Вы находитесь на странице: 1из 95

Continue >

Planning, Installing &


Caring For Your

Plunger Pump

Continue

Plunger Pump Tips

Tips On

TIPS

s the title implies, this section is designed to assist you in


planning, installing, and caring for your NATIONAL OILWELL

Plunger Pumps. The following pages contain helpful suggestions


and illustrations on ten of the most important phases of the installation and operation of a plunger pump. Each is presented in
logical order. Also, tip number 11 has a detailed checklist of
application considerations.
Of course, this section could not possibly answer every question
regarding NATIONAL OILWELL Plunger Pumps. However, specific
information is readily available simply by contacting your
NATIONAL OILWELL representative or distributor.

Yours for profitable pumping


Continue >

THIS SECTION CONTAINS TIPS ON:


NO.1 Selecting the right plunger pump . . . . . . . . . . . . . . . . . . . . . . . .1
NO.2 Planning your plunger pump installation . . . . . . . . . . . . . . . . . . .2
NO.3 The importance of a firm foundation . . . . . . . . . . . . . . . . . . . . .3
NO.4 Setting your pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
NO.5 Keeping your head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
NO.6 Getting the most from suction lines . . . . . . . . . . . . . . . . . . . . . .6
NO.7 Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
NO.8 The importance of bypass and relief valves . . . . . . . . . . . . . . . .8
NO.9 Guaranteeing a smooth start-up . . . . . . . . . . . . . . . . . . . . . . . .9
NO.10 Keeping your plunger pump going . . . . . . . . . . . . . . . . . . . . . .10
NO.11 Typical Plunger Pump Inquiry Information . . . . . . . . . . . . . . . .11

Continue >

Plunger Pump Tips

NO. 1

Selecting the right


plunger pump
While weeds are still waving over
the location for your installation, you
should start the job of pump selection.
The size of the pump you select pretty
much depends on the size of the job
it must do.
Fluids to be pumped is one of the
first considerations. Is it corrosive?
What kind of elements or minerals
does it contain? How viscous? What
temperature? Will it be mixed with
other fluid or chemically treated?
What about volume and pressure? What pumping service must
be met by a continuous duty pump?
Low pressure-high volume? Medium
pressure-medium volume? High
pressure-low volume?
Knowing the right answers to the
above questions will help you decide
which size pump to choose. Or what
combination of pumps and pump sizes
offers the most efficient operation for
your particular requirements and
conditions.

To summarize: First, determine


your pumping conditions. Next,
decide on volume and pressure
requirements. Then, select the
pump or pumps which will provide
the best performance without wasting horsepower. Finally, equip your
pumps to tackle your particular
operating conditions. A checklist
of application considerations can
be found on the inside back cover.
NOTES:

______________________

______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
Continue >

w w w. n a t o i l . c o m

NO. 2

Plunger Pump Tips

Planning your
plunger pump
installation
Some pump installations look like
plumbers nightmares simply because
operators preferred to do their
planning as they installed equipment.
At times this may seem like the easy
way, but in practice it often proves to
be the hardest. A few hours spent in
planning can save days even weeks
of installation time while assuring
top performance.
Naturally, the more you plan, the less
likely youll go astray. But you dont
have to be a registered plumber. All
thats needed is a pencil, some paper,
a rule, plus one more important tool:
Good, common sense!
Oddly enough, some of the more
basic things are most often overlooked. Here are a few of the
most common:
1. Dont get fancy. Generally, the
simpler the installation the better
it works.

5. Make sure piping and valves are


the right size and are made for
each other.
6. Make certain connections to tanks
are of the appropriate type and in
line with pump piping.
7. Consider suction and discharge
dampeners as a part of your
original plan.
NOTES:

______________________

______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________

2. Plan for proper drainage of the site.

______________________________

3. Put your pumps as close to tankage


as possible.

______________________________

4. For best suction and discharge


conditions, keep piping straight and
short. If possible, avoid right
angles.

______________________________

______________________________
______________________________
Continue >
w w w. n a t o i l . c o m

Plunger Pump Tips

NO. 3

Anchor bolts are really part of the


foundation, but because they must
match equipment holes, they deserve
special consideration. One way to
assure proper bolt location is to place
them securely in position before
pouring the foundation.

The importance of
a firm foundation
Dont skimp on the foundation. If it
isnt up to the job, youll pay much
more later. A poor foundation is almost
impossible to correct once an installation is completed.
The most important thing is for the
foundation to be adequate. This
means it should have generous topside dimensions and sufficient depth.
Of these, lack of depth is the most
common failing. As a rule of thumb,
4 feet is a good minimum depth.
However, soil conditions in your area
will dictate the depth and foundation
for your installation. Experienced local
contractors can be very helpful.
Where soil is particularly soft, for
example, pilings may be the answer.
Another approach may be to spread
out the bearing area by making the
foundation wider and longer, but less
thick. Where soil isnt soft, but not as
stable as youd like, you may elect to
add support by undercutting at the
base of the foundation as shown in
the sketch below.

Despite careful positioning, however,


it may be almost impossible to adjust
anchor bolts even a fraction of an inch
once bolts are firmly cemented in. You
wont have this problem if you set
each bolt in a grout tube before pouring the foundation. Thus, they are held
in position, yet can easily be adjusted
to align with the drilled holes. Then,
when equipment is grouted in, grout
will fill the tubes to anchor bolts firmly.
There are contractors in most areas
experienced at installing equipment
foundations. It can pay to call on one.
Looking back: A quality foundation
gets things off on the right foot
dont skimp here. Design your foundation to suit soil conditions. Set
anchor bolts in grout tubes before
pouring its an easy way to correct for positioning adjustments.
Finally, consult an experienced
contractor.
NOTES:

______________________

______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
Continue >

w w w. n a t o i l . c o m

NO. 4

Plunger Pump Tips

Setting your pump


A good job of grouting in your pump
is so important that it will pay to have
it done by an expert. Quality of the
grout used is very important, too.
In general, the quality of grout required pretty much depends on massiveness of the equipment to be set.
The bigger the pump, the better the
grout must be. For lighter pumps, a
sand-cement mixture might do.
Heavier pumps may call for metalfilled or epoxy-sand grouts. As a rule
of thumb, grout should be a minimum
of about one inch thick.
Alignment of the pump with directconnected engines, electric motors,
and gear reducers must be maintained during grouting. In fact, its a
good idea to check alignment before
and after grouting because tightening down equipment may change
alignment. Dont overlook alignment
of sheaves and belts for long troublefree operation.
Once the pump is grouted in and
properly aligned, be sure to check
your pump service manual. It will
remind you of proper procedures to
follow before start-up such as
checking oil, tightening bolts and nuts,
etc.
4

Dont forget: The installation and


quality of the grout is most important. The bigger the pump, the better the grout needed. Dont forget
alignment check it before and
after grouting. Always consult
your pump service manual prior
to start up.
NOTES:

______________________

______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
Continue >
w w w. n a t o i l . c o m

Plunger Pump Tips

NO. 5

4. Vapor pressure: Be sure to consider vapor pressure of the fluid you


are pumping. Up to 120 o F, theres
no problem with water, but above
this, you must have additional head
to prevent flash-off of water vapor.
Check vapor pressure requirements
for fluids other than water.
Height of head

Keeping your head


Proper plunger pump operation
depends on suction head. To assure
this pressure, design of the suction
system is probably the most important
thing. However, there are a few other
factors you must consider to ensure
the pump has fluid under proper
pressure and flow conditions to properly fill the plunger area during the
suction stroke.
1. Pipe friction: This is something
you can forget if you use pipe large
enough to give you a maximum
velocity of 2 to 3 feet/second in the
suction line during normal operation.
2. Valve and spring load:
Design of valves helps maintain
pressure. For example, National
Oilwell Plunger Pumps have large
area, heavy spring valves with
flow-thru pressure less than 1 psi.
3. Acceleration head: This is
pressure needed to keep fluid
moving in the suction system in
time with the cyclic motion caused
by plunger strokes. However, a
properly designed suction dampener eliminates the need for acceleration head.

At maximum speed and with maximum sized plungers, a plunger pump


will run properly with a minimum of
8 feet of head providing the factors
previously mentioned are okay. But,
its important to note that even heads
of more than 8 feet dont necessarily
eliminate need for suction dampeners.
At slow speeds or with smaller
plungers, required head is less than
8 feet. In fact, its possible to operate
pumps with good success, but only at
less than maximum speeds.
Lets recap important points:
Use adequate suction lines.
Eliminate harmful surging with
properly designed suction dampeners. Make sure fluid vapor pressure
is matched by additional head. And
be sure the suction chamber has
net positive head during normal
operation.
NOTES:

______________________

______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
Continue >

w w w. n a t o i l . c o m

NO. 6

Plunger Pump Tips


To provide excellent flow characteristics and isolate mechanical vibration,
use the properly sized length of hose
for the pump suction connection. The
table outlines the recommended diameter suction line or header to use with
one or more plunger pumps.

Getting the most


from suction lines

It is also vitally important that fullopening valves be used. All restrictions in the suction system should
be eliminated.

One of your most important considerations in installing suction lines is to


keep them as short and straight
as possible. If turns are required,
45o bends are recommended to maintain constant, efficient flow. If at all
possible, avoid right angles. The
comparison sketches below illustrate
this point.

Pressure surges in suction lines result


from the normal operation of plunger
pumps. Neither the piping design nor
suction pressure can prevent their
occurrence. For this reason, it is wise
to include a suction dampener on
every plunger pump. A dampener will
eliminate these pressure surges the
result being higher operating efficiency
and less change of valve trouble.

As illustrated, its recommended that


the suction line be connected to only
one side of the pump; double lines are
usually necessary. It is advisable that
an eccentric swage or reducer be
installed at the pump connection.
Flow rates in any suction line
should not exceed 2 feet/second.
This can be accomplished in all
plunger pumps by using a suction
line that is one size larger than
the pump suction connection.
Suction
Line
Connection Size
Size
Single
Pump

Two
Pumps

Three
Pumps

Header
Size
Four
Pumps

Looking back: The trick of efficient


suction lines is keep em short and
straight. Right angle turns can be
wasteful and harmful, avoid them if
possible. Watch your flow rates,
3 feet/second is maximum. A properly sized hose on the pump suction connection reduces harmful
vibrations, increases efficiency.
Install suction dampeners on
plunger pumps, theyre one of
your best pump preservers.
NOTES:

Five
Pumps

Six
Pumps

______________________

______________________________
______________________________

2-1/2"

3"

4"

5"

6"

7"

8"

3"

4"

6"

7"

8"

10"

10"

4"

6"

8"

10"

12"

14"

16"

______________________________

5"

6"

8"

10"

12"

14"

16"

______________________________

6"

8"

12"

14"

16"

18"

20"

8"

10"

14"

18"

20"

______________________________

______________________________
Continue >

w w w. n a t o i l . c o m

Plunger Pump Tips

NO. 7

2. Where bends in the line are necessary, they should be as generous


as possible. Most desirable are 45
bends or long-radius formed pipe
bends. Dont bull-head a
discharge line with a tee!
3. Its a good idea to install a discharge desurger when maximum
performance is required.

Discharge!
Honorable discharge is also important for an efficient plunger pump
installation. We have previously
discussed the desirability of proper
suction line design. Next in importance is proper design of the discharge system.
Pressure surges are common to all
plunger pumps in operation. Recognized as vibration in the discharge
line, they give a continual buffeting
to pumps and piping. You cant end
surging, but effects of surges can be
greatly minimized through intelligent
discharge system design. At the same
time, proper design provides fluid
efficiency that gives you the best performance for your installation dollars.

4. The discharge line should be tied


down to a sturdy support as soon
as possible after leaving the pump.
This limits mechanical vibration of
the discharge line and guards
against premature failure.
5. Shut-off valves in the discharge
line should be full-opening. If a
check valve is used, be sure to
install it as far from the pump as
possible to prevent feed back of
pressure surges.
Points to remember: Discharge
lines, like suction lines, will vibrate
pumps and piping its unavoidable. However, a good design with
few sharp turns and sturdy tiedown
will keep discharge lines efficient
and operative.
NOTES:

______________________

Here are some points to check in


your design:

______________________________

1. The discharge line should be as


straight as possible, and not
reduced in diameter until it has
been run a minimum of 20 feet
from the pump.

______________________________

______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
Continue >

w w w. n a t o i l . c o m

NO. 8

Plunger Pump Tips


Pressure relief valve
A properly installed and sized pressure relief valve protects more than
the pump and system. It protects
you and your operators from
possible injury.

The importance
of bypass and
relief valves
Bypass and relief valves for your
plunger pump installation are as
important as insurance for your car.
You shouldnt start the engine without
them. Each type of valve provides
special safeguards.
Bypass valve
You need the following benefits of a
bypass valve on any plunger pump
regardless of size, pressure or volume
requirements:

For proper protection, the relief valve


should be set or adjusted to relieve
whenever the pressure reaches at
least 20% more than the pressure
rating of the plungers being used. Its
size should be sufficient to relieve
complete pump capacity when set for
normal operation. The bypass and
relief valves can be installed on a
common return line to the supply tank.
This saves on piping costs. This line
should be pipe to the top of the supply
tank where a visual check will reveal
if either valve is leaking.

2. Permits oil to circulate to vital working parts before they are loaded.

Touching on the highlights:


Bypass and relief valves are essentials dont pump a stroke without
them. Adjust relief valves according
to pressure ratings of plungers
and make sure they're capable of
relieving maximum pumping capacity. Once again, when in doubt, ask
us for help.

3. Reduces electric motor starting


torque.

NOTES:

1. Protects valves from cavitation by


allowing air to be purged from the
fluid end under low pressure.

______________________

4. Lessens load on the engine clutch


when the pump is started.

______________________________

5. Eliminates danger of over-pressuring the system on start-up.

______________________________

Piping from the bypass valve


should return to the supply
tank, not be connected to the
pump suction.

______________________________
______________________________
______________________________
______________________________
______________________________
______________________________
Continue >

w w w. n a t o i l . c o m

Plunger Pump Tips

NO. 9

5. Check suction and discharge piping


to be sure it is of correct design and
has been cleared of all abrasive
material that might damage the new
pump valves.

Guaranteeing a
smooth startup
Your National Oilwell plunger pumps
are built to keep pumping efficiently
day after day, month after month, year
after year. With this kind of performance ahead, you can afford to take a
few minutes to be sure everything is
A-OK before start-up. Here is a good
check list for a smooth start:
1. Review your operating instructions.
These are provided by National
Oilwell with every pump. They cover
all important features of operation,
components, and maintenance.
2. Double-check weight and grade of
lubricant in the power end to make
sure it matches specifications on
the equipment name tag. Also, consider the temperature of the fluid
being pumped as well as the air
temperature of the installation.

6. Be sure that the lubricator is filled


with the proper oil, that air is purged
from the lubrication lines, and that
the setting is correct to provide the
desired amount of lubrication.
7. Assure normal pump operation by
running pump at bypass pressure
until oil has warmed.
8. Pressure test the entire system,
including relief valve. In getting test
pressures, which may exceed pump
rating, operate the pump at a slower
speed.
9. Check safety switches for operation
under normal conditions of pressure
and pump speed.
By taking a few minutes to make
these and other important checks,
you help assure smooth start-up,
proper continuing operation, and
minimum repair.
NOTES:

______________________

______________________________
______________________________

3. Look over alignment of pump


and prime mover to assure it is
correct and within recommended
guidelines.

______________________________

4. Test hold-down bolts and nuts


as well as bolts and nuts on the
equipment to be certain they are
securely tightened.

______________________________

______________________________
______________________________
______________________________
______________________________
______________________________
Continue >

w w w. n a t o i l . c o m

NO. 10

Plunger Pump Tips

Keeping your
plunger pump going
Once your plunger pump is installed
and running, good housekeeping
does most to assure top performance
at least cost.
A properly maintained installation is
generally a clean one. But what good
housekeeping really means is planned,
day-to-day maintenance. Not a hit-ormiss program, but scheduled maintenance designed to catch trouble
before it develops or while it's small.
This preventive maintenance keeps
little problems little minor repairs
minor.
Some maintenance is basic. For
example, correct lubricant properly
applied to plungers and packing can
mean the difference between success
and failure.
Other maintenance requires careful
attention to operation. Materials for
plungers, packing and valves, for
example, must be compatible with
fluid being pumped. This might simply
require making sure that parts are
replaced by parts of identical material.
But it might also call for material
changes to match changes in fluid or
to correct for ingredients in the fluid
not originally recognized.

NATIONAL OILWELL Pump


Service Manual
NATIONAL OILWELL plunger pumps
are built to provide minimum maintenance. You don't have to baby them,
but like any precision-made piece of
machinery, they require proper care.
This is why a detailed guide to maintenance and trouble-shooting is included
in the service manual provided with
each NATIONAL OILWELL pump.
Reviewing maintenance: Keep
abreast of maintenance, troubleshoot your pumps, and don't be
afraid to get your hands dirty
clean installations lead to extended
service. Visually check plungers,
valves, and packing make sure
they're delivering all the performance they can. And make certain
they're the right ones for the job.
NOTES:

______________________

______________________________
______________________________
______________________________
______________________________
______________________________
Continue >

10

w w w. n a t o i l . c o m

NO. 11

Plunger Pump Tips

Typical Plunger Pump Inquiry Information


TYPE OF SERVICE:
Waterflood

PUMP MOUNTING (cont.):

Water Disposal
Power Oil
Fresh Water
Salt Water
Oil
Other

PRIME MOVER:
Internal Combustion:

CLASS OF SERVICE:
24 Hr/Day
Intermittent
Other

FLUID CHARACTERISTICS:
Corrosive
Non Corrosive
Hydrogen Sulfide
Temperature
Specific Gravity

Fahrenheit

DISCHARGE CONDITIONS:
Psig

Bbl/Day/Gallon Per Minute (GPM)


Bypass Valve
Pulsation Dampener
Shut Off Valve

Feet

(Should be approximately twice discharge volume)

Size Suction Line


Suction Dampener

PUMP MOUNTING:
Outdoors

Indoors
Concrete
Skid
Direct Drive
Gear Reducer
Coupling

w w w. n a t o i l . c o m

Torque

Plungers:

Psig
or Tank Level Head
Ft. Max
Ft. Min
Charge Pump
Capacity of Charge Pump
Length-Suction Line

Fuel
Make & Type
HP
Speed RPM
Clutch
Radiator
Heat Exchanger
Electric:
Voltage
Cycles
HP
Speed
RPM
Frame Size
Nema B, C, D

ACCESSORY ITEMS:

SUCTION CONDITIONS:

Belt Drive
Pump Sheave
Prime Mover Sheave
Belt Length

Inches

Ceramic
Tungsten Carbide (standard grade)
Tungsten Carbide (premium grade)
Other
Packing:
Standard
Other
Packing Lubricator
Valve Style
Valve Service Kit
Chamber Cover
Control Panel Pump
Oil Level Switch
Relief Valve
Hi-Lo Pressure Switch
Hi-Lo Suction Switch
Hi-Lo Tank Switch
Other

Next Section >

11

Technical Data

Continue

Plunger Pump Technical Data

Plunger Pump

Plunger Pump Technical Data

Factors And Formulas


To Pick The Right Pump
It is easy to select the right multiplex pump
to best meet your anticipated volume and
pressure requirements.
1) First calculate the hydraulic horsepower
2) Then determine the input horsepower
required. Use input horsepower to identify
the smallest pump suitable for the
application or the combination of pumps
needed to meet the total volume
requirement.
3) Select the plunger size closest to the
maximum operating discharge pressure
requirement.
4) Determine the operating speed that will
tailor the pump to your volume and
discharge pressure requirements.

Helpful Sizing Formulas:


Horsepower
hyd. hp = gpm X psi X .00058
hyd. hp = bbl/day X psi X .000017
hyd. hp =

gpm X psi
1714

bbl/day X psi
hyd. hp =
58,800
input hp =

hyd. hp
.90 (mechanical efficiency of pump)

Volume
bbl/day

= gpm X 34.285

bbl/day

= m3/d X 6.2897

gpm
gpm
liter

bbl/day
34,285

= bbl/day X .02916
= gallons X 3.785

Pressure
feet water

= psi X 2.31

psi

= feet water X .433

psi

= kg/cm2 X 14.223

m3/d
kg/cm2
mm
kg

bbl/day
6.2897

= psi X .0703
= inches X 25.4

Application
Plunger Pumps
The simplest plunger pump installation is
in reality a complex hydraulic system.
While it is not possible to anticipate all of the
operational peculiarities of a pump installation,
it is to the operators advantage to consider
certain well known design factors and
incorporate these factors into the station
arrangement. The following will help
determine these factors.

Pump And System


Design Factors
Suction pressure
Plunger pumps have certain characteristics
that must be considered in designing the
pump suction piping system to assure
satisfactory performance. While running, a
Net Positive Suction Pressure is required by
a plunger pump to enable it to fill on each
stroke. This pressure is referred to as Net
Positive Suction Head Required (NPSHR) and
is measured on the absolute pressure scale.
The minimum NPSHR of any pump is the
specific suction pressure which will allow the
pump to operate hydraulically with acceptable
performance and volumetric efficiency.
NPSHR is affected by many factors including
but not limited to pump speed, plunger
diameter, valve type and flow through area,
valve spring load, liquid temperature, vapor
pressure of liquid being pumped and most
important in an open suction system local
uncorrected barometric pressure.
A conservative approach to designing a
pump suction system is to assume that while
running any plunger pump requires a
minimum NPSHA (Net Positive Suction Head
Available) of 18 psia, above vapor pressure.
Obviously any NPSHA above this minimum
will result in improved fluid end performance
and provides insurance against unpredictable
changes in operating conditions such as an
increase in liquid temperature, lower supply
tank level, entrained gas, etc

= pounds X .45359

Continue >
w w w. n a t o i l . c o m

Plunger Pump Technical Data


Major positive and
negative pressures in
a pump inlet system:
Positive:
A. Liquid Level above Pump Inlet (psi)
= (feet X .433).
B. Atmospheric Pressure (psia)
= Local uncorrected barometric reading
(inches of mercury X .4912).
C. Gas Blanket Pressure (psi) (usually of small
magnitude and can be ignored in NPSHA
calculations).
Negative
A. Vapor Pressure of Fluid (psia)
B. Friction in Piping (psi)
C. Acceleration Head (psi)

Supply Tank Elevation


The supply tank should be located at an
elevation as high as possible in relation to the
pump suction, taking advantage of the natural
terrain. Since pipe friction is usually of a low
order, it is sometimes advantageous to disregard the accepted rule to make the suction
line as short as possible and increase line
length in order to gain additional tank
elevation.
Before locating the pump and supply tank,
make calculations to determine if an elevated
tank with a long inlet line or a tank at a lower
elevation with a short inlet line provides the
greater NPSHA.

Atmospheric Pressure
This is the true local uncorrected barometric
pressure at the altitude of pump location
expressed in psia. Note: Barometric pressure
as reported by the weather bureau is normally
corrected to sea level conditions. The
uncorrected reading must be used.

Gas Blanket Pressure


A gas blanket on the supply tank adds
additional positive pressure to the suction
system. Furthermore, a gas blanket of a few
ounces prevents absorption of oxygen and
reduces corrosion in the pumps and piping.

Vapor Pressure
Vapor pressure is the absolute pressure at
which the liquid will change to vapor at a given
temperature. Vapor pressure becomes most
critical when pumping liquid hydrocarbons;
e.g., propane, crude oil, butane, L.N.G., etc.,
or water at elevated temperatures.

Friction in Piping
The suction line should be as short as
practical with a minimum of bends and fittings.
A single inlet line between pump and tank or
header should be adequate for most
installations. When more than one pump is
drawing from the same tank, it is best to run
individual suction lines from each pump to the
tank. If bends or elbows are necessary in the
line, they should be of long radius design.

Acceleration Pressure
(Head)
Acceleration pressure (head) is the theoretical
inertia effect of the fluid mass in the suction
line. In effect, it is the head necessary to
accelerate the fluid at the beginning of each
plunger stroke and is a function of the volume
of fluid in the suction line, the pump speed,
number of plungers, and pump displacement.
Acceleration pressure (head) is probably the
least understood of all the factors which can
affect pump performance. In some cases,
acceleration pressure (head) can be quite
large in reciprocating pumps having long
suction lines and operating at high speed.
The NPSH required to accelerate cold
water without cavitation may be calculated
with the formula:
Pac

KNLQ
Ds2

Where:
Pac

= Acceleration pressure(psia)

Continue >
2

w w w. n a t o i l . c o m

Plunger Pump Technical Data


Factor for type of pump:
Duplex Double Acting Pump
K = .000451
Triplex Single Acting Pump
K = .000259
Quintuplex Single Acting Pump
K = .000157
N = Pump Speed (rpm)

Typical Inlet System


(Open Type)
Net Positive Suction Head Required
NPSHR (Net Positive Suction Head Required)
= The absolute pressure in psia, above vapor
pressure, as determined by test, required to
fill the pump cylinders sufficiently. (18.0 psia
assumed in these examples).

L = Inlet Line Length (Ft.)


Q = Pumped Volume (gpm)
Ds

= Inlet Line Diameter (inches)

Acceleration Pressure
Calculation
Example calculation of Acceleration pressure
(head). Assume a pump installation with
the following as given.

Net Positive Suction Head Available


NPSHA (Net Positive Suction Head Available)
= That pressure in psia of liquid being
pumped existing at the pump inlet.
Pa

= Atmospheric pressure in psia in


relation to altitude.

Pv

= Vapor pressure in psia of liquid


being pumped.

Pf

= Pressure drop in psi caused by


friction in piping and fittings.

Triplex Single Acting Pump = .000259


Pump Speed = 300 rpm
Inlet Line length = 20 ft.
Inlet Line Diameter = 6"
Pumped Volume = 138 gpm

Calculate the Acceleration head.


KNLQ
Ds2

Pac

Pac

(.000259)(300)(20)
=
36

Pac

Pac

= .043 psia or (1ft. of head)

1.554
36

By varying the pipe diameter in the above


calculation it will be readily seen that large
diameter suction pipe is important. In order to
determine total NPSHA (Net Positive Suction
Head Available) the calculated acceleration
pressure result should be subtracted from the
calculated NPSHA result below thus reducing
the available head pressure.
Tests have demonstrated that the acceleration
pressure effect on NPSHA can be practically
canceled by locating a suction stabilizer in the
inlet line as close as possible to the pump
intake. Therefore, the use of suction
stabilizers on each pump is strongly
recommended.

H = Height of liquid above pump inlet


measured in feet.
P1

= Pressure in psig at pump inlet.

P2

= Pressure in psig at tank outlet.

Calculation of Net Positive Suction


Head Available
Example calculation of NPSHA (Net Positive
Suction Head Available)
Assume a pump installation with the following
as given. Calculate the NPSHA:
Pump elevation = Sea Level
Atmospheric pressure (Pa) = 14.7 psia
Fluid height in tank = 4.83 Ft.
Vapor pressure (Pv) of the pumped fluid = 1.7 psia
Calculated pipe and fittings pressure loss (Pf) = 0.1 psi
NPSHA

= Pa + H - Pf - Pv

NPSHA

= 14.7 psia + (4.83 ft./2.30) - 0.1 psi - 1.7 psia

NPSHA

= 14.7 psia + 2.1 psig - 1.8 psia

NPSHA

= 15 psia

To provide sufficient NPSHA, it is necessary


to determine the minimum height of liquid
required in the supply tank.
To determine H (minimum height of liquid
above pump inlet required ) solve the

Continue >
w w w. n a t o i l . c o m

Plunger Pump Technical Data


following:
H(ft)

= (NPSHR + Pv + Pf - Pa) X 2.31

H(ft)

H(ft)

= 5.1 psia X 2.31

H(ft)

= 12 f t.

(18 psia + 1.7 psia + 0.1 psi - 14.7 psia) X 2.31

It will be seen that as the barometric pressure


decreases, the level in the supply tank must
be increased to provide the same absolute
NPSHA at the pump inlet. If the vapor
pressure or pressure losses increase, the
supply tank level must be increased
proportionally to maintain the NPSHA.
The above calculations provide minimum
NPSHA; a good operating practice is to
provide an additional 5 to 10 feet of head
for contingencies.
Low Inlet Pressure
Where sufficient NPSH is not available,
increased inlet pressure may be obtained by
the use of an inlet charging centrifugal pump.
When calculating the centrifugal pump
requirements, the pump should be sized to
pump 1-1/2 to 2 times the discharge rate of
the plunger pump.
High Inlet Pressure
In single acting plunger pumps, high inlet
pressure actually increases the bearing loads
and for this reason a correction must be made
to the maximum discharge pressure rating for
a given plunger size if the suction pressure is
more than 5% of the discharge pressure.
For triplex pumps, the plunger size should
be determined on the basis of a calculated
artificial discharge pressure (Px) which is
equal to the actual discharge pressure (Pd)
plus one-half the actual inlet pressure (PI)
as shown below:
Px

= Pd + Pi
(for single acting triplex pumps)

For quintuplex pumps the artificial discharge


pressure should be the actual discharge
pressure plus two-thirds the actual suction
pressure.
Px

= Pd + 2/3 Pi
(for single acting quintuplex pumps)

The work performed by the pump, however,


is calculated in the usual manner using the

actual discharge pressure less the pump


suction pressure.

Suction And Discharge


Piping
Suction Piping Line
The suction line from the supply tank to the
pump must not be smaller than the inlet
connection of the pump; it should be short and
direct as practical and of sufficient diameter to
limit the fluid velocity to 1 to 2 feet/second. It
should be free of any restrictions and all
fittings should be full opening type with low
resistance to the fluid flow. Piping reductions
at the pump inlet should be made with an
eccentric reducer and installed such that the
transition from large to small is from the
bottom side of the pipe.

Discharge Piping Line


The discharge line must not be smaller than
the discharge connection at the pump; it
should be of a diameter sufficient to permit a
maximum fluid velocity of not more than 12
feet/second. This line should be streamlined
through gradual turns with friction not greater
than those caused by 45o long radius elbows.
Any bends directly adjacent to the pump
discharge should be avoided if at
all possible.

