Вы находитесь на странице: 1из 127

RNC Architecture and Interfaces

For public use IPR applies


1
Nokia Siemens Networks

RN33151EN30GLA0

Nokia Siemens Networks


Academy
Legal notice

Intellectual Property Rights


All copyrights and intellectual property rights for Nokia Siemens Networks training
documentation, product documentation and slide presentation material, all of which are forthwith
known as Nokia Siemens Networks training material, are the exclusive property of Nokia
Siemens Networks. Nokia Siemens Networks owns the rights to copying, modification,
translation, adaptation or derivatives including any improvements or developments. Nokia
Siemens Networks has the sole right to copy, distribute, amend, modify, develop, license,
sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals
can use the Nokia Siemens Networks training material for their own personal self-development
only, those same individuals cannot subsequently pass on that same Intellectual Property to
others without the prior written agreement of Nokia Siemens Networks. The Nokia Siemens
Networks training material cannot be used outside of an agreed Nokia Siemens Networks
training session for development of groups without the prior written agreement of Nokia
Siemens Networks.

For public use IPR applies


2
Nokia Siemens Networks

RN33151EN30GLA0

Objectives
After this training module, the student should be able to:
Explain RNC architectures: cabinet, Plug In Unit (PIU) connection, cabling,
Functional Units (FUs), redundancy types and Hardware Management System
(HMS) of RNC196, RNC450 and RNC2600

Explain RU20 RNC configuration and capacity steps for RNC196, RNC450 and
RNC2600

Understand new changes in RU20 (RN5.0) for RNC196, RNC450 and RNC2600

Understand signalling and data flow in RU20 for RNC196, RN450 and RNC2600
Explain changes in RU20 for hardware, software, alarms, MML, measurement

For public use IPR applies


4
Nokia Siemens Networks

RN33151EN30GLA0

UMTS Basic Network Architecture (Rel 7)


CN
VLR
MSS

GERAN
MG
W

Um

BTS
BSC

Nc

PSTN

Nb

MGW

Mc

Mc

PSTN

A
Abis

VL
R

PSTN
PSTN

Nc

GMSS

PSTN
MS
S

BSS

UTRAN

IuCS

Uu
IuCS

Gb

CS-Domain

Gs
EI
R
Gf
Gr

HS
S

IMS
Gc

Go

Iur
Gi

Gn
SIM

IuPS
Iub

Gp

UE
Cu
USIM

For public use IPR applies


5
Nokia Siemens Networks

RNC
Node B

RNS

RN33151EN30GLA0

GGS
N

SGSN
BG

PS-Domain

PDN/
Internet
Other
PLMN

UTRAN Interfaces
Iu-pc
or
ADIF

UTRAN

SAS
or
A-GPS
Server

Uu
WBTS

Iu-BC

CBC

Iu-CS

3GMSC

SRNC

WBTS
Iub

User Equipment
(UE)

Iur

Iu-PS

WBTS
DRNC

3GSGSN

WBTS

Core Network
(CN)

For public use IPR applies


6
Nokia Siemens Networks

RN33151EN30GLA0

Generic Functional Architecture of IPA2800


ATM E1/T1/JT1
1.5-2 Mbit/s

Switching Functions
NIP1
TDM STM-1
155 Mbit/s

IWS1E
IWS1T

Interface Functions

lower traffic
capacity

ATM STM-1
155 Mbit/s

Control Functions
Signal Processing

higher traffic NIS1


MXU
NPS1
capacity
SFU

NIWU

TDM E1/T1/JT1
1.5-2 Mbit/s

IPGO/GE
NPGE

IPFE

A2SU

MXU
DMCU
/TCU
TBU

ISU
/ICSU
Signaling

For public use IPR applies


7
Nokia Siemens Networks

RN33151EN30GLA0

System Functions

OMU

Ethernet
1G (optical/
electric)

Ethernet
100M

SWU

RSMU
/CACU

Resource
mangement

FDU

WDU

Ethernet OMS
10/100 Mbit/s

Generic Block Diagram of IPA2800

STM-1
TDM

IWS1E/T

E1/T1/JT1
ATM
E1/T1/JT
1
TDM

NIP1

IPGO/GE

Ethernet
1G

IPFE

Ethernet
100M

NIS1

STM-1/VC-4
STM-1/VC-3
ATM

NPGE

Ethernet
1G

NPS1

STM-1/VC-4
STM-1/VC-3
ATM

MXU

NIWU

SFU

Ethernet

CU*

A2SU

CU*

CU*

100Base-TX

MXU
CU*

OMS

Ethernet
100Base-TX

SWU

OMU
FDU

For public use IPR applies


8
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU
SPU*

TBU

IPA2800 Conceptual Model

Applications
API

IPA2800
Platform

Application Software (RNC, MGW)


API
API

Signal
Fault Tolerant
Switching
Processing
Computing Platform
Platform
Platform
Software
SW
SW
Modular and Scalable Hardware
(Processing, switching and
interface capacity required)

For public use IPR applies


9
Nokia Siemens Networks

RN33151EN30GLA0

API

Adjunct
Platform
(NEMU)

Mechanics (M2000)
Cabinet mechanics for indoor use
Cabinet contains 4 subracks, 4 fan trays,
and power distribution equipment
EMC shielding at subrack level rather
than at cabinet level
Front and back cabling
Based on metric dimensioning (IEC/ETSI)
Old hardware mechanics (prior to A5):
IC186-B
Indoor Cabinet, 1800*600*600
mm
SRA1 Subrack, ATM, type 1
SRA2 Subrack, ATM, type 2
FTRA Fan Tray
New hardware mechanics (A5HW):
EC216 Equipment Cabinet, 2100*600*600 mm
SRA3 Subrack, ATM, type 3
FTRA-B Fan Tray 1200W
For public use IPR applies
10
Nokia Siemens Networks

RN33151EN30GLA0

Similarities and Differences


of DX200 and IPA2800
(Optional)

For public use IPR applies


11
Nokia Siemens Networks

RN33151EN30GLA0

Comparison of IPA2800 & DX200 Platforms


Similarities and Differences: Hardware Platform
All plug-in units are different in IPA2800 platform and DX 200 platform.
However, plug-in units may contain common hardware blocks in some
cases.
System internal communication: ATM vs. Message Bus and LAPD
channels
Hardware Management System (HMS) replaces Wired Alarms, and
provides new functionality.
Similarities and Differences: Computing Platform
Major improvements visible to application level will be: POSIX, I/O
architecture, System Maintenance, Chorus Computing Platform
Similarities and Differences: Switching Platform
Switching based on ATM: a lot of ATM-specific additional functionality
For public use IPR applies
12
Nokia Siemens Networks

RN33151EN30GLA0

DX 200 / IPA 2800 Platform


Both Platform support the common features:

Distributed Processing Architecture


Modularity
Common Hardware
Modular Software
Fault Tolerance

For public use IPR applies


13
Nokia Siemens Networks

RN33151EN30GLA0

IPA2800 Redundancy Principles

For public use IPR applies


14
Nokia Siemens Networks

RN33151EN30GLA0

2N Redundancy
2N Redundancy (duplication)
one spare unit designated for one active unit
Software in the unit pair is kept synchronized
(hot-standby) -> fast switchover

