Вы находитесь на странице: 1из 150

System Circuit integrity

in the event of fire


Safety cables and systems from a professional

Cabling Solutions

Safety cable systems


Halogen-free safety cables
with circuit integrity and system circuit integrity

Halogen-free safety cables


H05Z-K, H07Z-K / U / R
NHXMH, (N)HXM(St)H
N2XH, N2XCH
J-H(St)H
J-H(St)H Fire alarm cable

with reference to VDE


22
26
30
42
44

(N)HXH, (N)HXCH FE180 E30-E60


(N)HXH, (N)HXCH E90
JE-H(St)H / HRH FE 180 E30L / E30-E90
Fire alarm cable FE180 E30-E90
Fibre optic safety cables

from page 64
from page 74
from page 80
from page 84
from page 90

Wire mesh cable trays / accessories


Cable trays / accessories

from page 96
from page 98

Halogen-free safety cables


with circuit integrity
Fire alarm cables Standard/Enhanced
Safety cables FE180

Safety cables

with reference to VDE

from page 46
from page 54

Cable ducts I30, type Hermannkanal


WUM (support measure)

94
95

Fixing devices
100
101
102

Multi cable support E30-E90

103

Distribution boxes E30


Emergency lighting

109
110

Fixing devices

Single clamps, type SAS, SAS V4A


Strap clamps, type B without trough (LW)
Strap clamps, type B with trough (LW)

Support systems

Support systems / Cable ducts

Fire stop systems

Distribution boxes
Cable joints E30/E90
Distribution boxes
Connection/terminal boxes

106
107
108

Accessories
E0 multi-cable supports
Fire protection plugs / accessories
Fire protection screws

111
from page 112
114

Armoured conduits

Distribution boxes

Firestop systems

104
105

from page 115


Accessories

Fire stop systems, plates


Fire stop systems, plugs/accessories

121
122
123

Information

Information
Colour codes in accordance
with VDE, CENELEC and SEV standards
E30-E90 support systems
Compendium of standards

Datwyler
A reliable partner at your side

Convincing every time, everywhere


The life blood of a modern public or commercial building is the
functionality and reliability of the system solutions for communications,
building automation, power supply, safety and lifts. This is true of any
such construction, irrespective of whether it is an office block, hotel,
sports stadium, television studio or a tunnel. Choose a reliable system
partner right from the start.

Hotels, hospitals

Office blocks

Parliament buildings, universities

Shopping centres

Data centres

Tunnels

Datwyler

Choose Datwyler!
Datwyler is a highly regarded company about to celebrate its 100th year of
operation. With the backing of a financially powerful group, Datwyler operates on the international stage as a successful supplier of total solutions for
the electrical and communications infrastructure of buildings and for FTTx
networks. We lead the way in innovations for applications such as information
and communications technology, power supply and safety, building automation and lifts.

Event arenas

Our systems are reliable and constitute a secure investment on your part. This
is all thanks to the years of experience and proven expertise of our engineers
and technicians. Datwyler is a one-stop source of customised solutions for all
your specific applications as attractive total solutions, with all the necessary
test certificates, authorisations and approvals and with long-term warranties.
Our workforce prides itself on delivering a full package of services for all the products and solutions supplied by the company. You can rely on our expert support
for all aspects of our supply beginning with planning, consultancy, through
pre-assembly, logistics, installation and ending with system maintenance.

FTTx projects

Datwyler

Datwyler
Worldwide expertise in turnkey creation, multi-site projects and services

Turnkey installations

Sa
f

rg

Imp

ut

En

om

atio

Electrical and
communications
infrastructure

Planning

Com
mu

on
ati
c
i
n

y
et

tenance
Main

Datwyler does not only supply integrated total solutions,


but has positioned itself successfully as a turnkey partner:
for all manner of purpose-built constructions including
multi-site projects and for FTTx projects. Our successful
processing of turnkey projects derives from our highlevel skills in developing and manufacturing the
required products and solutions, our comprei
v
c
Ad e
hensive applications expertise and the
international scope of Datwyler activities.

Build

a
i ng

l e me n tat i o n

Our international presence and our worldwide, actively


managed and certificated partner network have also
proved invaluable in the multi-site projects of major
clients. National and international companies rely on
Datwyler on-the-spot site audits. Using the site audits
as a base, our engineering experts work out customised solutions with uniform standards for all the sites
concerned. Our total solutions package is rounded
off by the implementation and assurance of regular
operations. While operations are running, we provide
servicing and maintenance work to optimise your infrastructure solution. These MAC (move, add, change)
services increase the performance and working life of
your equipment.
High-quality solutions for all your applications
Year on year, Datwyler invests in even better materials and process technologies, production resources
and test methods. This is why our system solutions
always keep ahead of the current norms and repeatedly set new standards. The important functions
which our solutions must deliver in practice demand
the highest possible level of safety and reliability.
This is why we measure each product against stringent quality standards before it leaves the company.


Datwyler

Of course, all our processes are ISO 9000-2001/14001


certified.
Opt for sustainable solutions that provide you with
high-level operational reliability coupled with low
operating costs. The proof that Datwyler systems
can deliver these benefits has been evident for many
years in thousands of installations around the world.
In addition, we have a particularly keen eye for consistent, intelligent solutions that simplify planning,
sourcing and installation and shorten your construction times.
We have the right total solutions for all your applications, whatever they are high-speed communications networks, modern energy distribution, monitoring and control duties, fire alarm systems or lift
cabling. Or you may want to integrate new systems,
interconnect and automate existing systems or simply ensure a reliable power supply. All this is possible
with our carefully thought out, pre-assembled and
prefabricated subsystems.
Just tell us how, when and where
Besides quality and product price, the logistics performance capability of suppliers is a decisive factor in
the successful handling of construction projects. This
is particularly true of major projects. With its years of
experience and high logistics competences, Datwyler can handle even time-critical major projects
smoothly and to the complete satisfaction of customers. Just-in-time deliveries at the right place are all
in a days work for us and our partners.

Besides delivering straight to the construction site, we


also offer you additional logistics services (time slots,
pre-fitted and pre-assembled products etc.). Many customers and suppliers have a direct link to our IT system for rapid and flexible order processing. As regards
cable pre-assembly, Datwyler also has wide-ranging
expertise, the product of decades of experience. In our
modern cable cutting centre, the engineering department passes the cutting orders electronically without
any media discontinuity straight to the production
area. Our efficient order communication system with
all our customers is due to years of experience with
B2B interfaces.
In the growth markets of Eastern Europe and the
Middle East we opened a branch recently. In many
countries Datwyler works in close co-operation with
independent distribution partners. Thus our customers
can rely on the consistently high quality standard of
all Datwyler products and solutions whilst benefiting
from local contacts and logistics services.
We support you in realising your infrastructure
project reliably, capably, complete and with the
highest quality!

Datwyler

Connections that work


in case of fire

Safety cable systems

Datwyler

Whether in football stadiums, airports or metro stations wherever masses


of people assemble in a confined space, the risk of catastrophe in case of fire
is especially great. Thats why special cabling systems are particularly important
systems that continue to function dependably even during a fire providing lifesaving security for an extended time. As a leading provider of safety cable systems,
Datwyler closely collaborates with fire-protection specialists to develop innovative
solutions. These systems provide continuous power and data transmission even
in a fire, and thus form the backbone of an effective fire-safety concept.

Mobility is increasing rapidly worldwide and with it the sizes


of crowds in airports and train stations. Other confined spaces in
which thousands of people congregate daily include office towers, shopping centres, event arenas and entertainment parks.
Safety standards meet cable technology
Fire-safety regulations are being continually tightened to minimise
fire damage and provide the best possible protection of life and
property. Datwyler is a step ahead in the race, offering innovative total solutions that incorporate electrical cable systems with
extended functional integrity. These systems go beyond the
toughest European norms. Functional integrity testing covers
not just individual cables but complete cable systems including
the associated supports and fasteners. In contrast to conventional insulation integrity testing, this method of comprehensive
testing reflects the actual performance of entire cable systems
installed in a buildings that catches on fire.
Patented ceramic technology
Datwyler has been producing safety cables using patented
ceramic technology for over ten years. The materials and processing of the ceramic-insulated products are being constantly
improved. The latest generation of cables offers a variety of tested, standard-compliant installation options that outperform
by far the conventional installation methods (in accordance
with DIN 4102-12).

Datwyler

Added value
for fire-safety systems

Safety cable systems

Leading know-how
As a provider of total solutions for safety cable systems, Datwyler possesses comprehensive know-how accumulated over decades:
- Co-development of extended functional integrity tests in collaboration with renowned
testing institutes in the early 1990s.
- Sound knowledge of safety engineering and building codes and standards.
- Leading material, production and process know-how in the fabrication of safety cables
incorporating patented and proven ceramic technology.
- Development of the first metal-free fibre-optic cable with E30 extended functional
integrity through combining existing technical competence in data and safety cable
engineering.
- Broad systems competence.
- Collaboration with renowned technical universities, international standard committees
and independent testing institutes.
Diverse applications
Datwyler safety cable systems with extended functional integrity are used wherever stringent fire-safety requirements must be met and people and property could be at risk due
to fire and smoke:
- Airports, train stations, metro stations
- Hotels and hospitals
- Sports stadiums, theatres and concert halls
- Office and exhibition buildings, public buildings
- Tunnels for road and rail

Datwyler

System solutions
- The pyrofil cable line includes halogen-free, low-smoke
emission and flame resistant safety cables with circuit integrity and functional integrity.
- The Safety product line includes support systems, mounting
components and appropriate accessories to ensure functional integrity.
- Our FO Safety cables are the first metal-free fibre-optic cables
with E30 extended functional integrity with reference to DIN
4102-12.
- Fire protection seminars and special calculation programmes
offer engineers and installers valuable support
- Comprehensive services up to and including turnkey and
multi-site projects

Galeria Krakowska, Krakow

Selected reference projects


Allianz Arena
Dexia BIL
International Airport
World Trade Center
Galeria Krakowska
New main station (Lehrter Bahnhof )
Crystal Plaza Towers

Munich Trade Fair


Luxembourg Reichstag
Frankfurt Subway
Dubai Metro
Krakow Gotthard motorway tunnel
Berlin Mercedes Benz Museum
United Arab Emirates

Stuttgart
Berlin
Munich
Prague
Gotthard
Stuttgart

Customer value in focus


Datwyler stands for more than the production and distribution of products. For your safety cabling systems we provide
everything from one source: modular system solutions with
high-quality cables and components, with all the necessary test
certificates and authorisations and with long-term warranties.
You can rely on our expert support for all aspects of our supply
beginning with planning, consultancy, through logistics, installation and ending with system maintenance. The interaction
of these elements creates added value. As a customer you benefit from cost-effective installation thanks to our innovative installation methods, sign-off without any difficulties, low insurance
rates, and dependable transmission of power and data even in
the event of fire.

Crystal Plaza Towers, United Arab Emirates

Datwyler

Safety concepts for buildings

Proven quality

Steel conduits
and halogen-free
plastic conduits

Datwyler is the first European manufacturer to develop a complete system solution that meets the demands of todays industry for reliable power supply and data transmission in the event
of fire. pyrofil cables and our approved cabling system components are the result of many years of intensive development in
coordination with the relevant standardisation bodies.

from page 115

Our safety cable systems have to be highly reliable when it


comes to practical operations. This is why Datwyler measures
each and every product against strict quality standards before
it leaves the company. Specifically, this means that all processes
are integrated into the comprehensive management system
in accordance with ISO 9001 and ISO 14001. Beyond this, additional application-specific inspection and test methods ensure
that pyrofil cables and Datwyler safety cable systems exceed
the requirements of our customers as well as the stringent standards specified by the various countries in which our products
are used.

from page 112

Fire protection plugs F90


Installation depth 30mm
from page 112

Screws F90

from page 114

Selected raw materials and special compounds in combination with unique installation methods are what give a Datwyler
system its high quality and maximum guaranty of safety in the
event of fire.
pyrofil cables and Datwyler safety system components are used
wherever people, machinery and equipment are endangered
by fire and smoke emission: in buildings with high density of
occupants as well as in facilities containing large concentrations
of valuable property.

Gas concrete plugs


F90

Single clamps
type SAS
Spacing 600mm
page 100

Strap clamps
without trough type B
Spacing 800mm
page 101

Strap clamps
with trough type B
Spacing 800mm
page 102

Identification signs
page 104

Firestop systems S90/S120


Plates/Mortar /Bricks/Plugs
from page 104

10

Datwyler

pyrofil Safety cables


E90 Keram

pyrofil Safety cable


E90 Keram

from page 74

from page 74

WUM
Support measure
from page 95

pyrofil Safety cables


E30-E60 Keram

Modular
shaft lighting system

from page 64

Flat form cable


with integrated data bus

Cable joints
E30 and E90 for all
dimensions
page 106

Elevator travelling
cables
Multi cable support
Hermanschelle E30/E90
Spacing 600/800mm

Fibre optic safety


cable, with reference to
DIN 4102-12, 30 Min.

Connection/terminal box
E30-E90

page 82

Distribution box
E30-E90
type Hercules

Cable trays and cable ladders


E30/E90
Spacing 1500mm

page103

page 108

page 96

page 107

Datwyler

11

Safety concepts for tunnels

Identification signs

Steel conduits
and halogen-free
plastic conduits

page 104

from page 115

pyrofil Safety cables


E30-E60 Keram
from page 64

Fire protection plugs F90


Installation depth 30mm
from page 112

Single clamps
type SAS V4A
Spacing 600mm
page 100

Gas concrete plugs F90


from page 112

Screws F90

from page 114

Distribution boxes
E30/E90
from page 108

Cable trays and


cable ladders
E30/E90
Spacing 1500mm
page96

Multi cable support


Hermanschelle E30/E90
Spacing 600/800mm
page 103

12

Datwyler

Flat form cable with


integrated data bus

pyrofil Safety cables


E30/E90 Keram
from page 64

Fibre optic safety cable


with reference to
DIN 4102-12, 30 Min.
page 82

Cable joints E30 and E90


for all dimensions
page 106

Distribution box
E30-E90
type Hercules
page 107

Strap clamps
without trough type B
Spacing 800mm
page 101

Strap clamps
with trough
type B
Spacing 800mm
page 102

pyrofil Safety cables


E30-E90 Keram

Emergency lighting
for escape routes
page 110

from page 64

Firestop systems S90/S120


Plates/Mortar/Bricks/Plugs
from page 104

Fibre optic safety cable


with reference to
DIN 4102-12, 30 min.
page 82

Datwyler

13

Cable technology for


highest safety requirements

Cable

Applications

Product range/Standards

Safety cables with extended functional integrity


Low voltage cables up to 0.6/1 kV
E30-E90; FE180; BS 6387 CWZ; PH30-120, Rf-1 11/2

Safety cables with circuit integrity and


extended functional integrity to maintain power supplies to sprinkler systems,
emergency lighting, smoke and heat
extraction systems, emergency lift
supplies and fire fighting lifts.

Single core cables from 1.5 to 630 mm2


Multi core cables from 1.5 to 300 mm2
Also available with mechanical
protection

Safety cables with circuit integrity and


extended functional integrity to maintain power supplies and data transmission to fire alarm systems, public address
and voice alarm systems.

Single or multi pair cables, individually


or collectively screened. Also available
as fire alarm cable and with mechanical
protection.

Universal fibre-optic cables for indoor


and outdoor applications.

Loose tube construction with up to


60 SM-/MM-fibres with non-metallic rodent protection.

with mechanical protection

Wiring and fire alarm cables up to 225 V


E30-E90; FE180; BS 6387 CWZ; PH30-120, Rf-1 11/2

BRANDMELDEKABEL

with mechanical protection

Fibre-optic safety cables


with reference to DIN 4102-12 30 min. (E30);
IEC 60331-25

Standards/Approvals
IEC, EN, CENELEC, BS, DIN VDE, SEV, NBN,
VKF, VdS, GOST-R, Ukraine

Standards/Approvals
IEC, EN, CENELEC, DIN VDE, SEV, NBN,
GOST-R

Standards/Approvals
IEC, EN, CENELEC, DIN VDE

Safety cables with circuit integrity


Fire alarm cables 300/500 V
BS 6387 CWZ; FE180; BS 8434-2, EN 50200
(PH 30-120) and Annex E

Safety cables with circuit integrity to


maintain power supplies and data transmission to fire alarm systems, emergency lighting, public address and voice
alarm systems.

with mechanical protection

Screened multi core cables


from 1.0 mm2 to 4 mm2.
Also available with mechanical
protection.
Standards/Approvals
BS, EN, CENELEC, LPCB, GOST-R

Safety cables with improved characteristics in case of fire


Low voltage cables up to 0.6/1 kV

Safety cables with improved characteristics in case of fire an alternative to


traditional PVC cables, where no circuit
integrity is required.

Single core cables from 1.5 to 630 mm2


Multi core cables from 1.5 to 300 mm2
Also available with mechanical protection and as flexible, oil resistant
version.
Standards/Approvals
IEC, EN, CENELEC, DIN VDE, SEV, GOST-R

14

Datwyler

System compatible
installation components

System components

Application

Single clamps, multi cable supports


Single clamps to install single cables or cable bundles
conforming to common practice.
Multiple cable supports for a cost effective installation
of several cables.
These components facilitate the quick and easy
retrospective/subsequent installation of cables.
Support systems
Special support systems to install several cables conforming
to common practice.
Approved for ceiling and wall mounting with possibility
of easy retrospective/subsequent installation of cables.
Corresponding fixing devices, such as fire safety dowels,
installation screws and setting tools are available for all
support systems.
Connecting technology
Cable joints to connect pyrofil safety cables with circuit
and extended functional integrity.
Distribution boxes with extended functional integrity E30-E90.
Also available as fire resistant covers to protect standard connections or junction blocks.
Distribution boxes with circuit integrity for high- and
low-voltage cables.
Firestop systems
Firestop systems S90/S120
- Firestop coated board S100 P
- Intumescent firestop paint S100 D
- Intumescent firestop mastic S100 SM-K
- Firestop bricks TS 90
- Firestop plugs TS 90

Seminars
Datwyler is setting new standards.
pyrofil safety cables combined with Datwyler system components make up the perfect and cost effective safety solution.

For further information please visit


www.datwyler.com

Datwyler regularly holds seminars on cabling systems with


integrated circuit and extended functional integrity as well
as on firestop systems.

Datwyler

15

Product features

The illustrated pictograms show the essential product


features and give an easy reference.
They are allocated to the articles on the data sheets
and provide you with a quick overview

16

Datwyler

Zero halogen,
non corrosive gases

Datwyler cables are halogen-free


and reduce possible damage to
health or material to a minimum.

IEC 60754-1 and IEC 60754-2,


EN 50267-2-1, EN 50267-2-2, EN 50267-2-3
VDE 0482-267 part 2-1, 2-2 and 2-3

Flame propagation

Datwyler cables use a high performance, flame retardant material


that is self extinguishing.

IEC 60332-1-2,
EN 60332-1-2,
VDE 0482-332-1-2

Flame spread

Datwyler cables are flame resistant


and prevent the propagation of a
fire from one location to another

IEC 60332-3-22 to 25 cat. A-D,


EN 60332-3-22 bis 25 cat. A-D,
VDE 0482-332-3-22 to 25 cat. A-D

Smoke density

Datwyler cables emit minimum


smoke in the event of fire.
Exit routes and fire brigade access
are not restricted.

IEC 61034-1 and IEC 61034-2,


EN 61034-1 and EN 61034-2,
VDE 0482-1034 part 1 and 2

Circuit integrity
[FE/PH]

Datwyler cables with circuit integrity


guarantee the function of a single
cable for a defined duration. (FE is
for flame time and influence time)

IEC 60331-1, IEC 60331-2 and part 21,23, 25,


EN 50200 with Annex E, EN 50362,
VDE 0472 part 814, VDE 0482-200,
VDE 0482-362,
BS 8434-2, BS 6387 (cat. C/W/Z)

System Circuit
integrity
[E30-E90]

Datwyler cables and the licensed


fixing systems guarantee the function
of the complete electrical cable
installation for a defined time.
(E30=30 minutes, E60=60 minutes,
E90=90 minutes)

DIN 4102 part 12 [E30-E90]


NBN 713.020 (Rf1, Rf1)

The most important test


procedures and their functions

Test on gases evolved during combustion


This test procedure provides information if the insulation material of the cable sheath
creates corrosive gases in the event of fire.
Halogen parts or other material in small quantities
can be easily identified with this test due to the strong
change of pH and conductivity.
The conductivity is < 10mS/mm

Standards
- IEC 60754-1 and IEC 60754-2
- EN 50267-2-1, EN 50267-2-2
- EN 50267-2-3
- VDE 0482-267 part 2-1, 2-2 and 2-3

Test for vertical flame propagation


(single insulated wire or cable)
This test method tests a 60 cm long cable sample for
burning behaviour.
The flame must extinguish itself and the burn damage
must not reach the upper end of sample.

Standards
- IEC 60332-1-2
- EN 60332-1-2
- VDE 0482-332-1-2

Test for vertical flame spread


(bunched wires or cables)
This test method tests a 360 cm long cable
bundle with regard to fire propagation.
The flames must extinguish themselves
and burn damage must not exceed a defined height.
Standards
- IEC 60332-3-22 up to 25 Cat A-D
- EN 60332-3-22 up to 25 Cat. A-D
- VDE 0482-332-3-22 up to 25 Cat. A-D

Measurement of smoke density


This test checks smoke development when burning
the cable or the impairment of the visibility by burning cables.
The reduction in light transparency is measured in a
standard chamber.

Standards
- IEC 61034-1 and IEC 61034-2
- EN 61034-1 and EN 61034-2
- VDE 0482-1034 part 1 and 2

Datwyler

17

The most important test


procedures and their functions

Test of circuit integrity (FE/PH)


This test establishes whether a single cable can maintain circuit
integrity during and after exposure to a fire for a time period of
at least 180 minutes. Cables which fulfil the requirements of this
test are marked with FE180 after their type designation.
There is no obligation to test the cable for functional integrity
beyond the designated period.
Remark:
This test is not equivalent to
the test for functional integrity
in accordance with DIN 4102-12
Test of Circuit integrity
(Fire alone)
- IEC 60331-11/-21/-23/-25 [>750C]
- BS 6387 (cat. C) [950C]
- VDE 0472-814 [>750C]

Test of
Circuit integrity
(Fire and water)
- BS 6387 (cat.W) [650C, 3A]
- VdS 3423 [>830C, 3A]
- EN 50200 Annex E [>830C, 2A]

Test of Circuit integrity


(Fire and mechanical shock)
- IEC 60331-1/-2 [>830C, 2A]
- EN 50200 (PH) [>830C, 2A]
- EN 50362 [> 830C, 2A]
- BS 6387 (cat.Z) [950C, 3A]

Test of System Circuit integrity


of electrical cable installations
This standard describes the requirements and the actions for the achievement of the functional integrity
of complete electrical cable installations in the event
of fire.
While the circuit integrity (FE/PH) provides only for the
test of single cables, the cables here are tested in connection with practical fixing systems.
It is important to appreciate that there is no connection between the two standards, circuit integrity (FE/
PH) and System Circuit integrity (E).
The test is carried out and certified from state recognised institutes.
Standards

- DIN 4102 part 12 (E30-E90)


- NBN 713-020 (Rf1, Rf11/2)

Better than the standard!


This test (E30-E90) is now the only worldwide standard for guaranteeing functional integrity
of the complete electrical cable installation, including the fixing components, under normal
operating conditions.

18

Datwyler

ROHS WEEE REACH

Statement Datwyler
As an environmentally conscious manufacturer and supplier of cabling solutions it is
our concern not to use any environmentally
harmful substances in our products.
Based on current information, the hereinmentioned guidelines / regulations for
banned substances are fully complied with.
Exceptions are noted as such on the relevant
data sheet.

ROHS

REACH

DIRECTIVE 2002/95/EC
OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL
of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic
equipment

REGULATION (EC) No 1907/2006


OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
of 18 December 2006 concerning the Registration,
Evaluation, Authorisation and Restriction of Chemicals
(REACH), establishing a European Chemicals Agency, amending Direcctive 1999/45/EC and repealing
Council Regulation (EEC) No 793/93 and Commission
Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC Commission Directives 91/155/EEC,
93/67/EEC, 93/105/EC and 200/21/EC

and
COMMISSION DECISION
of 24 September 2010 amending, for the purposes
of adapting to scientific and technical progress, the
Annex to Directive 2002/95/EC of the European Parliament and Council as regards exemptions for applications containing lead, mercury, cadmium, hexavalent
chromium, polybrominated biphenyls or polybrominated diphenyl ethers (2010/571/EU)

and
COMMISSION REGULATION (EU) No 143/2011
of 17 February 2011 amending Annex XIV to Regulation (EC) No 1907/2006 of the European Parliament and
of the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals

WEEE
DIRECTIVE 2002/96/EC
OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
of 27 January 2003 on waste electrical and electronic
equipment

Datwyler

19

pyrofil Safety Cables Product overview

H07Z-U/R

22 E0

H05Z-/H07Z-K

24 E0

NHXMH

26 E0

(N)HXM(St)H

28 E0

N2XH

30 E0

N2XCH

34 E0

FE5

36 FE5

FE5-CL

40 FE5

J-H(St)H...Bd, grey

42 E0

J-H(St)H...Bd, red

44 E0

Halogen-free safety cables


with circuit integrity

20

Standard Fire Safety cable

46 FE180 UK

Standard Fire Safety cable flex

48 FE180 UK

Enhanced Fire Safety cable

50 FE180 UK

Standard Fire Safety cable armoured

52 FE180 UK

pyrofil Keram FE180

54 FE180

pyrofil Keram FE180 flex

58 FE180

pyrofil Keram FE180-CL

60 FE180

Datwyler

Armoured

Ov. shield

Concentric

max. 90C

max. 70C

0.6/1 kV

450/750 V

300/500 V

max. 300 V

General properties

max. 225 V

BS

Rated voltage

SEV

EN/CLC/IEC

DIN VDE

System Circuit integrity E90

System Circuit integrity E60

System Circuit integrity E30

Design

Circuit integrity

Minimum smoke emission

Halogen-free safety cables

Fire resistant

Page Cat.

Flame retardant

Cable type

Halogen-free

Fire characteristics

Subject to technical modification.

Armoured

Ov. shield

Concentric

max. 90C

max. 70C

0.6/1 kV

General properties

450/750 V

300/500 V

max. 300 V

max. 225 V

BS

Rated voltage

SEV

EN/CLC/IEC

DIN VDE

System Circuit integrity E90

System Circuit integrity E60

System Circuit integrity E30

Design

Circuit integrity

Minimum smoke emission

Fire resistant

Page Cat.

Flame retardant

Cable type

Halogen-free

Fire characteristics

Halogen-free safety cables with circuit


integrity and System Circuit integrity
(N)HXH FE180 E30-E60
pyrofil Keram

64 E30-E60

(N)HXCH FE180 E30-E60


pyrofil Keram

68 E30-E60

(N)HXH FE180 E30-E60 CL


pyrofil Keram

70 E30-E60

(N)HXH FE180 E90


pyrofil Keram

74 E90

(N)HXCH FE180 E90


pyrofil Keram

78 E90

JE-H(St)H...Bd FE180 E30 L, orange


pyrofil Keram

80 E30

JE-H(St)HBd FE180 E30-E90, orange


pyrofil Keram

82 E30-E90

JE-H(St)H...Bd FE180 E30 L, red


pyrofil Keram

84 E30

JE-H(St)HBd FE180 E30-E90, red


pyrofil Keram

86 E30-E90

JE-H(St)HRHBd FE180 E30-E90, red


pyrofil Keram

88 E30-E90

ZGGFR Safety (Fibre optic safety cable)

90 (E30)

wbGGFR Safety (Fibre optic safety cable)

92 (E30)

Subject to technical modification.

Datwyler

21

Preventive fire protection

H07Z-U/R

Single insulated core


Halogen-free, with improved fire characteristics
CENELEC EN 50525-03-41 (HD 22.9)
Separator
> 10 mm2
Plastic tape

Conductor
Solid/stranded

Insulation
FRNC/LS0H

Application

Wiring for switches, distributors, devices and lighting in buildings. Suitable for laying in conduits
on or behind plasterwork and in closed installation ducts. Permitted operating temperature at
conductor of 90C, in accordance with HD 516.