By-Pass Line
A by-pass valve and by-pass return line to
the supply tank is recommended for all
installations. This will permit no-load starting
and facilitate checking the pump and
prime mover.

Relief Valves
A relief valve must be mounted on the
discharge line as close to the pump as
possible. No other valve should be installed
between the pump and relief valve. The relief
valve must have adequate relieving capacity
and be set no higher than 1.25 times the rated
plunger working pressure. Relief discharge
should be piped back to the supply tank (not
the inlet line).

Continue >
4

w w w. n a t o i l . c o m

Plunger Pump Technical Data


Caution:
Be certain that all pipe, pipe fittings, hose,
etc., in the discharge line have working
pressure ratings equal to or greater than the
maximum pressure rating of the pump fluid
end.

Recommended Auxiliary
Equipment
Suction Stabilizer
As previously pointed out the use of a suction
stabilizer on each pump is recommended.
A simple vertical chamber with a closed top,
water level gauge and air charging connection
will perform satisfactorily as a suction stabilizer if properly pressurized with an air or gas
cushion on top of the fluid. Water absorbs air
and gas; therefore, this type of chamber
requires regular attention.
Commercial stabilizers, equipped with a
rubber diaphragm separating the air from the
fluid, are available and can be charged to a
predetermined pressure with air or nitrogen.
This charge will normally be retained for a
long period of time.

The need for pulsation dampeners is


increased where multiple pump installations
are involved. When two or more pumps are
discharging into a common header, the
normal pressure peaks of each pump may
occur simultaneously with the result that the
pressure peaks for the system will be
considerably higher than for a single pump.

Safety Devices
Low Fluid Level Controls
Pump operations under starved suction
conditions will result in severe knocking and
high shock pressures within the fluid end. For
this reason, a Low Fluid Level Controls shutdown should be provided on all installations to
protect the pump from operations with
insufficient fluid to fill the pump. The low fluid
level control sensor should be located on the
tank to assure the minimum NPSHA at the
pump inlet as described in Calculation on
Inlet System on the previous page.

Low Discharge Pressure


Shut-Down

Discharge Pulsation
Dampeners

A Low Discharge Pressure Shut-Down


device is recommended as a protection
against property damage due to discharge
line rupture.

A pulsation dampener should be installed


on each pump as close to the fluid end
as possible.

High Discharge Pressure


Shut-Down

All positive displacement reciprocating pumps


discharge fluid in a pulsating manner. The
harmonic relationship between the pump
speed, the piping system and other pumps in
the system may cause pulsations to be
amplified and result in transient pressure
peaks far in excess of the average discharge
pressure. These peaks are not always obvious
and seldom will be indicated on pressure
gauges.

High Discharge Pressure Shut-Down device


is recommended as extra insurance against
pump and equipment damage and the
possibility of personal injury should the relief
valve malfunction.

The pump may sound satisfactory with little or


no audible fluid knock but, such pressure
peaks subject the pump and piping system to
excessively high stresses. Many test have
shown that a pulsation dampener minimizes
these pressure peaks and contributes to
longer pump and valve life.

w w w. n a t o i l . c o m

Low Oil Pressure


Low Oil Pressure or low oil level shut-down is
strongly recommended to safeguard the pump
power end against lubrication failure.

Continue >

Plunger Pump Technical Data

Reference Tables
Equivalents of Liquid Measures and Weights

Liquid Measure
or
Weight
U.S. Gallon

U.S.
Gallon

Imperial
Gallon

U.S.
Pint

U.S.
Pound
Water*

0.833

Imperial Gallon

1.2009

9.60752

U.S. Pint

0.125

0.1501

1.042

0.01671

U.S. Pound Water*

0.11995

0.09992

0.09596

0.016035

U.S. Cubic Foot

7.48052

6.22888

U.S. Cubic Inch

0.004329

0.00361

*Water at 60o F.

59.8442
0.034632

8.337

U.S.
Cubic Foot

10

62.365

U.S.
Cubic Inch

0.13368

231

0.16054

277.42

0.03609

0.0005787

Inch
Water
(60o F)

Feet
Water
(60o F)

27.707

2.3039

28.875
27.708
1728
1

1 Barrel = 42 gallons (petroleum measure)

Reference Tables
Equivalents of Pressure and Head
Pressure
or
Head
Lb/In2
Lb/Ft2
Atmospheres

Lb/In2
1
0.0069445
14.696

Lb/Ft2

Atmospheres

144

0.068046

0.000473

2116.22

0.19241
407.17

0.01603
33.931

2.03601
0.014139
29.921

Inch Water*

0.036092

5.1972

0.002456

Feet Water*

0.433103

62.3668

0.029471

12

0.88180

Inch Mercury

0.491157

70.7266

0.033421

13.608

1.1340

*Water at 60o F.

0.08333

Inch
Mercury
(32o F)

0.073483

Mercury at 32o F

To convert from one set of units to another, locate the given unit in the left hand column, and multiply the numerical value by the factor shown horizontally to the right, under the set of units desired.

Continue >

w w w. n a t o i l . c o m

Plunger Pump Technical Data

Reference Tables
Equivalent Resistance of Valves and Fittings

KFactor
Nominal Pipe
Size Inches
1/
2
3/
4
1
11/4
11/2
2
21/2
3
4
5
6
8
10
12
14
16
18
20
24

Gate Valve
.22

Globe Valve
10

Inside
Dia. Inches
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
5.047
6.065
7.981
10.02
11.94
13.13
15.00
16.88
18.81
22.63

Angle Valve
5

45o Elbow
.42

90o Elbow
.90

180o Close Ret. Tee Thru Run Tee Thru Branch


2
.5
1.80

L = Equivalent Length of Schedule 40 Pipe in Feet


.41
.54
.69
.90
1.05
1.35
1.62
2.01
2.64
3.30
3.98
5.23
6.56
7.83
8.60
9.84
11.1
12.3
14.8

18.5
24.5
31.2
41.0
48.0
61.5
73.5
91.5
120
150
180
237
298
356
392
446
502
560
672

9.3
12.3
15.6
20.5
24.0
30.8
36.8
45.8
60.0
75.0
90.0
118.5
149
178
196
223
251
280
336

It is generally accepted that the pressure drop


Through valves and fittings is affected by the
same variables as the pressure drop through
straight pipe. This fact makes it possible to
express the resistance of valves and fittings
as being equivalent to a length of straight
pipe, and the approximate pressure drop for
the actual flow conditions can be determined
by using the formulas developed for
determining the pressure drop through straight
pipe.
Experimental data has shown that the
pressure drop through valves and fittings can
be expressed by the following equation:
2
h =K V
2g
The pressure drop for steady flow through
straight pipe is expressed by Fannings
equation:
2
h = f 4L x V
D
2g
By combining these two equations, the
pressure drop of a valve or fitting can be
converted to a length of a straight pipe.

.78
1.03
1.31
1.73
2.15
2.59
3.09
3.84
5.03
6.31
7.10
10.0
12.5
15.0
16.4
18.8
21.2
23.5
28.3

1.67
2.21
2.81
3.70
4.31
5.55
6.61
8.23
10.8
13.5
16.2
22.4
26.8
32.0
35.2
40.2
45.2
50.5
60.6

3.71
4.90
6.25
8.22
9.59
12.3
14.7
18.2
23.9
30.0
36.1
47.5
59.6
71.1
78.1
89.3
100
112
135

.93
1.23
1.56
2.06
2.40
3.08
3.68
4.57
6.00
7.51
9.05
11.9
14.9
17.8
19.5
22.4
25.2
28.0
33.7

3.33
4.41
5.62
7.40
8.63
11.6
13.2
16.4
21.6
27.0
32.5
42.8
53.7
64.0
70.4
80.5
90.5
101
121

2
2
K V = h = f 4L x V
2g
D
2g
L = Equivalent length of pipe in feet
D= Inside diameter in feet
d = Inside diameter in inches
K = Experimental coefficient for valve or fitting
f = Friction factor
Experimental data has shown that coefficient
K remains fairly constant for a specific type of
valve or fitting over a range of sizes. By using
an average friction factor based on a
Reynolds Number of 100,000, the equation:
K = f 4L becomes L = Kd
D
.336
and can be used to determine an approximate
equivalent length of pipe for a valve or fitting.
The values of equivalent length of straight
pipe for valves and fittings presented here
are based on a conservative evaluation of
published data and experimental tests. These
values are based on data obtained from the
flow of water through valves and fittings.

Continue >
w w w. n a t o i l . c o m

Plunger Pump Technical Data

Reference Tables
Flow of Water Through Schedule 40 Steel Pipe

Discharge

Pressure Drop per 100 feet and Velocity in Schedule 40 pipe for Water at 60 F.
Press.
Drop
Lbs
per
Sq. In.

Velocity
Gal.
Cub. Ft.
Feet
per
per
per
Minute Second Second

Velocity
Feet
per
Second

1/8"

Press.
Drop
Lbs
per
Sq. In.

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

Velocity
Feet
per
Second

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

Press.
Drop
Lbs
per
Sq. In.

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

1/4"
3/8"

1/2"

.2

0.000446

1.13

1.86

0.616

0.359

.3

0.000668

1.69

4.22

0.924

0.903

0.504

0.159

0.317

0.061

.4

0.000891

2.26

6.98

1.23

1.61

0.672

0.345

0.422

0.086

.5

0.00111

2.82

10.5

1.54

2.39

0.840

0.539

0.528

0.167

0.301

0.033

.6

0.00134

3.39

14.7

1.85

3.29

1.01

0.751

0.633

0.240

0.361

0.041

.8

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

3/4"

1"

0.00178

4.52

25.0

2.46

5.44

1.34

1.25

0.844

0.408

0.481

0.102

0.00223

5.65

37.2

3.08

8.28

1.68

1.85

1.06

0.600

0.602

0.155

0.371

0.048

0.00446

11.29

134.4

6.16

30.1

3.36

6.58

2.11

2.10

1.20

0.526

0.743

0.164

0.429

0.044

0.00668

9.25

64.1

5.04

13.9

3.17

4.33

1.81

1.09

1.114

0.336

0.644

0.090

0.473

0.00891

12.33

111.2

6.72

23.9

4.22

7.42

2.41

1.83

1.49

0.565

0.858

0.150

0.630

0.071

0.01114

8.40

36.7

5.28

3.01

2.75

1.86

0.835

1.073

0.223

0.788

0.104

0.01337

0.574

0.044

0.01782

0.765

0.073

10

0.02228

0.956

0.108

0.670

0.046

15

0.03342

1.43

0.224

1.01

0.094

2"
21/2"

11.2

11/4"
11/2"
0.043

10.08

51.9

6.33

15.8

3.61

3.84

2.23

1.17

1.29

0.309

0.946

0.145

13.44

91.1

8.45

27.7

4.81

6.60

2.97

1.99

1.72

0.518

1.26

0.241

10.56

42.4

3"
31/2"

3.71

2.99

2.15

0.774

1.58

0.361

9.03

6.02

21.6

9.99

5.57

6.36

3.22

1.63

2.37

0.755

12.03

37.8

7.43

10.9

4.29

2.78

3.16

1.28

9.28

16.7

5.37

4.22

3.94

1.93

11.14

23.8

6.44

5.92

4.73

2.72
3.64

20

0.04456

1.91

0.375

1.34

0.158

0.868

0.056

25

0.05570

2.39

0.561

1.68

0.234

1.09

0.083

0.812

0.041

30

0.06684

2.87

0.786

2.01

0.327

1.30

0.114

0.974

0.056

35

0.07798

3.35

1.05

2.35

0.436

1.52

0.151

1.14

0.704

0.882

0.041

12.99

32.2

7.51

7.90

5.52

40

0.08912

3.83

1.35

2.68

0.556

1.74

0.192

1.30

0.095

1.01

0.052

14.85

41.5

8.59

10.24

6.30

4.65

45

0.1003

4.30

1.67

3.02

0.668

1.95

0.239

1.46

0.117

1.13

0.064

9.67

12.80

7.09

5.85

50

0.1114

4.78

2.03

3.35

0.839

2.17

0.288

1.62

0.142

1.26

0.076

60

0.1337

5.74

2.87

4.02

1.18

2.60

0.406

1.95

0.204

1.51

0.107

70

0.1560

6.70

3.84

4.69

1.59

3.04

0.540

2.27

0.261

1.76

0.143

1.12

0.047

11.05

13.71

80

0.1782

7.65

4.97

5.36

2.03

3.47

0.687

2.60

0.334

2.02

0.180

1.28

0.060

12.62

17.59

4"

5"

10.74

15.66

7.88

7.15

12.89

22.2

9.47

10.21

6"

90

0.2005

8.60

6.20

6.03

2.53

3.91

0.861

2.92

0.416

2.27

0.224

1.44

0.074

14.20

22.0

100

0.2228

9.56

7.59

6.70

3.09

4.34

1.05

3.25

0.509

2.52

0.272

1.60

0.090

1.11

0.036

15.78

26.9

125

0.2785

11.97

11.76

8.38

4.71

5.43

1.61

4.06

0.769

3.15

0.415

2.01

0.135

1.39

0.055

19.72

41.4

150

0.3342

14.36

16.70

10.05

6.69

6.51

2.24

4.87

1.08

3.78

0.580

2.41

0.190

1.67

0.077

175

0.3899

16.75

22.3

11.73

8.97

7.60

3.00

5.68

1.44

4.41

0.774

2.81

0.253

1.94

0.102

200

0.4456

19.14

28.8

13.42

11.68

8.68

3.87

6.49

1.85

5.04

0.985

3.21

0.323

2.22

0.130

225

0.5013

15.09

14.63

9.77

4.83

7.30

2.32

5.67

1.23

3.61

0.401

2.50

0.162

1.44

0.043

250

0.557

10.85

5.93

8.12

2.84

6.30

1.46

4.01

0.495

2.78

0.195

1.60

0.051

275

0.6127

11.94

7.14

8.93

3.40

6.93

1.79

4.41

0.583

3.05

0.234

1.76

0.061

300

0.6684

13.00

8.36

9.74

4.02

7.56

2.11

4.81

0.683

3.33

0.275

1.92

0.072

325

0.7241

14.12

9.89

10.53

4.09

8.19

2.47

5.21

0.797

3.61

0.320

2.08

0.083

350

0.7798

11.36

5.41

8.82

2.84

5.62

0.919

3.89

0.367

2.24

0.095

375

0.8355

12.17

6.18

9.45

3.25

6.02

1.05

4.16

0.416

2.40

0.108

400

0.8912

12.98

7.03

10.08

3.68

6.42

1.19

4.44

0.471

2.56

0.121

8"

For Pipe lengths other than 100 feet, the presure drop is proportional to the length. Thus, for 50 feet of pipe, the pressure drop is approximately one-half the value given in the table...for 300
feet, three times the given value, etc.
Velocity is a function of the cross sectional flow area; thus, it is constant for a given flow rate and is independent of pipe length.

Continue >
8

w w w. n a t o i l . c o m

Plunger Pump Technical Data

Reference Tables
Flow of Water Through Schedule 40 Steel Pipe

Discharge

Pressure Drop per 100 feet and Velocity in Schedule 40 pipe for Water at 60 F.

Velocity
Gal.
Cub. Ft.
Feet
per
per
per
Minute Second Second

Press.
Drop
Lbs
per
Sq. In.

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

Velocity
Feet
per
Second

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

31/2"

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

4"

Press.
Drop
Lbs
per
Sq. In.

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

5"

Press.
Drop
Lbs
per
Sq. In.

Velocity
Feet
per
Second

6"

8"

425

0.9469

450

1.003

475

1.059

1.93

0.054

11.97

5.12

7.62

1.64

5.27

0.653

3.04

0.166

500

1.114

2.03

0.059

12.60

5.65

8.02

1.81

5.55

0.720

3.21

0.182

550

1.225

2.24

0.071

13.85

6.79

8.82

2.17

6.11

0.861

3.53

0.219

600

1.337

2.44

0.083

15.12

8.04

9.63

2.55

6.66

1.02

3.85

0.258

650

1.448

2.64

0.097

10.43

2.98

7.22

1.18

4.17

0.301

700

1.560

2.85

0.112

2.01

0.047

11.23

3.43

7.78

1.35

4.49

0.343

750

1.671

3.05

0.127

2.05

0.054

12.03

3.92

8.33

1.55

4.81

0.392

800

1.782

3.25

0.143

2.29

0.061

12.83

4.43

8.88

1.75

5.13

0.443

850

1.894

3.46

0.160

2.44

0.068

2.02

0.042

13.64

5.00

9.44

1.96

5.45

0.497

900

2.005

3.66

0.179

2.58

0.075

2.13

0.047

14.44

5.58

9.99

2.18

5.77

0.554

950

2.117

3.86

0.198

2.72

0.083

2.25

0.052

15.24

6.21

10.55

2.42

6.09

0.613

1,000

2.228

4.07

0.218

2.87

0.091

2.37

0.057

16.04

6.84

11.10

2.68

6.41

0.675

1,100

2.451

4.48

0.260

3.15

0.110

2.61

0.068

17.65

8.23

12.22

3.22

7.05

0.807

1,200

2.674

4.88

0.306

3.44

0.128

2.85

0.080

2.18

0.042

13.33

3.81

7.70

0.948

1,300

2.896

5.29

0.355

3.73

0.150

3.08

0.093

2.36

0.048

14.43

4.45

8.33

1.11

1,400

3.119

5.70

0.409

4.01

0.171

3.32

0.107

2.54

0.055

15.55

5.13

8.98

1.28

1,500

3.342

6.10

0.466

4.30

0.195

3.56

0.122

2.72

0.063

1,600

3.565

6.51

0.527

4.59

0.219

3.79

0.139

2.90

0.071

1,800

4.010

7.32

0.663

5.16

0.276

4.27

0.172

3.27

0.088

2.58

0.050

19.99

2,000

4.456

8.14

0.808

5.73

0.336

4.74

0.209

3.63

0.107

2.87

0.060

22.21

2,500

5.570

10.17

1.24

7.17

0.515

5.93

0.321

4.54

0.163

3.59

0.091

3,000

6.684

12.20

1.76

8.60

0.731

7.11

0.451

5.45

0.232

4.30

0.129

3.46

0.075

3,500

7.798

14.24

2.38

10.03

0.982

8.30

0.607

6.35

0.312

5.02

0.173

4.04

0.101

8.912

4,000

10"

13.80

7.89

10.71

4.12

6.82

1.33

4.72

0.529

2.73

0.136

14.61

8.80

11.34

4.60

7.22

1.48

5.00

0.590

2.89

0.151

12"

14"

16"

18"

16.66

5.85

9.62

1.46

17.77

6.61

10.26

1.65

8.37
10.3

20"
24"

11.54

2.08

12.82

2.55

16.03

3.94

19.24

5.59

22.44

7.56

16.27

3.08

11.47

1.27

9.48

0.787

7.26

0.401

5.74

0.222

4.62

0.129

3.19

0.052

25.65

10.03

18.31

3.87

12.90

1.60

10.67

0.990

8.17

0.503

6.46

0.280

5.20

0.162

3.59

0.065

28.87

5,000

11.14

20.35

4.71

14.33

1.95

11.85

1.21

9.08

0.617

7.17

0.340

5.77

0.199

3.99

0.079

6,000

13.37

24.41

6.74

17.20

2.77

14.23

1.71

10.89

0.877

8.61

0.483

6.93

0.280

4.79

0.111

7,000

15.60

28.49

9.11

8,000

17.82

4,500

20.07

3.74

16.60

2.31

12.71

1.18

10.04

0.652

8.08

0.376

5.59

0.150

22.93

4.84

18.96

2.99

14.52

1.51

11.47

0.839

9.23

0.488

6.38

0.192
0.242

9,000

20.05

25.79

6.09

21.34

3.76

16.34

1.90

12.91

1.05

10.39

0.608

7.18

10,000

22.28

28.66

7.46

23.71

4.61

18.15

2.34

14.34

1.28

11.54

0.739

7.98

0.294

12,000

26.74

34.40

28.45

6.59

21.79

3.33

17.21

1.83

13.85

1.06

9.58

0.416

14,000

31.19

33.19

8.89

25.42

4.49

20.08

2.45

16.16

1.43

11.17

0.562

16,000

35.65

29.05

5.83

22.95

3.18

18.47

1.85

12.77

0.723

18,000

40.10

32.68

7.31

25.82

4.03

20.77

2.32

14.36

0.907

20,000

44.56

36.31

9.03

28.69

4.93

23.08

2.86

15.96

1.12

10.7

9.80
12.2

For Pipe lengths other than 100 feet, the pressure drop is proportional to the length. Thus, for 50 feet of pipe, the pressure drop is approximately one-half the value given in the table...for 300
feet, three times the given value, etc.
Velocity is a function of the cross sectional flow area; thus, it is constant for a given flow rate and is independent of pipe length.

Continue >
w w w. n a t o i l . c o m

Plunger Pump Technical Data

Reference Tables
Vapor Pressure or Saturation Presure of Water*
(cont.)
Temp.
Deg. F.

psi
Absolute

Inches
Mercury

Feet Of
Head

Temp.
Deg. F.

32

.08854

.1806

.2048

112

1.3504

2.7494

3.117

34

.09610

.1957

.2219

114

1.4298

2.9111

3.299

36

.10412

.2120

.2404

116

1.5130

3.0806

3.490

38

.11256

.2291

.2599

118

1.6006

3.2589

3.695

40

.12170

.2478

.2810

120

1.6924

3.4458

3.907

42

.13149

.3180

.3036

122

1.7888

3.6420

4.121

44

.14197

.2890

.3278

124

1.8897

3.8475

4.354

46

.15319

.3119

.3537

126

1.9955

4.0629

4.597

48

.16523

.3364

.3815

128

2.1064

4.2887

4.853

50

.17811

.3626

.4110

130

2.2225

4.5251

5.128

52

.19182

.3906

.4428

132

2.3440

4.7725

5.400

54

.20642

.4203

.4763

134

2.4712

5.0314

5.693

56

.2220

.4520

.5123

136

2.6042

5.3022

6.000

58

.2386

.5218

.5504

138

2.7432

5.5852

6.320

60

.2563

.5218

.5913

140

2.8886

5.8812

6.666

62

.2751

.5601

.6347

142

3.0440

6.1903

7.013

64

.2951

.6009

.6809

144

3.1990

6.5132

7.307

66

.3164

.6442

.7301

146

3.365

6.850

7.753

68

.3390

.6903

.7822

148

3.537

7.202

8.149

70

.3631

.7392

.8377

150

3.718

7.569

8.566

72

.3886

.7912

.8965

160

4.741

9.653

10.923

74

.4156

.8462

.9589

170

5.992

12.200

13.805

76

.4443

.9046

1.025

180

7.510

15.290

17.302

78

.4747

.9666

1.095

190

9.339

19.014

21.516

80

.5069

1.0321

1.170

200

11.526

23.467

26.555

82

.5410

1.1016

1.249

210

14.123

28.755

32.538

84

.5771

1.1750

1.332

212

14.696

29.921

33.858

86

.6152

1.2527

1.421

220

17.186

34.991

39.595

88

.6556

1.3347

1.514

240

24.969

50.837

57.526

90

.6982

1.4215

1.611

260

35.429

72.134

81.625

92

.7432

1.5131

1.716

280

49.203

100.178

113.359

94

.7906

1.6097

1.825

300

67.013

136.439

154.391

96

.8407

1.7117

1.940

350

134.63

274.108

310.147

98

.9835

1.8192

2.062

400

247.31

503.526

569.778

100

.9492

1.9325

2.191

450

422.6

860.418

973.628

102

1.0078

2.0519

2.326

500

680.8

1386.156

1568.495

104

1.0695

2.1775

2.468

550

1045.2

2128.038

2408.036

106

1.1345

2.3099

2.617

600

1542.9

3141.360

3554.687

108

1.2029

2.4491

2.775

700

3093.7

6298.804

7127.575

110

1.2748

2.5955

2.942

*Specific Gravity of Water at 60O F = 1.00

10

psi
Absolute

Inches
Mercury

Feet Of
Head

Continue >

w w w. n a t o i l . c o m

Plunger Pump Technical Data

Reference Tables
Approximate Atmospheric Pressures and Barometer Readings at Different Altitudes

Altitude
Feet

Atmospheric Pressure
PSIA

Barometer
Inches Mercury

Head In Feet
Of Water*

-1,000

15.2

31.02

35.07

-500

15.0

30.62

34.61

14.696

30.004

33.92

+500

14.4

29.39

33.23

+1,000

14.2

28.98

32.77

1,500

13.9

28.37

32.07

2,000

13.7

27.96

31.61

2,500

13.4

27.35

30.92

3,000

13.2

26.94

30.46

3,500

12.9

26.33

29.77

4,000

12.7

25.92

29.31

4,500

12.4

25.31

28.61

5,000

12.2

24.90

28.15

5,500

12.0

24.49

27.69

6,000

11.8

24.08

27.23

6,500

11.5

23.47

26.54

7,000

11.3

23.06

26.07

7,500

11.1

22.66

25.61

8,000

10.9

22.24

25.15

8,500

10.7

21.84

24.69

9,000

10.5

21.43

24.23

9,500

10.3

21.02

23.77

10,000

10.1

20.62

23.31

15,000

8.3

16.94

19.15

20,000

6.7

13.68

15.46

*Water at 60o F.

w w w. n a t o i l . c o m

Continue >

11

Plunger Pump Technical Data

2
10

1
3

1 Lubrication:
splash or force-fed
Most NATIONAL OILWELL pumps use the
proven splash lubrication system. Models for
high horsepower requirements incorporate
both splash and pressurized systems. The
pressurized system is also available for lowspeed and severe service applications.

2 Plunger systems
The finish of each plunger is computer
controlled and monitored to assure extended
packing life. Plungers are available with a
variety of surfaces including:
Ceramic
Spray metal
Carbide-coated spray metal
To handle most fluids and pressures, packing
options include:
Spring-loaded Kevlar
Non-adjustable lip-type
Adjustable die-formed
Spring-loaded V-ring
For high-pressure, high-temperature, and
exotic fluids, special packing materials are
available.

5
6

7
8

3 Power end is designed for


long life and ease of service
Precision bearings mounted to high strength
crankshaft, ductile iron marine type connecting
rods, and fully cylindrical cross heads (on
models up to 8-inch stroke) are combined in a
rugged, cast power frame for structural reliability
and ease of servicing.

4 Double extension crankshaft


on select models
This permits drive input from either side
without reversing the crankshaft. You can also
connect auxiliary drives for chemical, sump,
charging, or lubricating pumps, in addition to
the regular drive.

5 Replaceable intermediate rod


Corrosion-resistant chrome-plated or stainless
steel intermediate rods can be replaced
without removing the crosshead.

Continue >
12

w w w. n a t o i l . c o m

Plunger Pump Technical Data

1
3

10

8
3

6
5
6

7
8

8 Fluid ends
6 Valve service
Shouldered, tapered-seat stainless steel
valves provide a positive and controlled fit.
For high pressure service and other special
requirements, valve choices include:

Cage-type with ball and seat


Cage-type with disc and seat
Bottom guided
Disc type

For greater corrosion and abrasion resistance,


optional valve materials include:
5 choices of stainless steels
Delrin plastic
Carburized steel

7 Long-Life plungers
and packing
The stuffing boxes fit in a pilot bore in the ribreinforced main frame, assuring proper
alignment of the plungers and stuffing boxes.
Packing and plunger life can be further
extended with an easily installed drip or forcefed lubrication system.

Fluid ends are available for low medium, and


high pressure applications. Materials can be
furnished to handle fluids of all types. A partial
list includes:
Aluminum bronze
316 stainless steel
Ductile Ni-resist
Inconel
17-4 PH stainless steel
Duplex 5.5
Ductile iron
Cast & forged steel

9 Gear reducers
For direct connecting high speed drives,
integral gear reducers are available for most
pumps. Other models incorporate an internal
pinion shaft which provides great flexibility for
changes in pumping conditions.

10 Easy access to plungers


and stuffing boxes
Ample space in the cradle chamber makes
maintenance easier. Plungers can be
removed or packing replaced without
removing stuffing boxes.

w w w. n a t o i l . c o m

13

Horsepower Calculator

To find Hydraulic & Brake Horsepower answer questions a & b or a & c below:

English Units

(to use bbl/day, gpm must be zero)

Calculate

Reset

Calculate

Reset

a. Maximum discharge pressure in psi 0


b. Maximum required flow in gpm 0
or
c. Maximum required flow in bbl/day 0
Hydraulic Horsepower is 0
Brake Horsepower Required 0

Metric Units

(to use m3/day, l/m must be zero)

a. Maximum discharge pressure in kPa 0


b. Maximum required flow in l/m 0
or
c. Maximum required flow in m3/day 0

Hydraulic Kilowatts is 0
Kilowatts Required 0

(Hydraulic Horsepower is 0
(Brake Horsepower is 0

)
)

Example:
Using a maximum discharge pressure of 2500 psi and a maximum required flow of 100 gpm,
the hydraulic horsepower is 146, the brake horsepower is 162.
The result of the above calculation would indicate you need a pump capable of 162 bhp or above
to do the job. You then choose the smallest pump that will do the job effectively starting in this
case with the 165T-5.
Look at the max discharge pressure column in the 165T ratings. Find the pressure equal to
or the next one greater than 2500 psi. Move across the row to determine if the pump can deliver
100 gpm within the listed pump speed range. Notice that the 165T is just short of being able
to do the job. Go to the next larger pump and repeat the process. You'll then find the 200T is
capable of doing the job utilizing a 2 1/4" plunger running in the 400 rpm range.

Continuous

Continue

Continuous Duty Pumps

Duty Pumps

8S-25

Simplex Plunger Pump


Rated input horsepower

"S" Simplex
Stroke length (in.)

This 2 1/2" stroke pump is


designed for a variety of
fluid transfer applications.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
8S-25

1-1/4 (31.8) FNP Threaded.

