Вы находитесь на странице: 1из 2

home

courses

engineeringguides

LoadFlow

OvercurrentCoordination

ShortCircuit

EquipmentSizing

MotorStarting

EquipmentProtection

ProtectiveDeviceSelection

LifeSafety

ArcFlashHazard

SystemReliability

references

links

registration

contactus

EssentialReferencesforEngineersPerformingPower
SystemStudies
RecommendedforBreakerRatingsandtheANSISC
CalculationMethod
IEEEStdC37.0101999,IEEEApplicationGuide
forACHighVoltageCircuitBreakersRatedona
SymmetricalCurrentBasis
RecommendedforCoordinationStudies

Headlinesasof:January19,2017

2006CourseScheduleReleased.Coursesare set for Round


RockinMarch,OrlandoinMay,DenverinAugustandHouston
inOctober.
JanuaryAnalyzerAvailableforDownload.Thismonthstopic,
TheABCsofOvercurrentCoordination.

IEEEStdC37.912000,IEEEGuidefor
ProtectiveRelayApplicationstoPower
Transformers
IEEEStdC37.952002,IEEEGuidefor
ProtectiveRelayingofUtilityCustomer
Interconnections
IEEEStdC37.962000,IEEEGuideforACMotor
Protection
IEEEStdC37.912000,IEEEGuidefor
ProtectiveRelayApplicationstoPowerSystem
Buses
IEEEStdC37.992000,IEEEGuideforthe
ProtectionofShuntCapacitorBanks
IEEEStdC37.1011983,IEEEGuidefor
GeneratorGroundProtection
IEEEStdC37.1021995,IEEEGuideforAC
GeneratorProtection
IEEEStdC37.1082002,IEEEGuideforthe
ProtectionofNetworkTransformers
IEEEStdC37.1091988,IEEEGuideforthe
ProtectionofShuntReactors
IEEEStdC37.1101996,IEEEGuideforthe
ApplicationofCurrentTransformersUsedfor
ProtectiveRelayingPurposes
IEEEStdC37.1121996,IEEEStandardInverse
TimeCharacteristicEquationsforOvercurrent
Relays
IEEEStdC37.1131999,IEEEGuidefor
ProtectiveRelayApplicationstoTransmission
Lines
IEEEStdC57.12.592001,IEEEGuideforDry
TypeTransformerThroughFaultCurrent
Duration
IEEEStdC57.1091993,IEEEGuideforLiquid
ImmersedTransformerThroughFaultCurrent
Duration
IEEEStd6201996,IEEEGuideforthe
PresentationofThermalLimitCurvesforSquirrel
CageInductionMachines
RecommendedforEquipmentSelection
UL67January12,2000,Panelboards
UL489March22,2000,MoldedCaseCircuit
Breakers,MoldedCaseSwitches,andCircuit
BreakerEnclosures
UL845May17,2000,MotorControlCenters

UL891December23,1998,DeadFront
Switchboards
UL1066May30,1997,LowVoltageACand
DCPowerCircuitBreakersusedinEnclosures
UL1558February25,1999,MetalEnclosed
LowVoltagePowerCircuitBreakerSwitchgear
IEEEStd10151993,IEEERecommended
PracticeforApplyingLowVoltageCircuit
BreakersUsedinIndustrialandCommercial
PowerSystems(IEEEBlueBook)
RecommendedforArcFlashHazardStudies
IEEEStd15842002,IEEEGuideforPerforming
ArcFlashHazardCalculations
NFPA70E,StandardforElectricalSafetyinthe
Workplace,NationalFireProtectionAssociation,
Quincy,Massachusetts,2004
RecommendedasBasicEngineeringReferences
IEEEStd1411993,IEEERecommended
PracticeforElectricPowerDistributionfor
IndustrialPlants(IEEERedBook)
IEEEStd2422001,IEEERecommended
PracticeforProtectionandCoordinationof
IndustrialandCommercialPowerSystems(IEEE
BuffBook)
IEEEStd3991997,IEEERecommended
PracticeforIndustrialandCommercialPower
SystemsAnalysis(IEEEBrownBook)
NFPA70,NationalElectricalCode,NationalFire
ProtectionAssociation,Quincy,Massachusetts,
2005
ElectricalTransmissionandDistribution
ReferenceBook,ABBPowerT&DCompany,
Inc.,Raleigh,NorthCarolina,1997
ProtectiveRelayingTheoryandApplications,
MarcelDekker,Inc.,NewYork,2004
Anderson,P.M.,AnalysisofFaultedPower
Systems,IEEEPress,1995
St.Pierre,C.,APracticalGuidetoShortCircuit
Calculations,ElectricPowerConsultants,LLC,
Schenectady,NewYork,2001

CopyrightEPEProfessionalWebsiteDesignbyDBurnsDesign

Вам также может понравиться