Вы находитесь на странице: 1из 13

Sewage Back Flushing and Changed Over 12 NM Record.

Person incharge :
Start of Change Over from
OVERBOARD to SEAWAGE
tk.12nm miles before Arr.
Date/Time

6/3/2012
2400hrs

7/8/2012
1100hrs

7/9/2012
1200hrs

7/14/2012
2340hrs

Position
(Lat/Long)

Start of Change Over from


SEAWAGE tk. To OVERBOARD
Over 12nm miles after
departure.
Date/Time

Position
(Lat/Long)

5/29/2012
2300hrs

14-14.6N
119-14.1E

7/4/2012
2200hrs

01-19.4S
105-06.6E

7/8/2012
1900hrs

05-49.5S
113-07.0E

7/10/2012
1600hrs

19-12.2S
115-44.5E

Start of Back Flushing Seawage


Treatment Plant over 12nm
miles.
Date/Time
5/29/2012
2300hrs

Position
(Lat/Long)
14-14.6N
119-14.1E

C/Engr. Robert E. Lana


Pollution Prevention Offi

Stop Back Flushing Seawage


Treament Plant.

Date/Time
5/29/2012
2330hrs

Position
(Lat/Long)
14-14.6N
119-14.1E

02-57.7N
104-53.9E
7/4/2012
2300hrs

01-14.2S
105-16.4E

7/4/2012
2300hrs

01-14.2S
105-16.4E

05-25.2S
112-27.4E

06.42.1S
114-23.8E

20-40.8S
115-48.1E

Footnote:
1. "No.6 DBWBCT (P)" Tank is used as Sewage and Gray Water Holding Tank.
2. This tank shall not be used as Ballast Water Tank accordingly.
3. C/E and C/O shall ensure that the vessel pipeline is switched to hold sewage and gray water into this tank before the vessel
Arriving within 12 nm of BWI.
4. For discharging of sewage and gray water, observe HOL-09-004 and Ship-Specific "Table of Discharging Rate".

Acknowledged by:

Capt: Reynaldo M. Mart

MASTER: M/V YAMAT

cord.
C/Engr. Robert E. Lanabe
Pollution Prevention Officer
4.0 m3 Average
Sewage Tank
Discharge Rate
Capacity 2.1 M3
per hour
Remarks

Always Checked and Dosed SK-5


Chem.Tablets to Seawage Treatment
Plant.

Always Checked and Dosed SK-5


Chem.Tablets to Seawage Treatment
Plant.

Always Checked and Dosed SK-5


Chem.Tablets to Seawage Treatment
Plant.

Capt: Reynaldo M. Martires


MASTER: M/V YAMATAI

Sewage and Grey water Holding Tank No. 6 DBWBCT (Port side)Discharging R
Person incharge :

Start Using Tank No.6


DBWBCT

Date/Time

Position
(Lat/Long)

Tank
Sounding
and
QUANTITY

7/14/12

20-40.8S

0.00m

2340hrs
7/19/12

115-48.1E
20-40.8S

2.4m
0.10m

1610hrs

115-48.5E

7.9m

Stop Using Tank No.6


DBWBCT

Date/Time
7/19/12
1524hrs

Position
(Lat/Long)
20-39.7S
115-49.5E

Tank
Sounding
and
QUANTITY
0.47m
29.5m

Sewage or
Gray
Water

Start Discharging of
seawage & Gray Water
Using ballast Pump.

Enter
"S" or "G"

Date/Time

S/G

7/19/12
1526hrs

Position
(Lat/Long)
20-39.7S
115-49.4E

Tank
Sounding
and
QUANTITY
0.47m
29.5m

Stop Discharging of
seawage & Gray Water
Using ballast Pump.
Date/Time
7/19/12
1534hrs

Position
(Lat/Long)
20-38.8S
115-50.1E

Tank
Sounding
and
QUANTITY
0.10m
7.4m

Footnote:
1. "No.6 DBWBCT (P)" Tank is used as Sewage and Gray Water Holding Tank.
2. This tank shall not be used as Ballast Water Tank accordingly.
3. C/E and C/O shall ensure that the vessel pipeline is switched to hold sewage and gray water into this tank before the vessel
Arriving within 12 nm of BWI.
4. For discharging of sewage and gray water, observe HOL-09-004 and Ship-Specific "Table of Discharging Rate".
5. Sewage Holding tank Overboard is Locked.
6. Seawage Holding tank Capacity is 2.1 m3 and Ave. discharge Rate of 5.0 m3 per hour.
7.Ballast pump capacity is 2,100m/H. Eductor capacity is 200m/H.
Acknowledged by:
8. Discharge of gray water tank using both ballast ang eductor.