Construction

Conductor
Insulation
Core colours

Bare copper, solid or stranded IEC 60228, EN 60228, (VDE 0295)


Crosslinked polymer, EN 50363-5, HD 22.9
Brown, black, grey, blue, green/yellow

Technical Properties

Rated voltage

Test voltage

450/750V
0.6/1kV for fixed installation
2500V, 50Hz

General Properties

Operating temperature

permanent installation
during installation

Fixing devices

Support systems

Safety cables

Product information

22

pyrofil H07Z-U/R 0511/e

Information

Accessories

Distribution boxes

Firestop systems

Subject to technical modification.

Zero halogen
non corrosive gases
Flame propagation
Smoke density

-40C to +90C
+5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Preventive fire protection

H07Z-U/R

Single insulated core


Halogen-free, with improved fire characteristics
CENELEC EN 50525-03-41 (HD 22.9)

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

kg/km

app. kg/km

15
24
38
58
96
154
240
336
480
672
912
1152
1440
1776
2304

20
32
47
67
110
167
260
351
478
684
931
1150
1480
1800
2390

app. mm
2,8
3,4
3,9
4,4
5,6
7,0
8,5
9,6
11,1
12,9
15,1
16,2
18,2
20,2
23,2

app. kWh/m
0,05
0,06
0,07
0,08
0,09
0,14
0,18
0,21
0,27
0,32
0,43
0,47
0,59
0,73
0,92

Support systems
















RE = circular, solid conductor
RM = circular, stranded conductor

n x mm2

Fixing devices

Information

Accessories

Distribution boxes

Firestop systems

Please specify required core colour when ordering. Additional dimensions available on request.

Subject to technical modification.

23

Preventive fire protection

H05Z-K / H07Z-K

Flexible single insulated core


Halogen-free, with improved fire characteristics
CENELEC EN 50525-03-41 (HD 22.9)
Separator
> 2,5 mm2
Plastic tape

Insulation
FRNC/LS0H

Conductor
Flexible

Application

Wiring for switches, distributors, devices and lighting in buildings. Suitable for laying in conduits
on or behind plasterwork and in closed installation ducts. Permitted operating temperature at
conductor of 90C, in accordance with HD 516.

Construction

Conductor

Insulation
Core colours

Bare copper, flexible, IEC 60228 Class 5, EN 60228 Class 5,


(VDE 0295 Class 5)
Crosslinked polymer, EN 50363-5, HD 22.9
Brown, black, grey, blue and green/yellow

Support systems

Technical Properties

Rated voltage


Test voltage

300/500V for cross sections 1.0mm2


450/750V for cross sections 1.5mm2
0.6/1kV for fixed installation, for cross sections 1.5mm2
2500V, 50Hz

Fixing devices

Safety cables

Product information

General Properties

Operating temperature

permanent installation
during installation

24

pyrofil H05Z-K / H07Z-K 0511/e

Information

Accessories

Distribution boxes

Firestop systems

Subject to technical modification.

Zero halogen
non corrosive gases
Flame propagation
Smoke density

-40C to +90C
+5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Preventive fire protection

H05Z-K / H07Z-K

Flexible single insulated core


Halogen-free, with improved fire characteristics
CENELEC EN 50525-03-41 (HD 22.9)

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load











n x mm2
1
1
1
1
1
1
1
1
1
1
1
1

x
x
x
x
x
x
x
x
x
x
x
x

0,75
1,0
1,5
2,5
4
6
10
16
25
35
50
70

kg/km
8
10
15
24
38
58
96
154
240
336
480
672

app. kg/km
11
14
19
32
51
73
115
177
273
371
530
736

app. mm
2,4
2,5
2,9
3,6
4,4
5,2
6,7
8,0
9,9
11,2
13,2
15,3

app. kWh/m
0,03
0,03
0,05
0,06
0,07
0,09
0,11
0,14
0,20
0,24
0,32
0,38

Support systems

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Please specify required core colour when ordering. Additional dimensions available on request.

Subject to technical modification.

25

Preventive fire protection

300/500V NHXMH

Power cable
Halogen-free, with improved fire characteristics
VDE 250-214
Insulation
Cross-linked PE
zero halogen

Sheath
FRNC/LS0H

Conductor
Solid/stranded

Application

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls
or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.
Permitted operating temperature at conductor of +70C.

Construction

Conductor

Insulation

Filler
Outer sheath
Core colours
Sheath colour
Imprint

Bare copper, solid or stranded, IEC 60228, EN 60228,


(VDE 0295)
Cross-linked polyethylene, CENELEC HD 604 S1
and VDE 0276-604 2XI1,
Halogen-free compound
Polyolefin compound, VDE 0250-214 HM2
CENELEC HD 308 S2 and VDE 0293
Grey
On request

Technical Properties

Nominal voltage
Test voltage

300/500V
2000V, 50Hz

General Properties

Minimum bending radius



Operating temperature

Zero halogen
non corrosive gases
Flame propagation
Flame spread
Smoke density

permanent installation
during installation
permanent installation
during installation

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil NHXMH 0511/e

Accessories
Information

26

Filler
Flame retardant,
zero halogen

Subject to technical modification.

4 x D (D = outer diameter)
6xD
-40C to +70C
+5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Preventive fire protection

300/500V NHXMH

Power cable
Halogen-free, with improved fire characteristics
VDE 250-214

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. kWh/m

RE
RE

29
48

100
115

8,5
9,0

0,33
0,40

149 254
154 369
154 677
154 678
173 842

3
3
3
3
3

x 1,5
x 2,5
x
4
x
6
x 10

RE
RE
RE
RE
RE

43
72
115
173
288

110
145
230
300
510

9,0
9,5
12,0
13,0
16,0

0,33
0,38
0,59
0,68
1,08

154 367
154 679
154 680
154 681
174 718

4
4
4
4
4

x 1,5
x 2,5
x
4
x
6
x 10

RE
RE
RE
RE
RE

58
96
154
230
384

130
200
290
390
620

9,5
10,5
12,5
14,0
17,0

0,38
0,46
0,70
0,83
1,25

154 368
154 370
154 371
154 372
169 929
169 930

5
5
5
5
5
5

x 1,5
x 2,5
x
4
x
6
x 10
x 16

RE
RE
RE
RE
RE
RM

72
120
192
288
480
768

150
205
340
455
730
1150

10,0
11,0
13,5
15,0
18,5
22,5

0,44
0,50
0,81
0,93
1,44
2,06

154 682
154 683

7
7

x 1,5
x 2,5

RE
RE

101
168

195
285

10,5
12,5

0,55
0,74

174 719

10

x 1,5

RE

144

330

14,5

0,92

156 849

12

x 1,5

RE

173

345

15,0

0,95

174 720
RE = circular, solid conductor
RM = circular, stranded conductor

24

x 1,5

RE

346

610

19,5

1,65

Information

Additional dimensions available on request.

Support systems

app. mm

x 1,5
x 2,5

Fixing devices

app. kg/km

2
2

Firestop systems

kg/km

154 675
154 676

Distribution boxes

n x mm2

Accessories

Subject to technical modification.

27

Preventive fire protection

(N)HXM(St)H

Shielded power cable 300/500V


Halogen free, with improved fire characteristics
VDE 0250-214
Filler
Flame retardant,
zero halogen

Sheath
FRNC/LS0H

Drain wire
Tinned
copper

Conductor
Solid/stranded

Application

For permanent installation in dry, damp or wet areas, on or behind plasterwork


or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.
Permitted operating temperature at conductor of +70C.

Construction

Conductor

Insulation

Filler
Shielding
Outer sheath
Core colours
Sheath colour
Imprint

Bare copper, solid or stranded, IEC 60228, EN 60228,


(VDE 0295)
Cross-linked polyethylene, CENELEC HD 604 S1
and VDE 0276-604 2XI1
Halogen-free compound
Al-laminated tape with tinned copper drain wire
Polyolefin compound, VDE 0250-214 HM2
CENELEC HD 308 S2, (VDE 0293)
Grey
On request

Technical Properties

Nominal voltage
Test voltage

300/500V
2000V, 50Hz

General Properties

Minimum bending radius



Operating temperature

Zero halogen
non corrosive gases
Flame propagation
Flame spread
Smoke density

permanent installation
during installation
permanent installation
during installation

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil (N)HXM(St)H 0511/e

Accessories
Information

28

Shielding
Al-laminated
tape

Insulation
Cross-linked PE
zero halogen

Subject to technical modification.

4 x D (D = outer diameter)
6xD
-40C to +70C
+5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Preventive fire protection

(N)HXM(St)H

Shielded power cable 300/500V


Halogen free, with improved fire characteristics
VDE 0250-214

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
n x mm2

kg/km

app. kg/km

app. mm

app. kWh/m

2
2

x 1,5
x 2,5

RE
RE

43
63

119
151

8,5
9,7

0,26
0,32

1301 193
1301 194

3
3

x 1,5
x 2,5

RE
RE

58
87

137
180

9,0
10,0

0,36
0,42

1301 212
1301 213

4
4

x 1,5
x 2,5

RE
RE

72
111

160
213

10,0
11,0

0,41
0,48

1301 214
1301 195
RE = circular, solid conductor
RM = circular, stranded conductor

5
5

x 1,5
x 2,5

RE
RE

87
135

187
253

11,0
12,0

0,48
0,56

Support systems

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Additional dimensions available on request.

Subject to technical modification.

29

Preventive fire protection

N2XH

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
CENELEC HD 604 S1, VDE 0276-604
Insulation
Cross-linked PE
zero halogen

Sheath
FRNC/LS0H

Conductor
Solid/stranded

Application

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete.
Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a
protective conduit is used. Permitted operating temperature at conductor of +90C.

Construction

Conductor

Insulation

Filler
Outer sheath

Core colours
Sheath colour
Imprint

Bare copper, solid or stranded, IEC 60228, EN 60228,


(VDE 0295)
Cross-linked polyethylene, CENELEC HD 604 S1
and VDE 0276-604
Halogen-free compound or plastic tape
Polyolefin compound, CENELEC HD 604 S1
and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Black
On request

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
4000V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 15* x D (single core cable)

12* x D (multicore cable)

(D = outer diameter)

permanent installation
*50% reduction if installation

at 30C and with a template
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,

VDE 0482-332-3-22/-24 Cat. A/C
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil N2XH 0511/e

Accessories
Information

30

Filler
Flame retardant,
zero halogen

Subject to technical modification.

Preventive fire protection

N2XH

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
CENELEC HD 604 S1, VDE 0276-604

No. of cores x cross section Core colours Cu content Total weight Outer diameter Fire load
4
4
6
6
10
10
16
16
25
25
35
35
50
50
70
70
95
95
120
120
150
150
185
185
240
240
300
300

RE
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow

kg/km

app. kg/km

38
38
58
58
96
96
154
154
240
240
336
336
480
480
672
672
912
912
1152
1152
1440
1440
1776
1776
2304
2304
2880
2880

75
75
97
97
140
140
202
202
302
302
397
397
523
523
745
745
986
986
1214
1214
1536
1536
1888
1888
2472
2472
2945
2945

app. mm
6,4
6,4
6,9
6,9
7,7
7,7
9,1
9,1
11,0
11,0
12,0
12,0
13,0
13,0
15,0
15,0
17,0
17,0
18,0
18,0
21,0
21,0
23,0
23,0
26,0
26,0
28,0
28,0

app. kWh/m
0,20
0,20
0,22
0,22
0,26
0,26
0,36
0,36
0,48
0,48
0,55
0,55
0,65
0,65
0,84
0,84
0,97
0,97
1,10
1,10
1,43
1,43
1,72
1,72
2,02
2,02
2,34
2,34

Support systems

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Information

Accessories

Additional dimensions available on request.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Fixing devices

170 000
170 022
170 001
170 002
170 015
170 023
170 003
170 014
170 004
170 005
170 010
170 026
170 006
170 007
170 018
170 030
170 008
170 009
170 019
170 025
170 020
191 566
170 011
170 031
170 012
170 016
170 013
170 029
RE = circular, solid conductor
RM = circular, stranded conductor

n x mm2

Firestop systems

Distribution boxes

Article No.

Safety cables

Product information

Subject to technical modification.

31

Preventive fire protection

N2XH

Safety cables

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
CENELEC HD 604 S1, VDE 0276-604

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
kg/km

app. kg/km

app. mm

app. kWh/m

x 1,5

RE

29

120

8,0

0,38

188 201
188 204
188 349
188 210
190 505
188 216

3
3
3
3
3
3

x 1,5
x 2,5
x
4
x
6
x 10
x 16

RE
RE
RE
RE
RE
RM

43
72
115
173
288
461

135
181
242
319
464
697

9,0
10,0
11,0
12,5
14,0
17,0

0,44
0,51
0,60
0,70
0,83
1,22

188 202
188 205
188 208
188 211
188 214
188 217
188 219
188 028
188 222
188 030
188 224
RE = circular, solid conductor
RM = circular, stranded conductor

4
4
4
4
4
4
4
4
4
4
4

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM

58
96
154
230
384
614
960
1344
1920
2688
3648

163
214
294
390
586
874
1332
1777
2343
3384
4490

10,0
11,0
12,0
14,0
16,0
19,0
23,0
26,0
29,0
35,0
39,0

0,52
0,60
0,72
0,83
1,03
1,50
2,14
2,57
3,15
4,17
5,16

Additional dimensions available on request.

Accessories
Information

32

n x mm2

190 524

Distribution boxes

Firestop systems

Fixing devices

Support systems

Subject to technical modification.

Preventive fire protection

N2XH

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
CENELEC HD 604 S1, VDE 0276-604

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25

RE
RE
RE
RE
RE
RM
RM

72
120
192
288
480
768
1200

193
256
352
475
708
1081
1631

11,0
12,0
13,0
15,0
17,0
21,0
25,5

0,62
0,71
0,85
0,99
1,22
1,87
3,32

170 095
170 096

7
7

x 1,5
x 2,5

RE
RE

101
168

230
315

12,0
13,0

0,73
0,85

170 104
170 105

10
10

x 1,5
x 2,5

RE
RE

144
240

326
447

15,0
16,0

1,03
1,20

170 099
170 106

12
12

x 1,5
x 2,5

RE
RE

173
288

365
510

15,0
17,0

1,14
1,33

170 107

14

x 1,5

RE

202

420

16,0

1,27

170 100

19

x 1,5

RE

274

511

18,0

1,58

170 101

24

x 1,5

RE

346

664

21,0

2,06

170 108
RE = circular, solid conductor
RM = circular, stranded conductor

30

x 1,5

RE

432

793

22,0

2,41

app. kWh/m

Information

Accessories

Additional dimensions available on request.

app. mm

Support systems

app. kg/km

5
5
5
5
5
5
5

Fixing devices

kg/km

188 203
188 206
188 357
188 358
188 215
188 218
188 220

Firestop systems

n x mm2

Distribution boxes

Subject to technical modification.

33

Preventive fire protection

N2XCH

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
CENELEC HD 604 S1, VDE 0276-604
Separator
Plastic tape

Sheath
FRNC/LS0H

Concentric conductor
Bare copper
wire

Insulation
Cross-linked PE
zero halogen

Filler
Flame retardant,
zero halogen

Application

For permanent installation in dry, damp or wet areas, on or behind plasterwork


or in walls or concrete. Also suitable for outdoor applications.
The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90C.

Construction

Conductor

Insulation

Filler
Concentric conductor
Separator
Outer sheath

Core colours
Sheath colour
Imprint

Bare copper, solid or stranded, IEC 60228, EN 60228,


(VDE 0295)
Cross-linked polyethylene, CENELEC HD 604 S1
and VDE 0276-604
Halogen-free compound or plastic tape
Bare copper wires with reinforced helix
Plastic tape
Polyolefin compound, CENELEC HD 604 S1
and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Black
On request

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
4000V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 12 x D (multicore cable)

(D = outer diameter)
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,

VDE 0482-332-3-22/-24 Cat. A/C
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil N2XCH 0511/e

Accessories
Information

34

Reinforcing helix
Bare copper
tape

Subject to technical modification.

Conductor
Solid/
stranded

Preventive fire protection

N2XCH

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
CENELEC HD 604 S1, VDE 0276-604

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
162
206

11,0
12,0

0,43
0,49

188 226
188 229
188 231
188 233
188 235
188 237
188 239
188 241
188 243

3
3
3
3
3
3
3
3
3

x 1,5 RE/1,5
x 2,5 RE/2,5
x
4 RE/4
x
6 RE/6
x 10 RE/10
x 16 RM/16
x 25 RM/16
x 35 RM/16
x 50 RM/25

66
104
161
240
408
643
902
1190
1723

180
234
319
430
611
924
1280
1634
2235

11,0
12,0
14,0
15,0
17,0
20,0
23,0
26,0
29,0

0,48
0,55
0,65
0,75
0,94
1,47
1,94
2,29
2,72

188 227
188 230
188 232
188 234
188 236
188 238
188 240
188 242
188 244
188 245
188 246
188 247
188 248
188 249
188 250

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

81
128
200
297
504
796
1142
1526
2203
3082
4208
5388
6540
8159
10546

205
269
375
510
745
1107
1572
2013
2759
3899
5164
6494
7959
9932
12989

12,0
13,0
15,0
16,0
18,0
21,0
25,0
28,0
32,0
38,0
42,0
46,0
52,0
57,0
65,0

0,56
0,64
0,79
0,92
1,10
1,75
2,36
2,75
3,38
4,48
5,44
6,38
7,97
9,86
12,01

170 156
170 191
170 192
170 193

7
7
7
7

x 1,5 RE/2,5
x 2,5 RE/2,5
x
4 RE/4
x
6 RE/6

133
200
315
470

286
373
532
727

14,0
15,0
17,0
18,0

0,78
0,89
1,11
1,25

170 157
170 195

12
12

x 1,5 RE/2,5
x 2,5 RE/4

205
334

429
600

17,0
19,0

1,18
1,40

170 158

24

x 1,5 RE/6

413

790

23,0

2,14

170 159

30

x 1,5 RE/6

499

921

25,0

2,52

840

1319

28,0

3,01

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120

170 196
30
x 2,5 RE/10
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request.

Subject to technical modification.

Support systems

app. kWh/m

52
80

Fixing devices

app. mm

x 1,5 RE/1,5
x 2,5 RE/2,5

Firestop systems

app. kg/km

2
2

Distribution boxes

kg/km

188 225
188 228

Accessories

n x mm2

Information

35

Developed especially for the Swiss market

Preventive fire protection

FE5

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
With reference to SEV TP 20B/3C
and CENELEC HD 604 S1 part 5. H

Insulation
Polyolefin
flame retardant, low smoke,
zero halogen

Conductor
Solid/stranded

Sheath
FRNC/LS0H

Application

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or
concrete. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90C.

Construction

Conductor
Insulation

Outer sheath

Core colours
Sheath colour
Imprint

Bare copper, solid or stranded, IEC 60228, EN 60228


Polyolefin compound, CENELEC HD 604 S1
part 5 sec. H
Flame retardant Polyolefin compound
CENELEC HD 604 S1 part 5 sec. H
CENELEC HD 308 S2
Orange/Black
On request

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
3500V, 50Hz

General Properties

Minimum bending radius


during and permanent installation



permanent installation

Operating temperature
permanent installation

during installation

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

36

pyrofil FE5 0511/e

Information

Accessories

Zero halogen
non corrosive gases

Flame propagation

Flame spread

Smoke density

Subject to technical modification.

15* x D (single core cable)


12* x D (multicore cable)
(D = outer diameter)
*50% reduction if installation
at 30C and with a template
-45C to +90C
-5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


SEV TP 20B/3C 3.4.4
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
SEV TP 20B/3C 3.4.1.1
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C
SEV TP 20B/3C 3.4.1.3
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
SEV TP 20B/3C 3.4.3

Preventive fire protection

FE5

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
With reference to SEV TP 20B/3C
and CENELEC HD 604 S1 part 5. H

Safety cables

Product information

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

16
16
25
25
35
35
50
50
70
70
95
95
120
120
150
150
185
185
240
240
300
300

RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow

kg/km

app. kg/km

app. mm

kWh/m

154
154
240
240
336
336
480
480
672
672
912
912
1152
1152
1440
1440
1776
1776
2304
2304
2880
2880

202
202
302
302
397
397
523
523
745
745
986
986
1214
1214
1536
1536
1888
1888
2472
2472
2945
2945

9,1
9,1
11
11
12
12
13
13
15
15
17
17
18
18
21
21
23
23
26
26
28
28

0,36
0,36
0,48
0,48
0,55
0,55
0,65
0,65
0,84
0,84
0,97
0,97
1,1
1,1
1,43
1,43
1,72
1,72
2,02
2,02
2,34
2,34

Fixing devices

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Firestop systems

170 003
170 014
170 004
170 005
170 010
170 026
170 006
170 007
170 018
170 030
170 008
170 009
170 019
170 025
170 020

170 011
170 031
170 012
170 016
170 013
170 029
RE = circular, solid conductor
RM = circular, stranded conductor

n x mm2

Support systems

Article No. No. of cores x cross section Core colour Cu content Total weight Outer diameter Fire load

Information

Accessories

Distribution boxes

Additional dimensions available on request.

Subject to technical modification.

37

Developed especially for the Swiss market

Preventive fire protection

FE5

Safety cables

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
With reference to SEV TP 20B/3C
and CENELEC HD 604 S1 part 5. H

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load

Firestop systems

Fixing devices

Support systems

kg/km

app. kg/km

app. mm

kWh/m

2
2

x 1.5
x 2.5

RE
RE

29
48

73
109

8
9

0,17
0,24






188 216

3
3
3
3
3
3

x 1.5
x 2.5
x
4
x
6
x 10
x 16

RE
RE
RE
RE
RE
RM

43
72
115
173
288
461

88
130
189
282
435
697

8
9
11
12
15
17

0,18
0,24
0,31
0,45
0,63
1,22






188 217
188 219
188 028
188 222
188 030
188 224
RE = circular, solid conductor
RM = circular, stranded conductor

4
4
4
4
4
4
4
4
4
4
4

x 1.5
x 2.5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM

58
96
154
230
384
614
960
1344
1920
2688
3648

115
169
247
352
543
874
1332
1777
2343
3384
4490

9
10
12
13
16
19
23
26
29
35
39

0,23
0,29
0,39
0,51
0,68
1,5
2,14
2,57
3,15
4,17
5,16

Information

Accessories

Distribution boxes

Additional dimensions available on request.

38

n x mm2

Subject to technical modification.

Preventive fire protection

FE5

Safety cable 0.6/1kV


Halogen-free, with improved fire characteristics
With reference to SEV TP 20B/3C
and CENELEC HD 604 S1 part 5. H

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. kg/km

5
5
5
5
5
5
5

x 1.5
x 2.5
x
4
x
6
x 10
x 16
x 25

RE
RE
RE
RE
RE
RM
RM

72
120
192
288
480
768
1200

144
212
310
433
690
1081
1631

app. mm
10,0
11,0
13,0
15,0
18,0
21,0
25,5

kWh/m
0,29
0,38
0,49
0,61
0,87
1,87
3,32

180 005
180 010
188 324
181 983
190 563

7
7
7
7
7

x 1.5
x 2.5
x
4
x
6
x 10

RE
RE
RE
RE
RE

101
168
269
403
672

185
275
410
572
902

10,0
12,0
14,0
16,0
20,0

0,34
0,45
0,59
0,73
1,03

8
8

x 1.5
x 2.5

RE
RE

115
192

211
317

11,0
13,0

0,38
0,50

180 961

10
10

x 1.5
x 2.5

RE
RE

144
240

267
402

13,0
16,0

0,50
0,67

181 020

RE = circular, solid conductor
RM = circular, stranded conductor

12
12

x 1.5
x 2.5

RE
RE

173
288

315
466

14,0
16,0

0,64
0,83

Support systems

kg/km


188 288
188 289
188 290
191 077
188 218
188 220

Fixing devices

n x mm2

Firestop systems

Information

Accessories

Distribution boxes

Additional dimensions available on request.

Subject to technical modification.

39

Developed especially for the Swiss market

Preventive fire protection

FE5-CL

Safety cable 0.6/1kV, armoured with rodent protection


Halogen-free, with improved fire characteristics
With reference to SEV TP 20B/3C
and CENELEC HD 604 S1 part 5. H

Sheath
FRNC/LS0H

Inner sheath
Polyolefin
flame retardant,
zero halogen

Conductor
Solid/stranded

Application

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or
concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth
or water if a protective conduit is used.
Permitted operating temperature at conductor of +90C.

Construction

Conductor
Insulation

Inner sheath

Armouring/
rodent protection

Outer sheath

Core colours
Sheath colour
Imprint

Bare copper, solid or stranded, IEC 60228, EN 60228


Crosslinked polyethylene
CENELEC HD 604 S1 part 5 sec. H
Flame retardant Polyolefin compound
CENELEC HD 604 S1 part 5 sec. H

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
3500V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 15* x D (single core cable)

12* x D (multicore cable)

(D = outer diameter)
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2

SEV TP 20B/3C 3.4.4
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2

SEV TP 20B/3C 3.4.1.1
Flame spread
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C

SEV TP 20B/3C 3.4.1.3
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

SEV TP 20B/3C 3.4.3

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil FE5-CL 0511/e

Accessories
Information

40

Insulation
Cross-linked PE
zero halogen

Armouring
Galvanised
steel tape

Subject to technical modification.

Single core cable with copper tape [CLCU) and Multicore cable
with galvanised steel tape [CL]
Flame retardant Polyolefin compound
CENELEC HD 604 S1 part 5 sec. H
CENELEC HD 308 S2
Black
On request

Preventive fire protection

FE5-CL

Safety cable 0.6/1kV, armoured with rodent protection


Halogen-free, with improved fire characteristics
With reference to SEV TP 20B/3C
and CENELEC HD 604 S1 part 5. H

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load

Subject to technical modification.

173
170
171
190
240
350
515
770
189
220
305
420
630
1000
1450
1950
270
375
510
760
820
1200
1750
2400
3200
4550
6050
230
330
460
651
980
272
389
329
470
367
530
850
1050

app. mm
10
10
10
11
12
14
16
20
10
11
13
15
17
22
26
30
12
14
16
19
21
24
28
33
37
44
50
11
13
15
17
21
13
15
14
17
15
17
22
24

kWh/m
0,30
0,40
0,33
0,43
0,53
0,72
0,96
1,55
0,38
0,50
0,62
0,80
1,08
1,92
2,53
3,26
0,61
0,77
0,96
1,31
1,53
2,17
2,85
3,94
4,90
6,60
8,64
0,54
0,71
0,91
1,15
1,58
0,62
0,82
0,77
1,01
0,94
1,26
2,00
2,16

Support systems

app. kg/km

29
48
43
72
115
173
288
461
58
96
154
230
384
614
960
1344
120
192
288
480
480
768
1200
1680
2400
3360
4560
101
168
269
403
672
115
192
144
240
173
288
504
389

Fixing devices

kg/km

Firestop systems

RE
RE
RE
RE
RE
RE
RE
RM
RE
RE
RE
RE
RE
RM
RM
RM
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE

Distribution boxes


2
x 1,5

2
x 2,5

3
x 1,5
191 007
3
x 2,5
191 091
3
x
4
191 645
3
x
6
191 568
3
x 10

3
x 16
191 672
4
x 1,5

4
x 2,5

4
x
4

4
x
6

4
x 10

4
x 16

4
x 25

4
x 35
191 064
5
x 2,5

5
x
4
190 595
5
x
6
188 389
5
x 10

5
x 10
190 401
5
x 16
191 063
5
x 25
191 090
5
x 35
191 036
5
x 50

5
x 70
191 600
5
x 95

7
x 1,5
180 930
7
x 2,5

7
x
4
180 929
7
x
6
184 531
7
x 10

8
x 1,5

8
x 2,5

10
x 1,5

10
x 2,5

12
x 1,5
192 240
12
x 2,5

21
x 2,5

27
x 2,5
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request.

Accessories

n x mm2

Information

41

Preventive fire protection

J-H(St)H...Bd

Wiring cable for telecomunication systems max. 300V


Halogen-free, with improved fire characteristics
VDE 0815
Separator
Plastic tape

Sheath
FRNC/LS0H

Drain wire
Tinned
copper

Conductor
Solid

Application

Installation cable with electrostatic shield in fire vulnerable areas with high concentration
of people and property value. For telecommunication and IT systems for lossless data
and signal transmission. Suitable for fixed laying in dry and humid rooms, on-wall and
in-wall, outdoor use, no laying underground. Not to be used for power transmission.
Permitted operating temperature at conductor of +70C.

