1
- B-8SDS 100/2
- B-8SDS 100/3
- B-8SDS 100/4
- B-8SDS 100/5
- B-8SDS 100/6
- B-8SDS 100/7
- B-8SDS 100/8
- B-8SDS 100/9
- B-8SDS 100/10
- B-8SDS 100/11
- B-8SDS 100/12
- B-8SDS 100/13
- B-8SDS 100/14
- B-8SDS 100/15
- B-8SDS 100/16

2000

20

3~

8SDS 100/1
8SDS 100/2
8SDS 100/3
8SDS 100/4
8SDS 100/5
8SDS 100/6
8SDS 100/7
8SDS 100/8
8SDS 100/9
8SDS 100/10
8SDS 100/11
8SDS 100/12
8SDS 100/13
8SDS 100/14
8SDS 100/15
8SDS 100/16

0
140

120

HP

7,5
5,5
15
11
25
18,5
30
22
40
30
50
37
60
45
60
45
51 (55) 70 (75)
75
55
66 (75) 90 (100)
66 (75) 90 (100)
100
75
125
92
125
92
125
92

30

40

50

60

2900 rpm
70

80

Motor
90

100

110

125

l/min

500

666

833 1000 1166 1333 1500 1666 1833 2083

21,5
43
64,5
86
107
129
150
172
193
215
236
258
279
301
322
344

21
42
63
84
105
126
147
168
189
210
231
252
273
294
315
336

20,5
41
61,5
82
102
123
143
164
184
205
225
246
266
287
307
328

(...) FK motor rated power output

20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
320

19
38
57
76
95
114
133
152
171
190
209
228
247
266
285
304

18
36
54
72
90
108
126
144
162
180
198
216
234
252
270
288

H Total head in m

397

17
34
51
68
85
102
119
136
153
170
187
204
221
238
255
272

15,5
31
46,5
62
77,5
93
108
124
139
155
170
186
201
217
232
248

14
28
42
56
70
84
98
112
126
140
154
168
182
196
210
224

10,5
21
31,5
42
52,5
63
73,5
84
94,5
105
115
126
136
147
157
168

DN

f
CS-R
mm

FK
mm

145
6

137
6

191
8

196
8

125

8SDS B-8SDS

mm

kg

kg

602
734
866
998
1130
1262
1394
1526
1658
1790
1922
2054
2186
2318
2450
2582

38
49
59
70
81
92
102
113
124
135
145
156
167
177
188
199

43
55
67
79
91
103
115
128
140
152
164
176
188
200
212
224

Tolerances according to UNI EN ISO 9906:2012

44

8SDS 150

Submersible borehole pumps for 8 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

100

U.S. g.p.m.

200

100

200

Imp. g.p.m.

500
400

600

700

500

800

600

Counter-flange for welding.

700

340

8SDS 150
B-8SDS 150

300

1000

DN

190
83
135

ft

CALPEDA

40

15

H
800

14
13

15
168

12

200

11

600

10
9
.

8
7

400

100

3.93.066.1.N

5
4
19

200

19

2
1
0

0
0
0

m3/h 40
l/min

l/s

80

120
2000

1000

10

20

40

P2 Rated motor power output

50

72.971

P2

kW

HP

10
7,5
20
15
30
22
40
30
50
37
60
45
51 (55) 70 (75)
59 (75) 80 (100)
66 (75) 90 (100)
100
75
125
92
125
92
150
110
150
110
150
110

l/min

H
m

3000

30

m3/h

- B-8SDS 150/1
- B-8SDS 150/2
- B-8SDS 150/3
- B-8SDS 150/4
- B-8SDS 150/5
- B-8SDS 150/6
- B-8SDS 150/7
- B-8SDS 150/8
- B-8SDS 150/9
- B-8SDS 150/10
- B-8SDS 150/11
- B-8SDS 150/12
- B-8SDS 150/13
- B-8SDS 150/14
- B-8SDS 150/15

200

3~

8SDS 150/1
8SDS 150/2
8SDS 150/3
8SDS 150/4
8SDS 150/5
8SDS 150/6
8SDS 150/7
8SDS 150/8
8SDS 150/9
8SDS 150/10
8SDS 150/11
8SDS 150/12
8SDS 150/13
8SDS 150/14
8SDS 150/15

160

60

70

80

90

2900 rpm

100

110

125

Motor
140

150

160

180

DN

1000 1166 1333 1500 1666 1833 2083 2333 2500 2666 3000
18
36
54
72
90
108
126
144
162
180
198
216
234
252
270

17,5
35
52,5
70
87,5
105
122
140
157
175
192
210
227
245
262

(...) FK motor rated power output

17
34
51
68
85
102
119
136
153
170
187
204
221
238
255

16,5
33
49,5
66
82,5
99
115
132
148
165
181
198
214
231
247

16
32
48
64
80
96
112
128
144
160
176
192
208
224
240

15,5
31
46,5
62
77,5
93
108
124
139
155
170
186
201
217
232

14,5
29
43,5
58
72,5
87
101
116
130
145
159
174
188
203
217

H Total head in m

398

13
26
39
52
65
78
91
104
117
130
143
156
169
182
195

11,5
23
34,5
46
57,5
69
80,5
92
103
115
126
138
149
161
172

10,5
21
31,5
42
52,5
63
73,5
84
94,5
105
115
126
136
147
157

5,5
11
16,5
22
27,5
33
38,5
44
49,5
55
60,5
66
71,5
77
82,5

f
CS-R
mm

145
6

FK
mm

137
6

125
191
8

240
10

196
8

mm

8SDS B-8SDS
kg

38
602
49
734
60
866
998 71,5
1130 82,5
1262 93,5
1394 105
1526 116
1658 127
1790 138
1922 149
2054 160
2186 171
2318 182
2450 193

Tolerances according to UNI EN ISO 9906:2012

kg
43
55,5
68
80,5
93
106
118
131
143
156
168
181
194
206
219

10SDS 160

Submersible borehole pumps for 10 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

100

U.S. g.p.m.

200

500

200 Imp. g.p.m.

100

600

400

700

500

800

600

Counter-flange for welding.

700

400

10SDS 160
B-10SDS 160

H
m

1200
DN

235
107

ft

179

8
1000

300

CALPEDA

7
15
210

800

200

600
4

400

3.93.067.N

100
2
25

26

200
1

m3/h

0
0

Q l/min

l/s

40

80

120
2000

1000
10

20

30

40

m /h

P2 Rated motor power output

50

72.334.1

P2
3

- B-10SDS 160/1
- B-10SDS 160/2
- B-10SDS 160/3
- B-10SDS 160/4
- B-10SDS 160/5
- B-10SDS 160/6
- B-10SDS 160/7
- B-10SDS 160/8
- B-10SDS 160/9

3000

3~

10SDS 160/1
10SDS 160/2
10SDS 160/3
10SDS 160/4
10SDS 160/5
10SDS 160/6
10SDS 160/7
10SDS 160/8
10SDS 160/9

0
200

160

kW

HP

18,5
37
55
75
92
110
130
150
185

25
50
75
100
125
150
175
200
250

l/min

H
m

80

90

100

110

125

2900 rpm
140

150

Motor
160

170

180

190

DN

1333 1500 1666 1833 2083 2333 2500 2666 2833 3000 3166
39,5 38 37,5 36 34,5 32,5 31
29 26,5 22
78,5 76,5 74,5 72,5 69
65
62 58,5 53,5 44
118 114 112 108 104
98 92,5 87,5 80 66,5
157 153 149 145 138 130 123 117 107 88,5
196 191 186 181 173 163 154 146 134 111
236 229 224 217 207 195 185 175 160 133
275 267 261 253 242 228 216 204 187 155
314 305 298 289 276 260 246 233 213 177
356 342 338 324 311 293 279 261 239 198

(...) FK motor rated power output

H Total head in m

399

20
40
60
80
100
120
140
160
180

f
CS-R FK
mm mm
145
6

175

191
8

137
6

196
8

240
10
-

10SDS B-10SDS

mm

kg

kg

865
1035
1205
1375
1545
1715
1885
2055
2225

77
103
126
150
173
197
220
244
268

87
114
141
169
195
222
249
276
303

Tolerances according to UNI EN ISO 9906:2012

44

10SDS 190

Submersible borehole pumps for 10 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

200

U.S. g.p.m.

400

200

400

800

1000

Imp. g.p.m.

1200

800

Counter-flange for welding.

1000

300

10SDS 190
B-10SDS 190

H
m

H
ft

DN

235
107

250

800

179

CALPEDA

200
15
210

5
600

150

400

3
100

3.93.067.N

2
200
25

50

26

m3/h 50
1000

0
0

Q l/min

l/s

100

200

150
2000

20

3000
40

60

m /h

P2 Rated motor power output

kW

HP

22
45
66 (75)
92
110
130
185

30
60
90 (100)
125
150
175
250

l/min

H
m

80

P2
3

- B-10SDS 190/1
- B-10SDS 190/2
- B-10SDS 190/3
- B-10SDS 190/4
- B-10SDS 190/5
- B-10SDS 190/6
- B-10SDS 190/7

72.336.1N

3~

10SDS 190/1
10SDS 190/2
10SDS 190/3
10SDS 190/4
10SDS 190/5
10SDS 190/6
10SDS 190/7

0
300
5000

250
4000

100

120

140

160

2900 rpm

180

200

220

Motor
230

240

250

DN

1666 2000 2333 2666 3000 3333 3666 3833 4000 4166
38
76
115
153
191
229
267

(...) FK motor rated power output

37
73
110
147
183
220
257

35
70
105
140
175
210
244

33
66
98
131
164
197
230

30
61
91
121
152
182
212

27
55
82
109
137
164
191

H Total head in m

400

24
47
71
95
119
142
166

22
44
65
87
109
131
152

20
40
59
79
99
119
139

18
36
53
71
89
107
125

175

f
CS-R
mm

FK
mm

145
6

137
6

191
8
240
10

196
8
-

10SDS B-10SDS

mm

kg

kg

865
1035
1205
1375
1545
1715
1885

78
102
127
151
175
199
223

88
115
143
170
198
225
252

Tolerances according to UNI EN ISO 9906:2012

10SDS 280

Submersible borehole pumps for 10 wells

Characteristic curves, performance n 2900 rpm, dimensions and weights


0

200

400

200

U.S. g.p.m.800

400

1000

Imp. g.p.m.

800

1200

1400

1000

1600
Counter-flange for welding.

1200

200

10SDS 280
B-10SDS 280

600
DN

235
107
179

150

CALPEDA

ft

15
210

H
m

400

100
3

200

3.93.067.N

50
25

m3/h

0
0

Q l/min

l/s

150
100
200
2000
3000
20

40

250
4000
60

350
6000

300
5000
80

100

26

0
400

72.1149.1C

44
Q

3~

m3/h

10SDS 280/1
10SDS 280/2
10SDS 280/3
10SDS 280/4
10SDS 280/5
10SDS 280/6

- B-10SDS 280/1
- B-10SDS 280/2
- B-10SDS 280/3
- B-10SDS 280/4
- B-10SDS 280/5
- B-10SDS 280/6

P2 Rated motor power output

P2

kW

HP

26 (30)
55
75
110
130
150

35 (40)
75
100
150
175
200

l/min

H
m

150

180

200

220

2900 rpm

240

260

280

Motor
300

315

350

2500 3000 3333 3666 4000 4333 4666 5000 5250 5833
29
59
88
118
147
176

(...) FK motor rated power output

28
55
83
111
139
167

27
53
80
106
133
160

26
51
77
103
129
155

25
50
75
100
125
150

24
48
71
95
119
143

H Total head in m

401

23
46
69
92
115
138

21
42
64
85
106
127

20
40
60
80
100
120

16
31
47
63
79
95

DN

f
CS-R FK
mm mm

145-6 137-6
191
8
175
196
8
240
10

10SDS B-10SDS

mm

kg

kg

865
1035
1205
1375
1545
1715

78
103
127
151
175
199

88
116
143
170
198
226

Tolerances according to UNI EN ISO 9906:2012

SD, SDS

Submersible pumps

Cables connection kit


It allows connection of electric cables with junction submerged in water.
The kit includes:
- 4 connectors
- 4 shrink-sheaths for protection of individual wires
- 1 shrink-sheath for protection of the 4-pole wire.
The sheath shrinks with heating (flame or drier) which causes resin outlet granting connection waterproofing.

Installation examples
12/13

16

11

10
7

Hd

Hd

Hs

Hs

Hs

3.93.1O8/1

Hd

14

3.93.108/2

1 Submersible pump
2 Pump support system
3 Electric control board
4 Circuit breaker
5 Minimum level probes
6 Pressure gauge
7 Check valve
8 Throttle gate valve
9 Pressure switch
10 Pressure tank
11 Probes for air entry control
12 Electric valve
13 Compressor
14 Membrane tank
15 Storage tank
16 Start-stop probes

Hs Static level
Hd Dynamic level
P Tubewell depth

402

3.93.108/3

15

09/2016

CS, CS-R, FK

Submersible motors
The Calpeda 4, 6, 8 and 10" submersible motors are built
using advanced technology and components of superior quality that they ensure good mechanical strength and excellent
electrical reliability.
The good performances are guaranteed thanks to strict tests
of all the different components during the various production
phases.

Rewindable motor CS, CS-R series


The CS-R 6/8/10" motors are in a water bath with the wire
being coated with polyvinyl chloride, while the CS 4 motors
have a special food grade dielectric fluid that gives a better
lubricant effect, increasing the life of all moving parts and the
copper wires.
The special design of all our motors allows easy access to the
various components, simplifying maintenance and repair.
All the CS,CS-R motors can be rewound and they are NEMA
STANDARD.
CS, CS-R: Standard construction.
I-CS, I-CS-R: AISI 316 construction.

Encapsulated motor FK series


The FK motors, manufactured to ISO 9001 standards feature
an hermetically sealed stator, where the self healing stator
resin prevents motor burn out.
They are designed for high electrical efficiency, low cost, and
non contaminating water-filled design.
Water lubricated thrust and radial bearings allow a maintenance free operation. A special diaphragm ensures pressure compensation inside the motor.
For facilitating the connection, removable Water Bloc lead
connector is used and for increasing the performance in sand
the FK 6/8 have a sand fighter with SiC-Mechanical Seal.
FK: Standard construction.
I-FK: AISI 316 construction.

kW
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2
11
13
15
18,5
22
26
30
37
45
51
55
59
66
75
85
92
110
130
150
185

CS

8" 3 ~

6" 3 ~

4" 3 ~

4" 1 ~
FK

CS

FK

I-FK
316

CS-R I-CS-R FK
316

I-FK
316

CS-R I-CS-R FK
316

10" 3 ~
I-FK
316








CS

I-CS
316

kW
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
9,2
11
13
15
18,5
22
26
30
37
45
51
55
59
66
75
85
92
110
130
150
185
4.93.325

Rewindable motor CS, CS-R series

Encapsulated motor FK series


403

45

CS, CS-R, FK

Submersible motors

Rewindable motor CS, CS-R series

Encapsulated motor FK series

Operating conditions
Motor

4CS
6CS-R

8CS-R

10CS

P2
all types
411 kW
1315 kW
18,5 kW
2230 kW
37 kW
45 kW
3045 kW
5175 kW
92 kW
all types

Operating conditions

Max.
Liquid
temperature
35 C
30 C
30 C
25 C
25 C
40 C
40 C
25 C
25 C
25 C
25 C

Cooling
minimum
flow velocity
0,08 m/s
0,1 m/s
0,2 m/s
0,2 m/s
0,2 m/s
0,1 m/s
0,3 m/s
0,3 m/s
0,3 m/s
0,3 m/s
0,50 m/s

Motor

Max.
starts
per hour
20
15
15
15
13
13
6
10
8
6
10

4FK
6FK
8FK

Section
3x1,5 + 1G1,5
3x1,5 + 1G1,5
3 x (1x2,5)
3 x (1x4)
3 x (1x6)
3 x (1x10)
3 x (1x16)
3 x (1x25)
4G25
4G35

Length
2
m
3
m
3,5 m
3,5 m
3,5 m
3,5 m
4
m
4
m
6
m
6
m

Motor 400/690V - 50Hz - 3 ~ Y/


10CS 150
kW
10CS 185
kW

mm2
mm2
mm2
mm2
mm2
mm2
mm2
mm2
mm2
mm2

Section
3x25 + 4G25 mm2
3x35 + 4G35 mm2

Components
External frame
Motor flange
Shaft end
Thrust bearing
Bushings

Section
3x1,5 + 1G1,5 mm2

Length
1,5 m

Motor 400V - 50Hz


4FK 0,37 1,5
4FK 2,2 5,5
6FK 4 22
6FK 30 - 45

Section
3x1,5 + 1G1,5
3x1,5 + 1G1,5
4G4
3x8,4 + 1G8,4
3x8,4 + 1G8,4
3 x (1x16)
3 x (1x35)

Length
1,5 m
2,5 m
4 m
4 m

-3~
kW
kW
kW
kW
kW
kW
kW

mm2
mm2
mm2
mm2
mm2
mm2
mm2

8
8
8

m
m
m

Materiales
Components
External frame
Motor flange
Shaft end
Thrust bearing

Length
6 m
6 m

Components
External frame
Supports
Shaft end

4
Cr-Ni steel AISI 304
Cr-Ni-Mo steel AISI 316L
Cr-Ni-Mo steel AISI 316

Thrust bearing

Oil wetted
6, 8, 10 standard

Motor 230V - 50Hz - 1~


4FK 0,37 2,2
kW

8FK 30 45
8FK 55 93
8FK 110 150

Materiales
Components
External frame
Motor flange
Shaft end
Thrust bearing

20

Cable

Cable

Motor 400V - 50Hz - 3 ~


4CS 0,37 1,5 kW
4CS 2,2 5,5 kW
6CS-R 4 11
kW
6CS-R 13 22 kW
6CS-R 26 - 30 kW
6CS-R 37 - 45 kW
8CS-R 30 45 kW
8CS-R 51 - 92 kW
10CS 85
kW
10CS 110-130
kW

0,16 m/s

2-pole induction motor, 50 Hz (n 2900 rpm).


Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- single-phase 230 V - up to 2,2 kW for 4 motors.
- three-phase 230 V; 400 V for 4 motors.
- three-phase
400 V; 400/690 V for 6-8 motors.
Voltage tolerance : +6% / -10%.
In order to limit both current and torque at each starting, for rated motor
powers equal to or higher than 7.5kW, one of the following types of starting is necessary: star/delta, soft starter, stator impedance or autotransformer.
Insulation class B for 4 motors, class F for 6-8 motors.
Protection IP 68.
Motor suitable operation with frequency converter.

2-pole induction motor, 50 Hz (n 2900 rpm).


Sized for connection to the pumps according to NEMA Standards.
Standard voltages:
- single-phase 230 V - up to 2,2 kW for 4 motors.
- three-phase 230 V; (5,5 kW excluded) 400 V for 4 motors.
- three-phase 400 V; 400/690 V for 6-8-10 motors.
Voltage tolerance : +6% / -10%.
In order to limit both current and torque at each starting, for rated motor
powers equal to or higher than 7.5kW, one of the following types of starting
is necessary: star/delta, soft starter, stator impedance or autotransformer.
Insulation class F for 4 motors, class E for 6-8 motors, PVC coated
wire for 10 motors.
Motor suitable operation with frequency converter (4 single-phase excluded).
Protection IP 68.

Length
2 m
2 m

Max. starts
per hour
20
20

Operation data

Operation data

Section
3x1,5 + 1G1,5 mm2
3x2 + 1G2 mm2

Cooling
minimum flow velocity
0,08 m/s
0,16 m/s

Continuous duty.

Continuous duty.

Motor 230V - 50Hz - 1~


4CS 0,37 1,5 kW
4CS
2,2
kW

Max. Liquid
temperature
30 C
30 C for 4 30 kW
50 C for 37 45 kW
30 C

4 standard

4 AISI 316

Cr-Ni steel AISI 304


Cr-Ni steel AISI 304
Cr-Ni steel AISI 303
Oscillating pads

Cr-Ni-Mo steel AISI 316Ti


Cr-Ni-Mo steel AISI 316L
Cr-Ni-Mo steel AISI 329
Oscillating pads

6, 8 standard

6, 8 AISI 316

Cr-Ni steel AISI 304


Cast iron GJL 200 EN 1561
Cr-Ni steel AISI 304
(AISI 303 for 8)
Oscillating pads

Cr-Ni-Mo steel AISI 316 Ti


Cr-Ni-Mo steel AISI 316
Cr-Ni-Mo steel AISI 316
(AISI 630 for 8)
Oscillating pads

6, 8, 10 AISI 316

AISI 304 (AISI 316Ti for 10)


Cr-Ni-Mo steel AISI 316
Cast iron GJL 200 EN 1561
Cr-Ni-Mo steel AISI 316
Cr-Ni steel AISI 431
AISI 316 (AISI 630 from 30 to 93kW)
(AISI 329 for 10)
(AISI 429 for 10)
Oscillating pads
Oscillating pads
Graphite (Bronze for 8)
Graphite (Bronze for 8)

Special features on request


- Other voltage.
- Frequency 60 Hz.
- Higher liquid temperature.

Special features on request


- Other voltage. - Frequency 60 Hz.
- Higher liquid temperature.

404

CS, CS-R

Submersible motors

Performance, dimensions and weights

4"CS - 1 ~
HP
0,5

4CS 0,55M

0,55

0,75

4.0

0.99

0.97

0.89

62

54

35

4CS 0,75M

0,75

5.6

0.98

0.99

0.99

62

55

36

4CS 1,1M

1,1

1,5

8.4

0.97

0.93

0.83

61

55

36

4CS 1,5M

1,5

11.2

0.99

0.97

0.89

64

59

4CS 2,2M

2,2

14.7

0.96

0.93

0.80

67

64

Power factor
cos
4/4
3/4
2/4
0.85
0.96 0.93

Efficiency
%
4/4
3/4
2/4
29
46
53

Direct start Capacitor Axial


thrust
IA
CA 450 Vc
N
F
IN
CN
16
3.8 0.78

R.P.M.

Weight

mm

kg

327
362
402
447
467
517

7,6
9,4
10,7
12,4
13,5
15,7

Axial thrust

Weight

mm

kg

327
347
362
402
447
402
481
546
646

7,7
8,7
9,9
10,8
12,6
11,7
14,9
18,2
23

4.6

0.80

25

4.2

0.81

35

4.2

0.81

40

39

3.9

0.75

60

44

4.2

0.51

70

2850

1500

Connection

4" NEMA

38

4CS 0,37M

kW
0,37

IN
230 V
A
3.2

PN

Type

4"CS - 3 ~
IN
400 V
A

PN

Type

Power factor
cos
4/4
3/4
2/4

Direct start

Efficiency
%
4/4
3/4
2/4

IA
IN

CA
CN

4CS 0,37T

kW
0,37

HP
0,5

1.2

0.72

0.64

0.47

63

58

44

5.6

4.2

4CS 0,55T

0,55

0,75

1.5

0.79

0.71

0.53

68

66

52

6.1

4.10

4CS 0,75T

0,75

2.0

0.77

0.69

0.48

74

71

58

5.7

4.02

4CS 1,1T

1,1

1,5

2.9

0.78

0.69

0.48

75

73

60

5.7

3.95

4CS 1,5T

1,5

4.2

0.73

0.64

0.44

72

70

55

5.9

4.58

4CS 2,2T

2,2

5.5

0.81

0.71

0.47

72

73

62

4.9

2.2

7,4

0,81

0,72

0,56

73,5

73,5

69

5,7

2,16

5,5

9,4

0,82

0,74

0,60

74,5

75

71

6,3

2,19

5,5

7,5

13

0,81

0,72

0,57

76

76

71

7,8

3,44

4CS 3T
4CS 4T
4CS 5,5T

R.P.M.

2850

1500

4500

96

6"CS-R, I-6"CS-R
IN

PN

Type

Power factor
cos

Direct start

Efficiency
%

Axial thrust

Weight

mm
530

kg
30,5

Standard
6CS-R 4

AISI 316
I-6CS-R 4

kW
4

HP
5,5

400 V
A
11

2825

1,5

N
30000

6CS-R 5,5

I-6CS-R 5,5

5,5

7,5

14,5

0,81

0,72

72

72

2815

3,2

1,5

30000

550

33

6CS-R 7,5

I-6CS-R 7,5

7,5

10

18,5

0,80

0,72

76

76

2830

4,1

30000

595

38

6CS-R 9,2

I-6CS-R 9,2

9,2

12,5

22

0,80

0,71

78

78

2840

1,7

30000

640

41,7

6CS-R 11

I-6CS-R 11

11

15

26

0,83

0,76

78

79

2835

5,2

2,5

30000

670

44,4

6CS-R 13

I-6CS-R 13

13

17,5

31

0,80

0,69

79

78

2840

2,6

30000

700

47,7

6CS-R 15

I-6CS-R 15

15

20

35

0,80

0,72

81

81

2855

1,95

30000

715

52

25

42

0,82

0,74

81

82

2840

5,4

2,5

30000

750

56

790

59,8

6CS-R 18,5 I-6CS-R 18,5 18,5

4/4
0,80

3/4
0,70

4/4
70

3/4
68

R.P.M.

IA
IN

CA
CN

6CS-R 22

I-6CS-R 22

22

30

49,5

0,83

0,76

81

83

2820

4,5

1,7

30000

6CS-R 26

I-6CS-R 26

26

35

57,5

0,82

0,74

83

84

2850

5,3

30000

875

70

6CS-R 30

I-6CS-R 30

30

40

64,6

0,80

0,74

85

87

2845

5,3

30000

1025

85,7

6CS-R 37

I-6CS-R 37

37

50

82,5

0,80

0,72

86

87

2870

2,4

30000

1227

111

6CS-R 45

I-6CS-R 45

45

60

98,9

0,80

0,73

85

85

2860

5,1

30000

1287

119

Connection

6" NEMA
73

143

Connection

8" NEMA

8"CS-R, I-8"CS-R
IN

PN

Type

Power factor
cos

Direct start

Efficiency
%

Standard

AISI 316

kW

HP

8CS-R 30

I-8CS-R 30

30

40

400 V
A
63

8CS-R 37

I-8CS-R 37

37

50

81,5

0,82

0,77

85

86

8CS-R 45

I-8CS-R 45

45

60

91

0,84

0,79

86

86

8CS-R 51

I-8CS-R 51

51

70

104

0,84

0,81

86

8CS-R 59

I-8CS-R 59

59

80

119

0,84

0,81

8CS-R 66

I-8CS-R 66

66

90

133

0,83

0,81

8CS-R 75

I-8CS-R 75

75

100

147

0,85

8CS-R 92

I-8CS-R 92

92

125

181

0,84

Axial thrust

Weight

IA
IN

CA
CN

mm

kg

5,5

1,8

60000

1039

143

2905

5,9

1,8

60000

1094

155

2905

5,85

1,9

60000

1174

171,5

87

2905

1,9

60000

1269

192

87

87

2910

6,2

60000

1374

210

88

88

2905

6,1

60000

1409

219

0,83

88

88

2895

5,9

60000

1479

234,5

0,81

88

88

2905

6,3

2,1

60000

1664

264,5

4/4
0,85

3/4
0,82

4/4
83

3/4
84

R.P.M.

2900

101,5

191

Connection

PN

Type
Standard

AISI 316

Direct start

IN
400 V
A

4/4

3/4

2/4

4/4

3/4

2/4

174

0,85

0,81

0,72

85

85

83

Power factor
cos

Efficiency
%
R.P.M.

Axial thrust

Weight

IA
IN

CA
CN

4,7

1,1

mm
1419

kg
280

kW
85

HP
115

I-10CS 110

110

150

232

0,82

0,76

0,65

86

86

84

1,3

1529

315

I-10CS 130

130

175

256

0,86

0,82

0,74

88

88

87

5,3

1,3

1656

362

10CS 150

I-10CS 150

150

200

298

0,85

0,81

0,73

87

88

86

5,3

1,3

1769

413

10CS 185

I-10CS 185

185

250

384

0,81

0,75

0,64

88

88

86

5,6

1,7

1919

449

10CS 85

I-10CS 85

10CS 110
10CS 130

PN Rated power output

IN Rated current

2900

IA Starting current / Nominal current


IN

405

CA
CN

60000

Starting torque/Nominal torque

101,5

8" NEMA

10"CS, I-10"CS

M
235

45

FK, I-FK

Submersible motors

Performance, dimensions and weights

4FK - 1 ~
kW
0,37

HP
0,5

4FK 0,55M

0,55

0,75

4,3

0,94

0,91

0,86

63

4FK 0,75M

0,75

5,7

0,98

0,96

0,92

59

4FK 1,1M

1,1

1,5

8,4

0,92

0,86

0,77

4FK 1,5M

1,5

10,7

0,95

0,90

4FK 2,2M

2,2

14,7

0,97

0,93

Direct start

2/4
35

R.P.M.

IA
IN

2860

3,8

Capac.
450 Vc
F
16
0,94

57

45

2850

4,1

0,86

20

52

41

2845

35

63

56

43

2845

0,84

40

0,82

66

59

48

2830

3,9

0,76

50

0,86

68

62

51

2840

4,2

0,74

70

CA
CN

Power factor
cos
4/4
3/4
2/4
0,78
0,91 0,85

Efficiency
%
4/4
3/4
46
54

CA
CN

Axial
thrust
N

3000

Weight

mm
228

kg
8

253

9,2

282

10,4

Connection

307

11,8

4" NEMA

339

12,9

4000

437

17,3

Axial thrust

Weight

38

4FK 0,37M

IN
230 V
A
3,3

PN

Type

I-4FK, 4FK - 3 ~
PN

I-4FK, 4FK 0,37T


I-4FK, 4FK 0,55T
I-4FK, 4FK 0,75T
I-4FK, 4FK 1,1T
I-4FK, 4FK 1,5T
I-4FK, 4FK 2,2T
I-4FK, 4FK 3T
I-4FK, 4FK 3,7T
I-4FK, 4FK 4T
I-4FK, 4FK 5,5T
I-4FK, 4FK 7,5T

Power factor
cos

Direct start

Efficiency
%

kW
0,37

HP
0,5

IN
400 V
A
1,1

0,55

0,75

1,6

0,74

0,65

0,53

68

63

55

2845

Type

4/4
0,74

3/4
0,66

2/4
0,55

4/4
66

3/4
63

2/4
54

R.P.M.

IA
IN

2855

4,92

2,5

mm
214

kg
7,2

4,63

2,31

228

7,7

0,75

0,77

0,68

0,55

70

68

61

2865

3,5

2,69

1,1

1,5

2,8

0,78

0,69

0,57

74

72

66

2850

5,71

3,09

1,5

3,9

0,78

0,68

0,55

73

71

65

2855

5,31

2,2

5,5

0,77

0,66

0,52

75

74

69

2845

5,42

7,5

0,77

0,67

0,53

76

76

70

2845

3,7

0,78

0,69

0,54

78

77

73

5,5

9,9

0,77

0,67

0,52

78

77

5,5

7,5

12,6

0,81

0,73

0,59

79

7,5

10

17,1

0,81

0,72

0,58

79

248

8,7

283

10,2

2,82

307

11,2

2,99

339

12,6

5,6

3,17

394

15

2840

5,81

3,32

520

19,1

72

2840

5,76

3,28

543

20

79

75

2865

6,13

3,09

653

26,6

79

75

2855

5,81

2,91

731

30,6

3000

6500

95,5

Connection

I-6FK, 6FK - 3 ~
kW
4
5,5
7,5
9,2
11
15
18,5
22
30
37
45

HP
5,5
7,5
10
12,5
15
20
25
30
40
50
60

Power factor
cos

4/4
0,82
0,82
0,86
0,80
0,85
0,85
0,85
0,86
0,84
0,85
0,84

3/4
0,74
0,75
0,81
0,72
0,79
0,80
0,79
0,81
0,79
0,80
0,80

2/4
0,62
0,63
0,70
0,58
0,68
0,70
0,68
0,71
0,67
0,70
0,70

Direct start

Efficiency
%

4/4
78
79
79
81
81
81
82
83
83
81
82

3/4
77
78
78
81
81
81
82
83
83
81
82

2/4
74
74
75
78
78
79
80
81
80
78
80

R.P.M.

IA
IN

CA
CN

2860
2870
2860
2870
2860
2860
2850
2860
2860
2875
2875

4,6
5,1
5,2
5,4
5,5
5,4
6
5,9
6,2
5,2
5,3

1,5
1,9
1,9
2,2
2,1
2,1
2,5
2,4
2,6
2,3
2,2

Axial thrust

Weight

mm
581
615
646
679
711
776
842
907
1037
1421
1574

kg
37,5
41,1
45,2
47,5
50,9
56,7
63,3
69,3
83,9
138
152

15500

27500

1/2" UNF

I-6FK, 6FK 4
I-6FK, 6FK 5,5
I-6FK, 6FK 7,5
I-6FK, 6FK 9,2
I-6FK, 6FK 11
I-6FK, 6FK 15
I-6FK, 6FK 18,5
I-6FK, 6FK 22
I-6FK, 6FK 30
I-6FK, 6FK 37
I-6FK, 6FK 45

IN
400 V
A
9,3
12,5
16
20,7
23,3
31,3
38,5
45,3
63,5
79
95,2

73

PN

Type

6" NEMA

137

Connection

I-8FK, 8FK - 3 ~
kW
30
37
45
55
75
92
110
130
150

PN Rated power output

HP
40
50
60
75
100
125
150
175
200

Power factor
cos

4/4
0,84
0,86
0,85
0,87
0,87
0,83
0,84
0,87
0,88

IN Rated current

3/4
0,78
0,81
0,81
0,82
0,82
0,78
0,80
0,84
0,86

2/4
0,68
0,71
0,71
0,72
0,72
0,68
0,70
0,79
0,79

Direct start

Axial thrust

Weight

R.P.M.

IA
IN

CA
CN

2900
2920
2920
2920
2925
2930
2930
2920
2920

6,85
7,2
7,25
8
8
7
7,2
6,9
6,54

2,6
2,4
2,7
3,1
2,3
1,9
2,1
2,2
2,1

45000

mm
909
986
1062
1204
1395
1747
1976
2179
2408

kg
116
131
145
175
213
291
334
380
429

Efficiency
%

4/4
86
87
87
88
87
87
88
88
88

3/4
86
87
87
87
87
86
87
87
88

2/4
83
84
85
85
85
84
85
86
86

IA Starting current / Nominal current


IN

406

CA Starting torque/Nominal torque


CN

17,5

I-8FK, 8FK 30
I-8FK, 8FK 37
I-8FK, 8FK 45
I-8FK, 8FK 55
I-8FK, 8FK 75
I-8FK, 8FK 92
I-8FK, 8FK 110
I-8FK, 8FK 130
I-8FK, 8FK 150

IN
400 V
A
61
74
89
108
145
190
222
252
284

101,5

PN

Type

8" NEMA

195,6

CS, CS-R, FK

Submersible motors

Maximum length of electric cables


230 Volt - 50 Hz - 1 ~
IN

1 four-wires cable 4 x ....mm2

2,5

1,5

10

189
142
113
95
81
71
63
57
45
38

231
185
154
132
115
103
92
74
62

cables max m

142
71
47
35
28
24
20
18

2
4
6
8
10
12
14
16
18
20
25
30

235
118
78
59
47
39
34
29
26
24

189
126
94
76
63
54
47
42
38
30
25

Voltage drop 3%.


Maximum ambient temperature + 30 C.

Direct-starting

230 Volt - 50 Hz - 3 ~
IN
A

1 four-wires cable 4 x ....mm2

1,5 2,5

10

16

25

400 Volt - 50 Hz - 3 ~
IN

4 cables 1 x ....mm2

35

50

70

95 120 150

1 four-wires cable 4 x ....mm2

1,5 2,5

10

16

cables max m

2
4
6
8
10
12
14
16
18
20
25
30
35
40
45
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300

164
82
55
41
33
27
23
20

272
136
91
68
54
45
39
34
30
27

218
145
109
87
73
62
55
48
44
35
29

218
164
131
109
94
82
73
65
52
44
37
33

267
213
178
152
133
118
107
85
71
61
53
47
43

239
209
186
167
134
111
95
83
74
67
56
48

257
206
171
147
129
114
103
86
73
64
57
51

233
200
175
155
140
116
100
87
78
70
64
58

25

4 cables 1 x ....mm2

35

50

70

95 120 150 185 240

cables max m

227
202
181
151
130
113
101
91
82
76
70
65
60
57
53
50
48
45

249
207
178
155
138
124
113
104
96
89
83
78
73
69
65
62
57
52

230
201
179
161
146
134
124
115
107
101
95
89
85
81
73
67
62
58
54

241
214
193
175
161
148
138
128
120
113
107
101
96
88
80
74
69
64

224
203
186
172
160
149
140
132
124
118
112
102
93
86
80
75

2
4
6
8
10
12
14
16
18
20
25
30
35
40
45
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300

407

285
143
95
71
57
48
41
36

473
236
158
118
95
79
68
59
53
47

379
253
190
152
126
108
95
84
76
61
51

285
228
190
163
142
127
114
91
76
65
57

309
265
232
206
185
148
124
106
93
82
74

323
290
232
194
166
145
129
116
97
83

358
298
256
224
199
179
149
128
112
99
89

347
304
270
243
203
174
152
135
122
110
101

316
263
225
197
175
158
143
132
121
113
105
99
93
88
83
79

309
270
240
216
197
180
166
155
144
135
127
120
114
108
98
90

311
280
255
233
216
200
187
175
165
156
147
140
127
117
108
100
93

305
279
258
239
223
209
197
186
176
168
152
140
129
120
112

299
278
259
243
229
216
205
195
177
162
150
139
130

302
283
267
252
239
227
206
189
174
162
151

45
297
281
267
243
223
206
191
178

CS, CS-R, FK

Submersible motors

Maximum length of electric cables


Star-delta starting

400 Volt - 50 Hz - 3 ~ Y/

230 Volt - 50 Hz - 3 ~ Y/
IN
A

2 four-wires cables 4 x ....mm2

1,5

2,5

10

16

25

IN

7 cables 1 x ....mm2

35

50

70

95

120 150

2 four-wires cables 4 x ....mm2

1,5

2,5

10

35

50

70

31

50

76

123 193

30

55

88

131 214 335

35

27

43

65

105 165

35

47

75

113 183 287

40

24

38

57

92

144

40

41

66

99

160 251

45

21

34

50

82

128 198

45

58

88

143 223 344

30

45

74

116 178

50

53

79

128 201 310

60

38

62

96

148 201

60

66

107 167 258 350

70

32

53

83

127 173 224

70

56

92

144 221 300

80

46

72

111

151 196

80

80

126 193 263 341

90

41

64

99

134 174

90

71

112 172 234 303

100

58

89

121 157 215

100

64

100 155 210 273 374

58

50

19

25

95

120 150

cables max m

cables max m

30

16

7 cables 1 x ....mm2

33

110

53

81

110 143 196

110

91

141 191 248 340

120

48

74

101 131 179

120

84

129 175 228 312

130

44

68

93

121 166 214

130

77

119 162 210 288 373

140

64

86

112 154 199

140

111

150

59

81

105 143 186

150

103 140 182 249 323

160

56

76

98

134 174 208

160

97

170

52

71

92

127 164 196

170

124 161 220 285 341

180

67

87

120 155 185

180

117 152 208 269 322

190

64

83

113 147 175 204

190

111

78

108 139 167 194

200

137 187 242 290 337

220

98

127 152 176

220

170 220 264 306

240

90

116 139 161

240

156 202 242 280

260

83

107 128 149

260

186 223 259

280

77

100 119 138

280

173 207 240

300

72

93

300

162 193 224

200

111

129

150 195 267 346


131 171 234 303 362

144 197 255 305 354

- Against short-circuits and overloads to the electric pumps system we advise to follow the usually applied normative.
- To avoid a possible dry working of the electric pump in is better to install a level control.
- In order to avoid overheatings, tension grops above 3%, we advise to use suitable starting motors systems.
- All the cable wave to respect the usually applied normative and to present excellent insullation characteristics.

The tables show the maximum length of the cable depending on the current absorbed by the motor and the cross section area of the cable, at different voltages. The maximum voltage drop equal to 3%, cable temperature of 80C, water installation similar to air installation at a temperature of
30C.

408

CS, CS-R, FK

Submersible motors

Choice of electric cable by calculation


For dimensioning the phase cross section area for the submersible motor need the following information:
V: Rated voltage (V)
I: Motor current (A)
L: Length of cable (km)
cos : power factor
Ambient temperature (C)
The choice of the minimum cross section area of the phase conductor is determined by the rated motor current and the values reported in Table 1.
Table 1

Type of cable*
four-wires cable
four-wires cable
four-wires cable
four-wires cable
four-wires cable
four-wires cable
four-wires cable
four-wires cable
single-wire cable
single-wire cable
single-wire cable
single-wire cable
single-wire cable
single-wire cable
single-wire cable

Cable cross
section
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240

Maximum cable current

Resistance

Reactance

1 line
A
18
24
32
41
57
76
96
119
167
216
264
308
356
409
485

R at 80C
ohm/km
15.1
9.08
5.63
3.73
2.27
1.43
0.91
0.65
0.473
0.328
0.236
0.188
0.153
0.123
0.094

X at 60Hz
ohm/km
0,142
0,131
0,121
0,115
0,103
0,098
0,097
0,094
0,121
0,116
0,118
0,113
0,112
0,109
0,110

2 lines
A
15
20
27
35
48
65
82
101
142
184
224
262
303
348
412

* Up to 35 mm2 sections four-wire cable are used, from 50 mm2 single core cables are recommended as well.Tab.1

The maximum current of the cables listed in Table 1 are for ambient temperature of 30 C.
When the temperature is different, the maximum current of the cables should be corrected by a factor given in Table 2.
Table 2
Ambient Temperature C
Correction factor

10

15

20

25

30

35

40

45

50

55

60

1,22

1,17

1,12

1,06

0,94

0,87

0,79

0,71

0,61

0,5

The cross section area of the phase conductor is choosen by checking the voltage drop along the line , through the following equation:
DU% = 1,73*I*L*(R*cos +X*sen )/(V*1000)
DU% the voltage drop should not be greater than 3%
R, X = cable resistance and reactance in ohms/km (indicated in Table 1)
sen = 1-(cos)2
In case of star / delta starting the rated current of the motor should be divided by 1.73.

Determination of minimal sections of the protective conductor PE.


Table 3
Phase cross section area
S
mm2
S 16
16 < S 25
S > 25

PE cross section area


SPE
mm2
S
16
S/2

409

45

CS, CS-R, FK

Submersible motors

Electric control panels


M COMP Control panel for 1 single-phase submersible pump
Protector

Type

LVBT

kW

16
20
20
25
20
35
25
30
25
30
35
40
35
50
60
70

0,37
0,55
0,55
0,55
0,75
0,9
0,9
0,9
1,1
1,1
1,1
1,1
1,5
1,5
1,5
2,2

220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110

Motor
230V - 1~

max A
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M

450Vc

Dimensions
HxBxP
mm

Capacitor

COMP 4-16
COMP 4-20
COMP 5-20
COMP 5-25
COMP 6-20
COMP 6-35
COMP 7-25
COMP 7-30
COMP 8-25
COMP 8-30
COMP 10-35
COMP 10-40
COMP 12-35
COMP 12-50
COMP 12-60
COMP 16-70

4,5
4,5
5
5
6
6
7
7
8
8
10
10
12
12
12
16

F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F

Construction
Control panel with ON-OFF switch and capacitor
for 1 submersible pump with single-phase motor.
Suitable for use with LVBT board for level control.
Protection is provided by means of a main bipolar switch with a phase protected against
overload by means of a thermal element.

PFC-M Control panel for 1 submersible pump with single-phase motor, PF control
Setting

Type

PFC-M
PFC-M
PFC-M
PFC-M
PFC-M
PFC-M
PFC-M
PFC-M
PFC-M

Capacitor

Motor 50/60Hz
220V-240V - 1~

18-16
18-20
18-25
18-30
18-35
18-40
18-50
18-60
18-70

1
1
1
1
1
1
1
1
1

450Vc

kW

16
20
25
30
35
40
50
60
70

0,37
0,55
0,55
0,75
0,75
1,1
1,5
1,5
2,2

18
18
18
18
18
18
18
18
18

F
F
F
F
F
F
F
F
F

Dimensions
HxBxP
mm
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110

Construction
Control panel for controlling one submersible
pump with single-phase motor.
Electronic control of the operation and dryrunning protection through the power factor (PF)
control.
The installation of level probes into the well is
not required.
It stops the pump in case of lack of air cushion in
the pressure vessel (patented system).
Displayed operating data and alarms available in
four languages.

QML 1 FT Control panel for 1 pump with single-phase motor, direct starting

QML 1
QML 1
QML 1
QML 1
QML 1

kW

Dimensions
HxBxP
mm

0,37
0,45 - 0,55
0,75
1,1
1,5

1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12

200x255x170
200x255x170
200x255x170
200x255x170
200x255x170

Motor

Type

Setting

230V - 1~

FT
FT
FT
FT
FT

0,37
0,55
0,75
1,1
1,5

Construction
Control panel for 1 pump with single-phase motor,
direct starting for pressure booster sets, with a
patented working time-measuring system that stops
the pump in case of lack of air cushion in the
pressure vessel.
Arranged for the capacitor internal connection (for
pumps without built-in capacitor) and for the SRL 3
level control card application against dry running.
Pump operation controlled by an electronic
board type MP 1000 with microprocessor which
allows three different modes of operation of the
pump: standard, emergency and timed.

T COMP Control panel for 1 submersible pump with three-phase motor


Type

T
T
T
T
T

COMP 8
COMP 10
COMP 12
COMP 16
COMP 20

Motor

Motor

230V - 3~

400V - 3~

kW

kW

Dimensions
HxBxP
mm

18
7 10
9 12
11 16
14 20

0,37 1,5
--2,2
3
3,7 - 4

0,5 2,2
3 3,7
4
5,5
7,5

170x145x85
230x180x155
230x180x155
230x180x155
230x180x155

Protector

410

Construction
Control panel and protection for 1 submersible
pump with three-phase motor.
Arranged for the LVBT level control internal
connection against dry running (T COMP8 model
has the level control as a standard).
Control pumps with pressure switch and floattype switch.

CS, CS-R, FK

Submersible motors

Electric control panels


PFC-T Control panel for 1 submersible pump with three-phase motor, PF control
Setting

Type

kW

A
PFC-T 11
PFC-T 16

1 - 11
1 - 16

0,37 - 4
5,5

Construction

kW

Dimensions
HxBxP
mm

kg

0,37 - 4
5,5

255x200x135
255x200x135

1,7
1,7

Motor
400V 50Hz - 3~ 380V 60Hz - 3~

Control panel for controlling 1 submersible pump


with three-phase motor. Electronic control of the
operation and dry-running protection through the
power factor (PF) control.
The installation of level probes into the well is not
required.
It stops the pump in case of lack of air cushion in the
pressure vessel (patented system) Displayed operating
data and alarms, available in four languages.

QTL 1 FT Control panel for 1 pump with three-phase motor, direct starting

QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1

Setting

kW

Dimensions
HxBxP
mm

0,37 - 0,45 - 0,55


0,75 - 1,1
1,5
2,2 - 3
4
5,5
7,5
9,2
11

1 - 1,6
1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12
13 - 18
17 - 23
20 - 25

200x255x170
200x255x170
200x255x170
200x255x170
200x255x170
200x255x170
400x300x160
400x300x160
400x300x160

Motor

Type

400V - 3~

FT 0,55
FT 1,1
FT 1,5
FT 3
FT 4
FT 5,5
D 7,5 FT
D 9,2 FT
D 11 FT

Construction
Control panel for 1 pump with three-phase motor,
direct starting for pressure booster sets, with a
patented working time-measuring system that
stops the pump in case of lack of air cushion in
the pressure vessel.
Pump operation controlled by an electronic card
type MP 1000 with microprocessor which allows
three different modes of operation of the pump:
standard, emergency and timed.
Dry-running protection with float switch.
Arranged for SRL 3 level control application for
probes connection against dry-running.

QTL 1 D FTE Control panel for 1 pump with three-phase motor, direct starting

QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1

kW

Dimensions
HxBxP
mm

4
5,5
7,5
9,2
11
15
18,5
22
30

6,3 - 10
9 - 12
13 - 18
17 - 23
20 - 25
24 - 32
32 - 38
35 - 50
46 - 65

400x300x160
400x300x160
400x300x160
400x300x160
400x300x160
500x350x200
500x350x200
500x350x200
500x350x200

Motor

Type

Setting

400V - 3~

D
D
D
D
D
D
D
D
D

4 FTE
5,5 FTE
7,5 FTE
9,2 FTE
11 FTE
15 FTE
18,5 FTE
22 FTE
30 FTE

Construction
Electromechanical control panel for 1 pump with
three-phase motor, direct starting.
Operating signals by E 1000 led card.
Dry-running protection with float switch.
Construction with SRLE level control for probes
connection against dry-running on request .

QTL 1 ST FT Control panel for 1 pump with three-phase motor, Y/ starting


Type
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1

ST
ST
ST
ST
ST
ST
ST
ST
ST
ST

5,5 FT
7,5 FT
11 FT
15 FT
18,5 FT
22 FT
30B FT
30A FT
37 FT
45 FT

Motor 400V - 3~
Current
Power
A
kW

Dimensions
HxBxP
mm

11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105

600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
700x500x200
700x500x200
700x500x200
800x600x250
800x600x250

5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45

411

Construction
Control panel for 1 pump with three-phase motor,
Y/ starting for pressure booster sets, with a
patented working time-measuring system that
stops the pump in case of lack of air cushion in
the pressure vessel.
Pump operation controlled by an electronic card
type MP 1000 with microprocessor wicht 3
different pump operating modes: standard,
emergency and timed.
Dry-running protection with float switch.
Arranged for SRL 3 level control application for
probes connection against dry-running on request.

45

CS, CS-R, FK

Submersible motors

Electric control panels


QTL 1 ST FTE Control panel for 1 pump with three-phase motor, Y/ starting
Type
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1

ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST

5,5 FTE
7,5 FTE
11 FTE
15 FTE
18,5 FTE
22 FTE
30B FTE
30A FTE
37 FTE
45 FTE
55 FTE
75 FTE
92 FTE
110 FTE

Motor 400V - 3~
Power
Current
kW
A

Dimensions
HxBxP
mm

5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75
92
110

500x350x200
500x350x200
500x350x200
500x350x200
500x350x200
600x400x200
600x400x200
600x400x200
700x500x200
700x500x200
700x500x200
800x600x250
800x600x250
800x600x250

11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105
100 - 125
120 - 160
140 - 198
180 - 250

Construction
Electromechanical control panel for 1 pump with
three-phase motor, Y/ starting.
Operating signals by E 1000 led board.
Dry-running protection with float switch.
Construction with SRLE level control for probes
connection against dry-running on request .

QTL 1 SS E Control panel for 1 pump with three-phase motor, start/stop with soft starter
Motor

Type
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1

kW

Max current
output
max A

Dimensions
HxBxP
mm

7,5
9,2
11 - 15
18,5 - 22
26
30
37
45
55
63
75
92
110
132

17
22
34
48
58
68
82
92
114
126
150
196
231
245

700x500x250
700x500x250
700x500x250
700x500x250
900x600x300
900x600x300
900x600x300
900x600x300
900x600x300
1100x700x300
1100x700x300
1200x800x400
1200x800x400
1200x800x400

400V - 3~

SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS

7,5 E
9,2 E
15 E
22 E
26 E
30 E
37 E
45 E
55 E
63 E
75 E
92 E
110 E
132 E

Construction
Control panel for 1 pump with three-phase
motor, start/stop with soft starter.
Operating signals on E 1000 led board.
Application: control of submersible motor with
great cable length and surface motors.
Dry-running protection with float switch.
Construction with SRLE level control for probes
connection against dry-running on request .

QTL 1 IS FTE Control panel for 1 pump with three-phase motor, with Stator Impedence starter
Motor 400V - 3~
Power
Current
kW
A

Type
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1
QTL 1

IS
IS
IS
IS
IS
IS
IS
IS
IS
IS
IS
IS
IS

5,5 FTE-2RL
7,5 FTE-2RL
11 FTE-2RL
15 FTE-2RL
18,5 FTE-2RL
22 FTE-2RL
30 FTE-2RL
37 FTE-2RL
45 FTE-2RL
55 FTE-2RL
75 FTE-2RL
92 FTE-2RL
110 FTE-2RL

5,5
7,5
9,2 - 11
15
18,5
22
30
37
45
55
75
92
110

11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42- 65
61 - 84
80 - 105
100 - 125
120 - 160
140 - 198
180 - 250

412

Dimensions
HxBxP
mm

Construction
Electromechanical control panel for 1
submersible pump with three-phase motor,
with Stator Impedence starter.
Operating signals on led board type E 1000.
Application : submersible motors control with
great cable length.
Construction with SRLE level control for
probes connection against dry-running .

CS, CS-R, FK

Submersible motors

Electric control panels


QML 1 VFT Control panel for 1 pump with variable speed three-phase motor

QML 1
QML 1
QML 1
QML 1

kW

Max current
output
max A

Dimensions
HxBxP
mm

0,37 - 0,45
0,55 - 0,75
1,1 - 1,5
2,2

2,6
4
7,1
10

500x350x200
500x350x200
500x350x200
500x350x200

Motor

Type

230V - 3~

VFT
VFT
VFT
VFT

0,4
0,75
1,5
2,2

Construction
Single-phase mains supply control panel with
frequency converter for 1 pump with three-phase
variable speed motor, for constant pressure
booster sets.
Arranged for SRL 3 level control application for
probes connection against dry-running.
Pump operation controlled by an electronic board
type MPS 4000 with microprocessor.

QTL 1 VFT Control panel for 1 pump with variable speed three-phase motor
Type
QTL 1 VFT 0,4
QTL 1 VFT 0,75
QTL 1 VFT 1,5
QTL 1 VFT 2,2
QTL 1 VFT 4
QTL 1 VFT 5,5
QTL 1 VFT 7,5
QTL 1 VFT 11
QTL 1 VFT 15
QTL 1 VFT 18,5
QTL 1 VFT 22
QTL 1 VFT 30
QTL 1 VFT 37
QTL 1 VFT 45
QTL 1 VFT 55
QTL 1 VFT 75

Motor
400V - 3~

kW
0,4
0,55 - 0,75
1,1 - 1,5
2,2
3-4
5,5
7,5
9,2 - 11
15
18,5
22
30
37
45
55
75

Max current
output
max A
1,5
2,3
4,1
5,5
9,5
14,3
17
27,7
33
41
48
66
79
94
116
160

Dimensions
HxBxP
mm
500x350x200
500x350x200
500x350x200
500x350x200
500x350x200
600x400x200
600x400x200
700x500x200
700x500x200
800x600x250
800x600x250
800x600x250
1100x700x300
1200x800x300
1200x800x300
1200x800x300

Construction
Control panel with frequency converter for 1
pump with three-phase variable speed motor,
for constant pressure booster sets.
Arranged for SRL 3 level control application for
probes connection against dry-running.
Pump operation controlled by an electronic
board type MPS 4000 with microprocessor.

45

413

CS, CS-R, FK

Submersible motors

Motor Cooling
To ensure a suitable cooling, water must be in touch with the motor casing with a minimum velocity according to the following table
Rewindable motor CS, CS-R series
Motor

8CS-R

25 C

Cooling:
minimum
flow velocity
0,08 m/s
0,1 m/s
0,2 m/s
0,2 m/s
0,2 m/s
0,1 m/s
0,3 m/s
0,3 m/s

10CS

25 C

0,50 m/s

4CS
6CS-R

Max.
Liquid
temperature
35 C
30 C
25 C
40 C

Encapsulated motor FK series


Max.
starts
per hour
20
15
15
15
13
13
6
10
8
6
10

Motor

Motor

P2
all types
411 kW
1315 kW
18,5 kW
2230 kW
37 kW
45 kW
3045 kW
5175 kW
92 kW
all types

4FK
6FK
8FK

Max. Liquid
temperature
30 C
30 C for 4 30 kW
50 C for 37 45 kW
30 C

Cooling
minimum flow velocity
0,08 m/s
0,16 m/s
0,16 m/s

Max. starts
per hour
20
20
20

For operation with higher temperatures, contact our Technical Sales Department

Cooling jacket
(fig. B)

When the submersible motor is installed :


- below the well inlet points (picture A);
- in tanks, lakes, basins, etc (pictures B and C)
an external jacket must be installed to create a
cooling flow around the motor. Only in this way
a safe operation can be assured avoiding any
overheating which can damage the motor.

4.93.324/2
CALPEDA

(fig. A)
4.93.324/2

(fig. C)

CALPEDA

CALPEDA

4.93.324/3

414

09/2016

NCE
Heating and conditioning

46

415

NCE EI

NCE EL

pag. 418

pag. 454

Energy saving circulating


pumps

Energy saving circulating


pumps for solar systems

NCE EA

NCE ES

pag. 422

pag. 458

Self-adapt energy saving


circulating pumps

Energy saving circulating


pumps for sanitary hot water

NCE H

NCE PS

pag. 426

pag. 462

Energy saving circulating


pumps

Energy saving circulating


pumps for sanitary hot water

NCE H F

NCS3

pag. 431

pag. 466

Energy saving circulating


pumps with flanges

Circulating pumps
for sanitary hot water

NCE HQ F

NC3

pag. 436

pag. 469

Energy saving circulating


pumps

Three speeds circulating


pumps with threaded ports

NCED HQ F

NCD3

pag. 440

pag. 473

Energy saving circulating


twin pumps with flanges

Three speeds circulating


pumps with threaded ports

NCE G F

NC

pag. 444

pag. 476

Energy saving circulating


pumps with flanges

Three speeds circulating


pumps with flanges

NCED G F

NCD

pag. 449

pag. 484

Energy saving circulating


twin pumps with flanges

Three speeds circulating


twin pumps with flanges
416

ENERGY EFFICIENCY OF CIRCULATING PUMPS


Directive of the European Parliament COMMISSION REGULATION (EC) No 641/2009 and 622/2012
Eco-design Directive of Energy Using Products (ErP Directive - Energy-related Products). The
European Union wants to improve the design of equipment that "consume" significant energy e.g.
(televisions, refrigerators, washing machines, boilers, pumps, and motors etc.) To improve ecodesign providing environmental sustainability, reduducing negative environmental impact as the
consequence of production, use and disposal of products.
The objective of the Directive is to force manufacturers and importers to produce and distribute
products with high energy efficiency, and carbon output.
The criteria for eco-design will be an integral part of the declaration of conformity (CE), which is a
necessary requirement/mark for products being sold in the EU.

This Regulation shall apply to:


Stand-alone* or integrated** circulators with the motor immersed in the pumped medium, with
hydraulic power from 1 up to 2500 W, designed for use in heating systems or in secondary circuits of cooling distribution systems.
* Stand alone circulators are commonly available on the market.
**
circulators integrated in products are component of a device, such as boilers, heat
pumps, etc..

a
i
Energ e

y
2015
2013

EEI < 0,23


EEI < 0,27
0,27 < EEI < 0,4
0,4 < EEI < 0,6
0,6 < EEI < 0,8

This Regulation shall not apply to:


a) drinking water circulators
b) circulators integrated in products and placed on the market not later than 1 January 2020 as
replacement for identical circulators integrated in products and placed on the market no later
than 1 August 2015. The replacement product or its packaging must clearly indicate the
product(s) for which it is intended.

0,8 < EEI < 1,0


1,0 < EEI < 1,2
1,2 < EEI < 1,4
EEI < 1,4

A
B
C
D
E
F
G

STANDARD OPERATING MODE IN CIRCULATING PUMPS


H
Proportional pressure curve
In the proportional pressure operating mode the pump changes the working pressure
in-line with the flow demand of the system.
This operating mode is mainly used in:
- two pipe heating systems with thermostatic valves,
- systems with long pipelines;
- systems with high head losses.
Constant pressure curve
In the constant pressure operating mode, the pump, keeps the pressure constant when
the demand for water changes.
This operating mode is mainly used in:
- two pipe heating systems with thermostatic valves and low head losses
- underfloor heating systems with thermostatic valves;
- one pipe heating systems with thermostatic valves.

+
Hset
2

Q
H

+
-

Hset

Q
H
Constant speed curve
In this operating mode the pump works as a traditional pump with a constant curve, the
operating curve can be chosen by the user within a range of curves.

max

RPMset

+
min

417

46

NCE EI

Energy saving circulating pumps


Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Small domestic heating systems.
Floor heating systems.

Operating conditions
- Liquid temperature from +2 C to +95 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 6 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 43 dB (A).
- Minimum suction pressure: 0,3 bar at 50 C
1,0 bar at 95 C
- Maximum glycol quantity: 40%
- EMC according to: EN 55014-1, EN 61000-3-2, EN 55014-2
- Connections: threaded ports ISO 228: G 1, G 1 1/2, G 2
- The benchmark for most efficient circulators is EEI 0,20.
- Minimun power: 3 W.

Motor
Synchronous motor with permanent magnet.
- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50 Hz
- Protection: IP 44
- Insulation class: H
- Class II appliance
- Overload protection (jammed rotor):
1) automatic protection with electronic rotor release
2) Overload thermal protector
- Cable: phases and neutral
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Designation
NCE EI 32 - 60 / 180
Series
Version
DN ports in mm
Max. head in dm
connection size mm

Special features on request


Brass or cast iron unions.
EPP thermal insulation shell.

Features
Compact design
The space saving NCE EI is a very compact circulating pump, allows inr easy installation in small domestic heating systems.

Easy to install and to adjust


Installing the NCE EI is considerably simplified by the quick setting and power installation plug.

Reliable
Like all our electronic circulating pumps, the NCE EI features the patented self-cleaning square chamber design, which eliminates any possibility of
rotor blockage.
Ceramic shaft
Hydraulics components are completely painted with cataphoresis.

Easy use
Operating range with fixed curves from 0,5 m to 7 m; possibility to choose 2 (1-2) proportional pressure curves and 2 (I-II) constant pressure curves.

418

NCE EI

Energy saving circulating pumps

Operating modes
max

PROPORTIONAL CURVE PROGRAMMING p-v


(GREEN LED)
Moving the switch to 1 or 2 setting, the pump operates with the proportional curve.
This mode ensures maximum energy efficiency.

min

CONSTANT CURVE PROGRAMMING p-c


(ORANGE LED)
Moving the switch to I or II setting, the pump operates with a constant curve according to the
selected flow rates.

MANUAL PROGRAMMING
(BLUE LED)
Setting the switch in any position between the MIN and MAX points, the most suitable operating curve
for the installation is manually selected.

max

min

max

min

WARNING!
- The red LED indicates that the pump is not rotating but is still under tension.
- White flashing LED : plant degassing requirement, air in the system.

Characteristic curves
NCE EI 15-40
NCE EI 25-40
NCE EI 32-40

NCE EI 15-60
NCE EI 25-60
NCE EI 32-60

EEI 0,19

EEI 0,20

NCE EI 15-70
NCE EI 25-70
NCE EI 32-70

EEI 0,21

46

CI-CII constant curve


P1-P2 proportional curve
min-max n fixed curves

419

NCE EI

Energy saving circulating pumps

Materials

Component

Pos. Material

Pump casing

Cast iron GJL 200 EN 1561

Impeller

Composite

Shaft

Ceramic

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Composite / Ferrite

Winding

Copper wire

Electronic card

Gasket

EPDM

Dimensions and weights


fM
90

29,5

45

DN

88

13,2
78

DN

230V

TYPE
DN
NCE EI 15-40/130

G1

NCE EI 25-40/130

G 1 1/2

NCE EI 25-40/180

G 1 1/2

NCE EI 32-40/180

G2

NCE EI 15-60/130/A

G1

NCE EI 25-60/130/A

G 1 1/2

NCE EI 25-60/180/A

G 1 1/2

NCE EI 32-60/180/A

G2

NCE EI 15-70/130

G1

NCE EI 25-70/130

G 1 1/2

NCE EI 25-70/180

G 1 1/2

NCE EI 32-70/180

G2

mm

P1

A max A min W max W min


0,17
0,17
0,33
0,33
0,44
0,44

0,03
0,03
0,03
0,03
0,03
0,03

22
22
42
42
56
56

3
3
3
3
3
3

fm

134

130

134
134
134
144
144

180
130
180
130
180

420

kg

Unions (on request)

1,67
1,81
1,96
2,10

DN

1,67
1,81
1,96

DN1

2,10

DN

DN1

(NCE . 15..)

G1

G 1/2

1,91
2,05

KIT G 1 - G 1/2

2,20

KIT G 1 1/2 - G 1

(NCE . 25..)

G 1 1/2

G1

2,34

KIT G 2 - G 1 1/4

(NCE . 32..)

G2

G 1 1/4

NCE EI

Energy saving circulating pumps

Examples of installations

Installation

Terminal box arrangement (on request)

12

46

421

NCE EA

Self-adapt energy saving circulating


pumps
Construction
Energy saving variable speed circulating pump self-adapt driven
by a permanent magnet synchronous motor (pm) controlled by
on board inverter.
EPP thermal insulation shell included.

Applications
Small domestic heating systems.
Floor heating systems.

Operating conditions
- Liquid temperature from +2 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 43 dB (A).
- Minimum suction pressure: 0,3 bar at 50 C
1,0 bar at 95 C
1,5 bar at 110 C
- Maximum glycol quantity: 40%
- EMC according to: EN 55014-1, EN 61000-3-2, EN 55014-2
- Connections: threaded ports ISO 228: G 1, G 1 1/2, G 2
- The benchmark for most efficient circulators is EEI 0,20.
- Minimun power: 3 W.

Motor
Synchronous motor with permanent magnet.
- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50 Hz
- Protection: IP 44
- Insulation class: H
- Class II appliance
- Overload protection (jammed rotor):
1) automatic protection with electronic rotor release
2) Overload thermal protector
- Cable: phases and neutral
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Designation
NCE EA 32 - 60 / 180
Series
Version
DN ports in mm
Max. head in dm
connection size mm

Special features on request


Brass or cast iron unions.

Features
Compact design
The space saving NCE EA is a very compact circulating pump, allows inr easy installation in small domestic heating systems.

Easy to install and to adjust


Installing the NCE EA is considerably simplified by the quick setting and power installation plug.

Reliable
Like all our electronic circulating pumps, the NCE EA features the patented self-cleaning square chamber design, which eliminates
any possibility of rotor blockage.
Ceramic shaft
Hydraulics components are completely painted with cataphoresis.
Program for automatic routine vent and release.

Easy use
Operating range with fixed curves from 0,5 m to 7 m; possibility to choose 3 (1-2-3) proportional pressure curves and 3 (I-II-III)
constant pressure curves.

422

NCE EA

Self-adapt energy saving circulating


pumps

Operating modes
AUTO CURVE PROGRAMMING Automatic mode
(VIOLET LED)
Moving the switch to the AUTO setting, the pump finds the best working point and it controls it at any
time.

min

max

AUTO

PROPORTIONAL CURVE PROGRAMMING p-v


(GREEN LED)
Moving the switch to the 1,2 or 3 setting, the pump operates with the proportional curve.
This mode ensures maximum energy efficiency.

min

CONSTANT CURVE PROGRAMMING p-c


(ORANGE LED)
Moving the switch to the I,II or III setting, the pump operates with a constant curve according to the
selected flow rates.

min

max

AUTO

MANUAL PROGRAMMING
(BLUE LED)
Setting the switch in any position between the MIN and MAX points, the most suitable operating curve
for the installation is manually selected.

max

AUTO

min

max

AUTO

WARNING!
- The red LED indicates that the pump is not rotating but is still under tension.
- White flashing LED : plant degassing requirement, air in the system.

Characteristic curves
NCE EA 15-40
NCE EA 25-40
NCE EA 32-40

NCE EA 15-60
NCE EA 25-60
NCE EA 32-60

EEI 0,19

EEI 0,20

NCE EA 15-70
NCE EA 25-70
NCE EA 32-70

EEI 0,21

46

CI-CII-CIII constant curve


P1-P2-P3 proportional curve
min-max n fixed curves

423

Self-adapt energy saving circulating


pumps

NCE EA
Materials

Component

Pos. Material

Pump casing

Cast iron GJL 200 EN 1561

Impeller

Composite

Shaft

Ceramic

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Composite / Ferrite

Winding

Copper wire

Electronic card

Gasket

EPDM

Dimensions and weights


fM

20

125
90

29,5

45

DN

150

88

13,2
78

DN

230V

TYPE
DN
NCE EA 15-40/130

G1

NCE EA 25-40/130

G 1 1/2

NCE EA 25-40/180

G 1 1/2

NCE EA 32-40/180

G2

NCE EA 15-60/130

G1

NCE EA 25-60/130

G 1 1/2

NCE EA 25-60/180

G 1 1/2

NCE EA 32-60/180

G2

NCE EA 15-70/130

G1

NCE EA 25-70/130

G 1 1/2

NCE EA 25-70/180

G 1 1/2

NCE EA 32-70/180

G2

P1

mm

A max A min W max W min


0,17
0,17
0,33
0,33
0,44
0,44

0,03
0,03
0,03
0,03
0,03
0,03

22
22
42
42
56
56

3
3
3
3
3
3

fm

134

130

134
134
134
144
144

180
130
180
130
180

424

kg

Unions (on request)

1,67
1,81
1,96
2,10

DN

1,67
1,81
1,96

DN1

2,10

DN

DN1

(NCE . 15..)

G1

G 1/2

1,91
2,05

KIT G 1 - G 1/2

2,20

KIT G 1 1/2 - G 1

(NCE . 25..)

G 1 1/2

G1

2,34

KIT G 2 - G 1 1/4

(NCE . 32..)

G2

G 1 1/4

NCE EA

Self-adapt energy saving circulating


pumps

Examples of installations

Installation

Terminal box arrangement (on request)

12

46

425

NCE H

Energy saving circulating pumps


Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Heating and conditioning systems.

Operating conditions
- Liquid temperature from +2 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 40 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 C
- 0,28 bar a 90 C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: threaded ports ISO 228: G 1 1/2, G 2.
- The benchmark for most efficient circulators is EEI 0,20.

Designation

Motor

NCE H 25 - 100 / 180

Synchronous motor with permanent magnet.


- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
- Protection: IP 44
- Insulation class: F
- Overload protection (integrated).
- Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Series
Version
DN ports in mm
Max. head in dm
connection size mm

Special features on request


Additional module: - analog input 0-10V
- remote on/off input
- output relay
Brass or cast iron unions.

Features
Smart pump
NCE H adapt its functions to the system: the circulator measures the pressure and the flow and adjusts the speed to the selected pressure.

Easy use
There are different operating modes selectable from the control panel.

426

NCE H

Energy saving circulating pumps

Operating modes

Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
Proportional pressure mode:
The circulator changes the pressure propotionally to the current flow.
The pressure value can be adjusted with the + and - buttons.

W
m
m3/h
kRPM

P5

Constant pressure mode:


The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.

32

Operating mode-control panel


Fixed speed mode:
The circulator works with constant curve and the curve could be changed
using + e - buttons.

NCE H could works in:


- automatic mode
- proportional pressure mode
- constant pressure mode
- fixed speed mode
- night mode

Night mode:.
When the liquid temperature fall by 15-20C the pump automatically swiches to
night mode, in practice the circulator works at minimum curve.
When the temperature rises again the pump comes back to the selected mode
The night mode could be selected with any operating mode.

The night mode could be selected with any


operating mode.

Coverage chart

12
11

NCE H

NCE H ..-120

10

NCE H ..-100

m
8

NCE H ..-80
7
6
5

NCE H ..-60

46

NCE H ..-40

2
1
0
0

Q m3/h

427

10

12

NCE H

Energy saving circulationg pumps

Characteristic curves
Hm

Hm

NCE H 25-40
NCE H 32-40

NCE H 25-60
NCE H 32-60

4
EEI 0,21

EEI 0,21

4
3

2
1
1
0

0
0

PW

m3/h
Q
l/min

100

50

PW
P1 max

50

80

30

60

Q m3/h

10

150

100

P1 max

P1 min

20
5

50

40

P1 min

10

m3/h 2
l/min

100

40
20

0 Q m3/h

10

Hm

Hm

NCE H 25-80
NCE H 32-80

9
8

EEI 0,21

12

NCE H 25-100
NCE H 32-100

10

EEI 0,21

7
8

6
5

6
4
4

3
2

2
1
0

0
m3/h 2
Q
l/min
0

PW
140
120
100
80
60
40
20
0

12

200

150

100

50

10

m3/h 2
l/min

PW

P1 max

12
200

150

100

50

10

P1 max

180
160
120
80

0 Q m3/h 2

P1 min
4

40
6

10

12

428

P1 min
0 Q m3/h 2

10

12

NCE H

Energy saving circulationg pumps

Characteristic curves
Hm
12

NCE H 25-120
NCE H 32-120

10

EEI 0,21

8
6
4
2
0
0
0

m3/h 2
l/min

PW

12
200

150

100

50

10

P1 max

180
160
120
80
40
0

P1 min
0 Q m3/h 2

10

12

46

429

NCE H

Energy saving circulationg pumps

Materials
9

Component

Pos. Material

Pump casing

Cast iron GJL 200 EN 1561

Impeller

Composite

Shaft

Stainless steel

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Stainless steel jacket

Winding

Copper wire

Electronic card

Gasket

EPDM

4
5

Examples of installations

Dimensions and weights


243
53

DN

190

DN
117

Unions (on request)

TYPE

1~ 230 V

P1

kg

60

180

4
4,1

10

90

180

4
4,1

1,15

10

140

180

4
4,1

1,5

10

180

180

4
4,1

NCE H 25-40/180
NCE H 32-40/180

G 1 1/2
G2

0,1

0,5

10

NCE H 25-60/180
NCE H 32-60/180

G 1 1/2
G2

7,5

0,1

0,75

NCE H 25-80/180
NCE H 32-80/180

G 1 1/2
G2

0,1

NCE H 25-100/180
NCE H 32-100/180

G 1 1/2
G2

10

11

0,1

NCE H 25-120/180
NCE H 32-120/180

G 1 1/2
G2

12

15

a
mm

DN

m3/h

A min A max W min W max

0,1

1,5

10

180

180

430

DN

DN1

TYPE

DN

DN1

G 1/2

KIT G 1 - G 1/2

(NCE . 15..)

G1

KIT G 1 1/2 - G 1

(NCE . 25..)

G 1 1/2

G1

KIT G 2 - G 1 1/4

(NCE . 32..)

G2

G 1 1/4

NCE H.F

Energy saving circulating pumps


with flanges
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Heating and conditioning systems.

Operating conditions
- Liquid temperature from +2 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 40 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 C
- 0,28 bar a 90 C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: Flanges according to PN 6/10, EN 1092-2,
DN 32, 40, 50.
- The benchmark for most efficient circulators is EEI 0,20.

Designation

Motor

NCE H 32 F - 60 / 220

Synchronous motor with permanent magnet.


- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
- Protection: IP 44
- Insulation class: F
- Overload protection (integrated).
- Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Series
Version
DN ports in mm
With flanges
Max. head in dm
connection size mm

Special features on request


Additional module: - analog input 0-10V
- remote on/off input
- output relay

Features
Smart pump
NCE H.F adapt its functions to the system: the circulator measures the pressure and the flow and adjusts the speed to the selected pressure.

46

Easy use
There are different operating modes selectable from the control panel.

431

NCE H.F

Energy saving circulating pumps


with flanges

Operating modes

Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
Proportional pressure mode:
The circulator changes the pressure propotionally to the current flow.
The pressure value can be adjusted with the + and - buttons.

W
m
m3/h
kRPM

P5

Constant pressure mode:


The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.

32

Operating mode-control panel


Fixed speed mode:
The circulator works with constant curve and the curve could be changed
using + e - buttons.

NCE H.F could works in:


- automatic mode
- proportional pressure mode
- constant pressure mode
- fixed speed mode
- night mode

Night mode:.
When the liquid temperature fall by 15-20C the pump automatically swiches to
night mode, in practice the circulator works at minimum curve.
When the temperature rises again the pump comes back to the selected mode
The night mode could be selected with any operating mode.

