Вы находитесь на странице: 1из 6

4G

Project

OSP Engineering - RJIL

10070-40-PSS-PR-EF-025

FRP Manhole (900 (W)X900(L)X1200(D)) Grade HD-20

Amendment Record / Control Sheet (ACS)

Rev.
No.

Date

Reason
for Issue

Issued for
use
Revised &
01 19-03-13 Reissued For
Use
00

02

04-02-13

Revised &
10-04-13 Reissued for
use

Rev. 02

Prepared Reviewed Approved


by
by
by

Issued
by

Details of Amendments /
Revisions

KRS

MPS

KKS

KKS

Not Applicable

KRS

MPS

KKS

KKS

FRP Manhole covers


details.

KRS

MPS

KKS

KKS

Angle for the manhole


frame & MH Cover Thk

Issue date : 10-04-13

Page 2 of 4

OSP Engineering - RJIL

4G
Project

10070-40-PSS-PR-EF-025

FRP Manhole (900 (W)X900(L)X1200(D)) Grade HD-20

INDEX

SCOPE ................................................................................................................................................ 4

DESIGN ............................................................................................................................................... 4

INSPECTION AND TESTING ............................................................................................................. 4

REFERENCE DRAWING .................................................................................................................... 4

Rev. 02

Issue date : 10-04-13

Page 3 of 4

4G
Project

OSP Engineering - RJIL

10070-40-PSS-PR-EF-025

FRP Manhole (900 (W)X900(L)X1200(D)) Grade HD-20

SCOPE
This document covers design of FRP manholes with concrete covers for use in
Intracity OFC Networks.

DESIGN
i

The Manholes shall be steel structural frame with a layer of FRP covering
entire structure and void spaces between structural steel frames suitable for
grade HD-20 as per IS-12592.

ii

Covers shall be M30 concrete with adequate reinforcement as per


manufactures design.

iii

Design shall be approved and validate through testing by independent


Agency / Test house like IIT.

iv

The provision shall be made in design for Entry and Exit of duct and existing
Utilities.

Cover shall be design and Tested as per I.S.12592 for Grade HD-20.

vi

The Manufacturer to qualify manufacturing process for Steel, FRP and


concrete and provided Inspection and Test plan and other manufacturing
parameters.

INSPECTION AND TESTING


Manufacture shall be establish an Inspection and Testing plan and get it approval
from Engineer-In-Charge prior to start of production.

REFERENCE DRAWING
Drawings and Document only approved by IIT Mumbai for one of the Manufacturer
are attached for reference as following:
i
ii
iii
iv

Rev. 02

Design dossiers for 900X900X1200mm.


Test Report of Manhole Cover (Not yet received)
Manhole design drawing 10004.
FRP Manhole cover details.
The above drawing and document submitted by manufacturer M/S Anupam
Fibro-tech have been Review by company and found to be order and good to
use subject to submission of final Test Reports.Test to be conducted in the
presence of IIT Mumbai Professor: Dr. R.S. Jangid
Issue date : 10-04-13

Page 4 of 4

Вам также может понравиться