Construction

Conductor
Insulation
Core idendification
Stranding
Shielding
Outer Sheath
Sheath colour

Bare copper, solid, 0.6 or 0.8mm diameter


Halogen-free polymer compound, EN 50290-2-26
DIN VDE 0815 (different colours)
Cores twisted to star-quads and quads to units
Al-laminated plastic-foil with drain wire, copper tinned
Halogen-free polymer compound, EN 50290-2-27
Grey

Electrical Properties

Rated voltage
Test voltage
Conductor resistance
Loop:

Insulation resistance
Capacity

max. 300 V
800V 50Hz

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

Distribution boxes

General Properties

pyrofil J-H(St)H...Bd 0511/e

Subject to technical modification.

0,6 mm max. 130 /km


0,8 mm max. 73,2 /km
min. 100 M x km
max. 120 nF/km

Minimum bending radius


permanent installation

during installation

Operation temperatur
permanent installation
Operation temperatur
during installation

Accessories
Information

42

Shielding
Al-laminated
plastic-foil

Insulation
Halogen-free
polymer compound

Zero halogen
non corrosive gases
Flame propagation
Flame spread
Smoke density

2,5 x D
7,5 x D
(D = outer diameter)
-30 C bis +70 C
- 5 C bis +50 C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Preventive fire protection

J-H(St)H...Bd

Wiring cable for telecomunication systems max. 300V


Halogen-free, with improved fire characteristics
VDE 0815

Safety cables

Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
app. kg/km

app. mm

app. kWh/m

2
2
2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x
x
x

0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6

9
14
25
37
59
116
172
229
286
342
455
568

33
49
92
101
146
310
352
464
573
661
876
1056

5,0
6,0
9,0
9,0
11,0
16,0
17,0
19,0
21,0
23,0
27,0
29,0

0,90
0,12
0,18
0,23
0,33
0,72
0,81
1,05
1,34
1,50
2,01
2,53

1
2
4
6
10
20
30
40
50
60
80
100

x
x
x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x
x
x

0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8

15
25
45
65
106
206
307
407
508
608
809
1010

56
69
136
152
230
508
599
787
973
1121
1476
1805

6,0
7,0
11,0
11,0
13,0
21,0
22,0
25,0
25,0
30,0
34,0
38,0

0,12
0,16
0,29
0,35
0,55
1,21
1,36
1,67
2,19
2,44
3,18
4,07

191 001
152 838
152 689
152 839
152 840
152 841
1159 967
1172 012
1172 013
1172 014
1172 015
1172 016

Support systems

kg/km

x
x
x
x
x
x
x
x
x
x
x
x

Fixing devices

n x mm
1
2
4
6
10
20
30
40
50
60
80
100

Firestop systems




152 833

152 834

152 835

152 836

152 837

154 450
1154 451

154 452

154 453

154 454

154 455

Information

Accessories

Distribution boxes

Additional dimensions available on request.

Subject to technical modification.

43

Preventive fire protection

J-H(St)H...Bd

Fire alarm cable max. 300V


Halogen-free, with improved fire characteristics
VDE 0815
Separator
Plastic tape

Insulation
Halogen-free
polymer compound

BRANDMELDEKABEL

Sheath
FRNC/LS0H

Drain wire
Tinned
copper

Conductor
Solid

Application

Installation cable with electrostatic shield in fire vulnerable areas with high concentration
of people and property value. For telecommunication and IT-systems for lossless data
and signal transmission. Suitable for fixed laying in dry and humid rooms, on-wall and
in-wall, outdoor use, no laying underground. Not to be used for power transmission.
Permitted operating temperature at conductor of +70C.

Construction

Conductor
Insulation
Core idendification
Stranding
Shielding
Outer Sheath
Sheath colour

Bare copper, solid, 0.6 or 0.8mm diameter


Halogen-free polymer compound, EN 50290-2-26
DIN VDE 0815 (different colours)
Cores twisted to star-quads and quads to units
Al-laminated plastic-foil with drain wire, copper tinned
Halogen-free polymer compound, EN 50290-2-27
Red

Electrical Properties

Rated voltage
Test voltage
Conductor resistance
Loop:

Insulation resistance
Capacity

max. 300 V
800V 50Hz

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

Distribution boxes

General Properties

pyrofil J-H(St)H...Bd BMK 0511/e

Subject to technical modification.

0,6 mm max. 130 /km


0,8 mm max. 73,2 /km
min. 100 M x km
max. 120 nF/km

Minimum bending radius


permanent installation

during installation

Operation temperatur
permanent installation
Operation temperatur
during installation

Accessories
Information

44

Shielding
Al-laminated
plastic-foil

Zero halogen
non corrosive gases
Flame propagation
Flame spread
Smoke density

2,5 x D
7,5 x D
(D = outer diameter)
-30 C bis +70 C
- 5 C bis +50 C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2

Preventive fire protection

J-H(St)H...Bd

Fire alarm cable max. 300V


Halogen-free, with improved fire characteristics
VDE 0815

Safety cables

Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
n x mm

kg/km

app. kg/km

15
25
45
65
106
206
307
407
508
608
809
1010

56
69
136
152
230
508
599
787
973
1121
1476
1805

app. mm
6,0
7,0
11,0
11,0
13,0
21,0
22,0
25,0
25,0
30,0
34,0
38,0

app. kWh/m
0,12
0,16
0,29
0,35
0,55
1,21
1,36
1,67
2,19
2,44
3,18
4,07

Support systems


184 707
1 x 2 x
0,8

157 892
2 x 2 x
0,8

157 893
4 x 2 x
0,8

157 894
6 x 2 x
0,8

157 895
10 x 2 x
0,8
1172 017
20 x 2 x
0,8
1172 018
30 x 2 x
0,8
1172 019
40 x 2 x
0,8

157 406
50 x 2 x
0,8
1172 020
60 x 2 x
0,8
1172 021
80 x 2 x
0,8
1172 022
100 x 2 x
0,8
Fire alarm cable with red sheath and imprint Brandmeldekabel (fire alarm cable).

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Additional dimensions available on request.

Subject to technical modification.

45

Preventive fire protection

Standard Fire Safety Cable

Fire alarm cable 300/500V


Halogen-free, with improved fire characteristics
BS 7629-1 and BS 5839-1 Standard
Inner covering
Glass fiber
tape

Sheath
FRNC/LS0H

Conductor
Solid

Cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation
Core colours


Inner covering
Shielding

Separator
Sheath
Sheath colour
Imprint

Bare copper, stranded, IEC 60228 and EN 60228


Special compound, BS EN 50363-5
2 cores + earth: blue, brown
3 cores + earth: brown, black, grey
4 cores + earth: blue, brown, black, grey
Glass fibre tape
Al-laminated tape and tinned copper drain wire
IEC 60228, EN 60228
Plastic tape
Polyolefin compound, BS 7655, LTS3
Red, white (other colours on request)
On request

Electrical Properties

Nominal voltage
Test voltage

300/500V
2000V, 50Hz

General Properties

Minimum bending radius


Operating Temperature

during and permanent installation 6 x D (D = outer diameter)


permanent installation
-15C to +90C
during installation
-5C to +50C

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

IEC 60754-1 and IEC 60754-2, EN 50267-2-1, EN 50267-2-2,


VDE 0482-267 part 2-1 and part 2-2
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/-24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180),
BS 6387 (cat. CWZ), BS EN 50200 Annex E (30 minutes),
BS EN 50200 (PH120), IEC 60331-2 (120 minutes), VDE 0482-200

Safety cables
Firestop systems

Fixing devices

Support systems

Application

pyrofil Standard Fire Safety Cable 0511/e

Distribution boxes
Accessories
Information

Drain wire
Tinned
copper

Product information

46

Shielding
Al-laminated
tape

Insulation
Fire resistant
special compound

Subject to technical modification.

Preventive fire protection

Standard Fire Safety Cable

Fire alarm cable 300/500V


Halogen-free, with improved fire characteristics
BS 7629-1 and BS 5839-1 Standard

Safety cables

Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. kg/km

app. mm

kWh/m

red
white
red
white
red
white

2
2
2
2
2
2

x
x
x
x
x
x

1,0
1,0
1,5
1,5
2,5
2,5

29
29
43
43
72
72

78
78
98
98
141
141

7,7
7,7
8,3
8,3
9,7
9,7

0,17
0,17
0,19
0,19
0,26
0,26

187 206
188 154
187 210
187 211
187 215
187 216

red
white
red
white
red
white

3
3
3
3
3
3

x
x
x
x
x
x

1,0
1,0
1,5
1,5
2,5
2,5

38
38
58
58
96
96

95
95
120
120
181
181

8,1
8,1
8,7
8,7
10,3
10,3

0,20
0,20
0,23
0,23
0,31
0,31

187 207
187 208
187 212
187 213
187 217
188 155

red
white
red
white
red
white

4
4
4
4
4
4

x
x
x
x
x
x

1,0
1,0
1,5
1,5
2,5
2,5

48
48
72
72
120
120

119
119
150
150
224
224

9,0
9,0
9,7
9,7
11,4
11,4

0,25
0,25
0,28
0,28
0,39
0,39

188 317

red

1,5

115

230

11,6

0,42

Information

Accessories

Distribution boxes

Additional dimensions available on request.

Support systems

kg/km

187 204
187 205
187 209
187 161
187 214
187 162

Fixing devices

n x mm2

Firestop systems

Subject to technical modification.

47

Preventive fire protection

Standard Fire Safety Cable

Fire alarm cable 300/500V, flex


Halogen-free, with improved fire characteristics
BS 7629-1 and BS 5839-1 Standard
Inner covering
Glass fibre
tape

Sheath
FRNC/LS0H

Conductor
Stranded

Cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation
Core colours


Inner covering
Shielding

Separator
Sheath
Sheath colour
Imprint

Bare copper, stranded, IEC 60228 and EN 60228


Special compound, BS EN 50363-5
2 cores + earth: blue, brown
3 cores + earth: brown, black, grey
4 cores + earth: blue, brown, black, grey
Glass fibre tape
Al-laminated tape and tinned copper drain wire
IEC 60228, EN 60228
Plastic tape
Polyolefin compound, BS 7655, LTS3
Red (white or black on request)
On request

Electrical Properties

Nominal voltage
Test voltage

300/500V
2000V, 50Hz

General Properties

Minimum bending radius


Operating temperature

during and permanent installation 6 x D (D = outer diameter)


permanent installation
-15C to +90C
during installation
-5C to +50C

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

IEC 60754-1 and IEC 60754-2, EN 50267-2-1, EN 50267-2-2,


VDE 0482-267 part 2-1 and part 2-2
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/-24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180) ,
BS 6387 (cat. CWZ), BS EN 50200 Annex E (30 minutes),
BS EN 50200 (PH120), IEC 60331-2 (120 minutes), VDE 0482-200

Safety cables
Firestop systems

Fixing devices

Support systems

Application

pyrofil Standard Fire Safety Cable flex 0511/e

Distribution boxes
Accessories
Information

Drain wire
Tinned
copper

Product information

48

Shielding
Al-laminated
tape

Insulation
Fire resistant
special compound

Subject to technical modification.

Preventive fire protection

Standard Fire Safety Cable

Fire alarm cable 300/500V, flex


Halogen-free, with improved fire characteristics
BS 7629-1 and BS 5839-1 Standard

Safety cables

Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load
n x mm2

kg/km

app. kg/km

app. mm

kWh/m

190 438
190 427
190 429

red
red
red

2 x
2 x
2 x

1,0
1,5
2,5

29
43
72

83
103
152

8,0
8,9
10,4

0,20
0,23
0,30


190 439

red
red
red

3 x
3 x
3 x

1,0
1,5
2,5

38
58
96

101
130
190

8,5
9,4
11,0

0,24
0,27
0,35



190 440

red
red
red

4 x
4 x
4 x

1,0
1,5
2,5

48
72
120

127
161
235

9,4
10,4
12,2

0,25
0,31
0,44

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Additional dimensions available on request.

Support systems

Subject to technical modification.

49

Preventive fire protection

Enhanced Fire Safety Cable

Fire alarm cable 300/500V


Halogen-free, with improved fire characteristics
BS 7629-1 and BS 5839-1
Inner covering
Glass fibre
tape

Sheath
FRNC/LS0H

Drain wire
Tinned
copper

Conductor
Solid

Application

Cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation
Core colours
Inner covering
Shielding

Separator
Sheath
Sheath colour
Imprint

Bare copper, solid, IEC 60228 and EN 60228


Special compound, BS EN 50363-5
2 cores + earth: blue, brown
Glass fibre tape
Al-laminated tape and tinned copper drain wire
IEC 60228, EN 60228
Plastic tape
Polyolefin compound, BS 7655, LTS3
Red (white or black on request)
On request

Electrical Properties

Nominal voltage
Test voltage

300/500V
2000V, 50Hz

General Properties

Minimum bending radius


Operating temperature

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

during and permanent installation 6 x D (D = outer diameter)


permanent installation
-15C to +90C
during installation
-5C to +50C
IEC 60754-1 and IEC 60754-2, EN 50267-2-1, EN 50267-2-2,
VDE 0482-267 part 2-1 and part 2-2
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/-24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IIEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180)
BS 6387 (cat. CWZ) and BS 8434-2 (120 minutes),
BS EN 50200 (PH120), IEC 60331-2 (120 minutes), VDE 0482-200

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil Enhanced Fire Safety Cable 0511/e

Distribution boxes
Accessories
Information

50

Shielding
Alu-laminated
tape

Insulation
Fire resistant
special compound

Subject to technical modification.

Preventive fire protection

Enhanced Fire Safety Cable

Fire alarm cable 300/500V


Halogen-free, with improved fire characteristics
BS 7629-1 and BS 5839-1

Safety cables

Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load

188 368
188 369
188 370
188 371

red
white
red
white

n x mm2
2
2
2
2

x
x
x
x

1,5
1,5
2,5
2,5

kg/km
43
43
72
72

app. kg/km
98
98
141
141

app. mm
8,3
8,3
9,7
9,7

kWh/m
0,19
0,19
0,26
0,26

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Stranded versions and additional dimensions available on request.

Subject to technical modification.

51

Preventive fire protection

Armoured Standard Fire Safety Cable


Fire alarm cable with steel wire braiding 300/500V
Halogen-free, with improved fire characteristics
with reference to BS 7629-1

Inner sheath
Polyolefin compound

Sheath
FRNC/LS0H

Shielding
Alu-laminated
tape

Drain wire
Tinned
copper

Insulation
Fire resistant
special compound

Conductor
Solid

Application

Armoured cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor of +90C.

Construction

Conductor

Insulation
Core colours


Inner covering
Shielding

Inner sheath
Armouring
Outer Sheath
Sheath colour
Imprint

Bare copper, solid or stranded in accordance with IEC 60228


and EN 60228
Special compound, BS EN 50363-5
2 cores + earth: brown, blue
3 cores + earth: brown, black, grey
4 cores + earth: brown, black, grey, blue
Glass fibre tape
Al-laminated tape and tinned copper drain wire
IEC 60228 class 1or 2, EN 60228
Polyolefin compound
GSWB, galvanised steel wire braid
Polyolefin compound, BS 7655 LTS3
Red (white or black on request)
On request

Electrical Properties

Nominal voltage
Test voltage

300/500V
2000V, 50Hz

General Properties

Minimum bending radius


Operating temperature

during and permanent installation 6 x D (D = outer diameter)


permanent installation
-15C to +90C
during installation
-5C to +50C

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

IEC 60754-1 and IEC 60754-2, EN 50267-2-1, EN 50267-2-2,


VDE 0482-267 part 2-1 and part 2-2
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/-24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180) ,
BS 6387 (cat. CWZ), BS EN 50200 (PH120),
IEC 60331-2 (120 minutes), VDE 0482-200

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

Distribution boxes

pyrofil Standard Fire Safety Cable 0511/e

Accessories
Information

52

Armouring
galvanised
steel wire braid

Inner covering
Glass fibre
tape

Subject to technical modification.

Preventive fire protection

Armoured Standard Fire Safety Cable

Fire alarm cable with steel wire braiding 300/500V


Halogen-free, with improved fire characteristics
with reference to BS 7629-1

Safety cables

Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load

184 580

red
red

n x mm2
2
2

x
x

1,5
2,5

kg/km
48
72

app. kg/km
190
250

app. mm
12,0
13,0

kWh/m
0,40
0,50

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Stranded versions and additional dimensions available on request.

Subject to technical modification.

53

Developed especially for the Swiss market

Preventive fire protection

FE180

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Filler
Flame retardant,
zero halogen

Sheath
FRNC/LS0H

Insulation
Crosslinked polymer
zero halogen

Conductor
Solid/stranded

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor +90C.

Construction

Conductor

Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint

Bare copper, solid or stranded in accordance with IEC 60228


and EN 60228
Special compound, HD 604 S1 part 5 H
HD 604 S1 part 5 H
Compound, HD 604 S1 part 5 H
CENELEC HD 308 S2
Orange
On request

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
3500V, 50Hz

General Properties

Minimum bending radius


during and permanent installation



permanent installation

Operating temperature
permanent installation

during installation

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

Zero halogen,
non corrosive gases
Flame propagation

Flame spread

Smoke density

Circuit integrity [FE/PH]

pyrofil Keram FE180 0511/e

Accessories
Information

54

Fire barrier
High-peformance
Keram compound

Subject to technical modification.

15* x D (single core cable)


12* x D (multicore cable)
(D = outer diameter)
*50% reduction if installation at
30C and with a template
-45C to +90C
-5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2,


SEV TP20B/3C 3.4.4
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2,
SEV TP20B/3C 3.4.1.1
IEC 60332-3-23/-24 Cat. B/C, EN 60332-3-23/-24 Cat. B/C,
VDE 0482-332-3-23/24 Cat. B/C, SEV TP20B/3C 3.4.1.3
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2,
SEV TP20B/3C 3.4.3
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),
SEV TP20B/3C 3.4.2

Preventive fire protection

FE180

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

154
240
336
480
672
912
1152
1440
1776
2304

227
329
428
565
783
1054
1281
1606
1983
2607

app. mm
9,8
11,3
12,4
13,9
15,7
18,1
19,2
21,4
23,6
26,8

kWh/m
0,34
0,43
0,48
0,58
0,68
0,91
0,97
1,20
1,46
1,81

191 118
191 119



186 952
190 404







2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

29
48
77
115
192
307
480
672
960
1334
1824
2304
2880
3552
4608

103
144
202
272
407
661
950
1219
1602
2218
2974
3563
4450
5514
7232

7,8
9,0
10,4
11,8
14,0
18,2
21,2
23,4
26,4
30,4
35,0
37,4
41,6
46,2
52,6

0,22
0,28
0,37
0,46
0,63
1,09
1,42
1,66
2,06
2,61
3,46
3,87
4,75
5,86
7,46

187 180
187 184
187 187
187 189

186 953
186 955
186 957
186 959
186 961
RE = circular, solid conductor
RM = circular, stranded conductor

3
3
3
3
3
3
3
3
3
3

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM

43
72
115
173
288
461
720
1008
1440
2016

122
171
243
333
502
811
1184
1529
2026
2844

8,3
9,5
11,0
12,5
14,8
19,3
22,6
24,9
28,2
32,7

0,25
0,31
0,41
0,51
0,69
1,19
1,56
1,80
2,24
2,88

Support systems

16
25
35
50
70
95
120
150
185
240

Fixing devices

x
x
x
x
x
x
x
x
x
x

Firestop systems

app. kg/km

1
1
1
1
1
1
1
1
1
1

Distribution boxes

kg/km

171 370
171 377
171 386
171 394
171 429
170 842
170 845
170 850
170 855
170 858

Accessories

n x mm2

Information

Additional dimensions available on request.

Subject to technical modification.

55

Developed especially for the Swiss market

Preventive fire protection

FE180

Safety cables

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load

56

n x mm2

kg/km

app. kg/km

187 182
190 502
192 352
192 353

186 967
186 968
186 969
186 970
186 971
186 972
186 973
186 974
187 548
187 077

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760
7104
9216

148
212
304
414
635
1009
1485
1929
2600
3618
4860
5890
7417
9164
12029

9,1
10,5
12,2
13,8
16,4
21,1
24,8
27,4
31,5
36,2
41,7
44,6
50,0
55,3
63,0

0,29
0,38
0,49
0,61
0,85
1,40
1,86
2,15
2,79
3,38
4,68
5,19
6,52
7,98
10,05

187 183
187 186
187 188
187 190

186 975
186 976
186 977
186 978
186 979
190 587




RE = circular, solid conductor
RM = circular, stranded conductor

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

72
120
192
288
480
768
1200
1680
2400
3360
4560
5760
7200
8880
11520

178
261
371
509
777
1223
1806
2384
3187
4440
6032
7290
9145
11284
14632

9,9
11,6
13,4
15,2
18,1
23,1
27,2
30,5
34,8
40,0
46,6
49,7
55,5
61,3
69,8

0,35
0,47
0,61
0,76
1,03
1,67
2,22
2,66
3,41
4,26
5,89
6,49
8,08
9,84
12,44

Additional dimensions available on request.

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Subject to technical modification.

app. mm

kWh/m

Preventive fire protection

FE180

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. mm

kWh/m

x 1,5
x 2,5
x
4
x
6
x 10

RE
RE
RE
RE
RE

101
168
269
403
672

222
322
464
652
1022

10,8
12,5
14,5
16,7
20,3

0,41
0,53
0,7
0,89
1,27

187 108

8
8

x 1,5
x 2,5

RE
RE

115
192

260
384

11,9
13,8

0,48
0,62

188 345

10
10

x 1,5
x 2,5

RE
RE

144
240

321
465

13,8
16,0

0,69
0,77

186 269
192 479

12
12

x 1,5
x 2,5

RE
RE

173
288

365
541

14,2
16,7

0,66
0,88

187 109

21
21

x 1,5
x 2,5

RE
RE

303
504

580
883

17,7
21,0

0,99
1,35

190 412

RE = circular, solid conductor
RM = circular, stranded conductor

27
27

x 1,5
x 2,5

RE
RE

389
648

755
1122

20,4
23,9

1,3
1,7

Information

Accessories

Additional dimensions available on request.

Support systems

app. kg/km

7
7
7
7
7

Fixing devices

kg/km

186 267
186 268

187 201

Firestop systems

n x mm2

Distribution boxes

Subject to technical modification.

57

Developed especially for the Swiss market

Preventive fire protection

FE180 flex

Control cable flex 300/500V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Filler
Flame retardant,
zero halogen

Sheath
FRNC/LS0H

Conductor
flexible

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint

Bare copper, flexible, IEC 60228 class 5, EN 60228


Special compound, HD 604 S1 part 5 H
HD 604 S1 part 5 H
Compound, HD 604 S1 part 5 H
CENELEC HD 308 S2
Orange
On request

Electrical Properties

Nominal voltage
Test voltage

300/500V
2000V, 50Hz

General Properties

Minimum bending radius



Operating temperature

permanent installation
during installation
permanent installation
during installation

Zero halogen,
non corrosive gases
Flame propagation

Flame spread

Smoke density

Circuit integrity [FE/PH]

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2,


SEV TP20B/3C 3.4.4
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2,
SEV TP20B/3C 3.4.1.1
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat.C, VDE 0482-332-3-24 Cat. C,
SEV TP20B/3C 3.4.1.3
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2,
SEV TP20B/3C 3.4.3
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),
SEV TP20B/3C 3.4.2

Safety cables
Firestop systems

Fixing devices

Support systems

Application

Distribution boxes
pyrofil Keram FE180 flex 0511/e

Accessories
Information

Insulation
Crosslinked polymer
zero halogen

Product information

58

Fire barrier
High performance
Keram
special compound

Subject to technical modification.

4 x D (D = outer diameter)
6xD
-45C to +90C
-5C to +50C

Preventive fire protection

FE180 flex

Control cable flex 300/500V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
3
4
5
5
5
5
7
8
12
16
21

x
x
x
x
x
x
x
x
x
x
x

1,5
4,0
1,5
2,5
4,0
6,0
1,5
1,5
1,5
1,5
1,5

kg/km
43
154
72
120
192
288
101
115
173
231
303

app. kg/km
123
345
182
268
419
580
221
272
310
406
521

app. mm
9
14
10
12
15
18
11
13
14
16
18

kWh/m
0,27
0,54
0,4
0,55
0,65
0,80
0,44
0,56
0,72
0,89
1,10

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

188 335

187 554
187 179


192 367
185 228
191 059
191 060
191 061
Additional dimensions available on request.

n x mm2

Support systems

Subject to technical modification.

59

Developed especially for the Swiss market

Preventive fire protection

FE180-CL

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and
CENELEC HD 604 S1 part 5.H
Inner sheath
Circuit integrity (FE180) in accordance with IEC 60331

Polyolefin
flame retardant, low
smoke, zero halogen

Sheath
FRNC/LS0H

Armouring
Galvanised
steel tape

Fire barrier
High-peformance
Keram compound

Insulation
Crosslinked polymer
zero halogen

Conductor
Solid/stranded

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation
Filler
Inner sheath
Armouring
[rodent protection]

Outer sheath
Core colours
Sheath colour
Imprint

Bare copper, solid or stranded, IEC 60228 and EN 60228


Special compound, HD 604 S1 part 5 H
HD 604 S1 part 5 H
Compound, HD 604 S1 part 5 H

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
3500V, 50Hz

General Properties

Minimum bending radius


during and permanent installation


Operating temperature
permanent installation

during installation

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

Zero halogen,
non corrosive gases
Flame propagation

Flame spread

Smoke density

Circuit integrity [FE/PH]

pyrofil Keram FE180-CL 0511/e

Accessories
Information

60

Filler
Flame retardant,
zero halogen

Subject to technical modification.

Single core cable with copper tape [CLCU] and multicore cable
with galvanised steel tape [CL]
Compound, HD 604 S1 part 5 H
CENELEC HD 308 S2
Orange
On request

15 x D (single core cable)


12 x D (multicore cable)
(D = outer diameter)
-45C to +90C
-5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2,


SEV TP20B/3C 3.4.4
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2,
SEV TP20B/3C 3.4.1.1
IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C,
SEV TP20B/3C 3.4.1.3
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2,
SEV TP20B/3C 3.4.3
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),
SEV TP20B/3C 3.4.2

Preventive fire protection

FE180-CL

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and
CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4,0
6,0
10
16
25
35
50
70
95
120
150

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM

kg/km

app. kg/km

43
72
115
173
288
461
720
1008
1440
2016
2736
3456
4320

211
256
373
487
656
1075
1491
1865
2404
3314
4369
5222
6460

app. mm
11
12
14
16
18
24
27
29
32
37
42
45
50

kWh/m
0,46
0,50
0,69
0,90
1,20
1,93
2,41
2,73
3,29
4,22
5,42
6,04
7,30

Information

Accessories

Distribution boxes

Firestop systems

Additional dimensions available on request.

3
3
3
3
3
3
3
3
3
3
3
3
3

Support systems


187 199
191 097
191 121
188 354
188 327







RE = circular, solid conductor
RM = circular, stranded conductor

n x mm2

Fixing devices

Subject to technical modification.

61

Developed especially for the Swiss market

Preventive fire protection

FE180-CL

Safety cables

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and
CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
kg/km

app. kg/km

4
4
4
4
4
4
4
4
4
4
4
4
4

x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM

58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760

251
336
454
538
872
1296
1820
2296
3035
4044
5426
6494
8140

12
14
16
17
21
25
29
32
36
40
46
49
54

0,54
0,56
0,79
1,06
1,48
2,20
2,78
3,16
4,02
5,05
6,52
7,26
8,72

187 202
191 038
188 350
188 353
188 397
187 154
186 984
187 132
187 131


RE = circular, solid conductor
RM = circular, stranded conductor

5
5
5
5
5
5
5
5
5
5
5

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM

72
120
192
288
480
768
1200
1680
2400
3360
4560

260
360
489
647
971
1536
2171
2808
3686
5053
6792

12
14
16
18
21
27
31
35
39
45
52

0,58
0,76
1,05
1,28
1,76
2,53
3,23
3,85
4,83
6,05
8,14

Additional dimensions available on request.

