Вы находитесь на странице: 1из 74

PREPARATION OF BILLS OF QU

USING BESMM 4 AND

BILLS OF QUANTITES DESCRI

BY Mr. AYOOLA I. OGUNKANMI


PUBLIC BUILDING DEPARTMENT
FEDRAL CAPITAL DEVELOPMENT AUTHORITY

GARKI
ABUJA

SUBSTRUCTURE
1.5: EXCAVATING AND FILLING
2.1.1
2.1.2
4.1.1

Removing Trees; (Provisional)


Girth 500 - 1500mm; Filled with laterite
Girth 1500 - 3000mm; Ditto

Nr.
Nr.

Site Clearance; Clearing Site vegetation and other


growth and dispose off site; entire site

Sq.m

5.2.0

Site Preparation; Remove topsoil 150mm deep

Sq.m

6.2.1

Excavation, commencing from stripped level; Foundation


excavation; Not exceeding 2m deep

Cu.m

Extra Over Foundation excavation; (Provisional)


Excavating in; below ground water level

Cu.m

7.1.3
7.2.1

9.1.1
9.2.0

11.1.2

11.2.2

Breaking up; Rock

Cu.m

Disposal
Gound Water; 600mm below original ground level
Excavated material off site

Item
Cu.m

Filling obtained from excavated material


Final thickness of filling not exceeding 500mm deep
500mm thick; Site, not more than 200mm around site,
backfilling foundations; in layers average depth 250mm

Sq.m

Final thickness of filling exceeding 500mm deep


500mm thick; Site, not more than 200mm around site,
backfilling foundations; in layers average depth 250mm

Sq.m

Graded Laterite

12.2.1

Imported Filling; Beds 50mm - 500mm deep 300mm thick;


Level, to falls and cross falls

Cu.m

Granite or other equal and approved Hardcore football size


12.2.1

Imported Filling; Beds 50mm - 500mm deep 300mm thick;


Level, to falls and cross falls

Cu.m

To Collecton

EXCAVATING AND FILLING (Cont'd)


Approved quality 1mm thick damp proof membrane
16.2.1

Damp Proof Membrane; Over 500mm wide, 1mm thick;


Horizontal

Sq.m

1.11: INSITU CONCRETE WORKS


1.1.2/1

2.1.1/1

2.2.2/2

5.1.1/1

Grade 30 Concrete
Mass Concrete; 225mm thick; In trench filling; Poured on or
against earth or unblinded hardcore

Cu.m

Weak Concrete (1:10 - graded sub base)


Horizontal Work; less or equal to 300 thick; in blinding;
poured on or against earth or unblinded hardcore

Cu.m

Grade 25 Concrete
Horizontal Work
Over 300mm thick; In structures; Reinforced less or
equal to 5%.

Cu.m

Vertical Work; less or equal to 300mm thick; in structures;


Reinforced 5%

Cu.m

Formwork

13.1.0
13.2.0

Plain formwork
Sides of foundations and bases;
less or equal to 500mm high: 450mm wide
over 500mm high

Lin.m
Lin.m

14.1.0

Edges of horizontal; less or equal to 500mm high: 150mm

Lin.m

20.1.0

Sides of isolated Columns 188Nr.; Regular rectangular


shape

Sq.m

Reinforcement

34.1.2

High yield steel bars


20mm diameter; Bent;

Tonnes

34.1.2

16mm diameter; Bent;

Tonnes

34.1.2

10mm diameter; Links

Tonnes

37.1.0

Mesh; 4.52kg/sq.m Ref. A152 minimum laps 150mm

Sq.m

To Collection

1.14: MASONRY
Brick/Block Walling
Hollow sandcrete blockwall beded and jointed in
cement and sand (1:6)

1.2.1/1

Walls;
225mm thick; blockwork; skin of hollow walls; laid in
stretcher bond
Cement and Sand (1:1)

Sq.m

16.1.3

Damp Proof Course less or equal 300mm wide; 50mm


thick; Horizontal

Lin.m

1.28: FLOOR WALL CEILING AND ROOF FINISHINGS


Cement and sand (1:4) smooth rendering
7.1.0

Plastering to Walls 12mm thick; Less or equal to 600mm

Lin.m

1.29: DECORATIONS
Dulux or other equal and approved latex paint one coat;
cement floated wall sandpapered smooth and one coat
of primer on floated wall.
1.2.2

