On-Off switches a 7/54 a 7/21 a 7/21 a 7/21 a 7/24 a 7/21 a 7/22 a 7/22 a 7/22 a 7/22 a 7/22 a 7/22 a 7/22
Safety switches with warning label a 7/30 a 7/30 a 7/30 a 7/30 a 7/30 a 7/30
Changeover switches a 7/25 a 7/25 a 7/26 a 7/26 a 7/26 a 7/26
Reversing switches with 0 (Off) position a 7/32 a 7/32 a 7/32
Star-delta switches a 7/33 a 7/33 a 7/33
Reversing star-delta switches a 7/33 a 7/33 a 7/33
Multi-speed switches a 7/34 a 7/34 a 7/34
Reversing multi-speed switches a 7/33 a 7/33 a 7/33
Control switches
Step switches a 7/56 a 7/35
On-Off switches a 3/37
Changeover switches a 7/55 a 3/37
Hand/Auto switches a 7/55 a 3/37
Spring-return switches a 7/39
Universal control switch a 7/39
Coding switches a 7/58 a 7/40
Series switches a 7/40
Instrument selector switches a 7/40
Group switches a 7/58
On-Off switches, spring-return a 7/58
Reversing switches a 7/58
Switches with interlocks
Panic switchs without Emergency-Stop function a 7/41 a 7/41 a 7/41
On-Off switches without Emergency-Stop function a 7/42 a 7/42 a 7/41
Non-standard switches a Electronic catalogue, http://catalog.moeller.net a Electronic catalogue, http://catalog.moeller.net
Mounting form
Surface mounting /I
ATEX
Rear mounting /Z
2
1
10
10
ATEX
5
9
9
8
8
7
6
7
6
ATEX
4
10
10
9
9
System overview 7/5
Rotary switch
http://catalog.moeller.net Moeller HPL0211-2007/2008
4
1
2
11
5
3 ATEX
11
6
10
ON OFF switches P5
3
4
2 12
12 13
4
13
4
4
7
8
8
10
10
System overview 7/7
Switch-disconnectors
http://catalog.moeller.net Moeller HPL0211-2007/2008 P
Front IP65
IEC/EN 60 947-5-1
"One man mounting" by centre fixing
ATEX
Fixing either by snap-on or screw fixing
a page 7/21 a page 7/43
for snap fitting to EN 50022 top-hat rail
Add-on modules 4 Main switch (mounting kit) for use as 7
Drive coupling in door or cover Switchable N conductor (early operation N/O Emergency-Stop device
contact)
Connection from front Auxiliary contacts To IEC/EN 60204-1, VDE 0113 Part 1
2 modules can be retrofitted Fingerproof With red rotary handle and yellow lokking ring
Neutral terminal 13
Flush mounting, left
Service distribution board mounting, right
a page 7/48
7/8 Description
Key to part numbers, modular system
T0, T3, T5, T5B Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Rotary switches can be used for many switching and The switch chamber (contact unit = BE) contains 1 or T rotary switches and P switch-disconnectors are
control applications. For example as ON-OFF 2 contacts In our catalogue T Rotary Switches" are manufactured without PCB, CFC, asbestos and silicon.
switches, main switches, main/control switches, over 800 standard circuits (Please order under The contacts are free from cadmium.
instrument switches. The switch consists of a hand K115D/F/GB. Article number 077643). On the
actuator, the switch unit and the mounting following pages a selection of oue standard circuits. The CI-K... insulated enclosures are silicon and halogen
accessories free.
CI-K1-T0
T0(3).../E EZ-T0 V/EA/SVB-T0 T0(3).../XZ IVS-T0 CI-K2-T3 DE-T0
V/EA/SVB-T0
T0-1-(T3-1-).../EA/SVB
T0(3).../EZ
. T0.../IVS1) T0-.../I1 T0(3).../Z1)
.
. T3-.../I2
T0-4-(T3-6-).../EA/SVB
T0-1-(T3-1-).../V/SVB
.
.
.
T0-4-(T3-6-).../V/SVB
V/EA/SVB-T5 SVB-P3
T5(B).../Z
T5(B).../EA/SVB T5B-.../I4
T5-.../I5
T5B-.../I4/SVB
T5(B).../V/SVB T5-.../I5/SVB
P. . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . .
Switch sizes Rated uninterrupted current Mounting form Part no. suffix Accessories
P1 or P3 a Page 7/2 (if required) from a Page 7/47
Add-on functions due to modular system
3-pole basic unit Switched neutral Auxiliary contact Terminal shroud N + PE terminals,
.../E or .../Z Can be fitted left Can be fitted left can be fitted at also as cover interlock
or right or right top or bottom on .../Z-switches.
(for P1.../I: left only) (for P1.../I: left only)
TM-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .
Circuit representation
(see also ordering example in the electronic
Front plate inscription
START catalogue)
2
0
1
START
Bridge
1
2
3
4
5
6
7
8
Connection designation
Contact Main con- Auxiliary Max. motor Rated Design Protection type Part no. Price Std. pack
sequence ducting contacts rating uninterrupted Article no. see price
Front plate paths current list
no.
No. of AC-23A
poles 400/415 V
ON
50-60 Hz
OFF
N/O N/O N/ P Iu
FS 908 C kW A
Main switches, maintenance switches
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device
1 0 0 6.5 20 Surface mounting IP65 T0-1-8200/I1/SVB 1 off
0 1
207145
1 0 0 6.5 20 Flush mounting Front IP65 T0-1-8200/EA/SVB
1
2
053110
1 0 0 6.5 20 Rear mounting Front IP65 T0-1-8200/V/SVB
057856
1 0 0 13 32 Surface mounting IP65 T3-1-8200/I2/SVB
207200
1 0 0 13 32 Flush mounting Front IP65 T3-1-8200/EA/SVB
066576
1 0 0 22 63 Surface mounting IP65 T5B-1-8200/I4/SVB
207240
1 0 0 22 63 Flush mounting Front IP65 T5B-1-8200/EA/SVB
094279
2 0 0 6.5 20 Surface mounting IP65 T0-1-102/I1/SVB
0 1
207143
1
2
3
4
207147
1
2
3
4
5
6
280898
3 0 0 45 125 Rear mounting Front IP65 P5-125/V/SVB
1
2
3
4
5
6
280914
3 0 0 50 100 Surface mounting IP65 P3-100/I5/SVB
207373
3 0 0 50 100 Flush mounting Front IP65 P3-100/EA/SVB
074320
3 0 0 50 100 Rear mounting Front IP65 P3-100/V/SVB
088558
3 0 0 55 160 Flush mounting Front IP65 P5-160/EA/SVB
280922
3 0 0 55 160 Rear mounting Front IP65 P5-160/V/SVB
280928
3 0 0 90 250 Flush mounting Front IP65 P5-250/EA/SVB
280936
3 0 0 90 250 Rear mounting Front IP65 P5-250/V/SVB
280942
3 0 0 110 315 Flush mounting Front IP65 P5-315/EA/SVB
280950
3 0 0 110 315 Rear mounting Front IP65 P5-315/V/SVB
280956
3+N 0 0 6.5 20 Surface mounting IP65 T0-2-8900/I1/SVB
0 1
207151
1
2
3
4
5
6
7
8
227860
3+N 0 0 13 25 Surface mounting P1-25/I2/SVB/N
1
2
3
4
5
6
N
N
207298
3+N 0 0 13 25 Flush mounting Front IP65 P1-25/EA/SVB/N
081587
3+N 0 0 13 25 Rear mounting Front IP65 P1-25/V/SVB/N
086333
3+N 0 0 15 32 Surface mounting IP65 P1-32/I2/SVB/N
207319
3+N 0 0 15 32 Surface mounting P1-32/I2H/SVB/N1)
227871
3+N 0 0 15 32 Flush mounting Front IP65 P1-32/EA/SVB/N
091079
3+N 0 0 15 32 Rear mounting Front IP65 P1-32/V/SVB/N
095825
3+N 0 0 37 63 Surface mounting IP65 P3-63/I4/SVB/N
207349
3+N 0 0 37 63 Flush mounting Front IP65 P3-63/EA/SVB/N
010398
3+N 0 0 37 63 Rear mounting Front IP65 P3-63/V/SVB/N
015144
3+N 0 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB/N
280910
3+N 0 0 45 125 Rear mounting Front IP65 P5-125/V/SVB/N
280916
3+N 0 0 50 100 Surface mounting IP65 P3-100/I5/SVB/N
207379
3+N 0 0 50 100 Flush mounting Front IP65 P3-100/EA/SVB/N
019890
3+N 0 0 50 100 Rear mounting Front IP65 P3-100/V/SVB/N
024636
Notes 1) Enclosures with hard metric knock-outs
7/12 Ordering
Load current switches, main switches, maintenance/repair switches
T, P Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Contact sequence Main Auxiliary Max. Rated Design Protection Part no. Price Std. pack
Front plate no. conduct- contacts motor uninter- type Article no. see price
ing rating rupted list
ON
paths current
OFF
No. of AC-23A
FS 908
poles 400/415 V
50-60 Hz
N/O N/ N P Iu
O /
C
kW A
Main switches, maintenance switches
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position
As Emergency-Stop device
3+N 0 0 55 160 Flush mounting Front IP65 P5-160/EA/SVB/N 1 off
0 1
280924
3+N 0 0 55 160 Rear mounting Front IP65 P5-160/V/SVB/N
1
2
3
4
5
6
N
N
280930
3+N 0 0 90 250 Flush mounting Front IP65 P5-250/EA/SVB/N
280938
3+N 0 0 90 250 Rear mounting Front IP65 P5-250/V/SVB/N
280944
3+N 0 0 110 315 Flush mounting Front IP65 P5-315/EA/SVB/N
280952
3+N 0 0 110 315 Rear mounting Front IP65 P5-315/V/SVB/N
280958
6 0 0 6.5 20 Surface mounting IP65 T0-3-8342/I1/SVB
0 1
207159
1
2
3
4
5
6
7
8
9
10
11
12
207163
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
mounting 207149
1
2
3
4
5
6
7
8
280899
1
2
3
4
5
6
13
14
mounting 207297
1
2
3
4
5
6
13
14
21
22
Contact sequence Main con- Auxiliary Max. motor Rated unin- Design Protection Part no. Price Std.