Information

62

n x mm2


191 595
187 167
188 352

186 980
186 981
186 982
190 589
192 488
192 429
192 430

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Subject to technical modification.

app. mm

kWh/m

Preventive fire protection

FE180-CL

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to SEV TP 20B/3C and
CENELEC HD 604 S1 part 5.H
Circuit integrity (FE180) in accordance with IEC 60331

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. mm

kWh/m

x 1,5
x 2,5
x
4
x
6
x 10

RE
RE
RE
RE
RE

101
168
269
403
672

349
481
655
803
1214

14
16
18
19
23

0,72
0,91
1,15
1,53
2,13

192 461
187 128
191 104

8
8
8

x 1,5
x 2,5
x
4

RE
RE
RE

115
192
308

406
493
684

15
16
18

0,85
1,04
1,36

10
10

x 1,5
x 2,5

RE
RE

144
240

498
677

18
20

1,05
1,32

12
12

x 1,5
x 2,5

RE
RE

173
288

546
781

18
21

1,12
1,52

21
21

x 1,5
x 2,5

RE
RE

303
504

849
1218

22
26

1,71
2,29



RE = circular, solid conductor
RM = circular, stranded conductor

27
27

x 1,5
x 2,5

RE
RE

389
648

1075
1527

25
29

2,16
2,87

Information

Accessories

Additional dimensions available on request.

Support systems

app. kg/km

7
7
7
7
7

Fixing devices

kg/km




188 355
188 356

Firestop systems

n x mm2

Distribution boxes

Subject to technical modification.

63

Preventive fire protection

FE180 E30-E60

Safety cable 0.6/1kV (N)HXH, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Filler
Flame retardant,
zero halogen

Sheath
FRNC/LS0H

Insulation
Crosslinked polymer
zero halogen

Conductor
Solid/
stranded

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E60* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation

Filler
Outer sheath

Core colours
Sheath colour
Imprint


Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295)


Double insulation, cross-linked, high-performance Keram
special compound, VDE 0266 HXI1
Flame retardant, halogen-free, thermoplastic compound
Flame retardant Polyolefin compound,
CENELEC HD 604 S1 and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Orange
Datwyler PYROFIL KERAM (N)HXH FE180 E30-E60 1kV
SWISS MADE N X MM2 VDE REG. NR. 7780 ORDER NO. YEAR
METRE MARKING
or on request

Electrical Properties

Rated voltage
Test voltage

0.6/1kV
4000V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 15* x D (single core cable)

12* x D (multicore cable)

(D = outer diameter)

permanent installation
*50% reduction if installation at

30C and with a template
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen,
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,

VDE 0482-332-3-22/24 Cat. A/C
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Circuit integrity [FE/PH]
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),

IEC 60331-1, IEC 60331-2 (120 minutes ),

EN 50200, VDE 0482-200 (PH120) and EN 50362,

VDE 0482-362 (120 minutes), BS 6387 C/W/Z
System Circuit integrity
DIN 4102 part 12, NBN 713-020 (Rf1)
[E30-E60]*

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil (N)HXH FE180/E30-E60 Keram 0511/e

Distribution boxes
Accessories
Information

64

Fire barrier
High-peformance
Keram compound

* System Circuit integrity is dependent on installation method.

Subject to technical modification.

Preventive fire protection

FE180 E30-E60

Safety cable 0.6/1kV (N)HXH, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
4
6
10
16
25
35
50
70
95
120
150
185
240

RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

38
58
96
154
240
336
480
672
912
1152
1440
1776
2304

90
113
158
227
329
428
565
783
1054
1279
1604
1981
2604

app. mm
7,1
7,6
8,4
9,8
11,3
12,4
13,9
15,7
18,1
19,2
21,4
23,6
26,8

kWh/m
0,21
0,23
0,27
0,34
0,43
0,48
0,58
0,68
0,91
0,97
1,20
1,46
1,81

186 280
186 921
186 922
186 923
186 924
186 952
187 221

2
2
2
2
2
2
2

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25

RE
RE
RE
RE
RE
RM
RM

29
48
77
115
192
307
480

178
217
272
337
459
661
950

11,0
11,8
12,8
13,8
15,4
18,2
21,2

0,48
0,54
0,62
0,70
0,83
1,09
1,42

186 925
186 926
186 927
186 928
186 929
186 953
186 955
186 957
186 959
186 961
RE = circular, solid conductor
RM = circular, stranded conductor

3
3
3
3
3
3
3
3
3
3

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM

43
72
115
173
288
461
720
1008
1440
2016

200
250
319
403
560
811
1184
1529
2026
2844

11,5
12,4
13,5
14,6
16,3
19,3
22,6
24,9
28,2
32,7

0,53
0,60
0,68
0,77
0,91
1,19
1,56
1,80
2,24
2,88

Support systems

x
x
x
x
x
x
x
x
x
x
x
x
x

Fixing devices

app. kg/km

1
1
1
1
1
1
1
1
1
1
1
1
1

Firestop systems

kg/km

171 289
171 290
171 291
171 370
171 377
171 386
171 394
171 429
170 842
170 845
170 850
170 855
170 858

Distribution boxes

n x mm2

Accessories

Information

Additional dimensions available on request.


* Circuit integrity is dependent on installation method

Subject to technical modification.

65

Preventive fire protection

FE180 E30-E60

Safety cables

Safety cable 0.6/1kV (N)HXH, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load

186 930
186 931
186 932
186 933
186 934
186 967
186 968
186 969
186 970
186 971
186 972
186 973
186 974
187 548
187 077
RE = circular, solid conductor
RM = circular, stranded conductor

Information

66

3
3
3
3
3
3
3
3

x
x
x
x
x
x
x
x

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Additional dimensions available on request.


* Circuit integrity is dependent on installation method

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

186 954
186 956
186 958
186 960
186 962
186 963
186 964
186 965

n x mm2

Subject to technical modification.

25 + 1
35 + 1
50 + 1
70 + 1
95 + 1
120 + 1
150 + 1
185 + 1

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

x
x
x
x
x
x
x
x

16
16
25
35
50
70
70
95

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

RM
RM
RM
RM
RM
RM
RM
RM

kg/km

app. kg/km

874
1162
1680
2352
3216
4128
4992
6240

1361
1692
2311
3171
4276
5303
6417
8040

app. mm
23,9
25,9
29,9
34,0
39,3
42,6
46,6
52,0

kWh/m
1,73
1,93
2,52
3,07
4,18
4,74
5,63
6,99

58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760
7104
9216

234
296
381
490
695
1009
1485
1929
2600
3618
4860
5890
7417
9160
12043

12,4
13,4
14,6
15,8
17,8
21,1
24,8
27,4
31,5
36,2
41,7
44,6
50,0
55,3
63,0

0,61
0,69
0,78
0,90
1,07
1,40
1,86
2,15
2,79
3,38
4,68
5,19
6,52
7,98
10,05

Preventive fire protection

FE180 E30-E60

Safety cable 0.6/1kV (N)HXH, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM

72
120
192
288
480
768
1200
1680
2400
3360
4560

278
353
456
589
832
1223
1806
2384
3187
4440
6032

13,4
14,5
15,8
17,2
19,3
23,1
27,2
30,5
34,8
40,0
46,6

0,71
0,81
0,93
1,05
1,25
1,67
2,22
2,66
3,41
4,26
5,89

171 272
171 273

7
7

x 1,5
x 2,5

RE
RE

101
168

331
426

14,4
15,6

0,81
0,92

171 279
171 280

12
12

x 1,5
x 2,5

RE
RE

173
288

513
675

18,3
20,0

1,20
1,37

171 283
171 284

19
19

x 1,5
x 2,5

RE
RE

274
456

715
953

21,2
23,2

1,63
1,83

171 285
171 286

24
24

x 1,5
x 2,5

RE
RE

346
576

901
1205

24,6
27,0

1,99
2,27

171 287
171 288
RE = circular, solid conductor
RM = circular, stranded conductor

30
30

x 1,5
x 2,5

RE
RE

432
720

1057
1446

26,0
28,8

2,28
2,68

kWh/m

Information

Additional dimensions available on request.


* Circuit integrity is dependent on installation method

app. mm

Support systems

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95

Fixing devices

app. kg/km

5
5
5
5
5
5
5
5
5
5
5

Firestop systems

kg/km

186 935
186 936
186 937
186 938
186 939
186 975
186 976
186 977
186 978
186 979
190 587

Distribution boxes

n x mm2

Accessories

Subject to technical modification.

67

Preventive fire protection

(N)HXCH FE180 E30-E60

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Sheath
FRNC/LS0H

Separator
Plastic tape

Reinforcing
helix
Bare copper
tape

Insulation
Crosslinked polymer
zero halogen

Filler
Flame retardant,
zero halogen

Conductor
Solid/stranded

Fire barrier
High-peformance
Keram compound

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E60* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation

Filler
Concentric conductor
Separator
Outer sheath

Core colours
Sheath colour
Imprint


Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295)


Double insulation, cross-linked, high-performance Keram
special compound, VDE 0266 HXI1
Flame retardant, halogen-free, thermoplastic compound
Bare copper wires with reinforced helix
Plastic tape
Polyolefin compound, CENELEC HD 604 S1
and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Orange
Datwyler PYROFIL KERAM (N)HXCH FE180 E30-E60 1kV
SWISS MADE N X MM2 VDE REG. NR. 7780 ORDER NO. YEAR
METRE MARKING
or on request

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
4000V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 15 x D (single core cable)

12 x D (multicore cable)

(D = outer diameter)
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen,
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,

VDE 0482-332-3-22/24 Cat. A/C
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Circuit integrity [FE/PH]
IEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180)

IEC 60331-1, IEC 60331-2 (120 minutes),

EN 50200, VDE 0482-200 (PH120) and EN 50362,

VDE 0482-362 (120 minutes), BS 6387 C/W/Z
System Circuit integrity
DIN 4102 part 12
[E30-E60]*

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil (N)HXCH FE180/E30-E60 Keram 0511/e

Distribution boxes
Accessories
Information

68

Concentric conductor
Bare copper
wire

* System Circuit integrity is dependent on installation method.

Subject to technical modification.

Preventive fire protection

(N)HXCH FE180 E30-E60

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RE/1,5
RE/2,5
RE/4
RE/6
RE/10

52
80
123
182
312

224
273
355
436
622

12,7
13,5
15,0
16,0
18,0

0,60
0,66
0,78
0,86
1,07

186 945
186 946
187 233
187 235
187 237
187 238
187 239
187 240
187 241
187 242
186 985
186 986
186 987
187 243
186 988

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120

66
104
161
240
408
643
902
1190
1723
2410
3296
4236
5100
6383
8242

248
308
404
504
727
1148
1437
1796
2408
3381
4513
5576
6799
8300
11065

13,2
14,1
15,7
16,8
18,9
23,9
25,0
27,3
30,8
36,0
41,1
44,5
49,2
56,0
61,5

0,65
0,72
0,84
0,94
1,15
1,63
1,90
2,20
2,84
3,52
4,66
5,30
6,46
7,90
9,93

186 947
186 948
186 949
186 950
186 951
186 989
186 990
186 991
186 992
186 993
186 994
186 995
186 996
186 997
186 998

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120

81
128
200
297
504
796
1142
1526
2203
3082
4208
5388
6540
8159
10546

286
358
473
621
868
1254
1752
2210
3049
4198
5600
6940
8500
10615
13830

14,1
15,1
16,8
18,1
20,1
23,4
27,2
29,8
34,8
39,5
45,2
49,1
54,3
59,8
67,9

0,73
0,82
0,96
1,13
1,33
1,70
2,20
2,56
3,41
4,18
5,58
6,37
7,83
9,55
12,00

187 244

1,5

RE/2,5

133

393

16,1

0,94

499

1252

29,1

2,67

187 245
30 x
1,5
RE/6
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request. * Circuit integrity is dependent on installation method

Subject to technical modification.

Support systems

kWh/m

1,5
2,5
4
6
10

Fixing devices

app. mm

x
x
x
x
x

Firestop systems

app. kg/km

2
2
2
2
2

Distribution boxes

kg/km

186 943
186 944
187 232
187 234
187 236

Accessories

n x mm2

Information

69

Preventive fire protection

(N)HXH CL FE180 E30-E60

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Sheath
FRNC/LS0H

Inner sheath
Polyolefin
flame retardant,
low smoke,
zero halogen

Fire barrier
High performance
Keram
special compound

Insulation
Crosslinked polymer
zero halogen

Conductor
Solid/stranded

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of circuit integrity E30-E60* in accordance with DIN 4102-12.
Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.

Construction

Conductor
Insulation

Filler
Inner sheath

Armouring
[rodent protection]
Outer sheath

Core colours
Sheath colour
Imprint


Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295)


Double insulation, cross-linked, high-performance Keram
special compound, VDE 0266 HXI1
Flame retardant, halogen-free, thermoplastic compound
Flame retardant Polyolefin compound,
CENELEC HD 604 S1 and VDE 0276-604 HM4
Single core cable with copper tape [CLCU] and multicore cable
with galvanised steel tape [CL]
Flame retardant Polyolefin compound,
CENELEC HD 604 S1 and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Orange
Datwyler PYROFIL KERAM (N)HXH CLCU or CL FE180 E30-E60 1kV
N X MM2 VDE REG. NR. 7800 YEAR ORDER NO. SWISS MADE
METRE MARKING
or on request

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
4000V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 15 x D (single core cable)

12 x D (multicore cable)

(D = outer diameter)
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen,
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,

VDE 0482-332-3-22/24 Cat. A/C
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Circuit integrity [FE/PH]
IEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180),

BS 6387 C/W/Z
System Circuit integrity
DIN 4102 part 12
[E30-E60]*

* System Circuit integrity is dependent on installation method.

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil (N)HXH CL FE180/E30-E60 Keram 0511/e

Distribution boxes
Accessories
Information

70

Armouring
Galvanised
steel tape

Filler
Flame retardant
zero halogen

Subject to technical modification.

Preventive fire protection

(N)HXH CL FE180 E30-E60

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM

29
48
77
115
192
307
480
672
960
1344
1824
2304
2880
3552

336
385
453
531
673
911
1239
1536
1956
2640
3476
4119
5087
6268

15
16
17
18
20
22
25
28
31
35
40
42
47
52

0,94
1,02
1,13
1,25
1,43
1,79
2,22
2,64
3,04
3,79
4,89
5,47
6,62
8,13

191 107
186 940
192 351
188 326
191 597
188 327







RE = circular, solid conductor
RM = circular, stranded conductor

3
3
3
3
3
3
3
3
3
3
3
3
3

x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM

43
72
115
173
288
461
720
1008
1440
2016
2736
3456
4320

364
426
509
607
785
1075
1491
1865
2404
3315
4369
5222
6460

16
17
18
19
21
24
27
29
32
37
42
45
50

1,00
1,10
1,22
1,35
1,54
1,93
2,41
2,73
3,29
4,22
5,42
6,04
7,30

kWh/m

Information

Additional dimensions available on request.


* Circuit integrity is dependent on installation method

app. mm

Support systems

x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fixing devices

app. kg/km

2
2
2
2
2
2
2
2
2
2
2
2
2
2

Firestop systems

kg/km

192 350
187 562
191 612
187 563









Distribution boxes

n x mm2

Accessories

Subject to technical modification.

71

Preventive fire protection

(N)HXH CL FE180 E30-E60

Safety cables

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load

72

n x mm2

kg/km

app. kg/km


190 590
191 102


186 980
186 981
186 982
190 589


4
4
4
4
4
4
4
4
4
4
4
4

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
x 120

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM

58
96
154
230
384
614
960
1344
1920
2688
3648
4608

410
485
585
710
940
1296
1820
2296
3037
4157
5498
6595

17
18
19
20
22
25
29
32
36
41
47
50

1,11
1,22
1,36
1,51
1,76
2,2
2,78
3,16
4,02
5,05
6,52
7,26

192 347
188 117
188 118
186 941
186 942
190 525
186 984
190 529
191 565

5
5
5
5
5
5
5
5
5
5
5

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM

72
120
192
288
480
768
1200
1680
2400
3360
4560

466
556
676
826
1096
1460
2171
2730
3620
5054
6792

18
19
20
21
24
26
31
35
39
45
52

1,25
1,38
1,54
1,72
1,98
2,53
3,23
3,85
4,83
6,05
8,14



188 094


RE = circular, solid conductor
RM = circular, stranded conductor

6
6
6
6
6

x 1,5
x 2,5
x
4
x
6
x 10

RE
RE
RE
RE
RE

86
144
230
346
576

521
625
693
943
1269

19
20
20
23
25

1,39
1,54
1,74
1,94
2,26

Additional dimensions available on request.


* Circuit integrity is dependent on installation method

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Subject to technical modification.

app. mm

kWh/m

Preventive fire protection

(N)HXH CL FE180 E30-E60

Safety cable 0.6/1kV armoured with rodent protection, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E30-E60* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
101
168
269
403
672

532
643
799
987
1343

19
20
21
23
25

1,38
1,53
1,71
1,9
2,2



188 095

8
8
8

x 1,5
x 2,5
x
4

RE
RE
RE

115
192
307

605
732
916

20
21
23

1,53
1,69
1,91

10
10
10

x 1,5
x 2,5
x
4

RE
RE
RE

144
240
384

701
858
1080

22
24
26

1,78
1,98
2,24


185 239

12
12
12

x 1,5
x 2,5
x
4

RE
RE
RE

173
288
461

764
873
1205

23
23
26

1,9
2,13
2,42

14
14

x 1,5
x 2,5

RE
RE

202
336

847
1062

23
25

2,07
2,34

185 233

16
16

x 1,5
x 2,5

RE
RE

231
384

926
1155

24
26

2,24
2,52

21
21

x 1,5
x 2,5

RE
RE

303
504

1093
1381

27
29

2,58
2,89

27
27

x 1,5
x 2,5

RE
RE

389
648

1311
1681

29
32

3,06
3,45

185 235
30
x 1,5
185 241
30
x 2,5
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request.
* Circuit integrity is dependent on installation method

RE
RE

432
720

1407
1848

30
33

3,25
3,81

Subject to technical modification.

Support systems

kWh/m

RE
RE
RE
RE
RE

Fixing devices

app. mm

x 1,5
x 2,5
x
4
x
6
x 10

Firestop systems

app. kg/km

7
7
7
7
7

Distribution boxes

kg/km

185 232

185 245
185 247
185 248

Accessories

n x mm2

Information

73

Preventive fire protection

(N)HXH FE180 E90

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E90 in accordance with DIN 4102-12

Filler
Flame retardant,
zero halogen

Sheath
FRNC/LS0H

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
4000V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 15* x D (single core cable)

12* x D (multicore cable)

(D = outer diameter)

permanent installation
*50% reduction if installation at

30C and with a template
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen,
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,

VDE 0482-332-3-22/24 Cat. A/C
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Circuit integrity [FE/PH]
IEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180)

IEC 60331-1, IEC 60331-2 (120 minutes ),

EN 50200, VDE 0482-200 (PH120) and EN 50362,

VDE 0482-362 (120 minutes), BS 6387 C/W/Z
System Circuit integrity [E90] DIN 4102 part 12
System Circuit integrity
under effect of water
VdS 3423 [single core cable 16mm2]

Safety cables
Support systems
Fixing devices
Firestop systems

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E90 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.
Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295)
Double insulation, cross-linked, high-performance Keram
special compound, VDE 0266 HXI1
Flame retardant, halogen-free, thermoplastic compound
Flame retardant Polyolefin compound,
CENELEC HD 604 S1 and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Orange
Datwyler PYROFIL KERAM (N)HXH FE180 E90 1kV N X MM2
VDE REG. NR. 7780 Vds ORDER NO. SWISS MADE YEAR
METRE MARKING
or on request

pyrofil (N)HXH FE180/E90 Keram 0511/e

Distribution boxes
Accessories

Conductor
Solid/
stranded

Conductor
Insulation

Filler
Outer sheath

Core colours
Sheath colour
Imprint


Construction

Information

Insulation
Crosslinked polymer
zero halogen

Product information
Application

74

Fire barrier
High-peformance
Keram compound

Subject to technical modification.

Preventive fire protection

(N)HXH FE180 E90

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E90 in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

154
240
336
480
672
912
1152
1440
1776
2304
2880

243
347
449
589
810
1090
1318
1648
2029
2658
3166

app. mm
10,2
11,7
12,8
14,3
16,1
18,5
19,6
21,8
24,0
27,2
29,6

kWh/m
0,35
0,43
0,49
0,58
0,67
0,85
0,91
1,11
1,32
1,63
1,91

188 359
187 247
187 248
187 249
187 250
187 254
187 255
187 256
187 257
187 258
187 259
187 260

2
2
2
2
2
2
2
2
2
2
2
2

x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
x 120

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM

29
48
77
115
192
307
480
672
960
1344
1824
2304

178
217
272
337
459
714
1011
1287
1742
2346
3130
3729

11,0
11,8
12,8
13,8
15,4
19,0
22,0
24,2
28,0
31,6
36,2
38,6

0,48
0,54
0,62
0,70
0,83
1,19
1,54
1,79
2,35
2,86
3,67
4,11

186 174
3
x 1,5
186 177
3
x 2,5
186 182
3
x
4
186 186
3
x
6
186 189
3
x 10
186 152
3
x 16
186 153
3
x 25
186 154
3
x 35
186 207
3
x 50
187 261
3
x 70
187 262
3
x 95
187 263
3
x 120
187 264
3
x 150
187 265
3
x 185
187 266
3
x 240
RE = circular, solid conductor, RM = circular, stranded conductor

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

43
72
115
173
288
461
720
1008
1440
2016
2736
3456
4320
5328
6912

200
250
319
403
560
878
1299
1664
2189
2997
4007
4812
5988
7363
9632

11,5
12,4
13,5
14,6
16,3
20,2
24,0
26,4
29,8
33,9
38,9
41,5
46,0
50,7
57,6

0,53
0,60
0,68
0,77
0,91
1,29
1,75
2,02
2,51
3,09
3,95
4,39
5,32
6,44
8,10

Support systems

16
25
35
50
70
95
120
150
185
240
300

Fixing devices

x
x
x
x
x
x
x
x
x
x
x

Firestop systems

app. kg/km

1
1
1
1
1
1
1
1
1
1
1

Distribution boxes

kg/km

186 141
186 142
186 143
186 144
186 145
186 146
186 147
186 148
186 149
186 150
186 151

Accessories

n x mm2

Information

Additional dimensions available on request.

Subject to technical modification.

75

Preventive fire protection

(N)HXH FE180 E90

Safety cables

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E90 in accordance with DIN 4102-12

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load

186 175
186 178
186 183
186 187
186 190
186 155
186 156
186 157
186 158
186 159
186 160
187 274
186 161
187 275
190 493
RE = circular, solid conductor
RM = circular, stranded conductor
Additional dimensions available on request.

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

191 069
191 002
191 003
191 004
191 005
191 006
191 008

76

Subject to technical modification.

n x mm2
3
3
3
3
3
3
3

x
x
x
x
x
x
x

35 + 1
50 + 1
70 + 1
95 + 1
120 + 1
150 + 1
185 + 1

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

16
25
35
50
70
70
95

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM

RM
RM
RM
RM
RM
RM
RM

kg/km

app. kg/km

1162
1680
2352
3216
4128
4992
6240

1833
2457
3362
4488
5532
6666
8315

app. mm
27,4
31,3
35,6
40,7
44,0
48,0
53,4

kWh/m
2,13
2,69
3,34
4,24
4,82
5,70
7,00

58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760
7104
9216

234
296
381
490
695
1089
1618
2083
2752
3804
5092
6133
7662
9425
12334

12,4
13,4
14,6
15,8
17,8
22,1
26,3
29,0
32,8
37,6
43,1
46,0
51,2
56,5
64,1

0,61
0,69
0,78
0,90
1,07
1,54
2,05
2,36
2,97
3,55
4,75
5,27
6,49
7,85
9,85

Preventive fire protection

(N)HXH FE180 E90

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E90 in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70

RE
RE
RE
RE
RE
RM
RM
RM
RM
RM

72
120
192
288
480
768
1200
1680
2400
3360

278
353
456
589
832
1361
1960
2547
3392
4667

13,4
14,5
15,8
17,2
19,3
24,8
28,8
32,0
36,5
41,5

0,71
0,81
0,93
1,05
1,25
1,86
2,42
2,86
3,68
4,51

185 271
186 180
186 185

7
7
7

x 1,5
x 2,5
x
4

RE
RE
RE

101
168
269

331
426
563

14,4
15,6
17,1

0,81
0,92
1,05

172 260
187 253

10
10

x 1,5
x 2,5

RE
RE

144
240

457
593

17,8
19,4

1,09
1,24

185 272
186 181

12
12

x 1,5
x 2,5

RE
RE

173
288

513
675

18,3
20,0

1,20
1,37

185 273
RE = circular, solid conductor
RM = circular, stranded conductor

24

x 1,5

RE

346

901

24,6

1,99

kWh/m

Information

Accessories

Additional dimensions available on request.

app. mm

Support systems

app. kg/km

5
5
5
5
5
5
5
5
5
5

Fixing devices

kg/km

186 176
186 179
186 184
186 188
186 191
186 162
186 163
186 164
186 165
187 277

Firestop systems

n x mm2

Distribution boxes

Subject to technical modification.

77

Preventive fire protection

(N)HXCH FE180 E90

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E90 in accordance with DIN 4102-12

Sheath
FRNC/LS0H

Reinforcing
helix
Bare copper tape

Insulation
Crosslinked polymer
zero halogen

Filler
Flame retardant,
zero halogen

Conductor
Solid/stranded

Fire barrier
High-peformance
Keram compound

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E90 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.

Construction

Conductor

Insulation

Filler
Concentric conductor
Separator
Outer sheath

Core colours
Sheath colour
Imprint


Bare copper, solid or stranded, IEC 60228, EN 60228,


(VDE 0295)
Double insulation, cross-linked, high-performance
Keram special compound, VDE 0266 HXI1
Halogen-free compound or plastic tape
Bare copper wires with reinforced helix
Plastic tape
Polyolefin compound, CENELEC HD 604 S1
and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Orange
Datwyler PYROFIL KERAM (N)HXCH FE180 E90 1kV N X MM2
VDE REG. NR. 7780 VDS ORDER NO. YEAR SWISS MADE
METRE MARKING
or on request

Electrical Properties

Nominal voltage
Test voltage

0.6/1kV
4000V, 50Hz

General Properties

Minimum bending radius


during and permanent installation 12 x D (multicore cable)

(D = outer diameter)
Operating temperature
permanent installation
-45C to +90C

during installation
-5C to +50C
Zero halogen,
non corrosive gases
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,

VDE 0482-332-3-22/24 Cat. A/C
Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Circuit integrity [FE/PH]
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180)

IEC 60331-1, IEC 60331-2 (120 minutes ),

EN 50200, VDE 0482-200 (PH120) and EN 50362,

VDE 0482-362 (120 minutes), BS 6387 C/W/Z
System Circuit integrity [E90] DIN 4102 part 12
System Circuit integrity
under effect of water
VdS 3423 [n x 16mm2]

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil (N)HXCH FE180/E90 Keram 0511/e

Distribution boxes
Accessories
Information

78

Separator
Plastic tape

Concentric conductor
Bare copper
wire

Subject to technical modification.

Preventive fire protection

(N)HXCH FE180 E90

Safety cable 0.6/1kV, pyrofil Keram


Halogen-free, with improved fire characteristics
With reference to VDE 0266 and CENELEC HD 604 S1
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331
System Circuit integrity E90 in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120

66
104
161
240
408
643
902
1190
1723
2410
3296
4236
5100
6383
8242

248
308
404
504
727
1166
1496
1820
2493
3350
4570
5620
6850
8350
11100

13,2
14,1
15,7
16,8
18,6
24,4
25,8
28,2
32,5
36,1
42,0
45,4
50,7
55,0
62,1

0,65
0,72
0,84
0,94
1,15
1,64
1,95
2,25
2,90
3,42
4,50
5,02
6,00
7,10
9,08

186 072
186 196
186 198
186 199
186 200
186 131
186 132
186 133
186 134
186 135
186 136
186 137
186 138
186 139
186 140

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120

81
128
200
297
504
796
1142
1526
2203
3082
4208
5388
6540
8159
10546

286
358
473
621
868
1400
1895
2376
3249
4426
5809
7134
8703
10827
14139

14,1
15,1
16,8
18,1
20,1
25,3
28,9
31,6
36,7
41,3
46,4
50,1
55,3
60,8
69,2

0,73
0,82
0,96
1,13
1,33
1,81
2,28
2,60
3,49
4,25
5,53
6,25
7,58
9,18
11,60

7
7
12
12
24
24
30
30

x
x
x
x
x
x
x
x

1,5
2,5
1,5
2,5
1,5
2,5
1,5
2,5

RE/2,5
RE/2,5
RE/2,5
RE/4
RE/6
RE/10
RE/6
RE/10

133
200
205
334
413
696
499
840

393
491
595
798
901
1205
1252
1692

16,1
17,3
20,2
22,6
27,4
30,6
29,1
32,2

0,94
1,05
1,38
1,63
2,32
2,69
2,67
3,11

186 073
191 096
187 415
172 454
187 402
187 403
187 404
187 405
RE = circular, solid conductor
RM = circular, stranded conductor
Additional dimensions available on request.

