Вы находитесь на странице: 1из 85

http://catalog.moeller.

net Contents 7/1


Moeller HPL0211-2007/2008

Small enclosures CI-K, empty enclosures CI


Rotary switches T,

Rotary switches T, switch-disconnectors P,


switch-disconnectors P, Rotary switches, switch-disconnectors Mini rotary switches Small enclosures, empty enclosures

Small enclosures CI-K


ATEX
Page Page Page

Technical overview 7/2 Technical overview 7/2 System overview 7/60


The powerful, rugged and compact cam System overview 7/4 Description 7/9 Ordering 7/61
switches and switch-disconnectors are used in Rotary switches 7/4 Key to part numbers, modular system 7/9 Basic enclosures 7/61
industry, workshops and in building services Switch-disconnectors 7/6 System overview 7/52 Accessories 7/64
management. The basic switch types of four Description 7/8 Ordering 7/54 Technical data 7/75
different construction types and with a wide Key to part numbers, modular system 7/8 Control circuit isolator, ON/OFF switch 7/54 Dimensions 7/88
range of standard contact sequences and rating Ordering 7/9 Changeover switch, hand/automatic 7/55
ranges are available. switch
Load current switches, main switches, 7/10
maintenance/repair switches Control switch, step switch 7/56
Load current switches, ON/OFF 7/21 Control switch - group switch, ON 7/58
switches (OFF) button, reversing switch, coding
switch
Load current switches, changeover 7/25
contacts Locks, front plates 7/59
Load-current switch - Safety switch 7/30 Technical data 7/74
Load current switch - reversing switch 7/32 Dimensions 7/88
TM/T rotary switches Load current switches, (reversing) 7/33
- up to 10/132 kW star-delta switches
- Non-standard circuits possible (EK)
load-current switch - pole-change 7/34
- Various types of construction switch
Page 7/52
Control switch, step switch 7/35
Control switch: ON/OFF switch, 7/37
changeover, hand/auto switch
Control switch - hand/auto switch 7/38
Control switch - ON buttons, universal 7/40
control switches
Switch for ATEX Zone 22
- TT rotary switches Control switch - instrument selector 7/40
switches
- P1 and P3 switch-disconnectors
- Degree of protection IP65 Switch with locking mechanism 7/41
Page 7/4 Main switch assembly kits, thumb- 7/43
grip, maintenance key
Front plates 7/44
Add-on front plates 7/45
key operation, locking interlock 7/46
Neutral conductor, auxiliary contact, 7/48
central mounting accessories,
service distribution board mounting
accessories
Coupling drive, interlock parts, shaft 7/49
extension
Shrouds, keys 7/50
Insulated enclosures, accessories 7/51
Technical data 7/67
Switch-disconnectors 7/67
Switch-disconnectors, auxiliary 7/69
CI-K enclosure system
P switch-disconnectors contacts
- Switch protection in IP65 Rotary switches
- Up to 110 kW and 315 A 7/70
- Individual laser inscription
- P1 and P3 in IP65 enclosure - Customized cutouts Dimensions 7/76
- 4 different types of construction - Cable entry as push-through
Page 7/6 diaphragm or
- knockout
Page 7/60
7/2 Technical overview Technical overview 7/3
(Mini) Rotary switch, switch-disconnector (Mini) Rotary switch, switch-disconnector
T, P, TM Moeller HPL0211-2007/2008 http://catalog.moeller.net http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P, TM
Rotary switches, switch-disconnectors

Rotary switches, switch-disconnectors


Switch, basic type Part no. TM T0 T3 T5(B) T5 T6 T8 P1-25 P1-32 P3-63 P3-100 P5-125 P5-160 P5-250 P5-315
Max. rated operatioal power 3.0 kW 6.5 kW 13 kW 22 kW 30 kW 55 kW 132 kW 13 kW 15 kW 37 kW 50 kW 45 kW 55 kW 90 kW 110 kW
AC-23 A, 400/415 V, 50/60 Hz
Max. rated operational current Iu 10 A 20 A 32 A 63 A 100 A 160 A 315 A 25 A 32 A 63 A 100 A 125 A 160 A 250 A 315 A

Load current switches


Main switch, maintenance/manual override switch a 7/10 a 7/10 a 7/10 a 7/12 a 7/15 a 7/15 a 7/10 a 7/10 a 7/10 a 7/11 a 7/11 a 7/11 a 7/11 a 7/12

On-Off switches a 7/54 a 7/21 a 7/21 a 7/21 a 7/24 a 7/21 a 7/22 a 7/22 a 7/22 a 7/22 a 7/22 a 7/22 a 7/22
Safety switches with warning label a 7/30 a 7/30 a 7/30 a 7/30 a 7/30 a 7/30
Changeover switches a 7/25 a 7/25 a 7/26 a 7/26 a 7/26 a 7/26
Reversing switches with 0 (Off) position a 7/32 a 7/32 a 7/32
Star-delta switches a 7/33 a 7/33 a 7/33
Reversing star-delta switches a 7/33 a 7/33 a 7/33
Multi-speed switches a 7/34 a 7/34 a 7/34
Reversing multi-speed switches a 7/33 a 7/33 a 7/33
Control switches
Step switches a 7/56 a 7/35
On-Off switches a 3/37
Changeover switches a 7/55 a 3/37
Hand/Auto switches a 7/55 a 3/37
Spring-return switches a 7/39
Universal control switch a 7/39
Coding switches a 7/58 a 7/40
Series switches a 7/40
Instrument selector switches a 7/40
Group switches a 7/58
On-Off switches, spring-return a 7/58
Reversing switches a 7/58
Switches with interlocks
Panic switchs without Emergency-Stop function a 7/41 a 7/41 a 7/41
On-Off switches without Emergency-Stop function a 7/42 a 7/42 a 7/41
Non-standard switches a Electronic catalogue, http://catalog.moeller.net a Electronic catalogue, http://catalog.moeller.net

Mounting form
Surface mounting /I

ATEX

Surface mounting main switch /I/SVB



ATEX

Flush mounting .../E

Flush mounting main switches /E(A)/SVB

Centre mounting /EZ

Rear mounting /Z

Rear mounting main switch /V/SVB

Service distribution board mounting /IVS


7/4 System overview
Rotary switches
T Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

ON-OFF switch T0, T3, T5B, T5

2
1

10

10

ATEX
5

9
9

8
8

7
6
7
6

Control switches T0, T3, T5B, T5

ATEX
4

10
10

9
9
System overview 7/5
Rotary switch
http://catalog.moeller.net Moeller HPL0211-2007/2008

Rotary switches, switch-disconnectors


Service distribution board mounting 1 Centre mounting (.../EZ) 3 Main switch (mounting kit) for use as 6
(/IVS) Emergency-Stop device
Front IP30 Front IP65
for snap fitting to IEC/EN 60 715 top-hat Mounting in fixing hole o 22,3 according To IEC/EN 60204-1, VDE 0113 Part 1
rail to IEC/EN 60947-5-1
Flush mounting "One man mounting" by centre fixing With red rotary handle and yellow lokking
ring
in service distribution board up to 3
height units (45 mm mounting depth) a page 7/21 Lockable in the 0 position
a page 7/43
in control panel up to 11 height units
Surface mounting (.../I...) 4
IP65 Main switch (kit) 7
a page 7/21
Black rotary handle and locking ring
Rear mounting (.../Z) 2
with an additional terminal Lockable in the 0 position
Front IP65 Enclosures for metric cable glands to a page 7/43
Fixing either by snap-on or screw fixing EN 50262
(T0, T3) a page 7/21
Thumb-grip, for use as Emergency- 8
for snap fitting to IEC/EN 60 715 top-hat Stop device
rail Surface mounting,main switch (.../I...) 4 To IEC/EN 60 204-1, VDE 0113 Part 1
Drive coupling in door or cover
IP65 Red thumb grip and yellow front plate
Connection from front
a page 7/43
a page 7/21
To IEC/EN 60 204, VDE 0113
Thumb-grip 9
Rear mounting main switch (...V/SVB) 2 and IEC/EN 60 947-3,
Black thumb-grip with front plate
for T0... up to 8 and for T3...
Front IP65 a page 7/43
up to 10 current paths
To IEC/EN 60 204, VDE 0113
Position 0 lockable with 3 padlocks
and IEC/EN 60 947-3, Coupling drive 10
Enclosures for metric cable glands to
for T0... up to 8 and for T3... EN 50262
Including shaft
up to 12 current paths with an additional terminal
for retrofiiting of switch T0(T3)-.../XZ in
with door interlock in "I" position a page 7/10 rear mounting form Replacement part for
T0(T3)/(P1)-.../Z
a page 7/10
ATEX for the conversion of switch T5(B)-.../E to
Flush mounting (.../E) 3 rear mounting switch Replacement part
a page 7/43 for T5(B)/(P3)-...Z
Front IP65
Mounting and connection from rear a page 7/49
Safety switch (.../I...) 5
Terminals:
IP65
Crosshead screwdriver Pozidrive
Finger- and back-of-hand proof
with an additional terminal
T8 aways with connection bracket
with cover safety in 0 position
a page 7/21
Position 0 lockable with 3 padlocks
Enclosures for metric cable glands to
Flush mounting main switch (.../EA/ 3 EN 50262
SVB)
Label "Safety switch", colour: orange
Front IP65
To IEC/EN 60204, VDE 0113 a page 7/30
and IEC/EN 60947-3,
for T0... up to 8 and for T3...
up to 12 current paths ATEX
N and PE terminals a page 7/43
a page 7/10
7/6 System overview
Switch-disconnectors
P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

ON-OFF switches P1, P3

4
1

2
11
5
3 ATEX
11
6
10

ON OFF switches P5

3
4

2 12
12 13
4

13
4
4

7
8
8
10

10
System overview 7/7
Switch-disconnectors
http://catalog.moeller.net Moeller HPL0211-2007/2008 P

Rotary switches, switch-disconnectors


Service distribution board mounting (/ 1 Flush mounting main switch (.../EA/SVB) 3 Safety switch (.../I...-SI) 6
IVS) IP65
Front IP30 Front IP65
Fitting dimensions according to DIN 43880 To IEC/EN 60204, VDE 0113 and IEC/ with an additional terminal
EN 60 947-3
with cover safety in 0 position
for snap fitting to EN 50 022 top-hat rail N and PE terminals
Position 0 lockable with 3 padlocks 0 position with 3 padlocks
Space requirement 2 modules can be retrofitted Lockable
P1, 3 pole: 3 PLE
Label "Safety switch", colour: orange
P3, 3 pole: 4 space units a page 7/10
P3-,,,/IVS lockable with padlock in "0" Enclosures for metric cable glands to
position Centre mounting (.../EZ) 3 EN 50262
a page 7/21 a page 7/30
Front IP65
Rear mounting (.../Z) 2 Mounting in fixing hole o 22,3 according to

Front IP65
IEC/EN 60 947-5-1
"One man mounting" by centre fixing
ATEX
Fixing either by snap-on or screw fixing
a page 7/21 a page 7/43
for snap fitting to EN 50022 top-hat rail
Add-on modules 4 Main switch (mounting kit) for use as 7
Drive coupling in door or cover Switchable N conductor (early operation N/O Emergency-Stop device
contact)
Connection from front Auxiliary contacts To IEC/EN 60204-1, VDE 0113 Part 1
2 modules can be retrofitted Fingerproof With red rotary handle and yellow lokking ring

a page 7/21 Auxiliary contact, N/O contact: Lockable in the 0 position


always switched as load-shedding contact a page 7/43
Rear mounting main switch (...V/SVB) 2 (late operation on, early operation off)
a page 7/48 Main switch (kit) 8
Front IP65
To IEC/EN 60204, VDE 0113 and IEC/ Surface mounting (.../I...) 5 Black rotary handle and locking ring
EN 60 947-3
IP65
with door interlock in "I" position Lockable in the 0 position
a page 7/43
Maintenance key for commissioning or fault- with an additional terminal
finding Additional modules can be retrofitted
Position 0 lockable with 3 padlocks Thumb-grip, for use as Emergency-Stop 9
device
2 modules can be retrofitted P1: + 1, P3: + 2
To IEC/EN 60 204-1, VDE 0113 Part 1
Enclosures for metric cable glands to
a page 7/10 EN 50262 Red thumb-grip and yellow front plate
a page 7/21 a page 7/43
Flush mounting (.../E) 3
Front IP65 Surface mounting,main switch (.../I...) 5 Thumb-grip 10
Mounting and connection from rear Black thumb-grip with front plate
IP65 a page 7/43
Terminals:
Crosshead screwdriver Pozidrive
with an additional terminal Coupling drive 11
Finger- and back-of-hand proof
To IEC/EN 60204, VDE 0113 and IEC/ Including shaft
EN 60947-3 for the retrofitting of switch T0(T3)-.../XZ to
2 modules can be retrofitted
0 position with 3 padlocks rear mounting, replacement part for T0(T3)/
a page 7/21 Lockable (P1)-.../Z
Additional modules can be retrofitted:
for the conversion of T5(B)-.../E to rear
mounting switch, replacement part for T5(B)/
P1: + 1, P3: + 2 (P3)-...Z
Enclosures for metric cable glands to
EN 50262 a page 7/49
a page 7/10
Protective conductor terminal 12
ATEX Flush mounting, right
Service distribution board mounting, left
a page 7/43

Neutral terminal 13
Flush mounting, left
Service distribution board mounting, right

a page 7/48
7/8 Description
Key to part numbers, modular system
T0, T3, T5, T5B Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Rotary switches can be used for many switching and The switch chamber (contact unit = BE) contains 1 or T rotary switches and P switch-disconnectors are
control applications. For example as ON-OFF 2 contacts In our catalogue T Rotary Switches" are manufactured without PCB, CFC, asbestos and silicon.
switches, main switches, main/control switches, over 800 standard circuits (Please order under The contacts are free from cadmium.
instrument switches. The switch consists of a hand K115D/F/GB. Article number 077643). On the
actuator, the switch unit and the mounting following pages a selection of oue standard circuits. The CI-K... insulated enclosures are silicon and halogen
accessories free.

Rotary switches T0 and T3

Key to type references

T......... ... - ............................- .................. ... ../ . . . . . . . . . . . . . . . . . . . .

Switch size Number of contact chambers Contact sequence Mounting form


T0 or T3 = contact units (BE) number a Page 7/2

Using the modular system to convert the mounting form

CI-K1-T0
T0(3).../E EZ-T0 V/EA/SVB-T0 T0(3).../XZ IVS-T0 CI-K2-T3 DE-T0

V/EA/SVB-T0

T0-1-(T3-1-).../EA/SVB
T0(3).../EZ
. T0.../IVS1) T0-.../I1 T0(3).../Z1)
.
. T3-.../I2
T0-4-(T3-6-).../EA/SVB

T0-1-(T3-1-).../V/SVB
.
.
.
T0-4-(T3-6-).../V/SVB

TB5 Rotary switches

Key to type references

T......... ... - ............................- .................. ... ../ . . . . . . . . . . . . . . . . . . . .

Switch size Number of contact chambers Contact sequence Mounting form


T5(B) = contact units (BE) number a Page 7/2

Using the modular system to convert the mounting form T5(B)

T5(B)...E V/EA/SVB-T5 DE-P3 CI-K4-T5B


CI-K5-T5

V/EA/SVB-T5 SVB-P3

T5(B).../Z
T5(B).../EA/SVB T5B-.../I4
T5-.../I5

T5B-.../I4/SVB
T5(B).../V/SVB T5-.../I5/SVB

Note 1) including shaft


Ordering 7/9
Key to part numbers, modular system
http://catalog.moeller.net Moeller HPL0211-2007/2008 P1, P3, TM

Rotary switches, switch-disconnectors


P1 and P3 Switch-disconnectors

Key to type references

P. . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . .

Switch sizes Rated uninterrupted current Mounting form Part no. suffix Accessories
P1 or P3 a Page 7/2 (if required) from a Page 7/47
Add-on functions due to modular system

N-P...E or HI 11-P1/P3E or H-P... UV-P...


N-P...Z HI 11-P1/P3Z

3-pole basic unit Switched neutral Auxiliary contact Terminal shroud N + PE terminals,
.../E or .../Z Can be fitted left Can be fitted left can be fitted at also as cover interlock
or right or right top or bottom on .../Z-switches.
(for P1.../I: left only) (for P1.../I: left only)

Mini rotary switches TM


The mini rotary switch TM is a particulary small TM switches have continuous terminal markings
switch with a small space requirement. It is ideally starting with 1. Selection pages from a page 7/54
suited for small voltages and currents such as
electronic controls. For greater safety the contacts
are gold plated.

Key to type references

TM-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .

Number of contact chambers Contact sequence Mounting form Accessories


= contact units (BE) number a Page 7/2 a Page 7/59

Circuit representation
(see also ordering example in the electronic
Front plate inscription

START catalogue)
2
0
1
START

Bridge
1
2
3
4
5
6
7
8

Connection designation

Switch from 0 to 1 Switch from 1 to START Switch from 1 to 0


with automatic return to 1
contact 1 2 open, contact 1 2 open,
contact 3 4 open, contact 1 2 open, contact 3 4 open,
contact 5 6 open, contact 3 4 closed, contact 5 6 open,
contact 7 8 closed contact 5 6 open, contact 7 8 open
contact 7 8 remains closed

Switch from 0 to 2 Switch from 2 to START Switch from 2 to 0


with automatic return to 2
contact 1 2 closed, contact 1 2 open, contact 1 2 open,
contact 3 4 open, contact 3 4 open, contact 3 4 open,
contact 5 6 open, contact 5 6 closes early, contact 5 6 open,
contact 7 8 closed contact 7 8 opens late contact 7 8 open
7/10 Ordering
Load current switches, main switches, maintenance/repair switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact Main con- Auxiliary Max. motor Rated Design Protection type Part no. Price Std. pack
sequence ducting contacts rating uninterrupted Article no. see price
Front plate paths current list
no.
No. of AC-23A
poles 400/415 V
ON
50-60 Hz
OFF
N/O N/O N/ P Iu
FS 908 C kW A
Main switches, maintenance switches
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device
1 0 0 6.5 20 Surface mounting IP65 T0-1-8200/I1/SVB 1 off
0 1

207145
1 0 0 6.5 20 Flush mounting Front IP65 T0-1-8200/EA/SVB
1
2

053110
1 0 0 6.5 20 Rear mounting Front IP65 T0-1-8200/V/SVB
057856
1 0 0 13 32 Surface mounting IP65 T3-1-8200/I2/SVB
207200
1 0 0 13 32 Flush mounting Front IP65 T3-1-8200/EA/SVB
066576
1 0 0 22 63 Surface mounting IP65 T5B-1-8200/I4/SVB
207240
1 0 0 22 63 Flush mounting Front IP65 T5B-1-8200/EA/SVB
094279
2 0 0 6.5 20 Surface mounting IP65 T0-1-102/I1/SVB
0 1

207143
1
2
3
4

2 0 0 6.5 20 Flush mounting Front IP65 T0-1-102/EA/SVB


091078
2 0 0 6.5 20 Rear mounting Front IP65 T0-1-102/V/SVB
095824
2 0 0 13 32 Surface mounting IP65 T3-1-102/I2/SVB
207198
2 0 0 13 32 Flush mounting Front IP65 T3-1-102/EA/SVB
014374
2 0 0 13 32 Rear mounting Front IP65 T3-1-102/V/SVB
019120
2 0 0 22 63 Surface mounting IP65 T5B-1-102/I4/SVB
207238
2 0 0 22 63 Flush mounting Front IP65 T5B-1-102/EA/SVB
094469
2 0 0 30 100 Surface mounting IP65 T5-1-102/I5/SVB
207273
3 0 0 6.5 20 Surface mounting IP65 T0-2-1/I1/SVB
0 1

207147
1
2
3
4
5
6

3 0 0 6.5 20 Flush mounting Front IP65 T0-2-1/EA/SVB


038873
3 0 0 6.5 20 Rear mounting Front IP65 T0-2-1/V/SVB
043619
3 0 0 13 25 Surface mounting IP65 P1-25/I2H/SVB1)
226900
3 0 0 13 25 Surface mounting P1-25/I2/SVB
207293
3 0 0 13 25 Flush mounting Front IP65 P1-25/EA/SVB
041097
3 0 0 13 25 Rear mounting Front IP65 P1-25/V/SVB
055335
3 0 0 15 32 Surface mounting IP65 P1-32/I2H/SVB1)
227868
3 0 0 15 32 Surface mounting P1-32/I2/SVB
207314
3 0 0 15 32 Flush mounting Front IP65 P1-32/EA/SVB
081438
3 0 0 15 32 Rear mounting Front IP65 P1-32/V/SVB
095676
3 0 0 37 63 Surface mounting IP65 P3-63/I4/SVB
207343
3 0 0 37 63 Flush mounting Front IP65 P3-63/EA/SVB
031607
3 0 0 37 63 Rear mounting Front IP65 P3-63/V/SVB
048218
Notes 1) Enclosures with hard metric knock-outs
Ordering 7/11
Load current switches, main switches, maintenance/repair switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P

Rotary switches, switch-disconnectors


Contact Main Auxiliary Max. motor Rated Design Protection Part no. Price Std. pack
sequence conducting contacts rating uninterrupted type Article no. see price
Front plate no. paths current list

No. of poles AC-23A


ON
400/415 V
OFF
50-60 Hz
FS 908 N/O N/O N/ P Iu
C kW A
Main switches, maintenance switches
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device
3 0 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB 1 off
0 1

280898
3 0 0 45 125 Rear mounting Front IP65 P5-125/V/SVB
1
2
3
4
5
6

280914
3 0 0 50 100 Surface mounting IP65 P3-100/I5/SVB
207373
3 0 0 50 100 Flush mounting Front IP65 P3-100/EA/SVB
074320
3 0 0 50 100 Rear mounting Front IP65 P3-100/V/SVB
088558
3 0 0 55 160 Flush mounting Front IP65 P5-160/EA/SVB
280922
3 0 0 55 160 Rear mounting Front IP65 P5-160/V/SVB
280928
3 0 0 90 250 Flush mounting Front IP65 P5-250/EA/SVB
280936
3 0 0 90 250 Rear mounting Front IP65 P5-250/V/SVB
280942
3 0 0 110 315 Flush mounting Front IP65 P5-315/EA/SVB
280950
3 0 0 110 315 Rear mounting Front IP65 P5-315/V/SVB
280956
3+N 0 0 6.5 20 Surface mounting IP65 T0-2-8900/I1/SVB
0 1

207151
1
2
3
4
5
6
7
8

3+N 0 0 6.5 20 Flush mounting Front IP65 T0-2-8900/EA/SVB


207400
3+N 0 0 6.5 20 Rear mounting Front IP65 T0-2-8900/V/SVB
207405
3+N 0 0 13 25 Surface mounting IP65 P1-25/I2H/SVB/N1)
0 1

227860
3+N 0 0 13 25 Surface mounting P1-25/I2/SVB/N
1
2
3
4
5
6
N
N

207298
3+N 0 0 13 25 Flush mounting Front IP65 P1-25/EA/SVB/N
081587
3+N 0 0 13 25 Rear mounting Front IP65 P1-25/V/SVB/N
086333
3+N 0 0 15 32 Surface mounting IP65 P1-32/I2/SVB/N
207319
3+N 0 0 15 32 Surface mounting P1-32/I2H/SVB/N1)
227871
3+N 0 0 15 32 Flush mounting Front IP65 P1-32/EA/SVB/N
091079
3+N 0 0 15 32 Rear mounting Front IP65 P1-32/V/SVB/N
095825
3+N 0 0 37 63 Surface mounting IP65 P3-63/I4/SVB/N
207349
3+N 0 0 37 63 Flush mounting Front IP65 P3-63/EA/SVB/N
010398
3+N 0 0 37 63 Rear mounting Front IP65 P3-63/V/SVB/N
015144
3+N 0 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB/N
280910
3+N 0 0 45 125 Rear mounting Front IP65 P5-125/V/SVB/N
280916
3+N 0 0 50 100 Surface mounting IP65 P3-100/I5/SVB/N
207379
3+N 0 0 50 100 Flush mounting Front IP65 P3-100/EA/SVB/N
019890
3+N 0 0 50 100 Rear mounting Front IP65 P3-100/V/SVB/N
024636
Notes 1) Enclosures with hard metric knock-outs
7/12 Ordering
Load current switches, main switches, maintenance/repair switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Main Auxiliary Max. Rated Design Protection Part no. Price Std. pack
Front plate no. conduct- contacts motor uninter- type Article no. see price
ing rating rupted list
ON
paths current
OFF
No. of AC-23A
FS 908
poles 400/415 V
50-60 Hz
N/O N/ N P Iu
O /
C
kW A
Main switches, maintenance switches
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device
3+N 0 0 55 160 Flush mounting Front IP65 P5-160/EA/SVB/N 1 off
0 1

280924
3+N 0 0 55 160 Rear mounting Front IP65 P5-160/V/SVB/N
1
2
3
4
5
6
N
N

280930
3+N 0 0 90 250 Flush mounting Front IP65 P5-250/EA/SVB/N
280938
3+N 0 0 90 250 Rear mounting Front IP65 P5-250/V/SVB/N
280944
3+N 0 0 110 315 Flush mounting Front IP65 P5-315/EA/SVB/N
280952
3+N 0 0 110 315 Rear mounting Front IP65 P5-315/V/SVB/N
280958
6 0 0 6.5 20 Surface mounting IP65 T0-3-8342/I1/SVB
0 1

207159
1
2
3
4
5
6
7
8
9
10
11
12

6 0 0 6.5 20 Flush mounting Front IP65 T0-3-8342/EA/SVB


029382
6 0 0 6.5 20 Rear mounting Front IP65 T0-3-8342/V/SVB
034128
6 0 0 13 32 Surface mounting IP65 T3-3-8342/I2/SVB
207208
6 0 0 13 32 Flush mounting Front IP65 T3-3-8342/EA/SVB
071326
6 0 0 13 32 Rear mounting Front IP65 T3-3-8342/V/SVB
076072
6 0 0 22 63 Surface mounting IP65 T5B-3-8342/I4/SVB
207242
6 0 0 22 63 Flush mounting Front IP65 T5B-3-8342/EA/SVB
092308
6 0 0 22 63 Rear mounting Front IP65 T5B-3-8342/V/SVB
092300
6 0 0 30 100 Surface mounting IP65 T5-3-8342/I5/SVB
207279
6 0 0 30 100 Flush mounting Front IP65 T5-3-8342/EA/SVB
096383
6 0 0 30 100 Rear mounting Front IP65 T5-3-8342/V/SVB
096381
8 0 0 6.5 20 Surface mounting IP65 T0-4-8344/I1/SVB
0 1

207163
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

8 0 0 6.5 20 Flush mounting Front IP65 T0-4-8344/EA/SVB


008267
8 0 0 6.5 20 Rear mounting Front IP65 T0-4-8344/V/SVB
014007
8 0 0 13 32 Surface mounting IP65 T3-4-8344/I2/SVB
207212
8 0 0 13 32 Flush mounting Front IP65 T3-4-8344/EA/SVB
008964
8 0 0 13 32 Rear mounting Front IP65 T3-4-8344/V/SVB
020598
8 0 0 22 63 Surface mounting IP65 T5B-4-8344/I4/SVB
207248
8 0 0 22 63 Flush mounting Front IP65 T5B-4-8344/EA/SVB
092062
8 0 0 22 63 Rear mounting Front IP65 T5B-4-8344/V/SVB
092056
8 0 0 30 100 Surface mounting IP65 T5-4-8344/I5/SVB1)
207283
8 0 0 30 100 Flush mounting Front IP65 T5-4-8344/EA/SVB
095961
Notes 1) Rated uninterrupted current max. 95 A
Ordering 7/13
Load current switches, main switches, maintenance/repair switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P