The night mode could be selected with any


operating mode.

Coverage chart

12
11

NCE H.F

NCE H.F ..-120

10

NCE H.F ..-100

m
8

NCE H.F ..-80


7
6
5

NCE H.F ..-60

4
3

NCE H.F ..-40

2
1
0
0

Q m3/h

432

10

12

NCE H.F

Energy saving circulating pumps


with flanges

Characteristic curves
Hm

Hm

NCE H 32F-40
NCE H 40F-40
NCE H 50F-40

EEI 0,21

NCE H 32F-60
NCE H 40F-60
NCE H 50F-60
EEI 0,21

4
3

2
1
1
0

0
0

PW

m3/h
Q
l/min
0

100

50

PW
P1 max

50

80

30

60

Q m3/h

10

150

100

P1 max

P1 min

20
5

50

40

P1 min

10

m3/h 2
l/min

100

40
20

0 Q m3/h

10

Hm

Hm

NCE H 32F-80
NCE H 40F-80
NCE H 50F-80

9
8

10

EEI 0,21

NCE H 32F-100
NCE H 40F-100
NCE H 50F-100

12

EEI 0,21

6
5

6
4
4

3
2

2
1
0

0
m3/h 2
Q
0 l/min

150

100

50

PW
140
120
100
80
60
40
20
0

10

12

200

m3/h 2
l/min

12
200

150

PW

P1 max

10

100

50

46

P1 max

180
160
120
80

0 Q m3/h 2

P1 min
4

40
6

10

12

433

P1 min
0 Q m3/h 2

10

12

NCE H.F

Energy saving circulating pumps


with flanges

Characteristic curves
Hm

NCE H 32F-120
NCE H 40F-120
NCE H 50F-120

12
10

EEI 0,21

8
6
4
2
0
0
0

m3/h 2
l/min

PW

12
200

150

100

50

10

P1 max

180
160
120
80
40
0

P1 min
0 Q m /h 2
3

10

12

434

NCE H.F

Energy saving circulating pumps


with flanges

Materials
9

Component

Pos. Material

Pump casing

Cast iron GJL 200 EN 1561

Impeller

Composite

Shaft

Stainless steel

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Stainless steel jacket

Winding

Copper wire

Electronic card

Gasket

EPDM

4
5

Examples of installations

Dimensions and weights

DN

a
100

DN
117

TYPE

DN
DG
DK
DK
DE

190

53
243

DN

m3/h

1~ 230 V

P1

holes
fori

mm

kg

DN

DE

DK

DG

7,4
8,5
9,8

N.

60

220
220
240

32
40

140
150

90/100
100/110

74
80

4
4

14/19
14/19

7,4
8,5
9,8

50

165

110/125

90

14/19

90

220
220
240

7,4
8,5
9,8

A min A max W min W max

NCE H 32F-40/220
NCE H 40F-40/220
NCE H 50F-40/240

32
40
50

NCE H 32F-60/220
NCE H 40F-60/220
NCE H 50F-60/240

32
40
50

NCE H 32F-80/220
NCE H 40F-80/220
NCE H 50F-80/240

32
40
50

0,1

1,15

10

140

220
220
240

NCE H 32F-100/220
NCE H 40F-100/220
NCE H 50F-100/240

32
40
50

10

11

0,1

1,5

10

180

220
220
240

7,4
8,5
9,8

NCE H 32F-120/220
NCE H 40F-120/220
NCE H 50F-120/240

32
40
50

12

15

0,1

1,5

10

180

220
220
240

7,5

0,1

0,1

0,5

0,75

10

10

435

46

NCE HQ.F

Energy saving circulating pumps


with flanges
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Heating and conditioning systems.

Operating conditions
- Liquid temperature from +2 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 40 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 C
- 0,28 bar a 90 C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: Flanges according to PN 6/10, EN 1092-2,
DN 32, 40, 50.
- The benchmark for most efficient circulators is EEI 0,20.

Designation

Motor

NCE HQ 32 F - 60 / 220

Synchronous motor with permanent magnet.


- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
- Protection: IP 44
- Insulation class: F
- Overload protection (integrated).
- Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Series
Version
DN ports in mm
With flanges
Max. head in dm
connection size mm

Special features on request


Additional module: - analog input 0-10V
- remote on/off input
- output relay

Features
Smart pump
NCE HQ.F adapt its functions to the system: the circulator measures the pressure and the flow and adjusts the speed to the selected pressure.

Easy use
There are different operating modes selectable from the control panel.

436

NCE HQ.F

Energy saving circulating pumps


with flanges

Operating modes

Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
Proportional pressure mode:
The circulator changes the pressure propotionally to the current flow.
The pressure value can be adjusted with the + and - buttons.

W
m
m3/h
kRPM

P5

Constant pressure mode:


The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.

32

Operating mode-control panel


Fixed speed mode:
The circulator works with constant curve and the curve could be changed
using + e - buttons.

NCE HQ.F could works in:


- automatic mode
- proportional pressure mode
- constant pressure mode
- fixed speed mode
- night mode

Night mode:.
When the liquid temperature fall by 15-20C the pump automatically swiches to
night mode, in practice the circulator works at minimum curve.
When the temperature rises again the pump comes back to the selected mode
The night mode could be selected with any operating mode.

The night mode could be selected with any


operating mode.

Coverage chart

12

NCE HQ.F

11
10

NCE HQ.F 40-120

m
8
7
6

NCE HQ.F 40-80

NCE HQ.F 50-120


4

46

NCE HQ.F 40-40

2
1
0
0

Q m3/h

10

20

437

30

40

NCE HQ.F

Energy saving circulating pumps


with flanges

Characteristic curves
Hm

Hm

NCE HQ 40F-40

NCE HQ 40F-80

EEI 0,21

EEI 0,21

7
6

5
4

3
2

1
0

0
0

PW

m3/h
Q
l/min
0

16

14

12

10

200

100

300

P1 max

100

PW

80

200

m3/h 4
l/min

10

14

12

16

20

300

200

100

18

P1 max

60
100

40
20
0

P1 min

P1 min
0

Q m3/h

12

10

16

14

0 Q m3/h

10

14

12

18

20

Hm

Hm

NCE HQ 40F-120

12

NCE HQ 50F-120

12

EEI 0,21

EEI 0,21

10

10

2
0

0
m3/h 4
Q
l/min
0

12

24

400

300

200

100

20

16

PW

400

300

300

200

200

0 Q m /h 4

12

16

20

12

18

600

450

300

150

36

30

24

P1 max

100

P1 min
3

m3/h 6
l/min

500

400

100

PW

P1 max

500

16

24

438

P1 min
0 Q m /h 2
3

10

12

Energy saving circulating pumps


with flanges

NCE HQ.F
Materials

Component

Pos. Material

Pump casing

Cast iron GJL 200 EN 1561

Impeller

Composite

Shaft

Stainless steel

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Stainless steel jacket

Winding

Copper wire

Electronic card

Gasket

EPDM

4
5

Examples of installations

Dimensions and weights

DN

a
108

DN
72

293

74

1~ 230 V

DN

3/h

NCE HQ 40F-40/250

40

12

0,1

10

NCE HQ 40F-80/250

40

16

0,2

1,4

NCE HQ 40F-120/250

40

12

23

0,2

NCE HQ 50F-120/280

50

12

35

02

TYPE

DN
DG
DK
DK
DE

228

65

P1

fori

mm

kg

110

250

25

270

250

2,2

25

480

250

2,5

25

560

280

A min A max W min W max

439

DN

DE

DK

DG

N.

32
40

140
150

90/100
100/110

74
80

4
4

14/19
14/19

50

165

110/125

90

14/19

46

NCED HQ.F

Energy saving twin circulating


pumps with flanges
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Heating and conditioning systems.

Operating conditions
- Liquid temperature from +2 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 40 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 C
- 0,28 bar a 90 C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: Flanges according to PN 6/10, EN 1092-2,
DN 32, 40, 50.
- The benchmark for most efficient circulators is EEI 0,20.

Designation

Motor

NCE D HQ 32 F - 60 / 220

Synchronous motor with permanent magnet.


- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
- Protection: IP 44
- Insulation class: F
- Overload protection (integrated).
- Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.
- Additional module: - analog input 0-10V
- remote on/off input
- output relay

Series
Twin pumps version
Version
DN ports in mm
With flanges
Max. head in dm
connection size mm

Features
Operation

Smart pump
NCED HQ.F adapt its functions to the system: the circulator measures
the pressure and the flow and adjusts the speed to the selected
pressure.

Easy use
There are different operating modes selectable from the control panel.

Single operation
Operation of a single pump
choosed by the customer, with
the second pump on stand-by

440

Double operation
Operation in parallel of the
two pumps

NCED HQ.F

Energy saving twin circulating


pumps with flanges

Operating modes

Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
Proportional pressure mode:
The circulator changes the pressure propotionally to the current flow.
The pressure value can be adjusted with the + and - buttons.

W
m
m3/h
kRPM

P5

Constant pressure mode:


The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.

32

Operating mode-control panel


Fixed speed mode:
The circulator works with constant curve and the curve could be changed
using + e - buttons.

NCED HQ.F could works in:


- automatic mode
- proportional pressure mode
- constant pressure mode
- fixed speed mode
- night mode

Night mode:.
When the liquid temperature fall by 15-20C the pump automatically swiches to
night mode, in practice the circulator works at minimum curve.
When the temperature rises again the pump comes back to the selected mode
The night mode could be selected with any operating mode.

The night mode could be selected with any


operating mode.

Coverage chart

12

NCED HQ.F

11
10

NCED HQ.F 40-120

m
8
7
6

NCED HQ.F 40-80

NCED HQ.F 50-120


4

46

NCED HQ.F 40-40

2
1
0
0

Q m3/h

10

20

441

30

40

Energy saving twin circulating


pumps with flanges

NCED HQ.F
Characteristic curves

Hm

Hm

NCED HQ 40F-40

NCED HQ 40F-80

EEI 0,21

EEI 0,21

7
6

5
4

3
2

1
0

0
0

PW

m3/h
Q
l/min
0

16

14

12

10

200

100

300

P1 max

100

PW

80

200

m3/h 4
l/min

10

14

12

16

20

300

200

100

18

P1 max

60
100

40
20
0

P1 min

P1 min
0

Q m3/h

12

10

16

14

0 Q m3/h

10

14

12

18

20

Hm

Hm

NCED HQ 40F-120

12

NCED HQ 50F-120

12

EEI 0,21

EEI 0,21

10

10

2
0

0
m3/h 4
Q
l/min
0

12

24

400

300

200

100

20

16

PW

400

300

300

200

200

0 Q m /h 4

12

16

20

12

18

600

450

300

150

36

30

24

P1 max

100

P1 min
3

m3/h 6
l/min

500

400

100

PW

P1 max

500

16

24

442

P1 min
0 Q m /h 2
3

10

12

Energy saving twin circulating


pumps with flanges

NCED HQ.F
Materials

Component

Pos. Material

Pump casing

Cast iron GJL 200 EN 1561

Impeller

Composite

Shaft

Stainless steel

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Stainless steel jacket

Winding

Copper wire

Electronic card

Gasket

EPDM

4
5

Examples of installations

Dimensions and weights

DN

a
108

228

65
DN
?

293

1~ 230 V

DN

3/h

NCED HQ 40F-40/250

40

12

0,1

10

NCED HQ 40F-80/250

40

16

0,2

1,4

NCED HQ 40F-120/250

40

12

23

0,2

NCED HQ 50F-120/280

50

12

35

02

TYPE

DN
DG
DK
DK
DE

P1

46

fori

mm

kg

DN

N.

110

250

25

270

250

32
40

140
150

90/100
100/110

74
80

4
4

14/19
14/19

50

165

110/125

90

14/19

2,2

25

480

250

2,5

25

560

280

A min A max W min W max

443

DE

DK

DG

NCE G.F

Energy saving circulating pumps


with flanges
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Heating, conditioning, circulating systems.
For civil and industrial applications.

Operating conditions
- Liquid temperature from -10 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 6/10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 54 dB (A).
- Minimum suction pressure: - 0,5 bar at 50 C.
- 0,8 bar at 80 C.
- 1,4 bar at 110 C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: Flanges according to PN 6/10, EN 1092-2,
DN 50, 65, 80, 100.
- The benchmark for most efficient circulators is EEI 0,20.

Designation
NCE G 40 F - 120 / 250

Motor

Series

Synchronous motor with permanent magnet.


- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
- Protection: IP 44
- Insulation class: H
- Overload protection (integrated).
- Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Version
DN ports in mm
With flanges
Max. head in dm
connection size mm

Features
Smart pump
NCE G.F adapt its functions to the system: the circulator measures the pressure and the flow and adjusts the speed to the selected pressure.

Easy use
There are different operating modes selectable from the control panel.

444

NCE G.F

Energy saving circulating pumps


with flanges

Operating modes

Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
Proportional pressure mode:
The circulator changes the pressure propotionally to the current flow.
The pressure value can be adjusted with the + and - buttons.

W
m
m3/h
kRPM

32

P5

Constant pressure mode:


The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.

Operating mode-control panel


Fixed speed mode:
The circulator works with constant curve and the curve could be changed
using + e - buttons.

NCE G.F could works in:


- automatic mode
- proportional pressure mode
- constant pressure mode
- fixed speed mode
The night mode could be selected with any
operating mode.

Coverage chart
18

NCE G

16
14

65

F-

18

80

F-

18

0,

11

50

10

F-

18

10

0F

-18

8
7
6

65

5
4

F-1

80F

30

-13

0,

100

46
F-1

30

2
1
0

Q m3/h 10

20

30

40
445

50

60

70

Energy saving circulating pumps


with flanges

NCE G.F
Characteristic curves

Hm

Hm

12

NCE G 65F-130

14

NCE G 80F-130
NCE G 100F-130

EEI 0,23

12

EEI 0,23

10

10
8
8
6
6
4

2
0
PW

m3/h 10
Q
l/min
0
200

20
300

30
400

40

500

600

700

50
800

0 m3/h10
Q

900

(%)

PW

20

0 l/min

30

40

50

60

500

70

80

1000

(%)

1000

P1 max 50

2000

800

40

1600

40

600

30

1200

30

400

20

800

20

200

10

400

0 Q m3/h

10

P1 min
30

20

40

50

Hm

10
0 Q m3/h10

20

P1 min
30

40

50

60

16

80

NCE G 65F-180

16
EEI 0,23

EEI 0,23

14

14

12

12

10

10

2
0 m3/h 5
Q

PW

70

Hm

NCE G 50F-180

50

P1 max

0 l/min 100

10
200

15

20
300

25
400

30
500

35

40

600

(%)

PW

0
0

m3 /h 10
l/min
100

20

40

30
200

300

50
400

60
500

(%)

2000

1000

P1 max 50
40

800

30

1200

30

600

20

800

20

400

10

400

10

1200

200

0 Q m3/h 5

10

P1 min
15

20

25

30

35

40

50
P1 max

1600

446

0 Q m3 /h 10

20

30

40

50

40

60

NCE G.F

Energy saving circulating pumps


with flanges

Characteristic curves

Hm
16

NCE G 80F-180
NCE G 100F-180

14

EEI 0,23

12
10
8
6
4
2
0
PW

0
0

m3 /h
l/min 100

30

20

40
300

200

50

60

400

500

2000

P1 max

70

(%)
50

1600

40

1200

30

800

20

400

10

0 Q m3 /h

20

30

40

50

60

0
70

46

447

NCE G.F

Energy saving circulating pumps


with flanges

Materials
9

Component

Pos. Material
2

Pump casing

Cast iron

Impeller

Stainless steel

Shaft

Stainless steel

Bearings

Carbon

Thrust bearing

Steel

Rotor

Stainless steel jacket

Winding

Copper wire

Electronic card

Gasket

EPDM

4
5

Examples of installations

Dimensions and weights


fM
h1

DN 50, 65
PN6/10

DN 80, 100
PN10

DN

255

a/2

DN
DG
DK
DK
DE

H
DN
TYPE

1~
230 V

P1

DN
DG
DK
DE

mm

fori
holes
DE

DK

DG

DN

m3/h

kg

DN

N.

NCE G 50F-180/280

50

17

40

10

1100 280 425 70 200

30

NCE G 65F-130/340

65

13

65

10

1100 340 449 80 222

36

50
65

165
185

110/125
130/145

90
110

4
4

14/19
14/19

NCE G 65F-180/340

65

17

60

10

1500 340 483 80 222

39

NCE G 80F-130/360

80

13

78

10

1600 360 503 100 230

44

80
100

200
220

160
180

128
-

8
8

19
19

NCE G 80F-180/360

80

17

62

10

1600 360 503 100 230

41

NCE G 100F-130/360

100

13

78

10

1600 360 513 110 230

47

NCE G 100F-180/360

100

17

62

10

1600 360 513 110 230

43

A max

W min W max

fM

448

h1

NCED G.F

Energy saving twin circulating pumps


with flanges
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Heating, conditioning, circulating systems.
For civil and industrial applications.

Operating conditions
- Liquid temperature from -10 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 6/10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 54 dB (A).
- Minimum suction pressure: - 0,5 bar at 50 C.
- 0,8 bar at 80 C.
- 1,4 bar at 110 C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: Flanges according to PN 6/10, EN 1092-2,
DN 40, 50, 65, 80, 100.
- The benchmark for most efficient circulators is EEI 0,20.

Designation
NCE D G 40 F - 120 / 250

Motor

Series

Synchronous motor with permanent magnet.


- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
- Protection: IP 44
- Insulation class: H
- Overload protection (integrated).
- Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Twin pumps version


Version
DN ports in mm
With flanges
Max. head in dm
connection size mm

Features
Operation

Smart pump
NCED G.F adapt its functions to the system: the circulator measures the
pressure and the flow and adjusts the speed to the selected pressure.

46

Easy use
There are different operating modes selectable from the control panel.
Single operation
Operation of a single pump choosed by the
customer, with the second pump on stand-by

449

NCED G.F

Energy saving twin circulating pumps


with flanges

Operating modes

Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
Proportional pressure mode:
The circulator changes the pressure propotionally to the current flow.
The pressure value can be adjusted with the + and - buttons.

W
m
m3/h
kRPM

32

P5

Constant pressure mode:


The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.

Operating mode-control panel


Fixed speed mode:
The circulator works with constant curve and the curve could be changed
using + e - buttons.

NCED G.F could works in:


- automatic mode
- proportional pressure mode
- constant pressure mode
- fixed speed mode
The night mode could be selected with any
operating mode.

Coverage chart
18

NCED
NCE G
G

16
14

65

F-

18

80

F-

11

50

10

188
00,F
1-01
08F0
-18

F-

18

8
7
6

65

5
4

F-1

80F

30

-138
00, F10103
F0-1
3

2
1
0

Q m3/h 10

20

30

40
450

50

60

70

Energy saving twin circulating pumps


with flanges

NCED G.F
Characteristic curves
Hm

Hm

NCED G 80F-130

14

NCED G 65F-130

12

EEI 0,23

EEI 0,23

12

10

10
8
8
6
6
4

2
0
PW

m3/h 10
l/min
200

20
300

30
400

40

500

600

700

50
800

0 m3/h10
Q

900

(%)

PW

20

0 l/min

30

40

50

60

500

70

80

1000

(%)

1000

P1 max 50

2000

800

40

1600

40

600

30

1200

30

400

20

800

20

200

10

400

0 Q m3/h

10

P1 min
30

20

40

50

Hm

10
0 Q m3/h10

20

P1 min
30

40

50

60

16

80

NCED G 65F-180

16
EEI 0,23

EEI 0,23

14

14

12

12

10

10

2
0 m3/h 5
Q

PW

70

Hm

NCED G 50F-180

50

P1 max

0 l/min 100

10
200

15

20
300

25
400

30
500

35

40

600

(%)

PW

0
0

m3 /h 10
l/min
100

20

40

30
200

300

50
400

60
500

(%)

P1 max 50
40

2000

1000
800

30

1200

30

600

20

800

20

400

10

400

10

1200

200

0 Q m3/h 5

10

P1 min
15

20

25

30

35

40

50
P1 max

1600

451

0 Q m3 /h 10

20

30

40

50

40

60

46

Energy saving twin circulating pumps


with flanges

NCED G.F
Characteristic curves

Hm

NCED G 80F-180

16

EEI 0,23

14
12
10
8
6
4
2
0
PW

0
0

m3 /h
l/min 100

20

30

40
300

200

50

60

400

500

2000

P1 max

70

(%)
50

1600

40

1200

30

800

20

400

10

0 Q m3 /h

20

30

40

50

60

0
70

452

Energy saving twin circulating pumps


with flanges

NCED G.F
Materials

Component

Pos. Material

Pump casing

Cast iron

Impeller

Stainless steel

Shaft

Stainless steel

Bearings

Carbon

Thrust bearing

Steel

Rotor

Stainless steel jacket

Winding

Copper wire

Electronic card

Gasket

EPDM

4
5

Examples of installations

Dimensions and weights


fM
h1
DN

DN 80
PN10

DN 50, 65
PN6/10

255

a/2

DN
DG
DK
DK
DE

DN

TYPE

Q
3

1~
230 V

P1

DN
DG
DK
DE

46

mm

fori
holes
DE

DK

DG

DN

m /h

kg

DN

N.

NCED G 50F-180/280

50

17

40

10

1100 280 425 70 403

59

NCED G 65F-130/340

65

13

65

10

1100 340 449 80 452

64

50
65

165
185

110/125
130/145

90
110

4
4

14/19
14/19

NCED G 65F-180/340

65

17

60

10

1500 340 483 80 452

73

80

200

160

128

19

NCED G 80F-130/360

80

13

78

10

1600 360 503 100 462

78

NCED G 80F-180/360

80

17

62

10

1600 360 503 100 452

76

A max

W min W max

453

fM

h1

NCE EL

Energy saving circulating pumps


for solar systems
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter.

Applications
Solar thermal systems.

Operating conditions
- Liquid temperature from +2 C to +110 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 43 dB (A).
- Minimum suction pressure: 0,3 bar at 50 C
1,0 bar at 95 C
1,5 bar at 110 C
- Maximum glycol quantity: 40%
- EMC according to: EN 55014-1, EN 61000-3-2, EN 55014-2
- Connections: threaded ports ISO 228: G 1, G 1 1/2.
- The benchmark for most efficient circulators is EEI 0,20.
- Minimun power: 3 W.

Motor
Synchronous motor with permanent magnet.
- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50 Hz
- Protection: IP 44
- Insulation class: H
- Class II appliance
- Overload protection (jammed rotor):
1) automatic protection with electronic rotor release
2) Overload thermal protector
- Cable: phases and neutral
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Designation
NCE EL 25 - 60 / 180
Series
Version
DN ports in mm
Max. head in dm
connection size mm

Special features on request


Brass or cast iron unions.

Features
Compact design
The space saving NCE EL is a very compact circulating pump, allows inr easy installation in small domestic heating systems.

Easy to install and to adjust


Installing the NCE EL is considerably simplified by the quick setting and power installation plug.

Reliable
Like all our electronic circulating pumps, the NCE EL features the patented self-cleaning square chamber design, which eliminates any possibility of
rotor blockage.
Ceramic shaft.
Hydraulics components are completely painted with cataphoresis.
Program for automatic routine vent and release.

Easy use
Operating range with fixed curves from 0,6 m to 7 m; possibility to choose proportional pressure curve or selection of the optimum working point.

454

NCE EL

Energy saving circulating pumps


for solar systems

Operating modes
PROPORTIONAL CURVE PROGRAMMING p-v
(GREEN LED)
Moving the switch to the P setting will allow the pump to operate against a proportional performance
curve. This feature ensures maximum energy efficiency.

max

min

MANUAL PROGRAMMING
(BLUE LED)
Setting the switch in any position between the MIN and MAX points, the most suitable operating curve
for the installation is manually selected.

max

min

WARNING!
- The red LED indicates that the pump is not rotating but is still under tension.
- White flashing LED : plant degassing requirement, air in the system.

Characteristic curves

NCE EL 15-70
NCE EL 25-70

NCE EL 15-60
NCE EL 25-60

EEI 0,21

EEI 0,20

46

P proportional curve
min-max n fixed curves

455

Energy saving circulating pumps


for solar systems

NCE EL
Materials

Component

Pos. Material

Pump casing

Cast iron GJL 200 EN 1561

Impeller

Composite

Shaft

Ceramic

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Composite / Ferrite

Winding

Copper wire

Electronic card

Gasket

EPDM

Dimensions and weights

fM
90

29,5

45

DN

88

Unions (on request)


13,2
78

DN

230V

TYPE
DN
NCE EL 15-60/130/A

G1

NCE EL 25-60/130/A

G 1 1/2

NCE EL 25-60/180/A

G 1 1/2

NCE EL 15-70/130

G1

NCE EL 25-70/130

G 1 1/2

NCE EL 25-70/180

G 1 1/2

P1

DN

mm

A max A min W max W min

fm

0,33

0,03

42

134

130

0,33

0,03

42

134

180

0,44

0,03

56

144

130

0,44

0,03

56

144

180

456

kg
1,67

DN1

1,81
1,96
1,91

KIT G 1 - G 1/2

2,05

KIT G 1 1/2 - G 1
KIT G 2 - G 1 1/4

2,20

DN

DN1

(NCE . 15..)

G1

G 1/2

(NCE . 25..)

G 1 1/2

G1

(NCE . 32..)

G2

G 1 1/4

NCE EL

Energy saving circulating pumps


for solar systems

Examples of installations

Installation

Terminal box arrangement (on request)

12

46

457

NCE ES

Energy saving circulating pumps


for sanitary hot water
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter. Bronze pump casing.

Applications
Hot sanitary water systems.

Operating conditions
- Liquid temperature from +2 C to +95 C
- Ambient temperature from +2 C to +40 C
- Maximum working pressure: 10 bar
- Storage: -20C/+70C UR 95% a 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 43 dB (A).
- Minimum suction pressure: 0,3 bar at 50 C
1,0 bar at 95 C
- EMC according to: EN 55014-1, EN 55014-2, EN 61000-3-2,
EN 61000-3-3.
- Threated ports ISO 228: G 1, G 1 1/4, G 1 1/2.

Motor
Synchronous motor with permanent magnets.
- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50 Hz
- Protection: IP 44
- Insulation class: H
- Class II appliance
- Overload protection (jammed rotor):
1) automatic protection with electronic rotor release
2) overload thermal protector
- Cable: phases and neutral
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Designation
NCE ES 25 - 40 / 130
Series
Version
DN ports in mm
Max. head in dm
connection size mm

Special features on request


Brass unions.

Features
Energy saving
NCE ES is an high energy efficiency product.

Patented

Compact design
The space saving NCE ES facilitate the installation in the smaller systems.

Easy to install and to adjust


Installing the NCES is considerably simplified by the quick setting and power installation plug. The adjustment is simple and
intuitive thanks to the ability to be able to select the optimum working point or mode via a simple LED indicator and switch.

Reliability
NCES features the patented self-cleaning square chamber design, which eliminates any possibility of rotor blockage.

Easy use
Operating range with fixed curves from 0,6 m to 4 m with selection of the optimum working point.

458

Escape routes for


impurities inside the
rotor chamber

NCE ES

Energy saving circulating pumps


for sanitary hot water

Operating modes

MANUAL PROGRAMMING
(BLUE LED)
Setting the switch in any position between the MIN and MAX points, the most suitable operating curve
for the installation is manually selected.

max

min

WARNING!
- The red LED indicates that the pump is not rotating but is still under tension.
- White flashing LED : plant degassing requirement, air in the system.

Characteristic curves

NCE ES 15-40
NCE ES 20-40
NCE ES 25-40

14

12

10

8
2
6

4
1

46
2

459

Energy saving circulating pumps


for sanitary hot water

NCE ES
Materials

Component

Pos. Material

Pump casing

Bronze

Impeller

Composite

Shaft

Ceramic

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Composite / Ferrite

Winding

Copper wire

Electronic card

Gasket

EPDM

Dimensions and weights

144
90

29,5

45

DN

88

Unions (on request)

13,2
88

DN

DN

DN1

P1

mm

W max W min

Net
weight
kg

230V
TYPE

DN

A max

A min

G1

0,35

0,03

44

4,5

130

2,15

NCE ES 20-40/130

G 1 1/4

0,35

0,03

44

4,5

130

2,25

NCE ES 25-40/130

G 1 1/2

0,35

0,03

44

4,5

130

2,35

NCE ES 15-40/130

460

TYPE

DN

DN1

G1

G 1/2

KIT G 1 1/4 - G 3/4 (NCE ES 20..)

G 1 1/4

G 3/4

KIT G 1 1/2 - G 1

G 1 1/2

G1

KIT G 1 - G 1/2

(NCE ES 15..)
(NCE ES 25..)

NCE ES

Energy saving circulating pumps


for sanitary hot water

Examples of installations

Installation

Terminal box arrangement (on request)

12

46

461

NCE PS

Energy saving circulating pumps


for sanitary hot water
Construction
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on
board inverter. Bronze pump casing.

Applications
Sanitary hot water systems.

Operating conditions
- Liquid temperature from +5 C to +65 C
- Ambient temperature from 0 C to +40 C
- Maximum permissible working pressure: 10 bar
- Storage: -20C/+70C max. relative humidity 95% at 40 C
- Certifications: in conformity with CE requirements
- Sound pressure 38 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 C
- 0,28 bar a 90 C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: threaded ports ISO 228: G 1 1/4, G 1 1/2.

Motor
Synchronous motor with permanent magnet.
- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50 Hz
- Protection: IP 44
- Insulation class: F
- Overload protection (integrated).
- Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.

Designation
NCE PS 25 - 60 / 180
Series
Version for sanitary hot water
DN ports in mm
Max. head in dm
connection size mm

Special features on request


The NCE PR version is equipped with an additional module
that allows to control the pump with an analog signal 0-10V.
Brass unions.

Features
Easy adjustment
The adjustment is simple and intuitive thanks to the LEDindicator.

Easy use
3 proportional curves and 3 fixed speed curves are available and selectable by the button.

462

NCE PS

Energy saving circulating pumps


for sanitary hot water

Operating modes

Operating functions - control buttons.


NCE PS circulator could work:
- with proportional pressure curves
- with fixed speed curves

PROPORTIONAL CURVE PROGRAMMING p-v


(P1 BLUE LED blinking light)
(P2 GREEN LED blinking light)
(P3 YELLOW LED blinking light)
Push repeatedly the button to select the proportional curve.
The color changes depending on the selected curve.
This operating mode guarantees the maximum energy efficiency.

FIXED SPEED CURVE PROGRAMMING


(I BLUE LED light)
(II GREEN LED light)
(III YELLOW LED light)
If you push the button for 5 seconds the pump adopt the fixed speed curve. The color changes
depending on the selected curve. (to replace standard 3-speed circulators).

Coverage chart
10

NCE PS

m
8
7
NCE PS ..-80

6
5
NCE PS ..-60

4
3

46

NCE PS ..-40

2
1
0

Q m3/h

3
463

Energy saving circulating pumps


for sanitary hot water

NCE PS
Characteristic curves
Hm

Hm

NCE PS 20-40
NCE PS 25-40

NCE PS 20-60
NCE PS 25-60

6
5

P3

P3

P2

P2
2

P1

P1

2
1
1
0
0

m3/h
l/min 10

2
20

30

3
40

50

0
0

m3/h
l/min 10

2
20

30

3
40

50

PW
50

PW
25

40

20

30

15
10

20

10

0 Q m3/h

Hm

NCE PS 20-80
NCE PS 25-80

P3

P2
4

P1

0
0
0

m 3/h
l/min

2
20

30

3
40

50

4
60

5
70

80

90

PW
75
60
45
30
15
0
3
0 Q m /h

464

0 Q m3/h

NCE PS

Energy saving circulating pumps


for sanitary hot water

Materials
9

Component

Pos. Material

Pump casing

Bronze

Impeller

Composite

Shaft

Ceramic

Bearings

Carbon

Thrust bearing

Ceramic

Rotor

Stainless steel jacket

Winding

Copper wire

Electronic card

Gasket

EPDM

4
5

Examples of installations

Dimensions and weights


128

DN

20

Unions (on request)


a

DN
DN
80

TYPE

DN

DN1

108

48

m3/h

NCE PS 20-40/130
NCE PS 25-40/130

G 1 1/4
G 1 1/2

NCE PS 20-60/130
NCE PS 25-60/130

G 1 1/4
G 1 1/2

NCE PS 20-80/130
NCE PS 25-80/130

G 1 1/4
G 1 1/2

2,6
3,7
4,5

1~ 230 V
A min

0,05
0,05
0,05

P1

A max W max

0,2
0,4
0,6

25
50
75

TYPE

DN

DN1

G1

G 1/2

mm

kg

KIT G 1 - G 1/2

130

2,1
2,2

KIT G 1 1/4 - G 3/4 (NCE . 20..)

G 1 1/4

G 3/4

(NCE . 25..)

G 1 1/2

G1

130

2,1
2,2

KIT G 1 1/2 - G 1
KIT G 2 - G 1 1/4

(NCE . 32..)

G2

G 1 1/4

130

2,1
2,2

465

(NCE . 15..)

46

NCS3

Circulating pumps for sanitary hot water


Construction
Bronze pump casing with suction and delivery connections with
the same diameter and on the same axis (in-line).
Stainless steel AISI 316 can.

Materials
Pump casing
Impeller
Shaft
Bearings

NCS3 ..-40, -50


Bronze
Composite
Stainless steel
Graphite

NCS3 ...-70
Bronze
Composite
Ceramic
Ceramic

Applications
Circulation of sanitary hot water.

Operating conditions
Liquid temperature from +5 C to +65 C.
Ambient temperature up to 40 C.
Sound pressure 43 dB (A).
Minimum suction pressure: 0,05 bar at 50 C
Maximum permissible working pressure 10 bar.

Designation
NCS3 2 0 - 4 0 / 1 3 0

Motor
2-pole induction motor, 50 Hz.
Three adjustable speeds.
NCS3: single-phase 230 V.
Insulation class H.
Protection IP 44.

Series
DN ports in mm
Max. head in dm
connection size mm

Special features on request


Brass unions.

Coverage chart
7

NCS3

6
NCS
3 ..-7
0

NCS
3 ..-5
0

NCS
3 ..-4
0

m
2
1
0

Q m3/h

2
466

NCS3

Circulating pumps for sanitary hot water

Characteristic curves
6

NCS3 ...-50

NCS3 ...-40
5

3
3

Hm

Hm

2
1

3
0
Q m /h
l/min 10
0

l/s

80

1.5
20

0.2

2.5
40

30

0.3

0.4

0.5

0.6

3
50

0.7

3.5

0.8

0.9

100

60

l/s

0.2

0.3

0.4

PW
60

2.5
40

0.5

0.6

0.7

3
50
0.8

3.5

0.9

2
1

40

20

0 Q m3/h

2
30

1.5
20

80

PW
40

3
0
Q m /h
l/min 10
0

1.5

2.5

20

3.5

Q m3/h

1.5

2.5

3.5

NCS3 ...-70
6

5
3

4
2

Hm
3
1

0
0

0
160

3
Q m /h
l/min 10

l/s

0.2

1.5
20

0.3

2.5

30
0.4

40

0.5

0.6

0.7

3.5

50
0.8

60
0.9

46

1.1

120

PW
80

40
0

0 Q m3/h

1.5

2.5

3.5

467

NCS3

Circulating pumps for sanitary hot water

Examples of installations

Dimensions and weights

DN

128
21

DN
80

107
49

Unions (on request)

TYPE

1x
P1 230 V a
(W)
[A] mm [kg]

DN

Pos.

NCS3 20-40/130
NCS3 25-40/130

G 1 1/4
G 1 1/2

3
2
1

70
59
41

0,30
0,26 130
0,18

NCS3 20-50/130
NCS3 25-50/130

G 1 1/4
G 1 1/2

3
2
1

91
65
42

0,38
0,28 130
0,18

2,5

NCS3 20-70/130
NCS3 25-70/130

G 1 1/4
G 1 1/2

3
2
1

148
128
87

0,66
0,59 130
0,41

3,8

Bocchettoni
Unions

DN

Rohrverschraubung

2,3

Manchons
Uniones

DN1

TIPO -TYPE
TYPE - TYP

KIT G 1 1/4 - G 3/4


KIT G 1 1/2 - G 1

468

DN

DN1

(NCS3 20..)

G 1 1/4

G 3/4

(NCS3 25..)

G 1 1/2

G1

NC3

Three speeds circulating pumps


with threaded ports

CANNOT BE SOLD IN THE EU


Construction
Pump casing with suction and delivery connections with the same
diameter and on the same axis (in-line).
Brass or cast iron unions on request.
Materials
Pump casing
Impeller
Shaft

NC3 ..40-50-60
Cast iron
Composite
Stainless steel

Installation

NC3 ...70-80-85-120
Cast iron
Composite
Ceramic

Applications
For clean liquids, without abrasives, which are non-aggressive for the
pump materials.
Civil and industrial heaty sistems.

Unions
Bocchettoni

Operating conditions

Rohrverschraubung

Unions
Manchons

Liquid temperature from +5 C to +110 C (from -10 C to +110 C


for NC3 ..-70 and NC3 ..-80-85-120).
Ambient temperature up to 40 C.
Sound pressure 43 dB (A).
Maximum glycol quantity: 50% (Mixture with more than 20% glycol
content require recheking of the pumping data).
Maximum permissible working pressure 10 bar.

TYPE

Uniones

0,05

0,4

0,05

0,4

1,1

NC3 ..-80,85,120

0,05

0,4

1,2

2-pole induction motor, 50 Hz.


Three adjustable speeds.
NC3: single-phase 230 V.
Insulation class H.
Protection IP 44.

DN

DN1

G 1/2

KIT G 1 - G 1/2

(NC3 15..)

G1

KIT G 1 1/2 - G 1

(NC3 25..)

G 1 1/2

G1

KIT G 2 - G 1 1/4

(NC3 32..)

G2

G 1 1/4

46

1,1

NC3 ..-70

Motor

DN1

TIPO - TYPE
TYPE - TYP

Minimum suction pressure: bar


Temperature
50 C
80 C
110 C

NC3 ..-40,50,60

DN

Designation
Series
DN ports in mm
Max. head in dm
connection size mm

469

NC3 32 - 70 / 180

NC3

Three speeds circulating pumps


with threaded ports

Characteristic curves, dimensions and weights


6

NC3 ...-50

NC3 ...-40
5

4
3

Hm

Hm

2
1

60

3
0
Q m /h
l/min 10
0

l/s

1.5
20

0.2

0.3

2.5
40

30
0.4

0.5

0.6

3
50

0.7

0.8

3.5

0.9

100

3
0
Q m /h
l/min 10
0

l/s

1.5
20

0.2

0.3

0.4

0.5

0.6

3
50

0.7

0.8

3.5

0.9

50

80

PW
40

PW
60

2
1

30
20

2.5
40

30

40

0 Q m3/h

1.5

2.5

20

3.5

0 Q m3/h

1.5

2.5

DN

3.5

fM
h1

NC3 ...-60
5

a
3

3
Hm
2

DN
80

107

49

TYPE
0

0
0

100

Q m /h
l/min 10
l/s

0.2

1.5
20

0.3

2.5

30
0.4

40

0.5

0.6

0.7

NC3 15-40/130 G 1
NC3 25-40/130 G 1 1/2
NC3 25-40/180 G 1 1/2

3.5

50
0.8

0.9

NC3 15-50/130 G 1
NC3 25-50/130 G 1 1/2
NC3 25-50/180 G 1 1/2
NC3 32-50/180 G 2
NC3 15-60/130 G 1
NC3 25-60/130 G 1 1/2
NC3 25-60/180 G 1 1/2
NC3 32-60/180 G 2

80
2

PW
60
1

40
20

0 Q m3/h

1.5

2.5

DN

3.5

470

1x
P1 230 V
Pos. (W) [A]

mm
a

fM

h1 [kg]

3
2
1

53 0,23 130 128 21 2,2


47 0,21 130 135 28 2,4
38 0,17 180 135 28 2,6

3
2
1

130 128
91 0,38
130 135
65 0,28
42 0,18 180 135
180 138

21 2,2
28 2,4
28 2,6
31 3

3
2
1

130 128
95 0,41
130 135
70 0,30
44 0,20 180 135
180 138

21 2,2
28 2,4
28 2,6
31 3

NC3

Three speeds circulating pumps


with threaded ports

Characteristic curves, dimensions and weights


8

NC3 ...-70

NC3 ...-80

3
3

40
3
3

1
1

DN

180

DN
80

TYPE

DN
NC3 25-70/180

G
1 1/2

NC3 32-70/180

G2

NC3 32-80/180

G2

P1
Pos. (W)

1x
230 V
[A]

[mm]
D

[kg]

3
2
1

136
116
77

0,61
0,54
0,37

135 107 49

2,9

3
2
1
3
2
1

136
116
77

0,61
0,54
0,37

138 107 49

3,1

206
185
120

0,91
0,88
0,60

185 143 58

4,7

471

46

NC3

Three speeds circulating pumps


with threaded ports

Characteristic curves, dimensions and weights


8

NC3 ...-85

NC3 ...-120

3
2

1
1

40

2
1

DN

180

DN
80

TYPE

DN

Pos.

G2

3
2
1

NC3 32-120/180 G 2

3
2
1

NC3 32-85/180

P1
(W)
277
250
172
265
251
176

472

1x
230 V
[A]

[mm]
B

1,2
1,16 185 143 58
0,85
1,15
1,14 208 174 68
0,85

[kg]
4,9

5,2

40

NCD3

Three speeds circulating twin pumps


with threaded ports

CANNOT BE SOLD IN THE EU


Construction

Operation

Pump casing with suction and delivery connections with the same
diameter and on the same axis (in-line).
Brass or cast iron unions on request.
Materials
Pump casing
Impeller
Shaft

NCD3 ..40
Cast iron
Composite
Stainless steel

NCD3 ...70-80-120
Cast iron
Composite
Ceramic

Applications
For clean liquids, without abrasives, which are non-aggressive for the
pump materials.
Civil and industrial heaty sistems.

Single operation
Operation of a single pump choosed by the customer, with the
second pump on stand-by

Double operation
Operation in parallel of the
two pumps

Installation

Operating conditions
Liquid temperature from +5 C to +110 C (from -10 C to +110 C
for NCD3 ..-70 and NCD3 ..-80-120).
Ambient temperature up to 40 C.
Sound pressure 43 dB (A).
Maximum glycol quantity: 50% (Mixture with more than 20% glycol
content require recheking of the pumping data).
Maximum permissible working pressure 10 bar.

type

Unions
DN

Minimum suction pressure: bar


Temperature
50 C
80 C
110 C

NCD3 ..-40

0,05

0,4

1,1

NCD3 ..-70

0,05

0,4

1,1

NCD3 ..-80,120

0,05

0,4

1,2

DN1

TYPE
KIT G 2 - G 1 1/4

Motor

Designation

2-pole induction motor, 50 Hz.


Three adjustable speeds.
NCD3: single-phase 230 V.
Insulation class H.
Protection IP 44.

Series
DN ports in mm
Max. head in dm
connection size mm

473

(NC3D 32..)

DN

DN1

G2

G 1 1/4

NCD3 32 - 70 / 180

46

NCD3

Three speeds circulating twin pumps


with threaded ports

Characteristic curves, dimensions and weights


4,5

NCD3 32-40/180

NCD3 32-70/180

3
1

60

30

10

10

3
2

20

40
1

10

20

0
0

Single operation
Operation in parallel

Single operation
Operation in parallel

237

87
180
80

DN

30

1x
230 V
[A] [kg]

DN

Pos.

P1
(W)

NCD3 32-40/180

G2

3
2
1

53
47
38

0,23
0,21
0,17

5,6

NCD3 32-70/180

G2

3
2
1

136
116
77

0,61
0,54
0,37

TYPE

110

474

NCD3

Three speeds circulating twin pumps


with threaded ports

Characteristic curves, dimensions and weights

NCD3 32-80/180

NCD3 32-120/180

2
8

1
1

10

14

10

40

14

30

3
2

20

10

10

14

Single operation
Operation in parallel

10

14

Single operation
Operation in parallel

256

87
180
80

DN

40
TYPE

1x
P1 230 V
DN Pos. (W)
[A] [kg]

NCD3 32-80/180

G2

3
2
1

NCD3 32-120/180

G2

3
2
1

145

475

206
185
120
265
251
176

0,91
0,88 9,6
0,6
1,15
1,14 10,3
0,85

46

NC

Three speeds circulating pumps


with flanges

CANNOT BE SOLD IN THE EU


Installation

Construction
Pump casing with suction and delivery connections with the same
diameter and on the same axis (in-line).
Materials:
Pump casing
Cast iron
Impeller
Stainless steel
Shaft
Stainless steel

Applications

Cross section drawings

For clean liquids, without abrasives, which are non-aggressive for the
pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required.

Operating conditions
Liquid temperature from -10 C to +120 C (in short-time duty up to
+ 140 C).
Ambient temperature up to 40 C.
Maximum glycol quantity: 50% (Mixture with more than 20% glycol
content require recheking of the pumping data).
Maximum permissible working pressure 6/10 bar.

TYPE
NC 40
NC 50
NC 65
NC 80

Minimum suction pressure: bar


Temperature
50 C
80 C
110 C
0,05
0,8
1,4
0,3
1
1,6
0,3
1
1,6
0,3
1
1,6

Designation

Motor

Series
Single-phase motor
4-pole motor
DN ports in mm
Max. head in dm
connection size mm

2-4-pole induction motor, 50 Hz.


Three adjustable speeds.
NC: three-phase 230V or 400 V.
NCM: single-phase 230 V.
Insulation class H.
Protection IP 43.

476

NC ( M ) 4 4 0 - 6 0 / 2 5 0

NC

Three speeds circulating pumps


with flanges

Coverage chart
13
12
11
10

m
8
NC 40-120

NC 65-120

NC 50-120

NC

NC 80-120

6
5
NC 40-60

NC4 50-60

NC4 80-60

NC4
65-60

NC4 40-40

1
0

NC4 50-40

Q m3/h 10

NC4 65-30

20

30

40

50

60

68

Tolerances in accordance with UNI EN ISO 9906:2012

13
12
11
10

m
8

NCM

NCM 40-120

NCM 50-120

6
5
4
NCM 40-60

46

NCM4 50-60

1
0

Q m3/h 5

10

15

20

25

30

35

Tolerances in accordance with UNI EN ISO 9906:2012

477

NC 40

Three speeds circulating pumps


with flanges

Characteristic curves, dimensions and weights

NC4 40-40/250

NC 40-60/250

3
2

2
1

110 (PN 10)


Nr. 4 19

150 40

NC 40-120/250

100 (PN 6)
Nr. 4 14

R 1/4
2

250

R 1/4
130

92

TYPE

DN PN
3

478

198

N
Poli
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

NC4 40-40/250/A 40 6/10

3
2
1

1440
1200
660

240
160
100

0,76
0,24 17,0
0,11

NC 40-60/250/A

40 6/10

3
2
1

2790
2240
1440

320
240
140

0,74
0,36 17,5
0,18

NC 40-120/250/A 40 6/10

3
2
1

2820
2200
1250

560
400
220

1,16
0,64 19,0
0,26

2
1

65

NCM 40

Three speeds circulating pumps


with flanges

Characteristic curves, dimensions and weights

NCM 40-60/250

NCM 40-120/250

3
2

3
2

1
1

3
2

2
1
1

110 (PN 10)


Nr. 4 19

150 40

100 (PN 6)
Nr. 4 14

R 1/4

250

R 1/4
130

92

65

198

N
Poli
2 4 Pos. 1/min

P1
(W)

1x
230 V
[A] [kg]

NCM 40-60/250/A 40 6/10

3
2
1

2690
2360
1820

285
245
225

1,20
1,18 17,5
1,15

NCM 40-120/250/A 40 6/10

3
2
1

2750
2100
1270

550
475
355

2,35
2,30 19,0
1,85

TYPE

DN PN

479

46

NC 50

Three speeds circulating pumps


with flanges

Characteristic curves, dimensions and weights

NC4 50-40/280

NC4 50-60/280
3

3
2

3
3

2
1

125 (PN 10)


Nr. 4 19

165 50

110 (PN 6)
Nr. 4 14

NC 50-120/280
3

R 1/4

280

R 1/4
1

130

113

P1
(W)

3x
400 V
[A] [kg]

NC4 50-40/280/A 50 6/10

3
2
1

1450
1220
620

340
240
120

1,05
0,44 24,0
0,22

NC4 50-60/280/A 50 6/10

3
2
1

1400
1000
560

470
300
100

1,15
0,55 24,0
0,20

NC 50-120/280/A 50 6/10

3
2
1

2800
2330
1270

950
540
265

1,73
1,05 24,0
0,46

DN PN

480

250

N
Poli
2 4 Pos. 1/min

TYPE

70

NCM 50

Three speeds circulating pumps


with flanges

Characteristic curves, dimensions and weights

NCM4 50-60/280

NCM 50-120/280

125 (PN 10)


Nr. 4 19

165 50

110 (PN 6)
Nr. 4 14

R 1/4

280

R 1/4
130

TYPE

113

70

N
Poli
DN PN 2 4 Pos. 1/min

250

P1
(W)

1x
230 V
[A] [kg]

NCM4 50-60/280/A 50 6/10

3
2
1

1260
1030
740

415
300
230

1,8
1,3
1,0

24,5

NCM 50-120/280/A 50 6/10

3
2
1

2720
1870
1450

830
480
390

3,6
2,1
1,7

24,5

481

46

NC 65

Three speeds circulating pumps


with flanges

Characteristic curves, dimensions and weights

NC4 65-30/340

NC4 65-60/340

2
2

1
1

3
2

2
1

145 (PN 10)


Nr. 4 19

185 65

130 (PN 6)
Nr. 4 14

NC 65-120/340
3

R 1/4
2

340

R 1/4

130

TYPE

123

252

N
Poli
DN PN 2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

NC4 65-30/340/A 65 6/10

3
2
1

1430
1150
600

400
260
120

1,10
0,50 29,0
0,22

NC4 65-60/340/A 65 6/10

3
2
1

1370
950
450

600
360
120

1,25
0,64 29,0
0,22

NC 65-120/340/A 65 6/10

3
2
1

2810 1560
2200 960
1250 460

2,80
1,70 31,0
0,84

482

80

NC 80

Three speeds circulating pumps


with flanges

Characteristic curves, dimensions and weights

NC 80-120/360

NC4 80-60/360

2
2

1
1

3
2

2
1

160 (PN 10)


Nr. 8 19
200 80

R 1/4

360

R 1/4
130

130

100

TYPE

DN PN

257

N
Poli
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

1350
1000
600

960
560
200

2,20
1,10 33,5
0,38

2800
2160
1200

2200
1400
550

3,80
2,40 34,5
1,05

NC4 80-60/360/A 80

10

3
2
1

NC 80-120/360/A 80

10

3
2
1

483

46

NCD

Three speeds circulating twin pumps


with flanges

CANNOT BE SOLD IN THE EU


Construction

Operation

Pump casing with suction and delivery connections with the same
diameter and on the same axis (in-line).
Materials:
Pump casing
Cast iron
Impeller
Stainless steel
Shaft
Stainless steel

Applications

Single operation
Operation of a single pump choosed by the customer, with the
second pump on stand-by

For clean liquids, without abrasives, which are non-aggressive for the
pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required.

Double operation
Operation in parallel of the
two pumps

Installation

Operating conditions
Liquid temperature from -10 C to +120 C (in short-time duty up to
+ 140 C).
Ambient temperature up to 40 C.
Maximum glycol quantity: 50% (Mixture with more than 20% glycol
content require recheking of the pumping data).
Maximum permissible working pressure 6/10 bar.

TYPE
NCD 40
NCD 50
NCD 65
NCD 80

Cross section drawings

Minimum suction pressure: bar


Temperature
50 C
80 C
110 C
0,05
0,8
1,4
0,3
1
1,6
0,3
1
1,6
0,3
1
1,6

Designation
Series
Twin pumps version
Single-phase motor
4-pole motor
DN ports in mm
Max. head in dm
connection size mm

Motor
2-4-pole induction motor, 50 Hz.
Three adjustable speeds.
NCD: three-phase 230V or 400 V.
NCDM: single-phase 230 V.
Insulation class H.
Protection IP 43.

484

NC D ( M ) 4 4 0 - 6 0 / 2 5 0

NCD

Three speeds circulating twin pumps


with flanges

Coverage chart
13
12
11
10

m
8
NCD 40-120

NCD 50-120

NCD

NCD 80-120

NCD 65-120

6
5
NCD 40-60

NCD4 50-60

NCD4 80-60

NCD4
65-60

NCD4 40-40

1
0

NCD4 50-40

Q m3/h

20

30

NCD4 65-30

40

50

60

70

80

90

100

110

120

Tolerances in accordance with UNI EN ISO 9906:2012

13
12
11
10

m
8

NCDM

NCDM 40-120

NCDM 50-120

5
4
3

46

NCDM 40-60

2
1

NCDM4 50-60

0
0

Q m3/h

10

20

30

40

50

Tolerances in accordance with UNI EN ISO 9906:2012

485

NCD 40

Three speeds circulating twin pumps


with flanges

Characteristic curves, dimensions and weights

NCD4 40-40/250

NCD 40-60/250

3
3
2

2
1

Single operation
Operation in parallel

Single operation
Operation in parallel

NCD 40-120/250

110 (PN 10)


Nr. 4 19

150 40

100 (PN 6)
Nr. 4 14

R 1/4

2
130
250

110
346

62

TYPE

DN

PN

3
2

486

N
Poli
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

NCD4 40-40/250/A 40

6/10

3
2
1

1440
1200
660

240
160
100

0,76
0,24 34,0
0,11

NCD 40-60/250/A

40

6/10

3
2
1

2790
2240
1440

320
240
140

0,74
0,36 35,0
0,18

NCD 40-120/250/A 40

6/10

3
2
1

2820
2200
1250

560
400
220

1,16
0,64 35,0
0,26

Single operation
Operation in parallel

198

NCDM 40

Three speeds circulating twin pumps


with flanges

Characteristic curves, dimensions and weights

NCDM 40-60/250

NCDM 40-120/250

3
2

1
1

3
2

2
1

Single operation
Operation in parallel

Single operation
Operation in parallel

110 (PN 10)


Nr. 4 19

150 40

100 (PN 6)
Nr. 4 14

R 1/4

130
250
110
346

62

198

N
Poli
2 4 Pos. 1/min

P1
(W)

1x
230 V
[A] [kg]

40 6/10

3
2
1

2690
2360
1820

285
245
225

1,20
1,18 35,0
1,15

NCDM 40-120/250/A 40 6/10

3
2
1

2755
2100
1270

550
475
355

2,35
2,30 35,0
1,85

TYPE

DN PN
NCDM 40-60/250/A

487

46

NCD 50

Three speeds circulating twin pumps


with flanges

Characteristic curves, dimensions and weights

NCD4 50-40/280

NCD4 50-60/280

3
3

3
2

2
1

Single operation
Operation in parallel

Single operation
Operation in parallel

125 (PN 10)


Nr. 4 19

NCD 50-120/280
165 50

110 (PN 6)
Nr. 4 14

R 1/4
2

130
280
1

121
400

70

TYPE

DN
3

PN

Single operation
Operation in parallel

488

N
Poli
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

NCD4 50-40/280/A 50

6/10

3
2
1

1450
1220
620

340
240
120

1,05
0,44 44,0
0,22

NCD4 50-60/280/A 50

6/10

3
2
1

1400
1000
560

470
300
100

1,15
0,55 44,0
0,20

NCD 50-120/280/A 50

6/10

3
2
1

2800
2330
1270

950
540
265

1,73
1,05 44,0
0,46

2
1

250

NCDM 50

Three speeds circulating twin pumps


with flanges

Characteristic curves, dimensions and weights

NCDM4 50-60/280

NCDM 50-120/280
3

2
1

Single operation
Operation in parallel

Single operation
Operation in parallel

125 (PN 10)


Nr. 4 19

165 50

110 (PN 6)
Nr. 4 14

R 1/4

130
280
121
400

TYPE

70

250

N
Poli
DN PN 2 4 Pos. 1/min

P1
(W)

1x
230 V
[A] [kg]

NCDM4 50-60/280/A 50 6/10

3
2
1

1260
1030
740

415
300
230

1,8
1,3
1,0

44,0

NCDM 50-120/280/A 50 6/10

3
2
1

2720
1870
1450

830
480
390

3,6
2,1
1,7

44,0

489

46

NCD 65

Three speeds circulating twin pumps


with flanges

Characteristic curves, dimensions and weights

NCD4 65-30/340

NCD4 65-60/340
3

1
1

3
3
2

2
1

Single operation
Operation in parallel

Single operation
Operation in parallel

NCD 65-120/340

110 (PN 10)


Nr. 4 19

185 65

100 (PN 6)
Nr. 4 14

R 1/4
2

130
340
1

141
450

80

TYPE

DN

Single operation
Operation in parallel

490

PN

252

N
Poli
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

NCD4 65-30/340/A 65

6/10

3
2
1

1430
1150
600

400
260
120

1,10
0,50 49,0
0,22

NCD4 65-60/340/A 65

6/10

3
2
1

1370
950
450

600
360
120

1,25
0,64 49,0
0,22

NCD 65-120/340/A 65

6/10

3
2
1

2810 1560
2200 960
1250 460

2,80
1,70 54,0
0,84

NCD 80

Three speeds circulating twin pumps


with flanges

Characteristic curves, dimensions and weights

NCD 80-120/360

NCD4 80-60/360

2
2

1
1

3
2

2
1

Single operation
Operation in parallel

Single operation
Operation in parallel

160 (PN 10)


Nr. 8 19
200 80

R 1/4

130
360
146
470

95

TYPE

257

N
Poli
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

DN

PN

NCD4 80-60/360/A 80

10

3
2
1

1350
1000
600

960
560
200

2,20
1,10 60,0
0,38

NCD 80-120/360/A 80

10

3
2
1

2800
2160
1200

2200
1400
550

3,80
2,40 62,0
1,05

491

46

492

09/2016

IDROMAT 5,6

Electronic regulator for pumps


Construction
Regulation device for pump control equipped with flow and pressure sensor connected to an electronic system.
Inlet and delivery connection ports of the same diameter.
Built-in check valve.
Pressure gauge 0-12 bar supplied as standard for IDROMAT 5..
(IDROMAT 6.. not present).
Automatic reset function for the reset of the system without
manual operation.

Applications
Automatic control of pumps for water supply and increase of
network pressure.
Control of starting/stopping of the pump when cocks are
opened/closed.
For protection of the pump:
against dry running;
against the risk of operation without water at the inlet (caused
by a lack of water inflow in the inlet pipe under positive suction head, by a non-immersed suction pipe, by excessive suctionlift or by air entering the suction pipe);
against operation with closed connection ports.

Operating conditions
Mains voltage: single-phase 230 V 10% Idromat 5e;
single-phase 115 - 240 V 5% for Idromat 5, 6.
Frequency: 50 - 60 Hz.
Current values:
- 8A max during operation (16A max at start-up) for IDROMAT 5;
- 16A max during operation (30A max at start-up) for IDROMAT 6
Maximum pump motor power 1,5 kW (2,2 kW for IDROMAT 6).
Protection: IP 65.
Maximum working pressure: 12 bar (1,2 MPa)
Maximum Operating temperature up to 65 C.
Minimum flow ~ 1 l/min.
Male connections 1 (1 1/4 for IDROMAT 6).

Operating conditions
TYPE
IDROMAT 5-12
IDROMAT 5-15
IDROMAT 5-22
IDROMAT 5-30
IDROMAT 6-15
IDROMAT 6-30
IDROMAT 5e

Switching-on
pressure

Pump
head

1,2 bar
1,5 bar
2,2 bar
3 bar
1,5 bar
3 bar

> 20 m
> 23 m
> 30 m
> 40 m
> 23 m
> 40 m

adjustable from 1,5 to 2,5 bar

(1)

Materials
Component
Housing
Membrane

IDROMAT 5-5e
Polyamide PA 6 G.F. reinforced
Natural rubber

(1) 1,5 bar more than the expected restart pressure

Comparison of pressure values

Diagram of head loss


30

H
H
m

Pump outlet head

B
20

10

47

Time
4.93.054

0
A = operation with IDROMAT = constant pressure;
B = operation with traditional vessel and pressure switch system.

0 Q m3/h

H = Head loss in meters

493

10

12

IDROMAT 5,6

Electronic regulator for pumps

Control Panel

Status indications and system reset


The three leds give the information about the system operativity, the first led indicates the presence of
supply, the second led indicates if the pump is operating and the third led indicates if an alarm has
occurred in the system. The Reset button allows to manually restart the system when an alarm occur.

Programming of the re-start pressure


The display allows to visualize the re-start pressure of the system, the buttons allow to change the re-start
pressure value.

Dimensions and weights


IDROMAT 5

190
60

kg 1,2

130

188
88

52

98

150,5

R1

140

R1

IDROMAT 6

251
66

kg 1,5

185

211

R 1" 1/4

151

175

60

Made in Italy

65 C max
IP 65
12 bar max

P607.a - REV00

P607.b- REV00

110V240V
50/60 Hz
30 (16) A max

R 1" 1/4

494

max 12 m
max 15 m
max 22 m
max 30 m

495
max 12 m
max 15 m
max 22 m
max 30 m
IDROMAT 6-15: max 15 m
IDROMAT 6-30: max 30 m

IDROMAT 5-12:
IDROMAT 5-15:
IDROMAT 5-22:
IDROMAT 5-30:

IDROMAT 6-15: max 15 m


IDROMAT 6-30: max 30 m

IDROMAT 5-12:
IDROMAT 5-15:
IDROMAT 5-22:
IDROMAT 5-30:

IDROMAT 5,6
Electronic regulator for pumps

Installation example

4.93.096
4.93.096/14

Foot valve
Check valve

47

IDROMAT 5,6

Electronic regulator for pumps

Features

Flexibility
The standard double supply voltage (only for Idromat 5 and 6) allows to connect
power supply of 115 - 240V without modifications on the device.

Easy to use
With the Idromat 5e it is possible to change the re-start pressure, the operation is
possible also with the pump that operate.

Safety
The device includes a automatic re-start system with anti-lock mode in order to
reduce the user operations.

Reliability
The pressure gauge locking system (patented) allows an easy replacement in
case of failure and an easy drainage of the device.

User friendly
The high luminosity leds allows a higher visibility of the operating conditions.

496

09/2016

EASYMAT

Variable speed system driven


by frequency converter
Construction

PATENTED

Variable speed system driven by frequency converter, for the


pressure control in domestic and residential plants.
The system is connected to the delivery pipe providing for simple
installation and better cooling (patented) making the unit more
compact and easy to assemble.
Easymat is supplied with one pressure transducer, G 1/4
connection and 1.5 m cable length.

Applications
Automatic frequency inverter control for use on pumps to
increase network pressure.
The system maintains constant pressure whilst the controlling
the pump operation against changing system demand.
For protection of the pumps:
Against dry running
Against operations with closed connection ports
Against overcurrent of the motor
Against overvoltage and undervoltage of the power supply

Operating conditions

Features
Constant pressure
The Easymat via a frequency inverter keeps the pressure constant as the flow
demand changes.

EASYMAT MM - Input voltage: 1~ 230V 10%


- Output voltage: 1~ 230V
EASYMAT MT - Input voltage: 1~ 230V 10%
- Output voltage: 3~ 230V
Input frequency: 50-60 Hz
Output frequency: up to 70 Hz
Protection: IP 55
Max Ambient temperature: 40C
Max liquid temperature: 40 C (50C for 5MM, 5MT)
Minimum Flow: 3 l/min
Altitude: no higher than 1000 m, inside a closed environment.

Construction
Energy saving
The variable speed operation ensures that only the energy required by the plant at
any instant is used.

System reliability
Because the easymat is independent of the pumped liquid it's operation is not
affected by fluid impurity.
A float switch can also be integrated to further protect against dry running.

(Standard execution)
The system comprises of:
- Frequency converter.
- Pressure transducer.
- Pipe housing.
- Fixing screws.
- Terminal board.
- Cable glands.
- Multi-hole gaskets.

Type
Flexibility
Thanks to it's patented design the easymat does not come into contact with the
pumped fluid. This provides for more flexibility during installation eliminating the
need for pipe-work modifications or the installation of isolating valves.

Type
(single-phase)

kW

0,37 - 0,55

9,2

0,75 - 1,5

Freqeuency converter
max
current output

Standard power
motor
230V

kW

0,75 - 1,1

Easymat 7,5MT

7,5

1,5 - 1,8

Easymat 9,2MT

9,2

2,2

Easymat 9,2MM

Type
(three-phase)

Cascade control mode


The system flexibility allows via a microprocessor for cascade operation of two
easymat's via one pressure transducer.

497

Standard power
motor
230V

A
Easymat 5MM

Easy to use
The easymat has a clear display making it very simple to set-up.

Freqeuency converter
max
current output

Easymat 5MT

48

EASYMAT

Variable speed system driven


by frequency converter

Control Panel
Easymat is equipped with a control panel for simple system programming and
parameter monitoring.
The 2 scroll buttons are used to scroll the different operating parameters that
EASYMAT can show.
At the same time you can use the 2 scroll buttons to move in the set up menu and to
change the different options.
The LCD custom display gives an easy overview of the system situation and of the
operating parameters.
The icons on the top and below the display area explain in which way EASYMAT is
working and if there are problems on the system.

P460

The four set-up buttons allow the operator to move between and set-up the menu's
and to start and stop the pump. The symbols help to make the function of each
button clear.
With these 4 buttons and the 2 scroll buttons you can manage all the set-up and
operating parameters without the use of an other control panel or computer.
4.93.410

Display LCD
The integrated LCD custom display
gives you an easy overview of the
system situation and operating parameters.

DISPLAY AREA
The display area gives the status of the
parameters of the pump.

The OPERATING ICONS show in which mode the system is operating:


Constant pressure mode
The system keeps the pressure constant when the quantity of water requested by the user changes.
The user can choose the operating pressure according his needs.
Fixed speed mode
The system works at a fixed speed that user can choose according his needs.

The SYSTEM ICONS show in which way the system is operating:


Auto Mode
The icon shows that the system is operating in auto mode (constant pressure mode), the constant pressure mode it is indicated by the icon
on the lower part of the display.
Manual Mode
The icon show that the system is operating in manual mode (fixed speed mode), with the navigation buttons the user can change the speed,
the fixed speed mode is indicated by the icon on the lower part of the display.
Set-up Mode
The icon shows that the set-up menu is activated, in this mode it is possible to change all the operating parameters of the EASYMAT.
With the navigations buttons it is possible to scroll the parameters and, if necessary, change them.
Sensor State
indicates the state of the pressure transducer connected to the EASYMAT, if lit it indicates that the pressure transducer is working, if it is
blinking there is a fault or a incorrect connection of the pressure transducer.
Alarm
It indicates that there is a fault on the system, the error number appears on the display area.
Cascade Mode
It indicates that the multi-pump mode (up to 2 pumps) is working, the upper icon shows if the pump connected with the frequency
converter is running or is in stand-by, the lower icon indicates if the pump is the master pump (the icon is lit) or the slave pump (the icon is
blinking).

498

EASYMAT

Variable speed system driven


by frequency converter

Overview
G 1 and G 1 1/4 aluminium
pipe housing (on request
G 1 1/2).

Electronic card with


protective coating.

Square cover making it


possible to fit in four
different positions.

High efficiency aluminium


heatsink.

Integrated control panel


with 6 buttons and LCD
display.

PATENTED

Dimensions and weights

190

kg 1,9

100

made in italy

190

Weight

48

499

EASYMAT

Variable speed system driven


by frequency converter

Installation example

One pump
installation scheme

Two pumps
installation scheme

Three pumps
installation scheme

4.93.412

2.91.092

.4

_1

4.93.412.6

Plant conversion scheme


Existing fixed speed version
With EASYMAT it is easy to create a variable speed system starting from a
existing fixed speed system without disturbing the existing pipe-work.

To create the variable speed system it is only necessary to:


- Disconnect the pressure switch from the system and, in the same
housing connect the pressure transducer.
- Connect EASYMAT to the pipe.
- Connect EASYMAT to electric motor.
- Connect the supply cable to the electric grid.

Variable speed system version

.2
4.93.412

.3

4.93.412

500

09/2016

VARIOMAT 2

Variable speed system driven


by frequency converter
Construction
Variable speed system driven by frequency converter, for the
pressure control in domestic and residential plants.
The unit more compact and easy to assemble.
Variomat 2 is supplied with integrated pressure transducer.
Connection ports are available with G 1 1/4 and G 1 1/2
thread and are interchangeable.

Applications
Automatic frequency inverter control for use on pumps to
increase network pressure.
The system maintains constant pressure whilst the controlling
the pump operation against changing system demand.
For protection of the pumps:
Against dry running
Against operations with closed connection ports
Against overcurrent of the motor
Against overvoltage and undervoltage of the power supply

Operating conditions
Standard voltage: 400 V 10% (380-415V) three-phase
Max working pressure: 16 bar.
Frequency: 50-60 Hz
Protection: IP 65
Max Ambient temperature: 60C
Max liquid temperature up to 60 C
Minimum Flow: 1 l/min
Altitude: no higher than 1000 m, inside a closed environment.

Construction
Features
Constant pressure
The Variomat 2 via a frequency inverter keeps the pressure constant as the flow
demand changes.
Energy saving
The variable speed operation ensures that only the energy required by the plant at
any instant is used.

(Standard execution)
The system comprises of:
- Frequency converter.
- Pressure transducer.
- Pipe housing.
- Fixing screws.
- Terminal board.
- Cable glands.
- Multi-hole gaskets.

Type

System reliability
A float switch can also be integrated to further protect against dry running.

Type
(single-phase)

Easy to use
The Variomat 2 has a clear display making it very simple to set-up.
Cascade control mode
The system flexibility allows via a microprocessor for cascade operation of two
variomat's.

Freqeuency converter Standard power


max
motor
current output
400V
A

kW

VARIOMAT VTT2/A 9

0,75 - 3

VARIOMAT VTT2/A 12

12

4 - 5,5

VARIOMAT VTT2/A 16

16

7,5

Dimensions and weights


260
kg 5
PRESSURE

CURRENT

SET POINT PRESSURE

bar

bar

RESTART PRESSURE

bar

P529

Serial Number

308

made in italy

49

VARIOMAT 2 - 9TT
IN:

3 ~ 400V 50/60 Hz

OUT: 3 ~ 400V 50/60 Hz max 9A


Tmax: 60C IP65 Pmax 12 bar

P530

Weight

P531

148

136
284

501

VARIOMAT 2

Variable speed system driven


by frequency converter

Control Panel
PRESSURE

CURRENT

SET POINT PRESSURE

bar

RESTART PRESSURE

bar

bar

P529

Serial Number

Status indications and system reset


The three leds give the informations about the system operativity, the first led indicates the presence of
supply, the second led indicates if the pump is operating and the third led indicates if an alarm has
occurred in the system. The Reset button allows to manually restart the system when an alarm occur.

Programming of the nominal current and absorbed current display


The 2 digit display allows to visualize the nominal motor current (in programming mode) , during the operating time of the system the display visualizes the line absorbed current. The buttons allow to set and
change the nominal motor current.

Pressure display and start/stop of the frequency converter


The display allows to visualize the operating pressure of the system, the buttons allow to start and stop
manually the frequency converter.

Programming of the set-point pressure


The display allows to visualize the set-point pressure of the system, the buttons allow to change the
set point pressure value.

Programming of the re-start pressure


The display allows to visualize the re-start pressure of the system, the buttons allow to change the re-start
pressure value.

Installation example
One pump installation scheme

SET POINT PRESSURE

bar

bar

RESTART PRESSURE

bar

P529

Serial Number

PRESSURE

CURRENT

SET POINT PRESSURE

bar

made in italy

bar

Serial Number

RESTART PRESSURE

PRESSURE

CURRENT

bar

SET POINT PRESSURE

bar

bar

Serial Number

VARIOMAT 2 - 9TT
IN:

3 ~ 400V 50/60 Hz
P530

OUT: 3 ~ 400V 50/60 Hz max 9A

made in italy

made in italy

P531

VARIOMAT 2 - 9TT

VARIOMAT 2 - 9TT

3 ~ 400V 50/60 Hz

IN:

OUT: 3 ~ 400V 50/60 Hz max 9A


Tmax: 60C IP65 Pmax 12 bar

502

3 ~ 400V 50/60 Hz

OUT: 3 ~ 400V 50/60 Hz max 9A


Tmax: 60C IP65 Pmax 12 bar

P531

P530

IN:

P530

Tmax: 60C IP65 Pmax 12 bar

RESTART PRESSURE

bar

P529

P529

PRESSURE

CURRENT

Two pumps installation scheme

P531

09/2016

I-MAT

Variable speed system driven


by frequency converter
Construction
Variable speed system driven by frequency converter for the
motor control in the water supply applications and in the production/distribution of hot/cold water.
I-MAT is an integrated control system which, applied to the motor,
allows to manage a wide range of applications and operating
modes.

Applications
Frequency converter for automatic pump control suitable for:
- water supply
- water transport and distribution
- production and distribution of hot/cold water
- water treatment
For protection of the pumps:
- Against dry running
- Against operations with closed connection ports
- Against overcurrent of the motor
- Against overvoltage and undervoltage of the power supply
- Against unbalance or missing supply phases.

Operating conditions

Benefits
Flexibility
I-MAT frequency converters are equipped with a software which provide different
operating modes in order to cover a wide range of applications.

Reliability
The high efficiency heatsink with integrated fans allows to cool the frequency
converter independently from the motor, to provide a higher reliability of the system.

Safety
The shape of the I-MAT frequency converters allows to separate the signal
terminals area, from the power terminals area, in this way the user can operate on
the signals connections in safety conditions.

Easy to use
The integrated control panel allows to program all the parameters directly on the
frequency converters. Moreover its possible to remove the control panel and
remote it with a connection cable.

Standard voltage: 400 V 10% (380-415V) three-phase


Input voltage: 3~380V-10% 3~480V+5%
Output voltage: 0 100% of the input voltage
Input frequency: 50-60 Hz
Output frequency: up to 70 Hz
Protection: IP55
Max Ambient Temperature: 50C
Altitude: no higher than 1000 m, inside closed environment.

Construction
(standard execution)
The system comprises of:
- Frequency converter
- Removable control panel
- Power terminal board
- Signals terminal board
- Cable glands
On request:
- Adapter for motor mounting
- Adapter for wall mounting
- Pressure and temperature transducer
- Main switch
- Line filter and output filter

Type
Type
(three-phase)

Communications between units


The system flexibility allows, with an optional electronic card, to assemble more
units making them communicate together. The system is capable to manage
variable speed pumps (up to 6) and fixed speed pump (up to 5).

503

I-MAT 5,2 TT-A

Freqeuency converter Standard power


max
motor
current output
400V
A

kW

5,2

0,55 1,8

I-MAT 11,2 TT-B

11,2

2,2 4

I-MAT 25,8 TT-C

25,8

5,5 11

50

I-MAT

Variable speed system driven


by frequency converter

Operating modes
Constant pressure mode
Constant pressure keeps the pressure constant at a fixed value set by the user. This value of pressure is automatically kept by the system
to provide to the final user a constant pressure even with different water demand, within the maximum performance of the motor-pump
system.
Proportional pressure modes
Proportional pressure reduces the pressure of the pump (and as a consequence, the operating frequency) proportionally with the water
demand of the system.

Constant temperature mode


In this operating mode the system is used to keep the temperature at a constant value in a specified system point.

Constant flow mode


Constant flow mode grants that system change the speed of the pump in order to keep constant the flow which pass inside a flow meter.

Fixed speed mode


In this operating mode the system work as a fixed speed pump. The speed of the pump could be set by the user between a range of speeds,
or controlled by an external signal.

Night mode
The night mode is an optional mode which allows to reduce the speed of the pump if the temperature in the system decreases below a set
value, this operating mode can be used with all operating modes over described.

