Вы находитесь на странице: 1из 4

Native VLAN mismatch Error on Access Port

Cisco switches always have VLAN 1 as


the default VLAN, which is needed for many protocol communication between switches
like spanning-tree protocol for instance. Unfortunately you cant change or even delete the
default VLAN, it is mandatory.
The native VLAN is the only VLAN which is not tagged in a trunk, in other words, native
VLAN frames are transmitted unchanged.
Per default the native VLAN is VLAN 1 but you can change that.

#show interface Fa0/8 trunk


Port

Mode

Encapsulation

Status

Native vlan

Fa0/8

on

802.1q

other

To change it use the following command: switchport trunk native vlan <vlan number>
(config-if)#switchport trunk native vlan 2
(config-if)#do show interface f0/8 trunk
Port

Mode

Encapsulation

Status

Native vlan

Fa0/8

on

802.1q

other

The default VLAN is still VLAN 1.


#show vlan id 1
VLAN Name Status

Ports

- -

1 default active

Fa0/8, Gi0/1

I am having two switches connected by access port but with two different vlan at both end. On
both ends I got following Native VLAN mismatch discovered errors.

SW1# sh log

Aug

5 15:16:35.286: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:17:33.992: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:18:32.149: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:19:28.217: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:20:24.622: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:21:17.736: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:22:10.554: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:23:01.778: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


Aug

5 15:24:00.581: %CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered

on GigabitEthernet1/39 (14), with SW2 GigabitEthernet0/1/0 (2).


SW1#

SW1#show cdp nei det | b SW2


Device ID: SW2
Entry address(es):
IP address: 172.18.14.11
Platform: cisco ISR4331/K9,

Capabilities: Router Switch IGMP

Interface: GigabitEthernet1/39,
Holdtime : 151 sec

Port ID (outgoing port): GigabitEthernet0/1/0

Version :
Cisco

IOS

Software,

ISR

Software

(X86_64_LINUX_IOSD-UNIVERSALK9-M),

Version

15.6(1)S1, RELEASE SOFTWARE (fc3)


Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2016 by Cisco Systems, Inc.
Compiled Wed 09-Mar-16 18:32 by mcpre
advertisement version: 2
VTP Management Domain: ''
Native VLAN: 2 (Mismatch)
Duplex: full
Power Available TLV:
Power request id: 0, Power management id: 1, Power available: 0, Power
management level: -1
Management address(es):
IP address: 172.18.14.11
SW1#

The Configuration on the ports at both ends:

SW1(config-if)#do sh run int g1/39


Building configuration...
Current configuration : 133 bytes
!
interface GigabitEthernet1/39
description SW2 G0/1/0
switchport access vlan 14
switchport mode access
end
SW1#

SW2#sh run int g0/1/0


interface GigabitEthernet0/1/0

description MS-Network-MGMT
switchport access vlan 2
spanning-tree portfast
SW2#show cdp nei det

Device ID: SW1


Entry address(es):
IP address: 172.18.14.3
Platform: cisco WS-C4510R+E,

Capabilities: Router Switch IGMP

Interface: GigabitEthernet0/1/0,

Port ID (outgoing port): GigabitEthernet1/39

Holdtime : 121 sec


SW2#

In circumstances like this, where you are sure the mismatch is not a real problem, you may
consider to disable cdp for those interfaces to shut up those noise information.

SW2#show run int g1/39


Building configuration...
Current configuration : 148 bytes
!
interface GigabitEthernet1/39
description SW2 G0/1/0
switchport access vlan 14
switchport mode access
no cdp enable
end
SW2#