Вы находитесь на странице: 1из 51

Company Business

Zamil Air Conditioners was founded in 1974, and is the first major business venture in manufacturing sector for the Al
Zamil group of Companies. It is also the first manufacturing unit for air conditioners to be established in Saudi Arabia.
Zamil Air conditioners manufactures both consumer and central range of air conditioners and has sales operations in
over 55 countries in the Middle East, Europe, America, Africa, Australia and the Far East.
The companys operations are structured into four Strategic Business Units (SBUs) supporting six in - house product and
service brands as well as a number of international brands under the OEM sales.
The six in-house brands are Classic, Cooline, CoolCare, Clima Tech, Geoclima and Kessler Clima Tech.
The four SBUs are:
1. Consumer Business unit supporting Classic, Cooline, GE and OEM brands for consumer range of air conditioners.
2. Unitary & Applied Business unit supporting Classic, Cooline, GE and OEM brands for commercial range of air
conditioners.
3. Zamil CoolCare - service and maintenance provider.
4. Geoclima srl - independent business and supporting other SBUs for their requirement of Chillers & Double skin
AHUs.
The first three SBUs - Consumer Products, Unitary & Applied Products and Zamil CoolCare direct their business operations from the corporate headquarters at Dammam, Saudi Arabia.
The production facilities at Dammam are shared by Consumer Products and Unitary & Applied Products. Geoclima has
its own production and functional departments located at Monfalcone, Italy.
All the four SBUs, while operating independently, supplement each others activities in a way that makes synergy work at
its best and achieve the corporate goals of increased productivity and efficiently.
Factories and Productions
Zamil Air Conditioners has its prime manufacturing base at Dammam, Saudi Arabia and has one speciality production
facility in Italy operated by Geoclima.
The company can produce up to 440,000 room air conditioners, 60,000 mini-split systems and 36,500 central air-conditioning systems per year.
Quality & Product Certificates
The Quality systems and policies at Zamil Air Conditioners comply with the required ISO 9001:2000 certification.
Zamil Air Conditioners is the first company in Saudi Arabia to receive the SASO (Saudi Arabias Standard Organization)
certificate for room air conditioners. Its products and services are also certified with:
1.
2.
3.
4.
5.
6.

CE (Council of European Community)


UL (Underwriters Laboratory)
AHAM certificate (Association of Home Appliance Manufacturers)
Eurovent
DEMKO
ETL

Other awards include the prestigious Engineering Excellence Award of General Electric, and the inaugural Prince
Mohammed bin Fahd Al Saud Award for Factory Safety.
Our Products
In addition to the consumer products such as the Room Air Conditioners (RAC) and the Mini Splits, Zamil Air Conditioners manufacturers a host of residential and commercial air conditioners. This board range extends from the concealed
units up to 5 ton, the ducted splits up to 30 tons, the packaged units up to 70 tons. The single and double skin air handling
units up to 130,000 CFM and the water chillers up to 487 ton cooling capacity.

INDEX
Contents

Page

Model decoding ........................................................................................................................................ 2


Standard specifications/options/accessories ......................................................................................... 3-7
Physical data ............................................................................................................................................ 8
Selection procedure ................................................................................................................................. 9
Cooling capacities ............................................................................................................................. 10-15
Electrical data .................................................................................................................................... 16-22
Fan performance data ....................................................................................................................... 23-30
Sound level data ................................................................................................................................ 31-33
Static pressure drop ............................................................................................................................... 34
Unit dimensions ................................................................................................................................. 35-37
Rigging instructions and weight distribution ........................................................................................... 38
Typical schematic wiring diagram ...................................................................................................... 39-43
Installation instructions ........................................................................................................................... 44
Recommended spare parts .................................................................................................................... 45

CONTINUING RESEARCH RESULTS IN STEADY IMPROVEMENTS.


THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
1

+
++

*
**
***

NOTES:

MODULAR
PACKAGED
UNITS

PMY

1, 2 & 3
BASIC

F : 460-3-60

M : 380-3-60
(4 WIRE)

H : DUAL SEMIHERMETIC
RECIPROCATING

S : SINGLE SEMIHERMETIC
RECIPROCATING

*
**

8
REFRIGERATION
CIRCUIT TYPE

H : 208/230-3-60 D : DUAL SCROLL

7
ELECTRICAL
SUPPLY
( V-Ph-Hz )

C : COPPER FIN

B : COATED
ALUMINUM
FIN

A : ALUMINUM
FIN

9
CONDENSER
COIL

M : COPPER FIN WITH DRIP


ELIMINATOR++

K : COATED ALUMINUM FIN


WITH DRIP ELIMINATOR++

D : ALUMINUM FIN WITH DRIP


ELIMINATOR++

C : COPPER FIN WITH OUT DRIP


ELIMINATOR++

B : COATED ALUMINUM FIN


WITH OUT DRIP
ELIMINATOR++

A : ALUMINUM FIN WITH OUT


DRIP ELIMINATOR++

10
EVAPORATOR COIL

M : TOP SUPPLY
AIR & SIDE
RETURN AIR

T : TOP SUPPLY
AIR & TOP
RETURN AIR

K: FRONT
SUPPLY AIR &
SIDE RETURN
AIR

F : FRONT
SUPPLY AIR &
TOP RETURN
AIR

11
SUPPLY &
RETURN
AIRFLOW
(kW/STAGES)

13
HEATER
OPTIONS

14
KITS
MECHANICAL &
ELECTRICAL
OPTIONS

V : 30HP TEFC

U : 30HP ODP

T : 25HP TEFC

S : 25HP ODP

R : 20HP TEFC

Q : 20HP ODP

P : 15HP TEFC

N : 15HP ODP

M : 10HP TEFC

L : 10HP ODP

P : 60/2

M : 50/2

L : 40/2

J : 30/2

H : 25/2

G : 20/2

F : 15/2

K : 7.5HP TEFC D : 10/2

***

H : B, C, D & S COMBO

Q : P, V, S & A COMBO

T : P, V, D & A COMBO

R : P, V, C & A COMBO

F : M, P & S COMBO

G : M, P & D COMBO

L : M, P & C COMBO

B : M, P & V COMBO

S :ADJUSTABLE PRESSURE SWITCHES &


FAN CYCLING (LOW
AMBIENT)

D : PUMPDOWN
SOLENOID

C : COMPRESSOR
CIRCUIT BREAKER

V : UVM & VOLT FREE


CONTACTS

P : PRESSURE GAUGES

M: REPLACEABLE
CORE FILTER DRIER
& SHUT-OFF VALVE

J : 7.5HP ODP N : NO HEATER A : STD. OPTION+

12
BLOWER
MOTOR

A combination of volt free contact option: 1. Unit ON/OFF indication, 2. Compressor ON/OFF& trip indication, 3. Blower motor ON/OFF & trip indication.
Standard option contain sealed type filter drier & fixed low/high pressure switches and electronic thermostat.
Drip eliminators are recommended when velocity across the coil is above 500 FPM, high relative humidity and coastal areas.

Scroll compressors are available for models PMY240 - PMY600 only.


Single semi-hermetic compressors are available for models PMY240 & PMY300 only.

840

720

600

540

480

420

360

300

240

4, 5 & 6
NOMINAL
COOLING
CAPACITY
(MBH)

MODEL DECODING

B : BAG & PRE-FILTER


SECTION WITH 2"
THICK ALUMINUM
PRE-FILTERS & BAG
FILTERS

L : LOW VELOCITY FILTER SECTION WITH 2"


THICK ALUMINUM FILTERS

M : STD. FILTER RACK


WITH 2" THICK ALUMINUM FILTER

N : STD. FILTER RACK


WITH 2" THICK FIBER
GLASS FILTER

15
UNIT ACCESSORIES

STANDARD SPECIFICATIONS
A. GENERAL
The modular packaged unit is a factory assembled cooling or combination heating and cooling single zone unit suitable
for mounting on the roof or ground. The packaged unit consists of scroll or semi-hermetic compressors, cooling coil,
condenser coil, fans, electric heater (optional), control wiring and interconnecting piping all factory assembled. Unit
casing is of rigid construction mounted on pressed steel rail base with lifting holes for overhead rigging. The unit is
provided with an integral weather resistant control panel, ready for field connection to utilities and ducts.
These units are rated and tested in accordance with ARI Standard 360.
These units can be supplied with top and front supply air. Also they can provided top and side return air arrangements to
provide optimum installation flexibility. For various combinations of supply, return and fresh air please refer to details
inside this catalog.
These units can be provided with additional modules & accessories such as bag filters, low velocity filters, drip eliminator,
manual fresh air damper with rain hood, etc...

B. UNIT ENCLOSURE
Unit sections are of modular construction with base frame and panels of heavy gauge galvanized steel. Top & bottom
base pan, vertical posts, cross channels & supporting brackets joined together bolted. Steel sheet panels are zinc-coated
and galvanized by the hot dip process of lock-forming quality conforming to ASTM A 653 commercial weight G-90,
followed by baked on electrostatic polyester dry powder coat.

C. COMPRESSOR
Dual scroll compressors are used as standard for models PMY240 - PMY600 and dual semi-hermetic reciprocating compressors are standard for models PMY720 & above. As an option, single semi-hermetic reciprocating compressors may be
provided for models PMY240 - PMY300 and dual semi-hermetic reciprocating compressors for all other models. All compressors are conforming to ARI 540. The compressors are equipped with internal motor protection; factory installed crankcase heater and rubber vibration isolators for quiet and efficient operation. As an option, semi-hermetic compressor can
be fixed on anti vibration mounting (spring type) along with suction & discharge line vibration eliminators. Oil pressure
control is provided on units with semi-hermetic compressor only. Each compressor has lock-out devices to protect it from
short cycling when tripped by safety controls. The compressor motors conform to NEMA MG-1 & MG-2.

D. INSULATION
The air handling section is insulated with 1 inch thick 3 pounds per cubic foot density fiberglass insulation which will
prevent condensation from forming on the casing. Insulation meets the requirements of NFPA 90A and is protected
against deterioration and erosion from air currents.

E. EVAPORATOR/CONDENSER COILS
Coils are of the corrugated fin-and-tube type, constructed of seamless inner grooved copper tubes (3/8" dia.) and mechanically bonded to enhanced louvered aluminum fins for maximum heat transfer efficiency. As an option, corrugated
copper fins or enhanced coated aluminum fins may be provided. The fins have full self spacing collars, which completely
cover each tube. The staggered tube design improves the thermal efficiency. End plates and tube support sheets are 18
gauge galvanized steel, formed to provide structural strength. Each evaporator & condenser coil is pressure tested in the
factory at 300 psi & 450 psi air pressure respectively. Coils conform to ARI 410.
DRIP ELIMINATOR (OPTIONAL): If velocity across the coil is above 500 FPM, eliminator is recommended. Eliminators
are made of plastic material. Eliminator section is placed between coil & blower section. This arrangement eliminates
water carry over.

F. AIR COOLED CONDENSING SECTIONS


1. Fans are propeller type, direct drive, upward discharge through stamped form venturi, provided with protective grilles
mounted on top panel within the unit casing.
2. Motors are totally enclosed air-over type (TEAO) with class "F" insulation. Inherent thermal protection is the automatic
reset type. Motors are firmly fixed in motor mount.
3. Each compressor has separate condenser coil with safety controls. Sight glass and filter drier (sealed type) are
standard on all models.
3

G. EVAPORATOR SECTION
DRAIN PAN:
Drain pan is provided under the cooling coil and shall incorporate coupling connection on both ends. The drain pan is
made of G-90 galvanized steel with mastic coated liner for additional corrosion protection.
EVAPORATOR FANS:
Fans are of centrifugal type with forward curved blades capable of handling total required airflow & static pressure in the
published ranges. The choices of fan section configurations are top and front supply air arrangements to provide optimum installation flexibility. Casing and impeller is made of galvanized steel. Fan drive is through adjustable pitch pulleys
and V-belt drive. Blower motor is mounted on anti-vibration pads on adjustable base and secured by locking device.
Alignment and tensioning can be done in the field without moving the motor from the base frame. Blower housing and
motor are mounted on vibration pads. Fan wheels, shaft and bearings are selected to operate at 25% below first critical
speed. Pillow block bearings are selected for at least 200,000 hours average life at design operating conditions. Shaft is
turned, ground and polished from solid steel. Fans and pulleys are keyed to shafts and design for continuous operation
at maximum motor horse power and fan speed. All rotating components & assemblies are statically and dynamically
balanced and every unit is vibration tested before shipment from the factory.
Motors are of the open drip proof type to NEMA design class B insulation, 400C ambient temperature and across-the-line start
as standard. Totally enclosed fan cooled motors are available as an option, as are class F insulation, 650C ambient rating.

H. MIXING BOX
The standard mixing box has top and side return air arrangement with fresh air opening is always from the side of the unit.
Two inch thick filter racks are provided as standard on all models. Additional accessories such as return and fresh air
dampers (oppose blade) and rain hood can be provided.

I. FILTERS
Filters can be easily accessible through the filter access panel. The unit shall have provision to mount 2" thick high
velocity filters. Fiber glass filters are standard for all models. As an option, aluminum filters can be provided. Optional
modules such as low velocity 2" thick aluminum filters arranged in a V-bank to increase the filtration. Also pre-filters plus
bag filters can also be provided to enhance air filtration.

J. CONTROL PANEL
The control panel design is equivalent to NEMA 4 with hinged door for easy access ensuring dust and weather proof
construction. Internal power and control wiring is neatly routed, properly anchored and all wires identified with cable
markers as per NEC standard applicable to HVAC units.

K. MICROPROCESSOR CONTROLLER
These condensing units are provided with a microprocessor control board incorporating the following features:
- BALANCE LOADING OF COMPRESSORS: The units electronic control automatically operates lead / lag sequence
of compressors. This is to load the compressors evenly over long periods of operation. If required however, compressor-1 can also be set to always lead. In this case, compressor-1 always starts first and stops last. (Selectable through
dip switch setting on control board).
- PUMP DOWN FUNCTION: In units equipped with pump down system, the controller provides the time delay between
solenoids opening and compressor starting to equalize the pressure in the system necessary for compressor to startup. (Selectable through dip switch setting on control board).
- COMPRESSOR ANTI-RECYCLING PROTECTION: The controller has a built-in 3 minutes minimum off timer for
compressor. This is for compressor protection in case of accidental manual re-set or immediate re-cycling of thermostat due to load demand.
- COMPRESSOR LOCK-OUT FUNCTION: If any of the units safety control trips due to abnormal conditions, the electronic controls locks out the compressor after a pre-determined timing preventing a re-start unless attended by a qualified service technician. The unit can be re-started through thermostat re-set after ensuring safe system conditions.
- FAULT DIAGNOSTICS: In case of system fault, LEDs on the board emits a flashing signal indicating where the fault
is. This is to guide the service technician in identifying the fault.
- DIGITAL I/Os: The units control board is compatible to operate with a DDC controller or any standard 24VAC thermostat.
- SEQUENTIAL CONTROL: With input signals from the thermostat, the motors in the equipment is started in sequential order: supply fan condenser fan compressor; at a pre-determined timings.
4

OPTIONAL ITEMS
A. FAN CYCLING (HEAD PRESSURE CONTROL)
The capacity of air cooled condensers vary with the difference between condensing temperature and condenser entering
air temperature (ambient temperature). It increases as this difference increases. For a given capacity, a drop in the
ambient temperature will lower the condensing temperatures and if the ambient temperature drops below a given limit,
head pressure control is required.

B. PUMP DOWN SOLENOID VALVE


A pump down solenoid valve may be installed in the liquid line. When the room thermostat is satisfied, the valve closes
and the compressor continues to run until a substantial portion of the refrigerant has been pumped out from the evaporator. The low pressure switch will cycle off the compressor at a predetermined evaporator pressure.

C. VOLTAGE MONITOR
This device protects the motors in the unit from faults such as; under or over voltage, unbalance, phase loss & phase reversal
of the power supply. When the device sensed such faults, it will cut-off the supply in the control circuit thereby cutting off power
to the motors. The voltage monitor will re-set automatically when power is brought back to its normal conditions.
LINE VOLTAGE
RANGE
190 - 480 VAC

TRIP & RE-SET VOLTAGE (% OF SET POINT)


UNDER VOLTAGE

OVER VOLTAGE

PHASE IMBALANCE

TRIP

RE-SET

TRIP

RE-SET

TRIP

RE-SET

90%

93%

110%

107%

6%

4.5%

D. ADJUSTABLE HIGH PRESSURE SWITCH (HPS)


The standard HPS is permanently set to open at 450 psig. Depending on customer specifications, an adjustable high
pressure switch may be provided. Typical pressure settings are shown in table below. The settings may be field adjusted
to suit applications on adjustable type.
OPEN

CLOSE

450 10 Psig

360 15 Psig

E. ADJUSTABLE LOW PRESSURE SWITCH (LPS)


The standard LPS is permanently set to open at 25 psig. Depending on customer specifications, an adjustable low
pressure switch may be provided. Typical pressure settings are shown in table below. The settings may be field adjusted
to suit applications on adjustable type.
OPEN

CLOSE

25 5 Psig

50 5 Psig

F. MECHANICAL OPTION
1. Capacity control: On semi-hermetic compressor, capacity control is achieved by cylinder unloading.
2. Suction & discharge rotor lock valve for scroll compressors.
3. Replaceable core filter drier with liquid line shut of valves.
4. Suction, discharge and oil (semi hermetic compressor only) pressure gauge.
5. Condenser pressure relief valves.
6. Discharge line mufflers.
7. Heresite coated condenser (specify your requirements during order entry).
8. Condenser coil guard.
9. Duct sensors.

G. ELECTRIC HEATERS
Electric heaters are of the resistance open coil type and conform to the requirements of UL 573 or equivalent. Electrical
characteristics, kW capacities and number of stages are as indicated. Thermal cut-outs, fusible links and airflow switches
are provided to shut-off power to heaters in case of airflow failure.
5

H. ELECTRONIC THERMOSTAT
General information: Electronic thermostat shall control one or two stage heating and cooling applications. The thermostat normally displays room temperature and mode of operation.
The temperature can be set by up/down buttons for both cooling and heating cycles. The thermostat also allows you to
select continuous fan operation, or have the fan on intermittent operation with the equipment.
The thermostat is best located about 1500 mm (5 Ft.) above floor level, on a partition wall (not an outside wall), and
should not be exposed to direct light from lamps, sun etc. It should be in return air stream, away from supply air registers/
diffusers.

Single/dual stage - Cooling & heating.


Low voltage control - 24 VAC (nominal).
Room temperature display - in C or F.
Mode of operation - OFF/COOL/HEAT/AUTO.
Fan mode - ON: Continuous fan operation; AUTO: Fan operates ON/OFF with compressor.
Heating & cooling setpoint is permissible.
Temperature set button - Up for increasing & down for decreasing temperature.
Built-in compressor fault & clogged filter indication led lights.
Remote/duct sensor (optional).
0

TYPICAL THERMOSTAT
Part No.

Heating Cooling Selector Switch Positions


Stages Stages Mode Switch Fan Switch

800-646-91

OFF-HEAT/COOL

ON - AUTO

800-646-92*

OFF-HEAT/COOL

ON - AUTO

* with built-in compressor fault & clogged filter indication led lights.

TYPICAL THERMOSTAT

STANDARD FEATURES/OPTIONS
DESCRIPTION

STANDARD FEATURES

Scroll compressor (for PMY240 - 600)


Semi-hermetic compressor (for PMY240 - 600)
Semi-hermetic compressor (for PMY720 & above)
Anti vibration mounting (spring type)
Capacity control for semi-hermetic compressor
Compressor crankcase heaters
Compressor circuit breakers
Compressor overload protection
Vibration eliminator piping side (semi-hermetic compressor)
Compressor shut-off valves (scroll)
Voltage monitor
Evaporator fan - belt driven, centrifugal type
Evaporator fan motor -ODP type
Evaporator fan motor -TEFC type
Condenser fan motor, totally enclosed air-over type
Condenser fan - direct drive, propeller type
Electric heaters
Filter drier (sealed type)
Filter drier (replaceable type)/ core & liquid line isolating Valve
Discharge muffler
Sight glass (moisture indication)
Drain connection, both sides
Filter (2" thick) fiber glass
Filter (2" thick) aluminum
Bag filter
Low pressure switch (fixed type)
High pressure switch (fixed type)
Anti-ice
Fan cycling (low ambient)
Pump down solenoid valve
Pressure relief valve
Thermostatic expansion valve
Thermostat
Coil guard
Condenser fan guard
Manual outside air damper with hood & pre filters
High/low/oil pressure gauges
Volt free contact
Drip eliminator

OPTION
(FACTORY INSTALLED)

PHYSICAL DATA
MODEL NUMBER

PMY240

NOMINAL CAPACITY , TONS*

20

NUMBER OF REFRIGERATION CIRCUIT


COMPRESSOR

Standard

PMY300 PMY360 PMY420 PMY480 PMY540 PMY600 PMY720 PMY840


25

Single (S.H.) Single (S.H.)