Control Panel

I-MAT is equipped with a control panel that allows to carry out the set-up of the
system and to monitor all system parameters.
The control panel is inside a IP55 enclosure which is possible to rotate and install
in remote positions.
It is possible use the control panel in remote positions by means a cable with M12
connectors (standard cable).
The LCD custom display gives an easy overview of the system situation and of
the operating parameters.
The icons on the top and below the display area explain in which way i-MAT is
working and if there are some problems on the system.
The 2 scroll buttons are used to scroll the different operating parameters that iMAT can show. At the same time you can use the 2 scroll buttons to move in the
set up menu and to change the different options.
The 4 set-up buttons are created to enter and to move on the set-up menus and
to start and to stop the pump. The symbols help to understand the function of
each button. With these 4 buttons and the 2 scroll buttons you can manage all the
set-up and operating parameters without the use of another control panel or
computers.

504

I-MAT

Variable speed system driven


by frequency converter

Overview

Control panel
The integrated control panel gives the customer the
possibility to set all the parameters of the frequency
converter.

Main switch
The frequency converters have the possibility (optional) to install a main switch.

Optional modules
On the front side of the frequency converter are
predisposed compartments for connecting the
optional modules. This solution allows to install
the modules without dismantling the frequency
converter.

I/O connection area


The connection area for the input/outputs is
separated from the power connection area, this
solution allows to connect external.

Power connection area


The connection area is protected by a safety
cover, there are dedicated clamps to connect one
PTC probe.

Heatsink
The high efficiency heat sink cooled by fans guarantees
a high reliability. The side connection system allows an
easy connection with the motors.

50

505

I-MAT

Variable speed system driven


by frequency converter

Installation example

One pump installation scheme

MXH EI

NM EI

NR EI

MXV EI

Two pumps installation scheme

2MXH

2NM

506

2MXV

09/2016

Pressure Boosting Sets


Fixed speed pump units
Variable speed pump units with frequency converter

51

507

Index
page 514

page 572

MINIMAT, TURBOMAT
CENTRIMAT, GETTOMAT

Fixed speed pump pressure


boosting sets for civil use
with 1-2-3 MXH

Small automatic water systems


with 1 pump series
MXH, MGP, MXP, NM, NG, MXA
NGL, NGX

BS1V.F, BS.V
Variable speed pump pressure
boosting sets for civil use
with 1-2-3 MXH

page 524

page 579

EASYMAT

BS.F
Fixed speed pump pressure
boosting sets for civil use
with 1-2-3 MXSU

Constant pressure boosting sets


with Easymat frequency converter
with 1 or 3
MGP, MXP, MXH, MXSU, MXVB, 4SDF

BS1V.F, BS.V
Variable speed pump pressure
boosting sets for civil use
with 1-2-3 MXSU

page 536

page 584

VARIOMAT 2

BS.F
Fixed speed pump pressure
boosting sets for civil use
with 1-2-3 MXVB

Constant pressure boosting sets


with Variomat frequency converter
with 1 or 2
MXH, MXVB

BS1V.F, BS.V
Variable speed pump pressure
boosting sets for civil use
with 1-2-3 MXVB

page 541

page 591

I-MAT

BS.F
Fixed speed pump pressure
boosting sets for civil use
with 1-2-3 MXV

Constant pressure boosting sets


with I-MAT frequency converter
with 1 or 3
MXH, MXVB, MXV

page 559

BS .F

BS1V.F, BS.V
Variable speed pump pressure
boosting sets for civil use
with 1-2-3 MXV

page 599

BS2F
Fixed speed pump pressure
boosting sets for domestic use with 2
MGP, MXP, NM, NMD, NG, NGL, NGX

BS.F
Fixed speed pump pressure
boosting sets for civil use
with 1-2-3 NM, NMD

BS1V1F, BS2V

BS1V.F, BS.V

Variable speed pump pressure


boosting sets for domestic use with 2
MGP, MXP, NM, NMD

Variable speed pump pressure


boosting sets for civil use
with 1-2-3 NM, NMD

TO SELECT A PRESSURE BOOSTING SET


508

page 651

Pressure Boosting Sets


Designation
CENTRIMAT 1/1 MXH 205E /20
CENTRIMAT MXH 205E /24
Tank capacity (litres)
Pump type
With tank under the pump
(no indication: tank above the pump)
Product series

BS M 2V
2 MXV 25/204 - I TT
BS M 1V 1F 2 MXV 25/204 - E MM
BS M
2F 2 MXV 25/204

T Three-phase motor
M Sigle-phase motor

Pump type
Nr of pumps

1F
2F
3F
1V1F
1V2F
1V
2V
3V

T Three-phase supply
M Sigle-phase supply
E= EASYMAT series,
V= VARIOMAT 2 series,
I= I-MAT series

1 fixed speed pump


2 fixed speed pumps
3 fixed speed pumps
1 variable speed pump and 1 fixed speed pump
1 variable speed pump and 2 fixed speed pumps
1 variable speed pump
2 variable speed pumps
3 variable speed pumps
Sigle-phase supply
(no indication: three-phase supply)
Product series

51
To select a Pressure Boosting Set see chap. 55 technical appendix at page 664.
For booster sets with 4, 5 and 6 pumps contact our Technical Sales Department.
509

Operation
MINIMAT

BSF

Construction

Construction

Small pressure boosting sets with automatic operation, consisting of


pump, pressure switch and 1 litre diaphragm tank.

Pressure boosting sets with automatic operation, consisting in 2 and 3


pumps on a common baseplate, with sunction and delivery manifolds, gate
and non-return valves, pressure switches, pressure gauge, control panel
and from 100 to 1000 litres diaphragm tank (on request).

with 1 fixed speed pump

with 2 and 3 fixed speed pumps

BS
2F2F
BS

2 fixed
speed
pumps fissa
2 pompe
a velocit

1l

Operation
Pump is directly driven by the pressure switch.
MINIMAT
MINIMAT
1 fixed speed pump
1 pompa a velocit fissa

BS
BS3F
3F

33 fixed
speed
pumpsfissa
pompe
a velocit

H
m

Stop
Start

Operation

Q m 3/h

The control panel, with electronic card, manages the pump operation, the
changeover of pump starting sequence and it stops the system when there
is no air in the tank (patented system).
Pumps starting in a cascade sequence, with a signal from the pressure
switches.

TURBOMAT, CENTRIMAT, GETTOMAT

with 1 fixed speed pump

Construction
Small pressure boosting sets with automatic operation, consisting of with
pump, pressure switch, pressure gauge and diaphragm tank (24litres if
above the pump, 20litres if under the pump).

BS
2F2F
BS

2 fixed
speed
2 pompe
a pumps
velocit fissa

H
m
24 l

F
Stop
Start

Operation
Pump is directly driven by the pressure switch..
Q m 3/h
BS
3F3F
BS

TURBOMAT, CENTRIMAT,
TURBOMAT,
CENTRIMAT,GETTOMAT
GETTOMAT

3 fixed
speed
3 pompe
a pumps
velocit fissa

1 fixed speed pump


1 pompa
a velocit fissa

H
m

H
m

Stop

Stop

Start

Start

Q m 3/h

Q m 3/h

510

BSV
2-6 variable speed pumps (with frequency converter)

BSV.F.
1 variable speed pump (with frequency converter)
1 to 5 fixed speed pumps

Construction
Pressure boosting sets with automatic operation, consisting of
variable speed pumps (from 1 to 6) with frequency converter on
the control panel, assembled on a common baseplate, with suction and delivery manifolds, gate and non-return valves, pressure transducer, pressure gauge, control panel and 20 litres
diaphragm tank (on request).

Construction
Pressure boosting sets with automatic operation, consisting of 1 variable
speed pump with frequency converter into the control panel and from 1 to
5 fixed speed pumps, assembled on a common baseplate, with suction
and delivery manifolds, gate and non-return valves, pressure gauge, control panel and 20 litres diaphragm tank (on request).
BS
BS1V1F
1V1F

BS
BS2V
2V

22variable
pumpsvariabile
pompespeed
a velocit

22pumps:
1variable
pompe:
1 variabile
1 fixed
1 fissa

BS
BS1V2F
1V2F

BS
BS3V
3V

33variable
pumpsvariabile
pompespeed
a velocit

32pumps:
1variable
pompe:
1 variabile
2 fixed
2 fisse

Operation

Operation
The control panel, with electronic card, manages the pump operation, the changeover of pumps starting sequence.
Pumps starting in a cascade sequence, with a signal from the
pressure transducer.

The control panel, with electronic card, manages the pump operation, the
changeover of fixed speed pumps starting sequence
Pumps starting is in a cascade sequence, with a signal from the pressure transducer.
Constant pressure is guaranteed by the variable speed pumps, while
fixed speed pumps start when the request is higher than the capacity of
the variable speed pump.

BS
BS2V2V

BSBS
1V1F
1V1F

22variable
speed
pumps variabile
pompe
a velocit

2 pumps:
1variable
2 pompe:
1 variabile
1 fixed1 fissa

H
m

H
m

H set

H set

Q m 3/h

Q m 3/h

BSBS
1V2F
1V2F

BS
BS3V3V

33variable
speed
pumps
pompe
a velocit
variabile

3 pumps:
1variable
3 pompe:
1 variabile
2 fixed 2 fisse

H
m

H
m

51
H set

H set

Q m 3/h

Q m 3/h

511

Pressure Boosting Sets


Fixed speed pump units
New electrical control panels
for fixed speed pump units.

New electrical control panels for pressurisation units, all with


electronic card with microprocessors, for managing pump
operation.

The microprocessor carries out continuous secure checks during


all the various work phases of the pumps and incorporates all
necessary functions, thus reducing electrical and electronic
components inside the panel.

In particular:
- pumps starting in a cascade sequence according to water
demand.
- changeover of pump starting sequence.
- delay start-up of the 2nd/3rd pump in case of breakdown of
pressure switch 1 or after a power cut.
- avoid pump starting in case of water hammering.
- activate the alarm when pressure 1 fails.
- activate the alarm when air cushion in the vessel drops.
- stop the pump when air cushion is over*.
* Patent pending

Maximum clarity for all signals


The status of the unit can easily be identified on the front of the
electronic card with the following signals:
- Power on led.
- No water led.
- Failure led.
- Pump running led (1 for each pump).
- Thermal block led (1 for each pump).
- Pump automatic operation led (1 for each pump).
- Pump stop led (1 for each pump).

Maximum simplicity of control


The front of electronic card features the following signals and controls:
- AUT-STOP push-button (1 for each pump)
- MAN push-button (1 for each pump)
- RESET push-button.

Optional remote control


The new panels have been designed to remotely reproduce all the electronic card signals (excluding the buttons), using RC 100 - RC 200 - RC 300
panels, connected with a simple two-pole cable.
The RA 100 panel enables a remote warning light and acoustic signal.

Control panel for units up to 6 pumps


Using the MPS 6000 (Multi Pumps System) electronic card it is possible to control pressure units up to a maximum of 6 fixed speed pumps with a
single pressure calibration.

Automatic air supply systems


The pump control panels are completed by microprocessor controlled systems for automatic air supply in the pressure vessels by means of a
compressor or solenoid valve.

Operation

For booster sets made up to three pumps: according to the pressure decrease in the system, the pressure switches make the pumps to start in
cascade mode and the starting changeover is made by the microprocessor.
For sets made of 4, 5, 6 pumps: Operation controlled by a microprocessor with signal from a pressure transducer. The pumps operate with only one
pressure setting.

512

Pressure Boosting Sets


Variable speed pump units with frequency converter
New electrical control panels
for variable speed pump units.

New electrical control panels for pressurisation units with variable


speed pumps.
These are indispensible in all those cases where constant pressure
is required and when high pressure pumps are being controlled.
All the various working phases are managed and controlled by the
MPS 6000 (Multi Pumps System) electronic card with microprocessor, which can operate up to 6 pumps working simultaneously.

Maximum clarity of signals


All the various calibration parameters appear as messages on the
display of the MPS 6000 electronic card.
If there are any faults or defects a message appears on the display
giving details of the problem.

Possibility of remote control


The pump status can be displayed and the unit can be controlled by
means of a special computer program.
It is possible to obtain a remote warning light and acoustic signal on
the RA 100 panel.

Constant or increased pressure


All the pumps can work with the same pressure value (set point), or, for
systems with high head losses, the pressure can be increased
depending on the number of pumps operating.

Silent operation
Motors working at reduced speed and check valves that close gradually mean that operation is particularly quite.

Long life for pumps


All the mechanical components of the pumps and motors are stressed to a minimum, due to the variable speed operation.

Energy savings
The motors consume only the precise level of power necessary moment to moment, in order to supply the quantity of water required by the system.

No more high capacity vessels


The use of inverters means that high capacity pressure vessels and membrane vessels are no longer necessary. Even units with high flowrate pumps
only require a small number of 20 litre membrane vessels.

Great versatility
The great versatility of the MPS 6000 electronic card enables the construction of special units with operational logics different from those of normal pressurisation units, depending on the requirements and characteristics of the systems.

Operation
Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the set
pressure.

51

513

MINIMAT - TURBOMAT - CENTRIMAT - GETTOMAT


Small automatic water systems

Construction
Compact, automatic autoclaves for household water feeding, consisting of:
- close-coupled pump
- membrane tank
- pressure switch
- pressure gauge (excluding MINIMAT)
- special connector
- flexible pipe for systems with pump over the vessel

Operation
According to the decrease or increase of pressure, the pressure switch determines when the pump will start or stop.

Applications
For drawing water out a well.
As pressure boosting pump for central water systems with thermal protector (follow specifications if increasing network pressure).

Motors
2-pole induction motors, 50 Hz, n 2900 rpm.
Three-phase 230/400V 10%.
Single-phase 230V 10%, with thermal protector.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.

Vessels
Spherical with capacity 24 litres, or cylindrical with capacity 20 litres, membrane type, air preordaining with pressure 0,2 bar below the minimum
pressure switch rating.
Capacity of the MINIMAT vessel 1 liter.

514

MINIMAT

Systems with liquid ring CA


and peripheral pumps CT

Coverage chart
0
0

U.S. g.p.m.

Imp.g.p.m.

10

50

160

CT 61
CA 80E

40

140

120

30

100

ft

80

CA 80E
20
60

CT 61

40
10
20

0
0
0

m3/h
Q l/min

0.5

1.5

10

20

2.5

2
30

40
72.852.C

Characteristic, dimensions and weights


MINIMAT
DN2

DN1

MINIMAT

4.93.108

MINIMAT
3~ 230/400V
CT 61/1
CA80E/1

1~ 230V
CTM 61/1
CAM 80E/1

kW HP
0,33 0,45
0,45 0,6

Q
max*
l/min
30
32

Pres. switch

bar
1,42,8
1,42,8

DN1
G1
G 3/4

DN2
G1
G1

mm
B
L
H
180 255 280
180 255 330

* Maximum pump flow at minimum set pressure of pressure switch.

kg
8
11,5

51

515

TURBOMAT

Systems with peripheral pumps


series T, TP

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

10

15

10

100

300

T - TP

80

H
ft

TP 80E
200

60

40

T 70/A

100

T 65E

20

T 61E
0

0
0
0

m3/h
l/min

2
20

40

60
72.940.C

Characteristic, dimensions and weights


TURBOMAT 1/1

TURBOMAT

DN2
TURBOMAT

TURBO

DN1

DN2
DN1

TURBOMAT 1/1

3.93.050

3.93.049

TURBOMAT
3~ 230/400V
T 61E/24
T 65E/24
T 70/A/24
TP 80E/24

kW HP
0,33 0,45
0,45 0,6
0,75 1
0,75 1

Q
max*
l/min
32
43
50
22

kW HP
0,33 0,45
0,45 0,6
0,75 1
0,75 1

Q
max*
l/min
32
43
50
22

1~ 230V
TM 61E/24
TM 65E/24
TM 70/A/24
TPM 80E/24

Pres. switch

bar
1,42,8
1,42,8
2,03,5
4,06,0

DN1 DN2
G1
G1
G1
G1
G1
G1
G 3/4 G1

mm
L
400
400
360
430
485
B

H
560
560
575
575

kg
13,3
13,3
17,7
22

H
508
508
255 530
526
526

kg
25
25
29
32,2

TURBOMAT 1/1
3~ 230/400V
T 61E/20
T 65E/20
T 70/A/20
TP 80E/20

1~ 230 V
TM 61E/20
TM 65E/20
TM 70/A/20
TPM 80E/20

Pres. switch

bar
1,42,8
1,42,8
2,03,5
4,06,0

DN1 DN2
G1
G1
G1
G1
G1
G1
G 3/4 G1

mm
L

* Maximum pump flow at minimum set pressure of pressure switch.


516

CENTRIMAT

Systems with centrifugal pumps


series NM, NMD

Coverage chart
0 U.S. g.p.m.
40

Imp.g.p.m.

10

15

0 U.S. g.p.m.

20

10

15

70

NM

H
m

120

Imp.g.p.m.

10
5

15

20

10

15

200

NMD

ft
100

30

ft

50
20/140AE

40

80

2/A/A

150

20/140AE
20/140BE

2/B/A

20

100

30
60

20/110A/A

2/S/A

20

1/AE

20/110B/A

40
10

20/110Z/A

50

10
m3/h

1
20

Q l/min

40

6
100

60

80

m3/h

20

Q l/min

40

4
60

6
100

5
80

72.941.1.C

72.941.2.C

Characteristic, dimensions and weights


CENTRIMAT

CENTRIMAT 1/1
DN2

CENTRIMAT

DN1

DN2
DN1
CENTRIMAT 1/1

3.93.045
3.93.046

CENTRIMAT
3~ 230/400V
NM 1/AE/24
NM 2/B/A/24
NM 2/S/A/24
NM 2/A/A/24
NMD 20/110B/A/24
NMD 20/110Z/A/24
NMD 20/110A/A/24
NMD 20/140BE/24

HP
0,5
0,75
0,75
1
0,6
0,75
1
1,5
2
2

Q
max*
l/min
73
80
80
100
60
70
70
80
80
90

HP
0,5
0,75
0,75
1
0,6
0,75
1
1,5
2
2

Q
max*
l/min
73
80
80
100
60
70
70
80
80
90

1~ 230V
NMM 1/AE/24
NMM 2/B/A/24
NMM 2/S/A/24
NMM 2/A/A/24
NMDM 20/110B/A/24
NMDM 20/110Z/A/24
NMDM 20/110A/A/24
NMDM 20/140BE/24
NMDM 20/140AE/24

NMD 20/140AE/24

kW
0,37
0,55
0,55
0,75
0,45
0,55
0,75
1,1
1,5
1,5

Pres. switch

bar
1,01,8
1,42,4
1,42,8
2,03,0
1,42,8
1,83,2
2,23,6
3,55,0
3,45,4
4,46,4

DN1 DN2
G1
G1
G1
G1
G1
G1
G1
G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1

mm
L
400
440
440
440
430
360
430
430
510
510
510
B

H
620
650
650
650
635
635
635
670
670
670

kg
17,7
21,4
21,5
22,7
21,2
22,3
23,4
30,7
33
32

H
567
600
600
600
582
255 530
582
582
619
619
619

kg
18,5
22,2
22,3
23,5
22
23,1
24,2
31,5
33
32

CENTRIMAT 1/1
3~ 230/400V
NM 1/AE/20
NM 2/B/A/20
NM 2/S/A/20
NM 2/A/A/20
NMD 20/110B/A/20
NMD 20/110Z/A/20
NMD 20/110A/A/20
NMD 20/140BE/20
NMD 20/140AE/20

1~ 230V
NMM 1/AE/20
NMM 2/B/A/20
NMM 2/S/A/20
NMM 2/A/A/20
NMDM 20/110B/A/20
NMDM 20/110Z/A/20
NMDM 20/110A/A/20
NMDM 20/140BE/20
NMDM 20/140AE/20

kW
0,37
0,55
0,55
0,75
0,45
0,55
0,75
1,1
1,5
1,5

Pres. switch

bar
1,01,8
1,42,4
1,42,8
2,03,0
1,42,8
1,83,2
2,23,6
3,55,0
3,45,4
4,46,4

DN1 DN2
G1
G1
G1
G1
G1
G1
G1
G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1

* Maximum pump flow at minimum set pressure of pressure switch.


517

mm
L

51

CENTRIMAT

Systems with Multi-Stage


series MGP

Coverage chart
0 U.S. g.p.m. 5
0

10

Imp. g.p.m. 5

15

20

10

15

20

0
60

60

MGP

MGP 205

50

30

MGP 203

20
10

30
20

MGP

MGP 405

150

MGP 204

Imp. g.p.m.

50

m
40

10

U.S. g.p.m.

150

MGP 404

40

ft
100

ft

MGP 403

30

100

20

20

50

50
10

10

m /h 1
0
0 Q l/min
20

40

60

80

0
0

m3/h

Q l/min

50

6
100

Characteristic, dimensions and weights


CENTRIMAT

CENTRIMAT 1/1

DN2
CENTRIMAT

DN1

DN2
DN1
CENTRIMAT 1/1

4.93.281

4.93.316

4.93.316

CENTRIMAT
3~ 230/400V
MGP 203/24
MGP 204/24
MGP 205/24
MGP 403/24
MGP 404/24
MGP 405/24

HP
0,6
0,75
1
0,75
1
1,5

Q
max*
l/min
65
70
70
110
110
110

HP
0,6
0,75
1
0,75
1
1,5

Q
max*
l/min
65
70
70
110
110
110

1~ 230V
MGPM
MGPM
MGPM
MGPM
MGPM
MGPM

203/24
204/24
205/24
403/24
404/24
405/24

kW
0,45
0,55
0,75
0,55
0,75
1,1

DN1
G1
G1
G1
G1
G1
G1

DN2
G1
G1
G1
G1
G1
G1

mm
L
427
456
456
360
456
456
456

H
583
583
583
583
583
583

kg
14
15
19
15
16
20

DN1
G1
G1
G1
G1
G1
G1

DN2
G1
G1
G1
G1
G1
G1

mm
L
530
530
530
255
530
530
530

H
516
516
516
516
532
532

kg
15
16
19
16
17
21

Pres. switch

bar
1,22,4
2,03,5
3,04,5
1,22,4
2,03,5
3,04,5

CENTRIMAT 1/1
3~ 230/400V
MGP 203/20
MGP 204/20
MGP 205/20
MGP 403/20
MGP 404/20
MGP 405/20

1~ 230V
MGPM
MGPM
MGPM
MGPM
MGPM
MGPM

203/20
204/20
205/20
403/20
404/20
405/20

kW
0,45
0,55
0,75
0,55
0,75
1,1

Pres. switch

bar
1,22,4
2,03,5
3,04,5
1,22,4
2,03,5
3,04,5

* Maximum pump flow at minimum set pressure of pressure switch.


518

CENTRIMAT

Systems with Multi-Stage stainless steel


series MXP

Coverage chart
0 U.S. g.p.m. 5

0
60

10

Imp. g.p.m. 5

15

20

10

15

0
60

20

MXP

MXP 205
50

30

MXP 203

20

30

20

10

MXP

MXP 405

150

MXP 204

Imp. g.p.m.

50

H
m
40

10

U.S. g.p.m.

150

m
40

ft
100

MXP 404
ft

MXP 403

30

100

20

20

50

50
10

10

0
0
m3/h 1
Q l/min
0
20

2
40

60

5
80

0
0

m3/h

Q l/min

4
50

6
100

72.1143.2

72.1143.1

Characteristic, dimensions and weights


CENTRIMAT

CENTRIMAT 1/1

DN2
CENTRIMAT

DN1

DN2
DN1
CENTRIMAT 1/1

4.93.281

4.93.316

4.93.316

CENTRIMAT
3~ 230/400V
MXP 203/24
MXP 204/A/24
MXP 205/24
MXP 403/A/24
MXP 404/A/24
MXP 405/24

HP
0,6
0,75
1
0,75
1
1,5

Q
max*
l/min
65
70
70
110
110
110

HP
0,6
0,75
1
0,75
1
1,5

Q
max*
l/min
65
70
70
110
110
110

1~ 230V
MXPM
MXPM
MXPM
MXPM
MXPM
MXPM

203/24
204/A/24
205/24
403/A/24
404/A/24
405/24

kW
0,45
0,55
0,75
0,55
0,75
1,1

DN1
G1
G1
G1
G1
G1
G1

DN2
G1
G1
G1
G1
G1
G1

mm
L
427
456
456
360
456
456
456

H
583
583
583
583
583
583

kg
14
15
16
15
16
19

DN1
G1
G1
G1
G1
G1
G1

DN2
G1
G1
G1
G1
G1
G1

mm
L
530
530
530
255
530
530
530

H
532
532
532
532
532
532

kg
15
16
17
16
17
20

Pres. switch

bar
1,22,4
2,03,5
3,04,5
1,52,7
2,03,5
3,04,5

CENTRIMAT 1/1
3~ 230/400V
MXP 203/20
MXP 204/A/20
MXP 205/20
MXP 403/A/20
MXP 404/A/20
MXP 405/20

1~ 230V
MXPM
MXPM
MXPM
MXPM
MXPM
MXPM

203/20
204/A/20
205/20
403/A/20
404/A/20
405/20

kW
0,45
0,55
0,75
0,55
0,75
1,1

Pres. switch

bar
1,22,4
2,03,5
3,04,5
1,52,7
2,03,5
3,04,5

* Maximum pump flow at minimum set pressure of pressure switch.


519

51

CENTRIMAT

Systems with Multi-Stage stainless steel


series MXH

Coverage chart
0

U.S. g.p.m. 5

Imp. g.p.m.

10
5

15
10

15

60

MXH

MXH 205/A

50

150

MXH 204/A

0
60

Imp. g.p.m.

10

20

MXH 203E

100

30
20

10

MXH 405/A

MXH

150

MXH 404/A

40

ft

30

U.S. g.p.m.

50

m
40

20

ft

MXH 403/A

30

100

20

20

50

50
10

0
0

m 3/h
l/min

1
20

2
40

60

80

10
0
0

m3/h
l/min

4
50

6
100

72.942.1.C

72.942.2.C

Characteristic, dimensions and weights


CENTRIMAT

CENTRIMAT 1/1

DN2
CENTRIMAT

DN1

DN2
DN1
CENTRIMAT 1/1

3.93.047

3.93.048

CENTRIMAT
3~ 230/400V
MXH
MXH
MXH
MXH
MXH

203E/24
204/A/24
205/A/24
403/A/24
404/A/24

HP
0,6
0,75
1
0,75
1
1,5
1,5

Q
max*
l/min
70
62
65
120
110
115
115

HP
0,6
0,75
1
0,75
1
1,5
1,5

Q
max*
l/min
70
62
65
120
110
115
115

1~ 230V
MXHM
MXHM
MXHM
MXHM
MXHM
MXHM

203E/24
204/A/24
205/A/24
403/A/24
404/A/24
405/24

MXH 405/B/24

kW
0,45
0,55
0,75
0,55
0,75
1,1
1,1

DN1 DN2
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1

mm
L
417
443
443
360 443
443
502
443

H
590
590
590
590
590
590
590

kg
15
16,5
18
16
17,5
23,5
18,5

DN1 DN2
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1
G 11/4 G1

mm
L
530
530
530
255 530
530
530
530

H
540
540
540
540
540
540
540

kg
16
17,5
19
17
18,5
24,5
19,5

Pres. switch

bar
1,42,8
2,54,0
2,54,5
1,52,7
2,03,5
2,54,5
2,54,5

CENTRIMAT 1/1
3~ 230/400V
MXH
MXH
MXH
MXH
MXH

203E/20
204/A/20
205/A/20
403/A/20
404/A/20

MXH 405/B/20

1~ 230V
MXHM
MXHM
MXHM
MXHM
MXHM
MXHM

203E/20
204/A/20
205/A/20
403/A/20
404/A/20
405/20

kW
0,45
0,55
0,75
0,55
0,75
1,1
1,1

Pres. switch

bar
1,42,8
2,54,0
2,54,5
1,52,7
2,03,5
2,54,5
2,54,5

* Maximum pump flow at minimum set pressure of pressure switch.


520

CENTRIMAT

Systems with Multi-Stage Self-Priming pumps


series MXA

Coverage chart
0

U.S. g.p.m. 5

Imp. g.p.m.

10
5

15
10

15

60

MXA

50

m
40

150

MXA 204/A

0
60

Imp. g.p.m.

10

20

MXA 203

30
20

10

MXA
MXA 405

150

40

ft
100

30

U.S. g.p.m.

50

MXA 205

20

MXA 404/A

30

ft
100

MXA 403/A

20

20

50

50
10

0
0

m 3/h
l/min

1
20

2
40

60

80

10
0
0

m3/h
l/min

4
50

6
100

72.942.1.C

72.942.2.C

Characteristic, dimensions and weights


CENTRIMAT

CENTRIMAT 1/1

DN2
CENTRIMAT

DN1

DN2
DN1
CENTRIMAT 1/1

4.93.281

4.93.316

4.93.316

CENTRIMAT
3~ 230/400V
MXA 203/24
MXA 204/A/24
MXA 205/24
MXA 403/A/24
MXA 404/A/24
MXA 405/24

HP
0,6
0,75
1
0,75
1
1,5

Q
max*
l/min
62
66
66
108
108
105

HP
0,6
0,75
1
0,75
1
1,5

Q
max*
l/min
62
66
66
108
108
105

1~ 230V
MXAM
MXAM
MXAM
MXAM
MXAM
MXAM

203/24
204/A/24
205/24
403/A/24
404/A/24
405/24

kW
0,45
0,55
0,75
0,55
0,75
1,1

DN1 DN2
G1
G1
G1
G1
G 11/4 G1
G1
G1
G1
G1
G 11/4 G1

mm
L
427
456
529
360
456
456
529

H
583
583
626
583
583
626

kg
13
16
22
16
17
23

DN1 DN2
G1
G1
G1
G1
G 11/4 G1
G1
G1
G1
G1
G 11/4 G1

mm
L
530
530
530
255
530
530
530

H
532
532
575
532
532
575

kg
14
17
23
17
18
24

Pres. switch

bar
1,22,4
2,03,5
2,54,5
1,52,7
2,03,5
2,54,5

CENTRIMAT 1/1
3~ 230/400V
MXA 203/20
MXA 204/A/20
MXA 205/20
MXA 403/A/20
MXA 404/A/20
MXA 405/20

1~ 230V
MXAM
MXAM
MXAM
MXAM
MXAM
MXAM

203/20
204/A/20
205/20
403/A/20
404/A/20
405/20

kW
0,45
0,55
0,75
0,55
0,75
1,1

Pres. switch

bar
1,22,4
2,03,5
2,54,5
1,52,7
2,03,5
2,54,5

* Maximum pump flow at minimum set pressure of pressure switch.


521

51

GETTOMAT

Systems with Self-Priming jet pumps


series NG, NGL

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

10
5

15

20

10

15

U.S. g.p.m. 10

Imp. g.p.m.

20
10

30

40

20

30

70
50

NGL 2,3,4
NG 3,4

H
m
40

NG 5/16E
NG 6/22E
NG 7/22/A

60

150

7/22E

50

200

ft

150

NG 3/A

6/22E

H
100

30

5/16E

NG 4/A

3~

6/22E

ft

1~

100

30

NGL 3/A
20

NGL 4/A

NGL 2
0
0

m3 /h

Q l/min

50

2
20

40

20

60

80

0
0

m3/h

Q l/min

4
40

6
80

10
160

120

72.943.2.C

72.943.1.C

Characteristic, dimensions and weights


GETTOMAT 1/1

GETTOMAT

DN2
GETTOMAT

DN1

DN2
DN1
GETTOMAT 1/1

3.93.051

3.93.052

GETTOMAT
3~ 230/400V
NGL 2/24
NGL 3/A/24
NGL 4/A/24
NG 3/A/24
NG 4/A/24
NG 5/16E/24

1~ 230V
NGLM 2/24
NGLM 3/A/24
NGLM 4/A/24
NGM 3/A/24
NGM 4/A/24
NGM 5/16E/24
NGM 6/22E/24

NG 6/22E/24
NG 7/22/A/24

Q
max *
kW HP l/min
0,45 0,6
35
0,55 0,75
45
0,75 1
72
0,55 0,75
50
0,75 1
65
1,1 1,5
65
1,5
2
140
1,5
2
140
2,2
3
150

Pres. switch

bar
2,03,5
2,54,0
2,03,5
2,54,0
2,03,5
3,55,0
2,54,0
2,54,5
3,55,0

DN1
G1
G1
G1
G1
G1
G 11/2
G 11/2
G 11/2
G 11/2

DN2
G1
G1
G1
G1
G1
G1
G1
G1
G1

DN1
G1
G1
G1
G1
G1
G 11/2
G 11/2
G 11/2
G 11/2

DN2
G1
G1
G1
G1
G1
G1
G1
G1
G1

mm
L
H
kg
427 583 14,5
456 583 16,5
456 583 17,5
610 25,1
480
360
610 28,9
650 35,5
650 37,5
570
650 37,5
650 39,5
B

GETTOMAT 1/1
3~ 230/400V
NGL 2/20
NGL 3/A/20
NGL 4/A/20
NG 3/A/20
NG 4/A/20
NG 5/16E/20
NG 6/22E/20
NG 7/22/A/20

1~ 230V
NGLM 2/20
NGLM 3/A/20
NGLM 4/A/20
NGM 3/A/20
NGM 4/A/20
NGM 5/16E/20
NGM 6/22E/20
-

Q
max *
kW HP l/min
0,45 0,6
35
0,55 0,75
45
0,75 1
72
0,55 0,75
50
0,75 1
65
1,1 1,5
65
1,5
2
140
1,5
2
140
2,2
3
150

Pres. switch

bar
2,03,5
2,54,0
2,03,5
2,54,0
2,03,5
3,55,0
2,54,0
2,54,5
3,55,0

mm
L

H
516
516
530 516
548
255
548
577
580 577
577
600 577

* Maximum pump flow at minimum set pressure of pressure switch.


522

kg
15,5
17,5
18,5
26
29,7
36,2
38,5
38,5
40

GETTOMAT

Systems with Self-Priming jet pumps


series NGX

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

10
5

15

20

10

15

U.S. g.p.m. 10

Imp. g.p.m.

20
10

30

40

20

30

70
50

NGX

NGX 5/16
NGX 6/22

60

150

m
40

NGX 3/A

200

50

NGX 5/16

ft

150

H
100

30

ft

NGX 4/A

30

NGX 2

100

NGX 6/22

20
50
0
0

m3 /h

Q l/min

2
20

40

20

60

80

m3/h

0
0

Q l/min

4
40

6
80

NGX 5/2210

120

160

72.1144.1

72.1144

Characteristic, dimensions and weights


GETTOMAT 1/1
GETTOMAT
DN2
DN1

GETTOMAT

DN2
DN1
GETTOMAT 1/1

4.93.281

4.93.316

4.93.316

GETTOMAT
3~ 230/400V
NGX
NGX
NGX
NGX
NGX

2/24
3/A/24
4/A/24
5/16/24
6/22/24

HP
0,6
0,75
1
1,5
2

Q
max*
l/min
35
45
72
62
150

HP
0,6
0,75
1
1,5
2

Q
max*
l/min
35
45
72
62
150

1~ 230V
NGXM
NGXM
NGXM
NGXM
NGXM

2/24
3/A/24
4/A/24
5/16/24
6/22/24

kW
0,45
0,55
0,75
1,1
1,5

DN1
G1
G1
G1
G 11/4
G 11/4

DN2
G1
G1
G1
G1
G1

mm
L
427
456
360 456
528
528

H
583
583
583
626
626

kg
14,5
16,5
17,5
23,5
25,5

DN1
G1
G1
G1
G 11/4
G 11/4

DN2
G1
G1
G1
G1
G1

mm
L
530
530
255 530
530
530

H
532
532
532
575
575

kg
15,5
17,5
18,5
24,5
26,5

Pres. switch

bar
2,03,5
2,54,0
2,03,5
3,55,0
2,54,0

GETTOMAT 1/1
3~ 230/400V
NGX
NGX
NGX
NGX
NGX

2/20
3/A/20
4/A/20
5/16/20
6/22/20

1~ 230V
NGXM
NGXM
NGXM
NGXM
NGXM

2/20
3/A/20
4/A/20
5/16/20
6/22/20

kW
0,45
0,55
0,75
1,1
1,5

Pres. switch

bar
2,03,5
2,54,0
2,03,5
3,55,0
2,54,0

* Maximum pump flow at minimum set pressure of pressure switch.


523

51

BS.. .EM

Pressure boosting sets with 1 to 3 pumps


with EASYMAT frequency converter

Possibility to display:
- Pressure of the system
- Working frequency
- Absorbed current
- Alarms

Operation
BS1V1F

Pressure boosting sets with 1 variable speed pump (with


EASYMAT) and 1 fixed speed pump
According to the water consumption, one or more pumps
start, one at variable speed and one at fixed speed, to grant
the water quantity required at the set pressure.

BS1-3V

Pressure boosting sets with 1 to 3 variable speed pumps


(with EASYMAT).
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.

Applications
For drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure)

Motors
2-pole induction motors, 50Hz, n 2900 rpm, suitable for operation with
frequency converter
- Single-phase 230V +/-10%
- Three-phase 230V +/-10%
Class F insulation
IP 54 protection
Execution according IEC 60034
Other voltages on demand

Operation
CONSTANT PRESSURE MODE:
the system keeps the pressure constant when the quantity of
water requested by the user changes.
FIXED SPEED MODE:
the system works at a fixed speed that user can choose according to his need.

Execution
Pressure vessels (on demand)

Constant pressure boosting sets with EASYMAT frequency converter


made of 1 to 3 pumps, ball valve and non return valve on suction side,
ball valve and pressure gauge on delivery side.
Suction and delivery manifolds in stainless steel AISI 304 for 2 and 3
pump units.
Suitable for installation of a 8-lt cylindrical pressure vessel on delivery
side.

Cylindrical with capactiy 8 liters, membrane type, air precharged

EASYMAT device:
Frequency converter installed directly on the pump delivery pipe and
water cooled (patented).
Only three parameters to set at starting:
- Maximum motor current
- Working frequency
- Working pressure

524

BS. MXP. EM

Pressure boosting sets with 1 to 3 horizontal multi-stage


pumps with EASYMAT frequency converter

Coverage chart
0

Imp. g.p.m.

20

30

40

50

0
60

60

60

1-3MXP 2

50
H
m
40

Imp. g.p.m.

60

30

1-3MXP 4

50
H
m
40

150
ft

150
ft
5

30

100

30

100

4
3

0
m3/h 3
Q l/min 60
0

50

50

10

20

20

12

6
120

10

180

15
240

0
0

m3/h

Q l/min

6
100

12
200

24
400

18
300

Characteristic and dimensions


B

h2

DN2

made in italy

h1

DN1

4.93.334.1

m1

B2

L2
L1

Mains:
1~1 ~
230V
230 V
Aliment.:
Motor:
230V
230 V
Motore:3~3 ~

BSM1V 1MXP 202-EMT


BSM1V 1MXP 203-EMT
BSM1V 1MXP 204-EMT
BSM1V 1MGP 205-EMT
BSM1V 1MGP 402-EMT
BSM1V 1MXP 403-EMT
BSM1V 1MXP 404-EMT
BSM1V 1MXP 405-EMT

mains
Aliment. motor
motore
A
A
2,1
3,2
4
5
3,2
4,3
5
6,4

1,7
2,4
2,8
3,5
2,4
3
3,5
4,5

Mains:
1~
230V
230 V
Aliment.:
1~
Motor:
230V
230 V
Motore:1~
1~

BSM1V 1MXPM 202-EMM


BSM1V 1MXPM 203-EMM
BSM1V 1MXPM 204-EMM
BSM1V 1MXPM 205-EMM
BSM1V 1MXPM 402-EMM
BSM1V 1MXPM 403-EMM
BSM1V 1MXPM 404-EMM
BSM1V 1MXPM 405-EMM

mm

P2
A

kW

HP

2,3
3
3,3
5,4
3
3,5
5,4
7

0,33
0,45
0,55
0,75
0,45
0,55
0,75
1,1

0,45
0,6
0,75
1
0,6
0,75
1
1,5

525

DN1 DN2

G1

G1

h1

h2

L1

L2

516
516
G 1 680 127 495
269
545
545
516
545
G 1 680 127 495
269
545
575

m1

B2

95 165 146

95 165 146

51

BS. MXP. EM

Pressure boosting sets with 1 to 3 horizontal multi-stage


pumps with EASYMAT frequency converter

Characteristic and dimensions

h2

DN2

made in italy

made in italy

h1

DN1

m1
B

L2

B2

L1

Mains:
1~
230 V
Aliment.:
1 ~230V
Motor:
230 V
Motore:3~
3 ~230V

Mains:
1~
230 V
1 ~230V
Aliment.:
Motor:
1~
230 V
1 ~230V
Motore:
mains
Aliment. motor
motore
A
A

BSM2V 2MXP 202-EMT


BSM2V 2MXP 203-EMT
BSM2V 2MXP 204-EMT
BSM2V 2MXP 205-EMT
BSM2V 2MXP 402-EMT
BSM2V 2MXP 403-EMT
BSM2V 2MXP 404-EMT
BSM2V 2MXP 405-EMT

2 x 2,1 2 x 1,7
2 x 3,2 2 x 2,4
2x4

2 x 2,8

2x5

2 x 3,5

2 x 3,2 2 x 2,4
2 x 4,3

2x3

2x5

2 x 3,5

2 x 6,4 2 x 4,5

BSM2V 2MXPM 202-EMM


BSM2V 2MXPM 203-EMM
BSM2V 2MXPM 204-EMM
BSM2V 2MXPM 205-EMM
BSM2V 2MXPM 402-EMM
BSM2V 2MXPM 403-EMM
BSM2V 2MXPM 404-EMM
BSM2V 2MXPM 405-EMM

mm

P2
A

kW

HP

DN1 DN2

h1

h2

L1

L2

m1

B2

573
573
2 x 0,45 2 x 0,6
G 2 G 1 1/2 841 150 510
326 240 600 625
602
2 x 0,55 2 x 0,75
602
2 x 0,75 2 x 1
573
2 x 0,45 2 x 0,6
602
2 x 0,55 2 x 0,75
G 2 G 1 1/2 841 150 510
326 240 600 625
602
2 x 0,75 2 x 1
632
2 x 1,1 2 x 1,5

2 x 2,3 2 x 0,33 2 x 0,45


2x3
2 x 3,3
2 x 5,4
2x3
2 x 3,5
2 x 5,4
2x7

h2

DN2

made in italy

made in italy

made in italy

h1

DN1

m1
L2

L1

B2

Mains:
1~1 ~230V
230 V
Aliment.:
Motor:
230 V
Motore:3~3 ~230V

BSM3V 3MXP 202-EMT


BSM3V 3MXP 203-EMT
BSM3V 3MXP 204-EMT
BSM3V 3MXP 205-EMT
BSM3V 3MXP 402-EMT
BSM3V 3MXP 403-EMT
BSM3V 3MXP 404-EMT
BSM3V 3MXP 405-EMT

mains
Aliment. motor
motore
A
A

Mains:
1~1 ~230V
230 V
Aliment.:
Motor:
230 V
Motore:1~1 ~230V
A

3 x 2,1 3 x 1,7 BSM3V 3MXPM 202-EMM


3 x 3,2 3 x 2,4 BSM3V 3MXPM 203-EMM
3x4

3 x 2,8 BSM3V 3MXPM 204-EMM

3x5

3 x 3,5 BSM3V 3MXPM 205-EMM

3 x 3,2 3 x 2,4 BSM3V 3MXPM 402-EMM


3 x 4,3
3x5

3x3

BSM3V 3MXPM 403-EMM

3 x 3,5 BSM3V 3MXPM 404-EMM

3 x 6,4 3 x 4,5 BSM3V 3MXPM 405-EMM

mm

P2
kW

HP

DN1 DN2

h1

h2

L1

L2

m1

B2

573
3 x 2,3 3 x 0,33 3 x 0,45
573
3 x 3 3 x 0,45 3 x 0,6
G 2 G 1 1/2 841 150 510
326 240 600 625
602
3 x 3,3 3 x 0,55 3 x 0,75
602
3 x 5,4 3 x 0,75 3 x 1
573
3 x 3 3 x 0,45 3 x 0,6
602
3 x 3,5 3 x 0,55 3 x 0,75
G 2 G 1 1/2 841 150 510
326 240 600 625
602
3 x 5,4 3 x 0,75 3 x 1
632
3 x 7 3 x 1,1 3 x 1,5

526

BS. MGP. EM

Pressure boosting sets with 1 to 3 horizontal multi-stage


pumps with EASYMAT frequency converter

Coverage chart
0

Imp. g.p.m.

20

30

40

50

0
60

60

60

1-3MGP 2

50
H
m
40

Imp. g.p.m.

60

30

1-3MGP 4

50
H
m
40

150
ft

150
ft
5

30

100

30

100

4
20

20
3

0
m3/h 3
Q l/min 60
0

50

10

120

10

12

50

180

15
240

0
0

6
100

m3/h

Q l/min

Characteristic and dimensions

12
200

24
400

18
300

h2

DN2

made in italy

h1

DN1

4.93.334.1

m1

B2

L2
L1

Mains:
1~
230 V
Aliment.:
1 ~230V
Motor:
230 V
Motore:3~
3 ~230V

BSM1V 1MGP 202-EMT


BSM1V 1MGP 203-EMT
BSM1V 1MGP 204-EMT
BSM1V 1MGP 205-EMT
BSM1V 1MGP 402-EMT
BSM1V 1MGP 403-EMT
BSM1V 1MGP 404-EMT
BSM1V 1MGP 405-EMT

mains
Aliment. motor
motore
A
A
2,1
3,2
4
5
3,2
4,3
5
6,4

1,7
2,4
2,8
3,5
2,4
3
3,5
4,5

Mains:
230 V
Aliment.:1~
1 ~230V
Motor:
230 V
Motore: 1~
1 ~230V

BSM1V 1MGPM 202-EMM


BSM1V 1MGPM 203-EMM
BSM1V 1MGPM 204-EMM
BSM1V 1MGPM 205-EMM
BSM1V 1MGPM 402-EMM
BSM1V 1MGPM 403-EMM
BSM1V 1MGPM 404-EMM
BSM1V 1MGPM 405-EMM

mm

P2
A

kW

HP

2,3
3
3,3
5,4
3
3,5
5,4
7

0,33
0,45
0,55
0,75
0,45
0,55
0,75
1,1

0,45
0,6
0,75
1
0,6
0,75
1
1,5

527

DN1 DN2

G1

G1

h1

h2

L1

L2

516
516
G 1 685 116 504
269
516
545
516
516
G 1 685 116 504
269
545
575

m1

B2

95 165 146

95 165 146

51

BS. MGP. EM

Pressure boosting sets with 1 to 3 horizontal multi-stage


pumps with EASYMAT frequency converter

Characteristic and dimensions

h2

DN2

made in italy

made in italy

h1

DN1

m1
B

L2

B2

L1

Mains:
1~
230 V
Aliment.:
1 ~230V
Motor:
230 V
Motore:3~
3 ~230V

Mains:
1~1 ~230V
230 V
Aliment.:
Motor:
1~1 ~230V
230 V
Motore:
mains
Aliment. motor
motore
A
A

BSM2V 2MGP 202-EMT


BSM2V 2MGP 203-EMT
BSM2V 2MGP 204-EMT
BSM2V 2MGP 205-EMT
BSM2V 2MGP 402-EMT
BSM2V 2MGP 403-EMT
BSM2V 2MGP 404-EMT
BSM2V 2MGP 405-EMT

2 x 2,1 2 x 1,7 BSM2V 2MGPM 202-EMM

kW

HP

DN1 DN2

h1

h2

L1

L2

m1

B2

573
573
2 x 0,45 2 x 0,6
G 2 G 1 1/2 825 150 494
326 240 600 625
573
2 x 0,55 2 x 0,75
602
2 x 0,75 2 x 1
573
2 x 0,45 2 x 0,6
573
2 x 0,55 2 x 0,75
G 2 G 1 1/2 825 150 494
326 240 600 625
602
2 x 0,75 2 x 1
632
2 x 1,1 2 x 1,5

2 x 2,3 2 x 0,33 2 x 0,45


2x3

2 x 3,2 2 x 2,4 BSM2V 2MGPM 203-EMM


2x4

2 x 2,8 BSM2V 2MGPM 204-EMM

2 x 3,3

2x5

2 x 3,5 BSM2V 2MGPM 205-EMM

2 x 5,4

2x3
BSM2V 2MGPM 403-EMM 2 x 3,5
2 x 5 2 x 3,5 BSM2V 2MGPM 404-EMM 2 x 5,4
2 x 6,4 2 x 4,5 BSM2V 2MGPM 405-EMM 2 x 7
2 x 3,2 2 x 2,4 BSM2V 2MGPM 402-EMM
2 x 4,3

mm

P2

2x3

h2

DN2

made in italy

made in italy

made in italy

h1

DN1

m1
B

L2

B2

Mains:
230 V
Aliment.:1~
1 ~230V
Motor:
230 V
Motore:3~
3 ~230V

BSM3V 3MGP 202-EMT


BSM3V 3MGP 203-EMT
BSM3V 3MGP 204-EMT
BSM3V 3MGP 205-EMT
BSM3V 3MGP 402-EMT
BSM3V 3MGP 403-EMT
BSM3V 3MGP 404-EMT
BSM3V 3MGP 405-EMT

mains motor
Aliment.
motore
A
A

Mains:
1~
230 V
1 ~230V
Aliment.:
Motor:
230 V
1 ~230V
Motore:1~

3 x 3,2 3 x 2,4 BSM3V 3MGPM 203-EMM


3x4

3 x 2,8 BSM3V 3MGPM 204-EMM

3x5

3 x 3,5 BSM3V 3MGPM 205-EMM

3 x 3,2 3 x 2,4 BSM3V 3MGPM 402-EMM


3x5

3x3

BSM3V 3MGPM 403-EMM

3 x 3,5 BSM3V 3MGPM 404-EMM

3 x 6,4 3 x 4,5 BSM3V 3MGPM 405-EMM

mm

P2
A

3 x 2,1 3 x 1,7 BSM3V 3MGPM 202-EMM

3 x 4,3

L1

kW

HP

DN1 DN2

h1

h2

L1

L2

m1

B2

573
3 x 2,3 3 x 0,33 3 x 0,45
573
3 x 3 3 x 0,45 3 x 0,6
G 2 G 1 1/2 825 150 494
326 240 600 625
573
3 x 3,3 3 x 0,55 3 x 0,75
602
3 x 5,4 3 x 0,75 3 x 1
573
3 x 3 3 x 0,45 3 x 0,6
573
3 x 3,5 3 x 0,55 3 x 0,75
G 2 G 1 1/2 825 150 494
326 240 600 625
602
3 x 5,4 3 x 0,75 3 x 1
632
3 x 7 3 x 1,1 3 x 1,5

528

BS. MXH. EM

Pressure boosting sets with 1 to 3 horizontal multi-stage


pumps with EASYMAT frequency converter

Coverage chart
0

70

Imp. g.p.m. 15

30

45

70

1-3MXH 2

60
50
H
m
40

200

60

150

50
H
m
40

ft

30

60

30

Imp. g.p.m.

1-3MXH 4

150

ft

30

100

4
3

20

200

100

20

50

50
10

10
0 Q m 3/h 3
l/min
0
60

0
60
H
m
50

120

Imp g.p.m.

0
15
240

12

180

50

100

0
0

3
Q m /h
l/min

12

24

18
300

150

150

1-3MXH 8
150
ft

40

5
4

30

100

Characteristic and dimensions

20

50
10
B
10

20
300

200

0 Imp g.p.m.
60
H
50
m

30
500

400

100

600

200

40
700

DN2

280

1-3MXH 16
150

40

ft

30

100

h2

3
Q m /h
l/min

made in italy

0
0
0

DN1

3
2

h1

20
50

10

4.93.334.1

m1
0
0 Q m 3/h
0
l/min

20

30
400

230 V
Aliment.:
1 ~230V
Mains: 1~
230 V
Motore:
3 ~230V
Motor: 3~

40
600

50
800

mains
motor
aliment. motore

A
BSM1V 1MXH 203E-EMT
3,2
BSM1V 1MXH 204/A-EMT
4
BSM1V 1MXH 205/A-EMT
5
BSM1V 1MXH 206/B-EMT
6,3
BSM1V 1MXH 403/A-EMT
4
BSM1V 1MXH 404/A-EMT
5
BSM1V 1MXH 405/B-EMT
6,7
BSM1V 1MXH 406-EMT
8
BSM1V 1MXH 803-EMT
7,1
BSM1V 1MXH 804-EMT
8,6
BSM1V 1MXH 805/A-EMT 10,7
BSM1V 1MXH 1602-EMT
9,1
BSM1V 1MXH 1603/A-EMT 10,7

60
1000

70
1200

80

L1

~230 V
Aliment.:
Mains:
1~1230V
Motore:1~1230V
~230 V
Motor:

A
2,4
2,8
3,5
4,7
2,8
3,5
4,7
6,2
5
6,2
7,5
6,2
7,5

B2

L2

mm

P2

BSM1V 1MXHM 203E-EMM


BSM1V 1MXHM 204/A-EMM
BSM1V 1MXHM 205/A-EMM
BSM1V 1MXHM 206-EMM
BSM1V 1MXHM 403/A-EMM
BSM1V 1MXHM 404/A-EMM
BSM1V 1MXHM 405-EMM

A
3
4,2
5,4
7,4
4,2
5,4
7,4

BSM1V 1MXHM 803-EMM

7,4

529

kW
0,45
0,55
0,75
1,1
0,55
0,75
1,1
1,5
1,1
1,5
1,8
1,5
1,8

HP
0,6
0,75
1
1,5
0,75
1
1,5
2
1,5
2
2,5
2
2,5

DN1

DN2

h1

h2

G 1 1/4

G1

708 127 516

G 1 1/4

G1

708 127 516

G 1 1/2

G1

708 127 516

G2

G 1 1/2 750 117 560

L1
511
561
585
609
537
561
585
680
657
687
717
752
752

L2

m1

274
298
88
322
346
274
298
88
322
346
323
353 88
383
404
101
404

B2

165 146

165 146

165 146
165 146

51

BS. MXH. EM

Pressure boosting sets with 1 to 3 horizontal multi-stage


pumps with EASYMAT frequency converter

Characteristic and dimensions

h2

DN2

made in italy

made in italy

h1

DN1

m1
B
B2

230 V
Aliment.:
1~
Mains: 1~
230V
230 V
Motore:
3~
Motor: 3~
230V

mains motore
motor
aliment.
A
A
BSM2V 2MXH 203E-EMT
2 x 3,2
2 x 2,4
2x4
2 x 2,8
BSM2V 2MXH 204/A-EMT
2x5
2 x 3,5
BSM2V 2MXH 205/A-EMT
BSM2V 2MXH 206/B-EMT 2 x 6,3 2 x 4,7
2x4
2 x 2,8
BSM2V 2MXH 403/A-EMT
2x5
2 x 3,5
BSM2V 2MXH 404/A-EMT
BSM2V 2MXH 405/B-EMT 2 x 6,7 2 x 4,7
2x8
2 x 6,2
BSM2V 2MXH 406-EMT
2 x 7,1
2x5
BSM2V 2MXH 803-EMT
2 x 8,6
2 x 6,2
BSM2V 2MXH 804-EMT
BSM2V 2MXH 805/A-EMT 2 x 10,7 2 x 7,5
2 x 9,1
2 x 6,2
BSM2V 2MXH 1602-EMT
BSM2V 2MXH 1603/A-EMT 2 x 10,7 2 x 7,5

L2
L1

Aliment.:
1 ~ 230 V
Mains:
1~ 230V
1 ~ 230 V
Motore:
Motor:
1~ 230V
BSM2V 2MXHM 203E-EMM
BSM2V 2MXHM 204/A-EMM
BSM2V 2MXHM 205/A-EMM
BSM2V 2MXHM 206-EMM
BSM2V 2MXHM 403/A-EMM
BSM2V 2MXHM 404/A-EMM
BSM2V 2MXHM 405-EMM
BSM2V 2MXHM 803-EMM

mm

P2
A

kW

HP

2x3

2 x 0,45

2 x 0,6

2 x 4,2

2 x 0,55

2 x 0,75

2 x 5,4

2 x 0,75

2x1

2 x 7,4

2 x 1,1

2 x 1,5

2 x 4,2

2 x 0,55

2 x 0,75

2 x 5,4

2 x 0,75

2x1

2 x 7,4

2 x 1,1

2 x 1,5

2 x 7,4

2 x 1,5

2x2

2 x 1,1

2 x 1,5

2 x 1,5

2x2

2 x 1,8

2 x 2,5

2 x 1,5

2x2

2 x 1,8

2 x 2,5

DN1

DN2

h1

h2

G2

G 1 1/2 848 161 506

G2

G 1 1/2 848 161 506

G 2 1/2
G3

G2

854 161 512

G 2 1/2 882 151 551

L1

L2

563
613
637
661
589
613
637
732
727
757
787
829
829

326
350
374
398
326
350
374
398
393
423
453
481
481

m1

B2

240 600 625

240 600 625

240 600 625


240 600 625

h2

DN2

made in italy

made in italy

made in italy

h1

DN1

m1
B
B2

230 V
Aliment.:
1~
Mains: 1~
230V
230 V
Motore:
3~
Motor: 3~
230V

mains motore
motor
aliment.
A
A
BSM3V 3MXH 203E-EMT
3 x 3,2
3 x 2,4
3x4
3 x 2,8
BSM3V 3MXH 204/A-EMT
3x5
3 x 3,5
BSM3V 3MXH 205/A-EMT
BSM3V 3MXH 206/B-EMT 3 x 6,3 3 x 4,7
3x4
3 x 2,8
BSM3V 3MXH 403/A-EMT
3x5
3 x 3,5
BSM3V 3MXH 404/A-EMT
BSM3V 3MXH 405/B-EMT 3 x 6,7 3 x 4,7
3x8
3 x 6,2
BSM3V 3MXH 406-EMT
3 x 7,1
3x5
BSM3V 3MXH 803-EMT
3 x 8,6
3 x 6,2
BSM3V 3MXH 804-EMT
BSM3V 3MXH 805/A-EMT 3 x 10,7 3 x 7,5
3 x 9,1
3 x 6,2
BSM3V 3MXH 1602-EMT
BSM3V 3MXH 1603/A-EMT 3 x 10,7 3 x 7,5

L2
L1

Aliment.:
1 ~ 230 V
Mains:
1~ 230V
1 ~ 230 V
Motore:
Motor:
1~ 230V
BSM3V 3MXHM 203E-EMM
BSM3V 3MXHM 204/A-EMM
BSM3V 3MXHM 205/A-EMM
BSM3V 3MXHM 206-EMM
BSM3V 3MXHM 403/A-EMM
BSM3V 3MXHM 404/A-EMM
BSM3V 3MXHM 405-EMM
BSM3V 3MXHM 803-EMM

mm

P2
A

kW

HP

3x3

3 x 0,45

3 x 0,6

3 x 4,2

3 x 0,55

3 x 0,75

3 x 5,4

3 x 0,75

3x1

3 x ,4

3 x 1,1

3 x 1,5

3 x 4,2

3 x 0,55

3 x 0,75

3 x 5,4

3 x 0,75

3x1

3 x ,4

3 x 1,1

3 x 1,5

3 x 1,5

3x2

3 x 1,1

3 x 1,5

3 x 7,4

530

3 x 1,5

3x2

3 x 1,8

3 x 2,5

3 x 1,5

3x2

3 x 1,8

3 x 2,5

DN1

DN2

h1

h2

G2

G 1 1/2 848 161 506

G2

G 1 1/2 848 161 506

G 2 1/2
G3

G2

854 161 512

G 2 1/2 882 151 551

L1

L2

563
613
637
661
589
613
637
732
727
757
787
829
829

326
350
374
398
326
350
374
398
393
423
453
481
481

m1

B2

240 600 625

240 600 625

240 600 625


240 600 625

BS. MXSU. EM

Pressure boosting sets with 1 to 3 vertical multi-stage


pumps with EASYMAT frequency converter

Characteristic and dimensions


0 Imp g.p.m.10

20

30

40

0 Imp g.p.m.20

50

40

60

80

60

70

m
60

1-3MXSU 2

200

ft

1-3MXSU 4

50
ft

150

50
206

40

40

150

405

205

100

404

30

204

30

100
20

20

50

50
10

0 m3/h 2
Q
0 l/min 40

80

10
160

120

12
200

10

14

0 m3/h 4
Q
0 l/min

12
200

100

16

20

24 26
400

300

72.945.1C

0 Imp g.p.m.
20

40

60

80

100

72.945.2C

120

50

150

1-3MXSU 8

40

ft

Characteristic and dimensions

804

100

30
803

20
DN2

50
10

12
200

16

20
300

24
400

28

32 34

made in italy

500

4.93.335.1

72.945.3C

h2

0 m3 /h
8
Q
0
l/min 100

DN1

B2

h1

m1
L2

L1

Mains:
Aliment.:1~ 230V
1 ~ 230 V
Motore: 3~ 230V
3 ~ 230 V
Motor:
BSM1V 1MXSU 204/A-EMT
BSM1V 1MXSU 205/A-EMT
BSM1V 1MXSU 206/A-EMT
BSM1V 1MXSU 404/A-EMT
BSM1V 1MXSU 405/A-EMT
BSM1V 1MXSU 803/A-EMT
BSM1V 1MXSU 804/A-EMT

mains motore
motor
aliment.
A
A
3,9
4,7
5,4
5,4
6,4
6,4
9,4

2,7
3,3
3,8
3,8
4,5
4,5
6,6

Mains:
Aliment.:1~ 230V
1 ~ 230 V
Motore: 1~ 230V
1 ~ 230 V
Motor:
BSM1V 1MXSUM 204/A-EMM
BSM1V 1MXSUM 205/A-EMM

mm

P2
A

kW

HP

4,1
5

0,55
0,75
0,9
0,9
1,1
1,1
1,5

0,75
1
1,2
1,2
1,5
1,5
2

531

DN1

DN2

h1

1071
G 1 1/4 G 1 1/4 1095 32
1119
1071
G 1 1/4 G 1 1/4
32
1095
1095
G 1 1/4 G 1 1/4
32
1095

h2

L1

L2

m1

973
997 304 225 123
1021
973
304 225 123
997
997
304 225 123
997

B2

190 190
190 190
190 190

51

BS. MXSU. EM

Pressure boosting sets with 1 to 3 vertical multi-stage


pumps with EASYMAT frequency converter

Characteristic and dimensions

h2

DN2

made in italy

made in italy

h1

DN1
m1

L2

B2

L1

230 V
Aliment.:1~1 ~230V
Mains:
230 V
Motore: 3~3 ~230V
Motor:
BSM2V 2MXSU 204/A-EMT
BSM2V 2MXSU 205/A-EMT
BSM2V 2MXSU 206/A-EMT
BSM2V 2MXSU 404/A-EMT
BSM2V 2MXSU 405/A-EMT
BSM2V 2MXSU 803/A-EMT
BSM2V 2MXSU 804/A-EMT

Aliment.:1~1 230V
~ 230 V
Mains:
Motore:1~1 230V
~ 230 V
Motor:

mains
motor
aliment. motore
A

2 x 3,9

2 x 2,7

2 x 4,7

2 x 3,3

2 x 5,4

2 x 3,8

2 x 5,4
2 x 6,4

4.93.335.2

mm

P2
DN1

kW

HP

2 x 4,1

2 x 0,55

2 x 0,75

2x5

2 x 0,75

2x1

2 x 0,9

2 x 1,2

2 x 3,8

2 x 0,9

2 x 1,2

2 x 4,5

2 x 1,1

2 x 1,5

2 x 6,4

2 x 4,5

2 x 1,1

2 x 1,5

2 x 9,4

2 x 6,6

2 x 1,5

2x2

BSM2V 2MXSUM 204/A-EMM


BSM2V 2MXSUM 205/A-EMM

DN2

G2

G2

G2

G2

G2

G2

h1

1205
1229 66
1253
1205
66
1229
1229
66
1229

h2

L1

L2

m1

958
982 417 277 240
1006
958
417 277 240
982
982
417 277 240
982

B2

600 625
600 625
600 625

h2

DN2

made in italy

made in italy

made in italy

h1

DN1

L2

m1

B2

L1

Mains:
230 V
Aliment.:1~1 ~230V
230 V
Motore: 3~3 ~230V
Motor:
BSM3V 3MXSU 204/A-EMT
BSM3V 3MXSU 205/A-EMT
BSM3V 3MXSU 206/A-EMT
BSM3V 3MXSU 404/A-EMT
BSM3V 3MXSU 405/A-EMT
BSM3V 3MXSU 803/A-EMT
BSM3V 3MXSU 804/A-EMT

mains motore
motor
aliment.
A
A

Mains:
230 V
Aliment.:1~
1 ~230V
230 V
Motore: 1~
1 ~230V
Motor:

mm

P2
A

kW

HP

3 x 4,1

3 x 0,55

3 x 0,75

3x5

3 x 0,75

3x1

3 x 0,9

3 x 1,2

3 x 3,8

3 x 0,9

3 x 1,2

3 x 4,5

3 x 1,1

3 x 1,5

3 x 6,4

3 x 4,5

3 x 1,1

3 x 1,5

3 x 9,4

3 x 6,6

3 x 1,5

3x2

3 x 3,9

3 x 2,7

3 x 4,7

3 x 3,3

3 x 5,4

3 x 3,8

3 x 5,4
3 x 6,4

BSM3V 3MXSUM 204/A-EMM


BSM3V 3MXSUM 205/A-EMM

4.93.335.2

532

DN1

DN2

G2

G2

G2

G2

G2

G2

h1

1205
1229 66
1253
1205
66
1229
1229
66
1229

h2

L1

L2

m1

958
982 417 277 240
1006
958
417 277 240
982
982
417 277 240
982

B2

600 625
600 625
600 625

BS. MXVB. EM

Pressure boosting sets with 1 to 3 vertical multi-stage


pumps with EASYMAT frequency converter

Characteristic and dimensions


120

0 Imp. g.p.m.

20

30

40

50

120

1-3MXV-B 25-2

100

Imp. g.p.m.

30

60

90

1-3MXV-B 32-4

100
300

80

ft

80
H
m

10

200

60

8
7
6

40

5
4

10

H
m

60

300

7
6
5
4

40

100

20

200

100

20

0
0
0

100

ft

3
3
Q m /h
l/min 50

0 Imp. g.p.m.

6
100

9
150

50

0
15
250

12
200

100

0
0

m 3/h
l/min

6
100

12
100

18
300

24
400

Characteristic and dimensions

150
300

1-3MXV-B 40-8

80

ft

H
m

DN2

200

60

made in italy

DN1

100

4.93.336.1

h2

5
40

20

0
0
m3/h 6
Q
l/min
0

12
200

Mains: 1~
230 V
Aliment.:
1 ~230V
230 V
Motore:
3 ~230V
Motor: 3~
BSM1V 1MXV-B 25-204-EMT
BSM1V 1MXV-B 25-205-EMT
BSM1V 1MXV-B 25-206-EMT
BSM1V 1MXV-B 25-207-EMT
BSM1V 1MXV-B 25-208-EMT
BSM1V 1MXV-B 25-210-EMT
BSM1V 1MXV-B 32-404-EMT
BSM1V 1MXV-B 32-405-EMT
BSM1V 1MXV-B 32-406-EMT
BSM1V 1MXV-B 32-407-EMT
BSM1V 1MXV-B 32-408-EMT
BSM1V 1MXV-B 32-410-EMT
BSM1V 1MXV-B 40-804-EMT
BSM1V 1MXV-B 40-805-EMT
BSM1V 1MXV-B 40-806-EMT

18
300

24
400

30
500

36
600

A
3,3
3,3
4,7
4,7
7,5
7,5
4,7
4,7
7,5
7,5
9,15
9,15
7,5
9,15
9,15

L2

42
700

L1

Mains:
1~ 1230V
Aliment.:
~ 230 V
Motore:
~ 230 V
mains
1~ 1230V
aliment. motor
motore Motor:
5,4
5,4
7,1
7,1
10,8
10,8
7,1
7,1
10,8
10,8
13,2
13,2
10,8
13,2
13,2

m1

h1

B2

mm

P2
A

kW

HP

BSM1V 1MXV-BM 25-204-EMM


BSM1V 1MXV-BM 25-205-EMM
BSM1V 1MXV-BM 25-206-EMM
BSM1V 1MXV-BM 25-207-EMM

5,8
5,8
7,4
7,4

BSM1V 1MXV-BM 32-404-EMM


BSM1V 1MXV-BM 32-405-EMM

7,4
7,4

0,75
0,75
1,1
1,1
1,5
1,5
1,1
1,1
1,5
1,5
2,2
2,2
1,5
2,2
2,2

1
1
1,5
1,5
2
2
1,5
1,5
2
2
3
3
2
3
3

533

DN1

DN2

G1

G1

577

75 437 588 262 150 218 210

G 1 1/4 G 1 1/4 600

75 458 633 288 150 218 210

G 1 1/2 G 1 1/2 623

80 470 675 318 190 246 246

h1

h2

L1

L2

m1

B2

51

BS. MXVB. EM

Pressure boosting sets with 1 to 3 vertical multi-stage


pumps with EASYMAT frequency converter

Characteristic and
dimensions

h2

DN2

made in italy

made in italy

h1

DN1

m1

4.93.336.2

L2

B2

Mains:
1~1230V
Aliment.:
~230 V
Motore:3~3230V
~230 V
Motor:

L1

Mains:
1~1 230V
Aliment.:
~ 230 V
Motore:1~1 230V
~ 230 V
mains motore
motor Motor:
aliment.
A
A

BSM2V 2MXV-B 25-204-EMT


BSM2V 2MXV-B 25-205-EMT
BSM2V 2MXV-B 25-206-EMT
BSM2V 2MXV-B 25-207-EMT
BSM2V 2MXV-B 25-208-EMT
BSM2V 2MXV-B 25-210-EMT
BSM2V 2MXV-B 32-404-EMT
BSM2V 2MXV-B 32-405-EMT
BSM2V 2MXV-B 32-406-EMT
BSM2V 2MXV-B 32-407-EMT
BSM2V 2MXV-B 32-408-EMT
BSM2V 2MXV-B 32-410-EMT
BSM2V 2MXV-B 40-804-EMT
BSM2V 2MXV-B 40-805-EMT
BSM2V 2MXV-B 40-806-EMT

2 x 5,4
2 x 5,4
2 x 7,1
2 x 7,1
2 x 10,8
2 x 10,8
2 x 7,1
2 x 7,1
2 x 10,8
2 x 10,8
2 x 13,2
2 x 13,2
2 x 10,8
2 x 13,2
2 x 13,2

mm

P2
A

BSM2V 2MXV-BM 25-204-EMM


2 x 3,3 BSM2V 2MXV-BM 25-205-EMM
2 x 4,7 BSM2V 2MXV-BM 25-206-EMM
2 x 4,7 BSM2V 2MXV-BM 25-207-EMM
2 x 7,5
2 x 7,5
2 x 4,7 BSM2V 2MXV-BM 32-404-EMM
2 x 4,7 BSM2V 2MXV-BM 32-405-EMM
2 x 7,5
2 x 7,5
2 x 9,15
2 x 9,15
2 x 7,5
2 x 9,15
2 x 9,15
2 x 3,3

kW

HP

2 x 5,8 2 x 0,75

DN1

DN2

h1

h2

L1

L2

m1

B2

2x1

2 x 5,8 2 x 0,75

2x1

2 x 7,4

2 x 1,1

2 x 1,5

2 x 7,4

2 x 1,1

2 x 1,5

2 x 1,5

2x2

2 x 1,5

2x2

2 x 7,4

2 x 1,1

2 x 1,5

2 x 7,4

2 x 1,1

2 x 1,5

2 x 1,5

2x2

2 x 1,5

2x2

2 x 2,2

2x3

2 x 2,2

2x3

2 x 1,5

2x2

2 x 2,2

2x3

2 x 2,2

2x3

G 1 1/2 G 1 1/2 727 119 461 501 315 365 600 625

G2

G2

743 119 477 544 340 365 600 625

G 2 1/2 G 2 1/2 765 124 495 598 388 365 600 625

h2

DN2

made in italy

made in italy

made in italy

h1

DN1

m1

4.93.336.2

L2

B2

Aliment.:
~230 V
Mains:
1~1230V
Motore:3~3230V
~230 V
Motor:

mains
aliment. motor
motore
A

BSM3V 3MXV-B 25-204-EMT


BSM3V 3MXV-B 25-205-EMT
BSM3V 3MXV-B 25-206-EMT
BSM3V 3MXV-B 25-207-EMT
BSM3V 3MXV-B 25-208-EMT
BSM3V 3MXV-B 25-210-EMT
BSM3V 3MXV-B 32-404-EMT
BSM3V 3MXV-B 32-405-EMT
BSM3V 3MXV-B 32-406-EMT
BSM3V 3MXV-B 32-407-EMT
BSM3V 3MXV-B 32-408-EMT
BSM3V 3MXV-B 32-410-EMT
BSM3V 3MXV-B 40-804-EMT
BSM3V 3MXV-B 40-805-EMT
BSM3V 3MXV-B 40-806-EMT

3 x 5,4
3 x 5,4
3 x 7,1
3 x 7,1
3 x 10,8
3 x 10,8
3 x 7,1
3 x 7,1
3 x 10,8
3 x 10,8
3 x 13,2
3 x 13,2
3 x 10,8
3 x 13,2
3 x 13,2

Aliment.:
~ 230 V
Mains:
1~1 230V
Motore:1~1 230V
~ 230 V
Motor:

A
BSM3V 3MXV-BM 25-204-EMM
3 x 3,3 BSM3V 3MXV-BM 25-205-EMM
3 x 4,7 BSM3V 3MXV-BM 25-206-EMM
3 x 4,7 BSM3V 3MXV-BM 25-207-EMM
3 x 7,5
3 x 7,5
3 x 4,7 BSM3V 3MXV-BM 32-404-EMM
3 x 4,7 BSM3V 3MXV-BM 32-405-EMM
3 x 7,5
3 x 7,5
3 x 9,15
3 x 9,15
3 x 7,5
3 x 9,15
3 x 9,15
3 x 3,3

L1

mm

P2
A

kW

3 x 5,8 3 x 0,75
3 x 5,8 3 x 0,75

HP

DN2

h1

h2

L1

L2

m1

B2

3x1

3 x 7,4

3 x 1,1

3 x 1,5

3 x 7,4

3 x 1,1

3 x 1,5

3 x 1,5

3x2

3 x 1,5

3x2

3 x 7,4

3 x 1,1

3 x 1,5

3 x 7,4

3 x 1,1

3 x 1,5

3 x 1,5

3x2

3 x 1,5

3x2

3 x 2,2

3x3

3 x 2,2

3x3

3 x 1,5

3x2

3 x 2,2

3x3

3 x 2,2

3x3

534

DN1

3x1

G 1 1/2 G 1 1/2 727 119 461 501 315 365 600 625

G2

G2

743 119 477 544 340 365 600 625

G 2 1/2 G 2 1/2 765 124 495 598 388 365 600 625

BS. 4SDF. EM

Pressure boosting sets with one submersible borehole


pump with EASYMAT frequency converter

Coverage chart
120

Imp. g.p.m

9
100

19

ft
9

40

0
0

80
H
m
60

10

12
300
ft
200

7
40
4

m3/h 0,5
l/min
10

1,5

15

Imp. g.p.m

20

25
10

30
12

35
14

0
2,5

40

16

18

100

17

200

2
20

Imp. g.p.m

30

40

10

0
3,6

50

60

20

15

80
H
m
60

ft

11

m3/h
Q l/min
0

300

4SDF 36

100

20

20

100

10

200

100

4SDF 22

80
H
m
60

300

14

H
m

Imp. g.p.m
14

4SDF 16

100
80

300
H

4SDF 46

ft
200

10

8
40
20
0

100

m3/h 1
0
Q
l/min
0
20

40

100

20

30

40

3
50

60

70

80

100

30

Imp. g.p.m

40

50

4
60

10

70

80

5
90

100

20

30
300

14

Characteristic and dimensions

4SDF 54

80
H
m
60

P2
kW

HP

BSM1V 1-4SDF 16/6E-EMT

2.5

1.9

0.37

0.5

BSM1V 1-4SDF 16/9E-EMT

2.5

1.9

0.37

0.5

BSM1V 1-4SDF 16/14E-EMT

3.7

2.8

0.55

0.75

BSM1V 1-4SDF 16/19E-EMT

4.8

3.5

0.75

BSM1V 1-4SDF 22/4E-EMT

2.5

1.9

0.37

0.5

BSM1V 1-4SDF 22/7E-EMT

2.5

1.9

0.37

0.5

BSM1V 1-4SDF 22/10E-EMT

3.7

2.8

0.55

0.75

BSM1V 1-4SDF 22/14E-EMT

4.8

3.5

0.75

BSM1V 1-4SDF 36/4E-EMT

2.5

1.9

0.37

0.5

BSM1V 1-4SDF 36/6E-EMT

2.5

1.9

0.37

0.5

BSM1V 1-4SDF 36/8E-EMT

3.7

2.8

0.55

0.75

BSM1V 1-4SDF 36/11E-EMT

4.8

3.5

0.75

BSM1V 1-4SDF 36/17E-EMT

6.8

4.9

1.1

1.5

BSM1V 1-4SDF 46/5E-EMT

2.5

1.9

0.37

0.5

BSM1V 1-4SDF 46/7E-EMT

3.7

2.8

0.55

0.75

BSM1V 1-4SDF 46/10E-EMT

4.8

3.5

0.75

BSM1V 1-4SDF 46/15E-EMT

6.8

4.9

1.1

1.5

BSM1V 1-4SDF 54/5E-EMT

3.7

2.8

0.55

0.75

BSM1V 1-4SDF 54/7E-EMT

4.8

3.5

0.75

BSM1V 1-4SDF 54/10E-EMT

6.8

4.9

1.1

1.5

BSM1V 1-4SDF 54/14E-EMT

9.5

6.8

1.5

H
ft

10

200
7

40

100

20
0

m3/h
0
Q l/min
0

3
40

60

5
80

6
100

7
120

8
140
G 1 1/4

190

190

G 1 1/4

51
547

Mains:
1~1230V
Aliment.:
~ 230 V
Motor:
Motore:3~3230V
~ 230 V mains motor
aliment. motore
A
A

m3/h
Q l/min
0
20

made in italy

3.93.063.2N

96

535

BS.. .VTT2

Pressure boosting sets with 1 to 2 pumps


with VARIOMAT 2 frequency converter

Execution
Constant pressure boosting sets with VARIOMAT 2 frequency converter made of one or two pumps, ball valve and non return valve on suction side,
ball valve and pressure gauge on delivery side.
Suction and delivery manifolds in stainless steel AISI 304 for two pump units.
Suitable for installation of a 8-lt cylindrical pressure vessel on delivery side.
VARIOMAT 2 device:
Frequency converter installed directly on the pump delivery pipe and water cooled.
Only two parameters to set at starting:
- Working frequency
- Working pressure
Possibility to display:
- Pressure of the system
- Working frequency
- Absorbed current
- Alarms

Operation
According to the water consumption, one or more pumps starts, all at variable speed, to ensure the required water quantity at the set pressure.
CONSTANT PRESSURE MODE:
the system keeps the pressure constant when the quantity of water requested by the user changes.

