Вы находитесь на странице: 1из 3

Intertek Testing Services

IEC 60335-1 IEC 60335-2-65

Household and similar electrical appliances Safety Part 1: General requirements.


Part 2-65: Particular requirements for air-cleaning appliances

Report Reference No. .............. : SHJ-12-13-004


Client Reference No..: SAR 1056052
Date of issue .............................. : 26-12-2013
Testing Laboratory ........................ : Intertek Testing Services
Address ..................................... : Bukhatir Building, Al Qassimiya Road, Industrial Area Sector 6, Sharjah,
4660 - United Arab Emirates

Applicants name ........................... : 3M Gulf LTD


Address ..................................... : P.O. Box 20191, Dubai, UAE
Test specification:
Standard .................................... : IEC 60335-1: 2010 (5th Edition): Household and similar electrical appliances
Safety Part 1: General requirements
IEC 60335-2-65: 2008 (2.1 Edition): Particular requirements for air-cleaning
appliances

Test item description ............... : Ultra Clean Air Purifier


Trade Mark ................................ :

Manufacturer .............................. : 3M
Country of Origin ........................ : Taiwan
Model/Type reference ................ : MFAC-01
Ratings ...................................... : 220V, 50Hz, 73W

Testing....:
Date of receipt of test item..: 02-12-2013
Date of performance of tests..: 05-12-2013 to 12-12-2013

General Product information: Ultra Clean Air Purifier


Tested By: Rowel Nachor

Reviewed by: Wilston Veigas

Page 1
Intertek Testing Services

IEC 60335-1 IEC 60335-2-65


Possible test case verdicts:
-test case does not apply to the test object.: N/A
-test object meet the requirement..: P (Pass)
-test object does not meet the requirement..: F (Fail)

Overall Verdict : Pass


No. Test Parameter IEC 60335-1 IEC 60335-2-65 Remarks Results
1 Marking and instructions Clause 7 Marking is still legible after the P
test.
2 Protection against Clause 8 No access to live parts P
accessibility to live parts
3 Power input Clause 10.1 Power deviation within limits P
4 Temperature rise (heating) Clause 11 Critical parts of EUT does not P
exceed temperature rise limit
5 Moisture Resistance Clause 15.3 The EUT withstand the tests of P
Clause 16 after the humidity
conditioning
6 Leakage current and electric Clause 16 Leakage current does not P
strength at normal operation exceed the limit. No insulation
conditions breakdown
7 Stability and mechanical Clause 20 Does not overturn in horizontal P
hazards inclined plane
8 Plug: configuration, SASO 2203 Plug in accordance with the P
dimensions and ratings standard

Remarks:

1) The appliances rated frequency is 50 Hz whereas for KSA rated frequency is 60 Hz but all the
tests were carried out with 60Hz.
2) Arabic manual is not provided along with the product.
3) The standard says, This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. But the products instruction manual states, Care must be
taken to keep the air purifier out of reach of children or pets
4) The instruction manual does not contain the substance of the following.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.

Page 2
Intertek Testing Services

Photo Documentation

Fig(a). Complete sample

Fig(b). Rating label

Page 3

Вам также может понравиться