4-in. OnTrak
The 4-in. OnTrak integrated MWD and
LWD system provides real-time directional
surveys, gamma ray, multiple-propagation
resistivity, annular pressure, drilling dynamics
measurements from a single sub. This
innovative design takes into account all the
challenges present in the most demanding
rotary-steerable and LWD applications for
reliable operations and reduced NPT. Our
proprietary multiple-propagation resistivity
sensor design provides the most accurate
measurements in the industry. The 4-in.
OnTrak service combines an integrated
sensor section with a downhole power and
communications module and the Advantage
surface system to deliver optimal directional
control, accurate formation evaluation, and
information to enable reservoir navigation.
The 4-in. OnTrak service provides the
platform for the AutoTrak rotary steerable
service and advanced LWD services including
LithoTrak, SoundTrak, TesTrak, and
CoPilot.

For reservoir navigation, the 4-in. OnTrak


sensors provide eight multi-depth resistivity
measurements, enabling optimum wellbore
placement. Two gamma ray detectors
mounted on opposite sides of the tool provide
an indication of approaching bed boundaries
and can be used to provide an image of the
wellbore. The annular pressure reading can
be delivered with flow on or off and provides
information for ECD monitoring for timely
reaction to wellbore stability issues. Finally,
drilling dynamics measurements allow the
optimization of drilling parameters on surface
and improve reliability.
The 4-in. OnTrak service includes the
capability of Passive Magnetic Ranging (PMR)
as part of the AccuTrak service for
Advanced Wellbore Positioning (AWBP).
The 4-in. OnTrak service is capable to
provide AccuFit service which includes the
real-time pressure profile from a Formation
Integrity Test or Leak-Off Test to be
transmitted uphole immediately after the test.

Even at high ROPs, superior log quality can


be achieved by combining this service with the
quality borehole provided by the 4-in.
AutoTrak rotary-steerable system.
Features

Benefits

Real-time reservoir navigation

Accurate well placement and increased net


pay

Azimuthal gamma ray measurement

Confirmation of bed boundaries and


orientation

Reliable, 2-way communication between


downhole and surface

Real-time decision making and drilling


optimization

Compact sensor sub

Reduced BHA length and near-bit


measurements

High-frequency phase resistivity

Superior vertical resolution and identification


of thin beds and fluid contacts

Low-frequency attenuation resistivity

Increased depth of investigation and accurate


prediction of Rt with greater immunity to
borehole conditions

Passive Magnetic Ranging

Ranging measurements without the need for


additional equipment.

Flow off annular pressure measurement

Near real-time circulation free accurate


equivalent static density measurement

4-in. OnTrak

Copyright 2015 Baker Hughes Incorporated. All rights reserved.


GM-GLB-OTK-100278 Rev. B

Technical Data S ummary

4-in. OnTrak
General Tool Specifications
Nominal Tool OD
Hole size range
Length total (A)
Length OTK sensor sub (B)
Length BCPM (C)
Stop sub (D)
Weight (including stop sub)
Primary power source
Tool connections top/bottom
Operating Specifications and Limits

US Units

SI Units

4 in.
121 mm
5 in. to 6 in.
146 mm to 171 mm
34.3 ft
10.5 m
20.2 ft
6.2 m
14.1 ft
4.3 m
23 ft
0.60.9 m
2,200 lb
998 kg
Drilling fluid driven turbine
NC38 box / NC38 pin
US Units

SI Units

Flow Rate
Low flow
Normal flow
High flow

gpm
lpm
125 (148)187
475 (560)708
161 (190)251
611 (719)950
216 (255)350
819 (965)1,325
()minimum flow rate for Downlink Operation
Maximum WOB
251 klb
1,120 kN
Maximum tool rotation
400 rpm
Maximum drilling torque (at the bit)
10,300 ft-lb
14 kNm
Maximum torque to failure
20,650 ft-lb
28 kNm
Maximum overpull to failure without
668 klb
2,970 kN
rotation
Maximum operating temperature
347F
175C
Minimum operating temperature
-4F
-20C
Maximum hydrostatic pressure
30,000 psi
2,070 bar
Maximum bit pressure drop
No limitation
1% max. volume, acc. to API 13B
Sand content
(<0.5% recommended)
40 ppb = 114 kg/m (Any pumping of LCM
Maximum LCM
must be carried out according to Baker Hughes
procedures)