Applications
For drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure).

Motors
2-pole induction motors, 50Hz, n 2900 rpm, suitable for operation with frequency converter
- Three-phase 400V +/-10%
Class F insulation
IP 54 protection
Execution according IEC 60034
Other voltages on demand

Pressure vessels (on demand)


Cylindrical with capactiy 8 liters, membrane type, air precharged

536

BS. MXH. VTT2

Pressure boosting sets with one horizontal multi-stage


pump with VARIOMAT 2 frequency converter

Coverage chart
70

Imp. g.p.m. 5

10

15

70

Imp. g.p.m. 10

206/A
60

1MXH 2

406

200

60

150

50
H
m
40

405/A

204/A

ft
203E

30

200

1MXH 4

205/A
50
H
m
40

20

100

150

404/A

ft
403/A

30

100

20

20

50

50
10

10
m3/h 1

0
0

l/min

2
20

40

Imp g.p.m.

20

30

60
H
m
50

80
40

805

60

50

m3/h
Q

l/min

50

100

200

1MXH 8
150

804

40

ft
803

30

Characteristic and dimensions

100
B

20
50
10
m3/h

0
0

l/min 50

100

Imp g.p.m.

10

12

150

40

60

80

60
H
m
50

14

200
100

200

1MXH 16

PRESSURE

CURRENT

SET POINT PRESSURE

bar

bar

RESTART PRESSURE

bar

h2

P529

Serial Number

150

made in italy

40

VARIOMAT 2 - 9TT
IN:

3 ~ 400V 50/60 Hz

Tmax: 60C IP65 Pmax 12 bar

P530

OUT: 3 ~ 400V 50/60 Hz max 9A

ft

P531

1603

30

100

1602
h1

20

50
4.93.545

10

B2

m1
L2
3

m /h

0
0

12

l/min 100

Mains: 3~ 400V 3 ~
Alimentazione:
Motor: 3~ 400V 3 ~
Motore:

16

200

20

24

300

28

L1

400

400 V
400 V

mm

P2
DN1

L1

L2
305

565

330

590

355

1,5

675

375

0,75

545

305

565

330

615

375

675

375

1,5

675

350

705

380

2,5

735

410

746

410

746

410

kW

HP

BS1V 1MXH 203E-VTT2/A

1,4

0,45

0,6

BS1V 1MXH 204/A-VTT2/A

1,6

0,55

0,75

BS1V 1MXH 205/A-VTT2/A

0,75

BS1V 1MXH 206/A-VTT2/A

2,7

1,1

BS1V 1MXH 403/A-VTT2/A

1,6

0,55

BS1V 1MXH 404/A-VTT2/A

0,75

BS1V 1MXH 405/A-VTT2/A

2,7

1,1

1,5

BS1V 1MXH 406-VTT2/A

3,7

1,5

BS1V 1MXH 803-VTT2/A

2,9

1,1

BS1V 1MXH 804-VTT2/A

3,7

1,5

BS1V 1MXH 805-VTT2/A

4,3

1,8

BS1V 1MXH 1602-VTT2/A

3,7

1,5

BS1V 1MXH 1603-VTT2/A

4,3

1,8

2,5

DN2

545

G 1 1/4

G 1 1/4

G 1 1/2

G2

G1

G1

G1

G 1 1/2

537

722

722

722

715

h1

127

127

127

117

h2

548

548

548

537

m1

B2

28

260

210

28

260

210

51
31

260

210

31

260

210

BS. MXH. VTT2

Pressure boosting sets with two horizontal multi-stage


pumps with VARIOMAT 2 frequency converter

Coverage chart
70

Imp. g.p.m. 10

20

30

60

70

2MXH 2

Imp. g.p.m. 20

40

200

60

2MXH 4

50
H
m
40

150

50
H
m
40

6
5

ft

30

100

200

150
5

ft

30

100

20

20
50

50
10

10
m3/h 2

0
0

l/min

4
40

80

Imp g.p.m.

120

40

60

60
H
m
50

100

2MXH 4
12

l/min

100

16

200

200

2MXH 8

Characteristic and dimensions

150
ft

30

m3/h

160
80

40

10

100

20
50
10

12

l/min 50

16

20

200

Imp g.p.m.

24

300

80

120

160

60
H
m
50

28

400
200

200
PRESSURE

CURRENT

2MXH 16

SET POINT PRESSURE

bar

bar

Serial Number

SET POINT PRESSURE

bar

RESTART PRESSURE

bar

Serial Number

made in italy

bar

made in italy

VARIOMAT 2 - 9TT

VARIOMAT 2 - 9TT

IN:

IN:

3 ~ 400V 50/60 Hz

ft

3 ~ 400V 50/60 Hz

OUT: 3 ~ 400V 50/60 Hz max 9A


P530

OUT: 3 ~ 400V 50/60 Hz max 9A


Tmax: 60C IP65 Pmax 12 bar

40

PRESSURE

CURRENT

bar

h2

150

RESTART PRESSURE

P529

Tmax: 60C IP65 Pmax 12 bar

P531

P530

P529

m3/h

P531

100

30
20

h1

3
2

50

m1

4.93.547

10

m3/h

0
0

16

l/min 100

24

32

400

Mains:
3~ 400V 3 ~
Alimentazione:
Motor:
Motore: 3~ 400V 3 ~

40
600

48

L2

B2

56

L1

800

400 V
400 V

mm

P2
DN1

DN2

L1

L2

570

330

620

355

645

380

2 x 1,5

665

405

2 x 0,75

595

330

620

355

645

380

2x2

725

405

2 x 1,5

750

430

780

460

2 x 2,5

810

490

2x2

830

495

830

495

kW

HP

BS2V 2MXH 203E-VTT2/A

2 x 1,4

2 x 0,45

2 x 0,6

BS2V 2MXH 204/A-VTT2/A

2 x 1,6

2 x 0,55

2 x 0,75

BS2V 2MXH 205/A-VTT2/A

2x2

2 x 0,75

2x1

BS2V 2MXH 206/A-VTT2/A

2 x 2,7

2 x 1,1

BS2V 2MXH 403/A-VTT2/A

2 x 1,6

2 x 0,55

BS2V 2MXH 404/A-VTT2/A

2x2

2 x 0,75

2x1

BS2V 2MXH 405/A-VTT2/A

2 x 2,7

2 x 1,1

2 x 1,5

BS2V 2MXH 406-VTT2/A

2 x 3,7

2 x 1,5

BS2V 2MXH 803-VTT2/A

2 x 2,9

2 x 1,1

BS2V 2MXH 804-VTT2/A

2 x 3,7

2 x 1,5

2x2

BS2V 2MXH 805-VTT2/A

2 x 4,3

2 x 1,8

BS2V 2MXH 1602-VTT2/A

2 x 3,7

2 x 1,5

BS2V 2MXH 1603-VTT2/A

2 x 4,3

2 x 1,8

2 x 2,5

G2

G 1 1/2

G 1 1/2

G2

G 2 1/2

G3

G2

G 2 1/2

538

858

858

864

830

h1

162

162

162

152

h2

557

557

563

679

m1

B2

234

600

625

234

600

625

234

600

625

234

600

625

BS. MXVB. VTT2

Pressure boosting sets with one vertical multi-stage


pump with VARIOMAT 2 frequency converter

Coverage chart
120

Imp. g.p.m.

10

10

15

120

1MXV-B 25-2

100

Imp. g.p.m.

10

20

100

10

ft

80
H
m

200

60

30

1MXV-B 32-4

300

300

8
80
7

H
m

60

200

40

ft

40
100

100

20

20

0
0
0

100

3
1
Q m /h
l/min
20

2
30

0 Imp. g.p.m. 10

3
50

40

20

4
60

30

5
70

40

80

0
0

m3/h
l/min

3
50

6
100

0
9
150

Characteristic and dimensions

50
300

1MXV-B 40-8

80
H
m

ft

6
200

60
5

SET POINT PRESSURE

bar

bar

RESTART PRESSURE

bar

4.93.546

P529

Serial Number

PRESSURE

CURRENT

h2

4
40

made in italy

100

VARIOMAT 2 - 9TT
IN:

3 ~ 400V 50/60 Hz
P530

OUT: 3 ~ 400V 50/60 Hz max 9A


Tmax: 60C IP65 Pmax 12 bar

P531

h1

20

4
50

6
100

10
150

12
200

m1

B2

0
0
m3/h 2
Q
l/min
0

14

L2

L1

Mains:
3~ 400V 3 ~
Alimentazione:
Motor:
Motore: 3~ 400V 3 ~

400 V
400 V

mm

P2
A

kW

HP

BS1V 1MXV-B 25-204-VTT2/A

2,3

0,75

BS1V 1MXV-B 25-205-VTT2/A

2,3

0,75

BS1V 1MXV-B 25-206-VTT2/A

2,9

1,1

1,5

BS1V 1MXV-B 25-207-VTT2/A

2,9

1,1

1,5

BS1V 1MXV-B 25-208-VTT2/A

4,3

1,5

BS1V 1MXV-B 25-210-VTT2/A

4,3

1,5

BS1V 1MXV-B 32-404-VTT2/A

2,9

1,1

1,5

BS1V 1MXV-B 32-405-VTT2/A

2,9

1,1

1,5

BS1V 1MXV-B 32-406-VTT2/A

4,3

1,5

BS1V 1MXV-B 32-407-VTT2/A

4,3

1,5

BS1V 1MXV-B 32-408-VTT2/A

5,3

2,2

BS1V 1MXV-B 32-410-VTT2/A

5,3

2,2

BS1V 1MXV-B 40-804-VTT2/A

4,3

1,5

BS1V 1MXV-B 40-805-VTT2/A

5,3

2,2

BS1V 1MXV-B 40-806-VTT2/A

5,3

2,2

DN1

DN2

G1

G1

590

G 1 1/4

G 1 1/4

G 1 1/2

G 1 1/2

539

h1

h2

L1

L2

m1

B2

75

440

716

265

150

225

260

585

75

460

761

295

150

225

260

595

80

465

825

345

150

225

260

51

BS. MXVB. VTT2

Pressure boosting sets with two vertical multi-stage


pumps with VARIOMAT 2 frequency converter

Coverage chart
120

Imp. g.p.m.

10

20

30

2MXV-B 25-2

100

30

Imp. g.p.m.

40

60

120

2MXV-B 32-4

100
300

300

10
ft

H
m

8
200

7
6

60

200

7
6
5

40

100

20

100

20

0
0
0

100

ft
8

60

40

10

80
H
m

80

3
2
Q m /h
l/min
40

4
60

0 Imp. g.p.m. 20

6
100

80

40

8
120

60

10
160

140

80

100

0
0

m3/h
l/min

6
100

10

12
200

14

16

0
18
300

Characteristic and dimensions


300

2MXV-B 40-8

80

ft

H
m

DN2

60

200

5
bar

RESTART PRESSURE

PRESSURE

CURRENT

bar

SET POINT PRESSURE

bar

made in italy

VARIOMAT 2 - 9TT

3 ~ 400V 50/60 Hz

IN:

3 ~ 400V 50/60 Hz

OUT: 3 ~ 400V 50/60 Hz max 9A


P530

OUT: 3 ~ 400V 50/60 Hz max 9A


Tmax: 60C IP65 Pmax 12 bar

bar

made in italy

VARIOMAT 2 - 9TT
IN:

RESTART PRESSURE

bar

Serial Number

SET POINT PRESSURE

bar

Serial Number

P529

h2

100

Tmax: 60C IP65 Pmax 12 bar

P530

PRESSURE

CURRENT

P529

40

P531

P531

DN1

h1

20

0
0
m /h 4
Q
l/min 100
0
3

Mains:
3~ 400V 3 ~
Alimentazione:
Motor:
Motore: 3~ 400V 3 ~

12
200

16

20
300

400 V
400 V

24
400

28

4.93.548

m1
L2

B2

L1

mm

P2
A

kW

HP

BS2V 2MXV-B 25-204-VTT2/A

2 x 2,3

2 x 0,75

BS2V 2MXV-B 25-205-VTT2/A

2 x 2,3

2 x 0,75

2x1

BS2V 2MXV-B 25-206-VTT2/A

2 x 2,9

2 x 1,1

2 x 1,5

BS2V 2MXV-B 25-207-VTT2/A

2 x 2,9

2 x 1,1

2 x 1,5

BS2V 2MXV-B 25-208-VTT2/A

2 x 4,3

2 x 1,5

2x2

BS2V 2MXV-B 25-210-VTT2/A

2 x 4,3

2 x 1,5

2x2

BS2V 2MXV-B 32-404-VTT2/A

2 x 2,9

2 x 1,1

2 x 1,5

BS2V 2MXV-B 32-405-VTT2/A

2 x 2,9

2 x 1,1

2 x 1,5

BS2V 2MXV-B 32-406-VTT2/A

2 x 4,3

2 x 1,5

2x2

BS2V 2MXV-B 32-407-VTT2/A

2 x 4,3

2 x 1,5

2x2

BS2V 2MXV-B 32-408-VTT2/A

2 x 5,3

2 x 2,2

2x3

BS2V 2MXV-B 32-410-VTT2/A

2 x 5,3

2 x 2,2

2x3

BS2V 2MXV-B 40-804-VTT2/A

2 x 4,3

2 x 1,5

2x2

BS2V 2MXV-B 40-805-VTT2/A

2 x 5,3

2 x 2,2

2x3

BS2V 2MXV-B 40-806-VTT2/A

2 x 5,3

2 x 2,2

2x3

DN1

DN2

G 1 1/2

G 1 1/2

G2

G 2 1/2

h1

h2

L1

L2

m1

B2

850

119

740

674

315

365

600

625

G2

850

119

740

644

345

365

600

625

G 2 1/2

850

124

740

709

425

365

600

625

2x1

540

BS.. .ITT

Pressure boosting sets with 1 to 3 pumps


with I-MAT frequency converter

Operation
BS2-3V

Motors
2-pole induction motors, 50Hz, n 2900 rpm, suitable for operation with
frequency converter
- Three-phase 400V +/-10%
Class F insulation
IP 54 protection
Execution according IEC 60034
Other voltages on demand

Pressure boosting sets with 2 to 3 variable speed pumps


(with EASYMAT).
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.

Operation
CONSTANT PRESSURE MODE:
the system keeps the pressure constant when the quantity of
water requested by the user changes.

Pressure vessels (on demand)


Cylindrical with capactiy 8 liters, membrane type, air precharged

FIXED SPEED MODE:


the system works at a fixed speed that user can choose according to his need.

Execution
Constant pressure boosting sets with I-MAT frequency converter made
of 2 to 3 pumps, ball valve and non return valve on suction side, ball
valve and pressure gauge on delivery side.
Suction and delivery manifolds in stainless steel AISI 304.
Suitable for installation of a 8-lt cylindrical pressure vessel on delivery
side.
I-MAT device:
Frequency converter installed on the motor with self cooling system.
Possibility to display:
- Pressure of the system
- Working frequency
- Absorbed current
- Alarms

51

Applications
For drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure)

541

BS. MXH. ITT

Pressure boosting sets with 2 to 3 horizontal


multi-stage pumps with I-MAT frequency converter

Coverage chart
0

Imp. g.p.m.

15

30

45

Imp. g.p.m.

30

60

70

70

1-3MXH 2

60

200

1-3MXH 4

60

200

50

50

150

m
40

ft

ft

30

150

m
40

6
100

100

30

20

20

50

50
10

10

m /h

0
0

0
3

l/min

60

Imp g.p.m.

12

6
120

180

50

240

100

150

12

l/min

100

200

30

50

ft

6
150

40

100

ft

30

20

200

60

150
40

280

1-3MXH 16

1-3MXH 8

50

300

70

24

18

150

0 Imp g.p.m.

200

60

m3/h

15

100

3
20

50

50

10

10

0
0
0

l/min

10

20
200

300

30
400

500

40
600

0
0

0
m3/h

700

542

m3/h

l/min

20

30
400

40
600

50
800

60
1000

70
1200

80

BS. MXH. ITT

Pressure boosting sets with 2 to 3 horizontal


multi-stage pumps with I-MAT frequency converter

Coverage chart
0 U.S. g.p.m. 75

150

225

300

200

Imp. g.p.m.

300

400

500

80

90
ft

80
70

200

60

40

1-3MXH 32

60

5
H
m

ft

70

1-3MXH 20

H
m

200

40

30

3
100

2
20

20

1
0

0
0

m 3/h
Q

l/min

20
300

30

40
600

50

60
900

10

10
0

100

30

70 75

1200

50

m 3/h
Q l/min
500

0 Imp. g.p.m.

1000

200

0
150

100

300

1500

400

2000

600

500

2500

700

70
200

60

1-3MXH 48

H
m

ft

40

3
100

30

2
20

1
10
0
0 m3/h 30
Q
0 l/min 500

60

90

120

150

180

0
210

1000

1500

2000

2500

3000

3500

51

543

BS. MXH. ITT

Pressure boosting sets with 2 to 3 horizontal


multi-stage pumps with I-MAT frequency converter

Dimensions and weights


BS.. 2MXH 2,4,8

BS.. 2MXH 16
B

L2

DN 2

L2

DN 1

h2

h1

h2

h1

3.93.159

m1

m1
L1

Motore
Motor

TYPE
BS2V 2MXH 204/A-ITT
BS2V 2MXH 205/A-ITT
BS2V 2MXH 206/B-ITT
BS2V 2MXH 403/A-ITT
BS2V 2MXH 404/A-ITT
BS2V 2MXH 405/B-ITT
BS2V 2MXH 406-ITT
BS2V 2MXH 803-ITT
BS2V 2MXH 804-ITT
BS2V 2MXH 805/A-ITT
BS2V 2MXH 1603/A-ITT
BS2V 2MXH 1604/A-ITT
BS2V 2MXH 1605/A-ITT
BS2V 2MXH 1606/A-ITT

kW
0,55 x2
0,75 x2
1,1 x2
0,55 x2
0,75 x2
1,1 x2
1,5 x2
1,1 x2
1,5 x2
1,8 x2
1,8 x2
3 x2
3,7 x2
4 x2

B2

L1

B2

Collettori
Connection

HP
0,75 x2
1 x2
1,5 x2
0,75 x2
1 x2
1,5 x2
2 x2
1,5 x2
2 x2
2,5 x2
2,5 x2
4 x2
5 x2
5,5 x2

A
1,6 x2
2 x2
2,7 x2
1,6 x2
2 x2
2,7 x2
3,6 x2
2,7 x2
3,6 x2
4,3 x2
4,3 x2
6,6 x2
9,6 x2
9,6 x2

DN 1
G2
G2
G2
G2
G2
G2
G2
G 2 1/2
G 2 1/2
G 2 1/2
G3
G3
G3
G3

DN 2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G2
G2
G2
G 2 1/2
G 2 1/2
G 2 1/2
G 2 1/2

mm
H
876
876
876
876
876
876
876
876
876
876
926
926
926
926

h1
190
190
190
190
190
190
190
190
190
190
257
257
257
257

h2
187
187
187
187
187
187
187
193
193
193
284
284
284
284

L1
725
749
773
701
725
749
773
764
794
830
877
970
1008
1045

L2
347
371
395
323
347
371
295
386
416
446
486
524
561
599

m1

B2

250

625

600

870

625

600

B2

625

600

weight
Peso
kg
47
50
54
46
49
53
57
61
66
68
87
114
122
124

Dimensions not binding to be verified when ordering

L2

B
DN 2

h1

h2

DN 1

3.93.155

m1

B2

L1

Motor
Motore

TYPE
BS2V 2MXH 2001-ITT
BS2V 2MXH 2002-ITT
BS2V 2MXH 2003-ITT
BS2V 2MXH 2004-ITT
BS2V 2MXH 2005-ITT
BS2V 2MXH-F 3201/A-ITT
BS2V 2MXH-F 3202/A-ITT
BS2V 2MXH-F 3203/A-ITT
BS2V 2MXH-F 3204/A-ITT
BS2V 2MXH-F 4801/A-ITT
BS2V 2MXH-F 4802/A-ITT
BS2V 2MXH-F 4803/A-ITT

kW
1,1 x2
2,2 x2
3 x2
4 x2
5,5 x2
2,2 x2
4 x2
5,5 x2
7,5 x2
3 x2
5,5 x2
7,5 x2

HP
1,5 x2
3 x2
4 x2
5,5 x2
7,5 x2
3 x2
5,5 x2
7,5 x2
10 x2
4 x2
7,5 x2
10 x2

Connection
Collettori
A
2,7 x2
5,3 x2
6,6 x2
9,6 x2
10,9 x2
5,3 x2
9,6 x2
10,9 x2
14,3 x2
6,6 x2
10,9 x2
14,3 x2

DN 1
G3
G3
G3
G3
G3
100
100
100
100
125
125
125

DN 2
G 2 1/2
G 2 1/2
G 2 1/2
G 2 1/2
G 2 1/2
80
80
80
80
100
100
100

Dimensions not binding to be verified when ordering

544

weight
Peso

mm
H
926
926
926
926
926
1100
1180
1180
1180
1198
1198
1198

h1
215
215
225
225
247
306
298
298
298
298
298
298

h2
354
354
354
354
354
429
429
429
429
468
468
468

L1
977
977
1013
1048
1091
1164
1180
1274
1320
1250
1306
1367

L2
485
485
504
539
573
593
593
640
685
654
654
716

m1
870
870
870
870
870
990
1010
1065
1110
1010
1065
1110

750

750

kg

214
243
260
268
286

BS. MXH. ITT

Pressure boosting sets with 2 to 3 horizontal


multi-stage pumps with I-MAT frequency converter

Dimensions and weights


BS.. 3MXH 2,4,8

BS.. 3MXH 16

L2

L2

DN 2

H
h2

DN 1

h2

h1

h1

3.93.159

m1

m1

B2

L1

L1

B2

Motore
Motor

TYPE
BS3V 3MXH 204/A-ITT
BS3V 3MXH 205/A-ITT
BS3V 3MXH 206/B-ITT
BS3V 3MXH 403/A-ITT
BS3V 3MXH 404/A-ITT
BS3V 3MXH 405/B-ITT
BS3V 3MXH 406-ITT
BS3V 3MXH 803-ITT
BS3V 3MXH 804-ITT
BS3V 3MXH 805/A-ITT
BS3V 3MXH 1603/A-ITT
BS3V 3MXH 1604/A-ITT
BS3V 3MXH 1605/A-ITT
BS3V 3MXH 1606/A-ITT

kW
0,55 x3
0,75 x3
1,1 x3
0,55 x3
0,75 x3
1,1 x3
1,5 x3
1,1 x3
1,5 x3
1,8 x3
1,8 x3
3 x3
3,7 x3
4 x3

HP
0,75 x3
1 x3
1,5 x3
0,75 x3
1 x3
1,5 x3
2 x3
1,5 x3
2 x3
2,5 x3
2,5 x3
4 x3
5 x3
5,5 x3

Collettori
Connection
A
1,6 x3
2 x3
2,7 x3
1,6 x3
2 x3
2,7 x3
3,6 x3
2,7 x3
3,6 x3
4,3 x3
4,3 x3
6,6 x3
9,6 x3
9,6 x3

DN 1
G 2 1/2
G 2 1/2
G 2 1/2
G 2 1/2
G 2 1/2
G 2 1/2
G 2 1/2
G3
G3
G3
DN 100
DN 100
DN 100
DN 100

mm

DN 2
G2
G2
G2
G2
G2
G2
G2
G 21/2
G 21/2
G 21/2
DN 80
DN 80
DN 80
DN 80

H
913
913
913
913
913
913
913
913
913
913
963
963
963
963

h1
227
227
227
227
227
227
227
227
227
227
227
227
227
227

h2
193
193
193
193
193
193
193
193
193
193
321
321
321
321

L1
857
881
905
833
857
881
905
905
933
950
857
1008
1045
1083

L2
356
380
404
332
356
390
404
404
432
449
500
538
575
613

m1

B2

423

1000

950

810

1000

950

weight
Peso
kg
-

Dimensions not binding to be verified when ordering

L2

B
DN 2

h1

h2

DN 1

3.93.155

m1

B2

L1

Motor
Motore

TYPE
BS3V 3MXH 2001-ITT
BS3V 3MXH 2002-ITT
BS3V 3MXH 2003-ITT
BS3V 3MXH 2004-ITT
BS3V 3MXH 2005-ITT
BS3V 3MXH-F 3201/A-ITT
BS3V 3MXH-F 3202/A-ITT
BS3V 3MXH-F 3203/A-ITT
BS3V 3MXH-F 3204/A-ITT
BS3V 3MXH-F 4801/A-ITT
BS3V 3MXH-F 4802/A-ITT
BS3V 3MXH-F 4803/A-ITT

kW
1,1 x3
2,2 x3
3 x3
4 x3
5,5 x3
2,2 x3
4 x3
5,5 x3
7,5 x3
3 x3
5,5 x3
7,5 x3

HP
1,5 x3
3 x3
4 x3
5,5 x3
7,5 x3
3 x3
5,5 x3
7,5 x3
10 x3
4 x3
7,5 x3
10 x3

Connection
Collettori
A
2,7 x3
5,3 x3
6,6 x3
9,6 x3
10,9 x3
5,3 x3
9,6 x3
10,9 x3
14,3 x3
6,6 x3
10,9 x3
14,3 x3

DN 1
100
100
100
100
100
125
125
125
125
150
150
150

DN 2
80
80
80
80
80
100
100
100
100
125
125
125

Dimensions not binding to be verified when ordering

545

weight
Peso

mm
H
963
963
963
963
963
1100
1180
1180
1180
1198
1198
1198

h1
215
215
225
225
247
306
298
298
298
316
316
316

h2
391
391
391
391
391
442
442
442
442
480
480
480

L1
991
991
1027
1062
1105
1164
1180
1274
1320
1272
1320
1381

L2
499
499
518
553
587
593
593
630
685
668
668
750

m1
810
810
810
810
995
1010
1065
1065
1110
1010
1065
1110

B2

1000

950

kg
-

51
1200 1200

BS. MXVB. ITT

Pressure boosting sets with 2 to 3 vertical


multi-stage pumps with I-MAT frequency converter

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

20

30
20

40

50

30

60

40

50

140

U.S. g.p.m.

Imp. g.p.m.

30

40
30

50

60

40

70

50

80

60

90
70

100
80

110
90

140

1-3MXV-B 25

400

120

1-3MXV-B 32

120

100

400

100
300

10

80

300
80

ft

ft

60

200

60

40

200

40

100

20

10

100

20

0
0

m 3/h
Q l/min

3
50

6
100

9
150

0
15
250

12
200

0
0

6
m3/h
Q l/min
100

12
200

18
300

24
400

72.951.1C

0 U.S. g.p.m. 40
0 Imp. g.p.m.

60
40

80
60

100
80

120

140

100

160

120

27

72.951.2C

180

140

U.S. g.p.m.

Imp. g.p.m.

100

200
100

150

300
200

250

140

140

1-3MXV-B 40

400

120

1-3MXV-B 50

120

400
ft

100

100

10

10

300

80

80

ft

8
H

200

60

ft

5
40

4
100

100

3
20

20

200

5
40

300

0
0

/h
Qm
l/min
3

12
200

18
300

24
400

30
500

36
600

0
42
700
72.951.3C

0
0

3
15
Q m /h 300

l/min

30

45
600

60
900

75
1200
72.953.1C

546

BS. MXVB. ITT

Pressure boosting sets with 2 to 3 vertical


multi-stage pumps with I-MAT frequency converter

Dimensions
and weights

H
DN 2

h2
h1
B

m1

Motore
Motor

TYPE
BS2V 2MXV-B 25-203-ITT
BS2V 2MXV-B 25-204-ITT
BS2V 2MXV-B 25-205-ITT
BS2V 2MXV-B 25-206-ITT
BS2V 2MXV-B 25-207-ITT
BS2V 2MXV-B 25-208-ITT
BS2V 2MXV-B 25-210-ITT
BS2V 2MXV-B 32-403-ITT
BS2V 2MXV-B 32-404-ITT
BS2V 2MXV-B 32-405-ITT
BS2V 2MXV-B 32-406-ITT
BS2V 2MXV-B 32-407-ITT
BS2V 2MXV-B 32-408/A-ITT
BS2V 2MXV-B 32-410/A-ITT
BS2V 2MXV-B 40-803-ITT
BS2V 2MXV-B 40-804-ITT
BS2V 2MXV-B 40-805/A-ITT
BS2V 2MXV-B 40-806/A-ITT
BS2V 2MXV-B 40-807/A-ITT
BS2V 2MXV-B 40-808/A-ITT
BS2V 2MXV-B 40-810/A-ITT

kW
0,75 x2
0,75 x2
0,75 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
0,75 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
2,2 x2
2,2 x2
1,1 x2
1,5 x2
2,2 x2
2,2 x2
3 x2
3 x2
3,7 x2

B2

L2

L1

HP
1 x2
1 x2
1 x2
1,5 x2
1,5 x2
2 x2
2 x2
1 x2
1,5 x2
1,5 x2
2 x2
2 x2
3 x2
3 x2
1,5 x2
2 x2
3 x2
3 x2
4 x2
4 x2
5 x2

Collettori
Connection
DN 1
A
DN 2
1,9 x2
1,9 x2
1,9 x2
2,7 x2
G 1 1/2 G 1 1/2
2,7 x2
4,3 x2
4,3 x2
1,9 x2
2,7 x2
2,7 x2
G2
G2
4,3 x2
4,3 x2
5,3 x2
5,3 x2
2,7 x2
4,3 x2
5,3 x2
G 2 1/2 G 2 1/2
5,3 x2
6,6 x2
6,6 x2
9,6 x2

B3

weight
Peso

mm
H

h1

h2

L1

L2

m1

B2

B3

887

148

224

336

287

332

600

625

185

887

148

239

336

287

332

600

625

185

887

153

266

391

324

332

600

625

185

kg
105
107
109
111
118

108
111
115
118
121

116
119
121
143
145

Dimensions not binding to be verified when ordering

H
DN 2
DN 1
h2
h1
B

m1

Motore
Motor

TYPE
BS3V 3MXV-B 25-203-ITT
BS3V 3MXV-B 25-204-ITT
BS3V 3MXV-B 25-205-ITT
BS3V 3MXV-B 25-206-ITT
BS3V 3MXV-B 25-207-ITT
BS3V 3MXV-B 25-208-ITT
BS3V 3MXV-B 25-210-ITT
BS3V 3MXV-B 32-403-ITT
BS3V 3MXV-B 32-404-ITT
BS3V 3MXV-B 32-405-ITT
BS3V 3MXV-B 32-406-ITT
BS3V 3MXV-B 32-407-ITT
BS3V 3MXV-B 32-408/A-ITT
BS3V 3MXV-B 32-410/A-ITT
BS3V 3MXV-B 40-803-ITT
BS3V 3MXV-B 40-804-ITT
BS3V 3MXV-B 40-805/A-ITT
BS3V 3MXV-B 40-806/A-ITT
BS3V 3MXV-B 40-807/A-ITT
BS3V 3MXV-B 40-808/A-ITT
BS3V 3MXV-B 40-810/A-ITT

kW
0,75 x3
0,75 x3
0,75 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
0,75 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
2,2 x3
2,2 x3
1,1 x3
1,5 x3
2,2 x3
2,2 x3
3 x3
3 x3
3,7 x3

B2

L2

L1

HP
1 x3
1 x3
1 x3
1,5 x3
1,5 x3
2 x3
2 x3
1 x3
1,5 x3
1,5 x3
2 x3
2 x3
3 x3
3 x3
1,5 x3
2 x3
3 x3
3 x3
4 x3
4 x3
5 x3

Collettori
Connection
DN 1
A
DN 2
1,9 x3
1,9 x3
1,9 x3
2,7 x3
G2
G2
2,7 x3
4,3 x3
4,3 x3
1,9 x3
2,7 x3
2,7 x3
4,3 x3 G 2 1/2 G 2 1/2
4,3 x3
5,3 x3
5,3 x3
2,7 x3
4,3 x3
5,3 x3
G3
G3
5,3 x3
6,6 x3
6,6 x3
9,6 x3

B3

weight
Peso

mm
H

h1

h2

L1

L2

m1

B2

B3

914

175

257

311,5

305,5

373

950

1010

225

914

175

275

344,5

287,5

373

950

1010

225

914

Dimensions not binding to be verified when ordering

547

180

300

402,5

329,5

373

950

1010

225

kg
105
107
109
111
118

108
111
115
118
121

116
119
121
143
145

51

BS. MXV. ITT

Pressure boosting sets with 2 to 3 vertical


multi-stage pumps with I-MAT frequency converter

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

20

30
20

40

50

30

60

40

50

140

U.S. g.p.m.

Imp. g.p.m.

30

40
30

50

60

40

70

50

80

60

90
70

100
80

110
90

140

1-3MXV 25

400

120

1-3MXV 32

120

100

400

100

12

12

300

300

10

80

80

ft

10

ft

60

200

60

40

200

40

100

20

100

20

0
0

m 3/h
Q l/min

3
50

6
100

9
150

0
15
250

12
200

0
0

6
m3/h
Q l/min
100

12
200

18
300

24
400

72.951.1C

0 U.S. g.p.m. 40
0 Imp. g.p.m.

60
40

80
60

100
80

120

140

100

160

120

27

72.951.2C

180

140

140

U.S. g.p.m.

Imp. g.p.m.

100

200
100

150

300
200

250

140

1-3MXV 40

1-3MXV 50-16

400

120

120

ft

8
11

100

100

10

300

300

80

400

80

ft

5
H

200

60

200

5
40

40

4
100

100
20

20

0
0

/h
Qm
l/min
3

12
200

18
300

24
400

30
500

36
600

0
42
700
72.951.3C

0
0

3
15
Q m /h 300

l/min

30

45
600

60
900

75
1200
72.953.1C

548

BS. MXV. ITT

Pressure boosting sets with 2 to 3 vertical


multi-stage pumps with I-MAT frequency converter

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

200

300
200

400

500

300

600

400

0 U.S. g.p.m. 200

500

0 Imp. g.p.m.

140

300

400
300

200

500
400

600

700

800

600

500

140

1-3MXV 65-32

1-3MXV 80-48

400

120

120

400

ft
100

100

300

80

80

m
200

200

60

4
3

40

40

100

100

20

H
ft

300

20

0
m 3/h
Q l/min
0
500

50

0
150
2500

100
1000

1500

2000

0 m3/h
40
Q
0 l/min 500

60
1000

80
100
1500

120
2000

140
160
2500

72.953.2C

U.S. g.p.m.

Imp. g.p.m.

500

72.953.3C

1000

0 U.S. g.p.m. 400

500

180
3000

1000

0 Imp. g.p.m.

140

600

400

800
600

1000
800

1200
1000

1400

1600

1200

140

1-3MXV 100-65

120

400

1-3MXV 100-90
120

400

5
5-2R

5-2R
100

100

4
80

300

4-2R

80

ft

H
ft

3-2R

40

40

2-2R

2-2R

100

100

20

4-2R

200

60

3-2R

300

m
200

60

20

0
0

60

m /h
Q l/min
1000
3

120
2000

180
3000

240
4000

0
280

72.951.2C

51
0 m3/h
80
Q
0 l/min 1000

120
2000

160
200
3000

240
4000

280
320
5000

360
6000
72.953.3C

549

BS. MXV. ITT

Pressure boosting sets with 2 to 3 vertical


multi-stage pumps with I-MAT frequency converter

Dimensions
and weights

DN 2
DN 1

h2
h1

m1
L1

Motore
Motor

TYPE
BS2V 2MXV 25-204/C-ITT
BS2V 2MXV 25-205/C-ITT
BS2V 2MXV 25-206/C-ITT
BS2V 2MXV 25-207/C-ITT
BS2V 2MXV 25-208/C-ITT
BS2V 2MXV 25-210/C-ITT
BS2V 2MXV 25-212/C-ITT
BS2V 2MXV 32-404/C-ITT
BS2V 2MXV 32-405/C-ITT
BS2V 2MXV 32-406/C-ITT
BS2V 2MXV 32-407/C-ITT
BS2V 2MXV 32-408/C-ITT
BS2V 2MXV 32-410/C-ITT
BS2V 2MXV 32-412/C-ITT
BS2V 2MXV 40-804/C-ITT
BS2V 2MXV 40-805/C-ITT
BS2V 2MXV 40-806/C-ITT
BS2V 2MXV 40-807/C-ITT
BS2V 2MXV 40-808/C-ITT
BS2V 2MXV 40-810/C-ITT
BS2V 2MXV 40-811/C-ITT

kW
0,75 x2
0,75 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
2,2 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
2,2 x2
2,2 x2
3 x2
1,5 x2
2,2 x2
2,2 x2
3 x2
3 x2
4 x2
4 x2

B2

L2

HP
1 x2
1 x2
1,5 x2
1,5 x2
2 x2
2 x2
3 x2
1,5 x2
1,5 x2
2 x2
2 x2
3 x2
3 x2
4 x2
2 x2
3 x2
3 x2
4 x2
4 x2
5,5 x2
5,5 x2

Collettori
Connection
DN 1
A
DN 2
1,9 x2
1,9 x2
2,7 x2
2,7 x2
G 1 1/2 G 1 1/2
4,3 x2
4,3 x2
5,3 x2
2,7 x2
2,7 x2
4,3 x2
G2
G2
4,3 x2
5,3 x2
5,3 x2
6,6 x2
4,3 x2
5,3 x2
5,3 x2
G 2 1/2 G 2 1/2
6,6 x2
6,6 x2
9,6 x2
9,6 x2

B3

weight
Peso

mm
H

h1

h2

L1

L2

m1

B2

B3

887

148

224

336

287

332

600

625

185

887

148

239

336

287

332

600

625

185

887

153

266

391

324

332

600

625

185

B2

B3

kg
105
107
109
111
118

108
111
115
118
121

116
119
121
143
145

Dimensions not binding to be verified when ordering

DN 2
DN 1
h2
h1

m1
L1

Motore
Motor

TYPE
BS3V 3MXV 25-204/C-ITT
BS3V 3MXV 25-205/C-ITT
BS3V 3MXV 25-206/C-ITT
BS3V 3MXV 25-207/C-ITT
BS3V 3MXV 25-208/C-ITT
BS3V 3MXV 25-210/C-ITT
BS3V 3MXV 25-212/C-ITT
BS3V 3MXV 32-404/C-ITT
BS3V 3MXV 32-405/C-ITT
BS3V 3MXV 32-406/C-ITT
BS3V 3MXV 32-407/C-ITT
BS3V 3MXV 32-408/C-ITT
BS3V 3MXV 32-410/C-ITT
BS3V 3MXV 32-412/C-ITT
BS3V 3MXV 40-804/C-ITT
BS3V 3MXV 40-805/C-ITT
BS3V 3MXV 40-806/C-ITT
BS3V 3MXV 40-807/C-ITT
BS3V 3MXV 40-808/C-ITT
BS3V 3MXV 40-810/C-ITT
BS3V 3MXV 40-811/C-ITT

kW
0,75 x3
0,75 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
2,2 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
2,2 x3
2,2 x3
3 x3
1,5 x3
2,2 x3
2,2 x3
3 x3
3 x3
4 x3
4 x3

B2

L2

HP
1 x3
1 x3
1,5 x3
1,5 x3
2 x3
2 x3
3 x3
1,5 x3
1,5 x3
2 x3
2 x3
3 x3
3 x3
4 x3
2 x3
3 x3
3 x3
4 x3
4 x3
5,5 x3
5,5 x3

B3

Collettori
Connection
DN 1
A
DN 2
1,9 x3
1,9 x3
2,7 x3
2,7 x3
G2
G2
4,3 x3
4,3 x3
5,3 x3
2,7 x3
2,7 x3
4,3 x3
4,3 x3 G 2 1/2 G 2 1/2
5,3 x3
5,3 x3
6,6 x3
4,3 x3
5,3 x3
5,3 x3
G3
G3
6,6 x3
6,6 x3
9,6 x3
9,6 x3

Dimensions not binding to be verified when ordering

550

weight
Peso

mm
H

h1

h2

L1

L2

m1

kg
105
107
109
111
118

914

175

257

311,5

305,5

373

950

1010

225

914

175

275

344,5

287,5

373

950

1010

225

108
111
115
118
121

914

180

300

402,5

329,5

373

950

1010

225

116
119
121
143
145

BS. MXV. ITT

Pressure boosting sets with 2 to 3 vertical


multi-stage pumps with I-MAT frequency converter

Dimensions
and weights

DN 1

DN 2

h1
B

m1
L1

Motore
Motor

TYPE
BS2V 2MXV 50-1603/C-ITT
BS2V 2MXV 50-1604/C-ITT
BS2V 2MXV 50-1605/C-ITT
BS2V 2MXV 50-1606/C-ITT
BS2V 2MXV 50-1607/C-ITT
BS2V 2MXV 50-1608/C-ITT
BS2V 2MXV 65-3202/C-ITT
BS2V 2MXV 65-3203/C-ITT
BS2V 2MXV 65-3204/C-ITT
BS2V 2MXV 65-3205/D-ITT
BS2V 2MXV 65-3206/D-ITT
BS2V 2MXV 80-4801/C-ITT
BS2V 2MXV 80-4802/C-ITT
BS2V 2MXV 80-4803/C-ITT
BS2V 2MXV 80-4804/D-ITT
BS2V 2MXV 100-6501-ITT
BS2V 2MXV 100-6502-2R-ITT
BS2V 2MXV 100-6502-ITT
BS2V 2MXV 100-9001-1R-ITT
BS2V 2MXV 100-9001-ITT
BS2V 2MXV 100-9002-2R-ITT

kW
3 x2
4 x2
5,5 x2
5,5 x2
7,5 x2
7,5 x2
4 x2
5,5 x2
7,5 x2
11 x2
11 x2
4 x2
5,5 x2
7,5 x2
11 x2
5,5 x2
7,5 x2
11 x2
5,5 x2
7,5 x2
11 x2

HP
4 x2
5,5 x2
7,5 x2
7,5 x2
10 x2
10 x2
5,5 x2
7,5 x2
10 x2
15 x2
15 x2
5,5 x2
7,5 x2
10 x2
15 x2
7,5 x2
10 x2
15 x2
7,5 x2
10 x2
15 x2

Collettori
Connection
DN 1
A
6,6 x2
9,6 x2
10,9 x2
G3
10,9 x2
14,3 x2
14,3 x2
9,6 x2
10,9 x2
100
14,3 x2
21,5 x2
21,5 x2
9,6 x2
10,9 x2
125
14,3 x2
21,5 x2
10,9 x2
14,3 x2 150
21,5 x2
10,9 x2
14,3 x2 200
21,5 x2

Dimensions not binding to be verified when ordering

B4
B2

L2

B3

weight
Peso

mm
H
841
876
958
993
1027
1062
853
947
993
1189
1235
857
940
1001
1212

DN 2

G3

100

125

h1

L1

L2

m1

B2

B3

B4

225

455

355

550

700

950

160

200

kg
-

160
240

560

550

425

750

200

950
170
160

240

640

550

500

750

950

200
170

150

550

950

200

550

950

* Dimensions on request

H
DN 1

DN 2

h1
m1
L1

Motor
Motore

TYPE
BS3V 3MXV 50-1603/C-ITT
BS3V 3MXV 50-1604/C-ITT
BS3V 3MXV 50-1605/C-ITT
BS3V 3MXV 50-1606/C-ITT
BS3V 3MXV 50-1607/C-ITT
BS3V 3MXV 50-1608/C-ITT
BS3V 3MXV 65-3202/C-ITT
BS3V 3MXV 65-3203/C-ITT
BS3V 3MXV 65-3204/C-ITT
BS3V 3MXV 65-3205/D-ITT
BS3V 3MXV 65-3206/D-ITT
BS3V 3MXV 80-4801/C-ITT
BS3V 3MXV 80-4802/C-ITT
BS3V 3MXV 80-4803/C-ITT
BS3V 3MXV 80-4804/D-ITT
BS3V 3MXV 100-6501-ITT
BS3V 3MXV 100-6502-2R-ITT
BS3V 3MXV 100-6502-ITT
BS3V 3MXV 100-9001-1R-ITT
BS3V 3MXV 100-9001-ITT
BS3V 3MXV 100-9002-2R-ITT

kW
3 x3
4 x3
5,5 x3
5,5 x3
7,5 x3
7,5 x3
4 x3
5,5 x3
7,5 x3
11 x3
11 x3
4 x3
5,5 x3
7,5 x3
11 x3
5,5 x3
7,5 x3
11 x3
5,5 x3
7,5 x3
11 x3

L2

HP
4 x3
5,5 x3
7,5 x3
7,5 x3
10 x3
10 x3
5,5 x3
7,5 x3
10 x3
15 x3
15 x3
5,5 x3
7,5 x3
10 x3
15 x3
7,5 x3
10 x3
15 x3
7,5 x3
10 x3
15 x3

Connection
Collettori
DN 1
A
6,6 x3
9,6 x3
10,9 x3
100
10,9 x3
14,3 x3
14,3 x3
9,6 x3
10,9 x3
125
14,3 x3
21,5 x3
21,5 x3
9,6 x3
10,9 x3
150
14,3 x3
21,5 x3
10,9 x3
14,3 x3 200
21,5 x3
10,9 x3
14,3 x3 250
21,5 x3

Dimensions not binding to be verified when ordering

B4
B3

B2

100

weight
Peso

mm

DN 2

1210

h1

L1

L2

m1

B2

B3

B4

276

470

370

550

1200

1400

160

200

kg
-

160
125
1210

291

580

462

550

1200

1400

1210

291

683

500

550

1200

1400

170

200

160
150

200
170

200

550

1500

250

550

1500

* Dimensions on request

551

51

BS. NM. ITT

Pressure boosting sets with 2 to 3 Centrifugal Pumps


multi-stage pumps with I-MAT frequency converter

Coverage chart
50

40

1-3NM 3/CE

1-3NM 3/BE

38

45

36
H m

H m

40
34

35

32
30

30

25

28
0 Q m 3/h

10

15

0 Q m 3/h

20

10 12 14 16 18 20 22 24 26

32

60

1-3NM 25/160BE

55

30

50

28
H m

H m

1-3NM 3/CE

45

26
24

40

22

35
0 Q 2m 3/h4

0 Q m 3/h 5

10 12 14 16 18 20 22 24 26

40

10

15

20

25

30

44

1-3NM 25/160AE

1-3NM 25/20B/B
42

35
H m

H m

40
38

30
36
25

34
0 Q m 3/h

10

20

30

40

0 Q m 3/h

10

20

30

40

60

52

1-3NM 25/20A/B

50

1-3NM 25/20S/B

48

55
H m

H m

46
44

50

42
40

45

38
0

Q m 3/h

10

20

30

40

50

552

10
Q m 3/h

20

30

40

50

60

BS. NM. ITT

Pressure boosting sets with 2 to 3 Centrifugal Pumps


multi-stage pumps with I-MAT frequency converter

Coverage chart
38

32

1-3NM 32/16BE

1-3NM 32/16A/A

37

30

36
35

26

H m

H m

28

24

34
33
32

22

31
30

20
0 Q m 3/h 10

20

30

40

50

42

Q m 3/h

10

20

30

40

50

48

1-3NM 32/20D/A

1-3NM 32/20C/A

46

40

44

38
H m

H m

42
36
34

40
38

32

36

30

34
0 Q m 3/h

10

20

30

40

0 Q m 3/h 10

20

30

40

50

26

60

1-3NM 32/20A/A

1-3NM 40/16C/B

24

58

22
20

54

H m

H m

56

52

18
16
14

50

12
10

48
0 Q m 3/h 10

20

32
30
28

30

40

0 Q m 3/h20

50

60

80

100

120

40

1-3NM 40/16B/B

1-3NM 40/16A/B
35

26
24
22

30
H m

H m

40

20
18
16
14
12

25

51
20

10

15
0 Q m 320
/h

40

60

80

100

120

140

0 Q m 3/h

553

50

100

150

BS. NM. ITT

Pressure boosting sets with 2 to 3 Centrifugal Pumps


multi-stage pumps with I-MAT frequency converter

Coverage chart
44

42

1-3NM 40/20D/A

38

1-3NM 40/20C/A
42

34
40

26

H m

H m

30

22

38
36

18
34

14

32

10
0 Q m 3/h20

40

60

80

100

0 Q m 3/h

120

55

20

30

40

60

70

80

90

58

1-3NM 40/20C/A

1-3NM 40/20AR/A

50

56

45

54

H m

H m

50

40
35

52
50

30

48
0

20
Q m 3/h

40

60

80

100

120

0 Q m 3/h

20

30

40

50

60

70

80

90

65

60

1-3NM 40/20A/A

1-3NM 40/25C/C

60

55
55
50

H m

H m

50
45

45
40

40

35
30

35
0 Q m 3/h

40

60

80

100

120

0 Q m 3/h

140

75

40

60

80

100

120

140

35

1-3NM 40/25B/C

70

1-3NM 50/16B/B
30

65

25

H m

H m

60
55

20
15

50

10

45
40
0 Q m 3/h

40

60

80

100

120

140

0 Q m 3/h 50

554

100

150

200

250

BS. NM. ITT

Pressure boosting sets with 2 to 3 Centrifugal Pumps


multi-stage pumps with I-MAT frequency converter

Coverage chart
50

45

45

35

40

30

35

H m

H m

1-3NM 50/16A/B
40

25

30

20

25

1-3NM 50/20B/C

20

15
0 Q m 3/h 50

100

150

200

250

60

Q m 3/h

50

100

150

200

250

60

1-3NM 50/20A/C

1-3NM 50/25C/C

55

55

50
45

45

H m

H m

50

40

40
35
30

35

25

30

20
0 Q m 3/h 50

100

150

200

250

0 Q m 3/h 40

26

60

80 100 120 140 160 180 200 220

30

1-3NM 65/16D/B

1-3NM 65/16C/C

28

24

26
24

H m

H m

22
20

22
20

18
18
16

16
0 Q m 3/h

100

200

300

400

0 Q m 3/h

34

100

200

300

400

24

1-3NM 65/16B/C

32

1-3NM 80/16E/B

22
20

30

H m

H m

18
28
26

16

51

14

24

12

22

10
0

Q m 3/h

100

200

300

400

0 Q m 3/h 100

555

200

300

400

500

BS. NM. ITT

Pressure boosting sets with 2 to 3 Centrifugal Pumps


multi-stage pumps with I-MAT frequency converter

Coverage chart
28

30

1-3NM 80/16D/C

1-3NM 80/16C/C

28

24

26

22

24

H m

H m

26

20

22

18

20

16

18

14

16
0 Q m 3/h 100

200

300

400

500

0 Q m 3/h100

556

200

300

400

500

600

BS. NM. ITT

Pressure boosting sets with 2 to 3 Centrifugal Pumps


multi-stage pumps with I-MAT frequency converter

Dimensions

DN 2

DN 1
h2

h1

L1

L2

B2

m1

Motor
Motore

TYPE

BS2V 2NM 3/CE-ITT


BS2V 2NM 3/BE-ITT
BS2V 2NM 3/A/A-ITT
BS2V 2NM 25/160BE-ITT
BS2V 2NM 25/160AE-ITT
BS2V 2NM 25/20B/B-ITT
BS2V 2NM 25/20A/B-ITT
BS2V 2NM 25/20S/B-ITT
BS2V 2NM32/16BE-ITT
BS2V 2NM32/16A/A-ITT
BS2V 2NM32/20D/A-ITT
BS2V 2NM32/20C/A-ITT
BS2V 2NM32/20A/A-ITT
BS2V 2NM40/16C/B-ITT
BS2V 2NM40/16B/B-ITT
BS2V 2NM40/16A/B-ITT
BS2V 2NM40/20D/A-ITT
BS2V 2NM40/20C/A-ITT
BS2V 2NM40/20B/A-ITT
BS2V 2NM40/20AR/A-ITT
BS2V 2NM40/20A/A-ITT
BS2V 2NM40/25C/C-ITT
BS2V 2NM40/25B/C-ITT
BS2V 2NM50/16B/B-ITT
BS2V 2NM50/16A/B-ITT
BS2V 2NM50/20B/C-ITT
BS2V 2NM50/20A/C-ITT
BS2V 2NM50/25C/C-ITT
BS2V 2NM65/16D/B-ITT
BS2V 2NM65/16C/C-ITT
BS2V 2NM65/16B/C-ITT
BS2V 2NM80/16E/B-ITT
BS2V 2NM80/16D/C-ITT
BS2V 2NM80/16C/C-ITT

kW
1,1 x2
1,5 x2
2,2 x2
1,1 x2
1,5 x2
2,2 x2
3 x2
4 x2
1,5 x2
2,2 x2
2,2 x2
3 x2
4 x2
2,2 x2
3 x2
4 x2
4 x2
4 x2
5,5 x2
5,5 x2
7,5 x2
9,2 x2
11 x2
5,5 x2
7,5 x2
9,2 x2
11 x2
11 x2
7,5 x2
9,2 x2
11 x2
7,5 x2
9,2 x2
11 x2

HP
1,5 x2
2 x2
3 x2
1,5 x2
2 x2
3 x2
4 x2
5,5 x2
2 x2
3 x2
3 x2
4 x2
5,5 x2
3 x2
4 x2
5,5 x2
5,5 x2
5,5 x2
7,5 x2
7,5 x2
10 x2
12,5 x2
15 x2
7,5 x2
10 x2
12,5 x2
15 x2
15 x2
10 x2
12,5 x2
15 x2
10 x2
12,5 x2
15 x2

Connection
Collettori
DN 1
A
2,7 x2
G2
4,3 x2
5,3 x2
2,7 x2
G2
4,3 x2
5,3 x2
6,6 x2 G 2 1/2
9,6 x2
3,5 x2
G3
5 x2
5 x2
G3
6,4 x2
8,3 x2
5 x2
100
6,4 x2
8,3 x2
8,3 x2
8,3 x2
12,5 x2 100
12,5 x2
16 x2
19 x2
100
22,5 x2
12,5 x2
125
16 x2
19 x2
125
22,5 x2
22,5 x2 125
16 x2
200
19 x2
22,5 x2
16 x2
250
19 x2
22,5 x2

DN 2
G 1 1/2
G 1 1/2
G2
G 2 1/2
G 2 1/2

80

80

80
100
100
100
150

200

mm
H
876
876
876
876
876
876
883
883
876
876
876
876
876
897
897
897
897
897
897
897
897
977
977
977
977
977
977
977
977
977
977
977
977
977

h1

h2

L1

146

325

267

135

305

273

160
165
165
165
165
195
195
195
187
187
187
215
215
215
215
215
340
340
315
215
315
215
340
320
320
220
340
340
340

330

373

345

385

365

385

380

480

400

500

440

500

435

515

455

515

480

515

525

625

615

730

L2
325
325
365

m1

B2

235

600

625

324

235

600

625

370
397
397
330
370
370
395
395
370
395
395
395
395
425
425
425
540
590
425
425
540
590
595
425
540
590
445
570
620

235
265
265

600

625

235

600

625

235

600

625

550

820

800

550

820

800

820

820

820

1020

1050

weight
Peso
kg

Dimensions not binding to be verified when ordering

51

557

BS. NM. ITT

Pressure boosting sets with 2 to 3 Centrifugal Pumps


multi-stage pumps with I-MAT frequency converter

Dimensions

DN 2

DN 1
h2

h1

L1

L2

B2

m1

Motor
Motore

TYPE

BS3V 3NM 3/CE-ITT


BS3V 3NM 3/BE-ITT
BS3V 3NM 3/A/A-ITT
BS3V 3NM 25/160BE-ITT
BS3V 3NM 25/160AE-ITT
BS3V 3NM 25/20B/B-ITT
BS3V 3NM 25/20A/B-ITT
BS3V 3NM 25/20S/B-ITT
BS3V 3NM32/16BE-ITT
BS3V 3NM32/16A/A-ITT
BS3V 3NM32/20D/A-ITT
BS3V 3NM32/20C/A-ITT
BS3V 3NM32/20A/A-ITT
BS3V 3NM40/16C/B-ITT
BS3V 3NM40/16B/B-ITT
BS3V 3NM40/16A/B-ITT
BS3V 3NM40/20D/A-ITT
BS3V 3NM40/20C/A-ITT
BS3V 3NM40/20B/A-ITT
BS3V 3NM40/20AR/A-ITT
BS3V 3NM40/20A/A-ITT
BS3V 3NM40/25C/C-ITT
BS3V 3NM40/25B/C-ITT
BS3V 3NM50/16B/B-ITT
BS3V 3NM50/16A/B-ITT
BS3V 3NM50/20B/C-ITT
BS3V 3NM50/20A/C-ITT
BS3V 3NM50/25C/C-ITT
BS3V 3NM65/16D/B-ITT
BS3V 3NM65/16C/C-ITT
BS3V 3NM65/16B/C-ITT
BS3V 3NM80/16E/B-ITT
BS3V 3NM80/16D/C-ITT
BS3V 3NM80/16C/C-ITT

kW
1,1 x3
1,5 x3
2,2 x3
1,1 x3
1,5 x3
2,2 x3
3 x3
4 x3
1,5 x3
2,2 x3
2,2 x3
3 x3
4 x3
2,2 x3
3 x3
4 x3
4 x3
4 x3
5,5 x3
5,5 x3
7,5 x3
9,2 x3
11 x3
5,5 x3
7,5 x3
9,2 x3
11 x3
11 x3
7,5 x3
9,2 x3
11 x3
7,5 x3
9,2 x3
11 x3

HP
1,5 x3
2 x3
3 x3
1,5 x3
2 x3
3 x3
4 x3
5,5 x3
2 x3
3 x3
3 x3
4 x3
5,5 x3
3 x3
4 x3
5,5 x3
5,5 x3
5,5 x3
7,5 x3
7,5 x3
10 x3
12,5 x3
15 x3
7,5 x3
10 x3
12,5 x3
15 x3
15 x3
10 x3
12,5 x3
15 x3
10 x3
12,5 x3
15 x3

Connection
Collettori
A
2,7 x3
4,3 x3
5,3 x3
2,7 x3
4,3 x3
5,3 x3
6,6 x3
9,6 x3
3,5 x3
5 x3
5 x3
6,4 x3
8,3 x3
5 x3
6,4 x3
8,3 x3
8,3 x3
8,3 x3
12,5 x3
12,5 x3
16 x3
19 x3
22,5 x3
12,5 x3
16 x3
19 x3
22,5 x3
22,5 x3
16 x3
19 x3
22,5 x3
16 x3
19 x3
22,5 x3

DN 1

DN 2

G2

G2

G2

G2

G3

G 2 1/2

100

80

100

80

125

100

125

100

125

100

150

125

150

125

150

125

250

200

300

250

Dimensions not binding to be verified when ordering

558

mm
H
876
876
876
876
876
876
883
883
876
876
876
876
876
897
897
897
897
897
897
897
897
977
977
977
977
977
977
977
977
977
977
977
977
977

h1

h2

L1

146

316

135

290

316

390

495

410

515

450

515

448

525

468

525

493

525

555

650

645

755

160
165
165
165
165
195
195
195
187
187
187
215
215
215
215
215
340
340
315
215
315
215
340
320
320
220
340
340
340

L2
325
325
365
324
370
397
397
330
370
370
395
395
370
395
395
395
395
425
425
425
540
590
425
425
540
590
595
425
540
590
445
570
620

m1

B2

423

950

1000

423

950

1000

423

950

1000

950

950

1340

1340

1340

1340

1340

1340

1540

1600

weight
Peso
kg

2 MX.., 2 NM, 2 NMD, 2 NG..


Pressure boosting sets for domestic use with two electric pumps
Fixed speed pump or Variable speed pump (frequency converter)

Construction
Automatic pressure boosting plant consisting of two pumps complete with ball, non return valve on the suction side and ball valves on the discharge
side.
Suction and delivery manifolds are in AISI 304 stainless steel.
Connections are located on the delivery manifold for the installation of two 20 litres cylindrical vessels.
Electrical control boards:
- with microprocessor for fixed speed pump units (see page 486).
- with frequency converter for variable speed pump units (see page 487).
The unit includes one pressure gauge and two adjustable differential pressure switches or pressure transducer (for sets with frequency converter).

Operation
BS 2F

Fixed speed pump


Depending on the reduction of the pressure in the system, the pressure switches determine the starting up of the pumps in sequence and the
microprocessor alternates the starts.

BS1V1F

Pumps at variable speed with one frequency converter


According to the water consumption, one or more pumps start, one at variable speed and the others at fixed speed, to grant the water
quantity required at the set pressure.

BS2V

Pumps at variable speed with two frequency converter


Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the set pressure.

Applications
For drawing water out a well.
As pressure boosting pump to increase water pressure when needed (follow local rules).

Motors
2-pole induction motors, 50 Hz, n 2900 rpm.
- Three-phase 230/400V 10% up to 3 kW, suitable for operation with frequency converter;
400/690V 10% for 4 kW, suitable for operation with frequency converter;
- Single-phase 230 V 10%, with thermal protector.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.

Vessels (on request)


Cylindrical with capacity 20 litres, membrane type, air precharged.

559

51

2 MGP

Systems with two Multi-Stage stainless steel pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0 U.S. g.p.m.

20

0 Imp. g.p.m. 10

30

40

20

0 U.S. g.p.m.

30

20

0 Imp. g.p.m. 10

40

50

30

40

20

30

40

50
150

MGP 203

40
H
m
30

150

MGP 204

40
H
m
30

ft
100

20

ft
100

20
50

50

10
0

10

0
m3/h 2
0 Q l/min 40

4
80

10
160

120

0
m3/h 2
0 Q l/min 40

4
80

120

72.1145.1

0 U.S. g.p.m.

20

0 Imp. g.p.m. 10

30

72.1145.2

40

20

0 U.S. g.p.m. 20

30

10
160

40

50

60

Imp. g.p.m.

40
20

60
40
150

MGP 205

50
H
m
40

ft

40
H
m
30

100

20

150

30

MGP 403

ft
100

50
10

20
50
10

0
m3/h 2
0 Q l/min 40

4
80

10
160

120

0
0

3
Q m /h
l/min

0
16

12
200

100

72.1145.1

0 U.S. g.p.m. 20
50

Imp. g.p.m.

40

72.1145.3

60

0 U.S. g.p.m. 20

40

20

60

Imp. g.p.m.

40

60
40

20

150

MGP 404

40
H
m
30

MGP 405

50
H
m
40

ft
100

20

150
ft
100

30
50

10

20
50

0
0

3
Q m /h
l/min

8
100

12
200

10

0
16
72.1145.4

0
0

3
Q m /h
l/min

8
100

12
200

16
72.1145.4

560

2 MGP

Systems with two Multi-Stage stainless steel pumps


Fixed speed pump or Variable speed pump (frequency converter)

Characteristic, dimensions and weights

L2
DN 2
H
DN 1

h2

h1
4.93.315

m1
L1

BS2F
Mains: 400V 3~
3~
Motor: 400V 3~
BS2F 2MGP 203
BS2F 2MGP 204
BS2F 2MGP 205
BS2F 2MGP 403
BS2F 2MGP 404
BS2F 2MGP 405

B2

BSM2F
Mains: 230V 1~
1~
Motor:
230V 1~
BSM2F 2MGPM 203
BSM2F 2MGPM 204
BSM2F 2MGPM 205
BSM2F 2MGPM 403
BSM2F 2MGPM 404
BSM2F 2MGPM 405

Motor
kW
HP
0,45+0,45 0,6+0,6
0,55+0,55 0,75+0,75
0,75+0,75
1+1
0,55+0,55 0,75+0,75
0,75+0,75
1+1
1,1+1,1
1,5+1,5

Q
max*
l/min
155
160
160
230
220
220

Pres. switch setting


bar
1,42,6
2,03,2
3,04,5
1,22,4
2,43,6
3,04,5

bar
1,02,2
1,52,7
2,54,0
0,92,1
2,03,2
2,54,0

Manifolds
DN1
G2
G2
G2
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
840
840
840
840
840
840

h1
151
151
151
151
151
151

h2
206
206
206
206
206
206

L1
793
793
793
793
793
793

L2
355
355
355
355
355
355

m1

235

Weight
kg
41
46
52
625 600
46
48
54
B2

Vessel
Mem. Vessel
litre litre
24x2 100
24x2 100
24x2 100
24x2 100
80 200
80 200

* Maximum pumps flow at minimum set pressure of 2 nd pressure switch.

BS1V1F

BSM1V1F

Mains: 400V 3~
3~
Motor:
400V 3~

Mains: 230V 1~
1~
Motor: 230V 3~ and 230V 1~

BS1V1F 2MGP 203


BS1V1F 2MGP 204
BS1V1F 2MGP 205
BS1V1F 2MGP 403
BS1V1F 2MGP 404
BS1V1F 2MGP 405

BSM1V1F 2MGP 203


BSM1V1F 2MGP 204
BSM1V1F 2MGP 205
BSM1V1F 2MGP 403
BSM1V1F 2MGP 404
BSM1V1F 2MGP 405

BS2V

Motor
kW
0,45+0,45
0,55+0,55
0,75+0,75
0,55+0,55
0,75+0,75
1,1+1,1

Manifolds
HP
0,6+0,6
0,75+0,75
1+1
0,75+0,75
1+1
1,5+1,5

DN1
G2
G2
G2
G2
G2
G2

HP
0,6+0,6
0,75+0,75
1+1
0,75+0,75
1+1
1,5+1,5

DN1
G2
G2
G2
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
1100
1100
1100
1100
1100
1100

h1
151
151
151
151
151
151

h2
206
206
206
206
206
206

L1
793
793
793
793
793
793

H
1100
1100
1100
1100
1100
1100

h1
151
151
151
151
151
151

h2
206
206
206
206
206
206

L1
793
793
793
793
793
793

L2
355
355
355
355
355
355

m1

235

Vessel
Weight Membrane
B2
B
litre
kg
24x2
41
24x2
46
24x2
52
625 600
24x2
46
24x2
48
24x2
54

BSM2V

Mains: 400V 3~
3~
Motor: 400V 3~

Mains: 230V 1~
1~
Motor: 230V 3~

BS2V 2MGP 203


BS2V 2MGP 204
BS2V 2MGP 205
BS2V 2MGP 403
BS2V 2MGP 404
BS2V 2MGP 405

BSM2V 2MGP 203


BSM2V 2MGP 204
BSM2V 2MGP 205
BSM2V 2MGP 403
BSM2V 2MGP 404
BSM2V 2MGP 405

Motor
kW
0,45+0,45
0,55+0,55
0,75+0,75
0,55+0,55
0,75+0,75
1,1+1,1

Manifolds

561

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
L2
355
355
355
355
355
355

m1

235

Vessel
Weight Membrane
litre
kg
24x2
41
24x2
46
24x2
52
625 600
24x2
46
24x2
48
24x2
54
B2

51

2 MXP

Systems with two Multi-Stage stainless steel pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0 U.S. g.p.m.

20

0 Imp. g.p.m. 10

30

40

20

0 U.S. g.p.m.

30

20

0 Imp. g.p.m. 10

40

50

30

40

20

30

40

50
150

MXP 203

40
H
m
30

ft
100

20

150

MXP 204

40
H
m
30

ft
100

20
50

10

50
10

0
m3/h 2
0 Q l/min 40

4
80

10
160

120

0
m3/h 2
0 Q l/min 40

4
80

72.1145.1

0 U.S. g.p.m.

20

0 Imp. g.p.m. 10

30

72.1145.2

0 U.S. g.p.m. 20

40

20

30

10
160

120

40

50

60

Imp. g.p.m.

40
20

60
40
150

MXP 205

50
H
m
40

ft

40
H
m
30

100

20

150

30

MXP 403

ft
100

50
10

20
50
10

0
m3/h 2
0 Q l/min 40

4
80

10
160

120

0
0

3
Q m /h
l/min

0
16

12
200

100

72.1145.1

0 U.S. g.p.m. 20
50

Imp. g.p.m.

40
20

72.1145.3

60

0 U.S. g.p.m. 20

40

60

Imp. g.p.m.

40
20

60
40

150

MXP 404

40
H
m
30

ft
100

20

MXP 405

50
H
m
40

150
ft
100

30
50

10

20
50

0
0

3
Q m /h
l/min

8
100

12
200

10

0
16

0
0

3
Q m /h
l/min

8
100

12
200

16
72.1145.4

72.1145.4

562

2 MXP

Systems with two Multi-Stage stainless steel pumps


Fixed speed pump or Variable speed pump (frequency converter)

Characteristic, dimensions and weights

L2
DN 2
H
DN 1

h2

h1
4.93.315

m1
L1

BS2F

BSM2F

Mains: 400V 3~
3~
Motor:
400V 3~

Mains: 230V 1~
1~
Motor:
230V 1~

Motor

kW
HP
BS2F 2MXP 203
BSM2F 2MXPM 203 0,45+0,45 0,6+0,6
BS2F 2MXP 204/A BSM2F 2MXPM 204/A 0,55+0,55 0,75+0,75
BS2F 2MXP 205
BSM2F 2MXPM 205
0,75+0,75
1+1
BS2F 2MXP 403/A BSM2F 2MXPM 403/A 0,55+0,55 0,75+0,75
BS2F 2MXP 404/A BSM2F 2MXPM 404/A 0,75+0,75
1+1
BS2F 2MXP 405
BSM2F 2MXPM 405
1,1+1,1
1,5+1,5

B2

Q
max*
l/min
155
160
160
230
220
220

Pres. switch setting


bar
1,42,6
2,03,2
3,04,5
1,52,7
2,43,6
3,04,5

bar
1,02,2
1,52,7
2,54,0
1,22,4
2,03,2
3,54,0

Manifolds
DN1
G2
G2
G2
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
840
840
840
840
840
840

h1
151
151
151
151
151
151

h2
206
206
206
206
206
206

L1
793
793
793
793
793
793

L2
355
355
355
355
355
355

m1

235

Weight
kg
41
46
48
625 600
46
48
54
B2

Vessel
Mem. Vessel
litre litre
24x2 100
24x2 100
24x2 100
24x2 100
80 200
80 200

* Maximum pumps flow at minimum set pressure of 2 nd pressure switch.

BS1V1F
Mains: 400V 3~
3~
Motor: 400V 3~
BS1V1F 2MXP 203
BS1V1F 2MXP 204/A
BS1V1F 2MXP 205
BS1V1F 2MXP 403/A
BS1V1F 2MXP 404/A
BS1V1F 2MXP 405

BS2V
Mains: 400V 3~
3~
Motor: 400V 3~
BS2V 2MXP 203
BS2V 2MXP 204/A
BS2V 2MXP 205
BS2V 2MXP 403/A
BS2V 2MXP 404/A
BS2V 2MXP 405

BSM1V1F
Mains: 230V 1~
1~ 230V 3~ and 230V 1~
Motor:
BSM1V1F 2MXP 203
BSM1V1F 2MXP 204/A
BSM1V1F 2MXP 205
BSM1V1F 2MXP 403/A
BSM1V1F 2MXP 404/A
BSM1V1F 2MXP 405

Motor
kW
0,45+0,45
0,55+0,55
0,75+0,75
0,55+0,55
0,75+0,75
1,1+1,1

Manifolds
HP
0,6+0,6
0,75+0,75
1+1
0,75+0,75
1+1
1,5+1,5

DN1
G2
G2
G2
G2
G2
G2

HP
0,6+0,6
0,75+0,75
1+1
0,75+0,75
1+1
1,5+1,5

DN1
G2
G2
G2
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
1100
1100
1100
1100
1100
1100

h1
151
151
151
151
151
151

h2
206
206
206
206
206
206

L1
793
793
793
793
793
793

H
1100
1100
1100
1100
1100
1100

h1
151
151
151
151
151
151

h2
206
206
206
206
206
206

L1
793
793
793
793
793
793

L2
355
355
355
355
355
355

m1

235

Vessel
Weight Membrane
B2
B
litre
kg
24x2
41
24x2
46
24x2
48
625 600
24x2
46
24x2
48
24x2
54

BSM2V
Mains: 230V 1~
1~
Motor:
230V 3~
BSM2V 2MXP 203
BSM2V 2MXP 204/A
BSM2V 2MXP 205
BSM2V 2MXP 403/A
BSM2V 2MXP 404/A
BSM2V 2MXP 405

Motor
kW
0,45+0,45
0,55+0,55
0,75+0,75
0,55+0,55
0,75+0,75
1,1+1,1

Manifolds

563

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
L2
355
355
355
355
355
355

m1

235

Vessel
Weight Membrane
litre
kg
24x2
41
24x2
46
24x2
48
625 600
24x2
46
24x2
48
24x2
54
B2

51

2 NM, NMD

Systems with two Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
U.S. g.p.m. 20

10

U.S. g.p.m.

30

10 Imp. g.p.m.

20

30

Imp. g.p.m. 10

20

36

20

30

44

NMD 20/110B/A

140

NMD 20/110A/A

40
100

30

H
ft

120

30

100

ft

80

m
20

60
16
1

3
50

m 3/h 2
l/min

24
1

6
100

3
50

m 3/h
l/min

6
100

80
9
150

72.955.1C

U.S. g.p.m.

20

30

Imp. g.p.m.