Painting to general surfaces; Over 300mm girth; external

To Collection

SUBSTRUCTURE CARRIED TO SUMMARY

FRAMES
1.11: INSITU CONCRETE WORKS
5

Sq.m

Insitu Concrete
Grade 25 Concrete
5.1.1/1

Vertical Work; less or equal to 300mm thick; In structures


Reinforced less or equal to 5%

Cu.m

Formwork
Plain Formwork
20.1.0

Sides of Isolated Columns, 34Nr.; rectangular

Sq.m

Reinforcement

34.1.1*2

High yield steel bars;


20mm diameter; Straight and Bent

Tonnes

34.1.1*2

16mm ditto

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

FRAMES CARRIED TO SUMMARY

UPPER FLOORS
1.11: INSITU CONCRETE WORKS
Insitu Concrete
Grade 25 Concrete

2.1.2/2

2.2.2/2

Horizontal Work;
less or equal to 300mm thick; In structures; Reinforced
less or equal to 5%
Over 300mm thick ditto

Cu.m
Cu.m

Formwork
Plain Formwork
14.1.0

15.1.1

18.1.0

Edges of Horizontal; Width less or equal to 500mm:


150mm wide

Lin.m

Soffits of Horizontal Work;


For concrete less or equal to 300mm thick; Propping
less or equal to 3m high

Sq.m

Sides and soffit of attached Beams; Rectangular

Sq.m

Reinforcement

34.1.1*2

High yield steel bars;


20mm diameter; Straight and Bent

Tonnes

34.1.1*2

16mm ditto

Tonnes

34.1.1*2

12mm ditto

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

UPPER FLOORS CARRIED TO SUMMARY

STAIRCASES
1.11 INSITU CONCRETE WORKS
PLAIN IN SITU CONCRETE REINFORCED
Grade 25 Concrete
2.1.2

4.2.3/2

Horizontal Works; less or equal to 300mm thick


in Structures

Cu.m

Sloping Works over 150 ; over 300mm thick; in


staircases; Reinforced less or equal to 5%

Cu.m

FORMWORK
Plain formwork
14.1.0

Edges of horizontal; less or equal to 500mm high:


150mm wide

Lin.m

Soffits of horizontal works; for concrete less or


equal to 300 thick; propping less or equal to 3m
high

Sq.m

25.1.0

Soffit of sloping work; sloping one way

Sq.m

26.1.0

Staircase strings and the like; maximum width 380mm

Lin.m

27.1.0

Staircase Risers and the like; Vertical 150mm wide

Lin.m

15.1.1

REINFORCEMENT

34.1.1*2

High yield steel bars


16mm diameter straight and bent

Tonnes

34.1.1*2

12mm ditto

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

TO COLLECTION

STAIRCASES (Contd)
1.28: FLOOR WALL CEILING AND ROOF FINISHINGS
Cement and sand (1:4) smooth rendering

7.2.0
7.1.0

Plastering to Walls 12mm thick;


over 600mm wide

Sq.m

Less or equal to 600mm

Lin.m

600 X 600 X 15mm thick Vitrified Tile

2.1.0
2.2.0

Finish to floors, Vitrified Tiles 50mm thick overall


thickness;
less or equal to 600mm wide
Over 600mm wide

Lin.m
Sq.m

11.1.0/1

Finish to Tread; Net width 300mm; Concrete background

Lin.m

12.1.0/1

Finish to Risers; Net width 150mm; Concrete background

Lin.m

Cement and Sand (1:6) screeded beds

1.1.1/2

1.2.1/2

Screeds, beds and toppings, 40mm thick in one coat


less or equal to 600mm wide; Level and to falls only
less or equal to 150 from horizontal; Concrete
background

Lin.m

Over 600mm wide; Ditto

Sq.m

1.29: DECORATIONS
Dulux or other equal and approved latex paint one coat;
cement floated wall sandpapered smooth and one coat
of primer on floated wall.