Front plate no. ducting contacts rating terrupted type Article no. see pack
ON
paths current price
OFF list
FS 908 No. of AC-23A
poles 400/415 V
50-60 Hz
N/O N/ N/C P Iu
O kW A
207157
1
2
3
4
5
6
7
8
9
10
11
12
207153
1
2
3
4
5
6
7
8
9
10
11
12
048367
1
2
3
4
5
6
N
N
13
14
21
22
231934
1
2
3
4
5
6
7
8
9
10
11
12
207161
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
207281
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
207146
1
2
207144
1
2
3
4
207148
1
2
3
4
5
6
Contact Main Auxiliary Max. motor Rated Design Protection Part no. Price Std. pack
sequence conducting contacts rating uninterrupted type Article no. see price
Front plate no. paths current list
ON
No. of poles AC-23A
OFF
400/415 V
FS 908 50-60 Hz
N/O N/O N P Iu
/C kW A
Main switches, maintenance switches
With black rotary handle and locking collar, lockable in the 0 position
Without Emergency-Stop function
mounting 207315
1
2
3
4
5
6
mounting 207152
1
2
3
4
5
6
7
8
mounting 207296
1
2
3
4
5
6
N
N
207376
1
2
3
4
5
6
N
N
207160
1
2
3
4
5
6
7
8
9
10
11
12
207164
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Contact sequence Main Auxiliary Max. motor Rated Design Protection Part no. Price Std. pack
Front plate no. conduct- contacts rating uninter- type Article no. see price
ing rupted list
ON
paths current
OFF
AC-23A
FS 908 No. of 400/415 V
poles 50-60 Hz
N/O N/ N P Iu
O /
C kW A
Main switches, maintenance switches
With black rotary handle and locking collar, lockable in the 0 position
Without Emergency-Stop function
3 1 0 6.5 20 Surface mounting IP65 T0-2-15679/I1/SVB-SW 1 off
0 1
207150
1
2
3
4
5
6
7
8
207295
1
2
3
4
5
6
13
14
21
22
207158
1
2
3
4
5
6
7
8
9
10
11
12
207154
1
2
3
4
5
6
7
8
9
10
11
12
050740
3+N 1 1 15 32 Flush mounting Front IP65 P1-32/EA/SVB-SW/N/HI11
1
2
3
4
5
6
7
8
9
10
11
12
060232
3+N 1 1 15 32 Rear mounting Front IP65 P1-32/V/SVB-SW/N/HI11
064978
3+N 1 1 37 63 Surface mounting IP65 P3-63/I4/SVB-SW/N/HI11
207347
3+N 1 1 37 63 Flush mounting Front IP65 P3-63/EA/SVB-SW/N/HI11
069724
3+N 1 1 37 63 Rear mounting Front IP65 P3-63/V/SVB-SW/N/HI11
074470
3+N 1 1 50 100 Surface mounting IP65 P3-100/I5/SVB-SW/N/HI11
207377
3+N 1 1 50 100 Flush mounting Front IP65 P3-100/EA/SVB-SW/N/HI11
079216
3+N 1 1 50 100 Rear mounting Front IP65 P3-100/V/SVB-SW/N/HI11
083962
3+N 1 1 6.5 20 Flush mounting Front IP65 T0-3-8901/EA/SVB-SW
0 1
231933
3+N 1 1 13 32 Surface mounting IP65 T3-3-8901/I2/SVB-SW
1
2
3
4
5
6
7
8
9
10
11
12
218988
3+N 1 1 22 63 Surface mounting IP65 T5B-3-8901/I4/SVB-SW
207245
3+N 1 1 22 63 Flush mounting Front IP65 T5B-3-8901/EA/SVB-SW
207421
3+N 1 1 30 100 Surface mounting IP65 T5-3-8901/I5/SVB-SW
207278
6 1 1 6.5 20 Surface mounting IP65 T0-4-15682/I1/SVB-SW
0 1
207162
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Contact Main Auxiliary Max. motor Rated Design Protection Part no. Price Std. pack
sequence conducting contacts rating uninter- type Article no. see price
Front plate no. paths rupted list
current
ON
No. of poles AC-23A Iu
OFF
FS 908
400/415 V A
50-60 Hz
N/O N/O N/C P
kW
On-Off switches
As Emergency-Stop device
According to IEC/EN60204-1, VDE 113 Part 1
with red thumb grip and yellow front plate
1 0 0 6.5 20 Flush Front IP65 T0-1-8200/E-RT 1 off
0 1
mounting 009474
1
2
mounting 207062
1
2
3
4
mounting 207082
1
2
3
4
5
6
mounting 207399
1
2
3
4
5
6
7
8
Ordering 7/21
Load current switches, ON/OFF switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T, P
207074
1
2
207061
2 0 0 6.5 20 Flush mounting Front IP65 T0-1-102/E
1
2
3
4
088709
2 0 0 6.5 20 Distribution board Front IP30 T0-1-102/IVS
mounting 015147
207081
1
2
3
4
5
6
Contact Main Auxiliary Max. motor Rated Design Protection Part no. Std. pack
sequence conducting contacts rating uninterrupted type Article no.
Front plate no. paths current
ON
No. of poles AC-23A
OFF
FS 908 400/415 V
N/O N/ N 50-60 Hz
O / P Iu
C
kW A
On-Off switches
with black thumb grip and front plate
Without auxiliary contacts
3 0 0 15 32 Surface mounting IP65 P1-32/I2 1off
0 1
207320
1
2
3
4
5
6
207109
1
2
3
4
5
6
7
8
400/415 V
N/O N/O N/C 50-60 Hz
P Iu
kW A
On-Off switches
with black thumb grip and front plate
Without auxiliary contacts
3+N 0 0 13 25 Surface mounting IP65 P1-25/I2/N 1off
0 1
207303
1
2
3
4
5
6
N
N
207131
1
2
3
4
5
6
7
8
9
10
11
12
Contact sequence Main con- Auxiliary Max. motor Rated Design Protection Part no. Price Std.
Front plate no. ducting contacts rating uninter- type Article no. see price pack
paths rupted list
ON
current
OFF
No. of AC-23A
FS 908 poles
400/415 V
50-60 Hz
N/O N/O N/C P Iu
kW A
On-Off switches
with black thumb grip and front plate
Without auxiliary contacts
8 0 0 6.5 20 Surface mounting IP65 T0-4-8344/I1 1 off
0 1
207139
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
207094
1
2
3
4
5
6
7
8
231941
1
2
3
4
5
6
7
8
9
10
11
12
226899
1
2
3
4
5
6
13
14
21
22
207118
1
2
3
4
5
6
7
8
9
10
11
12
207135
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
kW A
Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
Group switches, mains transfer switches
1 6.5 20 Surface mounting IP65 T0-1-8210/I1 1 off
2 0 1
0
1 2
207076
FS 684 1 6.5 20 Flush mounting Front IP65 T0-1-8210/E
1
2
3
4
012742
1 6.5 20 Distribution board Front IP30 T0-1-8210/IVS
mounting 074440
0
1 2
207102
FS 684
2 6.5 20 Flush mounting Front IP65 T0-2-8211/E
022234
1
2
3
4
5
6
7
8
0
1 2
207123
FS 684 3 6.5 20 Flush mounting Front IP65 T0-3-8212/E
1
2
3
4
5
6
7
8
9
10
11
12
029353
3 6.5 20 Distribution board Front IP30 T0-3-8212/IVS
mounting 079186
Contact sequence Front Main Max. motor Rated Design Protection Part no. Price Std. pack
plate con- rating uninter- type Article no. see price
no. ducting rupted list
paths current
No. of AC-23A
poles
400/415 V
50-60 Hz
N/O P Iu
kW A
Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
Group switches, mains transfer switches
3 13 32 Surface mounting IP65 T3-3-8212/I2 1 off
2 0 1
0
1 2
207183
FS 684 3 13 32 Flush mounting Front IP65 T3-3-8212/E
1
2
3
4
5
6
7
8
9
10
11
12
068956
3 13 32 Centre mounting Front IP65 T3-3-8212/EZ
003080
1 2
214781
3 132 315 Flush mounting Front IP65 T8-3-8212/E/HI12
214782
1
2
3
4
5
6
7
8
9
10
11
12
101
102
103
104
105
106
0
1 2
207136
FS 684 4 6.5 20 Flush mounting Front IP65 T0-4-8213/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
031726
4 6.5 20 Distribution board Front IP30 T0-4-8213/IVS
mounting 081559
4 6.5 20 Centre mounting Front IP65 T0-4-8213/EZ
062575
kW A
Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
Group switches, mains transfer switches
4 6.5 20 Surface mounting IP65 T0-4-8294/I1 1 off
1 0 2
0
1 2 207138
FS 953 4 6.5 20 Flush mounting Front IP65 T0-4-8294/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
010371
4 6.5 20 Distribution board Front IP30 T0-4-8294/IVS
mounting 043594
Mains
NETZ
0 NOT-
STROM
4 13 32 Flush mounting Front IP65 T3-4-8902/E
0
Stand-by
215222
FS 161629 4 13 32 Flush mounting Front IP65 T3-4-8902/EZ
215223
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Contact sequence Front Main con- Max. motor rating Rated Design Protection Part no. Price Std. pack
plate ducting uninter- type Article no. see price
no. paths rupted list
No. of AC-23A current
poles
400/415 V
50-60 Hz
N/O P Iu
kW A
Changeover switches
With black thumb-grip and grey front plate
With 0 (Off) position
With spring-return from both directions to 0
1 6.5 20 Surface mounting IP65 T0-1-8214/I1 1 off
2
0
1 2
207077
0
1
019863
1 6.5 20 Distribution board Front IP30 T0-1-8214/IVS
mounting 045967
1 6.5 20 Centre mounting Front IP65 T0-1-8214/EZ
076815
1 6.5 20 Rear mounting Front IP65 T0-1-8214/Z
050720
2 6.5 20 Surface mounting IP65 T0-2-8215/I1
2
207103
0
1
022236
2 6.5 20 Distribution board Front IP30 T0-2-8215/IVS
mounting 048340
2 6.5 20 Centre mounting Front IP65 T0-2-8215/EZ
081561
3 6.5 20 Surface mounting IP65 T0-3-8216/I1
2
207434
0
1
024609
3 6.5 20 Centre mounting Front IP65 T0-3-8216/EZ
086307
3 13 32 Surface mounting IP65 T3-3-8216/I2
207184
3 13 32 Flush mounting Front IP65 T3-3-8216/E
023870
Without 0 (Off) position
Changeover switches
1 6.5 20 Surface mounting IP65 T0-1-8220/I1 1 off
1 2
1 2
207078
1 6.5 20 Flush mounting Front IP65 T0-1-8220/E
1
2
3
4
FS 943
031728
1 6.5 20 Distribution board Front IP30 T0-1-8220/IVS
mounting 055459
1 6.5 20 Centre mounting Front IP65 T0-1-8220/EZ
095799
1 6.5 20 Rear mounting Front IP65 T0-1-8220/Z
086312
2 6.5 20 Surface mounting IP65 T0-2-8221/I1
1 2
207104
2 6.5 20 Flush mounting Front IP65 T0-2-8221/E
1
2
3
4
5
6
7
8
038847
2 6.5 20 Distribution board Front IP30 T0-2-8221/IVS
mounting 057832
2 6.5 20 Centre mounting Front IP65 T0-2-8221/EZ
010372
2 22 32 Surface mounting IP65 T3-2-8221/I2
207180
2 22 32 Flush mounting Front IP65 T3-2-8221/E
045227
2 22 63 Surface mounting IP65 T5B-2-8221/I4
207221
2 22 63 Flush mounting Front IP65 T5B-2-8221/E
093047
Ordering 7/29
Load current switches, changeover switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3, T5(B), T6, T8
207124
3 6.5 20 Flush mounting Front IP65 T0-3-8222/E
1
2
3
4
5
6
7
8
9
10
11
12
048339
3 6.5 20 Distribution board Front IP30 T0-3-8222/IVS
mounting 060205
3 6.5 20 Centre mounting Front IP65 T0-3-8222/EZ
015118
3 13 32 Flush mounting Front IP65 T3-3-8222/E
1 2
052346
3 22 32 Surface mounting IP65 T3-3-8222/I2
1
2
3
4
5
6
7
8
9
10
11
12
207185
3 22 63 Surface mounting IP65 T5B-3-8222/I4
207224
3 22 63 Flush mounting Front IP65 T5B-3-8222/E
092378
3 22 63 Rear mounting Front IP65 T5B-3-8222/Z
092375
4 6.5 20 Surface mounting IP65 T0-4-8223/I1
1 2
207137
4 6.5 20 Flush mounting Front IP65 T0-4-8223/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
050712
4 6.5 20 Distribution board Front IP30 T0-4-8223/IVS
mounting 062578
4 6.5 20 Centre mounting Front IP65 T0-4-8223/EZ
019864
4 6.5 20 Rear mounting Front IP65 T0-4-8223/Z
086315
4 13 32 Surface mounting IP65 T3-4-8223/I2
207192
4 13 32 Flush mounting Front IP65 T3-4-8223/E
059465
4 13 32 Rear mounting Front IP65 T3-4-8223/Z
061838
4 22 63 Surface mounting IP65 T5B-4-8223/I4
207231
4 22 63 Flush mounting Front IP65 T5B-4-8223/E
092108
4 22 63 Rear mounting Front IP65 T5B-4-8223/Z
092105
5 6.5 20 Flush mounting Front IP65 T0-5-8369/E
1 2
060204
5 22 32 Surface mounting IP65 T3-5-8369/I2
207536
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
062577
6 6.5 20 Distribution board Front IP30 T0-6-8370/IVS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
mounting 067324
6 6.5 20 Centre mounting Front IP65 T0-6-8370/EZ
029356
6 22 32 Flush mounting Front IP65 T3-6-8370/E
073703
8 6.5 20 Flush mounting Front IP65 T0-8-8372/E
1 2
064950
8 6.5 20 Distribution board Front IP30 T0-8-8372/IVS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
mounting 069697
8 22 32 Flush mounting Front IP65 T3-8-8372/E
080822
7/30 Ordering
Load-current switch - Safety switch
P1, P3, T5(B) Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Contact sequence Main Auxiliary contacts Max. motor rating Rated Design Part no. Price Std. pack
con- uninter- Article no. see price
ducting rupted list
paths current
Front plate no. No. of AC-23A
poles
ON
400/415 V
OFF
50-60 Hz
FS 908 N/O N/O N/C P Iu
kW A
mounting 207308
IP65
1
2
3
4
5
6
3 0 0 15 32 P1-32/I2-SI 1 off
207329
3 0 0 37 63 P3-63/I4-SI 1 off
207361
3 0 0 50 100 P3-100/I5-SI 1 off
207386
3+N 0 0 13 25 P1-25/I2-SI/N 1 off
0 1
207312
1
2
3
4
5
6
N
N
207310
1
2
3
4
5
6
13
14
21
22
3 1 1 15 32 P1-32/I2-SI/HI11 1 off
207331
3 1 1 37 63 P3-63/I4-SI/HI11 1 off
207363
3 1 1 50 100 P3-100/I5-SI/HI11 1 off
207388
6 0 0 22 63 T5B-3-8342/I4-SI 1 off
0 1
207250
1
2
3
4
5
6
7
8
9
10
11
12
207254
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
207258
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
mounting 207309
IP65
1
2
3
4
5
6
3 0 0 15 32 P1-32/I2-SI-SW 1 off
207330
3 0 0 37 63 P3-63/I4-SI-SW 1 off
207362
kW A
Without Emergency-Stop
function
3+N 0 0 13 25 Surface P1-25/I2-SI/N-SW 1 off
0 1
mounting 207313
IP65
1
2
3
4
5
6
N
N
207311
1
2
3
4
5
6
13
14
21
22
3 1 1 15 32 P1-32/I2-SI/HI11-SW 1 off
207332
3 1 1 37 63 P3-63/I4-SI/HI11-SW 1 off
207364
3 1 1 50 100 P3-100/I5-SI/HI11-SW 1 off
207389
6 0 0 22 63 T5B-3-8342/I4-SI-SW 1 off
0 1
207251
1
2
3
4
5
6
7
8
9
10
11
12
6 1 1 22 63 T5B-4-15682/I4-SI-SW 1 off
0 1
207255
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Engineering 4) The "ON" position can be locked using a padlock (after altering the handle) This
Maintenance, repair and safety switches all have the same electrical function. They is not permissable for switches with red/yellow handles.
