Limiting Conditions :
2
Installation :
The valve should be installed in a horizontal pipeline
with direction of flow as indicated by the arrow on the
valve body. Full instructions are supplied in the
Installation and Maintenance Instructions.
15
69
181
131
160
237
20
69
181
131
160
237
25
79
203
145
180
247
D1
40
96
251
173
158
359
50
96
251
173
180
359
General Tolerance upto 25 mm 4
Above 25 mm 7
SPX - 1
Material :
Sr.
No.
Part
Material
Standard
Sr. Part
No.
Material
Standard
1
2
Adjustment Bolts
Adjustment Lock Nut
Carbon Steel
Stainless Steel
Type 304
Stainless Steel
Type 304
Cast - Iron
C-20
Stainless Steel
Type 302
C - 20
Carbon Steel
IS 1367 Gr. 14
-
16
Stainless Steel
Type 302
Stainless Steel
Type 420
Stainless Steel
Type 420
Stainless Steel
Type 304
Cast Iron
Carbon Steel
IS 4454
Part IV Gr 1
ASTM A-276
BS 1452 Gr 14
HT IS 1367
Cast Iron
Carbon Steel
BS 1452 Gr 14
IS 1367
Stainless Steel
Type 304
Stainless Steel
Stainless Steel
Type 304
Stainless Steel
Carbon Steel
Carbon Steel
Stainless Steel
Type 316
ASTM A-240
Washer
4
5
6
Spring Housing
Top Spring Pad
Pressure Adjustment
Spring
Bottom Spring Pad
Spring Housing
Securing Stud & Nuts
Pilot Diaphragms
10
11
7
8
12
13
14
Screen
15
Body Gasket
Stainless Steel
Type 304
Cast Iron
Stainless Steel
Type 304
Stainless Steel
Stainless Steel
Type 410
Stainless Steel
Type 304
CAF
17
Main Valve
Return Spring
Main Valve
18
19
20
21
24
25
26
27
28
29
30
Pipe Assembly
Plug BSP
Pressure Pipe Union
Lock-Nut
ASTM A-240
IS 210 FG 220
IS 4454
Part IV Gr 1
HT IS 1367
ASTM A-240
BS 1452 Gr 14
ASTM A-276
ASTM A 240
ASTM A 276
ASTM A-240
22
23
IS 2712
SPX - 2
ASTM A -276
ASTM A-279
ASTM A-276
ASTM A-106
ASTM A-105
ASTM A-105
-
Saturated Steam :
Required a valve to pass 500 kg/h reducing from 6 bar
to 4 bar. Find a point at which curved 6 bar upstream
pressure line crosses horizontal 4 bar downstream
pressure line. A perpendicular dropped from this point
gives the capacities of all sizes under these
conditions. A 40 NB valve is the smallest size which
will carry the required load.
Superheated Steam :
Because of the higher specific volume of superheated
steam a correction factor must be applied to the figure
0
obtained from this chart. For 55 C. of superheat the
0
factor is 0.95 and for 110 C. of superheat it is 0.9.
Using the example given for saturated steam, the 40
NB valve would pass 1150 x 0.95 = 1092 kg/ h if the
0
steam had 55 C. of superheat. It is still big enough to
pass the required load of 500 kg/h.
Special versions of these valve having soft main
valves for use on compressed air are available
subject to special quotation.