Dimensions
Suction Connection Size
2" (50.8) FNP Threaded.

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ......2 x 2-1/2 (50.8 x 63.5)
Rated BHP At 450 RPM (Kw) ..........................................................................8 (6)
Rated Plunger Load, pounds (Kg).......................................................2,560 (1162)
Maximum Working Pressure: PSI (kPa) ........................................2,350 (16,192)
Crankshaft Extension: in. (mm) ................................................................2 (50.8)
Weight: - Lbs. (Kg)
Pump Only On Wood Shipping Skids.........................................................160 (64)

Pump Type
8S-25

Length

Width

Height

31"

11"

10-3/4"

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze Stuffing Boxes & Nuts
Bronze Stuffing Box Internals
Ceramic or Metal Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Chamber Cover
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

8S-25/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
(Sq. In.)

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

29
46
66
89
117

0.85
1.33
1.91
2.60
3.40

44
68
98
134
175

1.28
1.99
2.87
3.90
5.10

58
91
131
179
233

1.70
2.66
3.83
5.21
6.80

73
114
164
223
292

2.13
3.32
4.78
6.51
8.50

87
137
197
268
350

2.55
3.98
5.74
7.81
10.20

102
159
230
313
408

2.98
4.65
6.69
9.11
11.90

117
182
262
357
466

3.40
5.31
7.65
10.41
13.60

131
205
295
402
525

3.83
5.98
8.61
11.71
15.30

8S-25
1
1 1/4
1 1/2
1 3/4
2

0.7854 0.2916 0.0085 2350


1.2272 0.4555 0.0133 2086
1.7672 0.6560 0.0191 1449
2.4053 0.8929 0.0260 1064
3.1416 1.1662 0.0340 815
Brake Horsepower Required1.8

2.7

3.6

4.5

5.4

6.3

7.2

8.0

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min. Max.
Per Press.
RPM
kPa

100 RPM
M3/D

L/Min.

150 RPM
M3/D
7
11
16
21
28

200 RPM

L/Min.

M3/D

4.83
7.54
10.86
14.78
19.30

9
14
21
28
37

250 RPM

L/Min.

M3/D

6.43
10.05
14.48
19.71
25.74

12
18
26
35
46

300 RPM

L/Min.

M3/D

8.04
12.57
18.10
24.63
32.17

14
22
31
43
56

350 RPM

GPM

M3/D

9.65
15.08
21.72
29.56
38.61

16
25
37
50
65

400 RPM

450 RPM

L/Min.

M3/D

L/Min.

M3/D

11.26
17.59
25.34
34.48
45.04

19
29
42
57
74

12.87
20.11
28.96
39.41
51.48

21
33
47
64
83

L/Min.

8S-25
25
32
38
44
51

5.0671 0.0464 0.0322


7.9174 0.0724 0.0503
11.4010 0.1043 0.0724
15.5180 0.1420 0.0985
20.2684 0.1854 0.1287
Kilowatts Required

16,203
14,382
9,991
7,336
5,619

5
7
10
14
19

3.22
5.03
7.24
9.85
12.87
1.3

2.0

2.7

3.3

4.0

4.7

5.3

14.48
22.62
32.57
44.34
57.91
5.9

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

14D-25

Duplex Plunger Pump

Rated input horsepower


"D" Duplex
Stroke length (in.)

This 2 1/2" stroke pump is


designed for a variety of
fluid transfer applications.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
14D-25

1-1/4 (31.8) FNP Threaded.

Dimensions
Suction Connection Size
2"(50.8) FNP Threaded.

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) .......2 x 2-1/2 (50.8 x 63.5)
Rated BHP At 400 RPM (Kw) ...................................................................14 (10.5)
Rated Plunger Load, pounds (Kg).......................................................2,560 (1162)
Maximum Working Pressure: PSI (kPa) ........................................2,350 (16,192)
Crankshaft Extension: in. (mm) ................................................................2 (50.8)
Weight: - Lbs. (Kg)
Pump Only On Wood Shipping Skids....................................................320 (103.5)

Pump Type
14D-25

Length

Width

Height

31"

14-1/2"

10-3/4"

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze Stuffing Boxes & Nuts
Bronze Stuffing Box Internals
Ceramic or Metal Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Chamber Cover
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

14D-25/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

58
91
131
179
233

1.70
2.66
3.83
5.21
6.80

87
137
197
268
350

2.55
3.98
5.74
7.81
10.20

117
182
262
357
466

3.40
5.31
7.65
10.41
13.60

146
228
328
446
583

4.25
6.64
9.56
13.02
17.00

175
273
394
536
700

5.10
7.97
11.48
15.62
20.40

204
319
459
625
816

5.95
9.30
13.39
18.22
23.80
12.6

233
364
525
714
933

6.80
10.63
15.30
20.83
27.20

14D-25
1
1 1/4
1 1/2
1 3/4
2

0.7854 0.5831 0.0170 2350


1.2272 0.9111 0.0266 2086
1.7672 1.3120 0.0383 1449
2.4053 1.7857 0.0521 1064
3.1416 2.3324 0.0680
815
Brake Horsepower Required:

3.6

5.4

7.2

9.0

10.8

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

14

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

350 RPM

400 RPM

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

M3/D

5.0671 0.0927 0.0643


7.9174 0.1449 0.1005
11.4010 0.2086 0.1448
15.5180 0.2839 0.1971
20.2684 0.3708 0.2574
Kilowatts Required:

16,203
14,382
9,991
7,336
5,619

9
14
21
28
37

6.43
10.05
14.48
19.71
25.74

14
22
31
43
56

9.65
15.08
21.72
29.56
38.61

19
29
42
57
74

12.87
20.11
28.96
39.41
51.48

23
36
52
71
93

16.09
25.13
36.19
49.26
64.35

28
43
63
85
111

19.30
30.16
43.43
59.12
77.21

32
51
73
99
130

22.52
35.19
50.67
68.97
90.08

37
58
83
114
148

L/Min.

14D-25
25
32
38
44
51

2.7

4.0

5.4

6.7

8.0

9.4

25.74
40.22
57.91
78.82
102.95
10.4

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Triplex Plunger Pump

15T-15

Rated input horsepower


"T" Triplex
Stroke length (in.)

This 1-1/2" stroke pump is


designed for a variety of
fluid transfer applications.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
15T-15

3/4" (19.05) FNP Threaded

Suction Connection Size


1-1/2" (38.1) FNP Threaded

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) .1-1/2 x 1-1/2 (38.1 x 38.1)
Rated BHP At 750 RPM (Kw) .................................................................15 (11.25)
Rated Plunger Load, pounds (Kg).........................................................1,600 (720)
Maximum Working Pressure: PSI (kPa) ........................................5,215 (25,838)
Crankshaft Extension: in. (mm) ........................................................1 1/8 (28.58)
Weight: - Lbs. (Kg)
Pump Only On Wood Shipping Skids.........................................................115 (52)

Dimensions
Pump Type

Length

Width

Height

15T-15

18-5/16"

9-1/2"

71/4"

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze Stuffing Boxes & Nuts
Bronze Stuffing Box Internals
Ceramic or Metal Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Chamber Cover
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

15T-15/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
(Sq. In.)

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

30
52
82
118

0.86
1.53
2.39
3.44

44
79
123
177

1.29
2.3
3.59
5.16

59
105
164
236

1.72
3.06
4.78
6.89

74
131
205
295

2.15
3.83
5.98
8.61

89
157
246
354

2.58
4.59
7.17
10.33

103
184
287
413

3.01
5.36
8.37
12.05

118
210
328
472

3.44
6.12
9.56
13.77

15T-15
3/4
1
1 1/4
1 1/2

0.4418 0.2952 0.0086 3622


0.7854 0.5248 0.0153 2037
1.2272 0.82 0.0239 1304
1.7672 1.1808 0.0344
905
Brake Horsepower Required:

450 RPM

500 RPM

550 RPM

600 RPM

650 RPM

700 RPM

750 RPM

English Units (cont.)


Plunger Plunger
Dia.
Area
In.
(Sq. In.)

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

133
236
369
531

3.87
6.89
10.76
15.49

148
262
410
590

4.3
7.65
11.95
17.21

162
289
451
649

4.73
8.42
13.15
18.93

177
315
492
708

5.16
9.18
14.34
20.66

192
341
533
768

5.59
9.95
15.54
22.38

207
367
574
827

6.02
10.71
16.73
24.1

221
394
615
886

6.45
11.48
17.93
25.82

15T-15
3/4
1
1 1/4
1 1/2

0.4418 0.2952 0.0086 3622


0.7854 0.5248 0.0153 2037
1.2272 0.82 0.0239 1304
1.7672 1.1808 0.0344
905
Brake Horsepower Required:

10

11

12

13

14

15

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

M3/D

L/Min.

2.8502 0.0469 0.0326


5.0671 0.0834 0.0579
7.9174 0.1304 0.0905
11.401 0.1877 0.1303
Kilowatts Required:

24,973
14,045
8,991
6,240

5
8
13
19

3.26
5.79
9.05
13.03

7
13
20
28

4.89
8.69
13.57
19.54

9
17
26
38

6.51
11.58
18.1
26.06

12
21
33
47

8.14
14.48
22.62
32.57

14
25
39
56

9.77
17.37
27.15
39.09

16
29
46
66

11.4
20.27
31.67
45.6

19
33
52
75

13.03
23.16
36.19
52.12

15T-15
19
25
32
38

1.5

2.3

3.8

4.5

5.3

450 RPM

500 RPM

550 RPM

600 RPM

650 RPM

700 RPM

750 RPM

Metric Units (cont.)


Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

2.8502 0.0469 0.0326


5.0671 0.0834 0.0579
7.9174 0.1304 0.0905
11.401 0.1877 0.1303
Kilowatts Required:

24,973
14,045
8,991
6,240

21
38
59
84

14.66
26.06
40.72
58.63

23
42
65
94

16.29
28.96
45.24
65.15

26
46
72
103

17.92
31.85
49.77
71.66

28
50
78
113

19.54
34.75
54.29
78.18

31
54
85
122

21.17
37.64
58.82
84.69

33
58
91
131

L/Min.

M3/D

22.8
40.54
63.34
91.21
10.5

35
63
98
141

L/Min.

15T-15
19
25
32
38

6.8

7.5

8.3

9.8

24.43
43.43
67.86
97.72
11.3

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

20T-25

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)

This 2 1/2" stroke pump is


designed for a variety of
fluid transfer applications.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
20T-25

1-1/4 (31.8) FNP Threaded.

Suction Connection Size


2 (50.8) FNP Threaded.

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ......2 x 2-1/2 (50.8 x 63.5)
Rated BHP At 400 RPM (Kw) ......................................................................20 (15)
Rated Plunger Load, pounds (Kg).......................................................2,560 (1162)
Maximum Working Pressure: PSI (kPa) ........................................2,350 (16,192)
Crankshaft Extension: in. (mm) ................................................................2 (50.8)
Weight: - Lbs. (Kg)
Pump Only On Wood Shipping Skids.......................................................340 (153)

Dimensions
Pump Type
20T-25

Length

Width

Height

31"

17"

10-3/4"

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze Stuffing Boxes & Nuts
Bronze Stuffing Box Internals
Ceramic or Metal Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Chamber Cover
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

20T-25/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
(Sq. In.)

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

87
137
197
268
350

2.55
3.98
5.74
7.81
10.20

131
205
295
402
525

3.83
5.98
8.61
11.71
15.30

175
273
394
536
700

5.10
7.97
11.48
15.62
20.40
10.8

219
342
492
670
875

6.38
9.96
14.34
19.52
25.50
13.5

262
410
590
804
1050

7.65
11.95
17.21
23.43
30.60

350
547
787
1071
1399

10.20
15.94
22.95
31.24
40.80

16.1

306
8.93
478
13.95
689
20.08
938
27.33
1225 35.70
18.9

300 RPM

350 RPM

20T-25
1
1 1/4
1 1/2
1 3/4
2

0.7854 0.8747 0.0255 2350


1.2272 1.3666 0.0398 2086
1.7672 1.9680 0.0574 1449
2.4053 2.6786 0.0781 1064
3.1416 3.4986 0.1020
815
Brake Horsepower Required:

5.4

8.0

100 RPM

150 RPM

20

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

200 RPM

250 RPM

400 RPM

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

M3/D

L/Min.

5.0671 0.1391 0.0965


7.9174 0.2173 0.1508
11.4010 0.3129 0.2172
15.5180 0.4259 0.2956
20.2684 0.5562 0.3861
Kilowatts Required:

16,203
14,382
9,991
7,336
5,619

14
22
31
43
56

9.65
15.08
21.72
29.56
38.61

21
33
47
64
83

14.48
22.62
32.57
44.34
57.91

28
43
63
85
111

19.30
30.16
43.43
59.12
77.21

35
54
78
106
139

24.13
37.70
54.29
73.90
96.52

42
65
94
128
167

28.96
45.24
65.15
88.68
115.82

49
76
110
149
195

33.78
52.78
76.01
103.45
135.12

56
87
125
170
222

38.61
60.32
86.87
118.23
154.43
15

20T-25
25
32
38
44
51

10

12

14

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Triplex Plunger Pump

29T-3

Rated input horsepower


"T" Triplex
Stroke length (in.)

This 3" stroke pump is


designed for a variety of
fluid transfer applications.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
29T-3

1-1/2 (38.1) FNP Threaded.

Dimensions
Suction Connection Size
2-1/2" (63.5) FNP Threaded.

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ......2-1/2 x 3 (63.5 x 76.2)
Rated BHP At 400 RPM (Kw) .................................................................29 (21.75)
Rated Plunger Load, pounds (Kg).......................................................2,950 (1162)
Maximum Working Pressure: PSI (kPa) ........................................2,350 (16,192)
Crankshaft Extension: in. (mm) ..........................................................2-1/2 (63.5)
Weight: - Lbs. (Kg)
Pump Only On Wood Shipping Skids.......................................................800 (360)

Pump Type

Length

Width

Height

29T-3

37-1/2"

24-1/2"

13"

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze Stuffing Boxes & Nuts
Bronze Stuffing Box Internals
Ceramic or Metal Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Chamber Cover
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

29T-3/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
(Sq. In.)

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

164
236
321
420
531
656

4.78
6.89
9.37
12.24
15.49
19.13

246
354
482
630
797
984

7.17
10.33
14.06
18.36
23.24
28.69
11.3

328
472
643
840
1063
1312

9.56
13.77
18.74
24.48
30.98
38.25
15.2

410
590
804
1050
1328
1640

11.95
17.21
23.43
30.60
38.73
47.81
18.9

492
708
964
1259
1594
1968

14.34
20.66
28.11
36.72
46.47
57.38

656
945
1286
1679
2125
2624

22.7

574
16.73
827
24.10
1125 32.80
1469 42.84
1860 54.22
2296 66.94
26.5

19.13
27.54
37.49
48.96
61.97
76.50
29.0

300 RPM

350 RPM

29T-3
1 1/4
1 1/2
1 3/4
2
2 1/4
2 1/2

1.2272 1.6400 0.0478 2350


1.7672 2.3616 0.0689 1698
2.4053 3.2143 0.0937 1247
3.1416 4.1983 0.1224
955
3.9761 5.3135 0.1549
755
4.9088 6.5599 0.1913
611
Brake Horsepower Required:

7.57

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

100 RPM

150 RPM

200 RPM

250 RPM

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

7.9174 0.2607 0.1810


11.4010 0.3755 0.2606
15.5180 0.5110 0.3547
20.2684 0.6675 0.4633
25.6522 0.8448 0.5863
31.6694 1.0430 0.7239
Kilowatts Required:

16,203
11,707
8,598
6,584
5,206
4,213

26
38
51
67
84
104

18.10
26.06
35.47
46.33
58.63
72.39

39
56
77
100
127
156

27.15
39.09
53.21
69.49
87.95
108.58
8.4

52
75
102
133
169
209

36.19
52.12
70.94
92.66
117.27
144.78
11.3

65
94
128
167
211
261

L/Min.

M3/D

45.24
65.15
88.68
115.82
146.59
180.97
14.0

78
113
153
200
253
313

GPM

M3/D

400 RPM

L/Min.

M3/D

63.34
91.21
124.15
162.15
205.22
253.36
19.8

104
150
204
267
338
417

L/Min.

29T-3
32
38
44
51
57
64

5.7

54.29
78.18
106.41
138.99
175.90
217.16
16.9

91
131
179
234
296
365

72.39
104.24
141.88
185.31
234.54
289.55
21.6

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly J-30

30T-2 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges "L" Low, "H" High

This 2" stroke pump is


designed for a variety of fluid
transfer applications operating
at low, or high pressures.
Performance Data >

Dimensions

Field Connections in. (mm)


Pump Model
Discharge Connection Size

Suction Connection Size

Pump Type

Length

Width

Height

30T-2L Threaded

1-1/2 (38.10) Int. Pipe Thds.

2-1/2 (63.5) Int. Pipe Thds.

30T-2L Threaded

34-7/8"

28-1/4"

11"

30T-2L

1-1/2 (38.10) API-2000# RTJ

2-1/2 (63.5) ANSI-150 F.F.

30T-2L Flanged

34-7//8"

28-1/4"

11"

30T-2H

1 (25.4) ANSI-2500 RTJ

2 (50.8) ANSI-300 F.F.

30T-2H Flanged

34-7/8"

28-1/4"

11"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ......2-1/4 x 2 (57.2 x 50.8)
Rated BHP At 500 RPM (Kw) ...................................................................30 (22.4)
Rated Plunger Load, pounds (Kg).......................................................3,565 (1617)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure .........................................................2,000 (13,788)
"H" Model Discharge Pressure.........................................................5,000 (34,470)
Crankshaft Extension: in. (mm)
Diameter ..................................................................................................2.5 (63.5)
Length .............................................................................................4-15/16 (125.4)
Keyway (Width x Depth) ...................................................5/8 x 5/16 (15.88 x 7.94)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ............................................................1.75 (44.45)
Length.............................................................3-13/16 (96.8)
Keyway (Width x Depth) ...................1/2 x 1/4 (12.7 x 6.35)
Direct Drive: Diameter ............................................................1.75 (44.45)
Length...............................................................3-3/16 (96.8)
Keyway (Width x Depth) ......................1/2 x 1/4 (12.7 x 6.4)
Oil Capacity: Gallons (L)
Crankcase .................................................................................................1.2 (4.5)
Gear Unit (Varies with Ratio)......................................................................2/3 (2.5)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) .......................640 (290)
Gear Unit - Lbs. (Kg) ...........................................................................300 (136.08)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
3.50:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

30T-2/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
(Sq. In.)

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

500 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

1.5744
2.1429
2.7989
3.5423

0.0459
0.0625
0.0816
0.1033

2000
1482
1134
896

315
429
560
708

9.18
12.50
16.32
20.66

394
536
700
886

11.48
15.62
20.40
25.82

472
643
840
1063

13.77
18.74
24.48
30.98

551
750
980
1240

16.07
21.87
28.56
36.15

630
857
1120
1417

18.36
24.99
32.64
41.31

708
964
1259
1594

20.66
28.11
36.72
46.47

787
1071
1399
1771

22.95
31.24
40.80
51.64

0.6910 0.6156 0.0179 5000


0.7854 0.6997 0.0204 4538
1.2272 1.0933 0.0319 2904
1.7672 1.5744 0.0459 2017
Brake Horsepower Required:

123
140
219
315

3.59
4.08
6.38
9.18

154
175
273
394

4.48
5.10
7.97
11.48

184
210
328
472

5.38
6.12
9.56
13.77

215
245
383
551

6.28
7.14
11.16
16.07

246
280
437
630

7.17
8.16
12.75
18.36

277
315
492
708

8.07
9.18
14.34
20.66

307
350
547
787

8.96
10.20
15.94
22.95

30T-2L
1 1/2
1 3/4
2
2 1/4

1.7671
2.4053
3.1416
3.9761

30T-2H
15/16
1
1 1/4
1 1/2

12

15

18

21

24

27

30

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

500 RPM

Metric Units
M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

M3/D

L/Min.

0.2503
0.3407
0.4450
0.5632

0.1737
0.2365
0.3089
0.3909

13788
10215
7821
6180

50
68
89
113

34.75
47.29
61.77
78.18

63
85
111
141

43.43
59.12
77.21
97.72

75
102
133
169

52.12
70.94
92.66
117.27

88
119
156
197

60.81
82.76
108.10
136.81

100
136
178
225

69.49
94.59
123.54
156.36

113
153
200
253

78.18
106.41
138.99
175.90

125
170
222
282

86.87
118.23
154.43
195.45

4.4535 0.0978 0.0679


5.0671 0.1112 0.0772
7.9174 0.1738 0.1206
11.4010 0.2503 0.1737
Kilowatts Required:

34470
31284
20022
13904

20
22
35
50

13.57
15.44
24.13
34.75

24
28
43
63

16.97
19.30
30.16
43.43

29
33
52
75

20.36
23.16
36.19
52.12

34
39
61
88

23.75
27.02
42.23
60.81

39
44
70
100

27.15
30.89
48.26
69.49

44
50
78
113

30.54
34.75
54.29
78.18

49
56
87
125

33.93
38.61
60.32
86.87

Plunger Plunger
Dia.
Area
mm
Sq. cm.

30T-2L
38
44
51
57

11.4010
15.5180
20.2684
25.6522

30T-2H
24
25
32
38

11

13

16

18

20

22

*For Operations below 200 RPM, auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Triplex Plunger Pump

50T-3

Rated input horsepower


"T" Triplex
Stroke length (in.)

This 3" stroke pump is


designed for a variety of
fluid transfer applications.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
50T-3

1-1/4 (31.8) FNP Threaded.

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

2 (50.8) FNP Threaded.

50T-3

39-1/2"

24-1/2"

14"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ............2 x 3 (50.8 x 76.2)
Rated BHP At 450 RPM (Kw) ...................................................................50 (37.5)
Rated Plunger Load, pounds (Kg).......................................................4,400 (2002)
Maximum Working Pressure: PSI (kPa) ........................................3,594 (24,727)
Crankshaft Extension: in. (mm) .............................................................2.5 (63.5)
Weight: - Lbs. (Kg)
Pump Only On Wood Shipping Skids.......................................................900 (405)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze Stuffing Boxes & Nuts
Bronze Stuffing Box Internals
Ceramic or Metal Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Chamber Cover
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

000X-0/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
(Sq. In.)

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

164
236
321
420

4.78
6.89
9.37
12.24

246
354
482
630

7.17
10.33
14.06
18.36

328
472
643
840

9.56
13.77
18.74
24.48

410
590
804
1050

11.95
17.21
23.43
30.60

492
708
964
1259

14.34
20.66
28.11
36.72

574
827
1125
1469

16.73
24.10
32.80
42.84

656
945
1286
1679

19.13
27.54
37.49
48.96

738
1063
1446
1889

21.52
30.98
42.17
55.08
50

50T-3
1 1/4
1 1/2
1 3/4
2

1.2272 1.6400 0.0478 3594


1.7672 2.3616 0.0689 2496
2.4053 3.2143 0.0937 1833
3.1416 4.1983 0.1224 1404
Brake Horsepower Required:

11

17

22

28

33

39

44

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min. Max.
Per Press.
RPM
kPa

100RPM
M3/D

L/Min.

150 RPM
M3/D

L/Min.

200 RPM
M3/D

250 RPM

L/Min.

M3/D

36.19
52.12
70.94
92.66
16.4

65
94
128
167

300 RPM

L/Min.

M3/D

45.24
65.15
88.68
115.82
20.9

78
113
153
200

GPM

350 RPM
M3/D

400 RPM

L/Min.

M3/D

63.34
91.21
124.15
162.15
29.0

104
150
204
267

450 RPM

L/Min.

M3/D

72.39
104.24
141.88
185.31
32.8

117
169
230
300

L/Min.

50T-3
32
38
44
51

7.9174 0.2607 0.1810


11.4010 0.3755 0.2606
15.5180 0.5110 0.3547
20.2684 0.6675 0.4633
Kilowatts Required:

24,780
17,209
12,638
9,680

26
38
51
67

18.10
26.06
35.47
46.33
8.2

39
56
77
100

27.15
39.09
53.21
69.49
12.7

52
75
102
133

54.29
78.18
106.41
138.99
24.6

91
131
179
234

81.44
117.27
159.62
208.48
37.3

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly J-60

60T-3 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 3" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Suction Connection Size

Dimensions
Pump Type

Length

Width

2 (50.8) API-2000# RTJ

3 (76.2) ANSI-150 F.F.

60T-3L Flanged

45-3/8"

35-3/8" 13-3/8"

60T-3M

1-1/2 (38.1) API-5000# RTJ

2-1/2 (63.5) ANSI-150 F.F.

60T-3M Flanged

45-3/8"

35-3/8" 13-3/8"

60T-3H

1-1/4 (31.75) ANSI-2500 RTJ

2-1/2 (63.5) ANSI-300 F.F.

60T-3H Flanged

45-3/8"

35-3/8" 13-3/8"

Field Connections in. (mm)


Pump Model
Discharge Connection Size
60T-3L

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm)............3- x 3 (76.2 x 76.2)
Rated BHP At 500 RPM (Kw)..................................................................60 (44.74)
Rated Plunger Load, pounds (Kg)...................................................4,750 (2,154.5)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure .........................................................1,500 (10,341)
"M" Model Discharge Pressure ........................................................3,200 (22,061)
"H" Model Discharge Pressure.........................................................5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter ......................................................................................................3 (76.2)
Length (long side) ...............................................................................5 3/4 (146.1)
Length (short side) ............................................................................5 9/16 (141.3)
Keyway (Width x Depth).........................................................3/4 x 3/8 (19.1 x 9.5)

Height

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter .............................................................2-1/4 (57.2)
Length.................................................................3-7/8 (98.4)
Keyway (Width x Depth) ................5/8 x 5/16 (15.88 x 7.94)
Direct Drive: Diameter .............................................................2-1/4 (57.2)
Length.................................................................3-7/8 (98.4)
Keyway (Width x Depth) ................5/8 x 5/16 (15.88 x 7.94)
Oil Capacity: Gallons (L)
Crankcase .....................................................................................................2 (7.6)
Gear Unit (Varies with Ratio).........................................................................1 (3.8)
Weight:
Pump Only On Wood Shipping Skids - Lbs. (Kg) ..............................1,145 (519.3)
Gear Unit - Lbs. (Kg) ...........................................................................315 (142.88)

Bolt On Style Gear Reducers


2.34:1 Ratio
2.77:1 Ratio
3.50:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

60T-3/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

500 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

3.1416
3.9761
4.9088
5.9396
7.0686

4.1983
5.3135
6.5599
7.9374
9.4462

0.1224
0.1549
0.1913
0.2314
0.2754

1500
1195
968
800
672

840
1063
1312
1587
1889

24.48
30.98
38.25
46.28
55.08

1050
1328
1640
1984
2362

30.60
38.73
47.81
57.85
68.85

1259
1594
1968
2381
2834

36.72
46.47
57.38
69.42
82.62

1469
1860
2296
2778
3306

42.84
54.22
66.94
80.99
96.39

1679
2125
2624
3175
3778

48.96
61.97
76.50
92.57
110.16

1889
2391
2952
3572
4251

55.08
69.71
86.06
104.14
123.93

2099
2657
3280
3969
4723

61.20
77.46
95.63
115.71
137.70

1.7672
2.4053
3.1416

2.3616
3.2143
4.1983

0.0689
0.0937
0.1224

2689
1976
1513

472
643
840

13.77
18.74
24.48

590
804
1050

17.21
23.43
30.60

708
964
1259

20.66
28.11
36.72

827
1125
1469

24.10
32.80
42.84

945
1286
1679

27.54
37.49
48.96

1063
1446
1889

30.98
42.17
55.08

1181
1607
2099

34.43
46.86
61.20

0.7854 1.0496 0.0306 5000


1.2272 1.6400 0.0478 3872
Brake Horsepower Required:

210
328

6.12
9.56

262
410

7.65
11.95

315
492

9.18
14.34

367
574

10.71
16.73

420
656

12.24
19.13

472
738

13.77
21.52

525
820

15.30
23.91

60T-3L
2
2 1/4
2 1/2
2 3/4
3

60T-3M
1 1/2
1 3/4
2

60T-3H
1
1 1/4

24

30

36

42

48

54

60

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

500 RPM

Metric Units
M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

M3/D

L/Min.

0.6675
0.8448
1.0430
1.2620
1.5019

0.4633
0.5863
0.7239
0.8759
1.0424

10341
8239
6674
5516
4635

133
169
209
252
300

92.66
117.27
144.78
175.18
208.48

167
211
261
315
375

115.82
146.59
180.97
218.97
260.60

200
253
313
379
451

138.99
175.90
217.16
262.77
312.72

234
296
365
442
526

162.15
205.22
253.36
306.56
364.84

267
338
417
505
601

185.31
234.54
289.55
350.36
416.96

300
380
469
568
676

208.48
263.85
325.75
394.15
469.08

334
422
521
631
751

231.64
293.17
361.94
437.95
521.19

11.4010 0.3755
15.5180 0.5110
20.2684 0.6675

0.2606
0.3547
0.4633

18539
13620
10428

75
102
133

52.12
70.94
92.66

94
128
167

65.15
88.68
115.82

113
153
200

78.18
106.41
138.99

131
179
234

91.21
124.15
162.15

150
204
267

104.24
141.88
185.31

169
230
300

117.27
159.62
208.48

188
256
334

130.30
177.35
231.64

5.0671 0.1669 0.1158


7.9174 0.2607 0.1810
Kilowatts Required:

34470
26696

33
52

23.16
36.19

42
65

28.96
45.24

50
78

34.75
54.29

58
91

40.54
63.34

67
104

46.33
72.39

75
117

52.12
81.44

83
130

57.91
90.49

Plunger Plunger
Dia.
Area
mm Sq. cm.