40

20

72.955.2C

U.S. g.p.m. 20

50

30

30

40

10 Imp. g.p.m. 20

40

30

56

35

180

110

NM 2/A/A
30

100

ft

25

NMD 20/140BE

50

160

ft
140

80
40
70

20
1

m 3/h 3
Q l/min
50

6
100

9
150

10

11

36
1

12
200

m 3/h
Q l/min

3
50

6
100

72.955.4C

72.955.3C

U.S. g.p.m. 20

30

U.S. g.p.m.

40

10 Imp. g.p.m. 20

30

20

30

Imp. g.p.m.

40

68

40

20

50

30

40

42

220
3~

120
10

9
150

40

NMD 20/140AE

NM 3/CE

130

200

60

1~

120

35

ft

m
50

m 3/h 3
l/min 50

6
100

9
150

10

ft

160

42
1

H
100

30

140
11

27
1

m 3/h 3
Q l/min 50

6
100

9
150

10

11

72.955.6C

72.955.5C

U.S. g.p.m. 20
Imp. g.p.m.

40

30
20

50

60

40

30

50

U.S. g.p.m. 20

70

Imp. g.p.m.

60

30
20

40

50

30

60

40

50

70
60

60

50
3~

150

NM 3/BE

1~

NM 3/A/A

40

180

50

ft

ft

m
100

30
26
1

90
12
200

m 3/h 4
l/min

6
100

10
150

12
200

14
16
250

140

40
36
1

18
300

m3/h 4

Q l/min

6
100

10
150

12
200

14
16
250

120
18
300

72 955 8C

72 955 7C

564

2 NM, NMD

Systems with two Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Characteristic, dimensions and weights


B

L2
DN 2

H
h2

DN 1

h1
3.93.042

m1
B2

L1

BS2F

BSM2F

Mains: 400V 3~
3~
Motor: 400V 3~

Mains: 230V 1~
1~
Motor: 230V 1~

Motor

kW
HP
BSM2F 2NMDM 20/110B/A 0,45+0,45 0,6+0,6
BSM2F 2NMDM 20/110A/A 0,75+0,75
1+1
BSM2F 2NMM 2/A/A
0,75+0,75
1+1
BSM2F 2NMDM 20/140BE 1,1+1,1 1,5+1,5
BSM2F 2NMDM 20/140AE 1,5+1,5
2+2
BS2F 2NMD 20/140AE
1,5+1,5
2+2
BS2F 2NM 3/CE
BSM2F 2NMM 3/CE
1,1+1,1 1,5+1,5
BSM2F 2NMM 3/BE
1,5+1,5
2+2
BS2F 2NM 3/BE
1,5+1,5
2+2
BS2F 2NM 3/A/A
2,2+2,2
3+3
* Maximum pumps flow at minimum set pressure of 2 nd pressure
BS2F 2NMD 20/110B/A
BS2F 2NMD 20/110A/A
BS2F 2NM 2/A/A
BS2F 2NMD 20/140BE

BS1V1F

Mains: 230V 1~
1~
Motor: 230V 3~ and 230V 1~

BS1V1F 2NMD 20/110B/A


BS1V1F 2NMD 20/110A/A
BS1V1F 2NM 2/A/A
BS1V1F 2NMD 20/140BE

BSM1V1F 2NMD 20/110B/A


BSM1V1F 2NMD 20/110A/A
BSM1V1F 2NM 2/A/A
BSM1V1F 2NMD 20/140BE
BSM1V1F 2NMD 20/140AE
BSM1V1F 2NM 3/CE
BSM1V1F 2NM 3/BE

BS1V1F 2NM 3/BE


BS1V1F 2NM 3/A/A

BS2V

Mains: 230V 1~
1~
Motor: 230V 3~

BS2V 2NMD 20/110B/A


BS2V 2NMD 20/110A/A
BS2V 2NM 2/A/A
BS2V 2NMD 20/140BE

BSM2V 2NMD 20/110B/A


BSM2V 2NMD 20/110A/A
BSM2V 2NM 2/A/A
BSM2V 2NMD 20/140BE
BSM2V 2NMD 20/140AE

BS2V 2NM 3/BE


BS2V 2NM 3/A/A

bar
2,03,0
2,84,0
2,03,0
3,44,9
4,05,3
5,06,3
2,53,5
3,04,0
3,24,5
4,05,3

bar
1,72,7
2,43,6
1,72,7
3,24,7
3,75,0
4,76,0
2,23,2
2,73,7
2,94,2
3,75,0

Manifolds
DN1
G2
G2
G2
G2
G2
G2
G2
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
840
840
840
840
840
840
840
840
840
840

h1
129
129
129
146
146
146
146
146
146
146

h2
277
277
295
295
295
295
325
325
325
325

L1
670
670
620
670
670
670
650
650
650
650

L2
315
315
262
320
320
320
267
267
267
267

m1

B2

235

625

Weight
B
kg
51
55
54
72
600 75
77
71
75
76
78

Vessel
Mem. Vessel
litre litre
24x2 100
60 100
80 200
80 200
100 200
100 200
100 200
100 300
100 300
200 300

Motor
kW
0,45+0,45
0,75+0,75
0,75+0,75
1,1+1,1
1,5+1,5
1,5+1,5
1,1+1,1
1,5+1,5
1,5+1,5
2,2+2,2

Manifolds
HP
0,6+0,6
1+1
1+1
1,5+1,5
2+2
2+2
1,5+1,5
2+2
2+2
3+3

DN1
G2
G2
G2
G2
G2
G2
G2
G2
G2
G2

HP
0,6+0,6
1+1
1+1
1,5+1,5
2+2
2+2
1,5+1,5
2+2
2+2
3+3

DN1
G2
G2
G2
G2
G2
G2
G2
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
840
840
840
840
840
840
840
840
840
840

h1
129
129
129
146
146
146
146
146
146
146

h2
277
277
295
295
295
295
325
325
325
325

L1
670
670
620
670
670
670
650
650
650
650

H
840
840
840
840
840
840
840
840
840
840

h1
129
129
129
146
146
146
146
146
146
146

h2
277
277
295
295
295
295
325
325
325
325

L1
670
670
620
670
670
670
650
650
650
650

L2
315
315
262
320
320
320
267
267
267
267

m1

B2

235

625

m1

B2

235

625

Vessel
Weight Membrane
B
litre
kg
24x2
51
24x2
55
24x2
54
24x2
72
24x2
600 75
24x2
77
24x2
71
24x2
75
24x2
76
24x2
78

BSM2V

Mains: 400V 3~
3~
Motor: 400V 3~

BS2V 2NMD 20/140AE


BS2V 2NM 3/CE

Pres. switch setting

BSM1V1F

Mains: 400V 3~
3~
Motor: 400V 3~

BS1V1F 2NMD 20/140AE


BS1V1F 2NM 3/CE

Q
max*
l/min
120
130
200
160
160
180
200
200
270
280
switch.

BSM2V 2NM 3/CE


BSM2V 2NM 3/BE

Motor
kW
0,45+0,45
0,75+0,75
0,75+0,75
1,1+1,1
1,5+1,5
1,5+1,5
1,1+1,1
1,5+1,5
1,5+1,5
2,2+2,2

Manifolds

565

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
L2
315
315
262
320
320
320
267
267
267
267

Vessel
Weight Membrane
litre
kg
24x2
51
24x2
55
24x2
54
24x2
72
24x2
600 75
24x2
77
24x2
71
24x2
75
24x2
76
24x2
78
B

51

2 NM, NMD

Systems with two Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0 U.S. g.p.m.
46

60

40

0 Imp g.p.m.

100

80
60

40

0 U.S. g.p.m.

120

0 Imp g.p.m.

100

80

100
50

150
100
170

200
180

45

ft

150
ft

140

140

160

30

120
10

15

20

200

300

25
400

160

H
m

0
m3/h 5
Q
l/min
0
100

2NM 25/20A/B

50

2NM 25/20B/B

40

24

50

40

130

38
0
0

28

m3/h
l/min

10

20
200

30

72.956.3C

72.956.1C

0 U.S. g.p.m.

50

0 Imp g.p.m.

100
50

0 U.S. g.p.m.

150
100
200

60

2NM 25/20S/B

36
600

400

66

0 Imp g.p.m.

40

60

20

80

40

60

2NMD 25/190C/A

60

200

180

ft
160

50

180
ft

m
50

160

140
40

140
40
120

120
34

0
0

m /h
l/min

10

20
200

30

36
600

400

34

0
m /h
Q l/min
0

10
100

15

20

200

300
72.956.4C

72.956.3C

0 U.S. g.p.m.
80

40

0 Imp g.p.m. 20

60

0 U.S. g.p.m. 20

80

40

0 Imp g.p.m. 20

60
260

2NMD 25/190B/A

m
70

240

80

60
40

100

60

2NMD 25/190A/A

320

220
ft

90

300
ft
280

200

60

180
50
46

40

80

260
240

160
0
m 3/h
Q l/min
0

10
100

20

15
200

70

300

0
m3/h
Q l/min
0

10
100

20

15
200

300
72.956.6C

72.956.5C

566

2 NM, NMD

Systems with two Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Characteristic, dimensions and weights

L2
DN 2

H
h2

DN 1

h1
3.93.042

m1
B2

L1

BS2F
Mains: 400V 3~
3~
Motor: 400V 3~
BS2F 2NM 25/20B/A
BS2F 2NM 25/20A/A
BS2F 2NM 25/20S/A
BS2F 2NMD 25/190C/A
BS2F 2NMD 25/190B/A
BS2F 2NMD 25/190A/A
* Maximum pumps flow at

Q
Pres. switch setting
max*
kW
HP
l/min
bar
bar
2,2+2,2
3+3
400
3,04,0
2,73,7
3+3
4+4
440
3,84,8
3,54,5
4+4
5,5+5,5
560
4,05,5
3,55,0
2,2+2,2
3+3
280
4,35,8
3,85,3
3+3
4+4
300
5,07,0
4,56,5
4+4
5,5+5,5
320
7,59,0
7,08,5
minimum set pressure of 2 nd pressure switch.
Motor

Manifolds
DN1
G 21/2
G 21/2
G 21/2
G 21/2
G 21/2
G 21/2

DN2
G2
G2
G2
G2
G2
G2

mm
H
840
840
840
840
840
840

h1
160
160
160
175
175
175

h2
330
330
330
330
330
330

L1
725
725
725
760
760
760

H
840
840
840
840
840
840

h1
160
160
160
175
175
175

h2
330
330
330
330
330
330

L1
725
725
725
760
760
760

L2
373
373
373
407
407
407

m1

B2

235

625

m1

B2

235

625

Weight
B
kg
87
106
114
600 108
123
132

Vessel
Mem. Vessel
litre litre
300 500
500 800
500 800
200 300
200 300
300 500

BS1V1F
Mains: 400V 3~
3~
Motor: 400V 3~
BS1V1F 2NM 25/20B/A
BS1V1F 2NM 25/20A/A
BS1V1F 2NM 25/20S/A
BS1V1F 2NMD 25/190C/A
BS1V1F 2NMD 25/190B/A
BS1V1F 2NMD 25/190A/A

Motor
kW
2,2+2,2
3+3
4+4
2,2+2,2
3+3
4+4

Manifolds

HP
3+3
4+4
5,5+5,5
3+3
4+4
5,5+5,5

DN1
G 21/2
G 21/2
G 21/2
G 21/2
G 21/2
G 21/2

DN2
G2
G2
G2
G2
G2
G2

mm
L2
373
373
373
407
407
407

Vessel
Weight Membrane
litre
kg
24x2
87
24x2
106
24x2
114
600 108
24x2
24x2
123
24x2
132
B

BS2V
Mains: 400V 3~
3~
Motor:
400V 3~
BS2F 2NM 25/20B/A
BS2F 2NM 25/20A/A
BS2F 2NM 25/20S/A
BS2F 2NMD 25/190C/A
BS2F 2NMD 25/190B/A
BS2F 2NMD 25/190A/A

Motor
kW
2,2+2,2
3+3
4+4
2,2+2,2
3+3
4+4

Manifolds

HP
3+3
4+4
5,5+5,5
3+3
4+4
5,5+5,5

DN1
G 21/2
G 21/2
G 21/2
G 21/2
G 21/2
G 21/2

567

DN2
G2
G2
G2
G2
G2
G2

mm
H
840
840
840
840
840
840

h1
160
160
160
175
175
175

h2
330
330
330
330
330
330

L1
725
725
725
760
760
760

L2
373
373
373
407
407
407

m1

B2

235

625

Vessel
Weight Membrane
litre
B
kg
24x2
87
24x2
106
24x2
114
600 108
24x2
24x2
123
24x2
132

51

2 NGL, NG

Systems with two self-priming Jet pumps


Fixed speed pump

Coverage chart
0

U.S. g.p.m.

10

Imp. g.p.m.

U.S. g.p.m. 10

Imp. g.p.m.

20
10

50
H
m
40

NGL 2

30

10

20

50
H
m
40

150

30

20

NGL 3/A

150

ft

ft

100

100

30

20

20

50

50
10
3
0
/h 1
Q m
l/min 20
0

60

40

10

80

0 m3/h
Q
0 l/min 20

5
80

60

40

6
100

72.1146.2

72.1146.1

0 U.S. g.p.m.

20

30

0 Imp. g.p.m. 10

0 U.S. g.p.m.

40

20

10

15

0 Imp. g.p.m.

30

50
H
m
40

25

20

10

20

15

60

NGL 4/A

150

NG 3/A

m
ft

150
40

100

30

H
ft
100

20
50
10

m3/h 2
0
Q
l/min
0

6
100

4
50

20

10
150

0 m3 /h 1
Q
0 l/min 20

40

6
100

5
80

60

72.1146.3

0 U.S. g.p.m. 10
0 Imp. g.p.m.

20
10

72.954.3C

0 U.S. g.p.m.

30

20

30

0 Imp. g.p.m. 10

20

40

20

30

70

50
150

NG 4/A

200

NG 5/16E

ft
100

30

ft

50

150
40

15

0
m3 /h
Q l/min
0

4
40

80

50

30

120

0 m3 /h 2
Q
0 l/min

6
100

50

150
72.954.5C

72.954.4C

0 U.S. g.p.m.

30

0 Imp. g.p.m. 20

40

50

30

40

60

70

50

0 U.S. g.p.m.

80

60

30

0 Imp. g.p.m. 20

70

60

40
30

50
40

60

70

50

80

60

70

60

NG 6/22E

m
40

150

50

3
1
0
m3 /h
0 Q l/min

5
100

10

100

15
200

150

40

3
1

30

NG 7/22/A

ft

20

100
10

ft
30

20
300
72.954.6C

0
m3 /h
0 Q l/min

5
100

10

100
20

15
200

300
72.954.7C

568

2 NGL, NG

Systems with two self-priming Jet pumps


Fixed speed pump

Characteristic, dimensions and weights


B

L2

DN 2

H
DN 1

h2

h1
3.93.044

m1
B2

L1

BS2F

BSM2F

Mains: 400V 3~
3~
Motor: 400V 3~

Mains: 230V 1~
Motor: 230V 1~

BS2F 2NGL 2
BS2F 2NGL 3/A
BS2F 2NGL 4/A

BSM2F 2NGLM 2
BSM2F 2NGLM 3/A
BSM2F 2NGLM 4/A

Motor
kW
HP
0,45+0,45 0,6+0,6
0,55+0,55 0,75+0,75
0,75+0,75
1+1

Q
max*
l/min
70
90
160

Pres. switch setting


bar
2,43,6
2,84,0
2,23,4

bar
2,03,2
2,43,6
1,83,0

Manifolds
DN1
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2

mm
H
840
840
840

h1
151
151
151

h2
206
206
206

L1
793
793
793

L2
355
355
355

m1
235

Weight
kg
42
625 600 46
49

Vessel
Mem. Vessel
litre litre
24x2 100
24x2 100
24x2 100

Weight
B
kg
61
62
600 86
89
90
92

Vessel
Mem. Vessel
litre litre
24x2 100
24x2 100
24x2 100
100 200
100 200
200 300

B2

* Maximum pumps flow at minimum set pressure of 2 nd pressure switch.

BS2F
Mains: 400V 3~
3~
Motor: 400V 3~
BS2F 2NG 3/A
BS2F 2NG 4/A
BS2F 2NG 5-16E
BS2F 2NG 6-22E
BS2F 2NG 7-22/A

BSM2F
Mains: 230V 1~
1~
Motor: 230V 1~

Motor

kW
HP
BSM2F 2NGM 3/A
0,55+0,55 0,75+0,75
BSM2F 2NGM 4/A
0,75+0,75
1+1
BSM2F 2NGM 5-16E 1,1+1,1
1,5+1,5
2+2
BSM2F 2NGM 6-22E 1,5+1,5
1,5+1,5
2+2
2,2+2,2
3+3

Q
max*
l/min
95
130
140
290
290
300

Pres. switch setting


bar
3,04,2
2,43,6
3,85,3
3,04,2
3,24,5
3,85,3

bar
2,53,7
2,03,2
3,44,9
2,53,7
2,84,0
3,44,9

Manifolds
DN1
G2
G2
G 21/2
G 21/2
G 21/2
G 21/2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
840
840
840
840
840
840

h1
184
184
200
200
200
200

h2
188
188
202
202
202
202

L1
775
775
935
935
935
935

L2
345
345
470
470
470
470

m1

B2

235

625

* Maximum pumps flow at minimum set pressure of 2 nd pressure switch.

51

569

2 NGX

Systems with two self-priming Jet pumps


Fixed speed pump

Coverage chart

U.S. g.p.m.

Imp. g.p.m.

10

U.S. g.p.m. 10

Imp. g.p.m.

20
10

50
H
m
40

NGX 2

150

20

30

10

20

50
H
m
40

NGX 3

150
ft

ft
100

30

100

30

20

20

50

50
10
3
0
/h 1
Q m
l/min 20
0

40

10

60

80

0 m3/h
Q
0 l/min 20

60

40

72.1146.2

72.1146.1

0 U.S. g.p.m.

20

0 Imp. g.p.m. 10

30
20

6
100

5
80

40
30

50
H
m
40

NGX 4

150
ft
100

30

20
50
10

m3/h 2
0
Q
l/min
0

6
100

4
50

10
150
72.1146.3

0 U.S. g.p.m.

20

0 Imp. g.p.m. 10

30
20

0 U.S. g.p.m.

40

30

0 Imp. g.p.m. 20

30

60

40
30

50
40

60

70

50

80

60

70

60

NGX 5/16

NGX 6/22

m
150

40

150

40

ft
100

30
20

ft

0
m3 /h 2
0 Q l/min

4
50

6
100

20

10
150
72.1146.4

100

30

0
m3 /h
0 Q l/min

5
100

10

15
200

20
300
72.1146.5

570

2 NGX

Systems with two self-priming Jet pumps


Fixed speed pump

Characteristic, dimensions and weights


B

L2
DN 2
H
DN 1

h2

h1
4.93.315

m1
L1

BS2F
Mains: 400V 3~
3~
Motor: 400V 3~
BS2F 2NGX 2
BS2F 2NGX 3/A
BS2F 2NGX 4/A
BS2F 2NGX 5-16
BS2F 2NGX 6-22

B2

BSM2F
Mains: 230V 1~
Motor: 230V 1~

Motor

kW
HP
BSM2F 2NGXM 2
0,45+0,45 0,6+0,6
BSM2F 2NGXM 3/A 0,55+0,55 0,75+0,75
BSM2F 2NGXM 4/A 0,75+0,75
1+1
BSM2F 2NGXM 5-16 1,1+1,1
1,5+1,5
2+2
BSM2F 2NGXM 6-22 1,5+1,5

Q
max*
l/min
70
90
160
140
280

Pres. switch setting


bar
2,43,6
2,84,0
2,23,4
3,44,9
3,04,2

bar
2,03,2
2,43,6
1,83,0
3,04,5
2,53,7

Manifolds
DN1
G2
G2
G2
G2
G2

DN2
G 11/2
G 11/2
G 11/2
G 11/2
G 11/2

mm
H
840
840
840
840
840

h1
151
151
151
187
187

h2
206
206
206
212
212

L1
793
793
793
836
836

L2
355
355
355
380
380

m1

235

Weight
B2
B
kg
42
46
625 600 49
61
65

Vessel
Mem. Vessel
litre litre
24x2 100
24x2 100
24x2 100
24x2 100
100 200

* Maximum pumps flow at minimum set pressure of 2 nd pressure switch.

51

571

BS. MXH

Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
10 U.S. g.p.m. 30 40 50
10 Imp. g.p.m.

30 40 50

100
100

200

300 400 500

150 200

800

300 400 500 700

70

200

60

H
ft
50
150
40

1-3MXH

H
m

100

30

20
50
10

0
2

m3/h

Q l/min

5
100

10
15 20
30 40 50
1000
150 200 300 400 500

100 150 200


2000 3000
72.949.C

Operation
BS 1-6F

Electrical control boards:


- with microprocessor for fixed speed pump units (see page 486). Motor
starting is D.O.L. up to 5,5 kW and Y/ for power rating 7,5 kW.
- with frequency converter for variable speed pump units (see page 487).

Pressure boosting sets with 1 to 6 fixed speed pump.


Sets with 4,5 and 6 pumps on request.
Depending on the reduction of the pressure in the system,
the pressure switches determine the starting up of the pumps
in sequence and the microprocessor alternates the starts.

The unit includes one pressure gauge and three adjustable differential
pressure switches or pressure transducer (for sets with frequency converter).

BS1V2-5F Pressure boosting sets with 1 variable speed pump (with


frequency converter into the control panel) and from 1 to 5
fixed speed pumps
Sets with 4,5 and 6 pumps on request.
According to the water consumption, one or more pumps
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure.
BS1-6V

Applications
To supply water in civil and industrial buildings.
As pressure boosting pump to increase water pressure when needed
(follow local rules).

Pressure boosting sets with 1 to 6 variable speed pumps


(with frequency converter into the control panel).
Sets with 4,5 and 6 pumps on request.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.

Motors
2-pole induction motors, 50 Hz, n 2900 rpm, suitable for operation with
frequency converter.
- Three-phase 230/400V 10% up to 3 kW;
400/690V 10% for 4 kW to 7,5 kW;
- Single-phase 230 V 10%, with thermal protector.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.

Construction
- Automatic pressure boosting plant consisting of 1 horizontal multi-stage
close coupled pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.

Vessels on request
- Automatic pressure boosting plant consisting of 2 to 6 horizontal multistage pumps complete with ball, non return valve on the suction side
and ball valves on the delivery side.
Suction and delivery manifolds are in AISI 304.
Connections are located on the delivery manifold for the installation of
20 litres cylindrical vessels:
- 2 vessels for 2-pump sets.
- 3 vessels for 3-pump sets.

When installing the unit, connect in the delivery section to a diaphragm


or galvanised tank.
The recommended sized are shown in the following page.

Special features on request


Pressure boosting sets with 4,5 and 6 pumps.

572

BS. MXH

Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0

Imp. g.p.m.

15

30

45

30

Imp. g.p.m.

60

70

70

1-3MXH 2

60

200

1-3MXH 4

60

200

50

50

150

m
40

ft

ft

30

100

100

30

4
20

150

m
40

20

50

50
10

10

0
0
0

m3/h
Q l/min

0
3
60

12

6
120

Imp g.p.m.

180

50

0
0

15
240

100

150

12

100

200

70

40

30

50

150

40

100

ft

30

100

3
20

50

50

10

0
0
0

20

200

ft

280

60

150

1-3MXH 16

1-3MXH 8

50

24

18
300

150

0 Imp g.p.m.

200

60

m3/h

Q l/min

10

10
200

l/min

20
300

0 U.S. g.p.m. 75

150

40

30
500

400

600

700

300

225

ft

200

60

40

40

200

Imp. g.p.m.

50
800

600

60
1000

300

70
1200

400

80

500
ft

1-3MXH 32

60

5
H
m

30
400

70

1-3MXH 20

70

20

80

90
80

0
0 Q m 3/h
0
l/min

0
3
Q m /h

H
m

200

40

30

100

30

100

2
20

20

10

10
0

0
0
0

3
Q m /h
l/min

20
300

30

40
600

50

60
900

0
m 3/h
Q l/min
0

70 75
1200

50
500

0 Imp. g.p.m.

1000

200

0
150
2500

100

300

1500
400

2000

500

600

700

70
200

60

1-3MXH 48

H
m

ft

40

3
100

30

2
20
10
0
0 m3/h 30
Q
0 l/min 500

573

60
1000

90
1500

120
2000

150
2500

180
3000

0
210
3500

51

BS. MXH

Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS1F
Mains: 400V 3~
Motor: 400V 3~
BS1F 1MXH 203E
BS1F 1MXH 204/A
BS1F 1MXH 205/A
BS1F 1MXH 206/B
BS1F 1MXH 403/A
BS1F 1MXH 404/A
BS1F 1MXH 405/B
BS1F 1MXH 406
BS1F 1MXH 803
BS1F 1MXH 804
BS1F 1MXH 805/A
BS1F 1MXH 1603/A
BS1F 1MXH 1604/A
BS1F 1MXH 1605/A
BS1F 1MXH 1606/A
BS1F 1MXH 2002
BS1F 1MXH 2003
BS1F 1MXH 2004
BS1F 1MXH 2005
BS1F 1MXH 3202/A
BS1F 1MXH 3203/A
BS1F 1MXH 3204/A
BS1F 1MXH 4802/A
BS1F 1MXH 4803/A

BSM1F
Mains: 230V 1~
Motor: 230V 1~

Pres. switch 1
bar

Motor
kW
0,45
0,55
0,75
1,1
0,55
0,75
1,1
1,5
1,1
1,5
1,8
1,8
3
3,7
4
2,2
3
4
5,5
4
5,5
7,5
5,5
7,5

BSM1F 1MXHM 203E


BSM1F 1MXHM 204/A
BSM1F 1MXHM 205/A
BSM1F 1MXHM 206
BSM1F 1MXHM 403/A
BSM1F 1MXHM 404/A
BSM1F 1MXHM 405
BSM1F 1MXHM 406
BSM1F 1MXHM 803
BSM1F 1MXHM 804

HP
0,6
0,75
1
1,5
0,75
1
1,5
2
1,5
2
2,5
2,5
4
5
5,5
3
4
5,5
7,5
5,5
7,5
10
7,5
10

min
1,4
2,8
3,5
4
1,4
2,4
3,4
4
1,6
2,8
3,5
1,5
2,8
3,8
4,5
1,5
3
4,4
5,5
1,5
3
4
1,5
3

max
2,8
4
5
6
2,6
3,6
4,9
6
2,8
4
5
3
4
5,3
6,5
2,8
4,5
5,9
7
3
4,5
6
3
4,5

Maximum capacity *
Hm

Vessel
Membrane
litre

Vessel

Q l/min
70
55
56
61
122
107
102
111
209
186
186
382
353
331
329
399
367
348
343
770
682
725
975
886

14
29
36
41
14
24
35
41
16
29
36
15
29
39
46
15
31
45
56
15
31
41
15
31

24
40
50
50
60
80
100
100
100
200
200
300
500
500
500
300
500
1000
1000
1000
1000
1500
1500
2000

100
100
100
100
100
200
200
200
300
300
500
500
1000
1000
800
500
1000
1500
1500
2000
2000
3000
2000
3000

litre

* Maximum pumps flow at minimum setting pressure switch.

BS2F
Mains: 400V 3~
Motor: 400V 3~
BS2F 2MXH 203E
BS2F 2MXH 204/A
BS2F 2MXH 205/A
BS2F 2MXH 206/B
BS2F 2MXH 403/A
BS2F 2MXH 404/A
BS2F 2MXH 405/B
BS2F 2MXH 406E
BS2F 2MXH 803
BS2F 2MXH 804
BS2F 2MXH 805/A
BS2F 2MXH 1603/A
BS2F 2MXH 1604/A
BS2F 2MXH 1605/A
BS2F 2MXH 1606/A
BS2F 2MXH 2002
BS2F 2MXH 2003
BS2F 2MXH 2004
BS2F 2MXH 2005
BS2F 2MXH 3202/A
BS2F 2MXH 3203/A
BS2F 2MXH 3204/A
BS2F 2MXH 4802/A
BS2F 2MXH 4803/A

BSM2F
Alimentazione 230V 1~
Motore 230V 1~
BSM2F 2MXHM 203E
BSM2F 2MXHM 204/A
BSM2F 2MXHM 205/A
BSM2F 2MXHM 206
BSM2F 2MXHM 403/A
BSM2F 2MXHM 404/A
BSM2F 2MXHM 405
BSM2F 2MXHM 406
BSM2F 2MXHM 803
BSM2F 2MXHM 804

Motor
kW
0,45 x2
0,55 x2
0,75 x2
1,1 x2
0,55 x2
0,75 x2
1,1 x2
1,5 x2
1,1 x2
1,5 x2
1,8 x2
1,8 x2
3 x2
3,7 x2
4 x2
2,2 x2
3 x2
4 x2
5,5 x2
4 x2
5,5 x2
7,5 x2
5,5 x2
7,5 x2

HP
0,6 x2
0,75 x2
1 x2
1,5 x2
0,75 x2
1 x2
1,5 x2
2 x2
1,5 x2
2 x2
2,5 x2
2,5 x2
4 x2
5 x2
5,5 x2
3 x2
4 x2
5,5 x2
7,5 x2
5,5 x2
7,5 x2
10 x2
7,5 x2
10 x2

Pres. switch 1
bar

min
1,4
2,8
3,5
4
1,4
2,4
3,4
4
1,6
2,8
3,5
1,5
2,8
3,8
4,5
1,5
3
4,4
5,5
1,5
3
4
1,5
3

max
2,8
4
5
6
2,6
3,6
4,9
6
2,8
4
5
3
4
5,3
6,5
2,8
4,5
5,9
7
3
4,5
6
3
4,5

Pres. switch 2
bar

min
1
2,4
3
3,5
1
2
3
3,5
1,2
2,4
3
1,2
2,4
3,4
4
1,2
2,5
3,9
5,1
1,2
2,5
3,5
1,2
2,5

max
2,4
3,6
4,5
5,5
2,2
3,2
4,5
5,5
2,4
3,6
4,5
2,7
3,6
4,9
6
2,5
4
5,4
6,6
2,7
4
5,5
2,7
4

Maximum capacity *
Hm

Vessel
Membrane
litre

Vessel

Q l/min
156
128
130
136
264
237
224
241
442
406
405
805
770
728
725
797
785
752
725
1615
1498
1549
2064
1946

10
24
31
36
10
20
31
36
12
24
31
12
24
35
41
12
25
40
52
12
25
36
12
25

24
40
50
50
60
80
100
100
100
200
200
300
500
500
500
300
500
1000
1000
1000
1000
1500
1500
2000

100
100
100
100
100
200
200
200
300
300
500
500
1000
1000
800
500
1000
1500
1500
2000
2000
3000
2000
3000

* Maximum pumps flow at minimum setting pressure of 2 nd pressure switch.

BS3F
Mains: 400V 3~
Motor: 400V 3~
BS3F 3MXH 203E
BS3F 3MXH 204/A
BS3F 3MXH 205/A
BS3F 3MXH 206/B
BS3F 3MXH 403/A
BS3F 3MXH 404/A
BS3F 3MXH 405/B
BS3F 3MXH 406E
BS3F 3MXH 803
BS3F 3MXH 804
BS3F 3MXH 805/A
BS3F 3MXH 1603/A
BS3F 3MXH 1604/A
BS3F 3MXH 1605/A
BS3F 3MXH 1606/A
BS3F 3MXH 2003
BS3F 3MXH 2004
BS3F 3MXH 2005
BS3F 3MXH 3202/A
BS3F 3MXH 3203/A
BS3F 3MXH 3204/A
BS3F 3MXH 4802/A
BS3F 3MXH 4803/A

Motor
kW
0,45 x3
0,55 x3
0,75 x3
1,1 x3
0,55 x3
0,75 x3
1,1 x3
1,5 x3
1,1 x3
1,5 x3
1,8 x3
1,8 x3
3 x3
3,7 x3
4 x3
3 x3
4 x3
5,5 x3
4 x3
5,5 x3
7,5 x3
5,5 x3
7,5 x3

HP
0,6 x3
0,75 x3
1 x3
1,5 x3
0,75 x3
1 x3
1,5 x3
2 x3
1,5 x3
2 x3
2,5 x3
2,5 x3
4 x3
5 x3
5,5 x3
4 x3
5,5 x3
7,5 x3
5,5 x3
7,5 x3
10 x3
7,5 x3
10 x3

Pres. switch 1
bar
min
1,4
2,8
3,5
4
1,4
2,4
3,4
4
1,8
2,8
3,5
1,5
2,8
3,8
4,5
3
4,4
5,5
1,5
3
4
1,5
3

max
2,8
4
5
6
2,6
3,6
4,9
6
2,8
4
5
3
4
5,3
6,5
4,5
5,9
7
3
4,5
6
3
4,5

Pres. switch 2
bar
min
1
2,4
3
3,5
1
2
3
3,5
1,4
2,4
3
1,2
2,4
3,4
4
2,5
3,9
5,1
1,2
2,5
3,5
1,2
2,5

max
2,4
3,6
4,5
5,5
2,2
3,2
4,5
5,5
2,4
3,6
4,5
2,7
3,6
4,9
6
4
5,4
6,6
2,7
4
5,5
2,7
4

* Maximum pumps flow at minimum setting pressure of 3 nd pressure switch.

574

Pres. switch 3
bar
min
0,6
2
2,5
3
0,6
1,6
2,6
3
1
2
2,5
0,9
2
3
3,5
2
3,4
4,7
0,9
2
3
0,9
2

max
2
3,2
4
5
1,8
2,8
4,1
5
2
3,2
4
2,4
3,2
4,5
5,5
3,5
4,9
6,2
2,4
3,5
5
2,4
3,5

Maximum capacity *
Q l/min
253
215
217
223
413
382
361
383
676
645
643
1247
1217
1165
1166
1201
1181
1134
2486
2389
2429
3237
3140

Hm
6
20
25
31
6
16
27
31
10
20
25
9
20
31
36
20
35
47
9
20
31
9
20

Vessel
Membrane
litre

Vessel

24
40
50
50
60
80
100
100
100
200
200
300
500
500
500
500
1000
1000
1000
1000
1500
1500
2000

100
100
100
100
100
200
200
200
300
300
500
500
1000
1000
800
1000
1500
1500
2000
2000
3000
2000
3000

litre

litre

BS. MXH

Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS..
PUMPS
Nos
N.
POMPE
1

BS1V

BS2V
BS3V
BS1V1F
BS1V2F
BSM1V1F*
BSM2V**

PUMP TYPE
TIPO POMPE

BS4V
BS1V3F

BS5V
BS1V4F

(*) SYSTEMS WITH:


1 variable speed pump three-phase motor
1 fixed speed pump single-phase motor
Power supply to control panel 230 V single-phase

BS6V
BS1V5F

MXH 203E
MXH 204/A
MXH 205/A
MXH 206/B
MXH 403/A
MXH 404/A
MXH 405/B
MXH 406E
MXH 803
MXH 804
MXH 805/A
MXH 1603/A
MXH 1604/A
MXH 1605/A
MXH 1606/A
MXH 2002
MXH 2003
MXH 2004
MXH 2005
MXH 3202/A
MXH 3203/A
MXH 3204/A
MXH 4802/A
MXH 4803/A

PP22
ForPer
each
pump
pompa
kW
0,45
0,55
0,75
1,1
0,55
0,75
1,1
1,5
1,1
1,5
1,8
1,8
3
3,7
4
2,2
3
4
5,5
4
5,5
7,5
5,5
7,5

HP
0,6
0,75
1
1,5
0,75
1
1,5
2
1,5
2
2,5
2,5
4
5
5,5
3
4
5,5
7,5
5,5
7,5
10
7,5
10

(**) Three-phase motor 230 V.


Power supply to control panel: - 230 V three-phase
- 230 V single-phase
Frequency converter output is alwais 230 V three-phase.

51

575

BS. MXH

Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

Hv
Hf
DN2

h2
DN1

h1

m1

B2

Connection
Collettori

TYPE
BS.. 1MXH 203E
BS.. 1MXH 204/A
BS.. 1MXH 205/A
BS.. 1MXH 206/B
BS.. 1MXH 403/A
BS.. 1MXH 404/A
BS.. 1MXH 405/B
BS.. 1MXH 406E
BS.. 1MXH 803
BS.. 1MXH 804
BS.. 1MXH 805/A
BS.. 1MXH 1603/A
BS.. 1MXH 1604/A
BS.. 1MXH 1605/A
BS.. 1MXH 1606/A
Dimensions not binding to

mm

DN 1

DN 2

Hv

Hf

h1

h2

m1

B2

G 1 1/4

G1

1045

875

170

145

625

365

G 1 1/4

G1

1045

875

170

145

625

365

G 1 1/2

G1

1045

875

170

145

625

365

1045

875

175

195

625

365

G 1 1/2 G 1 1/2

be verified when ordering

DN 2

h2

weight
Peso
kg
-

Hv
Hf

DN 1

h1

m1

TYPE
BS..
BS..
BS..
BS..
BS..
BS..
BS..
BS..
BS..

1MXH 2002
1MXH 2003
1MXH 2004
1MXH 2005
1MXH 3202/A
1MXH 3203/A
1MXH 3204/A
1MXH 4802/A
1MXH 4803/A

B2

Connection
Collettori

weight
Peso

mm

DN 1

DN 2

Hv

Hf

h1

h2

m1

B2

G2

G 1 1/2

1045

875

195

197

625

365

1145

1145

65

50

1045

875

195

265

625

365

80

65

1145

1145

195

275

625

365

Dimensions not binding to be verified when ordering

576

kg

BS. MXH

Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights


BS.. 2MXH 2,4,8

BS.. 2MXH 16
B

L2
DN 2

L2

DN 2
H
h2

DN 1

DN 1

h1

h2

h1

3.93.159

3.93.043

m1

m1

L1

B2

Connection
Collettori
H
DN 1
DN 2
BS.. 2MXH
203E
G2
G 11/2 840
TYPE
BS.. 2MXH 204/A
G2
G 11/2 840
BS.. 2MXH 205/A
G2
G 11/2 840
BS.. 2MXH 206/B
G2
G 11/2 840
BS.. 2MXH 403/A
G2
G 11/2 840
BS.. 2MXH 404/A
G2
G 11/2 840
BS.. 2MXH 405/B
G2
G 11/2 840
BS.. 2MXH 406E
G2
G 11/2 840
BS.. 2MXH 803
G 21/2
G2
840
BS.. 2MXH 804
G 21/2
G2
840
BS.. 2MXH 805/A
G 21/2
G2
840
BS.. 2MXH 1603/A
G3
G 21/2 985
BS.. 2MXH 1604/A
G3
G 21/2 985
BS.. 2MXH 1605/A
G3
G 21/2 985
BS.. 2MXH 1606/A
G3
G 21/2 985
Dimensions not binding to be verified when ordering

B2

L1

mm
h1
162
162
162
162
162
162
162
162
162
162
162
250
265
265
265

h2
202
202
202
202
202
202
202
202
208
208
208
295
295
295
295

L1
773
796
820
845
773
796
820
845
866
896
926
945
1045
1085
1120

L2
335
358
382
406
335
358
382
406
428
458
488
490
530
565
605

m1

B2

235

625

600

625

600

905
1040

weight
Peso
kg
42
47
50
54
46
49
53
57
61
66
68
87
114
122
124

B
DN 2

L2

h1

h2

DN 1

3.93.155

m1

B2

L1

TYPE

Connection
Collettori

H
DN 1
DN 2
BS.. 2MXH 2002
G3
G 2 1/2 1510
BS.. 2MXH 2003
G3
G 2 1/2 1510
BS.. 2MXH 2004
G3
G 2 1/2 1510
BS.. 2MXH 2005
G3
G 2 1/2 1510
BS.. 2MXH 3202/A
100
80
1510
BS.. 2MXH 3203/A
100
80
1510
BS.. 2MXH 3204/A
100
80
1510
BS.. 2MXH 4802/A
125
100
1510
BS.. 2MXH 4803/A
125
100
1510
Dimensions not binding to be verified when ordering

weight
Peso

mm
h1
215
225
225
247
285
285
285
285
285

h2
391
391
391
391
435
435
435
465
465

577

L1
977
1013
1048
1091
1265
1270
1320
1380
1420

L2
499
518
553
587
565
615
660
665
725

m1
810
810
810
995
1175
1175
1175
1175
1220

B2

kg

51
800

750

214
243
260
268
286

BS. MXH

Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights


BS.. 3MXH 2,4,8

BS.. 3MXH 16

L2
DN 2

L2

DN 2
DN 1

h2

H
DN 1

h1

h2

h1

3.93.159

m1

3.93.043

m1
L1

Connection
Collettori

TYPE

H
DN 1
DN 2
BS.. 3MXH 203E
G2
G 2 1/2
840
G 2 1/2
BS.. 3MXH 204/A
G2
840
G 2 1/2
BS.. 3MXH 205/A
G2
840
G 2 1/2
BS.. 3MXH 206/B
G2
840
G 2 1/2
BS.. 3MXH 403/A
G2
840
G 2 1/2
BS.. 3MXH 404/A
G2
840
G 2 1/2
BS.. 3MXH 405/B
G2
840
G 2 1/2
BS.. 3MXH 406E
G2
840
G3
BS.. 3MXH 803
G 21/2 840
G3
BS.. 3MXH 804
G 21/2 840
G3
BS.. 3MXH 805/A
G 21/2 840
DN 100 DN 80
BS.. 3MXH 1603/A
985
DN 100 DN 80
BS.. 3MXH 1604/A
985
DN 100 DN 80
BS.. 3MXH 1605/A
985
DN 100 DN 80
BS.. 3MXH 1606/A
985
Dimensions not binding to be verified when ordering

B2

L1

B2

mm
h1
162
162
162
162
162
162
162
162
162
162
162
250
265
265
265

h2
202
202
202
202
202
202
202
202
208
208
208
295
295
295
295

L1
773
796
820
845
773
796
820
845
866
896
926
945
1045
1085
1120

L2
335
358
382
406
335
358
382
406
428
458
488
490
530
565
605

m1

B2

235

1350 1200

weight
Peso
kg
-

905
1040

1350 1200

B
DN 2

L2

h1

h2

DN 1

3.93.155

m1

B2

L1

TYPE

Connection
Collettori

H
DN 1
DN 2
BS.. 3MXH 2002
100
80
1510
BS.. 3MXH 2003
100
80
1510
BS.. 3MXH 2004
100
80
1510
BS.. 3MXH 2005
100
80
1510
BS.. 3MXH 3202/A
125
100
1510
BS.. 3MXH 3203/A
125
100
1510
BS.. 3MXH 3204/A
125
100
1510
BS.. 3MXH 4802/A
150
125
1510
BS.. 3MXH 4803/A
150
125
1510
Dimensions not binding to be verified when ordering

weight
Peso

mm
h1
225
225
225
247
285
285
285
285
285

578

h2
391
391
391
391
435
435
435
465
465

L1
1021
1037
1092
1135
1265
1270
1320
1380
1420

L2
499
518
553
597
565
615
660
665
725

m1
810
810
810
995
1175
1175
1175
1175
1220

B2

1250 1200

kg
-

BS. MXSU

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0 U.S. g.p.m.

100

50

0 Imp g.p.m.

50

150
100

70
200

60

50

150

m
40

ft
100

30

1-3MXSU

20

50
10

0
m 3/h 6
0 Q l/min

12
200

18
300

24
400

30
500

0
36
600
72.923

Operation
BS 1-6F

Electrical control boards:


- with microprocessor for fixed speed pump units (see page 486).
- with frequency converter for variable speed pump units (see page
487).

Pressure boosting sets with 1 to 6 fixed speed pump.


Sets with 4,5 and 6 pumps on request.
Depending on the reduction of the pressure in the system,
the pressure switches determine the starting up of the pumps
in sequence and the microprocessor alternates the starts.

The unit includes one pressure gauge and three adjustable differential
pressure switches or pressure transducer (for sets with frequency converter).

BS1V2-5F Pressure boosting sets with 1 variable speed pump (with


frequency converter into the control panel) and from 1 to 5
fixed speed pumps
Sets with 4,5 and 6 pumps on request.
According to the water consumption, one or more pumps
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure.
BS1-6V

Applications
To supply water in civil and industrial buildings.
As pressure boosting pump to increase water pressure when needed
(follow local rules).

Pressure boosting sets with 1 to 6 variable speed pumps


(with frequency converter into the control panel).
Sets with 4,5 and 6 pumps on request.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.

Motors
2-pole induction motors, 50 Hz, n 2900 rpm, suitable for operation with
frequency converter.
- Three-phase 230V - 400V 10%;
- Single-phase 230 V 10%.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.

Construction
- Automatic pressure boosting plant consisting of 1 vertical multi-stage
close coupled pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.

Vessels on request
When installing the unit, connect in the delivery section to a diaphragm
or galvanised tank.
The recommended sized are shown in the following page.

- Automatic pressure boosting plant consisting of 2 to 6 vertical multistage close coupled pumps complete with ball, non return valve on the
suction side and ball valves on the delivery side.
Suction and delivery manifolds are in AISI 304.
Connections are located on the delivery manifold for the installation of
20 litres cylindrical vessels:
- 2 vessels for 2-pump sets.
- 3 vessels for 3-pump sets.

Special features on request


Pressure boosting sets with 4,5 and 6 pumps.

579

51

BS. MXSU

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0 Imp g.p.m.10

20

30

40

0 Imp g.p.m.20

50

40

60

80

60

70

m
60

1-3MXSU 2

200

ft

1-3MXSU 4

50
ft

150

50
206

40

40

150

405

205

30

100

404

30

204

100
20

20

50

50
10

0 m3/h 2
Q
0 l/min 40

6
80

10
160

120

12
200

10

14
72.945.1C

0 Imp g.p.m.
20

40

60

80

100

120
150

1-3MXSU 8

40

ft
804

100

30
803

20
50
10

0 m3 /h
8
Q
0 l/min 100

12
200

16

20
300

24
400

28

32 34

8
100

12
200

16

20
300

24 26
400
72.945.2C

50

0 m3/h 4
Q
0 l/min

500
72.945.3C

580

BS. MXSU

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS1F

BSM1F

Mains: 400V 3~
Motor: 400V 3~
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F

1MXSU
1MXSU
1MXSU
1MXSU
1MXSU
1MXSU
1MXSU

Mains: 230V 1~
Motor: 230V 1~

204/A
205/A
206/A
404/A
405/A
803/A
804/A

BSM1F
BSM1F
BSM1F
BSM1F
BSM1F
BSM1F

Pres. switch 1
bar

Motor

1MXSU
1MXSU
1MXSU
1MXSU
1MXSU
1MXSU

kW
0,55
0,75
0,9
0,9
1,1
1,1
1,5

204/A
205/A
206/A
404/A
405/A
803/A

HP
0,75
1
1,2
1,2
1,5
1,5
2

min
2,3
3
3,8
2,1
3
2
2,4

max
3,8
4,5
5,8
3,6
4,5
2,7
3,6

Maximum capacity *
Hm

Vessel
Membrane
litre

Vessel

Q l/min
63
58
56
115
104
164
177

23
31
39
21
31
20
24

40
40
50
60
80
200
200

100
100
100
100
300
300
300

litre

* Maximum pumps flow at minimum setting pressure switch.

BS2F

BSM2F

Mains: 400V 3~
Motor: 400V 3~
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F

2MXSU
2MXSU
2MXSU
2MXSU
2MXSU
2MXSU
2MXSU

204/A
205/A
206/A
404/A
405/A
803/A
804/A

Alimentazione 230V 1~
Motore 230V 1~
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F

2MXSU
2MXSU
2MXSU
2MXSU
2MXSU
2MXSU

Pres. switch 1
bar

Motor
kW
0,55 x2
0,75 x2
0,9 x2
0,9 x2
1,1 x2
1,1 x2
1,5 x2

204/A
205/A
206/A
404/A
405/A
803/A

HP
0,75 x2
1 x2
1,2 x2
1,2 x2
1,5 x2
1,5 x2
2 x2

min
2,3
3
3,8
2,1
3
2
2,4

max
3,8
4,5
5,8
3,6
4,5
2,7
3,6

Pres. switch 2
bar
min
1,8
2,5
3,5
1,7
2,5
1,6
2

max
3,3
4
5,5
3,2
4
2,3
3,2

Maximum capacity *
Hm

Vessel
Membrane
litre

Vessel

Q l/min
143
133
121
251
233
368
378

18
25
36
17
25
16
20

40
40
50
60
80
200
200

100
100
100
100
300
300
300

litre

* Maximum pumps flow at minimum setting pressure of 2 nd pressure switch.

BS3F
Mains: 400V 3~
Motor: 400V 3~
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F

3MXSU
3MXSU
3MXSU
3MXSU
3MXSU
3MXSU
3MXSU

204/A
205/A
206/A
404/A
405/A
803/A
804/A

Pres. switch 1
bar

Motor
kW
0,55 x3
0,75 x3
0,9 x3
0,9 x3
1,1 x3
1,1 x3
1,5 x3

HP
0,75 x3
1 x3
1,2 x3
1,2 x3
1,5 x3
1,5 x3
2 x3

min
2,3
3
3,8
2,1
3
2
2,6

Pres. switch 2
bar

max
3,8
4,5
5,8
3,6
4,5
2,7
3,6

min
1,8
2,5
3,5
1,7
2,5
1,6
2,2

max
3,3
4
5,5
3,2
4
2,3
3,2

Pres. switch 3
bar
min
1,3
2
3,2
1,2
2
1,2
1,8

max
2,8
3,5
5,2
2,7
3,5
1,9
2,8

Maximum capacity *
Q l/min
235
220
194
403
379
581
579

Hm
13
20
33
12
20
12
18

Vessel
Membrane
litre

Vessel

40
40
40
60
80
200
200

100
100
100
100
200
200
300

litre

* Maximum pumps flow at minimum setting pressure of 3 nd pressure switch.

PUMPS Nos

BS1V

BS2V
BS1V1F

BS3V
BS1V2F

BS4V
BS1V3F

BS5V
BS1V4F

(*) SYSTEMS WITH:


1 variable speed pump three-phase motor
1 fixed speed pump single-phase motor
Power supply to control panel 230 V single-phase

BS6V
BS1V5F

NM 40/20A/A
NM 40/25B/C
NM 40/25A/C
NM 50/16B/B
PUMP TYPE
NM 50/16A/B
NM 50/20B/C
NM 50/20A/C
NM 50/25C/C
NM 50/25B/C
NM 50/25A/C
NM 65/16B/C
NM 65/16AR
NM 65/16A/C
NM 65/20C/B

7,5
10
11
15
15
20
P2
5,5
7,5
For each pump
7,5
10
9,2
12,5
11
15
11
15
15
20
18,5
25
11
15
15
20
15
20
15
20

(**) Three-phase motor 230 V.


Power supply to control panel: - 230 V three-phase
- 230 V single-phase
Frequency converter output is alwais 230 V three-phase.

581

51

BS. MXSU

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

DN 2

Hf
Hv

h2

DN1
h1
L1

TYPE

Connection
Collettori

TYPE

BS.. 1MXSU 204/A


BS.. 1MXSU 205/A
BS.. 1MXSU 206/A
BS.. 1MXSU 404/A
BS.. 1MXSU 405/A
BS.. 1MXSU 803/A
BS.. 1MXSU 804/A

BSM.. 1MXSU 204/A


BSM.. 1MXSU 205/A
BSM.. 1MXSU 206/A
BSM.. 1MXSU 404/A
BSM.. 1MXSU 405/A
BSM.. 1MXSU 803/A
BSM.. 1MXSU 804/A

mm
Hf

Hv

h1

G 1 1/4 G 1 1/4

875

1045

75

G 1 1/4 G 1 1/4

875

1045

75

G 1 1/4 G 1 1/4

875

1045

75

DN 1

DN 2

h2
600
625
650
600
625
625
625

L1

m1

625

365

625

365

625

365

weight
Peso
kg
-

Dimensions not binding to be verified when ordering

L2

h2

Hf
Hv

h1
4.93.234.4

m1
L1f
L1v

TYPE
BS.. 2MXSU 204/A
BS.. 2MXSU 205/A
BS.. 2MXSU 206/A
BS.. 2MXSU 404/A
BS.. 2MXSU 405/A
BS.. 2MXSU 803/A
BS.. 2MXSU 804/A
Dimensions not binding

TYPE

B2

Connection
Collettori

DN 1
BSM.. 2MXSU 204/A
BSM.. 2MXSU 205/A
G2
BSM.. 2MXSU 206/A
BSM.. 2MXSU 404/A
G2
BSM.. 2MXSU 405/A
BSM.. 2MXSU 803/A
G2
BSM.. 2MXSU 804/A
to be verified when ordering

mm

DN 2

Hf

Hv

h1

G2

865

1135

66

G2

865

1135

66

G2

865

1135

66

582

h2
657
681
705
657
681
681
681

L1f

L1v

L2

m1

690

740

300

234

600

625

690

740

300

234

600

625

690

740

300

234

600

625

weight
Peso
kg
50 - 50
52 - 52
54 - 55
52 - 53
53 - 54
52 - 53
57

BS. MXSU

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

L2

Hf
Hv
h2

h1
4.93.234.6

m1
L1f
L1v

TYPE
BS.. 3MXSU 204/A
BS.. 3MXSU 205/A
BS.. 3MXSU 206/A
BS.. 3MXSU 404/A
BS.. 3MXSU 405/A
BS.. 3MXSU 803/A
BS.. 3MXSU 804/A
Dimensions not binding

B2

Connection
Collettori

mm

DN 1

DN 2

Hf

Hv

h1

G 2 1/2

G2

1090

1260

91

G 2 1/2

G2

1090

1260

91

G 2 1/2

G2

1090

1260

91

h2
657
681
705
657
681
690
690

L1f

L1v

L2

m1

735

805

305

406

950

1000

735

805

305

406

950

1000

735

805

305

406

950

1000

weight
Peso
kg
85
88
91
88
89
88
96

to be verified when ordering

51

583

BS. MXV-B

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
5 U.S. g.p.m. 10
4

20

30

5 Imp. g.p.m. 10

20

40 50
30

40 50

100

200
100

120
100

300

H
m

200

1-3 MXV-B
50
H
40

ft
100

30

20

15

3
m3/h 2
Q
20 l/min 30 40 50

5
100

10
150 200

20
30
300 400 500

40 50

50

72.1002/1

Operation
BS 1-6F

Electrical control boards:


- with microprocessor for fixed speed pump units (see page 486). Motor
starting is D.O.L. up to 5,5 kW and Y/ for power rating 7,5 kW.
- with frequency converter for variable speed pump units (see page 487).

Pressure boosting sets with 1 to 6 fixed speed pump.


Sets with 4,5 and 6 pumps on request.
Depending on the reduction of the pressure in the system,
the pressure switches determine the starting up of the pumps
in sequence and the microprocessor alternates the starts.

The unit includes one pressure gauge and three adjustable differential
pressure switches or pressure transducer (for sets with frequency converter).

BS1V2-5F Pressure boosting sets with 1 variable speed pump (with


frequency converter into the control panel) and from 1 to 5
fixed speed pumps
Sets with 4,5 and 6 pumps on request.
According to the water consumption, one or more pumps
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure.
BS1-6V

Applications
To supply water in civil and industrial buildings.
As pressure boosting pump to increase water pressure when needed
(follow local rules).

Pressure boosting sets with 1 to 6 variable speed pumps


(with frequency converter into the control panel).
Sets with 4,5 and 6 pumps on request.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.

Motors
2-pole induction motors, 50 Hz, n 2900 rpm, suitable for operation with
frequency converter.
- Three-phase 230/400V 10% up to 3 kW;
400/690V 10% for 4 kW to 7,5 kW;
- Single-phase 230 V 10%, with thermal protector.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.

Construction
- Automatic pressure boosting plant consisting of 1 vertical multi-stage
close coupled pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.

Vessels on request
- Automatic pressure boosting plant consisting of 2 to 6 vertical multistage close coupled pumps complete with ball, non return valve on the
suction side and ball valves on the delivery side.
Suction and delivery manifolds are in AISI 304.
Connections are located on the delivery manifold for the installation of
20 litres cylindrical vessels:
- 2 vessels (for 2MXV-B 25-32-40), 1 vessel (for 2MXV-B 50).
- 3 vessels (for 3MXV-B 25-32-40), 2 vessels (for 3MXV-B 50).

When installing the unit, connect in the delivery section to a diaphragm


or galvanised tank.
The recommended sized are shown in the following page.

Special features on request


Pressure boosting sets with 4,5 and 6 pumps.

584

BS. MXV-B

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

20

30
20

40

50

30

60

40

50

140

U.S. g.p.m.

Imp. g.p.m.

30

40
30

50

60

40

70

50

80

60

90
70

100
80

110
90

140

1-3MXV-B 25

400

120

1-3MXV-B 32

120

100

400

100
300

10

80

300
80

ft

ft

60

200

60

40

200

40

100

20

10

100

20

0
0

m 3/h
Q l/min

3
50

6
100

9
150

0
15
250

12
200

0
0

6
m3/h
Q l/min
100

12
200

18
300

24
400

72.951.1C

0 U.S. g.p.m. 40
0 Imp. g.p.m.

60
40

80
60

100
80

120

140

100

160

120

27

72.951.2C

180

140

U.S. g.p.m.

Imp. g.p.m.

100

200
100

150

300
200

250

140

140

1-3MXV-B 40

400

120

1-3MXV-B 50

120

400

Series cannot be sold in the EU

ft
100

100

10

10

300

ft

H
m

80

80

8
H

200

60

ft

5
40

4
100

100

3
20

20

200

5
40

300

51
0
0

/h
Qm
l/min
3

12
200

18
300

24
400

30
500

36
600

0
42
700
72.951.3C

0
0

3
15
Q m /h 300

l/min

30

45
600

60
900

75
1200
72.953.1C

585

BS. MXV-B

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS1F

BSM1F

Mains: 400V 3~
Motor: 400V 3~
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F
BS1F

1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B
1MXV-B

25-204
25-205
25-206
25-207
25-208
25-210
32-404
32-405
32-406
32-407
32-408/A
32-410/A
40-804
40-805/A
40-806/A
40-807/A
40-808/A
40-810/A
50-1803/A
50-1804/A
50-1805/A
50-1806/A
50-1807/A
50-1808/A
50-1809/A
50-1810/A

Mains: 230V 1~
Motor: 230V 1~
BSM1F
BSM1F
BSM1F
BSM1F
BSM1F
BSM1F
BSM1F
BSM1F
BSM1F
BSM1F

Pres. switch 1
bar

Motor

1MXV-BM
1MXV-BM
1MXV-BM
1MXV-BM
1MXV-BM
1MXV-BM
1MXV-BM
1MXV-BM
1MXV-BM
1MXV-BM

25-204
25-205
25-206
25-207
25-208
25-210
32-404
32-405
32-406
32-407

BSM1F 1MXV-BM 40-804

kW
0,75
0,75
1,1
1,1
1,5
1,5
1,1
1,1
1,5
1,5
2,2
2,2
1,5
2,2
2,2
3
3
3,7
2,2
3
3,7
4
5,5
5,5
7,5
7,5

HP
1
1
1,5
1,5
2
2
1,5
1,5
2
2
3
3
2
3
3
4
4
5
3
4
5
5,5
7,5
7,5
10
10

min
2,5
3,5
4
5
6
6,5
2,3
3,4
4
5
6
6,5
2,5
3,5
4
5
6
7,5
1,5
2,5
3,5
4
5
6
7
8

max
4
5
6
7
8
9,5
3,8
4,9
6
7
8
9,5
4
5
6
7
8
10,5
3
4
5
6
7
8
9
10

Maximum capacity *
Hm

Vessel
Membrane
litre

Vessel

Q l/min
62
56
59
55
51
60
114
103
105
99
93
108
214
211
211
208
199
199
395
373
357
359
358
341
343
333

25
36
41
51
61
66
23
35
41
51
61
66
25
36
41
51
61
76
15
25
36
41
51
61
71
82

40
50
50
50
60
60
80
100
100
100
150
150
200
300
300
300
300
500
300
500
500
500
750
750
1000
1000

100
100
100
100
100
100
100
100
100
300
300
300
300
500
500
500
500
800
500
800
1000
800
1000
1000
2000
2000

litre

* Maximum pumps flow at minimum setting pressure switch.

BS2F

BSM2F

Mains: 400V 3~
Motor: 400V 3~
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F
BS2F

2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B
2MXV-B

25-204
25-205
25-206
25-207
25-208
25-210
32-404
32-405
32-406
32-407
32-408/A
32-410/A
40-804
40-805/A
40-806/A
40-807/A
40-808/A
40-810/A
50-1803/A
50-1804/A
50-1805/A
50-1806/A
50-1807/A
50-1808/A
50-1809/A
50-1810/A

Alimentazione 230V 1~
Motore 230V 1~
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F
BSM2F

2MXV-BM
2MXV-BM
2MXV-BM
2MXV-BM
2MXV-BM
2MXV-BM
2MXV-BM
2MXV-BM
2MXV-BM
2MXV-BM

25-204
25-205
25-206
25-207
25-208
25-210
32-404
32-405
32-406
32-407

BSM2F 2MXV-BM 40-804

Motor
kW
0,75 x2
0,75 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
2,2 x2
2,2 x2
1,5 x2
2,2 x2
2,2 x2
3 x2
3 x2
3,7 x2
2,2 x2
3 x2
3,7 x2
4 x2
5,5 x2
5,5 x2
7,5 x2
7,5 x2

HP
1 x2
1 x2
1,5 x2
1,5 x2
2 x2
2 x2
1,5 x2
1,5 x2
2 x2
2 x2
3 x2
3 x2
2 x2
3 x2
3 x2
4 x2
4 x2
5 x2
3 x2
4 x2
5 x2
5,5 x2
7,5 x2
7,5 x2
10 x2
10 x2

Pres. switch 1
bar

Pres. switch 2
bar

min
2,5
3,5
4
5
6
6,5
2,3
3,4
4
5
6
6,5
2,5
3,5
4
5
6
8
1,5
2,5
3,5
4
5
6
7
8

min
2,2
3
3,5
4,5
5,5
6
1,8
3
3,5
4,5
5,5
6
2,2
3
3,5
4,5
5,5
7,5
1,2
2,2
3
3,5
4,5
5,5
6,5
7,5

* Maximum pumps flow at minimum setting pressure of 2 nd pressure switch.

586

max
4
5
6
7
8
9,5
3,8
4,9
6
7
8
9,5
4
5
6
7
8
10
3
4
5
6
7
8
9
10

max
3,7
4,5
5,5
6,5
7,5
9
3,3
4,5
5,5
6,5
7,5
9
3,7
4,5
5,5
6,5
7,5
9,5
2,7
3,7
4,5
5,5
6,5
7,5
8,5
9,5

Maximum capacity *
Q l/min

Hm

Vessel
Membrane
litre

135
128
130
122
113
128
253
226
232
218
205
229
435
438
435
434
418
399
822
784
777
771
764
733
731
711

22
31
36
46
56
61
18
31
36
46
56
61
22
31
36
46
56
76
12
22
31
36
46
56
66
76

40
50
50
50
60
60
80
100
100
100
150
150
200
300
300
300
300
500
300
500
500
500
750
750
1000
1000

Vessel
100
100
100
100
100
100
100
100
100
300
300
300
300
500
500
500
500
800
500
800
1000
800
1000
1000
2000
2000

litre

BS. MXV-B

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS3F
Mains: 400V 3~
Motor: 400V 3~
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS2F
BS2F
BS2F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F
BS3F

3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B
3MXV-B

Pres. switch 1
bar

Motor
kW
0,75 x3
0,75 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
2,2 x3
2,2 x3
1,5 x3
2,2 x3
2,2 x3
3 x3
3 x3
3,7 x3
2,2 x3
3 x3
3,7 x3
4 x3
5,5 x3
5,5 x3
7,5 x3
7,5 x3

25-204
25-205
25-206
25-207
25-208
25-210
32-404
32-405
32-406
32-407
32-408/A
32-410/A
40-804
40-805/A
40-806/A
40-807/A
40-808/A
40-810/A
50-1803/A
50-1804/A
50-1805/A
50-1806/A
50-1807/A
50-1808/A
50-1809/A
50-1810/A

HP
1 x3
1 x3
1,5 x3
1,5 x3
2 x3
2 x3
1,5 x3
1,5 x3
2 x3
2 x3
3 x3
3 x3
2 x3
3 x3
3 x3
4 x3
4 x3
5 x3
3 x3
4 x3
5 x3
5,5 x3
7,5 x3
7,5 x3
10 x3
10 x3

min
2,5
3,5
4,5
5,5
6,5
6,5
2,3
3,4
4,4
5,5
6,5
6
2,5
3,5
4,5
5,5
6,5
8
1,8
2,5
3,5
4,5
5,5
6,5
7
8

Pres. switch 2
bar

max
4
5
6
7
8
9,5
3,8
4,9
5,9
7
8
9
4
5
6
7
8
10
3
4
5
6
7
8
9
10

min
2,2
3,2
4,2
5,2
6,2
6
2
3,1
4,1
5,2
6,2
5,5
2,2
3,2
4,2
5,2
6,2
8,5
1,5
2,2
3,2
4,2
5,2
6,2
6,5
7,5

max
3,7
4,7
5,7
6,7
7,7
9
3,5
4,6
5,6
6,7
7,7
8,5
3,7
4,7
5,7
6,7
7,7
10,5
2,7
3,7
4,7
5,7
6,7
7,7
8,5
9,5

Pres. switch 3
bar
min
1,9
2,9
3,9
4,9
5,9
5,5
1,7
2,8
3,8
4,9
5,9
5
1,9
2,9
3,9
4,9
5,9
8
1,2
1,9
2,9
3,9
4,9
5,9
6
7

Maximum capacity *
Q l/min
216
197
180
168
157
203
385
353
330
304
285
373
643
658
640
632
604
565
1233
1218
1181
1096
1090
1041
1153
1123

max
3,4
4,4
5,4
6,4
7,4
8,5
3,2
4,3
5,3
6,4
7,4
8
3,4
4,4
5,4
6,4
7,4
10
2,4
3,4
4,4
5,4
6,4
7,4
8
9

Hm
19
30
40
50
60
56
17
29
39
50
60
51
19
30
40
50
60
82
12
19
30
40
50
60
61
71

Vessel
Membrane
litre

Vessel

40
50
50
50
60
60
80
100
100
100
150
150
200
300
300
300
300
500
300
500
500
500
750
750
1000
1000

100
100
100
100
100
100
100
100
100
300
300
300
300
500
500
500
500
800
500
800
1000
800
1000
1000
2000
2000

litre

* Maximum pumps flow at minimum setting pressure of 3 nd pressure switch.

Performance

BS..
PUMPS
Nos
N.
POMPE
1

BS1V

BS2V
BS3V
BS1V1F
BS1V2F
BSM1V1F*
BSM2V**

PUMPPOMPE
TYPE
TIPO

BS4V
BS1V3F

BS5V
BS1V4F

(*) SYSTEMS WITH:


1 variable speed pump three-phase motor
1 fixed speed pump single-phase motor
Power supply to control panel 230 V single-phase

BS6V
BS1V5F

MXV-B 25-204
MXV-B 25-205
MXV-B 25-206
MXV-B 25-207
MXV-B 25-208
MXV-B 25-210
MXV-B 32-404
MXV-B 32-405
MXV-B 32-406
MXV-B 32-407
MXV-B 32-408/A
MXV-B 32-410/A
MXV-B 40-804
MXV-B 40-805/A
MXV-B 40-806/A
MXV-B 40-807/A
MXV-B 40-808/A
MXV-B 40-810/A
MXV-B 50-1803/A
MXV-B 50-1804/A
MXV-B 50-1805/A
MXV-B 50-1806/A
MXV-B 50-1807/A
MXV-B 50-1808/A
MXV-B 50-1809/A
MXV-B 50-1810/A

PP22
ForPer
each
pump
pompa
kW
0,75
0,75
1,1
1,1
1,5
1,5
1,1
1,1
1,5
1,5
2,2
2,2
1,5
2,2
2,2
3
3
3,7
2,2
3
3,7
4
5,5
5,5
7,5
7,5

HP
1
1
1,5
1,5
2
2
1,5
1,5
2
2
3
3
2
3
3
4
4
5
3
4
5
5,5
7,5
7,5
10
10

(**) Three-phase motor 230 V.


Power supply to control panel: - 230 V three-phase
- 230 V single-phase
Frequency converter output is alwais 230 V three-phase.

587

51

BS. MXV-B

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

Hv
Hf

DN 2

DN1

h1
L1

m1

TYPE
BS1. 1MXV-B 25-204
BS1. 1MXV-B 25-205
BS1. 1MXV-B 25-206
BS1. 1MXV-B 25-207
BS1. 1MXV-B 25-208
BS1. 1MXV-B 25-210
BS1. 1MXV-B 32-404
BS1. 1MXV-B 32-405
BS1. 1MXV-B 32-406
BS1. 1MXV-B 32-407
BS1. 1MXV-B 32-408/A
BS1. 1MXV-B 32-410/A
BS1. 1MXV-B 40-804
BS1. 1MXV-B 40-805/A
BS1. 1MXV-B 40-806/A
BS1. 1MXV-B 40-807/A
BS1. 1MXV-B 40-808/A
BS1. 1MXV-B 40-810/A
BS1. 1MXV-B 50-1803/A
BS1. 1MXV-B 50-1804/A
BS1. 1MXV-B 50-1805/A
BS1. 1MXV-B 50-1806/A
BS1. 1MXV-B 50-1807/A
BS1. 1MXV-B 50-1808/A
BS1. 1MXV-B 50-1809/A
BS1. 1MXV-B 50-1810/A

Connection
Collettori

TYPE
BSM1. 1MXV-BM 25-204
BSM1. 1MXV-BM 25-205
BSM1. 1MXV-BM 25-206
BSM1. 1MXV-BM 25-207
BSM1. 1MXV-BM 25-208
BSM1. 1MXV-BM 25-210
BSM1. 1MXV-BM 32-404
BSM1. 1MXV-BM 32-405
BSM1. 1MXV-BM 32-406
BSM1. 1MXV-BM 32-407

mm

DN 1

DN 2

Hv

Hf

h1

L1

m1

G1

G1

1345

1065

120

625

410

G 1 1/4 G 1 1/4

1345

1065

120

625

410

G 1 1/2 G 1 1/2

1345

1065

125

625

410

135

625

410

BSM1. 1MXV-BM 40-804

1345
1065
G2

G2
1445
1445

Dimensions not binding to be verified when ordering

588

weight
Peso
kg
-

BS. MXV-B

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

Hf
Hv
DN 2
DN 1
h2
h1
4.93.233.N

m1

TYPE

Connection
Collettori
DN 1

BS.. 2MXV-B 25-204


BS.. 2MXV-B 25-205
BS.. 2MXV-B 25-206
BS.. 2MXV-B 25-207
BS.. 2MXV-B 25-208
BS.. 2MXV-B 25-210
BS.. 2MXV-B 32-404
BS.. 2MXV-B 32-405
BS.. 2MXV-B 32-406
BS.. 2MXV-B 32-407
BS.. 2MXV-B 32-408/A
BS.. 2MXV-B 32-410/A
BS.. 2MXV-B 40-804
BS.. 2MXV-B 40-805/A
BS.. 2MXV-B 40-806/A
BS.. 2MXV-B 40-807/A
BS.. 2MXV-B 40-808/A
BS.. 2MXV-B 40-810/A
BS.. 2MXV-B 50-1803/A
BS.. 2MXV-B 50-1804/A
BS.. 2MXV-B 50-1805/A
BS.. 2MXV-B 50-1806/A
BS.. 2MXV-B 50-1807/A
BS.. 2MXV-B 50-1808/A
BS.. 2MXV-B 50-1809/A
BS.. 2MXV-B 50-1810/A

BSM.. 2MXV-BM 25-204


BSM.. 2MXV-BM 25-205
BSM.. 2MXV-BM 25-206
BSM.. 2MXV-BM 25-207
BSM.. 2MXV-BM 25-208
BSM.. 2MXV-BM 25-210
BSM.. 2MXV-BM 32-404
BSM.. 2MXV-BM 32-405
BSM.. 2MXV-BM 32-406
BSM.. 2MXV-BM 32-407

B3f
B3v

L2

L1

TYPE

DN 2

G 1 1/2 G 1 1/2

G2

G2

B2

mm
Hf

Hv

h1

h2

L1

L2

m1

B2

B3f

B3v

875

1145

119

218

335

254

365

600

625

195

260

875

1145

119

225

360

295

365

600

625

195

260

BSM.. 2MXV-BM 40-804


G 2 1/2 G 2 1/2

G3

G3

875

965

1145

1445

124

225

245

225

400

495

305

405

365

550

600

700

625

950

195

160

260

220

weight
Peso
kg
105
107
109
111
118
108
111
115
118
121
116
119
121
143
145
208
228
238
240
262
264

Dimensions not binding to be verified when ordering

51

589

BS. MXV-B

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

Hf
Hv

DN 2
DN 1
h2
h1
4.93.233.N

m1
L1

TYPE
BS.. 3MXV-B 25-204
BS.. 3MXV-B 25-205
BS.. 3MXV-B 25-206
BS.. 3MXV-B 25-207
BS.. 3MXV-B 25-208
BS.. 3MXV-B 25-210
BS.. 3MXV-B 32-404
BS.. 3MXV-B 32-405
BS.. 3MXV-B 32-406
BS.. 3MXV-B 32-407
BS.. 3MXV-B 32-408/A
BS.. 3MXV-B 32-410/A
BS.. 3MXV-B 40-804
BS.. 3MXV-B 40-805/A
BS.. 3MXV-B 40-806/A
BS.. 3MXV-B 40-807/A
BS.. 3MXV-B 40-808/A
BS.. 3MXV-B 40-810/A
BS.. 3MXV-B 50-1803/A
BS.. 3MXV-B 50-1804/A
BS.. 3MXV-B 50-1805/A
BS.. 3MXV-B 50-1806/A
BS.. 3MXV-B 50-1807/A
BS.. 3MXV-B 50-1808/A
BS.. 3MXV-B 50-1809/A
BS.. 3MXV-B 50-1810/A

B3f
B3v

L2

Connection
Collettori

B2

mm

DN 1

DN 2

Hf

Hv

h1

h2

L1

L2

m1

B2

B3f

B3v

G2

G2

1090

1160

134

233

340

254

406

950

1000

220

220

G 2 1/2 G 2 1/2

G3

100

G3

100

1090

1090

1190

1160

1160

1360

134

139

280

240

260

280

Dimensions not binding to be verified when ordering

590

368

405

507

295

305

418

406

406

550

950

950

1200

1000

1000

1400

220

220

220

220

220

220

weight
Peso
kg
103
105
107
118
120
104
108
113
118
122
111
117
123
156
159
251
281
296
299
332
335

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
10 U.S. g.p.m. 30 40 50

100

10 Imp. g.p.m. 30 40 50

200 300 400500

100 150 200 300 400500

1000 1500
1000

140

400

120

H
ft
100
300
80

1-3MXV

H
m

200

60

40
100
20

0
2

m3 /h

Q l/min

5
10
20 30 40 50
100 150 200 300 400500
1000

100 150 200 300 400


2000 3000 5000
72.949.C

Operation
BS 1-6F

Electrical control boards:


- with microprocessor for fixed speed pump units (see page 486). Motor
starting is D.O.L. up to 5,5 kW and Y/ for power rating 7,5 up to 15 kW.
- with frequency converter for variable speed pump units (see page 487).

Pressure boosting sets with 1 to 6 fixed speed pump.


Sets with 4,5 and 6 pumps on request.
Depending on the reduction of the pressure in the system,
the pressure switches determine the starting up of the pumps
in sequence and the microprocessor alternates the starts.

The unit includes one pressure gauge and three adjustable differential
pressure switches or pressure transducer (for sets with frequency converter).

BS1V2-5F Pressure boosting sets with 1 variable speed pump (with


frequency converter into the control panel) and from 1 to 5
fixed speed pumps
Sets with 4,5 and 6 pumps on request.
According to the water consumption, one or more pumps
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure.
BS1-6V

Applications
To supply water in civil and industrial buildings.
As pressure boosting pump to increase water pressure when needed
(follow local rules).

