Академический Документы
Профессиональный Документы
Культура Документы
Equipment
Vibration
Ultrasound
Oil Analysis
N/A
N/A
N/A
N/A
UNIT- 1
Turbine
N/A
N/A
N/A
Vacuum Pump A
N/A
Vacuum Pump
Gearbox B
Vacuum Pump B
CT Gearbox A
N/A
N/A
N/A
CT Gearbox B
N/A
CT Gearbox C
N/A
CT Gearbox D
N/A
CT Gearbox E
N/A
CT Gearbox F
N/A
CT Gearbox G
N/A
CT Gearbox H
N/A
UNIT- 2
N/A
N/A
Turbine
Hot Well Pump A
N/A
N/A
N/A
N/A
N/A
N/A
Vacuum Pump
Gearbox A
Vacuum Pump A
N/A
Vacuum Pump
Gearbox B
Vacuum Pump B
N/A
CT Gearbox A
N/A
CT Gearbox B
N/A
CT Gearbox C
N/A
CT Gearbox D
N/A
CT Gearbox E
N/A
CT Gearbox F
N/A
CT Gearbox G
N/A
CT Gearbox H
N/A
Plant Utilities
Main Fire Pump
N/A
N/A
N/A
N/A
N/A
Thermal Pond B
N/A
Thermal Pond C
N/A
MBD PUMP A
N/A
MBD PUMP B
N/A
Recommendation
Priority
N/A
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
Continue Monitoring
3
Repair Next Shutdown
Monthly Report
-III-2014
Rotating Equipment
Remark / Concern
Vibration : Increasing amplitude at Bearing #1 & #4 (filtered orbit)
Oil Analysis : Based on november 2013 result. Next sampling : July 2014 or 6 month
after replacement on Feb 2014
Vibration : impacting on p1 bearing
Ultrasound : impacting on P1 bearing
Oil Analysis : due to new gearbox, next sampling will be 4 month after first oil
replacement
Oil Analysis : based on january 2014 report. Next sampling : May 2014
Vibration : Still fluctuating ; the highest amplitude 9 mm/s pk
Oil Analysis : not sampled, due to new gearbox. Next sampling : April 2014
Oil Analysis : Result after filtering : 23/22/16 from 23/23/18 altough particle quantity
has been reduced, condition still out of tolerance for >4 and >6 micron. Oil need to
replaced
Oil Analysis : due to new gearbox, next sampling will be 4 month after first oil
replacement
Vibration : Fluctuating, the highest amplitude 12 mm/s pk
Oil Analysis : after re-sampling, the result is within the limit. Changing oil is
unnecesary. Next sampling : April 2014
Vibration : Fluctuating, the highest amplitude 9 mm/s pk
Oil Analysis : based on January 2014 report. Next sampling : April 2014
Oil Analysis : after re-sampling, the result is within the limit. Changing oil is
unnecesary. Next sampling : April 2014
Oil Analysis : Based on february 2014 result. Next sampling : October 2014 or 6
month after replacement on April 2014
Oil Analysis : Based on february 2014 result. Next sampling : October 2014 or 6
month after replacement on April 2014
Month :
Mar 2014
Report Reference :
CM-R-MR-0100-III-2014
Page 3
Page 5
Page 6
Page 10