Subject to technical modification.

app. mm

kWh/m

Support systems

1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240

Fixing devices

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Firestop systems

app. kg/km

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Distribution boxes

kg/km

186 071
186 195
186 197
187 278
187 279
187 251
187 406
172 417
187 408
187 409
187 410
187 411
187 412
187 413
187 414

Accessories

n x mm2

Information

79

Preventive fire protection

JE-H(St)H...Bd FE180 E30 L

Wiring cable for industrial electronics max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30 in accordance with DIN 4102-12

Sheath
FRNC/LS0H

Shielding
Al-laminated tape
zero halogen

Drain wire
0,8 mm

Insulation
Crosslinked polymer
zero halogen

Conductor
Solid

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.

Construction

Conductor
Insulation

Core colours
Separator
Shielding
Outer sheath

Sheath colour
Imprint

Bare copper, solid, 0.8mm diameter, VDE 0815


Fire-resistant, crosslinked, high-performance Keram special
compound, EN 50290-2-26
VDE 0815, bundles identified by numbered tape
PEPT Plastic Tape
Al-laminated tape with tinned copper drain wire 0.8mm
Flame retardant polyolefin compound
VDE 0819 part 107, EN 50290-2-27 and VDE 0250-214 HM 2
Orange
Datwyler Pyrofil Keram JE-H(St)H...Bd FE180 E30 L n x 2 x mm
VDE Reg. No.9361ORDER NO. SWISS MADE metre marking
or on request

Electrical Properties

Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage

min. 100 M x km
max. 73.2 /km at 0.80 mm
max. 120 nF/km at 800 Hz
K max. 200 pF/100m at 800 Hz
max. 225 V
500 V, 50 Hz Core/Core
2000 V, 50Hz, Core/Screen

General Properties

Minimum bending radius



Crush resistance
Impact
Operating temperature

during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

System Circuit integrity [E30]

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180)
IEC 60331-2, EN 50200, VDE 0482-200
DIN 4102 part 12, NBN 713-020

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil JE-H(St)H...Bd FE180/E30- L Keram 0511/e

Distribution boxes
Accessories
Information

80

Separator
Plastic tape
zero halogen

Subject to technical modification.

7,5 x D (D = outer diameter)


2,5 x D
-30C to +70C
-5C to +50C

Preventive fire protection

JE-H(St)H...Bd FE180 E30 L

Wiring cable for industrial electronics max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30 in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load

188 376
188 318
188 325

n x mm
1
2
4

x
x
x

2
2
2

x
x
x

kg/km
0.80
0.80
0.80

15
25
45

app. kg/km
40
56
96

app. mm
5.5
6.0
8.7

kWh/m
0.095
0.123
0.21

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Additional dimensions available on request.

Subject to technical modification.

81

Preventive fire protection

JE-H(St)H...Bd FE180 E30-E90

Wiring cable for industrial electronics max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12

Sheath
FRNC/LS0H

Drain wire
0,8 mm

Conductor
Solid

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E90* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.

Construction

Conductor
Insulation

Core colours
Separator
Shielding
Outer sheath

Sheath colour
Imprint


Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage

Bare copper, solid, 0.8mm diameter, VDE 0815


Fire-resistant, crosslinked, high-performance Keram special compound,
EN 50290-2-26
VDE 0815, bundles identified by numbered tape
PEPT Plastic Tape
Al-laminated tape with tinned copper drain wire 0.8mm
Flame retardant polyolefin compound,
VDE 0819 part 107, EN 50290-2-27 and VDE 0250-214 HM 2
Orange
Datwyler Pyrofil Keram JE-H(St)H...Bd FE180 E30-E90
n x 2 x mm VDE Reg. No.9361ORDER NO. SWISS MADE
metre marking, or on request
min. 100 M x km
max. 73.2 /km at 0.80 mm
max. 120 nF/km at 800 Hz
K max. 200 pF/100m at 800 Hz
max. 225 V
500 V, 50 Hz Core/Core
2000 V, 50Hz, Core/Screen

Minimum bending radius



Crush resistance
Impact
Operating temperature

during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation

Safety cables
Fixing devices

Support systems

Application

Firestop systems

Electrical Properties

pyrofil JE-H(St)H...Bd FE180/E30-E90 Keram 0511/e

Distribution boxes
Accessories
Information

Shielding
Al-laminated tape
zero halogen

Insulation
Crosslinked polymer
zero halogen

Product information

General Properties

82

Separator
Plastic tape
zero halogen

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

System Circuit integrity
[E30-E90]*

Subject to technical modification.

7,5 x D (D = outer diameter)


2,5 x D
-30C to +70C
-5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),
IEC 60331-2, EN 50200, VDE 0482-200
DIN 4102 part 12, NBN 713-020 (Rf 11/2)
* Circuit integrity is dependent on installation method.

Preventive fire protection

JE-H(St)H...Bd FE180 E30-E90

Wiring cable for industrial electronics max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
188 092
188 097
188 099
188 102
188 104
188 106
188 108
188 111
188 113
188 115

x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x

kg/km
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80

15
25
45
85
126
166
206
326
407
529

app. kg/km
40
56
96
218
270
337
403
570
739
906

app. mm
5.5
6.0
8.7
13.7
14.6
16.0
18.0
21.8
25.3
27.6

kWh/m
0.095
0.123
0.21
0.52
0.58
0.69
0.80
1.02
1.38
1.59

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Additional dimensions available on request.

n x mm
1
2
4
8
12
16
20
32
40
52

Support systems

Subject to technical modification.

83

Preventive fire protection

JE-H(St)H...Bd FE180 E30 L

Fire alarm cable max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30 in accordance with DIN 4102-12

Separator
Plastic tape
zero halogen

Insulation
Crosslinked polymer
zero halogen

BRANDMELDEKABEL

Sheath
FRNC/LS0H

Drain wire
0,8 mm

Conductor
Solid

Application

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.

Construction

Conductor
Insulation

Core colours
Separator
Shielding
Outer sheath

Sheath colour
Imprint


Bare copper, solid, 0.8mm diameter, VDE 0815


Fire-resistant, crosslinked, high-performance Keram special compound,
EN 50290-2-26
VDE 0815, bundles identified by numbered tape
PEPT Plastic Tape
Al-laminated tape with tinned copper drain wire 0.8mm
Flame retardant polyolefin compound,
VDE 0819 part 107, EN 50290-2-27 and VDE 0250-214 HM 2
Red
Datwyler Pyrofil Keram Brandmeldekabel
JE-H(St)H...Bd FE180 E30 L n x 2 x mm
VDE Reg. No.9361 ORDER NO. SWISS MADE metre marking
or on request

Electrical Properties

Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage

min. 100 M x km
max. 73.2 /km at 0.80 mm
max. 120 nF/km at 800 Hz
K max. 200 pF/100m at 800 Hz
max. 225 V
500 V, 50 Hz Core/Core
2000 V, 50Hz, Core/Screen

General Properties

Minimum bending radius



Crush resistance
Impact
Operating temperature

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

System Circuit integrity [E30]

during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

pyrofil JE-H(St)H...Bd FE180/E30 L Keram BMK 0511/e

Distribution boxes
Accessories
Information

84

Shielding
Al-laminated tape
zero halogen

Subject to technical modification.

7,5 x D (D = outer diameter)


2,5 x D
-30C to +70C
-5C to +50C

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),
IEC 60331-2, EN 50200, VDE 0482-200
DIN 4102 part 12, NBN 713-020

Preventive fire protection

JE-H(St)H...Bd FE180 E30 L

Fire alarm cable max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30 in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load

188 377
188 374
188 375

n x mm
1
2
4

x
x
x

2
2
2

x
x
x

kg/km
0.80
0.80
0.80

15
25
45

app. kg/km
40
56
96

app. mm
5.5
6.0
8.7

kWh/m
0.095
0.123
0.21

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Additional dimensions available on request.

Subject to technical modification.

85

Preventive fire protection

JE-H(St)H...Bd FE180 E30-E90

Fire alarm cable max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12

Separator
Plastic tape
zero halogen

Insulation
Crosslinked polymer
zero halogen

BRANDMELDEKABEL

Sheath
FRNC/LS0H

Conductor
Solid

Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E90* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.

Construction

Conductor
Insulation

Core colours
Separator
Shielding
Outer sheath

Sheath colour
Imprint


Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage

Bare copper, solid, 0.8mm diameter, VDE 0815


Fire-resistant, crosslinked, high-performance Keram special compound,
EN 50290-2-26
VDE 0815, bundles identified by numbered tape
PEPT Plastic Tape
Al-laminated tape with tinned copper drain wire 0.8mm
Flame retardant polyolefin compound,
VDE 0819 part 107, EN 50290-2-27 and VDE 0250-214 HM 2
Red
Datwyler Pyrofil Keram Brandmeldekabel
JE-H(St)H...Bd FE180 E30-E90 n x 2 x mm VDE Reg. No.9361
ORDER NO. SWISS MADE metre marking, or on request
min. 100 M x km
max. 73.2 /km at 0.80 mm
max. 120 nF/km at 800 Hz
K max. 200 pF/100m at 800 Hz
max. 225 V
500 V, 50 Hz Core/Core
2000 V, 50Hz, Core/Screen

Minimum bending radius



Crush resistance
Impact
Operating temperature

during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

System Circuit integrity
[E30-E90]*

IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),
IEC 60331-2, EN 50200, VDE 0482-200
DIN 4102 part 12, NBN 713-020 (Rf 11/2)
* Circuit integrity is dependent on installation method.

Safety cables
Fixing devices

Support systems

Application

Electrical Properties

Firestop systems
pyrofil JE-H(St)H...Bd FE180/E30-E90 Keram BMK 0511/e

Distribution boxes
Accessories
Information

Drain wire
0,8 mm

Product information

General Properties

86

Shielding
Al-laminated tape
zero halogen

Subject to technical modification.

7,5 x D (D = outer diameter)


2,5 x D
-30C to +70C
-5C to +50C

Preventive fire protection

JE-H(St)H...Bd FE180 E30-E90

Fire alarm cable max. 225V, pyrofil Keram


Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
188 093
188 098
188 101
188 103
188 105
188 107
188 109
188 112
188 114
188 116

x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x

kg/km
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80

15
25
45
85
126
166
206
326
407
529

app. kg/km
40
56
96
218
270
337
403
570
739
906

app. mm
5.5
6.0
8.7
13.7
14.6
16.0
18.0
21.8
25.3
27.6

kWh/m
0.095
0.123
0.21
0.52
0.58
0.69
0.80
1.02
1.38
1.59

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Additional dimensions available on request.

n x mm
1
2
4
8
12
16
20
32
40
52

Support systems

Subject to technical modification.

87

Preventive fire protection

JE-H(St)HRH...Bd FE180 E30-E90

Fire alarm cable with steel wire braiding max. 225V, pyrofil Keram
Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12

Separator
Plastic tape
zero halogen

Insulation
Crosslinked polymer
zero halogen

BRANDMELDEKABEL

Sheath
FRNC/LS0H

Shielding
Al-laminated tape
zero halogen

Drain wire
0,8 mm

Conductor
Solid

Application

Safety cables are used in all situations that require special protection against fire and flame damage for
people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor
applications. For outdoor applications, protection must be provided against exposure to direct sunlight.
The fire alarm cables correspond to the demands of System Circuit integrity E30-E90* in accordance
with DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
The steel wire braiding serves as a form of mechanical protection. Permitted operating temperature
at conductor of +70C.

Construction

Conductor
Insulation

Core colours
Separator
Shielding
Inner sheath

Armouring
Outer sheath

Sheath colour
Imprint


Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage

Minimum bending radius

Crush resistance
Impact
Operating temperature

Zero halogen,
non corrosive gases
Flame propagation
Flame spread

Smoke density
Circuit integrity [FE/PH]

System Circuit integrity
[E30-E90]*

Fixing devices

Support systems

Safety cables

Product information

Firestop systems

Electrical Properties

Distribution boxes

General Properties

pyrofil JE-H(St)HRH...Bd FE180/E30-E90 Keram 0511/e

Accessories
Information

88

Armouring
Galvanised steel
wire braid

Subject to technical modification.

Bare copper, solid, 0.8mm diameter, VDE 0815


Fire-resistant, crosslinked, high-performance Keram
special compound, EN 50290-2-26
According to VDE 0815, bundles identified by numbered tape
PEPT Plastic Tape
Al-laminated tape with tinned copper drain wire 0.8mm
Flame retardant polyolefin compound,
VDE 0819 part 107, EN 50290-2-27 and VDE 0250-214 HM2
Galvanised steel wire braid
Flame retardant polyolefin compound,
VDE 0819 part 107, EN 50290-2-27 and VDE 0250-214 HM 2
Red
Datwyler Pyrofil Keram Brandmeldekabel JE-H(St)HRH...Bd
FE180 E30-E90 n x 2 x mm ORDER NO. SWISS MADE
metre marking, or on request
min. 100 M x km
max. 73.2 /km at 0.80 mm
max. 120 nF/km bei 800 Hz
K max. 200 pF/100m at 800 Hz
max. 225 V
500 V, 50 Hz Core/Core
2000 V, 50Hz, Core/Screen
during installation
7,5 x D (D = outer diameter)
permanent installation
2,5 x D
1000 N/10 cm
10 Impacts
permanent installation
-30C to +70C
during installation
-5C to +50C
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C,
VDE 0482-332-3-22/24 Cat. A/C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-21 (180 minutes) , VDE 0472 part 814 (FE180),
IEC 60331-2, EN 50200, VDE 0482-200
DIN 4102 part 12
* Circuit integrity is dependent on installation method.

Preventive fire protection

JE-H(St)HRH...Bd FE180 E30-E90

Fire alarm cable with steel wire braiding max. 225V, pyrofil Keram
Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12

Safety cables

Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load

188 119
188 120
188 127
188 128

188 129
188 346

x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x

kg/km
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80

15
25
45
85
126
166
206
326

app. kg/km
94
117
179
404
466
550
640
877

app. mm
8.3
9.0
11.7
18.0
18.9
20.3
22.3
26.5

kWh/m
0.23
0.26
0.39
0.93
1.01
1.16
1.32
1.72

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Additional dimensions available on request.

n x mm
1
2
4
8
12
16
20
32

Support systems

Subject to technical modification.

89

Preventive fire protection

ZGGFR-Safety / U-DQ(ZN)BH

Safety cable for indoor and outdoor use


nonmetallic, water resistant, rodent protected, flame redardant
in accordance with IEC 60332.1 and IEC 60332.3-24 Cat. C
functional integrity with reference to DIN 4102-12 30Min. (E30)
ripcord

FR/LS0H sheath

12 fibres

flame retardant
protective coatings

Features

Fibre-optic safety cable in metal-free central tube design with up to twelve fibres.
The optimum matching of fibre coating and flame-inhibiting stabilizing elements
ensures functional integrity for 30 minutes.

Application

Safety applications in tunnels, underground railways,


banks, insurance companies, large scale industry
LAN backbones
Indoor and outdoor use
Can be laid on cable platforms, parapet ducts and vertical shafts
Can be spliced in cable terminal distributors

Optical characteristics

The cables are available with different types of Optofil-Safety fibre (see fibre data sheets)

Mechanical
characteristics

temperature range


tensile performance
crush resistance
repeated bending
torsion
bend
water penetration

storage
-25 / +70C
pulling in
-10 / +50C
operation
-25 / +60C
IEC 60794-1-2 E1
IEC 60794-1-2 E3
IEC 60794-1-2 E6
IEC 60794-1-2 E7
IEC 60794-1-2 E11
IEC 60794-1-2 F5

General characteristics

Printing example

DTWYLER OPTOFIL SAFETY 12E9 G.652D FR/LSOH DIN 4102-12 (30)

IEC 60331-25 (180)


C-no. 10865 ~
~ 2480 m ~

Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity

System Circuit integrity
[E30]*

IEC 60754-1/-2, EN 50267-2-1/-2-2, VDE 0482-267-2-1/-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-24 Cat.C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat.C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-25 (180 minutes) , VDE 0472 part 814,
EN 50200, VDE 0482-200
with reference to DIN 4102 part 12
*Circuit integrity is dependent on installation method.

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

GF-1323 ZGGFR-Safety 1108/e

Accessories
Information

90

glass armouring

Subject to technical modification.

IEC 60794-1-2 F1

~ SWISS MADE

Preventive fire protection

ZGGFR-Safety / U-DQ(ZN)BH

Safety cable for indoor and outdoor use


nonmetallic, water resistant, rodent protected, flame redardant
in accordance with IEC 60332.1 and IEC 60332.3-24 Cat. C
functional integrity with reference to DIN 4102-12 30Min. (E30)

Safety cables

Product information
loose tube

cable

max.

max.

mm

kg/km

mm

12

7.8

72

120

1000

ZGGFR-Safety

1x12

weight bending radius tensile load crush resistance Fire load


continuous N/cm short term N/cm kWh/km MJ/km
200

500

301 1084

Versions
U-DQ(ZN)BH 1xm

fibre Article No. Article No. Article No. Article No.

description

numbe

E9/125 G.652.D

G50/125 OM2

G50/125 OM3

G62.5/125 OM1

ZGGFR-Safety

187 288

186 363

190 604

186 638

1x4
1x6

191 867

186 639

191 851

190 792

1x8

on request

190 621

on request

on request

ZGGFR-Safety

1x12

12

190 719

187 293

191 796

187 305

Information

Accessories

Distribution boxes

Firestop systems

ZGGFR-Safety
ZGGFR-Safety

Support systems

no. of fibres

U-DQ(ZN)BH 1xm

Fixing devices

description

Subject to technical modification.

91

Preventive fire protection

wbGGFR-Safety / U-DQ(ZN)BH

Safety cable for indoor and outdoor use


nonmetallic, water resistant, rodent protected, flame redardant
in accordance with IEC 60332.1 and IEC 60332.3-24 Cat. C
functional integrity with reference to DIN 4102-12 30Min. (E30)
ripcord

FR/LS0H sheath

glass armouring

Features

Fibre-optic safety cable in metal-free central tube design with up to twelve fibres.
The optimum matching of fibre coating and flame-inhibiting stabilizing elements
ensures functional integrity for 30 minutes.

Application

Safety applications in tunnels, underground railways,


banks, insurance companies, large scale industry
LAN backbones
Indoor and outdoor use
Can be laid on cable platforms, parapet ducts and vertical shafts
Can be spliced in cable terminal distributors

Optical characteristics

The cables are available with different types of Optofil-Safety fibre (see fibre data sheets)

Mechanical
characteristics

temperature range


tensile performance
crush resistance
repeated bending
torsion
bend
water penetration

storage
-25 / +70C
pulling in
-10 / +50C
operation
-25 / +60C
IEC 60794-1-2 E1
IEC 60794-1-2 E3
IEC 60794-1-2 E6
IEC 60794-1-2 E7
IEC 60794-1-2 E11
IEC 60794-1-2 F5

General characteristics

Printing example


DTWYLER OPTOFIL SAFETY 60E9 G.652D FR/LSOH DIN 4102-12 (30)

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Product information

Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity

System Circuit integrity
[E30]*

GF-1324 optofil-wbGGFR-Safety 1108/e

Information

Accessories

92

12 fibres

flame retardant
protective coatings

Subject to technical modification.

IEC 60331-25 (180)


C-no. 10865 ~
~ 2480 m ~

IEC 60794-1-2 F1

~ SWISS MADE

IEC 60754-1/-2, EN 50267-2-1/-2-2, VDE 0482-267-2-1/-2-2


IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
IEC 60332-3-24 Cat.C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat.C
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
IEC 60331-11/-25 (180 minutes) , VDE 0472 part 814,
EN 50200, VDE 0482-200
with reference to DIN 4102 part 12
*Circuit integrity is dependent on installation method.

Preventive fire protection

wbGGFR-Safety / U-DQ(ZN)BH

Safety cable for indoor and outdoor use


nonmetallic, water resistant, rodent protected, flame redardant
in accordance with IEC 60332.1 and IEC 60332.3-24 Cat. C
functional integrity with reference to DIN 4102-12 30Min. (E30)

Safety cables

Product information
loose tube

cable

max.

max.

mm

weight bending radius tensile load crush resistance Fire load


kg/km

mm

wbGGFR-Safety

2x12

24

12.5

166

190

6000

continuous N/cm short term N/cm kWh/km MJ/km


300

500

733 2639

wbGGFR-Safety

3x12

36

12.5

168

190

6000

300

500

733 2639

wbGGFR-Safety

4x12

48

12.5

170

190

6000

300

500

733 2639

wbGGFR-Safety

5x12

60

12.5

166

190

6000

300

500

733 2639

Versions
fibre Article No. Article No. Article No. Article No.

description

number

E9/125 G.652.D

G50/125 OM2

G50/125 OM3

G62.5/125 OM1

wbGGFR-Safety

2 x 12

24

190 223

187 294

187 360

on request

wbGGFR-Safety

3 x 12

36

190 224

on request

on request

on request

wbGGFR-Safety

4 x 12

48

190 225

192 119

191 191

on request

wbGGFR-Safety

5 x 12

60

190 226

on request

190 605

on request

Information

Accessories

Distribution boxes

Firestop systems

U-DQ(ZN)BH nxm

Support systems

no. of fibres

U-DQ(ZN)BH nxm

Fixing devices

description

Subject to technical modification.

93

Product information
Application

Cable duct system for exposure to fire from inside to outside, for prevention of fire propagation
on cabling systems in floors and stairwells.
Installation with screw set directly onto multi cable support (Hermann clamp).
Spacing of fixation 600 mm.

Technical Data

Material
Colour
Approvals
Dimensions

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Preventive fire protection


Cable duct I30 (Hermannkanal)
HSK I 30

Cable duct I30 (Hermannkanal) with installation set


(1-3 pcs. multi cable support/Hermann clamp and fire safety plug KDM 30 mm).
Drill and installation tools are not included.
Recommended drill SDS 1, recommended installation tool SWM-SM 50.
Article No. Type Info PU
1301 158

HSK I 30/1200

L=

1200 mm

1 Set

1301 159

HSK I 30/600

L=

600 mm

1 Set

1301 160

HSK I 30/400

L=

400 mm

1301 161

HSK I 30/B90

90 right-hand angle

1301 164

HSK I 30/B90

90 left-hand angle

1 Set

HSK I 30/B45

45 right-hand angle

1 Set

45 left-hand angle

1 Set

1301 163

HSK I 30/B45

1301 167

HSK I 30/Cross

1 Set

1301 166

HSK I 30/T joint

1 Set

1301 157

HSK I 30/End part

1 Piece

Accessories
Additional multi cable support (Hermann clamp) for I30 duct (Hermannkanal)
Article No. Type Info PU

Accessories

SHUD

Hermann clamp

10

Fire protection paint


Article No. Type Info PU
1300 465

Information

1 Set
1 Set

1301 162

1300 964

94

Light construction fire protection plate


White, impregnated
ABP No.: P-3015 / 6930 MPA BS
Outside (W x H): 170 x 195 mm
Inside:
120 x 170 mm

pyroplast-S 100 D

Fire protection paint

15 kg plastic bucket

Fire protection filler


Article No. Type Info PU
1300 467

Subject to technical modification.

pyroplast-S 100 SM-K

Fire protection filler

10 cartridges/310ml

Preventive fire protection

WUM
Support measure

For vertical cable installation

Safety cables

Product information
Effective support measure for vertical installation of pyrofil cables with circuit integrity
in accordance with DIN 4102-12, using the C-shaped rail 2970 SLD.
Meandering cable laying is not necessary if the WUM is used at intervals of up to 3.5 m.

Goods supplied

Fire protection housing


Fastening set
Fire protection filler S 100 SM-K
Mineral wool

Note

The WUM E30 and E90 can be used with all pyrofil Keram cable types
(N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90,
JE-H(St)H FE180/E30-E90 and JE-H(St)HRH FE180/E30-E90.

Function

The WUM protects the clamp of pyrofil safety cables with circuit integrity,
thereby supporting the vertical cabling system in the event of fire.

Installation

The WUM is slipped over the strap clamp that attaches the cable to the C-shaped rail
at intervals of up to 3.5 m. It is attached to the C-shaped rail by means of slide nuts and threaded
rods.Hollow spaces are filled with mineral wool. The cable inlet and back of the WUM
are sealed with pyroplast fire protection filler S 100 SM-K.

for C-shaped rail 2970 SLD PU

width mm

mm

1301 276

WUM 300 E30

100 x 370 x 135

300

1301 278

WUM 400 E30

100 x 470 x 135

400

1301 277

WUM 500 E30

100 x 570 x 135

500

1301 275

WUM 300 E90

200 x 470 x 185

300

1301 274

WUM 400 E90

200 x 570 x 185

400

1301 273

WUM 500 E90

200 x 670 x 185

500

Subject to technical modification.

Information

Article No. Type Outer dimensions

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Application

95

Preventive fire protection

Fixing devices

Support systems

Safety cables

Wire mesh cable tray

Product information
Application

For laying single and multiple cables under ceilings or on walls.


Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60.
Maximum permissible fixing distance up to 1250mm. Max. load - 10 kg/m

Technical Data

Material
Corrosion protection


Approvals

Steel wire, mesh 50x100mm, flange height 54mm,


Galavanised (electrolytic) in accordance with DIN 50961
(zinc layer 18-20 ).
Others on request
VDE 0639, CEI 1537

Wire mesh cable tray


Article No. Type Nominal width [mm]

kg/m PU

1300 999

GR 54-100

100

1,29

3m

1301 078

GR 54-150

150

1,53

3m

1301 079

GR 54-200

200

1,77

3m

Firestop systems

Note: For cutting, a bolt cutter with offset cutting has to be used.
Ceiling console, screwless
Corrosion protection: Sendzimir galvanised in accordance with DIN 17162 (zinc coating app. 21).
Other on request
for

kg/piece PU

Distribution boxes

Height x width [mm]

1301 080

GR DKS 150

app. 210 x 230

GR 54-100

0,68

1301 081

GR DKS 200

app. 210 x 280

GR 54-150

0,75

1301 082

GR DKS 300

app. 210 x 380

GR 54-200

0,87

Accessories

Article No. Type

Wall console, screwless


Corrosion protection: Sendzimir galvanised in accordance with DIN 17162 (zinc coating app. 21).
Other on request

Information

Article No. Type

96

for

kg/piece PU

1301 083

GR WKS 150

app. 170 x 230

GR 54-100

0,46

1301 084

GR WKS 200

app. 170 x 280

GR 54-150

0,52

1301 085

GR WKS 300

app. 170 x 380

GR 54-200

0,64

Subject to technical modification.

Height x width [mm]

Preventive fire protection

Wire mesh cable tray


Accessories

Safety cables

Product information
Wire mesh cable tray accessories
Article No. Type Description Info

Contents: 50 push connectors ED 275


50 Snap connectors KITASSTR

For each push connection provided:

- 10 pcs KITASSTR

- 2 pcs ED 275

for 90 angles

For each 90 angle for barred groove 100 provided:


- 6 pcs KITASSTR

- 1,5 pcs ED 275

For each 90 angle for barred groove 150/200 provided:

- 8 pcs KITASSTR

- 2 pcs ED 275

for T-junctions

For each T-junction for a barred groove provided:

- 4 pcs KITASSTR

For each T-junction for a barred groove provided:

for cross joints

- 6 pcs KITASSTR

- 2 pcs ED 275

Wire mesh cable tray fixings


Article No. Type Description Info
1301 096

GAS 8x220 Thread suspension

set M8x220

For thread attachment to ceiling console GR DKS


Contents:

13 thread rails M8x1000, 50 KMu LF8 plugs,

100 underlay disks, nuts M8

(recommended tool set SMu 8 SM, drillbit SDS2)

1301 097

For thread attachment to wall console GR WKS

GS 8x1000 Thread rod


1301 098

M8x1000

GZS Thread rod

Support systems

for straight joints

Fixing devices

Firestop systems

ED 275 and KITASSTR

PU 50 pieces

Distribution boxes

GR VB

Accessories for thread rod suspension attachment

attachment

GS 8x1000

accessories

Contents:
100 underlay disks

M8 nuts, KMu LF8 plugs,

(recommended tool set SMu 8 SM, drillbit SDS2)


Information

Accessories

1301 090

Subject to technical modification.