Dual (Scroll) Dual (Scroll)

Scroll

Scroll

30

35

40

45

50

60

70

Dual

Dual

Dual

Dual

Dual

Dual

Dual

Scroll

Scroll

Scroll

Scroll

Scroll

Semi-hermetic

Type
Optional

Semi-hermetic

Scroll

110

110

140

140 & 158

158

158 & 200

200

Semi-hermetic

140

158

106

106

140

158

158

167

167

Oil per system, oz

Refrigerant
Charge
per system
(oz)**
CONDENSER FAN

R22
Scroll

360

450

600

690/600

720

900/720

900

Semi-hermetic

360

450

600

650

720

810

900

1080

1260

Type
Qty. Diameter (inch)

2 30

2 30

3 30

3 30

4 30

4 30

4 30

5 30

6 30

Nominal CFM

15200

15000/15200

22800

22600/22800

30400

30300/30400

30200

38000

45600

Motor HP RPM
CONDENSER COIL

Propeller

1.51100 1.51100 1.51100 1.51100 1.51100 1.51100 1.51100 1.51100 1.51100

Type

Inner grooved tubes and enhanced fins

3/8514
3/8514
Tube DiaRowsFins per inch
3/8414 3/8514 3/8414
3/8414
3/8514
3/8414
3/8414
(Scroll compressor)
Tube DiaRowsFins per inch 3/8414 3/8414 3/8314 3/8414 3/8414 3/8414 3/8514 3/8414 3/8514
(Semi-hermetic compressor)
Total face area (Sq. ft.)

28

28

46.66

EVAPORATOR BLOWER Type


Size (inch) & Qty.

56

56

70

70

18x18(1) 18x18(1) 20x18(1) 20x18(1) 18x18(2) 18x18(2) 18x18(2) 20x18(2) 20x18(2)

Nominal CFM

7500

9000

10500

12000

Motor HP Std./Alt.

7.5/10

7.5/10

7.5/10/15

10/15

213-T/215-T

213-T/215-T
254-T

Fan RPM range

56

Centrifugal & V-belt drive

Motor frame (NEMA) Std./Alt. 213-T/215-T

EVAPORATOR COIL

46.66

215-T/254-T

14000

15000

16300

19500

10/15/20 15/20/25 15/20/25 15/20/25


215-T/254-T
256-T

215-T/254-T
256-T

254-T/256-T
284-T

254-T/256-T
284-T

22000
20/25
256-T/284-T

615-1115 615-1115 585-1010 585-1010 700-1350 700-1350 700-1350 700-1200 700-1200

Type

Inner grooved tubes and enhanced fins

Tube DiaRowsFins per inch 3/8314 3/8414 3/8414 3/8514 3/8514 3/8514 3/8514 3/8514 3/8514
Total face area (Sq. ft.)
HIGH PRESSURE SWITCH

LOW PRESSURE SWITCH

22

24

24

31.11

31.11

31.11

40

40

Open (PSIG)

450 10

450 10 450 10 450 10 450 10 450 10 450 10 450 10 450 10

Close (PSIG)

360 15

360 15 360 15 360 15 360 15 360 15 360 15 360 15 360 15

Open (PSIG)

25 5

25 5

25 5

25 5

25 5

25 5

25 5

25 5

25 5

Close (PSIG)

50 5

50 5

50 5

50 5

50 5

50 5

50 5

50 5

50 5

84

84

84

84.5

85

85.5

85.5

86

86.5

1350

1400

1800

1850

2300

2450

2600

3050

3300

SOUND PRESSURE LEVEL, dBA (@ 1meter)**


SHIPPING WEIGHT, Kg.

NOTE: *
**

22

Nominal cooling capacity @ 800F DB/670F WB indoor and 950F DB outdoor (ambient) temperature.
Based on free field area at ARI conditions. Tolerance: 2dBA.

SELECTION PROCEDURE
1. Determine cooling and heating capacity requirements at design conditions
Data:
Condenser entering air temperature
Evaporator entering air temperature
Evaporator airflow
Required cooling capacity
Sensible heat capacity
Required heating capacity
External static pressure
Power supply (V-Ph-Hz)
Unit type
Compressor type

: 1150F
: 800F DB / 670F WB
: 14,000 CFM
: 420,000 BTUH
: 300,000 BTUH
: 40 kW
: 1.6 INCH WG.
: 460-3-60
: Front fan supply (top return air)
: Scroll

2. Unit selection based on required cooling capacity


Enter cooling capacity performance data at condenser entering air temp. at 1150F and evaporator entering air temp.
800F DB, 670F WB, 14000 CFM airflow. The PMY480 unit will give 460,100 BTUH cooling capacity (gross) and 342,700
BTUH sensible heat capacity (gross).

3. Electric heater selection


Heating capacity required = 40 kW.
Enter electric heating table for PMY480 at 460-3-60 power supply.
40 kW heater at 460 volts satisfies the required heating.

4. Determine fan speed and power requirements at design conditions


Before entering the fan performance tables, calculate the summation of external static pressure for the required components as follows.
External static pressure
: 1.6 INCH WG.
Additional module
: NIL
1.6 INCH WG.
Enter fan performance table for PMY480 model. For 14000 CFM and external static pressure of 1.6 INCH WG, it require
1006 RPM and 12.25 brake horse power (BHP) wherein the standard motor will meet job requirements.

5. Determine input power to motor


Use fan motor efficiency table.
BHP x 746 watts
Blower motor watts =
=
Motor efficiency

12.25 x 746
0.91

= 10,042 watts.

6. Determine net capacities


Above capacities are gross and do not include blower motor heat gain.
Determine net capacities as follows:
Net cooling capacity
= Gross cooling capacity blower motor heat
= 460,100 (10,042 WATTS x 3.413 BTUH/WATTS) = 425,827 BTUH
Net sensible capacity = 342,700 (10,042 WATTS x 3.413 BTUH/WATTS) = 308,427 BTUH

7. To calculate leaving air conditions (see footnote for capacity tables)


DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM)
WBL = DBL [DR (DBE WBE)]
When sensible capacity approaches 1.0, especially at entering
DB higher than 800F, find DBL in the same manner above, but
WBL is to be found from intersection of DBL Line on a psychrometric chart with the horizontal line of humidity ratio(W) where
(at SHR = 1), WL = WE.

8. Altitude correction factors for cooling capacity


ALTITUDE, FT.
FACTOR

2000

4000

6000

8000 10000

Total capacity

0.98

0.96

0.93

0.90

0.88

Sensible capacity

0.93

0.86

0.80

0.75

0.70

WBE
WBE

WBL

WBL

WE
WE= WL
DBL

DBE
SHR=1.0

DBL

DBE
SHR<1.0

COOLING CAPACITIES
(Dual scroll compressor units)
Model No.: PMY 240
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

5600/0.112
62
219.1
183.0
23.6
211.3
178.8
25.7
202.8
174.4
27.7
194.7
171.5
29.7
186.2
168.3
31.8

67
237.7
154.3
24.5
228.9
150.1
26.6
220.0
146.1
28.7
211.2
143.1
30.7
202.2
140.1
32.7

72
256.8
124.9
25.2
247.4
121.0
27.3
237.8
117.1
29.4
228.6
114.2
31.4
218.7
111.1
33.4

EVAPORATOR AIRFLOW, CFM/DR


7500/0.131
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
233.3
252.6
272.8
214.5
177.5
139.9
25.0
25.8
26.4
224.5
243.2
262.5
210.0
173.3
135.8
27.1
27.9
28.5
215.4
233.5
252.2
205.6
169.1
131.9
29.1
29.9
30.5
206.5
224.0
242.5
201.8
166.1
129.2
31.1
31.9
32.5
197.7
214.3
232.1
193.9
163.1
126.2
33.1
33.9
34.6

8400/0.143
62
238.3
228.6
26.2
228.8
223.3
28.3
219.6
213.7
30.2
210.8
206.0
32.2
201.3
197.4
34.2

67
257.8
187.7
26.9
248.0
183.4
29.0
237.8
179.0
30.9
228.3
176.2
32.9
218.5
173.3
34.9

72
278.4
146.5
27.5
267.9
142.4
29.6
257.1
138.4
31.6
247.3
135.7
33.6
236.4
132.6
35.6

Model No.: PMY 300


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

7200/0.061
62
272.9
236.5
26.5
266.4
231.5
28.9
250.7
226.1
31.2
239.7
221.6
33.6
229.0
217.4
35.9

67
295.0
197.5
27.2
288.4
193.2
29.6
271.6
187.7
32.0
260.0
183.4
34.4
248.5
179.2
36.7

72
317.2
157.5
27.9
310.7
153.8
30.4
293.0
148.4
32.8
280.9
144.3
35.3
268.8
140.4
37.7

EVAPORATOR AIRFLOW, CFM/DR


9000/0.078
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
284.3
306.7
329.7
268.0
220.3
172.0
28.4
29.1
29.9
277.3
300.0
323.2
262.7
216.0
168.2
30.8
31.5
32.3
260.8
282.5
304.9
251.8
210.6
163.1
33.1
33.9
34.8
249.4
270.4
292.1
241.1
206.4
159.0
35.5
36.3
37.3
238.0
258.3
279.7
230.6
202.2
155.2
37.7
38.6
39.6

10800/0.096
62
292.2
282.8
30.3
285.2
273.6
32.6
267.8
258.5
35.0
256.0
247.4
37.3
244.2
236.6
39.6

67
315.1
242.0
31.0
308.1
237.4
33.4
289.8
232.1
35.8
277.7
228.1
38.2
265.5
224.2
40.4

72
338.4
185.5
31.9
331.9
181.8
34.3
312.8
176.6
36.8
299.8
172.6
39.3
287.2
168.9
41.6

Model No.: PMY 360


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

8400/0.066
62
333.4
281.7
33.9
320.6
275.1
37.3
307.5
270.2
40.6
294.6
265.3
44.0
280.4
259.3
47.3

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
361.3
236.5
34.8
347.4
230.2
38.2
333.6
225.5
41.6
320.1
220.9
45.0
304.4
214.8
48.4

72
390.7
190.7
35.5
376.2
184.9
38.9
361.0
180.0
42.4
346.5
175.4
45.9
330.2
169.7
49.4

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


10500/0.084
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
348.2
377.8
408.7
318.1
263.7
208.1
36.2
37.0
37.7
334.4
362.8
392.8
311.4
257.1
202.1
39.6
40.4
41.1
320.7
348.2
377.0
306.7
252.5
197.3
42.9
43.8
44.6
307.0
333.7
361.6
297.9
247.7
192.7
46.2
47.2
48.1
291.9
317.3
344.4
283.4
241.7
187.1
49.5
50.6
51.6
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

12600/0.104
62
359.1
346.9
38.0
344.2
331.7
41.4
330.0
319.1
44.7
315.7
306.3
48.0
300.3
291.6
51.3

67
389.5
289.0
38.8
373.6
282.2
42.1
358.3
277.6
45.5
343.6
273.2
48.9
326.7
267.2
52.3

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.45 ESP for PMY240/PMY300 and 0.55 ESP for PMY360.

10

72
421.5
224.2
39.5
405.2
218.2
42.9
388.9
213.7
46.4
372.6
208.9
49.9
354.7
203.2
53.4

COOLING CAPACITIES
(Dual scroll compressor units)
Model No.: PMY 420
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

9600/0.040
62
390.7
333.0
40.2
375.2
326.0
43.5
358.5
317.8
46.8
341.3
309.5
50.4
324.2
303.8
54.0

67
421.6
279.5
41.3
405.4
272.9
44.6
387.5
265.0
47.9
369.2
257.1
51.7
350.8
251.3
55.4

72
454.8
225.3
42.2
437.4
218.9
45.6
418.3
211.5
49.0
398.9
204.0
52.8
379.5
198.3
56.6

EVAPORATOR AIRFLOW, CFM/DR


12000/0.051
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
408.4
441.2
476.4
376.0
311.4
246.0
42.9
43.9
44.8
391.6
423.5
457.8
368.8
304.5
239.5
46.2
47.2
48.2
374.4
404.7
438.1
360.9
296.7
232.3
49.4
50.5
51.5
356.1
385.5
417.4
349.0
288.7
224.6
53.0
54.2
55.3
338.3
366.2
397.2
333.7
283.1
219.1
56.7
57.9
59.2

14400/0.065
62
421.0
413.9
45.2
403.5
396.9
48.5
385.3
378.3
51.7
366.4
359.2
55.3
347.6
342.9
58.9

67
455.1
341.4
46.2
436.4
334.3
49.4
417.0
326.4
52.7
397.0
318.3
56.4
377.1
312.9
60.1

72
492.2
265.3
47.1
473.0
258.9
50.5
451.9
251.2
53.9
430.8
243.7
57.7
409.7
238.3
61.5

Model No.: PMY 480


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

11000/0.034
62
452.9
383.7
46.2
436.6
376.7
50.4
419.4
368.2
54.5
402.1
361.5
58.6
384.9
354.1
62.7

67
490.7
323.0
47.6
473.5
316.2
51.8
454.9
308.0
56.0
436.8
301.6
60.1
418.2
294.3
64.3

72
531.0
261.3
48.8
513.0
254.9
53.1
493.6
247.3
57.4
474.1
240.9
61.6
454.2
233.8
65.9

EVAPORATOR AIRFLOW, CFM/DR


14000/0.046
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
477.0
517.7
561.2
439.1
364.3
288.5
48.9
50.1
51.3
459.4
498.9
541.3
431.9
357.3
281.7
53.0
54.3
55.7
441.1
479.5
520.8
423.4
349.2
274.2
57.1
58.5
60.0
422.8
460.1
500.3
414.8
342.7
267.9
61.1
62.5
64.2
404.4
440.0
479.1
397.2
335.2
260.8
65.2
66.7
68.5

16700/0.057
62
491.9
481.1
52.1
473.0
463.2
56.3
454.1
444.1
60.3
435.9
427.7
64.3
416.2
408.7
68.4

67
534.3
398.7
53.3
514.8
391.8
57.5
494.5
383.6
61.7
474.2
377.0
65.8
453.9
369.8
70.0

72
580.2
310.8
54.7
559.3
304.0
59.0
537.7
296.2
63.4
516.8
290.2
67.6
495.2
283.3
71.9

Model No.: PMY 540


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

12500/0.040
62
505.5
443.5
49.3
486.4
422.2
52.7
466.2
412.7
57.2
445.5
404.4
59.8
424.3
395.4
65.3

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
547.3
372.8
50.8
527.3
353.9
54.2
505.6
344.7
58.7
483.9
336.9
61.3
460.6
327.8
67.0

72
592.1
301.2
52.1
570.6
284.5
55.5
548.0
276.0
60.2
524.3
268.0
62.9
499.5
259.3
68.7

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


15000/0.049
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
524.8
569.0
616.2
490.1
407.5
323.8
52.3
53.7
55.1
504.6
547.5
593.5
467.2
387.4
306.5
55.7
57.0
58.5
483.7
524.8
569.6
457.9
378.1
297.8
60.1
61.6
63.1
462.1
502.0
545.0
449.8
370.3
290.0
62.7
64.2
65.8
439.2
478.0
519.2
432.0
361.3
281.3
68.2
69.9
71.7
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

18000/0.060
62
541.2
530.4
56.0
520.0
509.9
59.3
498.0
488.1
63.7
476.1
467.9
66.3
452.6
445.1
71.8

67
587.6
446.4
57.3
565.0
424.9
60.6
541.6
415.8
65.2
518.2
408.2
67.8
493.2
399.2
73.5

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.65 ESP for PMY420 and 0.75 ESP for PMY480/PMY540 .

11

72
637.0
348.7
58.8
613.7
330.9
62.2
588.9
322.3
66.8
563.3
314.4
69.5
536.1
305.5
75.4

COOLING CAPACITIES
(Dual scroll compressor units)
Model No.: PMY 600
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

14000/0.044
62
557.6
484.2
53.5
538.0
454.0
58.2
517.9
468.6
62.7
497.2
459.7
67.2
475.2
449.3
71.6

67
603.9
406.8
55.1
583.3
380.5
59.8
561.4
391.3
64.4
539.0
382.4
69.0
515.3
372.3
73.5

72
652.9
328.0
56.6
631.2
305.7
61.3
608.3
313.1
66.0
584.1
304.5
70.7
558.8
294.8
75.3

EVAPORATOR AIRFLOW, CFM/DR


16300/0.054
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
574.6
622.6
673.8
525.5
437.3
347.9
56.5
58.0
59.5
554.0
600.7
651.3
493.3
409.3
324.7
61.2
62.7
64.2
532.7
578.0
626.7
509.6
421.7
332.7
65.7
67.3
68.9
511.4
554.7
602.1
500.9
412.8
324.4
70.1
71.8
73.7
488.6
530.7
576.1
478.9
403.0
314.8
74.5
76.3
78.3

19500/0.068
62
592.2
580.0
60.8
571.0
543.7
65.4
548.9
537.9
69.9
526.0
515.4
74.3
503.0
493.0
78.7

67
641.6
477.0
62.3
619.7
447.9
66.9
596.0
462.1
71.5
571.5
453.1
76.0
547.0
443.5
80.5

72
695.1
373.3
63.9
671.6
348.9
68.5
647.2
358.9
73.3
621.1
350.3
78.0
594.3
340.7
82.6

Single semi-hermetic compressor units


Model No.: PMY 240
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

5600/0.112
62
217.7
181.8
21.7
209.6
178.3
23.3
201.6
175.0
24.9
192.5
170.0
26.5
183.7
166.6
28.3

67
236.2
153.2
22.7
227.7
150.0
24.4
219.0
146.6
26.1
209.3
141.9
27.8
199.8
138.6
29.7

72
256.1
124.3
23.6
246.7
120.9
25.4
237.5
117.8
27.2
227.4
113.5
29.1
217.0
110.1
31.1

EVAPORATOR AIRFLOW, CFM/DR


7500/0.131
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
230.7
250.7
272.2
212.7
176.3
139.3
23.3
24.2
25.1
221.9
241.3
262.2
209.3
172.9
136.1
24.9
25.9
26.9
213.1
231.5
251.8
206.0
169.3
132.7
26.4
27.6
28.8
203.3
221.4
240.8
198.0
164.7
128.2
28.1
29.4
30.7
194.1
211.3
229.9
189.6
161.4
124.9
29.9
31.3
32.7

8400/0.143
62
235.4
226.6
24.4
226.2
221.2
26.0
216.7
212.2
27.6
207.2
201.8
29.3
197.3
192.7
31.1

67
255.6
186.4
25.3
245.8
182.9
27.0
236.0
179.5
28.8
225.4
174.6
30.6
215.2
171.4
32.5

72
277.7
145.8
26.2
267.2
142.5
28.1
256.7
139.1
30.0
245.5
134.6
31.9
234.3
131.3
34.0

Model No.: PMY 300


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

7200/0.061
62
271.4
236.5
25.1
264.5
235.2
27.0
249.1
225.7
28.9
237.8
221.2
30.8
225.9
216.0
32.8

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
295.3
198.2
26.1
288.1
196.8
28.1
271.6
187.9
30.2
259.4
183.5
32.2
246.3
178.3
34.4

72
321.2
159.4
27.2
313.8
157.9
29.3
296.1
149.7
31.6
282.7
145.2
33.8
268.8
140.3
36.1

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


9000/0.078
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
282.4
307.9
335.6
267.9
221.5
174.5
27.2
28.2
29.3
274.9
300.0
327.4
266.8
220.2
173.0
29.0
30.2
31.5
258.4
282.5
308.8
249.8
210.9
164.6
30.9
32.3
33.8
246.7
269.6
294.8
238.9
206.4
160.2
32.9
34.3
36.1
234.1
256.3
280.1
226.7
201.5
155.2
34.9
36.5
38.5
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

10800/0.096
62
290.4
281.8
29.1
282.4
276.2
31.0
265.4
256.5
33.0
253.2
245.2
34.9
240.5
232.8
37.0

67
316.5
243.2
30.2
308.6
242.2
32.2
290.3
232.6
34.3
277.2
228.3
36.4
263.1
223.2
38.7

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.75 ESP for PMY600 and 0.45 ESP for PMY240/PMY300 .

