INTRODUCTION
New Roof Construction Manual
Certi-labelTM Products
CONTENTS
Certi-label Products
pages 1-2
pages 3-5
page 6
page 7
page 7
pages 8-9
Roof Valley
Flashing Details
page 10
Roof Projection
Flashing Details
page 11
Roof Fastener
Guidelines
page 12
Ventilation Details
pages 13-14
Specialty Roof
Deck Details
page 15-16
pages 17-18
High Humidity
Area Details
page 19
Coverage &
Exposure Tables
page 20
pages 21-22
Specification Guidelines
pages 23-24
CERTI-LABEL PRODUCTS
CERTI-LABEL CEDAR SHAKES
Certi-Split Handsplit Shakes
CERTI-SPLIT
PREMIUM GRADE
100% Edge Grain
These shakes have split faces and sawn backs. Cedar logs are first cut into
desired lengths. Blanks or boards of proper thickness are split and then run
diagonally through a bandsaw to produce two tapered shakes from each
blank. Available in Premium Grade (100% edge grain) or Number 1 Grade
(Up to 20% flat grain allowed in each bundle).
PREMIUM GRADE
100% Edge Grain
These shakes are sawn both sides. Premium and Number 1 Grades are the
most common. Premium Grade is 100% edge grain, 100% clear and 100%
heartwood. Number 1 Grade allows up to 20% flat grain in each bundle.
Number 2 and 3 Grades are also available.
Certi-Split Tapersplit
CERTI-SPLIT
PREMIUM GRADE
100% Edge Grain
Produced by hand, using a sharp bladed steel froe and a mallet. The natural
shingle-like taper is achieved by reversing the block, end-for-end, with each
split. Premium Grade only.
Certi-Split Straight-Split
CERTI-SPLIT
PREMIUM GRADE
100% Edge Grain
The premium grade of shingles for roofs and sidewalls. These top-grade
shingles are 100% heartwood, 100% clear and 100% edge grain. Available
in 16" or 18" or 24" lengths.
Number 4 Undercoursing
A utility grade for undercoursing of double coursed sidewalls only. Not a
roofing material and not to be used as a starter course for roofs.
(604) 820-7700
CERTI-LABEL PRODUCTS
CERTI-GUARD
CERTI-GUARD
CERTI-LAST
Certi-label shakes
Spaced sheathing
Rafter
Eave protection
Fascia
Rafter header
Certi-label shakes
Solid sheathing
Gutter
Rafter
Eave protection
Fascia
Rafter header
Certi-label shingles
Solid sheathing
Gutter
Eave protection
Fascia
Rafter header
Rafter
4
Certi-label Shakes
Exposure
Product should
project 1 1/2"
beyond the fascia
and approximately 1"
over the gable or rake end
Spaced sheathing
should be
1 x 4 or 1 x 6
Solid sheathing at eave
Eave protection
Starter course
Rafter
Rafter header
Fascia
Space shingles
1/4" - 3/8" apart
Alternate course
joints should
not align
Eave protection
First course doubled or tripled
Rafter
Rafter header
Centerline of heart
Knot or
similar defect
NEW PIC
Certi-label shakes
Sheathing spaces are
multiples of exposures
plus 2 1/2"
Exposure
1 x 4 or 1 x 6
nailing strips
Gutter
Solid sheathing
Alternate overlap
8
Correct construction of roof junctures and
slope transitions is vital to ensure the integrity
of the roof system. In the following cases,
where metal flashing is employed, it should
be no less than 26 gauge galvanized steel or
acceptable equivalent. Check with your local
building official for their preference in your
area. It should be painted on both sides with a
good metal or bituminous paint. Flashing
materials should be painted after bending to
maintain the integrity of the coating.
