Академический Документы
Профессиональный Документы
Культура Документы
The installation procedure of cdr file transfer utility on IOP and other related info.
Guidelines:
1. If file tx utility is already existing on IOP, then before installing new one, uninstal the
old utility using already existing uninstal utility UNINST-IOP-FT in $AUDITP/.
2. In duplex IOP, always do instal/uninstal/patching on both IOP separately.
3. s/w rel on IOP should be 2219 (L2.9).
4. Copy all the files in CARTRIDGE from following path :
/capri_1/mitali/cdr/192/2.9_iop/
Procedure for installation of cdr Tx related executables for IOP :
1. Go to the directory "/u" in IOP, then create a directory "instal", using following
commands : cd /u mkdir install so that we can get a new directory "/u/instal".
All the files in the Helpline Portal have to copy into the new directory "/u/instal/".
2. For installing CDR FILE TRANSFER UTILITIES in IOP, perform the following
steps :
a. If IOP is not in WARM-START level, bring the IOP into WARM-START
level using CRP command
"INIT-IOP:2,1;"
b. login from root a/c
c. If cdr file transfer util is already existing on IOP, then uninstall the old one as
following :
cd $AUDITP
./UNINST-IOP-FT
Wait until the following successful un-installation msg comes :"Uninstallation
Complete"
"Removing the utility $AUDITP/UNINST-IOP-FT..........."
d. Go to /u/instal/ , Change the permissiom of INST-IOP-FT as following :
chmod +x INST-IOP-FT
Run INST-IOP-FT as :
./INST-IOP-FT
e. Wait until the following successful installation msg comes :"Installation Complete".
1
d. Go to $AUDITP
Run INST-IOP-PCH
e. Wait until the following successful patching msg comes :
"Patch Installation Complete".
f. After that bring the IOP to INSERVICE LEVEL.
g. Remove the directory "/u/cdr_pch/"
- End of Document-