12

72
345.9
188.5
31.3
337.5
187.2
33.6
318.0
178.5
36.0
303.5
174.1
38.3
288.6
169.3
40.7

COOLING CAPACITIES
(Dual semi-hermetic compressor units)
Model No.: PMY 360
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

8400/0.066
62
327.2
278.6
31.9
317.0
276.8
34.4
300.9
267.8
37.1
287.0
260.9
39.9
272.3
254.9
42.9

67
356.5
234.5
33.2
346.0
232.6
36.0
328.5
223.9
38.9
313.2
217.1
41.9
297.5
211.4
45.2

72
387.8
189.4
34.4
376.9
187.4
37.6
358.1
179.3
40.8
341.8
172.9
44.0
324.8
167.2
47.5

EVAPORATOR AIRFLOW, CFM/DR


10500/0.084
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
340.9
371.5
405.5
314.8
260.9
206.9
34.4
35.6
36.8
329.9
360.5
393.8
313.4
259.5
205.0
36.9
38.5
40.2
312.9
341.9
373.8
303.2
250.5
196.6
39.7
41.5
43.5
298.3
325.9
356.6
288.1
243.6
190.2
42.6
44.6
46.8
283.2
310.0
339.0
274.1
238.3
184.6
45.6
47.9
50.4

12600/0.104
62
350.3
338.2
36.3
338.8
330.5
39.0
321.2
311.2
41.8
306.4
295.9
44.7
290.4
281.1
47.7

67
382.9
286.4
37.6
370.9
284.8
40.6
351.8
275.7
43.6
335.4
268.9
46.7
318.5
263.3
50.1

72
418.2
223.0
38.8
405.7
221.1
42.3
385.1
212.7
45.7
367.7
206.4
49.1
349.2
200.8
52.6

Model No.: PMY 420


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

9600/0.040
62
387.4
331.2
39.7
372.3
324.7
42.6
355.6
316.5
45.5
338.8
309.3
48.7
320.8
300.4
52.0

67
421.2
279.1
41.1
405.0
272.7
44.3
387.1
264.8
47.5
369.6
258.1
50.9
350.0
249.5
54.5

72
457.2
226.1
42.4
440.7
220.2
45.9
422.1
212.9
49.6
402.6
206.0
53.2
381.5
197.8
57.0

EVAPORATOR AIRFLOW, CFM/DR


12000/0.051
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
405.2
441.2
480.0
374.5
311.2
247.1
42.6
43.9
45.1
388.5
423.5
461.9
367.5
304.5
241.0
45.5
47.1
48.8
370.7
404.7
442.2
359.2
296.7
233.7
48.5
50.5
52.7
353.5
386.0
421.6
347.6
289.9
226.8
51.7
54.0
56.4
334.6
365.7
399.3
328.1
281.3
218.4
55.1
57.6
60.3

14400/0.065
62
417.3
409.8
45.0
400.3
393.8
48.0
381.5
374.6
51.1
363.3
357.3
54.3
343.8
337.1
57.7

67
455.1
341.0
46.2
437.0
334.6
49.6
417.0
326.4
53.1
397.7
319.7
56.6
376.4
310.8
60.2

72
496.6
266.6
47.5
477.3
260.4
51.4
456.8
253.0
55.4
435.1
246.0
59.2
412.1
237.6
63.1

Model No.: PMY 480


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

11000/0.034
62
442.9
379.6
44.0
425.6
371.9
47.1
407.4
363.8
50.1
389.2
355.8
53.4
369.5
347.2
56.7

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
481.2
319.5
45.7
462.6
311.9
49.0
443.5
304.3
52.3
424.0
296.4
55.8
403.0
288.2
59.3

72
523.0
258.7
47.4
503.1
251.4
51.0
483.2
244.2
54.6
461.8
236.4
58.4
439.1
228.4
62.2

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


14000/0.046
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
465.5
506.8
552.2
434.5
360.4
285.7
46.8
48.5
50.3
446.5
486.8
531.0
426.4
352.7
278.4
50.0
51.9
54.0
427.0
466.1
509.3
418.4
345.0
271.0
53.1
55.3
57.8
407.5
444.9
486.4
399.8
336.7
263.1
56.4
58.9
61.7
387.4
423.0
462.2
380.4
328.8
255.0
59.7
62.4
65.6
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

16700/0.057
62
479.5
469.7
50.2
459.9
450.7
53.4
439.5
431.2
56.6
419.1
411.2
59.9
398.0
390.9
63.3

67
522.7
394.7
51.9
502.5
387.5
55.4
480.7
379.6
58.8
458.3
371.0
62.5
435.8
363.3
66.1

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.55 ESP for PMY360, 0.65 ESP for PMY420 and 0.75 ESP for PMY480.

13

72
570.8
308.1
53.9
548.5
300.6
57.7
525.5
293.1
61.5
501.7
285.1
65.5
477.3
277.3
69.5

COOLING CAPACITIES
(Dual semi-hermetic compressor units)
Model No.: PMY 540
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

12500/0.040
62
503.8
428.4
48.0
485.3
421.7
52.2
465.1
412.5
55.9
444.4
403.4
59.6
422.7
393.8
63.4

67
547.3
360.9
49.9
527.8
354.3
54.4
506.1
345.3
58.3
483.9
336.3
62.3
460.6
327.2
66.5

72
594.3
292.3
51.8
573.3
285.6
56.6
551.2
277.5
60.9
526.9
268.6
65.2
501.1
259.3
69.7

EVAPORATOR AIRFLOW, CFM/DR


15000/0.049
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
522.9
569.0
618.8
473.4
394.5
314.3
51.2
53.0
55.0
503.3
547.5
596.1
466.9
387.4
307.5
55.4
57.6
59.9
481.7
524.8
572.2
457.3
378.4
298.9
59.1
61.6
64.3
460.1
501.4
547.0
448.2
369.3
290.2
62.9
65.7
68.7
437.3
477.3
520.5
429.2
360.3
281.1
66.8
69.9
73.3

18000/0.060
62
539.6
524.7
55.0
518.4
508.5
59.3
495.7
486.3
63.0
473.7
464.8
66.8
450.2
441.9
70.8

67
587.6
432.0
56.8
565.0
425.0
61.5
541.6
416.2
65.5
517.4
407.2
69.7
491.6
397.6
73.9

72
640.1
338.6
58.9
616.8
332.0
63.9
592.0
323.6
68.4
565.6
314.7
72.9
537.7
305.4
77.6

Model No.: PMY 600


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

14000/0.044
62
554.5
474.6
60.8
535.6
465.0
65.3
510.6
454.6
69.9
487.4
446.0
74.9
463.6
436.6
79.8

67
602.1
399.2
63.3
582.1
390.1
68.3
555.4
380.0
73.3
529.9
371.0
78.6
504.4
361.8
84.0

72
652.9
322.6
65.7
631.8
314.0
71.2
603.5
304.3
76.8
576.3
295.5
82.6
548.5
286.2
88.4

EVAPORATOR AIRFLOW, CFM/DR


16300/0.054
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
571.7
621.1
674.5
515.4
429.4
342.3
64.0
66.5
68.9
551.9
599.9
652.0
505.6
420.0
333.5
68.6
71.5
74.5
525.6
571.7
622.5
495.2
409.7
323.8
73.3
76.7
80.3
501.4
546.2
594.4
486.6
401.4
315.1
78.3
82.1
86.2
476.6
519.4
565.6
469.9
391.9
305.8
83.3
87.5
92.1

19500/0.068
62
589.7
569.2
68.5
568.4
555.6
73.2
541.2
530.3
78.0
515.8
507.2
83.0
490.3
483.4
88.1

67
640.8
468.6
71.0
618.8
459.4
76.1
590.1
449.6
81.4
563.0
441.1
86.9
535.1
431.6
92.4

72
697.6
368.0
73.5
674.1
359.2
79.2
643.0
349.3
85.1
613.6
340.6
91.2
584.2
331.6
97.2

Model No.: PMY 720


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

16500/0.041
62
667.2
568.1
66.7
640.6
555.8
71.4
613.3
543.6
76.3
586.0
532.4
81.3
557.2
520.3
86.4

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
724.6
478.6
69.4
696.0
466.4
74.4
667.4
454.9
79.8
638.1
443.9
85.0
606.6
431.8
90.6

72
786.6
387.7
72.1
756.7
376.4
77.6
726.1
365.2
83.4
694.1
354.2
89.1
660.7
342.7
95.0

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


19500/0.050
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
689.9
749.9
815.3
622.0
518.3
413.8
70.0
72.7
75.5
661.1
720.3
784.2
608.8
506.4
402.5
74.7
77.8
81.1
632.2
689.8
751.4
596.3
494.6
391.0
79.7
83.2
87.0
604.1
658.6
718.6
585.5
483.1
380.3
84.7
88.6
92.8
574.4
626.4
683.3
565.2
471.4
368.5
89.9
94.1
98.9
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

23400/0.063
62
710.7
687.5
74.9
681.1
667.5
79.7
651.5
638.8
84.7
622.0
611.1
89.8
591.4
581.9
95.0

67
774.0
566.9
77.5
742.6
554.7
82.7
711.1
543.1
88.2
679.7
532.5
93.7
646.2
520.7
99.3

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.75 ESP.

14

72
844.2
445.8
80.5
810.9
434.2
86.2
776.6
422.6
92.2
742.3
411.8
98.2
706.0
400.2
104.3

COOLING CAPACITIES
(Dual semi-hermetic compressor units)
Model No.: PMY 840
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

20000/0.054
62
775.6
671.7
78.0
750.3
659.2
83.5
715.5
646.2
89.1
684.1
633.7
94.9
651.9
620.0
100.7

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
842.8
564.7
81.1
815.0
552.2
87.0
778.6
539.8
92.9
744.8
527.3
99.1
709.3
513.3
105.5

72
914.7
455.8
84.1
885.3
444.0
90.4
846.6
431.8
96.9
810.3
419.6
103.6
772.4
406.1
110.4

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


22000/0.060
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
789.9
858.4
932.2
706.7
590.3
472.3
80.4
83.5
86.5
763.1
829.8
901.8
693.3
577.6
460.4
86.0
89.4
92.8
728.5
792.6
862.9
681.6
565.5
448.7
91.6
95.4
99.4
696.0
758.2
825.0
668.7
553.3
436.0
97.4
101.6
106.2
662.4
722.0
786.1
654.4
539.3
422.5
103.3
108.0
113.1
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

24000/0.065
62
802.1
740.6
83.4
774.9
727.4
88.9
738.3
714.6
94.5
705.9
700.0
100.4
671.4
666.1
106.3

67
871.9
615.2
86.4
842.8
602.5
92.3
804.3
590.2
98.4
768.9
577.7
104.7
732.5
564.1
111.1

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.75 ESP.

15

72
947.6
488.5
89.5
916.6
476.5
95.8
876.2
464.5
102.4
837.9
452.1
109.3
798.6
438.8
116.3

16

253

418

506

187

342

414

208/230-3-60

380-3-60
(4 WIRE)

460-3-60

Fan Motor (Condenser)


Locked Rotor Amps
Rated Load Amps

Full Load Amps


Horse Power
Blower Motor

2.7

2.7

5.4

FLA

(2 EA for
PMY240/300 &
3 EA for 360)

FM
BM

239

19.2 125

23.5 145

42

12.4

9.7

7.5

10

15.6

12.5

7.5

10

25.4

19.4

10

7.5

124.7

MCA

150

MOCP

25.1/37.7
50.2

40*

12.6/18.8

10*/15*
20*/30*

50.2

12.6/18.8

10*/15*

40*

25.1/37.7

60.8

40*

20*/30*

30.4/45.6

20*/30*

15.2/22.8

10*/15*

60.8

15.2/22.8

10*/15*

40*

30.4/45.6

100.4

20*/30*

50.2/75.3

40*

25.1/37.7

10*/15*
20*/30*

100.4
150
150

78.3

61/62.6

61/61

61

74.9

58.3/59.3

58.3/58.3

58.3

95.5

73.9/76.5

73.9/73.9

73.9

91.6

70.8/72.6

70.8/70.8

70.8

157.3

80

80/80

80/80

80

80

70/70

70/70

70

100

90/90

90/90

90

100

90/90

90/90

90

175

130.7/130.7 150/150

130.7/130.7 150/150

130.7

149.8

50.2/75.3 124.7/124.7 150/150

25.1/37.7 124.7/124.7 150/150

40*

20*/30*

10*/15*

FLA

ELECTRIC
HEATER

PMY 240

RLA LRA HP FLA Nom. KW

COMPRESSOR
(2 EA)

Minimum Circuit Amps


Maximum Over Current Protection
*Combination of heater modules

FLA HP
BM
FM
LRA RLA MCA MOCP -

LEGEND:

Max.

VOLTAGE
RANGE

Min.

POWER
SUPPLY
(V-Ph-Hz)

DESCRIPTION

BM

19.6 125

24.4 145

47.1 245

10

7.5

10

7.5

10

7.5

12.4

9.7

15.6

12.5

25.4

19.4

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

50.2

25.1/37.7

12.6/18.8

50.2

25.1/37.7

12.6/18.8

60.8

30.4/45.6

15.2/22.8

60.8

30.4/45.6

15.2/22.8

100.4

50.2/75.3

25.1/37.7

100.4

50.2/75.3

25.1/37.7

FLA

ELECTRIC
HEATER

RLA LRA HP FLA Nom. KW

COMPRESSOR
(2 EA)

PMY 300

MODEL NUMBER

(Dual scroll compressor units)

ELECTRICAL DATA

78.3

61.9/62.6

61.9/61.9

61.9

74.9

59.2/59.2

59.2/59.2

59.2

95.5

75.9/76.5

75.9/75.9

75.9

91.6

72.8/72.8

72.8/72.8

72.8

157.3

142.2/142.2

142.2/142.2

142.2

149.8

136.2/136.2

136.2/136.2

136.2

MCA

80

80/80

80/80

80

80

70/70

70/70

70

100

100/100

100/100

100

100

90/90

90/90

90

175

175/175

175/175

175

175

175/175

175/175

175

MOCP

BM

239

27.8 187

39

56.8 425

15

10

7.5

15

10

7.5

15

10

7.5

19.4

12.4

9.7

24

15.6

12.5

38.8

25.4

19.4

50.2/75.3
100.4

20*/30*
40*

30.4/45.6
60.8

30.4/45.6
60.8

20*/30*
40*

20*/30*
40*

25.1/37.7
50.2

25.1/37.7
50.2

20*/30*
40*

20*/30*
40*

40*

20*/30*

50.2

25.1/37.7

60.8

30.4/45.6
40*

20*/30*

100.4

50.2/75.3
40*

20*/30*

100.4

40*

50.2/75.3

20*/30*

FLA

ELECTRIC
HEATER

RLA LRA HP FLA Nom. KW

COMPRESSOR
(2 EA)

PMY 360

90.1

90.1/90.1

90.1

83.1

83.1/83.1

83.1

80.4

80.4/80.4

80.4

119.9

119.9/119.9

119.9

111.5

111.5/111.5

111.5

108.4

108.4/108.4

108.4

182.8

182.8/182.8

182.8

169.4

169.4/169.4

169.4

163.4

163.4/163.4

163.4

MCA

110

110/110

110

110

110/110

110

100

100/100

100

150

150/150

150

150

150/150

150

125

125/125

125

225

225/225

225

225

225/225

225

200

200/200

200

MOCP

ELECTRICAL DATA
(Dual scroll compressor units)
MODEL NUMBER

DESCRIPTION

PMY 420

PMY 480

FM

VOLTAGE
RANGE

POWER SUPPLY
(V-Ph-Hz)

Min.

Max.

COMPR(3 EA for
ESSOR
PMY420 &
(2 EA)
4 EA for 480)
FLA

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

* *
40*

7.5 19.4 20 /30

208/230-3-60

187

253

5.4

81.4 505
&
&
56.8 425

* *
40*

10 25.4 20 /30

* *
40*

15 38.8 20 /30

* *
40*

7.5 12.5 20 /30

380-3-60
(4 WIRE)

342

418

2.7

42.1 280
&
&
39 239

* *
40*

10 15.6 20 /30

15

24

* *
40*

20 /30

9.7

414

506

2.7

33.6 225
&
&
27.8 187

100.4

194.2

250

* *
50*/60*

200.2

250

200.2

250

213.6

250

- Horse Power

BM

- Blower Motor

FM

- Fan Motor (Condenser)

LRA

- Locked Rotor Amps

RLA

- Rated Load Amps

38.8

100.4

213.6

250

112.2

150

20

50

30 /40

60.8

112.2

150

* *
50*/60*

115.3

150

10

30.4/45.6 112.2/112.2 150/150

15.6 30 /40

60.8

115.3

150

* *
50*/60*

123.7

150

30.4/45.6 115.3/115.3 150/150

42.1 280

30.4/45.6 123.7/123.7 150/150

25.1/37.7

87.6/87.6

110/110

50.2

87.6

110

90.3

110

25.1/37.7

90.3/90.3

110/110

50.2

90.3

110

97.3

125

25.1/37.7

97.3/97.3

125/125

50.2

97.3

125

MCA - Minimum Circuit Amps


MOCP - Maximum Over Current Protection

*Combination of heater

15

30 /40

* *
50*/60*

LEGEND:

HP

81.4 505

50.2/75.3 213.6/213.6 250/250

40

25.4 30 /40

100.4

20 /30

* *
*

10

* *
50*/60*

50.2/75.3 200.2/200.2 250/250

110

10 12.4 20 /30
40

50.2/75.3 194.2/194.2 250/250

150

* *
*

ELECTRIC
HEATER

BM

RLA LRA HP FLA Nom. kW

87.6

* *
40*

- Full Load Amps

250

123.7

15 19.4 20 /30

FLA

194.2

FLA

460-3-60

MOCP

60.8

7.5

MCA

COMPRESSOR
(2 EA)

modules

17

15

20

24

32

30 /40

* *
50*/60*
30 /40

10

* *
* *

15

230.2

300

FLA

75.3/100.4 230.2/230.2 300/300


125.5/150.6 230.2/230.2 300/300

243.6

300

75.3/100.4 243.6/243.6 300/300


125.5/150.6 243.6/243.6 300/300

254.8

300

75.3/100.4 254.8/254.8 300/300


125.5/150.6 254.8/254.8 300/300

121.1

150

45.6/60.8 121.1/121.1 150/150


76/91.2

121.1/133.5 150/150
129.5

150

45.6/60.8 129.5/129.5 150/150


76/91.2

129.5/144

150/150

137.5

175

45.6/60.8 137.5/137.5 175/175


76/91.2

137.5/154
98.8

175/175
125
125/125

37.7/50.2

98.8/98.8

50 /60

62.8/75.3

98.8/109.6 125/125

* *
* *

19.4 30 /40
50 /60

20

MOCP

12.4 30 /40

33.6 225

MCA

25

* *
50*/60*
30 /40

105.8

125

37.7/50.2 105.8/105.8 125/125


62.8/75.3 105.8/118.4 125/125

111.4

125

37.7/50.2 111.4/111.4 125/125


62.8/75.3 111.4/125.4 125/150

ELECTRICAL DATA
(Dual scroll compressor units)
MODEL NUMBER

DESCRIPTION

PMY 540

VOLTAGE
RANGE

POWER SUPPLY
(V-Ph-Hz)

Min.

Max.

(4 EA )

COMPRESSOR
(2 EA)

FLA

RLA LRA HP FLA Nom. kW

FM

BM

ELECTRIC
HEATER

* *
* *

15 38.8 30 /40
50 /60

208/230-3-60

187

253

5.4

87.9 500
&
&
81.4 505

20

50

* *
50*/60*
30 /40

25

66

* *
50*/60*
30 /40

15

24

* *
50*/60*
30 /40

380-3-60
(4 WIRE)

342

418

2.7

54.3 305
&
&
42.1 280

20

32

* *
50*/60*
30 /40

25

36

* *
50*/60*
30 /40

* *
* *

414

506

2.7

42.9 250
&
&
33.6 225

HP

- Horse Power

BM

- Blower Motor

FM

- Fan Motor (Condenser)

LRA

- Locked Rotor Amps

RLA

- Rated Load Amps

300

ELECTRIC
HEATER

BM

RLA LRA HP FLA Nom. kW

75.3/100.4 251.7/251.7 300/300

15

* *
50*/60*

38.8 30 /40

125.5/150.6 251.7/251.7 300/300

262.9

350

75.3/100.4 262.9/262.9 350/350

87.9 500

20

50

125.5/150.6 262.9/262.9 350/350

278.9

350
25

66

125.5/150.6 278.9/278.9 350/350

144.8

175

15

24

144.8/144.8 175/175
152.8

* *
50*/60*
30 /40

45.6/60.8 144.8/144.8 175/175


76/91.2

* *
50*/60*
30 /40

75.3/100.4 278.9/278.9 350/350

200

* *
50*/60*
30 /40

76/91.2

152.8/154

200/200

* *
50*/60*

156.8

200

45.6/60.8 152.8/152.8 200/200

54.3 305

76/91.2

156.8/159
117.4

20

25

45.6/60.8 156.8/156.8 200/200

32

36

200/200
150

30 /40

* *
50*/60*
30 /40

* *
* *

MCA

MOCP

258.2

300

FLA

75.3/100.4 258.2/258.2 300/300


125.5/150.6 258.2/258.2 300/300

269.4

350

75.3/100.4 269.4/269.4 350/350


125.5/150.6 269.4/269.4 350/350

285.4

350

75.3/100.4 285.4/285.4 350/350


125.5/150.6 285.4/285.4 350/350

157

200

45.6/60.8

157/157

200/200

76/91.2

157/157

200/200

165

200

45.6/60.8

165/165

200/200

76/91.2

165/165

200/200

169

200

45.6/60.8

169/169

200/200

76/91.2

169/169
126.7

200/200
150

37.7/50.2 117.4/117.4 150/150

15 19.4 30 /40

37.7/50.2 126.7/126.7 150/150

62.8/75.3 117.4/118.4 150/150

50 /60

62.8/75.3 126.7/126.7 150/150

20

25

* *
50*/60*
30 /40

33

* *
50*/60*

30 /40

123

150

37.7/50.2

123/123

150/150

62.8/75.3

131

150

37.7/50.2

131/131

150/150

62.8/75.3

131/135.4

150/150

MOCP - Maximum Over Current Protection


modules

18

42.9 250

20

25

123/125.4 150/150

MCA - Minimum Circuit Amps

*Combination of heater

251.7

FLA

LEGEND:
- Full Load Amps

MOCP

50 /60

25

FLA

MCA

15 19.4 30 /40

460-3-60

PMY 600
COMPRESSOR
(2 EA)

* *
50*/60*
30 /40

25

33

* *
50*/60*
30 /40

132.3

175

37.7/50.2 132.3/132.3 175/175


62.8/75.3 132.3/132.3 175/175

140.3

175

37.7/50.2 140.3/140.3 175/175


62.8/75.3 140.3/140.3 175/175

19

253

418

506

187

342

414

208/230-3-60

380-3-60
(4 WIRE)

460-3-60

Fan Motor (Condenser)


Locked Rotor Amps
Rated Load Amps

Full Load Amps


Horse Power
Blower Motor

2.7

2.7

5.4

FLA

(2 EA for
PMY240/300 &
3 EA for 360)

FM
BM

28.4 158

34.9 201

56.8 361.5

12.4

9.7

7.5

10

15.6

12.5

7.5

10

25.4

19.4

10

7.5

25.1/37.7
50.2

40*

12.6/18.8

10*/15*
20*/30*

50.2

12.6/18.8

10*/15*

40*

25.1/37.7

60.8

40*

20*/30*

30.4/45.6

15.2/22.8

10*/15*
20*/30*

60.8

15.2/22.8

10*/15*

40*

30.4/45.6

100.4

40*

20*/30*

50.2/75.3

25.1/37.7

10*/15*
20*/30*

100.4

40*

50.2/75.3

20*/30*

25.1/37.7

10*/15*

FLA

ELECTRIC
HEATER

RLA LRA HP FLA Nom. KW

COMPRESSOR

150

MOCP

150
150

78.3

53.3/62.6

53.3/53.3

53.3

74.9

50.6/59.3

50.6/50.6

50.6

95.5

64.6/76.5

64.6/64.6

64.6

91.6

61.5/72.6

61.5/61.5

61.5

157.3

80

80/80

80/80

80

80

70/70

70/70

70

100

90/90

90/90

90

100

90/90

90/90

90

175

107.2/125.9 150/150

107.2/107.2 150/150

107.2

149.8

101.2/118.4 150/150

101.2/101.2 150/150

101.2

MCA

PMY 240 (Single semi-hermetic compressor unit)

Minimum Circuit Amps


Maximum Over Current Protection
*Combination of heater modules

FLA HP
BM
FM
LRA RLA MCA MOCP -

LEGEND:

Max.