60T-3L
51
57
64
70
76

20.2684
25.6522
31.6694
38.3200
45.6040

60T-3M
39
45
51

60T-3H
26
32

18

22

27

31

36

40

45

*For operations below 200 RPM, an auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general
information only. Applications suggested for the materials and
other information are described only to help readers make
their own evaluations and decisions, and are neither
guarantees nor are they to be construed as express or
implied warranties of suitability for these or other applications.
National Oilwell makes no warranty, either express or implied,
beyond that stipulated in National Oilwells Standard Terms
and Conditions of Sale which are available upon request.

80T-3 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges "L" Low,
"M" Medium, "H" High

This 3" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.

Performance Data >

Field Connections in. (mm)


Pump Model
Discharge Connection Size
80T-3L Flanged

2 (50.8) API-2000# RTJ

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

3 (76.2) ANSI-150 F.F.

80T-3L Flanged

46-3/8"

35-3/8"

13-3/8"

80T-3M

1-1/2 (38.1) API-5000# RTJ

2-1/2 (63.5) ANSI-150 F.F.

80T-3M Flanged

46-3/8"

35-3/8"

13-3/8"

80T-3H

1-1/4 (31.75) ANSI-2500 RTJ

2-1/2 (63.5) ANSI-300 F.F.

80T-3H Flanged

46-3/8"

35-3/8"

13-3/8"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ..3-3/8 x 3 (85.725 x 76.2)
Rated BHP At 500 RPM (Kw) .................................................................80 (59.65)
Rated Plunger Load, pounds (Kg).......................................................6,336 (2874)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure ..........................................................2,016 (13,901)
M Model Discharge Pressure.........................................................3,584 (29,408)
H Model Discharge Pressure .........................................................5,161 (35,587)
Crankshaft Extension: in. (mm)
Diameter .....................................................................................................3 (76.2)
Length (long side) ...............................................................................5 3/4 (146.1)
Length (short side) ............................................................................5 9/16 (141.3)
Keyway (Width x Depth) .........................................................3/4 x 3/8 (19.1 x 9.5)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ............................................................2-1/4 (57.2)
Length.................................................................3-7/8 (98.4)
Keyway (Width x Depth) ...............5/8 x 5/16 (15.88 x 7.94)
Direct Drive: Diameter .............................................................2-1/4 (57.2)
Length.................................................................3-7/8 (98.4)
Keyway (Width x Depth) ................5/8 x 5/16 (15.88 x 7.94)
Oil Capacity: Gallons (L)
Crankcase ....................................................................................................2 (7.6)
Gear Unit (Varies with Ratio).........................................................................1 (3.8)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) .................1,195 (542.0)
Gear Unit - Lbs. (Kg) ...........................................................................315 (142.88)

Bolt On Style Gear Reducers


2.34:1 Ratio
2.77:1 Ratio
3.50:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

80T-3/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

500 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

3.1416 4.1983
3.9761 5.3135
4.9088 6.5599
5.9396 7.9374
7.0686 9.4462
8.2958 11.0862

0.1224
0.1549
0.1913
0.2314
0.2754
0.3232

2016
1593
1290
1066
896
763

840
1063
1312
1587
1889
2217

24.48
30.98
38.25
46.28
55.08
64.64

1050
1328
1640
1984
2362
2772

30.60
38.73
47.81
57.85
68.85
80.80

1259
1594
1968
2381
2834
3326

36.72
46.47
57.38
69.42
82.62
96.96

1469
1860
2296
2778
3306
3880

42.84
54.22
66.94
80.99
96.39
113.12

1679
2125
2624
3175
3778
4434

48.96
61.97
76.50
92.57
110.16
129.29

1889
2391
2952
3572
4251
4989

55.08
69.71
86.06
104.14
123.93
145.45

2099
2657
3280
3969
4723
5543

61.20
77.46
95.63
115.71
137.70
161.61

1.7672
2.4053
3.1416

0.0689
0.0937
0.1224

3584
2633
2016

472
643
840

13.77
18.74
24.48

590
804
1050

17.21
23.43
30.60

708
964
1259

20.66
28.11
36.72

827
1125
1469

24.10
32.80
42.84

945
1286
1679

27.54
37.49
48.96

1063
1446
1889

30.98
42.17
55.08

1181
1607
2099

34.43
46.86
61.20

1.2272 1.6400 0.0478 5161


Brake Horsepower Required

328

9.56

410

11.95

492

14.34

574

16.73

656

19.13

738

21.52

820

80T-3L
2
2 1/4
2 1/2
2 3/4
3
**3 1/4

80T-3M
1 1/2
1 3/4
2

2.3616
3.2143
4.1983

80T-3H
1 1/4

23.91

32

40

48

56

64

72

80

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

500 RPM

Metric Units
M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

M3/D

L/Min.

0.6675
0.8448
1.0430
1.2620
1.5019
1.7624

0.4633
0.5863
0.7239
0.8759
1.0424
1.2233

13901
10984
8895
7350
6178
5261

133
169
209
252
300
352

92.66
117.27
144.78
175.18
208.48
244.51

167
211
261
315
375
441

115.82
146.59
180.97
218.97
260.60
305.83

200
253
313
379
451
529

138.99
175.90
217.16
262.77
312.72
367.15

234
296
365
442
526
617

162.15
205.22
253.36
306.56
364.84
428.08

267
338
417
505
601
705

185.31
234.54
289.55
350.36
416.96
489.40

300
380
469
568
676
793

208.48
263.85
325.75
394.15
469.08
550.72

334
422
521
631
751
881

231.64
293.17
361.94
437.95
521.19
611.66

11.4010 0.3755
15.5180 0.5110
20.2684 0.6675

0.2606
0.3547
0.4633

24713
18155
13901

75
102
133

52.12
70.94
92.66

94
128
167

65.15
88.68
115.82

113
153
200

78.18
106.41
138.99

131
179
234

91.21
124.15
162.15

150
204
267

104.24
141.88
185.31

169
230
300

117.27
159.62
208.48

188
256
334

130.30
177.35
231.64

7.9174 0.2607 0.1810


Kilowatts Required

35587

52

36.19

65

45.24

78

54.29

91

63.34

104

72.39

117

81.44

130

Plunger Plunger
Dia.
Area
mm
Sq. cm.

80T-3L
51
57
64
70
76
** 83

20.2684
25.6522
31.6694
38.3200
45.6040
53.524

80T-3M
38
44
51

80T-3H
32

24

30

36

42

48

54

90.49
60

* For operations below 200 RPM, an auxiliary lubrication system is required.


** Require Spherical Valves
Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly C-523

84Q-3

Quintuplex Plunger Pump

Rated input horsepower


"Q" Quintuplex
Stroke length (in.)

This 3" stroke pump is


designed for a variety of
fluid transfer applications.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
84Q-3

4 (101.61) NPT Threaded

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

6 (152.4) NPT Threaded

84Q-3

40-3/4"

43-3/4"

20"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) .............2-1/2 x 3 (64 x 76)
Rated BHP At 500 RPM (Kw) ......................................................................84 (63)
Rated Plunger Load (Kg) ................................................................4,000 (1,814.4)
Maximum Working Pressure: PSI (kPa) ........................................2,260 (15,582)
Crankshaft Extension: in. (mm)
Diameter ..................................................................................................2.995 (76)
Length ....................................................................................................4-7/8 (124)
Keyway (Width x Depth) .............................................................3/4 x 3/8 (19 x 10)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ...............................................................1.870 (47)
Length..................................................................4-7/8 (124)
Keyway (Width x Depth) .........................1/2 x 1/4 (13 x 16)
Direct Drive: Diameter ...............................................................1.870 (47)
Length..................................................................4-7/8 (124)
Keyway (Width x Depth) .........................1/2 x 1/4 (13 x 16)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
3.54:1 Ratio
3.95:1 Ratio
4.45:1 Ratio

Oil Capacity: Gallons (L)


Crankcase ................................................................................................3-1/2 (13)
Gear Unit (Vertically Mounted) .........................................................................1 (4)
(Horizontally Mounted) ...............................................................................1-1/2 (6)

Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ....................1,655 (751)
Gear Unit - Lbs. (Kg) ..................................................................................175 (79)

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access To Bearings
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes
Interchangeable Valves
84Q-3/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max. 100 RPM


150 RPM
Press.
PSI BPD GPM BPD GPM

200 RPM

250 RPM

300 RPM

BPD GPM

BPD

GPM

BPD

547
787
1071
1399
1771
2187

683
984
1339
1749
2214
2733

19.92
28.69
39.05
51.00
64.55
79.69
51

820
1181
1607
2099
2657
3280

350 RPM

GPM BPD GPM

400 RPM

450 RPM

500 RPM

BPD GPM BPD GPM

BPD GPM

1093
1574
2143
2799
3542
4373

1367
1968
2679
3499
4428
5467

84Q-3
1 1/4
1 1/2
1 3/4
2
2 1/4
2 1/2

1.2272 2.7333 0.0797 2260


1.7672 3.9359 0.1148 2260
2.4053 5.3572 0.1562 1660
3.1416 6.9972 0.2040 1275
3.9761 8.8558 0.2582 1005
4.9088 10.9331 0.3188 815
Brake Horsepower Required17

273 7.97
394 11.48
536 15.62
700 20.40
886 25.82
1093 31.88
25

410 11.95
590 17.21
804 23.43
1050 30.60
1328 38.73
1640 47.81
34

15.94
22.95
31.24
40.80
51.64
63.75
42

23.91
34.43
46.86
61.20
77.46
95.63
59

957
1378
1875
2449
3100
3827

27.89
40.16
54.67
71.40
90.37
111.56
67

31.87
45.90
62.47
81.60
103.28
127.50
76

1230 35.86
1771 51.64
2411 70.28
3149 91.80
3985 116.18
4920 143.44
84

39.84
57.37
78.09
102.00
129.69
159.37

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

M3/D
Per
RPM

L/Min. Max. 100 RPM


150 RPM
200 RPM
250 RPM
300 RPM
Per Press.
RPM kPa M3/D L/Min. M3/D L/Min. M3/D L/Min. M3/D L/Min. M3/D GPM

350 RPM

400 RPM

450 RPM

500 RPM

M3/D L/Min. M3/D L/Min. M3/D L/Min. M3/D L/Min.

84Q-3
32
38
44
51
57
64

7.9174
11.4010
15.518
20.2684
25.6522
31.6694

0.4346 0.3016 15582 43 30.16


0.6258 0.4343 15582 63 43.43
0.8504 0.5912 11445 85 59.12
1.1125 0.7721 8790 111 77.21
1.4080 0.9772 6929 141 97.72
1.7383 1.2065 5619 174 120.65
Kilowatts Required
13

65
94
128
167
211
261

45.24
65.15
88.68
115.82
146.59
180.97
19

87 60.32
125 86.87
170 118.24
222 154.43
282 195.45
348 241.29
25

109
156
213
278
352
435

75.40
108.58
147.80
193.04
244.31
301.62
31

130
188
255
334
422
521

90.49
130.30
177.36
231.64
293.17
361.94
38

152 105.57
219 152.02
298 206.9
389 270.25
493 342.03
608 422.26
44

174 120.65
250 173.73
340 236.48
445 308.86
563 390.90
695 482.59
50

195 135.60
281 195.60
383 266.04
500 347.40
633 439.80
782 543.00
56

217
313
425
556
704
869

150.60
217.20
295.60
386.40
488.40
603.00
63

* For operations below 50 RPM, an auxiliary lubrication system is required.


Volume is based on 100 % volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly J-100

100T-4 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 4" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
100T-4L

2-1/2 (63.5) API-2000# RTJ

Dimensions
Pump Type Length

Suction Connection Size


5 (127) ANSI-150 F.F.

100T-4L

Width

Height

57-3/8"

48-7/8"

19-5/8"

100T-4M

1-1/2 (38.1) API-5000# RTJ

3 (76.2) ANSI-150 F.F.

100T-4M

55-3/8"

48-7/8"

19-5/8"

100T-4H

1-1/2 (38.1) ANSI-2500 RTJ

3 (76.2) ANSI-300 F.F.

100T-4H

55-3/8"

48-7/8"

19-5/8"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) .....3-3/8 x 4 (85.7 x 101.6)
Rated BHP At 450 RPM (Kw) ....................................................................100 (75)
Rated Plunger Load, pounds (Kg)......................................................6,595 (2,291)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure ........................................................ 1,660 (11,444)
"M" Model Discharge Pressure ....................................................... 3,182 (21,939)
"H" Model Discharge Pressure.........................................................5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter..............................................................................................3-3/4 (95.25)
Length ........................................................................8-5/16, 8-1/2 (211.38, 215.9)
Keyway (Width x Depth) ...................................................7/8 x 7/16 (22.2 X 11.1)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ...........................................................2-3/8 (60.33)
Length.............................................................6-1/2 (165.10)
Keyway (Width x Depth) ................5/8 x 5/16 (15.88 x 7.94)
Direct Drive: Diameter ...........................................................2-3/8 (60.33)
Length.............................................................6-1/2 (165.10)
Keyway (Width x Depth) ................5/8 x 5/16 (15.88 x 7.94)
Oil Capacity: Gallons (L)
Crankcase ................................................................................................5.5 (20.8)
Gear Unit .....................................................................................................3 (11.4)
Weight:
Pump Only On Wood Shipping Skids - Lbs. (Kg).............................2,300 (1043.3)
Gear Unit - Lbs. (Kg) .............................................................................500 (226.8)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
2.60:1 Ratio
3.15:1 Ratio
3.42:1 Ratio
3.89:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access To Bearings
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes
Interchangeable Valves

100T-4/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

150 RPM*

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

3.9761 7.0847 0.2066


4.9088 8.7465 0.2550
5.9396 10.5833 0.3086
7.0686 12.5950 0.3672
8.2958 14.7816 0.4310

1660
1345
1111
934
796

1063
1312
1587
1889
2217

30.98
38.25
46.28
55.08
64.64

1417
1749
2117
2519
2956

41.31
51.00
61.71
73.44
86.19

1771
2187
2646
3149
3695

51.65
63.75
77.14
91.80
107.74

2125
2624
3175
3778
4434

61.97
76.50
92.57
110.16
129.29

2480
3061
3704
4408
5174

72.29
89.25
107.99
128.52
150.83

2834
3499
4233
5038
5913

82.62
102.00
123.42
146.88
172.38

3188
3936
4762
5668
6652

92.95
114.75
138.85
165.24
193.93

2.4053
3.1416

2744
2101

643
840

18.74
24.48

857
1120

24.99
32.64

1071
1399

31.24
40.80

1286
1679

37.49
48.96

1500
1959

43.73
57.12

1714
2239

49.98
65.28

1929
2519

56.23
73.44

1.2272 2.1866 0.0638 5000


1.7672 3.1487 0.0918 3735
2.4053 4.2858 0.1250 2744
Brake Horsepower Required:

328
472
643

9.56
13.77
18.74

437
630
857

12.75
18.36
24.99

547
787
1071

15.94
22.95
31.24

656
945
1286

19.13
27.54
37.49

765
1102
1500

22.31
32.13
43.73

875
1259
1714

25.50
36.72
49.98

984
1417
1929

28.69
41.31
56.23
100

100T-4L
2 1/4
2 1/2
2 3/4
3
3 1/4

100T-4M
1 3/4
2

4.2858
5.5978

0.1250
0.1632

100T-4H
1 1/4
1 1/2
1 3/4

33

44

56

67

78

89

150 RPM*

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

Metric Units
M3/D
Per
RPM

L/Min.
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

1.1264
1.3906
1.6824
2.0022
2.3498

0.7818
0.9652
1.1679
1.3898
1.6311

11444
9269
7661
6437
5485

169
209
252
300
352

117.27
144.78
175.19
208.47
244.67

225
278
336
400
470

156.36
193.04
233.58
277.96
326.22

282
348
421
501
587

195.45
241.29
291.98
347.45
407.78

338
417
505
601
705

234.54
289.55
350.37
416.94
489.33

394
487
589
701
822

273.63
337.81
408.77
486.43
570.89

451
556
673
801
940

312.72
386.07
467.16
555.92
652.44

507
626
757
901
1057

351.81
434.33
525.56
625.41
734.00

15.5180 0.6814
20.2684 0.8900

0.4729
0.6177

18917
14483

102
133

70.94
92.66

136
178

94.59
123.54

170
222

118.23
154.43

204
267

141.88
185.31

238
311

165.53
216.20

273
356

189.17
247.08

307
400

212.82
277.97

7.9174 0.3477 0.2413


11.4010 0.5006 0.3475
15.5180 0.6814 0.4729
Kilowatts Required:

34470
25748
18917

52
75
102

36.19
52.12
70.94

70
100
136

48.26
69.49
94.59

87
125
170

60.32
86.87
118.23

104
150
204

72.39
104.24
141.88

122
175
238

84.45
121.61
165.53

139
200
273

96.52
138.99
189.17

156
225
307

108.58
156.36
212.82
75

Plunger Plunger
Dia.
Area
mm
Sq. cm.

450 RPM

100T-4L
57
64
70
76
83

25.6522
31.6694
38.3221
45.6065
53.5243

100T-4M
44
51

100T-4H
32
38
44

25

33

41

50

58

66

*For operations below 200 RPM, an auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly A-344-H, A-334-H, A-324-H

125T-4 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 4" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.

Field Connections in. (mm)


Pump Model Discharge Connection Size

Performance Data >

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

3 (76.2) Sch. 160, V-Bevel

6 (152.4) Sch. 40, V-Bevel

125T-4L

56"

43-3/4"

27-7/8"

125T-4M

3 (76.2) Sch. 160, V-Bevel

4 (101.6) Sch. 40, V-Bevel

125T-4M

52-1/8"

43-3/4"

22-1/4"

125T-4H

2 (50.8) Sch. 160, V-Bevel

3 (76.2) Sch. 80, V-Bevel

125T-4H

52-1/8"

43-3/4"

21-1/4"

125T-4L

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm).........4 x 4 (101.6 x 101.6)
Rated BHP At 450 RPM (Kw).....................................................................125 (93)
Rated Plunger Load, pounds (Kg)......................................................8,250 (3,472)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure ........................................................ 1,500 (10,342)
"M" Model Discharge Pressure ....................................................... 3,180 (21,925)
"H" Model Discharge Pressure........................................................ 5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter..............................................................................................3-3/4 (95.25)
Length ....................................................................................................7 1/2 (191)
Keyway (Width x Depth) ....................................................7/8 x 7/16 (22.2 X 11.1)
Pinion Shaft Extension:
Diameter...................................................................................................2-7/8 (73)
Length ....................................................................................................6-3/4 (171)
Keyway (Width x Depth)..............................................................3/4 x 1/4 (19 x 6)
Oil Capacity: Gallons (L)
Crankcase & Gearcase ................................................................................10 (38)
Weight:
Pump Only On Wood Shipping Skids - Lbs. (Kg) .................................1,747 (792)
Gear Unit - Lbs. (Kg) ................................................................................575 (261)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
2.596:1 Ratio
3.109:1 Ratio
3.947:1 Ratio
6.192:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features:

Horizontal Design
Large Power End Access Covers And Doors
Easy Bearing Access
Separate Crosshead/Plunger Shank Construction
Open Frame Cradle
Removable Stuffing Boxes

125T-4/6.99

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)

< Return To Specs

English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

8.7465
10.5833
12.5950
14.7816
17.1431
19.6796
22.3910

0.2550
0.3086
0.3672
0.4310
0.4998
0.5738
0.6528

1500
1389
1167
994
857
747
657

875
1058
1259
1478
1714
1968
2239

25.50
30.86
36.72
43.10
49.98
57.38
65.28

1312
1587
1889
2217
2571
2952
3359

38.25
46.28
55.08
64.64
74.97
86.06
97.92

1749
2117
2519
2956
3429
3936
4478

51.00
61.71
73.44
86.19
99.96
114.75
130.56

2187
2646
3149
3695
4286
4920
5598

63.75
77.14
91.80
107.74
124.95
143.44
163.20

2624
3175
3778
4434
5143
5904
6717

76.50
92.57
110.16
129.29
149.94
172.13
195.84

3061
3704
4408
5174
6000
6888
7837

89.25
107.99
128.52
150.83
174.93
200.81
228.48

3499
4233
5038
5913
6857
7872
8956

102.00
123.42
146.88
172.38
199.92
229.50
261.12

3936
4762
5668
6652
7714
8856
10076

114.75
138.85
165.24
193.93
224.91
258.19
293.76

2.4053 4.2858 0.1250


3.1416 5.5978 0.1632
3.9761 7.0847 0.2066
4.9088 8.7465 0.2550
5.9396 10.5833 0.3086
7.0686 12.5950 0.3672

3180
2626
2075
1681
1389
1167

429
560
708
875
1058
1259

12.50
16.32
20.66
25.50
30.86
36.72

643
840
1063
1312
1587
1889

18.74
24.48
30.98
38.25
46.28
55.08

857
1120
1417
1749
2117
2519

24.99
32.64
41.31
51.00
61.71
73.44

1071
1399
1771
2187
2646
3149

31.24
40.80
51.64
63.75
77.14
91.80

1286
1679
2125
2624
3175
3778

37.49
48.96
61.97
76.50
92.57
110.16

1500
1959
2480
3061
3704
4408

43.73
57.12
72.29
89.25
107.99
128.52

1714
2239
2834
3499
4233
4721**

49.98
65.28
82.62
102.00
123.42
137.63**

1929 56.2
2519 73.44
3188 92.95
3936 114.75
4762 138.85
n/a
n/a

1.2272 2.1866 0.0638 5000


1.7672 3.1487 0.0918 4669
2.4053 4.2858 0.1250 3430
3.1416 5.5978 0.1632 2626
3.9761 7.0847 0.2066 2075
Brake Horsepower Required

219
315
429
560
708

6.38
9.18
12.50
16.32
20.66

328
472
643
840
1063

9.56
13.77
18.74
24.48
30.98

437
630
857
1120
1417

12.75
18.36
24.99
32.64
41.31

547
787
1071
1399
1771

15.94
22.95
31.24
40.80
51.64

656
945
1286
1679
2125

19.13
27.54
37.49
48.96
61.97

765
1102
1500
1959
2480

22.31
32.13
43.73
57.12
72.29

875
1259
1714
2239
2834

25.50
36.72
49.98
65.28
82.62

125T-4L
2 1/2
2 3/4
3
3 1/4
3 1/2
3 3/4
4

4.9088
5.9396
7.0686
8.2958
9.6212
11.0447
12.5664

125T-4M
1 3/4
2
2 1/4
2 1/2
2 3/4
3

125T-4H
1 1/4
1 1/2
1 3/4
2
2 1/4

28

42

56

69

83

97

984
1417
1929
2519
3188

111

28.69
41.31
56.23
73.44
92.95
125

Metric Units
M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

31.6694
38.3200
45.6040
53.5213
62.0721
71.2562
81.0737

1.3906
1.6826
2.0025
2.3501
2.7256
3.1289
3.5600

0.9652 10342
1.1679 9577
1.3899 8046
1.6311 6853
1.8917 5909
2.1716 5150
2.4708 4530

15.5180
20.2684
25.6522
31.6694
38.3200
45.6040

0.6814
0.8900
1.1264
1.3906
1.6826
2.0025

0.4729
0.6177
0.7818
0.9652
1.1679
1.3899

7.9174 0.3477 0.2413


11.4010 0.5006 0.3475
15.5180 0.6814 0.4729
20.2684 0.8900 0.6177
25.6522 1.1264 0.7818
Kilowatts Required

Plunger Plunger
Dia.
Area
mm Sq. cm.

100 RPM*

150 RPM

L/Min.

M3/D

139
168
200
235
273
313
356

96.52
116.79
138.99
163.11
189.17
217.16
247.08

21925
18106
14307
11590
9577
8046

68
89
113
139
168
200

34474
32192
23649
18106
14307

35
50
68
89
113

200 RPM

250 RPM

300 RPM

L/Min.

L/Min.

M3/D

209
252
300
353
409
469
534

144.78
175.18
208.48
244.67
283.76
325.75
370.63

278
337
400
470
545
626
712

193.04
233.57
277.97
326.23
378.35
434.33
494.17

348
421
501
588
681
782
890

241.29 417
291.97 505
347.46 601
407.79 705
472.94 818
542.91 939
617.71 1068

289.55 487
350.36 589
416.96 701
489.34 823
567.52 954
651.49 1095
741.25 1246

47.29
61.77
78.18
96.52
116.79
138.99

102
133
169
209
252
300

70.94
92.66
117.27
144.78
175.18
208.48

136
178
225
278
337
400

94.59
123.54
156.36
193.04
233.57
277.97

170
222
282
348
421
501

118.23
154.43
195.45
241.29
291.97
347.46

204
267
338
417
505
601

141.88
185.31
234.54
289.55
350.36
416.96

238
311
394
487
589
701

24.13
34.75
47.29
61.77
78.18

52
75
102
133
169

36.19
52.12
70.94
92.66
117.27

70
100
136
178
225

48.26
69.49
94.59
123.54
156.36

87
125
170
222
282

60.32
86.87
118.23
154.43
195.45

104
150
204
267
338

72.39
104.24
141.88
185.31
234.54

122
175
238
311
394

L/Min.

M3/D

350 RPM

M3/D

L/Min.

M3/D

400 RPM

450 RPM

GPM

M3/D

L/Min.

337.81 556
408.75 673
486.45 801
570.90 940
662.11 1090
760.08 1252
864.80 1424

386.07
467.14
555.94
652.46
756.70
868.66
988.34

626
757
901
1058
1227
1408
1602

434.33
525.54
625.43
734.02
851.28
977.24
1111.88

165.53 273
216.20 356
273.63 451
337.81 556
408.75 673
486.45 750**

189.17
247.08
312.72
386.07
467.14
520.98**

307
400
507
626
757
n/a

212.82
277.97
351.81
434.33
525.54
n/a

96.52
138.99
189.17
247.08
312.72
83

156
225
307
400
507

108.58
156.36
212.82
277.97
351.81
93

L/Min.

M3/D

125T-4L
64
70
76
83
89
95
102

125T-4M
44
51
57
64
70
76

125T-4H
32
38
44
51
57

21

31

41

52

62

84.45
121.61
165.53
216.20
273.63
72

139
200
273
356
451

*For operations below 50 RPM and for reverse rotation, consult manufacturer for lubrication recommendations. **Limited to 375 RPM to maintain low velocity through valve areas.
Displacement calculated at this speed. Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general
information only. Applications suggested for the materials and
other information are described only to help readers make
their own evaluations and decisions, and are neither
guarantees nor are they to be construed as express or
implied warranties of suitability for these or other applications.
National Oilwell makes no warranty, either express or implied,
beyond that stipulated in National Oilwells Standard Terms
and Conditions of Sale which are available upon request.

130T-4_

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 4" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
130T-4L

2-1/2 (63.5) API-2000# RTJ

Dimensions
Suction Connection Size

Pump Type

5 (127) ANSI-150 F.F.

130T-4L

Length

Width

Height

58-3/8"

48-7/8"

19-5/8"

130T-4M

1-1/2 (38.1) API-5000# RTJ

3 (76.2) ANSI-150 F.F.

130T-4M

56-3/8"

48-7/8"

19-5/8"

103T-4H

1-1/2 (38.1) ANSI-2500 RTJ

3 (76.2) ANSI-300 F.F.

130T-4H

56-3/8"

48-7/8"

19-5/8"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) .....3-5/8 x 4 (92.1 x 101.6)
Rated BHP At 450 RPM (Kw) ....................................................................130 (97)
Rated Plunger Load, pounds (Kg).......................................................8,590 (3899)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure ......................................................... 1,750 (12,070)
M Model Discharge Pressure........................................................ 3,111 (21,458)
H Model Discharge Pressure .........................................................5,000 (34,470)
Crankshaft Extension: in. (mm)
Diameter..............................................................................................3-3/4 (95.25)
Length .............................................................................................8 5/16 (211.38)
Keyway (Width x Depth) ....................................................7/8 x 7/16 (22.2 X 11.1)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ...........................................................2-3/8 (60.33)
Length.............................................................6-1/2 (165.10)
Keyway (Width x Depth) ...............5/8 x 5/16 (15.88 x 7.94)
Direct Drive: Diameter ...........................................................2-3/8 (60.33)
Length.............................................................6-1/2 (165.10)
Keyway (Width x Depth) ................5/8 x 5/16 (15.88 x 7.94)
Oil Capacity: Gallons (L)
Crankcase ................................................................................................5.5 (20.8)
Gear Unit (Varies with Ratio).......................................................................3 (11.4)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ...............2,360 (1070.5)
Gear Unit - Lbs. (Kg) .............................................................................500 (226.8)

Bolt On Style Gear Reducers


2.60:1 Ratio
3.15:1 Ratio
3.42:1 Ratio
3.89:1 Ratio
4.27:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes
Interchangeable Valves

130T-4/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger
Dia.
In.

Plunger
Area
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

4.9088
5.9396
7.0686
8.2958
9.6212

8.7465
10.5833
12.5950
14.7816
17.1431

0.2550
0.3086
0.3672
0.4310
0.4998

1750
1446
1215
1036
893

1749
2117
2519
2956
3429

51.00
61.71
73.44
86.19
99.96

2187
2646
3149
3695
4286

63.75
77.14
91.80
107.74
124.95

2624
3175
3778
4434
5143

76.50
92.57
110.16
129.29
149.94

3061
3704
4408
5174
6000

89.25
107.99
128.52
150.83
174.93

3499
4233
5038
5913
6857

102.00
123.42
146.88
172.38
199.92

3936
4762
5668
6652
7714

114.75
138.85
165.24
193.93
224.91

3.1416
3.9761

5.5978
7.0847

0.1632
0.2066

2735
2161

1120
1417

32.64
41.31

1399
1771

40.80
51.64

1679
2125

48.96
61.97

1959
2480

57.12
72.29

2239
2834

65.28
82.62

2519
3188

73.44
92.95

1.7672 3.1487 0.0918


4862
2.4053 4.2858 0.1250
3572
Brake Horsepower Required:

630
857

18.36
24.99

787
1071

22.95
31.24

945
1286

27.54
37.49

1102
1500

32.13
43.73

1259
1714

36.72
49.98

1417
1929

41.31
56.23

130T-4L
2 1/2
2 3/4
3
3 1/4
3 1/2

130T-4M
2
2 1/4

130T-4H
1 1/2
1 3/4

58

72

87

101

116

130

200 RPM*

250 RPM

300 RPM

350 RPM

400 RPM

450 RPM

Metric Units
Plunger
Dia.
mm

Plunger
Area
Sq. cm.