97

Preventive fire protection

Cable tray

Safety cables

without threaded rod suspension

Product information
Application

For laying single and multiple cables under ceilings or on walls.


Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60,
(N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90.
This cable tray system needs no threaded rod suspensions for circuit integrity.
Maximum permissible fixing distance up to 1500 mm. Max. load - 20 kg/m.

Support systems

Technical Data

Material
Nominal size

Steel galavanised
60 x 100 mm, 60 x 200 mm, 60 x 300 mm, 60 x 400 mm

Cable tray

Firestop systems

Fixing devices

Article No. Type Nominal size PU


3800 032

RG 60-10S

100 mm

1 piece = 3 m

3800 033

RG 60-20S

200 mm

1 piece = 3 m

3800 129

RG 60-20S 45 angle

200 mm

1 piece

3800 034

RG 60-30S

300 mm

1 piece = 3 m

3800 035

RG 60-40S

400 mm

1 piece = 3 m

60 RGV-BS 60S

60 mm

1 piece

Lateral connector
3800 036

Accessories

Distribution boxes

Bottom connector
3800 038

VB-BS 10S

100 mm

1 piece

3800 039

VB-BS 20S

200 mm

1 piece

3800 044

VB-BS 30S

300 mm

1 piece

3800 045

VB-BS 40S

400 mm

1 piece

M6

100 pieces

Screws for fixing the tray on the console


3800 040

screw set KLAR

Information

Lateral reinforcement in the area of consols

98

3800 041

Subject to technical modification.

ALS-BS S

1 piece

Preventive fire protection

Cable tray

Safety cables

Product information
Plugs
Article No. Type Nominal size PU
3800 077

M10x10 SD 10/10

M10x10

100 pieces

3800 042

KWMS 010F

100 mm

1 piece

3800 043

KWMS 020F

200 mm

1 piece

3800 047

KWMS 030F

300 mm

1 piece

3800 048

KWMS 040F

400 mm

1 piece

Support systems

Wall consoles

100 mm

1 piece

200 mm

1 piece

3800 051

KUMS 030F

300 mm

1 piece

3800 053

KUMS 040F

400 mm

1 piece

Hangers
KDU 52-03F

300 mm

1 piece

KDU 52-04F

400 mm

1 piece

3800 056

KDU 52-05F

500 mm

1 piece

3800 057

KDU 52-06F

600 mm

1 piece

3800 058

KDU 52-07F

700 mm

1 piece

3800 059

KDU 52-08F

800 mm

1 piece

3800 060

KDU 52-09F

900 mm

1 piece

3800 061

KDU 52-10F

1000 mm

1 piece

Accessories

3800 054
3800 055

Firestop systems

KUMS 010F
KUMS 020F

Distribution boxes

3800 049
3800 050

Fixing devices

Consoles for hangers

Accessories to fix the consoles on hangers


ring washer US 10x21

M10x21

100 pieces

nut SEM 10

M10

100 pieces

3800 074

screw KLS 10x20

M10x20

100 pieces
Information

3800 072
3800 073

Subject to technical modification.

99

Preventive fire protection

Single clamp

Type SAS
Fixing distance 600 mm

Safety cables

Fig.1: Type SAS single clamp

Fig.2: Type SAS pre-assembled single clamp



with fire protection plugs type K6x5

Product information
Application

For laying single and multiple cables on ceilings or walls. Circuit integrity is achieved for
pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90,
JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90.

Type SAS (Fig.1)

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Article No. Clamp type Cable- [mm] PU


1300 016

SAS

100 pcs.

1300 017

SAS

100 pcs.

1300 018

SAS

10

10

100 pcs.

1300 019

SAS

12

11

12

100 pcs.

1300 020

SAS

14

13

14

100 pcs.

1300 021

SAS

16

15

16

100 pcs.

1300 022

SAS

18

17

18

100 pcs.

1300 023

SAS

20

19

20

100 pcs.

1300 024

SAS

22

21

22

100 pcs.

1300 025

SAS

24

23

24

100 pcs.

1300 026

SAS

26

25

26

100 pcs.

1300 027

SAS

28

27

28

100 pcs.

1300 028

SAS

30

29

30

100 pcs.

1300 251

SAS

38

new

29

38

25 pcs.

1300 252

SAS

47

new

38

47

20 pcs.

1300 234

SAS

55

new

47

55

20 pcs.

1300 250

SAS

60

new

55

60

20 pcs.

To attach the single clamp, we recommend the use of Datwyler fire protection plugs K6x5 and the Datwyler tool set SMu 6 SM for quick assembly.

Type SAS pre-assembled single clamp with fire protection plugs type K6x5, 30 mm (Fig.2)
1300 956

SAS

- K6x5

100 pcs.

1300 957

SAS

12

K6x5

11

12

100 pcs.

1300 958

SAS

14

K6x5

13

- 14

100 pcs.

1300 959

SAS

16

K6x5

15

- 16

100 pcs.

Required tool set SMu 6 SM. The required SDS1 32 mm drillbit is included in the set.

Type SAS V4A steel grade 1.4571 (simillar to Fig.1) (ask also for stainless steel plugs)

SAS

19

V4A

15

19

50 pcs.

SAS

24

V4A

20

24

50 pcs.

SAS

29

V4A

25

- 29

50 pcs.

SAS

38

V4A

30

- 38

25 pcs.

SAS

47

V4A

39

- 47

20 pcs.

SAS

55

V4A

48

- 55

20 pcs.

SAS

63

V4A

56

- 63

20 pcs.

Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc.

100

Subject to technical modification.

Preventive fire protection

Strap clamp

Type B without trough (LW)


Fixing distance - 800 mm

C-shaped rail 2970/2SLD

Type B strap clamp without trough

Application

Safety cables

Product information
For laying several cables independently in parallel on ceilings and walls.
Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60,
(N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90.

12

100 pcs.

14

100 pcs.

1300 045

16

12

16

100 pcs.

1300 046

18

14

18

100 pcs.

1300 047

22

18

22

100 pcs.

1300 048

26

22

26

100 pcs.

1300 049

30

26

30

100 pcs.

1300 050

34

30

34

100 pcs.

1300 051

38

34

38

100 pcs.

1300 052

42

38

42

100 pcs.

1300 053

46

42

46

100 pcs.

1300 054

50

46

50

50 pcs.

1300 055

54

50

54

50 pcs.

1300 056

58

54

58

50 pcs.

1300 057

64

58

64

50 pcs.

1300 058

70

64

70

50 pcs.

1300 059

76

70

76

50 pcs.

1300 060

82

76

82

50 pcs.

1300 061

90

82

90

50 pcs.

1300 062

100

90

100

25 pcs.

1300 063

110

100

110

25 pcs.

The C-shaped rail 2970/2 SLD is required to fix the strap clamps.
Article No. C-shaped rail

Slit width PU

1300 064

2970/2 SLD

16 mm

For assembly of the C-shaped rail, we recommend fire protection plugs KDM, 30 mm.
Do not exceed the maximum tensile force on the fire protection plugs!
Shaped rails come in 2 m lengths. Other lengths are available on request.

For fast assembly of the shaped rail, we recommend the tool set SWM-SM.

Please also see our optional installation methods:


Installation of cable bundles in clamps, installation in steel armoured conduits, etc.

Subject to technical modification.

as required

Fixing devices

10

Firestop systems

Distribution boxes

14

Accessories

12

Information

1300 044

Support systems

Article No. Clamp type Cable [mm] PU


1300 043

101

Preventive fire protection

Strap clamp

Type B with trough (LW)


Fixing distance 800 mm

Safety cables

Type B strap clamp with trough

C-shaped rail 2970/2SLD

Product information
Application

For laying several cables independently or in bundles in parallel on ceilings and walls.
Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60,
(N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90
(800 mm).

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Article No. Clamp type Cable [mm] PU

102

1300 045

16

100 pcs.

1300 065

LW

16

8 13

100 pcs.

1300 047

22

100 pcs.

1300 066

LW

22

13 19

100 pcs.

1300 048

26

100 pcs.

1300 067

LW

26

19 23

100 pcs.

1300 050

34

100 pcs.

1300 068

LW

34

23 31

100 pcs.

1300 051

38

100 pcs.

1300 069

LW

38

31 36

100 pcs.

1300 052

42

100 pcs.

1300 070

LW

42

36 40

100 pcs.

1300 053

46

100 pcs.

1300 071

LW

46

40 43

100 pcs.

1300 054

50

50 pcs.

1300 072

LW

50

43 47

50 pcs.

1300 055

54

50 pcs.

1300 073

LW

54

50 pcs.

47 51

The C-shaped rail 2970/2 SLD is required to fix the strap clamps.
Article No.

Shaped rail

1300 064

2970/2 SLD

Slit width PU
16 mm

as required

For assembly of the C-shaped rail, we recommend fire protection plugs KDM, 30 mm.
Do not exceed the maximum tensile force on the fire protection plugs!
Shaped rails come in 2 m lengths. Other lengths are available on request.

For fast assembly of the shaped rail, we recommend the Datwyler tool set SWM-SM.

Please also see our optional installation methods:


Installation of cable bundles in clamps, installation in steel armoured conduits, etc.

Subject to technical modification.

Preventive fire protection

Multi cable support E30-E90


Hermann clamp for wall
and ceiling installation
Fixing distance 800 mm / 600 mm*

Multi cable support E30-E90


Type Hermann clamp S

Safety cables

Product information
Application

For laying multiple cables on ceilings or walls. Circuit integrity is achieved for pyrofil Keram
cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90,
JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90.

Goods supplied

Article No. 1300 964 and Article No. 1301 280


Set consists of 10 SHUD multi cable supports (Hermann clamps),
including 10 fire protection plugs KDM, 30 mm.

Support systems

Drill bit and tool set supplied separately. Recommended drill bit SDS1,
recommended tool set SWM-SM 50.
Article No. 1301 240
Stainless steel plugs on request.

Material
Inner dimensions
Outer dimensions
Maximum load
Fixing distance

Hermann clamp
Sendzimir galvanised sheet
app. 110 mm x 75mm x 80mm
app. 125 mm x 95mm x 80mm
6 kg/m or 3 kg/m*
800 mm or 600 mm*

Hermann clamp S
Sendzimir galvanised sheet
app. 70 mm x 52 mm x 56 mm
app. 84 mm x 73 mm x 56 mm
3 kg/m*
800 mm or 600 mm*

Firestop systems

Technical Data

Fixing devices

Multi cable support E30-E90


Type Hermann clamp

10 pieces
750 pieces/skeleton box

1301 280

Hermann clamp S

10 pieces

1301 279

Hermann clamp S

1750 pieces/skeleton box

1301 240

Hermann clamp V2A (1.4301)

10 pieces

3800 156

Hermann clamp V4A (1.4571)

10 pieces

3800 157

Hermann clamp S V4A (1.4571)

10 pieces

For quick assembly of the SHUD Hermann clamp


we recommend the tool set SWM-SM 50.

*Please also see our optional installation methods:


Installation of cable bundles in clamps, installation in steel armoured conduits, etc.

Subject to technical modification.

Accessories

Hermann clamp
Hermann clamp

Information

1300 964
1300 346

Distribution boxes

Article No. Clamp type PU

103

Preventive fire protection

Firestop systems

Safety cables

End coated mineral fibre plate MFP

Product information
Application

Support systems

Identification sign

Used to form a bulkhead for cable wall and ceiling penetration


against the effects of fire for a period of 90 minutes in accordance with DIN 4102-9
(fire resistance class S90/S120).

Article No. Bulkhead Application Info


1300 464

Mineral fibre plate

For provision of a S90

pyroplast-S 100 P

bulkhead in ceilings and

Set consists of 5 plates

walls in accordance with DIN 4102-9

(Dimensions: 5 x 0.3 m2)


301 371

Fire protection paint

For coating mineral-

15 kg plastic bucket white,

fibre plates and technical

with carry handle

cables on bulkhead exit

water-based, solvent free

301 370

Fire protection filler

For closing gaps

5 kg plastic bucket, white,

pyroplast-S 100 SM

and cracks and wall

with carry handle

soffits

water-based, solvent free

1300 467

Fire protection filler

For finishing off

310 ml cartridge, white

pyroplast-S 100 SM-K

gaps and cracks

Set consists of 12 cartridges

and wall soffits

water-based, solvent free

1300 478

Identification sign

For permanent identification

Set consists of

for flat bulkhead

of a cable bulkhead

10 identification signs

Information

104

in box = 1.5 m2

pyroplast-S 100 D

Accessories

Distribution boxes

Firestop systems

Fixing devices

Single-side end coated

Subject to technical modification.

in accordance with DIN 4102-9

Preventive fire protection

Firestop systems

Plugs / Accessories

Identification sign

Application

Safety cables

Product information
Used to form a bulkhead for cable wall and ceiling penetration
against the effects of fire for a period of 90 minutes in accordance
with DIN 4102-9 (fire resistance class S90).

Fire protection plug

For provision of a round

Packaging comprises 20 pieces

BDS

S90 bulkhead in ceilings and

For bore holes up to 65 mm

walls in accordance with DIN 4102-9

Dry and dust-free assembly,

problem free installation


1300 471

Fire protection plug

For provision of a round

Packaging comprises 20 pieces

BDS

S90 bulkhead in ceilings and

For bore holes up to 78 mm

walls in accordance with DIN 4102-9

Dry and dust-free assembly,

Support systems

Article No. Bulkhead Application Info


1300 470

Packaging comprises 20 pieces


For bore holes up to 108 mm

walls in accordance with DIN 4102-9

dry and dust-free assembly,

1300 473

Fire protection plug

For provision of a round

Packaging comprises 20 pieces

BDS

S90 bulkhead in ceilings and

For bore holes up to 123 mm

walls in accordance with DIN 4102-9

Dry and dust-free assembly,

problem free installation


1300 474

Fire protection plug

For provision of a round

Packaging comprises 20 pieces

BDS

S90 bulkhead in ceilings and

For bore holes up to 135 mm

walls in accordance with DIN 4102-9

Dry and dust-free assembly,

problem free installation


1300 475

Fire protection plug

For provision of a round

Packaging comprises 20 pieces

BDS

S90 bulkhead in ceilings and

For bore holes up to 165 mm

walls in accordance with DIN 4102-9

Dry and dust-free assembly,

problem free installation


1300 476

Fire protection plug

For provision of a round

Packaging comprises 20 pieces

BDS

S90 bulkhead in ceilings and

For bore holes up to 200 mm

walls in accordance with DIN 4102-9

Dry and dust-free assembly,

problem free installation


1300 477

Fire protection block

For closing gaps

Set consists of 12 cartridges

BDS-N (1K)

and spandrels and

at 310 ml each, white

wall soffits

1300 478

Identification sign

For permanent identification

Set consists of 10

Fire protection plug

of a cable bulkhead

Identification signs

Fire protection brick

in accordance with DIN 4102-9

Subject to technical modification.

Information

problem free installation

Firestop systems

For provision of a round


S90 bulkhead in ceilings and

Distribution boxes

Fire protection plug


BDS

Accessories

1300 472

Fixing devices

problem free installation

105

Preventive fire protection

Cable joint E30/E90

Product information
Application

For connection of two pyrofil Keram cable types (N)HXH/(N)HXH CL/(N)HXCH FE180/E30-E60,
(N)HXH/(N)HXCH FE180/E90.
The cable joint provides the relevant circuit integrity of the cables.

Goods supplied

Full shrink tube, without squeeze connections.

Construction

The joint consist of several heat-absorbing inner joints (depending on the number of conductor
connections), an external joint and several insulating tubes that act as a flame barrier.

Assembly

Cables are prepared as usual, with offset connection order.


The connection joint is installed using any common warm air device.
Detailed assembly instructions are provided with each joint.
Mandrel crimping is not permitted for crimped connections.

Fixing devices

Support systems

Safety cables

Cable joint E30-E90

Distribution boxes

Firestop systems

For Datwyler pyrofil Keram types (N)HXCH with concentric conductor


Article No. Dimensions Description
1300 310

from

1,5 mm2 up to

4 mm2

joint SMH4

1300 311

from

6 mm2 up to

10 mm2

joint SMH4

1300 312

from

16 mm2 up to

25 mm2

joint SMH4

1300 313

from

35 mm2 up to

50 mm2

joint SMH4

1300 314

from

70 mm2 up to

95 mm2

joint SMH4

1300 315

from

120 mm2 up to

150 mm2

joint SMH4

1300 316

from

185 mm2 up to

240 mm2

joint SMH4

1300 317

from

1,5/1,5 mm2 up to

4/4 mm2

joint SMHC4

1300 318

from

6/6 mm2 up to

10/10 mm2

joint SMHC4

1300 319

from

16/16 mm2 up to

25/16 mm2

joint SMHC4

1300 320

from

35/16 mm2 up to

50/25 mm2

joint SMHC4

1300 321

from

70/35 mm2 up to

95/50 mm2

joint SMHC4

Information

Accessories

For Datwyler pyrofil Keram types (N)HXH-O 4-conductor- or NHXH-J 5-conductor cables

1300 322

from

120/70 mm2 up to

150/70 mm2

joint SMHC4

1300 323

from

185/95 mm2 up to 240/120 mm2

joint SMHC4

106

Subject to technical modification.

Preventive fire protection

Distribution box E30-E90


Type Hercules distribution box

Hercules distribution box E30-E90

Hercules cover
AHD E30-E90

Safety cables

Product information
Application

Terminal box or cover for power current and low current in accordance with DIN 4102-12
to protect commercial distribution, branch boxes and sub-distribution boxes against the effects
of fire for a period of 30 or 90 minutes (circuit integrity class E30 or E90), e.g. emergency lighting,
alarm circuits and fire announcement systems, fire alarm systems, etc.

Goods supplied

Hercules cover box E30-E90 Typ AHD...


incl. mounting angles, screws, cartridge of fire protection filler SP S 100 SM-K

Support systems

Hercules distribution box E30-E90 Typ HS... (Power current distribution box)
incl. mounting screws, cartridge of fire protection filler S 100 SM-K
top hat rail 35x7,5x250 mm.

Function

Connections and branches of power current and low current.


Please note that due to the selectivity of safety circuits or in the case of a decrease in cross section,
a corresponding circuit breaker must be installed.

Installation

The time required for assembly of the E30-E90 Hercules distribution box or cover is around 10
minutes. The screws are screwed into a predrilled hole without plugs. The cable inlets and outlets
are sealed with the pyroplast S 100 SM-K fire protection filler. The cables do not not need to be tied.

Article No. Type Outer dimensions (mm) Inner dimensions (mm)


Hercules cover AHD E30-E90

301 382

AHD 263013 E90

Hercules distribution box E30-E90 with top hat rail

301 375

HS 263013 E90

301 376

HS 353013 E90

301 377

HS 523013 E90

340 x 380 x 220

top hat rail / frame PU

260 x 300 x 130

(empty without base)

1 pc.

340 x 380 x 220

260 x 300 x 130

35 x 7,5 1-row

1 pc.

430 x 380 x 220

350 x 300 x 130

35 x 7,5 2-rows

1 pc.

600 x 380 x 220

520 x 300 x 130

35 x 7,5, 3-rows

1 pc.

Distribution boxes

The Hercules distribution box or cover E30-E90 can be used for all pyrofil Keram cable types
(N)HXH/(N)HXCH FE 180/E30-E60, (N)HXH/(N)HXCH FE 180/E90,
JE-H(ST)H FE180/E30-E90/ JE-H(ST)HRH FE180/E30-E90.

Accessories

Note

Firestop systems

Fixing devices

Hercules distribution box E30-E90 Typ HI... (Low current distribution box)
incl. mounting screws, cartridge of fire protection filler S 100 SM-K
QSA back mount frame ... x 105 x 50 mm.
(Quante: depth 30 mm, pitch: 27,5 mm)

Hercules distribution box E30-E90 with QSA trough

301 378

HI 263013 E90

340 x 380 x 220

260 x 300 x 130

156 x 105 x 50 (6 strips)

1 pc.

301 379

HI 353013 E90

430 x 380 x 220

350 x 300 x 130

291 x 105 x 50 (11 strips)

1 pc.

301 380

HI 523013 E90

600 x 380 x 220

520 x 300 x 130

359 x 105 x 50 (13 strips)

1 pc.

Subject to technical modification.

Information

107

Preventive fire protection

Connection / terminal box


E30-E90

VAD E30 - E90

Product information
Application

Connection / terminal box. Tested on the basis of DIN 4102-12,


circuit integrity class E30.

Goods supplied

Halogen-free plastic box, cable glands, ceramic clamps, mounting rail and fire protection plugs.

Technical Data

Material
Colour
Protection class

Accessories

Fuse element for VAD 2

Technical Data

AC 230V fuse holder 5 x 20 mm with 2A fuse.

Halogen-free special compound, fail-safe


Orange
IP 54

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

Fuse element for VAD 2

Connection / terminal box VAD E30 E90


Article No. Type Outer dimensions (mm) Dimensions
301 372

VAD 2 5x6 E30-E90

100 x 100 x 50

5 x 0,5-6 mm

301 373

VAD 2 3x10 E30-E90

100 x 100 x 50

3 x 1,5-10 mm2

301 381

VAD 2 8x6 E30-E90

165 x 165 x 76

8 x 0,5-6 mm2

for branches up to PU
1,5 mm2

1 pc.

4 mm2

1 pc.

1,5 mm2

1 pc.

Accessories

Information

Article No. Description/Accessorie Dimensions (mm) PU


LxWxH

660 301

40 x 20 x 20

108

Subject to technical modification.

AC 230V-Fuseholder 5 x 20 mm

1 pc.

Preventive fire protection

Distribution box E30

AD E30

Application

Branch, connection or terminal box. Tested on the basis of DIN 4102-12,


circuit integrity class E30.
Distribution box for emergency lighting or alarm systems.
Connection box e.g. for smoke and heat extraction systems in damp areas
(underground car parks, industry, etc.)

Goods supplied

Box and mounting rail for feedthrough terminals.


Cable glands on request.

Technical Data

Material
Systems test
Wiring assembly
Cable inlets
Colour
Protection class

Support systems

Safety cables

Product information

Distribution box AD E30


Article No. Type Outer dimensions (mm) Dimensions PU
AD E30

130 x 130 x 108

2.5 - 6 mm2

1 pc.

AD E30

160 x 160 x 108

2.5 - 6 mm2

1 pc.

on request

AD E30

200 x 200 x 108

2.5 - 6 mm2

1 pc.

on request

AD E30

200 x 400 x 108 (twin-box, 6 inlets)

2.5 - 6 mm2

1 pc.
Information

on request
on request

Accessories

Distribution boxes

Firestop systems

Fixing devices

Halogen-free, fire resistant special compound


In accordance with DIN 4102-12, circuit integrity class E30
On customers request
Available in various configurations
Orange
IP 54

Subject to technical modification.

109

Preventive fire protection

Emergency lighting

Product information
Application

Combined emergency lighting/escape route signage for road tunnels.


pyrofil safety cables with circuit integrity E90 are recommended for power supply.

Technical Data

Housing made of V4A steel, material quality 1.4571


Available in surface or flush-mounting versions
Protection class IP65
Safety glass front cover
Quick-release fasteners
Silicone sealing
Stainless cable inlets, 15 mm diameter
Escape route signage: Light source 2 x 11 Watt TC-L
Emergency lighting: 150 Watt halogen lamp type R7S with asymmetrical reflector

Goods supplied

Combined emergency lighting/escape route signage including fastening devices.

Installation

Surface or flush-mounting

Article No. Type Dimensions PU


(WxHxD) mm

on request

BNL / surface

560 x 400 x 110

1 pc

on request

BNL / flush-mounting

560 x 400 x 110

1 pc

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Safety cables

BNL
Emergency lighting/
escape route signage

Information

Please also take a look at our further tunnel accessories:


Tunnel distribution box and tunnel clamp

110

Subject to technical modification.

Preventive fire protection

E0 multi-cable support

For wall and ceiling installations


in accordance with MLAR 11/2005 3.5.3

Application

Safety cables

Product information
For fire-safe installation of multiple cables or lines along ceilings or walls above fireproof ceilings in
accordance with MLAR 11/2005 (not for functional integrity!).
Excerpt from MLAR 11/2005 3.5.3.:
The special requirements pertaining to fireproof fasteners for lines installed in the area
between floor slabs and suspended ceilings must be observed.
Set consists of multi cable supports E0 and fire protection plugs KDM, 30 mm.

Material

Inner dimensions
Outer dimensions

Sendzimir galvanised steel


E0
approx 80 x 45 x 33 mm
approx 87 x 60 x 33 mm

Cable load

Installation spacing
Cable weight

E0S
approx 55 x 35 x 33 mm
approx 63 x 45 x 33 mm

30 40
6,0 4,5

50 60
3,6 3,0

70
2,6

80 cm
2,3 kg/m

E0 multi-cable support
Article No. Type Inner dimensions (mm) Outer dimensions (mm) PU
3 800 086

E0 multi-cable support

approx 80 x 45 x 33

approx 87 x 60 x 33

25 pcs.

3 800 087

E0 S multi-cable support

approx 55 x 35 x 33

approx 63 x 45 x 33

50 pcs.

Accessories

Distribution boxes

Firestop systems

Technical Data

Support systems

Drill bit and tool set supplied separately.


Recommended drill bit SDS1, recommended tool set SWM-SM 50.

Fixing devices

Goods supplied

Information

To speed up installation times for the E0 multi-cable support, we recommend using the Datwyler SWM-SM 50 setting tool.

Subject to technical modification.

111

Preventive fire protection

Fire protection plugs

Firestop systems

Fixing devices

Support systems

Safety cables

K 6x5
30mm seat depth

KDM
30mm seat depth

Product information
Application

For installation of cable systems with integrated circuit integrity.

Note

The fire protection plugs are suitable for applications in concrete.


In order to guarantee the specified strength of the fire protection plugs, ensure
that the drill holes are at the specified depth.
When using the drill bit supplied with the plug set, the hole depth is maintained.

Article No. Plug Mounting of


1300 953

Plug set K6x5

SAS single clamps,

Contains 200 K6x5 and SDS1 drill bit (required).

30 mm

Single/distance clamps

Recommended tool: set SM 6 SM

with M6 thread

1300 954

Plug set KDM

Single/distance clamps

Contains 200 KDM and SDS1 drill bit (required).

30 mm

with continuous hole 19-63 mm,

Recommended tool set: SWS-SM or SWS-SM 50.

Hermann clamp

1300 954

Plug set KDM

Shaped rails

Contains 200 KDM andSDS1 drill bit (required).

30 mm

2970/2 SLD

Recommended tool set: SWS-SM

(for laying strap clamps)

1300 005

Cable trays, cable ladders,

Plugs KMuF10

M10 thread rod

Distribution boxes

Contains 50 KMuF10.
Required drill bit: SDS Duo-Set hv60

Recommended tool set: SMu10H.

1300 006

Contains 50 KMuF12.

Plugs KMuF12

Cable trays, cable ladders,


M12 threaded rod

301 369

Plugs K6x80

Required drill bit: SDS Duo-Set hv60


Recommended tool set: SMu12H.

Special mounting on insulated

Contains 100 K6x80 for use with standard drill bit.

ceilings or walls with insulation

Min. required depth of 30mm to be guaranteed by the

thickness up to 75mm

depth gauge on the drilling machine.

Recommended tool set: EWA 6x5 SM.

1300 448

Contains 100 K6x110 for use with standard drill bit.

Plugs K6x105

Special mounting on insulated

ceilings or walls with insulation

Min. required depth of 30mm to be guaranteed by the

thickness up to 105mm

depth gauge on the drilling machine.

Recommended tool set: EWA 6x5 SM.

