Please Note: This operation and instruction manual is for the training of
the OEM and for the OEM to use to train their customers. This document
is not to be used as the complete system manual.
MANUAL REGENERATION Arrow will point to Regen if a
regeneration is expected Tonight.
NOTE: For softeners, if brine tank does not contain
salt, fill with salt and wait at least 2 hours before
regeneration.
If you need to initiate a manual regeneration, either
immediately, or tonight at the preprogrammed time
(typically 2 a.m.), complete the following steps.
For Immediate Regeneration:
Press and hold UP and DOWN simultaneously until For Regeneration Tonight:
valve motor starts (typically 3 seconds). Press and release UP and DOWN simultaneously
(notice that arrow points to Regen).
To shut off water to the system, please position arrow handles as shown in the bypass operation diagram
below. If your valve doesnt look like the diagram below, contact your service technician for instructions
on how to shut off water.
NORMAL OPERATION BYPASS OPERATION
Treated Supply Water Supply Water Supply Water
Water Exits Enters Exits Enters
Table of Contents
Control Valve Function and Cycles of Operation Control Valve Function and Cycles of Operation 1 - 2
OEM General Programming Instructions Programming 1
OEM System Setup Programming 1
Installer Displays/Settings Programming 3
User Displays/Settings Programming 4
Drawings and Part Numbers
Front Cover and Drive Assembly Drawings and Part Numbers 1
WS1TC Drive Cap, Pistons and Spacer Stack Drawings and Part Numbers 2a
WS1.25TC Drive Cap, Pistons and Spacer Stack Drawings and Part Numbers 2b
WS1 & WS1.25 Identification Figure Drawings and Part Numbers 2c
FOR INFORMATION COMMON TO ALL 1 & 1.25 CONTROL VALVES REFER TO THE WS1&WS1.25 COMMON
INFORMATION MANUAL
The common manual contains the Table of Contents shown below
Other Drawings and Part Numbers
Compliance Table No page number
Injector Cap, Injector Screen, Injector, Plug and O-ring Drawings and Part Numbers 3a
Injector Order Information Drawings and Part Numbers 3b
Injector Graphs US Units: Injector Draw, Slow Rinse and Total Flow Rates Drawings and Part Numbers 3c-3d
Injector Graphs Metric Units: Injector Draw, Slow Rinse and Total Flow Rates Drawings and Part Numbers 3e-3f
Refill Flow Control Assembly and Refill Port Plug Drawings and Part Numbers 4
Drain Line 3/4 Drawings and Part Numbers 5
Drain Line 1 Drawings and Part Numbers 6
Water Meter, Meter Plug and Mixing Valve Drawings and Part Numbers 7
Installation Fitting Assemblies Drawings and Part Numbers 8a 8b
Bypass Valve Drawings and Part Numbers 9
Flow Diagrams Service and Backwash Drawings and Part Numbers 10
Flow Diagrams Downflow and Upflow Drawings and Part Numbers 11
Flow Diagrams Rinse and Fill Drawings and Part Numbers 12
WS1 Service Spanner Wrench Drawings and Part Numbers 13
General Information General Information 1
General Warnings (Must appear in OEMs manual) General Information 1
Specifications which must be included in OEMs Manual General Information 2
Quick Reference Specifications General Information 2
Drive Assembly General Information 3
Drive Cap Assembly, Main Piston and Regenerant Piston General Information 3
Spacer Stack Assembly General Information 4
Injector Cap, Screen, Injector Plug and Injector General Information 4
Refill Flow Control Assembly or Refill Port Plug General Information 4
Drain Line Flow Control and Fitting Assembly General Information 5
Water Meter or Meter Plug General Information 6
Mixing Valve General Information 6
Installation Fitting Assemblies General Information 6
Bypass Valve General Information 7 - 8
Installation Installation 1 - 2
Service Instructions Service Instructions 1 - 5
Troubleshooting Troubleshooting 1 - 2
Limited Warranty Last Page
Control Valve Function and Cycles of Operation Page 1 WS1TC & WS1.25 TC Manual
The time clock control valve can be set to perform downflow regeneration or simply backwash. The time clock control valve has
two calendar options for regeneration frequency:
1. an option where the user can choose the number of days (1-99) between each regeneration; and
2. a seven-day option where the user can choose which day(s) of the week a regeneration should occur.
