Page 1 of 10
DISPLAY T-CON
INVERTER
CN101
P802 PWR
CN11 ALT
LVDS (26 in)
CN3 LVDS
CN8 PWR
CN5
IR-REC/LED
POWER PCB
P803 INV
CN2
SPKR
P801 AC
MAIN PCB
MANUAL
KEYS AND
FRONT
JACKS
SMART2009-LCD509-V8
Page 2 of 10
Wiring Interconnect
Key
Standby**
Pin 1
Flow <-out >-in
CN1
CN3
C
N
8
LVDS
M
A
N
U
A
L
Pins 2, 4, 6, 8
12V Panel Power
CN10
BLANK
CN5
A
N
D
CN2
IR REC/LED
P802
P
8
0
3
Inverter
1. 24V<
2. 24V<
3. 24V<
4. 24V<
5. 24V<
6. Gnd
7. Gnd
8. Gnd
9. Gnd
10. Gnd
11. NC
12. BL On 5V<
13. Dim .1 to 3V<
14. NC
Power PCB
LED/IR
1. 5V<**
2. IR>
3. GND
4. LED Logo
5. LED Green (Power)
P
8 A
0 C
1
SPEAKERS
F
R
O
N
T
J
A
C
K
S
Main PCB
SMART2009-LCD509-V8
K
E
Y
S
Page 3 of 10
Dead Set
Dead Set
(No Sound and
No Picture or No LED)
Yes
Yes
Yes
Does
the secondary
12 volt source appear
at pin 8 of CN8 when
the on/off button is
pressed?
Does
a 2.4 volt on off
signal appear at pin
13 of CN8 when the
on/off button is
pressed?
No
No
No
Is
5 VDC present
at pins 10, 11, and 12 of
CN8 on the main module
when AC is
applied?
No
Is the
Power Good
(AC Detect) level
less than .07V at pin
14 of CN8
when AC is
applied?
Yes
Suspect a problem
with the SYSCON
circuit located on the
Main module.
SMART2009-LCD509-V8
Page 4 of 10
No or distorted Video
No or distorted
video
YES
NO
Does
the back light function
normally when the unit
is turned on?
YES
Is
the screen
discolored or does it
have streaks and dark
areas on the
screen?
NO
YES
Troubleshoot for
backlight problelms.
Replace
the Main
Module.
Examples
When
the input button
is pressed on the
receiver or remote, is
the on screen
display clear and
normal?
YES
NO
Using the
power distribution
diagram, are the
voltages normal at CN8
of the power supply
module?
SMART2009-LCD509-V8
NO
Suspect the
power supply
module.
Page 5 of 10
Backlight
Troubleshooting
Backlight Troubleshooting
NO
NO
Replace the
Power supply
module.
NO
Is
24 VDC present
at pins 1 through 5 of
P803 on the power PCB
when the unit is
turned
on?
Remove
AC, then unplug the
LVDS cable(s). Does 24 volts
return when AC is reapplied
and the unit
is turned on?
YES
Replace the
display. ***
Does
the back light
function and then
turn off or is there a
dark horizontal area
on the
screen?
YES
If it is
available , try one or both
inverters. If this does not
help, replace the LCD
display. ***
YES
Is 4.5VDC
present at pin 16
of P802 shortly (.5 sec)
after the unit is
turned on?
NO
Replace the
Main module.
YES
Page 6 of 10
No Sound
No Audio
NO
Using
the remote or
the manual keyboard,
access the audio menu to
assure the speakers are on
and the input selection is a
known good source.
Will this restore
audio?
YES
Problem
solved.
NO
Replace the
power supply
module.
Does the
power supply
generate the audio
supply voltages (24 VDC
at pins 3 and 4 of CN8)
when the unit is
turned
on?
YES
Replace the
Main module
SMART2009-LCD509-V8
Page 7 of 10
SMART2009-LCD509-V8
Page 8 of 10
SMART2009-LCD509-V8
Page 9 of 10
Factory Mode
The factory mode, necessary adjustments, and update procedures shown below can be
accessed in this unit using the supplied remote control transmitter.
To enter the factory mode, you must press Left Arrow (<), then Exit, then Enter within
approximately two seconds. To end this function, press exit or simply turn the television
off.