MACLEAN

POWER
SYSTEMS

Insulator Products

Rev: A2 Date: 04/2004

Table of Contents
Products

Section

Page Numbers

Distribution Deadends

DDE

DDE-1 to DDE-2

Distribution Line Posts

DLP

DLP-1

to

DLP-5

Distribution Station Posts

SP100

SP100-1

to

SP100-2

General Information
Application Guide
Distribution Insulators

Transmission Insulators
Suspension Insulators

SI

SI-1

to

SI-5

Line Post Insulators

LP

LP-1

to

LP-9

Station Post Insulators

SP200

SP200-1

to

SP200-3

Braced Post Insulators

BP

Hardware Assemblies

HA

Insulator Index - Page: 1 of 3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Insulator Products

Rev: A2 Date: 04/2004

Insulator Index
Insulator Type

Voltages

Distribution Deadends

Section

Page No.

DDE

DDE Information
DS-M Series Insulators
DS-G FiberLink

15kV 28kV
15kV 35kV

Distribution Line Posts

DDE-1
DDE-2

DLP

DLP Information
1.5 Line Posts
LPC Series Insulators
LPCV Series Insulators

15kV 35kV
15kV 35kV

DLP-1
DLP-2

44kV 88kV
44kV 88kV
15kV - 69kV

DLP-3
DLP-4
DLP-5

1.75 Line Posts


OLPK Series Insulators
OLPV Series Insulators
Tie-Top / F-Neck Insulators

Distribution Station Posts

SP100

Station Post Information


Standard Strength Station Posts (1.75 Solid Core)
High Strength Station Posts (2.5 Solid Core)

7.5kV 69kV
7.5kV 69kV

Suspension Insulators

SP100-1
SP100-2

SI

Suspension Information
S1 Series Insulators 25k SML (16mm Rod)

69kV 500kV

SI-1

S5 Series Insulators 30k SML (18mm Rod)

69kV 500kV

SI-2

S6 Series Insulators 36k SML (18mm Rod)

69kV 500kV

SI-3

S2 Series Insulators 50k SML (24mm Rod)

69kV 500kV

SI-4

S4 Series Insulators 80k SML (32mm Rod)

230kV 500kV

SI-5

Line Post Insulators

LP

H1 Series Line Posts 2.0 Rod


H1C1 Drop Tongue / Fixed Base
H1C2 - Trunnion / Fixed Base
H191 - Drop Tongue / Bendable Base

69kV 161kV
69kV 161kV
69kV 161kV

LP-1
LP-2
LP-3

H2 Series Line Posts 2.5 Rod


NPKG - Trunnion / Fixed Base
NBKG - Trunnion / Bendable Base
NBSG - Drop Tongue / Bendable Base
H291 Drop Tongue / Bendable Base

69kV 230kV
69kV 230kV
69kV 230kV
230kV 345kV

LP-4
LP-5
LP-6
LP-7

Insulator Index - Page: 2 of 3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Insulator Products

Rev: A2 Date: 04/2004

Insulator Type

Voltages

Line Post Insulators (continued)

Section

Page No.

LP

H3 Series Line Posts 3.0 Rod


H391 Drop Tongue / Bendable Base

115kV 345kV

LP-8

H3A Series Line Posts 3.5 Rod


NBSG40XV Drop Tongue / Bendable Base

115kV 161kV

LP-9

Station Post Insulators

SP200

Station Post Information


2.5 Station Posts NAA100XH Series

69kV 315kV

SP200-1

3.5 Station Posts NAA200XV Series

69kV 500kV

SP200-2 -3

Braced Post Insulators

BP

Braced Post Information


Standard Strength 2.5 Braced Posts
B291 Series Bendable Base Design
B261 Series Swivel Base Design
High Strength 3.0 Braced Posts
B391 Series Bendable Base Design
B361 Series Swivel Base Design

Hardware Assemblies

HA

Insulator Index - Page: 3 of 3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER

Distribution Deadend Information

SYSTEMS
Rev: A1, Date: 02/2004

This Page of the


MacLean Power Systems
On-Line Catalog is currently
Under Construction

We expect this page to be active in the near future.

Please check again soon.

DDE Information Page DDE-I-1 of DDE-I-1


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Distribution Deadend Insulators

Rev: A2, Date: 04/2004

DS-M Series
15kV 28kV

Typical
Line
Voltage Catalog No.
kV

Electrical Flashover (kV)

Section
Length

Dry Arc

Leakage

in [mm]

in [mm]

in [mm]

Dry

Wet

Pos

Neg

lbs.

kg.

60 Hz

Weight

CIFO

15

DS-15M

13.0
[330]

7.6
[192]

15.8
[401]

90

65

140

145

2.6

1.18

28

DS-28M

17.0
[430]

11.6
[294]

24.7
[628]

130

100

190

220

2.9

1.32

Notes:

SML = 15,000 lbs [66.7 kN]


RTL = 7,500 lbs [33.4 kN]
All ratings meet or exceed the requirements of ANSI C29.13 (2000) and LWIWG-01 (96)
Corrosion Resistant Fiberglass Core / Silicone Housing
RUS Accepted

Distribution Deadend Insulators Page DDE-1 of DDE-2


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Distribution Deadend Insulators

Rev: A2, Date: 04/2004

FIBERLINK
15kV 35kV

Metal Eyelets
G Galvanized
S Stainless Steal (300 Series)

Typical
Line
Voltage Catalog No.
kV

15
28
35

DS-15G
DS-15S
DS-28G
DS-28S
DS-35G
DS-35S

Electrical Flashover (kV)

Section
Length

Leakage

in [mm]

in [mm]

Dry

Wet

Pos

Neg

lbs.

kg.

CTN

Pallet

12.50
[318]

15.0
[381]

133

112

202

225

1.2

.54

18

540

17.78
[451]

26.0
[660]

177

157

286

357

1.6

.73

18

486

22.55
[572]

34.8
[884]

222

199

325

401

2.0

.91

18

342

60 Hz

CIFO

Weight

Quantity

Notes:
SML = 15,000 lbs [66.7 kN]
RTL = 7,500 lbs [33.4 kN]

Distribution Deadend Insulators Page DDE-2 of DDE-2


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER

Distribution Line Post Information

SYSTEMS
Rev: A1, Date: 02/2004

This Page of the


MacLean Power Systems
On-Line Catalog is currently
Under Construction

We expect this page to be active in the near future.

Please check again soon.

DLP Information Page DLP-I-1 of DLP-I-1


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Distribution Line Post Insulators

Rev: A2, Date: 04/2004

LPC Series Horizontal Trunnion Insulators

1.5 [38mm] Dia. Rod

LPC Insulators - Stud Mounting Type


Electrical Flashover (kV)
60 Hz
CIFO

Weight

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

7.2
[183]

11.3
[287]

86

66

146

193

6.2
[2.8]

162

14.9
[378]

11.2
[284]

18.8
[478]

122

103

208

271

7.1
[3.2]

108

16.9
[429]

13.2
[335]

22.4
[569]

141

122

239

309

7.6
[3.4]

108

Line
Voltage

MDCL

Catalog No.

Section
Length

Dry Arc

Leakage

kV

lbs [kN]

Product ID No.

in [mm]

in [mm]

15

1235
[5.5]

NPKN10XB003S0

10.9
[277]

28

1235
[5.5]

NPKN10XB005S0

35

1235
[5.5]

NPKN10XB006S0

[ LPC-15-SIL ]

[ LPC-28-SIL ]

[ LPC-35-SIL ]

Standard
Box Pallet
Qty
Qty

LPC Insulators with Gain Base: for pole mounted line posts
Line
Voltage

MDCL

Catalog No.

Section
Length

Dry Arc Leakage Weight

kV

lbs [kN]

Product ID No.

in [mm]

in [mm]

in [mm]

lbs [kg]

15

1235
[5.5]

NPKG10XB003S0

12.4
[315]

7.2
[183]

11.3
[287]

13.2
[6.0]

42

28

1235
[5.5]

NPKG10XB005S0

16.4
[417]

11.2
[284]

18.8
[478]

14.1
[6.4]

42

35

1235
[5.5]

NPKG10XB006S0

18.4
[467]

13.2
[335]

22.4
[569]

14.6
[6.6]

42

Notes:

[ LPC-15-SIL-GB-12 ]

[ LPC-28-SIL-GB-12 ]

[ LPC-35-SIL-GB-12 ]

Standard
Crate Qty

MDCL = Max. Design Cantilever Load


To order LPC Series Insulators, contact your local MPS Sales Representative.
LPC Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-1 of DLP-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Distribution Line Post Insulators

Rev: A2, Date: 04/2004

LPCV Series Vertical Trunnion Insulators

1.5 [38mm] Dia. Rod

Vertical Mounting Base: VB-08

Stud Mounted

LPCV Insulators - Stud Mounting Type


Line
Voltage

MDCL

Catalog No.