M3/D
Per
RPM

Liters
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

M3/D

L/Min.

31.6694
38.3200
45.6040
53.5213
62.0721

1.3906
1.6826
2.0025
2.3501
2.7256

0.9652
1.1679
1.3899
1.6311
1.8917

12,066
9,970
8,377
7,143
6,157

278
337
400
470
545

193.04
233.57
277.97
326.23
378.35

348
421
501
588
681

241.29
291.97
347.46
407.79
472.94

417
505
601
705
818

289.55
350.36
416.96
489.34
567.52

487
589
701
823
954

337.81
408.75
486.45
570.90
662.11

556
673
801
940
1090

386.07
467.14
555.94
652.46
756.70

626
757
901
1058
1227

434.33
525.54
625.43
734.02
851.28

20.2684
25.6522

0.8900
1.1264

0.6177
0.7818

18,858
14,900

178
225

123.54
156.36

222
282

154.43
195.45

267
338

185.31
234.54

311
394

216.20
273.63

356
451

247.08
312.72

400
507

277.97
351.81

11.4010 0.5006 0.3475


15.5180 0.6814 0.4729
Kilowatts Required:

33,523
24,629

100
136

69.49
94.59

125
170

86.87
118.23

150
204

104.24
141.88

175
238

121.61
165.53

200
273

138.99
189.17

225
307

156.36
212.82

130T-4L
64
70
76
83
89

130T-4M
51
57

130T-4H
38
44

43

54

65

75

87

97

* For operations below 200 RPM, an auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly 336-P & 346-P

Triplex Plunger Pump

160TP-6 _

Rated input horsepower


"T" Triplex
"P" Internal Pinion
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium

This 6" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

160TP-6L

3 (76.2) ANSI 600 L.R.

6" (154.4) ANSI 600 F.F.

160TP-6L

73-1/4"

49-1/2"

33-3/4"

160TP-6M

2-1/2 (63.5) ANSI 1500 L.R.

4" (101.6) ANSI 600 F.F.

160TP-6M

73-1/4"

49-1/2"

33-1/4"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...4-1/4 x 6 (107.9 x 152.4)
Rated BHP At 320 RPM (Kw) ..................................................................160 (119)
Rated Plunger Load, pounds (Kg)....................................................10,000 (4,536)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure .............................................................1,420 (9791)
M Model Discharge Pressure.........................................................3,180 (21,925)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ..........................................................2.995 (76.07)
Length.............................................................7-1/4 (184.15)
Keyway (Width x Depth) .................3/4 x 1/4 (19.05 x 6.35)
Oil Capacity: Gallons (L)
Crankcase ....................................................................................................13 (49)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) .................4,725 (2,143)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Lubricating Oil Pump
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Internal Pinion Gear
4.440:1 Ratio (Standard)
1.588:1 Ratio (Optional)
2.487:1 Ratio (Optional)
5.476:1 Ratio (Optional)

1.529:1
1.776:1
3.121:1
7.130:1

Ratio
Ratio
Ratio
Ratio

(Optional)
(Optional)
(Optional)
(Optional)

Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Access Covers And Doors
Outside Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Cradle Frame
Removable Stuffing Boxes
Interchangeable Valves
160TP-6/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger
Dia.
In.

Plunger
Area
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM

200 RPM

250 RPM

300 RPM

320 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

7.0686
8.2958
9.6212
11.0447
12.5664
14.1863

18.8924
22.1724
25.7147
29.5194
33.5866
37.9161

0.5508
0.6464
0.7497
0.8606
0.9792
1.1054

1420
1200
1040
905
795
705

1889
2217
2571
2952
3359
3792

55.08
64.64
74.97
86.06
97.92
110.54

2834
3326
3857
4428
5038
5687

82.62
96.96
112.46
129.09
146.88
165.81

3778
4434
5143
5904
6717
7583

110.16
129.29
149.94
172.13
195.84
221.09

4723
5543
6429
7380
8397
9479

137.70
161.61
187.43
215.16
244.80
276.36

5668
6652
7714
8856
10076
11375

165.24
193.93
224.91
258.19
293.76
331.63

6046
7095
8229
9446
10748
12133

176.26
206.86
239.90
275.40
313.34
353.74

3180
2520
2040
1680
1420

840
1063
1312
1587
1889

24.48
30.98
38.25
46.28
55.08

1259
1594
1968
2381
2834

36.72
46.47
57.38
69.42
82.62

1679
2125
2624
3175
3778

48.96
61.97
76.50
92.57
110.16

2099
2657
3280
3969
4723

61.20
77.46
95.63
115.71
137.70

2519
3188
3936
4762
5668

73.44
92.95
114.75
138.85
165.24

2687
3401
4198
5080
6046

78.34
99.14
122.40
148.10
176.26

160TP-6L
3
3 1/4
3 1/2
3 3/4
4
4 1/4

160TP-6M
2
2 1/4
2 1/2
2 3/4
3

3.1416 8.3966 0.2448


3.9761 10.6270 0.3098
4.9088 13.1198 0.3825
5.9396 15.8749 0.4628
7.0686 18.8924 0.5508
Brake Horsepower Required:

50

75

100

125

150

160

100 RPM*

150 RPM

200 RPM

250 RPM

300 RPM

320 RPM

Metric Units
Plunger
Dia.
mm

Plunger
Area
Sq. cm.

M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

45.6040
53.5213
62.0721
71.2562
81.0737
91.5246

3.0037
3.5252
4.0884
4.6933
5.3399
6.0283

2.0848
2.4467
2.8376
3.2575
3.7063
4.1840

9791
8274
7171
6240
5481
4861

300
353
409
469
534
603

208.48
244.67
283.76
325.75
370.63
418.40

451
529
613
704
801
904

312.72
367.01
425.64
488.62
555.94
627.61

601
705
818
939
1068
1206

416.96
489.34
567.52
651.49
741.25
836.81

751
881
1022
1173
1335
1507

521.19
611.68
709.40
814.37
926.57
1046.01

901
1058
1227
1408
1602
1808

625.43
734.02
851.28
977.24
1111.88
1255.21

961
1128
1308
1502
1709
1929

667.13
782.95
908.04
1042.39
1186.01
1338.89

20.2684 1.3350 0.9266


25.6522 1.6896 1.1727
31.6694 2.0859 1.4478
38.3200 2.5239 1.7518
45.6040 3.0037 2.0848
Kilowatts Required:

21925
17374
14065
11583
9791

133
169
209
252
300

92.66
117.27
144.78
175.18
208.48

200
253
313
379
451

138.99
175.90
217.16
262.77
312.72

267
338
417
505
601

185.31
234.54
289.55
350.36
416.96

334
422
521
631
751

231.64
293.17
361.94
437.95
521.19

400
507
626
757
901

277.97
351.81
434.33
525.54
625.43

427
541
667
808
961

296.50
375.26
463.28
560.57
667.13

160TP-6L
76
83
89
95
102
108

160TP-6M
51
57
64
70
76

38

56

75

94

113

119

* For operation below 50 RPM an auxiliary lube system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly J-165

165T-5 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 5" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
165T-5L

3 (76.2) API-2000# RTJ

Dimensions
Suction Connection Size

Pump Type

6 (152.4) ANSI-150 F.F.

165T-5L

Length

Width

Height

65-1/2"

51-7/8"

22-7/8"

165T-5M

2 (50.8) API-5000# RTJ

4 (101.6) ANSI-150 F.F.

165T-5M

64-5/8"

51-7/8"

22-7/8"

165T-5H

2 (50.8) ANSI-2500 RTJ

3 (76.2) API-2000# RTJ

165T-5H

64-1/4"

51-7/8"

22-7/8"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...............4 x 5 (102 x 127)
Rated BHP At 400 RPM (Kw) ..................................................................165 (123)
Rated Plunger Load, pounds (Kg)...................................................9,800 (4,445.2)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure .........................................................1,650 (11,376)
"M" Model Discharge Pressure ........................................................3,120 (21,508)
"H" Model Discharge Pressure.........................................................5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter..............................................................................................4-1/8 (104.7)
Length ............................................................................5-7/8, 8-1/8 (231.5, 206.4)
Keyway (Width x Depth) ..........................................................1 x 1/2 (25.4 x 12.7)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ...................................................................3 (76.2)
Length...........................................................6-3/16 (157.16)
Keyway (Width x Depth) ..................3/4 x 3/8 (19.05 x 9.53)
Direct Drive: Diameter ...................................................................3 (76.2)
Length...........................................................6-3/16 (157.16)
Keyway (Width x Depth) ..................3/4 x 3/8 (19.05 x 9.53)
Oil Capacity: Gallons (L)
Crankcase ......................................................................................................8 (30)
Gear Unit (Varies with Ratio).....................................2-1/4 to 3-1/2 (8.52 to 13.25)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg)..................4,000 (1814)
Gear Unit - Lbs. (Kg) ................................................................................800 (363)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
2.8:1 Ratio
3.22:1 Ratio
4.38:1 Ratio
4.96:1 Ratio

3.46:1 Ratio

Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes
Interchangeable Valves

165T-5/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM*

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

13.2291
15.7437
18.4770
21.4289
24.5995
27.9888

0.3857
0.4590
0.5387
0.6248
0.7172
0.8160

1650
1387
1181
1019
887
780

1323
1574
1848
2143
2460
2799

38.57
45.90
53.87
62.48
71.72
81.60

1984
2362
2772
3214
3690
4198

57.85
68.85
80.80
93.71
107.58
122.40

2646
3149
3695
4286
4920
5598

77.14
91.80
107.74
124.95
143.44
163.20

3307
3936
4619
5357
6150
6997

96.42
114.75
134.67
156.19
179.30
204.00

3969
4723
5543
6429
7380
8397

115.71
137.70
161.61
187.43
215.16
244.80

4630
5510
6467
7500
8610
9796

134.99
160.65
188.54
218.66
251.02
285.60

5292
6297
7391
8572
9840
** 11195

154.28
183.60
215.48
249.90
286.88
** 326.40

3.1416 6.9972 0.2040


3.9761 8.8558 0.2582
4.9088 10.9331 0.3188
5.9396 13.2291 0.3857

3120
2465
2000
1650

700
886
1093
1323

20.40
25.82
31.88
38.57

1050
1328
1640
1984

30.60
38.73
47.81
57.85

1399
1771
2187
2646

40.80
51.64
63.75
77.14

1749
2214
2733
3307

51.00
64.55
79.69
96.42

2099
2657
3280
3969

61.20
77.46
95.63
115.71

2449
3100
3827
4630

71.40
90.37
111.56
134.99

2799
3542
4373
5292

81.60
103.28
127.50
154.28

1.7672 3.9359 0.1148 5000


2.4053 5.3572 0.1562 4075
3.1416 6.9972 0.2040 3120
Brake Horsepower Required:

394
536
700

11.48
15.62
20.40

590
804
1050

17.21
23.43
30.60

787
1071
1399

22.95
31.24
40.80

984
1339
1749

28.69
39.05
51.00

1181
1607
2099

34.43
46.86
61.20

1378
1875
2449

40.16
54.67
71.40

1574
2143
2799

45.90
62.48
81.60
165

165T-5L
2 3/4
3
3 1/4
3 1/2
3 3/4
4

5.9396
7.0686
8.2958
9.6212
11.0447
12.5664

165T-5M
2
2 1/4
2 1/2
2 3/4

165T-5H
1 1/2
1 3/4
2

Metric Units
Plunger Plunger
Dia.
Area
mm
Sq. cm.

41

62

83

103

124

144

100 RPM*

150 RPM*

200 RPM

250 RPM

300 RPM

350 RPM

M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

38.3200
45.6040
53.5213
62.0721
71.2562
81.0737

2.1033
2.5031
2.9377
3.4070
3.9111
4.4499

1.4598
1.7373
2.0389
2.3647
2.7146
3.0886

11376
9559
8145
7023
6118
5377

210
250
294
341
391
445

145.98
173.73
203.89
236.47
271.46
308.86

315
375
441
511
587
667

218.97
260.60
305.84
354.70
407.18
463.28

421
501
588
681
782
890

291.97
347.46
407.79
472.94
542.91
617.71

526
626
734
852
978
1112

364.96
434.33
509.73
591.17
678.64
772.14

631
751
881
1022
1173
1335

437.95
521.19
611.68
709.40
814.37
926.57

736
876
1028
1192
1369
1557

510.94
608.06
713.63
827.64
950.09
1081.00

20.2684
25.6522
31.6694
38.3200

1.1125
1.4080
1.7383
2.1033

0.7721
0.9772
1.2065
1.4598

21508
16994
13790
11376

111
141
174
210

77.21
97.72
120.65
145.98

167
211
261
315

115.82
146.59
180.97
218.97

222
282
348
421

154.43
195.45
241.29
291.97

278
352
435
526

193.04
244.31
301.62
364.96

334
422
521
631

231.64
293.17
361.94
437.95

389
493
608
736

270.25
342.03
422.26
510.94

445
563
695
841

308.86
390.90
482.59
583.93

11.4010 0.6258 0.4343


15.5180 0.8517 0.5912
20.2684 1.1125 0.7721
Kilowatts Required:

34470
28092
21508

63
85
111

43.43
59.12
77.21

94
128
167

65.15
88.68
115.82

125
170
222

86.87
118.23
154.43

156
213
278

108.58
147.79
193.04

188
256
334

130.30
177.35
231.64

219
298
389

152.02
206.91
270.25
108

250
341
445

173.73
236.47
308.86
123

400 RPM
M3/D

GPM

165T-5L
70
76
83
89
95
102

841 583.93
1001 694.93
1175 815.57
1363 945.87
1564 1085.82
**1780 **1235.44

165T-5M
51
57
64
70

165T-5H
38
44
51

31

46

62

77

92

*For operations below 200 RPM an auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.
**Requires Fluid King spherical valves for proper operation at listed RPM.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

200T-5 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 5" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
200T-5L

3 (76.2) API-2000# RTJ

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

6 (152.4) ANSI-150 F.F.

200T-5L

66-5/8"

55-1/2"

22-1/2"

200T-5M

2 (50.8) API-5000# RTJ

4 (101.6) ANSI-150 F.F.

200T-5M

65-3/4"

55-1/2"

22-1/2"

200T-5H

2 (50.8) ANSI-2000 RTJ

3 (76.2) API-2000# RTJ

200T-5H

65-1/4"

55-1/2"

22-1/2"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ............4 x 5 (101.6 x 127)
Rated BHP At 400 RPM (Kw) ...............................................................200 (149.1)
Rated Plunger Load (Kg) ..............................................................11,870 (5,384.2)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure .........................................................1,680 (11,584)
"M" Model Discharge Pressure ........................................................2,988 (20,602)
"H" Model Discharge Pressure.........................................................5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter..............................................................................................4-7/8 (123.8)
Length ...............................................................................................11-3/4 (298.0)
Keyway (Width x Depth)..........................................................1-1/4 x 5/8 (32 x 16)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter .............................................................3-1/2 (88.9)
Length..................................................................5-3/4 (146)
Keyway (Width x Depth) ..................7/8 x 7/16 (22.2 x 11.1)
Direct Drive: Diameter .............................................................3-1/2 (88.9)
Length..................................................................5-3/4 (146)
Keyway (Width x Depth) ..................7/8 x 7/16 (22.2 x 11.1)
Oil Capacity: Gallons (L)
Crankcase ...................................................................................................8 (30.3)
Gear Unit (Varies with Ratio) .............................................3.5 to 6.5 (13.2 to 24.6)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) .................4,486 (2,035)
Gear Unit - Lbs. (Kg) .............................................................................1,100 (499)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
2.27:1 Ratio
2.89:1 Ratio
4.38:1 Ratio
4.84:1 Ratio

3.25:1 Ratio

Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Bearing Access
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

200T-5/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM*

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

15.7437
18.4770
21.4289
24.5995
27.9888

0.4590
0.5387
0.6248
0.7172
0.8160

1680
1432
1234
1075
945

1574
1848
2143
2460
2799

45.90
53.87
62.48
71.72
81.60

2362
2772
3214
3690
4198

68.85
80.80
93.71
107.58
122.40

3149
3695
4286
4920
5598

91.80
107.74
124.95
143.44
163.20

3936
4619
5357
6150
6997

114.75
134.67
156.19
179.30
204.00

4723
5543
6429
7380
8397

137.70
161.61
187.43
215.16
244.80

5510
6467
7500
8610
9796

160.65
188.54
218.66
251.02
285.60

6297
7391
8572
9840
**11,195

183.60
215.48
249.90
286.88
**326.40

3.9761 8.8558 0.2582


4.9088 10.9331 0.3188
5.9396 13.2291 0.3857

2988
2419
2000

886
1093
1323

25.82
31.88
38.57

1328
1640
1984

38.73
47.81
57.85

1771
2187
2646

51.64
63.75
77.14

2214
2733
3307

64.55
79.69
96.42

2657
3280
3969

77.46
95.63
115.71

3100
3827
4630

90.37
111.56
134.99

3542
4373
5292

103.28
127.50
154.28

1.7672 3.9359 0.1148 5000


2.4053 5.3572 0.1562 4938
3.1416 6.9972 0.2040 3780
Brake Horsepower Required:

394
536
700

11.48
15.62
20.40

590
804
1050

17.21
23.43
30.60

787
1071
1399

22.95
31.24
40.80

984
1339
1749

28.69
39.05
51.00

1181
1607
2099

34.43
46.86
61.20

1378
1875
2449

40.16
54.67
71.40

1574
2143
2799

45.90
62.48
81.60
200

200T-5L
3
3 1/4
3 1/2
3 3/4
4

7.0686
8.2958
9.6212
11.0447
12.5664

200T-5M
2 1/4
2 1/2
2 3/4

200T-5H
1 1/2
1 3/4
2

50

75

100

125

150

175

100 RPM*

150 RPM*

200 RPM

250 RPM

300 RPM

350 RPM

Metric Units
M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

2.5031
2.9377
3.4070
3.9111
4.4499

1.7373
2.0389
2.3647
2.7146
3.0886

11584
9874
8508
7412
6516

250
294
341
391
445

173.73
203.89
236.47
271.46
308.86

375
441
511
587
667

260.60
305.84
354.70
407.18
463.28

501
588
681
782
890

347.46
407.79
472.94
542.91
617.71

626
734
852
978
1112

434.33
509.73
591.17
678.64
772.14

751
881
1022
1173
1335

521.19
611.68
709.40
814.37
926.57

876
1028
1192
1369
1557

608.06
713.63
827.64
950.09
1081.00

25.6522 1.4080
31.6694 1.7383
38.3200 2.1033

0.9772
1.2065
1.4598

20602
16679
13790

141
174
210

97.72
120.65
145.98

211
261
315

146.59
180.97
218.97

282
348
421

195.45
241.29
291.97

352
435
526

244.31
301.62
364.96

422
521
631

293.17
361.94
437.95

493
608
736

342.03
422.26
510.94

563
695
841

390.90
482.59
583.93

11.4010 0.6258 0.4343


15.5180 0.8517 0.5912
20.2684 1.1125 0.7721
Kilowatts Required:

34475
34048
26063

63
85
111

43.43
59.12
77.21

94
128
167

65.15
88.68
115.82

125
170
222

86.87
118.23
154.43

156
213
278

108.58
147.79
193.04

188
256
334

130.30
177.35
231.64
112

219
298
389

152.02
206.91
270.25
130

250
341
445

173.73
236.47
308.86
149

Plunger Plunger
Dia.
Area
mm
Sq. cm.

400 RPM
M3/D

GPM

200T-5L
76
83
89
95
102

45.6040
53.5213
62.0721
71.2562
81.0737

1001 694.93
1175 815.57
1363 945.87
1564 1085.82
**1780 **1235.44

200T-5M
57
64
70

200T-5H
38
44
51

37

56

75

93

*For operations below 200 RPM an auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.
**Requires Fluid King spherical valves for proper operation at listed RPM.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly A-336-H & A-346-H

Triplex Plunger Pump

202T-6 _

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium

This 6" stroke pump is designed for


a variety of fluid transfer applications
operating at low or medium pressures.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
202T-6L
202T-6M

3 (76.2) ANSI-600 L.R.


2-1/2 (63.5) ANSI-1500 L.R.

Dimensions
Suction Connection Size

Pump Type

6 (152.4) ANSI-150 F.F.


4 (101.6) ANSI-150 F.F.

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...4-1/4 x 6 (107.9 x 152.4)
Rated BHP At 320 RPM (Kw) .............................................................202 (150.58)
Rated Plunger Load (Kg) .................................................................12,500 (5,670)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure ..........................................................1,500 (10,342)
M Model Discharge Pressure.........................................................3,180 (21,925)
Crankshaft Extension: in. (mm)
Diameter ...........................................................................................4.495 (114.17)
Length ...............................................................................................8 3/8 (212.73)
Keyway (Width x Depth) ..........................................................1 x 3/8 (25.4 x 9.53)
Pinion Shaft Extension: in. (mm)
Diameter .............................................................................................3.438 (87.33)
Length ...............................................................................................7-3/8 (187.33)
Keyway (Width x Depth) ................................................7/8 x 7/16 (22.23 x 10.67)

Oil Capacity: Gallons (L)


Crankcase ...............................................................................................34 (128.7)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ...............3,952 (1792.6)

Length

Width

Height

202T-6L

73-1/8"

51-1/2"

28-5/8"

202T-6M

73-1/4"

51-1/2"

28-5/8"

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
1.59:1 Ratio
1.78:1 Ratio
2.487:1 Ratio
3.12:1 Ratio
4.44:1 Ratio
5.48:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Access Covers And Doors
Outside Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Frame Cradle
Removable Stuffing Boxes
Interchangeable Valves

202T-6/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger
Dia.
In.

Plunger
Area
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM*

200 RPM

250 RPM

300 RPM

320 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

7.0686
8.2958
9.6212
11.0447
12.5664
14.1863

18.89
22.17
25.71
29.52
33.59
37.92

0.5508
0.6464
0.7497
0.8606
0.9792
1.1054

1500
1500
1299
1132
995
881

1889
2217
2571
2952
3359
3792

55.08
64.64
74.97
86.06
97.92
110.54

2834
3326
3857
4428
5038
5687

82.62
96.96
112.46
129.09
146.88
165.81

3778
4434
5143
5904
6717
7583

110.16
129.29
149.94
172.13
195.84
221.09

4723
5543
6429
7380
8397
9479

137.70
161.61
187.43
215.16
244.80
276.36

5668
6652
7714
8856
10076
11375

165.24
193.93
224.91
258.19
293.76
331.63

6046
7095
8229
9446
10748
12133

176.26
206.86
239.90
275.40
313.34
353.74

3180
2546
2105
1768

840
1312
1587
1889

24.48
38.25
46.28
55.08

1259
1968
2381
2834

36.72
57.38
69.42
82.62

1679
2624
3175
3778

48.96
76.50
92.57
110.16

2099
3280
3969
4723

61.20
95.63
115.71
137.70

2519
3936
4762
5668

73.44
114.75
138.85
165.24

2687
4198
5080
6046

78.34
122.40
148.10
176.26

202T-6L
3
3 1/4
3 1/2
3 3/4
4
4 1/4

202T-6M
2
2 1/2
2 3/4
3

3.1416
8.40
0.2448
4.9088
13.12
0.3825
5.9396
15.87
0.4628
7.0686
18.89
0.5508
Brake Horsepower Required:

63

95

126

158

189

202

100 RPM*

150 RPM*

200 RPM

250 RPM

300 RPM

320 RPM

Metric Units
Plunger
Dia.
mm

Plunger
Area
Sq. cm.

M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

45.6040
53.5213
62.0721
71.2562
81.0737
91.5246

3.00
3.53
4.09
4.69
5.34
6.03

2.0848
2.4467
2.8376
3.2575
3.7063
4.1840

10342
10342
8958
7803
6858
6075

300
353
409
469
534
603

208.48
244.67
283.76
325.75
370.63
418.40

451
529
613
704
801
904

312.72
367.01
425.64
488.62
555.94
627.61

601
705
818
939
1068
1206

416.96
489.34
567.52
651.49
741.25
836.81

751
881
1022
1173
1335
1507

521.19
611.68
709.40
814.37
926.57
1046.01

901
1058
1227
1408
1602
1808

625.43
734.02
851.28
977.24
1111.88
1255.21

961
1128
1308
1502
1709
1929

667.13
782.95
908.04
1042.39
1186.01
1338.89

20.2684
1.33
0.9266
31.6694
2.09
1.4478
38.3200
2.52
1.7518
45.6040
3.00
2.0848
Kilowatts Required:

21925
17557
14510
12193

133
209
252
300

92.66
144.78
175.18
208.48

200
313
379
451

138.99
217.16
262.77
312.72

267
417
505
601

185.31
289.55
350.36
416.96

334
521
631
751

231.64
361.94
437.95
521.19

400
626
757
901

277.97
434.33
525.54
625.43

427
667
808
961

296.50
463.28
560.57
667.13

202T-6L
76
83
89
95
102
108

202T-6M
51
64
70
76

47

71

94

118

141

151

* For operations below 120 RPM an auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly A-536 & A-546

Quintuplex Plunger Pump

267Q-6_

Rated input horsepower


"Q" Quintuplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium

This 6" stroke pump is designed for a


variety of fluid transfer applications
operating at low or medium pressures.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size

Dimensions
Pump Type

Suction Connection Size

Length

Width

Height

267Q-6L

4 (101.61) ANSI-600 L.R.

6 (152.4) ANSI-300 F.F.

267Q-6L

73-1/4"

66-3/8"

28-1/2"

267Q-6M

3 (76.2) ANSI-1500 L.R.

4 (101.6) ANSI-300 F.F.

267Q-6M

73-1/4"

66-3/8"

28-1/2"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...4-1/4 x 6 (107.9 x 152.4)
Rated BHP At 360 RPM (Kw) .............................................................267 (199.04)
Rated Plunger Load (Kg) .................................................................10,000 (4,536)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure ............................................................1,420 (9,791)
M Model Discharge Pressure.........................................................3,180 (21,925)

Crankshaft Extension: in. (mm)


Diameter ...........................................................................................4.495 (114.17)
Length ...............................................................................................7-1/4 (184.15)
Keyway (Width x Depth) .........................................................1 x 3/8 (25.4 x 9.53)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ........................................................4.495 (114.17)
Length.............................................................8-3/4 (222.25)
Keyway (Width x Depth) ......................1 x 1/2 (25.4 x 12.7)
Direct Drive: Diameter ..........................................................3.375 (85.73)
Length...............................................................4-1/2 (114.3)
Keyway (Width x Depth) .................7/8 x 7/16 (22.2 x 10.7)

Oil Capacity: Gallons (L)


Crankcase .............................................................................................32 (121.13)
Gear Unit (Varies with Ratio).......................................5-1/4 to 7-1/2 (18.7 to 26.7)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ..................6,340 (2876)
Gear Unit - Lbs. (Kg) ...........................................................................2,219 (1006)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Bolt On Style Gear Reducers
2.698:1 Ratio
3.680:1 Ratio
5.500:1 Ratio
7.316:1 Ratio

9.500:1 Ratio

Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Access To Bearings
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes
Interchangeable Valves
267Q-6/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM Max.
Per Press.
RPM PSI

100 RPM*

150 RPM

BPD

GPM

BPD

3
7.0686 31.4874 0.9180 1420
3 1/4 8.2958 36.9540 1.0774 1200
3 1/2 9.6212 42.8579 1.2495 1040
3 3/4 11.0447 49.1991 1.4344 905
4
12.5664 55.9776 1.6320 795
4 1/4 14.1863 63.1935 1.8424 705

3149
3695
4286
4920
5598
6319

91.80
107.74
124.95
143.44
163.20
184.24

4723
5543
6429
7380
8397
9479

1399
1771
2187
2646
3149

40.80
51.64
63.75
77.14
91.80

2099
2657
3280
3969
4723

200 RPM

250 RPM

300 RPM

320 RPM**

360 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

Max.
PSI

137.70 6297
161.61 7391
187.43 8572
215.16 9840
244.80 11196
276.36 12639

183.60
215.48
249.90
286.88
326.40
368.48

7872
9238
10714
12300
13994
15798

229.50
269.34
312.38
358.59
408.00
460.59

9446
11086
12857
14760
16793
18958

275.40
323.21
374.85
430.31
489.60
552.71

10076
11825
13715
15744
17913
20222

293.76
344.76
399.84
459.00
522.24
589.56

1250
1060
920
800
705
625

11335
13303
15429
17712
20152
22750

81.60
103.28
127.50
154.28
183.60
168

3499
4428
5467
6615
7872

102.00
129.09
159.38
192.84
229.50
210

4198
5313
6560
7937
9446

122.40 4478 130.56


154.91 5668 165.24
191.25 6997 204.00
231.41 8467 246.84
275.40 10076 293.76
250
267

2800
2220
1800
1480
1250

5038 146.88
6376 185.90
7872 229.50
9525 277.70
11335 330.48
267

360 RPM
M3/D

GPM
1250.87
1468.03
1702.57
1954.48
2223.76
2510.42

GPM

BPD

GPM
330.48
387.86
449.82
516.38
587.52
663.26

267Q-6L

267Q-6M
2
2 1/4
2 1/2
2 3/4
3

3.1416 13.9944 0.4080 3180


3.9761 17.7117 0.5164 2520
4.9088 21.8663 0.6375 2040
5.9396 26.4582 0.7714 1680
7.0686 31.4874 0.9180 1420
Brake Horsepower Required:

84

61.20
77.46
95.63
115.71
137.70
126

2799
3542
4373
5292
6297

Metric Units
Plunger Plunger
Dia.
Area
mm Sq. cm.