are designed to safely isolate electrical installations (loads) from mains power
during maintenance and repair work and to ensure that a hazard does not arise Example:
which endangers personnel, machinery and production materials. Safety switch with load shedding and annunciation
Safety switches are main switches with an additional enclosure. Installed in the L1
immediate vicinity of the motor or the electrical load they act as switch- L2
L3
disconnectors for that load. It makes possible work without danger according to DIN N
EN 50110/VDE 0105. This is particularly important if there is any danger of the main
switch being inadvertently operated. FAZ-
F1 F0 B4/1-HS
Application
1 3 5 95
By securing the switch in the OFF position with his own padlock (up to 3 can be
Q11 F2
fitted), the fitter/electrician can protect himself against the possibility of any other 96
2 4 6
person switching the machine on. Maintenance switches are merely additional, 21
enclosed main switches with a padlocking facility. F2 O
Enclosed main switch with padlock interlock 22
a 7/10
13 13
a 7/30
I Q11
14 14
Features
Safety switches are housed in insulated enclosures and bear the inscription
Safety switch on a bright orange label. 1 3 5 7 9 11
With special red handle and yellow locking ring for Emergency_Stop use Q1
according to STOP category O IEC/EN 60204/VDE 0113. 2 4 6 8 10 12
If the switch is not usable for Emergency_Stop both parts are black (partno. suffix U V W
"SW")
The cover and handle can be interlocked by fitting a padlock. A1
P1 P2 Q11
M A2
Selection 3
Switches must be selected according to the following criteria:
1) according to motor switching capacity, when the switch is fitted in so that the
operator may use it for operational ON and OFF switching.
2) The rating data always applies for 3 poles. When the motor rating is divided
between 6 poles, such as for star-delta starting, a 6-pole switch can be used to
control 1.73 times the rated power.
3) If the switch has a load-shedding contact (LA), you can select the appropriate
switch according to the uninterrupted current. The load-shedding contact is an
auxiliary contact, which is closed in the ON position and opens early when switching
off, so that a contactor located in the circuit takes over the switching capacity and
the maintenance/safety switch operates at zero load. When switching on, the load-
shedding contact closes later than or at the same time as the main contacts. With P
and T switches this is the N/O auxiliary contact.
7/32 Ordering
Load current switch - reversing switch
T0, T3, T5B Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Contact sequence Front Main Max. motor Rated Design Protection Part no. Price Std. pack
plate conducting rating uninterrupted type Article no. see price
no. paths current list
No. of AC-23A
poles
N/O 400/415 V
50-60 Hz
P Iu
kW A
1 2
207111
FS 684
Flush mounting Front IP65 T0-2-8400/E
053079
1
2
3
4
5
6
7
8
1 2
207132
FS 684
Flush mounting Front IP65 T0-3-8401/E
091047
1
2
3
4
5
6
7
8
9
10
0
1 2
207125
0
1
FS 4011
Flush mounting Front IP65 T0-3-8228/E
015112
1
2
3
4
5
6
7
8
9
10
Y
0
mounting 207140
FS 635 Flush mounting Front IP65 T0-4-8410/E
024604
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0
Y Y
000893
FS 638 22 32 Surface IP65 T3-5-15876/I2
mounting 207537
Flush mounting Front IP65 T3-5-15876/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
016776
Rear mounting Front IP65 T3-5-15876/Z
019149
0
Y Y
214785
FS 4017
Flush mounting Front IP65 T5B-5-15876/Z
214786
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1 1
2 2 055460
Centre Front IP65 T0-6-15866/EZ
FS 629
mounting 012747
1 1
2 2
214788
FS 441
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
7/34 Ordering
Control switch, multi-speed switch
T0, T3, T5B Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Contact sequence Front Main con- Max. motor Rated Design Protec- Part no. Price Std.
plate ducting rating uninterrupted tion type Article no. see price pack
no. paths current list
No. of AC-23A
poles
400/415 V
50-60 Hz
N/O P Iu
kW A
Multi-speed switches
with black thumb grip and front plate
Two-speed, non reversing, for 2 separate windings
1 3 6.5 20 Surface mounting IP65 T0-3-8451/I1 1 off
0 1 2
0 2
207133
FS 644
Flush mounting Front IP65 T0-3-8451/E
038849
1
2
3
4
5
6
7
8
9
10
11
12
0 2
207141
FS 644
Flush mounting Front IP65 T0-4-8440/E
041222
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 2
207142
FS 684
Flush mounting Front IP65 T0-4-8441/E
043595
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Step switches
With black thumb-grip and grey front plate
One contact closed per step
(without overlap)
With 0 (Off) position
2 1 Surface mounting IP 65 T0-1-8240/I1
0 1 2
1
0 207079
FS 418 Flush mounting Front IP 65 T0-1-8240/E
034105
1
2
3
4
2
1 3
0 207107
FS 420 Flush mounting Front IP 65 T0-2-8241/E
050716
1
2
3
4
5
6
1 3
0 4 207108
FS 422 Flush mounting Front IP 65 T0-2-8242/E
067327
1
2
3
4
5
6
7
8
1 3
0
5
4
207128
FS 424 Flush mounting Front IP 65 T0-3-8243/E
081565
Distribution board Front IP 30 T0-3-8243/IVS
1
2
3
4
5
6
7
8
9
10
mounting 088684
Centre mounting Front IP 65 T0-3-8243/EZ
083938
2 1 Flush mounting Front IP 65 T0-3-8244/E
0 1 2 3 4 5 6
1 3
0
5
4 095803
6
Distribution board Front IP 30 T0-3-8244/IVS
FS 426
mounting 012749
Centre mounting Front IP 65 T0-3-8244/EZ
098176
1
2
3
4
5
6
7
8
9
10
11
12
1
0 207130
FS 418 Flush mounting Front IP 65 T0-3-8280/E
1
2
3
4
5
6
7
8
9
10
11
12
034106
Centre mounting Front IP 65 T0-3-8280/EZ
036479
2 3 Flush mounting Front IP 65 T0-5-8281/E
0 1 2 3
1 3
0 048344
FS 420
Distribution board Front IP 30 T0-5-8281/IVS
mounting 055463
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1 3
0 4
062582
FS 422
Distribution board Front IP 30 T0-6-8282/IVS
mounting 069701
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Contact sequence Front plate no. No. of Design Protection type Part no. Price Std. pack
poles Article no. see price list
Step switches
With black thumb-grip and grey front plate
One contact closed per step
(without overlap)
Without 0 (Off) position
1 Surface mounting IP65 T0-1-8220/I1 1 off
1 2
1 2
207078
1 Flush mounting Front IP65 T0-1-8220/E 1 off
1
2
3
4
FS 943
031728
1 Distribution board Front IP30 T0-1-8220/IVS 1 off
mounting 055459
1 Centre mounting Front IP65 T0-1-8220/EZ 1 off
095799
1 Rear mounting Front IP65 T0-1-8220/Z 1 off
086312
3 1 Surface mounting IP 65 T0-2-8230/I1 1 off
1 2 3
2
1
207105
FS 404 1 Flush mounting Front IP 65 T0-2-8230/E 1 off
1
2
3
4
5
6
088685
1 Distribution board Front IP 30 T0-2-8230/IVS 1 off
mounting 095804
1 Centre mounting Front IP 65 T0-2-8230/EZ 1 off
091058
2 3 1 Surface mounting IP 65 T0-2-8231/I1 1 off
1 2 3 4
1 4
207106
FS 606 1 Flush mounting Front IP 65 T0-2-8231/E 1 off
012750
1
2
3
4
5
6
7
8
2 4
1 5 026988
FS 408
1 Distribution board Front IP 30 T0-3-8232/IVS 1 off
mounting 034107
1 Centre mounting Front IP 65 T0-3-8232/EZ 1 off
1
2
3
4
5
6
7
8
9-
10
029361
3 1 Surface mounting IP 65 T0-3-8233/I1 1 off
1 2 3 4 5 6
2 4
1
6
5
207127
FS 410 1 Flush mounting Front IP 65 T0-3-8233/E 1 off
041226
1 Distribution board Front IP 30 T0-3-8233/IVS 1 off
1
2
3
4
5
6
7
8
9
10
11
12
mounting 048345
1 Centre mounting Front IP 65 T0-3-8233/EZ 1 off
043599
3 2 Flush mounting Front IP 65 T0-4-8251/E 1 off
1 2 3 4
2 4
1 013971
FS 406
2 Centre mounting Front IP 65 T0-4-8251/EZ 1 off
013972
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 2
207124
3 Flush mounting Front IP65 T0-3-8222/E 1 off
1
2
3
4
5
6
7
8
9
10
11
12
FS 943
048339
3 Distribution board Front IP30 T0-3-8222/IVS 1 off
mounting 060205
3 Centre mounting Front IP65 T0-3-8222/EZ 1 off
015118
3 3 Flush mounting Front IP 65 T0-5-8270/E 1 off
1 2 3
2
1
091059
FS 404 3 Distribution board Front IP 30 T0-5-8270/IVS 1 off
mounting 098178
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
2 4
1 015124
FS 406
3 Centre mounting Front IP 65 T0-6-8271/EZ 1 off
017497
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Ordering 7/37
Control switch, ON-OFF switches, changeover switches, Hand/Auto switches
http://catalog.moeller.net Moeller HPL0211-2003
On-Off switches
With black thumb-grip and grey front plate
One contact closed per step
(without overlap)
1 Flush mounting Front IP 65 T0-1-15401/E 1 off
0 1
0
1
038854
1
2
FS 415
1 Centre mounting Front IP 65 T0-1-15401/EZ 1 off
041227
1 Surface mounting IP 65 T0-1-15401/I1 1 off
207067
1 Distribution board Front IP30 T0-1-15401/IVS 1 off
mounting 045973