Active

Hot stand-by

2N redundancy principle

For public use IPR applies


15
Nokia Siemens Networks

RN33151EN30GLA0

Replaceable N+1 Redundancy


Replacement (N+1) or (N+m)
one or more units designated to be spare units for a group
allocating resources to a unit defines it as active, not
allocating resources defines to be spare
spare unit can replace any active unit in the group -> slower
switchover, requires warming (cold-standby)
users responsibility to change the working state of the unit to
reflect the resource allocation situation and to leave at least
one spare unit

Active

Active
Stand-by

N+1 redundancy principle


For public use IPR applies
16
Nokia Siemens Networks

RN33151EN30GLA0

SN+ Redundancy (Load Sharing)


SN+ (Load Sharing)
no spare units, group acts as a resource pool
number of units selected so that there is overcapacity
if a few units are disabled, the whole group can still perform
its functions
Load
50%

Load
33%
Active

Active

Active

Active

33%
33%

SN+ redundancy principle

For public use IPR applies


17
Nokia Siemens Networks

RN33151EN30GLA0

Active

50%
0%

Fail

Functional Unit Redundancy Principles


No redundancy
no special requirements for reliability

No Redundancy is needed in cases where the redundancy of a unit would not


noticeably increase the overall availability performance of the unit type.
For example:
RNC: OMS

BSC: ET
The 2Mbit/s exchange terminal (ET), where the probability of failure of the 2
Mbit/s line is expected to be much greater than that of the exchange terminal
hardware.

For public use IPR applies


18
Nokia Siemens Networks

RN33151EN30GLA0

Multiplex Section Protection (MSP 1+1)


Physical Layer Protection (MSP 1+1)

For public use IPR applies


19
Nokia Siemens Networks

RN33151EN30GLA0

Exercise
1. List 2 Network Elements use IPA2800 Platform
____________________________________

2. Fill in redundancy type to match description


Redundancy Type

Description
If a few units are disabled, the whole group can still
perform its functions
Spare unit can replace any active unit in the group
slower switchover
Software in the unit pair is kept synchronized
Fast switchover

For public use IPR applies


20
Nokia Siemens Networks

RN33151EN30GLA0

RNC Mechanical Design


RNC196
CPD80B Cabinet (H=1800mm)

For public use IPR applies


21
Nokia Siemens Networks

RN33151EN30GLA0

RNC450 and RNC2600


CPD120A Cabinet (H=2100mm)

Connector panels

For public use IPR applies


22
Nokia Siemens Networks

RN33151EN30GLA0

Fan Tray (FTRA-B)


Control and alarm
Interface (rear cable)

Forced cooling for subracks (max power


dissipation per subrack 1,2kW)

2 x 48vdc

M0

M1

FTRA-B is used with 2000mm cabinet

M2

M3

Fans are controlled and supervised by


HMS via fan control and supervision HWB
located in PD30

M4

M5

M6

M7

For public use IPR applies


23
Nokia Siemens Networks

RN33151EN30GLA0

PD30
Plug-in unit

2 x CAN

RNC196 and RNC450 Architecture


The network element consists of
the following parts:

Network interface functions


Switching and multiplexing functions
Control plane functions
User plane functions O&M functions

For public use IPR applies


24
Nokia Siemens Networks

RN33151EN30GLA0

RNC2600 Architecture
Some units from earlier releases
areno longer exist, because
The functionalities are
embedded to other units, or
The unit is no longer supported
The units are:
GTPU, functionalities are
embedded to NPS1(P) and/or
NPGE(P)
A2SU, functionalities are
embedded to NPS1(P)
RRMU, functionalities are
distributed to ICSU and
OMU/RSMU
NIS1(P), replaced with NPS1(P)
NIP1, no more PDH interface
are supported

For public use IPR applies


25
Nokia Siemens Networks

RN33151EN30GLA0

RNC Functional Units in RU20


NIU - NPS1(P)

* Only unit in
RNC196 / RNC450

NIU - NPGE(P)
NIU - NIS1(P)*

NIU - NIP1*

RRMU

SFU

A2SU*

ICSU
MXU
DMCU

MXU

GTPU*
ICSU

RSMU
DMCU
SWU

OMU
TBU

OMS

EHU
HDD
For public use IPR applies
26
Nokia Siemens Networks

WDU

RN33151EN30GLA0

PDU

New Plug-in Units in RNC2600

CDSP-DH

SF20H

MX1G6-A
For public use IPR applies
27
Nokia Siemens Networks

RN33151EN30GLA0

NP2GE-B

NP8S1-B

Block Diagram and Plug-in Unit Variants for


RNC2600
FU/Product
PIU Variant

Standalone

ICSU

CCP18-A

RSMU

CCP18-A

OMU

CCP18-A

DMCU

CDSP-DH

SFU

SF20H

MXU

MX1G6-A

SWU

ESA24

WDU

HDS-B 73G

OMS
(integrated)

MCP18-B

TBUF

TBUF

TSS3

TSS3

PDU

PD30

NPS1

NP8S1-B

NPGE

NP2GE-A

or Integrated

For public use IPR applies


28
Nokia Siemens Networks

RN33151EN30GLA0

Blank Slide for Note page

For public use IPR applies


29
Nokia Siemens Networks

RN33151EN30GLA0

RNC2600 Functional Unit Removed from


Non-exist units Non-exist units

Some units from earlier releases are no longer exist, because


The functionalities are embedded to other units, or
The unit is no longer supported

The units are:


GTPU, functionalities are embedded to NPS1(P) and/or NPGE(P)
A2SU, functionalities are embedded to NPS1(P)
RRMU, functionalities are distributed to ICSU and OMU/RSMU
NIS1(P), replaced with NPS1(P)
NIP1, no more PDH interface are supported

For public use IPR applies


30
Nokia Siemens Networks

RN33151EN30GLA0

Change in RU20 (RN5.0)


for RNC196/RNC450 and RNC2600
Change of RNC196 in RU20 (RN5.0)
Change of RNC450 in RU20 (RN5.0)
Change of RNC2600 in RU20 (RN5.0)

For public use IPR applies


31
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC196
in RU20 (RN5.0)

For public use IPR applies


32
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC196 in RU20 (RN5.0)


Common Iub interface has been removed from RNC functionality

Broadband interfaces has been updated


- Functional unit NPGE or NPGEP offers IP over Ethernet interfaces.
- NPGE or NPGEP is introduced with
RAN1225: IP Interface Upgrade for RNC196 and RNC450

Connectivity rule has been updated


- CBR AAL2 Path VCC: PCR
- UBR+ AAL2 Path VCC: max( 0.1 * PCR, MDCR )

For public use IPR applies


33
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC196 in RU20 (RN5.0)


HSUPA and HSDPA peak rate information has been updated in CDSP-DH
upgrade for HSDPA peak rate per user
The RNC196 HSPA capacity

For public use IPR applies


34
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC196 in RU20 (RN5.0)


Table Capacity and reference call mix model has been updated

NPS1/NPS1P interfaces has been added toRNC196 architecture


RNC196 capacity step 8 information has been added toRNC 196 capacity

New figure RNC configuration and plug-in locations in capacity step 8 has
been added.

