Академический Документы
Профессиональный Документы
Культура Документы
Manufacturer .............................. : 3M
Country of Origin ........................ : Taiwan
Model/Type reference ................ : MFAC-01
Ratings ...................................... : 220V, 50Hz, 73W
Testing....:
Date of receipt of test item..: 02-12-2013
Date of performance of tests..: 05-12-2013 to 12-12-2013
Page 1
Intertek Testing Services
Remarks:
1) The appliances rated frequency is 50 Hz whereas for KSA rated frequency is 60 Hz but all the
tests were carried out with 60Hz.
2) Arabic manual is not provided along with the product.
3) The standard says, This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. But the products instruction manual states, Care must be
taken to keep the air purifier out of reach of children or pets
4) The instruction manual does not contain the substance of the following.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
Page 2
Intertek Testing Services
Photo Documentation
Page 3