Section
Length

Dry Arc Leakage

Electrical Flashover (kV)


60 Hz
CIFO

Weight

kV

lbs [kN]

Product ID No.

in [mm]

in [mm]

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

15

1235
[5.5]

NPVN10XB003S0

10.9
[277]

7.2
[183]

11.3
[287]

86

66

146

193

6.1
[2.8]

216

28

1235
[5.5]

NPVN10XB005S0

14.9
[378]

11.2
[284]

18.8
[478]

122

103

208

271

7.1
[3.2]

162

35

1235
[5.5]

NPVN10XB006S0

16.9
[429]

13.2
[335]

22.4
[569]

141

122

239

309

7.7
[3.5]

162

[ LPCV-15-SIL ]

[ LPCV-28-SIL ]

[ LPCV-35-SIL ]

Standard
Box Pallet
Qty
Qty

LPCV Insulators with Vertical Gain Base: for pole mounted line posts
Line
Voltage

MDCL

Catalog No.

Section
Length

kV

lbs [kN]

Product ID No.

in [mm]

in [mm]

in [mm]

lbs [kg]

15

1235
[5.5]

NPVG10XB003S0

25.2
[640]

7.2
[183]

11.3
[287]

14.3
[6.5]

40

28

1235
[5.5]

NPVG10XB005S0

29.2
[742]

11.2
[284]

18.8
[478]

15.3
[6.9]

40

35

1235
[5.5]

NPVG10XB006S0

31.2
[792]

13.2
[335]

22.4
[569]

15.8
[7.2]

40

Notes:

[ LPCV-15-SIL-VB-08 ]

[ LPCV-28-SIL-VB-08 ]

[ LPCV-35-SIL-VB-08 ]

Dry Arc Leakage Weight

Standard
Crate Qty

MDCL = Max. Design Cantilever Load


To order LPCV Series Insulators, contact your local MPS Sales Representative.
LPCV Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-2 of DLP-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Distribution Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

OLPK Series Horizontal Trunnion Insulators

1.75 [45mm] Dia. Rod

Taps
OLPK-13 = -10
OLPK-17 = 7/8-9
MLPK-21 = 7/8-9
MLPK-25 = 7/8-9

Stud Mounting Type


Electrical Flashover (kV)
60 Hz
CIFO

Weight

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

42.3
[1074]

188

168

318

403

11.3
[5.1]

72

22.3
[566]

54.0
[1372]

224

203

381

472

13.4
[6.1]

72

26.0
[660]

23.0
[584]

59.4
[1509]

231

210

392

484

13.7
[6.2]

72

30.0
[762]

27.0
[686]

71.1
[1806]

268

245

455

550

15.6
[7.1]

72

Catalog No.

Section
Length

Dry Arc

Leakage

lbs [kN]

Product ID No.

in [mm]

in [mm]

46

1250
[5.6]

NPKN20XG13S0

22.0
[559]

18.3
[465]

69

1200
[5.3]

NPKN20XG17S0

26.0
[660]

69

1200
[5.3]

NPKN20XGM21S0

88

921
[4.1]

NPKN20XGM25S0

Line
Voltage

MDCL

kV

[ OLPK-13-SIL ]

[ OLPK-17-SIL ]

[ MLPK-21-SIL ]

[ MLPK-25-SIL ]

Standard
Box Pallet
Qty
Qty

Insulators with Gain Base: for pole mounted line posts


Line
Voltage

MDCL

Catalog No.

Section
Length

Dry Arc

kV

lbs [kN]

Product ID No.

in [mm]

in [mm]

in [mm]

lbs [kg]

46

1250
[5.6]

NPKG20XG13S0

23.4
[594]

18.3
[465]

42.3
[1074]

18.8
[8.5]

42

69

1200
[5.3]

NPKG20XG17S0

27.4
[696]

22.3
[566]

54.0
[1372]

20.3
[9.2]

42

69

1200
[5.3]

NPKG20XGM21S0

27.4
[696]

23.0
[584]

59.4
[1509]

20.7
[9.4]

42

88

921
[4.1]

NPKG20XGM25S0

Notes:

[ OLPK-13-SIL-GB-12 ]

[ OLPK-17-SIL-GB-12 ]

[ MLPK-21-SIL-GB-12 ]

Leakage Weight

Standard
Crate Qty

31.4
27.0
71.1
22.3
42
[798]
[686]
[1806]
[10.1]
MDCL = Max. Design Cantilever Load
To change from Trunnion to Tongue end fitting, change the K to a T [EX = OLPT-13]
To order OLPK Series Insulators, contact your local MPS Sales Representative.
OLPK Series Insulators for use in North American Market Only.
[ MLPK-25-SIL-GB-12 ]

Distribution Line Post Insulators Page DLP-3 of DLP-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Distribution Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

OLPV Series Vertical Trunnion Insulators

1.75 [45mm] Dia. Rod

Taps
OLPV-13 = -10
OLPV-17 = 7/8-9
MLPV-21 = 7/8-9
MLPV-25 = 7/8-9

Vertical Mounting Base: VB-08

Stud Mounted

Stud Mounting Type


Electrical Flashover (kV)
60 Hz
CIFO

Weight

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

42.3
[1074]

188

168

318

403

11.3
[5.1]

108

22.3
[566]

54.0
[1372]

224

203

381

472

13.4
[6.1]

72

26.0
[660]

23.0
[584]

59.4
[1509]

231

210

392

484

14.2
[6.4]

72

30.0
[762]

27.0
[686]

71.1
[1806]

267

245

455

550

15.6
[7.1]

72

Catalog No.

Section
Length

Dry Arc

Leakage

lbs [kN]

Product ID No.

in [mm]

in [mm]

46

1250
[5.6]

NPVN20XG13S0

22.0
[559]

18.3
[465]

69

1200
[5.3]

NPVN20XG17S0

26.0
[660]

69

1200
[5.3]

NPVN20XGM21S0

88

921
[4.1]

NPVN20XGM25S0

Line
Voltage

MDCL

kV

[ OLPV-13-SIL ]

[ OLPV-17-SIL ]

[ MLPV-21-SIL ]

[ MLPV-25-SIL ]

Standard
Box Pallet
Qty
Qty

Insulators with Vertical Gain Base: for pole mounted line posts
Line
Voltage

MDCL

Catalog No.

Section
Length

Dry Arc Leakage Weight

kV

lbs [kN]

Product ID No.

in [mm]

in [mm]

in [mm]

lbs [kg]

46

1250
[5.6]

NPVG20XG13S0

25.2
[640]

18.3
[465]

42.3
[1074]

19.6
[8.9]

40

69

1200
[5.3]

NPVG20XG17S0

29.2
[742]

22.3
[566]

54.0
[1372]

21.1
[9.6]

40

69

1200
[5.3]

NPVG20XGM21S0

29.2
[742]

23.0
[584]

59.4
[1509]

22.3
[10.1]

40

88

921
[4.1]

NPVG20XGM25S0

31.2
[792]

27.0
[686]

71.1
[1806]

23.7
[10.8]

40

Notes:

[ OLPV-13-SIL-VB-08 ]

[ OLPV-17-SIL-VB-08 ]

[ MLPV-21-SIL-VB-08 ]

[ MLPV-25-SIL-VB-08 ]

Standard
Crate Qty

MDCL = Max. Design Cantilever Load


To order OLPV Series Insulators, contact your local MPS Sales Representative.
OLPV Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-4 of DLP-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Distribution Line Post Insulators

Rev: A2, Date: 04/2004

Tie-Top Insulator / F-Neck Design

1.75 [45mm] Dia. Rod

Conductor, if bare, to be protected by a pad


from direct contact to the metallic neck.

Electrical Flashover (kV)


60 Hz
CIFO

Weight

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

11.0
[279]

25.0
[635]

121

101

204

267

11.0
[5.0]

162

16.1
[409]

13.0
[330]

30.7
[780]

140

120

236

306

12.3
[5.6]

162

NPNN20XG13S0

18.3
[465]

15.2
[386]

36.5
[927]

160

140

270

347

13.1
[5.9]

108

1250
[5.6]

NPNN20XG15S0

20.2
[513]

17.0
[432]

42.4
[1077]

176

156

298

380

13.8
[6.3]

108

1250
[5.6]

NPNN20XG17S0

22.4
[569]

19.0
[483]

48.2
[1224]

195

174

330

415

14.5
[6.6]

72

Line
Voltage

MDCL

Catalog No.

Section
Length

Dry Arc

Leakage

kV

lbs [kN]

Product ID No.

in [mm]

in [mm]

25

1250
[5.6]

NPNN20XG09S0

14.3
[363]

25
35

1250
[5.6]

NPNN20XG11S0

35

1250
[5.6]

46
69
Notes:

Standard
Box Pallet
Qty
Qty

MDCL = Max. Design Cantilever Load


For pole mounted line posts, add VB-08 to catalog number, [EX = NPNN20XG09S0-VB-08]
To order F-Neck Series Insulators, contact your local MPS Sales Representative.
F-Neck Series Insulators for use in North American Market Only.