For public use IPR applies


35
Nokia Siemens Networks

RN33151EN30GLA0

RNC196 Capacity Steps


Capacity steps:
1. RNC196/48
2. RNC196/85
3. RNC196/122
4. RNC196/159
5. RNC196/196
6. RNC196/300 (RAS05.1)
7. RNC196/450 (RAS05.1)
8. RNC196/1000 (RU20)

Step 6 is achieved by:


Removing NIP1 and FDU.
Replace HDS-A with HDS-B.
Add more ICSU, GTPU, MXU and
A2SU.
Add more NIS1(P).

Step 7 is achieved by upgrade


computer units at step 6 to latest
version.

RNC196, 8 steps
For public use IPR applies
36
Nokia Siemens Networks

RN33151EN30GLA0

RNC 196/1000M in RU20 (RN5.0)


The capacity of RNC196/450M is increased to 1000 Mbit/s (Iub) by removing
some units and replacing them with other functional unit:
SF10 is removed and replaced with SF10E.
NIS1, A2SU are removed and replaced with NPS1.
GTPU is removed and re-configured as ICSU.
Eight more CDSP-DH units are configured.

For public use IPR applies


37
Nokia Siemens Networks

RN33151EN30GLA0

RNC2600 Traffic Flow


GTP termination in NIU

NIU, NPGE(P) or NPS1(P), covers GTPU functionalities in


RNC2600, that is termination of UDP/IP protocol in Iu-PS
interface.
DMPG

NPS1

3G-SGSN

GTP appl.
GTP

GTP

GTP

GTP

UDP

UDP

IP

IP

SNAP

SNAP

LLC

LLC

AAL5

AAL5

AAL5

AAL5

ATM

ATM

ATM

ATM

DMPG

NPGE

3G-SGSN

GTP appl.
GTP

For public use IPR applies


38
Nokia Siemens Networks

GTP

GTP

GTP

UDP

UDP

AAL5

AAL5

IP

IP

ATM

ATM

GE

GE

RN33151EN30GLA0

RNC196 Capacity Figure


RNC196
196/48

196/85

196/122

196/159

196/196

196/300

196/
450

196
/1000

Number of subscribers

59000

122000

181000

240000

300000

300000

360000

1000000

BHCA

52000

108000

160000

216000

272000

272000

320000

1000000

1300

2700

4000

5400

6800

6800

8000

20000

48

85

122

159

196

300

450

1000

Number of carriers

384

576

768

960

1152

1152

1152

1800

Number of BTSs

170

256

340

420

512

512

512

600

AAL2UP connectivity
Mbit/s (AL2S-D)

950

1450

1950

2400

2800

3594

3594

AAL2UP connectivity
Mbit/s (NP8S1B)

5100

RRC connected mode


users

20000

30000

40000

50000

60000

70000

100000

100000

HSDPA on IuPS Mbit/s

43

94

109

140

176

270

405

900

HSUPA on IuPS Mbit/s

13

23

32

42

53

81

122

270

Number of HSDPA
carriers

384

576

768

960

1152

1152

1152

1800

Number of HSDPA BTSs

170

256

340

420

512

512

512

900

Erlangs
Iub throughput Mbit/s

Note: Capacity and reference call mix model


For public use IPR applies
39
Nokia Siemens Networks

RN33151EN30GLA0

RNC196 Interface Capacity


STM-1 / OC-3

E1 / T1

Gigabit Ethernet

RNC196/
Unprotected

Protected

Unprotected

Unprotected

Protected

48

24

16 + 16

64

4+4

85

24

16 + 16

96

10

5+5

122

24

16 + 16

128

12

6+6

156

24

16 + 16

160

14

7+7

196

24

16 + 16

192

16

8+8

300

24

24 + 24

16

16

8+8

450

24

24 + 24

16

16

8+8

1000

24

24 + 24

16

16

8+8

For public use IPR applies


40
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC450
in RU20 (RN5.0)

For public use IPR applies


41
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC450 in RU20 (RN5.0)


Common Iub interface has been removed from RNC functionality

Broadband interfaces has been updated


- Functional unit NPGE or NPGEP offers IP over Ethernet interfaces.
- NPGE or NPGEP is introduced with
RAN1225: IP Interface Upgrade for RNC196 and RNC450

Connectivity rule has been updated


- CBR AAL2 Path VCC: PCR
- UBR+ AAL2 Path VCC: max( 0.1 * PCR, MDCR )

For public use IPR applies


42
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC450 in RU20 (RN5.0)


HSUPA and HSDPA peak rate information has been updated in CDSP-DH
upgrade for HSDPA peak rate per user
The RNC450 HSPA capacity

For public use IPR applies


43
Nokia Siemens Networks

RN33151EN30GLA0

RNC450 Configuration Steps

Configuration steps:
1.RNC450/150
2.RNC450/300
3.RNC450/450

3 basic capacity option


and 6 carrier-optimised option.
1

For public use IPR applies


44
Nokia Siemens Networks

RN33151EN30GLA0

RNC450 Capacity Basic Option


RNC450/150

RNC450/300

RNC450/450

Number of subscriber

181000

284000

360000

BHCA

240000

375000

576000

4000

6250

8000

Iub throughput Mbps

150

300

450

Number of carriers

600

900

1152

Number of BTS

200

300

512

AAL2UP connectivity Mbit/s

1950

2800

3594

RRC connected mode users

35000

70000

100000

HSDPA on IuPS Mbps

135

270

405

HSUPA on IuPS Mbps

41

81

122

Number of HSDPA carries

600

900

1152

Number of HSDPA BTS

200

300

512

Erlangs

Note: Capacities with NSN traffic mix model

For public use IPR applies


45
Nokia Siemens Networks

RN33151EN30GLA0

RNC450 Capacity Figure Carrier Optimised


RNC450/150
Carrier opt1

RNC450/150
Carrier opt2

RNC450/150
Carrier opt3

RNC450/150
Carrier opt4

RNC450/300
Carrier opt

RNC450/450
Carrier opt

Number of subscriber

181000

181000

181000

181000

309000

454000

Busy Hour Call Attempt

240000

240000

240000

240000

408000

720000

4000

4000

4000

4000

6800

10000

Iub throughput Mbps

135

105

80

50

180

250

Number of carriers

660

720

780

840

1200

1800

Number of BTS

220

240

260

280

400

600

AAL2UP connectivity
Mbit/s

1950

1950

1950

1950

2800

3594

RRC connected mode


users

35000

35000

35000

35000

75000

100000

HSDPA on IuPS Mbps

122

95

72

45

163

227

HSUPA on IuPS Mbps

36

28

21

13

49

67

Number of HSDPA
carries

660

720

780

840

1200

1800

Number of HSDPA BTSs

220

240

260

280

400

600

Erlangs

Note: Capacities with NSN traffic mix model


For public use IPR applies
46
Nokia Siemens Networks

RN33151EN30GLA0

RNC450 Interface Capacity

STM-1 / OC-3

E1 / T1

Gigabit Ethernet

RNC450

Unprotected

Protected

Unprotected

Unprotected

Protected

16

8+8
or 12 + 12
(if no E1/T1)