The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is capable of routing the flow
of water in the necessary paths to regenerate or backwash water treatment systems. The injector regulates the flow of brine or
other regenerants. The control valve regulates the flow rates for backwashing, rinsing, and the replenishing of treated water into a
regenerant tank, when applicable.
The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts and snap type latches are used.
Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required to service the valve include one
small blade screw driver, one large blade screw driver, pliers and a pair of hands. A plastic wrench is available which eliminates the
need for screwdrivers and pliers. Disassembly for servicing takes much less time than comparable products currently on the market.
Control valve installation is made easy because the distributor tube can be cut above to below the top of tank thread. The
distributor tube is held in place by an o-ring seal and the control valve also has a bayonet lock feature for upper distributor baskets.
The AC adapter power pack comes with a 15 foot power cord and is designed for use with the control valve. The AC adapter power
pack is for dry location use only. If the power goes out, only the time of day needs to be reset. All other values are permanently
stored in the nonvolatile memory.
Table 1 shows the time for the backwash, regenerative, and rinse cycles for the ten available programming options. Six different
programs are available for a softener, one for a regenerative filter, and three programs for backwash only filters. When the control
valve is used as a:
1. softener, one or two backwashes occur and refill always occurs after the rinse cycle (P0 through P5);
2. regenerative filter, one backwash occurs and refill always occurs after the rinse cycle (P6); and
3. backwashing filter, one backwash occurs (P7 through P9).
Table 1
Regeneration Cycles and Times for Different Programs
1
Noryl is a trademark of General Electric.
WS1TC & WS1.25 TC Manual Control Valve Function and Cycles of Operation Page 2
The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed regeneration
time or to have the regeneration occur immediately. Simultaneously press the UP + DOWN buttons to start a regeneration at the
next delayed regeneration time. If a regeneration is to occur today an arrow will point to regeneration. For immediate regeneration,
simultaneously press and hold the UP + DOWN buttons for three seconds.
When in regeneration, step through the different regeneration cycles by simultaneously pressing the UP + DOWN buttons.
Programming Page 1 WS1TC & WS1.25 TC Manual
The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation. These
procedures are:
These procedures can be accessed in any order. Details on each of the procedures are provided below and on the following pages.
When in operation, normal user displays show the time of day or days remaining before regeneration. When stepping through a
procedure, if no buttons are pressed within five minutes the display returns to a normal user display. Any changes made prior to the
five minute time out are incorporated.
To quickly exit Installer Displays & Settings or OEM Setup, simultaneously press SET HOUR + DOWN. Any changes made prior
to the exit are incorporated.
To reinitialize the control valve, check to make sure the valve is in the User Display. Then simultaneously press SET HOUR +
DOWN or unplug power source plug (black wire) on the circuit board, and plug back in.
STEP 1SS From normal mode, press SET HOUR + UP buttons simultaneously for 3 seconds
and release. Then press SET HOUR + UP buttons simultaneously for 3 seconds and release.
STEP 2SS
STEP 2SS Choose the desired program by pressing the UP or DOWN buttons. Prior to
selecting a program, verify the correct valve body, main piston, regenerant piston, and stack are
being used, and that the injector or injector plug(s) are in the correct locations. See Compliance
Table in Service Instructions under Injector Cap, Screen, Injector Plug and Injector section and
Figure 6. Press SET HOUR button to go to Step 3SS.
STEP 3SS STEP 3SS If program P0 through P6 was selected, enter in the minutes of fill using the UP or
DOWN buttons. The allowable values vary from a low of 1 to a high of 99. If program P7, P8
or P9 was selected, dashes will appear for minutes of fill. Press SET HOUR button to go to Step
4SS. Note: For each minute of fill 0.5 gallons of water is added to the solution tank. With salt
(sodium chloride) this equates to approximately 11/2 pounds of salt per minute of fill.
WS1TC & WS1.25 TC Manual Programming Page 2
STEP 4SS
STEP 4SS Use UP or DOWN buttons to switch
between:
or
1-99 Days Between Regen; or
7-Day.
Press SET HOUR button to go to Step 5SS.
