Fire Protection

&
Jacket Repair
Of Electrical Cables

Global Headquarters in:


Vesterveien 15b 4613 Kristiansand Norway
Tel:+ 47 38 17 84 20 Fax: +47 38 17 84 10
E.mail: headquarter@fire-security.com
Stavanger Office: Boks 5024 Dusavik, 4084 Stavanger, Norway
Tel. + 47 51 54 52 90 Fax: + 47 51 83 91 51

headquarter@fire-security.com

Houston office: Nortech Inc. 16420 Park Ten Place, Suite 580, Houston Texas 77084.
Tel: +1 281-578-6900 Fax: +1 281-578-6991
henning@nortechinch.com
Brazil office: Detector Electronics Do Brazil Avenida das Americas 10.200, 15/16
CEP 22.793-082 Rio de Janeiro RJ, Brazil. Tel. + 55 21 3150-4700. Fax. + 55 21 3150-4757
detector@detector.com.br
Singapore office: HF Engineering PTE LTD, 2 Mistri Road, #11-00 HMC Building,
Tel. +65 6226 1277, Fax. +65 6226 2252 e-mail:
hfe@frigstad.com.sg
Dubai office: Cable Protection Systems F.Z.C. P.O. Box 932 Ajman, United Arab Emirates.
Tel. +971 50 6453425, Fax. + 971 4 8846002
jrx@fire-security.com
Nigeria office: Jagal Ventures Limited, 12 Oyinkan Abayomi Drive, P.O. Box 5107, Ikoyi, Lagos, Nigeria.
Tel.+ 234 1 261 7299, 261 0032, 269 3290, Fax.+234 1 261 2405269 4286, Mobil +234 803 400 1000
jim_reddy@jagal.com
Mexico office: Hytec S.A. DE C.V. Calle 59 Col. Miami, CD Del Carmen, Campeche, Mexico.
Tel. + 52 938 29091, Fax. + 52 938 31623
hitec@camp.com.mx

In a fire situation, our


systems will prevent:
1.

Ignition of the cable insulation.

2.

Release of toxic fumes from


the cable insulation.

3.

Release of poisonous gas (HCL)


from the cable insulation.

4.

The cable tray from melting


and collapsing.

Uncoated cables experience a short circuit after


less than 2 minutes in an oil fire while cables
coated with Fire Security coatings will function
up to 1 hour without a short circuit.

FS-1 is an in tumescent coating


system that will expand 100 times
its thickness under a fire.

Areas of application
Upgrading of existing cables in order to
provide fire resistant properties in
accordance with the IEC-Publication 331.
Our coating has been tested in a
hydrocarbon fire for 60 minutes.
Upgrading of existing cables in order to
withstand hydrocarbon fire conditions of
1100 degree Celsius.

The orange curve shows the


temperature of an ISO fire which
is a fire in a normal building.
The red curve shows the
temperature of an oil fire, which is
the temperature Fire Security has
tested their coatings.
This is the temperature you will be
facing if you had a fire.

Areas of application
Protecting vital cables of the emergency
systems that are running through high-risk
areas compared to the alternative of
changing or re-routing them.
To comply with Solas convention
regulations with regards to fire stops.
Living quarters where it is required to
make existing cable halogen free.

Areas of application
To repair cable jackets that have been or
may be damaged by synthetic oil, mud and
drilling fluids etc.
To repair cable jackets that have cracked
and allowing water ingress and corrosion
to occur.
To repair cable jackets that have been
damaged by heat or outdoor environments.

Fire Security
Fire Security is a company specializing
in repair and protection of electrical
cables, offering our systems with specially
trained personnel for applications worldwide.

Fire- Security is offering


the following:

Application of our systems in required


thickness including cleaning of cables
prior to application.
Any discussion/contact with the
appropriate authorities and/or
classification societies involved.
Issue of necessary documentation,
including a Fire Security certificate.
On-site survey & inspection, Followed by
a written report, and an offer.

Advantages with our


systems

Your cables can be upgraded to the


highest level of fire safety at a very
reasonable cost.
For a small amount of money our
systems will prevent future damage to
your cable jackets.
Repair of already damaged cables.

