Arkadian
blank
blank
Tel:
Fax:
3/18/2016

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
1

______________________________________________________________________________

1. Material List
.

Picture

Rated
Total
Cooling Cooling
Power Type
Capacity( Capacity(
kW)
kW)

Model

Memo

Unit

Qty.

Unit
Price($)

Sum
Price($)

AS242MGERA

Indoor
unit

set

1,220230,50/60

7.1

28.4

AS182MGERA

Indoor
unit

set

1,220230,50/60

5.6

5.6

AV12NMSETA

Outdoor
Unit

set

3,380400,50/60

33.5

33.5

FQG-B506A

Branch
Pipe

set

FQG-B335A

Branch
Pipe

set

YR-H71

Wireless
Controlle
r

set

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
2

______________________________________________________________________________

Picture

Total

Rated
Total
Cooling Cooling
Power Type
Capacity( Capacity(
kW)
kW)

Model

Memo

Unit

Qty.

Unit
Price($)

Sum
Price($)

Pipe-12.7

Copper
Pipe

5.67

Pipe-15.88

Copper
Pipe

11.9

Pipe-9.52

Copper
Pipe

23.9

Pipe-19.05

Copper
Pipe

12

Pipe-25.4

Copper
Pipe

5.67

R410A

Refrigera
nt

Kg

1.9

67.5

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
3

______________________________________________________________________________

2. Room List
.

Name

Area(m)

Type

Cooling
Design
Load(kW)

Cooling
Actual
Load(kW)

Heating
Design
Load(kW)

Heating
Actual
Load(kW)

Qty.

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
4

______________________________________________________________________________

3. System Construction
3.1 System1--ODU001
3.1.1 ODU

AV12NMSETA

Running Condition

Max. Combination

110%

Temperature

Actual Combination

101%

Cooling

Cooling Capacity
(Corrected/Rated)

33.16/33.5kW

Ind.WB

19C

Ind.DB

20C

Heating Capacity
(Corrected/Rated)

37.16/37.5kW

Out.DB

46C

Out.WB

6.5C

Power Supply

3,380400,50/60

Length And Drop

Dimensions

Max.Len.

Width

1050mm

Height

1636mm

Depth

400mm

Weight

168Kg

Picture

Heating

19.67m

0m

Max.Drop

Model

Width(mm)

Height(mm)

Depth(mm)

AV12NMSETA

1050

1636

400

MCA(A) MFA(A)

26

40

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
5

______________________________________________________________________________
3.1.2 IDU

Picture

Name

Model

Cooling
Capacity(Co
rrected/Rate
d)(kW)

Heating
Capacity(Co
rrected/Rate
d)(kW)

IDU00
1

AS242MG
ERA

6.9/7.1

8/8

1046*239*
299

IDU00
2

AS242MG
ERA

6.9/7.1

8/8

IDU00
3

AS242MG
ERA

6.9/7.1

IDU00
4

AS242MG
ERA

IDU00
5

AS182MG
ERA

Size_WDH Weight(
Kg)
(mm)

Controller

MCA(A)

MFA(A)

13

YR-H71

0.25

1046*239*
299

13

YR-H71

0.25

8/8

1046*239*
299

13

YR-H71

0.25

6.9/7.1

8/8

1046*239*
299

13

YR-H71

0.25

5.4/5.6

6.3/6.3

1046*239*
299

13

YR-H71

0.25

Room

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
6

______________________________________________________________________________
3.1.3 Piping

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
7

______________________________________________________________________________

Pipes Length and Drop


Length Piping Rules

Current

Max

5.67 m

110 m

14 m

40 m

Max.Length between ODU and furthest IDU

19.67 m

150 m

Total Length of all pipes

29.57 m

300 m

Current

Max

Max.Drop between ODU and IDU(ODU higher)

50 m

Max.Drop between ODU and IDU(IDU higher)

40 m

0m

15 m

Max.Length between ODU and frist branch pipe


Max.Length between the frist branch pipe and each IDU

Height Piping Rules

Max.Drop between IDUS


Max.Drop between Valve Box

Refrigerant Charged
Initial Refrigerant Charged:

7.4 Kg

To be Provided:

1.9 Kg

Total

9.3 Kg

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
8

______________________________________________________________________________

3.1.4 Wiring

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
9

______________________________________________________________________________

3.1.5 Dip Switch


3.1.5. IDU(0:OFF, 1:ON)
When YR-E14 used in group control system , the first unit of group control connection is set as master unit;
Name

Name

Model

SW01

SW02/CN4144

SW03

SW07

SW08

ODU001

IDU001

AS242MGERA

00100111

0000

00000000

01

ODU001

IDU005

AS182MGERA

00100110

0000

00000000

01

ODU001

IDU002

AS242MGERA

00100111

0000

00000000

01

ODU001

IDU003

AS242MGERA

00100111

0000

00000000

01

ODU001

IDU004

AS242MGERA

00100111

0000

00000000

01

3.1.5. ODU (0:OFF, 1:ON)


The 1st & 2nd bit of BM1 of master unit should be set 0(Off position) before power on , after power on and finishing searching indoor and
outdoor address ,set 1st & 2nd bit of BM1 to 1 (On position).

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the
data used in this program is just for your information.
10

______________________________________________________________________________

4.Central Control

______________________________________________________________________________________________________________
The Haier Project Express is property of Haier Air-Con Elec.Corp.Ltd. Only the data published in the official documents is exactly correct.All the