Distribution Line Post Insulators Page DLP-5 of DLP-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Distribution Station Posts - SP100

POWER
SYSTEMS
Rev: A2, Date: 04/2004

NPP20XG Series Station Posts


For Systems from

7.5kV to 69kV
B.I.L.: 95kV --- 350kV

P End Fittings = 3 Bolt Circle


Class 20 = 1.75 Solid Rod
HTV Silicone Rubber housing
Meets or Exceeds the ANSI C29.9 Electrical requirements

Tensile Strength = 16,000 lbs


Torsional Strength = 12,000 in-lbs
Compression Strength = 10,000 lbs
[NPP20XG27S = 7,500 lbs]

BIL Rating

Low Freq.
withstand

Test Voltage
to ground

CIFO +

SCL

MDCL

Deflection

inch

lbs.

kV

kV

kV

kV

lbs

lbs

inch

@ TR MWL

Weight

inch

@ 1 MHz

Leakage

inch

Max. RIV

Dry Arc

kV

Mechanical

Height

Catalog No.

Porcelain TR

Typical Line
Voltage

Electrical Characteristics

7.5

NPP20XG05S

202

7.5

6.1

12.7

95

30

50

105

2000

800

0.1

15

NPP20XG07S

205

10.0

8.9

20.5

110

45

50

10

125

2000

800

0.1

23

NPP20XG11S

208

14.0

12.9

32.2

150

60

100

15

170

2000

800

0.2

34.5 NPP20XG15S 210

18.0

16.9

43.9

10

200

80

100

22

225

2000

800

0.4

46

NPP20XG19S

214

22.0

20.9

55.6

12

250

100

200

30

280

2000

800

0.7

69

NPP20XG27S

216

30.0

28.1

77.0

17

350

145

200

44

390

1500

600

1.5

Notes:

SCL = Specified Cantilever Load


MDCL = Max. Design Cantilever Load
To order Distribution Station Posts, contact your local MPS Sales Representative.
Station Posts for use in North American Market Only.

Distribution Station Post Page: SP100-1 of SP100-2


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Distribution Station Posts - SP100

POWER
SYSTEMS
Rev: A2, Date: 04/2004

NAA100XH Series Station Posts


For Systems from

7.5kV to 69kV
B.I.L.: 95kV --- 350kV
HIGH STRENGTH
A End Fittings = 5 Bolt Circle
Class 100 = 2.5 Solid Rod
HTV Silicone Rubber housing
Meets or Exceeds the ANSI C29.9 Electrical requirements

Tensile Strength = 16,000 lbs


Torsional Strength = 12,000 in-lbs
Compression Strength = 25,000 lbs

BIL Rating

Low Freq.
withstand

Test Voltage
to ground

CIFO +

SCL

MDCL

Deflection

inch

lbs.

kV

kV

kV

kV

lbs

lbs

inch

@ TR MWL

Weight

inch

@ 1 MHz

Leakage

inch

Max. RIV

Dry Arc

Mechanical

Height

Catalog No.

Porcelain TR

Typical Line
Voltage

Electrical Characteristics

kV

23

NAA100XH06S

227

15.0

11.7

27.0

26

150

60

100

15

170

8000 6000

0.2

34.5 NAA100XH09S

231

20.0

16.2

40.8

30

200

80

100

22

225

6500 4200

0.3

46

NAA100XH12S

267

24.0

20.8

53.6

34

250

100

200

30

280

5500 3500

0.6

69

NAA100XH16S

278

30.0

26.8

72.0

38

350

145

200

44

390

4400 2770

0.7

Notes:

SCL = Specified Cantilever Load


MDCL = Max. Design Cantilever Load
To order Distribution Station Posts, contact your local MPS Sales Representative.
Station Posts for use in North American Market Only.

Distribution Station Post Page: SP100-2 of SP100-2


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Suspension Information

Rev: A2, Date: 04/2004

The MPS Complete Solution

CR E-Glass Core MPS uses Boron Free Corrosion Resistant E-Glass on all its insulators for its
High Electrical Integrity & High Resistance to acid corrosion. The Boron Free formulation of the
fiberglass core makes it resistant to Nitric Acid attacks. There has never been a brittle facture
failure of a CR E-glass insulator in over 30 years of use.

Silicone Rubber MPS uses a Silicone formulation that has been utilized since 1984. The Si-O
Molecular Bonds (Inorganic Backbone of Silicone) are very stable and have Bond Strengths
higher than Sunlight, making the silicone resistant to UV degradation. In addition to providing
protection against ultraviolet radiation, electrical aging, and corona effect, silicone exhibits
hydrophobic properties; which provide excellent recovery characteristics to control leakage
currents in highly polluted or seacoast environments.
The MPS silicone rubber formulation has consistently outperformed other silicone formulations
in its hydrophobicity, its hydrophobicity recovery rate, and enhanced electrical properties in
contaminated environments

P-S-T End Fitting Seal The P-S-T sealing system is a triple seal design with built-in redundancies.
Primary seal rubber sheath compressed into chamfer of end fitting. Secondary seal RTV
silicone applied to core / sheath / end fitting interface. Tertiary seal Final external RTV seal
applied to sheath / end fitting interface. The P-S-T system has clearly shown its superiority to
withstand moisture penetration.

Stacked Shed The MPS Stacked Shed configuration offers inherent protection against material aging in
critical areas of the sheath and resists the resultant material erosion when installed in highly
contaminated environments (resistance to Water Droplet Corona). In addition, stacked shed
profiles enhance the ability of the insulator to resist mechanical damage in these most critical
areas during transportation and installation.

Suspension Insulator Information Page SI-I-1 of SI-I-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Suspension Information

POWER
SYSTEMS
Rev: A2, Date: 04/2004

INSULATOR
TYPE
[ Specified
Mechanical Load ]

S1 25k SML
S5 30k SML
S6 36k SML
S2 50k SML
S4 80k SML

Catalog Number Definition


4
8 0 9 7
V
A
TOWER

01

LINE

END FITTING
TYPE

SECTION LENGTH
(Inches)

4 Y-Clevis
5 Tongue
6 Clevis
7 Socket
8 Ball
9 Eye

S 2 4 8 0 9 7 V A 0 1

MPS
INTERNAL
USE

CORONA
RINGS

ABCDE-

MPS Catalog
Number Example

Tower Line
None
8
None
12
None
17
8
8
12
12

Tower Line
17
17
8
12
12
17
8
17
None None

FGHVX-

To order a 97 50k SML


Y-Clevis / Ball Insulator with an
8 Corona Ring, the Catalog
number would be

MPS Identification
8" Corona Ring on the Line End
Variable Leakage
97" Insulator Section Length

S248097VA01

Ball EF on Line End


Y-Clevis EF on Tower End
50k SML Insulator

SUSPENSION INSULATORS
AVAILABLE END FITTINGS

End Fitting
Type

Y-Clevis
Insulators

S1
S5
S6

25klb

ANSI

IEC

*Yes

120kN

Tongue
ANSI

IEC

52-6
*Yes

Clevis
ANSI

IEC

52-6
16-C

IEC

52-5

Ball
ANSI

Eye

IEC

52-5
16

ANSI

*Yes

*Yes

52-6

52-6

52-5

52-5

*Yes

36klb

*Yes

52-6

52-6

52-8 +

52-8 +

*Yes

160kN

*Yes

16N

19-L

50klb

20
52-5

*Yes

52-12

52-10
22N

20

*Yes

52-5

52-11

19-C/22-L

IEC

*Yes
16

30klb

210kN

S4

ANSI

16-C

30klb

S2

Socket

52-11
20/24

*Yes
20/24

80klb

*Yes
*Yes

300kN

22-L

24+

24+

*Yes

+ = Consult MPS for design availability

* = No ANSI or IEC classification available.


Suspension Insulator Information Page SI-I-2 of SI-I-3
USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Suspension Information

POWER
SYSTEMS
Rev: A2, Date: 04/2004

Corona Rings for Suspension Insulators


High Voltages can result in unwanted noise (RIV)
and corona. To minimize the effects of corona,
coronar rings are applied to one or both ends of
the insulator (attached onto the end fittings).
Typically, for system voltages 230kV and above a
corona ring or combination of rings is necessary.
However, some applications may require rings at
lower system voltages. Refer to the Corona Ring
section of the Application Guide for detailed
information.
MPS corona rings are designed around the needs of the end user. It is easy to
install, unidirectional (not able to install in the wrong direction), and can be installed or
removed with hot stick tools. By making the ring a one piece design, we have
eliminated the problem of missing or lost parts. This was made possible by designing a
unique clamping mechanism that uses one captive bolt to secure the rinf to the
insulator. Additionally, the clamping section was designed such that the ring can only
be installed in one direction, which eliminates the problem of misapplied rings. As a
final step, the ring was designed with a split (opening) to allow installation with hot stick
tools.

Corona Ring Application Table


138kV

161kV

230kV

345kV

400kV

500kV

Line End

None

None

8"

12"

12"

17"

Tower End

None

None

None

None

8"

8"

Three Ring Diameters are available for use on all suspension insulator styles:

8 Ring, 12 Ring, and 17 Ring


For Insulators 230kV and above, MPS recommends use of Corona Rings. The
Application Table above depicts typical corona ring useage on MPS suspension
Insulators. For corona ring useage on special applications, environments, and
elevations; please contact MPS.