2 Flush mounting Front IP 65 T0-1-15402/E 1 off
0 1
053092
1
2
3
4
067330
1
2
3
4
5
6
081568
1
2
3
4
5
6
7
8
2 1
095806
FS 429
1 Centre mounting Front IP 65 T0-1-15421/EZ 1 off
098179
1
2
3
4
019871
2 Distribution board Front IP30 T0-2-15422/IVS 1 off
mounting 026990
1
2
3
4
5
6
7
8
207114
3 Flush mounting Front IP 65 T0-3-15423/E 1 off
1
2
3
4
5
6
7
8
9
10
11
12
034109
Hand/Auto switches
With 0 (Off) position
Without spring-return
AUTO 0
HAND AUTO
1 Surface mounting IP65 T0-1-15431/I1 1 off
0
HAND
207070
FS 1401 Flush mounting Front IP 65 T0-1-15431/E
1
2
3
4
019872
Distribution board IP65 T0-1-15431/IVS
mounting 026991
Centre mounting Front IP 65 T0-1-15431/EZ
022245
Rear mounting Front IP 65 T0-1-15431/Z
029364
7/38 Ordering
Control switch - hand/auto switch
T0 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price list
Hand/Auto switches
With 0 (Off) position
Without spring- AUTO 0
HAND AUTO
2 Surface mounting IP65 T0-2-15432/I1 1 off
0
return HAND
207091
FS 1401 Flush mounting Front IP 65 T0-2-15432/E
1
2
3
4
5
6
7
8
034110
Distribution board IP65 T0-2-15432/IVS
mounting 041229
Centre mounting Front IP 65 T0-2-15432/EZ
036483
Rear mounting Front IP 65 T0-2-15432/Z
043602
AUTO 0
HAND AUTO
3 Surface mounting IP65 T0-3-15433/I1 1 off
0
HAND
207115
FS 1401 Flush mounting Front IP 65 T0-3-15433/E
1
2
3
4
5
6
7
8
9
10
11
12
048348
Distribution board IP65 T0-3-15433/IVS
mounting 055467
Centre mounting Front IP 65 T0-3-15433/EZ
050721
Rear mounting Front IP 65 T0-3-15433/Z
057840
With spring-return AUTO 0
HAND AUTO
1 Surface mounting IP65 T0-1-15434/I1 1 off
0
from HAND HAND
207071
FS 1414000 Flush mounting Front IP 65 T0-1-15434/E
1
2
3
4
062586
Centre mounting Front IP 65 T0-1-15434/EZ
018053
AUTO 0
HAND AUTO
2 Layout IP65 T0-2-15435/I1 1 off
0
HAND
218971
FS 1414000 Flush mounting Front IP 65 T0-2-15435/E
1
2
3
4
5
6
7
8
003191
With spring-return START
0
1 Surface mounting IP65 T0-2-15907/I1 1 off
HAND
from START 0
AUTO HAND
START
207095
AUTO
FS 1413890
Flush mounting Front IP65 T0-2-15907/E
1
2
3
4
5
6
7
8
066931
Centre mounting Front IP65 T0-2-15907/EZ
069304
Rear mounting Front IP65 T0-2-15907/Z
078796
Without 0 (Off) position
Without spring- AUTO HAND AUTO 1 Surface mounting IP65 T0-1-15451/I1 1 off
HAND
return 207072
FS 19334 Flush mounting Front IP65 T0-1-15451/E
1
2
3
4
076824
Distribution board Front IP30 T0-1-15451/IVS
mounting 083943
Centre mounting Front IP65 T0-1-15451/EZ
079197
Rear mounting Front IP65 T0-1-15451/Z
086316
AUTO HAND AUTO 2 Flush mounting Front IP65 T0-2-15452/E 1 off
HAND
091062
FS 19334 Distribution board Front IP30 T0-2-15452/IVS
1
2
3
4
5
6
7
8
mounting 098181
Centre mounting Front IP65 T0-2-15452/EZ
093435
AUTO HAND AUTO 3 Flush mounting Front IP65 T0-3-15453/E 1 off
HAND
015127
FS 19334 Distribution board Front IP30 T0-3-15453/IVS
1
2
3
4
5
6
7
8
9
10
11
12
mounting 022246
Centre mounting Front IP65 T0-3-15453/EZ
017500
Rear mounting Front IP65 T0-3-15453/Z
024619
Ordering 7/39
Control switch - ON switches, universal control switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0
On switches
with black thumb grip and front plate
ON spring-return switches (make contact)
Spring-return in position 1
1 Flush mounting Front IP65 T0-1-15321/E 1 off
I 1
1
086317
1
2
FS 4721
Centre mounting Front IP65 T0-1-15321/EZ
088690
2 Flush mounting Front IP65 T0-1-15322/E
I 1
010382
1
2
3
4
207087
1
2
3
4
5
6
0 1
081572
I
0
FS 456
Centre mounting Front IP65 T0-1-15366/EZ
083945
1
2
3
4
019875
Centre mounting Front IP65 T0-1-15511/EZ
022248
Rear mounting Front IP65 T0-1-15511/Z
029367
START 2 Surface mounting IP65 T0-2-15512/I1
1
0
207093
Flush mounting Front IP65 T0-2-15512/E
1
2
3
4
5
6
7
8
034113
Centre mounting Front IP65 T0-2-15512/EZ
036486
START
1
0
2
see K Flush mounting Front IP65 T0-2-8177/E
2
0
START START 115 015130
1
START FS 140660 Centre mounting Front IP65 T0-2-8177/EZ
017503
Rear mounting Front IP65 T0-2-8177/Z
024622
1
2
3
4
5
6
7
8
2 1
029365
Centre mounting Front IP65 T0-3-15391/EZ
1
2
3
4
5
6
7
8
9
10
11
12
FS 429
031738
Spring-return from positions 1 and 2
Flush mounting Front IP65 T0-3-15394/E
1
0
2 1
072079
0
2
FS 458
Distribution board mounting Front IP30 T0-3-15394/IVS
1
2
3
4
5
6
7
8
9
10
11
12
079198
Centre mounting Front IP65 T0-3-15394/EZ
074452
7/40 Ordering
Control switches, instrument selector switches
T0 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Contact sequence Front plate Pole Design Protection Part no. Price Std. pack
no. type Article no. see price
list
Coding switches
With black thumb-grip and grey front plate
With complete rotation in both directions
1
2 3 4
5
Dual BCD CODE Flush mounting Front IP65 T0-4-15602/E 1 off
0
7
6 029368
0 1 2 3 4 5 6 7 8 9
9 8
Centre mounting Front IP65 T0-4-15602/EZ
FS 312
031741
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Series switches
With black thumb-grip and grey front plate
With 0 (Off) position (heater switches)
1 2 1 Flush mounting Front IP65 T0-1-91/E
0 1 2
0
072082
FS 614
1
2
3
4
L3-N L1-L2
0 L1-N 3 x phase to phase + 3 x phase Flush mounting Front IP65 T0-3-8007/E 1 off
L2-N
L1-N
L2-L3
L3-L1
L2-N
L3-N
to N with 0 (Off) position 095813
0
L1-L2 FS 1410759
Distribution board Front IP30 T0-3-8007/IVS
L2-L3 mounting 012759
L3-L1
L3-N
L2-N L1-L2
L2-L3
L3-L1
3 x phase to phase + 3 x phase Flush mounting Front IP65 T0-3-15924/E 1 off
L1-N L3-N L1-N
to N Without 0 position with 019878
L3-L1
L2-N
complete rotation in both Distribution board Front IP30 T0-3-15924/IVS
L2-L3 FS 164721
L1-L2
directions mounting 026997
L3-L1
L2-L3
L1-L2 L3-L1
3 x phase to phase with 0 (Off) Flush mounting Front IP65 T0-2-15920/E 1 off
L2-L3
0
position 038861
L1-L2
FS 1410755
Distribution board Front IP30 T0-2-15920/IVS
0 mounting 029452
L3-L1
L2-L3
L1-L2 L3-L1
3 x phase to phase without 0 Flush mounting Front IP65 T0-2-15922/E 1 off
L2-L3
(Off) position 053099
L1-L2 FS 164854 Centre mounting Front IP65 T0-2-15922/EZ
055472
1
2
3
4
5
6
7
8
FS 9440
Distribution board Front IP30 T0-3-8048/IVS
mounting 041235
036489
Ordering 7/41
Switches with locking mechanism
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, P1
P Iu
kW A
Panic switch
Cylinder lock SVA
Key withdrawable in position 0 and 1
If the key is withdrawn in position 1 the switch can be switched off but not on again without the key.
0 207085
1
2
3
4
5
6
3 13 25 ON
Layout IP65 P1-25/I2/SVA(S)-RT 1 off
FS 908 GE OFF 207306
OFF 207084
1
2
3
4
5
6
FS 908 3 13 25 ON
Layout IP65 P1-25/I2/SVA(S) 1 off
OFF 207305
0 207086
1
2
3
4
5
6
FS 908 GE
Notes
E
D F
C G
B 330
0
30 H
300 60
315 45
A 270 90 J
225 135
240 120
210 150
R 180 K
Q L
P M
N
Code letters for lockable switch positions
Letter S for panic lock with FS908GE
7/42 Ordering
Switches with locking mechanism
T0, P1 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Contact Front No. of Max. motor Rated Product Design Protection Part no. Price Std. pack
sequence plate no. poles rating uninterrupted view type Article no. see price
current list
AC-23A
400/415 V
50-60 Hz
P Iu
kW A
On-Off switch
with black thumb grip and front plate
Key can only be withdrawn in position 0 (Pos A)
Without Emergency-Stop function
Cylinder lock SVA
ON
2 6.5 20 Layout IP65 T0-1-102/I1/S 1 off
0 1
OFF 207063
1
2
3
4
FS 908
ON
2 6.5 20 Flush IP65 T0-1-102/EZ/S 1 off
0 1
FS 908
OFF 207083
1
2
3
4
5
6
FS 908 3 13 25 ON
Layout IP65 P1-25/I2/SVA(A) 1 off
OFF 207304
OFF
Notes
E
D F
C G
B 330
0
30 H
300 60
315 45
A 270 90 J
225 135
240 120
210 150
R 180 K
Q L
P M
N
Code letters for lockable switch positions
Letter S for panic lock with FS908GE
Ordering 7/43
Main switch assembly kits, thumb-grips, maintenance keys
http://catalog.moeller.net Moeller HPL0211-2007/2008 SVB-...-T0(P3), KNB-...-T0(P3)
With black rotary Without Emergency- T0-.../E, .../Z, .../I1 SVB-SW-T0 1 off for interlocking the 0 position
handle and black Stop function T3-.../E, .../Z, .../I2 060265 for interlocking the I position
locking ring P1-.../E, .../Z, .../I2 when required
T5B-.../E, .../Z, .../I4 SVB-SW-P3 1 off Lockable with max. 3
T5-.../E, .../Z, .../I5 062491 padlocks
P3-63/E, .../Z, .../I4
P3-100/E, .../Z, .../I5
Main switch assembly kits with PE terminal and N terminal
With red rotary as Emergency-Stop T0-.../E, .../Z V/EA/SVB-T0 1 off For conversion of T.../E flush
handle and yellow device according to T3-.../E, .../Z 062638 mounting switches with front
locking ring IEC/EN 60204-1, T5(B)-.../E, .../Z V/EA/SVB-T5 1 off plate FS908 into T.../EA/SVB...
VDE 0113 Part 1 045065 flush mounting main
switches.