1.1.1.
1.2.1

Painting to general surfaces;


less or equal to 300mm girth; internal
Over 300mm girth; internal

Lin.m
Sq.m

1.25: STAIRS, WALKWAYS AND BALUSTRADES


Painted mild steel pipe balustrade
7.1.0

Balustrades; 900mm high comprising 20mm diameter


vertical balusters; 40mm diameter sloping handrail; 6Nr.
20mm diameter intermediate rails; vertical balusters
plugged and screwed to concrete with 6mm thick plate
100 X 100mm

Lin.m

To Collections

1.25: STAIRS, WALKWAYS AND BALUSTRADES (Cont'd)


8.1.0

Handrails; 900mm high comprising 20mm diameter


vertical balusters; 40mm diameter sloping handrail; 6Nr.
20mm diameter intermediate rails; vertical balusters
plugged and screwed to concrete with 6mm thick plate
100 X 100mm

10

Lin.m

To Collections

STAIRCASES CARRIED TO SUMARY

11

ROOF CONSTRUCTION AND COVERING


1.11: INSITU CONCRETE WORKS
In situ Concrete
Grade 25 Concrete

2.2.2/2

4.1.2/2

Horizontal Work
Over 300mm thick; In structures; Reinforced less or
equal to 5%
Sloping over 150 ; less or equal to 300mm thick; In
structures; Reinfored less or equal to 5%

Cu.m

Cu.m

Formwork
Plain formwork
17.1.0

Sides and soffit of isolated beams; Rectangular

Sq.m

25.1.0

Soffit of sloping work; Sloping one way; Curved radius


520mm

Sq.m

28.2.0

Sloping top surfaces; over 150; Curved radius 520mm

Sq.m

14.1.0

Edges of horizontal less or equal to 500mm high: 150mm


wide

Lin.m

Reinforcement

34.1.1*2

High Yield reinforcement Bars


12mm diameter; Straight and bent

Tonnes

34.1.1*2

Ditto over 12m long: length m

Tonnes

34.1.1*2

12mm diameter; Curved

Tonnes

34.1.1*2

10mm diameter; Links

Tonnes

12

To Collection

1.16: CARPENTRY
Hardwood pressure impregnated with approved
preservatives

1.1.1
1.1.3

Primary or Structural timbers


50 X 150mm; Rafters and associated timbers

Lin.m

100 X 150mm; Wall Plates

Lin.m

Ditto; Length over 6.00 in one continuous length

Lin.m

50 X 75mm; Purlins

Lin.m

1.1.2/9

Ditto; Length over 6.00 in one continuous length

Lin.m

1.1.5/9

50 X 150mm; Beams; Length over 6.00 in one continuous


length

Lin.m

50 X 100mm; Strutting

Lin.m

1.1.3/9
1.1.2

1.1.8

1.17: SHEET ROOF COVERING


Sheet Metals
0.7 gauge oven baked corrugated coloured Longspan
Aluminium roofing sheet on Zed Purlins
1.2.3

4.1.2/1

Covering over 500mm wide; Sloping 300 Pitch; oven baked


coloured

Sq.m

Boundary work;
200mm girth; Eaves; Horizontal

Lin.m

13

4.1.3/1

350mm girth; Ridges; Horizontal

Lin.m

4.1.5/1

350mm girth; Valleys; Sloping

Lin.m

4.1.6/1

350mm girth; Hips; Sloping

Lin.m

To Collection

1.15: STRUCTURAL METALWORK (Provisional)

1.1.1/4

1.1.2/4
1.2.2/3

1.2.2/2
5.2.1.

6.1.1/1

6.1.2/1

Framed members, framing and fabrication


Length not exceeding 1.00m;
weight less or equal to 25Kg/m; Bracings
Weight 25 - 50Kg/m; Bracings

Tonnes
Tonnes

Lengths 1.00 - 9.00m;


Weight 25 - 50Kg/m; Rafters

Tonnes

Ditto; Beams

Tonnes

Allowance for fittings: Percentage Allowance: 20%; To


framed members
Cold Rolled Purlins, cladding rails and the like:
Zed purlins bolted to 125 X 75 x 8mm 150mm long
angle cleat welded to structural member; 150 X 50 x2mm
Purlins
16mm diameter high tensile steel welded to Purlins:

14

Tonnes

Lin.m

Sag Rods
10.1.1

Lin.m

Holding down assemblies; 6mm thick base plate holding


4Nr. 24mm diameter one side threaded and other end
fish tailed rag bolts complete with nuts and washers
embedded in concrete.

Nr.