Suspension Insulator Information Page SI-I-3 of SI-I-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Suspension Insulators

POWER
SYSTEMS
Rev: A1, Date: 02/2004

S1 Series Insulators
Insulator Strength Ratings
SML

S1

RTL

25 klb

12.5 klb

120 kN

60 kN

16mm Rod
Line
Voltage
kV

69
115
115
138
161
161
230
230
230
345
500
Notes:

"S1" Type
Catalog No.
S148040VX33
S148040VX06
S148040VX21
S148048VX24
S148048VX02
S148048VX11
S148052VX39
S148052VX36
S148052VX37
S148060VX35
S148060VX04
S148060VX36
S148064VX23
S148064VX29
S148064VX26
S148068VX14
S148068VX15
S148068VX17
S148089VX03
S148089VX04
S148089VX06
S148096VX03
S148096VX04
S148096VX06
S148104VX07
S148104VX08
S148104VX09
S148120VX01
S148120VX02
S148120VX02
S148165VX03
S148165VX04
S148165VX06

Section
Length

Dry Arc

in [mm]

in [mm]

in

40.0
[1016]

29.9
[759]

48.0
[1219]

37.9
[963]

52.0
[1321]

42.9
[1090]

60.0
[1524]

49.9
[1267]

64.0
[1626]

53.9
[1369]

68.0
[1727]

57.9
[1471]

89.0
[2261]

78.9
[2004]

96.0
[2438]

85.9
[2182]

104.0
[2642]

93.9
[2385]

120.0
[3048]

109.9
[2791]

165.0
[4191]

154.9
[3934]

47.7
70.9
90.3
78.9
121.5
140.9
79.1
117.8
144.9
94.8
141.2
172.2
106.5
168.5
202.0
106.7
164.7
206.0
150.9
236.0
290.2
150.2
239.2
293.3
150.4
239.4
293.6
228.3
356.0
433.4
331.4
517.1
613.9

Leakage
[mm]

Electrical Flashover (kV)


60 Hz
CIFO
Dry

[1212]
[1801] 299
[2294]
[2004]
[3086] 375
[3579]
[2009]
[2992] 413
[3680]
[2408]
[3586] 490
[4374]
[2705]
[4280] 528
[5131]
[2710]
[4183] 566
[5232]
[3833]
[5994] 766
[7371]
[3815]
[6076] 832
[7450]
[3820]
[6081] 909
[7457]
[5799]
[9042] 1039
[11008]
[8418]
[13134] 1368
[15593]

Wet

Pos

Neg

270

519

556

338

648

690

372

712

756

437

837

886

469

899

949

500

960

1013

657

1276

1335

707

1379

1440

774

1496

1559

893

1729

1795

1143

2374

2444

Weight
lbs

6.5
8.3
9.8
8.6
11.9
13.9
8.4
11.4
14.0
9.3
12.9
15.3
10.1
14.9
18.1
9.9
14.4
19.3
12.5
19.1
24.2
12.1
19.0
23.2
11.8
18.7
22.9
17.2
27.1
34.5
23.3
37.3
47.2

[kg]

[2.9]
[3.8]
[4.4]
[3.9]
[5.4]
[6.3]
[3.8]
[5.2]
[6.4]
[4.2]
[5.9]
[6.9]
[4.6]
[6.8]
[8.2]
[4.5]
[6.5]
[8.8]
[5.7]
[8.7]
[11.0]
[5.5]
[8.6]
[10.5]
[5.4]
[8.5]
[10.4]
[7.8]
[12.3]
[15.6]
[10.6]
[16.9]
[21.4]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.
For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-1 of SI-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Suspension Insulators

POWER
SYSTEMS
Rev: A1, Date: 02/2004

S5 Series Insulators
Insulator Strength Ratings
SML

S5

RTL

30 klb

15 klb

133 kN

66.5 kN

18mm Rod
Line
Voltage
kV

69
115
115
138
161
161
230
230
230
345
500
Notes:

"S5" Type
Catalog No.
S548040VX05
S548040VX07
S548040VX08
S548048VX03
S548048VX09
S548048VX10
S548052VX03
S548052VX05
S548052VX11
S548060VX03
S548060VX08
S548060VX10
S548064VX13
S548064VX14
S548064VX16
S548068VX10
S548068VX11
S548068VX12
S548089VX01
S548089VX02
S548089VX03
S548096VX03
S548096VX07
S548096VX09
S548104VX03
S548104VX06
S548104VX07
S548120VX03
S548120VX08
S548120VX10
S548165VX03
S548165VX04
S548165VX05

Section
Length

Dry Arc

in [mm]

in [mm]

in

40.0
[1016]

28.0
[711]

48.0
[1219]

36.0
[914]

52.0
[1321]

40.0
[1016]

60.0
[1524]

48.0
[1219]

64.0
[1626]

52.0
[1321]

68.0
[1727]

56.0
[1422]

89.0
[2261]

77.0
[1956]

96.0
[2438]

84.0
[2134]

104.0
[2642]

92.0
[2337]

120.0
[3048]

108.0
[2743]

165.0
[4191]

154.5
[3924]

45.6
72.7
88.2
76.9
119.4
155.3
77.0
119.6
146.9
92.7
143.0
173.6
108.3
166.4
205.7
108.5
166.5
209.7
152.7
237.8
296.3
151.9
237.1
293.9
152.2
237.3
295.4
230.1
357.8
434.2
333.2
518.9
625.3

Leakage
[mm]

[1158]
[1847]
[2240]
[1953]
[3033]
[3945]
[1956]
[3038]
[3731]
[2355]
[3632]
[4409]
[2751]
[4227]
[5225]
[2756]
[4229]
[5326]
[3879]
[6040]
[7526]
[3858]
[6022]
[7465]
[3866]
[6027]
[7503]
[5845]
[9088]
[11029]
[8463]
[13180]
[15883]

Electrical Flashover (kV)


60 Hz
CIFO
Dry

Wet

Pos

Neg

281

253

488

523

357

322

617

658

395

356

681

725

471

421

807

855

509

453

869

819

547

485

931

982

747

643

1247

1306

814

693

1351

1412

890

759

1468

1531

1025

879

1701

1767

1354

1134

2346

2417

Weight
lbs

7.0
9.0
10.1
9.0
12.1
16.5
8.9
12.0
14.9
9.8
13.4
16.8
10.8
15.0
19.2
10.7
14.9
19.4
13.3
19.4
25.5
13.1
19.1
25.1
12.9
18.9
23.1
18.0
27.1
35.4
24.1
37.3
49.1

[kg]

[3.2]
[4.1]
[4.6]
[4.1]
[5.5]
[7.5]
[4.0]
[5.4]
[6.8]
[4.4]
[6.1]
[7.6]
[4.9]
[6.8]
[8.7]
[4.9]
[6.8]
[8.8]
[6.0]
[8.8]
[11.6]
[5.9]
[8.7]
[11.4]
[5.9]
[8.6]
[10.5]
[8.2]
[12.3]
[16.1]
[10.9]
[16.9]
[22.3]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.
For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-2 of SI-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Suspension Insulators

POWER
SYSTEMS
Rev: A1, Date: 02/2004

S6 Series Insulators
Insulator Strength Ratings
SML

S6

RTL

36 klb

18 klb

160 kN

80 kN

18mm Rod
Line
Voltage
kV

69
115
115
138
161
161
230
230
230
345
500
Notes:

"S6" Type
Catalog No.
S648040VX01
S648040VX03
S648040VX03
S648048VX03
S648048VX04
S648048VX05
S648052VX03
S648052VX04
S648052VX05
S648060VX04
S648060VX05
S648060VX06
S648064VX05
S648064VX06
S648064VX07
S648068VX02
S648068VX03
S648068VX05
S648089VX05
S648089VX06
S648089VX08
S648096VX04
S648096VX05
S648096VX07
S648104VX01
S648104VX02
S648104VX03
S648120VX01
S648120VX02
S648120VX04
S648165VX01
S648165VX02
S648165VX03

Section
Length

Dry Arc

in [mm]

in [mm]

in

40.0
[1016]

28.4
[721]

48.0
[1219]

36.4
[925]

52.0
[1321]

40.4
[1026]

60.0
[1524]

48.4
[1229]

64.0
[1626]

52.4
[1331]

68.0
[1727]

56.4
[1433]

89.0
[2261]

77.4
[1966]

96.0
[2438]

84.4
[2144]

104.0
[2642]

92.4
[2347]

120.0
[3048]

108.4
[2753]

165.0
[4191]

153.4
[3896]

46.0
73.1
88.6
77.2
119.8
115.7
77.4
119.9
147.2
89.2
143.4
174.0
108.7
166.8
206.1
105.0
166.9
210.1
153.1
238.2
296.7
152.6
237.7
291.9
152.6
237.7
291.9
226.6
358.2
440.1
333.5
519.3
625.7

Leakage
[mm]

[1168]
[1857]
[2250]
[1961]
[3043]
[2939]
[1966]
[3045]
[3739]
[2266]
[3642]
[475]
[2761]
[4237]
[5235]
[2667]
[4239]
[5337]
[3889]
[6050]
[7536]
[3876]
[6038]
[7414]
[3876]
[6038]
[7414]
[5756]
[9098]
[11179]
[8471]
[13190]
[15893]