16

4+4

300

24

16 + 16
or 20 + 20
(if no E1/T1)

16

12

6+6

450

24

24 + 24

16

16

8+8

150

For public use IPR applies


47
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC2600
in RU20 (RN5.0)

For public use IPR applies


48
Nokia Siemens Networks

RN33151EN30GLA0

Change of RNC2600 in RU20 (RN5.0)


New standalone OMS in RNC2600 architecture

Number of recommended BTSs has been updated to 1600 BTSs


Values in BHCA calculation have been updated
BHCA = AMR (Erl) / MHT * 3600
MHT used in the formula is 90s according to NSN traffic profile

Capacity related updates throughout RNC2600 capacity

For public use IPR applies


49
Nokia Siemens Networks

RN33151EN30GLA0

RNC2600 Configuration Steps

Configuration steps:
1. RNC2600/step1
2. RNC2600/step2
3. RNC2600/step3
Capacity is licensed

For public use IPR applies


50
Nokia Siemens Networks

RN33151EN30GLA0

Iub PS data throughput (Mbit/s)


AMR capacity (Erl)
Number of carriers

RNC2600 Capacity
RNC2600 step 1

RNC2600 step 2

RNC2600 step 3

Number of subscribers

680 000

1 360 000

2 000 000

BHCA (CS)

680 000

1 360 000

2 000 000

CS Erlangs

17 000

34 000

50 000

CS Erlangs (including softhandover)

23 800

47 600

70 000

800 000

1 400 000

2 000 000

DL Iub throughput Mbit/s

1 100

1 800

2 500

DL + UL Iub throughput Mbit/s

1540

2520

3500

Number of carriers

1 440

2 100

2 800

Number of BTSs

1 440

2 100

2 800

100 000

152 000

200 000

Iu-PS HSDPA net bit rate [Mbit/s]

990

1 980

2 250

Iu-PS HSUPA net bit rate [Mbit/s]

297

594

675

HSDPA carriers

1 440

2 100

2 800

HSDPA BTSs

1 440

2 100

2 800

BHCA (PS)

RRC connected mode subscribers

Note: Capacities and reference call mix model


For public use IPR applies
51
Nokia Siemens Networks

RN33151EN30GLA0

RNC2600 Traffic Flow


DSP pool configuration

RNC2600 use CDSP-DH only


Two powerful DSPs on each DMPG
CCH DSPs process CCH for cells
non-CCH DSPs process R99 DCH and HSPA

DMCU
DMPG

DMPG

PPC

PPC

nonCCH

CCH

nonCCH

DMPG

DMPG

PPC

PPC

nonCCH

For public use IPR applies


52
Nokia Siemens Networks

CCH

RN33151EN30GLA0

nonCCH

nonCCH

nonCCH

RNC2600 Traffic Flow AAL2 switching in NPS1(P)


Old NE

AAL2 VCC

NIS1(P)
or
NIP1

AAL2 VCC
NCID

A2SU

1CID

DMPG

1CID

A2SU

NCID

NIS1(P)
Iu-CS/Iur
-ATM

Iub ATM

RNC2600
AAL2 VCC

Iub ATM

For public use IPR applies


53
Nokia Siemens Networks

NPS1(P)

RN33151EN30GLA0

1CID

1CID

DMPG

AAL2 VCC

NPS1(P)

Iu-CS/Iur
-ATM

RNC2600 Interface Capacity

STM-1 / OC-3

Gigabit Ethernet

RNC2600
Unprotected

Protected

Unprotected

Protected

Step 1

48

24 + 24

16

8+8

Step 2

80

40 + 40

24

12 + 12

Step 3

112

56 + 56

32

16 + 16

For public use IPR applies


54
Nokia Siemens Networks

RN33151EN30GLA0

General Protocol Model


Radio
Network
Layer

Control Plane

User Plane

Application
Protocol

Data
Stream(s)

Transport
Network
Layer

Transport Network
User Plane

Transport Network
Control Plane
ALCAP(s)

Signalling
Bearer(s)

Signalling
Bearer(s)

Physical Layer

For public use IPR applies


55
Nokia Siemens Networks

Transport Network
User Plane

RN33151EN30GLA0

Data
Bearer(s)