VOLTAGE
RANGE

Min.

POWER
SUPPLY
(V-Ph-Hz)

DESCRIPTION

BM

34.7 184

41.6 227

75.9 361.5

10

7.5

10

7.5

10

7.5

12.4

9.7

15.6

12.5

25.4

19.4

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

40*

20*/30*

10*/15*

50.2

25.1/37.7

12.6/18.8

50.2

25.1/37.7

12.6/18.8

60.8

30.4/45.6

15.2/22.8

60.8

30.4/45.6

15.2/22.8

100.4

50.2/75.3

25.1/37.7

100.4

50.2/75.3

25.1/37.7

FLA

ELECTRIC
HEATER

RLA LRA HP FLA Nom. KW

COMPRESSOR

78.3

61.2/62.6

61.2/61.2

61.2

74.9

58.5/59.2

58.5/58.5

58.5

95.5

73/76.5

73/73

73

91.6

69.9/72.6

69.9/69.9

69.9

157.3

131.1/131.1

131.1/131.1

131.1

149.8

125.1/125.1

125.1/125.1

125.1

MCA

90

90/90

90/90

90

90

90/90

90/90

90

110

110/110

110/110

110

100

100/100

100/100

100

200

200/200

200/200

200

200

200/200

200/200

200

MOCP

PMY 300 (Single semi-hermetic compressor unit)

MODEL NUMBER

(Semi-hermetic compressor units)

ELECTRICAL DATA

BM

25.5 123

30.6 152

53.6 263

15

10

7.5

15

10

7.5

15

10

7.5

19.4

12.4

9.7

24

15.6

12.5

38.8

25.4

19.4

50.2/75.3
100.4

20*/30*
40*

30.4/45.6
60.8

30.4/45.6
60.8

20*/30*
40*

20*/30*
40*

25.1/37.7
50.2

25.1/37.7
50.2

20*/30*
40*

20*/30*
40*

40*

20*/30*

50.2

25.1/37.7

60.8

156.2

101.1

95.5

92.6/92.6

92.6

91.6

89.5/89.5

89.5

175.6

175.6/175.6

175.6

162.2

162.2/162.2

162.2

87

84.9/84.9

84.9

78.3

77.9/77.9

77.9

75.2

75.2/75.2

75.2

106

30.4/45.6 101.1/101.1
40*

20*/30*

100.4

50.2/75.3
40*

20*/30*

100.4

156.2

MCA

200

MOCP

100

100/100

100

100

100/100

100

100

100/100

100

125

125/125

125

110

110/110

110

110

110/110

110

200

200/200

200

200

200/200

200

200

50.2/75.3 156.2/156.2 200/200

40*

20*/30*

FLA

ELECTRIC
HEATER

RLA LRA HP FLA Nom. KW

COMPRESSOR
(2 EA)

PMY 360 (Dual semi-hermetic compressor unit)

ELECTRICAL DATA
(Dual semi-hermetic compressor units)
MODEL NUMBER

DESCRIPTION

PMY 420

PMY 480

FM

VOLTAGE
RANGE

POWER SUPPLY
(V-Ph-Hz)

Min.

Max.

COMPR(3 EA for
ESSOR
PMY420 &
(2 EA)
4 EA for 480)
FLA

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

* *
40*

7.5 19.4 20 /30

208/230-3-60

187

253

5.4

60.9 390

* *
40*

10 25.4 20 /30

* *
40*

15 38.8 20 /30

418

2.7

33.2 186

460-3-60

414

506

2.7

27.6 154

100.4

171.6

225

* *
50*/60*

177.6

225

100.4

177.6

225

* *
50*/60*

191

250

50.2/75.3

191/191

250/250

100.4

191

250

* *
50*/60*

95.5

125

30.4/45.6

95.5/95.5

125/125

50.2/75.3 177.6/177.6 225/225

BM

- Blower Motor

FM

- Fan Motor (Condenser)

LRA

- Locked Rotor Amps

RLA

- Rated Load Amps

50

30 /40

125/125

60.8

98.6

125

* *
50*/60*

107

125

30.4/45.6

107/107

125/125

60.8

107

125

79.9

100

20 /30

25.1/37.7

79.9/79.9

100/100

40

50.2

79.9

100

82.6

100

25.1/37.7

82.6/82.6

100/100

50.2

82.6

100

89.6

110

25.1/37.7

89.6/89.6

110/110

50.2

89.6

110

* *
40*

20 /30

* *
*
* *
*

10 12.4 20 /30
40

MCA - Minimum Circuit Amps


MOCP - Maximum Over Current Protection

*Combination of heater

20

38.8

98.6/98.6

LEGEND:

- Horse Power

56.8 361.5 15

30 /40

30.4/45.6

* *
40*

HP

25.4 30 /40

15 19.4 20 /30

- Full Load Amps

10

50.2/75.3 171.6/171.6 225/225

125

FLA

125

9.7

RLA LRA HP FLA Nom. kW

95.5

7.5

225

98.6

* *
40*

24

10 15.6 20 /30

15

171.6

FLA

ELECTRIC
HEATER

BM

60.8

342

MOCP

* *
50*/60*

* *
40*

7.5 12.5 20 /30

380-3-60
(4 WIRE)

MCA

COMPRESSOR
(2 EA)

modules

20

10

34.9 201

15

20

15.6 30 /40

24

32

30 /40

* *
50*/60*
30 /40

15

225

75.3/100.4 174.8/174.8 225/225


125.5/150.6 188.6/220

188.2

225/225
225

75.3/100.4 188.2/188.2 225/225


125.5/150.6 205.4/236.8 225/225

199.4

250

75.3/100.4 199.4/199.4 250/250


125.5/150.6 219.4/250.8 250/250

104.9

125

45.6/60.8 104.9/104.9 125/125


76/91.2

114.5/133.5 125/150
113.3

125

45.6/60.8 113.3/113.3 125/125


76/91.2

125/144

125/150

121.3

150

45.6/60.8 121.3/121.3 150/150


150/175
110

12.4 30 /40

37.7/50.2

87.1/87.1

110/110

50 /60

62.8/75.3

94/109.6

110/110

94.1

110

37.7/50.2

94.1/94.1

110/110

* *
* *
* *
* *

19.4 30 /40
50 /60

20

174.8

FLA

135/154
87.1

28.4 158

MOCP

76/91.2

10

MCA

25

* *
50*/60*
30 /40

62.8/75.3 102.8/118.4 110/125

99.7

125

37.7/50.2

99.7/99.7

125/125

62.8/75.3 109.8/125.4 125/150

ELECTRICAL DATA
(Dual semi-hermetic compressor units)
MODEL NUMBER

DESCRIPTION

PMY 540

VOLTAGE
RANGE

POWER SUPPLY
(V-Ph-Hz)

Min.

Max.

(4 EA )

COMPRESSOR
(2 EA)

FLA

RLA LRA HP FLA Nom. kW

FM

BM

ELECTRIC
HEATER

* *
* *

15 38.8 30 /40
50 /60

208/230-3-60

187

253

5.4

75.9 439

20

50

* *
50*/60*
30 /40

25

66

* *
50*/60*
30 /40

15

24

* *
50*/60*

30 /40

380-3-60
(4 WIRE)

342

418

2.7

41.6 227

20

32

* *
50*/60*

30 /40

25

36

* *
50*/60*
30 /40

* *
* *

414

506

2.7

34.7 184

- Horse Power

BM

- Blower Motor

FM

- Fan Motor (Condenser)

LRA

- Locked Rotor Amps

RLA

- Rated Load Amps

RLA `

HP FLA Nom. kW

15

* *
50*/60*

38.8 30 /40

125.5/150.6 231.4/236.8 300/300

242.6

300

75.3/100.4 242.6/242.6 300/300

88

537

20

50

125.5/150.6 242.6/250.8 300/300

258.6

300
25

66

125.5/150.6 258.6/270.8 300/300

128.4

* *
50*/60*
30 /40

75.3/100.4 258.6/258.6 300/300


150

* *
50*/60*
30 /40

76/91.2

128.4/144

150/150

* *
50*/60*

136.4

175

45.6/60.8 128.4/128.4 150/150

15

24

30 /40

76/91.2

136.4/154

175/175

* *
50*/60*

140.4

175

45.6/60.8 136.4/136.4 175/175

48.2 255

76/91.2

140.4/159
108.3

20

25

45.6/60.8 140.4/140.4 175/175

32

36

175/175
125

30 /40

* *
50*/60*
30 /40

* *
* *

MCA

MOCP

258.4

300

FLA

75.3/100.4 258.4/258.4 300/300


125.5/150.6 258.4/258.4 300/300

269.6

350

75.3/100.4 269.6/269.6 350/350


125.5/150.6 269.6/269.6 350/350

285.6

350

75.3/100.4 285.6/285.6 350/350


125.5/150.6 285.6/285.6 350/350

143.3

175

45.6/60.8 143.3/143.3 175/175


76/91.2

143.3/144 175/175
151.3

200

45.6/60.8 151.3/151.3 200/200


76/91.2

151.3/154 200/200
155.3

200

45.6/60.8 155.3/155.3 200/200


76/91.2

155.3/159 200/200
120.7
150

15 19.4 30 /40

37.7/50.2 120.7/120.7 150/150

62.8/75.3 108.3/118.4 125/125

50 /60

62.8/75.3 120.7/120.7 150/150

20

25

* *
50*/60*
30 /40

33

* *
50*/60*

30 /40

113.9

125

62.8/75.3 113.9/125.4 125/150

* *
50*/60*

121.9

37.7/50.2 113.9/113.9 125/125

62.8/75.3 121.9/135.4 150/150

MOCP - Maximum Over Current Protection


modules

21

40.2 209

20

25

150

37.7/50.2 121.9/121.9 150/150

MCA - Minimum Circuit Amps

*Combination of heater

300

75.3/100.4 231.4/231.4 300/300

LEGEND:

HP

231.4

FLA

ELECTRIC
HEATER

BM

37.7/50.2 108.3/108.3 125/125

25

- Full Load Amps

MOCP

50 /60

FLA

MCA

15 19.4 30 /40

460-3-60

PMY 600
COMPRESSOR
(2 EA)

25

33

30 /40

* *
50*/60*
30 /40

126.3

150

37.7/50.2 126.3/126.3 150/150


62.8/75.3 126.3/126.3 150/150

134.3

175

37.7/50.2 134.3/134.3 175/175


62.8/75.3 134.3/135.4 175/175

ELECTRICAL DATA
(Dual semi-hermetic compressor units)
MODEL NUMBER

DESCRIPTION

PMY 720

PMY 840

FM

VOLTAGE
RANGE

POWER SUPPLY
(V-Ph-Hz)

Min.

Max.

COMPR(5 EA for
ESSOR
PMY720 &
(2 EA)
6 EA for 840)
FLA

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

* *
* *

15 38.8 30 /40
50 /60

208/230-3-60

187

253

5.4

85.5 600

20

50

* *
50*/60*

30 /40

25

66

* *
50*/60*

30 /40

15

24

* *
50*/60*

30 /40

380-3-60
(4 WIRE)

342

418

2.7

52.6 333

20

32

* *
50*/60*

30 /40

25

36

* *
50*/60*

30 /40

* *
* *

414

506

2.7

42.8 262

- Horse Power

BM

- Blower Motor

FM

- Fan Motor (Condenser)

LRA

- Locked Rotor Amps

RLA

- Rated Load Amps

15

* *
50*/60*

38.8 30 /40

125.5/150.6 258.2/258.2 300/300

269.4

350

75.3/100.4 269.4/269.4 350/350

120.2 611

20

50

125.5/150.6 269.4/269.4 350/350

285.4

350
25

66

125.5/150.6 285.4/285.4 350/350

155.9

200

65.9 338

20

32

163.9/163.9 200/200
167.9

* *
50*/60*
30 /40

200

* *
50*/60*
30 /40

25

45.6/60.8 167.9/167.9 200/200


76/91.2

24

200

45.6/60.8 163.9/163.9 200/200


76/91.2

15

155.9/155.9 200/200
163.9

* *
50*/60*
30 /40

45.6/60.8 155.9/155.9 200/200


76/91.2

* *
50*/60*
30 /40

75.3/100.4 285.4/285.4 350/350

36

167.9/167.9 200/200
129.2
150

* *
50*/60*
30 /40

* *
* *

MOCP

341.7

450

FLA

75.3/100.4 341.7/341.7 450/450


125.5/150.6 341.7/341.7 450/450

352.9

450

75.3/100.4 352.9/352.9 450/450


125.5/150.6 352.9/352.9 450/450

368.9

450

75.3/100.4 368.9/368.9 450/450


125.5/150.6 368.9/368.9 450/450

188.5

250

45.6/60.8 188.5/188.5 250/250


76/91.2

188.5/188.5 250/250
196.5

250

45.6/60.8 196.5/196.5 250/250


76/91.2

196.5/196.5 250/250
200.5

250

45.6/60.8 200.5/200.5 250/250


76/91.2

200.5/200.5 250/250
159.1
200

15 19.4 30 /40

37.7/50.2 159.1/159.1 200/200

62.8/75.3 129.2/129.2 150/150

50 /60

62.8/75.3 159.1/159.1 200/200

20

25

* *
50*/60*
30 /40

33

* *
50*/60*

30 /40

134.8

175

62.8/75.3 134.8/134.8 175/175

* *
50*/60*

142.8

37.7/50.2 134.8/134.8 175/175

62.8/75.3 142.8/142.8 175/175

MOCP - Maximum Over Current Protection


modules

22

54.9 273

20

25

175

37.7/50.2 142.8/142.8 175/175

MCA - Minimum Circuit Amps

*Combination of heater

RLA LRA HP FLA Nom. kW

75.3/100.4 258.2/258.2 300/300

LEGEND:

HP

300

MCA

37.7/50.2 129.2/129.2 150/150

25

- Full Load Amps

258.2

FLA

ELECTRIC
HEATER

BM

50 /60

FLA

MOCP

15 19.4 30 /40

460-3-60

MCA

COMPRESSOR
(2 EA)

25

33

30 /40

* *
50*/60*
30 /40

164.7

200

37.7/50.2 164.7/164.7 200/200


62.8/75.3 164.7/164.7 200/200

172.7

225

37.7/50.2 172.7/172.7 225/225


62.8/75.3 172.7/172.7 225/225

23

0.4

0.4

2.84

670

6500

2.31

4.83

713

8500

7.04

7.51

7.98

796

803

809

10400

10700

11000

0.6

854

835

815

812

809

801

797

792

778

769

760

750

740

722

704

RPM

769

760

750

740

722

704

703

702

698

693

676

658

RPM

0.6

8.09

7.67

7.25

6.83

6.41

6.20

5.83

5.47

5.36

4.88

4.41

4.20

3.99

3.68

3.36

BHP

4.88

4.41

4.20

3.99

3.68

3.36

3.24

3.13

2.98

2.84

2.47

2.10

BHP

0.8

890

871

851

843

834

821

818

814

808

805

801

796

790

775

760

RPM

805

801

796

790

775

760

754

748

734

720

710

700

RPM

0.8

8.51

8.24

7.98

7.40

6.83

6.20

6.04

5.88

5.67

5.36

5.04

4.63

4.22

3.90

3.57

BHP

5.36

5.04

4.63

4.22

3.90

3.57

3.41

3.26

3.10

2.94

2.63

2.31

BHP

1.0

907

904

900

898

896

894

880

865

850

830

810

809

808

805

801

RPM

830

810

809

808

805

801

798

795

783

770

745

720

RPM

1.0

8.75

8.33

8.22

7.93

7.56

7.25

6.88

6.51

6.09

5.72

5.36

5.17

4.99

4.49

3.99

BHP

5.72

5.36

5.17

4.99

4.49

3.99

3.68

3.37

3.27

3.16

2.84

2.52

BHP

5.93

5.46

5.30

5.15

4.78

4.41

4.21

4.00

3.63

3.26

3.10

2.94

BHP

907

901

898

895

888

880

876

872

846

820

812

803

RPM

1.4

6.35

5.88

5.62

5.36

5.04

4.73

4.52

4.31

3.90

3.50

3.32

3.15

BHP

926

920

920

920

913

905

903

900

882

864

852

840

RPM

1.6

1.2

950

940

930

921

912

903

902

901

896

879

861

846

830

821

812

RPM

6.62

6.09

5.83

5.57

5.36

5.15

4.88

4.62

4.25

3.89

3.62

3.36

BHP

990

976

968

960

943

925

923

921

912

902

899

895

8.81

8.72

8.61

8.45

8.27

7.67

7.35

7.04

6.41

5.93

5.46

5.30

5.15

4.78

4.41

BHP

8.82

8.71

8.62

8.51

8.31

7.98

7.56

7.14

6.83

6.35

5.88

5.62

5.36

5.04

4.73

BHP

II
978

966

953

943

932

924

920

915

912

907

901

898

895

888

880

RPM

1.4

1011

1004

997

989

981

972

958

944

931

926

920

920

920

913

905

RPM

1.6

8.92

8.78

8.69

8.59

8.39

8.19

7.88

7.56

7.14

6.62

6.09

5.83

5.57

5.36

5.15

BHP

1022

1017

1011

1009

1007

1005

1005

1004

1004

990

976

968

960

943

925

RPM

1.8

8.97

8.92

8.71

8.64

8.53

8.22

8.24

8.19

8.09

7.51

6.93

6.51

6.09

5.72

5.36

BHP

7.51

6.93

6.51

6.09

5.72

5.36

5.09

4.83

4.44

4.05

3.76

3.48

BHP

II

RPM

1.8

EXTERNAL STATIC PRESSURE (inch wg.)

Model No.: PMY 300

879

861

846

830

821

812

812

812

807

801

791

780

RPM

1.2

EXTERNAL STATIC PRESSURE (inch wg.)

1031

1029

1028

1027

1026

1025

1024

1023

1021

1010

998

997

995

993

990

RPM

2.0

1010

998

997

995

993

990

986

981

953

924

922

920

RPM

2.0

8.93

8.91

8.88

8.73

8.88

8.72

8.66

8.51

8.19

7.72

7.25

7.19

7.14

6.35

5.57

BHP

7.72

7.25

7.19

7.14

6.35

5.57

5.36

5.15

4.47

3.79

3.69

3.59

BHP

1094

1091

1090

1086

1085

1084

1083

1082

1078

1051

1024

1022

1020

1013

1005

RPM

2.2

1051

1024

1022

1020

1013

1005

1004

1002

991

980

958

935

RPM

2.2

9.14

8.98

8.92

8.91

8.90

8.83

8.74

8.73

8.31

8.19

7.67

7.26

7.25

6.46

5.67

BHP

8.19

7.67

7.46

7.25

6.46

5.67

5.57

5.46

4.99

4.52

4.25

3.99

BHP

1113

1112

1109

1104

1102

1098

1097

1095

1094

1085

1075

1068

1060

1059

1057

RPM

9.31

9.20

9.06

8.98

8.94

8.94

8.81

8.82

8.42

8.40

7.98

7.35

6.72

6.46

6.20

BHP

8.40

7.98

7.35

6.72

6.46

6.20

5.88

5.57

5.41

5.25

4.83

4.41

BHP

2.4

1085

1075

1068

1060

1059

1057

1053

1048

1029

1010

991

971

RPM

2.4

8.66

8.09

7.67

7.25

6.93

6.91

6.88

6.74

6.30

5.46

5.15

4.84

BHP

1134

1131

1129

1124

1120

1118

1118

1117

1116

1106

1096

1093

1090

1085

1080

RPM

9.42

9.18

9.15

9.10

9.01

8.98

8.92

8.91

8.66

8.53

8.09

7.67

7.25

6.93

6.62

BHP

2.6

1106

1096

1093

1090

1085

1080

1078

1076

1053

1030

1024

1018

RPM

2.6

5. Alt. I & II drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I & II.

3. Alt. 10 HP motor to be used for the shaded portion.

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 7.5 HP motor.

