HOUSINGS AND ACCESSORY PRODUCTS

Orifice Disc Installation & Sizing Guide


FLOW-LIMITING ORIFICE DISCS
Standard HydraForce cavity forming tools enable the designer to make convenient use of flow-limiting orifice discs, installed immediately under the cartridge when pilot drill diameters shown on housing details, or smaller, are used.

Disc Dia.
Drill Thru Dia.

Flow

CBore Depth
CBore Dia.
Pilot Drill
Dia. (Max.)

Orifice Discs 5000 PSID Max.


Orifice Disc
Part No.*

Disc Dia.
(Max.)

Pilot Drill
Dia. (Max.)

Counterbore Dia./
Counterbore Depth

7051_ _ _

None

None

for cavities:

.015 to .062

.125 Dia./.074 Dp.

.063 to .109

.2187 Dia./.050 Dp.

.110 & Up

None

VC08-2
VC08-4

.500

.437

7057_ _ _
for cavitiy:

.562

.500

VC08-3

None

None

.015 to .062

.125 Dia./.074 Dp.

.063 to .109

.2187 Dia./.050 Dp.

.110 & Up

None

7063_ _ _

None

None

for cavities:

.015 to .062

.125 Dia./.074 Dp.

.063 to .109

.2187 Dia./.050 Dp.

.110 & Up

None

VC10-2
VC10-3
VC10-4

.625

.562

7087_ _ _
for cavities:

VC12-2
VC12-3

.872

.781

7081_ _ _
for cavity:

.810

.718

VC12-4

*Last 3 digits determined by drill-thru diameter.

8.460.1

Drill-Thru Dia.

None

None

.015

.125 Dia./.084 Dp.

.016 to .062

.125 Dia./.084 Dp.

.063 to .109

.2197 Dia./.060 Dp.

.110 & Up

None

None

None

.015

.125 Dia./.084 Dp.

.016 to .062

.125 Dia./.084 Dp.

.063 to .109

.2197 Dia./.060 Dp.

.110 & Up

None
All dimensions shown in inches.

HYDRAFORCE.com

Blue rectangles are links to other catalog pages.

HYDRAFORCE

Orice Disc Installation & Sizing Guide

(contd)

TYPICAL INSTALLATIONS
See specific product pages to determine if orifice disc can be used with a particular valve.

Caution: Spool extension below the


valve cage prohibits orifice disc use.

ORDERING INFORMATION
See Orifice Sizing Guide charts on pages 8.460.3 and 8.460.4 for information necessary to specify Drill-Thru Diameter.

70__ __ __ __ __

Disc Dia.
.500 in.
.562 in.
.625 in.
.810 in.
.875 in.

HYDRAFORCE.com

51
57
63
81
87

Drill-Thru Diameter
Specify in thousandths of an inch, i.e.
000 Blank
031 .031 in. Drill-Thru Diameter

8.460.2

HOUSINGS AND ACCESSORY PRODUCTS

Orifice Disc Sizing Guides


ORIFICE DISC SIZING GUIDE (Inches)
Curves represent orifice disc drill-thru diameters.

.1
70

.1 8

95/25

.19

0
.20

98/26

.21
0

102/27

.22
0

.240
.23
0

.280
.270
.260
.250

.320

.350

.300

106/28

.400

.600

110/29

.500

114/30

.1
60

91/24
87/23

.1

50

83/22
79/21

.1

40

76/20
72/19

30

.1

FLOW - LPM/GPM

68/18
64/17

.12

61/16
57/15

.11

53/14
49/13

.10

45/12
42/11
38/10

.090

34/9
30/8

.080

26/7
.070

23/6
19/5

.060

15/4
11/3

.050

8/2

.040

4/1

.030
.020
.010
172.4
206.9
2500
3000

0.7 1.4
10 20

3.4 5.2 6.9 10.3 13.8


50 75 100 150 200

20.7
300

27.6 34.5 41.4 48.3 55.2 62.1 69.0


400 500 600 700 800 900 1000

103.4
1500

137.9
2000

P BAR/PSI
Note: Table is calculated at 32 cSt (150 SSU) oil at 40C. Values will change with viscosity changes.

8.460.3

HYDRAFORCE.com

HYDRAFORCE

Orifice Disc Sizing Guides

(contd)

ORIFICE DISC SIZING GUIDE (mm)


Curves represent orifice disc drill-thru diameters.

4.9

5.4

5.1

98/26

5.6

102/27

5.9

7.2
6.8
6.6
6.4
6.1

8.2

7.7

106/28

8.9

10.2

15.4

110/29

12.8

114/30

4.
4

4.6

95/25
91/24

4.
1

87/23

3.

83/22
79/21

3.

76/20
72/19

3.

FLOW - LPM/GPM

68/18
64/17

3.0

61/16
57/15

2.8

53/14
49/13

2.5

45/12
42/11
38/10

2.3

34/9
30/8

2.0

26/7
1.8

23/6
19/5

1.5

15/4
11/3

1.3

8/2

1.0

4/1

.75
.50
.35

0.7 1.4
10 20

3.4 5.2 6.9 10.3 13.8


50 75 100 150 200

20.7
300

27.6 34.5 41.4 48.3 55.2 62.1 69.0


400 500 600 700 800 900 1000

103.4
1500

137.9
2000

172.4
2500

206.9
3000

P BAR/PSI
Note: Table is calculated at 32 cSt (150 SSU) oil at 40C. Values will change with viscosity changes.

HYDRAFORCE.com

8.460.4