Protocols in the CS User Plane

ATM-based
option

Iub

Uu

Iu

CS
application

CS application

RLC

RLC

MAC

MAC
FP
AAL2

WCDMA
L1

PHY

For public use IPR applies


56
Nokia Siemens Networks

UDP

AAL2

IPv4
ATM

Iu-UP protocol

FP
UDP

AAL2

RTP
UDP

WCDMA
L1

UE

Iu-UP protocol

Ethernet-MAC

Ethernet-Phy

WBTS

RN33151EN30GLA0

IPv4
ATM

PHY

AAL2

IPv4

Ethernet-MAC

Ethernet-Phy

ATM

RNC

UDP
IPv4

ATM
Ethernet-MAC

PHY

RTP

Ethernet-Phy

Ethernet-MAC

PHY

Ethernet-Phy

MGW

Protocols in the PS User Plane


Iub

Uu

ATM-based
option

Iu

Gn

PS
application
IP

IP
PDCP

PDCP

GTP-U

GTP-U

GTPU

GTPU

UDP

UDP

RLC

RLC

MAC

MAC

UDP

UDP

FP

IP

IP

FP
AAL2
WCDMA
L1

WCDM
A L1

AAL2

ATM

Ethernet-MAC
Ethernet-Phy

ATM
PHY

WBTS

For public use IPR applies


57
Nokia Siemens Networks

UDP

Ethernet
-MAC

Ethernet-MAC

ATM

Ethernet-Phy

PHY

IP

Ethernet
-MAC

Link
Layer

Link
Layer

Ethernet
-Phy

PHY

PHY

AAL5

AAL5

IPv4

IPv4

PHY

UE

UDP

IP

Ethernet
-Phy

ATM
PHY

RNC

3GSGSN
IP-based
option

RN33151EN30GLA0

PHY

CN GGSN

Protocols in the UE Control Plane


Uu

ATM-based
option

Iub

Iu

NAS

NAS

RRC

RRC

RANAP

RANAP

RLC

RLC

SCCP

SCCP

MAC

MAC

WCDM
A L1

UE

WCDM
A L1

UDP

AAL2

MTP3b

M3UA

SSCF-NNI

SCTP

SSCF-NNI

SCTP

SSCOP

IP

SSCOP

IP

ATM

Ethernet-MAC

PHY

Ethernet-Phy

UDP

AAL5

AAL5

IPv4

IPv4
ATM

Ethernet-MAC

PHY

Ethernet-Phy

WBTS

For public use IPR applies


58
Nokia Siemens Networks

M3UA

FP

FP
AAL2

MTP3b

ATM

ATM

PHY

PHY

AAL5
Ethernet
-MAC

Ethernet
-Phy

RNC

ATM

ATM

PHY

PHY

CN
IP-based
option

RN33151EN30GLA0

AAL5
Ethernet
-MAC

Ethernet
-Phy

Protocols in the Iub and Iur Control Plane


Iub

Iur
NBAP

NBAP

SSCF-UNI

SSCOP

SCTP

IPv4

SSCF-UNI

SSCOP

IPv4

Ethernet-Phy

PHY

RNSAP

SCCP

SCCP

M3UA

SSCF-NNI

SCTP

SSCOP

IPv4

SSCOP

IPv4

AAL5
Ethernet
-MAC

PHY

Ethernet
-Phy

RN33151EN30GLA0

PHY

Ethernet
-Phy

S-RNC
IP-based
option

For public use IPR applies


59
Nokia Siemens Networks

Ethernet
-MAC
ATM

D-RNC

WBTS

M3UA

SCTP

ATM
Ethernet
-Phy

MTP3b

SSCF-NNI

AAL5

ATM

ATM

RNSAP

MTP3b

Ethernet
-MAC

Ethernet
-MAC

PHY

SCTP

AAL5

AAL5

ATM-based
option

User Data and Signalling


Flow in RNC

For public use IPR applies


60
Nokia Siemens Networks

RN33151EN30GLA0

Permanent Signalling Links Traffic Flow

ATM
Iub/Iu/Iur
ICSU

NIU - NPS1(P)

IP
Iub/Iu/Iur

MXU
DMCU
NIU - NPGE(P)

SFU
ICSU
MXU
RSMU
SWU

OMU

OMS

HDD
Standalone or Integrated
For public use IPR applies
61
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU

DMCU

Common Control Channel Traffic Flow

ATM Iub
ICSU

NIU - NPS1(P)
MXU

IP Iub

DMCU
NIU - NPGE(P)

SFU
ICSU
MXU
RSMU
SWU

OMU

OMS

HDD
For public use IPR applies
62
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU

DMCU

Dedicated Control Channel Traffic Flow

ATM Iub
ICSU

NIU - NPS1(P)
MXU

IP Iub

DMCU
NIU - NPGE(P)

SFU
ICSU
MXU
RSMU
SWU

OMU

OMS

HDD
For public use IPR applies
63
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU

DMCU

CS User Data Traffic Flow

ATM Iub
ICSU

NIU - NPS1(P)
MXU

IP Iu-CS

DMCU
NIU - NPGE(P)

SFU
ICSU
MXU
RSMU
SWU

OMU

OMS

HDD
For public use IPR applies
64
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU

DMCU

PS User Data over DCH

ATM Iub
ICSU

NIU - NPS1(P)
MXU

IP Iu-CS

DMCU
NIU - NPGE(P)

SFU
ICSU
MXU
RSMU
SWU

OMU

OMS

HDD
For public use IPR applies
65
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU

DMCU

PS User Data over FACH/RACH

ATM Iub

ICSU

NIU - NPS1(P)
MXU

IP Iu-CS

DMCU
NIU - NPGE(P)

SFU
ICSU
MXU
RSMU
SWU

OMU

OMS

HDD
For public use IPR applies
66
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU
DMCU

HSPA User Data

ATM Iub

ICSU

NIU - NPS1(P)
MXU

IP Iu-CS

DMCU
NIU - NPGE(P)

SFU
ICSU
MXU
RSMU
SWU

OMU

OMS

HDD
For public use IPR applies
67
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU
DMCU

Review of RNC Architecture and Interfaces

UMTS Networks and NSN RNC Overview


RNC2600
RNC196 and RNC450
RNC Protocol and Transport Options
Traffic Flow Examples
Review Questions

For public use IPR applies


68
Nokia Siemens Networks

RN33151EN30GLA0

Review Questions

1. Describe the role of functional units:

RSMU
ICSU
DMCU
OMU
MXU
SFU

2. Explain the difference between NIS1 and NPS1.


3. List all the configuration steps of RNC2600 and the
number of cabinets and subracks equipped with
plug-in units.
For public use IPR applies
69
Nokia Siemens Networks

RN33151EN30GLA0

Review Questions
4. Fill in the missing protocol names in CS domain.
ATM-based IP-based
option
option
CS
applicatio
n

CS application

Iu-UP protocol

MAC
FP
UDP
WCDMA
L1

WCDM
A L1

IPv4
ATM
PHY

UE

Uu

For public use IPR applies


70
Nokia Siemens Networks

IPv4
ATM

Ethernet-MAC

PHY

Ethernet-Phy

WBTS
RN33151EN30GLA0

Iub

AAL2

UDP

Ethernet-MAC

Ethernet-Phy

ATM

IPv4

IPv4

ATM

Ethernet-MAC

PHY

RNC

UDP

PHY

Ethernet-Phy

Iu

Ethernet-MAC
Ethernet-Phy

MGW

Review Questions
5. Draw the flow of PS data over HSPA through the RNC.
Assume that both IP-based Iub and Iu-PS are used.

ICSU

NIU - NPS1(P)
MXU

DMCU
NIU - NPGE(P)

SFU
MXU
RSMU

SWU

OMU

OMS

HDD
For public use IPR applies
71
Nokia Siemens Networks

WDU

RN33151EN30GLA0

MXU

ICSU
DMCU

RNC Functional Units


This is optional module

In case participant has not attend RNC Architecture e-learning or IPA2800 platform
following slides should be cover training

For public use IPR applies


72
Nokia Siemens Networks

RN33151EN30GLA0

RNC Functional Units in RU20


NIU - NPS1(P)

* Only unit in
RNC196 / RNC450

NIU - NPGE(P)
NIU - NIS1(P)*

NIU - NIP1*

RRMU

SFU

A2SU*

ICSU
MXU
DMCU

MXU

GTPU*
ICSU

RSMU
DMCU
SWU

OMU
TBU

OMS

EHU
HDD
For public use IPR applies
73
Nokia Siemens Networks

WDU

RN33151EN30GLA0

PDU

RNC Units Redundancy Type

For public use IPR applies


74
Nokia Siemens Networks

Functional Unit

Redundancy principle

DMCU

SN+

EHU

None

ICSU

N+1

MXU

2N

OMS

None

OMU

2N

RSMU

2N

SFU

2N

TBU

2N

WDU

2N

OMS HDD

2N

NPS1

None

NPGE

None

NPS1P

2N (MSP 1+1 / APS 1+1)

NPGEP

2N

RN33151EN30GLA0

SFU: Switching Fabric Unit (1/2)


Functions:
Serves as the main switch fabric of the exchange.
Provides redundant, fully accessible and non-blocking connection at ATM
level.
Supports both point-to-point and point-to-multipoint connection topologies.
Handles various ATM service categories.
Type:
Redundancy:
Plug-in unit:
Interfaces:

For public use IPR applies


75
Nokia Siemens Networks

Switching Fabric
2N
SF10, SF10E and SF20H
Network Interfaces
Low bit-rate network interface and control computer
(via MXU)
OMU from the unit computer of SFU via MXU

RN33151EN30GLA0

SFU: Switching Fabric Unit (2/2)

SF10
For public use IPR applies
76
Nokia Siemens Networks

SF10E
RN33151EN30GLA0

SF20H

MXU: Multiplexer Unit (1/2)


Functions:
Enable connection of the low-to-medium bit-rate signal processing units
and computer units, as well as low-bit-rate network interface units, to the
ATM switch fabric
Multiplexes/de-multiplexes traffic from tributary units to the ATM switching
fabric vice versa.
ATM layer functions such as header translation, UPC/NPC parameter
control, OAM functions, traffic management.