Rotary switches, switch-disconnectors


Contact sequence Main Auxiliary contacts Max. motor Rated Design Protection Part no. Price Std. pack
Front plate no. conducting rating uninter- type Article no. see
ON paths rupted price list
OFF current
FS 908
No. of AC-23A
poles 400/415 V
50-60 Hz
N/O N/O N/C P Iu
kW A

Main switches, maintenance switches


According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device
3 1 0 6.5 20 Surface IP65 T0-2-15679/I1/SVB 1 off
0 1

mounting 207149
1
2
3
4
5
6
7
8

3 1 0 6.5 20 Flush mounting Front IP65 T0-2-15679/EA/SVB


081588
3 1 0 6.5 20 Rear mounting Front IP65 T0-2-15679/V/SVB
086334

3 1 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB/HI10


0 1

280899
1
2
3
4
5
6
13
14

3 1 0 45 125 Rear mounting Front IP65 P5-125/V/SVB/HI10


280915

3 1 0 55 160 Flush mounting Front IP65 P5-160/EA/SVB/HI10


280923
3 1 0 55 160 Rear mounting Front IP65 P5-160/V/SVB/HI10
280929

3 1 0 90 250 Flush mounting Front IP65 P5-250/EA/SVB/HI10


280937
3 1 0 90 250 Rear mounting Front IP65 P5-250/V/SVB/HI10
280943

3 1 0 110 315 Flush mounting Front IP65 P5-315/EA/SVB/HI10


280951
3 1 0 110 315 Rear mounting Front IP65 P5-315/V/SVB/HI10
280957

3 1 1 13 25 Surface IP65 P1-25/I2/SVB/HI11


0 1

mounting 207297
1
2
3
4
5
6
13
14
21
22

3 1 1 13 25 Surface IP65 P1-25/I2H/SVB/HI111)


mounting 226902
3 1 1 13 25 Flush mounting Front IP65 P1-25/EA/SVB/HI11
091080
3 1 1 13 25 Rear mounting Front IP65 P1-25/V/SVB/HI11
095826

3 1 1 15 32 Surface IP65 P1-32/I2/SVB/HI11


mounting 207318
3 1 1 15 32 Surface IP65 P1-32/I2H/SVB/HI111)
mounting 227870
3 1 1 15 32 Flush mounting Front IP65 P1-32/EA/SVB/HI11
072567
3 1 1 15 32 Rear mounting Front IP65 P1-32/V/SVB/HI11
015145

3 1 1 37 63 Surface IP65 P3-63/I4/SVB/HI11


mounting 207348
3 1 1 37 63 Flush mounting Front IP65 P3-63/EA/SVB/HI11
019891
3 1 1 37 63 Rear mounting Front IP65 P3-63/V/SVB/HI11
024637

3 1 1 50 100 Surface IP65 P3-100/I5/SVB/HI11


mounting 207378
3 1 1 50 100 Flush mounting Front IP65 P3-100/EA/SVB/HI11
029383
3 1 1 50 100 Rear mounting Front IP65 P3-100/V/SVB/HI11
034129

Notes 1) Enclosures with hard metric knock-outs


7/14 Ordering
Load current switches, main switches, maintenance/repair switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Main con- Auxiliary Max. motor Rated unin- Design Protection Part no. Price Std.
Front plate no. ducting contacts rating terrupted type Article no. see pack
ON
paths current price
OFF list
FS 908 No. of AC-23A
poles 400/415 V
50-60 Hz
N/O N/ N/C P Iu
O kW A

Main switches, maintenance switches


According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device
3 2 1 6.5 20 Surface mounting IP65 T0-3-15683/I1/SVB 1 off
0 1

207157
1
2
3
4
5
6
7
8
9
10
11
12

3 2 1 6.5 20 Flush mounting Front IP65 T0-3-15683/EA/SVB


015571
3 2 1 6.5 20 Rear mounting Front IP65 T0-3-15683/V/SVB
015634
3 2 1 13 32 Surface mounting IP65 T3-3-15683/I2/SVB
207206
3 2 1 13 32 Flush mounting Front IP65 T3-3-15683/EA/SVB
040478
3+N 1 1 6.5 20 Surface mounting IP65 T0-3-15680/I1/SVB
0 1

207153
1
2
3
4
5
6
7
8
9
10
11
12

3+N 1 1 6.5 20 Flush mounting Front IP65 T0-3-15680/EA/SVB


038875
3+N 1 1 13 32 Surface mounting IP65 T3-3-15680/I2/SVB
207202
3+N 1 1 13 32 Flush mounting Front IP65 T3-3-15680/EA/SVB
012002
3+N 1 1 13 25 Flush mounting Front IP65 P1-25/EA/SVB/N/HI11
0 1

048367
1
2
3
4
5
6
N
N
13
14
21
22

3+N 1 1 13 25 Rear mounting Front IP65 P1-25/V/SVB/N/HI11


053113
3+N 1 1 15 32 Flush mounting Front IP65 P1-32/EA/SVB/N/HI11
057859
3+N 1 1 15 32 Rear mounting Front IP65 P1-32/V/SVB/N/HI11
062605
3+N 1 1 37 63 Surface mounting IP65 P3-63/I4/SVB/N/HI11
207350
3+N 1 1 37 63 Flush mounting Front IP65 P3-63/EA/SVB/N/HI11
067351
3+N 1 1 37 63 Rear mounting Front IP65 P3-63/V/SVB/N/HI11
072097
3+N 1 1 50 100 Surface mounting IP65 P3-100/I5/SVB/N/HI11
207380
3+N 1 1 50 100 Flush mounting Front IP65 P3-100/EA/SVB/N/HI11
076843
3+N 1 1 50 100 Rear mounting Front IP65 P3-100/V/SVB/N/HI11
081589
3+N 1 1 6.5 20 Surface mounting IP65 T0-3-8901/I1/SVB
0 1

231934
1
2
3
4
5
6
7
8
9
10
11
12

3+N 1 1 22 63 Surface mounting T5B-3-8901/I4/SVB


207244
6 1 1 6.5 20 Surface mounting IP65 T0-4-15682/I1/SVB
0 1

207161
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

6 1 1 6.5 20 Flush mounting Front IP65 T0-4-15682/EA/SVB


019892
6 1 1 6.5 20 Rear mounting Front IP65 T0-4-15682/V/SVB
024638
6 1 1 13 32 Surface mounting IP65 T3-4-15682/I2/SVB
207210
6 1 1 13 32 Flush mounting Front IP65 T3-4-15682/EA/SVB
054716
6 1 1 13 32 Rear mounting Front IP65 T3-4-15682/V/SVB
059462
6 1 1 22 63 Surface mounting IP65 T5B-4-15682/I4/SVB
207246
6 1 1 22 63 Flush mounting Front IP65 T5B-4-15682/EA/SVB
207425
6 1 1 22 63 Rear mounting Front IP65 T5B-4-15682/V/SVB
207427
Ordering 7/15
Load current switches, main switches, maintenance/repair switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P

Rotary switches, switch-disconnectors


Contact sequence Main con- Auxiliary Max. Rated Design Protection Part no. Price Std. pack
Front plate no. ducting contacts motor uninter- type Article no. see price
paths rating rupted list
ON
current
OFF
No. of AC-23A
FS 908
poles 400/415 V
50-60 Hz
N/O N/ N/ P Iu
O C kW A

Main switches, maintenance switches


According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device

6 1 1 30 100 Surface mounting IP65 T5-4-15682/I5/SVB 1 off


0 1

207281
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

6 1 1 30 100 Flush mounting Front IP65 T5-4-15682/EA/SVB


207413
6 1 1 30 100 Rear mounting Front IP65 T5-4-15682/V/SVB
207415

6 1 1 55 160 Rear mounting Front IP65 T6-160-6/V/SVB/HI11


200619

6 1 1 55 160 Surface mounting IP65 T6-160-6/I45/SVB/HI111)


201448

6 1 1 132 315 Rear mounting Front IP65 T8-3-8342/V/SVB/HI112)


200620

6 1 1 132 315 Surface mounting IP65 T8-3-8342/I48/SVB/HI11


2)3)
201450
Main switches, maintenance switches
With black rotary handle and locking collar, lockable in the 0 position
Without Emergency-Stop function
1 0 0 6.5 20 Surface mounting IP65 T0-1-8200/I1/SVB-SW 1 off
0 1

207146
1
2

1 0 0 6.5 20 Flush mounting Front IP65 T0-1-8200/EA/SVB-SW


055483
1 0 0 13 32 Surface mounting IP65 T3-1-8200/I2/SVB-SW
207201
2 0 0 6.5 20 Surface mounting IP65 T0-1-102/I1/SVB-SW
0 1

207144
1
2
3
4

2 0 0 6.5 20 Flush mounting Front IP65 T0-1-102/EA/SVB-SW


093451
2 0 0 6.5 20 Rear mounting Front IP65 T0-1-102/V/SVB-SW
022330

2 0 0 13 32 Surface mounting IP65 T3-1-102/I2/SVB-SW


207199
2 0 0 13 32 Flush mounting Front IP65 T3-1-102/EA/SVB-SW
016747
3 0 0 6.5 20 Surface mounting IP65 T0-2-1/I1/SVB-SW
0 1

207148
1
2
3
4
5
6

3 0 0 6.5 20 Flush mounting Front IP65 T0-2-1/EA/SVB-SW


041246
3 0 0 6.5 20 Rear mounting Front IP65 T0-2-1/V/SVB-SW
045992

3 0 0 13 25 Surface mounting IP65 P1-25/I2/SVB-SW


207294
3 0 0 13 25 Surface mounting IP65 P1-25/I2H/SVB-SW4)
227861
3 0 0 13 25 Flush mounting Front IP65 P1-25/EA/SVB-SW
048365
3 0 0 13 25 Rear mounting Front IP65 P1-25/V/SVB-SW
050738

Notes 1) Enclosures without flanges with K95/1N/BR


2) with KS4-CI and K150/1/BR: Ingress protection IP64
3) Rated uninterrupted current 315 A in enclosed version max. 275 A
4) Enclosures with hard metric knock-outs
7/16 Ordering
Load current switches, main switches, maintenance/repair switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact Main Auxiliary Max. motor Rated Design Protection Part no. Price Std. pack
sequence conducting contacts rating uninterrupted type Article no. see price
Front plate no. paths current list
ON
No. of poles AC-23A
OFF
400/415 V
FS 908 50-60 Hz
N/O N/O N P Iu
/C kW A
Main switches, maintenance switches
With black rotary handle and locking collar, lockable in the 0 position
Without Emergency-Stop function

3 0 0 15 32 Surface IP65 P1-32/I2/SVB-SW 1 off


0 1

mounting 207315
1
2
3
4
5
6

3 0 0 15 32 Surface IP65 P1-32/I2H/SVB-SW1)


mounting 227872
3 0 0 15 32 Flush Front IP65 P1-32/EA/SVB-SW
mounting 053111
3 0 0 15 32 Rear Front IP65 P1-32/V/SVB-SW
mounting 055484
3 0 0 37 63 Surface IP65 P3-63/I4/SVB-SW
mounting 207344
3 0 0 37 63 Flush Front IP65 P3-63/EA/SVB-SW
mounting 057857
3 0 0 37 63 Rear Front IP65 P3-63/V/SVB-SW
mounting 060230
3 0 0 50 100 Surface IP65 P3-100/I5/SVB-SW
mounting 207374
3 0 0 50 100 Flush Front IP65 P3-100/EA/SVB-SW
mounting 062603
3 0 0 50 100 Rear Front IP65 P3-100/V/SVB-SW
mounting 064976
3 0 0 45 125 Flush Front IP65 P5-125/EA/SVB-SW
mounting 280911
3 0 0 45 125 Rear Front IP65 P5-125/V/SVB-SW
mounting 280917
3 0 0 55 160 Flush Front IP65 P5-160/EA/SVB-SW
mounting 280925
3 0 0 55 160 Rear Front IP65 P5-160/V/SVB-SW
mounting 280931
3 0 0 90 250 Flush Front IP65 P5-250/EA/SVB-SW
mounting 280939
3 0 0 90 250 Rear Front IP65 P5-250/V/SVB-SW
mounting 280945
3 0 0 110 315 Flush Front IP65 P5-315/EA/SVB-SW
mounting 280953
3+N 0 0 6.5 20 Surface IP65 T0-2-8900/I1/SVB-SW
0 1

mounting 207152
1
2
3
4
5
6
7
8

3+N 0 0 6.5 20 Flush Front IP65 T0-2-8900/EA/SVB-SW


mounting 207401
3+N 0 0 6.5 20 Rear Front IP65 T0-2-8900/V/SVB-SW
mounting 207406
3+N 0 0 13 25 Surface IP65 P1-25/I2/SVB-SW/N
0 1

mounting 207296
1
2
3
4
5
6
N
N

3+N 0 0 13 25 Surface IP65 P1-25/I2H/SVB-SW/N1)


mounting 227863
3+N 0 0 13 25 Flush Front IP65 P1-25/EA/SVB-SW/N
mounting 083960
3+N 0 0 13 25 Rear Front IP65 P1-25/V/SVB-SW/N
mounting 088706
3+N 0 0 15 32 Surface IP65 P1-32/I2/SVB-SW/N
mounting 207317
3+N 0 0 15 32 Surface IP65 P1-32/I2H/SVB-SW/N1)
mounting 227874
3+N 0 0 15 32 Flush Front IP65 P1-32/EA/SVB-SW/N
mounting 093452
3+N 0 0 15 32 Rear Front IP65 P1-32/V/SVB-SW/N
mounting 098198
3+N 0 0 37 63 Surface IP65 P3-63/I4/SVB-SW/N
mounting 207346
3+N 0 0 37 63 Flush Front IP65 P3-63/EA/SVB-SW/N
mounting 012771
3+N 0 0 37 63 Rear Front IP65 P3-63/V/SVB-SW/N
mounting 017517
Notes 1) Enclosures with hard metric knock-outs
Ordering 7/17
Load current switches, main switches, maintenance/repair switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P

Rotary switches, switch-disconnectors


Contact sequence Main Auxiliary Max. Rated Design Protection Part no. Price Std. pack
Front plate no. conduct- contacts motor uninter- type Article no. see
ing rating rupted price
ON
paths current list
OFF
No. of AC-23A
FS 908
poles 400/415 V
50-60 Hz
N/O N/ N/ P Iu
O C kW A

Main switches, maintenance switches


With black rotary handle and locking collar, lockable in the 0 position
Without Emergency-Stop function
3+N 0 0 50 100 Surface mounting IP65 P3-100/I5/SVB-SW/N 1 off
0 1

207376
1
2
3
4
5
6
N
N

3+N 0 0 50 100 Flush mounting Front IP65 P3-100/EA/SVB-SW/N


022263
3+N 0 0 50 100 Rear mounting Front IP65 P3-100/V/SVB-SW/N
027009
3+N 0 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB-SW/N
280913
3+N 0 0 45 125 Rear mounting Front IP65 P5-125/V/SVB-SW/N
280919
3+N 0 0 55 160 Flush mounting Front IP65 P5-160/EA/SVB-SW/N
280927
3+N 0 0 55 160 Rear mounting Front IP65 P5-160/V/SVB-SW/N
280933
3+N 0 0 90 250 Flush mounting Front IP65 P5-250/EA/SVB-SW/N
280941
3+N 0 0 90 250 Rear mounting Front IP65 P5-250/V/SVB-SW/N
280947
3+N 0 0 110 315 Flush mounting Front IP65 P5-315/EA/SVB-SW/N
280955
6 0 0 6.5 20 Surface mounting IP65 T0-3-8342/I1/SVB-SW
0 1

207160
1
2
3
4
5
6
7
8
9
10
11
12

6 0 0 6.5 20 Flush mounting Front IP65 T0-3-8342/EA/SVB-SW


031755
6 0 0 6.5 20 Rear mounting Front IP65 T0-3-8342/V/SVB-SW
036501
6 0 0 13 32 Surface mounting IP65 T3-3-8342/I2/SVB-SW
207209
6 0 0 13 32 Flush mounting Front IP65 T3-3-8342/EA/SVB-SW
073699
6 0 0 13 32 Rear mounting Front IP65 T3-3-8342/V/SVB-SW
078445
6 0 0 22 63 Surface mounting IP65 T5B-3-8342/I4/SVB-SW
207243
6 0 0 22 63 Flush mounting Front IP65 T5B-3-8342/EA/SVB-SW
092307
6 0 0 22 63 Rear mounting Front IP65 T5B-3-8342/V/SVB-SW
092299
6 0 0 30 100 Surface mounting IP65 T5-3-8342/I5/SVB-SW
207280
6 0 0 30 100 Flush mounting Front IP65 T5-3-8342/EA/SVB-SW
096382
6 0 0 30 100 Rear mounting Front IP65 T5-3-8342/V/SVB-SW
096380
8 0 0 6.5 20 Surface mounting IP65 T0-4-8344/I1/SVB-SW
0 1

207164
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

8 0 0 6.5 20 Flush mounting Front IP65 T0-4-8344/EA/SVB-SW


008268
8 0 0 13 32 Surface mounting IP65 T3-4-8344/I2/SVB-SW
207213
8 0 0 13 32 Flush mounting Front IP65 T3-4-8344/EA/SVB-SW
008965
8 0 0 13 32 Rear mounting Front IP65 T3-4-8344/V/SVB-SW
008967
8 0 0 22 63 Surface mounting IP65 T5B-4-8344/I4/SVB-SW
207249
8 0 0 22 63 Flush mounting Front IP65 T5B-4-8344/EA/SVB-SW
092061
8 0 0 30 100 Surface mounting IP65 T5-4-8344/I5/SVB-SW1)
207284

Notes 1) Rated uninterrupted current max. 95 A


7/18 Ordering
Load current switches, main switches, maintenance/repair switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Main Auxiliary Max. motor Rated Design Protection Part no. Price Std. pack
Front plate no. conduct- contacts rating uninter- type Article no. see price
ing rupted list
ON
paths current
OFF
AC-23A
FS 908 No. of 400/415 V
poles 50-60 Hz
N/O N/ N P Iu
O /
C kW A
Main switches, maintenance switches
With black rotary handle and locking collar, lockable in the 0 position
Without Emergency-Stop function
3 1 0 6.5 20 Surface mounting IP65 T0-2-15679/I1/SVB-SW 1 off
0 1

207150
1
2
3
4
5
6
7
8

3 1 0 6.5 20 Flush mounting Front IP65 T0-2-15679/EA/SVB-SW


083961
3 1 0 6.5 20 Rear mounting Front IP65 T0-2-15679/V/SVB-SW
088707
3 1 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB-SW/HI10
280912
3 1 0 45 125 Rear mounting Front IP65 P5-125/V/SVB-SW/HI10
280918
3 1 0 55 160 Flush mounting Front IP65 P5-160/EA/SVB-SW/HI10
280926
3 1 0 55 160 Rear mounting Front IP65 P5-160/V/SVB-SW/HI10
280932
3 1 0 90 250 Flush mounting Front IP65 P5-250/EA/SVB-SW/HI10
280940
3 1 0 90 250 Rear mounting Front IP65 P5-250/V/SVB-SW/HI10
280946
3 1 0 110 315 Rear mounting Front IP65 P5-315/V/SVB-SW/HI10
280960
3 1 1 13 25 Surface mounting IP65 P1-25/I2/SVB-SW/HI11
0 1

207295
1
2
3
4
5
6
13
14
21
22

3 1 1 13 25 Surface mounting IP65 P1-25/I2H/SVB-SW/HI111)


227862
3 1 1 13 25 Flush mounting Front IP65 P1-25/EA/SVB-SW/HI11
070194
3 1 1 13 25 Rear mounting Front IP65 P1-25/V/SVB-SW/HI11
098199
3 1 1 15 32 Surface mounting IP65 P1-32/I2/SVB-SW/HI11
207316
3 1 1 15 32 Surface mounting IP65 P1-32/I2H/SVB-SW/HI111)
227873
3 1 1 15 32 Flush mounting Front IP65 P1-32/EA/SVB-SW/HI11
012772
3 1 1 15 32 Rear mounting Front IP65 P1-32/V/SVB-SW/HI11
017518
3 1 1 37 63 Surface mounting IP65 P3-63/I4/SVB-SW/HI11
207345
3 1 1 37 63 Flush mounting Front IP65 P3-63/EA/SVB-SW/HI11
022264
3 1 1 37 63 Rear mounting Front IP65 P3-63/V/SVB-SW/HI11
027010
3 1 1 50 100 Surface mounting IP65 P3-100/I5/SVB-SW/HI11
207375
3 1 1 50 100 Flush mounting Front IP65 P3-100/EA/SVB-SW/HI11
031756
3 1 1 50 100 Rear mounting Front IP65 P3-100/V/SVB-SW/HI11
036502
3 2 1 6.5 20 Surface mounting IP65 T0-3-15683/I1/SVB-SW
0 1

207158
1
2
3
4
5
6
7
8
9
10
11
12

3 2 1 6.5 20 Flush mounting Front IP65 T0-3-15683/EA/SVB-SW


015600
3 2 1 13 32 Surface mounting IP65 T3-3-15683/I2/SVB-SW
207207
3 2 1 13 32 Flush mounting Front IP65 T3-3-15683/EA/SVB-SW
042851
3+N 1 1 6.5 20 Surface mounting IP65 T0-3-15680/I1/SVB-SW
0 1

207154
1
2
3
4
5
6
7
8
9
10
11
12

3+N 1 1 6.5 20 Flush mounting Front IP65 T0-3-15680/EA/SVB-SW


041248
3+N 1 1 13 32 Surface mounting IP65 T3-3-15680/I2/SVB-SW
207203
Notes 1) Enclosures with hard metric knock-outs
Ordering 7/19
Load current switches, main switches, maintenance/repair switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P

Rotary switches, switch-disconnectors


Contact sequence Main Auxiliary Max. motor Rated Design Protection Part no. Price Std.
Front plate no. conduct- contacts rating uninter- type Article no. see pack
ing paths rupted price
ON
current list
OFF
No. of AC-23A
FS 908
poles 400/415 V
50-60 Hz
N/O N/ N/ P Iu
O C kW A

Main switches, maintenance switches


With black rotary handle and locking collar, lockable in the 0 position
Without Emergency-Stop function
3+N 1 1 13 25 Flush mounting Front IP65 P1-25/EA/SVB-SW/N/HI11 1 off
0 1

050740
3+N 1 1 15 32 Flush mounting Front IP65 P1-32/EA/SVB-SW/N/HI11
1
2
3
4
5
6
7
8
9
10
11
12

060232
3+N 1 1 15 32 Rear mounting Front IP65 P1-32/V/SVB-SW/N/HI11
064978
3+N 1 1 37 63 Surface mounting IP65 P3-63/I4/SVB-SW/N/HI11
207347
3+N 1 1 37 63 Flush mounting Front IP65 P3-63/EA/SVB-SW/N/HI11
069724
3+N 1 1 37 63 Rear mounting Front IP65 P3-63/V/SVB-SW/N/HI11
074470
3+N 1 1 50 100 Surface mounting IP65 P3-100/I5/SVB-SW/N/HI11
207377
3+N 1 1 50 100 Flush mounting Front IP65 P3-100/EA/SVB-SW/N/HI11
079216
3+N 1 1 50 100 Rear mounting Front IP65 P3-100/V/SVB-SW/N/HI11
083962
3+N 1 1 6.5 20 Flush mounting Front IP65 T0-3-8901/EA/SVB-SW
0 1

231933
3+N 1 1 13 32 Surface mounting IP65 T3-3-8901/I2/SVB-SW
1
2
3
4
5
6
7
8
9
10
11
12

218988
3+N 1 1 22 63 Surface mounting IP65 T5B-3-8901/I4/SVB-SW
207245
3+N 1 1 22 63 Flush mounting Front IP65 T5B-3-8901/EA/SVB-SW
207421
3+N 1 1 30 100 Surface mounting IP65 T5-3-8901/I5/SVB-SW
207278
6 1 1 6.5 20 Surface mounting IP65 T0-4-15682/I1/SVB-SW
0 1

207162
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

6 1 1 6.5 20 Flush mounting Front IP65 T0-4-15682/EA/SVB-SW


022265
6 1 1 6.5 20 Rear mounting Front IP65 T0-4-15682/V/SVB-SW
027011
6 1 1 13 32 Surface mounting IP65 T3-4-15682/I2/SVB-SW
207211
6 1 1 13 32 Flush mounting Front IP65 T3-4-15682/EA/SVB-SW
057089
6 1 1 13 32 Rear mounting Front IP65 T3-4-15682/V/SVB-SW
061835
6 1 1 22 63 Surface mounting IP65 T5B-4-15682/I4/SVB-SW
207247
6 1 1 22 63 Flush mounting Front IP65 T5B-4-15682/EA/SVB-SW
207426
6 1 1 22 63 Rear mounting Front IP65 T5B-4-15682/V/SVB-SW
207428
6 1 1 30 100 Surface mounting IP65 T5-4-15682/I5/SVB-SW
207282
6 1 1 30 100 Flush mounting Front IP65 T5-4-15682/EA/SVB-SW
207414
6 1 1 30 100 Rear mounting Front IP65 T5-4-15682/V/SVB-SW
207416
6 1 1 55 160 Surface mounting IP65 T6-160-6/I45/SVB-SW/HI11
1)
201447
6 1 1 55 160 Rear mounting Front IP65 T6-160-6/V/SVB-SW/HI11
200127
6 1 1 132 315 Surface mounting IP65 T8-3-8342/I48/SVB-SW/
HI112)3)
201449
6 1 1 132 315 Rear mounting Front IP65 T8-3-8342/V/SVB-SW/HI113)
200128
Notes 1) Enclosureswithout flanges with K95/1N/BR
2) withKS4-CI and K150/1/BR: IP64
3) Rated uninterrupted current 315 A in enclosed version max. 275 A
7/20 Ordering
Load current switches, main switches, maintenance/repair switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact Main Auxiliary Max. motor Rated Design Protection Part no. Price Std. pack
sequence conducting contacts rating uninter- type Article no. see price
Front plate no. paths rupted list
current
ON
No. of poles AC-23A Iu
OFF

FS 908
400/415 V A
50-60 Hz
N/O N/O N/C P
kW

On-Off switches
As Emergency-Stop device
According to IEC/EN60204-1, VDE 113 Part 1
with red thumb grip and yellow front plate
1 0 0 6.5 20 Flush Front IP65 T0-1-8200/E-RT 1 off
0 1

mounting 009474
1
2

1 0 0 6.5 20 Distribution Front IP30 T0-1-8200/IVS-RT


board 081956
mounting

2 0 0 6.5 20 Surface IP65 T0-1-102/I1-RT


0 1

mounting 207062
1
2
3
4

2 0 0 6.5 20 Flush Front IP65 T0-1-102/E-RT


mounting 009046
2 0 0 22 32 Flush Front IP65 T3-1-102/E-RT
mounting 016318
3 0 0 6.5 20 Surface IP65 T0-2-1/I1-RT
0 1

mounting 207082
1
2
3
4
5
6

3 0 0 6.5 20 Flush Front IP65 T0-2-1/E-RT


mounting 011082
3 0 0 6.5 20 Distribution Front IP30 T0-2-1/IVS-RT
board 084329
mounting