6.20

6.62

790

793

9900

5.51

5.57

763

784

9300

9600

10100

5.36

5.46

720

741

8800

4.83

713

8500

9000

3.89

4.31

703

3.47

701

7600

705

3.30

692

7300

7900

3.13

682

8200

BHP

RPM

7000

AIRFLOW
(CFM)

3.89

4.31

703

705

7900

8200

3.30

3.47

692

701

7300

7600

2.98

3.13

676

682

6800

7000

2.57

620

645

2.07

6000

618

5700

1.84

BHP

6200

615

RPM

5400

AIRFLOW
(CFM)

Model No.: PMY 240

FAN PERFORMANCE DATA

24

8.64

8.93

724

728

12600

12800

782

766

750

734

718

716

715

713

711

709

707

705

703

697

691

684

678

671

664

657

650

640

631

621

611

RPM

BHP

9.35

9.03

8.72

8.40

8.09

7.85

7.61

7.38

7.14

6.95

6.76

6.57

6.38

6.13

5.87

5.61

5.36

5.09

4.83

4.57

4.31

4.12

3.94

3.75

3.57

0.6

799

794

789

783

778

771

764

757

750

743

736

729

722

718

714

710

706

703

701

698

695

683

671

659

647

RPM

0.8

9.35

9.14

8.93

8.72

8.51

8.27

8.03

7.80

7.60

7.35

7.14

6.93

6.72

6.41

6.09

5.78

5.46

5.33

5.20

5.07

4.94

4.70

4.47

4.24

4.01

BHP

822

817

812

806

801

796

791

786

781

777

772

768

763

751

739

726

714

713

712

711

710

703

695

688

680

RPM

9.66

9.19

8.72

8.56

8.40

8.24

8.09

7.80

7.51

7.22

6.93

6.69

6.46

6.22

5.99

5.78

5.57

5.36

5.15

4.94

4.73

4.52

4.31

BHP

10.61

10.13

1.0

850

843

836

828

821

816

812

807

802

800

798

796

794

791

789

786

783

770

758

745

732

726

720

714

708

RPM

1.2

10.71

10.26

9.82

9.37

8.93

8.74

8.56

8.37

8.19

8.01

7.82

7.64

7.46

7.14

6.83

6.51

6.20

6.04

5.88

5.72

5.57

5.30

5.04

4.78

4.52

BHP

878

868

859

849

839

834

830

825

820

817

814

811

808

806

804

802

800

799

797

796

794

785

776

766

757

RPM

9.95

9.66

9.42

9.19

8.95

8.72

8.56

8.40

8.24

8.09

7.82

7.56

7.30

7.04

6.80

6.56

6.33

6.09

5.86

5.64

5.41

5.19

BHP

10.82

10.53

10.24

1.4

901

899

896

894

891

885

880

874

868

857

846

834

823

822

822

821

820

816

812

807

803

802

801

799

798

RPM

9.71

9.27

8.82

8.69

8.56

8.43

8.30

8.01

7.72

7.43

7.14

6.91

6.67

6.44

6.21

6.02

5.83

5.65

5.46

BHP

11.13

11.00

10.87

10.74

10.61

10.16

1.6

911

909

907

904

902

898

894

889

885

881

877

873

869

865

860

856

851

849

847

844

842

836

830

823

817

RPM

9.74

9.35

9.14

8.93

8.72

8.51

8.35

8.19

8.03

7.88

7.53

7.19

6.85

6.51

6.30

6.08

5.87

5.66

BHP

11.76

11.55

11.34

11.13

10.92

10.53

10.13

1.8

EXTERNAL STATIC PRESSURE (inch wg.)

927

923

920

916

912

911

910

909

908

907

905

904

902

901

900

898

897

893

889

885

881

874

867

859

852

6.80

6.63

6.45

6.28

6.10

BHP

11.90

11.55

11.20

10.85

10.50

10.35

10.20

10.05

9.90

9.60

9.30

9.00

8.70

8.45

8.20

7.95

7.70

7.48

7.25

7.03

II

RPM

2.0

971

967

963

958

954

948

941

935

928

926

923

921

918

918

919

919

919

915

910

906

901

899

896

894

891

RPM

9.60

9.20

8.80

8.58

8.35

8.13

7.90

7.63

7.35

7.08

6.80

6.69

6.57

6.46

6.34

BHP

997

992

986

981

979

977

974

972

968

965

961

957

953

950

946

942

935

929

922

915

913

911

908

906

RPM

999

998

994

990

985

981

979

978

976

974

964

953

943

932

931

930

929

928

RPM

11.58

11.13

11.03

10.92

10.82

10.71

10.16

9.61

9.06

8.51

8.45

8.40

8.35

8.30

8.03

7.77

7.51

7.25

BHP

2.6

III

13.13 1008 13.55

12.71 1007 13.34

12.29 1005 13.13

11.87 1003 12.92

11.76 1002 12.47

11.66 1001 12.02

11.55

11.45

11.05

10.66

10.26

9.87

9.53

9.19

8.85

8.51

8.37

8.24

8.11

7.98

7.74

7.51

7.27

7.04

BHP

2.4

12.90 1002 13.55 1010 13.76

12.40

11.90

11.40

10.90

10.78

10.65

10.53

10.40

10.00

2.2

5. Alt. I, II & III drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I, II & III.

3. Alt. 15 HP motor to be used for the shaded portion.

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 7.5 & 10 HP motor respectively.

8.06

8.35

715

719

12200

12400

7.35

7.77

707

710

11800

6.93

12000

6.51

701

704

11400

11600

6.06

6.09

695

698

11000

11200

6.01

6.04

688

692

10650

10800

5.75

5.99

671

685

10350

5.51

658

10200

10500

5.04

5.28

630

644

9800

4.52

4.78

626

628

9400

9600

10000

3.99

4.25

621

623

3.83

612

8800

9000

3.68

603

8600

9200

3.36

3.52

584

593

8400

BHP

RPM

0.4

8200

AIRFLOW
(CFM)

Model No.: PMY 360

FAN PERFORMANCE DATA

25

10.92

801

14400

810

808

806

803

801

796

792

787

782

766

750

734

718

716

715

713

711

709

707

705

703

697

691

684

678

671

664

RPM

11.24

11.10

10.97

10.84

10.71

10.37

10.03

9.69

9.35

9.03

8.72

8.40

8.09

7.85

7.61

7.38

7.14

6.95

6.76

6.57

6.38

6.13

5.87

5.61

5.36

5.09

4.83

BHP

0.6

838

832

825

819

812

809

806

802

799

794

789

783

778

771

764

757

750

743

736

729

722

718

714

710

706

703

701

RPM

9.82

9.35

9.14

8.93

8.72

8.51

8.27

8.03

7.80

7.56

7.35

7.14

6.93

6.72

6.41

6.09

5.78

5.46

5.33

5.20

BHP

12.08

11.87

11.66

11.45

11.24

10.76

10.29

0.8

881

868

856

843

830

828

826

824

822

817

812

806

801

796

791

786

781

777

772

768

763

751

739

726

714

713

712

RPM

9.66

9.19

8.72

8.56

8.40

8.24

8.09

7.80

7.51

7.22

6.93

6.69

6.46

6.22

5.99

5.78

5.57

BHP

13.20

12.90

12.71

12.18

11.66

11.39

11.13

10.87

10.61

10.13

1.0

902

894

887

879

871

866

861

855

850

843

836

828

821

816

812

807

802

800

798

796

794

791

789

786

783

770

758

RPM

1.2

13.40

13.40

13.23

12.60

11.97

11.66

11.34

11.03

10.71

10.26

9.82

9.37

8.93

8.74

8.56

8.37

8.19

8.01

7.82

7.64

7.46

7.14

6.83

6.51

6.20

6.04

5.88

BHP

911

909

906

904

901

895

890

884

878

868

859

849

839

834

830

825

820

817

814

811

808

806

804

802

800

799

797

RPM

9.95

9.66

9.42

9.19

8.95

8.72

8.56

8.40

8.24

8.09

7.82

7.56

7.30

7.04

6.80

6.56

BHP
812

925

922

919

915

912

909

907

904

901

899

896

894

891

885

880

874

868

857

846

834

823

822

822

821

820

816

9.71

9.27

8.82

8.69

8.56

8.43

8.30

8.01

7.72

7.43

7.14

6.91

6.67

BHP

13.90

13.60

13.60

13.30

13.20

13.10

12.44

11.79

11.13

11.00

10.87

10.74

10.61

10.16

1.6
RPM

II
13.80

13.50

13.40

13.20

13.10

12.71

12.08

11.45

10.82

10.53

10.24

1.4

952

950

949

947

945

937

928

920

911

909

907

904

902

898

894

889

885

881

877

873

869

865

860

856

851

849

847

RPM

9.74

9.35

9.14

8.93

8.72

8.51

8.35

8.19

8.03

7.88

7.53

7.19

BHP

14.10

13.70

13.60

13.50

13.30

13.20

13.13

12.44

11.76

11.55

11.34

11.13

10.92

10.53

10.13

1.8

EXTERNAL STATIC PRESSURE (inch wg.)

974

973

972

971

970

959

949

938

927

923

920

916

912

911

910

909

908

907

905

904

902

901

900

898

897

893

889

RPM

9.90

9.60

9.30

9.00

8.70

8.45

8.20

7.95

7.70

7.48

7.25

BHP

14.10

13.90

13.80

13.70

13.50

13.30

13.20

12.50

11.90

11.55

11.20

10.85

10.50

10.35

10.20

10.05

2.0

997

992

986

981

979

977

974

972

968

965

961

957

953

950

946

942

935

929

RPM

999

998

994

990

985

981

979

978

976

974

964

953

RPM

11.58

11.13

11.03

10.92

10.82

10.71

10.16

9.61

9.06

8.51

8.45

8.40

BHP

13.13 1008 13.55

12.71 1007 13.34

12.29 1005 13.13

11.87 1003 12.92

11.76 1002 12.47

11.66 1001 12.02

11.55

11.45

11.05

10.66

10.26

9.87

9.53

9.19

8.85

8.51

8.37

8.24

BHP

2.6

13.70 1009 13.90 1016 14.40

13.60 1006 13.80 1013 14.20

13.45 1003 13.70 1012 14.10

12.90 1002 13.55 1010 13.76

12.40

11.90

11.40

10.90

10.78

10.65

10.53

10.40

10.00

9.60

9.20

8.80

8.58

8.35

8.13

7.90

7.63

7.35

BHP

2.4

1010 14.10 1018 14.40 1023 14.80

1008 14.00 1017 14.30 1022 14.70

1006 13.90 1016 14.20 1021 14.60

1004 13.80 1013 14.10 1019 14.50

1002 13.80 1011 14.00 1017 14.50

994

987

979

971

967

963

958

954

948

941

935

928

926

923

921

918

918

919

919

919

915

910

RPM

2.2

5. Alt. I & II drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I & II.

3. Alt. 15 HP motor to be used for the shaded portion.

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 10 HP motor.

10.72

10.82

782

791

14000

14200

10.51

10.61

762

772

13600

13800

9.72

10.11

745

754

13200

13400

8.93

9.32

728

737

12800

13000

8.35

8.64

719

724

12400

7.77

8.06

710

715

12000

12200

12600

6.93

7.35

704

707

11600

11800

6.09

6.51

698

701

11200

11000

11400

6.04

6.06

692

695

10800

5.99

6.01

685

688

10500

10650

5.51

5.75

658

671

10200

10350

5.04

5.28

630

644

9800

4.52

4.78

626

628

9600

10000

BHP

RPM

0.4

9400

AIRFLOW
(CFM)

Model No.: PMY 420

FAN PERFORMANCE DATA

26

10.78

11.2

11.72

847

851

860

16100

16400
16700
900

885

880

875

864

855

850

844

836

830

820

815

806

802

789

783

780

771

765

758

RPM

12.5

12

11.51

11

10.5

10.18

9.84

9.31

8.9

8.7

8.33

7.92

7.61

7.35

6.95

6.56

6.3

5.7

5.4

BHP

0.6

930

924

920

916

910

902

893

886

881

870

863

857

852

846

834

826

822

815

810

802

RPM

10

9.45

8.6

8.2

7.9

7.6

7.3

6.7

6.4

6.1

BHP

13.45

13.2

12.75

12.4

12

11.5

11.15

10.45

0.8

962

959

956

951

946

937

930

917

910

904

900

894

890

886

880

872

864

856

848

842

RPM

10.4

10

9.7

9.35

8.8

8.37

8.05

7.8

7.5

7.2

6.8

6.55

BHP

14.15

13.6

13.1

12.6

12.05

11.6

11.25

10.85

1.0

992

985

980

974

967

964

960

953

947

941

936

930

925

920

910

906

900

892

887

883

RPM

1.2

1001

994

990

982

976

970

966

964

962

956

950

944

937

931

926

920

RPM

14.8

15.1

14.6

14.1

13.7

13.26

12.84

12.42

12

11.48

11

10.6

10.2

9.8

9.5

9.2

8.84

8.5

8.2

7.9

BHP

1027 15.62

14.25 1021

13.74 1014

13.34 1010

13

12.6

12.05

11.55

11

10.5

10.1

9.7

9.4

8.7

8.4

8.1

7.8

7.5

7.3

BHP

1.4

11.6

11.2

10.8

10.4

10

9.7

9.28

8.7

8.46

BHP

1030

1027

1024

1020

1016

1012

1006

1056

1052

1048

1044

1040

1030

1018

1014

1010

16.3

15.6

15.1

14.6

14.2

13.8

13.4

13

12.6

1087

1084

1080

1076

1067

1060

1050

1044

1040

1041

1036

1030

RPM

1056

1053

1070

1066

1062

1104
1110

17.28 1117

16.68 1116

16.15 1113

15.7

15.2

14.68 1096

14.18 1090

13.76 1083

12.34 1074

12.9

12.4

12

11.52 1059

11.1

10.8

10.45 1050

9.7

BHP

17.4

16.95

16.4

16

15.9

15.84

15.34

14.75

14.2

13.67

13.2

12.63

12.1

11.65

11.32

11.03

10.7

10.33

10.04

2.0

10.05 1047

9.7

9.4

9.1

BHP

II

1002

995

990

RPM

1.8

1006 12.25 1035

998

992

990

984

981

977

971

965

960

955

RPM

1.6

EXTERNAL STATIC PRESSURE (inch wg.)

BHP
RPM
BHP

2.4
RPM

BHP

2.6

10.6
10.9

1102 11.32 1129 12.04


1107 11.71 1132 12.45
13.4

13.5

13

12.4

1122 13.36 1144 14.28

15.4

1159 16.15

17

16.4

17.8
1148

17.3

1173 18.08

1146 16.74 1170 17.61

1142 18.53

1140 18.05 1161 18.41

III

1137 17.55 1156 17.71 1179 18.57

1132

1125

1117 15.86 1144 16.31 1166

1112 15.32 1140 15.84 1164 16.56

1108 14.85 1134

15.6

1154 15.28
1100 14.36 1130 14.97 1156

14.5

1126 14.15 1152 14.98

1124 13.74 1147 14.66

1098 13.95 1128

1096

1094

1091

1085 12.05 1118 12.81 1141 13.81

1081 11.71 1115 12.42 1138

1074 10.33 1112 12.15 1135 12.95

1070

1066

1062 10.27 1098 10.95 1127 11.66

RPM

2.2

5. Alt. I, II & III drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I, II & III.

3. Alt. 20 HP motor to be used for the shaded portion.

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 10 & 15 HP motor respectively.

9.95

10.36

830

836

15500

9.55

823

15200

15800

8.87

9.14

805

8.46

800

14300

815

8.06

788

14000

14600

7.79

14900

7.38

772

778

13400

13700

6.7

6.97

762

766

6.3

755

12500

12800

13100

5.7

741

748

11900

5.4

726

11600

12200

5.2

716

719

11000

BHP

RPM

0.4

11300

AIRFLOW
(CFM)

Model No.: PMY 480

FAN PERFORMANCE DATA

27

14.17

14.7

908

18500

939

931

927

914

910

904

900

885

880

875

864

855

850

844

836

830

820

815

806

802

789

783

RPM

BHP

15.6

15.03

14.55

14

13.5

13

12.5

12

11.51

11

10.5

10.18

9.84

9.31

8.92

8.7

8.33

7.92

7.61

7.35

6.95

6.56

0.6

960

956

952

948

944

936

930

924

920

916

910

902

893

886

881

870

863

857

852

846

834

826

RPM

10

9.45

8.6

8.2

7.9

7.6

7.3

BHP

16.45

16.1

15.4

14.8

14.25

13.74

13.45

13.2

12.75

12.4

12

11.5

11.15

10.45

0.8

996

990

984

980

972

964

962

959

956

951

946

937

930

917

910

904

900

894

890

886

880

872

RPM

10.4

10

9.7

9.35

8.8

8.37

8.05

7.8

BHP

16.8

16.25

15.75

15.34

14.86

14.56

14.15

13.6

13.1

12.6

12.05

11.6

11.25

10.85

1.0

1040

1034

1022

1016

1008

1000

992

985

980

974

967

964

960

953

947

941

936

930

925

920

910

906

RPM

1.2

1001

994

990

982

976

970

966

964

962

956

950

944

RPM

1027 15.62

15.1

14.6

14.1

13.7

13.26

12.85

12.42

12

11.48

11

10.6

10.2

9.8

9.5

9.2

BHP

18

17.4

17

16.4

1070

1064

1058

1048

18.6

18.2

17.6

17.1

15.84 1040 16.61

15.41 1033 16.15

14.8

14.25 1021

13.74 1014

13.34 1010

13

12.6

12.05

11.55

11

10.5

10.1

9.7

9.4

8.7

8.4

BHP

1.4

1100

1091

1081

1074

1067

1060

1056

1052

1048

1044

1040

1030

1018

1014

1010

1006

998

992

990

984

981

977

RPM

11.6

11.2

10.8

10.4

10

9.7

BHP

1030

1027

1024

1020

1016

1012

RPM

20

19.65

19

18.3

17.6

16.9

16.3

15.6

15.1

14.6

14.2

13.8

13.4

13

12.6

1103

1098

1093

1087

1084

1080

1076

1067

1060

1050

1044

1040

BHP

RPM

1056

1053

1070

1066

1062

1110

1104

1130
18.85 1135

18.3

17.76 1119

17.28 1117

16.68 1116

16.15 1113

15.7

15.2

14.68 1096

14.18 1090

13.76 1083

13.34 1074

12.9

12.4

12

11.52 1059

11.1

10.8

BHP

RPM

1094
1098
1108

1140

1137

1132

20

19.4

18.7

17.4

II

1144

16.95 1142

16.4

16

15.4

15.84 1125

15.34 1117

14.75 1112

14.2

13.67 1100

13.2

12.63 1096

12.1

11.65 1091

11.32 1085

BHP
RPM
BHP

2.4
RPM

1122 13.36 1144 14.28

15.4

1159 16.15

1148 17.25 1173 18.08

1146 16.74 1170 17.61

18.86

18.53 1166 18.95

18.05 1161 18.41

17.55 1156 17.71 1179 18.57

17

16.4

15.86 1144 16.31 1166 17.18

15.32 1140 15.84 1164 16.56

14.85 1134

15.6

1154 15.28

14.36 1130 14.97 1156

14.5

1126 14.15 1152 14.98

1124 13.74 1147 14.66

13.95 1128

13.5

13

12.4

12.05 1118 12.81 1141 13.81

13.4

BHP

2.6

11.71 1115 12.42 1138

2.2

11.03 1081

2.0

10.45 1050

1.8

12.25 1035

1.6

EXTERNAL STATIC PRESSURE (inch wg.)

5. Alt. I & II drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I & II.

3. Alt. 20 HP motor to be used for the shaded portion.

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 15 HP motor.

13.82

895

900

13.12

17900

885

17600

12.77

12.25

11.72

18200

867

875

17000

17300

860

16700

11.2

10.78

847

851

16100

10.36

836

15800

16400

9.55

9.95

823

830

15200

15500

8.87

9.14

805

8.46

800

14300

815

8.06

788

14000

14600

7.79

14900

7.38

772

778

13400

13700

6.7

6.97

762

766

12800

13100

6.3

748

755

12200

BHP

RPM

0.4

12500

AIRFLOW
(CFM)

Model No.: PMY 540

FAN PERFORMANCE DATA

28

16.84

17.5

935

944

19700

20000

971

966

961

952

945

939

931

927

914

910

904

900

885

880

875

864

855

850

844

836

830

RPM

BHP

997

987

981

970

960

956

952

948

944

936

930

924

920

916

910

902

893

886

881

870

RPM
10

9.45

BHP

996

990

984

980

972

964

962

959

956

951

946

937

930

917

910

904

RPM

1028

1020

19.32 1034

18.6

18

17.42 1012

10.4

10

BHP

19.95

19.2

18.5

18

17.4

16.8

16.25

15.75

15.34

14.86

14.56

14.15

13.6

13.1

12.6

12.05

11.6

11.25

10.85

1.0

16.91 1002

16.45

16.1

15.4

14.8

14.25

13.74

13.45

13.2

12.75

12.4

12

11.5

11.15

10.45

0.8

18.33 1007

17.8

17.2

16.6

16.1

15.6

15.03

14.55

14

13.5

13

12.5

12

11.51

11

10.5

10.18

9.84

9.31

8.92

8.66

0.6

1066

1058

1050

1046

1043

1040

1034

1022

1016

1008

1000

992

985

980

974

967

964

960

953

947

941

RPM

1.2

1001

994

990

982

976

970

RPM

1027 15.62

15.1

14.6

14.1

13.7

13.26

12.85

12.42

12

11.48

BHP

1048

1070

1064

1058

20.6

20.1

19.7

19

17.1

20.5

20.1

19.7

19.3

18.6

18.2

17.6

1098 20.91

1094

1090

1084

18.45 1076

18

17.4

17

16.4

15.84 1040 16.61

15.41 1033 16.15

14.8

14.25 1021

13.74 1014

13.34 1010

13

12.6

12.05

11.55

11

10.5

BHP

1.4
BHP

RPM

19

18.3

17.6

16.9

16.3

15.6

15.1

14.6

14.2

13.8

13.4

13

12.6

1110

1103

1098

1093

1087

1084

1080

1076

1067

1060

1050

1044

1040

20
20.5

1128
1134

1132 22.42 1162

1127 21.95 1156

1120 21.42 1146

1113 21.03 1140

1107

1100

1091 19.65 1118

1081

1074

1067

1060

1056

1052

1048

1044

1040

1030

1018

1014

1010

12.9

BHP
1070

RPM

13.76 1083

1110

1104

1130

1158

22.31 1180

21.92 1178

21.56 1176

21.15 1170

20.73 1164

20.4

19.94 1150

19.43 1145

18.85 1135

18.3

17.76 1119

17.28 1117

16.68 1116

16.15 1113

15.7

15.2

14.68 1096

14.18 1090

BHP

22.8

22.78

22.76

22.28

21.75

21.38

20.94

20.42

20

19.4

18.7

17.4

16.95

16.4

16

15.4

15.84

15.34

14.75

14.2

13.68

2.0

13.34 1074

1.8

1006 12.25 1035

RPM

1.6

EXTERNAL STATIC PRESSURE (inch wg.)