Double or triple
starter course
Product should project
1 1/2" beyond the fascia
and approximately 1" over
the gable or rake end
Wood molding
Metal flashing
Sheathing
Convex Juncture
On this type of juncture (Figure 9) metal
flashings should be installed to cover the top
4" of the wall and the bottom 8" of the roof
slope before the final course of Certi-label
shakes or shingles is nailed to the top of the
wall. A strip of wood molding can be applied
after final wall course is installed. A double or
triple starter course is then applied at the
eave, with a 1 1/2" overhang over outside wall
trim. The roof can then be completed in the
normal manner.
Concave Juncture
Metal flashings for the concave juncture
(Figure 10) are similar to those for the convex
type. They should be installed to cover the top
of the roof slope and the bottom 4" of the
wall before the final course of Certi-label
shakes or shingles is installed. The final roof
course should be installed so that the tips fit
as snugly as possible against the wall at the
juncture. A double starter course should be
applied at the start of the wall surface and the
remaining wall courses applied in the
recommended manner. If nails are not
acceptable through exposed metal, metal clips
can be used to hold down flashing.
Metal flashing
Interwoven felt
for shakes only
Roof Transitions
Metal flashing
6" up - 6" below
Solid sheathing at
transition areas
Product should project
1 1/2" beyond the fascia and
approximately 1" over
the gable or rake end
Figure 11: Low Slope to Steep Slope Roof Transition Detail - Certi-label Shakes
(Certigrade shingle application is similar but without felt interlay)
Apex Juncture
On this roof juncture (Figure 12) metal
flashing should cover the top 8" of the roof
and the top 4" of the wall. It should be
installed before the final course of Certi-label
shakes or shingles is applied to the wall. The
recommended sequence of application is to
apply Certi-label shakes or shingles first to the
wall then to the roof. The overhanging roof
material is then trimmed flush with the wall.
Finally, specially prepared ridge units are
applied over the wall-roof juncture so that in
each matching pair the roof piece overlaps
the wall piece each time.
Ridge cap
Last course
over flashing
Metal
flashing
Sheathing
10
Eave protection
Eave protection
W valley metal
1/2" folded
back trim
W valley metal
W valley metal 1/2" crimp
Hidden felt
11
Bottom apron
flashing
Step flashing
3" laps
Certi-label
product
Bottom apron
flashing
Certi-label product
3" minimum
Bottom or
Apron flashing
Head flashing
6" minimum
Caulking
Caulking
3"
6"
Typical chimney
flashing requiring
soldering
Solder joints
Certi-label shake
or shingle joint
Counter flashing
Jack
Plumbing stack
12
Important Notes:
Underdriving or overdriving any
fastener will affect the integrity of
the roofing system.
Certi-Guard (fire-retardant-treated)
or Certi-Last (preservative-treated)
shakes and shingles:
ALWAYS ask the treatment company
which fasteners are recommended for
use with their pressure-treated Certilabel shakes or shingles. Some
fasteners are not compatible with
treated material.
YES
Correct - flush with surface
NO
Overdriven
Nails
Fasteners
Type of Certi-label
Shake or Shingle
NO
Underdriven
Type (in)
Staples
18" Straight-Split
5d Box 1 3/4
6d Box 2
24" Tapersplit
5d Box 1 3/4
6d Box 2
Certigrade Shingles
Type (in)
3d Box 1 1/4
24" Shingles
4d Box 1 1/2
VENTILATION DETAILS
Ventilation Guidelines
The importance of good attic ventilation beneath
the roof cannot be overemphasized. Such
movement of air will prevent or inhibit
condensation of moisture on the undersurface of
the Certi-label shakes or shingles, or on the roof
decks. Vents should be provided at the soffits
(eaves) as well as at gable ends (screened to
prevent ingress of insects), on roof by using attic
roof ventilation or preferably the ridge lines with
cross-ventilation desirable. A rule of thumb for
adequate ventilation is that the ratio of total net
free ventilation area to the area of the attic should
be not less than 1:150, with compensation made
for screens over vent apertures. In the case of a
balanced system a 1 square foot per 300 square
feet of floor area may be adequate ventilation.