3 0 0 13 25 Surface IP65 P1-25/I2-RT


mounting 207300
3 0 0 13 25 Flush Front IP65 P1-25/E-RT
mounting 002388
3 0 0 13 25 Distribution Front IP30 P1-25/IVS-RT
board 013140
mounting

3 0 0 15 32 Flush Front IP65 P1-32/E-RT


mounting 003197
3 0 0 15 32 Distribution Front IP30 P1-32/IVS-RT
board 022632
mounting

3 0 0 37 63 Flush Front IP65 P3-63/E-RT


mounting 005743
3 0 0 37 63 Distribution Front IP30 P3-63/IVS-RT
board 045845
mounting

3 0 0 50 100 Surface IP65 P3-100/I5-RT


mounting 207382
3 0 0 50 100 Flush Front IP65 P3-100/E-RT
mounting 007189
3 0 0 50 100 Distribution Front IP30 P3-100/IVS-RT
board 086185
mounting

3+N 0 0 6.5 20 Flush Front IP65 T0-2-8900/E-RT


0 1

mounting 207399
1
2
3
4
5
6
7
8
Ordering 7/21
Load current switches, ON/OFF switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P

Rotary switches, switch-disconnectors


Contact Main Auxiliary Max. motor Rated Design Protection Part no. Std. pack
sequence conducting contacts rating uninter- type Article no.
Front plate no. paths rupted
current
ON
No. of poles AC-23A
OFF
400/415 V
FS 908 N/O N/ N/ 50-60 Hz
O C P Iu
kW A
On-Off switches
with black thumb grip and front plate
Without auxiliary contacts
1 0 0 6.5 20 Surface mounting IP65 T0-1-8200/I1 1 off
0 1

207074
1
2

1 0 0 6.5 20 Flush mounting Front IP65 T0-1-8200/E


067352
1 0 0 6.5 20 Distribution board Front IP30 T0-1-8200/IVS
mounting 074471

1 0 0 6.5 20 Centre mounting Front IP65 T0-1-8200/EZ


069725
1 0 0 6.5 20 Rear mounting Front IP65 T0-1-8200/Z
076844
1 0 0 13 32 Flush mounting Front IP65 T3-1-8200/E
064208
1 0 0 13 32 Surface mounting IP65 T3-1-8200/I2
207167
1 0 0 13 32 Centre mounting Front IP65 T3-1-8200/EZ
066581
1 0 0 22 63 Flush mounting Front IP65 T5B-1-8200/E
094281
2 0 0 6.5 20 Surface mounting IP65 T0-1-102/I1
0 1

207061
2 0 0 6.5 20 Flush mounting Front IP65 T0-1-102/E
1
2
3
4

088709
2 0 0 6.5 20 Distribution board Front IP30 T0-1-102/IVS
mounting 015147

2 0 0 6.5 20 Centre mounting Front IP65 T0-1-102/EZ


091082
2 0 0 6.5 20 Rear mounting Front IP65 T0-1-102/Z
095828
2 0 0 22 32 Surface mounting IP65 T3-1-102/I2
207165
2 0 0 22 32 Flush mounting Front IP65 T3-1-102/E
076073
2 0 0 22 32 Centre mounting Front IP65 T3-1-102/EZ
078446
2 0 0 22 32 Rear mounting Front IP65 T3-1-102/Z
083192
2 0 0 22 63 Flush mounting Front IP65 T5B-1-102/E
094471
3 0 0 6.5 20 Surface mounting IP65 T0-2-1/I1
0 1

207081
1
2
3
4
5
6

3 0 0 6.5 20 Flush mounting Front IP65 T0-2-1/E


024639
3 0 0 6.5 20 Distribution board Front IP30 T0-2-1/IVS
mounting 031758

3 0 0 6.5 20 Centre mounting Front IP65 T0-2-1/EZ


027012
3 0 0 6.5 20 Rear mounting Front IP65 T0-2-1/Z
036504
3 0 0 13 25 Surface mounting IP65 P1-25/I2
207299
3 0 0 13 25 Surface mounting IP65 P1-25/I2H1)
226898
3 0 0 13 25 Flush mounting Front IP65 P1-25/E
038724
3 0 0 13 25 Distribution board Front IP30 P1-25/IVS
mounting 052962

3 0 0 13 25 Centre mounting Front IP65 P1-25/EZ


041250
3 0 0 13 25 Rear mounting Front IP65 P1-25/Z
057708
Notes 1) Enclosures with hard metric knock-outs
7/22 Ordering
Load current switches, ON/OFF switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact Main Auxiliary Max. motor Rated Design Protection Part no. Std. pack
sequence conducting contacts rating uninterrupted type Article no.
Front plate no. paths current
ON
No. of poles AC-23A
OFF

FS 908 400/415 V
N/O N/ N 50-60 Hz
O / P Iu
C
kW A
On-Off switches
with black thumb grip and front plate
Without auxiliary contacts
3 0 0 15 32 Surface mounting IP65 P1-32/I2 1off
0 1

207320
1
2
3
4
5
6

3 0 0 15 32 Surface mounting IP65 P1-32/I2H1)


227866

3 0 0 15 32 Flush mounting Front IP65 P1-32/E


079065
3 0 0 15 32 Distribution board Front IP30 P1-32/IVS
mounting 093303

3 0 0 15 32 Centre mounting Front IP65 P1-32/EZ


048369

3 0 0 15 32 Rear mounting Front IP65 P1-32/Z


098049
3 0 0 37 63 Surface mounting IP65 P3-63/I4
207356
3 0 0 37 63 Flush mounting Front IP65 P3-63/E
026861
3 0 0 37 63 Distribution board Front IP30 P3-63/IVS
mounting 041099

3 0 0 37 63 Rear mounting Front IP65 P3-63/Z


050591
3 0 0 45 125 Flush mounting Front IP65 P5-125/E
280897
3 0 0 45 125 Rear mounting Front IP65 P5-125/Z
280920
3 0 0 50 100 Surface mounting IP65 P3-100/I5
207381
3 0 0 50 100 Flush mounting Front IP65 P3-100/E
067201
3 0 0 50 100 Distribution board Front IP30 P3-100/IVS
mounting 081439

3 0 0 50 100 Rear mounting Front IP65 P3-100/Z


090931
3 0 0 55 160 Flush mounting Front IP65 P5-160/E
280921
3 0 0 55 160 Rear mounting Front IP65 P5-160/Z
280934
3 0 0 90 250 Flush mounting Front IP65 P5-250/E
280935
3 0 0 90 250 Rear mounting Front IP65 P5-250/Z
280948
3 0 0 110 315 Flush mounting Front IP65 P5-315/E
280949
3 0 0 110 315 Rear mounting Front IP65 P5-315/Z
280962
3+N 0 0 6.5 20 Surface mounting IP65 T0-2-8900/I1
0 1

207109
1
2
3
4
5
6
7
8

3+N 0 0 6.5 20 Flush mounting Front IP65 T0-2-8900/E


207398

3+N 0 0 6.5 20 Distribution board Front IP30 T0-2-8900/


mounting IVS
207403
3+N 0 0 6.5 20 Centre mounting Front IP65 T0-2-8900/EZ
207402

3+N 0 0 6.5 20 Rear mounting Front IP65 T0-2-8900/Z


207407

Notes 1) Enclosures with hard metric knock-outs


Ordering 7/23
Load current switches, ON/OFF switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P

Rotary switches, switch-disconnectors


Contact sequence Main Auxiliary Max. motor Rated Design Protection Part no. Price Std.
Front plate no. conducting contacts rating uninter- type Article no. see price pack
paths rupted list
ON
current
OFF
No. of poles AC-23A
FS 908

400/415 V
N/O N/O N/C 50-60 Hz
P Iu
kW A
On-Off switches
with black thumb grip and front plate
Without auxiliary contacts
3+N 0 0 13 25 Surface mounting IP65 P1-25/I2/N 1off
0 1

207303
1
2
3
4
5
6
N
N

3+N 0 0 13 25 Surface mounting IP65 P1-25/I2H/N1)


226901

3+N 0 0 13 25 Flush mounting Front IP65 P1-25/E/N


076845
3+N 0 0 13 25 Distribution board Front IP30 P1-25/IVS/N
mounting 083964
3+N 0 0 13 25 Centre mounting Front IP65 P1-25/EZ/N
079218
3+N 0 0 13 25 Rear mounting Front IP65 P1-25/Z/N
088710
3+N 0 0 15 32 Surface mounting IP65 P1-32/I2/N
207324
3+N 0 0 15 32 Surface mounting IP65 P1-32/I2H/N1)
227869

3+N 0 0 15 32 Flush mounting Front IP65 P1-32/E/N


093456
3+N 0 0 15 32 Distribution board Front IP30 P1-32/IVS/N
mounting 010402
3+N 0 0 15 32 Centre mounting Front IP65 P1-32/EZ/N
095829
3+N 0 0 15 32 Rear mounting Front IP65 P1-32/Z/N
015148
3+N 0 0 37 63 Surface mounting IP65 P3-63/I4/N
207360
3+N 0 0 37 63 Flush mounting Front IP65 P3-63/E/N
019894
3+N 0 0 37 63 Distribution board Front IP30 P3-63/IVS/N
mounting 022267
3+N 0 0 37 63 Rear mounting Front IP65 P3-63/Z/N
027013
3+N 0 0 50 100 Surface mounting IP65 P3-100/I5/N
207385
3+N 0 0 50 100 Flush mounting Front IP65 P3-100/E/N
031759
3+N 0 0 50 100 Distribution board Front IP30 P3-100/IVS/N
mounting 034132
3+N 0 0 50 100 Rear mounting Front IP65 P3-100/Z/N
038878
6 0 0 6.5 20 Surface mounting IP65 T0-3-8342/I1
0 1

207131
1
2
3
4
5
6
7
8
9
10
11
12

6 0 0 6.5 20 Flush mounting Front IP65 T0-3-8342/E


043624
6 0 0 6.5 20 Distribution board Front IP30 T0-3-8342/IVS
mounting 050743
6 0 0 6.5 20 Centre mounting Front IP65 T0-3-8342/EZ
045997
6 0 0 6.5 20 Rear mounting Front IP65 T0-3-8342/Z
055489
6 0 0 22 32 Surface mounting IP65 T3-3-8342/I2
207187
6 0 0 22 32 Flush mounting Front IP65 T3-3-8342/E
045225
6 0 0 22 63 Surface mounting IP65 T5B-3-8342/I4
207226
6 0 0 22 63 Flush mounting Front IP65 T5B-3-8342/E
092310
Notes 1) Enclosures with hard metric knock-outs
7/24 Ordering
Load current switches, ON/OFF switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Main con- Auxiliary Max. motor Rated Design Protection Part no. Price Std.
Front plate no. ducting contacts rating uninter- type Article no. see price pack
paths rupted list
ON
current
OFF
No. of AC-23A
FS 908 poles

400/415 V
50-60 Hz
N/O N/O N/C P Iu
kW A

On-Off switches
with black thumb grip and front plate
Without auxiliary contacts
8 0 0 6.5 20 Surface mounting IP65 T0-4-8344/I1 1 off
0 1

207139
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

8 0 0 6.5 20 Flush mounting Front IP65 T0-4-8344/E


014000
8 0 0 6.5 20 Distribution board Front IP30 T0-4-8344/IVS
mounting 014006

8 0 0 6.5 20 Centre mounting Front IP65 T0-4-8344/EZ


014002

8 0 0 22 63 Surface mounting IP65 T5B-4-8344/I4


207233
With auxiliary contacts
3 1 0 6.5 20 Surface mounting IP65 T0-2-15679/I1 1 off
0 1

207094
1
2
3
4
5
6
7
8

3 1 0 6.5 20 Flush mounting Front IP65 T0-2-15679/E


029387
3 1 0 6.5 20 Distribution board Front IP30 T0-2-15679/IVS
mounting 036506

3 1 0 6.5 20 Rear mounting Front IP65 T0-2-15679/Z


041252

3 1 1 6.5 20 Surface mounting IP65 T0-3-8901/I1


0 1

231941
1
2
3
4
5
6
7
8
9
10
11
12

3 1 1 6.5 20 Flush mounting Front IP65 T0-3-8901/E


231938
3 1 1 13 25 Surface mounting IP65 P1-25/I2H/HI111)
0 1

226899
1
2
3
4
5
6
13
14
21
22

3 1 1 15 32 Surface mounting IP65 P1-32/I2H/HI111)


227867
3 2 1 6.5 20 Surface mounting IP65 T0-3-15683/I1
0 1

207118
1
2
3
4
5
6
7
8
9
10
11
12

6 1 1 6.5 20 Surface mounting IP65 T0-4-15682/I1


0 1

207135
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

6 1 1 6.5 20 Flush mounting Front IP65 T0-4-15682/E


010405
6 1 1 22 32 Surface mounting IP65 T3-4-15682/I2
207190
6 1 1 22 32 Flush mounting Front IP65 T3-4-15682/E
023869
6 1 1 22 63 Surface mounting IP65 T5B-4-15682/I4
207229
6 1 1 22 63 Flush mounting Front IP65 T5B-4-15682/E
207424
6 1 1 22 63 Rear mounting Front IP65 T5B-4-15682/Z
207429

6 1 1 30 100 Surface mounting IP65 T5-4-15682/I5


207269

Notes 1) Enclosures with hard metric knock-outs


Ordering 7/25
Load current switches, changeover switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3, T5(B), T6, T8

Rotary switches, switch-disconnectors


Contact sequence Front Main Max. motor Rated Design Protection Part no. Price Std.
plate no. conducting rating uninter- type Article no. see price pack
paths rupted list
current
No. of poles AC-23A
400/415 V
50-60 Hz
N/O P Iu

kW A

Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
Group switches, mains transfer switches
1 6.5 20 Surface mounting IP65 T0-1-8210/I1 1 off
2 0 1

0
1 2
207076
FS 684 1 6.5 20 Flush mounting Front IP65 T0-1-8210/E
1
2
3
4

012742
1 6.5 20 Distribution board Front IP30 T0-1-8210/IVS
mounting 074440

1 6.5 20 Centre mounting Front IP65 T0-1-8210/EZ


048337

1 13 32 Flush mounting Front IP65 T3-1-8210/E


054718
1 22 63 Surface mounting IP65 T5B-1-8210/I4
207432
1 22 63 Flush mounting Front IP65 T5B-1-8210/E
094261
1 22 63 Rear mounting Front IP65 T5B-1-8210/Z
094258
2 6.5 20 Surface mounting IP65 T0-2-8211/I1
2 0 1

0
1 2
207102
FS 684
2 6.5 20 Flush mounting Front IP65 T0-2-8211/E
022234
1
2
3
4
5
6
7
8

2 6.5 20 Distribution board Front IP30 T0-2-8211/IVS


mounting 076813

2 6.5 20 Centre mounting Front IP65 T0-2-8211/EZ


053083

2 13 32 Surface mounting IP65 T3-2-8211/I2


207178
2 13 32 Flush mounting Front IP65 T3-2-8211/E
061837
2 13 32 Centre mounting Front IP65 T3-2-8211/EZ
003075

2 13 32 Rear mounting Front IP65 T3-2-8211/Z


064210
2 22 63 Surface mounting IP65 T5B-2-8211/I4
207220
2 22 63 Flush mounting Front IP65 T5B-2-8211/E
093094
2 22 63 Rear mounting Front IP65 T5B-2-8211/Z
093082
3 6.5 20 Surface mounting IP65 T0-3-8212/I1
2 0 1

0
1 2
207123
FS 684 3 6.5 20 Flush mounting Front IP65 T0-3-8212/E
1
2
3
4
5
6
7
8
9
10
11
12

029353
3 6.5 20 Distribution board Front IP30 T0-3-8212/IVS
mounting 079186

3 6.5 20 Centre mounting Front IP65 T0-3-8212/EZ


057829

3 6.5 20 Rear mounting Front IP65 T0-3-8212/Z


036473
7/26 Ordering
Load current switches, changeover switches
T0, T3, T5(B), T6, T8 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Front Main Max. motor Rated Design Protection Part no. Price Std. pack
plate con- rating uninter- type Article no. see price
no. ducting rupted list
paths current
No. of AC-23A
poles
400/415 V
50-60 Hz
N/O P Iu

kW A

Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
Group switches, mains transfer switches
3 13 32 Surface mounting IP65 T3-3-8212/I2 1 off
2 0 1

0
1 2
207183
FS 684 3 13 32 Flush mounting Front IP65 T3-3-8212/E
1
2
3
4
5
6
7
8
9
10
11
12

068956
3 13 32 Centre mounting Front IP65 T3-3-8212/EZ
003080

3 13 32 Rear mounting Front IP65 T3-3-8212/Z


071329
3 22 63 Surface mounting IP65 T5B-3-8212/I4
207223
3 22 63 Flush mounting Front IP65 T5B-3-8212/E
092386
3 22 63 Rear mounting Front IP65 T5B-3-8212/Z
092383
3 30 100 Flush mounting Front IP65 T5-3-8212/E
096466
3 30 100 Surface mounting IP65 T5-3-8212/I5
207266
3 30 100 Rear mounting Front IP65 T5-3-8212/Z
096464
0 3 45 125 Flush mounting Front IP65 T6-3-8212/E/HI12
1 0 2

1 2
214781
3 132 315 Flush mounting Front IP65 T8-3-8212/E/HI12
214782
1
2
3
4
5
6
7
8
9
10
11
12
101
102
103
104
105
106

4 6.5 20 Surface mounting IP65 T0-4-8213/I1


1 0 2

0
1 2
207136
FS 684 4 6.5 20 Flush mounting Front IP65 T0-4-8213/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

031726
4 6.5 20 Distribution board Front IP30 T0-4-8213/IVS
mounting 081559
4 6.5 20 Centre mounting Front IP65 T0-4-8213/EZ
062575

4 6.5 20 Rear mounting Front IP65 T0-4-8213/Z


043592
4 13 32 Surface mounting IP65 T3-4-8213/I2
207191
4 13 32 Flush mounting Front IP65 T3-4-8213/E
076075
4 13 32 Rear mounting Front IP65 T3-4-8213/Z
078448
4 22 63 Surface mounting IP65 T5B-4-8213/I4
207230
4 22 63 Flush mounting Front IP65 T5B-4-8213/E
092112
4 22 63 Rear mounting Front IP65 T5B-4-8213/Z
092109
4 30 100 Surface mounting IP65 T5-4-8213/I5
207270
4 30 100 Flush mounting Front IP65 T5-4-8213/E
096014
4 30 100 Rear mounting Front IP65 T5-4-8213/Z
096012
Ordering 7/27
Load current switches, changeover switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3, T5(B), T6, T8

Rotary switches, switch-disconnectors


Contact sequence Front Main con- Max. motor Rated Design Protection Part no. Price Std.
plate ducting rating uninter- type Article no. see price pack
no. paths rupted list
No. of AC-23A current
poles
400/415 V
50-60 Hz
N/O P Iu

kW A

Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
Group switches, mains transfer switches
4 6.5 20 Surface mounting IP65 T0-4-8294/I1 1 off
1 0 2

0
1 2 207138
FS 953 4 6.5 20 Flush mounting Front IP65 T0-4-8294/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

010371
4 6.5 20 Distribution board Front IP30 T0-4-8294/IVS
mounting 043594

4 13 32 Surface mounting IP65 T3-4-8294/I2


207193
4 13 32 Flush mounting Front IP65 T3-4-8294/E
002513
4 13 32 Rear mounting Front IP65 T3-4-8294/Z
004886

4 22 63 Surface mounting IP65 T5B-4-8294/I4


207232

4 22 63 Flush mounting Front IP65 T5B-4-8294/E


092084
4 22 63 Rear mounting Front IP65 T5B-4-8294/Z
092081

4 30 100 Surface mounting IP65 T5-4-8294/I5


207433
4 30 100 Flush mounting Front IP65 T5-4-8294/E
095986
4 30 100 Rear mounting Front IP65 T5-4-8294/Z
095984

Mains
NETZ
0 NOT-
STROM
4 13 32 Flush mounting Front IP65 T3-4-8902/E
0
Stand-by
215222
FS 161629 4 13 32 Flush mounting Front IP65 T3-4-8902/EZ
215223
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

4 13 32 Flush mounting IP65 T3-4-8902/I2


215224
4 13 32 Flush mounting Front IP65 T3-4-8902/Z
215225
4 22 63 Flush mounting Front IP65 T5B-4-8902/E
207430
4 22 63 Surface mounting IP65 T5B-4-8902/I4
207237

4 22 63 Rear mounting Front IP65 T5B-4-8902/Z


207431

4 30 100 Flush mounting Front IP65 T5-4-8902/E


207418
4 30 100 Surface mounting IP65 T5-4-8902/I5
207214
4 30 100 Rear mounting Front IP65 T5-4-8902/Z
207419
7/28 Ordering
Load current switches, changeover switches
T0, T3, T5(B), T6, T8 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Front Main con- Max. motor rating Rated Design Protection Part no. Price Std. pack
plate ducting uninter- type Article no. see price
no. paths rupted list
No. of AC-23A current
poles
400/415 V
50-60 Hz
N/O P Iu

kW A

Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
With spring-return from both directions to 0
1 6.5 20 Surface mounting IP65 T0-1-8214/I1 1 off
2

0
1 2
207077
0
1

FS 4011 1 6.5 20 Flush mounting Front IP65 T0-1-8214/E


1
2
3
4

019863
1 6.5 20 Distribution board Front IP30 T0-1-8214/IVS
mounting 045967
1 6.5 20 Centre mounting Front IP65 T0-1-8214/EZ
076815
1 6.5 20 Rear mounting Front IP65 T0-1-8214/Z
050720
2 6.5 20 Surface mounting IP65 T0-2-8215/I1
2

207103
0
1

2 6.5 20 Flush mounting Front IP65 T0-2-8215/E


1
2
3
4
5
6
7
8

022236
2 6.5 20 Distribution board Front IP30 T0-2-8215/IVS
mounting 048340
2 6.5 20 Centre mounting Front IP65 T0-2-8215/EZ
081561
3 6.5 20 Surface mounting IP65 T0-3-8216/I1
2

207434
0
1

3 6.5 20 Flush mounting Front IP65 T0-3-8216/E


1
2
3
4
5
6
7
8
9
10
11
12

024609
3 6.5 20 Centre mounting Front IP65 T0-3-8216/EZ
086307
3 13 32 Surface mounting IP65 T3-3-8216/I2
207184
3 13 32 Flush mounting Front IP65 T3-3-8216/E
023870
Without 0 (Off) position
Changeover switches
1 6.5 20 Surface mounting IP65 T0-1-8220/I1 1 off
1 2

1 2
207078
1 6.5 20 Flush mounting Front IP65 T0-1-8220/E
1
2
3
4

FS 943
031728
1 6.5 20 Distribution board Front IP30 T0-1-8220/IVS
mounting 055459
1 6.5 20 Centre mounting Front IP65 T0-1-8220/EZ
095799
1 6.5 20 Rear mounting Front IP65 T0-1-8220/Z
086312
2 6.5 20 Surface mounting IP65 T0-2-8221/I1
1 2

207104
2 6.5 20 Flush mounting Front IP65 T0-2-8221/E
1
2
3
4
5
6
7
8

038847
2 6.5 20 Distribution board Front IP30 T0-2-8221/IVS
mounting 057832
2 6.5 20 Centre mounting Front IP65 T0-2-8221/EZ
010372
2 22 32 Surface mounting IP65 T3-2-8221/I2
207180
2 22 32 Flush mounting Front IP65 T3-2-8221/E
045227
2 22 63 Surface mounting IP65 T5B-2-8221/I4
207221
2 22 63 Flush mounting Front IP65 T5B-2-8221/E
093047
Ordering 7/29
Load current switches, changeover switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3, T5(B), T6, T8

Rotary switches, switch-disconnectors


Contact sequence Main con- Max. Rated Design Protection Part no. Price Std.
Front plate no. ducting motor uninter- type Article no. see pack
1 2 paths rating rupted price
current list
FS 943
No. of AC-23A
poles
N/O 400/415 V
50-60 Hz
P Iu
kW A
Changeover switches
with black thumb grip and front plate
Without 0 (Off) position
Changeover switches
3 6.5 20 Surface mounting IP65 T0-3-8222/I1 1
1 2

207124
3 6.5 20 Flush mounting Front IP65 T0-3-8222/E
1
2
3
4
5
6
7
8
9
10
11
12

048339
3 6.5 20 Distribution board Front IP30 T0-3-8222/IVS
mounting 060205
3 6.5 20 Centre mounting Front IP65 T0-3-8222/EZ
015118
3 13 32 Flush mounting Front IP65 T3-3-8222/E
1 2

052346
3 22 32 Surface mounting IP65 T3-3-8222/I2
1
2
3
4
5
6
7
8
9
10
11
12

207185
3 22 63 Surface mounting IP65 T5B-3-8222/I4
207224
3 22 63 Flush mounting Front IP65 T5B-3-8222/E
092378
3 22 63 Rear mounting Front IP65 T5B-3-8222/Z
092375
4 6.5 20 Surface mounting IP65 T0-4-8223/I1
1 2

207137
4 6.5 20 Flush mounting Front IP65 T0-4-8223/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

050712
4 6.5 20 Distribution board Front IP30 T0-4-8223/IVS
mounting 062578
4 6.5 20 Centre mounting Front IP65 T0-4-8223/EZ
019864
4 6.5 20 Rear mounting Front IP65 T0-4-8223/Z
086315
4 13 32 Surface mounting IP65 T3-4-8223/I2
207192
4 13 32 Flush mounting Front IP65 T3-4-8223/E
059465
4 13 32 Rear mounting Front IP65 T3-4-8223/Z
061838
4 22 63 Surface mounting IP65 T5B-4-8223/I4
207231
4 22 63 Flush mounting Front IP65 T5B-4-8223/E
092108
4 22 63 Rear mounting Front IP65 T5B-4-8223/Z
092105
5 6.5 20 Flush mounting Front IP65 T0-5-8369/E
1 2

060204
5 22 32 Surface mounting IP65 T3-5-8369/I2
207536
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

5 22 32 Flush mounting Front IP65 T3-5-8369/E


066584
6 6.5 20 Flush mounting Front IP65 T0-6-8370/E
1 2

062577
6 6.5 20 Distribution board Front IP30 T0-6-8370/IVS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

mounting 067324
6 6.5 20 Centre mounting Front IP65 T0-6-8370/EZ
029356
6 22 32 Flush mounting Front IP65 T3-6-8370/E
073703
8 6.5 20 Flush mounting Front IP65 T0-8-8372/E
1 2

