coherent
efficient
compact
S830
V E RT I C A L / H O R I Z O N TA L
TA N G E N T A R R AY
MODULE
PRODUCT FEATURES
Optimized for use in tangent arrays.
Integral high-precision array asembly system.
High power, long excursion neodymium 8 inch
woofer delivers full range output from
compact enclosures.
406mm
16
S805 Vertical
output.
The GEO S Series is the result of a three year intensive R&D
project that has produced three fundamental patent
applications in loudspeaker technology. The performance
advantages produced by GEO innovations are easily
measurable and clearly audible. With two full range tangent
NX241 Digital TDController
w w w . n e x o - s a . c o m
GEO Tangent
Array Modules
can be used in
horizontal or
vertical arrays,
with or without
the CD12
Controlled
Directivity
Subbass
flexible
coherent
efficient
compact
PRODUCT FEATURES
Components:
LF
HF:
Shape
30 Trapezoid
Weight:
Net
Connectors
Construction
Baltic Birch Ply, structured black coating (dark grey carpet also available).
Fittings:
S830
V E RT I C A L / H O R I Z O N TA L
TA N G E N T A R R AY
MODULE
Grill
Perforated Steel
Flying
Integral flying system with angle adjustments of .31 to 5 (logarithmic steps), 17.5 & 30
67 Hz 19 kHz 3 dB
60 Hz 20 kHz
Sensitivity 1W @ 1m [b]
125 to 128 dB Peak for a single cabinet. Configuration dependant when arrayed [d].
Dispersion [c]
Coupling Plane:
Non-Coupling Plane:
DI = 12 Nominal (f > 1.5 kHz) for 1x S830. Configuration dependant when arrayed [d].
Crossover Frequency
Nominal Impedance
16 Ohms
Recommended Amplifiers 1500 to 3000 Watts into 4 Ohms / 4 cabinets per channel. Up to 6 cabinets per channel may be connected to
large amplifiers capable of operating into low impedance loads.
SYSTEM OPERATION
Electronic Controller
The NX241 Digital TDController presets are precisely matched to the GEO S8-Series cabinets and include
sophisticated protection systems. Using GEO S8-Series cabinets without a properly connected NX241 Digital
TDController will result in poor sound quality and can damage components. The GEO S830 & S830 can be
used without the optional CD12 Hypercardiod Sub. In this case the NX241 can be used in stereo. With the
CD12 Hypercardiod Sub each Sub channel requires two NX241 outputs and the NX241 will operate in mono.
HF Dispersion Configuration After quick release of the front grill from its fittings, the HF Waveguide can be configured for 80 or 120
dispersion in the non-coupling plane.
Array Design
S830 and S805 cabinets, having tangent waveguides, can be mixed in the same array. Minimum
configuration for Vertical Tangent Arrays is 5x S830 & 1x S830 (4x S830 for paging applications only). CD12s
are optional: a ratio of 1 CD12 per 3 full range GEO modules is required for proper subbass output.
Speaker Cables
The GEO S830 and S830 are wired 1- & 1+ on both Speakon connectors, 2- & 2+ are not connected.
Rigging System
NEXO S.A.
154 alle des Erables
ZAC de PARIS NORD II B.P. 50107
F-95950 Roissy CDG CEDEX
France
Shipping Weight & Volume 2x S830s: 28 kg (61.7 lbs) 0.135 cu m (4.8 cu ft)
As part of a policy of continual improvement, NEXO reserves the right to change specifications without notice.
[a] Response Curves and Data: Anechoic Far Field above 200 Hz, Half-space Anechoic below 200 Hz. Usable Range Data: Frequency Response
Capability with TD crossover slopes removed.
[b Sensitivity & Peak SPL: will depend on spectral distribution. Measured with band limited Pink Noise. Refers to the specified +/- 3 dB
range. Data are for Speaker + Processor + recommended amplifier combinations.
[c] Directivity Curves and Data: 1/3 octave smoothed frequency response, normalized to On-Axis response. Data obtained by computer processing of offaxis response curves.
[d] Please refer to the GEO User Manual.
219 mm
406 mm
250 mm
30
LIMITED WARRANTY
Nexo loudspeakers and electronics are covered against defects in workmanship or materials for a period of two (2) years from the original date of purchase. At the option of Nexo, the defective item will be
repaired/replaced with no charge for materials/labor. The item is to be adequately packaged and dispatched, pre-paid, to a Nexo authorized distributor/service center. Unauthorized repair shall void the warranty.
This Nexo warranty does not cover cosmetics or finish and does not apply to any items which in Nexos opinion have failed due to user abuse, accidents, modifications or any type of misuse.
w w w . n e x o - s a . c o m
Tl: +33 1 48 63 19 14
Fax: +33 1 48 63 24 61
E-mail: info@nexo.fr
Nexo USA, Inc.