BHP
RPM
BHP

2.4

15.4

15.6

1159 16.15

17

16.4

1148 17.25 1173 18.08

1146 16.74 1170 17.61

19.2

20

20

1206 20.92
1182 21.61 1212 21.42

22.5
1208 22.95

1206 22.92

1198

22.5

22
1212 22.58

1190 21.92 1208

1182 21.36 1204

22.4

III

1238 22.98

1232 22.92

1172 20.86 1198 21.58 1226

1164 20.53 1191 21.14 1220 21.85

1151

1146 19.38 1176

1144 18.86 1170 19.42 1198 20.32

1142 18.53 1166 18.95 1190 19.73

1140 18.05 1161 18.41 1184

1137 17.55 1156 17.71 1179 18.57

1132

1125

1117 15.86 1144 16.31 1166 17.18

1112 15.32 1140 15.84 1164 16.56

1108 14.85 1134

BHP

II

RPM

2.6

1100 14.36 1130 14.97 1156

RPM

2.2

5. Alt. I, II & III drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I, II & III.

3. Alt. 25 HP motor to be used for the shaded portion.

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 15 & 20 HP motor respectively.

15.75

16.18

922

930

19100

19400

14.7

15.22

908

917

18500

14.17

18800

900

18200

13.82

13.12

885

895

12.77

875

17300

17600

12.25

17900

11.72

860

867

16700

11.2

17000

10.78

847

851

16100

10.36

836

15800

16400

9.55

9.95

823

830

15200

15500

8.87

9.14

805

815

14600

8.46

14900

8.06

788

800

14000

BHP

RPM

0.4

14300

AIRFLOW
(CFM)

Model No.: PMY 600

FAN PERFORMANCE DATA

29

16.96

17.56

764

772

23700

24000

815

808

803

798

790

784

780

775

773

766

760

757

754

752

747

737

731

726

721

719

714

710

705

701

696

693

RPM

18.98

18.57

17.97

17.36

16.88

16.47

15.95

15.57

15.26

14.8

14.3

13.91

13.65

13.25

12.86

12.33

11.94

11.55

11.15

10.76

10.5

10.11

9.91

9.54

9.25

9.06

BHP

0.6

836

832

829

822

819

815

812

806

802

794

788

785

779

775

769

766

761

758

753

749

745

739

736

731

729

725

RPM
9.95

9.66

BHP

19.9

19.38

18.98

18.33

17.81

17.36

16.88

16.35

16.07

15.62

15.1

14.8

14.34

14

13.57

13.3

12.88

12.4

11.9

11.65

11.26

10.88

10.5

10.23

0.8

863

859

854

847

843

840

835

832

830

823

820

816

812

808

800

796

791

788

785

781

778

772

770

765

762

759

RPM
BHP

20.8

20.2

19.71

19.25

18.66

18.2

17.77

17.3

17

16.54

16

15.5

15.2

14.87

14.37

14

13.52

13.25

12.87

12.5

12.12

11.75

11.34

10.87

10.54

10.32

1.0

887

885

879

872

870

867

863

860

852

848

843

841

836

831

828

826

823

819

816

812

808

805

802

797

795

793

RPM

1.2

21.75

21.23

20.62

19.95

19.57

19.2

18.71

18.18

17.87

17.46

16.84

16.4

15.9

15.51

15.15

14.79

14.31

13.96

13.6

13.24

13

12.52

12.25

11.84

11.35

11.16

BHP

915

910

908

900

897

892

886

882

880

876

873

869

867

862

858

855

853

850

847

845

841

838

834

830

826

823

RPM

BHP

22.86

22.3

21.64

21

20.43

19.95

19.57

19.15

18.83

18.37

17.91

17.4

16.83

16.36

16

15.51

15.11

14.8

14.33

14.1

13.8

13.34

12.9

12.52

12.28

11.95

1.4

936

932

931

929

926

918

914

910

908

903

900

896

890

887

885

881

878

876

874

872

870

868

866

861

858

855

RPM

BHP

23.09

23.07

22.61

22.1

21.68

21

20.62

20

19.65

19.2

18.71

18.3

17.8

17.4

16.95

16.36

15.95

15.45

15.17

14.83

14.5

14.15

13.8

13.46

13.12

12.78

1.6

950

948

944

942

940

938

932

929

926

924

920

916

913

910

907

904

901

899

897

894

891

889

887

885

RPM
BHP

23.16

23.14

22.46

22

21.45

21

20.56

20

19.56

19.1

18.66

18.22

17.64

17.3

16.91

16.47

16.04

15.64

15.31

15

14.58

14.3

14

13.62

1.8

EXTERNAL STATIC PRESSURE (inch wg.)

966

964

962

957

955

952

948

946

942

941

938

935

932

929

925

923

921

918

916

914

912

RPM

BHP

23

22.46

21.9

21.5

21

20.5

20.18

19.81

19.4

18.95

18.46

17.93

17.5

17.06

16.62

16.18

15.75

15.46

15.1

14.78

14.48

2.0

989

982

980

978

976

974

973

972

970

966

964

962

960

958

956

954

952

949

946

RPM
15.1

23

22.2

21.6

21

20.6

20.1

19.67

19.25

18.9

18.37

18

17.67

17.15

16.8

16.3

16.03

15.75

RPM

BHP

2.6

1000 16.93

19.6

20.8

21.6

21.2

1004 22.75

III

1021

22.8

1020 22.28

20.58 1017 21.64

20.12 1016 21.21

19.67 1015

20.3

1010 19.95
19.25 1012

18.9

18.9
1006 19.25
18.55 1008

18.2

17.75 1004

17.15 1002 18.27

16.87 1000 17.86

16.52 1000 17.27

16.1

15.75 1000 16.59

1002 22.31

999

997

995

992

990

988

987

985

983

982

981

980

978

976

974

BHP

2.4
RPM

II

BHP
15.45

2.2

5. Alt. I, II & III drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I, II & III.

3. Alt. 25 HP motor to be used for the shaded portion.

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 15 & 20 HP motor respectively.

16.07

16.55

755

758

23100

15.58

23400

15.07

741

748

22500

14.73

22800

14.32

736

738

21900

13.9

22200

13.61

732

13.22

730

21000

734

12.85

728

20700

21300

12.5

21600

12.12

717

721

20100

11.8

712

19800

20400

11.1

11.42

702

706

19200

19500

10.4

10.76

692

698

18600

10.1

18900

9.81

681

686

18000

18300

9.23

9.52

673

676

8.9

667

17100

17400

8.64

17700

8.35

659

662

16500

BHP

RPM

0.4

16800

AIRFLOW
(CFM)

Model No.: PMY 720

FAN PERFORMANCE DATA

30

16.96

17.56

764

772

23700

24000

815

808

803

798

790

784

780

775

773

766

760

757

754

752

747

737

RPM
BHP

18.98

18.57

17.97

17.36

16.88

16.47

15.95

15.57

15.26

14.8

14.3

13.91

13.65

13.25

12.86

12.33

0.6

836

832

829

822

819

815

812

806

802

794

788

785

779

775

769

766

RPM
13.3

BHP

19.9

19.38

18.98

18.33

17.81

17.36

16.88

16.35

16.07

15.62

15.1

14.8

14.34

14

13.57

0.8

863

859

854

847

843

840

835

832

830

823

820

816

812

808

800

796

RPM
14

BHP

20.8

20.2

19.71

19.25

18.66

18.2

17.77

17.3

17

16.54

16

15.5

15.2

14.87

14.37

1.0

887

885

879

872

870

867

863

860

852

848

843

841

836

831

828

826

RPM

1.2

21.75

21.23

20.62

19.95

19.57

19.2

18.71

18.18

17.87

17.46

16.84

16.4

15.9

15.51

15.15

14.79

BHP

915

910

908

900

897

892

886

882

880

876

873

869

867

862

858

855

RPM

BHP

22.86

22.3

21.64

21

20.43

19.95

19.57

19.15

18.83

18.37

17.91

17.4

16.83

16.36

16

15.51

1.4

932

931

929

926

918

914

910

908

903

900

896

890

887

885

881

RPM

BHP

23.07

22.61

22.1

21.68

21

20.62

20

19.65

19.2

18.71

18.3

17.8

17.4

16.95

16.36

1.6

948

944

942

940

938

932

929

926

924

920

916

913

910

RPM
17.3

BHP

23.14

22.46

22

21.45

21

20.56

20

19.56

19.1

18.66

18.22

17.64

1.8

EXTERNAL STATIC PRESSURE (inch wg.)

966

964

962

957

955

952

948

946

942

941

938

RPM

BHP

23

22.46

21.9

21.5

21

20.5

20.18

19.81

19.4

18.95

18.46

2.0

989

982

980

978

976

974

973

972

970

RPM
18.9

BHP

23

22.2

21.6

21

20.6

20.1

19.67

19.25

2.2

3. Alt. 25 HP motor to be used for the shaded portion.

5. Alt. I & II drive packages are included in the respective motor selection.

4. Bordered regions indicate alternative drives I & II.

20.8

BHP

21.6

21.2

1021

22.8

1020 22.28

20.58 1017 21.64

20.12 1016 21.21

1004 22.75

II

RPM

2.6

19.67 1015

BHP

1002 22.31

999

997

995

992

990

RPM

2.4

Notes: 1. Values include losses for 2" filters (dirty condition), unit casing, drive losses & wet coils. If any accessories used such as bag filters, heater module .etc ., add
accessories
pressure drop to External Static Pressure before using fan performance tables.
2. Unshaded bordered regions indicates standard 20 HP motor.

16.07

16.55

755

758

23100

15.58

23400

15.07

741

748

22500

14.73

22800

14.32

736

738

21900

13.9

22200

13.61

732

13.22

730

21000

734

12.85

728

20700

21300

12.5

21600

12.12

717

721

20100

11.8

20400

11.42

706

712

19500

BHP

RPM

0.4

19800

AIRFLOW
(CFM)

Model No.: PMY 840

FAN PERFORMANCE DATA

SOUND LEVEL DATA


To obtain sound pressure level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM and static efficiency (SE).
SE = (CFM x TSP)/6362 x BHP (See step 4 & table below).
2. Read dBA level from respective graph at operating BHP & SE (%)
3. Knowing RPM, select proper row from sound power factor table and dBA level to each values in row to obtain sound
power level (dB re 10-12).
4. Calculate TSP (Total Static Pressure) as follows:
TSP = ISP + ESP
ESP (External Static Pressure) from Job Specification.
ISP (Internal Static Pressure) Calculate from table below.
FACE VELOCITY
(FPM)

INTERNAL STATIC PRESSURE (inch wg.)


3 ROW

4 ROW

5 ROW

300

0.62

0.70

0.74

400

0.98

1.10

1.14

500

1.25

1.37

1.50

600

1.51

1.61

1.87

Notes:
1) If you have additional section such as bag filter, drip eliminator, etc., add internal losses as shown in the static
pressure drop table.
2) Pressure drop across filter, coil and blower are included in ISP.

31

SOUND LEVEL DATA


PMY 240/300/480/540/600

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

255-443 RPM

3.5

+4

+ 12.5

+8

+ 4.5

+ 1.5

7.5

443-887 RPM

+ 3.5

+9

+ 10

+4

+1

2.5

887-1750 RPM

+ 3.5

+ 8.5

+7

+7

+ 0.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite to the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
32

SOUND LEVEL DATA


PMY 360/420/720/840

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

267-507 RPM

+ 4.5

+ 12.5

+ 7.5

+ 4.5

+ 1.5

7.5

507-1014 RPM

3.5

+ 3.5

+9

+ 10

+4

+ 0.5

2.5

1014-2000 RPM

+ 3.5

+ 8.5

+7

+ 6.5

+ 0.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite to the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
33

STATIC PRESSURE DROP (inch wg.)


FOR OPTIONAL MODULES
COMPONENT

PRESSURE DROP

BAG FILTER

0.5

DRIP ELIMINATOR

0.13

NOTE: Add the above pressure drop values based on the optional
items chosen.

AVERAGE BLOWER MOTOR EFFICIENCY


MOTOR

EFFICIENCY (%)

7.5 HP

0.855

10 HP

0.865

15 HP

0.910

20 HP

0.917

25 HP

0.917

NOTE: Convert BHP to watts using following formula


746 x BHP
Watts =
Motor Efficiency

34

UNIT DIMENSIONS
CONDENSER AIR IN

MODEL No.: PMY 240/300

SIDE F/A

50"

99.75"
12.50"

12"
F2'

F1'

F3'

22.13"

CONTROL BOX (HINGED DOOR)

ELEC. POWER SUPPLY 3" OPENING (BOTH SIDE)

MTG. HOLES 0.625 (3 Nos. EACH SIDE)

1"FPT DRAIN COUPLING (BOTH SIDE)

HEATER BOX (OPTIONAL)

DRIP ELIMINATOR (OPTIONAL)

32.19"

72"

R/A OPENING TOP

F1

F2

22"
CONDENSER AIR IN
CONDENSER SECTION

F3

19.125"

MIXING BOX WITH


FILTER SECTION

COIL SECTION

BLOWER SECTION

TOP VIEW
(NO OBSTRUCTION)

TOP S/A
5

32.19"

19.13"

R/A OPENING

22.13"

3.75"

46"

FRONT S/A

8"

53"

61"
(1549mm)

27"

46"

TOP R/A

F/A OPENING
(EITHER SIDE)

CONDENSER AIR OUT

F2

67"

1.5" [TYP]

5.75"

83.5"
86.5"
(2197mm)

149.75"
(3804mm)

F3

67"

11.75"

F1

END VIEW

FRONT VIEW

MODEL No.: PMY 360/420


CONDENSER AIR IN

SIDE F/A

80"

107.75"
F2'

12.5"

12"

F4'

72"

R/A OPENING TOP

F3'

22.78"

F1'

4"

31.95"

25"

F1

F2
CONDENSER AIR IN

MIXING BOX WITH


FILTER SECTION

CONDENSER SECTION

F4

F3

22"

COIL SECTION

CONTROL BOX (HINGED DOOR)

ELEC. POWER SUPPLY 3" OPENING (BOTH SIDE)

MTG. HOLES 0.625 (4 Nos. EACH SIDE)

1"FPT DRAIN COUPLING (BOTH SIDE)

HEATER BOX (OPTIONAL)

DRIP ELIMINATOR (OPTIONAL)

BLOWER SECTION

TOP VIEW
CONDENSER AIR OUT

TOP R/A
5

F/A OPENING
(EITHER SIDE)

46"

R/A OPENING

3.75"

53"

F1

F3

F2
57"

58"
3

F4
57"

5.75"

187.75"
(4769mm)

FRONT VIEW
Notes:

1. All dimensions are in inches unless otherwise noted.


2. Service clearance should be 1200mm (4 feet) on all sides.
3. F1, F1', F2, F2'.... are mounting hole locations. Please refer to page 38 for weight distribution.
4. Add 27" to overall unit length for bag filter or low velocity filter section.

35

1.5 [TYP]

83.5"
86.5"
(2197mm)

3.75"

8"

61"
(1549mm)

25"

22.78"

46'

31.95"

27"

UNIT DIMENSIONS
MODEL No.: PMY 480/540/600
CONDENSER AIR IN

TOP F/A

94"
F1'

18"

F2'

151.75"

15"

F4'

F3'

F5'

CONTROL BOX (HINGED DOOR)

ELEC. POWER SUPPLY 3" OPENING (BOTH SIDE)

MTG. HOLES 0.625 (5 Nos. EACH SIDE)

1"FPT DRAIN COUPLING (BOTH SIDE)

HEATER BOX (OPTIONAL)

DRIP ELIMINATOR (OPTIONAL)


ARRANGEMENT

66"

R/A OPENING TOP

B
D

9"
F3

F2

F1

F4

F5

34"

CONDENSER AIR IN

MIXING BOX WITH


FILTER SECTION

CONDENSER SECTION

BLOWER SECTION

COIL SECTION

TOP VIEW
CONDENSER AIR OUT

TOP
DISCHARGE

FRONT
DISCHARGE

S/A OPENING
W/O HEATERS
AxB

19.125x22.125

19.125x22.125

S/A OPENING
WITH HEATERS
HxK

61.125x19.125

DIMENSIONS

16.875

16.875

12.688

12.688

TOP R/A

61.125x19.125

30.125
-

18.125

3.75"

46"

K
F/A OPENING
(EITHER SIDE)
46"

8"

61"
(1549mm)
53"

R/A OPENING

42"

F3

F4

F5

3"

F2

F1

4
2

57.5"

57.5"

1.5" [TYP]

57.5"

245.75"
(6242mm)

57.5"

83.5"
86.5"
(2197mm)

5.75"

FRONT VIEW

MODEL No.: PMY 720

CONTROL BOX (HINGED DOOR)

ELEC. POWER SUPPLY 3" OPENING (BOTH SIDE)

MTG. HOLES 0.625 (6 Nos. EACH SIDE)

1"FPT DRAIN COUPLING (BOTH SIDE)

HEATER BOX (OPTIONAL)

DRIP ELIMINATOR (OPTIONAL)


ARRANGEMENT
DIMENSIONS
S/A OPENING
W/O HEATERS
AxB
S/A OPENING
WITH HEATERS
HxK

1. All dimensions are in inches unless otherwise noted.


2. Service clearance should be 1200mm (4 feet) on all sides.
3. F1, F1', F2, F2'.... are mounting hole locations. Please refer to page 38 for weight distribution.
4. Add 27" (37" for PMY720) to overall unit length for bag filter or low velocity filter section.

36

25x22.75

FRONT
DISCHARGE
25x22.75

62x25

62x25

12.375

12.375

22.59

14.45

Notes:

TOP
DISCHARGE

UNIT DIMENSIONS
MODEL No.: PMY 840

CONTROL BOX (HINGED DOOR)

ELEC. POWER SUPPLY 3" OPENING (BOTH SIDE)

MTG. HOLES 0.625 (6 Nos. EACH SIDE)

1"FPT DRAIN COUPLING (BOTH SIDE)

HEATER BOX (OPTIONAL)

DRIP ELIMINATOR (OPTIONAL)


ARRANGEMENT
DIMENSIONS
S/A OPENING
W/O HEATERS
AxB
S/A OPENING
WITH HEATERS
HxK

1. All dimensions are in inches unless otherwise noted.


2. Service clearance should be 1200mm (4 feet) on all sides.
3. F1, F1', F2, F2'.... are mounting hole locations. Please refer to page 38 for weight distribution.
4. Add 37" to overall unit length for bag filter or low velocity filter section.

37

FRONT
DISCHARGE

25x22.75

25x22.75

62x25

62x25

12.375

12.375

22.59

14.45

Notes:

TOP
DISCHARGE

RIGGING INSTRUCTIONS
ATTENTION TO RIGGERS
Hook rigging sling thru holes in base rail, as shown below.
Holes in base rail are centered around the unit center of gravity.
Use spreader bar when rigging, to prevent the slings from damaging the unit.
CAUTION
All panels should be in place when rigging.
Care must be taken to avoid damage to the coils during handling.

LIFT

LIFT
SPREADER BAR

PROPER CLEARANCE
TO BE PROVIDED

MUST BE 3" NOMINAL PIPE THROUGH UNIT FOR


SLINGS TO AVOID BASE DAMAGE

WEIGHT DISTRIBUTION
MODEL
NUMBER

LOAD DISTRIBUTION AT POINTS - KG

F1
F1'
F2
F2'
F3
F3'
233*
233*
243*
243*
199
199
255*
255*
246*
246*
199
199
260*
260*
235*
235*
210*
210*
275*
275*
245*
245*
210*
210*
250*
250*
250*
250*
240*
240*
275*
275*
275*
275*
245*
245*
295*
295*
295*
295*
257*
257*
300*
300*
300*
300*
270*
270*
325*
325*
325*
325*
290*
290*
*Multiply by 1.3 for copper fins coil and add to the total load.
PMY 240
PMY 300
PMY 360
PMY 420
PMY 480
PMY 540
PMY 600
PMY 720
PMY 840

+
F1'

+
F2'

+
F3'

F4
N.A.
N.A.
195
195
204*
217*
228*
214*
230*

F4'
N.A.
N.A.
195
195
204*
217*
228*
214*
230*

+
F4'

F5
N.A
N.A.
N.A.
N.A.
205
213
225
210*
230*

F5'
N.A.
N.A.
N.A.
N.A.
205
213
225
210*
230*

F6
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
231
250

+
F5'

+
F6'

F5
+

F6
+

F6'
N.A
N.A
N.A.
N.A.
N.A.
N.A.
N.A.
231
250

TOTAL
LOAD
(KG)
1350
1400
1800
1850
2300
2450
2600
3050
3300

MODULAR PACKAGED UNIT

F1
+

F2
+

F3
+

F4
+

NOTE: Please refer to the dimensional drawings (page 35-37) for distance between points/mounting holes.