Discharging Record.
C/Engr. Robert E. Lanabe
Pollution Prevention Officer
Speed

In Knots

Volume of
Draft (F&A) Discharge
d
in Meter

in M3

(Dischargi
ng Rate)

22.1m

221

F-4.48m
4 knots

A4.50m

Average
per hour

Capt: Reynaldo M. Martires

MASTER: M/V YAMATAI

Soil Holding Tank @ Main Engine Room Lower deck (Port side) Discharging Reco
Person incharge :

Start Using Soil


Holding Tank

Date/Time

Position
(Lat/Long)

Tank
Sounding
and
QUANTITY

Stop Using Soil


Holding Tank

Date/Time

Sewage or
Start Discharging Soil
Gray
Holding Tank
Water

Tank
Sounding
and
Position QUANTITY Enter
(Lat/Long)
"S" or "G"

Date/Time

Position
(Lat/Long)

Tank
Sounding
and
QUANTITY

Stop Discharging Soil


Holding Tank

Date/Time

Position
(Lat/Long)

Tank
Sounding
and
QUANTITY

C/Engr. Robe
Pollution Prev
Speed

In Knots

Footnote:
1. For discharging of sewage and gray water, observe HOL-09-004 and Ship-Specific "Table of Discharging Rate".
2. Sewage Soil Holding tank Overboard is Locked.(Not Using since March 15, 2012)

Acknowledged by:

Capt: Reynald

MASTER: M

harging Record.
C/Engr. Robert E. Lanabe
Pollution Prevention Officer
Volume of
Draft (F&A) Discharge
d
in Meter

in M3

Average
per hour
(Dischargi
ng Rate)

Capt: Reynaldo M. Martires


MASTER: M/V YAMATAI

SEWAGE & GRAY WATER TREATMENT SYSTEM


CHECKLIST OF CHANGED-OVER VALVE

Person incharge :

PLACE:

Pollution Prevention Officer


LAT:

DATE:

POSITION:

TIME:
LOCATION

C/Engr. Robert E. Lanabe

LONG:

DESCRIPTION

KIND OF VALVES

NO.

150A GATE VALVE

1. INSIDE PIPE DUCT

INLET TO GRAY WATER TANK

2. AUX. E/R (P) SIDE

TO GRAY WATER TANK

50A GATE VALVE

3. AUX. E/R (P) SIDE

SEWAGE TREATMENT TANK OVERBOARD

50A GATE VALVE

4. AUX. E/R (P) SIDE

TO GRAY WATER TANK

65A GATE VALVE

5. AUX. E/R (P) SIDE

DRAIN OVERBOARD (DISPOSER)

80A GATE VALVE

6. AUX. E/R (P) SIDE

TO GRAY WATER TANK

80A GATE VALVE

7. AUX. E/R (P) SIDE

DRAIN OVERBOARD (PROV.REF.CHAMBER)

80A GATE VALVE

8. AUX. E/R (P) SIDE

TO GRAY WATER TANK

65A GATE VALVE

9. AUX. E/R (P) SIDE

MAIN DRAIN OVERBOARD

150A GATE VALVE

10. AUX. E/R (S) SIDE

TO GRAY WATER TANK

65A GATE VALVE

10

11. AUX. E/R (S) SIDE

MAIN DRAIN OVERBOARD

150A GATE VALVE

11

12. AUX. E/R (P) SIDE

DRAIN(PROV.REF.CHAMBER)

80A STORM VALVE

324VPS

13. AUX. E/R (P) SIDE

DRAIN (DISPOSER)

80A STORM VALVE

326VPS

14. AUX. E/R (P) SIDE

MAIN DRAIN OVERBOARD

150A STORM VALVE

322VPS

15. AUX. E/R (P) SIDE

SEWAGE TREATMENT TANK OVERBOARD

50A STORM VALVE

338VPS

16. AUX. E/R (S) SIDE

MAIN DRAIN OVERBOARD

150A STORM VALVE

302VPS

POSITION

Acknowledged by:

CONDITION

Capt: Reynaldo M. Martires


MASTER: M/V YAMATAI

CHECKED BY

MAXIMUM DISCHARGING RATE OF UNTREATED SEWAGE IN ACCORDANCE WITH


RESOLUTION MEPC.157(55)
SHIP'S NAME :

M/V "YAMATAI"

IMO Number :

9567714

Breadth :

38.0 meters

Min. Draft :

2.39 meters

Max. Summer Draft :

6.4 meters

Max. Service Speed :

13.25 Knots

Theoretical Max. Rate :

29.70 M3/hour

Vessel Sewage and Gray Water Holding Holding Tank ( 6 DBWBCT(P) Cap. 116.6 M3 )
The calculated discharge rate refers to the average rate as calculated over any 24 hrs. period, or the period of
discharge whichever is lower, and is not to be exceeded by more than 20% when measured on any hourly basis.
The permissible rate of discharge is reduce at draft and/or speed. See the table below

DISCHARGING RATE
SPEED (Knots)
DRAFT (Meter)
2.39
3.00
4.50
5.00
6.00
6.37

4.0 kts

6.0 kts

8.0 kts

10.0 kts

3.36

5.05

6.73

8.41

4.22

6.33

8.45

10.56

6.33

9.50

12.67

15.83

7.04

10.56

14.08

17.59

8.45

12.67

16.89

21.11

8.97

13.45

17.93

22.41

Drmax = 0.00926VDB

by more than 20% when measured on any hourly basis.

DISCHARGING RATE
12.0 kts

13.25 kts

10.09

11.14

12.67

13.99

19.00

20.98

21.11

23.31

25.34

27.97

26.90

29.70

Вам также может понравиться