2165 Francisco Blvd.
Suite E2
San Rafael, CA 94901
Phone: +1 415 482 6600
Fax: +1 415 482 6110
E-mail: info@nexo.cc
NEXO Far East Pte Ltd
No. 10 Ubi Crescent
#02-35/36 Ubi Techpark (Lobby C)
Singapore 408564
Tel: +65 742 5660
Fax: +65 742 8050
E-mail: info@nexo-sg.com
flexible
coherent
efficient
compact
S805 VERTICAL
TA N G E N T A R R AY
MODULE
PRODUCT FEATURES
Optimized for use in vertical tangent arrays.
Integral high-precision array asembly system.
High power, long excursion neodymium 8 inch
woofer delivers full range output from
compact enclosures.
406mm
16
S805 Vertical
w w w . n e x o - s a . c o m
GEO Tangent
Array Modules
can be used in
horizontal or
vertical arrays,
with or without
the CD12
Controlled
Directivity
Subbass
flexible
coherent
efficient
compact
PRODUCT FEATURES
Components:
LF
HF:
Shape
5 Trapezoid
Weight:
Net
S805 VERTICAL
TA N G E N T A R R AY
MODULE
Connectors
Construction
Baltic Birch Ply finish with structured black coating. Dark grey carpet finish also available.
Fittings:
Grill
Perforated Steel
Flying
Integral flying system. Intercabinet Angle Adjustments = .31 to 5 (logarithmic steps), 17.5 & 30
67 Hz 19 kHz 3 dB
60 Hz 20 kHz
Sensitivity 1W @ 1m [b]
125 to 128 dB Peak for a single cabinet. Configuration dependant when arrayed [d].
Dispersion [c]
Coupling Plane:
Non-Coupling Plane:
Crossover Frequency
Nominal Impedance
16 ohms
Recommended Amplifiers 1500 to 3000 Watts into 4 ohms / 4 cabinets per channel. Up to 6 cabinets per channel may be connected to
large amplifiers capable of operating into low impedance loads.
SYSTEM OPERATION
Electronic Controller
The NX241 Digital TDController presets are precisely matched to the GEO S8-Series cabinets and include
sophisticated protection systems. Using GEO S8-Series cabinets without a properly connected NX241 Digital
TDController will result in poor sound quality and can damage components. The GEO S805 & S830 can be
used without the optional CD12 Hypercardiod Sub. In this case the NX241 can be used in stereo. With the
CD12 Hypercardiod Sub each Sub channel requires two NX241 outputs and the NX241 will operate in mono.
HF Dispersion Configuration After quick release of the front grill from its fittings, the HF Waveguide can be configured for 80 or 120
dispersion in the non-coupling plane.
Array Design
S805 and S830 cabinets, having tangent waveguides, can be mixed in the same array. Minimum
configuration for Vertical Tangent Arrays is 5x S805 & 1x S830 (4x S805 for paging applications only). CD12s
are optional: a ratio of 1 CD12 per 3 full range GEO modules is required for proper subbass output.
Speaker Cables
The GEO S805 and S830 are wired 1- & 1+ on both Speakon connectors, 2- & 2+ are not connected.
Rigging System
NEXO S.A.
154 alle des Erables
ZAC de PARIS NORD II B.P. 50107
F-95950 Roissy CDG CEDEX
France
Shipping Weight & Volume 2x S805s: 29.2 kg (64.2 lbs) 0.135 cu m (4.8 cu ft)
As part of a policy of continual improvement, NEXO reserves the right to change specifications without notice.
[a] Response Curves and Data: Anechoic Far Field above 200 Hz, Half-space Anechoic below 200 Hz. Usable Range Data: Frequency Response Capability with
TD crossover slopes removed.
[b] Sensitivity & Peak SPL: will depend on spectral distribution. Measured with band limited Pink Noise. Refers to the specified +/- 3 dB range. Data are for
Speaker + Processor + recommended amplifier combinations.
[c] Directivity Curves and Data: 1/3 octave smoothed frequency response, normalized to On-Axis response. Data obtained by computer processing of offaxis response curves.
[d] Please refer to the GEO User Manual.
250 mm
219 mm
406 mm
LIMITED WARRANTY
Nexo loudspeakers and electronics are covered against defects in workmanship or materials for a period of two (2) years from the original date of purchase. At the option of Nexo, the defective item will be
repaired/replaced with no charge for materials/labor. The item is to be adequately packaged and dispatched, pre-paid, to a Nexo authorized distributor/service center. Unauthorized repair shall void the warranty.
This Nexo warranty does not cover cosmetics or finish and does not apply to any items which in Nexos opinion have failed due to user abuse, accidents, modifications or any type of misuse.
w w w . n e x o - s a . c o m
Tl: +33 1 48 63 19 14
Fax: +33 1 48 63 24 61
E-mail: info@nexo.fr
Nexo USA, Inc.
2165 Francisco Blvd.
Suite E2
San Rafael, CA 94901
Phone: +1 415 482 6600
Fax: +1 415 482 6110
E-mail: info@nexo.cc
NEXO Far East Pte Ltd
No. 10 Ubi Crescent
#02-35/36 Ubi Techpark (Lobby C)
Singapore 408564
Tel: +65 742 5660
Fax: +65 742 8050