Chapter 1
Hardware description
Chapter 2
Hardware configuration
Chapter 3
External connections
0-1
0-2
1.1
Overview
The NPRAE (New Primary Rate Access E1) board replaces the PRA2 board.
This board can be used to connect an Alcatel-Lucent OmniPCX Enterprise Communication
Server to:
-
Note:
For DASS2 and DPNSS, access 0 is the only access available.
At initialization, binaries are sent according to the type of board declared on the PCX. These
types are:
-
Clock synchronization can be obtained from the board access if needed to synchronize the
node.
NPRAE board configuration is described in NPRAE - Hardware configuration .
NPRAE board connection is described in NPRAE - External connections .
Environment
___change-begin___
1.2
!"
1-1
Chapter
___change-end___
1.3
Functional Units
The NPRAE board is composed of the following functional units:
1-2
1 switching module
2 ISDN E1 interfaces
!"
2.1
2.2
Overview
___change-end___
___change-begin___
This board is equipped with an FA1 fuse (3 Amperes, 125 VDC) to protect board power supply
against overvoltages.
2.3
Strappings
Strappings shown on a gray background are factory set
#
!"$%& !"
2-1
Chapter
___change-end___
___change-begin___
___change-end___
___change-begin___
Strap JX6 indicates to the management application which type of configuration (120 or 75
ohms) to use.
___change-begin___
___change-end___
___change-begin___
Straps JX13 and JX23 connect TXB-1 and TXB-2 to ground for 75 ohm terminations.
Straps JX14 and JX24 connect RXB-1 and RXB-2 to ground for 75 ohm terminations.
Straps JX15 and JX25 adapt the interface to the terminations (75 or 120 ohms).
2-2
#
!"$%& !"
___change-end___
2.4
Meaning of LEDs
LED
CPU (green LED)
Explanation
AIS
RAI
NOS
Loss of Signal
Note:
No led is available for CRC error ratio.
Cadence (rate)
Steady
Initializing
Loading
10 ms (on)/ 10 ms (off)
CPU standby
#
!"$%& !"
2-3
Chapter
2-4
Cadence (rate)
Meaning
Checksum error
#
!"$%& !"
3.1
Connection
The NPRAE board is inserted in an interface position in the ACT shelf.
by cable: connection to the main distribution frame is via a type 2 cable (see TY2
96PTSDIN cable - Hardware description),
" !"" !"
3-1
Chapter
Note:
the second T2 interface is distributed on the pairs corresponding to the first T0 interface of a BPRA
board.
by coaxial cable: connection to the data transmission equipment is via 4 type 5 cables (see
module TY5 9PTS DIN/BNC cable - Hardware description),
Caution:
the NPRAE board uses the same 75 ohm cables as the PRA2 board, but the first link reception
cable (75 ohms) must be connected to position 1820, instead of position 1012 for the PRA2
board.
3.2
by patch panel (VH cabinet only): connection is directly performed using the patch panel:
16-port 4-wire module (see Patch Panel - 16 ports module - 16 ports module).
NOTES
L1_TXB_RING
L1_TXA = E1 transmission
L1_RXA = E1 reception
1
2
L1_TXA_TIP
L1_RXA_TIP1
L1_TXA_TIP
L1_RXB_RING1
L1_TXB_RING
5
6
7
GND
GND
GND
10
L2_TXA_TIP
11
L2_RXA_TIP1
75 Ohm connections
L2_TXB_RING
L2_TXA_TIP
12
L2_TXB_RING
13
AL1
L2_RXB_RING1
14
L2_RXA_TIP1
AL2
L2_RXB_RING1
15
L2_TXA_TIP
GND
L2_TXB_RING
16
GND
17
A5V
18
L2_TXA_TIP
19
L2_RXA_TIP1
20
L2_TXB_RING
L1_RXA_TIP1
L2_RXB_RING1
L1_RXB_RING1
ALCV
21
3-2
22
UART_RTS
23
GND
24
GND
" !"" !"
NOTES
Strap
GND
GND
UART_TX
27
L2_RXA_TIP1
28
L2_RXB_RING1
29
UART_RX
30
GND
GND
31
Strap
GND
32
GND
" !"" !"
3-3
Chapter
3-4
" !"" !"