Electrical Flashover (kV)


60 Hz
CIFO
Dry

Wet

Pos

Neg

284

257

494

529

360

325

623

665

399

359

687

731

475

424

813

861

513

456

875

925

551

488

936

988

751

646

1253

1312

818

696

1356

1417

894

762

1474

1536

1028

881

1707

1772

1357

1136

2352

2422

Weight
lbs

6.9
8.8
9.9
8.9
11.9
16.3
8.8
11.8
14.7
9.4
13.2
16.6
10.7
14.8
19.0
10.3
14.7
19.2
13.1
19.2
25.4
12.9
18.9
24.9
12.7
18.7
22.6
17.5
26.9
35.7
23.9
37.1
49.0

[kg]

[3.1]
[4.0]
[4.5]
[4.0]
[5.4]
[7.4]
[4.0]
[5.4]
[6.7]
[4.3]
[6.0]
[7.5]
[4.9]
[6.7]
[8.6]
[4.7]
[6.7]
[8.7]
[5.9]
[8.7]
[11.5]
[5.9]
[8.6]
[11.3]
[5.8]
[8.5]
[10.3]
[7.9]
[12.2]
[16.2]
[10.8]
[16.8]
[22.2]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.
For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-3 of SI-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Suspension Insulators

POWER
SYSTEMS
Rev: A1, Date: 02/2004

S2 Series Insulators
Insulator Strength Ratings
SML

S2

RTL

50 klb

25 klb

210 kN

105 kN

24mm Rod
Line
Voltage

"S2" Type
Catalog No.

kV

S248056VX07
S248056VX08
S248056VX09
S248062VX13
S248063VX14
S248063VX16
S248068VX07
S248068VX08
S248068VX09
S248080VX10
S248080VX02
S248080VX11
S248092VX02
S248092VX03
S248092VX05
S248097VX05
S248097VX06
S248097VX08
S248106VX01
S248106VX02
S248106VX03
S248118VX02
S248118VX03
S248118VX05
S248124VX02
S248124VX03
S248124VX05
S248130VX02
S248130VX03
S248130VX05
S248142VX06
S248142VX07
S248142VX08

115
138
161
161
230
230
230
345
345
345
500
Notes:

Section
Length

Dry Arc

in [mm]

in [mm]

in

56.0
[1422]

42.8
[1087]

62.0
[1575]

48.8
[1240]

68.0
[1727]

54.8
[1392]

80.0
[2032]

66.8
[1697]

92.0
[2337]

78.8
[2002]

97.0
[2464]

83.8
[2129]

106.0
[2692]

92.8
[2357]

118.0
[2997]

104.8
[2662]

124.0
[3150]

110.8
[2814]

130.0
[3302]

116.8
[2967]

142.0
[3607]

128.8
[3272]

75.9
118.0
144.9
93.4
143.2
178.6
107.1
168.3
187.5
107.6
165.0
207.2
150.2
238.3
289.6
151.4
239.5
303.6
152.7
237.0
294.4
226.0
356.2
444.7
228.2
354.7
438.6
226.5
356.7
444.6
334.3
510.6
566.9

Leakage
[mm]

[1928]
[2997]
[3680]
[2372]
[3637]
[4536]
[2720]
[4275]
[4763]
[2733]
[4191]
[5263]
[3815]
[6053]
[7356]
[3846]
[6083]
[7711]
[3879]
[6020]
[7478]
[5740]
[9047]
[11295]
[5796]
[9009]
[11140]
[5753]
[9060]
[11293]
[8491]
[12969]
[14399]

Electrical Flashover (kV)


60 Hz
CIFO
Dry

Wet

Pos

Neg

422

379

726

771

479

428

820

869

479

428

820

869

536

476

913

964

765

657

1275

1334

813

692

1349

1409

898

766

1481

1544

1002

855

1656

1721

1046

899

1742

1808

1090

943

1829

1896

1178

1017

2002

2070

Weight
lbs

12.5
15.9
18.0
13.9
17.9
21.1
13.9
17.9
21.1
14.9
19.5
22.8
18.2
25.2
30.0
18.3
25.3
31.1
18.3
25.0
29.6
24.1
34.4
43.4
24.2
34.3
42.0
24.0
34.4
42.5
32.5
47.8
53.5

[kg]

[5.7]
[7.2]
[8.2]
[6.3]
[8.1]
[9.6]
[6.3]
[8.1]
[9.6]
[6.8]
[8.8]
[10.3]
[8.3]
[11.4]
[13.6]
[8.3]
[11.5]
[14.1]
[8.3]
[11.3]
[13.4]
[10.9]
[15.6]
[19.7]
[11.0]
[15.6]
[19.1]
[10.9]
[15.6]
[19.3]
[14.7]
[21.7]
[24.3]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.
For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-4 of SI-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Suspension Insulators

POWER
SYSTEMS
Rev: A1, Date: 02/2004

S4 Series Insulators
Insulator Strength Ratings
SML

S4

RTL

80 klb

40 klb

300 kN

150 kN

32mm Rod
Line
Voltage

"S4" Type
Catalog No.

kV

S499097VX05
S499097VX06
S499097VX07
S499106VX03
S499106VX04
S499106VX05
S499118VX04
S499118VX05
S499118VX06
S499124VX06
S499124VX07
S499124VX08
S499130VX03
S499130VX04
S499130VX05
S499142VX02
S499142VX03
S499142VX05
S499152VX05
S499152VX06
S499152VX07
S499165VX10
S499165VX11
S499165VX12
S499182VX06
S499182VX07
S499182VX08

230
230
345
345
345
500
500
500
500
Notes:

Section
Length

Dry Arc

in [mm]

in [mm]

in

97.0
[2464]

78.7
[1999]

106.0
[2692]

87.7
[2228]

118.0
[2997]

99.7
[2532]

124.0
[3150]

105.7
[2685]

130.0
[3302]

111.7
[2837]

142.0
[3607]

123.7
[3142]

152.0
[3861]

133.7
[3396]

165.0
[4191]

146.7
[3726]

182.0
[4623]

163.7
[4158]

149.4
138.7
296.4
153.2
237.2
294.9
228.2
354.2
432.9
228.9
354.9
444.2
229.7
355.7
439.7
330.9
414.9
540.9
335.7
414.9
587.7
332.9
416.9
642.7
334.2
418.2
643.9

Leakage
[mm]

[3795]
[3523]
[7529]
[3891]
[6025]
[7490]
[5796]
[8997]
[10996]
[5814]
[9014]
[11283]
[5834]
[9035]
[11168]
[8405]
[10538]
[13739]
[8527]
[10538]
[14928]
[8456]
[10589]
[16325]
[8489]
[10622]
[16355]

Electrical Flashover (kV)


60 Hz
CIFO
Dry

Wet

Pos

764

656

1272

849

719

1405

964

817

1581

1008

862

1668

1052

906

1755

1140

989

1927

1213

1042

2071

1308

1106

2257

1432

1179

2498

Neg

Weight
lbs

30.0
1332 35.8
39.6
30.7
1467 36.2
40.0
36.3
1645 44.5
49.7
36.6
1733 44.9
50.7
37.0
1821 45.3
50.8
44.3
1995 49.8
58.1
45.2
2140 50.3
61.7
45.7
2327 51.2
66.0
46.7
2569 52.2
67.0

[kg]

[13.6]
[16.2]
[18.0]
[13.9]
[16.4]
[18.1]
[16.5]
[20.2]
[22.5]
[16.6]
[20.4]
[23.0]
[16.8]
[20.5]
[23.0]
[20.1]
[22.6]
[26.4]
[20.5]
[22.8]
[28.0]
[20.7]
[23.2]
[29.9]
[21.2]
[23.7]
[30.4]

Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.
For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Suspension Insulators - Page SI-5 of SI-5


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Line Post Information

Rev: A1, Date: 02/2004

This Page of the


MacLean Power Systems
On-Line Catalog is currently
Under Construction

We expect this page to be active in the near future.

Please check again soon.

Line Post Information Page LP-I-1 of LP-I-1


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

H1-C1 Series Insulators: [2.0 Rod Dia.]

Fixed Gain Base

Drop Tongue Fixed Gain Base


Line
Voltage
kV

MDCL
lbs [kN]

1721
[7.7]

69

1401

69

[6.2]
1152

69

[5.1]
1042

115

[4.6]
913

115

[4.1]
821

138

[3.7]
728

161
Notes:

* Catalog No.