38

TYPICAL SCHEMATIC WIRING DIAGRAM


(Single compressor units)
HVTB
L1

TO FUSED
DISCONNECT
SWITCH OR CB

L2
L3

(SEE NOTE-4)
NTB
(NEUTRAL WIRE)
(SEE NOTE -8)

PLEASE REFER TO
SHEET 2 OF 2 FOR
CONDENSER FAN MOTOR
POWER CONNECTIONS.

LUG

L1

L2

L3

UVM-1 8

COMP
1

BM

UVM
TO NTB
N

TO HVTB
L1

TO ATB
1

70

L3

BMC
OLR

69

L2

CC1
OLR1

T3A

L1

T1A

UVM CONNECTION (OPTIONAL)

T2A

FROM ATB 2

68

REFER TO UNIT
NAMEPLATE FOR
POWER SUPPLY

(REMOVE JP1)

1A

ATB
JP1

ATB

F1

JP2

1A

1B
HC2

30

PLEASE REFER TO FAN MOTOR


CONTROL CONNECTION, (SHEET 2 of 2)

AFS
28

HC1

29

NC

(SEE NOTE 6)

NO

BMC

14

OLR-1

19

PDS1

SEE VFC CONNECTION

(SEE NOTE 6)

(AT RIGHT)

TO ATB

TO
FR1

SWITCHING CONTACTS
FROM T'STAT CONTROLLER OR DDC

3A

4A

12

41A

CC1

LIVE

LED FAULT INDICATOR


LOCK2

COMP1

P1

SQMBO4 ( P III )

SYSTEM1

24Vac

Y1

Y1

Y2

ECB

LOCK1

SYSTEM2

COMP2

P2

INFAN

HEATER1

HEATER2

X1

X2

OUTFAN1

NEUTRAL

OUTFAN2

(by others)

LVTB ( NOTE 7)
R

W1

W1

W2

W2

BM CONTROL

STG1 COOLING

Y1

STG1 HEATING

W1

STG2 HEATING

W2

PRI

ON/OFF

FUSE

(ON/OFF)

TRANS

P3_##

240v
12v-0-12v

HP1

21A

(HP1)

27A

OLR1-1
24A

(SSPS1)
(OPS1)
JP3 25A JP5 26A

HPS1
P

HP2

SEC

ON

(HP2)

DIP

DIP SWITCH
LED
POWER INDICATOR

J_PROG

LP1

22A

(LP1)

23A

LPS1
P

LP2
(LP2)

COMP. WITH CB CONNECTION (OPTIONAL)

55
360 15

190 10

290 15

ECB DIP SWITCH SETTINGS & LED INDICATORS

DIP SWITCH #
ON
OFF

S1

S2

S3

S4

note:
Set dip switch #3 according to unit's option
(pump down or no pump down)

ON= TEST MODE ENABLE

ON= WITH PUMP DOWN OPTION


ON= DUAL COMP
LED INDICATORS
Green power on/off indicator
system lock-out due to system fault
Red
system 1 fault diagnostic
Yellow
blinking slow - LPS1 ckt fault
blinking fast - HPS1 ckt fault
system 2 fault diagnostic
Orange
(not applicable)
(not applicable)

T3A

ON= COMPRESSOR 1 LEAD

T2A

OFF=TEST MODE DISABLE


LOAD BALANCE
S2
OFF= (Comp1&2 Auto Lead Lag)
S3
OFF= WITHOUT PUMP DOWN
S4
OFF= SINGLE COMP.
FACTORY SETTINGS OF DIP SWITCHES

T1A

S1

CB1

COMP
1

CB

L3C

65
450 10

FCS1

L2C

HPS1

CC1

BMC

OLR1

OLR
70

LPS5

TO HVTB
L1 L2 L3

L1C

50 5
45

BM. WITH CB CONNECTION (OPTIONAL)

69

25 5
55

L2A

LPS1
LPS3

TO HVTB
L1 L2 L3

L3A

CLOSE (PSIG)

L1A

OPEN (PSIG)

68

PRESSURE SWITCH SETTINGS


NAME

BM

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items.
2. Refer to unit control box (inside panel) for exact wiring diagram.

39

TYPICAL SCHEMATIC WIRING DIAGRAM


(Single compressor units)
HEATER CONNECTIONS DETAILS (OPTIONAL)
CONN. A
TO HVTB

TO HVTB

TO HVTB

TO 3PH POWER SUPPLY


T2

TO 3PH POWER SUPPLY

T3

T1

T2

OHT

OHT

OHT

OHT

FL

FL

FL

FL
FL

TYPE-I

73B

72B

71B

CB12

73A

71A

72A

CB11

73B

72B

71B

CB12

73A

72A

71A

CB11

T3

L3

L1

L2

L3

L1

L2

L3

L1

T1

L2

LEGEND

(SEE NOTE 6)
HEATER BOX CONNECTION TYPES

CONN. B

TYPE-I I
HEATER DATA TABLE

(Stg. 1 Heating)

HEATER1

(Stg. 2 Heating)

HEATER2

(Stg. 1 Heating)

HVTB
L1 L2 L3

HVTB
L1 L2 L3

T3I

T2I

5KW
7.5KW

5KW
7.5KW

20

10KW

10KW

25

12.5KW

12.5KW

30
40

A
B

15KW
10KW+10KW

15KW
10KW+10KW

50

12.5KW+12.5KW

12.5KW+12.5KW

60

15KW+15KW

15KW+15KW

SSPS1

PMY 240~300

M1/11

M2/14

L1/MP/L

L2/R/N

2-FAN MOTOR LAYOUT

CONTROL
PANEL

CB6

STAGE2

A
A

COMP. 1:
24A

(SEE NOTE 3)

CONTROL
PANEL

2-FAN MOTOR LAYOUT

STAGE1

10
15

COMP. SSPS CONNECTION (AS APPLICABLE)

WITH FAN CYCLING


PMY 240~300

HEATER4

(Stg. 2 Heating)

CONDENSER FAN MOTOR POWER & CONTROL CONNECTION


STANDARD

TOTAL KW CONN.

T1I

T3H

T1H

HEATER3

T2H

T3G

T1G

T3F

T2F

T1F

T3H

T2H

T1H

HEATER2

HEATER1

HC2

T2G

HC1

HC2

T3F

T2F

T1F

HC1

25A
2

(REMOVE JP3)

CRANKCASE HTR CONNECTION (AS APPLICABLE)

CB6

FM1

TO ECB
OUTFAN 1

37B

101
36B

35B

FM1

TO ECB
OUTFAN 1

C.HTR1

100A

L1

COMP. 1:

L2

C.HTR1

OIL PRESSURE SWITCH CONN. (AS APPLICABLE)

FM2

COMP 1

FMC1

12

OPS1

28A

CC1A-1A

240

FCS1

FMC2

CC1A-1B

B. SCROLL COMP.

FMC2

FMC1

12

102

100

102

101

FM2

37A

35A

36A

FMC1

37B

36B

FMC2
35B

37A

36A

35A

FMC1

100

102

101

100

101

102

100

A. SEMI-HERMETIC RECIP. COMP. (BITZER)


COMP. 1:

25A

13

FCS2

26A

OPS1-1

FMC2

(REMOVE JP5)

COMPRESSOR UNLOADER CONNECTION (OPTIONAL)

FM2
T.O.P
NOTE:

13

12B

13B

TO ATB
28A

COMP 1

28A

FMC2

LPS3

NO

LPS5

NC

UNIT ON/OFF
AR1
AR1-1A
UNIT ON

UNIT OFF
FR1-1A

UNIT TRIP

TO ECB
X1

41A

FR1

FR1-2B

56

57

58

49

BM ON
51

BM TRIP

40

BMCA-1B

50

BM OFF
OLR-2

DIP SWITCH (IN ECB)

SSPS

SOLID STATE PROTECTIVE SYSTEM

TOP

FM THERMAL OVERLOAD PROTECTION

UL

COMP. UNLOADER SOLENOID

T'STAT THERMOSTAT
UNDER VOLTAGE MONITOR
FIELD WIRING

NOTES

IF POWER IS OFF 6 HOURS OR MORE,


CRANKCASE HEATER MUST BE ON FOR 12
HOURS BEFORE OPERATING THE SYSTEM.

5. COMPRESSOR IS PROVIDED WITH EITHER SSPS


OR INTERNAL LINE BREAK THERMAL OVERLOAD
PROTECTION.
6. IF PDS OR HEATER IS FACTORY INSTALLED, PLEASE
READ BROKEN LINES AS CONTINUOUS LINES.

BM ON/OFF/TRIP
BMCA-1A

PRESSURE
PUMP DOWN SOLENOID

4. FUSED DISCONNECT SWITCH OR CIRCUIT


BREAKER TO BE PROVIDED BY END USER WITH
RATING AS RECOMMENDED BY ZAMIL.

54

COMP1 ON
COMP1 0FF
COMP1 TRIP

48

OIL PRESSURE SWITCH

P
PDS

FAILURE TO FOLLOW THESE INSTRUCTIONS


MAY RESULT IN COMPRESSOR DAMAGE.

FR1-2A

55

OPS

3. POWER MUST BE SUPPLIED TO CRANKCASE


HEATER FOR MINIMUM OF 12 HOURS PRIOR TO
SYSTEM START UP.

44

INDIVIDUAL COMP. ON/OFF/TRIP


COMP 1

OVER LOAD RELAY

2. ANY WIRE REPLACEMENT SHOULD BE OF THE


900C OR ITS EQUIVALENT.
USE COPPER CONDUCTOR WIRES ONLY.

47

UNIT TRIP
43

NEUTRAL TERMINAL BLOCK

OLR

1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.

2
AR1-1B

46

NTB

SPLICE-CLOSED END

UNIT STATUS (VFC) INDICATION CONNECTION


(OPTIONAL)

45

COMPRESSOR
ELECTRONIC CONTROL BOARD
FUSE
FUSE LINK
FAN CYCLING SWITCH
FAN MOTOR (CONDENSER)
FAN MOTOR CONTACTOR
FAULT RELAY
HEATER CONTACTOR
HIGH PRESSURE SWITCH
HIGH VOLTAGE TERMINAL BLOCK
JUMPER
LINE 1
LINE 2
LINE 3
LOW PRESSURE SWITCH
LUG GROUND

TERMINAL BLOCK OR TERMINATION POINT

NOTE
UL3 CONNECTION APPLICALBLE FOR COMP WITH 3 STEPS
CAPACITY UNLOADING.

COMP/C
ECB
F
FL
FCS
FM
FMC
FR
HC
HPS
HVTB
JP
L1
L2
L3
LPS
LUG

___

UL3

6A
P

AIR HANDLING UNIT


AIR FLOW SWITCH
AUXILIARY RELAY
AUXILIARY TERMINAL BLOCK
BLOWER MOTOR
BLOWER MOTOR CONTACTOR
COMPRESSOR CONTACTOR
CC AUXILIARY CONTACT
CIRCUIT BREAKER
CRANKCASE HEATER

UVM

NO

FM CONTROL CONNECTION APPLICABLE ONLY FOR MOTOR WITH BUILT-IN THERMAL CONTACT (T.O.P)
FOR OVERLOAD PROTECTION.

UL1

5A
NC

CC1A-2B

12

FMC1

CC1A-2A

FM1
T.O.P

AHU
AFS
AR
ATB
BM
BMC
CC
CCA
CB
C. HTR

52

7. USE SHIELDED TYPE CABLE, #18 AWG (MIN.)


FOR LVTB FIELD WIRING. GROUND CONNECT
AT BOTH ENDS.
8. NEUTRAL LINE REQUIRED ON 380V-3Ph-60Hz
POWER SUPPLY ONLY.

TYPICAL SCHEMATIC WIRING DIAGRAM


(Dual compressor units)
HVTB
L1

TO FUSED
DISCONNECT
SWITCH OR CB

L2
L3

(SEE NOTE-4)

PLEASE REFER TO
SHEET 2 OF 2 FOR
CONDENSER FAN MOTOR
POWER CONNECTIONS.

NTB
NEUTRAL
(SEE NOTE -9)

70

68

69

OLR

T3B

BMC

OLR2

T2B

CC2

OLR1

T1B

CC1

T3A

T2A

T1A

LUG

UVM CONNECTION (OPTIONAL)


L2

L1

L1
1

L2

L3

COMP
1

L3

COMP
2

BM

UVM

UVM-1 8

TO ATB

TO HVTB
L1

TO NTB
N

(REMOVE JP1)

1A

ATB
1

JP1

ATB

F1

JP2

1A

1B
HC2

30

AFS
28

HC1

29

NC

(SEE NOTE-6)

NO

BMC

14
PLEASE REFER TO FAN MOTOR
CONTROL CONNECTION, (SHEET 2 of 2)

OLR-1

19

PDS2
PDS1

SEE VFC CONNECTION

(SEE NOTE6)

(AT RIGHT)

TO ATB

TO
FR2

TO
FR1

CC2

3B

3A

COMP2

COMP1

4A

41A
X1

4B

41B
X2

12

13

CC1
( NOTE 8)
SWITCHING CONTACTS
FROM T'STAT CONTROLLER OR DDC

P1

P2

INFAN

HEATER1

HEATER2

OUTFAN1

OUTFAN2

NEUTRAL

(by others)

LVTB ( NOTE 7)
R

24Vac

LIVE

LED FAULT INDICATOR


LOCK2

ECB

LOCK1

SYSTEM2

SQMBO4 ( P III )

SYSTEM1

PRI

FUSE

Y1

Y1

Y2

Y2

W1

W1

W2

W2

(ON/OFF)

P3_##

230v
12v-0-12v

SEC

ON

DIP

DIP SWITCH
LED
POWER INDICATOR

J_PROG

HP1

21A

(HP1)

27A

HP2

21B

(HP2)

27B

LP1

22A

(LP1)

23A

LP2

22B

(LP2)

23B

OLR2-1

TO HVTB

Y2

STG1 HEATING

W1

STG2 HEATING

W2

HPS1

(SSPS2)
(OPS2)
24B JP4 25B JP6 26B

HPS2

(SEE NOTE 6)

TO 3PH POWER SUPPLY


T2

TO 3PH POWER SUPPLY

T3

T1

OHT

FL

T2

OHT

FL

HEATER2
(Stg. 2 Heating)

TYPE-I

73B

72B

71B
HEATER3

HEATER2

(Stg. 1 Heating)

T3I

TOTAL KW CONN.

T2I

T3H

T2H

T1H

T3G

T2G

T1G

HC2

T1I

72A

73A
T3F

T2F

HEATER1

FL
FL

CB12

HC1

T1F

T3H

T2H

HC2

T1H

T3F

(Stg. 1 Heating)

CB11
71A

73B

72B

71B

73A

71A

72A
T2F

HEATER1

T3

OHT

FL
CB12

HC1

LPS2

OHT

CB11

L3

L2

L1

(OPS1)
(SSPS1)
JP3 25A JP5 26A

HEATER BOX CONNECTION TYPES

TO HVTB

L3

L1

L2

STG2 COOLING

LPS1

CONN. B

L3

G
Y1

24A

T1

L1

BM CONTROL
STG1 COOLING

OLR1-1

HEATER CONNECTIONS DETAILS (OPTIONAL)


CONN. A

L2

ON/OFF

TRANS

TO HVTB

T1F

REFER TO UNIT
NAMEPLATE FOR
POWER SUPPLY

HEATER4

(Stg. 2 Heating)

TYPE-I I
HEATER DATA TABLE
STAGE2
STAGE1

10
15

A
A

5KW
7.5KW

5KW
7.5KW

20

10KW

10KW

25

12.5KW

12.5KW

30
40
50

A
B
B

15KW
10KW+10KW
12.5KW+12.5KW

15KW
10KW+10KW
12.5KW+12.5KW

60

15KW+15KW

15KW+15KW

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items.
2. Refer to unit control box (inside panel) for exact wiring diagram.

41

TYPICAL SCHEMATIC WIRING DIAGRAM


(Dual compressor units)
CONDENSER FAN MOTOR POWER & CONTROL CONNECTIONS : STANDARD

12
13
FM1
T.O.P

TO ECB
OUTFAN 2

13
FM1
T.O.P

FM2
T.O.P

FMC2
13

101

CONTROL
PANEL

105

103

101

102

102

**
2

36D

35D
FMC1

13C

FM4
T.O.P

13B

13

**

37B

37C

36B

36C

FM2
T.O.P
2

FM3
T.O.P

12B

12

FMC2

2
FMC2

13

FM1
T.O.P

(SEE NOTE BELOW)

FMC3

13C

12A

FM4
FMC1

12

TO ECB
OUTFAN 2

FM3
T.O.P
2

FM2

TO ECB
OUTFAN 1

FMC2A-1A

FMC1

35C

37A

35A

36A

101

100
35C

37C

36C

37B

36B

FM3

FMC3

FMC1A-1A 12A

FMC2

13B

FM1

FM3

FMC1

12B

12

13B

13

12

TAGNO

FMC3

FM2

TO ECB
OUTFAN 1

FMC1

12B

FM2
T.O.P

35B

36A

35A
2

FMC2

12

102

100

100

101

100
TO ECB
OUTFAN 1
TO ECB
OUTFAN 2

FM1

FMC1

TAGNO

FMC2

37A

37B

36B

35B

FMC1

FM2

(SEE NOTE BELOW)

102

101

100

102

101

100

102

FMC2

37A

36A

35A

FMC1

CB7
104

CB6

CB6

FM1

PMY 480~600
4-FAN MOTOR LAYOUT

CONTROL
PANEL

CONTROL
PANEL

3-FAN MOTOR LAYOUT

CB6

**

HVTB
L1 L2 L3

HVTB
L1 L2 L3

PMY 360~420

HVTB
L1 L2 L3

37D

PMY 240~300
2-FAN MOTOR LAYOUT

35B

HVTB
L1 L2 L3

2
FMC2

13D

(SEE NOTE BELOW)

HVTB
L1 L2 L3

PMY 720

PMY 840

HVTB
L1 L2 L3

6-FAN MOTOR LAYOUT


CONTROL
PANEL

HVTB
L1 L2 L3

5-FAN MOTOR LAYOUT


CONTROL
PANEL

HVTB
L1 L2 L3

CB7
CB7
105

104

103

101

102

100

104

103

105

FMC2

FMC1

TO ECB
OUTFAN 1

12

TO ECB
OUTFAN 2

13

**

FM1
T.O.P

(SEE NOTE BELOW)

FM2
T.O.P

FM3
T.O.P

FM3

TO ECB
OUTFAN 2

13

FM1
T.O.P

(SEE NOTE BELOW)

FM4
T.O.P

13D

FM2
T.O.P

FMC2
2

35F

36D

35D

37B

36B

37D

FM6

2
FMC2

FM5
T.O.P

13C

FM4
T.O.P

13B

13

FM4

FMC1

FM3
T.O.P

12B

12

FMC3

13E

12A

35B
12

FM5
T.O.P

37E

TO ECB
OUTFAN 1

**

FMC1

FM2

FM5

FMC3

FMC2A-1A

13C

36E

35E

37C

36C

35C

35A

37A

FM1

FM5
FMC1A-1A 12A

36A

37E

36E

35E

37D

FMC3

FM4

FMC2

13B

13

36D

FM2
FMC1

12B

12

37B

36B

FM3

35D

35B

37C

36C

FMC2

35C

37A

36A

35A

FMC1

37F

104

105

103

101

102

100

CB6

36F

CB6

13D

FMC1

13E

FM6
T.O.P

2
FMC2

13F

CONDENSER FAN MOTOR POWER & CONTROL CONNECTIONS : WITH FAN CYCLING OPTION
PMY 360~420

HVTB
L1 L2 L3

HVTB
L1 L2 L3

101

13

TO ECB
OUTFAN 2

12A

FCS2

FMC2

FMC2

CONTROL
PANEL

FM1
T.O.P

(SEE NOTE BELOW)

FM2
T.O.P

FM2
T.O.P

FMC2
2

HVTB
L1 L2 L3

13A

105

FMC3

FCS2

12B

12
FM3
T.O.P

13C

12A

**

(SEE NOTE BELOW)

FM2
T.O.P

FMC1
2

13
FM4
T.O.P

FMC3
2

13A

TO ECB
OUTFAN 2

13

13A

FMC2A-1A

FM1
T.O.P

(SEE NOTE BELOW)

12
FM2
T.O.P
13

12B

13B

FM3
T.O.P

FM4
T.O.P

13C

TO ECB
OUTFAN 1
FCS1

13A
13D

13E

FM1
T.O.P

12

FMC3
2

12B
FM3
T.O.P

FMC2
2

12A

35D

37F

36F

FMC2

FM6

FM4

TO ECB
OUTFAN 2

103

105

104

101

100

103
35F

37B

36B

35B

37C

36C

35C
FMC1

13

FMC3

FCS2

P
(SEE NOTE BELOW)

FM5
T.O.P

12A

FMC1

FM2

FM3

12

FCS2

**

FMC1

102

101

FM5

**

FMC2

37E

36E

35E

37A

FM1
FMC3

FMC2

102

100
FM5

36A

35A

37E

36E

FM4
FMC1A-1A 12A FCS1

CB7

FMC1

FMC3

35E

37D

36D

35D

FM2

FMC1

2
FMC4

CONTROL
PANEL

CONTROL
PANEL

104

105

103

101

12

37B

36B

35B

35C

37C

FM3

FM1

TO ECB
OUTFAN 1

13D

FMC2

6-FAN MOTOR LAYOUT

CB6

FMC2

36C

37A

36A

35A

FMC1

FMC4

PMY 840

5-FAN MOTOR LAYOUT

CB7

102

100

CB6

13B

HVTB
L1 L2 L3

HVTB
L1 L2 L3

PMY 720

13A

FM1
T.O.P

(SEE NOTE BELOW)

FMC2

13

12A

37D

35D

37B

FM4

**

FMC3

13C

FMC2

13B

13

HVTB
L1 L2 L3

FM3
T.O.P

FMC1

12B

12

13B

12A

FM1
T.O.P

FMC1

12B

12

FCS1

**

36B

FM2

TO ECB
OUTFAN 2

FMC1

12

FCS2

FMC2A-1A

35B

35C

FM3

TO ECB
OUTFAN 1

P
P

104

103

101

102
37A

36A

35A
FMC3

37C

100

102
37C

36C

35C

FM1

13A

105

TO ECB
OUTFAN 2

13

FM3

FMC1A-1A 12A FCS1

FMC4

37D

12

FM2

FMC1

FMC2

104

FCS1

TO ECB
OUTFAN 1

FMC3

36D

FMC1

CB7

FMC1

FMC3

37B

36B

35B

FM1

12

102

100
FM2

FMC2

37A

35A

36A

FMC1

37B

36B

35B

101

100

102

101

100

101

102

100

101

100

102

FMC2

37A

36A

35A

FMC1

TO ECB
OUTFAN 1

4-FAN MOTOR LAYOUT

CB6

CB6

CB6

FM1

PMY 480~600

HVTB
L1 L2 L3

CONTROL
PANEL

CONTROL
PANEL

3-FAN MOTOR LAYOUT

36D

PMY 240~300
2-FAN MOTOR LAYOUT

36C

HVTB
L1 L2 L3

13A

FMC2
2
FMC4

FM5
T.O.P

13C

13E

FM2
T.O.P

FMC1
2

13

13B

FM4
T.O.P

FMC3
2

13A

FM6
T.O.P

13D

13F

FMC2
2

FMC4
2

** NOTE:

FM CONTROL CONNECTION APPLICABLE ONLY FOR MOTOR WITH THERMAL CONTACT (T.O.P) FOR OVERLOAD PROTECTION.