Pressure boosting sets with 1 to 6 variable speed pumps


(with frequency converter into the control panel).
Sets with 4,5 and 6 pumps on request.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.

Motors
2-pole induction motors, 50 Hz, n 2900 rpm, suitable for operation with
frequency converter.
- Three-phase 230/400V 10% up to 3 kW;
400/690V 10% for 4 kW to 37 kW;
- Single-phase 230 V 10%, (on request).
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.

Construction
- Automatic pressure boosting plant consisting of 1 vertical multi-stage
close coupled pump complete with ball valve on the delivery side, suitable for installation of one cylindrical pressure vessel.

Vessels on request
- Automatic pressure boosting plant consisting of 2 to 6 vertical multistage close coupled pumps complete with ball, non return valve on the
suction side and ball valves on the delivery side.
Suction and delivery manifolds are in AISI 304.
Connections are located on the delivery manifold for the installation of
20 litres cylindrical vessels:
- 2 vessels (for 2MXV 25-32-40), 1 vessel (for 2MXV 50-65-80).
- 3 vessels (for 3MXV 25-32-40), 2 vessels (for 3MXV 50-65-80).

When installing the unit, connect in the delivery section to a diaphragm


or galvanised tank.
The recommended sized are shown in the following page.

Special features on request


Pressure boosting sets with 4,5 and 6 pumps.

591

51

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

20

30
20

40

50

30

60

40

50

140

U.S. g.p.m.

Imp. g.p.m.

30

40
30

50

60

40

70

50

80

60

90
70

100
80

110
90

140

1-3MXV 25

400

120

1-3MXV 32

120

100

400

100

12

12

300

300

10

80

80

ft

10

ft

60

200

60

40

200

40

100

20

100

20

0
0

m 3/h
Q l/min

3
50

6
100

9
150

0
15
250

12
200

0
0

6
m3/h
Q l/min
100

12
200

18
300

24
400

72.951.1C

0 U.S. g.p.m. 40
0 Imp. g.p.m.

60
40

80
60

100
80

120

140

100

160

120

27

72.951.2C

180

140

140

U.S. g.p.m.

Imp. g.p.m.

100

200
100

150

300
200

250

140

1-3MXV 40

1-3MXV 50-16

400

120

120

ft

8
11

100

100

10

300

300

80

400

80

ft

5
H

200

60

200

5
40

40

4
100

100
20

20

0
0

/h
Qm
l/min
3

12
200

18
300

24
400

30
500

36
600

0
42
700
72.951.3C

0
0

3
15
Q m /h 300

l/min

30

45
600

60
900

75
1200
72.953.1C

592

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
0

U.S. g.p.m.

Imp. g.p.m.

200

300
200

400

500

300

600

400

0 U.S. g.p.m. 200

500

0 Imp. g.p.m.

140

300

400
300

200

500
400

600

700

800

600

500

140

1-3MXV 65-32

1-3MXV 80-48

400

120

120

400

ft
100

100

300

80

80

m
200

200

60

4
3

40

40

100

100

20

H
ft

300

20

0
m 3/h
Q l/min
0
500

50

0
150
2500

100
1000

1500

2000

0 m3/h
40
Q
0 l/min 500

60
1000

80
100
1500

120
2000

140
160
2500

72.953.2C

U.S. g.p.m.

Imp. g.p.m.

500

72.953.3C

1000

0 U.S. g.p.m. 400

500

180
3000

1000

0 Imp. g.p.m.

140

600

400

800
600

1000
800

1200
1000

1400

1600

1200

140

1-3MXV 100-65

120

400

1-3MXV 100-90
120

400

5
5-2R

5-2R
100

100

4
80

300

4-2R

80

ft

H
ft

3-2R

40

40

2-2R

2-2R

100

100

20

4-2R

200

60

3-2R

300

m
200

60

20

0
0

60

m /h
Q l/min
1000
3

120
2000

180
3000

240
4000

0
280

72.951.2C

51
0 m3/h
80
Q
0 l/min 1000

120
2000

160
200
3000

240
4000

280
320
5000

360
6000
72.953.3C

593

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS1F
Mains: 400V 3~
Motor: 400V 3~
BS1F 1MXV 25-204/C
BS1F 1MXV 25-205/C
BS1F 1MXV 25-206/C
BS1F 1MXV 25-207/C
BS1F 1MXV 25-208/C
BS1F 1MXV 25-210/C
BS1F 1MXV 25-212/C
BS1F 1MXV 32-404/C
BS1F 1MXV 32-405/C
BS1F 1MXV 32-406/C
BS1F 1MXV 32-407/C
BS1F 1MXV 32-408/C
BS1F 1MXV 32-410/C
BS1F 1MXV 32-412/C
BS1F 1MXV 40-804/C
BS1F 1MXV 40-805/C
BS1F 1MXV 40-806/C
BS1F 1MXV 40-807/C
BS1F 1MXV 40-808/C
BS1F 1MXV 40-810/C
BS1F 1MXV 40-811/C
BS1F 1MXV 50-1603/C
BS1F 1MXV 50-1604/C
BS1F 1MXV 50-1605/C
BS1F 1MXV 50-1606/C
BS1F 1MXV 50-1607/C
BS1F 1MXV 50-1608/C
BS1F 1MXV 65-3202/C
BS1F 1MXV 65-3203/C
BS1F 1MXV 65-3204/C
BS1F 1MXV 65-3205/D
BS1F 1MXV 65-3206/D
BS1F 1MXV 65-3207/D
BS1F 1MXV 80-4802/C
BS1F 1MXV 80-4803/C
BS1F 1MXV 80-4804/D
BS1F 1MXV 80-4805/D
BS1F 1MXV 80-4806/D
BS1F 1MXV 80-4807/D

BSM1F
Mains: 230V 1~
Motor: 230V 1~
BSM1F 1MXV 25-204M/C
BSM1F 1MXV 25-205M/C
BSM1F 1MXV 25-206M/C
BSM1F 1MXV 25-207M/C
BSM1F 1MXV 25-208M/C

BSM1F 1MXV 32-404M/C


BSM1F 1MXV 32-405M/C
BSM1F 1MXV 32-406M/C
BSM1F 1MXV 32-407M/C

BSM1F 1MXV 40-804M/C

Motor
kW
0,75
0,75
1,1
1,1
1,5
1,5
2,2
1,1
1,1
1,5
1,5
2,2
2,2
3
1,5
2,2
2,2
3
3
4
4
3
4
5,5
5,5
7,5
7,5
4
5,5
7,5
11
11
15
5,5
7,5
11
15
15
18,5

HP
1
1
1,5
1,5
2
2
3
1,5
1,5
2
2
3
3
4
2
3
3
4
4
5,5
5,5
4
5,5
7,5
7,5
10
10
5,5
7,5
10
15
15
20
7,5
10
15
20
20
25

Pres. switch 1
bar
bar
min
max
2,5
4
3,5
5
4
6
5
7
6
8
6,5
8,5
8
10
2,3
3,8
3,4
4,9
4
6
5
7
6
8
7
9
8,5
10,5
2,5
4
3,5
5
4
6
5
7
6
8
8
10
9
11
3
4,5
4
6
5,5
7,5
6,5
9
7,5
9,5
8,5
11,5
2
3
3,3
4,8
4,5
6,5
6
8
6,5
9,5
7,5
10,5
2
3,2
3,5
5
4,5
6,5
6
8
6,5
9,5
8
11

* Maximum pumps flow at minimum setting pressure switch.

594

Maximum capacity *

Hm

Vessel
Membrane
litre

Vessel

Q l/min
62
56
59
55
51
60
59
114
103
105
99
93
101
100
214
211
211
208
199
188
183
367
371
343
348
353
353
704
670
662
627
682
683
917
840
894
848
911
882

25
36
41
51
61
66
82
23
35
41
51
61
71
87
25
36
41
51
61
82
92
31
41
56
66
76
87
20
34
46
61
66
76
20
36
46
61
66
82

40
50
50
60
100
100
200
100
100
100
100
200
300
300
200
300
300
500
500
1000
1000
500
750
1000
1000
1500
1500
1000
1500
1500
2000
3000
4000
1500
2000
3000
4000
5000
5000

100
100
100
100
100
200
200
100
200
200
200
300
500
500
300
500
500
800
800
1000
1000
800
1000
1500
1500
2000
2000
2000
3000
3000
4000
4000
5000
3000
3000
4000
5000
-

litre

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS2F

BSM2F

Mains: 400V 3~
Motor: 400V 3~
BS2F 2MXV 25-204/C
BS2F 2MXV 25-205/C
BS2F 2MXV 25-206/C
BS2F 2MXV 25-207/C
BS2F 2MXV 25-208/C
BS2F 2MXV 25-210/C
BS2F 2MXV 25-212/C
BS2F 2MXV 32-404/C
BS2F 2MXV 32-405/C
BS2F 2MXV 32-406/C
BS2F 2MXV 32-407/C
BS2F 2MXV 32-408/C
BS2F 2MXV 32-410/C
BS2F 2MXV 32-412/C
BS2F 2MXV 40-804/C
BS2F 2MXV 40-805/C
BS2F 2MXV 40-806/C
BS2F 2MXV 40-807/C
BS2F 2MXV 40-808/C
BS2F 2MXV 40-810/C
BS2F 2MXV 40-811/C
BS2F 2MXV 50-1603/C
BS2F 2MXV 50-1604/C
BS2F 2MXV 50-1605/C
BS2F 2MXV 50-1606/C
BS2F 2MXV 50-1607/C
BS2F 2MXV 50-1608/C
BS2F 2MXV 65-3202/C
BS2F 2MXV 65-3203/C
BS2F 2MXV 65-3204/C
BS2F 2MXV 65-3205/D
BS2F 2MXV 65-3206/D
BS2F 2MXV 65-3207/D
BS2F 2MXV 80-4802/C
BS2F 2MXV 80-4803/C
BS2F 2MXV 80-4804/D
BS2F 2MXV 80-4805/D
BS2F 2MXV 80-4806/D
BS2F 2MXV 80-4807/D
BS2F 2MXV 100-6502-2R
BS2F 2MXV 100-6502
BS2F 2MXV 100-6503-2R
BS2F 2MXV 100-6503
BS2F 2MXV 100-6504-2R
BS2F 2MXV 100-6504
BS2F 2MXV 100-6505-2R
BS2F 2MXV 100-6505
BS2F 2MXV 100-9002-2R
BS2F 2MXV 100-9002
BS2F 2MXV 100-9003-2R
BS2F 2MXV 100-9003
BS2F 2MXV 100-9004-2R
BS2F 2MXV 100-9004
BS2F 2MXV 100-9005-2R

Alimentazione 230V 1~
Motore 230V 1~
BSM2F 2MXV 25-204M/C
BSM2F 2MXV 25-205M/C
BSM2F 2MXV 25-206M/C
BSM2F 2MXV 25-207M/C
BSM2F 2MXV 25-208M/C

BSM2F 2MXV 32-404M/C


BSM2F 2MXV 32-405M/C
BSM2F 2MXV 32-406M/C
BSM2F 2MXV 32-407M/C

BSM2F 2MXV 40-804M/C

Motor
kW
0,75 x2
0,75 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
2,2 x2
1,1 x2
1,1 x2
1,5 x2
1,5 x2
2,2 x2
2,2 x2
3 x2
1,5 x2
2,2 x2
2,2 x2
3 x2
3 x2
4 x2
4 x2
3 x2
4 x2
5,5 x2
5,5 x2
7,5 x2
7,5 x2
4 x2
5,5 x2
7,5 x2
11 x2
11 x2
15 x2
5,5 x2
7,5 x2
11 x2
15 x2
15 x2
18,5 x2
7,5 x2
11 x2
15 x2
18,5 x2
18,5 x2
22 x2
30 x2
30 x2
11 x2
15 x2
18,5 x2
22 x2
30 x2
30 x2
37 x2

HP
1 x2
1 x2
1,5 x2
1,5 x2
2 x2
2 x2
3 x2
1,5 x2
1,5 x2
2 x2
2 x2
3 x2
3 x2
4 x2
2 x2
3 x2
3 x2
4 x2
4 x2
5,5 x2
5,5 x2
4 x2
5,5 x2
7,5 x2
7,5 x2
10 x2
10 x2
5,5 x2
7,5 x2
10 x2
15 x2
15 x2
20 x2
7,5 x2
10 x2
15 x2
20 x2
20 x2
25 x2
10 x2
15 x2
20 x2
25 x2
25 x2
30 x2
40 x2
40 x2
15 x2
20 x2
25 x2
30 x2
40 x2
40 x2
50 x2

Pres. switch 1
bar
min
max
2,5
4
3,5
5
4
6
5
7
6
8
6,5
8,5
8
10
2,3
3,8
3,4
4,9
4
6
5
7
6
8
7
9
8,5
10,5
2,5
4
3,5
5
4
6
5
7
6
8
8
10
9
11
3
4,5
4
6
5,5
7,5
6,5
9
7,5
9,5
8,5
11,5
2
3
3,3
4,8
4,5
6,5
6
8
6,5
9,5
7,5
10,5
2
3,2
3,5
5
4,5
6,5
6
8
6,5
9,5
8
11
2,2
2,8
3,8
4,4
4,3
4,9
5,8
6,7
7,2
8,4
7,7
8,9
8,3
9,8
9,8
11,3
2,9
3,9
3,7
5,2
4,6
6,1
6,2
7,7
7,4
8,9
8,5
10
9,5
11

Pres. switch 2
bar
min
max
2,2
3,7
3
4,5
3,5
5,5
4,5
6,5
5,5
7,5
6
8
7,5
9,5
1,8
3,3
3
4,5
3,5
5,5
4,5
6,5
5,5
7,5
6,5
8,5
8
10
2,2
3,7
3
4,5
3,5
5,5
4,5
6,5
5,5
7,5
7,5
9,5
8,5
10,5
2,5
4
3,5
5,5
5
7
6
8,5
7
9
8
11
1,7
2,7
2,8
4,3
4
6
5,5
7,5
6
9
7
10
1,6
2,8
3
4,5
4
6
5,5
7,5
9
6
10,5
7,5
2,5
1,9
4,1
3,5
4,6
4
6,2
5,3
7,8
6,6
8,3
7,1
9
7,5
10,5
9
3,4
2,4
4,5
3
5,6
4,1
6,9
5,4
8,1
6,6
9,3
7,8
10,3
8,8

Maximum capacity *

Q l/min

Hm

Vessel
Membrane
litre

135
128
130
122
113
128
125
253
226
232
218
205
216
213
435
438
435
434
418
399
390
785
782
734
734
739
734
1464
1439
1411
1344
1417
1411
1979
1852
1905
1809
1901
1838
2754
2783
3257
2765
2343
2786
2771
2782
3677
3862
3635
3620
3474
3441
3350

22
31
36
46
56
61
76
18
31
36
46
56
66
82
22
31
36
46
56
76
87
25
36
51
61
71
82
17
29
41
56
61
71
16
31
41
56
61
76
19
36
41
54
67
72
76
92
24
31
42
55
67
80
90

40
50
50
60
100
100
200
100
100
100
100
200
300
300
200
300
300
500
500
1000
1000
500
750
1000
1000
1500
1500
1000
1500
1500
2000
3000
4000
1500
2000
3000
4000
5000
5000
3000
-

Vessel

100
100
100
100
100
200
200
100
200
200
200
300
500
500
300
500
500
800
800
1000
1000
800
1000
1500
1500
2000
2000
2000
3000
3000
4000
4000
5000
3000
3000
4000
5000
-

litre

* Maximum pumps flow at minimum setting pressure of 2 nd pressure switch.

51

595

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS3F
Mains: 400V 3~
Motor: 400V 3~
BS3F 3MXV 25-204/C
BS3F 3MXV 25-205/C
BS3F 3MXV 25-206/C
BS3F 3MXV 25-207/C
BS3F 3MXV 25-208/C
BS3F 3MXV 25-210/C
BS3F 3MXV 25-212/C
BS3F 3MXV 32-404/C
BS3F 3MXV 32-405/C
BS3F 3MXV 32-406/C
BS3F 3MXV 32-407/C
BS3F 3MXV 32-408/C
BS3F 3MXV 32-410/C
BS3F 3MXV 32-412/C
BS3F 3MXV 40-804/C
BS3F 3MXV 40-805/C
BS3F 3MXV 40-806/C
BS3F 3MXV 40-807/C
BS3F 3MXV 40-808/C
BS3F 3MXV 40-810/C
BS3F 3MXV 40-811/C
BS3F 3MXV 50-1603/C
BS3F 3MXV 50-1604/C
BS3F 3MXV 50-1605/C
BS3F 3MXV 50-1606/C
BS3F 3MXV 50-1607/C
BS3F 3MXV 50-1608/C
BS3F 3MXV 65-3202/C
BS3F 3MXV 65-3203/C
BS3F 3MXV 65-3204/C
BS3F 3MXV 65-3205/D
BS3F 3MXV 65-3206/D
BS3F 3MXV 65-3207/D
BS3F 3MXV 80-4802/C
BS3F 3MXV 80-4803/C
BS3F 3MXV 80-4804/D
BS3F 3MXV 80-4805/D
BS3F 3MXV 80-4806/D
BS3F 3MXV 80-4807/D
BS3F 3MXV 100-6502-2R
BS3F 3MXV 100-6502
BS3F 3MXV 100-6503-2R
BS3F 3MXV 100-6503
BS3F 3MXV 100-6504-2R
BS3F 3MXV 100-6504
BS3F 3MXV 100-6505-2R
BS3F 3MXV 100-6505
BS3F 3MXV 100-9002-2R
BS3F 3MXV 100-9002
BS3F 3MXV 100-9003-2R
BS3F 3MXV 100-9003
BS3F 3MXV 100-9004-2R
BS3F 3MXV 100-9004
BS3F 3MXV 100-9005-2R

Motor
kW
0,75 x3
0,75 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
2,2 x3
1,1 x3
1,1 x3
1,5 x3
1,5 x3
2,2 x3
2,2 x3
3 x3
1,5 x3
2,2 x3
2,2 x3
3 x3
3 x3
4 x3
4 x3
3 x3
4 x3
5,5 x3
5,5 x3
7,5 x3
7,5 x3
4 x3
5,5 x3
7,5 x3
11 x3
11 x3
15 x3
5,5 x3
7,5 x3
11 x3
15 x3
15 x3
18,5 x3
7,5 x3
11 x3
15 x3
18,5 x3
18,5 x3
22 x3
30 x3
30 x3
11 x3
15 x3
18,5 x3
22 x3
30 x3
30 x3
37 x3

HP
1 x3
1 x3
1,5 x3
1,5 x3
2 x3
2 x3
3 x3
1,5 x3
1,5 x3
2 x3
2 x3
3 x3
3 x3
4 x3
2 x3
3 x3
3 x3
4 x3
4 x3
5,5 x3
5,5 x3
4 x3
5,5 x3
7,5 x3
7,5 x3
10 x3
10 x3
5,5 x3
7,5 x3
10 x3
15 x3
15 x3
20 x3
7,5 x3
10 x3
15 x3
20 x3
20 x3
25 x3
10 x3
15 x3
20 x3
25 x3
25 x3
30 x3
40 x3
40 x3
15 x3
20 x3
25 x3
30 x3
40 x3
40 x3
50 x3

Pres. switch 1
bar
min
max
2,5
4
3,5
5
4
6
5
7
6
8
6,5
8,5
8
10
2,3
3,8
3,4
4,9
4
6
5
7
6
8
7
9
8,5
10,5
2,5
4
3,5
5
4
6
5
7
6
8
8
10
9
11
3
4,5
4
6
5,5
7,5
6,5
9
7,5
9,5
8,5
11,5
2
3
3,3
4,8
4,5
6,5
6
8
6,5
9,5
7,5
10,5
2
3,2
3,5
5
4,5
6,5
6
8
6,5
9,5
8
11
2,2
2,8
3,8
4,4
4,3
4,9
5,8
6,7
7,2
8,4
7,7
8,9
8,3
9,8
9,8
11,3
2,9
3,9
3,7
5,2
4,6
6,1
6,2
7,7
7,4
8,9
8,5
10
9,5
11

Pres. switch 2
bar
min
max
2,2
3,7
3
4,5
3,5
5,5
4,5
6,5
5,5
7,5
6
8
7,5
9,5
1,8
3,3
3
4,5
3,5
5,5
4,5
6,5
5,5
7,5
6,5
8,5
8
10
2,2
3,7
3
4,5
3,5
5,5
4,5
6,5
5,5
7,5
7,5
9,5
8,5
10,5
2,5
4
3,5
5,5
5
7
6
8,5
7
9
8
11
1,7
2,7
2,8
4,3
4
6
5,5
7,5
6
9
7
10
2,8
1,6
4,5
3
6
4
7,5
5,5
9
6
10,5
7,5
2,5
1,9
4,1
3,5
4,6
4
6,2
5,3
7,8
6,6
8,3
7,1
9
7,5
10,5
9
3,4
2,4
4,5
3
5,6
4,1
6,9
5,4
8,1
6,6
9,3
7,8
10,3
8,8

* Maximum pumps flow at minimum setting pressure of 3 nd pressure switch.

596

Pres. switch 3
bar
min
max
1,9
3,4
2,5
4
3
5
4
6
5
7
5,5
7,5
7
9
1,3
2,8
2,6
4,1
3
5
4
6
5
7
6
8
7,5
9,5
1,9
3,4
2,5
4
3
5
4
6
5
7
7
9
8
10
2
3,5
3
5
4,5
6,5
5,5
8
6,5
8,5
7,5
10,5
1,4
2,4
2,3
3,8
3,5
5,5
5
7
5,5
8,5
6,5
9,5
1,2
2,4
2,5
4
3,5
5,5
5
7
5,5
8,5
7
10
1,6
2,2
3,2
3,8
3,7
4,3
4,9
5,8
6
7,2
6,5
7,7
6,8
8,3
8,3
9,8
1,9
2,9
2,3
3,8
3,4
4,9
4,7
6,2
5,9
7,4
7,1
8,6
8,1
9,6

Maximum capacity *

Q l/min
216
212
211
199
186
203
196
406
365
372
353
332
343
335
643
648
649
658
647
624
613
1201
1200
1153
1146
1147
1136
2200
2208
2194
2117
2178
2168
3091
2971
2987
2854
2950
2855
4312
4334
4584
4293
3881
4319
4309
4315
5831
6046
5791
5800
5571
5542
5364

Hm
19
25
31
41
51
56
71
13
27
31
41
51
61
76
19
25
31
41
51
71
82
20
31
46
56
66
76
14
23
36
51
56
66
12
25
36
51
56
71
19
36
41
54
67
72
76
92
24
31
42
55
67
80
90

Vessel
Membrane
litre

Vessel

40
50
50
60
100
100
200
100
100
100
100
200
300
300
200
300
300
500
500
1000
1000
500
750
1000
1000
1500
1500
1000
1500
1500
2000
3000
4000
1500
2000
3000
4000
5000
5000
-

100
100
100
100
100
200
200
100
200
200
200
300
500
500
300
500
500
800
800
1000
1000
800
1000
1500
1500
2000
2000
2000
3000
3000
4000
4000
5000
3000
3000
4000
5000
-

litre

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS..
PUMPS
Nos
N.
POMPE
1

BS1V

BS2V
BS3V
BS1V1F
BS1V2F
BSM1V1F*
BSM2V**

BS4V
BS1V3F

(*) SYSTEMS WITH:


1 variable speed pump three-phase motor
1 fixed speed pump single-phase motor
Power supply to control panel 230 V
single-phase

PUMP
TYPE
TIPO POMPE
5

BS5V
BS1V4F

BS6V
BS1V5F

MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV
MXV

25-204/C
25-205/C
25-206/C
25-207/C
25-208/C
25-210/C
25-212/C
32-404/C
32-405/C
32-406/C
32-407/C
32-408/C
32-410/C
32-412/C
40-804/C
40-805/C
40-806/C
40-807/C
40-808/C
40-810/C
40-811/C
50-1603/C
50-1604/C
50-1605/C
50-1606/C
50-1607/C
50-1608/C
65-3202/C
65-3203/C
65-3204/C
65-3205/D
65-3206/D
65-3207/D
80-4802/C
80-4803/C
80-4804/D
80-4805/D
80-4806/D
80-4807/D
100-6502-2R
100-6502
100-6503-2R
100-6503
100-6504-2R
100-6504
100-6505-2R
100-6505
100-9002-2R
100-9002
100-9003-2R
100-9003
100-9004-2R
100-9004
100-9005-2R

PP2 2
pompa
ForPer
each
pump
kW
0,75
0,75
1,1
1,1
1,5
1,5
2,2
1,1
1,1
1,5
1,5
2,2
2,2
3
1,5
2,2
2,2
3
3
4
4
3
4
5,5
5,5
7,5
7,5
4
5,5
7,5
11
11
15
5,5
7,5
11
15
15
18,5
7,5
11
15
18,5
18,5
22
30
30
11
15
18,5
22
30
30
37

HP
1
1
1,5
1,5
2
2
3
1,5
1,5
2
2
3
3
4
2
3
3
4
4
5,5
5,5
4
5,5
7,5
7,5
10
10
5,5
7,5
10
15
15
20
7,5
10
15
20
20
25
10
15
20
25
25
30
40
40
15
20
25
30
40
40
50

(**) Three-phase motor 230 V.


Power supply to control panel:
- 230 V three-phase
- 230 V single-phase
Frequency converter output is alwais
230 V three-phase.

51

597

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and
weights

Hv
Hf

DN 2

DN1

h1
L1

m1

TYPE

Connection
Collettori

TYPE

BS1. 1MXV 25-204


BSM1. 1MXV 25-204M
BS1. 1MXV 25-205
BSM1. 1MXV 25-205M
BS1. 1MXV 25-206
BSM1. 1MXV 25-206M
BS1. 1MXV 25-207
BSM1. 1MXV 25-207M
BS1. 1MXV 25-208
BSM1. 1MXV 25-208M
BS1. 1MXV 25-210
BS1. 1MXV 25-212
BS1. 1MXV 32-404
BSM1. 1MXV 32-404M
BS1. 1MXV 32-405
BSM1. 1MXV 32-405M
BS1. 1MXV 32-406
BSM1. 1MXV 32-406M
BS1. 1MXV 32-407
BSM1. 1MXV 32-407M
BS1. 1MXV 32-408
BS1. 1MXV 32-410
BS1. 1MXV 32-412
BS1. 1MXV 40-804
BSM1. 1MXV 40-804M
BS1. 1MXV 40-805
BS1. 1MXV 40-806
BS1. 1MXV 40-807
BS1. 1MXV 40-808
BS1. 1MXV 40-810
BS1. 1MXV 40-811
Dimensions not binding to be verified when ordering

weight
Peso

mm

DN 1

DN 2

Hv

Hf

h1

L1

m1

G1

G1

1345

1065

120

625

410

G 1 1/4 G 1 1/4

1345

1065

120

625

410

G 1 1/2 G 1 1/2

1345

1065

125

625

410

Hv
Hf

DN1

DN 2

h1
L1

m1
Collettori

TYPE
BS.. 1MXV 50-1603
BS.. 1MXV 50-1604
BS.. 1MXV 50-1605
BS.. 1MXV 50-1606
BS.. 1MXV 50-1607
BS.. 1MXV 50-1608
BS.. 1MXV 65-3202
BS.. 1MXV 65-3203
BS.. 1MXV 65-3204
BS.. 1MXV 65-3205
BS.. 1MXV 65-3206
BS.. 1MXV 65-3207
BS.. 1MXV 80-4802
BS.. 1MXV 80-4803
BS.. 1MXV 80-4804
BS.. 1MXV 80-4805
BS.. 1MXV 80-4806
BS.. 1MXV 80-4807

Connection
DN 1

DN 2

mm
Hv

Hf

h1

L1

m1

225

950

550

240

950

550

240

950

550

1485
1155
G2

G2
1585
1585
1485

1155

1585
G 2 1/2 G 2 1/2
1685
1585
G3

G3

1685
1785

Dimensions not binding to be verified when ordering

598

1585
1155

1585

Peso
weight
kg

kg
-

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

Hf
Hv
DN 2
DN 1
h2
h1
4.93.233.N

m1

TYPE
BS.. 2MXV 25-204M
BS.. 2MXV 25-205M
BS.. 2MXV 25-206M
BS.. 2MXV 25-207M
BS.. 2MXV 25-208M
BS.. 2MXV 25-210M
BS.. 2MXV 25-212M
BS.. 2MXV 32-404M
BS.. 2MXV 32-405M
BS.. 2MXV 32-406M
BS.. 2MXV 32-407M

B2

Connection
Collettori
DN 1

BS.. 2MXV 25-204


BS.. 2MXV 25-205
BS.. 2MXV 25-206
BS.. 2MXV 25-207
BS.. 2MXV 25-208
BS.. 2MXV 25-210
BS.. 2MXV 25-212
BS.. 2MXV 32-404
BS.. 2MXV 32-405
BS.. 2MXV 32-406
BS.. 2MXV 32-407
BS.. 2MXV 32-408
BS.. 2MXV 32-410
BS.. 2MXV 32-412
BS.. 2MXV 40-804
BS.. 2MXV 40-805
BS.. 2MXV 40-806
BS.. 2MXV 40-807
BS.. 2MXV 40-808
BS.. 2MXV 40-810
BS.. 2MXV 40-811

B3f
B3v

L2

L1

TYPE

DN 2

G 1 1/2 G 1 1/2

G2

G2

weight
Peso

mm
Hf

Hv

h1

h2

L1

L2

m1

B2

B3f

B3v

875

1145

119

218

335

254

365

600

625

195

260

875

1145

119

225

360

295

365

600

625

195

260

BS.. 2MXV 40-804M

G 2 1/2 G 2 1/2

875

1145

124

245

400

305

365

600

625

195

260

kg
110
112
114
116
126

113
115
125
127
137

126
136
138
164
166

Dimensions not binding to be verified when ordering

51

599

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

OFF

ON

Hf
Hv

DN 1

DN 2

h1
B

m1
L1

BS.. 2MXV 50-1603


BS.. 2MXV 50-1604
BS.. 2MXV 50-1605
BS.. 2MXV 50-1606
BS.. 2MXV 50-1607
BS.. 2MXV 50-1608
BS.. 2MXV 65-3202
BS.. 2MXV 65-3203
BS.. 2MXV 65-3204
BS.. 2MXV 65-3205
BS.. 2MXV 65-3206
BS.. 2MXV 65-3207
BS.. 2MXV 80-4802
BS.. 2MXV 80-4803
BS.. 2MXV 80-4804
BS.. 2MXV 80-4805
BS.. 2MXV 80-4806
BS.. 2MXV 80-4807
BS.. 2MXV 100-6502-2R
BS.. 2MXV 100-6502
BS.. 2MXV 100-6503-2R
BS.. 2MXV 100-6503
BS.. 2MXV 100-6504-2R
BS.. 2MXV 100-6504
BS.. 2MXV 100-6505-2R
BS.. 2MXV 100-6505
BS.. 2MXV 100-9002-2R
BS.. 2MXV 100-9002
BS.. 2MXV 100-9003-2R
BS.. 2MXV 100-9003
BS.. 2MXV 100-9004-2R
BS.. 2MXV 100-9004
BS.. 2MXV 100-9005-2R

B4

B3f
B3v

B2

Connection
Collettori

weight
Peso

mm

DN 1

DN 2

Hf

Hv

h1

L1

L2

m1

B2

B3f

G3

G3

965

1445

225

455

355

550

700

950

160

965

160

1445

B3v

170

B4

225

170

ON

100

100
1445
965

125

125

240

OFF

TYPE

L2

560

425

550

750

950

160

1445

1445

200
170

1545

240

640

500

550

750

950

1545

170

170
220

200

150

150

950

950

200

200

950

950

* Dimensions on request

600

358
396
420
480

220

270

Dimensions not binding to be verified when ordering

kg
282
298
336
340

408
432
490
520

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

Hf
Hv

DN 2
DN 1
h2
h1
4.93.233.N

m1
L1

TYPE
BS.. 3MXV 25-204
BS.. 3MXV 25-205
BS.. 3MXV 25-206
BS.. 3MXV 25-207
BS.. 3MXV 25-208
BS.. 3MXV 25-210
BS.. 3MXV 25-212
BS.. 3MXV 32-404
BS.. 3MXV 32-405
BS.. 3MXV 32-406
BS.. 3MXV 32-407
BS.. 3MXV 32-408
BS.. 3MXV 32-410
BS.. 3MXV 32-412
BS.. 3MXV 40-804
BS.. 3MXV 40-805
BS.. 3MXV 40-806
BS.. 3MXV 40-807
BS.. 3MXV 40-808
BS.. 3MXV 40-810
BS.. 3MXV 40-811

B3f
B3v

L2

B2

Connection
Collettori

weight
Peso

mm

DN 1

DN 2

Hf

Hv

h1

h2

L1

L2

m1

B2

B3f

B3v

G2

G2

1090

1160

134

233

340

254

406

950

1000

220

220

G 2 1/2 G 2 1/2

G3

G3

1090

1090

1160

1160

134

139

240

260

368

405

295

305

406

406

950

950

1000

1000

220

220

220

220

kg
110
112
114
116
126

113
115
125
127
137

126
136
138
164
166

Dimensions not binding to be verified when ordering

51

601

OFF

ON

BS. MXV

Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions and weights

OFF

ON

Hf
Hv

DN 1

DN 2

h1
B

m1
L1

Connection
Collettori
DN 1
BS.. 3MXV 50-1603
BS.. 3MXV 50-1604
BS.. 3MXV 50-1605
BS.. 3MXV 50-1606
BS.. 3MXV 50-1607
BS.. 3MXV 50-1608
BS.. 3MXV 65-3202
BS.. 3MXV 65-3203
BS.. 3MXV 65-3204
BS.. 3MXV 65-3205
BS.. 3MXV 65-3206
BS.. 3MXV 65-3207
BS.. 3MXV 80-4802
BS.. 3MXV 80-4803
BS.. 3MXV 80-4804
BS.. 3MXV 80-4805
BS.. 3MXV 80-4806
BS.. 3MXV 80-4807
BS.. 3MXV 100-6502-2R
BS.. 3MXV 100-6502
BS.. 3MXV 100-6503-2R
BS.. 3MXV 100-6503
BS.. 3MXV 100-6504-2R
BS.. 3MXV 100-6504
BS.. 3MXV 100-6505-2R
BS.. 3MXV 100-6505
BS.. 3MXV 100-9002-2R
BS.. 3MXV 100-9002
BS.. 3MXV 100-9003-2R
BS.. 3MXV 100-9003
BS.. 3MXV 100-9004-2R
BS.. 3MXV 100-9004
BS.. 3MXV 100-9005-2R

DN 2

B4
B2

L2

weight

mm
Hf

Hv

h1

L1

L2

m1

B2

B3f

100

275

470

365

550

1200

1400

200
220

1540
1440

200
290

125

1160
150

487

550

1200

1400

200
220
200

1540
290

1540

672

150

170
220

1540
1540

655

515

550

1200

220

1400

200
220

200

1500

250

250

1500

* Dimensions on request

602

358
396
420
480

200

Dimensions not binding to be verified when ordering

Peso
kg
282
298
336
340

220

1540

125

B4

200

1160

1160

B3v
170

1440
100

B3f
B3v

408
432
490
520

* Cabinet version

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
50

100

50

U.S. g.p.m.

100

300

Imp. g.p.m.

500

1000

500

300

2000

1000

2000

120
100
90

300

80

H
m

H
m

1-3NM-NMD

60

200

50

40

100

30

90
80
70
20
10

m /h 20
3

Q l/min

200

30
500

40 50
1000

100
2000

200
3000

400
5000

600
10000
72.961.C

Operation
BS 1-6F

Electrical control boards:


- with microprocessor for fixed speed pump units (see page 486). Motor
starting is D.O.L. up to 5,5 kW and Y/ for power rating 7,5 up to 55 kW.
- with frequency converter for variable speed pump units (see page 487).

Pressure boosting sets with 1 to 6 fixed speed pump.


Sets with 4,5 and 6 pumps on request.
Depending on the reduction of the pressure in the system,
the pressure switches determine the starting up of the pumps
in sequence and the microprocessor alternates the starts.

The unit includes one pressure gauge and three adjustable differential
pressure switches or pressure transducer (for sets with frequency converter).

BS1V2-5F Pressure boosting sets with 1 variable speed pump (with


frequency converter into the control panel) and from 1 to 5
fixed speed pumps
Sets with 4,5 and 6 pumps on request.
According to the water consumption, one or more pumps
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure.
BS1-6V

Applications
To supply water in civil and industrial buildings.
As pressure boosting pump to increase water pressure when needed
(follow local rules).

Pressure boosting sets with 1 to 6 variable speed pumps


(with frequency converter into the control panel).
Sets with 4,5 and 6 pumps on request.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.

Motors
2-pole induction motors, 50 Hz, n 2900 rpm, suitable for operation with
frequency converter.
- Three-phase 230/400V 10% up to 3 kW;
400/690V 10% for 4 kW to 55 kW;
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.

Construction
- Automatic pressure boosting plant consisting of 1 centrifugal pump
complete with ball valve on the delivery side, suitable for installation of
one cylindrical pressure vessel.

Vessels on request
When installing the unit, connect in the delivery section to a diaphragm
or galvanised tank.
The recommended sized are shown in the following page.

- Automatic pressure boosting plant consisting of 2 to 6 centrifugal pumps


complete with ball, non return valve on the suction side and ball valves
on the delivery side.
Suction and delivery manifolds are in steel.
Connections are located on the delivery manifold for the installation of
20 litres cylindrical vessels:
- 2 vessels (for 2NM).
- 3 vessels (for 3NM).

Special features on request


Pressure boosting sets with 4,5 and 6 pumps.

603

51

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
38

32

1-3NM 32/16BE

1-3NM 32/16A/A

37

30

36
35

26

H m

H m

28

24

34
33
32

22

31
30

20
0 Q m 3/h 10

20

30

40

0 Q m 3/h 10

50

20

30

40

50

60

48

1-3NM 32/20C/A

46

1-3NM 32/20A/A
58

44

56
H m

H m

42
40

54
52

38

50

36

48

34
0 Q m 3/h 10

20

30

40

0 Q m 3/h 10

50

80

20

30

40

50

90

1-3NMD 32/210D/A

1-3NMD 32/210C/A

70
80

H m

H m

60
50

70

60

40
30

50
0 Q m 3/h

10

20

30

40

0 Q m 3/h 10

110

20

40

50

120

1-3NMD 32/210B/A

1-3NMD 32/210A/B

100

110

90

100

H m

H m

30

80

90

70

80
0 Q m 3/h 10

20

30

40

0 Q m 3/h 10

50

604

20

30

40

50

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
75

65

1-3NMD 40/180D/A

60
55

65

50

60
H m

H m

45
40
35

50
45

25

40
35
0 Q m 3/h

20

40

60

0 Q m 3/h

80

90

20

40

1-3NMD 40/180B/A

80

1-3NMD 40/180A/B

95
90

75

85
H m

80

70

80

65

75

60

70

55

65
0 Q m 3/h

20

40

32
30
28

60

80

0 Q m 3/h

20

40

60

80

40

1-3NM 40/16B/B

1-3NM 40/16A/B
35

26
24
22
20
18
16
14
12
10

H m

30
25
20
15
0 Q m 320
/h

40

60

80

100

120

140

0 Q m 3/h

50

100

150

60

55

1-3NM 40/20B/A

1-3NM 40/20A/A

50

55

45

50
H m

H m

60

100

85

H m

55

30

20

H m

1-3NMD 40/180C/A

70

40

45

51

40

35

35

30
0 Q m 3/h20

40

60

80

100

0 Q m 3/h

120

605

40

60

80

100

120

140

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
75

95

1-3NM 40/25A/C

1-3NM 40/25B/C

70

90

65
85
H m

H m

60
55

80

50
75

45
40

70
0 Q m 3/h

40

60

80

100

120

140

0 Q m 3/h

40

60

30

40

25

35

20

30

H m

H m

120

140

1-3NM 50/16A/B

1-3NM 50/16B/B

15

25

10

20
15

5
0 Q m 3/h 50

100

150

200

0 Q m 3/h 50

250

50

100

150

200

250

60

1-3NM 50/20A/C

1-3NM 50/20B/C

45

55

40

50

35

45

H m

H m

100

45

35

30

40

25

35

20

30
0 Q m 3/h 50

100

150

200

250

0 Q m 3/h 50

60

100

150

200

250

75

1-3NM 50/25C/C

55

1-3NM 50/25B/C

70

50

65

45

60

40

H m

H m

80

35

55

30

50

25

45

20
0 Q m 3/h 40

60

40

80 100 120 140 160 180 200 220

0 Q m 3/h 40

606

60

80 100 120 140 160 180 200 220

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
85

34

80

32

75

30

70

28

H m

H m

1-3NM 50/25A/C

65

26

60

24

55
0 Q 20
m 3/h 40

60

1-3NM 65/16B/C

22

80 100 120 140 160 180 200 220

0 Q m 3/h

100

200

300

400

42

38

1-3NM 65/16A/C

1-3NM 65/16AR
36

40

34
32

H m

H m

38
36

30
34

28

32

26
0 Q m 3/h

100

200

300

0 Q m 3/h

400

46

100

200

300

400

52

1-3NM 65/20C/B

1-3NM 65/20B/B

50

42

48
46
44
H m

H m

38
34

42
40
38

30

36
26

34
0 Q m 3/h

100

200

300

400

0 Q m 3/h

58

100

200

300

400

66

1-3NM 65/20A

56

1-3NM 65/25C

64

54

62

52

60
H m

H m

50
48
46

58
56

44

54

42

52

40

51

50
0 Q m 3/h

100

200

300

400

0 Q m 3/h
50

607

100

150

200

250

300

350

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
92

82

1-3NMS 65/250B

80
78

88
86

74

H m

H m

76

72

80

68

78

66
0 Q m 3/h
50

100

150

200

250

300

350

36

1-3NM 80/16B/C

100

150

200

250

300

350

1-3NM 80/16A/C

40

32

38

30

36
H m

H m

50
Q m 3/h

42

34

28

34

26

32

24

30

22

28
0 Q m 3/h100

200

300

400

500

600

0 Q m 3/h100

48

200

300

400

500

600

58

1-3NM 80/20B

46

1-3NMS 80/200A

56

44

54

42

52

40

50

H m

H m

84
82

70

38

48

36

46

34

44

32

42
0 Q m 3/h
100

200

300

400

500

0 Q m 3/h100

600

55

200

300

400

500

600

70

1-3NM 80/25E

50

1-3NMS 80/250D

65

45

60

40

55

H m

H m

1-3NMS 65/250A/A

90

35

50

30

45

25

40
0 Q m 3/h
100

200

300

400

500

600

0 Q m 3/h100

608

200

300

400

500

600

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Coverage chart
80

90

1-3NMS 80/250B

75

85

70

80

65

75

H m

H m

1-3NMS 80/250C

60

70

55

65

50

60
0 Q m 3/h
100

200

300

400

500

600

0 Q m 3/h100

200

300

400

500

600

100

1-3NMS 80/250A
95

H m

90
85
80
75
0 Q m 3/h100

200

300

400

500

600

51

609

BS. NM

Pressure boosting sets with 1 Centrifugal Pumps


Fixed speed pump

Performance
Mains: 400V 3~
Motor: 400V 3~
BS1F 1NM 32/16BE
BS1F 1NM 32/16A/A
BS1F 1NM 32/20C/A
BS1F 1NM 32/20A/A
BS1F 1NMD 32/210D/A
BS1F 1NMD 32/210C/A
BS1F 1NMD 32/210B/A
BS1F 1NMD 32/210A/B
BS1F 1NMD 40/180D/A
BS1F 1NMD 40/180C/A
BS1F 1NMD 40/180B/A
BS1F 1NMD 40/180A/B
BS1F 1NM 40/16B/B
BS1F 1NM 40/16A/B
BS1F 1NM 40/20B/A
BS1F 1NM 40/20A/A
BS1F 1NM 40/25B/C
BS1F 1NM 40/25A/C
BS1F 1NM 50/16B/B
BS1F 1NM 50/16A/B
BS1F 1NM 50/20B/C
BS1F 1NM 50/20A/C
BS1F 1NM 50/25C/C
BS1F 1NM 50/25B/C
BS1F 1NM 50/25A/C
BS1F 1NM 65/16B/C
BS1F 1NM 65/16AR
BS1F 1NM 65/16A/C
BS1F 1NM 65/20C/B
BS1F 1NM 65/20B/B
BS1F 1NM 65/20A
BS1F 1NM 65/25C
BS1F 1NMS 65/250B
BS1F 1NMS 65/250A
BS1F 1NM 80/16B/C
BS1F 1NM 80/16A/C
BS1F 1NM 80/20B
BS1F 1NMS 80/200A
BS1F 1NM 80/25E
BS1F 1NMS 80/250D
BS1F 1NMS 80/250C
BS1F 1NMS 80/250B
BS1F 1NMS 80/250A

Motor
kW
1,5
2,2
3
4
4
5,5
7,5
9,2
4
5,5
7,5
9,2
3
4
5,5
7,5
11
15
5,5
7,5
9,2
11
11
15
18,5
11
15
15
15
18,5
22
22
30
37
15
18,5
22
30
22
30
37
45
55

HP
2
3
4
5,5
5,5
7,5
10
12,5
5,5
7,5
10
12,5
4
5,5
7,5
10
15
20
7,5
10
12,5
15
15
20
25
15
20
20
20
25
30
30
40
50
20
25
30
40
30
40
50
60
75

Pres. switch 1
bar
min
max
2,2
2,8
2,7
3,4
3,2
4,2
4,5
5,5
5
7
6
8
8
10
9,5
11
4
5,5
5
6,5
6,7
8,2
7,5
9
1,5
2,5
2,4
3,4
3,7
4,7
4,4
5,4
5,6
6,6
7,7
8,7
1,7
2,7
2,5
3,5
3,5
4,5
4,2
5,2
4,1
5,1
5,6
6,6
6,6
7,6
2,2
3,2
2,6
3,6
3,1
4,1
3
4
3,6
4,6
4,2
5,2
5
6
6,6
7,6
7,7
8,7
2,5
3,5
2
3
3,3
4,3
4,3
5,3
3,8
4,8
4,5
6
5,5
7
6,5
8
8
9

Maximum capacity *

Hm

Vessel
Membrane
litre

Vessel

Q l/min
281
279
285
259
189
242
233
215
314
351
356
348
690
735
566
645
667
686
1171
1212
1087
1143
999
993
1175
2223
2238
2205
2101
2195
2238
1783
1812
1800
3391
2105
3040
3005
2465
2988
3091
3150
3094

22
28
33
46
51
61
82
97
41
51
68
76
15
24
38
45
57
78
17
25
36
43
42
57
67
22
27
32
31
37
43
51
67
78
25
20
34
44
39
46
56
66
82

500
500
500
750
500
500
750
1000
500
750
1000
1500
750
1000
1500
2000
3000
4000
2000
3000
3000
4000
4000
4000
5000
4000
5000
5000
-

800
1000
1000
1000
500
800
1000
1500
1000
1500
2000
2000
1500
2000
3000
4000
5000
4000
5000
5000
-

* Maximum pumps flow at minimum setting pressure switch.

610

litre

BS. NM

Pressure boosting sets with 2 Centrifugal Pumps


Fixed speed pump

Performance

BS2F
Mains: 400V 3~
Motor: 400V 3~
BS2F 2NM 32/16BE
BS2F 2NM 32/16A/A
BS2F 2NM 32/20C/A
BS2F 2NM 32/20A/A
BS2F 2NMD 32/210D/A
BS2F 2NMD 32/210C/A
BS2F 2NMD 32/210B/A
BS2F 2NMD 32/210A/B
BS2F 2NMD 40/180D/A
BS2F 2NMD 40/180C/A
BS2F 2NMD 40/180B/A
BS2F 2NMD 40/180A/B
BS2F 2NM 40/16B/B
BS2F 2NM 40/16A/B
BS2F 2NM 40/20B/A
BS2F 2NM 40/20A/A
BS2F 2NM 40/25B/C
BS2F 2NM 40/25A/C
BS2F 2NM 50/16B/B
BS2F 2NM 50/16A/B
BS2F 2NM 50/20B/C
BS2F 2NM 50/20A/C
BS2F 2NM 50/25C/C
BS2F 2NM 50/25B/C
BS2F 2NM 50/25A/C
BS2F 2NM 65/16B/C
BS2F 2NM 65/16AR
BS2F 2NM 65/16A/C
BS2F 2NM 65/20C/B
BS2F 2NM 65/20B/B
BS2F 2NM 65/20A
BS2F 2NM 65/25C
BS2F 2NMS 65/250B
BS2F 2NMS 65/250A
BS2F 2NM 80/16B/C
BS2F 2NM 80/16A/C
BS2F 2NM 80/20B
BS2F 2NMS 80/200A
BS2F 2NM 80/25E
BS2F 2NMS 80/250D
BS2F 2NMS 80/250C
BS2F 2NMS 80/250B
BS2F 2NMS 80/250A

Motor
kW
1,5 x2
2,2 x2
3 x2
4 x2
4 x2
5,5 x2
7,5 x2
9,2 x2
4 x2
5,5 x2
7,5 x2
9,2 x2
3 x2
4 x2
5,5 x2
7,5 x2
11 x2
15 x2
5,5 x2
7,5 x2
9,2 x2
11 x2
11 x2
15 x2
18,5 x2
11 x2
15 x2
15 x2
15 x2
18,5 x2
22 x2
22 x2
30 x2
37 x2
15 x2
18,5 x2
22 x2
30 x2
22 x2
30 x2
37 x2
45 x2
55 x2

HP
2 x2
3 x2
4 x2
5,5 x2
5,5 x2
7,5 x2
10 x2
12,5 x2
5,5 x2
7,5 x2
10 x2
12,5 x2
4 x2
5,5 x2
7,5 x2
10 x2
15 x2
20 x2
7,5 x2
10 x2
12,5 x2
15 x2
15 x2
20 x2
25 x2
15 x2
15 x2
15 x2
20 x2
25 x2
30 x2
30 x2
40 x2
50 x2
20 x2
25 x2
30 x2
40 x2
30 x2
40 x2
50 x2
60 x2
75 x2

Pres. switch 1
bar
min
max
2,2
2,8
2,7
3,4
3,2
4,2
4,5
5,5
5
7
6
8
8
10
9,5
11
4
5,5
5
6,5
6,7
8,2
7,5
9
1,5
2,5
2,4
3,4
3,7
4,7
4,4
5,4
5,6
6,6
7,7
8,7
1,7
2,7
2,5
3,5
3,5
4,5
4,2
5,2
4,1
5,1
5,6
6,6
6,6
7,6
2,2
3,2
2,6
3,6
3,1
4,1
3
4
3,6
4,6
4,2
5,2
5
6
6,6
7,6
7,7
8,7
2,2
3,2
2,8
3,8
3,3
4,3
4,3
5,3
3,8
4,8
4,5
6
5,5
7
6,5
8
8
9

Pres. switch 2
bar
min
max
2
2,6
2,5
3,2
3
4
4
5
4,5
6,5
5,5
7,5
7,5
9,5
9
10,5
3,5
5
4,5
6
6,2
7,7
7
8,5
1,2
2,2
2
3
3,3
4,3
3,9
4,9
5,1
6,1
7,3
8,3
1,2
2,2
2
3
3
4
3,7
4,7
3,6
4,6
5,1
6,1
6,1
7,1
1,7
2,7
2,1
3,1
2,6
3,6
2,5
3,5
3,2
4,2
3,8
4,8
4,6
5,6
6,2
7,2
7,3
8,3
1,7
2,7
2,3
3,3
3
4
4
5
3,2
4,2
4
5,5
5
6,5
6
7,5
7,5
8,5

Maximum capacity *

Q l/min

Hm

580
483
546
254
408
500
498
484
697
764
772
764
1410
1583
1227
1403
1452
1446
2609
2665
2466
2549
2236
2236
2426
4254
4111
4228
4422
4283
4044
3608
2970
2994
6712
6593
5836
5818
5691
6416
6407
6376
6400

20
25
31
41
46
56
76
92
36
46
63
71
12
20
34
40
52
74
12
20
31
38
37
52
62
17
21
27
25
33
39
47
63
74
20
23
31
41
33
41
51
61
76

Vessel
Membrane
litre
500
500
500
750
500
500
750
1000
500
750
1000
1500
750
1000
1500
2000
3000
4000
2000
3000
3000
4000
4000
4000
5000
4000
5000
5000
-

Vessel
litre
800
1000
1000
1000
500
800
1000
1500
1000
1500
2000
2000
1500
2000
3000
4000
5000
4000
5000
5000
--

* Maximum pumps flow at minimum setting pressure of 2 nd pressure switch.

51

611

BS. NM

Pressure boosting sets with 3 Centrifugal Pumps


Fixed speed pump

Performance

BS3F
Mains: 400V 3~
Motor: 400V 3~
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NMS
BS3F 3NMS
BS3F 3NM
BS3F 3NM
BS3F 3NM
BS3F 3NMS
BS3F 3NM
BS3F 3NMS
BS3F 3NMS
BS3F 3NMS
BS3F 3NMS

40/16B/B
40/16A/B
40/20B/A
40/20A/A
40/25B/C
40/25A/C
50/16B/B
50/16A/B
50/20B/C
50/20A/C
50/25C/C
50/25B/C
50/25A/C
65/16B/C
65/16AR
65/16A/C
65/20C/B
65/20B/B
65/20A
65/25C
65/250B
65/250A
80/16B/C
80/16A/C
80/20B
80/200A
80/25E
80/250D
80/250C
80/250B
80/250A

Motor
kW
3 x3
4 x3
5,5 x3
7,5 x3
11 x3
15 x3
5,5 x3
7,5 x3
9,2 x3
11 x3
11 x3
15 x3
18,5 x3
11 x3
15 x3
15 x3
15 x3
18,5 x3
22 x3
22 x3
30 x3
37 x3
15 x3
18,5 x3
22 x3
30 x3
22 x3
30 x3
37 x3
45 x3
55 x3

HP
4 x3
5,5 x3
7,5 x3
10 x3
15 x3
20 x3
7,5 x3
10 x3
12,5 x3
15 x3
15 x3
20 x3
25 x3
15 x3
20 x3
20 x3
20 x3
25 x3
30 x3
30 x3
40 x3
50 x3
20 x3
25 x3
30 x3
40 x3
30 x3
40 x3
50 x3
60 x3
75 x3

Pres. switch 1
bar
min
max
2
2,6
2,7
3,4
3,9
4,7
4,4
5,4
5,6
6,6
7,9
8,7
1,9
2,7
2,7
3,5
3,5
4,5
4,2
5,2
4,1
5,1
5,6
6,6
6,7
7,7
2,2
3,2
2,6
3,6
3,1
4,1
3
4
3,6
4,6
4,2
5,2
5
6
6,6
7,6
7,7
8,7
2,2
3,2
2,8
3,8
3,3
4,3
4,3
5,3
3,8
4,8
5
6
6
7
7
8
8
9

Pres. switch 2
bar
min
max
1,6
2,2
2,3
3
3,5
4,3
4
5
5,2
6,2
7,5
8,3
1,5
2,3
2,3
3,1
3
4
3,7
4,7
3,6
4,6
5,1
6,1
6,3
7,3
1,9
2,9
2,3
3,3
2,8
3,8
2,7
3,7
3,3
4,3
3,9
4,9
4,7
5,7
6,3
7,3
7,4
8,4
1,9
2,9
2,5
3,5
3,1
4,1
4,1
5,1
3,4
4,4
4,5
5,5
5,5
6,5
6,5
7,5
7,6
8,6

* Maximum pumps flow at minimum setting pressure of 3 nd pressure switch.

612

Pres. switch 3
bar
min
max
1,2
1,8
1,9
2,6
3,1
3,9
3,6
4,6
4,8
5,8
7,1
7,9
1,1
1,9
1,9
2,7
2,5
3,5
3,2
4,2
3,1
4,1
4,6
5,6
5,9
6,9
1,6
2,6
2
3
2,5
3,5
2,4
3,4
3
4
3,6
4,6
4,4
5,4
6
7
7,1
8,1
1,6
2,6
2,2
3,2
2,9
3,9
3,9
4,9
3
4
4
5
5
6
6
7
7,2
8,2

Maximum capacity *

Q l/min
2115
2393
1879
2120
2189
2155
3971
4039
3894
3903
3524
3497
3563
6128
5831
6053
6622
6090
5410
5290
3590
3651
7854
8027
8491
8488
8818
9625
9610
9564
9323

Hm
12
19
32
37
49
72
11
19
25
33
32
47
60
16
20
25
24
31
37
45
61
72
16
22
30
40
31
41
51
61
73

Vessel
Membrane
litre

Vessel

750
1000
1500
2000
3000
4000
2000
3000
3000
4000
4000
4000
5000
4000
5000
5000
-

1500
2000
3000
4000
5000
4000
5000
5000
-

litre

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Performance

BS..
PUMPS
Nos
N.
POMPE
1

BS1V

BS2V
BS1V1F

BS3V
BS1V2F

BS4V
BS1V3F

PUMP
TYPE
TIPO POMPE
5

BS5V
BS1V4F

BS6V
BS1V5F

NM 32/16BE
NM 32/16A/A
NM 32/20C/A
NM 32/20A/A
NMD 32/210D/A
NMD 32/210C/A
NMD 32/210B/A
NMD 32/210A/B
NMD 40/180D/A
NMD 40/180C/A
NMD 40/180B/A
NMD 40/180A/B
NM 40/16B/B
NM 40/16A/B
NM 40/20B/A
NM 40/20A/A
NM 40/25B/C
NM 40/25A/C
NM 50/16B/B
NM 50/16A/B
NM 50/20B/C
NM 50/20A/C
NM 50/25C/C
NM 50/25B/C
NM 50/25A/C
NM 65/16B/C
NM 65/16AR
NM 65/16A/C
NM 65/20C/B
NM 65/20B/B
NM 65/20A
NM 65/25C
NMS 65/250B
NMS 65/250A
NM 80/16B/C
NM 80/16A/C
NM 80/20B
NMS 80/200A
NM 80/25E
NMS 80/250D
NMS 80/250C
NMS 80/250B
NMS 80/250A

PP22
pompa
ForPer
each
pump
kW
1,5
2,2
3
4
4
5,5
7,5
9,2
4
5,5
7,5
9,2
3
4
5,5
7,5
11
15
5,5
7,5
9,2
11
11
15
18,5
11
15
15
15
18,5
22
22
30
37
15
18,5
22
30
22
30
37
45
55

HP
2
3
4
5,5
5,5
7,5
10
12,5
5,5
7,5
10
12,5
4
5,5
7,5
10
15
20
7,5
10
12,5
15
15
20
25
15
20
20
20
25
30
30
40
50
20
25
30
40
30
40
50
60
75

51

613

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions

Hv
Hf

DN 2

h2 DN 1

h1

m1

L1

Connection
Collettori
BS1F 1NM 32/16BE
BS1F 1NM 32/16A/A
BS1F 1NM 32/20C/A
BS1F 1NM 32/20A/A
BS1F 1NMD 32/210D/A
BS1F 1NMD 32/210C/A
BS1F 1NMD 32/210B/A
BS1F 1NMD 32/210A/B
BS1F 1NMD 40/180D/A
BS1F 1NMD 40/180C/A
BS1F 1NMD 40/180B/A
BS1F 1NMD 40/180A/B
BS1F 1NM 40/16B/B
BS1F 1NM 40/16A/B
BS1F 1NM 40/20B/A
BS1F 1NM 40/20A/A
BS1F 1NM 40/25B/C
BS1F 1NM 40/25A/C
BS1F 1NM 50/16B/B
BS1F 1NM 50/16A/B
BS1F 1NM 50/20B/C
BS1F 1NM 50/20A/C
BS1F 1NM 50/25C/C
BS1F 1NM 50/25B/C
BS1F 1NM 50/25A/C
BS1F 1NM 65/16B/C
BS1F 1NM 65/16AR
BS1F 1NM 65/16A/C
BS1F 1NM 65/20C/B
BS1F 1NM 65/20B/B
BS1F 1NM 65/20A
BS1F 1NM 65/25C
BS1F 1NMS 65/250B
BS1F 1NMS 65/250A
BS1F 1NM 80/16B/C
BS1F 1NM 80/16A/C
BS1F 1NM 80/20B
BS1F 1NMS 80/200A
BS1F 1NM 80/25E
BS1F 1NMS 80/250D
BS1F 1NMS 80/250C
BS1F 1NMS 80/250B
BS1F 1NMS 80/250A

weight
Peso

mm

DN 1

DN 2

Hv

Hf

h1

L1

m1

kg

G2

G1

1045

875

175

625

365

G2

G1

1045

875

205

625

365

625

365

625

365

135
155
155
175
135
155
155
175

G2

G 1 1/4

1045

875

G2

G 1 1/2

1045

875

G 2 1/2 G 1 1/2

1045

875

175

625

365

G 2 1/2 G 1 1/2

1145

875
1145

205

625

365

G 2 1/2 G 1 1/2

G 2 1/2

G2

G 2 1/2

G2

G 2 1/2

G2

G3

G 2 1/2

G3

G 2 1/2

G3

G 2 1/2

100

80

100

80

100

80

Dimensions not binding to be verified when ordering


* Cabinet version

614

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions

DN 2

Hv
Hf
DN 1
h2

h1

L1

L2

B2

m1

TYPE
BS2.. 2NM 32/16BE
BS2.. 2NM 32/16A/A
BS2.. 2NM 32/20C/A
BS2.. 2NM 32/20A/A
BS2.. 2NMD 32/210D/A
BS2.. 2NMD 32/210C/A
BS2.. 2NMD 32/210B/A
BS2.. 2NMD 32/210A/B
BS2.. 2NMD 40/180D/A
BS2.. 2NMD 40/180C/A
BS2.. 2NMD 40/180B/A
BS2.. 2NMD 40/180A/B
BS2.. 2NM 40/16B/B
BS2.. 2NM 40/16A/B
BS2.. 2NM 40/20B/A
BS2.. 2NM 40/20A/A
BS2.. 2NM 40/25B/C
BS2.. 2NM 40/25A/C
BS2.. 2NM 50/16B/B
BS2.. 2NM 50/16A/B
BS2.. 2NM 50/20B/C
BS2.. 2NM 50/20A/C
BS2.. 2NM 50/25C/C
BS2.. 2NM 50/25B/C
BS2.. 2NM 50/25A/C
BS2.. 2NM 65/16B/C
BS2.. 2NM 65/16AR
BS2.. 2NM 65/16A/C
BS2.. 2NM 65/20C/B
BS2.. 2NM 65/20B/B
BS2.. 2NM 65/20A
BS2.. 2NM 65/25C
BS2.. 2NMS 65/250B
BS2.. 2NMS 65/250A
BS2.. 2NM 80/16B/C
BS2.. 2NM 80/16A/C
BS2.. 2NM 80/20B
BS2.. 2NMS 80/200A
BS2.. 2NM 80/25E
BS2.. 2NMS 80/250D
BS2.. 2NMS 80/250C
BS2.. 2NMS 80/250B
BS2.. 2NMS 80/250A

Connection
Collettori
DN 1

DN 2

G3

G 21/2

G3

G 21/2

G3

G 21/2

G3

G 21/2

100

80

100

80

100

80

125

100

125

100

125

100

200

150

200

150

200

150

250

200

250

200

250

200

weight
Peso

mm
Hf
830
830
830
830
890
890
1370
1370
890
890
1370
1370
830
830
830
1310
1455
1455
975
1455
1455
1455
1455
1455
1455
1455
1455
1455
1455
1455
1655
1655
1655
1855
1455
1455
1655
1655
1655
1655
1855
1400*
1400*

Hv
1210
1210
1210
1210
1270
1370
1370
1670
1270
1370
1370
1670
1210
1210
1310
1310
1755
1755
1455
1455
1755
1755
1755
1755
1855
1755
1755
1755
1755
1855
1855
1855
1855
1600*
1755
1855
1855
1855
1855
1855
1600*
2100*
2100*

h1
165
165
195
195
245
272
272
307
245
272
272
307
187
187
215
215
340
240
315
215
315
215
340
240
240
320
320
220
340
240
260
360
260
310
340
240
360
260
360
260
310
310
310

h2

L1

345

385

365

385

380

460

460

475

380

480

400

500

440

500

435

515

455

515

480

515

525

625

550

625

575

625

615

730

640

730

670

730

Dimensions not binding to be verified when ordering


* Cabinet version

615

L2
330
370
395
395
420
440
440
515
415
435
435
510
395
395
425
425
540
615
425
425
540
540
545
620
620
540
540
615
615
615
725
725
725
975
620
620
725
725
725
725
975
1040
1110

m1

B2

kg

235

600

625

235

600

625

550

700

800

550

700

800

550

820

800

550

820

800

820

820

820

820

1020

1020

1200

1050

1050

1200

51

BS. NM

Pressure boosting sets with 1 to 3 Centrifugal Pumps


Fixed speed pump or Variable speed pump (frequency converter)

Dimensions

DN 2

Hv
Hf
DN 1
h2

h1

L1

L2

B2

m1

TYPE
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NMS
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NM
BS3.. 3NMS
BS3.. 3NMS
BS3.. 3NMS

40/16B/B
40/16A/B
40/20B/A
40/20A/A
40/25B/B
40/25A/B
50/16B/B
50/16A/B
50/20B/B
50/20A/B
50/25C/B
50/25B/B
50/25A/B
65/16B/A
65/16A/A
65/20C/A
65/20B/A
65/200A/A
65/250C/A
65/250B/A
65/250A
80/16B/A
80/16A/A
80/200B/A
80/200A/A
80/250E/A
80/250D/A
80/250C
80/250B
80/250A

Connection
Collettori
DN 1

DN 2

125

100

125

100

125

100

150

125

150

125

150

125

250

200

250

200

250

200

300 (1

250

(1

250

300 (1

250

300

mm
Hf
830
830
830
1410
1555
1555
975
1555
1555
1555
1555
1555
1755
1555
1555
1555
1755
1855
1855
1855
1545
1555
1755
1855
1855
1855
1855
1400*
1400*
1400*

Hv
1310
1310
1610
1610
1700*
1700*
1755
1755
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
1700*
-

h1
187
187
215
215
340
240
315
215
315
215
340
240
240
320
220
340
240
260
360
260
310
340
240
360
260
360
260
310
310
310

h2

L1

390

495

410

515

450

515

448

525

468

525

493

525

555

650

580

650

605

650

645

755

670

755

700

755

Dimensions not binding to be verified when ordering


(1

Only on request

* Cabinet version

616

L2
395
395
425
425
540
615
425
425
540
540
545
620
620
540
615
615
615
725
725
725
975
620
620
725
725
725
725
975
1040
1110

weight
Peso
kg

m1

B2

550

1340

800

550

1340

800

1340

1340

1340

1540

1540

1540

1900

1900

1900

1900

09/2016

AUE, AUD, AUED


UNI-EN 12845 fire-fighting systems

52

617

INDEX
AUE 11
UNI-EN 12845 units with 1 N series electric main pump

pag. 622

AUE 21
UNI-EN 12845 units with 2 N series electric main pumps

AUD 11
UNI-EN 12845 units with 1 N series main pump (diesel motor)

pag. 627

AUED 21
UNI-EN 12845 units with 2 N series main pumps
(electric and diesel motors)

618

AUE, AUD, AUED


UNI-EN 12845 fire-fighting systems
Construction

19

17

16

17

18

14
13
10
11
12
9
15
8
4

3.93.131

20

1) Main pump
2) Main pump
3) Jockey pump
4) Butterfly valve in suction section (on request only for installation with positive head)
5) Vacuometer
6) Pressure gauge in delivery section
7) Ball valve for draining
8) Adjusted diaphragm
9) Non-return valve (accessible)
10) Butterfly valve for capacity-check system (on request)
11) Manifold for flow meter (on request)
12) Flow meter (on request)
13) Butterfly valve or ball valve in delivery section
14) Delivery manifold
15) Test circuit (manual) (one for each pump)
16) Pressure gauge
17) Starting pressure switches of main pumps
Starting pressure switch to stop jockey pump
18) Electric boxes (one for each pump)
19) Diaphragm tanks
20) Steel base for all pumps
All the butterfly valves or ball valve are locked in the normal position by means of a lock and key.
On request: anti-vibration couplings in both the suction and delivery sections.

52

619

AUE, AUD, AUED


UNI-EN 12845 fire-fighting systems
Construction

Hydraulic components

Units constructed in accordance with UNI-EN 12845 standards for


automatic fire-fighting systems (with sprinkler) and according to UNI
10779 for fire-fighting systems with fire hydrants.
The units may be composed of 1 or 2 main pumps.
Units are fitted with a jockey pump, with which the system pressure
level can be maintained without having to start the main pumps.

Each main pump is fitted with:


- Pressure and vacuum gauge in the suction section.
- Butterfly valve in the suction section (on request only for installation
with positive suction head).
- Pressure gauge in the delivery section.
- Adjusted diaphragm.
- Pressure switch to indicate the pump is operating.
- Non-return valve of the accessible swing-type.
- Butterfly valve in the delivery section.
- Manual test circuit with pressure switches, pressure gauge, nonreturn valve and ball valve and cylindrical 20-liter (15 bar) tank (one
for each pump).
The jockey pump is fitted with:
- Ball valve in the suction section (on request only if the pump has a
positive suction head).
- Non-return valve and ball valve in the delivery section.
- Manual test circuit with pressure switch, pressure gauge, non-return
valve and ball valve and cylindrical 20-liter (15 bar) tank (one for each
pump).
Other components:
- Delivery manifold.
- Coupling for connection of a priming tank (only for the pumps
installed with positive suction head).
- The suction manifold is never supplied as such execution is forbidden by the standards.
- The units with vertical multistage pumps and submersible borehole
pumps with pressure higher than 6-7 bar are fitted with an adjustable
safety valve to release the overpressure.

Application
For feeding water to automatic fire-fighting systems and units with
hydrants.

Operation
The pumps start operating after a fall in the pressure level in the fireextinguishing system.
The first pump to be triggered is the jockey pump.
If this pump cannot restore the pressure level, the main pump starts.
When there is more than one main pump, the pumps start in cascade
sequence, with the starting pressure switches set at different pressure levels.
The pressure switches of the main pumps are used only for starting,
as the pumps must be stopped manually for UNI-EN 12845 units or
automatically with a timer for UNI 10779 sets.
The recirculation diaphragm allows for operation of the main pumps
also when the delivery port is closed (with no consumption of water in
the system), avoiding overheating of the water inside the pump body.

On request:
- Manifold for flow meter.
- Adjusted-flange, diaphragm type, flow meter.

Electric boxes

Weekly test (on request)


The programmable clock in the electric box controls the forced starting
of the main pump (electric driven pump only).
The diaphragm avoids overheating of the water in the pump body.

Electric main-pump box (electric motor)


Each main pump has its own electric control board housed in a metal
cabinet with IP54 protection. The box contains the devices required
for operation and control of the pump.
Motor starting is direct for power ratings up to 7.5 kW.
For motors with a rating equal to or higher than 11 kW pump starting
is of the Y/ type with fuses, contactors and timer.
On request:
programmable clock for the weekly test.
Timer for pumps stop after 20 minutes (UNI 10779)
The following devices are located on the internal door panel:
- Line-sectioning handle - Voltmeter and ammeter with switch
- Manual-0-Automatic selector with extractible key only in
automatic position - Start/Stop pushbuttons - Pilot lights to indicate:
no-volt, pump running, voltage on.
Electric main-pump box (diesel motor)
This cabinet contains the electronic control devices for the control of
the diesel motor and the battery chargers for feeding the starter
accumulators.
The following devices are located on the front of the box:
- Line-sectioning handle.
- Front panel of the electronic unit.
- Manual-0-Automatic selector with extractible key only an automatic
position.
Electric jockey-pump box
When installed, the jockey pump is fitted with its own electric panel,
metal housing with IP 54 protection.
Control box (on request).
To be installed in a place to be looked after, to signal any possible
failure of the unit state. It must be connected to V.220 and it gives an
acoustic and visual signal for 24 hours.

Pumps
Main pumps
The main pumps can be :
N series: single stage horizontal centrifugal pumps
NMD series: centrifugal pumps with two impellers
MXV series: multistage vertical centrifugal pumps
SD-SDS- SDX series: submersible centrifugal borehole pumps
The N series centrifugal pumps are coupled with the electric or diesel
motor through a bearing coupling. This solution allows to operate on
the hydraulic part without moving the motor.
Jockey pump
Jockey pump can be a self-priming jet pump, a centrifugal pump with
two impellers, a vertical multistage pump or a submersible borehole
pump.
The maximum pressure developed by the jockey pump is always greater than the pressure of the main pumps.
Motors
Two-pole induction type, 50 Hz, n = 2,900 rpm
Three-phase 230/400V 10% up to 3 kW
400/690V 10% 4 kW and higher.
Insulation class F
Protection IP 54 for close coupled pumps, IP 55 for pumps with coupling and IP 68 for submersible borehole pumps.
Construction in accordance with: IEC 60034
Other voltage and frequency ratings available on request

Designation of units
.... 21 - 40/200A
Type of main pump
jockey pump
Number of main pumps
AUE UNI-EN 12845 unit with electric pump N
AUD UNI-EN 12845 unit with N series diesel pump
AUED UNI-EN 12845 unit with N series electric and diesel pump

Diesel motors (for standardised N-series pumps)


These are direct-injection pumps fitted with electric control box, fuel
tank, starter batteries and silencer.

620

Control panels
UNI-EN 12845 fire-fighting systems
Control panels
QTPAN 1,1-1,5-5,5 kW
Jockey pumps control panel

QTPAN 1D 2,25,5 kW
Main pump control panel
(D.O.L. starting)

L2

L2

L1

L3

QTPAN 1ST 5575 kW


Main pump control panel (Y/ starting)

L2

L1

L3

QTPAN 1ST 9,245 kW


Main pump control panel
(Y/ starting)

L1

L3

QANM 1
Main pump control panel (diesel motor)

QACR 11-21
Control panel for remote control

52

621

AUE
UNI-EN 12845 fire-fighting systems
With 1 electric pump
30
20

40

U.S. g.p.m.

50

30

40

50

100

Imp. g.p.m.

200
100

300
200

400
300

500
400

1000
500

1000

130

400

AUE 11
100
300

AUE 11 40/250

...11 65/250

...11 50/250

...11
100/250

...11 80/250

200

50

H
...11 40/200

AUE 11 32/200

40

...11 65/200

...11 50/200

ft

...11
80/200
...11 100/200

100
90

30
AUE 11 32/160

...11 40/160

...11 50/160

80

...11 65/160

...11 80/160

70

20

60
15

100

9 10
150

20

m 3/h
l/min

30

300

400

40

50

500

100
1000

50
300

200
2000

3000

4000

5000

72.860.3/2

With 2 electric pumps


60
40

80

U.S. g.p.m.

100

60

80

100

200

Imp. g.p.m.