Berger paint or other equal and approved


15.3.1/2

Surface Treatment; painting; On site; One primer and


two coats of red oxide

To Collections

INTERNAL AND EXTERNAL WALLS


1.11 INSITU CONCRETE WORKS
In Situ Concrete
Grade 25 Concrete in Superstructures
Plain In Situ Concrete Reinforced
2.1.2/2

Horizontal work; Less or equal to 300mm thick;

15

Sq.m

In structures; Reinforced less or equal to 5%

Cu.m

Formwork - Plain formwork


17.1.0

Sides and soffit of isolated beams; Regular rectangular


shape

Sq.m

Reinforcement
34.1.1*2

High yield steel bars; 12mm diameter; Straight and Bent

Tonnes

34.1.1*2

Ditto; Bars exceeding 12m long

Tonnes

1.14 MASONRY
BRICK/BLOCK WALLING
225mm thick Hollow sandcrete blockwall bedded and
jointed in cement mortar (1:6) and laid in stretcher
bond
1.2.1

1.2.1

Walls overall thickness 225mm; Blockwork; Skin of


hollow walls; laid in wall

Sq.m

Ditto 150mm ditto

Sq.m

INTERNAL AND EXTERNAL WALL CARRIED TO SUMMARY

16

WINDOW
1.23: WINDOWS SCREENS AND LIGHTS
Nigalex or other equal and approved heavy gauge
aluminium section two or three bays with net; factory
glazed with tinted 4mm thick sheet glass complete with
glazing beads and other accessories and ironmongery
including screwing and plugging frames to blockwall
and concretework to Architects drawings

1.1.0/2

Windows and window frames


1200 X 1200mm high

Nr.

1.1.0/2

1500 X 1500mm high

Nr.

1.1.0/2

600 X 600mm high

Nr.

1.26: METAL WORK


Isolated Metal Member
Burglar Bars comprising 50 X 25 X 2mm thick surround;
25 X 25 X 2mm thick vertical bars at 150mm intervals
welded to surround bar and 25 X 25 X 2mm thick
horizontal bars welded to surround bar and vertical
at 300mm intervals including drilling holes in concrete
or blockwork and fixing burglar bars to concrete with
12mm diameter high tensile hold bar driven in concrete
or blockwork complete with painting in red oxide and
finishing in gloss paint

5.1.1/1

Composite Items
Ditto 1200 X 1200mm high; welded on 150mm long 12mm
diameter bar drilled and driven into wall

Nr.

5.1.1/1

Ditto 1500 X 1500mm high; ditto

Nr.

5.1.1/1

Ditto 600 X 600m high; ditto

Nr.

17

WINDOWS CARRIED TO SUMMARY

DOORS
Doors and Frames
44mm thick polished seasoned solid core fluch doors
lipped on all edges with hardwood and faced on both
sides with quality plywood complete with door lining
architraves and all necessary ironmongery

1.1.1
1.1.1

Door Sets
To fit opening size 900 X 2100mm high; blocwall
Ditto 750 X 2100mm high; blockwall

Nr.
Nr.

Purpose made swing doors constructed of hollowsteel


sections and steel plates complete with frames and glazing
comprising of 4mm thick clear sheet glass and beads
including all necessary ironmongery

1.1.1
1.1.1

Door Sets
To fit opening size 1800 X 2100mm high; blockwall
Ditto 1200 X 2100mm high; blockwall

18

Nr.
Nr.

DOORS CARRIED TO SUMMARY

WALL FINISHINGS
1.28: FLOOR WALL CEILING AND ROOF FINISHINGS
Cement and sand (1:4) smooth rendering

7.2.0

Plastering to Walls 12mm thick;


over 600mm wide

Sq.m

7.2.1

Less or equal to 600mm

Lin.m

7.2.0

over 600mm wide externally

Sq.m

7.2.1

Less or equal to 600mm externally

Lin.m

8.2.0

10.2.0
10.1.0
7.2.0

Plastering to isolated columns 12mm thick


over 600mm wide

Sq.m

Plastering to isolated beams 12mm thick


over 600mm wide

Sq.m

Less or equal to 600mm

Lin.m

Tiles to wall 10mm thick; over 600mm wide


1.29: DECORATIONS

19

Sq.m

Dulux or other equal and approved latex paint one coat;


cement floated wall sandpapered smooth and one coat
of primer on floated wall.