[3.2]

H1C1029VX01
H1C1029VX02
H1C1034VX01
H1C1034VX02
H1C1034VX03
H1C1040VX01
H1C1040VX02
H1C104VX03
H1C1044VX01
H1C1044VX02
H1C1044VX03
H1C1049VX01
H1C1049VX02
H1C1049VX03
H1C1054VX01
H1C1054VX02
H1C1054VX03
H1C1060VX01
H1C1060VX02
H1C1060VX03

Section
Length
in [mm]

29.0
[737]
34.0
[864]
40.0
[1016]
44.0
[1118]
49.0
[1245]
54.0
[1372]
60.0
[1524]

Dry Arc
in [mm]

in

49.5
74.5
44.6
26.8
74.6
[681]
89.6
45.8
32.9
70.8
[836]
90.8
79.9
37.0
119.9
[940]
144.9
80.0
42.1
120.0
[1069]
150.0
95.1
47.2
145.1
[1199]
180.1
53.4 106.2
166.2
[1356]
206.2
21.7
[551]

Electrical Flashover (kV)

Leakage
[mm]

[1257]
[1892]
[1133]
[1895]
[2276]
[1163]
[1798]
[2306]
[2029]
[3045]
[3680]
[2032]
[3048]
[3810]
[2416]
[3686]
[4575]
[2697]
[4221]
[5237]

60 Hz

CIFO

Dry

Wet

Pos

Neg

219

198

371

462

265

243

452

547

321

296

549

642

358

331

614

702

403

373

695

771

449

415

776

836

503

464

873

920

Weight
lbs

38.2
42.2
37.8
42.6
45.1
38.4
42.5
45.8
44.3
50.8
54.9
44.7
51.2
56.1
47.6
55.7
61.4
49.9
59.6
66.1

STL (Specified Tensile Load) 3,500 Lbs. [15.6 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

[kg]

[17.3]
[19.1]
[17.1]
[19.3]
[20.5]
[17.4]
[19.3]
[20.8]
[20.1]
[23.0]
[24.9]
[20.3]
[23.2]
[25.4]
[21.6]
[25.3]
[27.9]
[22.6]
[27.0]
[30.0]

Line Post Insulators Page LP-1 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

H1-C2 Series Insulators: [2.0 Rod Dia.]

Fixed Gain Base

Trunnion Fixed Gain Base


Line
Voltage
kV

1400

69

[6.2]
1152

69

[5.1]
1041
[4.6]

115

912

115

[4.1]
821

138

[3.7]
728

161

* Catalog No.

lbs [kN]

1720
[7.7]

69

Notes:

MDCL

[3.2]

H1C2029VX02
H1C2029VX04
H1C2034VX03
H1C2034VX05
H1C2034VX04
H1C2040VX01
H1C2040VX02
H1C2040VX03
H1C2044VX01
H1C2044VX02
H1C2049VX03
H1C2049VX04
H1C2049VX06
H1C2054VX04
H1C2054VX05
H1C2054VX06
H1C2060VX01
H1C2060VX02
H1C2060VX03

Section
Length
in [mm]

29.0
[737]
34.0
[864]
40.0
[1016]
44.0
[1118]
49.0
[1245]
54.0
[1372]
60.0
[1524]

Dry Arc
in [mm]

in

49.2
74.2
44.3
26.5
74.3
[673]
89.3
45.5
32.6
70.5
[828]
90.5
79.6
36.7
[932] 119.6
79.7
41.8
119.7
[1062]
149.7
94.8
46.9
144.8
[1191]
179.7
53.1 105.9
165.9
[1349]
205.9
21.4
[544]

Electrical Flashover (kV)

Leakage
[mm]

[1250]
[1885]
[1125]
[1887]
[2268]
[1156]
[1791]
[2299]
[2022]
[3038]
[2024]
[3040]
[3802]
[2408]
[3678]
[4564]
[2690]
[4214]
[5230]

60 Hz

CIFO

Dry

Wet

Pos

Neg

216

195

367

457

263

240

447

542

318

293

545

638

355

328

609

697

401

371

691

767

446

413

772

833

500

462

869

915

Weight
lbs

38.3
42.4
38.0
42.8
45.3
38.6
42.7
45.9
44.5
51.0
44.9
51.4
56.3
47.8
55.9
61.6
50.1
59.8
66.3

STL (Specified Tensile Load) 5,000 Lbs. [22.2 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

[kg]

[17.4]
[19.2]
[17.2]
[19.4]
[20.5]
[17.5]
[19.4]
[20.8]
[20.2]
[23.1]
[20.4]
[23.3]
[25.5]
[21.7]
[25.4]
[27.9]
[22.7]
[27.1]
[30.1]

Line Post Insulators Page LP-2 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

H1-91 Series Insulators: [2.0 Rod Dia.]

Bendable Gain Base

Drop Tongue Bendable Gain Base


Line
Voltage
kV

MDCL

Section
Length
in [mm]

H191029VX01
H191029VX02
H191029VX03
H191034VX01
H191034VX03
H191034VX04
H191040VX01
H191040VX03
H191040VX03
H191044VX01
H191044VX02
H191044VX03
H191049VX01
H191049VX02
H191049VX03
H191054VX01
H191054VX02
H191054VX03
H191060VX01
H191060VX02
H191060VX03

29.0

lbs [kN]

1760

69

[7.8]
1433

69

[6.4]
1174

69

[5.2]
1051

115

[4.7]
923

115

[4.1]
828

138

[3.7]
736

161
Notes:

* Catalog No.

[3.3]

[737]
34.0
[864]
40.0
[1016]
44.0
[1118]
49.0
[1245]
54.0
[1372]
60.0
[1524]

Dry Arc
in [mm]

in

50.1
75.1
[564]
80.1
50.2
27.3
75.2
[693]
90.2
46.3
33.5
71.3
[851]
91.3
80.4
37.5
120.4
[953]
145.4
80.5
42.7
120.5
[1085]
150.5
95.6
47.8
145.6
[1214]
180.6
53.9 106.7
166.7
[1369]
206.7
22.2

Electrical Flashover (kV)

Leakage
[mm]

[1273]
[1908]
[2035]
[1275]
[1910]
[2291]
[1176]
[1811]
[2319]
[2042]
[3058]
[3693]
[2045]
[3061]
[3823]
[2428]
[3698]
[4587]
[2710]
[4234]
[5250]

60 Hz
Dry

Wet

CIFO
Pos

Neg

224

203

380

471

270

248

460

555

326

301

558

650

362

335

623

709

408

378

704

778

453

420

785

843

507

469

882

928

Weight
lbs

36.1
40.1
41.0
36.5
40.6
43.0
36.4
40.4
43.7
42.2
48.7
52.8
42.7
49.1
54.0
45.5
53.6
59.3
47.8
57.6
64.0

STL (Specified Tensile Load) 7,000 Lbs. [31.1 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

[kg]

[16.4]
[18.2]
[18.6]
[16.6]
[18.4]
[19.5]
[16.5]
[18.3]
[19.8]
[19.1]
[22.1]
[23.9]
[19.4]
[22.3]
[24.5]
[20.6]
[24.3]
[26.9]
[21.7]
[26.1]
[29.0]

Line Post Insulators Page LP-3 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

NPKG Series Insulators: [2.5 Rod Dia.]

Fixed Gain Base


[To change from a gain
base to a flat base,
Change the G to a F as
per catalog definition]

Trunnion Fixed Gain Base


Line
Voltage

MDCL

kV

lbs [kN]

69

2500
[11.1]

69

Electrical Flashover (kV)


60 Hz
CIFO

Section
Length

Dry Arc

Leakage

in [mm]

in [mm]

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

NPKG30XH016S0

35.0
[889]

25.8
[655]

72.4
[1839]

256

234

436

530

45.3
[20.5]

2417
[10.8]

NPKG30XH020S0

40.9
[1039]

31.8
[808]

90.7
[2304]

311

287

532

626

49.4
[22.4]

115

2140
[9.5]

NPKG30XH023S0

45.4
[1153]

36.4
[925]

104.5
[2654]

352

325

604

692

52.4
[23.8]

115
138

1790
[8.0]

NPKG30XH028S0

52.8
[1341]

44.0
[1118]

127.5
[3239]

419

388

724

795

57.5
[26.1]

138

1573
[7.0]

NPKG30XH032S0

58.7
[1491]

50.0
[1270]

145.9
[3706]

473

438

821

869

61.5
[27.9]

138
161

1495
[6.7]

NPKG30XH034S0

61.7
[1567]

53.1
[1349]

155.1
[3940]

500

462

868

915

63.6
[28.8]

161

1337
[5.9]

NPKG30XH038S0

67.6
[1717]

59.1
[1501]

173.5
[4407]

553

510

964

1006

67.6
[30.7]

161

1280
[5.7]

NPKG30XH040S0

70.6
[1793]

62.1
[1577]

182.6
[4638]

579

533

1011 1051

69.6
[31.6]

230

1201
[5.3]

NPKG30XH043S0

75.0
[1905]

66.7
[1694]

196.4
[4989]

618

567

1082 1118

72.7
[33.0]

230

1055
[4.7]

NPKG30XH049S0

83.9
[2131]

75.8
[1925]

224.0
[5690]

696

635

1222 1251

78.8
[35.7]

Notes:

Catalog No.

STL (Specified Tensile Load) 5,000 Lbs. [22.2 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Weight

Line Post Insulators Page LP-4 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

NBKG Series Insulators: [2.5 Rod Dia.]