M3/D
Per
RPM

L/Min Max.
100 RPM*
Per Press.
RPM kPa M3/D L/Min.

150 RPM
M3/D

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

Max.
Pres.
kPa

3.4746
4.0779
4.7294
5.4291
6.1771
6.9734

9791
8274
7171
6240
5481
4861

501
588
681
782
890
1005

347.46
407.79
472.94
542.91
617.71
697.34

751 521.19
881 611.68
1022 709.40
1173 814.37
1335 926.57
1507 1046.01

1001
1175
1363
1564
1780
2009

694.93
815.57
945.87
1085.82
1235.42
1394.68

1252
1469
1703
1956
2225
2512

868.66
1019.47
1182.34
1357.28
1544.28
1743.35

1502
1763
2044
2347
2670
3014

1042.39
1223.36
1418.81
1628.73
1853.14
2092.02

1602
1880
2180
2503
2848
3215

1111.88
1304.92
1513.39
1737.32
1976.68
2231.48

8619
7308
6343
5516
4861
4309

1802
2115
2453
2816
3204
3617

20.2684 2.2250 1.5443


25.6522 2.8160 1.9545
31.6694 3.4765 2.4129
38.3200 4.2066 2.9197
45.6040 5.0062 3.4746
Kilowatts Required:

21925
17374
14065
11583
9791

222
282
348
421
501

154.43
195.45
241.29
291.97
347.46

334
422
521
631
751

445
563
695
841
1001

308.86
390.90
482.59
583.93
694.93
126

556
704
869
1052
1252

386.07
488.62
603.23
729.91
868.66
157

712 494.17
901 625.43
1112 772.14
1346 934.29
1602 1111.88
201

19305
15306
12411
10204
8618

801 555.94
1014 703.61
1252 868.66
1514 1051.08
1802 1250.87
201

L/Min.

200 RPM

250 RPM

300 RPM

320 RPM**

267Q-6L
76
83
89
95
102
108

45.6040 5.0062
53.5213 5.8753
62.0721 6.8140
71.2562 7.8222
81.0737 8.8999
91.5246 10.0471

267Q-6M
51
57
64
70
76

63

231.64
293.17
361.94
437.95
521.19
94

667 463.28
845 586.34
1043 723.88
1262 875.90
1502 1042.39
188

* For operations below 100 RPM an auxiliary lubrication system is required.


** Pump speeds is excess of 320 RPM require specific approval of the manufacturer. Viscosity, temperature, velocities,
and other fluid properties of characteristics combined with the inherent mechanical efficiencies of pumps may result in
less than optimum operation. We have applied this conservatism to assure you of total performance.
Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly B-358-D & B-368-D

Triplex Plunger Pump

300TP-8 _

Rated input horsepower


"T" Triplex
"P" Internal Pinion
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High, "V" Very High

This 8" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Field Connections in. (mm)
Pump Model Discharge Connection Size

Performance Data >

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

300TP-8L

6 (152.4) ANSI-600 L.R.

8 (203.2) ANSI-150 F.F.

300TP-8L

87-3/8"

58-3/8"

49-1/4"

300TP-8M

4 (101.6) ANSI-900 L.R.

6 (152.4) ANSI-150 F.F.

300TP-8M

85-7/8"

58-3/8"

49-1/4"

300TP-8H

4 (101.6) ANSI-1500 L.R.

6 (152.4) ANSI-150 F.F.

300TP-8H

85-7/8"

58-3/8"

49-1/4"

300TP-8V

3 (76.2) ANSI-2500 RTJ

6 (152.4) ANSI-150 F.F.

300TP-8V

85-7/8"

58-3/8"

49-1/4"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...6-1/2 x 8 (165.1 x 203.2)
Rated BHP At 225 RPM (Kw) .............................................................300 (223.88)
Rated Plunger Load (Kg) .................................................................20,000 (9,072)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure ...............................................................925 (6,378)
M Model Discharge Pressure.........................................................1,590 (10,963)
H Model Discharge Pressure ........................................................ 2,410 (16,616)
V Model Discharge Pressure ........................................................ 3,690 (25,441)
Pinion Shaft Extension, if gear unit supplied (mm)
Diameter ...........................................................................................4.495 (114.17)
Length ...............................................................................................9-7/8 (250.83)
Keyway (Width x Depth) .........................................................1 x 1/2 (25.4 x 12.7)

Oil Capacity: Gallons (L)


Crankcase ...............................................................................................22 (83.28)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) .................8,725 (3,966)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Internal Pinion Gear:
4.07:1 Ratio (Standard)
3.28:1 Ratio (Optional)

2.02:1 Ratio (Optional)


5.23:1 Ratio (Optional)

Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Access Covers And Doors
Outside Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Cradle Frame
Removable Stuffing Boxes
Interchangeable Valves

300TP-8/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger
Dia.
In.

Plunger
Area
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

125 RPM

150 RPM

175 RPM

200 RPM

225 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

21.6476
23.7584
25.9673
28.2744
30.6797
33.1832

77.1441
84.6661
92.5380
100.7597
109.3313
118.2527

2.2491
2.4684
2.6979
2.9376
3.1875
3.4476

925
840
770
710
650
600

7714
8467
9254
10076
10933
11825

224.91
246.84
269.79
293.76
318.75
344.76

9643
10583
11567
12595
13666
14782

281.14
308.55
337.24
367.20
398.44
430.95

11572
12700
13881
15114
16400
17738

337.37
370.26
404.69
440.64
478.13
517.14

13500
14817
16194
17633
19133
20694

393.59
431.97
472.13
514.08
557.81
603.33

15429
16933
18508
20152
21866
23651

449.82
493.68
539.58
587.52
637.50
689.52

17357
19050
20821
22671
24600
26607

506.05
555.39
607.03
660.96
717.19
775.71

12.5664
14.1863
15.9044
17.7206
19.6350

44.7821
50.5548
56.6773
63.1497
69.9720

1.3056
1.4739
1.6524
1.8411
2.0400

1590
1410
1260
1130
1020

4478
5055
5668
6315
6997

130.56
147.39
165.24
184.11
204.00

5598
6319
7085
7894
8747

163.20
184.24
206.55
230.14
255.00

6717
7583
8502
9472
10496

195.84
221.09
247.86
276.17
306.00

7837
8847
9919
11051
12245

228.48
257.93
289.17
322.19
357.00

8956
10111
11335
12630
13994

261.12
294.78
330.48
368.22
408.00

10076
11375
12752
14209
15744

293.76
331.63
371.79
414.25
459.00

8.2958
9.6212
11.0447
12.5664
14.1863

29.5632
34.2863
39.3593
44.7821
50.5548

0.8619
0.9996
1.1475
1.3056
1.4739

2410
2080
1810
1590
1410

2956
3429
3936
4478
5055

86.19
99.96
114.75
130.56
147.39

3695
4286
4920
5598
6319

107.74
124.95
143.44
163.20
184.24

4434
5143
5904
6717
7583

129.29
149.94
172.13
195.84
221.09

5174
6000
6888
7837
8847

150.83
174.93
200.81
228.48
257.93

5913
6857
7872
8956
10111

172.38
199.92
229.50
261.12
294.78

6652
7714
8856
10076
11375

193.93
224.91
258.19
293.76
331.63

5.9396 21.1665 0.6171


3370
7.0686 25.1899 0.7344
2830
Brake Horsepower Required:

2117
2519

61.71
73.44

2646
3149

77.14
91.80

3175
3778

92.57
110.16

3704
4408

107.99
128.52

4233
5038

123.42
146.88

4762
5668

138.85
165.24

300TP-8L
5 1/4
5 1/2
5 3/4
6
6 1/4
6 1/2

300TP-8M
4
4 1/4
4 1/2
4 3/4
5

300TP-8H
3 1/4
3 1/2
3 3/4
4
4 1/4

300TP-8V
2 3/4
3

133

166

200

233

266

300

100 RPM*

125 RPM

150 RPM

175 RPM

200 RPM

225 RPM

Metric Units
Plunger
Dia.
mm

Plunger
Area
Sq. cm.

M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

139.6621
153.2800
167.5312
182.4159
197.9339
214.0853

12.2651
13.4611
14.7126
16.0198
17.3826
18.8010

8.5128
9.3429
10.2116
11.1188
12.0647
13.0492

6378
5791
5309
4895
4481
4137

1227
1346
1471
1602
1738
1880

851.28
934.29
1021.16
1111.88
1206.47
1304.92

1533
1683
1839
2002
2173
2350

1064.11
1167.86
1276.44
1389.85
1508.09
1631.15

1840
2019
2207
2403
2607
2820

1276.93
1401.43
1531.73
1667.82
1809.70
1957.37

2146
2356
2575
2803
3042
3290

1489.75
1635.01
1787.02
1945.79
2111.32
2283.60

2453
2692
2943
3204
3477
3760

1702.57
1868.58
2042.31
2223.76
2412.94
2609.83

2760
3029
3310
3604
3911
4230

1915.39
2102.15
2297.60
2501.73
2714.55
2936.06

81.0737
91.5246
102.6089
114.3266
126.6777

7.1199
8.0377
9.0111
10.0402
11.1248

4.9417
5.5787
6.2543
6.9686
7.7214

10963
9722
8687
7791
7033

712
804
901
1004
1112

494.17
557.87
625.43
696.86
772.14

890
1005
1126
1255
1391

617.71
697.34
781.79
871.07
965.18

1068
1206
1352
1506
1669

741.25
836.81
938.15
1045.28
1158.21

1246
1407
1577
1757
1947

864.80
976.27
1094.51
1219.50
1351.25

1424
1608
1802
2008
2225

988.34
1115.74
1250.87
1393.71
1544.28

1602
1808
2028
2259
2503

1111.88
1255.21
1407.23
1567.93
1737.32

53.5213
62.0721
71.2562
81.0737
91.5246

4.7002
5.4512
6.2577
7.1199
8.0377

3.2623
3.7835
4.3433
4.9417
5.5787

16616
14341
12480
10963
9722

470
545
626
712
804

326.23
378.35
434.33
494.17
557.87

588
681
782
890
1005

407.79
472.94
542.91
617.71
697.34

705
818
939
1068
1206

489.34
567.52
651.49
741.25
836.81

823
954
1095
1246
1407

570.90
662.11
760.08
864.80
976.27

940
1090
1252
1424
1608

652.46
756.70
868.66
988.34
1115.74

1058
1227
1408
1602
1808

734.02
851.28
977.24
1111.88
1255.21

300TP-8L
133
140
146
152
159
165

300TP-8M
102
108
114
121
127

300TP-8H
83
89
95
102
108

300TP-8V
70
76

38.3200 3.3653 2.3357 23235


337
233.57
421
291.97
505
350.36
589
408.75
673
467.14
757
525.54
45.6040 4.0049 2.7797 19512
400
277.97
501
347.46
601
416.96
701
486.45
801
555.94
901
625.43
Kilowatts Required:
100
126
151
176
201
226
* For operations below 50 RPM an auxiliary lubrication system is required. Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly J-275

Quintuplex Plunger Pump

300Q-5_

Rated input horsepower


"Q" Quintuplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 5" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size
300Q-5L

4 (101.6) API-2000# RTJ

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

8 (203.2) API# 150 F.F.

300Q-5L

67-1/8"

70-1/2"

23-3/16"

300Q-5M

3 (76.2) NSD-5000 RTJ

6 (152.4) NSD-600 RTJ

300Q-5M

64-1/4"

70-1/2"

23-3/16"

300Q-5H

2 (50.8) ANSI-2500# RTJ

6 (152.4) ANSI-600 RTJ

300Q-5H

64-1/4"

70-1/2"

23-3/16"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm)..................4 x 5 (102x127)
Rated BHP At 400 RPM (Kw) ..................................................................300 (224)
Rated Plunger Load (Kg) ..............................................................10,700 (4,853.5)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure ..........................................................1,650 (11,375)
M Model Discharge Pressure.........................................................3,000 (20,682)
H Model Discharge Pressure .........................................................5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter..............................................................................................4-7/8 (123.8)
Length (long side).......................................................................................12 (305)
Length (short side) .................................................................................6-1/2 (165)
Keyway (Width x Depth).........................................................1-1/4 x 5/8 (32 x 16)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Pinion Shaft Extension, if gear unit supplied (mm)
For Belt Or Chain Drive: Diameter ........................................................3-1/2 (88.9)
Length ................................................................................................5-11/16 (145)
Keyway (Width x Depth) ....................................................7/8 x 7/16 (22.2 x 11.1)
Oil Capacity: Gallons (L)
Crankcase .................................................................................................12 (45.5)
Gear Unit (Varies with Ratio) .................................................3.5 to 6.5 (13.2:24.6)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ..................7,000 (3175)
Gear Unit - Lbs. (Kg) .............................................................................1,100 (499)

Bolt On Style Gear Reducers


2.27:1 Ratio
2.89:1 Ratio
3.25:1 Ratio
4.38:1 Ratio
4.84:1 Ratio
5.63:1 Ratio
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features:

Horizontal Design
Large Power End Covers
Easy Access To Bearings
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes
Interchangeable Valves
300Q-5/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM

200 RPM

250 RPM

300 RPM

350 RPM

400 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

5.9396
7.0686
8.2958
9.6212
11.0447
12.5664

22.0485
26.2395
30.7950
35.7149
40.9992
46.6480

0.6428
0.7650
0.8978
1.0413
1.1953
1.3600

1650
1510
1290
1110
970
850

2205
2624
3079
3571
4100
4665

64.28
76.50
89.78
104.13
119.53
136.00

3307
3936
4619
5357
6150
6997

96.42
114.75
134.67
156.19
179.30
204.00

4410
5248
6159
7143
8200
9330

128.56
153.00
179.56
208.25
239.06
272.00

5512
6560
7699
8929
10250
11662

160.70
191.25
224.45
260.31
298.83
340.00

6615
7872
9238
10714
12300
13994

192.84
229.50
269.34
312.38
358.59
408.00

7717
9184
10778
12500
14350
16327

224.98
267.75
314.23
364.44
418.36
476.00

8819
10496
12318
14286
16400
n/a

257.13
306.00
359.13
416.50
478.13
n/a

3.1416
3.9761
4.9088
5.9396

11.6620
14.7597
18.2219
22.0485

0.3400
0.4303
0.5313
0.6428

3400
2690
2185
1800

1166
1476
1822
2205

34.00
43.03
53.13
64.28

1749
2214
2733
3307

51.00
64.55
79.69
96.42

2332
2952
3644
4410

68.00
86.06
106.25
128.56

2916
3690
4555
5512

85.00
107.58
132.81
160.70

3499
4428
5467
6615

102.00
129.09
159.38
192.84

4082
5166
6378
7717

119.00
150.61
185.94
224.98

4665
5904
7289
8819

136.00
172.13
212.50
257.13

1.7672 6.5599 0.1913 5000


2.4053 8.9287 0.2603 4450
3.1416 11.6620 0.3400 3400
Brake Horsepower Required:

656
893
1166

19.13
26.03
34.00

984
1339
1749

28.69
39.05
51.00

1312
1786
2332

38.25
52.06
68.00

1640
2232
2916

47.81
65.08
85.00

1968
2679
3499

57.38
78.09
102.00
225

2296
3125
4082

66.94
91.11
119.00
263

2624
3571
4665

76.50
104.13
136.00
300

300Q-5L
2 3/4
3
3 1/4
3 1/2
3 3/4
4

300Q-5M
2
2 1/4
2 1/2
2 3/4

300Q-5H
1 1/2
1 3/4
2

75

112

150

188

100 RPM*

150 RPM

200 RPM

250 RPM

Metric Units
M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

GPM

38.3200
45.6040
53.5213
62.0721
71.2562
81.0737

3.5055
4.1718
4.8961
5.6783
6.5185
7.4166

2.4330
2.8955
3.3982
3.9411
4.5243
5.1476

11375
10410
8893
7652
6687
5860

351
417
490
568
652
742

243.30
289.55
339.82
394.11
452.43
514.76

526
626
734
852
978
1112

364.96
434.33
509.73
591.17
678.64
772.14

701
834
979
1136
1304
1483

486.61
579.11
679.64
788.23
904.85
1029.52

876
1043
1224
1420
1630
1854

608.26
723.88
849.56
985.28
1131.06
1286.90

1052
1252
1469
1703
1956
2225

729.91
868.66
1019.47
1182.34
1357.28
1544.28

1227
1460
1714
1987
2281
2596

851.57
1013.43
1189.38
1379.40
1583.49
1801.66

1402
1669
1958
2271
2607
n/a

973.22
1158.21
1359.29
1576.45
1809.70
n/a

20.2684
25.6522
31.6694
38.3200

1.8541
2.3466
2.8971
3.5055

1.2869
1.6287
2.0108
2.4330

20682
18545
15063
12409

185
235
290
351

128.69
162.87
201.08
243.30

278
352
435
526

193.04
244.31
301.62
364.96

371
469
579
701

257.38
325.75
402.16
486.61

464
587
724
876

321.73
407.18
502.70
608.26

556
704
869
1052

386.07
488.62
603.23
729.91

649
821
1014
1227

450.42
570.06
703.77
851.57

742
939
1159
1402

514.76
651.49
804.31
973.22

11.4010 1.0430 0.7239


15.5180 1.4196 0.9853
20.2684 1.8541 1.2869
Kilowatts Required:

34470
30678
23440

104
142
185

72.39
98.53
128.69

156
213
278

108.58
147.79
193.04

209
284
371

144.78
197.06
257.38
112

261
355
464

180.97
246.32
321.73
140

313
426
556

217.16
295.58
386.07
168

365
497
649

253.36
344.85
450.42
196

417
568
742

289.55
394.11
514.76
224

Plunger Plunger
Dia.
Area
mm
Sq. cm.

300 RPM

350 RPM

400 RPM

300Q-5L
70
76
83
89
95
102

300Q-5M
51
57
64
70

300Q-5H
38
44
51

56

84

* For operations below 100 RPM an auxiliary lubrication system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly J-375

375T-7 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 7" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

10 (254) ANSI-150 F.F.

375T-7L

87-1/4"

79-11/16"

29"

4 (101.6) ANSI-1500 RTJ

6 (152.4) ANSI-300 F.F.

375T-7M

88-1/2"

79-11/16"

29"

3 (76.2) ANSI-2500 RTJ

6 (152.4) ANSI-300 F.F.

375T-7H

100"

79-11/16"

29"

375T-7L

6 (152.4) API-2000# RTJ

375T-7M
375T-7H

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...............5 x 7 (127 x 178)
Rated BHP At 286 RPM (Kw) ..................................................................375 (280)
Rated Plunger Load (Kg) ...............................................................22,200 (10,070)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure ........................................................ 1,550 (10,686)
"M" Model Discharge Pressure ....................................................... 3,150 (21,716)
"H" Model Discharge Pressure........................................................ 5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter ....................................................................................................6 (152.4)
Length .............................................................................................10-3/16 (258.9)
Keyway (Width x Depth)....................................................1-1/2 x 3/4 (38.1 x 19.0)
Oil Capacity: Gallons: (L)
Crankcase .................................................................................................22 (83.6)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ...............10,500 (4,763)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Bearing Access
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

375T-7/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM

200 RPM

225 RPM

250 RPM

275 RPM

286 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

14.1863
15.9044
17.7206
19.6350

44.2354
49.5927
55.2560
61.2255

1.2897
1.4459
1.6110
1.7850

1550
1399
1256
1133

4424
4959
5526
6123

128.97
144.59
161.10
178.50

6635
7439
8288
9184

193.45
216.88
241.64
267.75

8847
9919
11051
12245

257.93
289.17
322.19
357.00

9953
11158
12433
13776

290.17
325.32
362.47
401.63

11059
12398
13814
15306

322.42
361.46
402.74
446.25

12165
13638
15195
16837

354.66
397.61
443.01
490.88

12651
14183
15803
17510

368.84
413.51
460.74
510.51

7.0686
8.2958
9.6212
11.0447
12.5664

22.0412
25.8678
30.0005
34.4393
39.1843

0.6426
0.7542
0.8747
1.0041
1.1424

3150
2682
2313
2015
1771

2204
2587
3000
3444
3918

64.26
75.42
87.47
100.41
114.24

3306
3880
4500
5166
5878

96.39
113.12
131.20
150.61
171.36

4408
5174
6000
6888
7837

128.52
150.83
174.93
200.81
228.48

4959
5820
6750
7749
8816

144.59
169.69
196.80
225.91
257.04

5510
6467
7500
8610
9796

160.65
188.54
218.66
251.02
285.60

6061
7114
8250
9471
10776

176.72
207.39
240.53
276.12
314.16

6304
7398
8580
9850
11207

183.78
215.69
250.15
287.16
326.73

4.9088 15.3064 0.4463 4533


5.9396 18.5207 0.5400 3747
7.0686 22.0412 0.6426 3150
Brake Horsepower Required:

1531
1852
2204

44.63
54.00
64.26

2296
2778
3306

66.94
80.99
96.39

3061
3704
4408

89.25
107.99
128.52
262

3444
4167
4959

100.41
121.49
144.59
295

3827
4630
5510

111.56
134.99
160.65
328

4209
5093
6061

122.72
148.49
176.72
361

4378
5297
6304

375T-7L
4 1/4
4 1/2
4 3/4
5

375T-7M
3
3 1/4
3 1/2
3 3/4
4

375T-7H
2 1/2
2 3/4
3

131

197

100 RPM*

150 RPM

127.63
154.43
183.78
375

Metric Units
M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

91.5246
102.6089
114.3266
126.6777

7.0330
7.8847
8.7852
9.7342

4.8814
5.4725
6.0975
6.7562

10686
9646
8657
7813

703
788
879
973

488.14
547.25
609.75
675.62

1055
1183
1318
1460

732.21
820.88
914.62
1013.43

1407
1577
1757
1947

976.27
1094.51
1219.50
1351.25

1582
1774
1977
2190

1098.31
1231.32
1371.94
1520.15

1758
1971
2196
2434

1220.34
1368.14
1524.37
1689.06

1934
2168
2416
2677

1342.38
1504.95
1676.81
1857.96

2011
2255
2513
2784

1396.07
1565.15
1743.88
1932.28

45.6040
53.5213
62.0721
71.2562
81.0737

3.5043
4.1127
4.7698
5.4755
6.2299

2.4322
2.8545
3.3106
3.8004
4.3240

21716
18493
15945
13890
12208

350
411
477
548
623

243.22
285.45
331.06
380.04
432.40

526
617
715
821
934

364.84
428.18
496.58
570.06
648.60

701
823
954
1095
1246

486.45
570.90
662.11
760.08
864.80

788
925
1073
1232
1402

547.25
642.26
744.87
855.08
972.90

876
1028
1192
1369
1557

608.06
713.63
827.64
950.09
1081.00

964
1131
1312
1506
1713

668.87
784.99
910.40
1045.10
1189.10

1002 695.62
1176 816.39
1364 946.82
1566 1086.91
1782 1236.66

31.6694 2.4336 1.6891


38.3200 2.9446 2.0438
45.6040 3.5043 2.4322
Kilowatts Required:

31253
25829
21716

243
294
350

168.91
204.38
243.22

365
442
526

253.36
306.56
364.84
147

487
589
701

337.81
408.75
486.45
196

548
663
788

380.04
459.85
547.25
220

608
736
876

422.26
510.94
608.06
244

669
810
964

464.49
562.03
668.87
269

Plunger Plunger
Dia.
Area
mm
Sq. cm.

200 RPM

225 RPM

250 RPM

275 RPM

286 RPM

375T-7L
108
114
121
127

375T-7M
76
83
89
95
102

375T-7H
64
70
76

98

696
842
1002

483.07
584.51
695.62
280

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

430T-7 _

Triplex Plunger Pump

Rated input horsepower


"T" Triplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 7" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

10 (254) ANSI-150 F.F.

430T-7L

87-1/4"

79-11/16"

29"

4 (101.6) ANSI-1500 RTJ

6 (152.4) ANSI-300 F.F.

430T-7M

88-1/2"

79-11/16"

29"

3 (76.2) ANSI-2500 RTJ

6 (152.4) ANSI-300 F.F.

430T-7H

100"

79-11/16"

29"

430T-7L

6 (152.4) API-2000# RTJ

430T-7M
430T-7H

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm)...............5 x 7 (127 x 178)
Rated BHP At 300 RPM (Kw)...................................................................430 (321)
Rated Plunger Load (Kg)................................................................24,500 (11,136)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure..........................................................1,727 (11,910)
M Model Discharge Pressure ........................................................3,466 (23,903)
H Model Discharge Pressure .........................................................5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter ....................................................................................................6 (152.4)
Length .............................................................................................10-3/16 (258.9)
Keyway (Width x Depth) ...................................................1-1/2 x 3/4 (38.1 x 19.0)
Oil Capacity: Gallons: (L)
Crankcase .................................................................................................22 (83.6)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ..............10,500 (4,763)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Bearing Access
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

430T-7/6.99

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)

< Return To Specs

English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM

200 RPM

225 RPM

250 RPM

275 RPM

300 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

14.1863
15.9044
17.7206
19.6350

44.2354
49.5927
55.2560
61.2255

1.2897
1.4459
1.6110
1.7850

1727
1540
1383
1247

4424
4959
5526
6123

128.97
144.59
161.10
178.50

6635
7439
8288
9184

193.45
216.88
241.64
267.75

8847
9919
11051
12245

257.93
289.17
322.19
357.00

9953
11158
12433
13776

290.17
325.32
362.47
401.63

11059
12398
13814
15306

322.42
361.46
402.74
446.25

12165
13638
15195
16837

354.66
397.61
443.01
490.88

13271
14878
16577
18368

386.90
433.76
483.29
535.50

7.0686
8.2958
9.6212
11.0447
12.5664

22.0412
25.8678
30.0005
34.4393
39.1843

0.6426
0.7542
0.8747
1.0041
1.1424

3466
2953
2546
2218
1950

2204
2587
3000
3444
3918

64.26
75.42
87.47
100.41
114.24

3306
3880
4500
5166
5878

96.39
113.12
131.20
150.61
171.36

4408
5174
6000
6888
7837

128.52
150.83
174.93
200.81
228.48

4959
5820
6750
7749
8816

144.59
169.69
196.80
225.91
257.04

5510
6467
7500
8610
9796

160.65
188.54
218.66
251.02
285.60

6061
7114
8250
9471
10776

176.72
207.39
240.53
276.12
314.16

6612
7760
9000
10332
11755

192.78
226.25
262.40
301.22
342.72

4.9088 15.3064 0.4463 4990


5.9396 18.5207 0.5400 4125
7.0686 22.0412 0.6426 3466
Brake Horsepower Required:

1531
1852
2204

44.63
54.00
64.26

2296
2778
3306

66.94
80.99
96.39

3061
3704
4408

89.25
107.99
128.52
289

3444
4167
4959

100.41
121.49
144.59
325

3827
4630
5510

111.56
134.99
160.65
361

4209
5093
6061

122.72
148.49
176.72
397

4592
5556
6612

430T-7L
4 1/4
4 1/2
4 3/4
5

430T-7M
3
3 1/4
3 1/2
3 3/4
4

430T-7H
2 1/2
2 3/4
3

144

217

100 RPM*

150 RPM

133.88
161.99
192.78
430

Metric Units
M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

91.5246
102.6089
114.3266
126.6777

7.0330
7.8847
8.7852
9.7342

4.8814
5.4725
6.0975
6.7562

11910
10620
9538
8600

703
788
879
973

488.14
547.25
609.75
675.62

1055
1183
1318
1460

732.21
820.88
914.62
1013.43

1407
1577
1757
1947

976.27
1094.51
1219.50
1351.25

1582
1774
1977
2190

1098.31
1231.32
1371.94
1520.15

1758
1971
2196
2434

1220.34
1368.14
1524.37
1689.06

1934
2168
2416
2677

1342.38
1504.95
1676.81
1857.96

2110
2365
2636
2920

1464.41
1641.76
1829.25
2026.87

45.6040
53.5213
62.0721
71.2562
81.0737

3.5043
4.1127
4.7698
5.4755
6.2299

2.4322
2.8545
3.3106
3.8004
4.3240

23903
20366
17559
15297
13448

350
411
477
548
623

243.22
285.45
331.06
380.04
432.40

526
617
715
821
934

364.84
428.18
496.58
570.06
648.60

701
823
954
1095
1246

486.45
570.90
662.11
760.08
864.80

788
925
1073
1232
1402

547.25
642.26
744.87
855.08
972.90

876
1028
1192
1369
1557

608.06
713.63
827.64
950.09
1081.00

964
1131
1312
1506
1713

668.87
784.99
910.40
1045.10
1189.10

1051 729.67
1234 856.35
1431 993.17
1643 1140.11
1869 1297.20

31.6694 2.4336 1.6891


38.3200 2.9446 2.0438
45.6040 3.5043 2.4322
Kilowatts Required:

34414
28448
23903

243
294
350

168.91
204.38
243.22
107

365
442
526

253.36
306.56
364.84
162

487
589
701

337.81
408.75
486.45
216

548
663
788

380.04
459.85
547.25
242

608
736
876

422.26
510.94
608.06
269

669
810
964

464.49
562.03
668.87
296

Plunger Plunger
Dia.
Area
mm Sq. cm.

200 RPM

225 RPM

250 RPM

275 RPM

300 RPM

430T-7L
108
114
121
127

430T-7M
76
83
89
95
102

430T-7H
64
70
76

730
883
1051

506.72
613.13
729.67
321

Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general
information only. Applications suggested for the materials and
other information are described only to help readers make
their own evaluations and decisions, and are neither
guarantees nor are they to be construed as express or
implied warranties of suitability for these or other applications.
National Oilwell makes no warranty, either express or implied,
beyond that stipulated in National Oilwells Standard Terms
and Conditions of Sale which are available upon request.