STEP 5SS
STEP 5SS Use UP or DOWN buttons to switch
between 60 Hz or 50 Hz option. Press SET HOUR button
or
to go to Step 6SS.
B C
STEP 1ID Installer Displays & Settings (1-99 Days Between Regeneration option)
STEP 1ID From normal mode, press SET HOUR + UP buttons simultaneously for 3 seconds
and release.
STEP 2ID
STEP 2ID Regeneration Time: Set the clock to the hour the regeneration should occur by using
the UP or DOWN buttons. An arrow points to PM after 12. Press SET HOUR to go to STEP 3ID.
STEP 3ID
STEP 3ID Days To Regen: Set the number of days between regenerations. The allowable range
is 1 to 99. Press SET HOUR to exit Installer Displays & Settings.
Return to
Normal Mode
Installer Displays & Settings (7 day option)
STEP 1I7
STEP 1I7 From normal mode, press SET HOUR + UP buttons simultaneously for 3 seconds
and release.
STEP 2I7
STEP 2I7 Regeneration Time: Set the clock to the hour the regeneration should occur by using
the UP or DOWN buttons. An arrow points to PM after 12. Press SET HOUR to go to STEP 3I7.
STEP 3I7
STEP 3I7 Current Day of Week: Set the current day of the
Display Day of Week
week by using the UP or DOWN buttons (See chart at right
for date codes). Press SET HOUR to go to STEP 4I7. d1 Sunday
d2 Monday
d3 Tuesday
STEP 4I7 d4 Wednesday
STEP 4I7 Sunday Regeneration: To regenerate on Sunday d5 Thursday
use the UP or DOWN button until the arrow points to Regen. d6 Friday
If the arrow does not point to Regen a regeneration will not
d7 Saturday
occur on Sunday. Press SET HOUR to go to STEP 5I7.
STEP 5I7 STEP 5I7 Monday Regeneration: To regenerate on Monday use the UP or DOWN button until
the arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur on
Monday. Press SET HOUR to go to STEP 6I7.
WS1TC & WS1.25 TC Manual Programming Page 4
STEP 6I7 STEP 6I7 Tuesday Regeneration: To regenerate on Tuesday use the UP or DOWN button until
the arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur on
Tuesday. Press SET HOUR to go to STEP 7I7.
STEP 7I7 STEP 7I7 Wednesday Regeneration: To regenerate on Wednesday use the UP or DOWN button
until the arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur
on Wednesday. Press SET HOUR to go to STEP 8I7.
STEP 8I7 STEP 8I7 Thursday Regeneration: To regenerate on Thursday use the UP or DOWN button
until the arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur
on Thursday. Press SET HOUR to go to STEP 9I7.
STEP 9I7
STEP 9I7 Friday Regeneration: To regenerate on Friday use the UP or DOWN button until
the arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur on
Friday. Press SET HOUR to go to STEP 10I7.
STEP 10I7 STEP 10I7 Saturday Regeneration: To regenerate on Saturday use the UP or DOWN button
until the arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur
on Saturday. Press SET HOUR to exit Installer Displays & Settings.
NOTE: If all arrows are turned off in d1-d7, Days to Regen in the User Displays will always read
7 and a regeneration will never occur.
Return to
Normal Mode
User Displays
General Operation
When the system is operating one of two displays will be shown. Pressing UP or DOWN button will
alternate between the displays. One of the displays is always the current time of day (to the nearest
hour). The second display is the days remaining until the next regeneration. If the days remaining
or
is equal to one, a regeneration will occur at the next preset regeneration time. The user can scroll
between displays as desired.
If the system has called for a regeneration that will occur at the preset time of regeneration, the arrow
will point to Regen.
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a time with
low water usage is when a household is asleep. If there is a demand for water when the system is
regenerating, untreated water will be used.
When the system begins to regenerate, the display will change to indicate the cycle of the
regeneration process (see Table 3) that is occurring and an arrow will also point to Regen. The
system will run through the steps automatically and will reset itself to provide treated water when
the regeneration is completed.
Programming Page 5 WS1TC & WS1.25 TC Manual
To initiate a manual regeneration at the preset delayed regeneration time, simultaneously press UP
+ DOWN buttons together and release. The arrow will point to the word Regen if a regeneration is
expected tonight. To cancel the regeneration simultaneously press UP + DOWN buttons and release.