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items.
2. Refer to unit control box (inside panel) for exact wiring diagram.

42

TYPICAL SCHEMATIC WIRING DIAGRAM


(Dual compressor units)
COMP. WITH CB CONNECTION (OPTIONAL)
TO HVTB
L1 L2 L3

TO HVTB
L1 L2 L3

OIL PRESSURE SWITCH CONN.(AS APPLICABLE)


COMP 1

1
25A

CB1

CB2

L3B

L2B

L1B

L3A

L2A

OPS2

28B

COMP

COMP

26B

OPS2-1

COMPRESSOR UNLOADER CONNECTION (OPTIONAL)


LPS3

TO ATB
28A

COMP 1

28A

5A

28B

NO

5B

UNIT ON/OFF
AR1

1
L3C

L2C

AR1-1A

45

2
AR1-1B

46

UNIT ON

BMC

47

UNIT OFF
UNIT TRIP

OLR

FR1-1A

43

FR2-1A

44A

44

70

69

UL2

UNIT STATUS (VFC) INDICATION CONNECTION


(OPTIONAL)
CB

L1C

NC

TO HVTB
L1 L2 L3

UL1

NC

LPS4
TO ATB
28B

COMP 2

NO

BM WITH CB CONNECTION (OPTIONAL)

68

240

(REMOVE JP6)

T3B

T2B

T1B

CC2
OLR2

T3A

T2A

T1A

25B
CC1

26A

(REMOVE JP5)

COMP 2

OLR1

240

OPS1-1

CC2A-1A
L1A

OPS1

28A

CC1A-1A

UNIT TRIP
INDIVIDUAL COMP. ON/OFF/TRIP

BM

COMP 1

TO ECB
X1

41A

FR1

FR1-2B

L1/MP/L

L2/R/N

COMP. 2:
24B

M1/11

25A

25B
COMP 2

L2/R/N

TO ECB
X2

41B

A. SEMI-HERMETIC RECIP. COMP. (BITZER)

COMP. 2:

CC1A-1B

100A

C.HTR1

60
1

CC2A-1B

101A

C.HTR2

B. SCROLL COMP.
COMP. 1:

COMP. 2:

58

FR2

59

C.HTR1

L2

L2

C.HTR2

L3

BMCA-1A

61

62

BM ON

63

50

BM OFF
OLR-2

51

52

BM TRIP

PRESSURE SWITCH SETTINGS


NAME

NTB

NEUTRAL TERMINAL BLOCK

OLR

OVER LOAD RELAY

OPS

OIL PRESSURE SWITCH

OHT

OVER HEAT THERMOSTAT

PRESSURE

PDS
S

PUMP DOWN SOLENOID


DIP SWITCH (IN ECB)

SSPS

SOLID STATE PROTECTIVE SYSTEM

TOP

FM THERMAL OVERLOAD PROTECTION

UL

COMP. UNLOADER SOLENOID

OPEN (PSIG)

CLOSE (PSIG)

LPS1 & 2
LPS3 & 4

25 5
55

50 5
45

LPS5 & 6

65

55

HPS1 & 2

450 10

360 15

FCS1 & 2

190 10

290 15

ECB DIP SWITCH SETTINGS & LED INDICATORS


S1

ON= TEST MODE ENABLE


OFF=TEST MODE DISABLE
LOAD BALANCE
OFF= (Comp1&2 Auto Lead Lag)
ON= COMPRESSOR 1 LEAD
ON= WITH PUMP DOWN OPTION
S3
OFF= WITHOUT PUMP DOWN
on-board programming function (always set to on)
S4
LED INDICATORS
FACTORY SETTINGS OF DIP SWITCHES
Green power on/off indicator
system lock-out due to system fault
Red
DIP SWITCH # S1 S2 S3 S4
system 1 fault diagnostic
ON
Yellow
blinking slow - LPS1 ckt fault
OFF
blinking fast - HPS1 ckt fault
note:
system 2 fault diagnostic
Set dip switch #3 according to unit's option
Orange
blinking slow - LPS2 ckt fault
(pump down or no pump down)
blinking fast - HPS2 ckt fault
S2

43

UNDER VOLTAGE MONITOR


FIELD WIRING
TERMINAL BLOCK OR TERMINATION POINT

SPLICE-CLOSED END

NOTES

BMCA-1B

49

JUMPER
LINE 1
LINE 2
LINE 3
LOW PRESSURE SWITCH
LUG GROUND

___

COMP2 ON
COMP2 0FF
COMP2 TRIP

48

JP
L1
L2
L3
LPS
LUG

UVM

BM ON/OFF/TRIP

L1

AIR HANDLING UNIT


AIR FLOW SWITCH
AUXILIARY RELAY
AUXILIARY TERMINAL BLOCK
BLOWER MOTOR
BLOWER MOTOR CONTACTOR
COMPRESSOR CONTACTOR
CC AUXILIARY CONTACT
CIRCUIT BREAKER
CRANKCASE HEATER
COMPRESSOR
ELECTRONIC CONTROL BOARD
FUSE
FUSE LINK
FAN CYCLING SWITCH
FAN MOTOR (CONDENSER)
FAN MOTOR CONTACTOR
FAULT RELAY
HEATER CONTACTOR
HIGH PRESSURE SWITCH
HIGH VOLTAGE TERMINAL BLOCK

T'STAT THERMOSTAT

FR2-2B

CRANKCASE HTR CONNECTION(AS APPLICABLE)


COMP. 1:

57

FR2-2A

(REMOVE JP4)

(SEE NOTE 3)

56
COMP1 ON
COMP1 0FF
COMP1 TRIP

(REMOVE JP3)
SSPS2
M2/14

L1/MP/L

55

CC2A-2B

M2/14

CC2A-2A

M1/11

CC1A-2B

SSPS1

CC1A-2A

54

COMP. SSPS CONNECTION(AS APPLICABLE)


COMP. 1:
24A

FR1-2A

LEGEND
AHU
AFS
AR
ATB
BM
BMC
CC
CCA
CB
C. HTR
COMP
ECB
F
FL
FCS
FM
FMC
FR
HC
HPS
HVTB

1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.


2. ANY WIRE REPLACEMENT SHOULD BE OF THE
900C OR ITS EQUIVALENT.
USE COPPER CONDUCTOR WIRES ONLY.
3. POWER MUST BE SUPPLIED TO CRANKCASE
HEATER FOR MINIMUM OF 12 HOURS PRIOR TO
SYSTEM START UP.
IF POWER IS OFF 6 HOURS OR MORE,
CRANKCASE HEATER MUST BE ON FOR 12
HOURS BEFORE OPERATING THE SYSTEM.
FAILURE TO FOLLOW THESE INSTRUCTIONS
MAY RESULT IN COMPRESSOR DAMAGE.
4. FUSED DISCONNECT SWITCH OR CIRCUIT
BREAKER TO BE PROVIDED BY END USER WITH
RATING AS RECOMMENDED BY ZAMIL.
5. COMPRESSORS ARE PROVIDED WITH EITHER
SSPS OR INTERNAL LINE BREAK THERMAL
OVERLOAD PROTECTION.
6. IF PDS OR HEATER IS FACTORY INSTALLED, PLEASE
READ BROKEN LINES AS CONTINUOUS LINES.
7. USE SHIELDED TYPE CABLE, #18 AWG (MIN.)
FOR LVTB FIELD WIRING. GROUND CONNECT
AT BOTH ENDS.
8. COOLING OUTPUT SIGNAL FROM CONTROLLER
SHOULD FOLLOW THE SEQUENCE:
ON SEQUENCE - Y1 FIRST, THEN Y2.
OFF SEQUENCE - Y2 FIRST, THEN Y1.
9. NEUTRAL LINE REQUIRED ON 380V-3Ph-60Hz
POWER SUPPLY ONLY.

INSTALLATION
1. Provide a concrete pad or another form of stand. Use 6-12 each rubber/cork pads 4" x 4" x 1" thick each (rubber-inshear for example) at each corner and along side rails, or use 6-12 each spring isolators.
2. Service Clearance: To avoid condenser air obstructions/recirculation, and to give adequate service space, indicated
clearances must be observed. See drawing below.
3. All wiring must comply with NEC (National Electrical Code) and local electrical codes. The electric supply must
comply with the unit nameplate. See the typical wiring diagram for guidance.
4. All units are pre-charged with R-22 and oil, sealed and tested for leaks. Therefore do not attempt to open the system.
5. Install a flexible connection for duct work to minimize vibration transmission. Connect drain pipe (copper or PVC) to
the nearest drain pit.

RECOMMENDED SERVICE CLEARANCE

E'
CONTROL BOX

CONTROL BOX

S/A

S/A

A = 48
Multiply 'A' by 1.5 if nearby low walls exist.
Multiply 'A' by 2.0 if nearby high walls exist.
FOR MULTIPLE UNIT INSTALLATION, distance between adjacent unit = 2A.
NOTE: There should not be any obstacles above condenser air discharge.

TYPICAL HIGH AND LOW VOLTAGE FIELD WIRING CONNECTIONS

SWITCHING CONTACTS
FROM T'STAT CONTROLLER OR DDC

44

RECOMMENDED SPARE PARTS


PERCENTAGE OF SPARE PARTS
ITEM

ONE YEAR SUPPLY

TWO YEAR SUPPLY

100 UNITS

1000 UNITS

100 UNITS

1000 UNITS

2%

1%

3%

2%

Condenser fan motor

Evaporator blower motor

0.5

Belt

Contactor compressor

Heater contactor

Contactor fan motors

HPS/LPS/other controls

Expansion valve

0.5

Filter drier

Electric heater

0.5

Fuse link, heater

Propeller fan

0.5

Blower wheel

0.5

0.25

0.5

Bearing-blower

Thermostat

Crankcase heater

Filter

Compressor

NOTE : When ordering spare parts, please quote the complete model number on the unit nameplate.

45

PARTS LIST
MODEL NUMBER

PMY240H

PMY240M

PMY240F

PMY300H

PMY300M

PMY300F

PMY360H

PMY360M

PMY360F

COMPRESSOR, SCROLL

800-698-36

800-698-37

800-698-38

800-698-17

800-698-18

800-698-19

800-674-70

800-674-71

800-674-72

CONTACTOR, SCROLL

800-098-65

800-098-61

800-098-59

800-098-65

800-098-61

800-098-59

800-098-65

800-098-63

800-098-61

COMPRESSOR, Semi-hermetic

800-677-13

800-677-14

800-677-15

800-690-10

800-690-11

800-690-12

800-690-04

800-690-05

800-690-06

CAPACITY UNLOADER KITS

800-577-00

800-577-00

800-577-00

800-577-02

800-577-02

800-577-02

800-577-02

800-577-02

800-577-02

CONTACTOR, Semi-hermetic

800-098-68

800-098-63

800-098-61

800-098-68

800-098-65

800-098-63

800-098-67

800-098-63

800-098-61

CONDENSER FAN MOTOR

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

CONTACTOR, FAN MOTOR

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

CONDENSER (30") FAN GUARD

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

CONDENSER FAN

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

MOTOR MOUNT

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

FILTER DRYER

800-531-05

800-531-05

800-531-05

800-531-05

800-531-05

800-531-05

800-531-05

800-531-05

800-531-05

SIGHT GLASS

800-200-00

800-200-00

800-200-00

800-200-00

800-200-00

800-200-00

800-200-00

800-200-00

800-200-00

HIGH PRESSURE CONTROL

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

LOW PRESSURE CONTROL

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

EXPANSION VALVE

800-185-00 (Scroll)
800-184-81 (S.H.)

800-185-00 (Scroll)
800-184-81 (S.H.)

800-185-00 (Scroll)
800-184-81 (S.H.)

800-184-79 (Scroll)
800-184-82 (S.H.)

800-184-79 (Scroll)
800-184-82 (S.H.)

800-184-79 (Scroll)
800-184-82 (S.H.)

800-184-79

800-184-79

800-184-79

OPTIONAL ITEM
PUMP DOWN SOLENOID VALVE

800-705-20

800-705-20

800-705-20

800-705-20

800-705-20

800-705-20

800-705-20

800-705-20

800-705-20

ADJ. HIGH PRESSURE SWITCH

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

ADJ. LOW PRESSURE SWITCH

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

MODEL NUMBER

PMY420H

PMY420M

PMY420F

PMY480H

PMY480M

PMY480F

PMY540H

PMY540M

PMY540F

800-674-82

800-674-83

800-674-84

800-093-41

800-098-65

800-098-63

800-093-41
800-097-54

COMPRESSOR, SCROLL
CONTACTOR, SCROLL
COMPRESSOR, Semi-hermetic

800-674-70 & 82 800-674-71 & 83 800-674-72 & 84


800-098-65
800-093-41

800-098-63 & 65 800-098-61 & 63

800-674-82 & 85 800-674-83 & 86 800-674-84 & 87


800-098-65 & 67 800-098-63 & 65

800-690-07

800-690-08

800-690-09

800-677-13

800-677-14

800-677-15

800-690-10

800-690-11

800-690-12

CAPACITY UNLOADER KITS

800-577-02

800-577-02

800-577-02

800-577-00

800-577-00

800-577-00

800-577-02

800-577-02

800-577-02

CONTACTOR, Semi-hermetic

800-098-67

800-098-63

800-098-61

800-098-68

800-098-63

800-098-61

800-098-68

800-098-65

800-098-63

CONDENSER FAN MOTOR

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

CONTACTOR, FAN MOTOR

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

CONDENSER (30") FAN GUARD

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

CONDENSER FAN

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

MOTOR MOUNT

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

FILTER DRYER

800-531-03

800-531-03

800-531-03

800-531-03

800-531-03

800-531-03

800-531-00

800-531-00

800-531-00

SIGHT GLASS

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

HIGH PRESSURE CONTROL

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

LOW PRESSURE CONTROL

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

EXPANSION VALVE

800-184-81

800-184-81

800-184-81

800-184-81

800-184-81

800-184-81 800-184-81 & 82 800-184-81 & 82 800-184-81 & 82

PUMP DOWN SOLENOID VALVE

800-705-21

800-705-21

800-705-21

800-705-21

800-705-21

800-705-21

800-705-21

ADJ. HIGH PRESSURE SWITCH

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

ADJ. LOW PRESSURE SWITCH

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

OPTIONAL ITEM

46

800-705-21

800-705-21

PARTS LIST
MODEL NUMBER

PMY600H

PMY600M

PMY600F

PMY720H

PMY720M

PMY720F

PMY840H

PMY840M

PMY840F

COMPRESSOR, SCROLL

800-674-85

800-674-86

800-674-87

NIL

NIL

NIL

NIL

NIL

NIL

CONTACTOR, SCROLL

800-097-54

800-098-67

800-098-65

NIL

NIL

NIL

NIL

NIL

NIL

COMPRESSOR, Semi-hermetic

800-690-22

800-690-23

800-690-24

800-677-25

800-677-26

800-677-27

800-690-25

800-690-26

800-690-27

CAPACITY UNLOADER KITS

800-577-02

800-577-02

800-577-02

800-577-00

800-577-00

800-577-00

800-577-02

800-577-02

800-577-02

800-098-65 800-098-65 & 65 800-098-67

800-098-65

800-093-41
800-098-63

800-098-68

800-098-67

800-555-06

800-555-06

800-555-06

800-555-06

800-555-06

CONTACTOR, Semi-hermetic
CONDENSER FAN MOTOR

800-098-67 & 61 800-098-65


800-555-06

800-555-06

800-555-06

800-555-06

CONTACTOR, FAN MOTOR

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

800-098-51

CONDENSER (30") FAN GUARD

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

800-625-38

CONDENSER FAN

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

800-224-28

MOTOR MOUNT

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

800-154-20

FILTER DRYER

800-531-00

800-531-00

800-531-00

800-531-01

800-531-01

800-531-01

800-531-01

800-531-01

800-531-01

SIGHT GLASS

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

800-200-01

HIGH PRESSURE CONTROL

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

800-558-00

LOW PRESSURE CONTROL

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

800-557-00

EXPANSION VALVE

800-184-82

800-184-82

800-184-82

800-184-82

800-184-82

800-184-82

800-187-34

800-187-34

800-187-34

OPTIONAL ITEM
PUMP DOWN SOLENOID VALVE

800-705-21

800-705-21

800-705-21

800-705-08

800-705-08

800-705-08

800-705-08

800-705-08

800-705-08

ADJ. HIGH PRESSURE SWITCH

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

800-557-30

ADJ. LOW PRESSURE SWITCH

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

800-557-29

PARTS LIST: HEATER GROUP


KILOWATTS
7.5

10

15

20

25

30

40

VOLTAGE (V-Ph-Hz)

CONTACTOR

HEATER

208/230-3-60

800-098-51

800-320-03

460-3-60

800-098-51

800-320-23

380-3-60

800-098-51

800-320-13

208/230-3-60

800-098-51

800-320-04

460-3-60

800-098-51

800-320-24

380-3-60

800-098-51

800-320-14

208/230-3-60

800-098-51

800-320-06

460-3-60

800-098-51

800-320-26

380-3-60

800-098-51

800-320-16

208/230-3-60

800-098-55

460-3-60

800-098-51

380-3-60

800-098-51

208/230-3-60

800-098-57

800-320-05 (12.5 kW)

460-3-60

800-098-51

800-320-25 (12.5 kW)

380-3-60

800-098-51

800-320-15 (12.5 kW)

208/230-3-60

800-098-57

460-3-60

800-098-51

380-3-60

800-098-55

208/230-3-60

800-098-55

460-3-60

800-098-55

380-3-60

800-098-57

208/230-3-60

800-098-57

50

460-3-60

800-098-57

380-3-60

800-098-57

60

208/230-3-60
460-3-60
380-3-60

800-098-57
800-098-59
800-098-57

47

PARTS LIST: BLOWER MOTOR GROUP


ODP MOTORS (STANDARD)
HP

7.5

10

15

20

25

VOLTAGE (V-Ph-Hz)

MOTOR

CONTACTOR

OVERLOAD RELAY

208/230-3-60

800-544-73

800-098-59

800-098-91

460-3-60

800-544-73

800-098-55

800-098-88

380-3-60

800-544-65

800-098-55

800-098-89

208/230-3-60

800-544-74

800-098-61

800-098-91

460-3-60

800-544-74

800-098-57

800-098-89

380-3-60

800-544-66

800-098-57

800-098-89

208/230-3-60

800-544-75

800-098-63

800-098-93

460-3-60

800-544-75

800-098-59

800-098-91

380-3-60

800-544-67

800-098-59

800-098-91

208/230-3-60

800-775-00

800-098-67

800-098-94

460-3-60

800-775-00

800-098-61

800-098-91

380-3-60

800-783-40

800-098-63

800-098-93

208/230-3-60

800-776-07

800-098-68

800-098-95

460-3-60

800-776-07

800-098-63

800-098-93

380-3-60

800-783-52

800-098-65

800-098-93

VOLTAGE (V-Ph-Hz)

MOTOR

CONTACTOR

OVERLOAD RELAY

208/230-3-60

800-772-19

800-098-59

800-098-91

460-3-60

800-772-19

800-098-55

800-098-88

TEFC MOTORS (OPTIONAL)


HP

7.5

10

15

20

25

380-3-60

800-876-09

800-098-55

800-098-89

208/230-3-60

800-773-19

800-098-61

800-098-91

460-3-60

800-773-19

800-098-57

800-098-89

380-3-60

800-876-13

800-098-57

800-098-89

208/230-3-60

800-774-19

800-098-63

800-098-93

460-3-60

800-774-19

800-098-59

800-098-91

380-3-60

800-876-17

800-098-59

800-098-91

208/230-3-60

800-775-19

800-098-67

800-098-94

460-3-60

800-775-19

800-098-61

800-098-91

380-3-60

800-876-21

800-098-63

800-098-93

208/230-3-60

800-776-19

800-098-68

800-098-95

460-3-60

800-776-19

800-098-63

800-098-93

380-3-60

800-876-25

800-098-65

800-098-93

48