For conversion of T.../Z rear
mounting switches (with front
With black rotary Without Emergency- T0-.../E, .../Z V/EA/SVB-SW-T0 1 off plate FS908) into interlocked
handle and black Stop function T3-.../E, .../Z 065011 T.../V/SVB rear mounting main
locking ring T5(B)-.../E, .../Z V/EA/SVB-SW-T5 1 off switches
045064
Thumb-grips
Black KNB-T0 10 off
038909
Red, only for KNB-RT-T0 10 off Order additional yellow front
Emergency-Stop 043655 plate FS908GE-T0
switch, according
to IEC/EN 60204-1,
VDE 0113 Part 1
ATEX style
According to 94/9EG
Test Certificate BVS04E106X
Only available together with basic device
with metric knock-outs M20 T0-.../I1 +ATEX-I1 1 off
237513
T3-.../I2 +ATEX-I2 1 off
P1-.../I2 237514
with solid side walls T5B-.../I4 +ATEX-I4 1 off
P3-.../I4 237516
T5-.../I5 +ATEX-I5 1 off
P3-.../I5 237517
7/44 Ordering
Front plates
FS-T0(P3) Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
mm
Notes
Standard front plates
For standard contact sequence the normal front plate can be replaced if required with the front plate shown here (not with T6, T8 and TM). This is provided the switching
angle, number of positions and the position of the 0 position are the same.
Switching angle 30
318 309 317 308 316 307 315 314 305 313 304 312 303 311 302 310 301
Switching angle 45
416 402 415 142003 147472 141883 455 141879 4721 4722 4723 496 41409 429 1401
AUS OFF AUS HALT HALT STOP 1 1 0 0 0 0 OFF
AUTO HAND HAND AUTO LANG- SCHNELL LINKS RECHTS ZU- VOR. FORW. REV. 0 2 2 1 1 2 1 HAND AUTO HAND AUTO
SAM 2
RUCK 0 START
1411 1420 1475 1404 1403 141538 147767 461 4026 462 4117 1414000 1413905
0 0 0 0 0 0 0 1 1 STOP 0 2 3 2 3 2
1 2 2 1 LINKS RECHTS 0 1 AUTO HAND 1 2 1 3 2 4 1 3
AUS EIN AUF ZU TRIP CLOSE AUS EIN STOP START FORW. REV.
START 0 1 0 1 0 4
RAISE LOWER
4011 458 1426 14988 147474 1413903 1446 456 1423 14510 141537 1413890 418 404 420 406 422
3 0 0 0 0 0 0 STOP 0 2 3 2 3 0 2
2 4 1 1 3 1 Y Y 1 1 2 1 1 2 FORW. REV. START START 1 3 2 4 1 3 2 4 1 1 1 3
1 5 2 2 4 2 2 2 START START 2 1 0 4 1 5 0 4 1 5 2 2 0 4
START START START START
5 6 5 3 3 7 5
6 7 6 6
408 441 453 4017 459 1409 140660 14712 142074 424 410 426 412 449 428
3 L2-N S-O L2-L3 S-T L1-L2 L1-N 0 OFF 0 OFF 0 OFF OFF 0
2 4 L1-L2 L1-N R-S R-O R-S START
L1-N L3-N R-O T-O L1-L2 L3-L1 R-S T-R 0 L2-L3 0 L2-N L1-L2 L1-N L1-L2 L1-L2 R-S
1 5 0 0 0 0 L1-N L3-L1 L1-L2 L3-N L2-L3 L2-N L2-L3 L2-N S-T S-O L2-L3 L2-L3 S-T S-T L3-L1 L1-L2 L3-N L1-N 1
8 6 L3-L1 L3-N L3-L1 L3-N T-R T-O L3-L1 L3-L1 T-R T-R
7 L2-L3 L2-N
414 1410757 14196 1410755 14195 1410756 1410758 1410759 147479 14944 1410763 140055 194321 194323 142010
Switching angle 60
0 1 HAND 1 SLOW Y START 0 0 0 NOT- 0 HALT HALT AUS AUS OFF OFF
1 2 AUTO 0 2 STOP FAST 0 STOP RUN 1 2 2 1 NETZ STROM LINKS RECHTS 2 1
AUF AB AUF AB HAND AUTO AUTO HAND HAND AUTO
611 601 1601 644 16052 635 16616 684 621 161629 161570 161359 161358 1610 1614 1673 1617
OFF OFF STOP STOP 2 L2-N L2-L3 1 2 0
AUTO MAN FORW. REV.
2 3 1 2 LOW MED. 2 3 Y
FORW. REV. SLOW FAST 1 3 L1-N L3-N L1-L2 L3-L1
0 1 0 3 OFF HIGH 1 4
1627 1628 1662 1665 655 164855 164854 614 604 616 160772 606 6034
START 0 0 0 STOP 0 STOP 1 2 1 2 2 3 0 0 L2-L3 S-T
1 2 3 3 1 1 1 SLOW SLOW Y Y START START 2 1 Y L1-L2 L3-L1 R-S T-R
0 0 3 0 3 1 4
1 4 4 2 2 2 FAST FAST RUN RUN 1 2 Y L3-N L1-N T-O R-O
4 5 4 6 5 0 0 L2-N S-O
164222 667 645 629 161002 638 161683 618 620 610 640 6010 164721 661
Switching angle 90
ON 1 2 EIN 1 0 0 1 AUS EIN STOP START HAND AUTO AUF ZU AUF AB UP DOWN SLOW FAST
1 2
0 1 AUS STOP 1
OFF HEIZUNG-
NOTSCHALTER
908 9508 902 190719 193935 907 945 1992 190334 943 19334 190550 19143 193975 190431
1 0 OFF 2 1 ON OFF 1 1 0 1 0 1 2 0 0 OFF AUTO
1 ON OFF 1 2 0 2 2 3 4 L2 S L2 AUS
910 953 192190 904 926 1957 192191 923 928 9441 193840 911 912 906 9440 935 19589 1922
Ordering 7/45
Add-on front plates
http://catalog.moeller.net Moeller HPL0211-2007/2008 ZFS
Blank, can be engraved None Rotary switches T0, T3, P1 ZFS60-T0 25 off
019924
Blank, can be engraved None Switch-disconnectors T5(B), P3 ZFS60-P3
022297
Engraved with standard text German/English Rotary switches T0, T3, P1 ZFS61/62-T0
030170
Engraved with standard text Spanish Switch-disconnectors T5(B), P3 ZFS77-P3
047422
Engraved with standard text French Switch-disconnectors T5(B), P3 ZFS63-P3
047423
Engraved with standard text French Rotary switches T0, T3, P1 ZFS63-T0
047424
Engraved with standard text German/English Switch-disconnectors T5(B), P3 ZFS61/62-P3
065739
Engraved with standard text Italian Rotary switches T0, T3, P1 ZFS68-T0
065751
Engraved with standard text Spanish Rotary switches T0, T3, P1 ZFS77-T0
065752
Engraved with standard text Hungarian Switch-disconnectors T5(B), P3 ZFS80-P3
205565
Engraved with standard text Portuguese Rotary switches T0, T3, P1 ZFS72-T0
205541
Engraved with standard text Swedish Rotary switches T0, T3, P1 ZFS75-T0
205544
Engraved with standard text Hungarian Rotary switches T0, T3, P1 ZFS80-T0
205548
Enter country reference when ordering:
D = German Switch-disconnector P5-.../EA/SVB ZFS(*)-P5 1 off
GB = English Switch-disconnector P5-.../V/SVB 105225
F = French
I = Italian
E = Spanish
Label mounts, black, plug-in type
Lock KMS1: Switch with FS908 are possible as main switch for T0-.../E, .../I1, .../Z up to max. 6 contact units Key withdrawal positions S(*)-T0 1 off
T0-1-... to T0-4-.../I1, .../E; T3-1-... to T3-4-.../I2; T3-1-... to T3- T3-.../E, .../Z up to max. 5 contact units are programmed ex-works 231959
6-.../E; P1-.../I2, .../E T3-.../I2 up to max. 4 contact units as ordered
SA(...) = Master key system (with master key) supplied with a P1-.../E, .../I2, .../Z S(*)-SOND-SA(*)-T0 1 off
security certificate. Order must include a lock plan showing 231965
the full configuration of the envisaged lock system. For
subsequent part orders, simply state the item number within
the lock plan, e.g. (A6294-1/2).
Neutral poles
Early-make, late-break
For side mounting, left or right P1-.../E, .../EA, .../EZ N-P1E 5 off
000651
With P1-.../I2: optional N-P1Z or HI11-P1/P3Z can only P1-.../Z, .../V, .../I2, .../IVS N-P1Z
be fitted to left 000652
P3-.../E, .../EA... N-P3E
062432
P3-.../Z, .../V, .../IVS N-P3Z
P3-63/E,.../Z, /I4 064805
P3-100/E, .../Z, .../I5
Neutral terminal
For side mounting P5-250(315)/Z(V) N-P5-250/315Z 1 off
280972
Protective conductor terminal
For side mounting P5-125(160)/E(EA) PE-P5-125/160E 1 off
280973
P5-250(315)/Z(V) PE-P5-250/315Z
280976
Auxiliary contacts
Late making N/O and early breaking N/C contacts. The N/O is always connected as a load-shedding contact.
For side mounting, left and/or right P1-.../E, .../EA..., .../EZ HI11-P1/P3E 5 off
P3-.../E, .../EA 061813
With P1-.../I2: HI11-P1/P3Z or N-P1Z can be fitted to left P1-.../Z, .../V, .../I2, .../IVS HI11-P1/P3Z
only P3-63/Z, .../V, .../I4, .../IVS 062031
P3-100/Z, .../V, .../I5, .../IVS
Centre mounting accessories
For single-hole fitting
Mounting diameter 22.3 mm
For rotary switches with existing front plate T0-.../E EZ-T0 1 off
T3-.../E 081622
Mounting diameter 22.3 mm and 30.5 mm T0-.../E EZ-P1 1 off
T3-.../E 091455
P1-.../E
Service distribution board mounting accessories
Includes push-fit shaft
For retrofitting T0-.../XZ basic switches as T0-.../IVS into T0-.../XZ IVS-T0 1 off
service distribution boards 091114
Ordering 7/49
Coupling drive, interlock parts, shaft extension
http://catalog.moeller.net Moeller HPL0211-2007/2008 DE-T0(P3), ZAV-T0(P3)
Coupling drive
Includes push-fit shaft
For retrofitting T0(T3)-.../XZ DE-T0 1 off
basic switches in the rear 093487
mounting form Spare parts
for T0(T3)/(P1)-.../Z
Interlock sections
With PE and N conductor connection
Fits on the reverse of flush mounting switches, with interlocking function for rear
mounting switches.
T0-.../E, ...EZ, ...Z UV-T0 1 off Fits on the reverse of
T3-.../E, ...EZ, ...Z 019925 flush mounting
P1-.../E, ...EZ, ...Z switches
T5(B)-.../E, ...Z UV-P3 With interlocking
P3-.../E, ...Z 048289 function for rear
mounting switches
Interlock extensions
Up to four off, 25 mm each, can be plugged onto interlock section
(An equal number of shaft extensions is required for this purpose)
Use ZVV-T0 only with T0/T3- UV-T0 ZVV-T0 10 off Use ZVV-T0 only with
.../Z and P1-.../Z 022298 construction type T0/
T3-.../Z and P1-.../Z
Use ZVV-P3 only with T5(B)- UV-P3 ZVV-P3 Use ZVV-P3 only with
.../Z and P3-.../Z 024671 construction type
T5(B)-.../Z and P3-.../Z
Shaft extensions
Up to four off, 25 mm each, can be plugged onto switch shaft
T0-.../Z, T0-.../V ZAV-T0 10 off
T3-.../Z, T3-.../V 027044
P1-.../Z, P1-.../V
T5(B)-.../Z ZAV-P3
P3-.../Z 029417
Shaft
Aluminium, length: 480 mm P5-.../V... ZAV-P5 1 off
P5-.../Z 280979
Interlock extensions und shaft extensions, complete
Only available in conjunction with a basic unit
Extension up to 25 mm when ordered +ZAV(X1)+ZVV(X1)-T0/P3 1 off
with basic unit 254546
Shrouds
For flush-mounting switches with T0-.../E H3-T0 1 off Cable entries
up to 4 contact units T3-.../E 093828 Quantity:
2 x o 20 mm
+ 2 x o 15 mm
Cross-section:
5 x 6 mm2
5 x 2.5 mm2
Cover for protection of terminals T5(B)-.../E, .../Z H1-T5 Can be used for input and/or
For up to 2 contact units 045062 output wiring
To cover terminals on 3-pole P1-.../E, .../EZ, H-P1 5 off Can be used for input and/or
switch-disconnectors .../Z, .../EA, .../V 017253 output wiring
To cover terminals on 4-pole P1-...N, ...HI11, H-P14 Can be used for input and/or
switch-disconnectors ...N...HI11 019626 output wiring
To cover terminals on 3-pole open P3-.../E, .../Z, .../ H-P3 The shroud is designed for
switch-disconnectors with N EA, .../V 021999 fitting onto both sides of the
neutral conductor and/or HI11 P3-...N, ...HI11, switch-disconnector. Parts
auxiliary contact modules fitted ...N...HI11 which are not required can
be broken off.