400
200

600
400

1000

800
600

800

2000
1000

2000

130

400

AUE 21
100
300

AUE 21 40/250

...21 65/250

...21 50/250

...21
100/250

...21 80/250

200

50

H
...21 40/200

AUE 21 32/200

40

...21 65/200

...21 50/200

ft

...21
80/200
...21
100/200

100
90

30
AUE 21 32/160

...21 40/160

...21 50/160

80

...21
80/160

...21 65/160

70

20

60
15

20

10
200

300

40

m 3/h
l/min

600

60
800

80

1000

100

400

200
2000

4000

6000

50
600
8000 10000
72.860.4/2

622

AUE 11
UNI-EN 12845 units with 1 electric main pump
Performance
Unit designation
Power

Main pump
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE

11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11

32/160A/A
32/200C/A
32/200A/A
40/160B/A
40/160A/A
40/200D/A
40/200B/A
40/200A/A
40/250C/A
40/250B/A
40/250A/A
50/160B/A
50/160A/A
50/200B/A
50/200A/A
50/200S/A
50/250C/A
50/250B/A
50/250A/A
65/160B/B
65/160AR
65/160A/B
65/200C/A
65/200B/A
65/200A/A
65/250C/A
65/250B/A
65/250A/A
80/160B/B
80/160A/B
80/200B/A
80/200A/A
80/250E/A
80/250D/A
80/250C/A
80/250B/A
80/250A/A
100/200E/A
100/200D/A
100/200C/A
100/200B/A
100/200A/A
100/250B/A
100/250A/A

Jockey pump
NG 5/18E
NG 5/16E
NG 6/18E
NG 5/22E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/22E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 5/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18/A
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

kW
3 + 1,1
4 + 1,1
5,5 + 1,5
4 + 1,1
5,5 + 1,1
5,5 + 1,1
7,5 + 1,1
11 + 1,5
11 + 1,5
15 + 2,2
18,5 + 2,2
7,5 + 1,1
11 + 1,1
11 + 1,1
15 + 1,5
18,5 + 1,5
15 + 1,1
18,5 + 2,2
22 + 2,2
15 + 1,1
18,5 + 1,1
18,5 + 1,1
18,5 + 1,1
22 + 1,1
30 + 1,5
30 + 2,2
37 + 2,2
45 + 4
18,5 + 1,1
22 + 1,1
30 + 1,5
37 + 1,5
30 + 1,5
37 + 2,2
45 + 2,2
55 + 2,2
75 + 4
22 + 1,1
30 + 1,5
37 + 2,2
45 + 2,2
55 + 2,2
75 + 2,2
92 + 4

Average capacity
pump
m3/h
12
12
12
28,5
32
26,5
26,5
29
28,5
28,5
28,5
55,5
55,5
51
51
51
46,5
46,5
46,5
90
90
90
90
90
90
78
78
78
134
134
128
128
128
134
134
134
134
174
189
204
204
204
204
204

Pressure switch settings

Max. capacity
pump

m3/h

34
41
54,5
32,5
30
33
44
51
55
64,5
86
23
32
41,5
49
54,5
48,5
62
75
30
34
38
38,5
45,5
52
59
76
87
31
36
42
52
43
56
67
78
90
26
31
39
48
57
65
85

16,8
16,8
16,8
42
48
37,8
37,8
42
42
42
42
81
81
78
78
78
69
69
69
132
132
132
132
132
132
108
108
108
192
192
180
180
180
192
192
192
192
240
270
300
300
300
300
300

30
36
49
14
17
14
30,5
35
33,5
45
70,5
9,5
19
23
32,5
37
24,5
43
58,5
23
27
32
27
35
41,5
50
67
78
22
28
32
43
29
41
51
63
76
19
19
22
32
42
48
67

Main pump
bar
2,7
3,6
4,7
1,8
2,3
2,8
3,6
4,3
4,5
5,5
7,6
1,5
2,3
3,3
4
4,6
3,5
5
6,5
2,4
2,8
3,2
3,4
3,9
4,5
5,4
7
7,8
2,4
2,8
3,5
4,5
4,1
5,5
6,3
7,2
8,3
2
2,5
3,5
4,4
4,8
6
7,8

3,3
4,2
5,4
2,5
3
3,4
4,3
5
5,3
6,3
8,2
2,2
3
4
4,7
5,2
4,2
5,6
7,2
3
3,4
3,8
4
4,5
5,2
6
7,6
8,5
3
3,4
4,2
5,2
4,7
6,1
6,9
7,9
9
2,6
3,2
4,1
5
5,5
6,8
8,5

Jockey pump
bar
3
4
5
2,2
2,8
3,3
3,9
4,6
4,8
5,8
8
1,8
2,6
3,6
4,3
5
3,8
5,4
6,8
2,8
3,2
3,5
3,8
4,3
5
5,8
7,4
8,3
2,8
3,3
4
5
4,5
5,9
6,8
7,8
8,8
2,4
3
3,9
4,8
5,4
6,6
8,2

3,6
4,7
5,7
2,9
3,5
4
4,6
5,3
5,6
6,6
8,6
2,5
3,3
4,3
5
5,7
4,5
6
7,5
3,5
3,8
4,2
4,5
5
5,6
6,5
8
9
3,5
3,9
4,7
5,7
5,1
6,5
7,4
8,4
9,4
3
3,7
4,6
5,5
6
7,3
9

52

623

AUE 21
UNI-EN 12845 units with 2 electric main pumps
Performance
Unit designation
Power

Main pump
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE

21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21

32/160A/A
32/200C/A
32/200A/A
40/160B/A
40/160A/A
40/200D/A
40/200B/A
40/200A/A
40/250C/A
40/250B/A
40/250A/A
50/160B/A
50/160A/A
50/200B/A
50/200A/A
50/200S/A
50/250C/A
50/250B/A
50/250A/A
65/160B/B
65/160AR
65/160A/B
65/200C/A
65/200B/A
65/200A/A
65/250C/A
65/250B/A
65/250A/A
80/160B/B
80/160A/B
80/200B/A
80/200A/A
80/250E/A
80/250D/A
80/250C/A
80/250B/A
80/250A/A
100/200E/A
100/200D/A
100/200C/A
100/200B/A
100/200A/A
100/250B/A
100/250A/A

Jockey pump
NG 5/18E
NG 5/16E
NG 6/18E
NG 5/22E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/12E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 5/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18/A
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

kW
3 + 3 +1,1
4 + 4 + 1,1
5,5+5,5+1,5
4 + 4 + 1,1
5,5+5,5+1,1
5,5+5,5+1,1
7,5+7,5+1,1
11 + 11 + 1,5
11 + 11 + 1,5
15 + 15 + 2,2
18,5+18,5+2,2
7,5+7,5+1,1
11 + 11 + 1,1
11 + 11 + 1,1
15 + 15 + 1,5
18,5+18,5+1,5
15 + 15 + 1,1
18,5+18,5+2,2
22 + 22 + 2,2
15 + 15 + 1,1
18,5+18,5+1,1
18,5+18,5+1,1
18,5+18,5+1,1
22 + 22 + 1,1
30 + 30 + 1,5
30 + 30 + 2,2
37 + 37 + 2,2
45 + 45 + 4
18,5+18,5+1,1
22 + 22 + 1,1
30 + 30 + 1,5
37 + 37 + 1,5
30 + 30 + 1,5
37 + 37 + 2,2
45 + 45 + 2,2
55 + 55 + 2,2
75 + 75 + 4
22 + 22 + 1,1
30 + 30 + 1,5
37 + 37 + 2,2
45 + 45 + 2,2
55 + 55 + 2,2
75 + 75 + 2,2
92 + 92 + 4

Average capacity Max. capacity


of one pump
of one pump
m /h

m /h

12
12
12
28,5
32
26,5
26,5
29
28,5
28,5
28,5
55,5
55,5
51
51
51
46,5
46,5
46,5
90
90
90
90
90
90
78
78
78
134
134
128
128
128
134
134
134
134
174
189
204
204
204
204
204

34
41
54,5
32,5
30
31
44
51
55
64,5
86
23
32
41,5
49
54,5
48,5
62
75
30
34
38
38,5
45,5
52
59
76
87
31
36
42
52
43
56
67
78
90
26
31
39
48
57
65
85

16,8
16,8
16,8
42
48
37,8
37,8
42
42
42
42
81
81
78
78
78
69
69
69
132
132
132
132
132
132
108
108
108
192
192
180
180
180
192
192
192
192
240
270
300
300
300
300
300

30
36
49
14
17
14
30,5
35
33,5
45
70,5
9,5
19
23
32,5
37
24,5
43
58,5
23
27
32
27
35
41,5
50
67
78
22
28
32
43
29
41
51
63
76
19
19
22
32
42
48
67

624

Pressure switch settings


Main pump
1
bar
2,7
3,6
4,7
1,8
2,3
2,8
3,6
4,3
4,5
5,5
7,6
1,5
2,3
3,3
4
4,6
3,5
5
6,5
2,4
2,8
3,2
3,4
3,9
4,5
5,4
7
7,8
2,4
2,8
3,5
4,5
4,1
5,5
6,3
7,2
8,3
2
2,5
3,5
4,4
4,8
6
7,8

3,3
4,2
5,4
2,5
3
3,4
4,3
5
5,3
6,3
8,2
2,2
3
4
4,7
5,2
4,2
5,6
7,2
3
3,4
3,8
4
4,5
5,2
6
7,6
8,5
3
3,4
4,2
5,2
4,7
6,1
6,9
7,9
9
2,6
3,2
4,1
5
5,5
6,8
8,5

Main pump
2
bar
2,3
3,2
4,3
1,5
2
2,4
3,3
4
4,2
5,2
7,2
1,2
2
3
3,7
4,2
3,2
4,7
6,2
2
2,4
2,8
3
3,5
4,1
5
6,6
7,4
2
2,4
3,1
4,1
3,7
5,1
5,9
6,8
7,9
1,6
2,1
3,1
4
4,4
5,6
7,4

2,9
3,8
5
2,3
2,7
3
4
4,7
5,1
6,3
7,8
1,9
2,7
3,7
4,4
4,8
3,9
5,3
6,9
2,6
3
3,4
3,6
4,1
4,8
5,6
7,2
8,1
2,6
3
3,8
4,8
4,3
5,7
6,5
7,5
8,6
2,2
2,8
3,7
4,6
5,1
6,4
8,1

Jockey pump
bar
3
4
5
2,2
2,8
3,3
3,9
4,6
4,8
5,8
8
1,8
2,6
3,6
4,3
5
3,8
5,4
6,8
2,8
3,2
3,5
3,8
4,3
5
5,8
7,4
8,3
2,8
3,3
4
5
4,5
5,9
6,8
7,8
8,8
2,4
3
3,9
4,8
5,4
6,6
8,2

3,6
4,7
5,7
2,9
3,5
4
4,6
5,3
5,6
6,6
8,6
2,5
3,3
4,3
5
5,7
4,5
6
7,5
3,5
3,8
4,2
4,5
5
5,6
6,5
8
9
3,5
3,9
4,7
5,7
5,1
6,5
7,4
8,4
9,4
3
3,7
4,6
5,5
6
7,3
9

AUE 11
UNI-EN 12845 units with 1 electric main pump
Dimensions

A max

G max

DN2

DN1

DN3

3.93.131.1

B1

Unit designation
Main pump

Jockey pump

AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE

NG 5/18E
NG 5/16E
NG 6/18E
NG 5/22E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/22E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 5/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18/A
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11

32/160A/A
32/200C/A
32/200A/A
40/160B/A
40/160A/A
40/200D/A
40/200B/A
40/200A/A
40/250C/A
40/250B/A
40/250A/A
50/160B/A
50/160A/A
50/200B/A
50/200A/A
50/200S/A
50/250C/A
50/250B/A
50/250A/A
65/160B/B
65/160AR
65/160A/B
65/200C/A
65/200B/A
65/200A/A
65/250C/A
65/250B/A
65/250A/A
80/160B/B
80/160A/B
80/200B/A
80/200A/A
80/250E/A
80/250D/A
80/250C/A
80/250B/A
80/250A/A
100/200E/A
100/200D/A
100/200C/A
100/200B/A
100/200A/A
100/250B/A
100/250A/A

Dimensions
mm

Connections
DN 1

DN 2

DN 3

B1

50

G2

G 1 1/2

750

900

500

240

G2

G 1 1/2

750

900

500

317
345
360

1150
1200
1215

1500

50
65

65

G 1 1/2

800

900

500

240

317

1290

1530

65

65

G 1 1/2

800

950

500

240

360

1355

1600

65

65

G 1 1/2

800

950

500

240

380

1420

1660

65

80

G 1 1/2

850

950

550

240

360

1380

1615

65

80

G 1 1/2

850

1000

550

240

360

1400

1635

65

80

G 1 1/2

850

1000

550

835
855
915
835
855
855
915
1065
955
1060
1060
915
1065
955
1060
1060
1060
1060
1100

240

380

1445

1700

80

100

G 1 1/2

850

1000

550

240

360

1480

1700

80

100

G 1 1/2

850

1000

550

240

380

1525

1740

80

100

G 1 1/2

850

1050

550

240

410

1580

1795

100

125

G 1 1/2

950

1000

550

250

380

1640

1840

100

125

G 1 1/2

950

1000

550

1050

550

100

125

G 1 1/2

950
950
950
950
1050

125

150

G 1 1/2

1300

1200

700

125

150

G 1 1/2

1300

1200
1300

700

625

1060
1100
1140
1140
1275
1375
1375
1100
1140
1275
1375
1275
1375
1375
1415
1530
1250
1275
1375
1375
1415
1530
1620

240

250

250

260

260

1500

380

1675

1875

410
410
410
485
515
410
410
410
410
485
515
605

1725
1725
1725
1800
1830
1805
1805
1805
1805
1880
1910
2000

1925
1925
1925
2000
2030
1990
1990
1990
1990
2065
2095
2185

52

AUE 21
UNI-EN 12845 units with 2 electric main pumps
Dimensions

A max

DN1

G max

DN2

DN1

DN3

B1

3.93.131.2

B1
B

Unit designation
Main pump

Jockey pump

AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE
AUE

NG 5/18E
NG 5/16E
NG 6/18E
NG 5/22E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/22E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 5/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18E
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21

32/160A/A
32/200C/A
32/200A/A
40/160B/A
40/160A/A
40/200D/A
40/200B/A
40/200A/A
40/250C/A
40/250B/A
40/250A/A
50/160B/A
50/160A/A
50/200B/A
50/200A/A
50/200S/A
50/250C/A
50/250B/A
50/250A/A
65/160B/B
65/160AR
65/160A/B
65/200C/A
65/200B/A
65/200A/A
65/250C/A
65/250B/A
65/250A/A
80/160B/B
80/160A/B
80/200B/A
80/200A/A
80/250E/A
80/250D/A
80/250C/A
80/250B/A
80/250A/A
100/200E/A
100/200D/A
100/200C/A
100/200B/A
100/200A/A
100/250B/A
100/250A/A

Dimensions
mm

Connections
DN 1

DN 2

DN 3

B1

50

65

G 1 1/2

1200

1350

450

240

65

G 1 1/2

1200

1350

450

317
345
360

1160
1210
1225

1500

50
65

80

G 1 1/2

1200

1350

450

240

317

1295

1530

65

80

G 1 1/2

1200

1350

450

240

360

1360

1600

65

80

G 1 1/2

1200

1550

450

835
855
915
835
855
855
915
915
955
1060
1060

240

380

1425

1660

65

100

G 1 1/2

1400

1500

550

240

360

1395

1615

240

360

1415

1635

240

380

1460

1700

240

360

1495

1700

240

380

1540

1740

240

410

1595

1795

250

380

1655

1840

250

380

1690

1875

410
410
410
485
515
410
410
410
410
485
515
665

1740
1740
1740
1815
1845
1830
1830
1830
1830
1905
1935
2155

1925
1925
1925
2000
2030
1990
1990
1990
1990
2065
2095
2325

65

100

G 1 1/2

1400

1500

550

65

100

G 1 1/2

1400

1550

550

80

125

G 1 1/2

1500

1550

550

80

125

G 1 1/2

1500

1550

550

80

125

G 1 1/2

1500

1550

550

100

150

G 1 1/2

1500

1550

550

100

150

G 1 1/2

1500

1550

550

100

150

G 1 1/2

1500

1800

550

125

200

G 1 1/2

1500

1800

550

125

200

G 1 1/2

1500

1800

550

626

915
955
1060
1060
1060
1060
1100
1060
1100
1140
1140
1275
1375
1375
1100
1140
1275
1375
1275
1375
1275
1415
1530
1250
1275
1375
1375
1415
1530
1620

240

250

260

260

1500

AUD - AUED
UNI-EN 12845 fire-fighting systems
With 1 pump (diesel motor)
30
20

40

U.S. g.p.m.

50

30

40

50

100

Imp. g.p.m.

200
100

300
200

400
300

500

1000

400

500

1000

130

400

AUD 11
100
300

AUD 11 40/250

...11 80/250

...11 65/250

...11 100/250

...11 50/250

200

50
...11 40/200

AUD 11 32/200

40

...11 65/200

...11 50/200

...11
80/200

ft
...11 100/200
100
90

30
AUD 11 32/160

...11 40/160

...11 50/160

80

...11 65/160

...11 80/160

70

20

60
15

100

9 10
150

20

m 3/h
l/min

30

300

400

40

50

500

100
1000

50
300

200
2000

3000

4000

5000

72.860.3/2

With 2 pumps (electric and diesel motors)


60
40

80

U.S. g.p.m.

100

60

80

100

200

Imp. g.p.m.

400
200

600
400

800

1000
800

600

2000
1000

2000

130

400

AUED 21
100
300

AUED 21 40/250

...21 65/250

...21 50/250

...21 80/250

...21 100/250
200

50

H
...21 40/200

AUED 21 32/200

40

...21 65/200

...21 50/200

ft

...21
80/200
...21 100/200

100
90

30
AUED 21 32/160

...21 40/160

...21 50/160
...21 65/160

80

...21 80/160

70

20

60
15

20

10
200

300

40

m 3/h
l/min

600

60
800

80

1000

100

400

200
2000

4000

6000

50
600
8000 10000
72.860.4/2

627

52

AUD 11
UNI-EN 12845 units with 1 main pump (diesel motor)
Performance
Unit designation
Power

Main pump
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD

11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11

32/160A/A
32/200C/A
32/200A/A
40/160B/A
40/160A/A
40/200D/A
40/200B/A
40/200A/A
40/250C/A
40/250B/A
40/250A/A
50/160B/A
50/160A/A
50/200B/A
50/200A/A
50/200S/A
50/250C/A
50/250B/A
50/250A/A
65/160B/B
65/160AR
65/160A/B
65/200C/A
65/200B/A
65/200A/A
65/250C/A
65/250B/A
65/250A/A
80/160B/B
80/160A/B
80/200B/A
80/200A/A
80/250E/A
80/250D/A
80/250C/A
80/250B/A
80/250A/A
100/200E/A
100/200D/A
100/200C/A
100/200B/A
100/200A/A
100/250B/A
100/250A/A

Jockey pump
NG 5/16E
NG 5/18E
NG 5/22E
NG 6/18E
NG 6/22E
NG 7/16E
NG 7/18E
NMD 25/190AE

Jockey pump
NG 5/18E
NG 5/16E
NG 6/18E
NG 5/12E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/22E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 5/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18/A
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18E
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

kW
1,1
1,1
1,1
1,5
1,5
2,2
2,2
4

Average capacity
pump
m3/h

kW
4,2 / 2900
4,2 / 2900
6,1 / 2900
4,2 / 2900
6,1 / 2900
6,1 / 2900
6,8 / 2900
10,5 / 2900
10,5 / 2900
17,5 / 2900
26,2 / 2900
6,1 / 2900
10,5 / 2900
10,5 / 2900
17,5 / 2900
17,5 / 2900
17,5 / 2900
26,2 / 2900
26,2 / 2900
17,5 / 2900
26,2 / 2900
26,2 / 2900
26,2 / 2900
26,2 / 2900
32,5 / 2900
32,5 / 2900
48 / 2900
48 / 2900
17,5 / 2900
26,2 / 2900
26,2 / 2900
32,5 / 2900
26,2 / 2900
32,5 / 2900
48 / 2900
61 / 2900
61 / 2900
26,2 / 2900
26,2 / 2900
32,5 / 2900
48 / 2900
61 / 2900
61 / 2900
93,5 / 2900

Diesel motors
15LD350
15LD440
15LD500
25LD425-2
9LD625-2
11LD625-3
D703L.F30
D703LT.F30
D704LT.F30
D706LT.F30

12
12
12
28,5
32
26,5
26,5
29
28,5
28,5
28,5
55,5
55,5
51
51
51
46,5
46,5
46,5
90
90
90
90
90
90
78
78
78
134
134
128
128
128
134
134
134
134
174
189
204
204
204
204
204

kW*
4,2
6,1
6,8
10,5
17,5
26,2
32,5
48
61
93,5

Pressure switch settings

Max. capacity
pump

m3/h

34
41
54,5
32,5
30
31
44
51
55
64,5
86
23
32
41,5
49
54,5
48,5
62
75
30
36
38
38,5
45,5
52
59
76
87
31
36
42
52
43
60
67
78
90
26
31
39
48
57
65
85

16,8
16,8
16,8
42
48
37,8
37,8
42
42
42
42
81
81
78
78
78
69
69
69
132
132
132
132
132
132
108
108
108
192
192
180
180
180
192
192
192
192
240
270
300
300
300
300
300

30
36
49
14
17
14
30,5
35
33,5
45
70,5
9,5
19
23
32,5
37
24,5
43
58,5
23
27
32
27
35
41,5
50
67
78
22
28
32
43
29
41
51
63
76
19
19
22
32
42
48
67

Main pump
bar
2,7
3,6
4,7
1,8
2,3
2,8
3,6
4,3
4,5
5,5
7,6
1,5
2,3
3,3
4
4,6
3,5
5
6,5
2,4
2,8
3,2
3,4
3,9
4,5
5,4
7
7,8
2,4
2,8
3,5
4,5
4,1
5,5
6,3
7,2
8,3
2
2,5
3,5
4,4
4,8
6
7,8

* Continuous rating overloading capacity, NA curve.

628

3,3
4,2
5,4
2,5
3
3,4
4,3
5
5,3
6,3
8,2
2,2
3
4
4,7
5,2
4,2
5,6
7,2
3
3,4
3,8
4
4,5
5,2
6
7,6
8,5
3
3,4
4,2
5,2
4,7
6,1
6,9
7,9
9
2,6
3,2
4,1
5
5,5
6,8
8,5

Jockey pump
bar
3
4
5
2,2
2,8
3,3
3,9
4,6
4,8
5,8
8
1,8
2,6
3,6
4,3
5
3,8
5,4
6,8
2,8
3,2
3,6
3,8
4,3
5
5,8
7,4
8,3
2,8
3,3
4
5
4,5
5,9
6,8
7,8
8,8
2,4
3
3,9
4,8
5,4
6,6
8,2

3,6
4,7
5,7
2,9
3,5
4
4,6
5,3
5,6
6,6
8,6
2,5
3,3
4,3
5
5,7
4,5
6
7,5
3,5
3,8
4,2
4,5
5
5,6
6,5
8
9
3,5
3,9
4,7
5,7
5,1
6,5
7,4
8,4
9,4
3
3,7
4,6
5,5
6
7,3
9

AUED 21
UNI-EN 12845 units with 2 main pumps (electric and diesel motors)
Performance
Motors power

Unit designation

electric
Pumps
Electric
diesel
AUED 21 - 32/160A/A - 32/160A/A
AUED 21 - 32/200C/A - 32/200C/A
AUED 21 - 32/200A/A - 32/200A/A
AUED 21 - 40/160B/A - 40/160B/A
AUED 21 - 40/160A/A - 40/160A/A
AUED 21 - 40/200D/A - 40/200D/A
AUED 21 - 40/200B/A - 40/200B/A
AUED 21 - 40/200A/A - 40/200A/A
AUED 21 - 40/250C/A - 40/250C/A
AUED 21 - 40/250B/A - 40/250B/A
AUED 21 - 40/250A/A - 40/250A/A
AUED 21 - 50/160B/A - 50/160B/A
AUED 21 - 50/160A/A - 50/160A/A
AUED 21 - 50/200B/A - 50/200B/A
AUED 21 - 50/200A/A - 50/200A/A
AUED 21 - 50/200S/A - 50/200S/A
AUED 21 - 50/250C/A - 50/250C/A
AUED 21 - 50/250B/A - 50/250B/A
AUED 21 - 50/250A/A - 50/250A/A
AUED 21 - 65/160B/B - 65/160B/B
AUED 21 - 65/160AR - 65/160AR
AUED 21 - 65/160A/B - 65/160A/B
AUED 21 - 65/200C/A - 65/200C/A
AUED 21 - 65/200B/A - 65/200B/A
AUED 21 - 65/200A/A - 65/200A/A
AUED 21 - 65/250C/A - 65/250C/A
AUED 21 - 65/250B/A - 65/250B/A
AUED 21 - 65/250A/A - 65/250A/A
AUED 21 - 80/160B/B - 80/160B/B
AUED 21 - 80/160A/B - 80/160A/B
AUED 21 - 80/200B/A - 80/200B/A
AUED 21 - 80/200A/A - 80/200A/A
AUED 21 - 80/250E/A - 80/250E/A
AUED 21 - 80/250D/A - 80/250D/A
AUED 21 - 80/250C/A - 80/250C/A
AUED 21 - 80/250B/A - 80/250B/A
AUED 21 - 80/250A/A - 80/250A/A
AUED 21 - 100/200E/A - 100/200E/A
AUED 21 - 100/200D/A - 100/200D/A
AUED 21 - 100/200C/A - 100/200C/A
AUED 21 - 100/200B/A - 100/200B/A
AUED 21 - 100/200A/A - 100/200A/A
AUED 21 - 100/250B/A - 100/250B/A
AUED 21 - 100/250A/A - 100/250A/A

Jockey pump
NG 5/16E
NG 5/18E
NG 5/22E
NG 6/18E
NG 6/22E
NG 7/16E
NG 7/18E
NMD 25/190AE

kW
1,1
1,1
1,1
1,5
1,5
2,2
2,2
4

Jockey pump

kW

NG 5/18E
NG 5/16E
NG 6/18E
NG 5/22E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/22E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 5/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18/A
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

3
4
5,5
4
5,5
5,5
7,5
11
11
15
18,5
7,5
11
11
15
18,5
15
18,5
22
15
18,5
18,5
18,5
22
30
30
37
45
18,5
22
30
37
30
37
45
55
75
22
30
37
45
55
75
92

Diesel motors
15LD350
15LD440
15LD500
25LD425-2
9LD625-2
11LD625-3
D703L.F30
D703LT.F30
D704LT.F30
D706LT.F30

Average capacity Max. capacity


of one pump
of one pump

diesel
kW / giri-rpm

m /h

m /h

4,2
4,2
6,1
4,2
6,1
6,1
6,8
10,5
10,5
17,5
26,2
6,1
10,5
10,5
17,5
17,5
17,5
26,2
26,2
17,5
26,2
26,2
26,2
26,2
32,5
32,5
48
48
17,5
26,2
26,2
32,5
26,2
32,5
48
61
61
26,2
26,2
32,5
48
61
61
93,5

12
12
12
28,5
32
26,5
26,5
29
28,5
28,5
28,5
55,5
55,5
51
51
51
46,5
46,5
46,5
90
90
90
90
90
90
78
78
78
134
134
128
128
128
134
134
134
134
174
189
204
204
204
204
204

34
41
54,5
32,5
30
31
44
51
55
64,5
86
23
32
41,5
49
49
48,5
62
75
30
36
38
38,5
45,5
52
59
76
87
31
36
42
52
43
56
67
78
90
26
31
39
48
57
65
85

16,8
16,8
16,8
42
48
37,8
37,8
42
42
42
42
81
81
78
78
78
69
69
69
132
132
132
132
132
132
108
108
108
192
192
180
180
180
192
192
192
192
240
270
300
300
300
300
300

30
36
49
14
17
14
30,5
35
33,5
45
70,5
9,5
19
23
32,5
32,5
24,5
43
58,5
23
27
32
27
35
41,5
50
67
78
22
28
32
43
29
41
51
63
76
19
19
22
32
42
48
67

/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/

kW*
4,2
6,1
6,8
10,5
17,5
26,2
32,5
48
61
93,5

2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2900
2600
2900
2900
2900

Pressure switch settings


Pump
1
bar
2,7
3,6
4,7
1,8
2,3
2,8
3,6
4,3
4,5
5,5
7,6
1,5
2,3
3,3
4
4
3,5
5
6,5
2,4
2,8
3,2
3,4
3,9
4,5
5,4
7
7,8
2,4
2,8
3,5
4,5
4,1
5,5
6,3
7,2
8,3
2
2,5
3,5
4,4
4,8
6
7,8

3,3
4,2
5,4
2,5
3
3,4
4,3
5
5,3
6,3
8,2
2,2
3
4
4,7
4,7
4,2
5,6
7,2
3
3,4
3,8
4
4,5
5,2
6
7,6
8,5
3
3,4
4,2
5,2
4,7
6,1
6,9
7,9
9
2,6
3,2
4,1
5
5,5
6,8
8,5

Pump
2
bar
2,3
3,2
4,3
1,5
2
2,4
3,3
4
4,2
5,2
7,2
1,2
2
3
3,7
3,7
3,2
4,7
6,2
2
2,4
2,8
3
3,5
4,1
5
6,6
7,4
2
2,4
3,1
4,1
3,7
5,1
5,9
6,8
7,9
1,6
2,1
3,1
4
4,4
5,6
7,4

2,9
3,8
5
2,3
2,7
3
4
4,7
5,1
6
7,8
1,9
2,7
3,7
4,4
4,4
3,9
5,3
6,9
2,6
3
3,4
3,6
4,1
4,8
5,6
7,2
8,1
2,6
3
3,8
4,8
4,3
5,7
6,5
7,5
8,6
2,2
2,8
3,7
4,6
5,1
6,4
8,1

Jockey pump
bar
3
4
5
2,2
2,8
3,3
3,9
4,6
4,8
5,8
8
1,8
2,6
3,6
4,3
4,3
3,8
5,4
6,8
2,8
3,2
3,6
3,8
4,3
5
5,8
7,4
8,3
2,8
3,3
4
5
4,5
5,9
6,8
7,8
8,8
2,4
3
3,9
4,8
5,4
6,6
8,2

3,6
4,7
5,7
2,9
3,5
4
4,6
5,3
5,6
6,6
8,6
2,5
3,3
4,3
5
5
4,5
6
7,5
3,5
3,8
4,2
4,5
5
5,6
6,5
8
9
3,5
3,9
4,7
5,7
5,1
6,5
7,4
8,4
9,4
3
3,7
4,6
5,5
6
7,3
9

* Continuous rating overloading capacity, NA curve.

52

629

AUD 11
UNI-EN 12845 units with 1 main pump (diesel motor)
A max

Dimensions

DN2

DN1

DN3

3.93.131.3

B1

Unit designation
Main pump
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD
AUD

11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11

32/160A/A
32/200C/A
32/200A/A
40/160B/A
40/160A/A
40/200D/A
40/200B/A
40/200A/A
40/250C/A
40/250B/A
40/250A/A
50/160B/A
50/160A/A
50/200B/A
50/200A/A
50/200S/A
50/250C/A
50/250B/A
50/250A/A
65/160B/B
65/160AR
65/160A/B
65/200C/A
65/200B/A
65/200A/A
65/250C/A
65/250B/A
65/250A/A
80/160B/B
80/160A/B
80/200B/A
80/200A/A
80/250E/A
80/250D/A
80/250C/A
80/250B/A
80/250A/A
100/200E/A
100/200D/A
100/200C/A
100/200B/A
100/200A/A
100/250B/A
100/250A/A

Dimensions
mm

Connections
Jockey pump
NG 5/18E
NG 5/16E
NG 6/18E
NG 5/22E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/22E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 5/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18/A
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

DN 1

DN 2

DN 3

B1

50

G2

G 1 1/2

1150

1000

500

900

240

532

1470

1695

50

G2

G 1 1/2

1150

1000

500

950

240

560

1520

1745

1200

1000
1050

500

950

240

532

1620

1860

560
570
570
590
605
605

1670
1680
1680
1745
1760
1760

1910
1920
1920
1985
2000
2000

570

1720

1955

570
585
585
605
605
625

1740
1755
1755
1800
1800
1820

1975
1990
1990
2035
2035
2055

585

1840

2055

605
625
625
645
665
665
605
625
645
665
645
665
665
665
665
645
645
665
665
665
690
735

1885
1905
1905
1950
1970
1970
2035
2055
2110
2130
2130
2150
2150
2150
2150
2220
2220
2240
2240
2240
2265
2310

2100
2120
2120
2165
2185
2185
2235
2255
2310
2330
2330
2350
2350
2350
2350
2405
2405
2425
2425
2425
2450
2495

65

65

G 1 1/2

65

65

G 1 1/2

1200

1050

500

1000

240

65

65

G 1 1/2

1200

1050

500

1200

240

65

80

G 1 1/2

1250

1050

550

1000

240

65

80

G 1 1/2

1250

1050

550

1200

240

65

80

G 1 1/2

1250

1050

550

1200
1200
1400

240

80

100

G 1 1/2

1300

1200

550

1200

240

80

100

G 1 1/2

1300

1200

550

1400

240

80

100

G 1 1/2

1300

1200

550

1500
1750
1750

240

100

125

G 1 1/2

1300

1200

550

1500

250

550

1700

250

100

125

G 1 1/2

1300

100

125

G 1 1/2

1300

125

150

G 1 1/2

1500

125

150

G 1 1/2

1500

630

1200
1250
1200
1250
1250
1350
1250
1250
1250
1250
1250
1300
1250
1350

550

700

700

1500
1750
1750
1750
1750
1500
1500
1750
1750
1750
1750
1900

250

260

260

AUED 21
UNI-EN 12845 units with 2 main pumps (electric and diesel motor)
A max

Dimensions

DN2

DN1

DN1

DN3

3.93.131.4

B1

B1
B

Unit designation
Main
pump
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED
AUED

Electric
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21
21

Dimensions
mm

Connections
Diesel

32/160A/A - 32/160A/A
32/200C/A - 32/200C/A
32/200A/A - 32/200A/A
40/160B/A - 40/160B/A
40/160A/A - 40/160A/A
40/200D/A - 40/200D/A
40/200B/A - 40/200B/A
40/200A/A - 40/200A/A
40/250C/A - 40/250C/A
40/250B/A - 40/250B/A
40/250A/A - 40/250A/A
50/160B/A - 50/160B/A
50/160A/A - 50/160A/A
50/200B/A - 50/200B/A
50/200A/A - 50/200A/A
50/200S/A - 50/200S/A
50/250C/A - 50/250C/A
50/250B/A - 50/250B/A
50/250A/A - 50/250A/A
65/160B/B - 65/160B/B
65/160AR - 65/160AR
65/160A/B - 65/160A/B
65/200C/A - 65/200C/A
65/200B/A - 65/200B/A
65/200A/A - 65/200A/A
65/250C/A - 65/250C/A
65/250B/A - 65/250B/A
65/250A/A - 65/250A/A
80/160B/B - 80/160B/B
80/160A/B - 80/160A/B
80/200B/A - 80/200B/A
80/200A/A - 80/200A/A
80/250E/A - 80/250E/A
80/250D/A - 80/250D/A
80/250C/A - 80/250C/A
80/250B/A - 80/250B/A
80/250A/A - 80/250A/A
100/200E/A - 100/200E/A
100/200D/A - 100/200D/A
100/200C/A - 100/200C/A
100/200B/A - 100/200B/A
100/200A/A - 100/200A/A
100/250B/A - 100/250B/A
100/250A/A - 100/250A/A

Jockey pump
NG 5/18E
NG 5/16E
NG 6/18E
NG 5/22E
NG 5/18E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 5/22E
NG 5/18E
NG 5/16E
NG 6/18E
NG 6/18E
NG 6/16E
NG 7/18/A
NG 7/16/A
NG 5/18E
NG 5/18E
NG 5/18E
NG 5/16E
NG 5/16E
NG 6/18E
NG 7/18/A
NG 7/16/A
NMD 25/190A/A
NG 5/18E
NG 5/18E
NG 6/18E
NG 6/18E
NG 6/18E
NG 7/18/A
NG 7/16/A
NG 7/16/A
NMD 25/190A/A
NG 5/22E
NG 6/22E
NG 7/22/A
NG 7/18/A
NG 7/18/A
NG 7/16/A
NMD 25/190A/A

DN 1

DN 2

DN 3

B1

50

65

G 1 1/2

1450

1400

450

900

240

532

1480

1695

50

65

G 1 1/2

1450

1400

450

950

240

560

1530

1745

1500

1400
1450

450

950

240

532

1625

1860

240

560
570
570
590
605
605

1675
1685
1685
1750
1765
1765

1910
1920
1920
1985
2000
2000

570

1745

1955

570
585
585
605
605
625

1755
1770
1770
1815
1815
1835

1975
1990
1990
2035
2035
2055

585

1855

2055

605
625
625
645
665
665
605
625
645
665
645
665
665
665
665
645
645
665
665
665
690
735

1900
1920
1920
1965
1985
1985
2050
2070
2125
2145
2145
2165
2165
2165
2165
2245
2245
2265
2265
2265
2290
2335

2100
2120
2120
2165
2185
2185
2235
2255
2310
2330
2330
2350
2350
2350
2350
2405
2405
2425
2425
2425
2450
2495

65

80

G 1 1/2

65

80

G 1 1/2

1500

1450

450

1000
1000
1150

65

80

G 1 1/2

1500

1450

450

1200

240

65

100

G 1 1/2

1700

1600

550

1000
1150

240

65

100

G 1 1/2

1700

1600

550

1200

240

65

100

G 1 1/2

1700

1600

550

1200
1200
1400

240

80

125

G 1 1/2

1800

1750

550

1200

240

80

125

G 1 1/2

1800

1750

550

1400

240

80

125

G 1 1/2

1800

1750

550

1500
1750
1750

240

100

150

G 1 1/2

1800

1750

550

1500

250

100

150

G 1 1/2

1800

1800

550

1700

250

550

100

150

G 1 1/2

1800

1750
1800
1800
1900
1800

125

200

G 1 1/2

2150

1850

700

125

200

G 1 1/2

2150

2200

700

631

1500
1750
1750
1750
1750
1500
1500
1700
1700
1700
1750
1900

250

260

260

52

AUE, AUD, AUED


UNI-EN 12845 fire-fighting systems

Characteristics of full-jet nozzles


Capacity

Water-jet range

Pressure
10
bar
3
4
5
6
7
8

115
130
150
160
175
185

Nozzle diameter mm
12
16
Flow-rate l/min
165
295
190
340
215
380
235
415
250
450
270
480

Pressure
20
bar
3
5
8

460
530
590
650
700
750

Characteristics of sprinkler nozzles


Capacity
Pressure

bar
2
3
4
5
6
7
8
9

Rated diameter of orifice


mm
10
15
20
Flow-rate l/min
80
98
114
127
139
150
161
171

113
139
160
180
196
214
226
240

Nozzle diameter mm
12
16
20
Range m
10 a 20 11 a 22 15 a 30 16 a 33
11 a 23 11 a 25 17 a 33 18 a 36
12 a 26 12 a 30 19 a 36 20 a 40
10

162
199
230
258
282
305
325
345

632

09/2016

QM, QT
Control panels

53
633

Index
Application

1~
QM
M COMP
PFC-M
QML 1 FT

T COMP
PFC-T
QTL 1 FT
QTL 1 D FTE
QTL 1 ST FT
QTL 1 ST FTE
QTL 1 SS E
QTL 1 IS FTE
QML 2 D

QTL 2 FT
QTL 2 ST FT
QML 3 FT

QTL 3 FT
QTL 3 ST FT
QTL 4 D FT
QTL 4 ST FT
QML 1 VFT

QTL 1 VFT
QML 2 VFT

QTL 2 VFT
QML 1.1 VFT

3~

QTL 3 VFT
QTL 1.2 VFT
QTL 4 VFT
QTL 1.3 VFT
QMLD 1D

QTLD 1D
QTLD 1ST FT
QMLD 2D
QTLD 2D
QTLD 2ST FT
QTLD 3D FT-RL
QTLD 3 ST-RL

QTL 1.1 VFT


QML 3 VFT

634

Bore-hole

TYPE

Surface

No. pumps

Submersible

Supply

0,3 1,5
0,37 2,2
0,37 2,2
0,37 2,2
0,37 7,5
0,37 5,5
0,37 11
4 30
5,5 45
5,5 110
7,5 132
5,5 110
0,37 1,5
0,37 5,5
5,5 45
0,37 2,2
0,37 5,5
5,5 4,5
0,37 5,5
5,5 45

0,4 7,5
0,37 3,7
0,4 7,5
0,37 3,7
0,4 75
0,37 3,7
0,4 75
0,4 75
0,4 75
0,4 75

0,25 1,1
4 92
0,25 1,1
0,25 1,1
4 92
0,55 5,5
4 92

Electronic

Electromechanical

Impedance stator

Soft start

Typology

Y/

D.O.L.

Starting

0,37 3,7

0,25 1,1

Variable speed

kW

Rotation speed

Fixed Speed

Power

page
636
637

637
638
638

639
639
640

640
641

641
642

643

647

653

643
644
644
645
645
646
646

647
648
648
649
649
650
650
651
651
652

653
654
655
655
656
657
657

53
635

Control panels
QM Control panel for 1 single-phase submersible pump

Code

Type

44017940000
44017960000
44017950000
44017990000

QM 6,3
QM 20
QM 25
QM 30

Capacitor

Motor 230V - 1~

Dimensions

450Vc

kW

HxBxP mm

6,3 F
20 F
25 F
30 F

0,3
0,55 - 0,75
0,9 -1,1
0,9 -1,1

200x75x76
200x75x76
200x75x76
200x75x76

Construction

Components

Control panel with ON-OFF switch and capacitor, for 1 submersible


pump with single-phase motor without built-in capacitor.

- Enclosure in thermoplastic material


- ON-OFF switch with lamp
- Capacitor
- Terminal board
- Cable glands

Technical data
- Mains single-phase 230V 10% 50/60 Hz
(other voltages on request).

- Ambient temperature from -5 C to +40 C.


- Protection IP 55.

QM Control panel with circuit breaker for 1 single-phase submersible pump

Code

Type

QM 4-16
QM 5-20
QM 5-25
QM 6-20
QM 7-25
QM 7-30
QM 8-25
QM 8-30
QM 10-40
QM 12-35

Protector

Capacitor

Motor 230V - 1~

Dimensions

max A

450Vc

kW

HxBxP mm

4
5
5
6
7
7
8
8
10
12

16 F
20 F
25 F
20 F
25 F
30 F
25 F
30 F
40 F
35 F

0,37
0,55
0,55
0,75
0,9
0,75
1,1
1,1
1,1
1,5

200x75x76
200x75x76
200x75x76
200x75x76
200x75x76
200x75x76
200x75x76
200x75x76
200x75x76
200x75x76

Construction

Components

Control panel with ON-OFF switch, circuit breaker and capacitor, for 1
submersible pump with single-phase motor without built-in capacitor.

- Enclosure in thermoplastic material


- ON-OFF switch with lamp
- Thermal device
- Capacitor
- Terminal board
- Cable glands

Technical data
- Mains single-phase 230V 10% 50/60 Hz
(other voltages on request).

- Ambient temperature from -5 C to +40 C.


- Protection IP 55.

636

Control panels
M COMP Control panel for 1 single-phase submersible pump
Code

LVBT

44020000000
44020001000
44020010000
44020011000
44020021000
44020023000
44020031000
44020032000
44020040000
44020041000
44020052000
44020053000
44020060000
44020062000
44020081000

Type

Protector

Capacitor

Motor 230V - 1~

max A

450Vc

kW

HxBxP mm

4,5
4,5
5
5
6
6
7
7
8
8
10
10
12
12
12
16

16 F
20 F
20 F
25 F
20 F
35 F
25 F
30 F
25 F
30 F
35 F
40 F
35 F
50 F
60 F
70 F

0,37
0,55
0,55
0,55
0,75
0,9
0,9
0,9
1,1
1,1
1,1
1,1
1,5
1,5
1,5
2,2

220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110

M COMP 4-16
M COMP 4-20
M COMP 5-20
M COMP 5-25
M COMP 6-20
M COMP 6-35
M COMP 7-25
M COMP 7-30
M COMP 8-25
M COMP 8-30
M COMP 10-35
M COMP 10-40
M COMP 12-35
M COMP 12-50
M COMP 12-60
M COMP 16-70

Construction

Components

Control panel with ON-OFF switch and capacitor for 1 submersible pump
with single-phase motor.
Suitable for use with LVBT board for level control.
Protection is provided by means of a main bi-polar switch with a phase.
protected against overload by means of a thermal element.

Technical data

- Enclosure in thermoplastic material.


- ON-OFF switch with pilot lamp with thermal protector.
- Capacitor.
- Terminal board.
- Terminals for LVBT board for level control.
- In/Out cable glands.
- Power relay (for M COMP 18 only)

- Mains single-phase 230V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

On request:

- Control through pressure switch (pressure booster set).


- Control through float switch (for filling a tank).

Dimensions

- LVBT card for level control.

PFC-M Power Factor Control Control panel for 1 submersible pump with single-phase motor, PF control
Type

Setting

Capacitor

450Vc

kW

PFC-M 18-16
PFC-M 18-20
PFC-M 18-25
PFC-M 18-30
PFC-M 18-35
PFC-M 18-40
PFC-M 18-50
PFC-M 18-60
PFC-M 18-70

1 - 18
1 - 18
1 - 18
1 - 18
1 - 18
1 - 18
1 - 18
1 - 18
1 - 18

16 F
20 F
25 F
30 F
35 F
40 F
50 F
60 F
70 F

0,37
0,55
0,55
0,75
0,75
1,1
1,5
1,5
2,2

Motor 50/60Hz

Dimensions

220V-240V - 1~

HxBxP mm
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110
220x210x110

Construction

Setting

Control panel for controlling one submersible pump with single-phase


motor. Electronic control of the operation and dry-running protection
through the power factor (PF) control.
The installation of level probes into the well is not required.
It stops the pump in case of lack of air cushion in the pressure vessel
(patented system).
Displayed operating data and alarms available in four languages.

- Min Max voltage range.


- Motor rated current.
- Power factor (PF) value for dry-running protection.
- Up to four programmable restarts in case of no water condition.

Technical data
- Mains single-phase 220-240V, 50/60 Hz.
- Max output current: 18 A.
- Ambient temperature from -5 C to +40 C.
- Relative humidity: from 20% to 90% without condensation
- Protection IP 55.
- Control through pressure switch (pressure booster set).
- Control through float switch (for filling a tank).
- Alarm output signal.
- Constructed in accordance with: IEC/EN 60439-1.

Alarms (with pump stop)


- Mains failure.
- Undervoltage and overvoltage.
- Motor overload.
- No water.
- No air cushion in the pressure vessel.

Components
- Enclosure in thermoplastic material. - Capacitor. - Terminal board.
- Display : 2x16 characters. - 6 button key board.
- In/Out Cable glands.

On request:
637

- RA 100 control panel for remote alarm.

53

Control panels
QML 1 FT Control panel for 1 pump with single-phase motor, direct starting

Code

---

Type

Dimensions

Motor 230V - 1~

Setting

kW

HxBxP mm

0,37
0,45 - 0,55
0,75
1,1
1,5

1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12

200x255x170
200x255x170
200x255x170
200x255x170
200x255x170

QML 1 FT 0,37
QML 1 FT 0,55
QML 1 FT 0,75
QML 1 FT 1,1
QML 1 FT 1,5

Construction

Components

Control panel for 1 pump with single-phase motor, direct starting for
pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Arranged for the capacitor internal connection (for pumps without builtin capacitor) and for the SRL 3 level control card application against dry
running.
Pump operation controlled by an electronic board type MP 1000 with
microprocessor which allows three different modes of operation of the
pump: standard, emergency and timed.

- Thermoplastic case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- Starting contactor.
- Thermal relay.
- Electronic board type MP 1000 with microprocessor.
- Terminals for pressure switch connection.
- Terminals for float switch connection against dry-running.
- Cable glands.
The panel is suitable for remote control of all the signals of the box
(excluding pump stop led and push buttons).

Technical data
- Mains single-phase 230V 10% 50 Hz

ON REQUEST:

(other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

T COMP Control panel for 1 submersible pump with three-phase motor

LVBT

Code

14013130000
14013480000
14024250000
14013560000
14013490000

Type

T COMP 8
T COMP 10
T COMP 12
T COMP 16
T COMP 20

Protector

Motor 230V - 3~

Motor 400V - 3~

Dimensions

kW

kW

HxBxP mm

18
7 10
9 12
11 16
14 20

0,37 1,5
--2,2
3
3,7 - 4

0,5 2,2
3 3,7
4
5,5
7,5

170x145x85
230x180x155
230x180x155
230x180x155
230x180x155

Construction

Components

Control panel and protection for 1 submersible pump with three-phase


motor.
Arranged for the LVBT level control internal connection against dry
running (T COMP8 model has the level control as a standard).
Control pumps with pressure switch and float-type switch.

Technical data

- Enclosure in thermoplastic material


- ON-OFF control switch
- Fuse holder - Contactor - Thermal relay
- Fuses for change of voltage: 230 V or 400 V - Transformer
- Terminals for pressure switch or float switch connection
- Terminals for LVBT board (for T COMP 10,12,16,20 models)
- Green LED indicator: voltage ON
- Red LED indicator: thermic block
- Cable glands

- Mains 230V or 400V 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

ON REQUEST:
LVBT board for level control (for T COMP 10,12,16,20 models)

638

Control panels
PFC-T Power Factor Control Control panel for 1 submersible pump with three-phase motor, PF control

Setting

Type

PFC-T 11
PFC-T 16

Dimensions

Motor
400V 50Hz - 3~

380V 60Hz - 3~

kW

kW

HxBxP mm

kg

1 - 11
1 - 16

0,37 - 4
5,5

0,37 - 4
5,5

255x200x135
255x200x135

1,7
1,7

Construction

Setting

Control panel for controlling 1 submersible pump with three-phase motor.


Electronic control of the operation and dry-running protection through the
power factor (PF) control.
The installation of level probes into the well is not required.
It stops the pump in case of lack of air cushion in the pressure vessel
(patented system)
Displayed operating data and alarms, available in four languages.

- Min Max voltage range


- Motor rated current
- Power factor (PF) value for dry-running protection
- Up to four programmable restarts in case of no water condition

Technical data

- Mains three-phase 380-400V - 3 ~ 10% 50-60 Hz


- Output current: 11 A - 16 A
- Ambient temperature from -5 C to +40 C.
- Relative humidity: from 20% to 90% without condensation
- IP 55 protection
- Control through pressure switch (pressure booster set)
- Control through float switch (for filling a tank)
- Alarm output signal
- Constructed in accordance with: IEC/EN 60439-1.

Alarms (with pump stop)


- Phase failure - Wrong phase sequence
- Undervoltage and overvoltage
- Motor overload
- No water
- No air cushion in the pressure vessel

Components
- Enclosure in thermoplastic material.
- Terminal board.
- Display : 2x16 characters. - 6 button key board.
- In/Out Cable glands.

On request: - RA 100 control panel for remote alarm.

QTL 1 FT Control panel for 1 pump with three-phase motor, direct starting

Code

---

Type

QTL 1 FT 0,55
QTL 1 FT 1,1
QTL 1 FT 1,5
QTL 1 FT 3
QTL 1 FT 4
QTL 1 FT 5,5
QTL 1 D 7,5 FT
QTL 1 D 9,2 FT
QTL 1 D 11 FT

Motor 400V - 3~

Setting

Dimensions

kW

HxBxP mm

0,37 - 0,45 - 0,55


0,75 - 1,1
1,5
2,2 - 3
4
5,5
7,5
9,2
11

1 - 1,6
1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12
13 - 18
17 - 23
20 - 25

200x255x170
200x255x170
200x255x170
200x255x170
200x255x170
200x255x170
400x300x160
400x300x160
400x300x160

Construction

Components

Control panel for 1 pump with three-phase motor, direct starting for
pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Pump operation controlled by an electronic card type MP 1000 with
microprocessor which allows three different modes of operation of the
pump: standard, emergency and timed.
Dry-running protection with float switch.
Arranged for SRL 3 level control application for probes connection against
dry-running.

- Thermoplastic case (metallic for 7,5-9,2-11kW).


- Door lock master switch.
- Fuses for power line. - Fuses for auxiliary circuit.
- Starting contactor. - Thermal relay.
- Electronic board type MP 1000 with microprocessor.
- Terminals for pressure switch connection.
- Terminals for float switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

639

53

Control panels
QTL 1 D FTE Control panel for 1 pump with three-phase motor, direct starting

Code

---

Motor 400V - 3~

Type

QTL 1 D 4 FTE
QTL 1 D 5,5 FTE
QTL 1 D 7,5 FTE
QTL 1 D 9,2 FTE
QTL 1 D 11 FTE
QTL 1 D 15 FTE
QTL 1 D 18,5 FTE
QTL 1 D 22 FTE
QTL 1 D 30 FTE

Setting

Dimensions

kW

HxBxP mm

4
5,5
7,5
9,2
11
15
18,5
22
30

6,3 - 10
9 - 12
13 - 18
17 - 23
20 - 25
24 - 32
32 - 38
35 - 50
46 - 65

400x300x160
400x300x160
400x300x160
400x300x160
400x300x160
500x350x200
500x350x200
500x350x200
500x350x200

Construction

Components

Electromechanical control panel for 1 pump with three-phase motor, direct


starting.
Operating signals by E 1000 led card.
Dry-running protection with float switch.
Construction with SRLE level control for probes connection against dryrunning on request .

- Metal case. - Door lock master switch.


- Power circuit fuses. - Fuses for auxiliary circuit.
- Starting contactor. - Thermal relay
- Transformer. - E 1000 led card.
- Terminals for connection pump operating signal.
- Terminals for float switch connection against dry-running.
- Cable glands.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- RLE level control for probes against dry running


- RLE level control for pump operating probes.
- Voltmeter. - Ammeter.

QTL 1 ST FT Control panel for 1 pump with three-phase motor, Y/ starting

Code

Type

---

QTL 1 ST 5,5 FT
QTL 1 ST 7,5 FT
QTL 1 ST 11 FT
QTL 1 ST 15 FT
QTL 1 ST 18,5 FT
QTL 1 ST 22 FT
QTL 1 ST 30B FT
QTL 1 ST 30A FT
QTL 1 ST 37 FT
QTL 1 ST 45 FT

Motor
Power
kW
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45

400V - 3~

Dimensions

Current
A

HxBxP mm

11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105

600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
700x500x200
700x500x200
700x500x200
800x600x250
800x600x250

Construction

Components

Control panel for 1 pump with three-phase motor, Y/ starting for


pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Pump operation controlled by an electronic card type MP 1000 with
microprocessor wicht 3 different pump operating modes: standard,
emergency and timed.
Dry-running protection with float switch.
Arranged for SRL 3 level control application for probes connection against
dry-running on request .

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- Starting contactors. - Thermal relay. - Transformer.
- Electronic board MP 1000 with microprocessor.
- Terminals for motor connection.
- Terminals for connection pressure switch of pump operating.
- Terminals for float switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data
- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).
- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

ON REQUEST:
- SRL 3 level control for probes against dry running
- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm .
- Voltmeter. - Ammeter.

640

Control panels
QTL 1 ST FTE Control panel for 1 pump with three-phase motor, Y/ starting

Motor
Power
kW

Code

Type

---

QTL 1 ST 5,5 FTE


QTL 1 ST 7,5 FTE
QTL 1 ST 11 FTE
QTL 1 ST 15 FTE
QTL 1 ST 18,5 FTE
QTL 1 ST 22 FTE
QTL 1 ST 30B FTE
QTL 1 ST 30A FTE
QTL 1 ST 37 FTE
QTL 1 ST 45 FTE
QTL 1 ST 55 FTE
QTL 1 ST 75 FTE
QTL 1 ST 92 FTE
QTL 1 ST 110 FTE

5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75
92
110

400V - 3~

Dimensions

Current
A

HxBxP mm

11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105
100 - 125
120 - 160
140 - 198
180 - 250

500x350x200
500x350x200
500x350x200
500x350x200
500x350x200
600x400x200
600x400x200
600x400x200
700x500x200
700x500x200
700x500x200
800x600x250
800x600x250
800x600x250

Construction

Components

Electromechanical control panel for 1 pump with three-phase motor, Y/


starting.
Operating signals by E 1000 led board.
Dry-running protection with float switch.
Construction with SRLE level control for probes connection against
dry-running on request .

- Metal case. - Door lock master switch. - Fuses for power line.
- Fuses for auxiliary circuit. - Starting contactors. - Thermal relay.
- Y/ timer. - Transformer. - E 1000 led board.
- Terminals for motor connection.
- Terminals for connection of pump operating signal.
- Terminals for float switch connection against dry-running.
- Cable glands.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- RLE level control for probes against dry running.


- RLE level control for pump operating probes.
- Voltmeter. - Ammeter.

QTL 1 SS E Control panel for 1 pump with three-phase motor, start/stop with soft starter

Motor 400V - 3~

Code

Type

---

QTL 1 SS 7,5 E
QTL 1 SS 9,2 E
QTL 1 SS 15 E
QTL 1 SS 22 E
QTL 1 SS 26 E
QTL 1 SS 30 E
QTL 1 SS 37 E
QTL 1 SS 45 E
QTL 1 SS 55 E
QTL 1 SS 63 E
QTL 1 SS 75 E
QTL 1 SS 92 E
QTL 1 SS 110 E
QTL 1 SS 132 E

Dimensions

kW

Max current
outpu
max A

7,5
9,2
11 - 15
18,5 - 22
26
30
37
45
55
63
75
92
110
132

17
22
34
48
58
68
82
92
114
126
150
196
231
245

700x500x250
700x500x250
700x500x250
700x500x250
900x600x300
900x600x300
900x600x300
900x600x300
900x600x300
1100x700x300
1100x700x300
1200x800x400
1200x800x400
1200x800x400

HxBxP mm

Construction

Components

Control panel for 1 pump with three-phase motor, start/stop with soft starter.
Operating signals on E 1000 led board.
Application: control of submersible motor with great cable length and
surface motors.
Dry-running protection with float switch.
Construction with SRLE level control for probes connection against dryrunning on request .

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- Soft starter - Transformer.
- By pass contactors (built into the soft starter) - E 1000 led board.
- Terminals for float switch or level probes connection for pump operating.
- Terminals for float switch or level probes connection against dry-running.
- Cable glands.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- RLE level control for connection level probes of pump operating.


- RLE level control for probes against dry running.
- Voltmeter. - Ammeter.

641

53

Control panels
QTL 1 IS FTE Control panel for 1 pump with three-phase motor, with Stator Impedence starter

Code

Type

---

QTL 1 IS 5,5 FTE-2RL


QTL 1 IS 7,5 FTE-2RL
QTL 1 IS 11 FTE-2RL
QTL 1 IS 15 FTE-2RL
QTL 1 IS 18,5 FTE-2RL
QTL 1 IS 22 FTE-2RL
QTL 1 IS 30 FTE-2RL
QTL 1 IS 37 FTE-2RL
QTL 1 IS 45 FTE-2RL
QTL 1 IS 55 FTE-2RL
QTL 1 IS 75 FTE-2RL
QTL 1 IS 92 FTE-2RL
QTL 1 IS 110 FTE-2RL

Motor
Power
kW
5,5
7,5
9,2 - 11
15
18,5
22
30
37
45
55
75
92
110

400V - 3~

Current
A

Dimensions
HxBxP mm

11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42- 65
61 - 84
80 - 105
100 - 125
120 - 160
140 - 198
180 - 250

Construction

Components

Electromechanical control panel for 1 submersible pump with three-phase


motor, with Stator Impedence starter.
Operating signals on led board type E 1000.
Application : submersible motors control with great cable length.
Construction with SRLE level control for probes connection against dryrunning .

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- Stator Impedence - By pass contactors
- Transformer. - E 1000 led board.
- RLE level control for connection level probes of pump control.
- RLE level control for probes against dry running.
- Terminals for connection level probes or float switch for operating pump.
- Terminals for level probes or float switch connection against dry-running.
- Cable glands.

Technical data
- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).
- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

ON REQUEST:
- Voltmeter. - Ammeter.

642

Control panels
QML 2 D Control panel for 2 pumps with single-phase motor, direct starting

Code

Type

---

QML 2 D 0,45
QML 2 D 0,55
QML 2 D 0,75
QML 2 D 1,1
QML 2 D 1,5

Motor 230V - 1~

Protector

Dimensions

kW

max A

HxBxP mm

0,37 - 0,45
0,55
0,75
1,1
1,5

4
6
7
9
12

200x255x110
200x255x110
200x255x110
200x255x110
200x255x110

Construction

Components

Control panel for 2 pumps with single-phase motor, direct starting for
pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation cascade mode controlled by an electronic board type MP
2000 with microprocessor which allows three different operation modes:
standard, emergency and timed.

- Thermoplastic case.- Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- Starting relay. - Circuit breaker.
- Two capacitor (on request)
- Electronic board type MP 2000 with microprocessor.
- Terminals for pressure switch connection.
- Terminals for float switch or float switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data

ON REQUEST:

- Mains single-phase 230V 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

QTL 2 FT Control panel for 2 pumps with three-phase motor, direct starting

Motor 400V - 3~

Code

Type

---

QTL 2 FT 0,45
QTL 2 FT 0,55
QTL 2 FT 1,1
QTL 2 FT 1,5
QTL 2 FT 3
QTL 2 FT 4
QTL 2 FT 5,5

Setting

Dimensions

kW

max A

HxBxP mm

0,37 - 0,45
0,55
0,75 - 1,1
1,5
2,2 - 3
4
5,5

0,9 - 1,5
1,4 - 2,3
2 - 3,3
3-5
4,5 - 7,5
6,3 - 10
9 - 12

230x310x130
230x310x130
230x310x130
230x310x130
230x310x130
230x310x130
230x310x130

Construction

Components

Control panel for 2 pumps with three-phase motor, direct starting for
pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation cascade mode controlled by an electronic board type MP
2000 with microprocessor which allows three different operation modes:
standard, emergency and timed.

- Thermoplastic case.
- Door lock master switch.
- Fuses for power line. - Fuses for auxiliary circuit.
- Starting contactors. - Thermal relay.
- Electronic board type MP 2000 with microprocessor.
- Terminals for pressure switch connection.
- Terminals for float switch or flow switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

643

53

Control panels
QTL 2 ST FT Control panel for 2 pumps with three-phase motor, Y/ starting

Code

---

Motor
Power
kW

Type

QTL 2 ST 5,5 FT
QTL 2 ST 7,5 FT
QTL 2 ST 11 FT
QTL 2 ST 15 FT
QTL 2 ST 18,5 FT
QTL 2 ST 22 FT
QTL 2 ST 30B FT
QTL 2 ST 30A FT
QTL 2 ST 37 FT
QTL 2 ST 45 FT

400V - 3~

5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45

Current
A
11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105

Dimensions
HxBxP mm
700x500x200
700x500x200
700x500x200
700x500x200
700x500x200
900x600x250
900x600x250
900x600x250
1100x700x250
1100x700x250

Construction

Components

Control panel for 2 pumps with three-phase motor, Y/ starting, for


pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Pump operation cascade mode controlled by an electronic board type MP
2000 with microprocessor which allows three different operation modes:
standard, emergency and timed.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- Starting contactors. - Thermal relay. - Y/ timers. - Transformer.
- Electronic board type MP 2000 with microprocessor.
- Terminals for pressure switch connection.
- Terminals for float switch or float switch connection against dry-running.
- Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Voltmeter. - Ammeter. - Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

QML 3 FT Control panel for 3 pumps with single-phase motor, direct starting

Code

Type

---

QML 3 FT 0,37
QML 3 FT 0,55
QML 3 FT 0,75
QML 3 FT 1,1
QML 3 FT 1,5
QML 3 FT 2,2

Motor 230V - 1~

Setting

Dimensions

kW

max A

HxBxP mm

0,37
0,45 - 0,55
0,75
1,1
1,5
2,2

1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12
13 - 18

390x470x130
390x470x130
390x470x130
390x470x130
390x470x130
390x470x130

Construction

Components

Control panel for 2 pumps with single-phase motor, direct starting for
pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel .
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation cascade mode controlled by an electronic board type MP
2000 with microprocessor which allows three different operation modes:
standard, emergency and timed.

- Thermoplastic case.
- Door lock master switch.
- Fuses for power line. - Fuses for auxiliary circuit.
- Starting relay. - Circuit breaker.
- Electronic board type MP 3000 with microprocessor.
- Terminals for pressure switch connection.
- Terminals for float switch or float switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data

ON REQUEST:

- Mains single-phase 230V 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

644

Control panels
QTL 3 FT Control panel for 3 pumps with three-phase motor, direct starting

Code

Type

Motor 400V - 3~

Setting

kW

max A

HxBxP mm

---

QTL 3 FT 0,55
QTL 3 FT 1,1
QTL 3 FT 1,5
QTL 3 FT 3
QTL 3 FT 4
QTL 3 FT 5,5

0,37 - 0,45 - 0,55


0,75 - 1,1
1,5
2,2 - 3
4
5,5

1 - 1,6
1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12

470x390x170
470x390x170
470x390x170
470x390x170
470x390x170
470x390x170

Dimensions

Construction

Components

Control panel for 3 pumps with three-phase motor, direct starting, for
pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel .
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation cascade mode controlled by an electronic board type MP
3000 with microprocessor which allows three different operation modes:
standard, emergency and timed.

- Thermoplastic case.
- Door lock master switch.
- Fuses for power line. - Fuses for auxiliary circuit.
- Starting contactors. - Thermal relay.
- Electronic board type MP 3000 with microprocessor.
- Terminals for pressure switch connection.
- Terminals for float switch or flow switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

QTL 3 ST FT Control panel for 3 pumps with three-phase motor, Y/ starting

Code

---

Type

QTL 3 ST 5,5 FT
QTL 3 ST 7,5 FT
QTL 3 ST 11 FT
QTL 3 ST 15 FT
QTL 3 ST 18,5 FT
QTL 3 ST 22 FT
QTL 3 ST 30B FT
QTL 3 ST 30A FT
QTL 3 ST 37 FT
QTL 3 ST 45 FT

Motor
Power
kW
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45

400V - 3~

Current
A
11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105

Dimensions
HxBxP mm
800x600x250
800x600x250
800x600x250
800x600x250
1000x600x250
1100x700x250
1200x800x300
1200x800x300
1400x800x400
1400x800x400

Construction

Components

Control panel for 3 pumps with three-phase motor, Y/ starting, for


pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation cascade mode controlled by an electronic board type MP
3000 with microprocessor which allows three different operation modes:
standard, emergency and timed.

- Metal case. - Door lock master switch. - Fuses for power line.
- Fuses for auxiliary circuit. - Starting contactors.
- Thermal relay. - Y/ timers. - Transformer.
- Electronic board type MP 3000 with microprocessor.
- Terminals for pumps connection.
- Terminals for pressure switch connection.
- Terminals for float switch or flow switch connection against dry-running.
- Terminals for remote signals - Cable glands.

Technical data
- Mains 400V 10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

ON REQUEST:
- SRL 3 level control for probes against dry running
- Voltmeter. - Ammeter.
- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

645

53

Control panels
QTL 4 D FT Control panel for 4 pumps with three-phase motor, direct starting

Code

---

Type

QTL 4 D 0,55 FT
QTL 4 D 1,1 FT
QTL 4 D 1,5 FT
QTL 4 D 3 FT
QTL 4 D 4 FT
QTL 4 D 5,5 FT

Motor 400V - 3~

Setting

kW

max A

HxBxP mm

0,37- 0,45 - 0,55


0,75 - 1,1
1,5
2,2 - 3
4
5,5

1 - 1,6
1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12

600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
600x400x200

Construction

Components

Control panel for 4 pumps with three-phase motor, direct starting, for
pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation cascade mode controlled by an electronic board type MP
6000 with microprocessor alternating the starting order and allows three
different operation modes: standard, emergency and timed.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- Starting contactors.
- Thermal relay. - Transformer.
- Electronic board type MPS 6000 with microprocessor.
- Terminals for pressure transducer connection.
- Terminals for float switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M.
- RA 100 control panel for remote alarm.

Dimensions

QTL 4 ST FT Control panel for 4 pumps with three-phase motor, Y/ starting

5,5 45 kW
Code

---

Type

QTL 4 ST 5,5 FT
QTL 4 ST 7,5 FT
QTL 4 ST 11 FT
QTL 4 ST 15 FT
QTL 4 ST 18,5 FT
QTL 4 ST 22 FT
QTL 4 ST 30B FT
QTL 4 ST 30A FT
QTL 4 ST 37 FT
QTL 4 ST 45 FT

Motor
Power
kW
5,5
7,5
11
15
18,5
22
30
30
37
45

400V - 3~

Current
A

Dimensions
HxBxP mm

11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105

900x600x250
900x600x250
1000x800x250
1000x800x250
1200x800x250
1200x800x250
1200x800x250
1400x800x400
1400x800x400

Construction

Components

Control panel for 3 pumps with three-phase motor, Y/ starting, for


pressure booster sets, with a patented working time-measuring system
that stops the pump in case of lack of air cushion in the pressure vessel.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation cascade mode controlled by an electronic board type MP
6000 with microprocessor alternating the starting order and allows three
different operation modes: standard, emergency and timed.

- Metal case. - Door lock master switch. - Fuses for power line.
- Fuses for auxiliary circuit. - Starting contactors.
- Thermal relay. - Y/ timers. - Transformer.
- Electronic board type MPS 6000 with microprocessor.
- Terminals for pumps connection.
- Terminals for pressure transducer connection.
- Terminals for float switch connection against dry-running.
- Terminals for remote signals
- Cable glands.

Technical data
- Mains 400V 10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

ON REQUEST:
- SRL 3 level control for probes against dry running
- Voltmeter. - Ammeter.

646

Control panels
QML 1 VFT Control panel for 1 pump with variable speed three-phase motor.

Code

Motor 230V - 3~

Type

kW
---

QML 1 VFT 0,4


QML 1 VFT 0,75
QML 1 VFT 1,5
QML 1 VFT 2,2

0,37 - 0,45
0,55 - 0,75
1,1 - 1,5
2,2

Max current
outpu
max A
2,4
4,2
7,5
10

Dimensions
HxBxP mm
500x350x200
500x350x200
500x350x200
500x350x200

Construction

Components

Single-phase mains supply control panel with frequency converter for 1


pump with three-phase 230V variable speed motor, for constant pressure
booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- EMC filter. - Frequency converter. - MPS 4000 electronic card.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling.
- Terminals board. - Terminals for remote signals
- Pressure transducer - Cable glands.

Technical data

ON REQUEST:

- Mains single-phase 230V 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 9M.
- RA 100 control panel for remote alarm.

QTL 1 VFT Control panel for 1 pump with variable speed three-phase motor

Motor 400V - 3~

Code

Type

14046510000
14046520000
14046530000
14046540000
14046550000
14046560000
14046570000
14046580000
14046590000
14046600000
14046610000
14046620000
14046630000
14046640000
14046650000
14046660000

QTL 1 VFT 0,4


QTL 1 VFT 0,75
QTL 1 VFT 1,5
QTL 1 VFT 2,2
QTL 1 VFT 4
QTL 1 VFT 5,5
QTL 1 VFT 7,5
QTL 1 VFT 11
QTL 1 VFT 15
QTL 1 VFT 18,5
QTL 1 VFT 22
QTL 1 VFT 30
QTL 1 VFT 37
QTL 1 VFT 45
QTL 1 VFT 55
QTL 1 VFT 75

kW
0,4
0,55 - 0,75
1,1 - 1,5
2,2
3-4
5,5
7,5
9,2 - 11
15
18,5
22
30
37
45
55
75

Max current
outpu
max A
1,5
2,3
4,1
5,5
9,5
14,3
17
27,7
33
41
48
66
79
94
116
160

Dimensions
HxBxP mm
500x350x200
500x350x200
500x350x200
500x350x200
500x350x200
600x400x200
600x400x200
700x500x200
700x500x200
800x600x250
800x600x250
800x600x250
1100x700x300
1200x800x300
1200x800x300
1200x800x300

Construction

Components

Control panel with frequency converter for 1 pump with three-phase


variable speed motor, for constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- EMC filter. - Frequency converter. - MPS 4000 electronic board.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling.
- Terminals board. - Terminals for remote signals
- Pressure transducer - Cable glands.

Technical data

ON REQUEST:

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 9M.
- RA 100 control panel for remote alarm.

647

53

Control panels
QML 2 VFT Control panel for 2 pumps with variable speed three-phase motor

Code

Motor 230V - 3~

Type

Max current
outpu
max A

kW
---

0,37 - 0,45
0,55 - 0,75
1,1 - 1,5
2,2

QML 2 VFT 0,4


QML 2 VFT 0,75
QML 2 VFT 1,5
QML 2 VFT 2,2

2,4x2
4,2x2
7,5x2
10x2

Dimensions
HxBxP mm
600x400x200
600x400x200
600x400x200
600x400x200

Construction

Components

Single-phase mains supply control panel with frequency converter for 2


pumps with three-phase 230V variable speed motor, for constant
pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit. - EMC filter.
- Frequency converter (1 for each pump).
- MPS 4000 electronic board.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling.
- Terminals board. - Terminals for remote signals
- Pressure transducer - Cable glands.

Technical data

ON REQUEST:

- Mains single-phase 230V 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 9M.
- RA 100 control panel for remote alarm.

QTL 2 VFT Control panel for 2 pumps with variable speed three-phase motor

Code

Type

Motor 400V - 3~
kW

14046670000
14046680000
14046690000
14046700000
14046710000
14046720000
14046730000
14046740000
14046750000
14046760000
14046770000
14046780000
14046790000
14046800000
14046810000
14046820000

QTL 2 VFT 0,4


QTL 2 VFT 0,75
QTL 2 VFT 1,5
QTL 2 VFT 2,2
QTL 2 VFT 4
QTL 2 VFT 5,5
QTL 2 VFT 7,5
QTL 2 VFT 11
QTL 2 VFT 15
QTL 2 VFT 18,5
QTL 2 VFT 22
QTL 2 VFT 30
QTL 2 VFT 37
QTL 2 VFT 45
QTL 2 VFT 55
QTL 2 VFT 75

0,4
0,55 - 0,75
1,1 - 1,5
2,2
3-4
5,5
7,5
9,2 - 11
15
18,5
22
30
37
45
55
75

Max current
outpu
max A

Dimensions

1,5x2
2,3x2
4,1x2
5,5x2
9,5x2
14,3x2
17x2
27,7x2
33x2
41x2
48x2
66x2
79x2
94x2
116x2
160x2

600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
700x500x200
700x500x200
1000x800x250
1000x800x250
1200x800x300
1200x800x300
1200x800x300
1600x1000x400
2100x1400x500
2100x1400x500
2100x1400x500

HxBxP mm

Construction

Components

Control panel with frequency converter for 2 pump with three-phase


variable speed motor, for constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- EMC filter. - Frequency converter.
- MPS 4000 electronic board.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 9M.
- RA 100 control panel for remote alarm.

648

Control panels
QML 1.1 VFT Control panel for 1 variable speed pump and 1 fixed speed pump

Code

Motor 230V - 3~

Type

kW
---

QML 1.1 VFT 0,4 - D 0,4


QML 1.1 VFT 0,75 - D 0,75
QML 1.1 VFT 1,5 - D 1,5
QML 1.1 VFT 2,2 - D 2,2

Max current
outpu
max A
2,4
4,2
7,5
10

0,37 - 0,45
0,55 - 0,75
1,1 - 1,5
2,2

Dimensions
HxBxP mm
600x400x200
600x400x200
600x400x200
600x400x200

Construction

Components

Single-phase mains supply control panel with frequency converter for 2


pumps, one with three-phase 230V variable speed motor and one with
fixed speed single-phase motor, for constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- EMC filter. - Frequency converter.
- Starting contactors of the second pump. - Transformer.
- MPS 4000 electronic board.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:

- Mains single-phase 230V 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 9M.
- RA 100 control panel for remote alarm.