Type
Redundancy
Plug-in unit

For public use IPR applies


77
Nokia Siemens Networks

: Multiplexer Unit
: 2N
: MX622-B, MX622-C, MX622-D, MX1G6, MX1G6-A

RN33151EN30GLA0

MXU: Multiplexer Unit (2/2)

MX622-B/C/D

For public use IPR applies


78
Nokia Siemens Networks

RN33151EN30GLA0

MX1G6-/A

A2SU: AAL Type 2 Switching Unit (1/2)


Functions:
Performs minipacket switching of AAL2 CPS.
Collects AAL2 layer statistics
This unit is no longer needed when network interface unit NIP1 and/or
NIS1(P) are not used in RNC.
Type
Redundancy
Plug-in unit

For public use IPR applies


79
Nokia Siemens Networks

: Signal Processing Unit


: SN+
: AL2S-B/D

RN33151EN30GLA0

A2SU: AAL Type 2 Switching Unit (2/2)

AL2S-B
For public use IPR applies
80
Nokia Siemens Networks

AL2S-D
RN33151EN30GLA0

OMU: Operational and Management Unit (1/2)


Functions:
Cellular management
Handles all RNC's crucial upper-level system maintenance functions
Serves as an interface between OMS and the other units of the
network element
Maintains radio network configuration and recovery
Houses radio network database and ATM/IP configuration database
Has dedicated storage devices

Basic maintenance
Hardware configuration management
HMS supervision
Centralised recovery functions
Type: Computer unit with a dedicated storage device unit as a sub-unit
Redundancy: 2N
Plug-in unit:
CCP10, CCP18-A
For public use IPR applies
81
Nokia Siemens Networks

RN33151EN30GLA0

OMU: Operational and Management Unit (2/2)

CCP 10
For public use IPR applies
82
Nokia Siemens Networks

CCP18-A

RN33151EN30GLA0

OMU's Storage Device


New plug-in unit HDS-B, consist of
two Hard Disk Drive (HDD): One
for OMU and another for OMS
73 GB formatted storage
capacity/disk
Redundancy type : 2N
External devices: USB memory
stick, one for each OMU (for
CCP18-A only)

For public use IPR applies


83
Nokia Siemens Networks

RN33151EN30GLA0

Configuration and redundancy principle of OMU's


storage devices
The two mutually redundant WDUs
are connected simultaneously to
both OMUs by means of separate
SCSI buses.
SCSI connection is shown on the
figure beside. (CCP18-A and HDSB)

For public use IPR applies


84
Nokia Siemens Networks

RN33151EN30GLA0

ICSU: Interface Control and Signalling Unit (1/2)


Functions:
Handles signalling transaction and RRM functions:
Signalling protocols to Iu, Iub, Iur and Iu-BC interfaces for
NBAP, RNSAP, RANAP, SABP signalling
ALCAP (Q.2630.1) signalling ,RRC signalling
Termination of the UNI-SAAL, NNI-SAAL/MTP-3 and SCTP/M3UA
signalling associations
Monitoring and recovery of the signalling links
Distributed RRM functions
Admission control (AC), Handover control (HC)
Load control (LC) , Packet scheduling (PS)
Location calculations for location-based services
Type
Redundancy
Plug-in unit
For public use IPR applies
85
Nokia Siemens Networks

: Computer Unit with no sub units


: N+1
: CCP10, CCP18-A, CCP18-C
RN33151EN30GLA0

ICSU: Interface Control and Signalling Unit (2/2)

CCP10
For public use IPR applies
86
Nokia Siemens Networks

CCP18-A
RN33151EN30GLA0

CCP18-C

Resource and Switch Management Unit (1/2)


Functions:
Controls the switch fabrics in RNC

Establishes connections for calls according to requests from the signalling


computer units (ICSUs).

Handles DSP resource management.

Allocation of the DSPs and associated computer resources to different tasks, such as
macrodiversity combining and data traffic functions.
supervision and management of the DMCU units, including the necessary software
upload procedures
management of the ATM connections within DMCU

ATM switching management functions:

Establishment of both internal and external connections via the SFU


Management and control of the SFU, A2SU and MXU.
Transmission resource management.

Type
Redundancy
Plug-in unit
For public use IPR applies
87
Nokia Siemens Networks

: Computer Unit
: 2N
: CCP10, CCP18-A, CCP18-C

RN33151EN30GLA0

Resource and Switch Management Unit (2/2)

CCP10
For public use IPR applies
88
Nokia Siemens Networks

CCP18-A
RN33151EN30GLA0

CCP18-C

GTPU: GPRS Tunnelling Protocol Unit (1/2)


Function:
Facilitates RNC connections towards the SGSN by performing those
RNC-specific Iu user plane functions which are related to GTP protocols
Routing based on GTP tunnel ID
UDP/IP (User Datagram Protocol / Internet Protocol) protocols
termination
IP and GTP protocol processing

This unit is no longer needed if Iu-PS interface is implemented using new


network interface unit, NPS1(P) or NPGE(P)
Type
Redundancy
Plug-in unit

For public use IPR applies


89
Nokia Siemens Networks

: Computer Unit with no sub unit


: SN+
: CCP10, CCP18-A, CCP18-C

RN33151EN30GLA0

GTPU: GPRS Tunnelling Protocol Unit (2/2)

CCP10
For public use IPR applies
90
Nokia Siemens Networks

CCP18-A
RN33151EN30GLA0

CCP18-C

DMCU: Data and Macro-Diversity Combining Unit


Purpose:
WCDMA L1 functions, including macro-diversity combining (MDC) and
outer loop power control.
RLC-U and RLC-C protocol processing
MAC-C and MAC-D protocol processing
PDCP (Packet Data Convergence Protocol) protocol processing
GTP termination
Encryption
HSDPA with CDSP-C
Type
Redundancy
Plug-in unit

For public use IPR applies


91
Nokia Siemens Networks

: Signal processing unit with no sub unit


: SN+
: CDSP-C, CDSP-DH

RN33151EN30GLA0

DMCU: Data and Macro-Diversity Combining Unit

CDSP-C
For public use IPR applies
92
Nokia Siemens Networks

RN33151EN30GLA0

CDSP-DH

OMS: Operation & Maintenance Server Unit(1/2)


Purpose:
RNC element management tasks and local user interface
Provides interface toward higher-level network management function,
such as OSS
Provide graphic-based local interface
Processing fault and performance management data
Support for configuration management in RNC
O&M functions which are not handled by other computer units of the RNC
post-processing support for measurement and statistics
peripheral device control
Type
: Computer unit, with dedicated storage devices and the
Ethernet Switch unit as sub-units
Redundancy
: None
Plug-in unit
: MCP18-B
For public use IPR applies
93
Nokia Siemens Networks

RN33151EN30GLA0

OMS: Operation & Maintenance Server Unit (2/2)