064950
8 6.5 20 Distribution board Front IP30 T0-8-8372/IVS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

mounting 069697
8 22 32 Flush mounting Front IP65 T3-8-8372/E
080822
7/30 Ordering
Load-current switch - Safety switch
P1, P3, T5(B) Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Main Auxiliary contacts Max. motor rating Rated Design Part no. Price Std. pack
con- uninter- Article no. see price
ducting rupted list
paths current
Front plate no. No. of AC-23A
poles
ON
400/415 V
OFF
50-60 Hz
FS 908 N/O N/O N/C P Iu

kW A

Safety switches with warning label

For use as Emergency-Stop device1)


3 0 0 13 25 Surface P1-25/I2-SI 1 off
0 1

mounting 207308
IP65
1
2
3
4
5
6

3 0 0 15 32 P1-32/I2-SI 1 off
207329
3 0 0 37 63 P3-63/I4-SI 1 off
207361
3 0 0 50 100 P3-100/I5-SI 1 off
207386
3+N 0 0 13 25 P1-25/I2-SI/N 1 off
0 1

207312
1
2
3
4
5
6
N
N

3+N 0 0 15 32 P1-32/I2-SI/N 1 off


207333
3+N 0 0 37 63 P3-63/I4-SI/N 1 off
207365
3+N 0 0 50 100 P3-100/I5-SI/N 1 off
207390
3 1 1 13 25 P1-25/I2-SI/HI11 1 off
0 1

207310
1
2
3
4
5
6
13
14
21
22

3 1 1 15 32 P1-32/I2-SI/HI11 1 off
207331
3 1 1 37 63 P3-63/I4-SI/HI11 1 off
207363
3 1 1 50 100 P3-100/I5-SI/HI11 1 off
207388
6 0 0 22 63 T5B-3-8342/I4-SI 1 off
0 1

207250
1
2
3
4
5
6
7
8
9
10
11
12

6 0 0 30 100 T5-3-8342/I5-SI 1 off


207447
6 1 1 22 63 T5B-4-15682/I4-SI 1 off
0 1

207254
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

6 1 1 30 100 T5-4-15682/I5-SI 1 off


207285
6 2 0 22 63 T5B-4-8903/I4-SI 1 off
0 1

207258
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

6 2 0 30 100 T5-4-8903/I5-SI 1 off


207289
Without Emergency-Stop
function2)
3 0 0 13 25 Surface P1-25/I2-SI-SW 1 off
0 1

mounting 207309
IP65
1
2
3
4
5
6

3 0 0 15 32 P1-32/I2-SI-SW 1 off
207330
3 0 0 37 63 P3-63/I4-SI-SW 1 off
207362

Notes 1) According to IEC/EN 60204-1, VDE 0113 Part 1


2) With black rotary handle and locking ring
Ordering 7/31
Load-current switch - Safety switch
http://catalog.moeller.net Moeller HPL0211-2007/2008 P1, P3, T5(B)

Rotary switches, switch-disconnectors


Contact sequence Main Auxiliary contacts Max. motor Rated Design Part no. Price Std. pack
conducting rating uninter- Article no. see price
paths rupted list
current
Front plate no. No. of poles AC-23A
ON
400/415 V
OFF
50-60 Hz
FS 908 N/O N/O N/C P Iu

kW A

Without Emergency-Stop
function
3+N 0 0 13 25 Surface P1-25/I2-SI/N-SW 1 off
0 1

mounting 207313
IP65
1
2
3
4
5
6
N
N

3+N 0 0 15 32 P1-32/I2-SI/N-SW 1 off


207334
3+N 0 0 50 100 P3-100/I5-SI/N-SW 1 off
207391
3 1 1 13 25 P1-25/I2-SI/HI11-SW 1 off
0 1

207311
1
2
3
4
5
6
13
14
21
22

3 1 1 15 32 P1-32/I2-SI/HI11-SW 1 off
207332
3 1 1 37 63 P3-63/I4-SI/HI11-SW 1 off
207364
3 1 1 50 100 P3-100/I5-SI/HI11-SW 1 off
207389
6 0 0 22 63 T5B-3-8342/I4-SI-SW 1 off
0 1

207251
1
2
3
4
5
6
7
8
9
10
11
12

6 1 1 22 63 T5B-4-15682/I4-SI-SW 1 off
0 1

207255
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

6 1 1 30 100 T5-4-15682/I5-SI-SW 1 off


207286
6 2 0 30 100 T5-4-8903/I5-SI-SW 1 off
207290

Engineering 4) The "ON" position can be locked using a padlock (after altering the handle) This
Maintenance, repair and safety switches all have the same electrical function. They is not permissable for switches with red/yellow handles.
are designed to safely isolate electrical installations (loads) from mains power
during maintenance and repair work and to ensure that a hazard does not arise Example:
which endangers personnel, machinery and production materials. Safety switch with load shedding and annunciation
Safety switches are main switches with an additional enclosure. Installed in the L1
immediate vicinity of the motor or the electrical load they act as switch- L2
L3
disconnectors for that load. It makes possible work without danger according to DIN N
EN 50110/VDE 0105. This is particularly important if there is any danger of the main
switch being inadvertently operated. FAZ-
F1 F0 B4/1-HS
Application
1 3 5 95
By securing the switch in the OFF position with his own padlock (up to 3 can be
Q11 F2
fitted), the fitter/electrician can protect himself against the possibility of any other 96
2 4 6
person switching the machine on. Maintenance switches are merely additional, 21
enclosed main switches with a padlocking facility. F2 O
Enclosed main switch with padlock interlock 22
a 7/10
13 13
a 7/30
I Q11
14 14
Features
Safety switches are housed in insulated enclosures and bear the inscription
Safety switch on a bright orange label. 1 3 5 7 9 11

With special red handle and yellow locking ring for Emergency_Stop use Q1
according to STOP category O IEC/EN 60204/VDE 0113. 2 4 6 8 10 12
If the switch is not usable for Emergency_Stop both parts are black (partno. suffix U V W

"SW")
The cover and handle can be interlocked by fitting a padlock. A1
P1 P2 Q11
M A2
Selection 3
Switches must be selected according to the following criteria:
1) according to motor switching capacity, when the switch is fitted in so that the
operator may use it for operational ON and OFF switching.
2) The rating data always applies for 3 poles. When the motor rating is divided
between 6 poles, such as for star-delta starting, a 6-pole switch can be used to
control 1.73 times the rated power.
3) If the switch has a load-shedding contact (LA), you can select the appropriate
switch according to the uninterrupted current. The load-shedding contact is an
auxiliary contact, which is closed in the ON position and opens early when switching
off, so that a contactor located in the circuit takes over the switching capacity and
the maintenance/safety switch operates at zero load. When switching on, the load-
shedding contact closes later than or at the same time as the main contacts. With P
and T switches this is the N/O auxiliary contact.
7/32 Ordering
Load current switch - reversing switch
T0, T3, T5B Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Front Main Max. motor Rated Design Protection Part no. Price Std. pack
plate conducting rating uninterrupted type Article no. see price
no. paths current list

No. of AC-23A
poles
N/O 400/415 V
50-60 Hz
P Iu
kW A

Reversing switches with 0 (Off) position


with black thumb grip and front plate
Without spring-return

0 2 6.5 20 Surface mounting IP65 T0-2-8400/I1 1 off


1 0 2

1 2
207111
FS 684
Flush mounting Front IP65 T0-2-8400/E
053079
1
2
3
4
5
6
7
8

Distribution board Front IP30 T0-2-8400/IVS


mounting 060198
22 32 Surface mounting IP65 T3-2-8400/I2
207181
Flush mounting Front IP65 T3-2-8400/E
073695
63 Surface mounting IP65 T5B-2-8400/I4
207222
Flush mounting Front IP65 T5B-2-8400/E
092918
0 3 6.5 20 Surface mounting IP65 T0-3-8401/I1 1 off
1 0 2

1 2
207132
FS 684
Flush mounting Front IP65 T0-3-8401/E
091047
1
2
3
4
5
6
7
8
9
10

Distribution board Front IP30 T0-3-8401/IVS


mounting 098166
Centre mounting Front IP65 T0-3-8401/EZ
093420
Rear mounting Front IP65 T0-3-8401/Z
010366
22 32 Surface mounting IP65 T3-3-8401/I2
207188
Flush mounting Front IP65 T3-3-8401/E
030992
Centre mounting Front IP65 T3-3-8401/EZ
000694
Rear mounting Front IP65 T3-3-8401/Z
035739
63 Surface mounting IP65 T5B-3-8401/I4
207227
Flush mounting Front IP65 T5B-3-8401/E
092296
Rear mounting Front IP65 T5B-3-8401/Z
092293
With spring-return from both directions to 0

3 6.5 20 Surface mounting IP65 T0-3-8228/I1 1 off


2

0
1 2
207125
0
1

FS 4011
Flush mounting Front IP65 T0-3-8228/E
015112
1
2
3
4
5
6
7
8
9
10

Centre mounting Front IP65 T0-3-8228/EZ


048334
22 32 Surface mounting IP65 T3-3-8228/I2 1 off
207186
Ordering 7/33
Load current switches, (reversing) star-delta switches, (reversing) multi-speed switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3, T5(B)

Rotary switches, switch-disconnectors


Contact sequence Front Main Max. motor Rated Design Protection Part no. Price Std.
plate conducting rating uninter- type Article no. see price pack
no. paths rupted list
No. of AC-23A current
poles
N/O 400/415 V
50-60 Hz
P Iu
kW A
Star-delta switches
with black thumb grip and front plate
3 6.5 20 Surface IP65 T0-4-8410/I1 1 off
0 y d

Y
0
mounting 207140
FS 635 Flush mounting Front IP65 T0-4-8410/E
024604
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Distribution Front IP30 T0-4-8410/IVS


board mounting 064945

Centre Front IP65 T0-4-8410/EZ


mounting 053080

Rear mounting Front IP65 T0-4-8410/Z


083929

22 32 Surface IP65 T3-4-8410/I2


mounting 207195
Flush mounting Front IP65 T3-4-8410/E
009657
Centre Front IP65 T3-4-8410/EZ
mounting 000721

Rear mounting Front IP65 T3-4-8410/Z


012030

63 Surface IP65 T5B-4-8410/I4


mounting 207234
Flush mounting Front IP65 T5B-4-8410/E
092052
Reversing Star-delta switches
with black thumb grip and front plate
Two-way switches
3 6.5 20 Flush mounting Front IP65 T0-5-15876/E 1 off
d y 0 y d

0
Y Y
000893
FS 638 22 32 Surface IP65 T3-5-15876/I2
mounting 207537
Flush mounting Front IP65 T3-5-15876/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

016776
Rear mounting Front IP65 T3-5-15876/Z
019149

63 Flush mounting Front IP65 T5B-5-15876/E


d y 0 y d

0
Y Y
214785
FS 4017
Flush mounting Front IP65 T5B-5-15876/Z
214786
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Reversing multi-speed switches


with black thumb grip and front plate
Two-speed, two directions, for one tapped winding
0 3 6.5 20 Flush mounting Front IP65 T0-6-15866/E 1 off
2 1 0 1 2

1 1
2 2 055460
Centre Front IP65 T0-6-15866/EZ
FS 629
mounting 012747

Rear mounting Front IP65 T0-6-15866/Z


067326
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

22 32 Flush mounting Front IP65 T3-6-15866/E


054744
0 3 22 63 Flush mounting Front IP65 T5B-7-15866/E 1 off
2 1 0 1 2

1 1
2 2
214788
FS 441
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
7/34 Ordering
Control switch, multi-speed switch
T0, T3, T5B Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Front Main con- Max. motor Rated Design Protec- Part no. Price Std.
plate ducting rating uninterrupted tion type Article no. see price pack
no. paths current list
No. of AC-23A
poles

400/415 V
50-60 Hz
N/O P Iu

kW A

Multi-speed switches
with black thumb grip and front plate
Two-speed, non reversing, for 2 separate windings
1 3 6.5 20 Surface mounting IP65 T0-3-8451/I1 1 off
0 1 2

0 2
207133
FS 644
Flush mounting Front IP65 T0-3-8451/E
038849
1
2
3
4
5
6
7
8
9
10
11
12

Distribution board Front IP30 T0-3-8451/IVS


mounting 026985

Centre mounting Front IP65 T0-3-8451/EZ


083936

22 32 Surface mounting IP65 T3-3-8451/I2


207189
Flush mounting Front IP65 T3-3-8451/E
028641

2-speed, 1 directions, for tapped winding


1 3 6.5 20 Surface mounting IP65 T0-4-8440/I1 1 off
0 1 2

0 2
207141
FS 644
Flush mounting Front IP65 T0-4-8440/E
041222
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Distribution board Front IP30 T0-4-8440/IVS


mounting 029358

Centre mounting Front IP65 T0-4-8440/EZ


088682

Rear mounting Front IP65 T0-4-8440/Z


048342

22 32 Surface mounting IP65 T3-4-8440/I2


207196
Flush mounting Front IP65 T3-4-8440/E
035760

63 Flush mounting Front IP65 T5B-4-8440/E


092032

0 3 6.5 20 Surface mounting IP65 T0-4-8441/I1 1 off


1 0 2

1 2
207142
FS 684
Flush mounting Front IP65 T0-4-8441/E
043595
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Distribution board Front IP30 T0-4-8441/IVS


mounting 031731

22 32 Surface mounting IP65 T3-4-8441/I2


207197
Flush mounting Front IP65 T3-4-8441/E
042879

63 Rear mounting Front IP65 T5B-4-8441/Z


092025
Ordering 7/35
Control switch, step switch
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0

Rotary switches, switch-disconnectors


Contact sequence Front plate no. No. of Design Protection Part no. Price Std. pack
poles type Article no. see price
list

Step switches
With black thumb-grip and grey front plate
One contact closed per step
(without overlap)
With 0 (Off) position
2 1 Surface mounting IP 65 T0-1-8240/I1
0 1 2

1
0 207079
FS 418 Flush mounting Front IP 65 T0-1-8240/E
034105
1
2
3
4

Centre mounting Front IP 65 T0-1-8240/EZ


043597
1 Surface mounting IP 65 T0-2-8241/I1
0 1 2 3

2
1 3
0 207107
FS 420 Flush mounting Front IP 65 T0-2-8241/E
050716
1
2
3
4
5
6

Distribution board Front IP 30 T0-2-8241/IVS


mounting 057835
Centre mounting Front IP 65 T0-2-8241/EZ
053089
2 1 Surface mounting IP 65 T0-2-8242/I1
0 1 2 3 4

1 3
0 4 207108
FS 422 Flush mounting Front IP 65 T0-2-8242/E
067327
1
2
3
4
5
6
7
8

Distribution board Front IP 30 T0-2-8242/IVS


mounting 074446
Centre mounting Front IP 65 T0-2-8242/EZ
069700
2 1 Surface mounting IP 65 T0-3-8243/I1
0 1 2 3 4 5

1 3
0
5
4
207128
FS 424 Flush mounting Front IP 65 T0-3-8243/E
081565
Distribution board Front IP 30 T0-3-8243/IVS
1
2
3
4
5
6
7
8
9
10

mounting 088684
Centre mounting Front IP 65 T0-3-8243/EZ
083938
2 1 Flush mounting Front IP 65 T0-3-8244/E
0 1 2 3 4 5 6

1 3
0
5
4 095803
6
Distribution board Front IP 30 T0-3-8244/IVS
FS 426
mounting 012749
Centre mounting Front IP 65 T0-3-8244/EZ
098176
1
2
3
4
5
6
7
8
9
10
11
12

2 3 Surface mounting IP 65 T0-3-8280/I1


0 1 2

1
0 207130
FS 418 Flush mounting Front IP 65 T0-3-8280/E
1
2
3
4
5
6
7
8
9
10
11
12

034106
Centre mounting Front IP 65 T0-3-8280/EZ
036479
2 3 Flush mounting Front IP 65 T0-5-8281/E
0 1 2 3

1 3
0 048344
FS 420
Distribution board Front IP 30 T0-5-8281/IVS
mounting 055463
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Centre mounting Front IP 65 T0-5-8281/EZ


050717
Rear mounting Front IP 65 T0-5-8281/Z
057836
2 3 Flush mounting Front IP 65 T0-6-8282/E
0 1 2 3 4

1 3
0 4
062582
FS 422
Distribution board Front IP 30 T0-6-8282/IVS
mounting 069701
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Centre mounting Front IP 65 T0-6-8282/EZ


064955
7/36 Ordering
Control switch, step switch
T0 Moeller HPL0211-2003 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Front plate no. No. of Design Protection type Part no. Price Std. pack
poles Article no. see price list

Step switches
With black thumb-grip and grey front plate
One contact closed per step
(without overlap)
Without 0 (Off) position
1 Surface mounting IP65 T0-1-8220/I1 1 off
1 2

1 2
207078
1 Flush mounting Front IP65 T0-1-8220/E 1 off
1
2
3
4

FS 943
031728
1 Distribution board Front IP30 T0-1-8220/IVS 1 off
mounting 055459
1 Centre mounting Front IP65 T0-1-8220/EZ 1 off
095799
1 Rear mounting Front IP65 T0-1-8220/Z 1 off
086312
3 1 Surface mounting IP 65 T0-2-8230/I1 1 off
1 2 3

2
1
207105
FS 404 1 Flush mounting Front IP 65 T0-2-8230/E 1 off
1
2
3
4
5
6

088685
1 Distribution board Front IP 30 T0-2-8230/IVS 1 off
mounting 095804
1 Centre mounting Front IP 65 T0-2-8230/EZ 1 off
091058
2 3 1 Surface mounting IP 65 T0-2-8231/I1 1 off
1 2 3 4

1 4
207106
FS 606 1 Flush mounting Front IP 65 T0-2-8231/E 1 off
012750
1
2
3
4
5
6
7
8

1 Distribution board Front IP 30 T0-2-8231/IVS 1 off


mounting 019869
1 Centre mounting Front IP 65 T0-2-8231/EZ 1 off
015123
3 1 Flush mounting Front IP 65 T0-3-8232/E 1 off
1 2 3 4 5

2 4
1 5 026988
FS 408
1 Distribution board Front IP 30 T0-3-8232/IVS 1 off
mounting 034107
1 Centre mounting Front IP 65 T0-3-8232/EZ 1 off
1
2
3
4
5
6
7
8
9-
10

029361
3 1 Surface mounting IP 65 T0-3-8233/I1 1 off
1 2 3 4 5 6

2 4
1
6
5
207127
FS 410 1 Flush mounting Front IP 65 T0-3-8233/E 1 off
041226
1 Distribution board Front IP 30 T0-3-8233/IVS 1 off
1
2
3
4
5
6
7
8
9
10
11
12

mounting 048345
1 Centre mounting Front IP 65 T0-3-8233/EZ 1 off
043599
3 2 Flush mounting Front IP 65 T0-4-8251/E 1 off
1 2 3 4

2 4
1 013971
FS 406
2 Centre mounting Front IP 65 T0-4-8251/EZ 1 off
013972
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

3 Surface mounting IP65 T0-3-8222/I1 1 off


1 2

1 2
207124
3 Flush mounting Front IP65 T0-3-8222/E 1 off
1
2
3
4
5
6
7
8
9
10
11
12

FS 943
048339
3 Distribution board Front IP30 T0-3-8222/IVS 1 off
mounting 060205
3 Centre mounting Front IP65 T0-3-8222/EZ 1 off
015118
3 3 Flush mounting Front IP 65 T0-5-8270/E 1 off
1 2 3

2
1
091059
FS 404 3 Distribution board Front IP 30 T0-5-8270/IVS 1 off
mounting 098178
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

3 Centre mounting Front IP 65 T0-5-8270/EZ 1 off


093432
3 3 Flush mounting Front IP 65 T0-6-8271/E 1 off
1 2 3 4

2 4
1 015124
FS 406
3 Centre mounting Front IP 65 T0-6-8271/EZ 1 off
017497
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Ordering 7/37
Control switch, ON-OFF switches, changeover switches, Hand/Auto switches
http://catalog.moeller.net Moeller HPL0211-2003

Rotary switches, switch-disconnectors


Contact sequence Front plate no. No. of Design Protection type Part no. Price Std. pack
poles Article no. see price list

On-Off switches
With black thumb-grip and grey front plate
One contact closed per step
(without overlap)
1 Flush mounting Front IP 65 T0-1-15401/E 1 off
0 1

0
1
038854
1
2

FS 415
1 Centre mounting Front IP 65 T0-1-15401/EZ 1 off
041227
1 Surface mounting IP 65 T0-1-15401/I1 1 off
207067
1 Distribution board Front IP30 T0-1-15401/IVS 1 off
mounting 045973
2 Flush mounting Front IP 65 T0-1-15402/E 1 off
0 1

053092
1
2
3
4

2 Centre mounting Front IP 65 T0-1-15402/EZ 1 off


055465
2 Surface mounting IP 65 T0-1-15402/I1 1 off
207068
2 Distribution board Front IP30 T0-1-15402/IVS 1 off
mounting 060211
3 Flush mounting Front IP 65 T0-2-15403/E 1 off
0 1

067330
1
2
3
4
5
6

3 Centre mounting Front IP 65 T0-2-15403/EZ 1 off


069703
3 Distribution board Front IP30 T0-2-15403/IVS 1 off
mounting 074449
4 Flush mounting Front IP 65 T0-2-15404/E 1 off
0 1

081568
1
2
3
4
5
6
7
8

4 Centre mounting Front IP 65 T0-2-15404/EZ 1 off


083941
Changeover switches
With black thumb-grip and grey front plate
One contact closed per step
(without overlap)
0 1 Flush mounting Front IP 65 T0-1-15421/E 1 off
2 0 1

2 1
095806
FS 429
1 Centre mounting Front IP 65 T0-1-15421/EZ 1 off
098179
1
2
3
4

1 Surface mounting IP 65 T0-1-15421/I1 1 off


207069
1 Distribution board Front IP30 T0-1-15421/IVS 1 off
mounting 012752
2 Flush mounting Front IP 65 T0-2-15422/E 1 off
2 0 1

019871
2 Distribution board Front IP30 T0-2-15422/IVS 1 off
mounting 026990
1
2
3
4
5
6
7
8

2 Centre mounting Front IP 65 T0-2-15422/EZ 1 off


022244
2 Rear mounting Front IP 65 T0-2-15422/Z 1 off
029363
3 Surface mounting IP 65 T0-3-15423/I1 1 off
2 0 1

207114
3 Flush mounting Front IP 65 T0-3-15423/E 1 off
1
2
3
4
5
6
7
8
9
10
11
12

034109
Hand/Auto switches
With 0 (Off) position
Without spring-return
AUTO 0
HAND AUTO
1 Surface mounting IP65 T0-1-15431/I1 1 off
0
HAND
207070
FS 1401 Flush mounting Front IP 65 T0-1-15431/E
1
2
3
4

019872
Distribution board IP65 T0-1-15431/IVS
mounting 026991
Centre mounting Front IP 65 T0-1-15431/EZ
022245
Rear mounting Front IP 65 T0-1-15431/Z
029364
7/38 Ordering
Control switch - hand/auto switch
T0 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price list

Hand/Auto switches
With 0 (Off) position
Without spring- AUTO 0
HAND AUTO
2 Surface mounting IP65 T0-2-15432/I1 1 off
0
return HAND
207091
FS 1401 Flush mounting Front IP 65 T0-2-15432/E
1
2
3
4
5
6
7
8

034110
Distribution board IP65 T0-2-15432/IVS
mounting 041229
Centre mounting Front IP 65 T0-2-15432/EZ
036483
Rear mounting Front IP 65 T0-2-15432/Z
043602
AUTO 0
HAND AUTO
3 Surface mounting IP65 T0-3-15433/I1 1 off
0
HAND
207115
FS 1401 Flush mounting Front IP 65 T0-3-15433/E
1
2
3
4
5
6
7
8
9
10
11
12

048348
Distribution board IP65 T0-3-15433/IVS
mounting 055467
Centre mounting Front IP 65 T0-3-15433/EZ
050721
Rear mounting Front IP 65 T0-3-15433/Z
057840
With spring-return AUTO 0
HAND AUTO
1 Surface mounting IP65 T0-1-15434/I1 1 off
0
from HAND HAND
207071
FS 1414000 Flush mounting Front IP 65 T0-1-15434/E
1
2
3
4

062586
Centre mounting Front IP 65 T0-1-15434/EZ
018053
AUTO 0
HAND AUTO
2 Layout IP65 T0-2-15435/I1 1 off
0
HAND
218971
FS 1414000 Flush mounting Front IP 65 T0-2-15435/E
1
2
3
4
5
6
7
8

003191
With spring-return START
0
1 Surface mounting IP65 T0-2-15907/I1 1 off
HAND
from START 0
AUTO HAND

START
207095
AUTO

FS 1413890
Flush mounting Front IP65 T0-2-15907/E
1
2
3
4
5
6
7
8

066931
Centre mounting Front IP65 T0-2-15907/EZ
069304
Rear mounting Front IP65 T0-2-15907/Z
078796
Without 0 (Off) position
Without spring- AUTO HAND AUTO 1 Surface mounting IP65 T0-1-15451/I1 1 off
HAND
return 207072
FS 19334 Flush mounting Front IP65 T0-1-15451/E
1
2
3
4

076824
Distribution board Front IP30 T0-1-15451/IVS
mounting 083943
Centre mounting Front IP65 T0-1-15451/EZ
079197
Rear mounting Front IP65 T0-1-15451/Z
086316
AUTO HAND AUTO 2 Flush mounting Front IP65 T0-2-15452/E 1 off
HAND
091062
FS 19334 Distribution board Front IP30 T0-2-15452/IVS
1
2
3
4
5
6
7
8

mounting 098181
Centre mounting Front IP65 T0-2-15452/EZ
093435
AUTO HAND AUTO 3 Flush mounting Front IP65 T0-3-15453/E 1 off
HAND
015127
FS 19334 Distribution board Front IP30 T0-3-15453/IVS
1
2
3
4
5
6
7
8
9
10
11
12

mounting 022246
Centre mounting Front IP65 T0-3-15453/EZ
017500
Rear mounting Front IP65 T0-3-15453/Z
024619
Ordering 7/39
Control switch - ON switches, universal control switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0

Rotary switches, switch-disconnectors


Contact sequence Front plate Pole Design Protection Part no. Price Std. pack
no. type Article no. see price
list

On switches
with black thumb grip and front plate
ON spring-return switches (make contact)
Spring-return in position 1
1 Flush mounting Front IP65 T0-1-15321/E 1 off
I 1

1
086317
1
2

FS 4721
Centre mounting Front IP65 T0-1-15321/EZ
088690
2 Flush mounting Front IP65 T0-1-15322/E
I 1

010382
1
2
3
4

3 Surface mounting IP65 T0-2-15323/I1


I 1

207087
1
2
3
4
5
6

Flush mounting Front IP65 T0-2-15323/E


024620
On-Off spring-return switches
Spring-return in positions 0 and 1
1 Flush mounting Front IP65 T0-1-15366/E
1

0 1
081572
I
0

FS 456
Centre mounting Front IP65 T0-1-15366/EZ
083945
1
2
3
4

ON-OFF spring-return switch


Spring-return in START position
START 1 1 Surface mounting IP65 T0-1-15511/I1
1
0
0 START
207073
FS 147767 Flush mounting Front IP65 T0-1-15511/E
1
2
3
4

019875
Centre mounting Front IP65 T0-1-15511/EZ
022248
Rear mounting Front IP65 T0-1-15511/Z
029367
START 2 Surface mounting IP65 T0-2-15512/I1
1
0
207093
Flush mounting Front IP65 T0-2-15512/E
1
2
3
4
5
6
7
8

