Вы находитесь на странице: 1из 1

AWS D1.1/D1.

1M:2015

CLAUSE 5. FABRICATION

Table 5.5
Camber Tolerance for Typical Girder
(see 5.22.3)

Table 5.6
Camber Tolerance for Girders without a
Designed Concrete Haunch (see 5.22.4)

Camber Tolerance (in inches)

Camber Tolerance (in inches)

a/S

a/S

Span

0.1

0.2

0.3

0.4

0.5

Span

0.1

0.2

0.3

0.4

0.5

100 ft

9/16

1-1/4

1-7/16

1-1/2

100 ft

1/4

1/2

5/8

3/4

3/4

< 100 ft

1/4

1/2

5/8

3/4

3/4

< 100 ft

1/8

1/4

5/16

3/8

3/8

Camber Tolerance (in millimeters)

Camber Tolerance (in millimeters)

a/S

a/S

Span

0.1

0.2

0.3

0.4

0.5

Span

0.1

0.2

0.3

0.4

0.5

30 m

14

25

34

38

40

30 m

13

17

19

20

< 30 m

13

17

19

20

< 30 m

10

10

Table 5.7
Minimum Fillet Weld Sizes (see 5.13)
Base Metal Thickness (T)a

Minimum Size
of Fillet Weldb

in

mm

in

mm

T 1/4

T6

11/8c

3c

1/4 < T 1/2

6 < T 12

3/16

1/2 < T 3/4

12 < T 20

1/4

3/4 < T

20 < T

5/16

For nonlow-hydrogen processes without preheat calculated in


conformance with 4.8.4, T equals thickness of the thicker part joined;
single-pass welds shall be used.
For nonlow-hydrogen processes using procedures established to
prevent cracking in conformance with 4.8.4 and for low-hydrogen
processes, T equals thickness of the thinner part joined; single-pass
requirement shall not apply.
b Except that the weld size need not exceed the thickness of the thinner
part joined.
c Minimum size for cyclically loaded structures shall be 3/16 in [5 mm].