Max DLS for Tool Passage for AutoTrak


With rotation
10/100 ft
10/30 m
Without rotation
30/100 ft
30/30 m
Max DLS for tool passage should only be used as a guide. Actual limits may vary
depending on BHA configuration. Please contact Baker Hughes representative for
specific applications.
80% Maximum deviation from mean rpm
(e.g. 100 rpm: rpm range=20180), limited
Maximum rpm variation
by max tool rotation specification, (from
recorded memory or as flagged by
corresponding real-time severity level)
Refer to Supplemental Technical
Maximum axial and lateral vibration
Specification document
TDS-20-60-0000-00
Sensor Specifications
Measure point from bottom of tool
Pressure
Azimuthal gamma ray
MPR
Directional and vibration
Multiple Propagation ResistivityMPR
2 MHz Resistivity
Phase Difference
Range
Accuracy

Drilling Services
2001 Rankin Road
Houston, Texas 77073
Phone: +1 713-625-4200
www.bakerhughes.com

US Units

SI Units

5.1 ft
2.5 ft
9.7 ft
15.7 ft

1.6 m
0.8 m
2.9 m
4.8 m

Sensor Specifications (continuation)


Attenuation
Range
Accuracy
Vertical resolution

US Units

0.1500 ohm-m
2% (0.125 ohm-m)
1 mmho/m (>25 ohm-m)
8 in. (20 cm) for 90% response in
conductive beds

400 kHz Resistivity


Phase Difference
Range

0.11,000 ohm-m
1% (0.125 ohm-m)
1 mmho/m (>25 ohm-m)

Accuracy
Attenuation
Range
Accuracy
Vertical resolution

0.1200 ohm-m
5% (0.110 ohm-m)
5 mmho/m (>10 ohm-m)
12 in. (30 cm) for 90% response in
conductive beds

Azimuthal Gamma Ray


Sensor type
Measurement
Range

Scintillation (x2)
API GR
0500 API
2.5 API@100 API and
ROP=60 ft/hr (18.3 m/hr)
6 in.
6 in.

Accuracy
Vertical resolution
Directional
PMR maximum distance
Sensor type
MTF/GTF switching
Measurement
Range
Inclination
0180
Azimith2,3
0360
Toolface
Magnetic2 TF
0360
Gravity3 TF
0360
Total Magnetic Field
0100,000 nT
Dip Angle2
-9090
Drilling Dynamics and Pressure
Range
Resolution
Accuracy
Vibration
Acceleration range
Frequency range
Real time log option
Post run/memory log options
Rotation and Stick-Slip
Rotation speed
Real-time log options
Post run/memory log options

SI Units

82 ft
25 m
Tri-axial accelerometer
Tri-axial flux gate
Operator selectable (default: 3)
Resolution
Accuracy1
0.09
0.1
0.35
1.0
1.4
1.4
35
0.04

1.5
1.5
100
0.2

030,000 psi
02,070 bar
5 psi
0,35 bar
0.25% of full scale
015 g
082 Hz
Lateral and Axial vibration; transmitted as
severity level (scaled to g-RMS)
Average and maximum lateral and axial
vibration in g-RMS and as severity level
01,000 rpm (1% Accuracy)
Downhole rpm, stick-slip transmitted as
severity level
Min., Max., and average rpm, stick-slip
and backward rotation severity

All sensor accuracies are 2 Sigma confidence


For a typical magnetic field value at 30 latitude
3 Accuracy applies to inclinations greater than 5.0
1

0.13,000 ohm-m
1% (0.1-50 ohm-m)
0.5 mmho/m (>50 ohm-m)

Although the information contained herein is believed to be accurate, no other representations are made concerning the information. Under no circumstances shall Baker Hughes be liable for any incorrect or incomplete
information. All technical specifications and commercial information concerning the product and/or services described herein may be changed at any time without further notice. Refer to Supplemental Technical Specifications
(TDS-20-60-0000-00) for further environmental specific specifications and information on the application, operation, and handling of Baker Hughes tools. Technical Data Summaries are controlled documents and can only be
released through the BHOS Global Ops/AMO Documentation Group.