Formerly J-625

625Q-7_

Quintuplex Plunger Pump

Rated input horsepower


"Q" Quintuplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium, "H" High

This 7" stroke pump is


designed for a variety of
fluid transfer applications
operating at low, medium
or high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

10 (254) ANSI-150 F.F.

625Q-7L

90-5/8"

108-1/2"

29-3/4"

4 (101.6) ANSI-1500 RTJ

6 (152.4) ANSI-300 F.F.

625Q-7M

87-5/8"

108-1/2"

29-3/4"

3 (76.2) ANSI-2500 RTJ

6 (152.4) ANSI-300 F.F.

625Q-7H

100-5/8"

108-1/2"

29-3/4"

625Q-7L

6 (152.4) API-2000# RTJ

625Q-7M
625Q-7H

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...............5 x 7 (127 x 178)
Rated BHP At 286 RPM (Kw) ..................................................................625 (466)
Rated Plunger Load (Kg) ...............................................................22,200 (10,070)
Maximum Working Pressure: PSI (kPa)
"L" Model Discharge Pressure .........................................................1,550 (10,686)
"M" Model Discharge Pressure ........................................................3,150 (21,716)
"H" Model Discharge Pressure.........................................................5,000 (34,473)
Crankshaft Extension: in. (mm)
Diameter ....................................................................................................6 (152.4)
Length (Long Side)...............................................................................14-7/8 (378)
Length (Short Side)................................................................................7-5/8 (194)
Keyway (Width x Depth)....................................................1-1/4 x 5/8 (31.8 x 15.9)
Oil Capacity: Gallons: (L)
Crankcase ............................................................................................33-1/2 (127)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ...............18,000 (8,165)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service or Kevlar Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy To Access Bearings
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes
Interchangeable Valves

000X-0/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger Plunger
Dia.
Area
In.
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM*

150 RPM

200 RPM

225 RPM

250 RPM

275 RPM

286 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

14.186
15.904
17.721
19.635

73.7257
82.6544
92.0934
102.0425

2.1494
2.4098
2.6849
2.9750

1550
1400
1250
1125

7373
8265
9209
10204

214.94
240.98
268.49
297.50

11059
12398
13814
15306

322.42
361.46
402.74
446.25

14745
16531
18419
20409

429.89
481.95
536.99
595.00

16588
18597
20721
22960

483.62
542.19
604.11
669.38

18431
20664
23023
25511

537.36
602.44
671.23
743.75

20275
22730
25326
28062

591.10
662.68
738.36
818.13

21086
23639
26339
29184

614.74
689.19
767.89
850.85

7.069
8.296
9.621
11.045
12.566

36.7353
43.1130
50.0008
57.3989
65.3072

1.0710
1.2569
1.4578
1.6734
1.9040

3150
2675
2300
2000
1775

3674
4311
5000
5740
6531

107.10
125.69
145.78
167.34
190.40

5510
6467
7500
8610
9796

160.65
188.54
218.66
251.02
285.60

7347
8623
10000
11480
13061

214.20
251.39
291.55
334.69
380.80

8265
9700
11250
12915
14694

240.98
282.81
327.99
376.52
428.40

9184
10778
12500
14350
16327

267.75
314.23
364.44
418.36
476.00

10102
11856
13750
15785
17959

294.53
345.66
400.88
460.20
523.60

10506
12330
14300
16416
18678

306.31
359.48
416.92
478.60
544.54

4.909 25.5106 0.7438 5000


5.940 30.8679 0.8999 3750
7.069 36.7353 1.0710 3150
Brake Horsepower Required:

2551
3087
3674

74.38
89.99
107.10
218

3827
4630
5510

111.56
134.99
160.65
338

5102
6174
7347

148.75
179.99
214.20
437

5740
6945
8265

167.34
202.49
240.98
491

6378
7717
9184

185.94
224.98
267.75
547

625Q-7L
4 1/4
4 1/2
4 3/4
5

625Q-7M
3
3 1/4
3 1/2
3 3/4
4

625Q-7H
2 1/2
2 3/4
3

7015 204.53
8489 247.48
10102 294.53
600

7296 212.71
8828 257.38
10506 306.31
625

275 RPM

286 RPM

Metric Units
M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

11.7217
13.1412
14.6419
16.2237

8.1356
9.1209
10.1625
11.2604

10687
9653
8618
7757

1172
1314
1464
1622

813.56
912.09
1016.25
1126.04

1758
1971
2196
2434

1220.34
1368.14
1524.37
1689.06

2344
2628
2928
3245

1627.12
1824.18
2032.50
2252.08

2637
2957
3294
3650

1830.51
2052.20
2286.56
2533.58

2930
3285
3660
4056

2033.91
2280.23
2540.62
2815.09

3223
3614
4027
4462

2237.30
2508.25
2794.68
3096.60

3352
3758
4188
4640

2326.79
2608.58
2906.47
3220.47

45.604 5.8405
53.521 6.8545
62.072 7.9496
71.256 9.1259
81.074 10.3832

4.0537
4.7575
5.5176
6.3340
7.2066

21719
18443
15858
13790
12238

584
685
795
913
1038

405.37
475.75
551.76
633.40
720.66

876
1028
1192
1369
1557

608.06
713.63
827.64
950.09
1081.00

1168
1371
1590
1825
2077

810.75
951.50
1103.52
1266.79
1441.33

1314
1542
1789
2053
2336

912.09
1070.44
1241.46
1425.14
1621.49

1460
1714
1987
2281
2596

1013.43
1189.38
1379.40
1583.49
1801.66

1606
1885
2186
2510
2855

1114.78
1308.31
1517.34
1741.84
1981.83

1670
1960
2274
2610
2970

1159.37
1360.65
1578.03
1811.51
2061.10

31.669 4.0559 2.8151


38.320 4.9077 3.4063
45.604 5.8405 4.0537
Kilowatts Required:

34474
25855
21719

406
491
584

281.51
340.63
405.37
163

608
736
876

422.26
510.94
608.06
252

811
982
1168

563.02
681.25
810.75
326

913
1104
1314

633.40
766.41
912.09
366

1014
1227
1460

703.77
851.57
1013.43
408

1115
1350
1606

774.15
936.72
1114.78
448

Plunger Plunger
Dia.
Area
mm
Sq. cm.

100 RPM*

150 RPM

200 RPM

225 RPM

250 RPM

625Q-7L
108
114
121
127

91.525
102.609
114.327
126.678

625Q-7M
76
83
89
95
102

625Q-7H
64
70
76

1160 805.12
1404 974.19
1670 1159.37
466

* For operations below 100 RPM an auxiliary lube system is required.


Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly B-558, C-548

Quintuplex Plunger Pump

630Q-8_

Rated input horsepower


"Q" Quintuplex
Stroke length (in.)
Fluid end pressure ranges
"L" Low, "M" Medium

This 8" stroke pump is designed for a


variety of fluid transfer applications
operating at lo or, medium pressures.

Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

630Q-8L

4 (101.6) ANSI-900 L.R.

8 (203.2) ANSI-300 F.F.

630Q-8L

93-3/4"

86"

37"

630Q-8M

4 (101.6) ANSI-1500 RTJ

6 (152.4) ANSI-300 F.F.

630Q-8M

87-3/4"

86"

37"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) .........5-1/2 x 8 (140 x 203)
Rated BHP At 225 RPM (Kw) ..................................................................630 (471)
Rated Plunger Load (Kg) ...............................................................25,000 (11,340)
Maximum Working Pressure: PSI (kPa)
L Model Discharge Pressure ..........................................................1,765 (12,150)
M Model Discharge Pressure.........................................................3,000 (20,684)
Crankshaft Extension, (mm)
Diameter..............................................................................................6-1/2 (165.1)
Length .................................................................................................9-1/2 (241.3)
Keyway (Width x Depth)...................................................1-1/2 x 1/2 (38.1 x 12.7)
Oil Capacity: Gallons (L)
Crankcase ..................................................................................................32 (121)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ...............16,260 (7,375)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves (Some models)
Double Extended Crankshaft (Some models)
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
External Heat Exchanger
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Access Covers And Doors
Outside Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Cradle Frame
Removable Stuffing Boxes
Interchangeable Valves

630Q-8L,M/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger
Dia.
In.

Plunger
Area
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

125 RPM

150 RPM

175 RPM

200 RPM

225 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

14.1863
15.9044
17.7206
19.6350
21.6476
23.7584

84.2580
94.4622
105.2496
116.6200
128.5736
141.1102

2.4565
2.7540
3.0685
3.4000
3.7485
4.1140

1,765
1,575
1,415
1,270
1,160
1,050

8426
9446
10525
11662
12857
14111

245.65
275.40
306.85
340.00
374.85
411.40

10532
11808
13156
14578
16072
17639

307.06
344.25
383.56
425.00
468.56
514.25

12639
14169
15787
17493
19286
21167

368.48
413.10
460.28
510.00
562.28
617.10

14745
16531
18419
20409
22500
24694

429.89
481.95
536.99
595.00
655.99
719.95

16852
18892
21050
23324
25715
28222

491.30
550.80
613.70
680.00
749.70
822.80

18958
21254
23681
26240
28929
31750

552.71
619.65
690.41
765.00
843.41
925.65

3,000
2,600
2,260
2,000

4927
5714
6560
7464

143.65
166.60
191.25
217.60

6159
7143
8200
9330

179.56
208.25
239.06
272.00

7391
8572
9840
11196

215.48
249.90
286.88
326.40

8623
10000
11480
13061

251.39
291.55
334.69
380.80

9854
11429
13120
14927

287.30
333.20
382.50
435.20

11086
12857
14760
16793

323.21
374.85
430.31
489.60

630Q-8L
4 1/4
4 1/2
4 3/4
5
5 1/4
5 1/2

630Q-8M
3 1/4
3 1/2
3 3/4
4

8.2958 49.2720 1.4365


9.6212 57.1438 1.6660
11.0447 65.5988 1.9125
12.5664 74.6368 2.1760
Brake Horsepower Required:

280

350

420

490

560

630

100 RPM

125 RPM

150 RPM

175 RPM

200 RPM

225 RPM

Metric Units
Plunger
Dia.
mm

Plunger
Area
Sq. cm.

M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

91.5246
102.6089
114.3266
126.6777
139.6621
153.2800

13.3962
15.0185
16.7336
18.5414
20.4419
22.4351

9.2979
10.4239
11.6143
12.8690
14.1881
15.5715

12,150
10,838
9,727
8,779
7,963
7,255

1340
1502
1673
1854
2044
2244

929.79
1042.39
1161.43
1286.90
1418.81
1557.15

1675
1877
2092
2318
2555
2804

1162.23
1302.99
1451.78
1608.63
1773.51
1946.44

2009
2253
2510
2781
3066
3365

1394.68
1563.58
1742.14
1930.35
2128.21
2335.72

2344
2628
2928
3245
3577
3926

1627.12
1824.18
2032.50
2252.08
2482.91
2725.01

2679
3004
3347
3708
4088
4487

1859.57
2084.78
2322.85
2573.80
2837.61
3114.30

3014
3379
3765
4172
4599
5048

2092.02
2345.38
2613.21
2895.53
3192.32
3503.59

53.5213 7.8337 5.4372


62.0721 9.0853 6.3058
71.2562 10.4295 7.2388
81.0737 11.8665 8.2362
Kilowatts Required:

20,684
17,916
15,607
13,717

783
909
1043
1187

543.72
630.58
723.88
823.62

979
1136
1304
1483

679.64
788.23
904.85
1029.52
262

1175
1363
1564
1780

815.57
945.87
1085.82
1235.42
314

1371
1590
1825
2077

951.50
1103.52
1266.79
1441.33
366

1567
1817
2086
2373

1087.43
1261.16
1447.76
1647.23
418

1763
2044
2347
2670

1223.36
1418.81
1628.73
1853.14
471

630Q-8L
108
114
121
127
133
140

630Q-8M
83
89
95
102

209

* Pumps applied above 400 HP and above 298 Kw. require a lube oil heat exchanger.
Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Formerly C-528, C-538, D-548

Quintuplex Plunger Pump

630Q-8_

Rated input horsepower


"Q" Quintuplex
Stroke length (in.)
Fluid end pressure ranges
"H" High, "V" Very High, "U" Ultra High

This 8" stroke pump is


designed for a variety of
fluid transfer applications
operating at high, very high
or ultra high pressures.
Performance Data >

Field Connections in. (mm)


Pump Model Discharge Connection Size

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

630Q-8H

6 (152.4) ANSI-1500 RTJ

8 (203.2) ANSI-300 F.F.

630Q-8H

102-1/4"

86"

39-1/2"

630Q-8V

4 (101.6) ANSI-2500 RTJ

6 (152.4) ANSI-300 F.F.

630Q-8V

109-13/16"

86"

47-15/16"

630Q-8U

3 (76.2) ANSI-2500 RTJ

6 (152.4) ANSI-300 F.F.

630Q-8U

109"

86"

47-1/8"

Pump Specifications
630Q-8H
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...............5 x 8 (127 x 203)
Rated BHP At 225 RPM (Kw) ..................................................................630 (471)
Rated Plunger Load (Kg) ...............................................................25,000 (11,340)
630Q-8V
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...........3-1/2 x 8 (89 x 203)
Rated BHP At 225 RPM (Kw) ..................................................................630 (471)
Rated Plunger Load (Kg) ...............................................................25,000 (11,340)
630Q-8U
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...........2-5/8 x 8 (67 x 203)
Rated BHP At 225 RPM (Kw) ..................................................................630 (471)
Rated Plunger Load (Kg) ...............................................................25,000 (11,340)
Maximum Working Pressure: PSI (kPa)
H Model Discharge Pressure .........................................................3,500 (24,161)
V Model Discharge Pressure .........................................................4,000 (27,579)
U Model Discharge Pressure .........................................................6,000 (41,369)
Crankshaft Extension, (mm)
Diameter..............................................................................................6-1/2 (165.1)
Length .................................................................................................9-1/2 (241.3)
Keyway (Width x Depth)...................................................1-1/2 x 1/2 (38.1 x 12.7)
Oil Capacity: Gallons (L)
Crankcase ..................................................................................................32 (121)

Standard Equipment
Aluminum Bronze Fluid End
Aluminum Bronze Valve Covers
Aluminum Bronze or Stainless Steel Stuffing Boxes
Bronze Stuffing Box Internals
Ceramic or Tungsten Carbide Plungers
General Service Plunger Packing
Stainless Steel Intermediate Rods
Fluid King Spherical Valves (Some models)
Double Extended Crankshaft (Some models)
Oil Level Dipstick
Crankcase Breather

Optional Equipment
Alternate Fluid End Materials
Alternate Fluid End Valve Styles
External Heat Exchanger
Custom Designs For Specialized Applications

Accessories
Packing Lubricator
Pulsation Dampeners
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Access Covers And Doors
Outside Access For Bearing Adjustment
Separate Crosshead/Plunger Construction
Open Cradle Frame
Removable Stuffing Boxes
Interchangeable Valves

Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg)


630Q-8H ...........................................................................................15,361 (6,968)
630Q-8V ...........................................................................................13,262 (6,016)
630Q-8U ...........................................................................................14,200 (6,441)
630Q-8H,V,U/6.99

< Return To Specs

Continuous Duty Performance Data (Volumes Indicated Are Displacement of Incompressible Fluid)
English Units
Plunger
Dia.
In.

Plunger
Area
Sq. In.

BPD
Per
RPM

GPM
Per
RPM

Max.
Press.
PSI

100 RPM

125 RPM

150 RPM

175 RPM

200 RPM

225 RPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

7.0686
8.2958
9.6212
11.0447
12.5664
14.1863
15.9044
17.7206
19.6350

41.9832
49.2720
57.1438
65.5988
74.6368
84.2580
94.4622
105.2496
116.6200

1.2240
1.4365
1.6660
1.9125
2.1760
2.4565
2.7540
3.0685
3.4000

3,500
3,000
2,600
2,260
2,000
1,765
1,575
1,415
1,270

4198
4927
5714
6560
7464
8426
9446
10525
11662

122.40
143.65
166.60
191.25
217.60
245.65
275.40
306.85
340.00

5248
6159
7143
8200
9330
10532
11808
13156
14578

153.00
179.56
208.25
239.06
272.00
307.06
344.25
383.56
425.00

6297
7391
8572
9840
11196
12639
14169
15787
17493

183.60
215.48
249.90
286.88
326.40
368.48
413.10
460.28
510.00

7347
8623
10000
11480
13061
14745
16531
18419
20409

214.20
251.39
291.55
334.69
380.80
429.89
481.95
536.99
595.00

8397
9854
11429
13120
14927
16852
18892
21050
23324

244.80
287.30
333.20
382.50
435.20
491.30
550.80
613.70
680.00

9446
11086
12857
14760
16793
18958
21254
23681
26240

275.40
323.2
374.85
430.31
489.60
552.71
619.65
690.41
765.00

4.9088
5.9396
7.0686
8.2958
9.6212

29.1550
35.2776
41.9832
49.2720
57.1438

0.8500
1.0285
1.2240
1.4365
1.6660

4,000
4,000
3,540
3,000
2,570

2916
3528
4198
4927
5714

85.00
102.85
122.40
143.65
166.60

3644
4410
5248
6159
7143

106.25
128.56
153.00
179.56
208.25

4373
5292
6297
7391
8572

127.50
154.28
183.60
215.48
249.90

5102
6174
7347
8623
10000

148.75
179.99
214.20
251.39
291.55

5831
7056
8397
9854
11429

170.00
205.70
244.80
287.30
333.20

6560
7937
9446
11086
12857

191.25
231.41
275.40
323.21
374.85

3.9761 23.6156 0.6885


6,000
4.9088 29.1550 0.8500
5,090
Brake Horsepower Required:

2362
2916

68.85
85.00

2952
3644

86.06
106.25

3542
4373

103.28
127.50

4133
5102

120.49
148.75

4723
5831

137.70
170.00

5313
6560

154.91
191.25

630Q-8H
3
3 1/4
3 1/2
3 3/4
4
4 1/4
4 1/2
4 3/4
5

630Q-8V
2 1/2
2 3/4
3
3 1/4
3 1/2

630Q-8U
2 1/4
2 1/2

280

350

420

490

560

630

100 RPM

125 RPM

150 RPM

175 RPM

200 RPM

225 RPM

Metric Units
Plunger
Dia.
mm

Plunger
Area
Sq. cm.

M3/D
Per
RPM

L/Min
Per
RPM

Max.
Press.
kPa

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

M3/D

L/Min.

45.6040
53.5213
62.0721
71.2562
81.0737
91.5246
102.6089
114.3266
126.6777

6.6749
7.8337
9.0853
10.4295
11.8665
13.3962
15.0185
16.7336
18.5414

4.6328
5.4372
6.3058
7.2388
8.2362
9.2979
10.4239
11.6143
12.8690

24,131
20,778
17,916
15,607
13,717
12,150
10,838
9,727
8,779

667
783
909
1043
1187
1340
1502
1673
1854

463.28
543.72
630.58
723.88
823.62
929.79
1042.39
1161.43
1286.90

834
979
1136
1304
1483
1675
1877
2092
2318

579.11
679.64
788.23
904.85
1029.52
1162.23
1302.99
1451.78
1608.63

1001
1175
1363
1564
1780
2009
2253
2510
2781

694.93
815.57
945.87
1085.82
1235.42
1394.68
1563.58
1742.14
1930.35

1168
1371
1590
1825
2077
2344
2628
2928
3245

810.75
951.50
1103.52
1266.79
1441.33
1627.12
1824.18
2032.50
2252.08

1335
1567
1817
2086
2373
2679
3004
3347
3708

926.57
1087.43
1261.16
1447.76
1647.23
1859.57
2084.78
2322.85
2573.80

1502
1763
2044
2347
2670
3014
3379
3765
4172

1042.39
1223.36
1418.81
1628.73
1853.14
2092.02
2345.38
2613.21
2895.53

31.6694
38.3200
45.6040
53.5213
62.0721

4.6354
5.6088
6.6749
7.8337
9.0853

3.2173
3.8929
4.6328
5.4372
6.3058

27,579
27,579
24,407
20,684
17,720

464
561
667
783
909

321.73
389.29
463.28
543.72
630.58

579
701
834
979
1136

402.16
486.61
579.11
679.64
788.23

695
841
1001
1175
1363

482.59
583.93
694.93
815.57
945.87

811
982
1168
1371
1590

563.02
681.25
810.75
951.50
1103.52

927
1122
1335
1567
1817

643.45
778.57
926.57
1087.43
1261.16

1043
1262
1502
1763
2044

723.88
875.90
1042.39
1223.36
1418.81

25.6522 3.7546 2.6060


31.6694 4.6354 3.2173
Kilowatts Required:

41,369
35,094

375
464

260.60
321.73

469
579

325.75
402.16

563
695

390.90
482.59

657
811

456.05
563.02

751
927

521.19
643.45

845
1043

586.34
723.88

630Q-8H
76
83
89
95
102
108
114
121
127

630Q-8V
64
70
76
83
89

630Q-8U
57
64

209

262

314

366

418

471

* Pumps applied above 400 HP and above 298 Kw. Require a lube oil heat exchanger. Volume is based on 100% volumetric efficiency. Brake horsepower is based on 90% mechanical efficiency.
For operstions below 75 RPM an auxiliary lubrication system is required.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Intermittent
Duty Pumps

Continue

Intermittent Duty Pumps

JWS-185

Triplex Intermittent Duty

"J" series intermittent duty pump


Rated input horsepower

NATIONAL-OILWELL Intermittent Duty


Pumps are appropriate for high-pressure,
high horsepower, operstions. This includes
applications such as reverse circulation,
well killing, acidizing, cementing, sand
fracturing and horizontal direction drilling.

Performance Data >

Field Connections in.


Pump Model
Discharge Connection Size
JWS-185

2-1/16" API-10,000# RTJ

Dimensions
Suction Connection Size
6" Std Pipe

Pump Type

Length

Width

Height

JWS-185

68-1/16"

51-7/8"

22-7/8

PUMP SPECIFICATIONS

Standard Equipment

Pump Size (Max. Plunger Diameter x Stroke) in. (mm)..................4 x 5 (102x127)


Rated BHP At 450 RPM (Kw) ...............................................................185 (137.9)
Maximum Working Pressure: PSI (kPa) ......................................10,000 (68,947.6)
Stroke Length, in. (mm) ................................................................................5 (127)
Maximum Speed, rpm........................................................................................450
Maximum Plunger size, in. (mm) ...............................................................4 (101.6)
Maximum Piston size, in. (mm) ...........................................................4-1/2 (114.3)

Forged Steel Fluid End


Forged Steel Valve Covers
Pistons & Liners
Or Plungers & Packing
Stainless Steel Extension Rods
Slush-Type Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Crankshaft Extension: in. (mm)


Diameter............................................................................................4-1/8 (104.78)
Length ...............................................................................................8-1/8 (206.38)
Keyway (Width x Depth) .........................................................1 x 1/2 (25.4 x 12.7)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter ...................................................................3 (76.2)
Length...........................................................6-3/16 (157.16)
Keyway (Width x Depth) .................3/4 x 3/8 (19.05 x 9.53)
Direct Drive: Diameter ...................................................................3 (76.2)
Length...........................................................6-3/16 (157.16)
Keyway (Width x Depth) ..................3/4 x 3/8 (19.05 x 9.53)

Oil Capacity: Gallons (L)


Crankcase ......................................................................................................8 (30)
Gear Unit (Varies with Ratio) .............................................2.25 to 3.5 (8.52:13.25)

Accessories
Bolt On Style Gear Reducers
3.22:1 Ratio
3.46:1 Ratio
4.38:1 Ratio
4.96:1 Ratio
Plunger Lubricator
Suction Stabilizer
Discharge Dampener
Liner Flush System
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Bearing Access
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) .................4,000 (1,814)
Gear Unit - Lbs. (Kg) ................................................................................800 (363)

JWS-185/6.99

< Return To Specs

JWS-185 Performance Data (Volumes Indicated are Displacement of Incompressible Fluid)


English Units
Plunger/
Piston*
Dia.
In.

25 RPM
Area
Inches
Squared

Gallon
Per
RPM

PSI

50 RPM

GPM

PSI

100 RPM

GPM

PSI

200 RPM

GPM

PSI

225 RPM

GPM

PSI

250 RPM

GPM

PSI

GPM

300 RPM
PSI

GPM

350 RPM
PSI

GPM

400 RPM
PSI

GPM

450 RPM
PSI

GPM

JWS-185
2
3.1416
0.2040 10,000 5.10
2 3/4
5.9396
0.3857 5,250 9.64
3 1/2
9.6212
0.6248 3,240 15.62
4
12.5664 0.8160 2,480 20.40
4 1/2
15.9044 1.03275 1,960 25.82
Brake Horsepower Required
33

10,000 10.20
5,250 19.28
3,240 31.24
2,480 40.80
1,960 51.64
66

10,000 20.40
5,250 38.57
3,240 62.48
2,480 81.60
1,960 103.28
132

7,000 40.80
3,700 77.14
2,280 124.95
1,750 163.20
1,380 206.55
185

6,220 45.90
3,290 86.78
2,030 140.57
1,550 183.60
1,230 232.37
185

5,600 51.00
2,960 96.42
1,830 156.19
1,400 204.00
n/a
n/a
185

4,660 61.20
2,470 115.71
1,520 187.43
1,170 244.80
n/a
n/a
185

4,000 71.40 3,500 81.60 3,110 91.80


2,110 134.99 1,850 154.28 1,644 173.56
1,310 218.66 1,140 249.90 1,020 281.14
1,000 285.60 870 326.40 780 367.20
n/a
n/a
n/a n/a
n/a
n/a
185
185
185

100 RPM

200 RPM

225 RPM

250 RPM

300 RPM

350 RPM

* 2" Available in Plunger Only.


** 4-1/2" Available with Piston Only.

Metric Units
Plunger/ Area
Piston* Centi- Liter
Dia.
meters Per
mm. Squared RPM

25 RPM
kPa

L/Min.

50 RPM
kPa

L/Min.

kPa

L/Min.

kPa

L/Min.

kPa

L/Min.

kPa

L/Min.

kPa

L/Min.

kPa

L/Min.

400 RPM
kPa

L/Min.

450 RPM
kPa

L/Min.

JWS-185
51
70
89
102
114

30.30 0.772
57.29 1.460
92.80 2.365
121.20 3.089
153.40 3.909
Kilowatts Required

68,950 19.30
36,199 36.50
22,340 59.12
17,100 77.21
13,514 97.72
25

68,950 38.61
36,199 72.99
22,340 118.23
17,100 154.43
13,514 195.45
49

68,950 77.21
36,199 145.98
22,340 236.47
17,100 308.86
13,514 390.90
98

48,265 154.43
25,512 291.97
15,721 472.94
12,066 617.71
9,515 781.79
138

42,887 173.73 38,612 193.04 32,131 231.64 27,580 270.25


22,685 328.46 20,409 364.96 17,031 437.95 14,548 510.94
13,997 532.05 12,618 591.17 10,480 709.40 9,032 827.64
10,687 694.93 9,653 772.14 8,067 926.57 6,895 1,081.00
8,481 879.52 n/a
n/a
n/a
n/a
n/a
n/a
138
138
138
138

24,133 308.86 21,443 347.46


12,756 583.93 11,335 656.92
7,860 945.87 7,033 1,064.11
5,999 1,235.42 5,378 1,389.85
n/a
n/a
n/a
n/a
138
138

* 51 mm Available in Piston Only.


** 114 mm Available with Piston Only.
Horsepower and Kilowatts required are based on 90% mechanical efficiency and 100% volumetric efficiency.

Intermittent Duty Ratings: These ratings are for intermittent service. Pressures as shown may be utilized for a period not to exceed
30 minutes followed by an equal period at no load, but not to exceed 4 hours in a 24 hour period.
Pressure Limitations, Caution: When pump is eqipped with pistons and liners, pressures in excess of 5,000 psi (34,475 kPa)
should not be exceeded except for emergencies or intermittent duty of short duration.
Speed Limitations: Speed in excess of 225 RPM is not recommended on JWS-185 pumps for maximum liner and piston life.
Charge Pump: A suction system charge pump is recommended for best operation. The charge pump should be capable of delivering
1-1/2 times the maximum discharge flow rate of the reciprocating pump.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

JWS-340

Triplex Intermittent Duty

"J" series intermittent duty pump


Rated input horsepower

NATIONAL-OILWELL intermittent duty


Pumps are appropriate for high-pressure,
high horsepower, operstions. This includes
applications such as reverse circulation,
well killing, acidizing, cementing, sand
fracturing and horizontal direction drilling.

Performance Data >

Field Connections in.