No. Type
1 Fire Security Certificate
2 Product description and type approval
from DNV
3 Germanischer Lloyd
4 Type approval from ABS
5
6
7
8
9
10
11
12
13
14
15
16

10

Type approval from US Coast Guard


UL classification
Approval From Norwegian Maritime
Directorate
Ageing test
Mud-Oil-Water Resistance
Resistant to H2S
Halogen Protection
HC test report
Test report for no heat increase as a
result of coating
Insulation property improvement
Statement for customers
World-Wide references

pages
12
13-17
18-20
21-22
23
24-25
26-27
28-29
30-34
35-36
37
38-39
40
41-42
43-51
52-54

11

12

13

14

15

16

17

18

Cable Protection Systems


Mr. Jesper Rexen

19

Date Issued: 09/JUN/1999


Certificate Number: 99-HG48376-X

Certificate of Type Approval (RQS)


This is to certify that Fire Security A/S
has met the requirements of ABS Product Type Approval for
Fire Sec FS 1 and FS5
Model Name(s): Not Applicable
Presented to:
Fire Security A/S
Vesterveien 15 B
Kristiansand
N-4613
Norway
Intended Service:
To prevent propagation of fire on electrical cables, thereby upgrading the flame retardancy of the installed cables
to an equivalent of IEC 332-3 Category A
Description:
FS 1 and FS 5 are fire retardant coatings for upgrading of flame retardancy of electric cables and are capable of
providing up to 60 minutes of short circuit protection at 1000C for a single layer cable, in analogy to IEC 60331.
Ratings:
Fire Retardancy Coating System
Service Restrictions:
FS 1 is approved as an intumescent fire retardant coating on indoor cables; FS 5 is approved as an ablative fire
retardant coating on indoor and outdoor cables
Comments:
Not Applicable
Term of Validity:
Copyright 2001 American Bureau of Shipping. All rights reserved.

20

Page - 1

ABS Rules:
2003 Steel Vessel Rules 4-8-3/9.5
National Standards:
International Standards:
IEC 60332-3
Government Authority:
Others:

Manager, ABS Programs


ABS has used due diligence in the preparation of this certificate and it represents the information on the product in the ABS Records as of
the date and time the certificate was printed. Type Approval requires Drawing Assessment, Prototype Testing and assessment of the
manufacturer's quality assurance and quality control arrangements. Limited circumstances may allow only Prototype Testing to satisfy Type
Approval. The approvals of Drawings and Products remain valid as long as the ABS Rule, to which they were assessed, remains valid. ABS
cautions manufacturers to review and maintain compliance with all other specifications to which the product may have been assessed.
Further, unless it is specifically indicated in the description of the product; Type Approval does not necessarily waive witnessed inspection or
survey procedures (where otherwise required) for products to be used in a vessel, MODU or facility intended to be ABS classed or that is
presently in class with ABS. Questions regarding the validity of ABS Rules or the need for supplemental testing or inspection of such
products should, in all cases, be addressed to ABS.
Printed on : 2003-05-14 05:43:51.026

Copyright 2001 American Bureau of Shipping. All rights reserved.

Page - 2

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

Fire Security as Norway received

40

41

-----Opprinnelig melding----Fra: Rig_CAJ, Maintenance Supervisor [mailto:maintenance@caj.rig.deepwater.com]


Sendt: 20. februar 2004 13:00
Til: 'Ole Tom Eidjord'
Kopi: 'Rig_CAJ, Oim'; 'Nygrin, Stan'
Emne: RE: PO nr
Ole Tom,
We here on the Cajun Express are very pleased with the cable coating job that your company
has preformed for us in the sack room. The job was carried out in a very efficient and professional
manor. Mr. Jan Quarsten and Mr. Ketil Bjorkaas were very professional and a pleasure to work with.
We had considered replacing and rerouting the cables which would have been very expensive, and all
electrical equipment related to this wiring would have been shut down indefinitely during this job. With
the cable coating we were able to isolate only the wires that needed insulation repairs which your
company preformed before coating any cables. One of Transocean's core values is finical discipline
and I feel we have meet this by using your company to coat the wires instead of replacing them. I
would recommend your company to any one of our rigs that may be having similar problems as we
had. Again I would to thank your company for a job well done.
Regards,
Larry

Larry Robnett / Gerald Scoggins


Maintenance Supervisor's
Cajun Express
Tel: (713) 232-8251 Ext:373
Fax: (206)-339-5149
Email: <maintenance@caj.rig.deepwater.com>

42

43

44

45

46

47

48

49

50

Вам также может понравиться