Wireless Heating Room Thermostat with more than one


receivers 433/868HMZ

Adjustabeforheatingsystem.
Two-position control with ON / OFF
Battery-powered DC 3 V (2x 1,5V AA A batteries)
Receiver AC 250 V 16 A (SPDT)

Application
WT-08 wireless room thermostat is used in heating system to maintain the selected room temperature.
Typical use:

Residential buildings

Apartments

Commercial spaces

Light industrial buildings

In conjunction with

zone valves, thermal valves

boiler/water heating system or electrice heating system

Functions
The controller acquires the room temperature with its integrated sensor and maintains the set point by delivering control
commands. The switching differential is 0.5 C.

Operating
Key features of WT-08 room thermostat:

LCD display

NTC 10K sensor

Set point of room temperature shall be set by pressing buttons + , -.The controller acquires the room temperature with
its integrated sensor. If the room temperature falls below the selected set point, the heating contact will close. If the room
temperature exceeds the selected set point, the cooling contact will close.

The digital display shows the actual room temperature, the setting room temperature and the symbol of the operating
mode currently active. When the heating output is activated, the heating

symbol

appears, or vice versa.

Mechanical Design
The unit consists of two parts:

A plastic housing with digital display, which accommodates the electronics, the operating elements and the built-in

room temperatures sensor.

A mounting base. The housing engages in the mounting base and snaps on. The base carries the screw terminals.

Battery Indicator

Weekday
Clock

Room Temp. Display

Set Temp.
Heating Icon.

Programmable Period

PRG. Button

On/off Button

Modes Select

Technical Data
Operational data
Switching capacity
Voltage

DC 3 V (2 x 1.5 V AA A batteries)

Switching differential SD

0.5 C

Set point setting range

530 C

Increments

0.5 C

Battery life

1 year (AAA Alkaline batteries)

Environmental conditions
Operation
Climatic conditions
Temperature

class 3K5
0+50 C

Temp. & Parameters setting

Humidity

<95 % r.h.

Pollution degree

normal

Transport / Storage
Climatic conditions
Temperature
Humidity

class 2K3/1K3
-25+60 C

<95 % r.h.

Mechanical conditions

class 2M2

Norms and standards


Standards

CE conformity

Screw terminals

for 2 x 1.5 mm2 or 1 x 2.5 mm2

Weight

0.14 kg

Colour

white

min.(0.5 mm2 )

Plug In Receiver ( First receiver)

Operating voltage

Voltage-free

Frequency

868M Hz/433Mhz

Relay operating voltage

12 V (DC)

Relay operating current

16A (SPDT)

Operate

plug in directly

ID Address study for plug in receiver


LED Indicator
ID Study Button

1.

Press the ID study button(like left picture),then you will find the LED(Which marked SET) flashing

2.

Then OFF the transimter and press ID study button for 3 seconds,then screen will show the IP adress,and press ID
studybutton again the LED stop flashing . Congratulation! You finish the ID address study.

RRG. Setting
Press P button for 2 3 seconds.
You will see 00:00 hour information on the upper left-hand corner. Set the time of first period by up and down button. Each
press of P button will into next time setting. (mins.--hours)
Press P button again. Set the desired temp. of first period by up and down button.
Use the same way the set the whole 5+1+1 days PRG schedule.

Save your settings by pressing ON/OFF button or wait about 15 seconds.


Example:
Monday to Friday

Saturday

Sunday

Period

Time

6:30

8:00

18:00

22:30

8:00

10:00

18:00

23:00

9:00

12:00

19:00

0:00

Temp.

21C

18C

21C

16C

21C

21C

21C

16C

23C

21C

16C

21C

Hour/Date Setting
Long Press P button for 2-3 seconds
You will see 00:00 hour information. Set the minute with up and down buttons.
Proceed with P button.
Set the hour with up and down buttons.
Proceed with P button.
Select the day with up and down buttons.
Proceed with P button.
Save your settings by pressing ON/OFF button or wait about 15 seconds.

Sensor Calibration
If the temperature on the display does not agree with the room temperature effectively measured, the temperature sensor
can be recalibrated. For that purpose, long press M button for 2 seconds when the controller is off. Then, the temperature
displayed can be changed by a maximum of +/- 8 C by pressing the up and down buttons. Five seconds after the last
push of a button, the controller will automatically return to off status. Or, the controller will return to main display by
pressing On/Off button.

MOUNTING OF THE CONTROL UNIT


For wall mounting, first the wall bracket should be mounted on the wall, then the control unit and the wall bracket must be
fitted as shown in the following figure.

INSTALLING THE RECEIVER UNIT


Plug into the socket directly

Mounting, Installation and Commissioning

The room thermostat should be located where the air temperature can be sensed as accurately as possible, without
getting adversely affected by direct solar radiation or other heat or refrigeration sources.
Mounting height is about 1.5 m above the floor.

The unit can be fitted to most commercially available recessed conduit boxes or directly on the wall.
Only authorized personnel may open the unit to perform service. (Caution: AC 250 V) . The unit must be isolated from the
mains supply before opening.
When installing the unit, fix the base plate first, then hook on the thermostat body and make the electrical connections.
Then fit the cover and secure it (also refer to separate mounting instructions).
The thermostat must be mounted on a flat wall.
The local electrical regulations must be complied with.
If there are thermostatic radiator valves in the reference room, set them to their fully open position.
The room thermostat is maintenance-free.
The thermostat housing is made of plastic.

Dimensions