Pump Model Discharge Connection Size
JWS-340

2-1/16" API-10,000# RTJ

Dimensions
Suction Connection Size
6" Std Pipe

Pump Type

Length

Width

Height

JWS-340

68-1/16"

55-1/2"

22-7/8"

Pump Specifications

Standard Equipment

Pump Size (Max. Plunger Diameter x Stroke) in. (mm)..................4 x 5 (102x127)


Rated BHP At 450 RPM (Kw) ...............................................................340 (253.5)
Maximum Working Pressure: PSI (kPa) ......................................10,000 (68,947.6)
Stroke Length, in. (mm) ................................................................................5 (127)
Maximum Speed, rpm........................................................................................450
Maximum Plunger size, in. (mm) ...............................................................4 (101.6)
Maximum Piston size, in. (mm) ...........................................................4-1/2 (114.3)

Forged Steel Fluid End


Forged Steel Valve Covers
Pistons & Liners
Or Plungers & Packing
Stainless Steel Extension Rods
Slush-Type Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Crankshaft Extension: in. (mm)


Diameter..............................................................................................4-7/8 (123.8)
Length ...............................................................................................11-3/4 (298.0)
Keyway (Width x Depth).........................................................1-1/4 x 5/8 (32 x 16)
Pinion Shaft Extension, if gear unit supplied (mm)
Belt Or Chain Drive: Diameter .............................................................3-1/2 (88.9)
Length..................................................................5-3/4 (146)
Keyway (Width x Depth) .................7/8 x 7/16 (22.2 x 11.1)
Direct Drive: Diameter .............................................................3-1/2 (88.9)
Length..................................................................5-3/4 (146)
Keyway (Width x Depth) ..................7/8 x 7/16 (22.2 x 11.1)
Oil Capacity: Gallons (L)
Crankcase ......................................................................................................8 (30)
Gear Unit (Varies with Ratio).......................................3-1/2 to 6-1/2 (13.2 to 24.6)
Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg)..................5,200 (2,359)
Gear Unit - Lbs. (Kg) .............................................................................1,100 (499)

Accessories
Bolt On Style Gear Reducers
2.27:1 Ratio
2.89:1 Ratio
3.25:1 Ratio
4.38:1 Ratio
4.84:1 Ratio
Plunger Lubricator
Suction Stabilizer
Discharge Dampener
Liner Flush System
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Bearing Access
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

JWS-340/6.99

< Return To Specs

JWS-340 Performance Data (Volumes Indicated are Displacement of Incompressible Fluid)


English Units
Plunger/
Piston*
Area
Gallon
Dia.
Inches
Per
In.
Squared RPM

25 RPM
PSI

50 RPM

GPM

PSI

GPM

100 RPM
PSI

200 RPM

GPM

PSI

GPM

225 RPM
PSI

GPM

250 RPM
PSI

GPM

300 RPM
PSI

GPM

350 RPM
PSI

GPM

400 RPM
PSI

GPM

450 RPM
PSI

GPM

JWS-340
2 3/4
5.9396 0.3857
3 1/2
9.6212 0.6248
4
12.5664 0.8160
4 1/2
15.9044 1.03275
Brake Horsepower Required

10,000
6,220
4,760
3,760

9.64 10,000 19.28 10,000 38.57


15.62 6,220 31.24 6,220 62.48
20.40 4,760 40.80 4,760 81.60
25.82 3,760 51.64 3,760 103.28
63
126
252

6,800 77.14
4,200 124.95
3,210 163.20
2,540 206.55
340

6,040 86.78 5,440 96.42 4,530 115.71 3,890 134.99 3,400 154.28 3,020 173.56
3,730 140.57 3,360 156.19 2,800 187.43 2,400 218.66 2,100 249.90 1,870 281.14
2,860 183.60 2,570 204.00 2,140 244.80 1,840 285.60 1,610 326.40 1,430 367.20
2,260 232.37 n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
340
340
340
340
340
340

* 4-1/2" Available with Piston Only.

Metric Units
Plunger/
Piston*
Dia.
mm.

Area
CentiLiter
meters Per
Squared RPM

25 RPM
kPa

L/Min.

68,950
42,887
32,820
25,925

36.50
59.12
77.21
97.72

50 RPM
kPa

L/Min.

100 RPM
kPa

L/Min.

200 RPM
kPa

L/Min.

225 RPM
kPa

L/Min.

250 RPM
kPa

L/Min.

300 RPM
kPa

L/Min.

350 RPM
kPa

L/Min.

400 RPM
kPa

L/Min.

450 RPM
kPa

L/Min.

JWS-340
70
57.29
89
92.80
102
121.20
114
153.40
Kilowatts Required

1.460
2.365
3.089
3.909

47

68,950 72.99 68,950 145.98


42,887 118.23 42,887 236.47
32,820 154.43 32,820 308.86
25,925 195.45 25,925 390.90
94
188

46,886 291.97
28,959 472.94
22,133 617.71
17,513 781.79
254

41,646 328.46 37,509 364.96 31,234 437.95 26,822 510.94 23,443 583.93 20,823 656.92
25,718 532.05 23,167 591.17 19,306 709.40 116,548 827.64 14,480 945.87 12,894 1,064.11
19,720 694.93 17,720 772.14 14,755 926.57 12,687 1,081.00 11,101 1,235.42 9,860 1,389.85
15,583 879.52 n/a
n/a
n/a
n/a
n/a
n/a
n/a n/a
n/a
n/a
254
254
254
254
254
254

* 114 mm Available with Piston Only.


** Horsepower and Kilowatts required are based on 90% mechanical efficiency and 100% volumetric efficiency.

Intermittent Duty Ratings: These ratings are for intermittent service. Pressures as shown may be utilized for a period not to exceed
30 minutes followed by an equal period at no load, but not to exceed 4 hours in a 24 hour period.
Pressure Limitations, Caution: When pump is eqipped with pistons and liners, pressures in excess of 5,000 psi (34,475 kPa)
should not be exceeded except for emergencies or intermittent duty of short duration.
Speed Limitations: Speed in excess of 225 RPM is not recommended on JWS-340 pumps for maximum liner and piston life.
Charge Pump: A suction system charge pump is recommended for best operation. The charge pump should be capable of delivering
1-1/2 times the maximum discharge flow rate of the reciprocating pump.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Triplex Intermittent Duty

JWS-400

"J" series intermittent duty pump


Rated input horsepower

NATIONAL-OILWELL Well Service Pumps


are appropriate for high-pressure, high
horsepower, intermittent duty operations.
This includes applications such as reverse
circulation, well killing, acidizing, cementing,
and sand fracturing.

Performance Data >

Dimensions

Field Connections in.


Pump Model
Discharge Connection Size Suction Connection Size
JWS-400

3-1/16" API-6 BX 10,000 PSI

6" ASA 150# R.F.

Pump Specifications
Pump Size (Max. Liner Diameter x Stroke) in. (mm)........5-1/2 x 7 (139.7 x 177.8)
Pump Size (Max. Plunger Diameter x Stroke) in. (mm) ...4-1/2 x 7 (114.3 x 177.8)
Rated BHP At 450 RPM (Kw) ..................................................................400 (298)
Maximum Working Pressure: PSI (kPa) ......................................10,000 (68,947.6)
Stroke Length, in. (mm) .............................................................................7 (177.8)
Maximum Speed, rpm........................................................................................286
Maximum Plunger size, in. (mm).........................................................4-1/2 (114.3)
Maximum Piston size, in. (mm) ...........................................................5-1/2 (139.7)

Pump Type

Length

Width

Height

JWS-400

96-7/16"

95-1/2"

49-1/2"

Standard Equipment
Forged Steel Fluid End
Forged Steel Valve Covers
Pistons & Liners
Or Plungers & Packing
Stainless Steel Extension Rods
Slush-Type Valves
Double Extended Crankshaft
Oil Level Dipstick
Crankcase Breather

Accessories
Crankshaft Extension: in. (mm)
Diameter ....................................................................................................6 (152.4)
Length ...............................................................................................10-1/4 (260.4)
Keyway (Width x Depth).................................................1-1/2 x 3/4 (38.1 x 19.05)
Pinion Shaft Extension, if chain drive supplied (mm)
Diameter..............................................................................................3-3/4 (95.25)
Length........................................................................................................6 (152.4)
Keyway (Width x Depth) ....................................................7/8 x 7/16 (22.2 x 11.1)

Oil Capacity: Gallons (L)


Crankcase .................................................................................................22 (83.3)
Gear Unit .................................................................................................30 (113.5)

Chain Reducer (4.667:1)


Plunger Lubricator
Suction Stabilizer
Discharge Dampener
Liner Flush System
Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features

Horizontal Design
Large Power End Covers
Easy Bearing Access
Separate Crosshead/Plunger Construction
Open Frame Construction
Removable Stuffing Boxes

Weight: Pump Only On Wood Shipping Skids - Lbs. (Kg) ...............15,000 (6,804)

JWS-400/6.99

< Return To Specs

JWS-400 Performance Data (Volumes Indicated are Displacement of Incompressible Fluid)


English Units
Plunger/
Piston*
Dia.In.

Area
Inches
Squared

Gallon
Per
RPM

25 RPM
PSI

55 RPM

GPM

PSI

75 RPM

GPM

PSI

100 RPM

GPM

PSI

140 RPM

GPM

PSI

175 RPM

GPM

PSI

200 RPM

250 RPM

286 RPM

GPM

PSI

GPM

PSI

GPM

PSI

GPM

3,100 199.92
2,435 253.02
1,979 312.38
1,795 344.39
1,635 377.97
400

2,725
2,140
1,741
1,579
1,439

228.48
289.17
357.00
393.59
431.97
400

2,175
1,715
1,390
1,261
1,149

285.60
361.46
446.25
491.99
539.96
400

1,900
1,500
1,217
1,102
1,004

326.73
413.51
510.51
562.84
617.72
400

175 RPM

200 RPM

JWS-400
4
12.5664 1.1424 10,000 28.56
4 1/2
15.9044 1.4459 8,000 36.15
5
19.6350 1.7850 6,400 44.63
5 1/4
21.6476 1.9680 5,804 49.20
5 1/2
23.7584 2.1599 5,289 54.00
Brake Horsepower Required
187

10,000 62.83
8,000 79.52
6,334 98.18
5,747 108.24
5,216 118.79
400

7,250 85.68
5,747 108.44
4,636 133.88
4,205 147.60
3,831 161.99
400

5,445 114.24
4,280 144.59
3,482 178.50
3,159 196.80
2,878 215.99
400

3,819 159.94
3,072 202.42
2,483 249.90
2,249 275.51
2,055 302.38
400

* 5", 5-1/2", and 5-1/2" Available with Piston Only.

Metric Units
Plunger/ Area
Piston* Centi- Liter
Dia. meters Per
mm. Squared RPM

25 RPM
kPa

L/Min.

55 RPM
kPa

L/Min.

75 RPM
kPa

L/Min.

100 RPM
kPa

L/Min.

140 RPM
kPa

L/Min.

kPa

L/Min.

kPa

L/Min.

250 RPM
kPa

L/Min.

286 RPM
kPa

L/Min.

JWS-400
102
114
127
133
140

121.20 4.324
153.40 5.473
189.38 6.756
208.79 7.449
229.15 8.175
Kilowatts Required

68,950 108.10
55,160 136.81
44,128 168.91
40,019 186.22
36,468 204.38
140

68,950 237.82
55,160 300.99
43,673 371.59
39,626 409.68
35,964 449.63
298

49,989 324.30
39,626 410.44
31,965 506.72
28,993 558.66
26,415 613.13
298

37,543 432.40
29,511 547.25
24,008 675.62
21,781 744.87
19,844 817.50
298

26,332 605.36
21,181 766.16
17,120 945.87
15,507 1,042.82
14,169 1,144.50
298

21,375 756.70
16,789 957.69
13,645 1,182.34
12,377 1,303.53
11,273 1,430.63
298

18,789 864.80
14,755 1,094.51
12,004 1,351.25
10,887 1,489.75
9,922 1,635.01
298

14,997 1,081.00
11,825 1,368.14
9,584 1,689.06
8,695 1,862.18
7,922 2,043.76
298

13,101 1,236.66
10,343 1,565.15
8,391 1,932.28
7,598 2,130.34
6,923 2,338.06
298

* 127 mm, 133 mm, and 140 mm Available with Piston Only.
** Horsepower and Kilowatts required are based on 90% mechanical efficiency and 100% volumetric efficiency.

Intermittent Duty Ratings: These ratings are for intermittent service. Pressures as shown may be utilized for a period not to exceed
30 minutes followed by an equal period at no load, but not to exceed 4 hours in a 24 hour period.
Pressure Limitations, Caution: When pump is equipped with pistons and liners, pressures in excess of 5,000 psi (34,475 kPa)
should not be exceeded except for emergencies or intermittent duty of short duration.
Speed Limitations: Speed in excess of 175 RPM is not recommended on JWS-400 pumps for maximum liner and piston life.
Charge Pump: A suction system charge pump is recommended for best operation. The charge pump should be capable of delivering
1-1/2 times the maximum discharge flow rate of the reciprocating pump.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Series

Triplex Intermittent Duty

SA-600-5

"SA" series intermittent duty pump


Rated input horsepower
Stroke length (in.)

The SA-pump series incorporates the desirable


combination of light weight and high strength, ideal for
mounting onto truck/trailer, barge and platform while
providing dependable intermittent duty service.
Performance Data >

Field Connections in. (mm)


Pump Model
Discharge Connection Size

Dimensions
Suction Connection Size

Pump Type

Length

Width

Height

SA-626-5

2" Fig 1502 Female Union Half

4" Grooved Std Pipe

SA-626-5

87-9/16"

43-9/16"

42-3/4"

SA-630-5

2" Fig 1502 Female Union Half

4" Grooved Std Pipe

SA-630-5

87-9/16"

43-9/16"

42-3/4"

SA-634-5

2" Fig 1502 Female Union Half

4" Grooved Std Pipe

SA-634-5

74-3/8"

44-9/16"

42-3/4"

SA-640-5

2" Fig 1502 Female Union Half

4" Grooved Std Pipe

SA-640-5

74-3/8"

44-9/16"

42-3/4"

SA-644-5

3" Fig 1002 Female Union Half

5" Grooved Std Pipe

SA-644-5

77-1/8"

42-1/8"

42-3/4"

SA-650-5

3" Fig 1002 Female Union Half

5" Grooved Std Pipe

SA-650-5

77-1/8"

42-1/8"

42-3/4"

Pump Specifications
Pump Size (Max. Plunger Diameter x Stroke)
SA-626-5 ...........2-3/4 x 6 (70x152)
SA-630-5..................3 x 6 (76x152)
SA-634-5 ...........3-1/2 x 6 (89x152)

Standard Equipment
in. (mm)
SA-640-5 .............4 x 6 (102x152)
SA-644-5 .......4-1/2 x 6 (114x152)
SA-650-5 .............5 x 6 (127x152)

Rated BHP At 450 RPM (Kw)...................................................................500 (373)


Maximum Working Pressure: PSI (kPa) ...................................see table on back
Discharge:
SA-626-5 .............15,000 (103,421)
SA-630-5 ...............13,000 (89,632)
SA-634-5 .................1,000 (68,948)

SA-640-5...............8,000 (55,158)
SA-644-5...............6,000 (41,369)
SA-650-5...............5,000 (34,474)

Suction:
SA-626-5 ......................500 (3,447)
SA-630-5 ......................500 (3,447)
SA-634-5 ......................500 (3,447)

SA-640-5....................500 (3,447)
SA-644-5....................150 (1,034)
SA-650-5....................500 (3,447)

Stroke Length, in. (mm) ...............6 (152)


Maximum Speed, rpm........................................................................................450
Maximum Plunger size, in. (mm)
SA-626-5 .........................2-3/4 (70)
SA-640-5...........................4 (102)
SA-630-5 ...............................3 (76)
SA-644-5.....................4-1/2 (114)
SA-634-5 .........................3-1/2 (89)
SA-650-5...........................5 (127)
Oil Capacity: Gallons (L)
Crankcase................................................................................................Dry Sump
Weight: Pump Only On Wood Shipping Skids
SA-626-5 ...................5,300 (2,404)
SA-630-5 ...................5,750 (2,608)
SA-634-5 ...................5,400 (2,449)

- Lbs. (Kg)
SA-640-5.................5,463 (2,477)
SA-644-5.................6,160 (2,794)
SA-650-5.................6,236 (2,829)

Forged Steel Fluid End


Fabricated Steel Suction Manifold
Forged Steel Discharge Connection
Threaded Packing Glands
Tungsten Carbide Coated Plungers
Pressure Actuated Header Ring Packing
"Mission" Service Master Valves
Urethane Valve Discs
Alloy Steel Valve Seats

Accessories
Bolt On Style Gear Reducers
4.77:1 Standard Ratio
5.45:1 Optional Ratio
Oil Pressure Gauge
Bronze Latern Rings
Bronze Packing Followers
Crankcase Breather
Rockide Plungers
Tach Drive Connection
Thermometer
Plunger Lubricator
Relief Valves
Valve Service Kit
Center Gauge Connection
Complete Unitization Services

Quick Maintenance Features


Horizontal Design
Built-in Bearing Clearance
Large Power End Access Covers
Replaceable Gear Unit
Tapered Roller Bearings

SA-600-5/6.99

< Return To Specs

SA-600 Series Performance Data (Volumes Indicated Are Displacement Of Incompressible Fluid)
English Units
Plunger Area Gallon
Dia.
Inches
Per
Inches Squared RPM

100 RPM
PSI

GPM

150 RPM
PSI

200 RPM

GPM

PSI

250 RPM

300 RPM

GPM

PSI

350 RPM

GPM

PSI

GPM

400 RPM
PSI

GPM

450 RPM

GPM

PSI

PSI

GPM

92.57

7,406

115.71
500

6,173

138.85
500

5,290

161.99
500

4,630 185.13
500

4,116

208.27
500

SA-626-5
2 3/4
5.94
0.463 15,000 46.28
Brake Horsepower Required:
405

12,345 69.42
500

9,260

10,373 82.62
500

7,780

110.16
500

6,224

137.70
500

5,186

165.24
500

4,446

192.78
500

3,890 220.32
500

3,458

247.86
500

7,621

112.46
500

5,716

149.94
500

4,573

187.43
500

3,810

224.91
500

3,266

262.40
500

2,858 299.88
500

2,540

337.37
500

5,834

146.88
500

4,377

195.84
500

3,500

244.80
500

2,918

293.76
500

2,500

342.72
500

2,188 391.68
500

1,945

440.64
500

4,610

185.90
500

3,458

247.86
500

2,766

309.83
500

2,305

371.79
500

1,976

433.76
500

1,729 495.72
500

1,537

557.69
500

3,734

229.50
500

2,800

306.00
500

2,241

382.50
500

1,867

459.00
500

1,600

535.50
500

1,400 612.00
500

1,245

688.50
500

500

SA-630-5
3
7.0686 0.5508 13,000 55.08
Brake Horsepower Required:
437

SA-634-5
3 1/2
9.62
0.75 10,000 74.97
Brake Horsepower Required:
437

SA-640-5
4
12.5664 0.9792 8,000
97.92
Brake Horsepower Required:
457

SA-644-5
4 1/2 15.9044 1.2393 6,000 123.93
Brake Horsepower Required:
434

SA-650-5
5
19.6350 1.5300 5,000 153.00
Brake Horsepower Required:
446

Metric Units
Plunger Area
Diameter Centi.
mm. Squared

Liter
Per
RPM

100 RPM
kPa

L/Min.

150 RPM
kPa

200 RPM

L/Min.

kPa

L/Min.

250 RPM
kPa

300 RPM

L/Min.

kPa

350 RPM

L/Min.

kPa

L/Min.

400 RPM
kPa

L/Min.

450 RPM
kPa

L/Min.

SA-626-5
70
38.32 1.752
Kilowatts Required:

103,425 175.18 85,119 262.77 63,848 350.36 51,064 437.95


302
373
373
373

42,563 525.54 36,475 613.13 31,924 700.72 28,380 788.31


373
373
373
373

89,635 208.48
326

71,522 312.72 53,643 416.96


373
373

42,914 521.19
373

35,757 625.43
373

30,655 729.67
373

26,822 833.91
373

68,950 283.76
326

52,547 425.64 39,412 567.52


373
373

31,531 709.40
373

26,270 851.28
373

22,519 993.17
373

19,706 1,135.05 17,513 1,276.93


373
373

55,160 370.63
341

40,225 555.94 30,179 741.25


373
373

24,133 926.57
373

20,120 1,111.88 17,238 1,297.20 15,086 1,482.51 13,411 1,667.82


373
373
373
373

41,370 469.08
324

31,786 703.61 23,843 938.15


373
373

19,072 1,172.69 15,893 1,407.23 13,625 1,641.76 11,921 1,876.30 10,598 2,110.84
373
373
373
373
373

SA-630-5
76
45.60 2.085
Kilowatts Required:

23,843 938.15
373

SA-634-5
89
62.07
2.84
Kilowatts Required:

SA-640-5
102
81.07 3.706
Kilowatts Required:

SA-644-5
114
102.61 4.691
Kilowatts Required:

SA-650-5
127
126.68 5.791
Kilowatts Required:

34,475 579.11 25,746 868.66 19,306 1,158.21 15,452 1,447.76 12,873 1,737.32 11,032 2,026.87 9,653 2,316.42 8,584 2,605.97
333
373
373
373
373
373
373
373

** Horsepower and Kilowatts required are based on 90% mechanical efficiency and 100% volumetric efficiency.
Intermittent Duty Ratings: These ratings are for intermittent service. Pressures as shown may be utilized for a period not to exceed
30 minutes followed by an equal period at no load, but not to exceed 3 hours in a 24 hour period.
Pressure Limitations, Caution: When pump is equipped with pistons and liners, pressures in excess of 5,000 psi (34,475 kPa)
should not be exceeded except for emergencies or intermittent duty of short duration.
Charge Pump: A suction system charge pump is recommended for best operation. The charge pump should be capable of delivering
1-1/2 time the maximum discharge flow rate of the reciprocationg pump.

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King Fluid
End replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general
information only. Applications suggested for the materials and
other information are described only to help readers make
their own evaluations and decisions, and are neither
guarantees nor are they to be construed as express or
implied warranties of suitability for these or other applications.
National Oilwell makes no warranty, either express or implied,
beyond that stipulated in National Oilwells Standard Terms
and Conditions of Sale which are available upon request.

6K500

Triplex Intermittent Duty

NATIONAL-OILWELL Intermittent Duty


Pumps are appropriate for high-pressure,
high horsepower, operations. This includes
applications such as reverse circulation, well
killing, acidizing, cementing, sand fracturing,
and horizontal directional drilling.

Performance Data >

Dimensions

Field Connections in. (mm)


Discharge Connection Size

Suction Connection Size

Length

Width

Height

2" Fig. 1502 Female Union Half

6" Grooved Standard Pipe

78"

51"

35"

Pump Specifications:
Pump Size:
(Max. Plunger Diameter X Stroke) in. (mm) ......................4.5" X 6" (114.3 X 152)
Rated BHP (KW) At 450 RPM..................................................................555 (388)
Stroke Length in. (mm) ...............................................................................6" (152)
Oil Capacity: Gallons (L)
Crankcase................................................................................................Dry Sump
Maximum Working Pressure:
With 3 1/2" Plungers PSI (kPa) ..............................................10,000 (66.808)
With 4" Plungers PSI (kPa) ....................................................10,000 (66.808)
With 4 1/2" Plungers PSI (kPa) ................................................6,000 (41.369)
Weight: Dry Pounds. (Kg)................................................................6,090 (30,177)

Standard Equipment
Pressure Lubricated Power End
Forged Steel Fluid End
Colmonoy Coated Plungers
Adjustable Lip Type Packing
Wing Guided Style Valves
Replaceable Resilient Valve Insert
Alloy Steel Valve Seats

Accessories
Bolt on Style Gear Reducer
5.28:1 Standard Ratio
4.77:1 Optional Ratio
Packing Lubricator
Oil Pressure Gauge
Tachometer Drive Connection
Alternate Plunger Materials
Valve Service Kit
Relief Valve
Complete Pump Unitization

6K500-6/6.99

Intermittent Service - 6K500 Stroke Triplex Pump

< Return To Specs

English Units
Plunger Plgr.Area Max
Size Sq. In. Pressure
3 1/2

4 1/2

GPM/
RPM

100 RPM
PSI BPM

150 RPM
PSI
BPM

200 RPM
PSI
BPM

250 RPM
PSI
BPM

300 RPM
PSI
BPM

350 RPM
PSI
BPM

400 RPM
PSI
BPM

450 RPM
PSI
BPM

9.621
10000 0.7497 10000 1.785
Brake Input Horsepower
485

7621 2.678
555

5716

4573

4.463
555

3810

3266 6.248
555

2858

2540

555

12.566 10000 0.9792 10000 2.331


Brake Input Horsepower
507

5834

4377

5.829
555

2918 6.994
555

2500 8.160
555

2188

15.904
6000
1.2393 6000 2.951
Brake Input Horsepower
482

4610

7.377
555

2305 8.852
555

1976 10.328
555

1729

300 RPM

350 RPM

3.497
555
4.426

3.570
555

3458

555

4.663
555

3500

5.901
555

2766

5.355

7.140
555

8.033
555

9.326

1945

10.491
555

11.803
555

1537

13.278
555

555

* Ratings are for intermittent service. Operations at maximum conditions should not exceed 3 hours per day

Metric Units
Plunger Plunger
Dia.
Area
mm Sq. cm.

Max. L/Min.
Press. Per
kPa
RPM

100 RPM
kPa

L/Min.

150 RPM
kPa

L/Min.

200 RPM
kPa

L/Min.

250 RPM
kPa

L/Min.

kPa

L/Min.

26,269 993.0
414

kPa

L/Min.

400 RPM
kPa

L/Min.

450 RPM
kPa.

L/Min.

89

62.08 68,948 3.31


Kilowatts Required

68,948 331.0
362

52,545 496.5
414

39,410 662.0
414

31,530 827.5
414

22,518 1158.5 19,705 1324.0 17,513 1489.5


414
414
414

102

81.08 68,948 4.32


Kilowatts Required

68,948 432.0
378

40,224 648.0
414

30,178 864.0
414

24,132 1080.0 20,119 1296.0 17,237 1512.0 15,086 1728.0 13,410 1944.0
414
414
414
414
414

114

102.61 41,369 5.47


Kilowatts Required

41,369 547.0
359

31,785 820.5
414

23,842 1094.0 19,071 1367.5 15,892 1641.0 13,624 1914.5 11,921 2188.0 10,597 2461.5
414
414
414
414
414
414

* Ratings are for intermittent service. Operations at maximum conditions should not exceed 3 hours per day

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general
information only. Applications suggested for the materials and
other information are described only to help readers make
their own evaluations and decisions, and are neither
guarantees nor are they to be construed as express or
implied warranties of suitability for these or other applications.
National Oilwell makes no warranty, either express or implied,
beyond that stipulated in National Oilwells Standard Terms
and Conditions of Sale which are available upon request.

Double Acting
Duplex Pumps

Continue

Double Acting Duplex Pumps

612-P

Duplex Piston Pump


Max liner bore in inches

Stroke length (in.)


Piston style pump

This NOI Duplex Pump provides


superior service for most crude oil
pipeline pumping applications.

Performance Data >

Field Connections in. (mm)


Discharge Connection Size
4" ANSI-400 FNPT

Dimensions Pump w/ Sub-Base


Suction Connection Size

Length

Width

Height

6" ANSI-300 FNPT

11' - 1 1/2"

4' - 10 1/8"

3'- 10.0"

Pump Specifications:

Standard Equipment

Pump Size (Piston Diameter x Stroke) in. (mm)....................6 x12 (152.4 x 304.8)
Gear Ratio....................................................................................................5.06 : 1
Rated BHP At 70 RPM (kw) ..................................................................140 (104.4)
Rated Rod Load, pounds (Kg) .........................................................15,021 (6,676)

Cast Iron Fluid End


Chrome Iron Liners
Chrome Plated Piston Rods
Slush Type Valve
Replaceable Urethane Valve Discs
Alloy Steel Valve Seats

Maximum Working Pressure: PSI (kPa) ..........................................765 (5,270.9)

Accessories

Pinion Shaft Extension: in. (mm)


Diameter .............................................................................................3.628 (92.15)
Length.........................................................................................................10 (254)
Keyway (Width x Depth) ...................................................7/8 x 5/16 (22.23 x 7.94)
Oil Capacity: Gallons (L)
Crankcase: ..............................................................................................16 (60.57)

Relief Valves
Valve Service Kit
Complete Unitization Services

Quick Maintenance Features


Horizontal Design
Built-in Bearing Clearance
Large Power End Access Covers
Replaceable Gear Unit
Tapered Roller Bearings

Weight: Pump Mounted on Sub-Base: ........................................10,290 (4667.46)

612-P/6.99

< Return To Specs

612-P Performance Data (Volumes Indicated are Displacement of Incompressible Fluid)


English Units
Piston
Size in.

Maximum
Working
Pressure PSI

Displacement
Gallons per rev.

Pump Speed
30 RPM

Pump Speed
40 RPM

Pump Speed
50 RPM

Pump Speed
60 RPM

Pump Speed
70 RPM

3.79
4.65
5.60

115
140
170
60

150
185
225
80

190
230
280
100

225
280
335
120

265
325
390
140

612-P
5"
5 1/2"
6"

765
625
520
Brake Horsepower Required

Metric Units
Piston
Size (mm)

Maximum
Working
Pressure kPa

Displacement
Leters per rev.

Pump Speed
30 RPM

Pump Speed
40 RPM

Pump Speed
50 RPM

Pump Speed
60 RPM

Pump Speed
70 RPM

14.35
17.60
21.20

2921
3556
4318
1524

3810
4699
5715
2032

4826
5842
7112
2540

5715
7112
8509
3048

6731
8255
9906
3556

612-P
127
139.7
152.4

5274.52
4309.25
3585.30
Kilowatts Required

Sales/Technical Information:
USA Tollfree: 1 (800) 800-4110
Internet:

www.natoil.com

National Oilwell is a leading manufacturer


of reciprocating plunger pumps, Mission
centrifugal pumps, and Fluid King fluid
end replacement parts. We also offer a
complete set of solutions to your fluid
transfer challenges.
For more information, contact National
Oilwell directly at the Headquarters in
Houston, Texas. All National Oilwell
products are available throughout the U.S.
and around the world from service centers,
authorized distributors, and representatives.

Copyright 1999 by National Oilwell, L.P. All Rights


Reserved. NATIONAL OILWELL, NATIONAL, and OILWELL
are registered trademarks of NATIONAL OILWELL, L.P.
Houston, Texas, USA. All other trademarks used are
registered to their respective companies. The information and
data in this brochure, including but not limited to pictures,
photographs, charts, diagrams, drawings, lists, written
comments, and specifications, are accurate to the best of our
knowledge and belief, but are intended for general information
only. Applications suggested for the materials and other
information are described only to help readers make their
own evaluations and decisions, and are neither guarantees
nor are they to be construed as express or implied warranties
of suitability for these or other applications. National Oilwell
makes no warranty, either express or implied, beyond that
stipulated in National Oilwells Standard Terms and
Conditions of Sale which are available upon request.

Вам также может понравиться