Bendable Gain Base


[To change from a gain base to
a flat base, Change the G to
a F as per catalog definition]

Trunnion Bendable Gain Base


Line
Voltage

MDCL

kV

lbs [kN]

69

2500
[11.1]

69

Electrical Flashover (kV)


CIFO
60 Hz

Section
Length

Dry Arc

Leakage

in [mm]

in [mm]

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

NBKG30XH016S0

35.2
[894]

25.8
[655]

72.4
[1839]

256

234

436

530

57.1
[25.9]

2492
[11.1]

NBKG30XH020S0

41.1
[1044]

31.8
[808]

90.7
[2304]

311

287

532

626

61.1
[27.7]

115

2191
[9.7]

NBKG30XH023S0

45.6
[1158]

36.4
[925]

104.5
[2654]

352

325

604

692

64.2
[29.1]

115
138

1826
[8.1]

NBKG30XH028S0

53.0
[1346]

44.0
[1118]

127.5
[3239]

419

388

724

795

69.2
[31.4]

138

1598
[7.1]

NBKG30XH032S0

58.9
[1496]

50.0
[1270]

145.9
[3706]

473

438

821

869

73.3
[33.2]

138
161

1521
[6.8]

NBKG30XH034S0

61.9
[1572]

53.1
[1349]

155.1
[3940]

500

462

868

915

75.3
[34.2]

161

1364
[6.1]

NBKG30XH038S0

67.8
[1722]

59.1
[1501]

173.5
[4407]

553

510

964

1006

79.4
[36.0]

161

1299
[5.8]

NBKG30XH040S0

70.8
[1798]

62.1
[1577]

182.6
[4638]

579

533

1011 1051

81.4
[36.9]

230

1220
[5.4]

NBKG30XH043S0

75.2
[1910]

66.7
[1694]

196.4
[4989]

618

567

1082 1118

84.4
[38.3]

230

1070
[4.8]

NBKG30XH049S0

84.1
[2136]

75.8
[1925]

224.0
[5690]

696

635

1222 1251

90.5
[41.1]

Notes:

Catalog No.

STL (Specified Tensile Load) 5,000 Lbs. [22.2 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

Line Post Insulators Page LP-5 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

Weight

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

NBSG Series Insulators: [2.5 Rod Dia.]

Bendable Gain Base


[To change from a gain base to
a flat base, Change the G to
a F as per catalog definition]

Drop Tongue Bendable Gain Base


Electrical Flashover (kV)
60 Hz
CIFO

Section
Length

Dry Arc

Leakage

in [mm]

in [mm]

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

NBSG30XH016S0

34.8
[884]

25.8
[655]

72.4
[1839]

256

234

436

530

54.4
[24.7]

2540
[11.3]

NBSG30XH020S0

40.7
[1034]

31.8
[808]

90.7
[2304]

311

287

532

626

59.3
[26.9]

115

2223
[9.9]

NBSG30XH023S0

45.2
[1148]

36.4
[925]

104.5
[2654]

352

325

604

692

61.1
[27.7]

115
138

1847
[8.2]

NBSG30XH028S0

52.6
[1336]

44.0
[1118]

127.5
[3239]

419

388

724

795

67.4
[30.6]

138

1619
[7.2]

NBSG30XH032S0

58.5
[1486]

50.0
[1270]

145.9
[3706]

473

438

821

869

71.4
[32.4]

138
161

1535
[6.8]

NBSG30XH034S0

61.5
[1562]

53.1
[1349]

155.1
[3940]

500

462

868

915

73.5
[33.3]

161

1380
[6.1]

NBSG30XH038S0

67.4
[1712]

59.1
[1501]

173.5
[4407]

553

510

964

1006

77.5
[35.2]

161

1308
[5.8]

NBSG30XH040S0

70.4
[1788]

62.1
[1577]

182.6
[4638]

579

533

1011

1051

79.5
[36.1]

230

1230
[5.5]

NBSG30XH043S0

74.8
[1900]

66.7
[1694]

196.4
[4989]

618

567

1082

1118

82.6
[37.5]

230

1076
[4.8]

NBSG30XH049S0

83.7
[2126]

75.8
[1925]

224.0
[5690]

696

635

1222

1251

88.7
[40.2]

Line
Voltage

MDCL

kV

lbs [kN]

69

3125
[13.9]

69

Notes:

Catalog No.

STL (Specified Tensile Load) 15,000 Lbs. [66.7 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Weight

Line Post Insulators Page LP-6 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

H2-91 Series Insulators: [2.5 Rod Dia.]

Bendable Gain Base

Drop Tongue Bendable Gain Base

Line

MDCL

Voltage
kV

lbs [kN]

1095

230

[4.9]
1019

230

[4.5]
979

230

[4.4]
907

230

Notes:

Catalog No.

[4.0]

H291081VX06
H291081VX05
H291081VX03
H291086VX09
H291086VX10
H291086VX11
H291090VX15
H291090VX16
H291090VX17
H291097VX07
H291097VX08
H291097VX09

Section
Length
in [mm]

81.0

Dry Arc
in [mm]

73.3

[2057]

[1862]

86.0

78.4

[2184]

[1991]

90.0

82.5

[2286]

[2096]

97.0

89.7

[2464]

[2278]

Electrical Flashover (kV)

Leakage
in

152.8
238.8
279.6
153.3
239.4
298.3
152.9
239.0
297.9
155.5
241.6
296.0

[mm]

[3881]
[6066]
[7102]
[3894]
[6081]
[7577]
[3884]
[6071]
[7567]
[3950]
[6137]
[7518]

60 Hz

Weight

CIFO

Dry

Wet

Pos

Neg

675

617

1184

1215

719

654

1262

1289

753

683

1324

1348

813

733

1431

1450

lbs

71.6
83.6
89.3
72.9
84.8
93.0
73.7
85.7
93.9
75.7
87.7
95.2

[kg]

[32.5]
[37.9]
[40.5]
[33.1]
[38.5]
[42.2]
[33.4]
[38.9]
[42.6]
[34.3]
[39.8]
[43.2]

STL (Specified Tensile Load) 15,000 Lbs. [66.7 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

For other ratings, designs with corona rings, or custom insulator designs, contact your local MPS Sales Representative.

Line Post Insulators Page LP-7 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

H3-91 Series Insulators: [3.0 Rod Dia.]

Bendable Gain Base

Drop Tongue Bendable Gain Base


Line
Voltage
kV

115
138
161
161
230
230
230
345
Notes:

MDCL

* Catalog No.

lbs [kN]

3263
[14.5]
2674
[11.9]
2239
[10.0]
2060
[9.2]
1852
[8.2]
1726
[7.7]
1671
[7.4]
1414
[6.3]

H391051VX06
H391051VX07
H391051VX08
H291060VX14
H391060VX15
H391060VX16
H391069VX05
H391069VX09
H391069VX10
H391075VX08
H391075VX06
H391075VX07
H391082VX04
H391082VX05
H391082VX01
H391087VX06
H391087VX07
H391087VX08
H391090VX25
H391090VX26
H391090VX27
H391104VX07
H391104VX08
H291104VX09

Section
Length
in [mm]

51.0

Dry Arc
in [mm]

39.3

[1295]

[998]

60.0

48.7

[1524]

[1237]

69.0

58.2

[1753]

[1478]

75.0

64.4

[1905]

[1636]

82.0

71.8

[2083]

[1824]

87.0

77.0

[2210]

[1956]

90.0

80.1

[2286]

[2035]

104.0

94.8

[2642]

[2408]

Electrical Flashover (kV)

Leakage
in

75.9
119.5
148.5
95.0
143.4
177.3
109.2
167.3
206.0
110.7
168.8
207.5
151.9
239.0
287.4
152.3
239.4
297.5
155.4
237.7
295.8
228.1
358.8
387.8

[mm]

[1928]
[3035]
[3772]
[2413]
[3642]
[4503]
[2774]
[4249]
[5232]
[2812]
[4288]
[5271]
[3858]
[6071]
[7300]
[3868]
[6081]
[7557]
[3947]
[6038]
[7513]
[5794]
[9114]
[9850]

60 Hz

CIFO

Dry

Wet

Pos

Neg

378

350

651

734

462

427

800

854

544

502

949

992

599

550

1047

1085

662

605

1160

1192

706

643

1240

1268

733

666

1288

1313

856

767

1505

1522

Weight
lbs

76.0
84.7
90.5
82.9
92.6
99.4
88.8
100.4
108.2
91.2
102.8
110.5
101.8
119.2
128.9
103.6
121.0
132.6
105.2
121.7
133.3
124.5
150.7
156.5

STL (Specified Tensile Load) 20,000 Lbs. [89.0 kN]


Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

[kg]

[34.5]
[38.4]
[41.1]
[37.6]
[42.0]
[45.1]
[40.3]
[45.5]
[49.1]
[41.4]
[46.6]
[50.1]
[46.2]
[54.1]
[58.5]
[47.0]
[54.9]
[60.1]
[47.7]
[55.2]
[60.5]
[56.5]
[68.4]
[71.0]

Line Post Insulators Page LP-8 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

Line Post Insulators

POWER
SYSTEMS
Rev: A2, Date: 04/2004

NBSG40XV Series Insulators: [3.5 Rod Dia.]