Check with your local building department. Attic
fans may be beneficial, these supplying additional
movement of air in attic spaces. Several roof
ventilation construction techniques are shown in
Figures 15a-c.
Any modification to the vapor barrier system or
addition of a vapor barrier system should only be
done after consulting with your local building
official or a building envelope specialist. In some
areas, building envelope specialists are regulated
by government. Please check with local building
officials to see if there are professional
requirements in your area.
13
Ridge ventilation
product
Air flow
Louvered
vent at each
end of attic
Insulation
Continuous
screened vent
Louvered vent
at each end
of attic
Continuous
screened vent
Roof rafter
Insulation
Air flow
Air flow
Air flow
1-2" diameter screened
vents each roof
rafter space
Roof rafter
Air flow
Insulation
14
VENTILATION DETAILS
Ridge Vents
The amount of venting depends upon the size of
roofing material, roof design/structure (attic
present or not, etc.) as well as local climatic
conditions. Check with your local building
official for requirements in your area. One rule
of thumb for venting the attic area is
1 square foot per 150 square feet of floor area.
One half of this (1/2 square feet per 75 square
feet of floor area) amount should be in the soffit
or eave and one half (75 square feet) in the roof
system. In the case of a balanced system a
1 square foot per 300 square feet of floor area
may be adequate ventilation. Check with your
local building department.
Certi-ridgeTM
shake or shingle ridge
Ridge ventilation
product installed to
manufacturers
specifications
Roofing felt
Caulking
Airflow
through
ridge
Wooden deck
Joist
15
Air space
Nails
If the Certi-label shakes or shingles are nailed
directly through rigid insulation, a number of
problems may be encountered. For instance,
the longer nails have thicker shanks which
tend to split the Certi-label shakes or shingles.
16
Rigid Insulation
17
te
Ven
e
pac
ds
Spaced
sheathing
Trim
Vented space
Rafter
Insulation
Screen
Double starter
course
Decking
Screen
Rigid insulation
18
Wide overhangs at the eaves should be
avoided as they provide large cold areas for
snow and ice build-up. A strip of metal along
the eaves helps shed ice quickly. Sliding ice
and snow are constant hazards and should be
given primary consideration in the total
building design. Outside doors should not be
located at the bottom of a roof slope.
Entrances and all pedestrian traffic areas are
better situated beneath the gable ends of the
roof.
Care must be taken in applying the sheathing
boards to facilitate proper nailing. Shake or
shingle side lap should be increased to 2".
The entire roof must be laid with the same
precautions as those taken for any other type
of wood shake or shingle roof, with eave
protection and an interlay felt between
shakes.
ce
spa
ted
Ven
Screen
Insulation
Interior
finish
19
2 x 4 spacers
1 x 4 or 1 x 6
nailing strips
Shake
starter course
Solid sheathing
36" felt
underlay
Continuous ventilation
product
Shake
starter course
Solid sheathing
36" felt
underlay
20
Shingle Coverage Table 1
LENGTH AND
THICKNESS
16" x 5/2"
18" x 5/2 1/4"
24" x 4/2"
Approximate coverage of one square (4 bundles) of shingles based on following weather exposures
3 1/2"
70
4"
80
72 1/2
4 1/2"
90
81 1/2
5"
100*
90 1/2
5 1/2"
6"
6 1/2"
7"
7 1/2"
100*
73 1/2
80
86 1/2
93
100*
Approximate coverage (in sq. ft.) of one square, when shakes are applied
with an average 1/2 spacing, at following weather exposures, in inches (d):
5 1/2
75(b,f)
55(b,f)
Approx. 75(b)
65(b)
7 1/2
100(f,c)
75(f,c)
100(f,c)
75(e)
75(b)
75(b)
75(b)
75(b)
90(c)
75(b)
8 1/2
85
85
85
85
85
10
100(c)
100(c)
100(c)
100(c)
100(c)
Use supplementary with shakes applied not over 10" weather exposure.