MCP18-B
For public use IPR applies
94
Nokia Siemens Networks

RN33151EN30GLA0

OMSs Storage Device

New plug-in unit HDS-B, consist of two Hard


Disk Drive (HDD): One for OMU and another for
OMS

73 GB formatted storage capacity/disk


Redundancy type : 2N

For public use IPR applies


95
Nokia Siemens Networks

RN33151EN30GLA0

Configuration and redundancy principles of OMS


storage devices
OMS has two redundant disk
with RAID0 configuration
SCSI connection is shown on
the figure beside. (MCP18-B
and HDS-B)

For public use IPR applies


96
Nokia Siemens Networks

RN33151EN30GLA0

ESA: Ethernet Switch for ATM 24 Ports


Provides physical LAN/Ethernet
interfaces for connections between
OMS and the other units of the
network element.
The ESA24 upgrade increases
LAN switching capacity.
Redundant ESA24 is needed for
AGPS feature
Type: Sub unit to OMS
Redundancy: None/2N
Capacity/ Performance: 24 physical
10/100 Base-T Ethernet interfaces

For public use IPR applies


97
Nokia Siemens Networks

RN33151EN30GLA0

Standalone OMS
1RU high server that is mountable to a standard 19 inch rack
Concentrates operation and management traffic and performs operation
and management activities towards the RNC and WCDMA Base Stations
under control of NetAct
Local management interface towards RNC network elements with basic
centralised alarm and performance management capabilities
Capable of handling capacity of RNC2600, 1 600 WCDMA BTSs and
4 800 cells
Capable of handling different types of mass management operations
under the control of NetAct

For public use IPR applies


98
Nokia Siemens Networks

RN33151EN30GLA0

Standalone OMS
Benefit:
State-of-the-art feature set
High quality, proven software platform
Scalable, efficient architecture
Accurate status of the network
Local operation interface
Secure software platform
Easy to place and install

OMS HW:
Redundancy:

For public use IPR applies


99
Nokia Siemens Networks

HP ProLiant DL360 G6 1U rack-mount server


None

RN33151EN30GLA0

Standalone OMS Interfaces


RNC OMS connects to RNC through
Nokia Siemens Networks
management interface EMT

All fault management, performance


management, configuration and
software management transactions
to/from RNC OMS are transferred
over the EMT interface

The NWI3 and EMT management


interfaces used in Nokia Siemens
Networks WCDMA systems provide
sophisticated functional capabilities,
reliability and efficiency

For public use IPR applies


100
Nokia Siemens Networks

RN33151EN30GLA0

Network Interface Unit PDH (NIP1)


Provides 16 physical electrical

PDH (E1/T1/JT1) interface


Execute physical and ATM layer
functionalities
Provides ATM header translation,
OAM function and Traffic policing.
Provides an optional reference
clock for timing and
synchronisation
Support Inverse Multiplexing for
ATM (IMA)

Redundancy: None
Plugin unit : NI16P1A

For public use IPR applies


101
Nokia Siemens Networks

RN33151EN30GLA0

Concept of IMA
Low bit rate transmission lines can be combined into a group that
seen as a single virtual link by ATM

IMA sublayer is part of the physical layer.


It is located between the traditional Transmission Convergence
sublayer and the ATM layer.
IMA Group

IMA Group

Physical Link #0
PHY

PHY

Physical Link #1
PHY

PHY

Single ATM Cell Stream


from ATM Layer
Physical Link #2
PHY

Original ATM Cell


Stream to ATM Layer
PHY

IMA Virtual Link

Tx direction: cells distributed across links in round robin sequence


Rx direction: cells recombined into single ATM stream
For public use IPR applies
102
Nokia Siemens Networks

RN33151EN30GLA0

Network Interface Unit SDH (NIS1/NIS1P)


Provides STM-1/OC-3 external

interface
Execute physical and ATM layer
functionalities
Provides ATM header translation,
OAM function and Traffic policing.
Provides an optional reference
clock for timing and
synchronisation, handles bit timing,
line coding, and timing recovery
Support MSP1+1

Redundancy: None/2N
Plugin unit : NI4S1-B

For public use IPR applies


103
Nokia Siemens Networks

RN33151EN30GLA0

Network Interface Unit NPS1(P)


Functions:
Provides 8 SDH STM-1/STM-4 interfaces and an
RJ45 connector, and handles multiprotocol
packet processing at wire speed and network
connectivity
Maps ATM cells to/from transmission frame
structure of SDH/Sonet.
Performs AAL2 minipacket switching.
Translates ATM header.
Performs UPC/NPC, traffic management,
performance management and performance data
collection.
Provides optional reference clock for timing and
synchronisation.

It supports MSP1+1 / APS1+1 for SDH/Sonet


Redundancy type: NONE or 2N
Plugin unit type
NP8S1, NP8S1-A, NP8S1-B (two slots wide)
For public use IPR applies
104
Nokia Siemens Networks

RN33151EN30GLA0

Network Interface Unit NPGE(P)

Functions:
Provides Ethernet interfaces and handles
multiprotocol packet processing at wire speed.
Two 1000Base-LX/T (optical or electrical) Gigabit
Ethernet interfaces and two 10/100 Base-T
(electrical) Fast Ethernet interfaces
Maps IP packet to/from transmission frame
structure of Ethernet.
Translates IP header.
Performs traffic management, performance
management and performance data collection.
Terminates GTP protocol when used at Iu-PS.

Redundancy type: NONE or 2N


Plugin unit type
NP2GE, NP2GE-A, NP2GE-B

For public use IPR applies


105
Nokia Siemens Networks

RN33151EN30GLA0

Power Distribution System (1/2)


Functions:
Distributes the -48 V/-60 V power from the rectifiers or batteries to the
equipment inside the RNC cabinets
Consists of:
Cabinet Power Distributor
Subrack Power Distributor
Subrack power distributor controls the cooling equipment of its own
subrack on the basis of messages sent by the OMU
Redundancy
Units

For public use IPR applies


106
Nokia Siemens Networks

: 2N
: CPD80/120-A
PD20/30

RN33151EN30GLA0

Power Distribution System (2/2)

PD20/30
For public use IPR applies
107
Nokia Siemens Networks

RN33151EN30GLA0

Power distribution principle and redundancy


To ensure 2N redundancy for the power distribution lines, the RNC cabinets
are provided with two independent feeding input branches
Each CPD120-A unit contains:
Connectors for one of the two mutually redundant supply lines from the
batteries/rectifiers. In this way the two independent input branches are
kept separate until the subrack level.
Connectors for four supply lines to the subracks. Each subrack is supplied
by a line from both CPD120-As, giving 2N redundancy.
Circuit breakers for the outgoing supply lines, each with 30-A rating

For public use IPR applies


108
Nokia Siemens Networks

RN33151EN30GLA0

Fuse Connection
1

10 11 12 13 14 15 16 17 18 19

FA4
FA3
FA2
FA1
FB1
FB2
FB3
FB4

38

FA5 and FB5 to fan tray FTRx


For public use IPR applies
109
Nokia Siemens Networks

RN33151EN30GLA0

Timing and Buffering Unit (1/2)