Bendable Gain Base


[To change from a gain base to
a flat base, Change the G to
a F as per catalog definition]

Drop Tongue Bendable Gain Base

Line
Voltage

MDCL

kV

lbs [kN]

115

5612
[25.0]

115
138
138
161

161
Notes:

Electrical Flashover (kV)


60 Hz
CIFO

Section
Length

Dry Arc

Leakage

in [mm]

in [mm]

in [mm]

Dry

Wet

Pos

Neg

lbs [kg]

NBSG40XV023S0

48.5
[1232]

36.4
[925]

95.6
[2428]

352

326

605

693

110.1
[49.9]

4672
[20.8]

NBSG40XV028S0

55.8
[1417]

44.0
[1118]

116.5
[2959]

420

389

725

796

118.0
[53.5]

3888
[17.3]

NBSG40XV034S0

64.6
[1641]

53.1
[1349]

141.5
[3594]

500

462

869

916

127.5
[57.8]

3505
[15.6]

NBSG40XV038S0

70.4
[1788]

59.2
[1504]

158.2
[4018]

553

510

964

1006

133.8
[60.7]

Catalog No.

STL (Specified Tensile Load 15,000 lbs. [66.8 kN] MDCL = Max. Design Cantilever Load
Electrical Data is without Corona Rings. For Insulators 230kV & Higher, MPS recommends use of Corona Rings.
NBSG40 Series Insulators for use in North American Market Only

For other ratings or custom insulator designs, contact your local MPS Sales Representative.

Weight

Line Post Insulators Page LP-9 of LP-9


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN
POWER
SYSTEMS

Station Post Information

Rev: A1, Date: 02/2004

This Page of the


MacLean Power Systems
On-Line Catalog is currently
Under Construction

We expect this page to be active in the near future.

Please check again soon.

Station Post Information Page SP-I-1 of SP-I-1


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

MACLEAN

High Voltage Station Posts SP200

POWER
SYSTEMS
Rev: A1, Date: 02/2004

NAA100XH Series Station Posts


For Systems from

69kV to 315kV
B.I.L.: 350kV --- 1050kV

A End Fittings = 5 Bolt Circle w/ 4 tapped holes


P End Fittings = 5 Bolt Circle w/ 4 through holes
Class 100 = 2.5 Solid Rod
HTV Silicone Rubber housing
Meets or Exceeds the ANSI C29.9 Electrical requirements
Tensile Strength = 17,500 lbs
Torsional Strength = 32,000 in-lbs
S1 = 12 Corona Ring (S0 = No Corona Ring)

Corona (grading) Ring: Recommended for most


applications with BIL 900kV. At lower voltages,
corona rings may be considered for areas of high local
contamination, and/or with altitudes > 3300 ft. Where
MPS considers them necessary, corona rings will be
included.

315 NAA100XH54S1
Notes:

308
312
316

inch

lbs.

kV

kV

kV

kV

lbs

30.0 26.8

72.0

38

350

145

200

44

45.0 37.4 106.1 46

550

230

200

54.0 46.5 133.7 49

650

275

200

62.0 54.1 156.7 60

750

80.0 68.0 211.8 52

900

inch

390 4400 2770

25k

0.7

73

610 2800 1750

12k

88

710 2300 1440

8k

315

200 103 810 2000 1260

6k

385

500 146 1010 1600

92.0 80.1 248.6 57 1050 455

500 146 1210 1400

990
870

3.4k
2.5k

1.9
2.9
2.6
4.0
3.1
4.8
4.6
7.0
4.8
8.6

SCL = Specified Cantilever Load, MDCL = Max. Design Cantilever Load


For P end fittings, replace the A with the P
To order Station Posts, contact your local MPS Sales Representative.
Station Posts for use in North American Market Only.

Station Post Insulators Page: SP200-1 0f SP200-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR MWL

lbs

@ 1 MHz

lbs

Max. RIV

Deflection

304

inch

Compression

295

inch

MDCL

291

SCL

289

CIFO +

230 NAA100XH46S1

288

Test Voltage
to ground

161 NAA100XH34S0

287

Low Freq.
withstand

138 NAA100XH29S0

286

BIL Rating

115 NAA100XH23S0

278

Weight

NAA100XH16S0

Leakage

69

Dry Arc

kV

Mechanical

Height

Catalog No.

Porcelain TR

Typical Line
Voltage

Electrical Characteristics

MACLEAN

High Voltage Station Posts SP200

POWER
SYSTEMS
Rev: A1, Date: 02/2004

NAA200XV Series Station Posts


For Systems from

69kV to 500kV
B.I.L.: 350kV --- 1470kV

A End Fittings = 5 Bolt Circle w/ 4 tapped holes


Class 200 = 3.5 Solid Rod
HTV Silicone Rubber housing
HIGH STRENGTH
Meets or Exceeds the ANSI C29.9 Electrical requirements
Tensile Strength = 25,500 lbs
Torsional Strength = 54,000 in-lbs
S1 = 12 Corona Ring (S0 = No Corona Ring)

Adaptor Plate
To comply with ANSI standards on 7 Bolt Circle fittings,
MPS has adopted the use of 1 adapter plates 5-7
shown here. The top adapter plate, when needed, has
integral slotted holes to facilitate alignment during erection
of bus supports.
The use of adaptor plates increases the height of the
insulators by 1 or 2. For retrofitting, it is possible to
adjust the total height to the original TR value.

Notes:

308

inch

lbs.

kV

kV

kV

kV

lbs

lbs

lbs

30.0 25.0

62.0

53

350

145

200

44

390

10k

inch
0.1

45.0 38.0

99.0

69

550

230

200

73

610 7100 4470

40k

54.0 44.7 117.5 77

650

275

200

88

710 6000 3630

35k

62.0 52.3 138.3 86

750

315

200 103 810 5160 3120

25k

80.0 66.2 188.4 110 900

385

500 146 1010 4000 2370

16k

7150 100k

0.2
0.5
0.7
0.7
1.1
0.9
1.4
4.6
7.0

SCL = Specified Cantilever Load, MDCL = Max. Design Cantilever Load


For custom Station Posts, contact your local MPS Sales Representative.
Station Posts for use in North American Market Only.

Station Post Insulators Page: SP200-2 0f SP200-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR MWL

inch

@ 1 MHz

inch

Max. RIV

Deflection

304

Compression

295

MDCL

291

SCL

289

CIFO +

230 NAA200XV45S1

288

Test Voltage
to ground

161 NAA200XV33S0

287

Low Freq.
withstand

138 NAA200XV28S0

286

BIL Rating

115 NAA200XV24S0

278

Weight

NAA200XV15S0

Leakage

69

216SP

Dry Arc

kV

Mechanical

Height

Catalog No.

Porcelain TR

Typical Line
Voltage

Electrical Characteristics

MACLEAN

High Voltage Station Posts SP200

POWER
SYSTEMS
Rev: A1, Date: 02/2004

NAA200XV Series Station Posts (contd)

A End Fittings = 5 Bolt Circle w/ 4 tapped holes


Class 200 = 3.5 Solid Rod
HTV Silicone Rubber housing
HIGH STRENGTH
Meets or Exceeds the ANSI C29.9 Electrical requirements
Tensile Strength = 25,500 lbs
Torsional Strength = 54,000 in-lbs
S1 = 12 Corona Ring (S0 = No Corona Ring)

Corona (grading) Ring: Recommended for most


applications with BIL 900kV. At lower voltages,
corona rings may be considered for areas of high local
contamination, and/or with altitudes > 3300 ft. Where
MPS considers them necessary, corona rings will be
included.

Notes:

kV

kV

lbs

lbs

lbs

inch
2.3
3.5
6.5
3.9
5.7
8.0
5.4
7.1
10.6

500 146 1210 3475 2020

12k

106.0 91.9 259.3 137 1300 525 1000 220 1410 3000 1760 8.5k

122.0 108.6 305.2 154 1470 590 1000 220 1610 2600 1480 6.5k

SCL = Specified Cantilever Load, MDCL = Max. Design Cantilever Load


For custom Station Posts, contact your local MPS Sales Representative.
Station Posts for use in North American Market Only.

Station Post Insulators Page: SP200-3 0f SP200-3


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.

@ TR MWL

Deflection

92.0 78.3 221.8 122 1050 455

Compression

Low Freq.
withstand

kV

MDCL

BIL Rating

kV

@ 1 MHz

Weight
lbs.

Max. RIV

Leakage
inch

SCL

500 NAA200XV73S1

inch

CIFO +

345 NAA200XV62S1

inch

Mechanical

Test Voltage
to ground

315 NAA200XV53S1

312
316
362
324
367
369
330
371
373

Dry Arc

kV

Height

Catalog No.

Porcelain TR

Typical Line
Voltage

Electrical Characteristics

MACLEAN
POWER
SYSTEMS

Braced Post Information

Rev: A1, Date: 02/2004

This Page of the


MacLean Power Systems
On-Line Catalog is currently
Under Construction

We expect this page to be active in the near future.

Please check again soon.

Braced Post Information Page BP-I-1 of BP-I-1


USA - Tel: 847-455-0014 Fax: 847-451-0029 y Canada - Tel: 450-698-0520 Fax: 450-692-5670 y www.macleanpower.com
Product specifications are subject to continuous improvement and may be changed at any time without notification.