034113
Centre mounting Front IP65 T0-2-15512/EZ
036486
START
1
0
2
see K Flush mounting Front IP65 T0-2-8177/E
2
0
START START 115 015130
1
START FS 140660 Centre mounting Front IP65 T0-2-8177/EZ
017503
Rear mounting Front IP65 T0-2-8177/Z
024622
1
2
3
4
5
6
7
8

Universal control switches


With black thumb-grip and grey front plate

1 contact closed in each position


Additionally 1 contact closed in position 0 and 1
Additionally 1 contact closed in position 0 and 2
Additionally 1 contact closed in position 0 and 3
Stay-put switches with 3 positions
0 Flush mounting Front IP65 T0-3-15391/E 1 off
2 0 1

2 1
029365
Centre mounting Front IP65 T0-3-15391/EZ
1
2
3
4
5
6
7
8
9
10
11
12

FS 429
031738
Spring-return from positions 1 and 2
Flush mounting Front IP65 T0-3-15394/E
1

0
2 1
072079
0
2

FS 458
Distribution board mounting Front IP30 T0-3-15394/IVS
1
2
3
4
5
6
7
8
9
10
11
12

079198
Centre mounting Front IP65 T0-3-15394/EZ
074452
7/40 Ordering
Control switches, instrument selector switches
T0 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact sequence Front plate Pole Design Protection Part no. Price Std. pack
no. type Article no. see price
list

Coding switches
With black thumb-grip and grey front plate
With complete rotation in both directions
1
2 3 4
5
Dual BCD CODE Flush mounting Front IP65 T0-4-15602/E 1 off
0
7
6 029368
0 1 2 3 4 5 6 7 8 9

9 8
Centre mounting Front IP65 T0-4-15602/EZ
FS 312
031741
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Series switches
With black thumb-grip and grey front plate
With 0 (Off) position (heater switches)
1 2 1 Flush mounting Front IP65 T0-1-91/E
0 1 2

0
072082
FS 614
1
2
3
4

Voltmeter selector switches


With black thumb-grip and grey front plate
L3-N
L2-N
L1-N L3-N
3 x phase to N with 0 (Off) Flush mounting Front IP65 T0-2-15921/E 1 off
L2-N
0
position 067337
L1-N
FS 1410757
0
1
2
3
4
5
6
7
8

L3-N L1-L2
0 L1-N 3 x phase to phase + 3 x phase Flush mounting Front IP65 T0-3-8007/E 1 off
L2-N
L1-N
L2-L3
L3-L1
L2-N
L3-N
to N with 0 (Off) position 095813
0
L1-L2 FS 1410759
Distribution board Front IP30 T0-3-8007/IVS
L2-L3 mounting 012759
L3-L1

Centre mounting Front IP65 T0-3-8007/EZ


098186
1
2
3
4
5
6
7
8
9
10
11
12

Rear mounting Front IP65 T0-3-8007/Z


015132

L3-N
L2-N L1-L2
L2-L3
L3-L1
3 x phase to phase + 3 x phase Flush mounting Front IP65 T0-3-15924/E 1 off
L1-N L3-N L1-N
to N Without 0 position with 019878
L3-L1
L2-N
complete rotation in both Distribution board Front IP30 T0-3-15924/IVS
L2-L3 FS 164721
L1-L2
directions mounting 026997

Centre mounting Front IP65 T0-3-15924/EZ


022251
1
2
3
4
5
6
7
8
9
10
11
12

L3-L1
L2-L3
L1-L2 L3-L1
3 x phase to phase with 0 (Off) Flush mounting Front IP65 T0-2-15920/E 1 off
L2-L3
0
position 038861
L1-L2
FS 1410755
Distribution board Front IP30 T0-2-15920/IVS
0 mounting 029452

Centre mounting Front IP65 T0-2-15920/EZ


041234
1
2
3
4
5
6
7
8

Rear mounting Front IP65 T0-2-15920/Z


048353

L3-L1
L2-L3
L1-L2 L3-L1
3 x phase to phase without 0 Flush mounting Front IP65 T0-2-15922/E 1 off
L2-L3
(Off) position 053099
L1-L2 FS 164854 Centre mounting Front IP65 T0-2-15922/EZ
055472
1
2
3
4
5
6
7
8

Ammeter selector switches


With black thumb-grip and grey front plate
With complete rotation in both directions
Measurement via current transformers
0 With 0 (Off) position Flush mounting Front IP65 T0-3-8048/E 1 off
L3 L1
034116
L2

FS 9440
Distribution board Front IP30 T0-3-8048/IVS
mounting 041235

Centre mounting Front IP65 T0-3-8048/EZ


1
2
3
4
5
6
7
8
9
10
11
12

036489
Ordering 7/41
Switches with locking mechanism
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, P1

Rotary switches, switch-disconnectors


Contact Front No. of Max. motor Rated Design Protection Part no. Price Std. pack
sequence plate no. poles rating uninterrupted type Article no. see price
current list
AC-23A
400/415 V
50-60 Hz

P Iu

kW A

Panic switch
Cylinder lock SVA
Key withdrawable in position 0 and 1
If the key is withdrawn in position 1 the switch can be switched off but not on again without the key.

With Emergency-Stop function


According to IEC/EN 60204-1, VDE 0113 Part1 with red thumb-grip and yellow front plate
1 3 6.5 20 Layout IP65 T0-2-1/I1/SVA(S)-RT 1 off
0 1

0 207085
1
2
3
4
5
6

3 13 25 ON
Layout IP65 P1-25/I2/SVA(S)-RT 1 off
FS 908 GE OFF 207306

3 6.5 20 Flush IP65 T0-2-1/E/SVA(S)-RT 1 off


mounting 228291

3 15 32 Flush IP65 P1-32/E/SVA(S)-RT 1 off


mounting 050971

Without Emergency-Stop function


with black thumb grip and front plate
ON
3 6.5 20 Layout IP65 T0-2-1/I1/SVA(S) 1 off
0 1

OFF 207084
1
2
3
4
5
6

FS 908 3 13 25 ON
Layout IP65 P1-25/I2/SVA(S) 1 off
OFF 207305

3 6.5 20 Flush IP65 T0-2-1/E/SVA(S) 1 off


mounting 050977

3 15 32 Flush IP65 P1-32/E/SVA(S) 1 off


mounting 044977

Padlocking feature SVC


Interlocking slide with lock lockable in positions 0 and 1
If the interlocking slide is interlocked with lock in position 1 the switch can be switched off but not on again without
removing the lock. Lockable with max. 3 padlocks.
With Emergency-Stop function
According to IEC/EN 60204-1, VDE 0113 Part1 with red thumb-grip and yellow front plate
1 3 6.5 20 Layout IP65 T0-2-1/I1/SVC(S)-RT 1 off
0 1

0 207086
1
2
3
4
5
6

FS 908 GE

Notes
E
D F
C G
B 330
0
30 H
300 60
315 45
A 270 90 J
225 135
240 120
210 150
R 180 K
Q L
P M
N
Code letters for lockable switch positions
Letter S for panic lock with FS908GE
7/42 Ordering
Switches with locking mechanism
T0, P1 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Contact Front No. of Max. motor Rated Product Design Protection Part no. Price Std. pack
sequence plate no. poles rating uninterrupted view type Article no. see price
current list
AC-23A
400/415 V
50-60 Hz

P Iu

kW A

On-Off switch
with black thumb grip and front plate
Key can only be withdrawn in position 0 (Pos A)
Without Emergency-Stop function
Cylinder lock SVA
ON
2 6.5 20 Layout IP65 T0-1-102/I1/S 1 off
0 1

OFF 207063
1
2
3
4

FS 908

ON
2 6.5 20 Flush IP65 T0-1-102/EZ/S 1 off
0 1

OFF mounting 014933


1
2
3
4

FS 908

Key operation ST-0, IP53


ON
3 6.5 20 Layout IP65 T0-2-1/I1/SVA(A) 1 off
0 1

OFF 207083
1
2
3
4
5
6

FS 908 3 13 25 ON
Layout IP65 P1-25/I2/SVA(A) 1 off
OFF 207304

3 6.5 20 Flush IP65 T0-2-1/E/SVA(A) 1 off


mounting 050976

3 13 25 Flush IP65 P1-25/E/SVA(A) 1 off


mounting 050965

3 6.5 20 Rear IP65 T0-2-1/Z/SVA(A) 1 off


mounting 050978
ON

OFF

Notes
E
D F
C G
B 330
0
30 H
300 60
315 45
A 270 90 J
225 135
240 120
210 150
R 180 K
Q L
P M
N
Code letters for lockable switch positions
Letter S for panic lock with FS908GE
Ordering 7/43
Main switch assembly kits, thumb-grips, maintenance keys
http://catalog.moeller.net Moeller HPL0211-2007/2008 SVB-...-T0(P3), KNB-...-T0(P3)

Rotary switches, switch-disconnectors


For use with Part no. Price Std. pack Notes
Article no. see price
list

Main switch assembly kits


Padlocking feature, exclusively for main switches
Admissible on T0 up to 4 contact units
Admissible on T3 up to 6 contact units
With red rotary as Emergency-Stop T0-.../E, .../Z, .../I1 SVB-T0 1 off for interlocking the 0 position
handle and yellow device according to T3-.../E, .../Z, .../I2 057892 for switches with positions 0 -
locking ring IEC/EN 60204-1, P1-.../E, .../Z, .../I2 I at 90
VDE 0113 Part 1 T5B-.../E, .../Z, .../I4 SVB-P3 1 off Switching angle as front plate
T5-.../E, .../Z, .../I5 052999 FS908
P3-63/E, .../Z, .../I4 Lockable with max. 3
P3-100/E, .../Z, .../I5 padlocks

With black rotary Without Emergency- T0-.../E, .../Z, .../I1 SVB-SW-T0 1 off for interlocking the 0 position
handle and black Stop function T3-.../E, .../Z, .../I2 060265 for interlocking the I position
locking ring P1-.../E, .../Z, .../I2 when required
T5B-.../E, .../Z, .../I4 SVB-SW-P3 1 off Lockable with max. 3
T5-.../E, .../Z, .../I5 062491 padlocks
P3-63/E, .../Z, .../I4
P3-100/E, .../Z, .../I5
Main switch assembly kits with PE terminal and N terminal
With red rotary as Emergency-Stop T0-.../E, .../Z V/EA/SVB-T0 1 off For conversion of T.../E flush
handle and yellow device according to T3-.../E, .../Z 062638 mounting switches with front
locking ring IEC/EN 60204-1, T5(B)-.../E, .../Z V/EA/SVB-T5 1 off plate FS908 into T.../EA/SVB...
VDE 0113 Part 1 045065 flush mounting main
switches.
For conversion of T.../Z rear
mounting switches (with front
With black rotary Without Emergency- T0-.../E, .../Z V/EA/SVB-SW-T0 1 off plate FS908) into interlocked
handle and black Stop function T3-.../E, .../Z 065011 T.../V/SVB rear mounting main
locking ring T5(B)-.../E, .../Z V/EA/SVB-SW-T5 1 off switches
045064
Thumb-grips
Black KNB-T0 10 off
038909
Red, only for KNB-RT-T0 10 off Order additional yellow front
Emergency-Stop 043655 plate FS908GE-T0
switch, according
to IEC/EN 60204-1,
VDE 0113 Part 1

Black KNB-P3 10 off


041282
Red, only for KNB-RT-P3 10 off Order additional yellow front
Emergency-Stop 046028 plate FS908GE-P3
switch, according
to IEC/EN 60204-1,
VDE 0113 Part 1

Maintenance key for locked main switch


For interlocked KNK-T0 5 off Special devices for electricians,
main switches 000650 to allow them to switch
interlocked main switches On
For interlocked KNK-P3 5 off and Off,
main switches 000649 when the panel door is open for
maintenance purposes (to IEC/
EN 60204-1, Clause 5.1.1.1)

ATEX style
According to 94/9EG
Test Certificate BVS04E106X
Only available together with basic device
with metric knock-outs M20 T0-.../I1 +ATEX-I1 1 off
237513
T3-.../I2 +ATEX-I2 1 off
P1-.../I2 237514
with solid side walls T5B-.../I4 +ATEX-I4 1 off
P3-.../I4 237516
T5-.../I5 +ATEX-I5 1 off
P3-.../I5 237517
7/44 Ordering
Front plates
FS-T0(P3) Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Size Dimensions (W x H x D) Part no. Price Std. pack


Article no. see price list

mm

Standard front plates


Can be laser inscribed
T0, T3, P1 45 x 45 (for size 48 x 48) FS(*)-T0 10 off
231893
P3, T5, T5B 84 x 84 (for size 88 x 88) FS(*)-P3 10 off
231895
Emergency-Stop front plates

T0, T3, P1 45 x 45 (for size 48 x 48) FS908GE-T0 5 off
003198
P3, T5, T5B 84 x 84 (for size 88 x 88) FS908GE-P3 5 off
031475
Blank plates
Can be engraved
P3, T5, T5B 84 x 84 (for size 88 x 88) FS-ALU980-P3 10 off
266906
T0, T3, P1 45 x 45 (for size 48 x 48) FS-ALU980-T0 50 off
266905

Notes
Standard front plates
For standard contact sequence the normal front plate can be replaced if required with the front plate shown here (not with T6, T8 and TM). This is provided the switching
angle, number of positions and the position of the 0 position are the same.

Switching angle 30

23 34 234 345 2 34 3 45 2 34 2 34 345 234 345 2 3 4 345 234 345 2 34 345


1 2 1 2 1 5 2 6 1 5 1 5 2 6 1 5 2 6 1 5 2 6 1 5 2 6 1 5 2 6
0 1 0 1 0 1 0 6 0 6 1 7 0 6 1 7 0 6 1 7 0 6 1 7 0 6 1 7
7 8 7 8 7 8 7 8 11 7 12 8
8 9 9 8 10 9 10 9 8 1110 9 10 9 8 1110 9

318 309 317 308 316 307 315 314 305 313 304 312 303 311 302 310 301

Switching angle 45

0 STOP OFF HAND 0 STOP 1 1 0 0 0


1 2 1 ON AUTO 1 1 0 0 2 1 2 2 1 HAND AUTO
0 1 START START

416 402 415 142003 147472 141883 455 141879 4721 4722 4723 496 41409 429 1401
AUS OFF AUS HALT HALT STOP 1 1 0 0 0 0 OFF
AUTO HAND HAND AUTO LANG- SCHNELL LINKS RECHTS ZU- VOR. FORW. REV. 0 2 2 1 1 2 1 HAND AUTO HAND AUTO
SAM 2
RUCK 0 START

1411 1420 1475 1404 1403 141538 147767 461 4026 462 4117 1414000 1413905
0 0 0 0 0 0 0 1 1 STOP 0 2 3 2 3 2
1 2 2 1 LINKS RECHTS 0 1 AUTO HAND 1 2 1 3 2 4 1 3
AUS EIN AUF ZU TRIP CLOSE AUS EIN STOP START FORW. REV.
START 0 1 0 1 0 4
RAISE LOWER

4011 458 1426 14988 147474 1413903 1446 456 1423 14510 141537 1413890 418 404 420 406 422
3 0 0 0 0 0 0 STOP 0 2 3 2 3 0 2
2 4 1 1 3 1 Y Y 1 1 2 1 1 2 FORW. REV. START START 1 3 2 4 1 3 2 4 1 1 1 3
1 5 2 2 4 2 2 2 START START 2 1 0 4 1 5 0 4 1 5 2 2 0 4
START START START START
5 6 5 3 3 7 5
6 7 6 6

408 441 453 4017 459 1409 140660 14712 142074 424 410 426 412 449 428
3 L2-N S-O L2-L3 S-T L1-L2 L1-N 0 OFF 0 OFF 0 OFF OFF 0
2 4 L1-L2 L1-N R-S R-O R-S START
L1-N L3-N R-O T-O L1-L2 L3-L1 R-S T-R 0 L2-L3 0 L2-N L1-L2 L1-N L1-L2 L1-L2 R-S
1 5 0 0 0 0 L1-N L3-L1 L1-L2 L3-N L2-L3 L2-N L2-L3 L2-N S-T S-O L2-L3 L2-L3 S-T S-T L3-L1 L1-L2 L3-N L1-N 1
8 6 L3-L1 L3-N L3-L1 L3-N T-R T-O L3-L1 L3-L1 T-R T-R
7 L2-L3 L2-N

414 1410757 14196 1410755 14195 1410756 1410758 1410759 147479 14944 1410763 140055 194321 194323 142010

Switching angle 60

0 1 HAND 1 SLOW Y START 0 0 0 NOT- 0 HALT HALT AUS AUS OFF OFF
1 2 AUTO 0 2 STOP FAST 0 STOP RUN 1 2 2 1 NETZ STROM LINKS RECHTS 2 1
AUF AB AUF AB HAND AUTO AUTO HAND HAND AUTO

611 601 1601 644 16052 635 16616 684 621 161629 161570 161359 161358 1610 1614 1673 1617
OFF OFF STOP STOP 2 L2-N L2-L3 1 2 0
AUTO MAN FORW. REV.
2 3 1 2 LOW MED. 2 3 Y
FORW. REV. SLOW FAST 1 3 L1-N L3-N L1-L2 L3-L1
0 1 0 3 OFF HIGH 1 4

1627 1628 1662 1665 655 164855 164854 614 604 616 160772 606 6034
START 0 0 0 STOP 0 STOP 1 2 1 2 2 3 0 0 L2-L3 S-T
1 2 3 3 1 1 1 SLOW SLOW Y Y START START 2 1 Y L1-L2 L3-L1 R-S T-R
0 0 3 0 3 1 4
1 4 4 2 2 2 FAST FAST RUN RUN 1 2 Y L3-N L1-N T-O R-O
4 5 4 6 5 0 0 L2-N S-O

164222 667 645 629 161002 638 161683 618 620 610 640 6010 164721 661

Switching angle 90

ON 1 2 EIN 1 0 0 1 AUS EIN STOP START HAND AUTO AUF ZU AUF AB UP DOWN SLOW FAST
1 2
0 1 AUS STOP 1
OFF HEIZUNG-
NOTSCHALTER

908 9508 902 190719 193935 907 945 1992 190334 943 19334 190550 19143 193975 190431
1 0 OFF 2 1 ON OFF 1 1 0 1 0 1 2 0 0 OFF AUTO

0 2 1 2 1 2 1 3 0 0 OFF OFF ON ON 2 2 0 0 1 2 0 1+2 3 1 0 2 1 3 L3 L1 T R L3 L1 ZU AUF

1 ON OFF 1 2 0 2 2 3 4 L2 S L2 AUS

910 953 192190 904 926 1957 192191 923 928 9441 193840 911 912 906 9440 935 19589 1922
Ordering 7/45
Add-on front plates
http://catalog.moeller.net Moeller HPL0211-2007/2008 ZFS

Rotary switches, switch-disconnectors


Explanation Language For use with Part no. Price Std. pack
Article no. see price list

Add-on front plates, clip-on


for padlocking feature consists of label mount and insert label
Inscribed with standard text "main switch only open in 0 position" in various languages
Blank, can be engraved

Blank, can be engraved None Rotary switches T0, T3, P1 ZFS60-T0 25 off
019924
Blank, can be engraved None Switch-disconnectors T5(B), P3 ZFS60-P3
022297
Engraved with standard text German/English Rotary switches T0, T3, P1 ZFS61/62-T0
030170
Engraved with standard text Spanish Switch-disconnectors T5(B), P3 ZFS77-P3
047422
Engraved with standard text French Switch-disconnectors T5(B), P3 ZFS63-P3
047423
Engraved with standard text French Rotary switches T0, T3, P1 ZFS63-T0
047424
Engraved with standard text German/English Switch-disconnectors T5(B), P3 ZFS61/62-P3
065739
Engraved with standard text Italian Rotary switches T0, T3, P1 ZFS68-T0
065751
Engraved with standard text Spanish Rotary switches T0, T3, P1 ZFS77-T0
065752
Engraved with standard text Hungarian Switch-disconnectors T5(B), P3 ZFS80-P3
205565
Engraved with standard text Portuguese Rotary switches T0, T3, P1 ZFS72-T0
205541
Engraved with standard text Swedish Rotary switches T0, T3, P1 ZFS75-T0
205544
Engraved with standard text Hungarian Rotary switches T0, T3, P1 ZFS80-T0
205548
Enter country reference when ordering:
D = German Switch-disconnector P5-.../EA/SVB ZFS(*)-P5 1 off
GB = English Switch-disconnector P5-.../V/SVB 105225
F = French
I = Italian
E = Spanish
Label mounts, black, plug-in type

Rotary switches T0, T3, P1 ZFSX-T0 25 off


024670
Switch-disconnectors T5(B), P3 ZFSX-P3 25 off
027043
Insert plates

Rotary switches T0, T3, P1 BS45X14-T0 25 off


029416
Switch-disconnectors T5(B), P3 BS84X24-P3 25 off
031789
7/46 Ordering Ordering 7/47
Key operation, locking interlock Key operation, locking interlock
S, SVA, SVC Moeller HPL0211-2007/2008 http://catalog.moeller.net http://catalog.moeller.net Moeller HPL0211-2007/2008 S, SVA, SVC
Rotary switches, switch-disconnectors

Rotary switches, switch-disconnectors


For use with Key withdrawal/locking Part no. Price Std. pack Notes
option Article no. see price list

S-T0 key operated lock mechanism, Front IP53


Includes two keys
KMS 1 lock mechanism Individual lock mechanism, not T0-.../E, .../I1, .../Z up to max. 6 contact units Key withdrawal positions S-T0 1 off The key replaces the thumb-grip, cannot be switched without key. The switch position indication in on the
suitable for master key systems T3-.../E, .../Z up to max. 5 contact units can be programmed by the 086709 lock. Normally the key is withdrawable in every position.
T3-.../I2 up to max. 4 contact units user With the ordering of a rotary switch with front plate FS908 together with key operation the key is only
KMS 2-10 lock mechanisms, KMS 201-400 lock mechanisms: P1-.../E, .../I2, .../Z S-SOND-KMS(*)-T0 1 off withdrawable in the 0 position.
Individual lock mechanisms, not suitable for master key 231957 The key removability can be changed (also retro) with the locking cam "VR-T0".
systems With retrofitting of key operation the existing front plate of the rotary switch must be used.
Key a page 7/50

Lock KMS1: Switch with FS908 are possible as main switch for T0-.../E, .../I1, .../Z up to max. 6 contact units Key withdrawal positions S(*)-T0 1 off
T0-1-... to T0-4-.../I1, .../E; T3-1-... to T3-4-.../I2; T3-1-... to T3- T3-.../E, .../Z up to max. 5 contact units are programmed ex-works 231959
6-.../E; P1-.../I2, .../E T3-.../I2 up to max. 4 contact units as ordered
SA(...) = Master key system (with master key) supplied with a P1-.../E, .../I2, .../Z S(*)-SOND-SA(*)-T0 1 off
security certificate. Order must include a lock plan showing 231965
the full configuration of the envisaged lock system. For
subsequent part orders, simply state the item number within
the lock plan, e.g. (A6294-1/2).

SVA-T3 cylinder lock, Front IP65


Includes two keys
KMS 1 lock mechanism Individual lock mechanism, not T0-.../E, .../I1, .../Z Key withdrawal positions SVA-T3 1 off
suitable for master key systems T3-.../E, .../I2, .../Z can be programmed by the 050974 Switched with thumb-grip. The front plate of the switch is to be used for
P1-.../E, .../I2, .../Z user Locked by turning the key. The key is removable. Normally all retroffitting. With the letter S use for panic
KMS 2-10 lock mechanisms, KMS 201-400 lock mechanisms: SVA-SOND-KMS(*)-T3 1 off positions can be locked. lock FS908GE.
Individual lock mechanisms, not suitable for master key 231967 Individual positions or ranges are lockable (also retro with Ordering example: P1-25/I2-RT+SVA(S)-T3
systems VR-T3). In positions that are not lockable the key cannot be
removed. With lockable ranges only inside the range can be
E
D F
switched without the key. C G
The positions or ranges to be locked must be entered as
follows in the form. B 330
0
30 H
Example 1: SVA(A)-T3 = only position A withdrawable 60
300
Example 2: SVA(A, E)-T3 = only position A and E 315 45
withdrawable A 270 90 J
KMS1 lock mechanism: Switches with FS908 are suitable as T0-.../E, .../I1, .../Z Lockable positions can be SVA(*)-T3 1 off Example 3: SVA(A-J)-T3 = range A to J withdrawable 225 135
main switches: T0-1-... to T0-4-.../I1, .../E; T3-1-... to T3-5-.../ T3-.../E, .../I2, .../Z programmed by the user 907745 Example 4 SVA(S)-T3 = main switch for use as Emergency- 240 120
I2; T3-1-... to T3-6-.../E; P1-.../I2, .../E P1-.../E, .../I2, .../Z Stop according to IEC/EN 60204-1, VDE 0113 Part 1, with red 210 150
SA(...) = Master key system (with master key) supplied with a SVA(*)-SOND-SA(*)-T3 1 off thumb-grip and yellow front plate "Panic lock version" R 180 K
security certificate. Order must include a lock plan showing 231971 lockable in positions A and E, from E it can still be switched Q L
the full configuration of the envisaged lock system. For to A but not from A to E. P M
subsequent part orders, simply state the item number within N
the lock plan, e.g. (A6294-1/2). Ordering example for a master key system:
SVA(A-G)-SOND-SA(A6294-1/2)-T3
Key a page 7/50

SVC-T3 padlocking feature, Front IP65


In the depressed position, the locking slide is lockable with up to 3 padlocks
All positions are lockable T0-.../E, .../I1, .../Z Lockable positions can be SVC-T3 1 off
T3-.../E, .../I2, .../Z programmed by the user 050975 Switched with thumb-grip. Interlocked by pushing a button that Ordering example:
P1-.../E, .../I2, .../Z is lockable with 1-3 padlocks. Normally all positions can be P1-25/I2-RT+SVC(S)-T3
Specified positions or ranges are lockable T0-1-... to T0-4-.../I1, .../E Lockable positions are SVC(*)-T3 1 off lokked. By entering SCV(...)-T3 only the entered position is
T3-1-... to T3-5-.../I2 programmed ex- works as 907748 lockable. Locked ranges can only be switched within the range
E
T3-1-... to T3-6-.../E ordered
D F
without removing the padlocks. C G
P1-.../I2, .../E The positions or ranges to be locked must be entered in the
P1-.../I2, .../E form. B 330
0
30 H
Form a Notes to SVA(...)-T3 60
300
The front plate of the switch is to be used for retroffitting. With 315 45
the letter S use for panic lock FS908GE. A 270 90 J
225 135
240 120
210 150
R 180 K
Q L
P M
N
7/48 Ordering
Neutral poles, auxiliary switches, central mounting accessories
N-P1, N-P3, N-P5 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

For use with Part no. Price Std. pack


Article no. see price list

Neutral poles
Early-make, late-break
For side mounting, left or right P1-.../E, .../EA, .../EZ N-P1E 5 off
000651
With P1-.../I2: optional N-P1Z or HI11-P1/P3Z can only P1-.../Z, .../V, .../I2, .../IVS N-P1Z
be fitted to left 000652
P3-.../E, .../EA... N-P3E
062432
P3-.../Z, .../V, .../IVS N-P3Z
P3-63/E,.../Z, /I4 064805
P3-100/E, .../Z, .../I5
Neutral terminal
For side mounting P5-250(315)/Z(V) N-P5-250/315Z 1 off
280972
Protective conductor terminal
For side mounting P5-125(160)/E(EA) PE-P5-125/160E 1 off
280973
P5-250(315)/Z(V) PE-P5-250/315Z
280976
Auxiliary contacts
Late making N/O and early breaking N/C contacts. The N/O is always connected as a load-shedding contact.