Keys
For KMS 1 individual lock ES-KMS1-T0 10 off
mechanism 231972
For KMS 2 - 10 individual lock ES-KMS(*)-T0
mechanism or KMS 201 - 400 231973
Individual key, corrosion-proof, for HS-SA(*)-T0 Master keys must always be
master key systems and recorded 256151 ordered separately.
individual lock mechanisms: state Please send or submit the
lock plan no. and lock security certificate with
repeat orders.
Ordering example:HS-
SA(A6294-1/2)-T0
For user to select indexing position S-T0 for all VR-T0 1 off
in which key can be withdrawn switching 089082
angles
Neutral terminals
For connection of 5th conductor
CI-K2-PKZ0-... K-CI-K1/2 20 off
207451
T5B-.../I4, K-CI-K4 20 off
Cl-K4-T5B-... 206916
P3-.../I4
CI-K4
T5-/I5, K50/1 10 off
CI-K5-T5- 098573
P3-/I5
CI-K, 100 A
T5-.../I5, K-CI-K5 20 off
CI-K5-T5-... 218488
P3-.../I5
CI-K5
Set of external fixing brackets
T5B-.../I4, AB-CI-K4/5 1 off For fixing CI-K4 and CI-K5 directly
T5-.../I5, 206914 to the wall.
P3-63/I4, One set comprises 4 brackets.
P3-100/I5,
ON-OFF switches TM
1
2
10
9
9
8
7
5
8
6
8 8
6 4
6 4 3
8 4
Control switch TM
2
10
11
9 11
O
HA
ND
5 AU
TO
0
6
6 3
1
4
4
4
System overview 7/53
Mini rotary switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM
Product features
Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price list
215351
1
2
215352
1
2
3
4
045484
1
2
3
4
5
6
045485
1
2
3
4
5
6
7
8
045498
1
2
3
4
5
6
7
8
9
10
11
12
On-Off switches, 90
1 1 Centre Front IP65 TM-1-8290/EZ 1 off
0 1
0 mounting 000693
1
2
F 056
mounting 015073
1
2
3
4
074877
1
2
3
4
5
6
077250
1
2
3
4
5
6
7
8
079623
1
2
3
4
5
6
7
8
9
10
11
12
Ordering 7/55
Changeover switch, hand/automatic switch
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM
Contact sequence Front No. of Design Protection Part no. Price Std.
plate no. poles type Article no. see price pack
list
Changeover switches
1 2 Without 0 1 Centre mounting Front IP65 TM-1-8220/EZ 1 off
1 2
position, 60 000692
F 072
081996
2 Centre mounting Front IP65 TM-2-8221/EZ
1 2
015197
2 Flush mounting Front IP65 TM-2-8221/E
1
2
3
4
5
6
7
8
084369
3 Centre mounting Front IP65 TM-3-8222/EZ
1 2
045493
3 Flush mounting Front IP65 TM-3-8222/E
1
2
3
4
5
6
7
8
9
10
11
12
086742
4 Centre mounting Front IP65 TM-4-8223/EZ
1 2
046119
4 Flush mounting Front IP65 TM-4-8223/E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
089115
5 Centre mounting Front IP65 TM-5-8369/EZ
1 2
046126
5 Flush mounting Front IP65 TM-5-8369/E
091488
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
093861
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1 2
position, 60 015137
1 Flush mounting Front IP65 TM-1-8210/E
F 071
096234
1
2
3
4
015166
2 Flush mounting Front IP65 TM-2-8211/E
098607
1
2
3
4
5
6
7
8
2 1
045491
F 249 3 Flush mounting Front IP65 TM-3-8212/E
010807
1
2
3
4
5
6
7
8
9
10
11
12
045847
4 Flush mounting Front IP65 TM-4-8213/E
013180
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 2
position, 90 017926
F 057
1
2
3
4
5
6
7
8
1 0 2
return from 032164
0
1
both
F 025 directions,
1
2
3
4
034537
0
1
1
2
3
4
5
6
7
8
Hand-Auto switches, 60
AUTO HAND AUTOM 1 Centre mounting Front IP65 TM-1- 1 off
HAND
8220F288/EZ
016925
F 288
1
2
3
4
AUTO
HAND
0
AUTO
1 Flush mounting Front IP65 TM-1-15431/E
0
HAND
025045
F 085 1 Centre mounting Front IP65 TM-1-15431/EZ
000691
1
2
3
4
Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price
list
Step switches
Mini rotary switches
2 3
1 039283
1 Centre mounting Front IP65 TM-2-8230/EZ
F 076 000701
1
2
3
4
5
6
041656
3 Centre mounting Front IP65 TM-5-8270/EZ
046124
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
4 steps, 60
1 Flush mounting Front IP65 TM-2-8231/E
1 2 3 4
2 3
1 4 044029
1 Centre mounting Front IP65 TM-2-8231/EZ
F 077 000700
1
2
3
4
5
6
7
8
046402
3 Centre mounting Front IP65 TM-6-8271/EZ
046128
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
5 steps, 60
1 Flush mounting Front IP65 TM-3-8232/E
1 2 3 4 5
2 3
1 4 039298
5
1 Centre mounting Front IP65 TM-3-8232/EZ
F 078 015592
1
2
3
4
5
6
7
8
9-
10
2 3
1 4 053521
6 5
1 Centre mounting Front IP65 TM-3-8233/EZ
F 079 015630
1
2
3
4
5
6
7
8
9
10
11
12
10 steps, 30
345
1 Flush mounting Front IP65 TM-5-8237/E
2
1
8
6
7 069150
10 9
1 Centre mounting Front IP65 TM-5-8237/EZ
F 011 015661
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Ordering 7/57
Control switch, step switch
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM
Contact sequence Front plate No. of Design Protection Part no. Price Std. pack
no. poles type Article no. see price
list
Step switches
1 2
0 058267
1 Centre mounting Front IP65 TM-1-8240/EZ
F 075 015226
1
2
3
4
060640
2 Centre mounting Front IP65 TM-2-8260/EZ
045483
1
2
3
4
5
6
7
8
063013
3 Centre mounting Front IP65 TM-3-8280/EZ
045496
1
2
3
4
5
6
7
8
9
10
11
12
3 steps, 45
1 Flush mounting Front IP65 TM-2-8241/E 1 off
0 1 2 3
1 2 3
0 065386
F 109 1 Centre mounting Front IP65 TM-2-8241/EZ
015256
1
2
3
4
5
6
067759
2 Centre mounting Front IP65 TM-3-8261/EZ
000698
1
2
3
4
5
6
7
8
9
10
11
12
070132
3 Centre mounting Front IP65 TM-5-8281/EZ
046125
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
4 steps, 30
234 1 Flush mounting Front IP65 TM-2-8242/E 1 off
0 1 2 3 4
1
0 072505
F 002 1 Centre mounting Front IP65 TM-2-8242/EZ
015506
1
2
3
4
5
6
7
8
074878
2 Centre mounting Front IP65 TM-4-8262/EZ
046120
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
077251
3 Centre mounting Front IP65 TM-6-8282/EZ
046129
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
5 steps, 30
1 Flush mounting Front IP65 TM-3-8243/E 1 off
0 1 2 3 4 5
2 34
1 5
0 079624
1 Centre mounting Front IP65 TM-3-8243/EZ
F 003 015537
1
2
3
4
5
6
7
8
9
10
6 steps, 30
1 Flush mounting Front IP65 TM-3-8244/E 1 off
0 1 2 3 4 5 6
2 34
1 5
0 6 081997
1 Centre mounting Front IP65 TM-3-8244/EZ
F 004 045495
1
2
3
4
5
6
7
8
9
10
11
12
9 steps, 30
1
2 3 4
5
1 Flush mounting Front IP65 TM-5-8247/E 1 off
0
7
6 009741
98
F 007
1 Centre mounting Front IP65 TM-5-8247/EZ
015565
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
7/58 Ordering
Control switches: group switches (OFF) spring-return switch, reversing switches, coding switches
TM Moeller HPL0211-2007/2008 http://catalog.moeller.net
Contact sequence Front plate Design Protection type Part no. Price Std. pack
no. Article no. see price list
Group switches
Mini rotary switches
2 groups, 60
2
1 2
Flush mounting Front IP65 TM-1-8310/E 1 off
1
0
0 084370
Centre mounting Front IP65 TM-1-8310/EZ
F 075 045479
1
2
3
4
3 groups, 30
2 3 Centre mounting Front IP65 TM-2-8311/EZ
3
1
0 045487
2
1
F 001
0
1
2
3
4
5
6
ON (OFF) switch
On switch 30
START START Centre mounting Front IP65 TM-1-8175/EZ 1 off
I
015690
1
2
F 023
ON-OFF switch 90/30 with spring-return from Start to 1
Reversing switches
60 Degree
1
0
2
Flush mounting Front IP65 TM-3-8401/E 1 off
2
015554
0
F 071
1
1
2
3
4
5
6
7
8
9
10
Coding switches
BCD code 0-9, 30
1
2 3 4
5
Flush mounting Front IP65 TM-2-8550/E 1 off
0
7
6 020300
98
F 007
Centre mounting Front IP65 TM-2-8550/EZ
000699
2
3
4
5
6
7
8
F 007
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ordering 7/59
Locks, front plates
http://catalog.moeller.net Moeller HPL0211-2007/2008 EZ/S-
Protec- Key withdrawable Part no. Price Std. pack Notes
tion type with suffix see price
Article no. list
0
size 30 x 30) 071438
TM 29 x 29 (for FS980-TM-EZ 50 off F023 F024 F025 F039 F053 F258 F259 F708
frame size 30 x 073811 23 234 234 234 234 234 234 345
1 1 1 5 1 5 1 5 1 5 1 5 2 6
30) 0 0 0 0 6 0
7
6 0
7
6 0
7
6 1
8
7
8 98 10 9
F001 F002 F003 F004 F005 F006 F007 F011
Switching angle 45
1 0 2 2 2 3 0 OFF
0 2 1 2 1 3 1 3 1 3 2 4 1 1 1 1
0 OFF 1 2 2 2 2
Switching angle 60
Switching angle 90
1 ON EIN 0 OFF 2
0 1 1 2
0 OFF AUS 1 2 MAN AUTO 1 3
General
Degree of protection IP65 (except CI-K2-80-A)
Five basic sizes (floor area of enclosure base)
Two mounting depths per base surface (exception: CI-K1
enclosure depth always 95 mm, CI-K2-80-. enclosure depth
1 always 80 mm)
Enclosure made of glass-fibre reinforced with self-extinguishing
polycarbonate, halogen free
Captive gasket
2 Enclosure base (RAL 9005)
Black (matt)
Enclosure cover RAL 7035, light grey (matt)
CI-K1H, CI-K2H:
metric cable entry knockouts in the enclosure sides, top and
bottom
CI-K3 to CI-K5:
metric cable entry knockouts in the sides, top and bottom and
also in the rear wall
Control cable entry from CI-K2
Metric cable glands to EN 50 262
Push-through metric cable grommets
a page 7/63, a page 13/35
3 Mounting systems for empty enclosures 2
Mounting rails to IEC/EN 60715
Sheet steel mounting plates
1 Accessories for mounting systems
a page 7/64
Mounting 3
Horizontal and vertical slot apertures for wall-mounting
enclosures
Captive cover screws
CI-K1 and CI-K2 with rubber feet on the back plate to
3 compensate for uneven walls
External mounting brackets for CI-K4 and CI-K5
3 a page 7/51
Mounting units
Miniature circuit-breakers
Rotary switch
Switch-disconnectors
Contactors
easy control relays
Timing relays
Control circuit devices
Laser labelling
We can label the cover surface of the CI-K small enclosures
according to your specifications. Wipe-resistant and permanent
with modern laser labelling method.