(a) 5 bundIes will cover 100 sq. ft, roof area when used as starter-finish course at 10" weather
exposure; 7 bundles will cover 100 sq. ft. roof area at 7 1/2 weather exposure; see footnote (d).
(b) Maximum recommended weather exposure for 3-ply roof construction.
(c) Maximum recommended weather exposure for 2-ply roof construction.
(d) All coverage based on an average 1/2" spacing between shakes.
(e) Maximum recommended weather exposure.
*100 sq. ft. coverage is based on 12/12 pack, 5 bundle square, at 7 1/2 exposure.
21
22
Powerwashing
SPECIFICATION GUIDELINES
8. All solid sheathing shall be lumber or
This information has been designed to aid
structural panels applied according to
architects, consultants and builders in
specifications of the American Plywood
specifying Certi-label shakes and shingles. It
Association. Please note: the only solid
suggests a standardized terminology and style
sheet sheathing tested with shakes and
for ordering in the hope of improving accuracy.
shingles is plywood. Check with your local
It incorporates a general outline of the latest
building official for plywood thickness/
application information. Please note, however,
dimensions.
that this is a specification guide only. The
information in this manual is not intended
to supercede local building codes. Refer to Roofing Felt Interlay
local building codes for more information.
(for shakes only)
23
14. Premium and Number 1 Grade Certilabel shakes/shingles shall be applied
with the weather exposures consistent
with the following tables:
Maximum weather exposure
Shingle
3:12 to 4:12 4:12 and
length
roof slope
steeper
16"
3 3/4"
5"
18"
4 1/4"
5 1/2"
24"
5 3/4"
7 1/2"
24
17. Where saddles or crickets are formed in
back of chimneys, curves or similar
vertical surfaces, they shall be carried
not less than 10" under the Certi-label
shakes/shingles.
18. Step flashing shall be used where vertical
surfaces occur in connection with slopes.
They shall be formed of separate pieces.
Flashing shall extend horizontally not less
than 3" and up the vertical wall so that
they shall be lapped by the counter
flashing not less than 4". It shall be
installed in step fashion and each piece
shall lap not less than 3" (one flashing
installed on each course concealed under
the covering course). If other than
masonry is used the flashing shall extend
up the wall not less than 3" behind the
sheathing paper.
SPECIFICATION GUIDELINES
Valleys
Fasteners
23. Certi-label shakes/shingles extending into 29. Nails shall be driven flush but not so that
the nail head crushes the wood. They
the valley shall be sawed to the proper
shall be placed approximately 3/4" to 1"
miter.
from the side edges of the shakes/shingles
24. Do not lay shakes or shingles with grain
and approximately 1 1/2" above the butt
parallel with the centerline of valleys.
line of the following course.
25. All valleys shall be installed with Certilabel shakes/shingles lapping the valley
flashing not less than 7" on each side.
26. On Certi-label shingle roofs of less than
6:12 slope, flashing should extend at least
11 on each side.
Shingles:
1963,1998
NUMBER
25
004
GRADE
Litho in Canada
www.cedarbureau.org
Country of Manufacture
Mill Name
Mill Location
Mill Phone Number
PACKING
COVERAGE CHART
Heavy Resaws
24" x 3/4"
1.
2.
3.
4.
5.
BUNDLES
EXPOSURE
(610mm x 19 mm)
Canadian Address
#2 7101 Horne St.
Mission, BC
V2V 7A2
TEL: 604-820-7700
FAX: 604-820-0266
www.cedarbureau.org
info@cedarbureau.com
This manual shows Cedar Shake & Shingle Bureau recommended procedures as of
the manuals print date. It is advisable to contact the Cedar Shake & Shingle Bureau
to ensure that you are using the latest available information.
The CSSB logo (C with shingles/shakes), Blue Label, Certigrade, Certigroove,
Envirosmart are registered trademarks of the Cedar Shake & Shingle Bureau.
Certi-labelTM and other marks appearing in this manual are trademarks of the
Cedar Shake & Shingle Bureau.
November 2004