QTL 1.1 VFT Control panel for 1 variable speed pump and 1 fixed speed pump
Code
--14047460000
14047230000
14047130000
14047160000
14047120000
14047030000
14048390000
14048210000

Type
QTL 1.1 VFT 0,4 - D 0,4
QTL 1.1 VFT 0,75 - D 0,75
QTL 1.1 VFT 1,5 - D 1,5
QTL 1.1 VFT 2,2 - D 2,2
QTL 1.1 VFT 4 - D 3
QTL 1.1 VFT 4 - D 4
QTL 1.1 VFT 5,5 - D 5,5
QTL 1.1 VFT 7,5 - ST 7,5
QTL 1.1 VFT 11 - ST 11
QTL 1.1 VFT 15 - ST 15
QTL 1.1 VFT 18,5 - ST 18,5
QTL 1.1 VFT 22 - ST 22
QTL 1.1 VFT 30 - ST 30B
QTL 1.1 VFT 30 - ST 30A
QTL 1.1 VFT 37 - ST 37
QTL 1.1 VFT 45 - ST 45
QTL 1.1 VFT 55 - ST 55
QTL 1.1 VFT 75 - ST 75

Motor 400V - 3~
kW

Max current
outpu
max A

0,4
0,55 - 0,75
1,1 - 1,5
2,2
3
4
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75

1,5
2,3
4,1
5,5
9,5
9,5
14,3
17
27,7
33
41
48
66
66
79
94
116
160

Dimensions
HxBxP mm
600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
700x500x200
700x500x200
800x600x250
800x600x250
1000x800x250
1000x800x250
1000x800x250
1000x800x250
1200x800x300
1200x800x300
1200x800x300
1200x800x300

Construction

Components

Control panel with frequency converter for 2 pumps with three-phase


motor, one with variable speed and one with fixed speed motor, for
constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch. - Fuses for power line.
- Fuses for auxiliary circuit. - EMC filter. - Frequency converter.
- Starting contactors of the second pump. - Timer (Y/) from 7,5 kW.
- Transformer. - MPS 4000 electronic card.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 9M.
- RA 100 control panel for remote alarm.

649

53

Control panels
QML 3 VFT Control panel for 3 variable speeds pump with three-phase motor

Code

Motor 230V - 3~

Type

kW
---

QML 3 VFT 0,4


QML 3 VFT 0,75
QML 3 VFT 1,5
QML 3 VFT 2,2

Max current
outpu
max A

Dimensions

2,4x3
4,2x3
7,5x3
10x3

700x500x200
700x500x200
700x500x200
700x500x200

0,37 - 0,45
0,55 - 0,75
1,1 - 1,5
2,2

Construction

Components

Single-phase mains supply control panel with frequency converter for 3


pumps with three-phase 230V variable speed motor, for constant
pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- EMC filter. - Frequency converter (1 for each pump).
- MPS 4000 electronic card.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling.
- Terminals board. - Terminals for remote signals
- Pressure transducer - Cable glands.

Technical data

ON REQUEST:

- Mains single-phase 230V 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 13M.
- RA 100 control panel for remote alarm.

HxBxP mm

QTL 3 VFT Control panel for 3 pumps with variable speed three-phase motor

Code

Type

Motor 400V - 3~
kW

--14046930000
14047140000
14047040000
14048250000

14047150000
14047270000

QTL 3 VFT 0,4


QTL 3 VFT 0,75
QTL 3 VFT 1,5
QTL 3 VFT 2,2
QTL 3 VFT 4
QTL 3 VFT 5,5
QTL 3 VFT 7,5
QTL 3 VFT 11
QTL 3 VFT 15
QTL 3 VFT 22
QTL 3 VFT 30
QTL 3 VFT 37
QTL 3 VFT 45
QTL 3 VFT 55
QTL 3 VFT 75

0,4
0,55 - 0,75
1,1 - 1,5
2,2
3-4
5,5
7,5
9,2 - 11
15
18,5 - 22
30
37
45
55
75

Max current
outpu
max A
1,5x3
2,3x3
4,1x3
5,5x3
9,5x3
14,3x3
17x3
27,7x3
33x3
48x3
66x3
79x3
94x3
116x3
160x3

Dimensions
HxBxP mm
700x500x200
700x500x200
700x500x200
700x500x200
700x500x200
1000x800x250
1000x800x250
1700x1000x400
1700x1000x400
1700x1000x400
1700x1000x400
A richiesta
A richiesta
A richiesta
A richiesta

Construction

Components

Control panel with frequency converter for 3 pumps with variable speed
three-phase motor, for constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- EMC filter. - Frequency converter (1 for each pump).
- MPS 4000 electronic card.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 13M.
- RA 100 control panel for remote alarm.

650

Control panels
QTL 1.2 VFT Control panel for 1 variable speed pump and 2 fixed speed pumps
Code

Motor 400V - 3~

Type

kW

14047640000
14048510000
14048260000
14047200000
14047300000

14048660000

Max current
outpu
max A

0,4
0,55 - 0,75
1,1 - 1,5
2,2
3
4
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75

QTL 1.2 VFT 0,4 - D 0,4


QTL 1.2 VFT 0,75 - D 0,75
QTL 1.2 VFT 1,5 - D 1,5
QTL 1.2 VFT 2,2 - D 2,2
QTL 1.2 VFT 4 - D 3
QTL 1.2 VFT 4 - D 4
QTL 1.2 VFT 5,5 - D 5,5
QTL 1.2 VFT 7,5 - ST 7,5
QTL 1.2 VFT 11 - ST 11
QTL 1.2 VFT 15 - ST 15
QTL 1.2 VFT 18,5 - ST18,5
QTL 1.2 VFT 22 - ST 22
QTL 1.2 VFT 30 - ST 30B
QTL 1.2 VFT 30 - ST 30A
QTL 1.2 VFT 37 - ST 37
QTL 1.2 VFT 45 - ST 45
QTL 1.2 VFT 55 - ST 55
QTL 1.2 VFT 75 - ST 75

1,5
2,3
4,1
5,5
9,5
9,5
14,3
17
27,7
33
41
48
66
66
79
94
116
160

Dimensions
HxBxP mm
600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
700x500x200
800x600x250
900x600x250
900x600x250
900x600x250
1000x800x250
1000x800x250
1000x800x250
1200x800x300

Construction

Components

Control panel with frequency converter for 3 pumps with three-phase


motor: one with variable speed motor (with frequency converter) and 2
with fixed speed motor, for constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch. - Fuses for power line.
- Fuses for auxiliary circuit. - EMC filter. - Frequency converter.
- Starting contactors of the second and third pump.
- Timer (Y/) from 7,5 kW. - Transformer.
- MPS 4000 electronic board.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:
- SRL 3 level control for probes against dry running
- Volt free contact module MSP 1M, MPS 13M.
- RA 100 control panel for remote alarm.

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

QTL 4 VFT Control panel for 4 pumps with variable speed three-phase motor
Code

Type

Motor 400V - 3~
kW

14047840000

QTL 4 VFT 0,4


QTL 4 VFT 0,75
QTL 4 VFT 1,5
QTL 4 VFT 2,2
QTL 4 VFT 4
QTL 4 VFT 5,5
QTL 4 VFT 7,5
QTL 4 VFT 11
QTL 4 VFT 15
QTL 4 VFT 22
QTL 4 VFT 30
QTL 4 VFT 37
QTL 4 VFT 45
QTL 4 VFT 55
QTL 4 VFT 75

0,4
0,55 - 0,75
1,1 - 1,5
2,2
3-4
5,5
7,5
9,2 - 11
15
18,5 - 22
30
37
45
55
75

Max current
outpu
max A
1,5x4
2,3x4
4,1x4
5,5x4
9,5x4
14,3x4
17x4
27,7x4
33x4
48x4
66x4
79x4
94x4
116x4
160x4

Dimensions
HxBxP mm
900x600x250
900x600x250
900x600x250
900x600x250
900x600x250
1200x800x300
1200x800x300
1700x1000x400
1700x1000x400
2000x1800x400
2000x1800x400
2000x1800x400
2000x1800x400
2000x1800x400
2000x1800x400

Construction

Components

Control panel with frequency converter for 4 pumps with variable speed
three-phase motor, for constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch.


- Fuses for power line. - Fuses for auxiliary circuit.
- EMC filter. - Frequency converter (1 for each pump).
- MPS 4000 electronic board.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 13M.
- RA 100 control panel for remote alarm.

651

53

Control panels
QTL 1.3 VFT Control panel for 1 variable speed pump and 3 fixed speed pumps
Code

Type

---

QTL 1.3 VFT 0,4 - D 0,4


QTL 1.3 VFT 0,75 - D 0,75
QTL 1.3 VFT 1,5 - D 1,5
QTL 1.3 VFT 2,2 - D 2,2
QTL 1.3 VFT 4 - D 3
QTL 1.3 VFT 4 - D 4
QTL 1.3 VFT 5,5 - D 5,5
QTL 1.3 VFT 7,5 - ST 7,5
QTL 1.3 VFT 11 - ST 11
QTL 1.3 VFT 15 - ST 15
QTL 1.3 VFT 18,5 - ST 18,5
QTL 1.3 VFT 22 - ST 22
QTL 1.3 VFT 30 - ST 30B
QTL 1.3 VFT 30 - ST 30A
QTL 1.3 VFT 37 - ST 37
QTL 1.3 VFT 45 - ST 45
QTL 1.3 VFT 55 - ST 55
QTL 1.3 VFT 75 - ST 75

14046890000

Motor 400V - 3~
kW
0,4
0,55 - 0,75
1,1 - 1,5
2,2
3
4
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75

Max current
outpu
max A
1,5
2,3
4,1
5,5
9,5
9,5
14,3
17
27,7
33
41
48
66
66
79
94
116
160

Dimensions
HxBxP mm
800x600x250
800x600x250
800x600x250
800x600x250
800x600x250
800x600x250
1100x700x250
1100x700x250
1200x800x300
1200x800x300
1200x800x300
1200x800x300
1200x800x300
1200x800x300
1700x800x400
1700x800x400

Construction

Components

Control panel with frequency converter for 4 pumps with three-phase


motor: one with variable speed motor (with frequency converter) and 3
with fixed speed motor, for constant pressure booster sets.
Arranged for SRL 3 level control application for probes connection against
dry-running.
Pump operation controlled by an electronic board type MPS 4000 with
microprocessor alternating the starting order at each start.

- Metal case. - Door lock master switch. - Fuses for power line.
- Fuses for auxiliary circuit. - EMC filter. - Frequency converter.
- Starting contactors of the second, third and fourth pump.
- Timer (Y/) from 7,5 kW. - Transformer. - MPS 4000 electronic board.
- Interface for MPS 4000 electronic board.
- Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.

Technical data

ON REQUEST:

- Mains 400V 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 44.

- SRL 3 level control for probes against dry running


- Volt free contact module MSP 1M, MPS 13M.
- RA 100 control panel for remote alarm.

652

Control panels
QMLD 1 D Control panel for 1 submersible drainage pump with single-phase motor, direct starting

Code

---

Type

Setting

Capacitor

kW

450Vc

HxBxP mm

0,25 1,1
0,25 1,1
0,25 1,1

1 12 A
1 12 A
1 12 A

20 F
25 F

200x255x135
200x255x135
200x255x135

Motor 230V - 1~

QMLD 1D 12A-FA
QMLD 1D 12A-FA-20
QMLD 1D 12A-FA-25

Dimensions

Construction

Components

Control panel with protection for 1 submersible drainage pump with


single-phase motor, with a 12A max. nominal current.
Possibility to install one capacitor inside the control panel, for pumps
without capacitor inside the motor.
Operation managed by a DR 1000 type electronic board with
microprocessor that has the following functions:
- automatic operating test of the pump every 48 hours of inactivity (with
pump in the automatic operating mode).
- Pump control with signals coming from:
- 2 float switches: one for starting-up and stopping pump, one for the
alarm maximum level (optional).
- 3 float switches: one for starting-up pump, one for stopping the pump
and one for the alarm maximum level (optional).

- Thermoplastic case.
- Line selector switch with door-locking device.
- Power line fuses.
- Auxiliary circuit fuses.
- Starting-up relay.
- Amperometric transformer.
- Capacitor (on request).
- DR 1000 type electronic board with microprocessor.
- Terminals for capacitor connection.
- Terminals for float switches connection.
- Terminals for connection of remote alarm control panel RA 100E, RA
100A type.
- Cable glands.
The panel is suitable for remote control of all the signals of the box.

Technical data

ON REQUEST:

- Mains: 230V 1~ 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- Volt free contact module MSP 1M - MSP 9M.


- RA 100 - RA 100A control panel for remote alarm.

QTLD 1 D Control panel for 1 submersible drainage pump with three-phase motor, direct starting

Code

14039020000

Type

Motor 400V - 3~

Setting

kW

HxBxP mm

0,25 5

1 12 A

200x255x135

QTLD 1D 12A-FA

Dimensions

Construction

Components

Control panel with protection for 1 submersible drainage pump with threephase motor, with a 12A max. nominal current.
Operation managed by a DR 1000 type electronic board with
microprocessor that has the following functions:
- automatic operating test of the pump every 48 hours of inactivity (with
pump in the automatic operating mode).
- Pump control with signals coming from:
- 2 float switches: one for starting-up and stopping pump, one for the
alarm maximum level (optional).
- 3 float switches: one for starting-up pump, one for stopping the pump
and one for the alarm maximum level (optional).

- Thermoplastic case.
- Line selector switch with door-locking device.
- Power line fuses.
- Auxiliary circuit fuses.
- Contactor.
- Amperometric transformer.
- DR 1000 electronic board with microprocessor.
- Terminals for float switches connection.
- Connection terminals for the RA 100 RA 100A type remote alarm control
panel or volt free contact module.
- Cable glands.

Technical data

ON REQUEST:

- Mains: 400V 3~ 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- Volt free contact module MSP 1M - MSP 9M.


- RA 100 - RA 100A control panel for remote alarm.

653

53

Control panels
QTLD 1 ST FT Control panel for 1 submersible drainage pump with three-phase motor, Y/ starting
Code
---

QTLD 1ST 4
QTLD 1ST 5,5
QTLD 1ST 7,5
QTLD 1ST 11
QTLD 1ST 15
QTLD 1ST 18,5
QTLD 1ST 22
QTLD 1ST 30B
QTLD 1ST 30A
QTLD 1ST 37
QTLD 1ST 45
QTLD 1ST 55
QTLD 1ST 75
QTLD 1ST 92

Construction
Control panel with protection for 1 submersible drainage pump with three-phase
motor, Y/ starting.
Operation managed by the DR1000 electronic circuit board that has the
following functions:
- automatic operating test of the pump every 24 hours of inactivity (with
pump in the automatic operating mode).
- Pump control with signals coming from:
- 2 float switches: for starting-up and stopping pump, for the alarm
(maximum level is optional).
- 3 float switches: for starting-up pump, for stopping the pump and for
the alarm (maximum level is optional).

Technical data
- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).
- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

Motor
Power
kW

Type
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL

4
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75
92

400V - 3~

Current
A
7 - 11
11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105
100 - 125
120 - 150
155 - 255

Dimensions
HxBxP mm
600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
600x400x200
700x500x250
700x500x250
700x500x250
800x600x250
800x600x250
1100x700x250
1100x700x250
1100x700x250

Components
- Metal case. - Line selector switch with door-locking device.
- Power line fuses. - Auxiliary circuit fuses. - Contactors.
- Y/ timer. - Thermal relay. - Level regulator.
- DR 1000 type circuit board with microprocessor.
- Connection terminals for float switches or level probes.
- Connection terminals for thermal protectors.
- Connection terminals for water seepages probe.
- Connection terminals for the RA 100 RA 100A type remote alarm control
panel or volt free contact module.
- Cable glands.

ON REQUEST:
- Volt free contact module MSP 1M - MSP 9M.
- RA 100 - RA 100A control panel for remote alarm.
- Voltmeter. - Ammeter.

654

Control panels
QMLD 2 D Control panel for 2 submersible drainage pumps with single-phase motor, direct starting

Code

---

Type

Motor 230V - 1~

Setting

Capacitor

kW

450Vc

HxBxP mm

0,25 1,1
0,25 1,1
0,25 1,1
0,25 1,1

1 12 A
1 12 A
1 12 A
1 12 A

2x20 F
2x25 F
2x35 F

230x310x130

QMLD 2D 12A-FA ....


QMLD 2D 12A-FA 20
QMLD 2D 12A-FA 25
QMLD 2D 12A-FA 35-85

Construction
Control panel with protection for 2 submersible drainage pumps with
single-phase motor, with a 12A max. nominal current.
Possibility to install two capacitors inside the control panel, for pump
without capacitor inside the motor.
Operation managed by the DR 2000 electronic board that has the following
functions:
- pump changing at every pump start.
- working pumps changing after 30 minutes of uninterrupted operation.
- automatic operating test of each individual pump every 48 hours of
inactivity (with pumps in the automatic functioning mode).
- Pump control with signals coming from:
- 3 float switches: for starting-up and stopping pump 1, for starting-up
and stopping pump 2, for the alarms (maximum level is optional).
- 4 float switches: for starting-up pump 1, for starting up pump 2, for
stopping the pumps and for the alarms (maximum level is optional).

Technical data

Dimensions

230x310x130
230x310x130
470x390x170

Components
- Box in thermoplastic material.
- Line selector switch with door-locking device.
- Power line fuses.
- Auxiliary circuit fuses.
- Starting-up relays.
- Amperometric transformers.
- Capacitors (on request).
- DR 2000 electronic board with microprocessor.
- Terminals for capacitors connection.
- Terminals for float switches connection.
- Terminals for connection the RA 100E, RA 100A type remote alarm
control panel or volt free contact module.
- Cable glands.
The panel is suitable for remote control of all the signals of the box.

ON REQUEST:

- Mains: 230V 1~ 10% 50/60 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

- Volt free contact module MSP 1M - MSP 9M.


- RA 100 - RA 100A control panel for remote alarm.

QTLD 2 D Control panel for 2 submersible drainage pumps with three-phase motor, direct starting

Code

---

Type

Motor 400V - 3~

QTLD 2D 12A-FA

Setting

Dimensions

kW

HxBxP mm

0,25 5

1 12 A

230x310x130

Construction

Components

Control panel with protection for 2 submersible drainage pumps with


three-phase motors, with a 12A max. nominal current.
Operation managed by the DR 2000 electronic card that incorporates the
following functions:
- changes pumps at every pump start.
- changes working pumps after 30 minutes of uninterrupted operation.
- automatic functioning test of each individual pump every 48 hours of
inactivity (with pumps in the automatic functioning mode).
- Pump control with signals coming from:
- 3 float switches: for starting-up and stopping pump 1, for starting-up
and stopping pump 2, for the alarms (maximum level is optional).
- 4 float switches: for starting-up pump 1, for starting up pump 2, for
stopping the pumps and for the alarms (maximum level is optional).

- Box in thermoplastic material.


- Line selector switch with door-locking device.
- Power line fuses.
- Auxiliary circuit fuses.
- Contactors.
- Amperometric transformers.
- DR 2000 type electronic board with microprocessor.
- Connection terminals for float switches.
- Terminals for connection the RA 100A type remote alarm control panel
or volt free contact module.
- Cable glands.
The panel is suitable for remote control of all the signals of the box.

Technical data

ON REQUEST:

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C. - Protection IP 55.

- Volt free contact module MSP 1M - MSP 9M.


- RA 100A control panel for remote alarm.

655

53

Control panels
QTLD 2 ST FT Electric control panel for 2 drainage pumps with three-phase motor, Y/ starting
Code
---

Motor
Power
kW

Type
QTLD 2ST 4
QTLD 2ST 5,5
QTLD 2ST 7,5
QTLD 2ST 11
QTLD 2ST 15
QTLD 2ST 18,5
QTLD 2ST 22
QTLD 2ST 30B
QTLD 2ST 30A
QTLD 2ST 37
QTLD 2ST 45
QTLD 2ST 55
QTLD 2ST 75
QTLD 2ST 92

FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL

4
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75
92

400V - 3~

Current
A
7 - 11
11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105
100 - 125
120 - 150
155 - 255

Dimensions
HxBxP mm
700x500x200
700x500x200
700x500x200
700x500x200
700x500x200
700x500x200
900x600x250
900x600x250
900x600x250
1100x700x250
1100x700x250
1200x800x300
1200x800x300
1400x800x400

Construction

Components

Control panel with protection for 2 submersible drainage pumps with threephase motor, Y/ starting.
Operation managed by the DR 2000 electronic circuit board that has the
following functions:
- pump changing at every pump start.
- working pumps changing after 30 minutes of uninterrupted operation.
- automatic operating test of each individual pump every 48 hours of
inactivity (with pumps in the automatic functioning mode).
- Pump control with signals coming from:
- 3 float switches: for starting-up and stopping pump 1, for starting-up
and stopping pump 2, for the alarms (maximum level is optional).
- 4 float switches: for starting-up pump 1, for starting up pump 2, for
stopping the pumps and for the alarms (maximum level is optional).

- Metal case.
- Line selector switch with door-locking device.
- Power line fuses.
- Auxiliary circuit fuses. - Contactors.
- Y/ timers. - Level regulator.
- DR 2000 type circuit board with microprocessor.
- Connection terminals for float switches.
- Connection terminals for thermal protectors.
- Connection terminals for water seepages probe.
- Connection terminals for the RA 100, RA 100A type remote alarm
control panel or volt free contact module.
- Cable glands.

Technical data
- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).
- Ambient temperature from -5 C to +40 C.
- Protection IP 55.

ON REQUEST:
- Volt free contact module MSP 1M - MSP 9M.
- RA 100 - RA 100A control panel for remote alarm.
- Voltmeter.
- Ammeter.

656

Control panels
QTLD 3 D FT Control panel for 3 submersible drainage pumps with three-phase motor, direct starting

Code
---

Motor
Power
kW

Type
QTLD 3D 0,55 FT
QTLD 3D 1,1 FT
QTLD 3D 1,5 FT
QTLD 3D 3 FT
QTLD 3D 4 FT
QTLD 3D 5,5 FT

0,55
0,75 - 1,1
1,5
2,2 - 3
4
5,5

400V - 3~

Current
A
1 - 1,6
1,6 - 2,5
2,5 - 4
4 - 6,5
6,3 - 10
9 - 12

Dimensions
HxBxP mm
470x390x170
470x390x170
470x390x170
470x390x170
470x390x170
470x390x170

Construction

Components

Control panel with protection for 3 submersible drainage pumps with threephase motor, direct starting.
Operation managed by the DR 3000 electronic circuit board that has the
following functions:
- changes pumps at every pump start.
- changes working pumps after 30 minutes of uninterrupted operation.
- automatic functioning test of each individual pump every 48 hours of
inactivity (with pumps in the automatic functioning mode).
- Pump control with signals coming from:
- 4 float switches: for starting-up and stopping pump, for the alarm
(maximum level is optional).
- 5 float switches: for starting-up pump, for stopping the pumps and for
the alarm (maximum level is optional).

- Metal case.
- Line selector switch with door-locking device.
- Power line fuses.
- Auxiliary circuit fuses.
- Contactors.
- Thermal relay
- DR 3000 type circuit board with microprocessor.
- Connection terminals for float switches.
- Connection terminals for the RA 100, RA 100A type remote alarm
control panel or MSP 1M volt free contact module.
- Cable glands.

ON REQUEST:
- Volt free contact module MSP 1M.
- RA 100 - RA 100A control panel for remote alarm .
- Voltmeter.
- Ammeter.

Technical data
- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).
- Ambient temperature from -5 C to +40 C. - Protection IP 55.

QTLD 3 ST FT Electric control panel for 3 drainage pumps with three-phase motor, Y/ starting
Code
---

Motor
Power
kW

Type
QTLD 3ST 4
QTLD 3ST 5,5
QTLD 3ST 7,5
QTLD 3ST 11
QTLD 3ST 15
QTLD 3ST 18,5
QTLD 3ST 22
QTLD 3ST 30B
QTLD 3ST 30A
QTLD 3ST 37
QTLD 3ST 45
QTLD 3ST 55
QTLD 3ST 75
QTLD 3ST 92

FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL
FT-RL

4
5,5
7,5
9,2 - 11
15
18,5
22
30
30
37
45
55
75
92

400V - 3~

Current
A
7 - 11
11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105
100 - 125
120 - 150
155 - 255

Dimensions
HxBxP mm
800x600x250
800x600x250
800x600x250
800x600x250
800x600x250
1000x600x250
1100x700x250
1200x800x300
1200x800x300
1400x800x400
1400x800x400
1600x800x400
1600x1000x400
1600x1000x400

Construction

Components

Control panel with protection for 3 submersible drainage pumps with threephase motor, Y/ starting.
Operation managed by the DR 3000 electronic circuit board that
incorporates the following functions:
- changes pumps at every pump start.
- changes working pumps after 30 minutes of uninterrupted operation.
- automatic functioning test of each individual pump every 48 hours of
inactivity (with pumps in the automatic functioning mode).
- Pump control with signals coming from:
- 4 float switches: for starting-up and stopping pump, for the alarm
(maximum level is optional).
- 5 float switches: for starting-up pump, for stopping the pumps and for
the alarm (maximum level is optional).

- Metal case. - Line selector switch with door-locking device.


- Power line fuses. - Auxiliary circuit fuses. - Contactors.
- Y/ timers. - Level regulator.
- DR 3000 type circuit board with microprocessor.
- Interface for DR 3000.
- Connection terminals for float switches.
- Connection terminals for thermal protectors.
- Connection terminals for water seepages probe.
- Connection terminals for the RA 100E, RA 100A type remote alarm
control panel or MSP 1M volt free contact module.
- Cable glands.

Technical data

- Mains 400V 3 ~ 10% 50 Hz (other voltages on request).


- Ambient temperature from -5 C to +40 C. - Protection IP 55.

ON REQUEST:
- Volt free contact module MSP 1M.
- RA 100 - RA 100A control panel for remote alarm .
- Voltmeter.
- Ammeter.

657

53

09/2016

SMAT
ELECTRONIC PROTECTION DEVICE FOR PUMP

Construction

Electronic device for pumps protection, the device stops the


pump in case of dry running and motor overcurrent.

Electrical connection
- To pump motor cable (Schuko plug built-in)
- To electric line socket (Schuko plug built-in)

Applications
For protection of the pump:
The device protect the pump: - against dry running;
- against overcurrent.

Operating conditions
Maximum ambient temperature max 55 C.
Single-phase mains voltage: 230 V 10%.
Frequency: 50 - 60 Hz.
Protection IP 65.
Pump motor current Minimum 3 A - Maximum 8 A.

Control Panel

min 3A max 8A
P533

230V 50 Hz

made in italy

Operation

Green Led on = Device energised

Yellow Led on = Pump running

Blinking red Led = Water shortage


Red Led on = Power surge

RESTART button =

- Acquisition motor data


- Reset after fault
658

SMAT
ELECTRONIC PROTECTION DEVICE FOR PUMP

Dimensions and weights

made in italy

50

123

min 3A max 8A
P533

230V 50 Hz

78
87

Example of installation
In order to operate, the electrical power supply of the pump must be connected to the mains.
For this reason the power supply plug of the pump must be inserted in the socket of the device which is in turn connected to the power point (see Figure).
In case of a water shortage on suction, the device will stop the pump and protect it against dry running.
This malfunctioning is indicated with the red "Failure" Led lit up.
In case of the current absorption exceeding 8 amperes, the device will stop the pump motor and protect it
against over-current.
This malfunctioning is indicated with the red "Failure" Led lit up.
To restore normal operation to the device and the system simply press the red "Restart" button.
In case of a blackout, it will automatically rearm again several seconds after the electricity returns.

min 3A max 8A
P533

230V 50 Hz

made in italy

54
659

09/2016

PMAT
PRESSURE SWITCHES FOR WATER SYSTEM APPLICATIONS

Construction
- Pressure switches for use with water in autoclave systems
- The switch ensures automatically the starting and stopping of the
electric pump according to the set pressure values
- Electric contacts: normally closed and made of brass alloy with Ag-Ni
surfacing
- Terminals with M4 screws and 8x8 mm pressure dice
- NBR rubber membrane with textile insert (food grade for PMAT 5M10, PMAT 5M/T-16, PMAT 5.5M/T-16)
- "F hydraulic connection made of galvanized steel
- Standard protection degree IP 44
- Max ambient temperature: 55C
- Tear resistant cable clamps

Technical data
2-pins

Adjustment key included

PMAT 5M-10

max
A

Pressure
range
bar

10

1-5

Differential
min
max
bar
bar
0,6
2,3

Factory
setting
bar
1,4 - 2,8

Maximum rated voltage 250V

2-pins
PMAT 5M/T-16
PMAT 5,5M/T-16
PMAT 12M/T-16

max
A

Pressure
range
bar

16
16
16

1-5
1,5 - 5,5
3 - 12

Differential
min
max
bar
bar
0,6
2,3
0,8
2,2
1,5
5

Factory
setting
bar
1,4 - 2,8
1,8 - 3
5-7

Maximum rated voltage 500V

Connection diagram

Dimensions

1~

3~

G 1/4

IP 44
10 A - 250V ~
16 A - 500V ~

IP 44
16 A - 500V ~

104

LINE
.1
34
3.5
4.9

LINE

LINE

102

65

.3
34
3.5
4.9

LINE

MOTOR

MOTOR

MOTOR

MOTOR

Diagram seeting
6

PMAT 5,5

PMAT 12

12

10

0
1
2
0
Min. Seeting
values:(bar)
cut-in (bar)
Taratura
minima

Max. Seeting
values:
cut-in (bar)
Taratura
massima
(bar)

Max. Seeting
values:
cut-in (bar)
Taratura
massima
(bar)

Max. Seeting
values:
cut-in (bar)
Taratura
massima
(bar)

PMAT 5

14

0
0
1
2
Min.
Seeting
values:(bar)
cut-in (bar)
Taratura
minima

660

2
2

Min.
Seeting
values:(bar)
cut-in (bar)
Taratura
minima

10

09/2016

ARIAMAT
AUTOMATIC AIR FEEDER

Construction

ARIAMAT

The automatic air feeder ARIAMAT controls the air cushion in the pressure vessel by replacing the air dissolved in the water at every pump start.
This device limits the number of pump starts and stops, allows a better
use of the water reserve and improves the overall performance of the
automatic pressure system.

type
AR 300E
AR 1000E
AR 2000E
Complete with connections
and 1 m polyethylene pipe

Operation
ARIAMAT operation is explained in pictures 1-2-3-4.
At the end of every cycle, ARIAMAT AR 300E, AR 1000E and AR
2000E let in the vessel 300, 1000 and 2000 cm3 of air respectively.
For a good operation of ARIAMAT it is necessary to have enough suction pressure in the pipe whilst the pumps are running.
If the pumps work under positive suction head and water falls to the
suction inlet, there will not be enough suction pressure in the suction
pipe to allow a correct operation of ARIAMAT; in this case, it is necessary to create an artificial loss in the suction pipe, by closing gradually
the gate valve when the pump is running until the water level in the
ARIAMAT starts dropping.
When a sufficient suction pressure to grant a safe ARIAMAT operation
cannot be achieved, it is recommended to feed the vessel with a compressed air system and level probes.

Materials
Component
Upper elbow
Air valve
Feeder body
Ball valve
Conical fittings
Pipe

Material
Brass
Brass
Polycarbonate
Rubber
Polyethylene
Polyethylene

Description of the supply


The ARIAMAT is normally fitted on our automatic water systems.
The supply of ARIAMAT, as a spare part to be installed by the customer,
includes:
n 1
ARIAMAT assembled with upper elbow and air valve;
m1
Polyethylene tube with ring nut and fitting for connection to the
pump suction side.

Pressure vessel capacity in litres

Pressure
in m
100

200

14/28

400

500

750

1000

1500

AR 300E

20/30

AR 300E

35/55

4.93.207.1

1) When the pump is stopped,


ARIAMAT is full of water.

4000

5000
AR 2000E

AR 1000E

AR 300E

AR 300E

3000

AR 2000E

AR 1000E

AR 2000E

AR 1000E

AR 300E

55/70

2000
AR 1000E

AR 300E

30/40

75/95

300

AR 2000E

AR 1000E

AR 2000E
The use of an air compressor is recommended.

AR 1000E

4.93.207.2

4.93.207.3

2) When starting, the pumps creates a


suction pressure which also takes the
water from ARIAMAT, allowing some
more water to come from the vessel.
The water through the ARIAMAT venturi sucks air from the upper valve.

661

3) The water level in the ARIAMAT drops until the ball valve
moves to the bottom of the ARIAMAT closing the hole of the pipe
connected to the pump. ARIAMAT
is now full of water.

4.93.207.4

4) When stopping, there is a


back-flow of water from
the vessel through the
pump, to the ARIAMAT. Air
is pushed inside the vessel.

54

09/2016

ACCESSORIES
PRESSURE GAUGES

VALVES
check valve

axial connection type

VNR 1
VNR 1 1/4
VNR 1 1/2
VNR 2

MA 0-6
MA 0-6 ABS

foot valve

MR 0-10
MR 0-12
MR 0-16

radial connection type

VDF 1
VDF 1 1/4
VDF 1 1/2
VDF 2

LEVEL PROBES

CONNECTOR
type

connection

RA5 H 92
RA5 H 105

type

G1
G1

SL 2 electrodes
SLA Assembled level probes
Cable 2x0,75 mm 2
(cable length on request)
example:

SLA 30

Assembled level probes


30 m cable length

CYLINDRICAL VESSEL

SPHERICAL VESSEL
type
SS 24

vessel with base and feet

connect. capacity
G1

type

24 l

SC 20 BP

connect. capacity
G1

20 l

BUTYL rubber diaphragm.


BUTYL rubber diaphragm.

INOX CYLINDRICAL VESSEL

INOX CYLINDRICAL VESSEL


vertical cylindrical vessel

vessel with base and feet

type

type

SCX 20

connect. capacity
G1

20 l

SCX 20 BP

BUTYL rubber diaphragm.

connect.
G1

capacity
20 l

BUTYL rubber diaphragm.

662

ACCESSORIES
KIT 1

KIT 2

Type

KIT 1A

KIT 1B

KIT 1CX

KIT 1DX

Type

Components

KIT 2A

KIT 2B

KIT 2CX

KIT 2DX

RA5 H 92

RA5 H 92

RA5 H 92

RA5 H 92

FSG 2

FYG 22

FSG 2

FYG 22

MR 0-10

MA 0-6 ABS

MR 0-10

FP 1-680

FP 1-680

FP 1-680

FP 1-680

Bend

1" M.F.

1" M.F.

1" M.F.

1" M.F.

Bend

1" F.F.

1" F.F.

1" F.F.

1" F.F.

SC 20 BP

SC 20 BP

SCX 20 BP

SCX 20 BP

Components

Connector

RA5 H 92

RA5 H 92

RA5 H 92

RA5 H 92

FSG 2

FYG 22

FSG 2

FYG 22

Pressure switch

MR 0-10

MA 0-6 ABS

MR 0-10

Pressure gauge MA 0-6 ABS

SS 24

SCX 20

SCX 20

Flexible hose

Pressure switch

Pressure gauge MA 0-6 ABS


Vessel

SS 24

Connector

Vessel

CE 97/23 PED APPROVED MEMBRANE VESSELS


(Membrane vessels)

CE 97/23 PED APPROVED PRESSURE VESSELS


(Air tanks)
Hot galvanized vessels
D

DN

DN

TYPE
100- 5
200- 5
300- 8
500- 8
500- 12
800- 8
1000- 8
1000- 12
1500- 5
1500- 8
2000- 8
2000- 12
3000- 8
3000- 12
4000- 8
4000- 12
5000- 8
5000- 12

Dimensions
D x H mm
400 x 1020
450 x 1440
550 x 1500
650 x 1820
600 x 2000
800 x 1900
800 x 2150
800 x 2300
950 x 2500
950 x 2500
1100 x 2570
1000 x 2780
1250 x 2930
1200 x 2930
1450 x 3090
1450 x 3090
1450 x 3590
1450 x 3590

weigth

Pressure Dimensions

DN
kg
G1
32
G1
48
G 1 1/2
65
G2
105
G2
120
G2
145
G 2 1/2 160
G 2 1/2 203
G2
190
G2
255
G 2 1/2 330
G 2 1/2 387
G3
470
G3
596
G3
620
G3
880
G4
715
G4
1020

TYPE

4.93.122.7

TYPE

4.93.122.7

D x H mm

10
10
10
10
10
10
10
10

388 x 840
G1
430 x 960
G1
460 x 990
G1
590 x 1120 G 1 1/2
640 x 1230 G 1 1/2
750 x 1540
G2
750 x 1850
G2
800 x 2180
G2

SM 60 V
SM 80 V
SM 100 V
SM 200 V
SM 300 V
SM 500 V
SM 750 V
SM 1000 V

kg
weight

bar

D x H mm

DN

kg

10
10
10
10
10
10
10
10

382 x 845
450 x 850
450 x 950
550 x 1255
630 x 1405
780 x 1550
780 x 1940
980 x 1970

G1
G1
G1
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G2

EPDM diaphragm
Temperature -10 +100 C
With safety valve and pressure gauge 016 bar

663

DN

Pressure Dimensions

The vessels are suitable for water up to 50 C


They are all approved at manufacturers premises and are supplied
complete with safety valve, testedvpressure gauge and fittings.

SM 60 C
SM 80 C
SM 100 C
SM 200 C
SM 300 C
SM 500 C
SM 750 C
SM 1000 C

weight

bar

54

ACCESSORIES
FLOAT SWITCH

FLEXIBLE HOSE
tipo

type

INTGALL
(cable 2,5 m)

FP 1-630
FP 1-680

SYSTEM FOR AIR INTAKE

d x length
G 1 X 630
G 1 X 680

SYSTEM FOR AIR INTAKE


Kit of level probes
with solenoid valve

Kit of level probes


with compressor

MOTOR COVER PROTECTION KIT

Type

Motor
kW

157 cover

0,75 2,2

180 cover

34

223 cover

5,5 7,5

263 cover

9,2 18,5

314 cover

22 30

The kit includes: 1 Plate


1 Cilinder
2 Screws
1 Washer

664

09/2016

Technical appendix
How to select a centrifugal pump
The selection of a centrifugal pump should be made according to the actual
characteristics and conditions of the plant.
The required data for a correct selection are the following:

0 U.S. g.p.m. 50

100

150

200

A 200

50

B 188

160
50

55

60 62

64 65

40

140
66%
65 64 120

Hmt = Hg + pc mt fluid column

0 Q m3/h
0 l/min
0

Hg = geometric head inlet (Hga) + geometric head outlet (Hgp)


pc = sum of head loss of the plant calculated from the following data:

l/s 2

10
200

20

30
400

40
600

10

12

12

14

100
60
1000
16

A 15

10

P kW

50
800

10

6
4

P HP

30

20
15

10
2

NPSH ft

NPSH m

- Diameter, length and material of the suction and delivery piping (see table
no. 1 page 674).
- Number and type of elbows in the piping and hydraulic accessories such as
foot valves, gate valves, non-return valves and strainers etc. (see table no. 2
page 674).
- Type, temperature, viscosity and density of the fluid (if different from that of
water)

180

H ft

Total manometric head Hmt


It is considered as the sum between the geometric head exsisting between
the fluid levels and the head loss due to frictions from the fluid passage in
the pipework, into the pump and relevant hydraulic accessories.
The expression is the following:

250

NM 50/20

Hm

Flow Q
Quantity of fluid delivered by the pump in the unit of time, generally expressed
in m3/h.

60

5
Pay attention to the manometric suction lift Hga + pc asp, which should be
0
0
compared with the suction capability of the pump.
72.020
0 Q m3/h 10
20
30
40
50
60
This suction capability or NPSHr is defined as net positve suction head and its
value is obtained from a curve in accordance with the flow.
For this purpose, once the pump has been selected according to the required flow and head, where possible at the middle of the curve, check the
following simplified formula:

10 mt Hga - pc asp. > NPSH required + 0.5 mt


Hga is the difference in height between the free surface of the water, and its value is negative if the pump is installed above the free water surface.
pc asp is the sum of the remaining distributed (piping) and concentrate (valves, bends, etc.) suction head loss
If the final result is negative, it is often possible to adjust flow via a gate valve on the delivery side, in order to restore correct pump operating conditions, without cavitation.
For fluid temperatures higher than the average of about 20C, the pumps loose their suction capability.
Such changes, referred to pumps with suction capability of 7 meter at normal temperature, are shown on table no. 3 page 675.

CHARACTERISTIC DATA OF THE PUMPS


Once the flow (Q) and total manometric head of the installation (Hmt) are established, the pump absorbed power N should be calculated through the
following formula:

where:

N = Q x H x in kW
367 x p

Q = Flow in m3/h
H = Head in mt
= Fluid density (water = 1 kg/dm3)
p = Pump efficiency (Ex. Pump efficiency 68% = p = 0.68)
The pumps are normally connected to electric motors, which operate at 2900 rpm with 2-pole motors at 50Hz, or at 1450 rpm with 4-pole motors at 50Hz.
However, they can run at any other speed within the limits of design.
Therefore, when changing the number of revolutions, the pump performance will change according to the following rules:
The flow in proportion to the number of revolutions: Q2 = Q1 x

n2
n1

The head, in proportion to the square of the number of revolutions: H2 = H1 x

( nn21 )

The absorbed power, in proportion to the cube of the number of revolutions: N2 = N1 x

665

( nn21 )

55

How to select a centrifugal pump


Calculation example for the selection of a centrifugal pump
Case A

Istallation data

A) Operation with suction lift


- Q (Flow) = 42 m3/h
- Hga (geometric head inlet) = 3,5 m
- Hgp (geometric head outlet) = 39 m
- 5 m DN 100 mm diameter suction pipe complete with 1 elbow
and 1 foot valve
- 70 m DN 80 mm diameter delivery pipe with 1 non-return valve, 1
gate valve and 3 sweep elbows
Hg = Hgp + Hga = 39 + 3,5 = 42,5 m Geometric head of the installation

Hgp

pc = total head loss

80 Pipe
70 m Length

Hg

Suction side:
5 m 100 piping
1 Elbows
1 Foot valve

pc = 0,12 m
pc = 0,045 m
pc = 0,46 m

Delivery side:
70 m 80 pipe
1 Non-return valve
1 Gate valve
3 Elbows

pc = 5,25 m
pc = 0,5 m
pc = 0,05 m
pc = 0,09 m

Total

pc = 6,5 m.

Hga
4.93.180.1

100 Pipe
5 m Length

Considering that the calculation has been made for new pipes, an
increase of 15/20% is to be applied for ageing etc. Therefore the
total head loss p amounts to about 8 m.
Therefore, the total manometric head which the pump must achieve is:

Foot valve

Hmt = Hg + p = Hgp + Hga + pc = 39 + 3,5 + 8 = 50,5 m total.


The pump type NM 50/20AE can be chosen (see pump diagram)

Case B

Istallation data

- Q (Flow) = 42 m3/h
- Hga (geometric head inlet) = 3,5 m
- Hgp (geometric head outlet) = 39 m
- 5 m DN 100 mm diameter suction pipe complete with 1 gate valve
and 1 foot valve
- 70 m DN 80 mm diameter delivery pipe with 1 non-return valve, 1
gate valve and 3 sweep elbows

B) Operation under positive suction head

Hg

Hg = Hgp - Hga = 39 - 3,5 = 35,5 m Geometric head of the installation


pc = total head loss
Suction side:
5 m 100 piping
1 Non-return valve
1 Gate valve

Hgp
80 Pipe
70 m Length

pc = 0,12 m
pc = 0,5 m
pc = 0,05 m

Hga

Delivery side:
70 m 80 pipe
1 Non-return valve
1 Gate valve
3 Elbows

pc = 5,25 m
pc = 0,5 m
pc = 0,05 m
pc = 0,09 m

Total

pc = 6,5 m

4.93.100

100 Pipe
5 m Length

Considering that the calculation has been made for new pipes, an
increase of 15/20% is to be applied for ageing etc. Therefore the
total head loss pc amount to about 8 m.
Therefore, the total manometric head which the pump must achieve is:
Hmt = Hg + p = Hgp - Hga + pc = 39 - 3,5 + 8 = 43,5 m total.
The pump type NM 50/20BE can be chosen (see pump diagram)

666

How to select a centrifugal pump

ACCESSORIES FOR WATER SUPPLY


Foot valve with strainer - Sealing member installed on the lower end of the suction pipe. It prevents the water coming out from the
piping and pump at every plant stop. It must be always immersed in the fluid at an installation depth which allows a perfect operation
without cavitation.
It is a good rule to also install a float switch to automatically stop the pump when the water goes below a fixed level.
Non-return valve - It must be installed on the pump delivery port to avoid reflux in case of a sudden stop of the plant. It is recommended using a type fitted with an inner return spring and with ogive shutter, as this will help to diminish water hammering.
Gate valve - The installation of a gate valve is very important. In addition to allowing the pump to be dissasembled without emptying
the plant, it is used to start the plant and to adjust the flow.

PIPING
The piping must be selected in-line with the water velocity which is recommended to be 1.5 meter per second on the suction side and
3 meter per second on the delivery side. The calculation of the suction piping must be carefully checked so as to avoid the maximum
head loss and allow the pumps maximum suction capability. The piping must be perfectly tight and have no counterslopes towards the
pump port, so to avoid the development or entrapment of air bubbles or pockets.
All the piping must be secured to rests, so that they will not weigh on the pump ports.

Problems at the pump


Faults

Possible causes

Jammed pump

This may happen after periods of inactivity due to inner oxidation.


To release smaller sized monobloc electropumps use a screwdriver at the notch on the back part
of the shaft.
For the larger sizes, turn on the shaft or the flexible coupling

Pumps which do not prime

Pump and/or suction pipe with air entraped.


Uncomplete priming or totally unprimed.
Possible air entering from taps, drain or fill plugs, joints or stuffing box
Foot valve not fully immersed in the fluid or obstructed by deposits.
Suction lift too high compared with the capability of the pump.
Wrong direction of rotation
Wrong number of revolutions

Insufficient flow

Piping and accessories of too small a diameter which cause too high head loss.
Jammed impeller with presence of debris in the vanes.
Corroded or broken impeller
Impeller wear rings and/or pump casing worn by abrasion.
Gas presence in the water, or too high fluid viscosity in case of fluids different from water.

Noise and vibrations in the


pump

Unbalanced rotary part or worn ball bearings.


Pump and piping not properly secured.
Too low flow rate for the selected pump
Operation with cavitation

Overloaded motor

Pump characteristics higher than those of the plant


Fixed and rotary parts in contact tending to seize owing to a lack of lubrication
Too high rotation speed
Wrong mains supply
Poor unit allignement
Fluid with too higher density than the design

667

55

How to select a Pressure Boosting Sets


Choosing a pressure-boosting set
Required quantity of water
The public water-supply system is normally capable of supplying water at an adequate pressure and capacity level to the various outlets connected to it.
In those cases where a water-supply system is non-existent or insufficient for correct operation of the various facilities, a pressure-boosting system has
to be installed to ensure an acceptable level of pressure and capacity also at the outlets in the most unfavourable positions.
The size of the water-supply unit is determined according to the quantity of water and pressure required.

Residential buildings
The main data needed for calculation of the quantity of water required is given in the following list:
- the number of outlets
- consumption per each type of outlet (Tab.1)
- the contemporaneity factor (Fc)

Table 1: Maximum consumption at points of demand


Qu. delivered
Outlet
(l/min)
Sink
10
Wash-basin
10
Bath/whirlpool tub
18
Shower
WC - flush-tank type
WC - fast-feed type

12
7
90

Bidet
Washing machine
Kitchen sink

6
12
12

Dishwasher
Outlet w/ 1/2 tap
Outlet w/ 3/4 tap

8
20
25

The maximum theoretical requirement is given by the sum of the quantities of water delivered to the various outlets of an appartment multiplied by the
number of appartments. In practice, it is generally found that only some of the outlets are used simultaneously.
The contemporaneity factor (Fc) allows for definition of the real maximum delivery that may be required by the outlets.
The following formulae are used to calculate the Fc factor. The value Ut is the total number of outlets (the number of outlets in an appartment multiplied by the number of appartments).

Appartments with 1 toilet - flush-type tank:

Fc =

Appartments with 1 toilet - fast-feed type:

Fc =

Appartments with 2 toilets - flush-type tank: Fc =

Appartments with 2 toilets - fast-feed type:

Fc =

V0,85 x Ut
1

V0,7 x Ut
1

V1,1 x Ut
1

V0,83 x Ut

Diagram A gives the values of actual delivery, which depend on the number of appartments connected to the water-supply system. Seven outlets are
hypothesized for one-bathroom appartments and ten outlets for two-bathroom appartments.

Non-residential buildings
For calculation of quantities of water required, the following types of building are considered:
- offices
- shopping centres
- hospitals
- hotels
These buldings require quantities of water greater than those needed in residential buildings.
Diagram B shows the values of actual delivery for the main types of building. The values are based on hypothetical numbers of persons present in
these buildings.
These values offer a guideline and may vary in accordance with particular requirements of projects.

668

How to select a Pressure Boosting Sets


Choosing a pressure-boosting set

500
400

A Consumption in residential buildings

300
200

Flats number
NR. Appartamenti
- Flats number

100

50
40
30
20

10

5
4
3
2

Q m3/h

9 10

20

30

40

50

100

150
72.850/1

1 Appartamenti con 1 bagno, wc a cassetta


2 Appartamenti con 2 bagni, wc a cassetta
3 Appartamenti con 1 bagno, wc a passo rapido
4 Appartamenti con 2 bagni, wc a passo rapido

2500

1 Appartments with one toilet, flush-tank type


2 Appartments with two toilets, flush-tank type
3 Appartments with one toilet, fast-feed type
4 Appartments with two toilets, fast-feed type

B Consumption in non-residential buildings

Number of persons present in building


Numero presenze - Number of persons present in building

2000

1000

500
400
300

200

100

50

2 Q m3/h

A Uffici
B Centri commerciali
C Strutture ospedaliere
D Hotels

9 10

20

30

40

50

100

150

200
72.850/2

A Offices
B Shopping centres
C Hospitals
D Hotels

55
669

How to select a Pressure Boosting Sets


Choosing a pressure-boosting set
Delivery head
The outlet pressure required for proper operation of electrical appliances must not be lower than 1.5 bar and not greater then 4-5 bar.
When the pressure level is insufficient and to such a degree that it impedes operation of domestic appliances, a pressure-boosting system must be
installed to ensure adequate pressure also at the more unfavourablylocated points of demand.
The values to consider for calculation of the pressure level are the following:
- Hg the geodetic head between the pressure-boosting unit and the highest outlet.
- Ha the suction lift.
- Pi the initial pressure (or positive suction head).
- Pr the minimum residual pressure at the highest outlet (normally 1.5 bar).
- Pc the system head loss.
- p the difference in pressure between starting and stopping pumps.

Pc

Pc

Pr

Pr

Total
H
H totale
Hg+Pr+Pc-Pi+p

Hg

Hg

H
HTotal
totale
Ha+Hg+Pr+Pc+p

Pi

Ha

When the pumps draw water from a well, the dynamic height difference (Ha), when pumps are operating, should not exceed 4 m.
A greater suction head or erroneous sizing of the suction pipe may cause improper operation of the pumps - e.g. cavitation and priming loss.
The pumps are installed with a positive suction head when they are connected to a raised tank or a pressurized primary collection tank.
The pumps therefore have an initial pressure at the suction port which can vary from 0.1 bar (suction with a collection tank) to 2-3 bar (with suction from
a pressurized primary collection tank).
When choosing a pressure-boosting system, the positive value of the initial pressure (Pi) must be considered as a value to be subtracted from the height (Hg).
The system head loss (Pc) are given by the sum of the losses of the pipes (including the suction pipe) added to the losses due to gate valves, nonreturn valves, water purifiers, counters, filters, elbows etc.
Head loss in the tubes, caused by the friction of the water against the inner surface of the pipelines, may be quantified as 0.5 m per floor in the case of
new systems and 1 m per floor in the case of old systems.
To avoid pressure levels greater than 4-5 bar arriving at outlets on the lower floors of apartment blocks and other buildings with a height greater than
30 m (about 10 floors), pressure reducers must be installed at the offtake point of the lower floors or otherwise two pressure-boosting units can be
installed: one for the lower floors and one for the upper floors.

670

How to select a Pressure Boosting Sets


Surge tanks
The purpose of surge tanks is to retain a quantity of water, under pressure, thus avoiding continuous pump starts, as water is demanded.
The selection of the vessel must be made in-line with the pump flow and
pressure and number of starts allowed by the motor.
For water pressure units with more than one pump, the selection of the
vessel should refer to the data for one pump only.

CE 97/23 PED APPROVED PRESSURE VESSELS


(Air tanks)
Hot galvanized vessels

The surge vessel may be of the following type:


a) Air cushion vessels
b) Membrane vessels
Air cushion vessels
In this type of vessels the air and water are in contact with each other.
This will therefore result in a decrease of air as it dissolves into the
water.
The installation will therefore require an automatic air feed (Ariamat air
feeder, compressor or auto valve connected to existing compressed air
network).
Air cushion vessels are normally manufactured from hot galvanized
sheet steel, with rated pressures from 6 to 12 bar and capacity from 100
to 5000 ltrs, complete with safety valves, pressure gauge and level indicator.

DN

DN

Membrane vessels
These vessels are fitted with an inner membrane separating the water
and air. When installed , they must be pre-charged at a pressure in-line
with the pressure switch settings.
Calculation to size an air cushion vessel.
Vt = 1.25 x Qm x (P1 +10)
4 x Z x (P1 - P2)
where:
Vt = Total volume of air cushion vessel in m3
Qm = Average pump flow in m3
P1 = Maximum set pressure of pressure switch
P2 = Minimum set pressure of pressure switch
Z
= Maximum number of starts/hour allowed by the motor
(see table).

TYPE

Dimensions
D x H mm

DN

Weight
kg

100- 5

400 x 1020

G1

32

200- 5

450 x 1440

G1

48

300- 8

550 x 1500

G 1 1/2

65

500- 8

650 x 1820

G2

105

500- 12

600 x 2000

G2

120

800- 8

800 x 1900

G2

145

1000- 8

800 x 2150

G 2 1/2

160

1000- 12

800 x 2300

G 2 1/2

203

1500- 5

950 x 2500

G2

190

1500- 8

950 x 2500

G2

255

2000- 8 1100 x 2570

G 2 1/2

330

2000- 12 1000 x 2780

G 2 1/2

387

3000- 8 1250 x 2930

G3

470

3000- 12 1200 x 2930

G3

596

4000- 8 1450 x 3090

G3

620

4000- 12 1450 x 3090

G3

880

5000- 8 1450 x 3590

G4

715

5000- 12 1450 x 3590

G4

1020

The vessels are suitable for water up to 50 C


They are all approved at manufacturers premises and are supplied complete with safety valve, tested pressure gauge and fittings.

Qm flow is the average between the flow at starting pressure


(Q min) and the flow at stop pressure (Q max):
Qm = Qmin + Qmax (m3/h)
2
Exemple: Pump MXV 40-807
P1 = 70 m
P2 = 50 m
Qm = 9,45 m3/h
Z = 23 starts/hour

CE 97/23 PED APPROVED MEMBRANE VESSELS


Pressure Dimensions

Vt = 1.25 x 9,45 x (70 +10) = 0,514 m3


4 x 23 x (70 - 50)
From the calculation, it would result in the selection of a 500 litre vessel.

TYPE

Calculation to size a membrane vessel


1
Vt = Qm x
4xZ
1 - (P2 - 2)
P1
where:
Vt = Total volume of air cushion vessel in m3
Qm = Average pump flow in m3
P1 = Maximum set pressure of pressure switch
P2 = Minimum set pressure of pressure switch
Z
= Maximum number of starts/hour allowed by the motor
(see table)

4.93.122.7

TYPE

4.93.122.7

1
Vt = 9,45 x
= 0,327 m3
4 x 23
1 - (50 - 2)
70
From the calculation it will result in the selection of a 300 litre membrane
vessel.

bar

D x H mm

10
10
10
10
10
10
10
10

388 x 840
G1
430 x 960
G1
460 x 990
G1
590 x 1120 G 1 1/2
640 x 1230 G 1 1/2
750 x 1540
G2
750 x 1850
G2
800 x 2180
G2

SM 60 V
SM 80 V
SM 100 V
SM 200 V
SM 300 V
SM 500 V
SM 750 V
SM 1000 V

kg
weight

bar

D x H mm

DN

kg

10
10
10
10
10
10
10
10

382 x 845
450 x 850
450 x 950
550 x 1255
630 x 1405
780 x 1550
780 x 1940
980 x 1970

G1
G1
G1
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/2
G2

EPDM diaphragm
Temperature -10 +100 C
With safety valve and pressure gauge 016 bar

671

DN

Pressure Dimensions

Exemple: Pump MXV 40-807


P1 = 70 m
P2 = 50 m
Qm = 9,45 m3/h
Z = 23 starts/hour

SM 60 C
SM 80 C
SM 100 C
SM 200 C
SM 300 C
SM 500 C
SM 750 C
SM 1000 C

weight

55

How to select a centrifugal pump


Number of starts/hour allowed for CALPEDA motors
Rated motor power output

kW 0,25 0,37 0,55 0,75

Max. number of starts/hour

59

51

44

38

1,1

1,5

2,2

5,5

7,5

9,2

11

15

18,5

22

30

37

45

35

30

25

23

20

18

16

15

14

12

11

10

360

420

The number of starts/hour mentioned in the table is approximate.


The maximum admissible starts/hour depends on the pump model and are mentioned in the original operating manual.

Table no. 1
Head loss in m for steel pipes
Q m3/h

12

18

24

30

36

42

48

mm Q l/min

16

50

100

150

200

300

400

500

600

700

800 1000 1500 2000 3000 4000 5000 6000 7000

75

Pipe
Tubo
G

60

90

120

180

240

300

DN 25

2,7

21

80

0,6

1,7

3,5

G 1 1/4 DN 32

0,7

5,5

22

47

0,35

2,1

3,1

G 1 1/2 DN 40

1,8

14

23

50

90

0,7

1,35

1,9

2,5

3,8

5,2

G2

DN 50

0,5

2,2

17

28

45

62

0,4

0,8

1,25

1,5

2,5

3,2

4,1

G 2 1/2 DN 65

0,6

1,2

2,1

4,2

12

17

22

28

45

0,5

0,75

1,4

2,5

3,4

1,6

2,8

4,2

6,5

7,5

10,5

15

32

50

2,1

2,6

3,3

4,9

G1

DN 80

HL
v

0,8
0,7

0,95

1,25

1,6

0,55

0,9

1,4

2,4

3,5

11

20

40

m/100m
m/s
DN 125

0,6

0,8

1,1

1,25

1,4

1,6

3,2

0,9

1,2

1,8

6,5

15

23

0,95

1,1

1,4

2,7

5,2

DN 150

0,6

1,5

2,5

14

20

0,9

1,4

1,7

2,7

3,5

4,8

5,6

DN 200

0,4

0,6

1,3

3,5

4,6

6,5

0,8

1,6

2,6

3,5

0,7

1,1

1,6

DN 100

DN 250

0,4
1

1,3

1,6

2,3

DN 300

0,3

0,45

0,7

0,9

0,9

1,25

1,4

1,6

Q Flow.

HL Head loss, m per 100 m.

v = Flow velocity: max 1,5 m/s for suction and 3 m/s for delivery.

Table no. 2
Head loss in cm for bends, gate valves, foot valves and check valves

= 90 sweep elbow
R

Elbows
Water
flow
velocity

= 30

= 40

= 60

= 80

= 90

0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0

0,43
0,67
0,97
1,35
1,7
2,2
2,7
6,0
11
17
25
33
43
55
67

0,52
0,81
1,2
1,65
2,1
2,7
3,3
7,3
14
21
30
40
52
67
82

0,71
1,1
1,6
2,2
2,8
3,6
4,5
10
18
28
41
55
70
90
110

1,0
1,6
2,3
3,2
4,0
5,2
6,4
14
26
40
60
78
100
130
160

1,2
1,9
2,8
3,9
4,8
6,2
7,6
17
31
48
70
93
120
160
190

Foot
valves

Check
valves

0,23
0,37
0,52
0,70
0,95
1,20
1,45
3,3
5,8
9,1
13
18
23
37
52

32
33
34
35
36
37
38
47
61
78
100
123
150
190
220

31
32
32
32
33
34
35
40
48
58
71
85
100
120
140

d
d
d
d
= 0,4
= 0,6
= 0,8
R
R
R

m/sec.

Gate
valves

0,11
0,18
0,25
0,34
0,45
0,57
0,7
1,6
2,8
4,4
6,3
8,5
11
14
18

0,13
0,21
0,29
0,40
0,53
0,67
0,82
1,9
3,3
5,2
7,4
10
13
21
29

672

0,16
0,26
0,36
0,48
0,64
0,82
1,0
2,3
4,0
6,3
9
12
16
26
36

d
=1
R

d
= 1,5
R

0,23
0,37
0,52
0,70
0,93
1,18
1,45
3,3
5,8
9,1
13
18
23
37
52

0,43
0,67
0,97
1,35
1,7
2,2
2,7
6
11
17
25
33
42
55
67

How to select a centrifugal pump


Table no. 3
Diagram of manometric suction head with water up to 100 C

POSITIVE SUCTION HEAD


(mwc)

WATER TEMPERATURE IN DEGREES CELCIUS


5

10

20

40

30

50

60

70

80

90

100

110

60

70

80

90

100

110

4
3
2
1
0
1
2

MANOMETRIC SUCTION LIFT


(mwc)

3
4
5
6

PRAC

TI C A

U
LC

E
RV

7
8
9

THEOR

CU
TIC A L

RVE

10
11

10

20

30

40

50

WATER TEMPERATURE IN DEGREES CELCIUS

Diagram referred to pumps with manometric suction head of 7 mwc. at 20 C

55
673

Technical appendix
EFFICIENCY OF ELECTRIC MOTORS

Directive of the European Parliament COMMISSION REGULATION (EC) No 640/2009


Having regard to Directive 2005/32/EC of the European Parliament establishing a
framework for the setting of ecodesign requirements for energy- related products, it
specifies the time and the efficiency levels that motors sold in the European market will
have to comply.

This Regulation shall apply to:


electric single speed motor, three-phase 50 Hz or 50/60 Hz, squirrel cage induction motor
that:
-has 2 to 6 poles,
-has a rated voltage of UN up to 1 000 V,
-has a rated output PN between 0,75 kW and 375 kW,
-is rated on the basis of continuous duty operation.

This Regulation shall not apply to:


a) motors designed to operate wholly immersed in a liquid;
b) motors completely integrated into a product (for example gear, pump, fan or compressor) of which the energyperformance
cannot be tested independently from theproduct;
c) motors specifically designed to operate:
- at altitudes exceeding 4000 metres above sea-level;
- where ambient air temperatures exceed 60 C;
- in maximum operating temperature above 400 C;
- where ambient air temperatures are less than -30 C for any motor or less than 0 C for a motor with air cooling;
- where the water coolant temperature at the inlet to a product is less than 0 C or exceeding 32 C;
- in potentially explosive atmospheres as defined in Directive 94/9/EC of the European Parliament and ofthe Council.
d) brake motors.

Each ecodesign requirement shall apply in accordance with thefollowing timetable:


1) from 16 June 2011:
motors shall not be less efficient than the IE2 efficiency level;

a
i
Energ e

2) from 1 January 2015:


motors with a rated output of 7,5-375 kW shall not be less efficient than the IE3
efficiency level or meet the IE2 efficiency level, and be equipped with avariable speed
drive.

IE4
IE3

from 01/01/2017

IE2**
IE3

3) from 1 January 2017:


all motors with a rated output of 0,75-375 kW shall not be less efficient than the IE3
efficiency level or meet the IE2 efficiency, and be equipped with avariable speed drive.

* IE2 up to 7,5 kW from 7,5 up to 375 kW shall be equipped with avariable speed drive
** IE2 from 0,75 up to 375 kW shall be equipped with a variable speed drive
674

from 01/01/2015
up to 31/12/2016

IE2*

IE2

EFF1

IE1

EFF2
EFF3

from 16/06/2011
up to 31/12/2014

up to
16/06/2011

Technical appendix
EFFICIENCY OF ELECTRIC MOTORS
Summary table of the levels of efficiency as expected in IEC 60034-30
100
95

Efficiency %

90

IE3
IE2
IE1

85
80
75
70

10

20

30

40

50

60

70

80

90

PN kW

2-pole

4-pole

Rated power
output
kW
kW

IE1

IE2

IE3

0.75
1.1
1.5
1.8
2.2
3
4
4.4
5.5
7.5
9.2
11
15
18.5
22
30
37
45
55
75
90

72.1
75.0
77.2
78.4
79.7
81.5
83.1
83.6
84.7
86.0
86.9
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93.0

77.4
79.6
81.3
82.2
83.2
84.6
85.8
86.2
87.0
88.1
88.8
89.4
90.3
90.9
91.3
92.0
92.5
92.9
93.2
93.8
94.1

80.7
82.7
84.2
85.0
85.9
87.1
88.1
88.4
89.2
90.1
90.7
91.2
91.9
92.4
92.7
93.3
93.7
94.0
94.3
94.7
95.0

Efficiency %

Rated power
output
kW
kW

IE1

IE2

IE3

0.75
1.1
1.5
2.2
3
4
5.5
7.5
9.2
11
15
18.5
22
30
37
45
55
75
90

72.1
75.0
77.2
79.7
81.5
83.1
84.7
86.0
86.9
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93.0

79.6
81.4
82.8
84.3
85.5
86.6
87.7
88.7
89.3
89.8
90.6
91.2
91.6
92.3
92.7
93.1
93.5
94.0
94.2

82.5
84.1
85.3
86.7
87.7
88.6
89.6
90.4
91.0
91.4
92.1
92.6
93.0
93.6
93.9
94.2
94.6
95.0
95.2

Efficiency %

55
675

EEI < 0,23


EEI < 0,27
0,27 < EEI < 0,4
0,4 < EEI < 0,6
0,6 < EEI < 0,8
0,8 < EEI < 1,0
1,0 < EEI < 1,2

2015
2013
A
B
C
D
E

Technical appendix
CALPEDA MOTORS FEATURES
2-pole
2 poli
Motore
per
Motor for
MXV
pompe
pump
MXV

Motore
per
Motor for
pompe
monoblock
pump
monoblocco

M80V1-0.75T
M80V1-1.1T
M90V1-1.5T
M90V1-2.2T
M100V1-3T
M112V1-4T
M132V1-5.5T
M132V1-7.5T
M160V1-11T
M160V1-15T
M160V1-18.5T
M180V1-22T

71
80
71
80
80
80
80
90
90
112
112
132
132
132
132
160

Rated
power
Potenza
output
nominale
PN
kW
HP
0,75
1
0,75
1
1,1
1,5
1,1
1,5
1,5
2
1,8
2,5
2,2
3
3
4
4
5,5
5,5
7,5
7,5
10
9,2
12,5
11
15
15
20
18,5
25
22
30

Rated Frequenza
Frquence Velocit
Rotationdi Fattore
Powerdi
Corrente
current nominale rotazione
speed
factor
nominale
potenza
400 V
A
Hz
R.P.M.
cos
2,2
50
2900
0,76
1,9
50
2900
0,75
2,6
50
2900
0,77
3
50
2900
0,75
4,3
50
2900
0,75
4,3
50
2900
0,77
5,5
50
2900
0,81
6,6
50
2900
0,83
9,6
50
2900
0,79
10,9
50
2900
0,84
14,3
50
2900
0,83
18,5
50
2900
0,82
21,5
50
2900
0,85
27,3
50
2900
0,87
34
50
2900
0,90
41
50
2900
0,88

Rated
power
Potenza
output
nominale
PN
kW
HP
0.75
1
1.1
1.5
1.5
2
2.2
3
3
4
4
5.5
5.5
7.5
7.5
10
9.2
12.5
11
15
15
20

Rated Frequenza
Frquence Velocit
Rotationdi Fattore
Powerdi
Corrente
current nominale rotazione
speed
factor
nominale
potenza
400 V
A
Hz
R.P.M.
cos
1.9
50
1450
0.76
2.9
50
1450
0.77
3.5
50
1450
0.77
5
50
1450
0.81
6.4
50
1450
0.79
8.3
50
1450
0.83
12.5
50
1450
0.83
16
50
1450
0.81
19.0
50
1450
0.82
22.5
50
1450
0.82
29
50
1450
0.83

Efficiency
Efficienza

100%
77,4
77,4
80
79,6
81,3
82,2
83,2
85
85,8
89,2
90,1
90,7
91,2
91,9
92,4
92,7

75%
77,8
76,2
80,1
79,2
81,5
82,7
84,7
86
86,1
90,1
90,9
91
91,7
92
93,3
92,7

Efficiency
indice
class
efficienza
50%
74,6
72
77,8
76,1
79,3
80,6
82,8
85,3
84,7
89,9
90,6
89,8
91,1
90,7
93,4
91,5

IA
IN
3,9
5,8
7,1
5,1
5,5
9,1
7,1
8,2
7,6
9,1
9,1
8,2
8,5
9,5
9,4
10,7

CA
CN
2,6
3,2
4,5
3,2
3,5
5,4
4,4
4,4
3,9
3,1
3,2
3,2
3,4
4,3
3,3
3,6

IE
IE2-77.4
IE2-77.4
IE2-79.6
IE2-79.6
IE2-81.3
IE2-82.2
IE2-83.2
IE2-84.6
IE2-85.8
IE3-89.2
IE3-90,1
IE3-90.7
IE3-91.2
IE3-91.9
IE3-92.4
IE3-92.7

4-pole
4 poli
Motore
per
Motor for
monoblock
pompe
pump
monoblocco
80
80
90
90
112
112
132
132
132
160
160

Efficiency
Efficienza

100%
79.6
81.4
82.8
84.3
85.5
86.8
87.7
88.7
89.3
89.8
90.6

75%
79.9
81.9
82.7
85.1
85.9
87.1
88.0
88.8
89.2
89.8
91.3

Efficiency
indice
class
efficienza
50%
77.2
79.6
80.0
83.8
84.7
86.0
86.4
87.3
87.2
88.4
90.9

NAMEPLATE

IA
IN
5.5
5.9
7.4
7.2
5.8
7.2
8.2
8.1
8.4
8.5
9.0

CA
CN
2.8
2.7
3.7
3.4
2.6
3.2
2.3
2.2
2.8
3.6
3.6

IE
IE2-79.6
IE2-81.4
IE2-82.8
IE2-84.3
IE2-85.5
IE2-86.6
IE2-87.7
IE2-88.7
IE2-89.3
IE2-89.8
IE2-90.6

Example plate motor

The legislation requires that a nameplate is fitted detailing the following


data; the class of motor efficiency (IE1 or IE2 or IE3), the rated power,
and the value of the performance with 100% efficiency at full load, 75%
load and 50 % load.

5,5kW (7,5Hp)

Example of CALPEDA nemeplate:

400/690Y V3~50Hz 10,8 / 6,2 A


n 2900/min S1 l.cl. F

the legend describes the parameters and values shown on the


nameplate.

MONTORSO

V
400
400
400

VICENZA

% cos
100 0,84
75 0,78
50 0,67
IEC 60034-1

DISPOSAL:
This product or parts of it must be disposed of in anenvironmentally
sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact your local Calpeda representative.

676

Made in Italy

0705158995

87,5
88,1
87,4

45kg
IP 54

IE2-87

Efficiency class
Rotation speed rpm
Protection
Operation Duty / Insul. class
Weight
Supply voltage
Frquence/Nom. motor current
Rated power

Technical appendix
EFFICIENCY OF CIRCULATORS

Directive of the European Parliament COMMISSION REGULATION (EC)


No 641/2009
With the Eco-design Directive of Energy Using Products (ErP Directive Energyrelated Products) the European Union wants to improve the design of equipment that
consume significant energy (e.g. televisions, refrigerators, washing machines, boilers,
pumps, motors etc.) to improve eco-design providing environmental sustainability,
reducing negative environmental impact as the consequence of production, use and
disposal of products.
The objective of the Directive is to force manufacturers and importers to produce and
distribute products with high energy efficiency, and reduced carbon output.
The criteria for eco-design will be an integral part of the declaration of conformity (CE),
which is a necessary requirement/mark for products being sold in the EU.

This Regulation shall apply to:


Stand-alone* or integrated** circulators with the motor immersed in the pumped
medium, with hydraulic power from 1 up to 2500 W, designed for use in heating
systems or in secondary circuits of cooling distribution systems.
* Stand alone circulators are commonly available on the market.
** circulators integrated in products are component of a device, such as boilers, heat
pumps, etc..

This Regulation shall not apply to:


a) drinking water circulators
b) circulators integrated in products and placed on the market not later than 1 January
2020 as replacement for identical circulators integrated in products and placed on the
market no later than 1 August 2015. The replacement product or its packaging must
clearly indicate the product(s) for which it is intended.

a
i
Energ e
EEI < 0,23
EEI < 0,27

This Regulation shall apply in accordance with the following timetable:


1. from 1 January 2013, glandless standalone circulators shall meet the efficiency level
(EEI) less than 0.27, with the exception of those specifically designed for primary
circuits of thermal solar systems and of heat pumps;
2. from 1 August 2015, glandless standalone circulators and glandless circulators
integrated in products shall meet the efficiency level (EEI) less than 0.23.

0,27 < EEI < 0,4


0,4 < EEI < 0,6
0,6 < EEI < 0,8
0,8 < EEI < 1,0
1,0 < EEI < 1,2
1,2 < EEI < 1,4
EEI < 1,4

y
2015
2013

A
B
C
D
E
F
G

55
677

Technical appendix
EFFICIENCY OF WATER PUMPS

Directive of the European Parliament COMMISSION REGULATION (EC) No 547/2012


With the Eco-design Directive of Energy Using Products (ErP Directive Energy-related
Products) the European Union wants to improve the design of equipment that consume
significant energy (e.g. televisions, refrigerators, washing machines, boilers, pumps, motors
etc.) to improve eco-design providing environmental sustainability, reducing negative
environmental impact as the consequence of production, use and disposal of products.
The objective of the Directive is to force manufacturers and importers to produce and
distribute products with high energy efficiency, and reduced carbon output.
The criteria for eco-design will be an integral part of the declaration of conformity (CE), which
is a necessary requirement/mark for products being sold in the EU.

This Regulation shall apply to:


The Regulation 547/2012/EC defines the eco-design requirements for marketing centrifugal water pumps in the European market, even
if they are integrated in other products (OEM). The Regulation provides the introduction and the calculation of a minimum efficiency
index (MEI).
The pumps involved in the Regulation are:
- End suction own bearing water pumps (ESOB) designed for pressures up to 16 bar, a maximum shaft power of 150 kW, a maximum
head of 90 m at nominal speed of 1450 rpm and a maximum head of 140 m at nominal speed of 2900 rpm;
- End suction close coupled water pumps (ESCC) designed for pressures up to 16 bar, a maximum shaft power of 150 kW, a maximum
head of 90 m at nominal speed of 1450 rpm and a maximum head of 140 m at nominal speed of 2900 rpm;
- End suction close coupled in-line water pumps (ESCCi) designed for pressures up to 16 bar, a maximum shaft power of 150 kW, a
maximum head of 90 m at nominal speed of 1450 rpm and a maximum head of 140 m at nominal speed of 2900 rpm;
- Vertical multistage water pumps (MS-V) designed for pressures up to 25 bar, with a nominal speed of 2900 rpm and a maximum flow
of 100 m3/h (27,78103 m3/s);
- Submersible multistage water pumps (MSS) with a nominal outer diameter of 4 (10,16 cm) or 6 (15,24 cm) designed to operate in
a borehole at nominal speed of 2 900 rpm, at operating temperatures within a range of 0 C and 90 C;

This Regulation shall not apply to:


a) Water pumps designed specifically for pumping clean water at temperatures below 10 C or above 120 C.
b) Water pumps designed only for fire-fighting applications.
c) Displacement water pumps.
d) Self-priming water pumps.

This regulation shall apply in accordance with the following timetable:


1) From 1 January 2013, water pumps shall have: at the best efficiency point (BEP), at part load (PL), at over load (OL) a minimum
efficiency index MEI 0,10.
2) From 1 January 2015, water pumps shall have: at the best efficiency point (BEP), at part load (PL), at over load (OL) a minimum
efficiency index MEI 0,40.
The information on benchmark efficiency is available on the web site www.europump.org/efficiencycharts
The MEI value of Calpeda pumps is available on the web site www.calpeda.com

Regulation (EU) No 547/2012


- The benchmark for most efficient water pumps is MEI 0,70.
- The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt
the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter.
- The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable
speed drive that matches the pump duty to the system.

678

Catalogue

50Hz

February 2015 C201-14/3


Changes reserved

Вам также может понравиться