For side mounting, left and/or right P1-.../E, .../EA..., .../EZ HI11-P1/P3E 5 off
P3-.../E, .../EA 061813
With P1-.../I2: HI11-P1/P3Z or N-P1Z can be fitted to left P1-.../Z, .../V, .../I2, .../IVS HI11-P1/P3Z
only P3-63/Z, .../V, .../I4, .../IVS 062031
P3-100/Z, .../V, .../I5, .../IVS
Centre mounting accessories
For single-hole fitting
Mounting diameter 22.3 mm
For rotary switches with existing front plate T0-.../E EZ-T0 1 off
T3-.../E 081622
Mounting diameter 22.3 mm and 30.5 mm T0-.../E EZ-P1 1 off
T3-.../E 091455
P1-.../E
Service distribution board mounting accessories
Includes push-fit shaft
For retrofitting T0-.../XZ basic switches as T0-.../IVS into T0-.../XZ IVS-T0 1 off
service distribution boards 091114
Ordering 7/49
Coupling drive, interlock parts, shaft extension
http://catalog.moeller.net Moeller HPL0211-2007/2008 DE-T0(P3), ZAV-T0(P3)

Rotary switches, switch-disconnectors


For use with Type suffix/Type Price Std. pack Notes
Article no., When ordered see price
with basic unit/ ordered list
separately

Coupling drive
Includes push-fit shaft
For retrofitting T0(T3)-.../XZ DE-T0 1 off
basic switches in the rear 093487
mounting form Spare parts
for T0(T3)/(P1)-.../Z

For conversion of T5 (B)-.../E DE-P3 3 off


flush mounting switch into a 093972
rear mounting switch Spare
parts for T5(B)/(P3)-.../Z

Interlock sections
With PE and N conductor connection
Fits on the reverse of flush mounting switches, with interlocking function for rear
mounting switches.
T0-.../E, ...EZ, ...Z UV-T0 1 off Fits on the reverse of
T3-.../E, ...EZ, ...Z 019925 flush mounting
P1-.../E, ...EZ, ...Z switches
T5(B)-.../E, ...Z UV-P3 With interlocking
P3-.../E, ...Z 048289 function for rear
mounting switches

Interlock extensions
Up to four off, 25 mm each, can be plugged onto interlock section
(An equal number of shaft extensions is required for this purpose)
Use ZVV-T0 only with T0/T3- UV-T0 ZVV-T0 10 off Use ZVV-T0 only with
.../Z and P1-.../Z 022298 construction type T0/
T3-.../Z and P1-.../Z

Use ZVV-P3 only with T5(B)- UV-P3 ZVV-P3 Use ZVV-P3 only with
.../Z and P3-.../Z 024671 construction type
T5(B)-.../Z and P3-.../Z

Shaft extensions
Up to four off, 25 mm each, can be plugged onto switch shaft
T0-.../Z, T0-.../V ZAV-T0 10 off
T3-.../Z, T3-.../V 027044
P1-.../Z, P1-.../V
T5(B)-.../Z ZAV-P3
P3-.../Z 029417
Shaft
Aluminium, length: 480 mm P5-.../V... ZAV-P5 1 off
P5-.../Z 280979
Interlock extensions und shaft extensions, complete
Only available in conjunction with a basic unit
Extension up to 25 mm when ordered +ZAV(X1)+ZVV(X1)-T0/P3 1 off
with basic unit 254546

Control circuit terminal


P5-250/315 ST-P5-250/315 1 off Terminal capacity
280978 solid or stranded:
4 mm2
Flexible with ferrules
to DIN 46228:
4 mm2
7/50 Ordering
Shrouds, Keys
H Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

For use with Part no. Price Std. pack Notes


Article no. see price list

Shrouds
For flush-mounting switches with T0-.../E H3-T0 1 off Cable entries
up to 4 contact units T3-.../E 093828 Quantity:
2 x o 20 mm
+ 2 x o 15 mm
Cross-section:
5 x 6 mm2
5 x 2.5 mm2
Cover for protection of terminals T5(B)-.../E, .../Z H1-T5 Can be used for input and/or
For up to 2 contact units 045062 output wiring

Extension of H1-T5 cover To H1-T5 HZ-T5 10 off 1 x HZ-T5 required per


protect 3 to 8 contact units 045063 contact unit

To cover terminals on 3-pole P1-.../E, .../EZ, H-P1 5 off Can be used for input and/or
switch-disconnectors .../Z, .../EA, .../V 017253 output wiring

To cover terminals on 4-pole P1-...N, ...HI11, H-P14 Can be used for input and/or
switch-disconnectors ...N...HI11 019626 output wiring

To cover terminals on 3-pole open P3-.../E, .../Z, .../ H-P3 The shroud is designed for
switch-disconnectors with N EA, .../V 021999 fitting onto both sides of the
neutral conductor and/or HI11 P3-...N, ...HI11, switch-disconnector. Parts
auxiliary contact modules fitted ...N...HI11 which are not required can
be broken off.

Set of three, to protect the P5 H-P5-125/160-3P 3 off


terminals 280967

Cover assembly to protect the 6 T8-3-8342/... H-T8


terminals 200184

Keys
For KMS 1 individual lock ES-KMS1-T0 10 off
mechanism 231972
For KMS 2 - 10 individual lock ES-KMS(*)-T0
mechanism or KMS 201 - 400 231973
Individual key, corrosion-proof, for HS-SA(*)-T0 Master keys must always be
master key systems and recorded 256151 ordered separately.
individual lock mechanisms: state Please send or submit the
lock plan no. and lock security certificate with
repeat orders.
Ordering example:HS-
SA(A6294-1/2)-T0

Locking cams (2 cams per set)

For user to select indexing position S-T0 for all VR-T0 1 off
in which key can be withdrawn switching 089082
angles

Mounting plate screen


To connect the screeniing CI-K2 MBS-I2 2 off
290191
Ordering 7/51
Insulated enclosures, accessories
http://catalog.moeller.net Moeller HPL0211-2007/2008

Rotary switches, switch-disconnectors


For use with Part no. Price Std. pack Notes
Article no. see price list

IP65 insulated enclosures

Enclosures designed for metric cable glands to EN 50262


1 2 contact units With push- T0-.../XZ CI-K1-T0-2 1 off Cable sizes which may be pushed
through cable 207435 through the diaphragm
3 - 4 contact units entry T0-.../XZ CI-K1-T0-4 1 off Main-/control current
diaphragm. 207436 12 mm/
16 mm/8 mm
1 2 contact units T3-.../XZ CI-K2-T3-2 1 off 1 contact unit = 2 contacts
207437
5 contact units T3-.../Z CI-K2-T3-5 1 off
207438
3 - 4 contact units T3-.../XZ CI-K2-T3-4 1 off
225325
1 2 contact units With metric T0-.../XZ CI-K1H-T0-2 1 off
knock-outs 105854
3 - 4 contact units T0-.../XZ CI-K1H-T0-4 1 off
105855
1 2 contact units T3-.../XZ CI-K2H-T3-2 1 off
269462
3 - 4 contact units T3-.../XZ CI-K2H-T3-4 1 off
105859
5 contact units T3-.../XZ CI-K2H-T3-5 1 off
105860
1 2 contact units T5B-.../E CI-K4-T5B-2 1 off Converts T5-.../Z into T5-.../I5 and
207439 T5B-.../E into T5B.../I4:
3 - 4 contact units T5B-.../Z CI-K4-T5B-4 1 off Order AW-T5-... extension terminals
207440 in addition
1 contact unit = 2 contacts
1 2 contact units T5-.../Z CI-K5-T5-2 1 off
207441
3 - 4 contact units T5-.../Z CI-K5-T5-4 1 off
207442
only available together T0-.../I1 +I1H 1 off
with basic device 105870

only available together T3-.../I2 +I2H 1 off


with basic device P1-.../I2 105871

Neutral terminals
For connection of 5th conductor
CI-K2-PKZ0-... K-CI-K1/2 20 off
207451
T5B-.../I4, K-CI-K4 20 off
Cl-K4-T5B-... 206916
P3-.../I4
CI-K4
T5-/I5, K50/1 10 off
CI-K5-T5- 098573
P3-/I5
CI-K, 100 A
T5-.../I5, K-CI-K5 20 off
CI-K5-T5-... 218488
P3-.../I5
CI-K5
Set of external fixing brackets
T5B-.../I4, AB-CI-K4/5 1 off For fixing CI-K4 and CI-K5 directly
T5-.../I5, 206914 to the wall.
P3-63/I4, One set comprises 4 brackets.
P3-100/I5,

Set of extension terminals


For retrofitting
For cable connection in the enclosure
For the lowest contact unit T5B-.../I4 AW-T5-1/2 10 off Included with T5B-.../I4 and T5-.../I5
T5-.../I5 032601 as standard.
For the second contact unit from the T5-.../I5 AW-T5-3/4 1 off Included with T5B-.../I4 and T5-.../I5
bottom 032602 as standard.
7/52 System overview
Mini rotary switches
TM Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

ON-OFF switches TM
1

2
10

9
9

8
7

5
8

6
8 8
6 4
6 4 3

8 4

Control switch TM

2
10

11

9 11

O
HA
ND

5 AU
TO

0
6
6 3
1

4
4
4
System overview 7/53
Mini rotary switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM

Rotary switches, switch-disconnectors


Flush mounting (.../E) 1 Centre mounting (.../EZ) 2 Standard switch for centre mounting 5, 6
Front IP 65
Mounting from rear in walls, plates or Front IP 65 Black thumb-grip
doors Mount in fixing hole 16.2 o or 22.3 o a page 7/54
Terminals: according to IEC/EN 60947-5-1 after
removing provided the adapter
Crosshead screwdriver Pozidrive Control circuit isolator 7, 8
Fingerproof a page 7/54
Red rotary handle and yellow locking collar
a page 7/54
Key operation for centre mounting 3, 4 Black rotary handle and black locking collar
Flush mounting control circuit isola- 1 2 keys are supplied
tor (.../E/SVB) Lockable in the 0 position
Key withdrawable 90 a page 7/54
Front IP 65
To IEC/EN 60947-5, VDE 0660 Key withdrawable 60 with RONIS lock
0 position lockable with 2 padlocks 4 mm cylinder. Standard switch for flush mounting 9, 10
o or 1 padlock 6 mm o
a page 7/59 Black thumb-grip
Can be used with up to 250 V AC per a page 7/55
contact
Maximum 6 contacts permissible Standard switch for distribution 11
a page 7/54 board mounting IVS
Mounting in service distribution board
Mounting width: 2 TE (45 mm mounting
depth)
up to 2 contact units

Product features

Contact chamber Switch postion


Rated uninterrupted current 10 A Safety due to latching
Gold plated contacts for safe switching of Switching angle 30, 45, 60, 90
small voltages and currents also in agressive Spring action with automatic return with max.
atmospheres 6 contacts, switching angle f 60
-Positively opening contacts Complete rotation
1 2 contacts per switching chamber (BE), up With a total switching angle of 360 complete
to 16 contacts per switch rotation is possible in both directions
For switching differing potentials
Control circuit reliability
7/54 Ordering
Control circuit isolators, On-Off switches
TM Moeller HPL0211-2007/2008 http://catalog.moeller.net

Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price list

Control circuit isolators, 90


Mini rotary switches

With padlocking facility, lockable in the Off position


Up to 250 V AC per contact
1 Flush mounting Front IP65 TM-1-8290/E/SVB-SW 1 off
0 1

215351
1
2

Flush mounting Front IP65 TM-1-8290/E/SVB


045477
2 Flush mounting Front IP65 TM-1-8291/E/SVB-SW
0 1

215352
1
2
3
4

Flush mounting Front IP65 TM-1-8291/E/SVB


045478
3 Flush mounting Front IP65 TM-2-8292/E/SVB
0 1

045484
1
2
3
4
5
6

Flush mounting Front IP65 TM-2-8292/E/SVB-SW


210955
3+N Flush mounting Front IP65 TM-2-8293/E/SVB
0 1

045485
1
2
3
4
5
6
7
8

6 Flush mounting Front IP65 TM-3-8326/E/SVB


0 1

045498
1
2
3
4
5
6
7
8
9
10
11
12

On-Off switches, 90
1 1 Centre Front IP65 TM-1-8290/EZ 1 off
0 1

0 mounting 000693
1
2

F 056

Flush mounting Front IP65 TM-1-8290/E


070131
2 Centre Front IP65 TM-1-8291/EZ
0 1

mounting 015073
1
2
3
4

Flush mounting Front IP65 TM-1-8291/E


072504
3 Flush mounting Front IP65 TM-2-8292/E
0 1

074877
1
2
3
4
5
6

Centre Front IP65 TM-2-8292/EZ


mounting 015096

3+N Flush mounting Front IP65 TM-2-8293/E


0 1

077250
1
2
3
4
5
6
7
8

Centre Front IP65 TM-2-8293/EZ


mounting 045486

6 Flush mounting Front IP65 TM-3-8326/E


0 1

079623
1
2
3
4
5
6
7
8
9
10
11
12
Ordering 7/55
Changeover switch, hand/automatic switch
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM
Contact sequence Front No. of Design Protection Part no. Price Std.
plate no. poles type Article no. see price pack
list

Changeover switches
1 2 Without 0 1 Centre mounting Front IP65 TM-1-8220/EZ 1 off
1 2

position, 60 000692

Mini rotary switches


1 Flush mounting Front IP65 TM-1-8220/E
1
2
3
4

F 072
081996
2 Centre mounting Front IP65 TM-2-8221/EZ
1 2

015197
2 Flush mounting Front IP65 TM-2-8221/E
1
2
3
4
5
6
7
8

084369
3 Centre mounting Front IP65 TM-3-8222/EZ
1 2

045493
3 Flush mounting Front IP65 TM-3-8222/E
1
2
3
4
5
6
7
8
9
10
11
12

086742
4 Centre mounting Front IP65 TM-4-8223/EZ
1 2

046119
4 Flush mounting Front IP65 TM-4-8223/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

089115
5 Centre mounting Front IP65 TM-5-8369/EZ
1 2

046126
5 Flush mounting Front IP65 TM-5-8369/E
091488
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

6 Flush mounting Front IP65 TM-6-8370/E


1 2

093861
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

0 With 0 1 Centre mounting Front IP65 TM-1-8210/EZ


1 0 2

1 2
position, 60 015137
1 Flush mounting Front IP65 TM-1-8210/E
F 071
096234
1
2
3
4

2 Centre mounting Front IP65 TM-2-8211/EZ


1 0 2

015166
2 Flush mounting Front IP65 TM-2-8211/E
098607
1
2
3
4
5
6
7
8

0 3 Centre mounting Front IP65 TM-3-8212/EZ


1 0 2

2 1
045491
F 249 3 Flush mounting Front IP65 TM-3-8212/E
010807
1
2
3
4
5
6
7
8
9
10
11
12

3 Flush mounting Front IP65 TM-3-8299/E


020299
4 Centre mounting Front IP65 TM-4-8213/EZ
1 0 2

045847
4 Flush mounting Front IP65 TM-4-8213/E
013180
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

0 With 0 2 Flush mounting Front IP65 TM-2-8219/E


1 0 2

1 2
position, 90 017926
F 057
1
2
3
4
5
6
7
8

With spring- 1 Flush mounting Front IP65 TM-1-8214/E


2

1 0 2
return from 032164
0
1

both
F 025 directions,
1
2
3
4

30 2 Flush mounting Front IP65 TM-2-8215/E


2

034537
0
1
1
2
3
4
5
6
7
8

Hand-Auto switches, 60
AUTO HAND AUTOM 1 Centre mounting Front IP65 TM-1- 1 off
HAND
8220F288/EZ
016925
F 288
1
2
3
4

AUTO
HAND
0
AUTO
1 Flush mounting Front IP65 TM-1-15431/E
0
HAND
025045
F 085 1 Centre mounting Front IP65 TM-1-15431/EZ
000691
1
2
3
4

1 Service distribution Front IP30 TM-1-15431/IVS


board mounting 225342

AUTO 2 Centre mounting Front IP65 TM-2-15432/EZ


0
HAND
016878
2 Flush mounting Front IP65 TM-2-15432/E
027418
1
2
3
4
5
6
7
8

AUTO 3 Centre mounting Front IP65 TM-3-15433/EZ


0
HAND
045490
3 Flush mounting Front IP65 TM-3-15433/E
029791
1
2
3
4
5
6
7
8
9
10
11
12
7/56 Ordering
Control switch, step switch
TM Moeller HPL0211-2007/2008 http://catalog.moeller.net

Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price
list

Step switches
Mini rotary switches

Without 0 (Off) position


3 steps, 60
1 Flush mounting Front IP65 TM-2-8230/E 1 off
1 2 3

2 3
1 039283
1 Centre mounting Front IP65 TM-2-8230/EZ
F 076 000701
1
2
3
4
5
6

3 Flush mounting Front IP65 TM-5-8270/E


1 2 3

041656
3 Centre mounting Front IP65 TM-5-8270/EZ
046124
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

4 steps, 60
1 Flush mounting Front IP65 TM-2-8231/E
1 2 3 4

2 3
1 4 044029
1 Centre mounting Front IP65 TM-2-8231/EZ
F 077 000700
1
2
3
4
5
6
7
8

3 Flush mounting Front IP65 TM-6-8271/E


1 2 3 4

046402
3 Centre mounting Front IP65 TM-6-8271/EZ
046128
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

5 steps, 60
1 Flush mounting Front IP65 TM-3-8232/E
1 2 3 4 5

2 3
1 4 039298
5
1 Centre mounting Front IP65 TM-3-8232/EZ
F 078 015592
1
2
3
4
5
6
7
8
9-
10

2 Flush mounting Front IP65 TM-5-8252/E


041671
2 Centre mounting Front IP65 TM-5-8252/EZ
046123
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

6 steps 60, no full rotation


1 Flush mounting Front IP65 TM-3-8233/E
1 2 3 4 5 6

2 3
1 4 053521
6 5
1 Centre mounting Front IP65 TM-3-8233/EZ
F 079 015630
1
2
3
4
5
6
7
8
9
10
11
12

2 Flush mounting Front IP65 TM-6-8253/E


055894
2 Centre mounting Front IP65 TM-6-8253/EZ
046127
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

10 steps, 30
345
1 Flush mounting Front IP65 TM-5-8237/E
2
1
8
6
7 069150
10 9
1 Centre mounting Front IP65 TM-5-8237/EZ
F 011 015661
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Ordering 7/57
Control switch, step switch
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM

Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price
list

Step switches

Mini rotary switches


With additional 0 (Off) position
2 steps, 60
1 Flush mounting Front IP65 TM-1-8240/E 1 off
0 1 2

1 2
0 058267
1 Centre mounting Front IP65 TM-1-8240/EZ
F 075 015226
1
2
3
4

2 Flush mounting Front IP65 TM-2-8260/E


0 1 2

060640
2 Centre mounting Front IP65 TM-2-8260/EZ
045483
1
2
3
4
5
6
7
8

3 Flush mounting Front IP65 TM-3-8280/E


0 1 2

063013
3 Centre mounting Front IP65 TM-3-8280/EZ
045496
1
2
3
4
5
6
7
8
9
10
11
12

3 steps, 45
1 Flush mounting Front IP65 TM-2-8241/E 1 off
0 1 2 3

1 2 3
0 065386
F 109 1 Centre mounting Front IP65 TM-2-8241/EZ
015256
1
2
3
4
5
6

2 Flush mounting Front IP65 TM-3-8261/E


0 1 2 3

067759
2 Centre mounting Front IP65 TM-3-8261/EZ
000698
1
2
3
4
5
6
7
8
9
10
11
12

3 Flush mounting Front IP65 TM-5-8281/E


0 1 2 3

070132
3 Centre mounting Front IP65 TM-5-8281/EZ
046125
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

4 steps, 30
234 1 Flush mounting Front IP65 TM-2-8242/E 1 off
0 1 2 3 4

1
0 072505
F 002 1 Centre mounting Front IP65 TM-2-8242/EZ
015506
1
2
3
4
5
6
7
8

2 Flush mounting Front IP65 TM-4-8262/E


0 1 2 3 4

074878
2 Centre mounting Front IP65 TM-4-8262/EZ
046120
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

3 Flush mounting Front IP65 TM-6-8282/E


0 1 2 3 4

077251
3 Centre mounting Front IP65 TM-6-8282/EZ
046129
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

5 steps, 30
1 Flush mounting Front IP65 TM-3-8243/E 1 off
0 1 2 3 4 5

2 34
1 5
0 079624
1 Centre mounting Front IP65 TM-3-8243/EZ
F 003 015537
1
2
3
4
5
6
7
8
9
10

6 steps, 30
1 Flush mounting Front IP65 TM-3-8244/E 1 off
0 1 2 3 4 5 6

2 34
1 5
0 6 081997
1 Centre mounting Front IP65 TM-3-8244/EZ
F 004 045495
1
2
3
4
5
6
7
8
9
10
11
12

9 steps, 30
1
2 3 4
5
1 Flush mounting Front IP65 TM-5-8247/E 1 off
0
7
6 009741
98

F 007
1 Centre mounting Front IP65 TM-5-8247/EZ
015565
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
7/58 Ordering
Control switches: group switches (OFF) spring-return switch, reversing switches, coding switches
TM Moeller HPL0211-2007/2008 http://catalog.moeller.net

Contact sequence Front plate Design Protection type Part no. Price Std. pack
no. Article no. see price list

Group switches
Mini rotary switches

2 groups, 60
2
1 2
Flush mounting Front IP65 TM-1-8310/E 1 off
1
0
0 084370
Centre mounting Front IP65 TM-1-8310/EZ
F 075 045479
1
2
3
4

3 groups, 30
2 3 Centre mounting Front IP65 TM-2-8311/EZ
3

1
0 045487
2
1

F 001
0
1
2
3
4
5
6

ON (OFF) switch
On switch 30
START START Centre mounting Front IP65 TM-1-8175/EZ 1 off
I
015690
1
2

F 023
ON-OFF switch 90/30 with spring-return from Start to 1

START 1 START Flush mounting Front IP65 TM-1-8178/E


1
0
0 098608
F 119 Centre mounting Front IP65 TM-1-8178/EZ
016786
1
2
3
4

Reversing switches
60 Degree
1
0
2
Flush mounting Front IP65 TM-3-8401/E 1 off
2

015554
0

F 071
1
1
2
3
4
5
6
7
8
9
10

Coding switches
BCD code 0-9, 30
1
2 3 4
5
Flush mounting Front IP65 TM-2-8550/E 1 off
0
7
6 020300
98

F 007
Centre mounting Front IP65 TM-2-8550/EZ
000699
2
3
4
5
6
7
8

BCD code 0-9 + complement, 30


1
2 3 4
5
Flush mounting Front IP65 TM-4-8552/E
0
7
6 025046
98

F 007
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ordering 7/59
Locks, front plates
http://catalog.moeller.net Moeller HPL0211-2007/2008 EZ/S-
Protec- Key withdrawable Part no. Price Std. pack Notes
tion type with suffix see price
Article no. list

Key operation Key operated lock mechanism including two keys.


The key can be withdrawn only in specified positions, see diagrams below.
Includes two keys However, the KABA lock mechanism for 90 can also be used for other

Mini rotary switches


For service distribution board mounting (IVS) switching angles provided the positions for key withdrawal correspond with
when ordered with basic unit those specified for the Type of switch.
Example: +EZ/S-B can be used on a step switch having a switching angle of
KABA lock IP65 0 +EZ/S-A 1 off 30, provided the key is to be withdrawn only in the Off position at 270.
90 045458
IP65 270 + 0 +EZ/S-F Options for key withdrawal
045463
IP65 270 +EZ/S-B
045459
A B C D E F G
RONIS lock IP55 270 + 330 + 30 + +EZ/S-J
60 90 + 150 + 210 045466
IP55 270 + 90 +EZ/S-D H J M N P Q R
045461
IP55 270 + 330 + 90 + +EZ/S-N
150 045468
IP55 300 + 0 + 60 + +EZ/S-H Postion marking for the example
120 + 180 + 240 045465
0
330 30
300 315 45 60
270 90
240 225 135 120
210 150
180

Size Dimensions (W x Part no. Std. pack Notes


H x D) Article no.
mm
Standard front plates
TM.../EZ 29 x 29 (for frame TM/EZ-FRONTSCHILD-NR(*) 1 off Standard front plates
size 30 x 30) 239022 For standard contact sequence the normal front plate can be replaced if
TM.../E 29 x 29 (for frame TM/E-FRONTSCHILD-NR(*) 1 off required with the front plate shown here. This is provided the switching
size 30 x 30) 239021 angle, number of positions and the position of the 0 position are the same.