1.1.1

Painting to general surfaces;


less or equal to 300mm girth; internal

Lin.m

1.2.1

Over 300mm girth; internal

Sq.m

1.1.2

less or equal to 300mm girth; external

Lin.m

1.2.2

Over 300mm girth; external

Sq.m

WALL FINISHING CARRIED TO SUMMARY

FLOOR FINISHINGS
Cement and Sand screeded bed
1.1.1/1*2 Screeds, beds and topping 40mm thick in one coat;
less or equal to 600mm wide; Level and to falls only
less or equal to 150 from horizontal; Vitrified Tiles
surface; Concrete background
1.2.1/1*2

Lin.m

Over 600mm wide; Level and to falls only less or equal


to 150 from horizontal; Vitrified Tiles surface; concrete
background
600 X 600 X 15mm thick Vitrified Tile
Finish to floors, Vitrified Tiles 50mm thick overall

20

Sq.m

2.1.0
2.2.0
14.1.0/1

thickness;
less or equal to 600mm wide

Lin.m

Over 600mm wide

Sq.m

Skirtings, net height 100mm; 15mm wide; Blockwall


background

Lin.m

300 X 300 X 10mm thick Vitrified Tile

6.1.1.

6.2.1

Finish to floors, Vitrified Tiles 50mm thick overall


thickness;
less or equal to 600mm wide; Level and to falls only
less or equal to 150 from horizontal.
Over 600mm wide; ditto

Lin.m
Sq.m

FLOOR FINISHING CARRIED TO SUMMARY

CEILING FINISHINGS
1.28: FLOOR WALL CEILING AND ROOF FINISHINGS
Cement and Sand (1:4) rendering

21

9.1.0

Finishing to ceiling, plastering 12mm thick; over 600mm


wide

Sq.m

600 X 600 X 20mm thick acoustic mineral fibre suspended


ceiling in aluminium grid bearer
9.1.0

Finishing to ceiling, acoustic ceiling tiles 20mm thick;


over 600wide

Sq.m

Dulux or other equal and approved latex paint one coat;


cement floated wall sandpapered smooth and one coat
of primer on floated wall.
1.2.1.

Painting to general surfaces; Over 300mm girth; internal

CEILING CARRIED TO SUMMARY

22

Sq.m

1.38: MECHANICAL SERVICES


Rainwater Disposal System
Mutunci or other equal and approved uPVC pipe
3.1.1

4.4.2

Pipework; Straight; 100mm diameter uPVC; socket


and spigot joint; fixed to concrete with matching
stainless steel bracket;
Pipe Fittings; 100mm diameter pipe; socket and spigot
joint
Bend

Lin.m

Nr.

4.4.2

450 Bend

Nr.

5.8.1

Shoes

Nr.

5.7.1

Pipe ancillaries; Fulbora or other equal and approve outlet;


uPVC, 100mm diameter, socket and spigot joint.

Nr.

Cold Water Supply System


Rifeng or other equal and approved multi layer pipe
3.1.1/1

4.4.2

Pipework; Straight; 20mm diameter; jointed to


manufacturers instructions; fixed in concrte or blockwork
chases

Lin.m

Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's


instructions
Bends
Nr.

4.5.2

Tees

Nr.

4.2.2

20/12mm bushing

Nr.

5.1.1

Valve

Nr.

5.1.1

Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's


instructions; Angle Valve

23

Nr.

To Collection

MECHANICAL SERVICES (Cont'd)


Cold Water Supply System (Cont'd)
Tigre or other equal and approved uPVC pipe
3.1.1/1

4.4.2

Pipework; Straight; 25mm diameter uPVC; diced and


screwed in joint with cement material and yarn rope;
fixed to duct with matching stainless steel bracket.
Pipe Fittings; 25mm diameter pipe; jointed as before
described
Bend

Lin.m

Nr.

5.1.1

Heavy Gauge Bronze cast Valves

Nr.

4.1.2

Union Connector

Nr.

4.2.2

Nipples

Nr.

Jointing to multi layered pipe

Nr.

Hot Water Supply System


Rifeng or other equal and approved multi layer pipe
3.1.1/1

Pipework; Straight; 20mm diameter; jointed to


manufacturers instructions; fixed in concrte or blockwork
chases

Lin.m

Pipe Fittings; 20mm diameter pipe; jointed to manufacturer's

24

4.4.2

instructions
Bends

Nr.