1301 094

Contains 100 KMu LF8

Information

Accessories

Set/Info

112

KMu F10/KMu F12


40mm or 60mm seat depth

Subject to technical modification.

Plugs KMu LF8

tread rod M8

Preventive fire protection

Fire protection plugs


Accessories

1.

2.

3.

SDS Duo-Set
consisting of:
SDS Duo Adapter hv60
3x Duo tapered drill bit 6mm
3. 1x knock-out wedge
1.

SWM-SM
SWS-SM 50

SMu 6 SM

SDS 1 32 mm
SDS 2 42 mm

2.

Safety cables

Product information
The special drill bit enables holes to be drilled to the required depth.

Advantages

Ensures required
- hole depth
- less working time
- less drilling
- longer lasting drill bits

SDS1

Required for plugs K6x5 and KDM

1300 007

SDS 2

Required for plugs KMu LF8

1300 009

SDS Duo-Set hv60

Required for plugs KMuF10 and KMuF12

Article No. Tool set Info


SWM-SM

Recommended for plugs KDM (hammer drill)

1300 013

SMu10H

Recommended for plugs KMuF10

1300 014

SMu12H

Recommended for plugs KMuF12

1300 963

SMu 6 SM

Required for preassembled clamp (hammer drill)

1300 860

SWM-SM 50

Recommended for Hermann clamp (hammer drill)

Information

Accessories

1300 961

Firestop systems

1300 962

Distribution boxes

Article No. Drill bit Info

Fixing devices

Support systems

Application

Subject to technical modification.

113

Preventive fire protection

Fire protection screws


Special plugs

Safety cables

MMS-P 7,5/45
40mm seat depth

MMS-St 6/60
40mm seat depth

Gas concrete plugs


PBD M 6x10

HMS 5/40
30mm seat depth

Identification sign

Product information
Application

For installation of cable systems with integrated circuit integrity.

Note

The mounting screws are suitable for applications in lime-sand bricks and aerated lime-sand bricks,
red bricks and concrete.

Support systems

The gas concrete plugs are suitable for gas concrete P3,3 or better.

Article No. Mounting screws Mounting of Info


SAS single clamps,

Package contains 200 mounting screws

1301 218

HMS 5/40

Simple/distancing clamps

Bore hole outer diameter is 4 mm

with M6 thread


Fixing devices

3800 097

HMS-St 6/60

SAS single clamps,

Package contains 100 mounting screws

Simple/distancing clamps

Bore hole outer diameter is 6 mm

with M6 thread

For assembly, a wrench / nut SW 10


1300 461

MMS-P 7.5/45

Distribution boxes

Firestop systems

Accessories

For assembly, a T-drive adapter 20


is needed

is needed

Shaped rails

Package contains 100 mounting screws

2970/2 SLD

Bore hole outer diameter is 6mm


For assembly, a T-drive adapter 40 is needed

(for laying strap clamps),

Hermann clamps

1300 479

Identification sign

For permanent identification

Set consists of 10 identification

Cable system

of a cable system

signs

in accordance with DIN 4102-12

Article No.

Special plugs Mounting of Info

1301 301

PBD M 6x10

Simple/distancing clamps

Package contains 25 gas concrete plug sets

Shaped rails

Recommended tool set EWP 6x10

Hermann clamps

Cable trays

1301 306

Heavy cable trays

PBD M 10x10

Package contains 25 gas concrete plug sets


Recommended tool set EWP 10x10


1301 313

EWP 6x10

Recommended for plugs PBD M 6x10.

Driven by hammer

1301 302

EWP 6x10 SDS

Recommended for plugs PBD M 6x10.

Driven by hammer drill

Information

Article No. Tool set Info

1301 314

EWP 10x10

Recommended for plugs PBD M 10x10.

Driven by hammer

1301 307

EWP 6x10 SDS

Recommended for plugs PBD M 6x10.

Driven by hammer drill

114

Subject to technical modification.

Preventive fire protection

Plastic armoured conduit


Halogen-free

Plastic armoured conduit, type Kupa DN M

Safety cables

Product information

Support systems

Halogen-free plastic, flame retardant, corrosion resistant


Grey RAL 7035
VDE 0605; DIN EN 50086-1; DIN EN 50086-2-1
3 = Compressive strength medium (750N/5cm)
3 = Impact strength medium (2kg/100m)
4 = min. temperature - 25C
2 = max. temperature + 90C

Halogen-free smooth plastic tube with molded sleeve on one end, in lengths of 3m.
Article No. Tube type Inner [mm] Outer [mm] PU

Fire load kWh/m

1300 600

Kupa DN 16

13,0

16,0

111 m

0,545

1300 601

Kupa DN 20

16,8

20,0

111 m

0,817

1300 602

Kupa DN 25

21,5

25,0

57 m

1,090

1300 603

Kupa DN 32

28,0

32,0

57 m

1,393

1300 604

Kupa DN 40

35,5

40,0

21 m

2,024

1300 605

Kupa DN 50

45,2

50,0

21 m

2,802

1300 606

Kupa DN 63

57,8

63,0

21 m

3,542

In order to attach Kupa plastic armoured conduits, we recommend


SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and
fire protection plugs KDM 30mm.

Please also see our optional installation methods:


Installation of cable bundles in clamps, installation in steel armoured conduits, etc.

Information

Fixing devices

Material
Colour
Approvals
Classification


Firestop systems

Technical Data

Distribution boxes

For laying single and multiple cables on ceilings or walls.


Circuit integrity is achieved for pyrofil-Keram cable types (N)HXH/(N)HXH CL/(N)HXCH
FE180/E30-E60, (N)HXH/(N)HXCH FE 180/E90, JE-H(St)H FE180/E30-E90 and
JE-H(St)HRH FE 180/E30-E90.
Maximum permissible fixing distance: 800mm.

Accessories

Application

Subject to technical modification.

115

Preventive fire protection

Plastic armoured conduit


Halogen-free / Accessories

Bend, type Kupa DN MB

Safety cables

Insertable sleeve, type Kupa DN MM

Product information

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Support systems

Halogen-free plastic insertable sleeve

116

Article No.

Sleeve PU

1300 607

Kupa DN 16

MM

25 pcs.

1300 608

Kupa DN 20

MM

50 pcs.

1300 609

Kupa DN 25

MM

50 pcs.

1300 610

Kupa DN 32

MM

25 pcs.

1300 611

Kupa DN 40

MM

25 pcs.

1300 612

Kupa DN 50

MM

10 pcs.

1300 613

Kupa DN 63

MM

5 pcs.

Halogen-free plastic insertable 90 bend


Article No. Bend PU
1300 614

Kupa DN 16

MB

25 pcs.

1300 615

Kupa DN 20

MB

25 pcs.

1300 616

Kupa DN 25

MB

25 pcs.

1300 617

Kupa DN 32

MB

25 pcs.

1300 618

Kupa DN 40

MB

25 pcs.

1300 619

Kupa DN 50

MB

10 pcs.

1300 620

Kupa DN 63

MB

5 pcs.

Single clamp for plastic armoured conduit


Article No. Clamp type Kupa tube PG / [mm] PU
1300 021

SAS 16

DN 16

1300 023

SAS 20

DN 20

100 pcs.
100 pcs.

1300 026

SAS 26

DN 25

100 pcs.

1300 051

SAS 38

DN 32

25 pcs.

1300 252

SAS 47

D new

DN 40

20 pcs.

1300 234

SAS 55

D new

DN 50

20 pcs.

In order to attach Kupa plastic armoured conduits, we recommend SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm.
Please also see our optional installation methods:
Installation of cable bundles in clamps, installation in steel armoured conduits, etc.

Subject to technical modification.

Preventive fire protection

Steel armoured conduit


Galvanised

Steel armoured conduit, type Stapa DN SV

Safety cables

Product information
Application

For laying single and multiple cables on ceilings or walls.


Circuit integrity E30 is achieved for pyrofil-Keram cable types (N)HXH/(N)HXH CL FE180/E30-E60,
JE-H(St)H FE180/E30-E90 und JE-H(St)HRH FE 180/E30-E90.
Maximum permissible fixing distance: 800mm.

Technical Data

Material
Colour

Approvals
Classification


Support systems

Rolled ingot steel


Hot-dip galvanised, inside and outside,
in accordance with EN/ISO 1461
VDE 0605; DIN EN 50086-1; DIN EN 50086-2-1
4 = Compressive strength heavy (1250N/5cm)
4 = Impact strength heavy (2kg/300m)
5 = min. temperature
- 45C
7 = max. temperature
+ 400C

1300 621

Stapa DN 16 SV

13,3

16,0

30 m

1300 622

Stapa DN 20 SV

17,3

20,0

30 m

1300 623

Stapa DN 25 SV

22,1

25,0

30 m

1300 624

Stapa DN 32 SV

29,0

32,0

21 m

3800 135

Stapa DN 40 SV

37,0

40,0

15 m

1300 626

Stapa DN 50 SV

47,0

50,0

15 m

1300 627

Stapa DN 63 SV

59,5

63,0

15 m

Insertable sleeve, hot-dip galvanised

Firestop systems

Article No. Tube type Inner [mm] Outer [mm] PU

Fixing devices

Steel armoured conduit, round, hot-dip galvanised, in lengths of 3m

25 pcs.

Stapa DN 20 SVM

50 pcs.

1300 641

Stapa DN 25 SVM

50 pcs.

1300 642

Stapa DN 32 SVM

50 pcs.

1300 643

Stapa DN 40 SVM

25 pcs.

1300 644

Stapa DN 50 SVM

10 pcs.

1300 645

Stapa DN 63 SVM

5 pcs.

In order to attach Stapa steel armoured conduits, we recommend


SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm.

Please also see our optional installation methods:


Installation of cable bundles in clamps, installation in plastic armoured conduits, etc.

Subject to technical modification.

Accessories

Stapa DN 16 SVM

1300 640

Information

1300 639

Distribution boxes

Article No. Insertable sleeve PU

117

Preventive fire protection

Steel armoured conduit


Galvanised / Accessories

Safety cables

Galvanised steel armoured conduit


Bend, type Stapa DN SVB
Insertable sleeve, type Stapa DN SVM
End part, type Stapa DN SVE

Product information
Insertable 90 bend, galvanised

Support systems

Article No. Bend PU


1300 648

Stapa DN 16 SVB

15 pcs.

1300 649

Stapa DN 20 SVB

25 pcs.

1300 650

Stapa DN 25 SVB

25 pcs.

1300 651

Stapa DN 32 SVB

20 pcs.
15 pcs.

1300 652

Stapa DN 40 SVB

1300 653

Stapa DN 50 SVB

5 pcs.

1300 654

Stapa DN 63 SVB

3 pcs.

End part, galvanised

Halogen-free end part, full plastic

Information

Accessories

Distribution boxes

Firestop systems

Fixing devices

Article No. End part PU Article No. End part PU

118

1300 684

Stapa DN 16 SVE

25 pcs.

1300 630

Stapa DN 16 SKE

50 pcs.

1300 685

Stapa DN 20 SVE

50 pcs.

1300 631

Stapa DN 20 SKE

100 pcs.

1300 686

Stapa DN 25 SVE

50 pcs.

1300 632

Stapa DN 25 SKE

100 pcs.

1300 687

Stapa DN 32 SVE

50 pcs.

1300 633

Stapa DN 32 SKE

50 pcs.

1300 688

Stapa DN 40 SVE

25 pcs.

1300 634

Stapa DN 40 SKE

50 pcs.

1300 689

Stapa DN 50 SVE

10 pcs.

1300 635

Stapa DN 50 SKE

25 pcs.

1300 690

Stapa DN 63 SVE

5 pcs.

1300 636

Stapa DN 63 SKE

20 pcs.

Single clamp for steel armoured conduit


Article No. Clamp type

Stapa conduit PG / [mm] PU

1300 021

SAS

16

DN 16

1300 023

SAS

20

DN 20

100 pcs.

1300 026

SAS

26

DN 25

100 pcs.

1300 051

SAS

38

DN 32

25 pcs.

1300 252

SAS

47

D new

DN 40

20 pcs.

1300 234

SAS

55

D new

DN 50

20 pcs.

In order to attach Stapa steel armoured tubes, we recommend SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm.
Please also see our optional installation methods:
Installation of cable bundles in clamps, installation in plastic armoured conduits, etc.

Subject to technical modification.

100 pcs.

Preventive fire protection

Steel armoured conduit


Black varnished

Steel armoured conduit, type Stapa DN SL

Safety cables

Product information
Application

For laying single and multiple cables on ceilings or walls. Circuit integrity E30 is achieved for
pyrofil-Keram cable types (N)HXH/(N)HXH CL/ FE180/E30-E60, JE-H(St)H FE180/E30-E90
and JE-H(St)HRH FE 180/E30-E90.
Maximum permissible fixing distance: 800mm.

Technical Data

Material
Colour

Approvals
Classification


Support systems

Rolled ingot steel


Stove-enamel based on alkyd melamin resin,
free of heavy metals, black
VDE 0605; DIN EN 50086-1; DIN EN 50086-2-1
4 = Compressive strength heavy (1250N/5cm)
4 = Impact strength heavy (2kg/300m)
5 = min. emperature
- 45C
6 = max. temperature
+ 250C

Fixing devices

Steel armoured conduit, round, black varnished, in lengths of 3m


1300657

Stapa DN 16 SL 13,3

16,0

30 m

1300658

Stapa DN 20 SL 17,3

20,0

30 m

1300659

Stapa DN 25 SL 22,1

25,0

30 m

1300660

Stapa DN 32 SL 29,0

32,0

21 m

1300661

Stapa DN 40 SL 37,0

40,0

15 m

1300662

Stapa DN 50 SL 47,0

50,0

15 m

1300663

Stapa DN 63 SL 59,9

63,0

15 m

Firestop systems

Article No. Tube type Inner [mm] Outer [mm]

Insertable sleeve, black varnished


25 pcs.

Stapa DN 20 SLM

50 pcs.

1300 668

Stapa DN 25 SLM

50 pcs.

1300 669

Stapa DN 32 SLM

50 pcs.

1300 670

Stapa DN 40 SLM

25 pcs.

1300 671

Stapa DN 50 SLM

10 pcs.

1300 672

Stapa DN 63 SLM

5 pcs.

In order to attach Datwyler Stapa steel armoured conduits, we recommend SAS single clamps
with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and
fire protection plugs KDM 30mm.

Please also see our optional installation methods:


Installation of cable bundles in clamps, installation in plastic armoured conduits, etc.

Subject to technical modification.

Accessories

Stapa DN 16 SLM

1300 667

Information

1300 666

Distribution boxes

Article No. Insertable sleeve PU

119

Preventive fire protection

Steel armoured conduit


Black varnished / Accessories

Safety cables

Steel armoured conduit black varnished


Bend, type Stapa DN SLB
Insertable sleeve, type Stapa DN SLM
End part, type Stapa DN SLE

Product information
Insertable 90 bend, black varnished

Support systems

Article No. Bend PU


1300 675

Stapa DN 16 SLB

15 pcs.

1300 676

Stapa DN 20 SLB

25 pcs.

1300 677

Stapa DN 25 SLB

25 pcs.

1300 678

Stapa DN 32 SLB

20 pcs.
15 pcs.

1300 679

Stapa DN 40 SLB

1300 680

Stapa DN 50 SLB

5 pcs.

1300 681

Stapa DN 63 SLB

3 pcs.

End part, black varnished

Halogen-free end part, full plastic

Firestop systems

Fixing devices

Article No. End part PU Article No. End part PU


1300 693

Stapa DN 16 SLE

25 pcs.

1300 630

Stapa DN 16 SKE

50 pcs.

1300 694

Stapa DN 20 SLE

50 pcs.

1300 631

Stapa DN 20 SKE

100 pcs.

1300 695

Stapa DN 25 SLE

50 pcs.

1300 632

Stapa DN 25 SKE

100 pcs.

1300 696

Stapa DN 32 SLE

50 pcs.

1300 633

Stapa DN 32 SKE

50 pcs.

1300 697

Stapa DN 40 SLE

25 pcs.

1300 634

Stapa DN 40 SKE

50 pcs.

1300 698

Stapa DN 50 SLE

10 pcs.

1300 635

Stapa DN 50 SKE

25 pcs.

1300 699

Stapa DN 63 SLE

5 pcs.

1300 636

Stapa DN 63 SKE

20 pcs.

Single clamp for steel armoured conduit

Information

Accessories

Distribution boxes

Article No. Clamp type

120

Stapa conduit PG / [mm] PU

1300 021

SAS

16

DN 16

1300 023

SAS

20

DN 20

100 pcs.

100 pcs.

1300 026

SAS

26

DN 25

100 pcs.

1300 051

SAS

38

DN 32

25 pcs.

1300 252

SAS

47

D new

DN 40

20 pcs.

1300 234

SAS

55

D new

DN 50

20 pcs.

In order to attach Datwyler Stapa steel armoured tubes, we recommend SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm.
Please also see our optional installation methods:
Installation of cable bundles in clamps, installation in plastic armoured conduits, etc.

Subject to technical modification.

Preventive fire protection

Colour codes in accordance with VDE, CENELEC and SEV standards

Core colours in accordance with DIN VDE 0293 - 308 : 01/2003 (CENELEC HD 308 10/2001)
No. of cores

1(-O)

Function of core

1(-J) 2(-O) 2(-J) 3(-O) 3(-J ) 3a(-O) 4(-O) 4(-J ) 4a(-J) 5(-O) 5(-J)

PE

LN

LPE

3L

LNPE

2LN

3LN

3LPE

2LNPE

4LN

3LNPE

Yellow-green (PE)
Blue (N)
Brown (L)
Black (L)
Grey (L)
Colour code for cables 6 cores
Phase conductor
= Black with white number printing
Protective conductor = Green-yellow

L = Phase conductor
N = Neutral conductor
PE = Protective conductor

(a only for certain applications)

Safety cables

Cable printing
In order to guarantee the retraceability, all pyrofil cables are identified with the production batch.
The meter marking simplyfies the cable handling.
Printing example

DATWYLER PYROFIL KERAM FE180 N x MM2 SWISS MADE PRODUCTION BATCH METER MARKS

Core colours in accordance with VDE 0815 for fire alarm cables JE-H(ST)H...Bd
1. Two pairs
2. Three pairs and more
Pair 1: a-core blue, b-core red Pair 1: a-core blue, b-core red
Pair 2: a-core grey, b-core yellow Pair 2: a-core grey, b-core yellow
Remark: Only two pair cable is a Quad Pair 3: a-core green, b-core brown
Pair 4: a-core white, b-core black
Core a

Core b

1
2
3
4

Support systems

Ring group 1
Ring group 2
Ring group 3
Ring group 4

Each bundle is part of a ring group.


All cores of a bundle are identified by the ring colour
or by a plastic helix with printed numbers. Counting to
be started at inside layer.

Fixing devices

Pair

1 2 3 4 5 6 7 8 9 10

11 12

13 14 15 16

17 18 19 20

4 cores

II

II

8 cores resp.
4 pair

II

III

IV

II

III

IV

II

III

IV

II

III

IV

II

III

IV
Distribution boxes

Ring group
consist. of

Ring colour

Helix
Core colours of wiring cables J-H(ST)H...Bd
Basic colours of insulation of the 5 star quads of a bundle
1. Quad: Basic colour of all cores red
4. Quad:
2. Quad: Basic colour of all cores green
5. Quad:
3. Quad: Basic colour of all cores grey

Basic colour of all cores yellow


Basic colour of all cores white

Accessories

Bundle no.

Firestop systems

Identification of bundles

Circuit 1
Circuit 2

Subject to technical modification.

a-Core
b-Core
a-Core
b-Core

The bundle where counting has to be started


is identified by a red plastic tape.
Remaining bundles are identified by white or
neutral tapes.

Information

The cores of a quad are identified by rings

121

Preventive fire protection

E30-E90 support systems


Preventive fire protection and circuit integrity
The co-ordinated and licensed Datwyler products enable optimal system approaches
and guarantee quality, cost-efficiency, saving of time and security.

300 mm

Standard laying technics with single clamp (of different manufacturers)

Safety cables

600 mm

Standard laying technics with strap clamp with trough (of different manufacturers)

600 / 800 mm
bundling e.g. 30 cables 3x1,5mm2

600 / 800 / 1200 mm


Single clamp: 2,5 kg/m
Strap clamp: 2,5 kg/m
also with cable conduit

Firestop systems

Datwyler E30-E90 Support systems

Fixing devices

Support systems

Hermann clamp:

with thread rod suspension


10Kg

1200 mm

Information

Accessories

Distribution boxes

Standard cable tray (of different manufactures)

122

with/without thread rod suspension

30Kg

1500 mm

Datwyler cable tray without thread rod suspension


for wall and ceiling installation.
Optional laying techniques with different cable tray manufacturers.

Subject to technical modification.

Preventive fire protection

EN European Norm

Support systems
Accessories

Distribution boxes

Firestop systems

EN 50200
EN 50267-1

Information

Method of test for resistance to fire of unprotected small cables for use in emergency circuits
Common test methods for cables under fire conditions. Tests on gases evolved during combustion
of materials from cables. Apparatus
EN 50267-2-1
Common test methods for cables under fire conditions. Tests on gases evolved during combustion
of materials from cables. Procedures. Determination of the amount of halogen acid gas
EN 50267-2-2
Common Test Methods for Cables Under Fire Conditions - Tests on Gases Evolved During Combustion
of Materials From Cables - Part 2-2: Procedures - Determination of Degree of Acidity of Gases for Materials
by Measuring pH and Conductivity
EN 50267-2-3
Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials
from cables. Procedures. Determination of degree of acidity of gases for cables by determination of the weighted
average of pH and conductivity
EN 50362
Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
EN 50363-5
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked
insulating compounds
EN 60228
Conductors of insulated cables
EN 60332-1-1 Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation
for a single insulated wire or cable - Apparatus
EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation
for a single insulated wire or cable - Procedure for 1kW pre-mixed flame
EN 61034-1
Measurement of smoke density of cables burning under defined conditions. Test apparatus
EN 61034-2
Measurement of smoke density of cables burning under defined conditions. Test procedure and requirements

Fixing devices

IEC 60228
Conductors of insulated cables
IEC 60331-1 Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a
temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall
diameter exceeding 20 mm
IEC 60331-11 Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame
temperature of at least 750 C
IEC 60331-2 Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a
temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall
diameter not exceeding 20 mm
IEC 60331-21 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements Cables of rated voltage up to and including 0,6/1,0 kV
IEC 60331-23 Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements Electric data cables
IEC 60331-25 Tests for electric cables under fire conditions - Circuit integrity - Part 25: Procedures and requirements Optical fibre cables
IEC 60332-1-1 Test on electric and optical fibre cables under fire conditions. Part 1-1
Test for vertical flame propagation for a single insulated wire or cable - Apparatus
IEC 60332-1-2 Test on electric and optical fibre cables under fire conditions. Part 1-2
Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
IEC 60332-3-10 Tests on electric cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted
bunched wires or cables - Apparatus
IEC 60332-3-22 Tests on electric and optical fibre cables under fire conditions Part 3-22: Test for vertical flame spread
of vertically-mounted bunched wires or cables Category A
IEC 60332-3-23 Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread
of vertically-mounted bunched wires or cables - Category B
IEC 60332-3-24 Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread
of vertically-mounted bunched wires or cables - Category C
IEC 60332-3-25 Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread
of vertically-mounted bunched wires or cables - Category D
IEC 60754-1 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount
of halogen acid gas
IEC 60754-2 Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of
gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity
IEC 60794-1-2
Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures
IEC 61034-1
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
IEC 61034-2
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure
and requirements

Safety cables

IEC International Electrotechnical Commision

Subject to technical modification.

123

Preventive fire protection

Safety cables

VDE Association for electrical, electronic & information technologies


VDE 0472-814 Testing of cables, wires and flexible cords; continuance of isolation effect under fire conditions
VDE 0482-200
Method of test for resistance to fire of unprotected small cables for use in emergency circuits
VDE 0482-267-1
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of
materials from cables - Part 1: Apparatus
VDE 0482-267-2-1 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of
material from cables - Part 2-1: Procedures; determination of the amount of halogen acid gas; German version EN502672-1:1998
VDE 0482-267-2-2 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of
material from cables - Part 2-2: Procedures; determination of degree of acidity of gases for materials by measuring pH and
conductivity
VDE 0482-267-2-3 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of
material from cables - Part 2-3: Procedures; determination of degree of acidity of gases for cables by determination of the
weighted average of pH and conductivity
VDE 0482-332-1-1 Test on electric and optical fibre cables under fire conditions. Part 1-1
Test for vertical flame propagation for a single insulated wire or cable - Apparatus
VDE 0482-332-1-2 Test on electric and optical fibre cables under fire conditions. Part 1-2
Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
VDE 0482-362
Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
VDE 0482-1034-1 Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
VDE 0482-1034-2 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and
requirements

DIN German Institute for Standardization


DIN 4102-12

Fire behaviour of building materials and building components- Part12: Circuit integrity maintenance of
electric cable systems; requirements and testing

Fixing devices

Support systems

BS British Standard
BS 5839-1+A2

Fire detection and fire alarm systems for buildings. Code of practice for system design, installation,
commissioning and maintenance
BS 6387
Specification for performance requirements for cables required to maintain circuit integrity under fire conditions
BS 7629-1
Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke
and corrosive gases when affected by fire. Multicore and multipair cables
BS 7655-0
Specification for insulating and sheathing materials for cables. General introduction
BS EN 60228
Conductors of insulated cables
BS 8434-2 +A2 Test for unprotected small cable for use in emergency circuits BS EN 50200 with a 930C flame and
with water spray

Firestop systems

VdS Inspected. Approved. Safe.


VdS 3423

E90 Kabel fr Wasser-Lschanlagen mit zustzlichem Funktionserhalt bei Einwirkung von Wasser,
Anforderungen und Prfmethoden (Entwurf )

NBN 713-020

Fire fighting - Fire performance of building materials and products - Fire resistance of building materials

Information

Accessories

Distribution boxes

NBN Belgian Norm

124

Subject to technical modification.

capacity

bu

asset
m a n a ge
m en

urce
reso
m e nt
nag e

technology, ne
tw

,
ing

ork

ild

e
man nerg
age y
me
ma

m a n a ge m e nt

nt

ture
ruc ent
t
s
m
ra
nf age
an

documentation
&
visualisation

planning
&
controlling

analysing
&
managing

documentation of all objects


numeric
graphical
topological

process
workflow generation
budgeting
work orders

troubleshooting
escalation management
resource optimisation

analysis,
reports, queries

active risk
management

remote monitoring
remote controlling

service and
maintenance automisation

Panorama
Management Software Solution
Support of universal building, technology
and network management

Datwyler

125

Panorama
Customised solutions

Optimal planning by
comprehensive function modules
Panorama
a Datwyler solution

Planning by
workflows

functions

Infrastructure
mapping
complete documentation
of all recorded objects

overview from initial


layout to roll-out

infrastructure visualisation
and management

set-up of processes
by ITIL
coordination
of resources

realtime monitoring of all current values

Panorama supports the documentation of all objects to be recorded and the


visualisation of all processes and workflows to manage these objects including
any generation of activities and assignment of tasks around the service and
maintenance management as well as fault and alarm management.