To initiate a manual regeneration immediately, simultaneously press UP + DOWN buttons together for
three seconds. The system will begin to regenerate immediately. The request cannot be cancelled.
Note: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regenerating.
Set Time of Day
STEP 1U
STEP 1U Press SET HOUR
STEP 2U STEP 2U Current time: Set the clock to the closest hour by using the UP and DOWN button. An
arrow points to PM after 12. After a power outage, the time of day will need to be reset. Press SET
HOUR to exit.
Power Loss
If the power goes out current time of day will need to be reset. If the power goes out while the system is regenerating, the cycle
picks up where it was interrupted when the power returns.
Error Message
If E1, E2 or E3 appears on the display contact the OEM for help. This indicates that the
valve did not function properly.
WS1TC & WS1.25 TC Manual Drawings and Part Numbers Page 1
* Drawing number parts 2 through 6 may be purchased as a complete assembly, part V3002.
6
5
3
Drawings and Part Numbers Page 2a WS1TC & WS1.25 TC Manual
WS1TC Drive Cap Assembly, Downflow Piston, Regenerant Piston and Spacer Stack Assembly
4b
Black Plug
4a
4 7
8
6
WS1TC & WS1.25 TC Manual Drawings and Part Numbers Page 2b
WS1.25TC Drive Cap Assembly, Downflow Piston, Regenerant Piston and Spacer Stack Assembly
*Grey Ring
*Grey Distributor
O-ring retainer
2
4
8
2
Spacer Color:
Grey
1.25"
4D
Black Plug
1.25"
Spacer Color:
Black
1.5"
Grey Plug
1.5"
Spacer Color:
Black
1.5"
Grey Plug
Grey Ring
1.5"
Grey
Distributor
O-ring
Retainer
WS1TC & WS1.25 TC Manual
WS1TC & WS1.25 TC Manual
FOR INFORMATION COMMON TO ALL 1 & 1.25 CONTROL VALVES REFER TO THE WS1&WS1.25 COMMON
INFORMATION MANUAL
The common manual contains the Table of Contents shown below
Other Drawings and Part Numbers
Compliance Table No page number
Injector Cap, Injector Screen, Injector, Plug and O-ring Drawings and Part Numbers 3a
Injector Order Information Drawings and Part Numbers 3b
Injector Graphs US Units: Injector Draw, Slow Rinse and Total Flow Rates Drawings and Part Numbers 3c-3d
Injector Graphs Metric Units: Injector Draw, Slow Rinse and Total Flow Rates Drawings and Part Numbers 3e-3f
Refill Flow Control Assembly and Refill Port Plug Drawings and Part Numbers 4
Drain Line 3/4 Drawings and Part Numbers 5
Drain Line 1 Drawings and Part Numbers 6
Water Meter, Meter Plug and Mixing Valve Drawings and Part Numbers 7
Installation Fitting Assemblies Drawings and Part Numbers 8a 8b
Bypass Valve Drawings and Part Numbers 9
Flow Diagrams Service and Backwash Drawings and Part Numbers 10
Flow Diagrams Downflow and Upflow Drawings and Part Numbers 11
Flow Diagrams Rinse and Fill Drawings and Part Numbers 12
WS1 Service Spanner Wrench Drawings and Part Numbers 13
General Information General Information 1
General Warnings (Must appear in OEMs manual) General Information 1
Specifications which must be included in OEMs Manual General Information 2
Quick Reference Specifications General Information 2
Drive Assembly General Information 3
Drive Cap Assembly, Main Piston and Regenerant Piston General Information 3
Spacer Stack Assembly General Information 4
Injector Cap, Screen, Injector Plug and Injector General Information 4
Refill Flow Control Assembly or Refill Port Plug General Information 4
Drain Line Flow Control and Fitting Assembly General Information 5
Water Meter or Meter Plug General Information 6
Mixing Valve General Information 6
Installation Fitting Assemblies General Information 6
Bypass Valve General Information 7 - 8
Installation Installation 1 - 2
Service Instructions Service Instructions 1 - 5
Troubleshooting Troubleshooting 1 - 2
Limited Warranty Last Page