4.5.2

Tees

Nr.

4.2.2

20/12mm bushing

Nr.

5.1.1

Pipe Fittings; 12mm diameter pipe; jointed to manufacturer's


instructions; Angle Valve

Nr.

To Collection

MECHANICAL SERVICES (Cont'd)


Waste Disposal System
Supply and install the following sanitary fitting
manufactured by Twyford or other equal and approved

2.1.1/1

2.1.1/1

2.1.1/1

Terminal Equipment and fitting


White vitreous China Water Closet Suite comprising
Tank with flushing mechanism; Bowl plugged and
screwed to floor with matching screws including seat
and cover and pan connector.
White Vitreous China Wash Hand Basin complete with
chrome plated waste with chain and black rubber stay
Chrome plated bib tap with hot and cold water discharge
ability and uPVC white bottle trap
White Vitreous enamel coated shower tray with

25

Nr.

Nr.

chrome plated waste and P trap; Chrome plated shower


rose and pipe fixed to wall with clip plugged and
screwed

Nr.

2.1.1/1

Toilet roll Holder plugged and screwed

Nr.

2.1.1/1

900mm long chrome plated towel rail pluigged and


screwed

Nr.

450 X 600 X 10mm thick silver backed mirror

Nr.

2.1.1/1

Ariston or other equal and approved


2.1.1/1

Primary equipment; 50 liter water Heater hanged on wall

Nr.

To Collection

Waste Disposal (Cont'd)


Mutunci or other equal and approved uPVC pipe
3.1.1./1

Pipework; Straight; 100mm diameter uPVC; socket


and spigot joint; fixed to concrete with matching
stainless steel bracket;

26

Lin.m

4.4.2

Pipe Fittings; 100mm diameter pipe; socket and spigot


joint
Bend

Nr.

4.8.2

Reducer Bend

Nr.

4.4.2

450 Bend

Nr.

4.5.2

Tees

Nr.

4.8.2
3.1.1/1

4.4.2

Reducer Tees

Nr.

Pipework; Straight; 50mm diameter uPVC; socket and


spigot joint; fixed to concrete with matching stainless
steel bracket;
Pipe Fittings; 50mm diameter pipe; socket and spigot
joint
Bend

Lin.m

Nr.

4.8.2

450 Bend

Nr.

4.5.2

Tees

Nr.

To Collection

27

Fire Hose Reels


Groundfos or other equal and approved
1.1.1./1

Primary equipment ; Fire fighting system; Fire pumps


Nr.
ABC or other equal and approved fire hose reel

2.1.1/1

Terminal Equipment and Fittings; Swing Arm Fire Hose


Reels; Wall mount Cabinet type in red with 36m X 19mm
fire fighting nozzle; high or low level on floors

Nr.

Heavy Gauge Gavanised iron pipe painted red with gloss


paint
3.1.1/1

4.4.2

Pipework; Straight; 32mm diameter uPVC; diced and


screwed in joint with cement material and yarn rope;
fixed to duct with matching stainless steel bracket.
Pipe Fittings; 32mm diameter pipe; jointed as before
described
Bend

Lin.m

Nr.

4.4.2

450 Bend

Nr.

4.8.2

Reducer Bend

Nr.

4.5.2

Tees

Nr.

5.1.1

Heavy Gauge Bronze cast Valves

Nr.

4.2.2

Union Connector

Nr.

4.2.2

Nipples

Nr.

28

To Collection

MECHANICAL SERVICES (Cont'd)


Air conditioning
Mutunci or other equal and approved uPVC pipe
3.1.1/1

Pipework; Straight; 75mm diameter uPVC; socket


and spigot joint; Laid in chases

Lin.m

Pipe Fittings; 100mm diameter pipe; socket and spigot


joint
4.4.2

450 Bend

Nr.

17.0.0

Testing

Item

18.0.0

Commisioning

Item

21.0.0

Drawing Preparation; Installation, Coordination, as


installed, and record drawings

Item

To Collection

29

ELECTRICAL INSTALLATION
Incoming Services
Merlin Gerin, Schneider or other equal and approved

1.1.1/1

2.1.1/1

2.1.1/1
1.2.0

Primary Equipment
Coloured oven baked metal clad Main Distribution
Panel 800A T,P & N; One incoming 800A Rating; 4Nr
200A outgoing, 3Nr. 60A outgoing and 60A spare
complete with all accessories; Low level in plant room

Nr.