Please contact your sales office.
CI-K combination-* a page 7/62
Approved enclosures for use in UL/CSA a page A1/40
Cutouts in enclosure covers
We can produce cutouts in enclosure covers to your
requirements.
Please contact your sales office.
Ordering 7/61
Basic enclosures
http://catalog.moeller.net Moeller HPL0211-2007/2008 CI-K1, CI-K2, CI-K3
mm mm
S
105853
L
80 95
T 73
229304
With mounting plate CI-K2-100-M
Q 206893
100 100 With mounting plate CI-K2H-100-M
229306
M With mounting rail CI-K2-145-TS
206883
124
With mounting rail CI-K2H-145-TS
160
116
T 118 229305
With mounting plate CI-K2-145-M
Q 206894
100 145 With mounting plate CI-K2H-145-M
229307
With adapter plate Prepared for fitting a CI-K2-145-AD
DILE contactor with ZE overload relay 207632
U 93
R
120 125
U 128
R
120 160
Dimensions Enclosure depth: Dimensions from top Features Part no. Price Std. pack
1. Mounting depth for mounting plate Article no. see price
2. Mounting depth for mounting rails, list
7.5 mm height
3. 7.5 mm mounting depth with mounting
rails
mm mm
V 93
O
160 125
160
W 93
206899
P
200 125
160
mm mm
M with cover cutout Transparent hinged cover for devices CI-K2-80-K 1 off
requiring 2 to 4 space units. Push-through 211108
T cable entry diaphragm.
70
160
L M N O P Q R
Back plate: Back plate: Back plate: Back plate: Back plate:
2 x push-through mem- 2 x push-through mem- 2 X M25/20 2 X M32/25 2 X M50/40/25
brane up to max. o 8 brane up to max. o 11
mm mm
(not for CI-K2H)
7/64 Ordering
Accessories
TS-CI, M-CI Moeller HPL0211-2007/2008 http://catalog.moeller.net
Small enclosures, empty enclosures
For use with Mounting position Features Useful length Part no. Price Std. pack
Article no. see price list
mm
7.5
Blanking strips
To blank off one space unit; cannot be removed from outside
CI-K2-80-A VST1 5 off
211258
N terminals, PE terminals
Can be screwed onto support bosses in enclosure base plate
CI-K2-PKZ0-... 1 4 mm2 K-CI-K1/2 20 off
CI K1/2 207451
Dimensions Features For use with Enclosure depth Part no. Price Std. pack
Article no. see price
mm mm list
Knockouts
L 128
2 X M20
87
L 128
110
110
222
L 128
110
Hank nuts
To secure devices to mounting plate
M4 thread BT7488 100 off
088380
7
General
Standards IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA,
UL switch disconnector according to IEC/EN 60947-3
Lifespan, mechanical Operations x 106 0.1 0.1 0.08 0.08
Notes Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft
The rated uninterrupted current Iu is stated at max. connected cross-section.
For terminal capacity solid, stranded and flexible:
Max. 2 cross-section sizes difference admissible when using 2 conductors.
Technical data 7/69
Switch-disconnectors, auxiliary contacts
http://catalog.moeller.net Moeller HPL0211-2007/2008 P5
Switching capacity
Alternating voltage
Rated making capacity cos v = 0.35 A 850 1050 1700 2050
Rated breaking capacity, motor load 230 V A 800 900 1600 1800
switch cos v = 0.35 400 V A 750 850 1380 1650
500 V A 650 850 1250 1550
690 V A 340 340 400 400
Rated operational current 440 V load-break switch AC-21A Ie A 125 160 250 315
AC-3 motor load switch motor rating 230 V P kW 22 30 37 45
400 V P kW 37 45 55 75
690 V P kW 30 37 45 45
AC-23A Motor load switches (main 230 V P kW 30 30 37 55
switches maintenance switches) 400 V P kW 45 55 90 110
690 V P kW 37 37 45 45
DC
DC-1, Load-break switches L/R = 1 ms Rated operational current Ie A 125 160 250 315
DC-1, Load-break switches L/R = 1 ms Voltage per contact pair in series V 42 42 42 42
DC-23A, motor load switch 24 V Rated operational current Ie A 125 160 250 315
L/R = 15 ms Contacts Quantity 3 3 3 3
48 V Rated operational current Ie A 125 160 250 315
Contacts Quantity 3 3 3 3
60 V Rated operational current Ie A 125 160 250 315
Contacts Quantity 3 3 3 3
120 V Rated operational current Ie A 40 50 80 100
Contacts Quantity 3 3 3 3
Notes Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft
The rated uninterrupted current Iu is stated at max. connected cross-section.
For terminal capacity solid, stranded and flexible:
Max. 2 cross-section sizes difference admissible when using 2 conductors.
HI...-P1(P3)... HI...-P5...
Auxiliary contacts
Standards Control circuit isolators to IEC/EN 60947-5f
General
Standards IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnectors to IEC/EN 60947-3 Switch-disconnectors to IEC/EN 60947-3
Load-break switches to IEC/EN 60947-3 Load-break switches to IEC/EN 60947-3
Lifespan, mechanical Operations x 106 1 0.5 0.5 0.5 0.1 0.1 0.1
Maximum operating frequency Operations/h 3000 3000 3000 3000 50 50 50
Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
cyclical, to IEC 60068-2-30
Ambient temperature
Open C 2550 2550 2550 2550 2550 2550 2550
Enclosed C 2540 2540 2540 2540 2540 2540 2540
Mounting position As required As required As required As required As required As required As required
Mechanical shock resistance to IEC 60068-2-27 Half-sinusoidal g > 15 > 15 > 15 > 15
shock 20 ms
Contacts
Rated operational voltage Ue V AC 690 690 690 690 690 690 690
Rated impulse withstand voltage Uimp V AC 6000 6000 6000 6000 6000 8000 8000
Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3 III/3
Rated uninterrupted current
open Iu A 20 32 63 100 125 160 315
Enclosed Iu A 20 32 63 100 125 160 275
Load rating with intermittent operation, class 12
AB 25 % DF x Ie 2 2 2 2 2 2 2
AB 40 % DF x Ie 1.6 1.6 1.6 1.6 1.6 1.6 1.6
AB 60 % DF x Ie 1.3 1.3 1.3 1.3 1.3 1.3 1.3
Short-circuit rating
Fuse A gG/gL 20 35 80 100 200 160 315
Rated short-time withstand current (1 s current) Icw Arms 320 650 1300 1850 2000 3000 4200
Safe isolation to VDE 0106 Part 101 and Part 101/A1
between the contacts V AC 440 440 440 440
Switching angles 90 90 90 90 90 90 90
60 60 60 60 60 60 60
45 45 45 45
30 30 30 30
Contact units 11 11 10 10 3 3 3
Double-break contacts max. 22 max. 22 max. 20 max. 20 max. 6 max. 6 max. 6
Current heat loss per contact at Ie W 0.6 1.1 4.5 7.5 11 11 11
Terminal capacities
Solid or stranded mm2 1 x (1 2.5) 1 x (1 6) 1 x (2.5 35) 1 x (2.5 35) 1 x 70 1 x 95 150
2 x (1 2.5) 2 x (1 6) 2 x (2.5 16) 2 x (2.5 16) 2 x 25 2 x 25
Flexible with ferrule to DIN 46228 mm2 1 x (0.75 1.5) 1 x (0.75 4) 1 x (1.5 25) 1 x (1.5 25) 1 x 50 1 x 50 120
2 x (0.75 1.5) 2 x (0.75 4) 2 x (1.5 10) 2 x (1.5 10) 2 x 16 2 x 16
Flat conductor connection with busbars mm2 1 x (25 x 5)
2 x (20 x 3)
Terminal screw M3.5 M4 M6 M6 M6 M5, Allen key M12
Tightening torque Nm 1 1.6 4 4 5.6 14 25
Switching capacity
Alternating voltage
Rated making capacity cos v = 0.35 A 130 320 800 950 1600 1600 2390
Rated breaking capacity, motor load 230 V A 100 260 520 760 1280 1280 1910
switch cos v = 0.35 400 V A 110 260 600 740 900 900 1800
500 V A 80 240 480 590 880 880 1200
690 V A 60 170 340 420 340 340 420
Rated operational current 440 V load-break switch AC-21A Ie A 20 32 63 100 125 160 315
AC-3 motor load switch motor rating 230 V P kW 3 6.5 15 22 22 22 22
230 V Star-delta P kW 4 11 22 30 22 22 37
400/415 V P kW 4 12 22 30 37 45 55
400 V Star-delta P kW 5.5 18.5 37 45 37 45 55
500 V P kW 5.5 15 22 37 37 37 37
500 V Star-delta P kW 7.5 22 37 55 37 37 37
690 V P kW 4 15 22 30 22 22 37
690 V Star-delta P kW 5.5 22 37 45 22 22 37
AC-23A Motor load switches (main 230 V P kW 3.5 7.5 15 18.5 37 37 75
switches maintenance switches) 400/415 V P kW 6.5 13 22 30 45 55 132
500 V P kW 13 15 22 37 55 55 75
690 V P kW 22 30 30 30 37
Rated operational current control switch 230 V Ie A 6 10 16 16
AC-15 400/415 V Ie A 4 6 6 6
500 V Ie A 2 4 4 4
DC
DC-1, Load-break switches L/R = 1 ms Rated operational current Ie A 10 25 63 80 125 125 315
Voltage per contact pair in series V 60 60 60 60 42 42 42
DC-21A Rated operational current 240 V Ie A 1 1
Auxiliary contacts
Standards Control circuit isolators to IEC/EN 60947-5f
Rated insulation voltage Ui V AC 500 500
Rated uninterrupted current Iu A 10 10
Rated operational current
AC-15 with 230 V Ie A 6 6
380 V/415 V Ie A 4 4
Short-circuit rating
Maximum fuse A gG/gL 10 10
Terminal capacities
Solid mm2 0.75 2.5 0.75 2.5
Flexible with ferrule to DIN 46228 mm2 0.5 1.5 0.5 1.5
TM
General
Standards IEC/EN 60947, VDE 0660 UL, CSA
Control switches to IEC/EN 60947-5-1
Control circuit isolators to IEC/EN 60947-5-1
Mini rotary switches
Switching capacity
AC-23 Motor load switches 230 V AC, 3-pole kW 1.8
440 V AC, 3-pole kW 3
230 V AC, 1-pole kW 0.75
440 V AC, 1-pole kW 1.1
AC-15 Control switches 230 V AC, 1-pole A 2.5
General
Standards IEC/EN 60529
DIN 43660
EN 50262
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature C 2570
Ambient temperature with push-through cable entry C 2540
Protection type IP 65 IP 65 IP 65 IP 65 IP 65