Blank plates Switching angle 30


Can be engraved
TM 29 x 29 (for frame FS980-TM-E 10 off START STOP START 1 0 2 MAN
OFF
AUTO
1
2 AUTO 0 HAND AUTO 0 MAN AUTO
OFF
HAND

0
size 30 x 30) 071438
TM 29 x 29 (for FS980-TM-EZ 50 off F023 F024 F025 F039 F053 F258 F259 F708
frame size 30 x 073811 23 234 234 234 234 234 234 345
1 1 1 5 1 5 1 5 1 5 1 5 2 6
30) 0 0 0 0 6 0
7
6 0
7
6 0
7
6 1
8
7
8 98 10 9
F001 F002 F003 F004 F005 F006 F007 F011

Switching angle 45

1 0 2 2 2 3 0 OFF
0 2 1 2 1 3 1 3 1 3 2 4 1 1 1 1
0 OFF 1 2 2 2 2

F215 F216 F738 F109 F115 F330 F105 F113


2 3 0 3 0 0 3 2
1 3 2 4 1 1 2 4 L1-L2 L1-N L1-L2 L1-L2 2 4 1 3
0 4 1 5 2 2 1 5 L2-L3 L2-N L2-L3 L2-L3 1 5 0 4
3 3 6 L3-L1 L3-N L3-L1 L3-L1 8 6 7 5
7 7 6
F293 F741 F106 F110 F785 F788 F111 F322

Switching angle 60

1 2 AUTO MAN AUTO HAND 0 1 1 2 2 3 0


1 2 0 2 HAND AUTO
0 1

F072 F234 F288 F071 F073 F075 F076 F085


0 0 OFF 2 3 1 2 2 3 2 3 0
2 1 MAN AUTO AUTO HAND 1 2
1 4 0 3 1 4 1 4 START START
5 6 5

F249 F373 F732 F077 F102 F078 F079 F121

Switching angle 90

1 ON EIN 0 OFF 2
0 1 1 2
0 OFF AUS 1 2 MAN AUTO 1 3

F056 F063 F068 F700 F743 F057 F209 F719


0 1 0 OFF 2 0 1
START
NOT-
3 1 4 2 1 1 ON ON 1 3 NETZ
STROM
0
2 3 0 OFF 4

F059 F060 F062 F206 F718 F437 F119 F990


7/60 System overview
Small enclosures
CI-K Moeller HPL0211-2007/2008 http://catalog.moeller.net
Small enclosures, empty enclosures

General
Degree of protection IP65 (except CI-K2-80-A)
Five basic sizes (floor area of enclosure base)
Two mounting depths per base surface (exception: CI-K1
enclosure depth always 95 mm, CI-K2-80-. enclosure depth
1 always 80 mm)
Enclosure made of glass-fibre reinforced with self-extinguishing
polycarbonate, halogen free
Captive gasket
2 Enclosure base (RAL 9005)
Black (matt)
Enclosure cover RAL 7035, light grey (matt)

1 Metric cable entries 1


CI-K1 and CI-K2
1 metric cable entry knockouts with push-through cable entry
diaphragm in the sides, top and bottom and also in the rear wall

CI-K1H, CI-K2H:
metric cable entry knockouts in the enclosure sides, top and
bottom
CI-K3 to CI-K5:
metric cable entry knockouts in the sides, top and bottom and
also in the rear wall
Control cable entry from CI-K2
Metric cable glands to EN 50 262
Push-through metric cable grommets
a page 7/63, a page 13/35
3 Mounting systems for empty enclosures 2
Mounting rails to IEC/EN 60715
Sheet steel mounting plates
1 Accessories for mounting systems
a page 7/64
Mounting 3
Horizontal and vertical slot apertures for wall-mounting
enclosures
Captive cover screws
CI-K1 and CI-K2 with rubber feet on the back plate to
3 compensate for uneven walls
External mounting brackets for CI-K4 and CI-K5
3 a page 7/51
Mounting units
Miniature circuit-breakers
Rotary switch
Switch-disconnectors
Contactors
easy control relays
Timing relays
Control circuit devices

Laser labelling
We can label the cover surface of the CI-K small enclosures
according to your specifications. Wipe-resistant and permanent
with modern laser labelling method.
Please contact your sales office.
CI-K combination-* a page 7/62
Approved enclosures for use in UL/CSA a page A1/40
Cutouts in enclosure covers
We can produce cutouts in enclosure covers to your
requirements.
Please contact your sales office.
Ordering 7/61
Basic enclosures
http://catalog.moeller.net Moeller HPL0211-2007/2008 CI-K1, CI-K2, CI-K3

Small enclosures, empty enclosures


Dimensions Enclosure depth: Dimensions from top Features Part no. Price Std. pack
1. Mounting depth for mounting plate Article no. see price list
2. Mounting depth for mounting rails,
7.5 mm height
3. Enclosure depth

mm mm

CI-K basic enclosures


Degree of protection IP65 (Exception: CI-K2-80-A), material glass-fibre reinforced polycarbonate
Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey
Metric cable entry knockouts top, bottom and in the back plate
Push-through cable membrane on CI-K1 and CI-K2
Hard metric knockouts for sizes CI-K1H and CI-K2H
Hard metric knockouts from sizes CI-K3 to CI-K5
Two protective covers to protect the push-through cable membrane with CI-K1 and CI-K2
Control cable entry from CI-K2
Lamp indicator L-. can be mounted in base knock-out M20/M25
L With mounting rail CI-K1-95-TS 1 off
206881
72
With mounting rail CI-K1H-95-TS
120
82

S
105853
L
80 95

M With mounting rail CI-K2-100-TS


206882
79
With mounting rail CI-K2H-100-TS
160
116

T 73
229304
With mounting plate CI-K2-100-M
Q 206893
100 100 With mounting plate CI-K2H-100-M
229306
M With mounting rail CI-K2-145-TS
206883
124
With mounting rail CI-K2H-145-TS
160
116

T 118 229305
With mounting plate CI-K2-145-M
Q 206894
100 145 With mounting plate CI-K2H-145-M
229307
With adapter plate Prepared for fitting a CI-K2-145-AD
DILE contactor with ZE overload relay 207632

With adapter plate Prepared for fitting a CI-K2H-145-AD


DILE contactor with ZE overload relay 229308

N With mounting rail CI-K3-125-TS


206884
98 With mounting plate CI-K3-125-M
206895
200
152

U 93

R
120 125

N With mounting rail CI-K3-160-TS


206885
133 With mounting plate CI-K3-160-M
206896
200
152

U 128

R
120 160

Notes Number and size of cable entries a page 7/63


7/62 Ordering
Basic enclosures
CI-K4, CI-K5 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Small enclosures, empty enclosures

Dimensions Enclosure depth: Dimensions from top Features Part no. Price Std. pack
1. Mounting depth for mounting plate Article no. see price
2. Mounting depth for mounting rails, list
7.5 mm height
3. 7.5 mm mounting depth with mounting
rails

mm mm

CI-K basic enclosures


Degree of protection IP65 (Exception: CI-K2-80-A), material glass-fibre reinforced polycarbonate
Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey
Metric cable entry knockouts top, bottom and in the back plate
Push-through cable membrane on CI-K1 and CI-K2
Hard metric knockouts for sizes CI-K1H and CI-K2H
Hard metric knockouts from sizes CI-K3 to CI-K5
Two protective covers to protect the push-through cable membrane with CI-K1 and CI-K2
Control cable entry from CI-K2
Lamp indicator L-. can be mounted in base knock-out M20/M25
O With mounting rail CI-K4-125-TS 1 off
206886
98
With mounting plate CI-K4-125-M
206897
240
194

V 93

O
160 125

With mounting rail CI-K4-160-TS


206890
133 With mounting plate CI-K4-160-M
206898
128

160

P With mounting rail (weight of CI-K5-125-TS


fitted components max. 0.65 kg, 206891
with additional mounting plate 1.7
98
kg)
With mounting plate CI-K5-125-M
234
280

W 93
206899

P
200 125

With mounting rail (component CI-K5-160-TS


weight max. 0.65 kg, with 206892
additional mounting plate 1.7 kg)
133
With mounting plate CI-K5-160-M
128
206900

160

Customized cutouts and laser inscriptions


Only with enclosure cover
The necessary data (laser data, symbols, text and their respective positions) as well as the position of the cut-
outs must be provided as a DXF file.
CI-K1-COMBINATION-* 1 off
102060
CI-K2-COMBINATION-*
102061
CI-K3-COMBINATION-*
102062
CI-K4-COMBINATION-*
102063
CI-K5-COMBINATION-*
102064

Notes Number and size of cable entries a page 7/63


Ordering 7/63
Basic enclosures
http://catalog.moeller.net Moeller HPL0211-2007/2008 CI-K2

Small enclosures, empty enclosures


Dimensions Enclosure depth: Dimensions from top Features Part no. Price Std. pack
1. Enclosure depth Article no. see price list
2. Mounting depth for mounting plate
3. Mounting depth for mounting rail,
7.5 mm height

mm mm

Basic enclosure CI-K2


Degree of protection IP30, glass-fibre reinforced polycarbonate material
Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey
Metric cable entry knockouts top, bottom and in the back plate
Push-through cable entry diaphragm with CI-K2
Hard metric knockouts on CI-K2H
Two protective covers to protect the push-through cable membrane with CI-K2
Control cable entry
L-... indicator lights can be fitted in M20/M25 knockout in base
M with cover cutout Standard cutout dimensions and mounting CI-K2-80-A 1 off
rail for devices requiring 2 to 4 space units. 211107
T Push-through cable entry membrane.
46
Close off unused space units (max. 2) using
160

blanking strips VST1, a page 7/65

Q with hinged Standard cutout dimensions and mounting CI-K2H-80-A 1 off


100
80 cover rail for devices requiring 2 to 4 space units. 229309
Hard metric knockouts. Close off unused
space units (max. 2) using blanking strips
VST1, a page 7/65

M with cover cutout Transparent hinged cover for devices CI-K2-80-K 1 off
requiring 2 to 4 space units. Push-through 211108
T cable entry diaphragm.
70
160

with hinged Transparent hinged cover for devices CI-K2H-80-K 1 off


cover requiring 2 to 4 space units. Hard metric 229310
Q cable entry knockouts.
80
100
115

Notes Membrane grommets, cable glands a page 13/35

L M N O P Q R

Knockouts Knockouts Knockouts Knockouts Knockouts Knockouts Knockouts


2 x M20 or push- 2 x M25 or push- 2 X M25/20 2 X M32/25 2 X M50/40/25 2 x M25 or push- 2 X M25/20
through membrane up through membrane up 1 X M20 1 X M20 through membrane up 1 X M20
to max. o 12 mm to max. o 16 mm to max. o 16 mm and
CI-K2H: 2 x M25/20 1 push-through mem-
brane up to o 8 mm
CI-K2H: 2 x M25/20
S T U V W

Back plate: Back plate: Back plate: Back plate: Back plate:
2 x push-through mem- 2 x push-through mem- 2 X M25/20 2 X M32/25 2 X M50/40/25
brane up to max. o 8 brane up to max. o 11
mm mm
(not for CI-K2H)
7/64 Ordering
Accessories
TS-CI, M-CI Moeller HPL0211-2007/2008 http://catalog.moeller.net
Small enclosures, empty enclosures

For use with Mounting position Features Useful length Part no. Price Std. pack
Article no. see price list
mm

Mounting rails to IEC/EN 60715


Height 7.5 mm, with fixing screws

7.5

CI-K1 Crosswise 60 TS-CI-K1 10 off


206901
CI-K2 Crosswise 82 TS-CI-K2
206902
CI-K3 Lengthwise and crosswise 98 TS-CI-K3
206903
CI-K4 Crosswise 133 TS-CI-K4
206904
CI-K5 Lengthwise and 173 TS-CI-K5
crosswise, CI-K4 206905
lengthwise
Mounting plates
2 mm steel with fixing screws

CI-K2 M-CI-K2 10 off


206906
CI-K3 M-CI-K3
206907
CI-K4 M-CI-K4
206908
CI-K5 M-CI-K5
206909
Accessories for mounting systems
Spacers
For raising mounting systems in CI-K3 to CI-K5
(4 off required for mounting plate, 2 off required for mounting rail)
by 25 mm HS25-CI 25 off
002291
by 50 mm HS50-CI 25 off
002292
by 10 mm ADT200-190 10 off
002289
by 15 mm ADT125-110 10 off
002290
Hank nuts
To secure devices to mounting plate
7

M4 thread BT7488 100 off


088380
M5 thread BT7477 100 off
086007
Ordering 7/65
Accessories
http://catalog.moeller.net Moeller HPL0211-2007/2008 K-CI, SK-CI

Rotary switches, switch-disconnectors


For use with For use with Terminal capacities Part no. Price Std. pack
flexible Article no. see price list
mm2

Accessories for CI-K small enclosures


External fixing bracket kit
To secure CI-K4 and CI-K5 directly on the wall. Each kit contains 4 brackets.
T5B-.../I4, AB-CI-K4/5 1 off
T5-.../I5, 206914
P3-63/I4,
P3-100/I5,

Mounting rail adapter, screw fixing


To secure enclosure on mounting rails to IEC/EN 60715
CI-K1 TB-CI-K 1 off
206918

Blanking strips
To blank off one space unit; cannot be removed from outside
CI-K2-80-A VST1 5 off
211258

N terminals, PE terminals
Can be screwed onto support bosses in enclosure base plate
CI-K2-PKZ0-... 1 4 mm2 K-CI-K1/2 20 off
CI K1/2 207451

Insulated individual terminals


With PE, N adhesive labels
For snap-fitting onto mounting rail
CI-K3 1 10 mm2 K-CI-K3 20 off
206915
CI-K4 T5B-.../I4, 1.5 16 mm2 K-CI-K4 20 off
Cl-K4-T5B-... 206916
P3-.../I4
CI-K5 T5-.../I5, 10 35 mm2 K-CI-K5 20 off
CI-K5-T5-... 218488
P3-.../I5
Protective covers for push-through cable membrane with CI-K1(2)
To cover the push-through cable membrane
CI-K1 (M20) SK-CI-K1 100 off
226766
CI-K1 (M25) SK-CI-K2 100 off
226767
7/66 Ordering
Accessories
CI Moeller HPL0211-2007/2008 http://catalog.moeller.net
Small enclosures, empty enclosures

Dimensions Features For use with Enclosure depth Part no. Price Std. pack
Article no. see price
mm mm list

CI-B, C, D basic enclosures


Transparent cover
Metric knockouts top, bottom
With PEN terminal
IP55 individual enclosure with pre-drilled mounting plate
L DIL00AM CI-B 5 off L
024315
110
149

Knockouts
L 128
2 X M20
87

S27 CI-C 2 off


L
031434
110
165

L 128
110

L DIL0AM CI-D 2 off


S27 038553

110
222

L 128
110

Hank nuts
To secure devices to mounting plate
M4 thread BT7488 100 off
088380
7

M5 thread BT7477 100 off


086007
PE terminal (5th conductor)
Rated current 25 A
For o 1.5 6 mm2 solid
CI-B K6/1 100 off
CI-C 002270
CI-D
Technical data 7/67
Switch-disconnectors
http://catalog.moeller.net Moeller HPL0211-2007/2008 P1, P3

Rotary switches, switch-disconnectors


P1-25 P1-32 P3-63 P3-100
General
Standards IEC/EN 60 947, VDE 0660, IEC/EN 60 204, CSA,UL Switch-
disconnectors to IEC/EN 60 947-3
Lifespan, mechanical Operations x 106 0.3 0.3 0.1 0.1
Maximum operating frequency Operations/h 50 50 50 50
Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to
IEC 60068-2-30
Ambient temperature Open C -2550 -2550 -2550 -2550
Enclosed C -2540 -2540 -2540 -2540
Mounting position As required As required As required As required
Mechanical shock resistance (IEC/EN Half-sinusoidal shock, 20 ms g 15 15 15 15
60068-2-27)
Contacts
Rated operational voltage Ue V AC 690 690 690 690
Rated impulse withstand voltage Uimp V AC 6000 6000 6000 6000
Overvoltage category/pollution degree III/3 III/3 III/3 III/3
Rated uninterrupted current Iu A 25 32 63 100
Load rating with intermittent operation, AB 60 % DF x Ie 1.3 1.3 1.3 1.3
class 12 AB 40 % DF x Ie 1.6 1.6 1.6 1.6
AB 25 % DF x Ie 2 2 2 2
Short-circuit rating Fuse A gG/gL 25 50 80 100
Rated short-time withstand current (1 s current) Icw Arms 640 640 1260 2000
Isolating characteristics to IEC/EN 60947 V AC 690 690 690 690
Safe isolation to VDE 0106 Part 101 and Part 101/A1
Safe isolation to VDE 0106 Part 101 and Part 101 A1 between auxiliary V AC 440 440 440 440
contacts and main contacts
Switching angles 90 90 90 90
Contacts Number max. 3 (+N) max. 3 (+N) max. 3 (+N) max. 3 (+N)
Current heat loss per contact at Ie W 1.1 1.8 4.5 7.5
Terminal capacities
Solid or stranded mm2 1 x (1.5 6) 1 x (1.5 6) 1 x (2.5 35) 1 x (2.5 35)
2 x (1.5 6) 2 x (1.5 6) 2 x (2.5 10) 2 x (2.5 10)
Flexible with ferrule to DIN 46228 mm2 1 x (1 4) 1 x (1 4) 1 x (1.5 25) 1 x (1.5 25)
2 x (1 4) 2 x (1 4) 2 x (1.5 6) 2 x (1.5 6)
Terminal screw M4 M4 M5 M5
Tightening torque Nm 1.6 1.6 3 3
Switching capacity
Alternating voltage
Rated making capacity cos v = 0.35 A 240 320 800 950
Rated breaking capacity, motor load 230 V A 190 260 640 760
switch cos v = 0.35 400/415 V A 150 300 600 740
500 V A 170 290 590 880
690 V A 150 250 340 520
Rated operational current 440 V load-break switch AC-21A Ie A 25 32 63 100
AC-3 motor load switch motor rating 230 V P kW 5.5 7.5 15 22
400/415 V P kW 7.5 13 30 37
500 V P kW 7.5 18.5 30 45
690 V P kW 7.5 15 30 37
AC-23A Motor load switches (main 230 V P kW 7 8.5 18.5 30
switches maintenance switches) 400/415 V P kW 13 15 37 50
500 V P kW 11 18.5 37 65
690 V P kW 11 18.5 30 45
DC
DC-1, Load-break switches L/R = 1 ms Rated operational current Ie A 25 32 63 100
Voltage per contact pair in series V 60 60 60 60
DC-23A, motor load switch 24 V Rated operational current Ie A 25 25 50 50
L/R = 15 ms Contacts Quantity 1 1 1 1
48 V Rated operational current Ie A 25 25 50 50
Contacts Quantity 2 2 2 2
60 V Rated operational current Ie A 25 25 50 50
Contacts Quantity 3 3 3 3
120 V Rated operational current Ie A 12 12 25 25
Contacts Quantity 3 3 3 3
Notes Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft
The rated uninterrupted current Iu is stated at max. connected cross-section.
For terminal capacity solid, stranded and flexible:
Max. 2 cross-section sizes difference admissible when using 2 conductors.
7/68 Technical data
Switch-disconnectors
P5 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

P5-125 P5-160 P5-250 P5-315

General
Standards IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA,
UL switch disconnector according to IEC/EN 60947-3
Lifespan, mechanical Operations x 106 0.1 0.1 0.08 0.08

Maximum operating frequency Operations/h 50 50 50 50


Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC
60068-2-30
Ambient temperature Open C -2550 -2550 -2550 -2550
Enclosed C -2540 -2540 -2540 -2540
Mounting position As required As required As required As required
Contacts
Rated operational voltage Ue V AC 690 690 690 690
Rated impulse withstand voltage Uimp V AC 8000 8000 8000 8000
Overvoltage category/pollution degree III/3 III/3 III/3 III/3
Rated uninterrupted current Iu A 125 160 250 315
Load rating with intermittent AB 60 % DF x Ie 1.3 1.3 1.3 1.3
operation, class 12 AB 40 % DF x Ie 1.6 1.6 1.6 1.6
AB 25 % DF x Ie 2 2 2 2
Short-circuit rating Fuse A gG/gL 125 160 250 315
Rated short-time withstand current (1 s current) Icw Arms 2500 3000 4600 5800
Isolating characteristics to IEC/EN 60947 V AC 690 690 690 690
Safe isolation to VDE 0106 Part 101 and Part 101/A1
Safe isolation to VDE 0106 Part 101 and Part 101 A1 between V AC 440 440 440 440
auxiliary contacts and main contacts
Switching angles 90 90 90 90
Contacts Number max. 3 (+N) max. 3 (+N) max. 3 (+N) max. 3 (+N)
Current heat loss per contact at Ie W 8 10 13 16
Terminal capacities
Solid or stranded mm2 1 x (10 95) 1 x (10 95) 1 x (16 185) 1 x (16 185)
2 x (10 35) 2 x (10 35) 2 x (16 70) 2 x (16 70)
Copper band, 1 band Number of mm 6 x 9 x 0.8 6 x 20 x 1
segments x
width x
thickness
Copper band, 2 bands mm 6 x 9 x 0.8 6 x 9 x 0.8
Flexible with ferrule to DIN 46228 mm2 1 x (16 70) 1 x (16 70) 1 x (25 120) 1 x (25 120)
2 x (16 25) 2 x (16 25) 2 x (25 50) 2 x (25 50)
Terminal screw Allen screw 5 Allen screw 5 Allen screw 6 Allen screw 6
Tightening torque Nm 14 14 16 16

Notes Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft
The rated uninterrupted current Iu is stated at max. connected cross-section.
For terminal capacity solid, stranded and flexible:
Max. 2 cross-section sizes difference admissible when using 2 conductors.
Technical data 7/69
Switch-disconnectors, auxiliary contacts
http://catalog.moeller.net Moeller HPL0211-2007/2008 P5

Rotary switches, switch-disconnectors


P5-125 P5-160 P5-250 P5-315

Switching capacity
Alternating voltage
Rated making capacity cos v = 0.35 A 850 1050 1700 2050
Rated breaking capacity, motor load 230 V A 800 900 1600 1800
switch cos v = 0.35 400 V A 750 850 1380 1650
500 V A 650 850 1250 1550
690 V A 340 340 400 400
Rated operational current 440 V load-break switch AC-21A Ie A 125 160 250 315
AC-3 motor load switch motor rating 230 V P kW 22 30 37 45
400 V P kW 37 45 55 75
690 V P kW 30 37 45 45
AC-23A Motor load switches (main 230 V P kW 30 30 37 55
switches maintenance switches) 400 V P kW 45 55 90 110
690 V P kW 37 37 45 45
DC
DC-1, Load-break switches L/R = 1 ms Rated operational current Ie A 125 160 250 315
DC-1, Load-break switches L/R = 1 ms Voltage per contact pair in series V 42 42 42 42

DC-23A, motor load switch 24 V Rated operational current Ie A 125 160 250 315
L/R = 15 ms Contacts Quantity 3 3 3 3
48 V Rated operational current Ie A 125 160 250 315
Contacts Quantity 3 3 3 3
60 V Rated operational current Ie A 125 160 250 315
Contacts Quantity 3 3 3 3
120 V Rated operational current Ie A 40 50 80 100
Contacts Quantity 3 3 3 3

Notes Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft
The rated uninterrupted current Iu is stated at max. connected cross-section.
For terminal capacity solid, stranded and flexible:
Max. 2 cross-section sizes difference admissible when using 2 conductors.

HI...-P1(P3)... HI...-P5...

Auxiliary contacts
Standards Control circuit isolators to IEC/EN 60947-5f

Rated insulation voltage Ui V AC 500 500


Rated uninterrupted current Iu A 10 10
Rated operational current
AC-15 with 230 V Ie A 6 6
380 V/415 V Ie A 3
DC-13
125 V Ie A 1.1 0.23
250 V Ie A 0.55 0.1
Short-circuit rating
Maximum fuse A gG/gL 10 10
Terminal capacities
Solid mm2 0.75 2.5 0.75 2.5
Flexible with ferrule to DIN 46228 mm2 0.5 1.5 0.5 2.5
Tightening torque Nm 0.6 0.8
Control circuit reliability at 24 V DC, 10 mA Fault probability HF < 10 -5, < 1 fault in 100 000 operations
7/70 Technical data Technical data 7/71
Rotary switch Rotary switch
T Moeller HPL0211-2007/2008 http://catalog.moeller.net http://catalog.moeller.net Moeller HPL0211-2007/2008 T
Rotary switches, switch-disconnectors

Rotary switches, switch-disconnectors


T0-... T3-... T5B-... T5-... T6-3-8212/E/HI12 T6-160-... T8-...

General
Standards IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnectors to IEC/EN 60947-3 Switch-disconnectors to IEC/EN 60947-3
Load-break switches to IEC/EN 60947-3 Load-break switches to IEC/EN 60947-3
Lifespan, mechanical Operations x 106 1 0.5 0.5 0.5 0.1 0.1 0.1
Maximum operating frequency Operations/h 3000 3000 3000 3000 50 50 50
Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
cyclical, to IEC 60068-2-30
Ambient temperature
Open C 2550 2550 2550 2550 2550 2550 2550
Enclosed C 2540 2540 2540 2540 2540 2540 2540
Mounting position As required As required As required As required As required As required As required
Mechanical shock resistance to IEC 60068-2-27 Half-sinusoidal g > 15 > 15 > 15 > 15
shock 20 ms
Contacts
Rated operational voltage Ue V AC 690 690 690 690 690 690 690
Rated impulse withstand voltage Uimp V AC 6000 6000 6000 6000 6000 8000 8000
Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3 III/3
Rated uninterrupted current
open Iu A 20 32 63 100 125 160 315
Enclosed Iu A 20 32 63 100 125 160 275
Load rating with intermittent operation, class 12
AB 25 % DF x Ie 2 2 2 2 2 2 2
AB 40 % DF x Ie 1.6 1.6 1.6 1.6 1.6 1.6 1.6
AB 60 % DF x Ie 1.3 1.3 1.3 1.3 1.3 1.3 1.3
Short-circuit rating
Fuse A gG/gL 20 35 80 100 200 160 315
Rated short-time withstand current (1 s current) Icw Arms 320 650 1300 1850 2000 3000 4200
Safe isolation to VDE 0106 Part 101 and Part 101/A1
between the contacts V AC 440 440 440 440
Switching angles 90 90 90 90 90 90 90
60 60 60 60 60 60 60
45 45 45 45
30 30 30 30
Contact units 11 11 10 10 3 3 3
Double-break contacts max. 22 max. 22 max. 20 max. 20 max. 6 max. 6 max. 6
Current heat loss per contact at Ie W 0.6 1.1 4.5 7.5 11 11 11
Terminal capacities
Solid or stranded mm2 1 x (1 2.5) 1 x (1 6) 1 x (2.5 35) 1 x (2.5 35) 1 x 70 1 x 95 150
2 x (1 2.5) 2 x (1 6) 2 x (2.5 16) 2 x (2.5 16) 2 x 25 2 x 25
Flexible with ferrule to DIN 46228 mm2 1 x (0.75 1.5) 1 x (0.75 4) 1 x (1.5 25) 1 x (1.5 25) 1 x 50 1 x 50 120
2 x (0.75 1.5) 2 x (0.75 4) 2 x (1.5 10) 2 x (1.5 10) 2 x 16 2 x 16
Flat conductor connection with busbars mm2 1 x (25 x 5)
2 x (20 x 3)
Terminal screw M3.5 M4 M6 M6 M6 M5, Allen key M12
Tightening torque Nm 1 1.6 4 4 5.6 14 25

Notes For mechanical shock resistance: T3.../I... >12g


Applies to T0(3).../SVB: isolating characteristics to IEC/EN 60947 Ufor rated operational voltage up to 500 V AC
Applies to rated uninterrupted current Iu of the contact: with T5-4-8344/I5 max. 95 A
For terminal capacity solid, stranded and flexible:
T0(3), (6), (8)...: Maximum of 2 cross-section sizes difference admissible between 2 conductors
T5(B)-...: Maximum of 1 cross-section size difference admissible between 2 conductors
For type T8-3-8342/... the following applies: switching angle = 90 and flat connection = 1 busbar 25 x 5 or 2 busbars 20 x 3
7/72 Technical data Technical data 7/73
Rotary switch Rotary switch
T Moeller HPL0211-2007/2008 http://catalog.moeller.net http://catalog.moeller.net Moeller HPL0211-2007/2008 T
Rotary switches, switch-disconnectors

Rotary switches, switch-disconnectors


T0-... T3-... T5B-... T5-... T6-3-8212/E/HI12 T6-160-... T8-...