Terminal equipment
Coloured oven baked metal clad Low Voltage
Distribution Panel 200A T P & N; One incoming 200A
Rating; 6Nr. Outgoing and 1Nr. Spare rating 60A
complete with MCCB, 200A T P & N Isolator Switch
and other accessories; Low level on floors

Nr.

Change Over Switch 800A T P & N

Nr.

Offload and position of primary equipment

Nr.

30

1.3.0

Assembly of composite items of prmary equipment

Nr.

Nocaco or other equal and approved

3.1.1/1

Cables
Armoured cable 240sq.mm 4 core copper pvc/swa/pvc
jointed in running length to manufacturer's details;
low level in plant room and on floor
In trenches (Provisional)

Lin.m

3.1.1/1

In sleeves

Lin.m

3.1.1/1

In trunk (Provisional)

Lin.m

3.1.1/1
3.1.1/1

Armoured cable 70sq.mm 4 core copper pvc/swa/pvc


jointed in running length to manufacturer's details;
low level in plant room and on floor
In trenches
In sleeves

Lin.m
Lin.m

To Collection

Incoming Services (Cont'd)

3.1.1/1

Cables (cont'd)
Armoured cable 10sq.mm 4 core copper pvc/swa/pvc
jointed in running length to manufacturer's details;
low level in plant room and on floor
In trenches

Lin.m

3.1.1/1

In sleeves

Lin.m

3.1.1/1

In trunk

Lin.m

Armoured cable 16sq.mm 4 core copper pvc/swa/pvc

31

3.1.1/1

jointed in running length to manufacturer's details;


low level in plant room and on floor
In trenches

Lin.m

3.1.1/1

In sleeves

Lin.m

3.1.1/1

In trunk

Lin.m

AEI Cables Limited or other equal and approved

6.0.1

6.0.1

Cable Terminations and Joints


Outdoor type, 800A 240sq.mm 4 core bronze material
armoured pvc/swa/pvc

Nr.

Outdoor type, 200A 70sq.mm 4 core bronze material


armoured pvc/swa/pvc

Nr.

6.0.1

Indoor type ditto

Nr.

6.0.1

Outdoor type, 60A 10sq.mm 4 core bronze material


armoured pvc/swa/pvc

Nr.

Indoor type, 60A 10sq.mm 4 core bronze material


armoured pvc/swa/pvc

Nr.

Indoor type, 60A 16sq.mm 4 core bronze material


armoured pvc/swa/pvc

Nr.

6.0.1

6.0.1

To Collection

Cable Containment

32

3.0.1/1

3.0.1/1

Galvanised sheet cable trunk with cover rectangular


shape 250 X 75mm thick with three compartments
jointed as may be directed by the Engineer plugged
and screwed to wall; risers

Lin.m

Ditto; low level on floors

Lin.m

Final Circuits
ABB or other equal and approved plugged and screwed
to wall

1.1.1/1

1.1.1/1

Primary Equipment
60A 6 Ways T P & N metal clad Distribution Board
with miniature circuit breakers and 60A ELCB
60A 4 Ways ditto

Nr.
Nr.

Nocaco or other equal and approved single core wire


drawn in 20mm diameter Mutunci or other equal and
approved conduit pipe in chases

7.0.1

Final circuits
PVC copper cable with 10A rating 1.5sq.mm size in
18Nr. Lighting points

Nr.

7.0.1

Ditto 22Nr. Ditto

Nr.

7.0.1

Ditto 11Nr. Ditto

Nr.

7.0.1

Ditto 25Nr. Ditto

Nr.

7.0.1

Ditto 21Nr. Ditto

Nr.

7.0.1

Ditto 17Nr. Ditto

Nr.

7.0.1

Ditto 19Nr. Ditto

Nr.

7.0.1

Ditto 15Nr. Ditto

Nr.

7.0.1

Ditto 14Nr. Ditto

Nr.

7.0.1

Ditto 20Nr. Ditto

Nr.