Degree of protection with push-through cable entry IP 65 IP 65 IP 65 IP 65 IP 65
Dissipatable heat loss a Chapter 14, Technical data
Material characteristics
Material
Base, Cover Glass-fibre reinforced polycarbonate
Surface treatment Resistant to corrosion
Colour
Base RAL 9005, black (matt)
Cover Enclosure cover RAL 7035, light grey (matt)
Material properties
Electrical
Creepage resistance to IEC 60112
Base CTI175
Cover CTI175
Surface resistance to IEC 60093 O x 1013 1
Dielectric strength to IEC 60243-1 kV/mm 30
Thermal
Continuous thermal stability
Enclosures C -40120
Gasket C -4080
Mechanical
IK code to EN 50102 Please enquire
Weight of components fitted
per mounting rail kg 0.2 0.7 0.85 0.75 0.65
with mounting plate kg 0.85 0.9 1
Chemical resistance
Base, Cover
Resistant Acids < 10 %, mineral oil, petrol, grease, saline solution
Partially resistant Acids > 10 %, alcohol
Not resistant Alkalis, benzol
Push-through membrane (CI-K1/CI-K2) and sealing material
Resistant Acids < 10 %, alkalis,
alcohol, saline solution
Partially resistant Acids < 10 %, grease, benzol
Flush mounting
10 11
17
90
30
48
12.2
48
c20 35 75
Centre mounting
24.1 +0.4
0
45
48
54
48
+0.4
22.3 0
48 61
48
c21 35
c22
5 55 48
5
55
45
50
45
60
50
M4
54 28 5
Dimensions 7/77
Rotary switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 T0, T3
0
a
M4
50
36
50
60
48
25 48 36
48
O5
T3
O5
22. 5 5.5
3 +0
.4
0
c23
c24 35
55
65
75
65
M4
36
38, 54
100
R
63 36
O5
Part no. c20 c21 c22 c23 c24 c24 with c25 Part no. c20 c21 c22 c23 c24 c24 with c25
f/F F 4 ZAV f/F F 4 ZAV
T0-1... 41 61 77 48 86 102 202 72 T3-1... 44 64 80 51 86 105 205 79
T0-2... 50 70 87 57 96 112 212 72 T3-2... 56 76 92 63 101 115 216 79
T0-3... 60 80 96 67 105 121 221 91 T3-3... 67 87 103 74 112 128 228 101
T0-4... 69 89 106 76 115 131 231 91 T3-4... 79 99 115 86 124 139 239 101
T0-5... 79 99 115 86 124 140 240 T3-5... 90 110 126 97 135 151 251
T0-6... 88 108 125 95 134 150 250 T3-6... 102 122 138 109 147 162 262
T0-7... 98 118 134 105 143 159 259 T3-7... 113 133 149 120 158 174 274
T0-8... 107 127 144 114 153 169 269 T3-8... 125 145 161 132 170 185 285
T0-9... 117 137 154 124 162 178 278 T3-9... 136 156 172 143 181 196 296
T0-10... 126 146 163 133 172 188 288 T3-10... 148 168 184 155 193 208 308
T0-11... 136 156 173 143 181 197 297 T3-11... 159 179 195 166 204 219 319
One contact unit depth 9.5 mm One contact unit depth 11.5 mm
10 11
30
I ON
49
33
o
OFF
T3
o
OFF
12.2
54
25 c20
65 35
61
5 25
T0
17
M4
50
60
50
36
I ON
33
o
OFF
49 36
o
OFF
5
65 c23
c24 35 T3
f 38, F 54 1 00 M4
65
75
65
Rf a
63
Interlock extension possible with ZVV-T0 + ZAV-T0, F 4 x 25 = 100 mm 5
Not included as standard
7/78 Dimensions
Rotary switches
T0, T3 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Surface mounting
T0.../I1
Drilling dimensions
base
M4
M20
137
120
127
80 c25 27
171
M20 / M25
160
180
M20
I ON
127
137
120
o
OFF
o
OFF
80 c25 35
8 d = 4 8 mm
b + d F 47 mm
171
I ON
M20 /M25
180
160
o
OFF
o
OFF
100 c25 35
5 5
19 27
27 36 30 44 22:25 28
c20 30:23 26
48 100
R
10...11
0
12.5
36
3.2 3.2
30
17
36
12.2
22.3 + 0.4 30.5
0
Cylinder lock
73
73
73
73
46 30 46 30 46 30
48
Padlocking feature
73
48
48
48
46 46 46
48
Modules
Switched neutral N-P... F 3 padlocks
Auxiliary contact HI 11-P1/P3
a33
a3 d
b
d = 4 8 mm
H-P... b + d F 47 mm
b31
5 3 1 1 3 5
L3 L2 L1
N
HI 11
N
T3 T2 T1 N-P
6 4 2 2 4 6
I ON 12 13
37
o
88
86
OFF
14
88 F5
c2 37
I ON
o M6
30
48
88
73
OFF
.5
25 25
88 48
c2 37
f 38, F 54
R f 100
88 b
F5
c2
4.1 4.5
27
25
I ON
12 13
o
37
88
88
OFF
o
OFF
80/90
80/90
44 14
40.5 100
16.5
5 5.5
I ON
oOFF
88
48
30
73
.5
o
OFF
25 25
88 44 48
a
12 R f 100
16.5 40.5
M25
M25 M50
M32 M20
240
280
M20
b
d = 4 8 mm
b + d F 47 mm
I ON
240
o
193
OFF
o
OFF
142
160 c22 44
I ON
280
o
233
OFF
o
OFF
182
200 c22 44
6.5
20
6 36
52
7/82 Dimensions
Rotary switches
T6, T8 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
Flush mounting
T6-3-8212/E/HI12
T8.../E/HI12
58
b2
a2 150 5
c2 c30
T6-160-6/V/SVB-SW/HI11 T8-3-8342/V/SVB-SW/HI11
6.4 H-T6-100 19
2
7
H-T8
118
88
68
108
130
68
76 93 9
4.5
2
224 216 73
200 104 172.8 9.2
5.5 130 315 86.5
1 218
0
R 10 250 7
5 1 0
R 10
Drilling dimensions
Part no. a2 b2 c2 c30 d1 d2 x1 y1 door
d2
y1
d1
x1
T6: 4 M5 x 20
T8: 4 M6 x 20
d = 4 8 mm
b + d F 47 mm
Dimensions 7/83
Switch-disconnectors
http://catalog.moeller.net Moeller HPL0211-2007/2008 P1, P3
10 11
12.5
b22
5 3 1
I ON L3 L2 L1 12 13
37
30
b3
0
b2
OFF
T3 T2 T1
6 4 2
12.2 22.3 +0.4
0 14
a2 a3 5
c2 c21
P1.../EZ = c2 + 5 mm
b
c22 a32 a32 L1 L2 L3
L1 L2 L3 L1 L2 L3
d = 4 8 mm
b + d F 47 mm
45
b3
HI11
45
b3
N
T1 T2 T3
T1 T2 T3
a31 T1 T2 T3
49 28
a4
55
Rear mounting
Drilling dimensions
Bottom Door
P/Z P1/Z
5 5.5
5
36
M4
65
b22
22.3
+0.4
0
36
b3
c31 c32
b2
5
P3/Z
a2 a3 5 5.5
M4
75
48
30
.5
3 c21
c25
c20
100 25 48
38, 54 R
Part no. a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31
P1 48 49 53.5 65 48 87 15 15 83 48 70 65 17 180 32 49
P3 87 72 71.5 87 87 125 18 15 114 87 83 87 27 175 60
Part no. c2 c3 c20 c20 with c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
f/F F 4
ZAV/ZVV
P1 59 86 96 112 212 35 32 65 68 58 35 77 25 25 27
P3 59 82 103 118 218 37 41 63 81 65 44 90 25 25 29
7/84 Dimensions
Switch-disconnectors
P1, P3 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
10 11
b31
I ON 5 3 1
y
12 13
N
o
b21
30
b3
37
OFF
y
N
o
OFF
6 4 2
12.2 14
a21 a3
F5
25 c2 c27
36
M4
65
+0.4
b22
22.3 0
36
b31
I ON 1 3 5
N P3/V/SVB
b21
o
b3
OFF
N 5 5.5
o
OFF
2 4 6
3
a21 a3 c25
c20 100 M4
75
48
30
Rf
.5
f 38, F 54
25 48
Interlock extension possible with ZVV-...+ZAV... F 4 x 25 = 100 mm
Not included as standard
M4
M25 M25
F8
M25
160
171
b23
Part no. a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31
P1.../I2 48 49 53.5 65 48 100 15 15 83 48 70 65 17 180 35.5 49
Part no. c2 c3 c20 c20 with c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
f/F F 4
ZAV/ZVV
P1... 59 86 96 112 212 35 32 65 68 58 35 80 25 25 27
Dimensions 7/85
Switch-disconnectors
http://catalog.moeller.net Moeller HPL0211-2007/2008 P5
q 68
q 88
88
68
b
6
26 30
a 8 35
c
P5-.../EA/SVB(-SW)
M5 HI10
b2
88
68
88
q 88
b2
F5
a1 21 c 26
a2 a a2 49.3
Rear mounting
q 68
q 88
b1
6
26 30
F5
2
a1 c 8 35
a c1
P5-.../V/SVB(-SW)
b2
88
q 88
b
b2
F5 26
100
Rf
a2 a a2 c
c1 49.3
Part no. a a1 a2 b b1 b2 c c1
P5-125/160 112 36 38 108 120 76 91 f 130 F 287
P5-250/315 145 44 52.5 126 144 88 98 f 140 F 280
7/86 Dimensions
Switch-disconnectors
P3 Moeller HPL0211-2007/2008 http://catalog.moeller.net
Rotary switches, switch-disconnectors
M25
M32 M20
193
b23
142
a23 95 29 95 44
M25
M50 M20
233
b23
182
Part no. a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31
P3-63/I4 87 72 71.5 87 87 160 18 15 114 87 83 87 27 240 35.5 60
P3-100/I5 87 72 71.5 87 87 200 18 15 114 87 83 87 27 280 35.5 60
Part no. c2 c3 c20 c20 with c21 c22 c23 c24 c25 c27 c28 c31 c32 c33
f/F F 4
ZAV/ZVV
P3-63 59 82 103 118 218 37 41 63 81 65 44 125 25 25 37
P3-100 59 82 103 118 218 37 41 63 81 65 44 125 25 25 37
Dimensions 7/87
Mini rotary switches
http://catalog.moeller.net Moeller HPL0211-2007/2008 TM
3
8
4.8
3.2
M3 M3
28
30
28 20
28
30 c20
10
4.2
M4 M4
38
48
28
30
38
48
c21 35
Centre mounting
3.2
F 5.5 1.7
17/19
24.1 +0.4
0
17.9
16.2 +0.2
30
28
0 +0.4
22.3 0
30 c20 12 23
17/19
5.5 3.2
1.7
24.1 +0.4
0
17.9
28
30
16.2 +0.2
0 +0.4
30 c20 12 35 22.3 0
TM-.../IVS TM-.../IVS/S
Part no. c1 c2
TM-1... 44 21
45
60
45
60
TM-2... 46 26.5
One contact unit depth 12 mm
Note 1)) Drilling dimensions either 16.2 mm = without reduction RMQ16; 22.3 mm = with reduction RMQ Titan
7/88 Dimensions
Small enclosures
CI-K Moeller HPL0211-2007/2008 http://catalog.moeller.net
Small insulating material enclosures Mounting rails
easy Relay, easy Control, easy MFD
CI-K1...-95-TS TS-CI-K1
17.5
35
4.7 7.5
39 61
5 45 72
1.5
12
127
137
120
82
74
4.5 37.5 57.5 39
80 95
7.5
92
35
22
116
18
a l
77 92
100
116
160
171
181
4.5 47.5 b 46
100 a
52
22
20
7.5
5.3 a
70
116 l
5 65
a l
1.5
93 108
27
152
200
210
222
140
5.5 50.5 b 70
120 a
70
24.5
21
Dimensions 7/89
Small enclosures
http://catalog.moeller.net Moeller HPL0211-2007/2008 CI-K
Small insulating material enclosures Mounting plates Mounting rails
35
30
23
CI-K4-160-... 160 107.5
7.5
143.8
5.2 7.5
a
74 27 l
5.3 a l
5.6
90 128 143
154
193
154
240
194
80
1.5
5 52.5 72.5 72
160 125 142
35
50.5
183
5.2 7.5
7.5
91 27 a
l
5.6
5.3
170
181
233
110
234
280
1.5
5 73.5 b 87
200 a 182
Typ a b a l
CI-K5-125-... 125 51.5 168 183
CI-K5-160-... 160 85.5
Basic enclosures
CI-B, CI-C, CI-D
c Part no. a a1 b b1 b2 b3 c c1 c2
c1
4,5 12 c2 CI-B 87 71 149 106 128 10.5 128 115 84.4
M4 CI-C 110 95 165 122 144 10.5 128 115 84.4
CI-D 110 97 222 179 201 10.5 128 115 84.4
b1
b2
b2
b
a1
b3