Functions:
Responsible for the network element synchronization, timing signal
distribution and message transfer functions in the hardware management
system
Receives an input timing signal from upper network level, adjusts its local
oscillator to long time mean value and delivers this synchronised timing
signal as system timing to all plug-in units.
Operates in plesiochronous mode, if all synchronisation are lost
Collect alarms from the PIUs in the same subrack and transfer them to
HMS master (OMU)
3 synchronisation inputs from line interface card
8 synchronisation outputs support maximum 8-cabinet configuration
Redundancy:
Plug-in unit:
For public use IPR applies
110
Nokia Siemens Networks

2N
TSS3/A and TBUF

RN33151EN30GLA0

Timing and Buffering Unit (2/2)

TBUF

TSS

For public use IPR applies


111
Nokia Siemens Networks

RN33151EN30GLA0

Network Timing and Synchronisation

PRC

MSC

MSC

PRC

PRC

MGW

RNC

PRC

BS

BS

PRC

PRC

BS

PRC = Primary Reference Clock


For public use IPR applies
112
Nokia Siemens Networks

RN33151EN30GLA0

RNC Timing and Synchronisation

Timing Ref. 1
NPS1(P) 2
Timing Ref. 2
NPS1(P) 3
Timing Ref. 3

Timing
signal to
PIU

TBUF

TSS3

NPS1(P) 4

TSS3

TBUF

ext. Sync
CPSY-A

TBUF

Timing Bus 0

For public use IPR applies


113
Nokia Siemens Networks

RN33151EN30GLA0

CPSY-B

TBUF

Timing Bus 1

Timing
signal to
PIU

Connection principle and redundancy for the


timing and synchronisation distribution bus

For public use IPR applies


114
Nokia Siemens Networks

RN33151EN30GLA0

External Hardware Unit


Functions:
Receive external alarms and send as alarm
message to OMU via HMS bus
Drive the optional External Hardware Alarm
panel (EXAU-A / EXAU), the cabinet
integrated lamp, and possible other external
equipment.
Redundancy: No
Plugin unit: EHAT

EXAU

For public use IPR applies


115
Nokia Siemens Networks

RN33151EN30GLA0

EHAT

RNC Units Summary


Functional Unit
(redundancy)

Supported HW

OMU (2N)

CCP18-A

WDU (2N)

HDS-A or HDS-B, with WDW18, WDW36 or WDW73.

FDU (2N)

MDS-A

OMS (No)

MCP18-B (4GB memory)

HDD (2N)

HDS-A or HDS-B, with WDW73 or WDW147

RSMU (2N)

CCP10, CCP18-A, CCP18-C

ICSU (N+1)

CCP10, CCP18-A, CCP18-C

DMCU (SN+)

CDSP-C (int. D), CDSP-DH

GTPU (SN+)

CCP10, CCP18-A, CCP18-C

A2SU (SN+)

AL2S-D

NIU (No or 2N)

NI16P1-A, NI4S1-B, NP8S1, NP8S1-A, NP8S1-B, NP2GE, NP2GE-A, NP2GE-B

SFU (2N)

SF10, SF10E, SF20H

MXU (2N)

MX622-B, MX622-C, MX622-D, MX1G6, MX1G6-A

SWU (No)

ESA24

TBU (2N)

TSS3, TBUF

EHU (No)

EHAT

PDU (2N)

CPD80, CPD120, PD20, PD30

For public use IPR applies


116
Nokia Siemens Networks

RN33151EN30GLA0

Hardware Management System


Lowest intelligent system
Running on HMS bus, comprises 3
node types:
Master Node, head of HMS
Bridge Node, divide HMS
network into subsystem, which
physically each subrack.
Slave Node, interface toward
PIUs

Function of HMS
Collect equipment data from the
equipped PIUs
Transfer of system initialisation
data
Collect HW fault notification
Control and supervise external
or auxiliary equipments

For public use IPR applies


117
Nokia Siemens Networks

RN33151EN30GLA0

Hardware Management System


HMMN = Hardware
Management Master
Node
HMSB = HMS Bridge
HMSS = HMS Slave

For public use IPR applies


118
Nokia Siemens Networks

RN33151EN30GLA0

Change in RU20
Reference reading material:
Nokia Siemens NetworksWCDMA RAN, rel. RU20,operating documentation
DN70515054: Changes in RU20
DN70357656: Changes in configuration parameters for radio network, ATM transport
plan, and IP transport plan

For public use IPR applies


119
Nokia Siemens Networks

RN33151EN30GLA0

RU20: New MML Programs


Q9

DHCP Server Data Handling


Use this command group to maintain the data on DHCP server.These commands
cover a wide range of maneuvers related to DHCP server: configure and
interrogate DHCP server options, configure, modify and interrogate pool basic
information, bind and unbind pool with unit and network interface,delete IP pool
and interrogate pool binding relationship, add and delete IP address ranges,
manage and interrogate DHCP client IP address status, manage DHCP server
status,manage and interrogate DHCP server log.

UW

Preload Handling
Use the command to start system preloading,cancel system preloading and
interrogating system preloading information

For public use IPR applies


120
Nokia Siemens Networks

RN33151EN30GLA0

RU20 : Modified MML Programs


LJ

Bundle and Endpoint Handling

NE

Signaling Network State Interrogation

Q8

IP Qos Configuration Handling

QM

IP Interface Configuration Handling

QR

TCP/IP Stack Data Handling

US

Working State an Restart Handling

W7

Licence and Feature Handling

WP

Signal Processing Service Handling

WS

Software Package and Status Handling

YA

EXCHANGE TERMINAL CONFIGURATION HANDLING

YB

IMA Group Handling

YG

BFD Supervision Handling

YW

SDH TRANSMISSION PROTECTION HANDLING

For public use IPR applies


121
Nokia Siemens Networks

RN33151EN30GLA0

Differences in the hardware implementation


between RU10 (RN4.0) and RU20 (RN5.0)
New plug-in units
TSS3-A, Timing and Synchronization, SDH, Stratum 3,Variant A
New mechanics
Cable-supporting shelves have been changed from CS186-B to CS216-A in
RNAC cabinet
RNC OMS hardware changes
Operation and Management Server (OMS) has been introduced as a
standalone network element. HP Proliant DL360 Generation 6 hardware
platform is used to support the standalone RNC OMS.

For public use IPR applies


122
Nokia Siemens Networks

RN33151EN30GLA0

RU20 : RNC New Alarms

For public use IPR applies


123
Nokia Siemens Networks

RN33151EN30GLA0

RU20 : RNC Changed Alarms

For public use IPR applies


124
Nokia Siemens Networks

RN33151EN30GLA0

RU20 : RNC Changed Alarms

For public use IPR applies


125
Nokia Siemens Networks

RN33151EN30GLA0

RU20 : RNC Alarm system configuration changes

RU20 : RNC Removed Alarms


There are no removed alarms in RN5.0

For public use IPR applies


126
Nokia Siemens Networks

RN33151EN30GLA0

RU20 : RNC OMS Changed Alarms

For public use IPR applies


127
Nokia Siemens Networks

RN33151EN30GLA0

RU20 : RNC OMS New Alarms

RU20 : RNC OMS Removed Alarms


There are no removed alarms

For public use IPR applies


128
Nokia Siemens Networks

RN33151EN30GLA0

Вам также может понравиться