To Collection

33

Nocaco or other equal and approved single core wire


drawn in 20mm diameter Mutunci or other equal and
approved conduit pipe in chases

7.0.1

Final circuits
PVC copper cable with 30A rating 2.5sq.mm size in
ring circuit
11Nr. 13A Switched socket outlet

Nr.

7.0.1

13Nr. Ditto

Nr.

7.0.1

12Nr. Ditto

Nr.

7.0.1

9Nr. Ditto

Nr.

7.0.1

8Nr. Ditto

Nr.

7.0.1

7Nr. Ditto

Nr.

7.0.1

10Nr. Ditto

Nr.

7.0.1
7.0.1

PVC copper cable with 20A rating 4.0sq.mm size in


1Nr. 15A Switched socket outlet
1Nr. Water Heater

Nr.
Nr.

ABB or other equal and approved accessories

2.1.1

Terminal Equipment
10A One Gang one Way Switch

Nr.

2.1.1

10A One Gang Two Way Switch

Nr.

2.1.1

10A Two Gang one Way Switch

Nr.

2.1.1

10A Two Gang Two Way Switch

Nr.

2.1.1

10A Three Gang one Way Switch

Nr.

34

2.1.1

10A Three Gang Two Way Switch

Nr.

2.1.1

20A Intermediate switch

Nr.

2.1.1

13A switched Socket Outlet

Nr.

2.1.1

13A Twin switched Socket Outlet

Nr.

To Collecton

Scolmore Ltd or other equal and approved Luminaires

2.1.1

Terminal Equipment
1 X 40W Screwneck ceiing mounted Lighting fitting
with diffuser

Nr.

2.1.1

40W Recessed Fitting

Nr.

2.1.1

1 X 36W 1.2m fluorescent fitting with pristmatic


transparent diffuser

Nr.

2.1.1

1 X 100W Bulkhead fitting with transparent diffuser

Nr.

2.1.1

60W Wall mounted lighting fitting with pristmatic


diffuser.

Nr.

2.1.1

15A Socket Outlet

Nr.

2.1.1

SMC or other equal and approved 1200mm sweep


ceiling Fan complete with regulator

Nr.

Fire Alarm system


Gents or other equal and approved

1.1.1/1

Primary Equipment
Vigilon Analogue 3 Loop Addressable Fire Alarm Panel
High level on floors

35

Nr.

Nocaco or other equal and approved single core wire


drawn in 20mm diameter Mutunci or other equal and
approved conduit pipe in chases

7.0.1

Final circuits
PVC copper cable with 10A rating 1.0sq.mm size in
87Nr. Points comprising 51Nr. Optical smoke detector,
18Nr. manual break call bells and 18Nr. Fire alarm call
Bell

Nr.

Gents or other equal and approved

2.1.1
2.1.1
2.1.1

Terminal Equipment
Addressable Optical Smoke Detector
Manual Break Call Bell

Nr.
Nr.

Addressable Fire Alarm Call Bell

Nr.

To Collection

Lightening and Earthing System


Indelec or other equal and approved

12.0.1

12.0.1

12.0.1

Electrodes, Earth Rods Air Terminations, bars


Prevectron 3 S40 Early Steamer Emission Air Terminal
Lightening conductor

Nr.

Chromium plated copper M20 tapered threaded wall


Air Rod lightening arrestor

Nr.

Highly conductive copper coated stainless steel pointed


Copperbound Earth Rod 2400mm deep 17.2mm diameter
in inspection house

Nr.

Indelec Lightening Protection system conductor

36

11.0.1/1

Tapes
Tinned Copper tape conductors 25 X 3mm thick
Roofs

Lin.m

11.0.1/1

Risers

Lin.m

11.0.1/1

Trenches

Lin.m

Nocaco or other equal and approved

5.0.1/1

Cables; 6 sq.mm PVC sheath single core copper cable


low level in floors

Lin.m

5.0.1/1

In trenches

Lin.m

5.0.1/1

In trunks

Lin.m

15.0.0

Testing

Item

16.0.0

Commissioning

Item

19.0.0

Drawing Preparation; Installations, Coordination, as


installed and record drawings

Item

Loose Ancillaries; Keys, tools, spares, chemicals

Item

21.1.0

To Collection

37

QUANTITES

ND

CRIPTIONS

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

Вам также может понравиться