Switching capacity
Alternating voltage
Rated making capacity cos v = 0.35 A 130 320 800 950 1600 1600 2390
Rated breaking capacity, motor load 230 V A 100 260 520 760 1280 1280 1910
switch cos v = 0.35 400 V A 110 260 600 740 900 900 1800
500 V A 80 240 480 590 880 880 1200
690 V A 60 170 340 420 340 340 420
Rated operational current 440 V load-break switch AC-21A Ie A 20 32 63 100 125 160 315
AC-3 motor load switch motor rating 230 V P kW 3 6.5 15 22 22 22 22
230 V Star-delta P kW 4 11 22 30 22 22 37
400/415 V P kW 4 12 22 30 37 45 55
400 V Star-delta P kW 5.5 18.5 37 45 37 45 55
500 V P kW 5.5 15 22 37 37 37 37
500 V Star-delta P kW 7.5 22 37 55 37 37 37
690 V P kW 4 15 22 30 22 22 37
690 V Star-delta P kW 5.5 22 37 45 22 22 37
AC-23A Motor load switches (main 230 V P kW 3.5 7.5 15 18.5 37 37 75
switches maintenance switches) 400/415 V P kW 6.5 13 22 30 45 55 132
500 V P kW 13 15 22 37 55 55 75
690 V P kW 22 30 30 30 37
Rated operational current control switch 230 V Ie A 6 10 16 16
AC-15 400/415 V Ie A 4 6 6 6
500 V Ie A 2 4 4 4
DC
DC-1, Load-break switches L/R = 1 ms Rated operational current Ie A 10 25 63 80 125 125 315
Voltage per contact pair in series V 60 60 60 60 42 42 42
DC-21A Rated operational current 240 V Ie A 1 1

240 V Contacts Quantity 1 1


DC-23A, motor load switch 24 V Rated operational current Ie A 10 25 50 125 125 250
L/R = 15 ms Contacts Quantity 1 1 1 1 1 1
48 V Rated operational current Ie A 10 25 50 125 125 250
Contacts Quantity 2 2 2 2 2 2
60 V Rated operational current Ie A 10 25 50 125 125 125
Contacts Quantity 3 3 3 3 3 3
120 V Rated operational current Ie A 5 12 25 50 50 50
Contacts Quantity 3 3 3 3 3 3
240 V Rated operational current Ie A 5 5 20
Contacts Quantity 5 5 6
DC-13, Control switches L/R = 50 ms Rated operational current Ie A 10 20 25 125 125 250
Voltage per contact pair in series V 32 32 24 24 24
Control circuit reliability at 24 V DC, 10 mA Fault probability HF < 10 -5, < 1 fault in 100000 operations < 10 -5, < 1 fault in 100000 operations

Auxiliary contacts
Standards Control circuit isolators to IEC/EN 60947-5f
Rated insulation voltage Ui V AC 500 500
Rated uninterrupted current Iu A 10 10
Rated operational current
AC-15 with 230 V Ie A 6 6
380 V/415 V Ie A 4 4
Short-circuit rating
Maximum fuse A gG/gL 10 10
Terminal capacities
Solid mm2 0.75 2.5 0.75 2.5

Flexible with ferrule to DIN 46228 mm2 0.5 1.5 0.5 1.5

Tightening torque Nm 0.35 0.35


Control circuit reliability at 24 V DC, 10 mA Fault probability HF < 10-5, < 1 fault in 100 000 operations
7/74 Technical data
Mini rotary switches
TM Moeller HPL0211-2007/2008 http://catalog.moeller.net

TM

General
Standards IEC/EN 60947, VDE 0660 UL, CSA
Control switches to IEC/EN 60947-5-1
Control circuit isolators to IEC/EN 60947-5-1
Mini rotary switches

Control circuit isolators (IEC/EN 60947-5-1) Maximum 6 contacts; switching angle 90


Lifespan, mechanical Operations x 106 1
Maximum operating frequency Operations/h 3000
Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat,
cyclical, to IEC 60068-2-30
Ambient temperature
Open C 2550
Enclosed C 2540
Mounting position As required
Terminal capacities
Solid mm2 1 x 1,5
2 x 1,5
Flexible without ferrule mm2 1 x 1,5
2 x 1,5
Solid or stranded AWG 1 x 14
2 x 14
Flexible AWG 1 x 16
2 x 16
Terminal screw M2.5
Tightening torque Nm 0.35
Contacts
Mechanical variables
Contacts Number Max. 16
Contact units 8
Switching angles 90
60
45
30
Min. switching angle for On-Off-On 60
Max. number of switch positions F 12
Thickness of gold coating mm 35
Electrical characteristics
Rated operational voltage Ue V AC 500
Rated impulse withstand voltage Uimp V AC 4000
Overvoltage category/pollution degree III/3
Rated insulation voltage Ui V AC 500
Rated insulation voltage for UL/CSA V AC 300
Rated uninterrupted current Iu A 10

Switching capacity
AC-23 Motor load switches 230 V AC, 3-pole kW 1.8
440 V AC, 3-pole kW 3
230 V AC, 1-pole kW 0.75
440 V AC, 1-pole kW 1.1
AC-15 Control switches 230 V AC, 1-pole A 2.5

400 V AC, 1-pole A 1.5


440 V AC, 1-pole A 1
DC-1 Load-break switches 1 24 V DC A 10
110 240 V DC A 0.7 0.3
DC-13, Control switches L/R = Rated operational current Ie A 3
50 ms

Voltage per contact pair in series V 32


Switching capacity (UL489, 240 V AC, 3-pole HP 1
CSA 22.2 No. 5.1) 277 V AC, 1-pole HP o
300 V AC Heavy duty A 10
Max. short-circuit protective device
Fuse A gG/gL 10
Control circuit reliability at 24 V DC, 10 mA Fault HF < 10-5, < 1 fault in 100000 operations
probability
Technical data 7/75
Small enclosures
http://catalog.moeller.net Moeller HPL0211-2007/2008 CI-K

Small enclosures, empty enclosures


CI-K1 CI-K2 CI-K3 CI-K4 CI-K5

General
Standards IEC/EN 60529
DIN 43660
EN 50262
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature C 2570
Ambient temperature with push-through cable entry C 2540
Protection type IP 65 IP 65 IP 65 IP 65 IP 65
Degree of protection with push-through cable entry IP 65 IP 65 IP 65 IP 65 IP 65
Dissipatable heat loss a Chapter 14, Technical data
Material characteristics
Material
Base, Cover Glass-fibre reinforced polycarbonate
Surface treatment Resistant to corrosion
Colour
Base RAL 9005, black (matt)
Cover Enclosure cover RAL 7035, light grey (matt)
Material properties
Electrical
Creepage resistance to IEC 60112
Base CTI175
Cover CTI175
Surface resistance to IEC 60093 O x 1013 1
Dielectric strength to IEC 60243-1 kV/mm 30
Thermal
Continuous thermal stability
Enclosures C -40120
Gasket C -4080
Mechanical
IK code to EN 50102 Please enquire
Weight of components fitted
per mounting rail kg 0.2 0.7 0.85 0.75 0.65
with mounting plate kg 0.85 0.9 1
Chemical resistance
Base, Cover
Resistant Acids < 10 %, mineral oil, petrol, grease, saline solution
Partially resistant Acids > 10 %, alcohol
Not resistant Alkalis, benzol
Push-through membrane (CI-K1/CI-K2) and sealing material
Resistant Acids < 10 %, alkalis,
alcohol, saline solution
Partially resistant Acids < 10 %, grease, benzol

Not resistant Mineral oil, petrol


Atmospheric
Saline spray IEC 60068-2-11
UV resistance Beneath protective shield
Water consumption to DIN EN ISO 62 % 0.29 0.29 0.29 0.29 0.29
Flammability characteristics
Glow wire test
Base, Cover
Glow wire to VDE 0471 Part 2 C Thickness 960/1 mm
to UL 94 VO/1.5 mm thick
Push-through membrane (CI-K1/CI-K2) and sealing material

To IEC 2 C 650/1 mm thick


to UL 94 HB
Halogen free Yes
7/76 Dimensions
Rotary switch
T0, T3 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Flush mounting

T0.../E (+ H3-T0) Drilling dimensions


T3.../E (+ H3-T0)

H3-T0 3.1 3.5


25 101 5
b

10 11
17

90

30
48

12.2

48
c20 35 75

Centre mounting

T0.../EZ Drilling dimensions


T3.../EZ T0 T3
3.2
b 1.5 5
17

24.1 +0.4
0
45
48

54
48

+0.4
22.3 0

48 61
48
c21 35

Part no. c20 c21 Part no. c20 c21


T0-1... 41 61 T3-1... 44 64
T0-2... 50 70 T3-2... 56 76
T0-3... 60 80 T3-3... 67 87
T0-4... 69 89 T3-4... 79 99
T0-5... 79 99 T3-5... 90 110
T0-6... 88 108 T3-6... 102 122
T0-7... 98 118 T3-7... 113 133
T0-8... 107 127 T3-8... 125 145
T0-9... 117 137 T3-9... 136 156
T0-10... 126 146 T3-10... 148 168
T0-11... 136 156 T3-11... 159 179
One contact unit depth 9.5 mm One contact unit depth 11.5 mm

Not included as standard

Service distribution board mounting

T0.../IVS Drilling dimensions


base

c22
5 55 48
5
55
45

50
45

60

50

M4

54 28 5
Dimensions 7/77
Rotary switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3

Rotary switches, switch-disconnectors


Rear mounting
T0.../Z Drilling Drilling
T3.../Z dimensions dimensions
base door
Extension possible with ZAV-T0 F 4 x 25 = 100 mm
T0
b 5 5
O5
22. 5 5.5
3 +0
.4
17

0
a
M4

50

36
50
60
48

25 48 36
48
O5
T3
O5
22. 5 5.5
3 +0
.4
0

c23
c24 35

55

65
75

65
M4

36
38, 54
100
R
63 36
O5

Part no. c20 c21 c22 c23 c24 c24 with c25 Part no. c20 c21 c22 c23 c24 c24 with c25
f/F F 4 ZAV f/F F 4 ZAV
T0-1... 41 61 77 48 86 102 202 72 T3-1... 44 64 80 51 86 105 205 79
T0-2... 50 70 87 57 96 112 212 72 T3-2... 56 76 92 63 101 115 216 79
T0-3... 60 80 96 67 105 121 221 91 T3-3... 67 87 103 74 112 128 228 101
T0-4... 69 89 106 76 115 131 231 91 T3-4... 79 99 115 86 124 139 239 101
T0-5... 79 99 115 86 124 140 240 T3-5... 90 110 126 97 135 151 251
T0-6... 88 108 125 95 134 150 250 T3-6... 102 122 138 109 147 162 262
T0-7... 98 118 134 105 143 159 259 T3-7... 113 133 149 120 158 174 274
T0-8... 107 127 144 114 153 169 269 T3-8... 125 145 161 132 170 185 285
T0-9... 117 137 154 124 162 178 278 T3-9... 136 156 172 143 181 196 296
T0-10... 126 146 163 133 172 188 288 T3-10... 148 168 184 155 193 208 308
T0-11... 136 156 173 143 181 197 297 T3-11... 159 179 195 166 204 219 319
One contact unit depth 9.5 mm One contact unit depth 11.5 mm

Not included as standard

Flush mounting main switch


T0.../EA/SVB Drilling dimensions
T3.../EA/SVB door
b F5 T0 3.1 3.5
48
45
17

10 11
30

I ON
49
33

o
OFF

T3
o
OFF

12.2
54

25 c20
65 35
61

Rear mounting main switch


T0.../V/SVB Drilling Drilling
T3.../V/SVB dimensions dimensions
base door
b 5 5 5.5
22.
48 3 +0
.4
F5 0

5 25
T0
17

M4
50
60

50

36

I ON
33

o
OFF

49 36
o
OFF

5
65 c23
c24 35 T3
f 38, F 54 1 00 M4
65
75

65

Rf a

63
Interlock extension possible with ZVV-T0 + ZAV-T0, F 4 x 25 = 100 mm 5
Not included as standard
7/78 Dimensions
Rotary switches
T0, T3 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Surface mounting
T0.../I1
Drilling dimensions
base
M4

M20
137

120

127
80 c25 27

T3.../I2 Drilling dimensions


base
M4

171
M20 / M25
160
180

100 c25 c33

Surface mounting main switch Drilling dimensions


base
T0.../I1/SVB
M4

M20
I ON

127
137

120

o
OFF

o
OFF

80 c25 35

T3.../I2/SVB Drilling dimensions


base
F 3 padlocks
M4
d
b

8 d = 4 8 mm
b + d F 47 mm
171

I ON

M20 /M25
180

160

o
OFF

o
OFF

100 c25 35

Part no. c25 Part no. c25 c33


T0-1... 75 T3-1... 80 27
T0-2... 75 T3-2... 80 27
T0-3... 95 T3-3... 100 35
T0-4... 95 T3-4... 100 35
T3-5... 145 35
Dimensions 7/79
Rotary switches, switch-disconnectors, accessories
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3, P1, P3

Rotary switches, switch-disconnectors


Key operation

S-T0 T0.../E(I1) + S-(SOND-)T0 T0.../Z + S-(SOND-)T0 T0.../EZ T0../E + EZ-T0 + S-(SOND-)T0


S-SOND...-T0 T3.../E(I2) + S-(SOND-)T0 T3.../Z + S-(SOND-)T0 T3.../EZ T3../E + EZ-T0 + S-(SOND-)T0
b
25
17
48

5 5
19 27
27 36 30 44 22:25 28
c20 30:23 26
48 100
R

3.1 3.5 22 5 5.5


.3 +0
.4

10...11
0

12.5
36
3.2 3.2
30

17
36
12.2
22.3 + 0.4 30.5
0

Cylinder lock

SVA-T3 T0.../I1/SVA T0.../E/SVA... T0.../Z/SVA...


T3.../I2/SVA T3.../E/SVA... T3.../Z/SVA...
P1.../12/SVA P1.../E/SVA P1.../Z/SVA
b 56 56 56

73
73
73
73

46 30 46 30 46 30
48

Padlocking feature

SVC-T3 T0.../I1/SVC T0.../E/SVC... T0.../Z/SVC...


T3.../I2/SVC T3.../E/SVC... T3.../Z/SVC...
P1.../12/SVC P1.../E/SVC P1.../Z/SVC
b 56 56 56
73
73
73

73

48
48
48

46 46 46
48

Modules
Switched neutral N-P... F 3 padlocks
Auxiliary contact HI 11-P1/P3
a33
a3 d
b

d = 4 8 mm
H-P... b + d F 47 mm
b31

5 3 1 1 3 5
L3 L2 L1
N
HI 11
N
T3 T2 T1 N-P
6 4 2 2 4 6

a32 a31 a32 a32 a31 a32

Part no. a3 a31 a32 a33 b31


P1-... 49 15 15 83 49
P3-.. 72 18 15 114 60

Not included as standard


7/80 Dimensions
Rotary switches
T5B, T5 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Flush mounting Drilling dimensions


T5(B).../E door
b
18
4.1 4.5
27

I ON 12 13

37
o
88

86
OFF

14
88 F5
c2 37

Rear mounting Drilling dimensions Drilling dimensions


T5(B).../Z base door
a
b c20
F5
5 5.5
27

I ON

o M6

30

48
88

73
OFF

.5
25 25
88 48
c2 37

f 38, F 54
R f 100

Shaft extension possible with ZAV-P3 F 4 x 25 = 100 mm


Flush mounting main switch Drilling dimensions
T5(B).../EA/SVB door

88 b
F5
c2
4.1 4.5
27

25

I ON
12 13
o

37
88
88

OFF

o
OFF

80/90
80/90

44 14

40.5 100
16.5

Rear mounting main switch Drilling dimensions Drilling dimensions


T5(B).../V/SVB base door
b F5
c20
5
27

5 5.5

I ON

oOFF
88

48
30
73

.5

o
OFF

25 25
88 44 48

a
12 R f 100
16.5 40.5

Part no. c20 c2 c20 with c21 c22 Extension


f/F F 4 ZAV possible with ZVV-P3,
F 4 x 25 = 100 mm
T5(B)-1... 54 92 107 207 90 125 (95)
T5(B)-2... 71 109 124 224 90 125 (95) Not included as standard
T5(B)-3... 87 125 140 240 123 160 (160)
T5(B)-4... 104 142 157 257 123 160 (160)
T5(B)-5... 120 158 173 273
T5(B)-6... 137 175 190 290
T5(B)-7... 153 191 206 306
T5(B)-8... 170 208 223 323
T5(B)-9... 186 224 239 339
T5(B)-10... 203 240 356 356
One contact unit depth 16.5 mm

Rotary switches T5B and T5 are same size,


only thier contacts are different
Dimensions 7/81
Rotary switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T5B, T5

Rotary switches, switch-disconnectors


Surface mounting
T5B.../I4
T5.../I5

M25
M25 M50
M32 M20
240

280
M20

160 c22 29 200 c22 37

Surface mounting main switches

T5B.../I4/SVB Drilling dimensions


M5 F 3 padlocks
d

b
d = 4 8 mm
b + d F 47 mm

I ON
240

o
193

OFF

o
OFF

142

160 c22 44

T5.../I5/SVB Drilling dimensions


M5

I ON
280

o
233

OFF

o
OFF

182

200 c22 44

External fixing bracket


AB-CI-K415 Part no. c22
7.8 T5(B)-1... 125
T5(B)-2... 125
3.8
T5(B)-3... 160
T5(B)-4... 160
One contact unit depth 16.5 mm
t=3 M5

Rotary switches T5B and T5 are same size,


5.5

6.5
20

only thier contacts are different

6 36
52
7/82 Dimensions
Rotary switches
T6, T8 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Flush mounting

T6-3-8212/E/HI12
T8.../E/HI12

58
b2

a2 150 5
c2 c30

T6-160-6/V/SVB-SW/HI11 T8-3-8342/V/SVB-SW/HI11
6.4 H-T6-100 19
2

7
H-T8
118

88
68
108

130
68
76 93 9
4.5
2

224 216 73
200 104 172.8 9.2
5.5 130 315 86.5
1 218
0
R 10 250 7
5 1 0
R 10

Drilling dimensions
Part no. a2 b2 c2 c30 d1 d2 x1 y1 door
d2

T6-3-8212/E/HI12 88 88 152 44 26 30 6.0 68 68


T8.../E/HI12 130 130 173 62 22 25 7.0 104 104
T8.../SVB 26 30 7.0 68 68

y1
d1

x1

T6: 4 M5 x 20
T8: 4 M6 x 20

F 3 padlocks for T.../SVB


d
b

d = 4 8 mm
b + d F 47 mm
Dimensions 7/83
Switch-disconnectors
http://catalog.moeller.net Moeller HPL0211-2007/2008 P1, P3

Rotary switches, switch-disconnectors


Flush mounting Centre mounting
Drilling dimensions
Door
P.../E P1.../EZ P1-.../E P1-.../EZ
3.1 3.5 3.2 4.1 4.5

10 11

12.5
b22

5 3 1
I ON L3 L2 L1 12 13

37
30
b3
0
b2

OFF
T3 T2 T1
6 4 2
12.2 22.3 +0.4
0 14
a2 a3 5
c2 c21

P1.../EZ = c2 + 5 mm

Service distribution board mounting

P3.../IVS F 3 padlocks P1.../IVS


c3 5 c3
5 c23
d

b
c22 a32 a32 L1 L2 L3

L1 L2 L3 L1 L2 L3
d = 4 8 mm
b + d F 47 mm

45
b3
HI11
45
b3

N
T1 T2 T3

T1 T2 T3
a31 T1 T2 T3
49 28
a4
55

Rear mounting
Drilling dimensions
Bottom Door
P/Z P1/Z
5 5.5
5

36
M4
65
b22

22.3
+0.4
0

36
b3

c31 c32
b2

5
P3/Z
a2 a3 5 5.5

M4
75

48
30
.5

3 c21
c25
c20
100 25 48
38, 54 R

Shaft extension possible with ZAV-... F 4 x 25 = 100 mm

Part no. a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31
P1 48 49 53.5 65 48 87 15 15 83 48 70 65 17 180 32 49
P3 87 72 71.5 87 87 125 18 15 114 87 83 87 27 175 60

Part no. c2 c3 c20 c20 with c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
f/F F 4
ZAV/ZVV
P1 59 86 96 112 212 35 32 65 68 58 35 77 25 25 27
P3 59 82 103 118 218 37 41 63 81 65 44 90 25 25 29
7/84 Dimensions
Switch-disconnectors
P1, P3 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Flush mounting main switches


Drilling dimensions
Door
P/EA/SVB P1 P3
a22 b
H-P...
3.1 3.5 4.1 4.5
b22

10 11
b31
I ON 5 3 1

y
12 13
N
o
b21

30
b3

37
OFF

y
N

o
OFF

6 4 2

12.2 14

a21 a3
F5
25 c2 c27

Rear mounting main switches


Drilling dimensions
Bottom Door
P/V/SVB P1/V/SVB
c27 5 5.5
5 F5
b
a22
H-P... a

36
M4

65
+0.4
b22

22.3 0

36
b31

I ON 1 3 5

N P3/V/SVB
b21

o
b3

OFF

N 5 5.5
o
OFF

2 4 6

3
a21 a3 c25
c20 100 M4
75

48
30
Rf

.5
f 38, F 54

25 48
Interlock extension possible with ZVV-...+ZAV... F 4 x 25 = 100 mm
Not included as standard

Layout Surface mounting main switches/safety switches

P1.../I2/SVB Drilling dimensions


P1.../I2 P1.../I2/SI

M4

M25 M25
F8
M25
160

171
b23

a23 c28 c33 c27

Part no. a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31
P1.../I2 48 49 53.5 65 48 100 15 15 83 48 70 65 17 180 35.5 49

Part no. c2 c3 c20 c20 with c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
f/F F 4
ZAV/ZVV
P1... 59 86 96 112 212 35 32 65 68 58 35 80 25 25 27
Dimensions 7/85
Switch-disconnectors
http://catalog.moeller.net Moeller HPL0211-2007/2008 P5

Rotary switches, switch-disconnectors


Flush mounting

P5.../E Drilling dimensions


F5
M5

q 68
q 88
88
68

b
6
26 30
a 8 35
c

Flush mounting main switches

P5-.../EA/SVB(-SW)
M5 HI10
b2

88
68
88

q 88
b2

F5

a1 21 c 26
a2 a a2 49.3

Rear mounting

P5.../Z Drilling dimensions


6.4
2

q 68
q 88
b1

6
26 30

F5
2

a1 c 8 35
a c1

Rear mounting main switches

P5-.../V/SVB(-SW)
b2

88

q 88
b
b2

F5 26
100
Rf
a2 a a2 c
c1 49.3

Part no. a a1 a2 b b1 b2 c c1
P5-125/160 112 36 38 108 120 76 91 f 130 F 287
P5-250/315 145 44 52.5 126 144 88 98 f 140 F 280
7/86 Dimensions
Switch-disconnectors
P3 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors

Layout Surface mounting main switches/safety switches


P3-63/I4 P3-63/I4/SVB Drilling dimensions
P3-63/I4/SI
T5B-.../I4/SI
M5

M25
M32 M20

193
b23

142

a23 95 29 95 44

Layout Surface mounting main switches/safety switches


P3-100/I5 P3-100/I5/SVB Drilling dimensions
P3-100/I5/SI
T5-.../I5/SI
M5

M25
M50 M20

233
b23

182

a23 125 37 125 44

Part no. a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31
P3-63/I4 87 72 71.5 87 87 160 18 15 114 87 83 87 27 240 35.5 60
P3-100/I5 87 72 71.5 87 87 200 18 15 114 87 83 87 27 280 35.5 60

Part no. c2 c3 c20 c20 with c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
f/F F 4
ZAV/ZVV
P3-63 59 82 103 118 218 37 41 63 81 65 44 125 25 25 37
P3-100 59 82 103 118 218 37 41 63 81 65 44 125 25 25 37
Dimensions 7/87
Mini rotary switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM

Rotary switches, switch-disconnectors


Flush mounting

TM.../E Drilling dimensions

3
8

4.8
3.2
M3 M3

28
30

28 20

28
30 c20

Control circuit switches


for 2 padlocks 4 mm or 1 padlock 6 mm

TM-.../E/SVB(-SW) Drilling dimensions


3

10
4.2
M4 M4

38
48

28

30

38
48
c21 35

Centre mounting

TM-.../EZ Drilling dimensions1)

3.2

F 5.5 1.7
17/19

24.1 +0.4
0
17.9
16.2 +0.2
30

28

0 +0.4
22.3 0

30 c20 12 23

Centre mounting with key operation

TM-...+EZ/S-.. Drilling dimensions1)

17/19
5.5 3.2

1.7
24.1 +0.4
0
17.9
28
30

16.2 +0.2
0 +0.4
30 c20 12 35 22.3 0

Part no. c20 c21


TM-1... 39 42
TM-2... 51 54
TM-3... 63 66
TM-4... 75
TM-5... 87
TM-6... 99
TM-7... 111
TM-8... 123
One contact unit depth 12 mm

Service distribution board mounting

TM-.../IVS TM-.../IVS/S

Part no. c1 c2
TM-1... 44 21
45
60

45
60

TM-2... 46 26.5
One contact unit depth 12 mm

35.5 c1 c2 35.5 42 21.5 24

Note 1)) Drilling dimensions either 16.2 mm = without reduction RMQ16; 22.3 mm = with reduction RMQ Titan
7/88 Dimensions
Small enclosures
CI-K Moeller HPL0211-2007/2008 http://catalog.moeller.net
Small insulating material enclosures Mounting rails
easy Relay, easy Control, easy MFD

CI-K1...-95-TS TS-CI-K1

17.5

35
4.7 7.5
39 61

5 45 72
1.5

12
127
137
120
82

74
4.5 37.5 57.5 39
80 95

Mounting plates Mounting rails


CI-K2-... M-CI-K2 TS-CI-K2
Part no. a b
CI-K2-100-... 100 52.5

7.5
92

35
22

CI-K2-145-... 145 97.5


5.2 7.5
4.7
52 a
7
5 57 l
65
1.5

116
18

a l
77 92
100
116
160
171
181

4.5 47.5 b 46
100 a

52
22
20

Mounting plates Mounting rails


CI-K3-... M-CI-K3 TS-CI-K3
Part no. a b
CI-K3-125-... 125 74.5
35
108
24.5

7.5

CI-K3-160-... 160 109.5


5.2 7.5

5.3 a
70
116 l

5 65
a l
1.5

93 108
27
152
200
210
222

140

5.5 50.5 b 70
120 a

70
24.5
21
Dimensions 7/89
Small enclosures
http://catalog.moeller.net Moeller HPL0211-2007/2008 CI-K
Small insulating material enclosures Mounting plates Mounting rails

easy Relay, easy Control, easy MFD


CI-K4-... M-CI-K4 TS-CI-K4
Part no. a b
CI-K4-125-... 125 72.5

35
30
23
CI-K4-160-... 160 107.5

7.5
143.8
5.2 7.5
a
74 27 l

5.3 a l

5.6
90 128 143
154

193
154
240
194

80
1.5

5 52.5 72.5 72
160 125 142

CI-K5-... Mounting plates Mounting rails


M-CI-K5 TS-CI-K5
33.5

35
50.5

183
5.2 7.5

7.5
91 27 a
l
5.6

5.3
170
181
233
110
234

280
1.5

5 73.5 b 87
200 a 182

Typ a b a l
CI-K5-125-... 125 51.5 168 183
CI-K5-160-... 160 85.5

Basic enclosures
CI-B, CI-C, CI-D
c Part no. a a1 b b1 b2 b3 c c1 c2
c1
4,5 12 c2 CI-B 87 71 149 106 128 10.5 128 115 84.4
M4 CI-C 110 95 165 122 144 10.5 128 115 84.4
CI-D 110 97 222 179 201 10.5 128 115 84.4
b1
b2

b2
b

a1
b3

Вам также может понравиться