REGISTER
DESCRIPTION
TYPE
ACCESS
NOTE
100.0-XX
Alarm Records
Structure
Read/Write
1A
101.0-XX
Exception Blocks
Structure
Read/Write
1B
102.0-XX
Structure
Read/Write
1C
103.0
Report Counter
Byte
Read Only
103.1
Byte
Read Only
103.2
Byte
Read Only
103.3
Alarm Reset
Byte
Write Only
103.4
Auto Clear
Byte
Read/Write
103.5
Cry-Out Enable
Byte
Read/Write
103.6
Cry-Out Frequency
Byte
Read/Write
103.7
Cry-Out Now
Byte
Read Only
10
103.8
Ignore DCD
Byte
Read/Write
11
103.9
Byte
Write Only
103.10
Byte
Write Only
12
103.11
Cry-Out Timer
Byte
Read/Write
13
103.12
Log Mode
Byte
Read/Write
103.13
Byte
Read/Write
103.14
Byte
Read/Write
103.15
Alarms Enabled
Byte
Read/Write
103.16
Byte
Read/Write
103.17
Byte
Read/Write
103.18
Byte
Read/Write
103.19
Repote Mode
Byte
Read/Write
15
103.20
Aknowledge all
Byte
Read/Write
16
103.21
Byte
Read
103.22
Byte
Read
103.23
Byte
Read
104.0
Structure
Read Only
Page B8
2103334-001 rev. AA
REGISTER
DESCRIPTION
TYPE
ACCESS
105.0
Structure
Read Only
106.X
Structure
Read Only
107.X
Byte
Read Only
108. X
UInt
Read/Write
109. X
Byte
Read/Write
110. X
Register
Read/Write
111. X
Register
Read/Write
112. X
Register
Read/Write
113. X
Byte
Read/Write
114. X
Register
Read/Write
115. X
Byte
Read/Write
116. X
Byte
Read/Write
117. X
Float
Read/Write
118. X
Byte
Read/Write
119. X
Byte
Read/Write
120.0
UInt32
Read/Write
120.1
UInt32
Read/Write
120.2
UInt32
Read
121. X
String
Read/Write
122. X
Byte
Read Only
123. X
Byte
Read/Write
124.0
UInt
Read Only
124.1
UInt
Read Only
124.2
UInt
Read Only
124.3
UInt
Read Only
125. X
Byte
Read/Write
126. X
Float
Read/Write
127.0
Structure
Read Only
128.0
SInt
Read Only
2103334-001 rev. AA
NOTE
17
Page B9
REGISTER
DESCRIPTION
TYPE
ACCESS
128.1
SInt
Read Only
128.2
SInt
Read Only
128.3
SInt
Read Only
129.0
String
Read Only
129.1
String
Read Only
129.2
String
Read Only
129.3
String
Read Only
129.4
String
Write/Read
130.0
Structure
Read Only
131.X
Uint
Read Only
132.X
Alarm Acknowledge
Byte
Read/Write
18
133.X
Struct
Read Only
19
134.X
Record
Struct
Read/Write
20
135.X
Record
Struct
Read/Write
20
136.X
End of Array
Record
Struct
Read/Write
20
1)
NOTE
14
B.3.1
Alarm System Application Register Notes
These are special structures used by the Totalflow WinCCU/PCCU32 applications.
Currently they can not be accessed via templates or ini files.
A. XX = MAX_ALARMS = 255
B. XX = num_exceptions,user selectable up to 255
C. XX = RAMFLTS = 16
2)
3)
4)
5)
6)
7)
8)
9)
Allows the user to enter floating point numbers as constants that can be used when
building an Alarm Page. The constants can be compared against variables in the device
to generate an alarm.
Number Cry-outs that were not acknowledged by the host..
Number of alarms that have not been sent and/or alarms that have been sent and not
acknowledged by the host.
Number of alarms in the last successful Cry-out. Successful meaning that the Cry-out
was acknowledged by the host.
Reset the number of alarms last reported counter.
Primarily used when polling for alarms or Alarm by Exception, setting to 1 will cause the
alarms to be cleared each time the device is polled for alarms.
Alarm Cry-out is enabled by selecting the port on which alarms will be broadcast.
Selections are: 0 Disabled, 1 - COM1, 2 COM2
The time in minutes between Cry-Outs.
Page B10
2103334-001 rev. AA
B.4
Holding Registers
Format for register list is array#.register#. The Holding Registers application can
be instantiated in any application slot.
REGISTER
DESCRIPTION
TYPE
ACCESS
NOTE
0.0
Programmable
Read/Write
0.1
Programmable
Read/Write
0.2
Programmable
Read/Write
0.(X)
Programmable
Read/Write
1.0
Programmable
Read/Write
1.1
Programmable
Read/Write
1.2
Programmable
Read/Write
1.(X)
Programmable
Read/Write
2.0
Programmable
Read/Write
2.1
Programmable
Read/Write
2.2
Programmable
Read/Write
2.(X)
Programmable
Read/Write
(X).0
Programmable
Read/Write
(X).1
Programmable
Read/Write
2103334-001 rev. AA
Page B11