Individual solutions by deploying Panorama functional modules

Sites
graphic and alphanumerical site
management
visualisation of imported CAD, GIS
and Google Earth data
area management information such
as utilisation, energy consumption
and cost data
calculation and evaluation of site data

126

Datwyler

Buildings
technical and commercial building
management
visualisation of imported CAD, GIS
and Google Earth data
facility management information
such as heating systems, cabling
infrastructures, climate and access
control
calculation of lease/additional costs
visualisation of consumption data
maintenance and service management
by processes and workflows

control centre

resources

processes

networks

technologies

buildings

sites
cockpit

Panorama is an universal management


software, optimised for networks,
technologies and buildings. The software
can be deployed in many industries such
as telecommunications, electrical
engineering and finance.

objects

assignment of
activities/tasks

Panorama
Customised solutions

Technologies
facilities and devices visualisation
and documentation
device/array layout, configuration
and operation via remote monitoring
and remote control
reports support fault management, deficiency analysis and asset
management

Resources
coordination of staff, tools, equipment, machinery
planning of maintenance and service
activities
free definition of resources and
intervals
Control centre
control centre function for building
control, transportation and energy
systems, production lines and further
applications
remote monitoring and remote control enable control of heterogeneous
technologies
visualisation and monitoring of technical processes (Supervisory
Control and Data Acquisition, SCADA)

Networks
management and visualisation, from
cable trays up to single optical fibre
illustration of infrastructure including
all logical connections
workflow and task instructions for
patch panel moves, adds, changes

Fault management
and alarm systems
incoming alarms ordered
by priorities
individually defined workflows enable to send emails, to create pop-up
screens and to start assignments of
tasks and processes

Processes, workflows
processes and workflows for layout,
installation and roll-out: support of
maintenance and service intervals,
fault and alarm management, IT
Infrastructure Library (ITIL), et cetera

Development of individual
solutions for technical and
commercial building management
Some examples are:
collection of metering data
connection to facility management system
benchmarking
calculation and billing

Datwyler services

Project approach to implement Panorama


Analysis
needs/requirements
feasibility
concept
user requirement
specifications

User requirement
specifications

Design
technical
specifications
statement
of work
interface
definitions

Statement
of work

Implementation
software
adaptation
interface
adjustment
system check

Acceptance
procedure

Roll-Out
roll-out to user

Datwyler takes responsibility


for all necessary services:
implementation of Panorama software
operation of Panorama software
management of physical infrastructure
based on an SLA

Going live

Optional Datwyler support


economic efficiency calculation
project management, quality management

training, documentation
user support, maintenance, hosting
Datwyler

127

System solutions
from a single source

ICT Networks

Leading know-how
As a provider of total solutions for information and telecommunication networks,
Datwyler possesses extensive know-how accumulated over decades:
- Almost 100 years of experience in cable production.
- Leading material, production and process know-how in the fabrication of copper
and fibre-optic cables and components.
- Solid electro-technical competency.
- Close collaboration with renowned technical universities, international standards
committees, and independent testing institutes.
- Broad systems competence.
Diverse applications
In the field of ICT networks Datwyler concentrates on communication infrastructures
for public and commercial buildings and for FTTx networks.
Some examples are:
-
-
-
-
-
-

Office, industrial and exposition buildings


Data centres
Hotels and hospitals
Stadiums, theatres, concert halls
Airports and train stations
FTTx projects of public utility companies and energy supply companies

In these market segments we can also flexibly meet individual customer requirements
up to and including turnkey and multi-site projects with our cost-effective, modular
system solutions and compehensive services.

128

Datwyler

Complete system solutions


- Screened and unscreened copper system solutions (categories 3 to 7A) for the transmission of voice, data, video, CATV,
control signals and remote power (power over Ethernet,
PoE).
- Innovative fibre-optic system solutions with single-mode and
multimode optical fibres for indoor and outdoor applications,
from LAN backbones to FTTH in-house cabling.
- Software solution for building, technology and network management.
- Extensive services ranging from consulting and planning via
pre-fabrication, logistics and installation to system maintenance.
- Established worldwide, actively managed and certificated
partner network.
- Rigorous training and certification programme to guarantee
optimal installation quality of our systems and solutions.
- 20-year warranty covering the entire system.

Yangshan Deepwater Port administration centre, Shanghai

Selected reference projects


Airrail Center
Party school campus
Kunming Airport
UBI Banca (1964 branch offices)
Swiss parliament building
Dexia BIL

Frankfurt a.M. Crane House South


Hangzhou Dubai Motor City
Kunming Swisscom IT Services
Bergamo UBS central administration, Flurhof
Berne Allianz Arena
Luxembourg KPMG German headquarters

Cologne
Dubai
Zollikofen
Zurich
Munich
Berlin

Focus on customer value


Datwyler stands for more than just the fabrication and distribution of products. For your ICT networks we offer future-proof,
modular, customised one-source solutions for all your specific
applications as a uniquely attractive overall package, with all
the necessary test certificates, authorizations and certificates
and with long-term warranties.
The interaction of these elements creates added value. As a
customer you benefit from maximum network availability and
high investment protection, even with regard to future applications, expansions and changes.

Allianz Arena, Munich

Datwyler

129

Product Overview

Integrated, future-proof cabling solutions for ultimate


reliability in voice, data, video and CATV applications

Patch cords
PS-TERATM/RJ45

More than just products


With the complete packages offered by Datwyler you are
opting for comprehensive application-neutral and provider-independent system solutions encompassing the communication infrastructure for office and industry environments and for
FTTx projects.
For Datwyler quality testing and quality management begin during the cable production process. Here relevant electrical and
mechanical data are recorded online and automatically compared with the predefined specifications. Mostly these specifications considerably exceed current standards and drafts.
Datwyler follows the same procedure for the production of connection components, e.g. data outlets, patch panels and patch
cables for copper and fibre-optic systems.
Marking of individual components ensures that data measured
up to the time of production can be called up at any point in the
future. This gives users or investors a high degree of certainty
that the products used and manufactured provide the durability demanded by them.

Patch panel
MPS 12x, 16x, 24x, 32x
for MS 1/8 or PS-TERATM
modules

Module
Faceplate
for PS-TERATM module PS-TERATM 1/8 Cat.7

Faceplate
for MS-K Plus 1/8
modules

RJ45 module
MS-K Plus 1/8 Cat.6A

Industrial
data outlet IP67
for MS 1/8 module

Industrial
REG adapter MS IP20
for MS 1/8 module

Industrial
patch cord PUR

Copper
patch cord

Data outlets
CSD Plus 2/8 K,
CSD Plus 2/8 U
Cat.6A (IEC)
Patch panel
CSA 24/8 Plus Cat. 6A

130

Datwyler

FO patch panel
OV-A
FO data outlet

FO patch panel

FO wall-mounted
distribution box
OV-W

FO indoor cable

FO in- and outdoor cable


FO Safety outdoor cable

uninet installation/
flexible cable

e.g.:
Cat.6A: 7060 4P
Cat.7: 7080 4P
better than Cat.7A:
7150 4P

Multimedia
TV balun, active balun up to
862 MHz for the distribution of
CATV signals

Multimedia
TV panel, active distributor field up to
862 MHz for the distribution of CATV signals

Datwyler

131

Product Overview

Copper

Fibre optic

Cables

Connection

Cables

Connection

uninet installation/
flexible cable

Modules

optofil indoor cable

Fibre optic adapters and couplers

Copper patch cords

Patch panels

optofil outdoor cable


optofil Safety

Fibre optic patch panels

Multiple cable, highly flexible


pre-assembled copper data cables

Faceplates

Fibre optic patchand adapter cable

Fibre optic faceplates

Multiple cable
pre-assembled copper data cables

Floor-box solutions

Fibre optic multiple cable

Fibre optic wall mounted


distribution boxes

Measurement cable

Accessories

Fibre optic
multiple cable
BreakOut system

Accessories

screened / unscreened

screened / unscreened

Are you looking for a building, technology and network management software which enables effective planning, management, documentation
and control of all objects and processes around your infrastructure? Feel free to ask for details about Panorama!

132

Datwyler

High Density

Wireless

Active

MHD

Network/Server racks

Wi-Fi

Multimedia and
switching

MHD housings

Network rack

Wi-Fi Arrays

TV panel
active distributor field up to 862 MHz
for the distribution of CATV signals

MHD copper distribution cartridges

Server rack

Transformers

TV balun
active balun up to 862 MHz
for the distribution of CATV signals

MHD multiple cable


pre-assembled copper data cables

Wall chassis

Access points

Network cameras

Management system

Video monitoring system

Accessories

Switches

Modular High Density


cabling system

MHD FO distribution cartridges

MHD multiple cable


pre-assembled FO data cables

Minirack

Accessories

Powerful Wireless Fidelity

Find our ICT network products and solutions in the respective catalogue.

www.datwyler.com

Datwyler

133

Maximum flexibility
in installation

Building Automation
The modular product portfolio
for optimised system integration

System ECO-A
flatform cable system

System ECO-B

products for the decentral,


modular integration

System ECO-C

products for the central,


clear integration

System ECO-D

products for the decentralised,


fast integration

System ECO-E

products for simple,


economic integration

Modern office and administration buildings


require future-proof, adaptable electrical systems.
Users are no longer willing to be restricted by
non-flexible solutions. They demand plug-andplay in the form of flexible control and automation of virtually every technical function of the
building. With building automation solutions
from Datwyler, many functions and systems
such as HVAC, lighting, security and load
management can be easily integrated.
Control tasks can be done centrally, decentrally
or automatically.

System ECO-F
products for flexible,
efficient integration

System ECO-M
products for
Smart Metering

System ECO-S
software

System ECO-T

SIP door communication

134

Datwyler

Leading know-how
As a provider of total solutions for the electrical and communications infrastructure of public and commercial buildings, Datwyler possesses leading know-how acquired over
decades. Applying our competence in materials, production
and processing in the fabrication of flatform cables, we have
developed the ECO-A system, a comprehensive solution
combining flexible power distribution with control and automation of all building functions.
Complete system solutions
Decentral, modular and pluggable Datwyler offers sustainable system solutions tailored to changing customer needs,
upcoming technologies and energy-efficient operation.
Thus, our building automation solutions ensure high operational reliability and low operational costs.

Sony Center, Berlin

Selected reference projects


MDR
NBV UGA
Petronas Towers
District hospital

Erfurt Daimler Chrysler


Herongen Frankfurt Stock Exchange
Kuala Lumpur Sony Center
Winterswijk

Diverse applications
In recent years Datwyler has extended its proven ECO-A portfolio to include eight product groups for building automation
based on the KNX standard. These product groups are used
in system solutions for basic infrastructure as well as tenant
improvements, including a wealth of applications such as
responsive lighting, intelligent shading, HVAC, connections
to third party systems, visualisation, power data metering
and door communication via SIP. The product groups have
a modular structure and can be deployed in any combination. This makes it possible to achieve a cost-effective solution
for every project. Combined with our flatform cable systems for power distribution and data transmission and with
our control and visualisation software which makes various
systems available on one platform, the Datwyler product
portfolio meets all requirements of intelligent building
automation.

Stuttgart
Frankfurt
Berlin

Customer value in focus


Datwyler stands for more than the production and distribution of high-quality products. For your technical building systems we provide modular total solutions from one source,
including consulting, support, logistics, warranty and turnkey responsibility if required.
Integrating these elements into sophisticated attractive overall packages creates added value. As a customer you benefit
from:
- drastically reduced cabling
- the use of factory-ready modules
- easier planning and documentation
- reduced installation time
- high flexibility, rapid changeability
and adaptability
- higher safety due to lower fire loads
- cost-saving operation
- lower power consumption
- cost-effectiveness due to customised
total solutions
- long-term investment protection

Datwyler

135

Product Overview

System description
Modern building services installation calls for control and automation of the widest possible range of functions. Whereas
conventional electrical building services installation merely distributes power and could be switched if necessary, the ECO-A
system meets the higher standards demanded of modern building services.
Compared with conventional electrical installation, modern
building management using a Datwyler buildung automation
system features a minimum of cable expenditure, rapid adaptability, and flexible use of space. This guarantees that your investment will retain its value for decades to come.
Our cabling solutions enables the problem-free linking of a very
wide variety of building services functions and facilities that
have been strictly separated to date such as heating, air conditioning, ventilation, lighting, building surveillance, and load
management. Open and closed-loop control operations can be
centralised or decentralised.
The flatform cables and appropriate pre-assembled plug-in and
screw components make insulation stripping unnecessary and
considerably reduce installation time. The installations can be
modified or extended without any major planning effort.
The modular building automation product portfolio enables
optimised system integration. The portfolio ranges from preconfigured plug-and-play solutions for decentralised systems,
to cost-effective semi-centralised room solutions e.g. for
hotels, hospitals and office buildings to total solutions for
centralised building automation systems.

System
ECO-C
products for
the central,
clear integration

System ECO-E
products for simple,
economic integration

Flatform cable Data


with Data Adapter
outgoing circuit without insulation
stripping for inter-connecting the
sensors with flatform data transmission cables
Combi Adapter
5x2.5+2x0.5
combined data and power output
circuit for flatform cables Combi

Flatform cable Power 5x10


flatform power cable 5x10mm2
e.g. for power supplies

136

Datwyler

Power I Adapter
power in- and output
Flatform cable Power I 7x2,5+5x16mm2
for damp location, flatform power cable system for
engine rooms and industrial applications

Flatform cable Combi


combined data and power flatform cable,
e.g. for lighting supply and switching operations

System ECO-D
compact, plug-in KNX actuators with fast
connection technology for error-free assembly in
intermediate floors or suspended ceilings

Flatform cable Patch


pre-assembled patch cables
to connect consumers and to supply
office actuators

System ECO-B
products for the
decentral, modular
integration

KNX IR
Remote Control
ECO-E ZN1IR

Flatform cable Power 5x10


with Power 5x10 Adapter out
power output circuit for flatform cable Power
5x10mm2 e.g. pre-assembled with floor boxes
and output circuit fuse

KNX sensing device


twofold, fourfold

Flatform cable Data data cable

Data-R round data cable

Datwyler

137

Flatform cable systems and accessories (ECO-A)

CablE

In- and Output

Flatform cable Combi

Output

Combi Adapter-S
5x Energy+Bus
PVC
5x2,5 mm2 + 2x1,5 mm2

Art.No.1300 235

FR/LSOH
5x2,5 mm2 + 2x1,5 mm2

Art.No. 1300 236

Art.No.187 028

Art.No.187 034

Combi Adapter
3x Energy+Bus EIB/KNX
Art.No. 1300 282

Combi Adapter-S
5x Energy

Combi Adapter
3x Energy+Bus
Art.No. 1300 282

Combi Adapter-S
Bus

Combi Adapter
3x Energy

Art.No. 1300 237

Flatform cable Data


PVC
2x1,5 mm2

Art.No. 179 669 / 175 475

FR/LSOH
2x1,5 mm2

Art.No.179 679 / 176 900

Art.No. 1300 350

Data Adapter
EIB/KNX
Art.No. 1300 286

Data Adapter
Art.No. 1300 353

Data Adapter Quick


Art.No. 1300 303

Flatform cable Power 5x2,5 mm2


PVC
5x2,5 mm2

Power Adapter-S
5x Energy

Power Adapter
3x Energy

Art.No. 1301 076

Art.No. 1301 075

Art.No. 187 048

Power Adapter
5x Energy

FR/LSOH
5x2,5 mm2

Art.No. 1301 077

Art.No. 187 053

Flatform cable Power 5x10 mm2


PVC
5x10 mm2

Art.No. 187 014

Power 10 Adapter
5x Energy

Power Adapter
5x Energy

Art.No.. 1300 295

Art.No. 1300 302

FR/LSOH
5x2,5 mm2

Art.No. 187 022

Flatform cable Power I 7x2,5 mm2 IP67


PVC
7x2,5 mm2

Art.No. 187 039

FR/LSOH
7x2,5 mm2

Power I cable glands


for Power I Adapter
Power I Adapter
for screw-tightened connection
7x2,5 InOut
Art.No.1301 325

9-16
13-18
11-20,5

Art.No. 1301 318


Art.No. 1301 319
Art.No. 1301 320

Blind-gland Art.No. 1301 322

Art.No. 187 059

Flatform cable Power I 5x16 mm2 IP65


PVC
5x16 mm2

Art.No. 187 045

FR/LSOH
5x16 mm2

Art.No.187 025

138

Datwyler

Power I cable glands


for Power I Adapter
Power I Adapter
for screw-tightened connection
5x16 InOut
Art.No.1301 316

9-16
13-18
11-20,5
20-26

Art.No. 1301 318


Art.No. 1301 319
Art.No. 1301 320
Art.No. 1301 317

Blind-gland Art.No. 1301 322

Fixing device
Combi Adapter EIB/KNX
5x Energy+Bus EIB/KNX
Art.No. 1300 284

Combi Adapter
5x Energy+Bus
Art.No. 1300 351

Accessories

Uni Fix

Tape

Fix

Combi Tool
stripping tool

Art.No. 1300 290

Art.No. 1300 239

Combi Adapter
5x Energy

ending device

Combi End

Art.No. 1300 169

Art.No. 1300 238

Art.No. 1300 240

Art.No. 1300 283

Uni Fix

Art.No. 1300 290 / 182 181

Combi Tool
stripping tool

Data End

Art.No. 1300 287

Art.No. 1300 240

Fix

Art.No. 1300 239

Uni Fix

Tape

Fix

Art.No. 1300 239

Combi Tool
stripping tool

Power Fix

Tape

Art.No. 1300 290 / 182 181

Art.No. 1300 289

Power End

Art.No. 1300 169

Art.No. 1300 875

Art.No. 1300 240

Power 10 End

Art.No. 1300 169

Art.No. 1300 354

Power 10 Tool
cable stripper
Art.No. 1300 306

Power I Adapter
socket 7x2,5
Art.No. 1301 326

Power I Plug IP67


Art.No. 1301 327

Fix

Tape

Fix

Tape

Art.No. 1300 239

Art.No. 1300 169

Power I End 7x2,5

Power I Adapter
7x2,5 InOut
Art.No.1301 325

Power I Adapter
screw-tightened connection
5x16 Out for single and double branch
connection up to 5x6mm2
Art.No.1301 315

Power I Adapter
screw-tightened connection
5x16 InOut

Art.No. 1300 239

Art.No. 1300 169

Power I End 5x16


Art.No. 1301 321

Art.No.1301 316

Datwyler

139

Building Automation
Mounting
and installation

decentralised mounting
project-specific
configuration
modular devices
plug-in connections

System
ECO-B

System
ECO-C

System
ECO-D

Products for the decentral,


modular integration

Products for the central,


clear integration

Products for the decentralised,


fast integration

Project-specific optimised installation box


for mounting in false ceilings or raised floors.
Use of pre-assembled patch cables to connect
consumers and to supply the box.

System devices, IP and DALI devices and


multi-channel KNX sensors and actuators
for centralised and decentralised installation
in electrical distributors and in rooms.

Compact, plug-in KNX actuators


with fast connection technology for
error-free assembly in intermediate floors
or suspended ceilings.

KNX Basic Module combined with


up to 4 Sub-modules e.g.:
4 x 16 A
Switching Actuator
2 x 8-fold
DALI Actuator
2 x 250 VA
Dimmer
2-fold
Blind Actuator
8-fold
Binary Input
4-fold
Semiconductor Switch
16-fold
EnOcean Gateway

decentralised mounting

Switching Actuator 4 x 16 A
Switching Actuator 6 x 16 A
Switching/
2-fold
Dimming Actuator
2-fold
Blind Actuator
1 x Switch
Combi Actuator
+ 2 x Blinds

56-fold
EnOcean Gateway
+ 4 x 16 A

flat size
plug-in connections
directly to the
Combi cable

centralised mounting

KNX Power supply


KNX/USB interface
KNX/IP interface/router
KNX/DALI Gateway
8 to 16-fold
Binary Input
Binary Output 8 to 16-fold
8 to 12-fold
Load Switch
Blind Actuator 4 to 8-fold

for distribution boards

decentralised mounting

KNX push button interface


2-fold/4-fold

flush- or wall-mounting
devices

KNX presence detector


with constant light dimming
KNX touch panel

optional products
and accessories

140

Datwyler

EnOcean Aerial

EnOcean Aerial

System
ECO-E

System
ECO-F

System
ECO-M

System
ECO-T

Products for simple,


economic integration

Products for flexible,


efficient integration

Products for
Smart Metering

Products for
IP door communication

Highly functional, but easy to-integrate


KNX products with innovative features
for central room functions.

High-quality user interfaces with touchsensitive tactile zones and multitouch function.
Standard push buttons sensors and
EnOcean Wireless sensors.

Meters for electrical energy with standardised


communication interface, network coupler
and versatile temperature sensors for different
applications.

SIP Module System and SIP Doorstations


for door communication via IP network.

Door Camera Steel

SIP Door Module ECO


and Maxi
Push Button Modules

SIP Door Station IP54


SIP Door Station IP54 Video

Multi-functional Actuator 6 x 10 A

3-Phase Energy Meter


Direct- and Transformerconnection
Communication Interface e.g.
KNX, M-Bus, Ethernet et al.

Multi-functional Actuator 4 x 16 A

KNX 3-Phase Energy Meter

Universal Dimming Unit 400 VA

KNX Network Interface

KNX Power Supply


Multi-functional Actuator 4 x 10 A

KNX Touch Display

KNX Sentido Interface

KNX Room Temperature Sensor

KNX Push Button Plus

KNX Contact Temperature


Sensor

Analog/Digital Input 4-fold


RS232 Open Interface
Air Conditioner Controller

Frames and Housings


for the Module System

KNX Data Logger


EnOcean RF push button

IR Remote Control

Touch sensitive Sentido


2-fold

Optical reading device

NTC temperature sensor

Touch sensitive Sentido


4-fold

M-Bus reading software

Find our Building Automation products and solutions in the respective catalogue.

LAN Secure Adapter

Datwyler

141

Power and data


for modern elevators

Elevator cable systems

Unnoticed by elevator passengers, elevator cables


from Datwyler do their job around the world every day.
They reliably transfer power and data between the
elevator cabin and the control system. Withstanding
great mechanical stress, they provide faultless
operation round the clock. No wonder Datwyler
elevator cables are installed in the fastest elevators
and the highest buildings in the world.

142

Datwyler

Space in cities is limited. High-rises are being erected


around the globe. Elevators with ever greater performance are providing rapid access to the upper floors
of these tall buildings. And so the requirements for
the materials used are becoming increasingly tougher.
As a leading manufacturer of elevator cable systems, Datwyler knows the needs. Not only must international standards
be met, but knowledge of customers specific needs is essential. Our reliable elevator cable systems are known for smooth
operation that adds significant comfort to the ride.
Leading know-how
Using various test methods, some of which were developed
by Datwyler, we produce elevator cables for service under the
toughest conditions. Our specialists define materials and designs that even under permanent dynamic loading show no
signs of fatigue. We also offer halogen-free materials for special fire safety concepts.

Spinnaker Tower, Portsmouth

Selected reference projects


Shanghai Oriental Pearl Tower
Canary Wharf
Capital Towers
New World Trade Center

Shanghai Post Tower, German Post headquarters


London Torre Major
Dubai Spinnaker Tower
New York

Bonn
Mexiko City
Portsmouth

Diverse applications
Datwyler elevator cable systems meet every requirement for
electrical connections to the elevator cabin. Aside from power
cables, high-quality data cables are being increasingly requested. Integral fibre optic cable can easily handle large volumes
of data. These modern system solutions connect the elevator
cabin to the controls and to the local data network so passengers can enjoy television and video services in the elevator.
System solutions
dynofil is our total system solution (including services) for
electrical installations for elevators.
Customer value in focus
Datwyler has developed innovative system solutions for electrical installations for elevators. Comprehensive harnessing and
logistics services with modern B2B connectivity round off the
service offering of Datwyler.

Datwyler

143

Product Overview

Suspension devices
for dynofil FL, FM, FH,
module concept and
compensation weight

Installation tools
for simple installation
of FL, FM and FH
dynofil cables

Shaft lighting system

Compensation weight

144

Datwyler

Pre-assembled machine
room cabling (MRC)
ready for installation

Flat cables
FL, FM, FH and
module concept
PVC and zero-halogen

Pre-assembled
hoistway cables/
wires (HW)
ready for
connection
Pre-assembled
travelling
cables (TC)
for travelling
heights up to
400m

Find our products for Elevator cable systems in the respective catalogue.

Datwyler

145

locations
Offices and distribution partners

Global market competence

Datwyler sales and production sites


Datwyler distribution partner
Are you searching for a distribution partner in our export markets?
Visit www.datwyler.com for details of our partners
or contact the relevant branches..

146

Datwyler

Switzerland / Southern Europe / Latin America


Daetwyler Switzerland Inc.
Gotthardstrasse 31, CH-6460 Altdorf
T + 41-41-875 12 68, F + 41-41-875 19 86
info.cabling.ch@datwyler.com
Germany / Benelux / North & Eastern Europe
Dtwyler Cables GmbH
Auf der Roos 4-12, DE-65795 Hattersheim
T + 49-61 90-88 80 0, F + 49-61 90-88 80 80
info.cabling.de@datwyler.com
Austria / Hungary
Dtwyler Cables GmbH, Office Austria
Tenschertstrae 8, AT-1230 Wien
T + 43-1-810 16 41 0, F + 43-1-810 16 41 35
info.cabling.at@datwyler.com
Russian Federation
Dtwyler Cables GmbH, RepOffice Moskow
Business Centre Serebryakova, floor 3, office 1
129343 Moskva, Proezd Serebryakova 6
T / F +7-495-6462615
info.cabling.ru@datwyler.com
Great Britain
Datwyler (UK) Ltd
Unit B, Omega Enterprise Park, Electron Way
Chandlers Ford, GB-Hampshire SO53 4SE
T + 44-2380-279 999, F + 44-2380-279 998
info.cabling.uk@datwyler.com
Asia / Oceania
Datwyler (Thelma) Cables+Systems Pte Ltd
29 Tech Park Crescent, Kang Qiao Industrial Zone, Pudong
SG-638103 Singapore
T + 65-6863 1166, F + 65-6897 8885
sales@datwyler.com.sg
Datwyler (Shanghai) Cables+Systems Co. Ltd
Building 16, No. 1-111, Kang Qiao Dong Road
CN-201319 Shanghai, P. R. China
T + 86-21-6813 0066, F + 86-21-6813 0298
info@datwyler-china.com
Middle East
Datwyler Middle East
RA08BB02 Jebel Ali Free Zone
P.O. Box 263480, VAE-Dubai
T + 971-4 887 0515, F + 971-4 887 0516
info.cabling.mea@datwyler.com

Datwyler

147

Switzerland

Germany

Russian Federation

Daetwyler Switzerland Inc.


Gotthardstrasse 31
CH-6460 Altdorf
T + 41-41-875 12 68
F + 41-41-875 19 86
info.cabling.ch@datwyler.com
www.datwyler.com

Dtwyler Cables GmbH


Auf der Roos 4-12
DE-65795 Hattersheim
T + 49-6190-88 80 0
F + 49-6190-88 80 80
info.cabling.de@datwyler.com
www.datwyler.com

Dtwyler Cables GmbH


RepOffice Moskow
Business Centre Serebryakova, floor 3, office 1
129343 Moskva
Proezd Serebryakova 6
T/F + 7-495-6462615
info.cabling.ru@datwyler.com
www.datwyler.com

Great Britain
Datwyler (UK) Ltd
Unit B
Omega Enterprise Park
Electron Way
Chandlers Ford
GB-Hampshire SO53 4SE
T + 44-2380-279 999
F + 44-2380-279 998
info.cabling.uk@datwyler.com
www.datwyler.com

Dtwyler Cables GmbH


Lilienthalstrae 17
DE-85399 Hallbergmoos
T + 49-811-99 86 33 0
F + 49-811-99 86 33 30
info.cabling.de@datwyler.com
www.datwyler.com
Austria
Dtwyler Cables GmbH
Office Austria
Tenschertstrae 8
AT-1230 Wien
T + 43-1-810 16 41 0
F + 43-1-810 16 41 35
info.cabling.at@datwyler.com
www.datwyler.com

United Arab Emirates


Datwyler Middle East
Unit of Daetwyler Switzerland Inc.
RA08BB02 Jebel Ali Free Zone
P.O. Box 263480
UAE-Dubai
T + 971-4 887 0515
F + 971-4 887 0516
info.cabling.mea@datwyler.com
www.datwyler.com
China
Datwyler Cables+Systems
(Shanghai) Co. Ltd
Building 16, No. 1-111,
Kang Qiao Dong Road
Kang Qiao Industrial Zone, Pudong
CN-201319 Shanghai, P. R. China
T + 86-21-6813 0066
F + 86-21-6813 0298
info@datwyler-china.com
www.datwyler-china.com
Datwyler (Suzhou)
Cabling Systems Co. Ltd
Block 31, 15# Dong Fu Road
Suzhou Singapore Industrial Park
CN-215123 Suzhou, P. R. China
T + 86-512-6265 3600
F + 86-512-6265 3650
sales.harnessing@datwyler-china.com
www.datwyler-china.com

2011 Datwyler -Safety-Katalog - e - 09/2011

Singapore
Datwyler (Thelma)
Cables+Systems Pte Ltd
29 Tech Park Crescent
SG-638103 Singapore
T + 65-6863 1166
F + 65-6897 8885
sales@datwyler.com.sg
www.datwyler.com

Subject to technical modification.

Вам также может понравиться