Fast start-up 2 min from hot standby to full number of starts, stops or trips
plant load Full plant output at high altitudes and in hot and
Combined heat and power as an option dry ambient conditions
Excellent plant availability and reduced need for Minimal water consumption due to closed-circuit
back-up capacity due to multi-unit installation radiator cooling
High part-load efficiency Stepwise investment with smaller risks and
Low gas pressure requirement optimized profit generation.
2
ICE-strengths: Relatively high efficiency at small
scale; modular; rapid start-up; lower capital cost
than OCGT; tolerant of different fuel qualities
Source:
Internal Energy Agency: Energy Technology Perspective Harnessing Electricitys Potential, 2014
Whether you need baseload, intermediate, perfect control over daily load fluctuations.
peaking or standby power generation, we And as energy demand grows, the high
provide it. WRTSIL gas and multi- modularity of our products makes it easy to
fuel plants are typically based on modular expand your power plant to meet any future
419MW internal combustion engine (ICE) changes. You can upgrade your plant at any
units. ICEs are designed for continuous time without risking operational reliability. After
operation on natural gas or in multi-fuel mode all, several smaller units are, by definition,
(gas/oil). always more reliable than one large one.
Our gas and multi-fuel power plants offer Incremental investment also ensures continual
high output and efficiency even in the most competitiveness in todays volatile market.So,
challenging conditions and locations. In the just pay for what you need, when you need it.
hottest deserts or high in the mountains, in city Finally, our technologies are backed up
centres or jungles, energy output and efficiency by world-wide operations and management
is consistent and reliable, throughout the services that ensure efficiency and optimize
entire load range. And the fact that a negligible equipment reliability throughout its lifecycle.
amount of water is consumed in the process We offer true flexibility, both in fuel choice
has obvious advantages, too, particularly in dry and in our ability to respond to operational
locations. demand, and this makes Wrtsil gas and
World-class operational flexibility with multi-fuel power plants the solid choice in
uniquely fast starts, stops and restarts, ensures todays power market.
3
LIFETIME COMMITMENT
Count on our total commitment and Wrtsil carries out deliveries ranging number of Operations & Management (O&M)
comprehensive range of services from equipment supply, or equipment and customers stands as proof.
tailored to your requirements to engineering; to complete turnkey projects Wrtsil currently operates around 500 marine
achieve the best possible performance that include engineering, procurement and and land-based installations around the world.
from your power plant investment construction. Our development and finance If you choose to operate the plant yourself,
throughout its lifecycle. group, together with a comprehensive you can still rest assured that you have
service network, make for a complete project the best possible support available when
implementation, from concept and financing to and where you need it from training and
construction and beyond. online support to service packages or plant
Our range of services covers everything modernization and upgrading. Our global
from rapid spare parts delivery to complete network of 11,000 professionals worldwide
operations and maintenance solutions. By stands ready to provide you with the support
optimizing all aspects of the power plants you need, anywhere at any time.This ensures
operations and minimizing the economic and that your power plant will operate at its highest
technological risks involved, we enhance the efficiency and performance levels throughout
plants profitability. Our continuously growing its lifetime.
4
We have a track record of providing over 56 GW of power in over 170 countries.
Here are just a few examples.
Control room
6
A Wrtsil GasCube plant is a multiple of engine modules designed to meet a
QUISQUEYA I & II, DOMINICAN REPUBLIC
total power need of 630 MW. A GasCube based on the Wrtsil 16V34SG or
Customer........................................ Barrick & EGE Haina (Industrial & Utility)
Type.................................................. Flexicycle 50DF multi-fuel power plant Wrtsil 20V34SG, with all the auxiliaries and components needed to make up
Operating mode................................................................ Flexible baseload a working power production unit, provides 710MWe per unit. Due to the self
Gensets.............................................................12+12 x Wrtsil 18V50DF contained design, the GasCube is the optimal solution for agile, streamlined and
Total output...................................................................................430 MW exceptionally cost efficient project execution.
Fuel............................................................................... Natural gas & HFO High electrical efficiency
Scope..................................EPC (Engineering, Procurement & Construction) Minimization of the plants own electricity consumption
Delivered........................................................................................... 2013 Simple and reliable technical solutions
Compact, pre-engineered plant design
Perfect for EPC deliveries even to areas lacking infrastructure.
mechanical auxiliary systems including the date. In CHP applications for hot water production The engine cooling arrangement using closed-
fuel system, lubrication, air intake, cooling, the total efficiency can reach 95%. This lowers circuit radiator cooling reduces plant process
exhaust processing and sound-proofing the production cost of electricity and increases water consumption to almost zero, minimizing
electrical systems the economic attraction of these plants. the effect on local water resources.
automation The environmental impact of a Wrtsil The hall design and low building profile
heat recovery system in combined heat and gas or multi-fuel plant is low. NOX emission help the plant to blend in with its surroundings.
power plants levels fulfill the majority of global emission Effective sound-proofing allows the plant to
civil works and structures. requirements today without any secondary be operated even in densely populated areas,
Installing a steam boiler to drive a steam turbine cleaning methods. To further reduce where the actual loads are, which effectively
will increase the power production by close environmental impact, effective oxidation prevents possible transmission and distribution
to 10%. The steam cycle option can either be and/or NOX catalysts and other advanced bottlenecks.
included in the initial design, or added at a later equipment can be installed.
7
FLEXIBILITY IN OPERATION
IPP3, JORDAN
Customer..................................................... NEPCO (IPP)
Type......................... Wrtsil 50DF multi-fuel power plant
Operating mode.................. Flexible baseload & peak load
Gensets........................................ 38 x Wrtsil 18V50DF
Total output....................................................... 573 MW
Fuel............................................ Natural gas, HFO & LFO
Scope..............................................EPC in a Consortium
Delivered................................................................ 2014
An ICE is todays most efficient means Wrtsil gas engines operate on most natural conversion possibilities create a good base for
of converting liquid or gaseous fuels into gas types. They are also available as multi- investments in gas infrastructure.
energy. Wrtsil gas power plants can run fuel engines, operating on natural gas as Wrtsil gas engines with modern lean-burn
on low-pressure gas. The multi-fuel option well as on diesel fuel. When the gas supply is technology reach over 50% electrical efficiency.
gives even more flexibility when the gas uncertain or prices are volatile, it is possible The heat recovery option does not affect the
supply is unreliable. to switch over from gas to diesel or vice versa electrical efficiency of the generating set. High
during continuous operation if necessary. The efficiency translates into considerable savings in
option to run on diesel as a backup fuel can fuel costs compared to other technologies.
considerably improve reliability in case of gas Multi-unit configuration creates a part-load
shortages. profile that enables you to optimize the entire
In emerging gas markets it is possible to output range of the plant. For a given total plant
build a fast track plant operating on liquid load, you simply operate as many individual
fuel, and later expand and convert the plant to generating sets as required at their optimal
operate on gas as the supply becomes more efficiency.
readily available. This also works the other Wrtsil gas and multi-fuel power plants
way around: existing power plants with gas withstand extreme conditions, with only
8
1.05
Derating due to cooling water temperature. Wrtsil gas combustion
(Derating due to inlet air temperature starts at 45 C)
1 engines offer stable
Wrtsil 20V34SG
(radiator cooling)
output and high
Derating factor
0.95 performance in hot
and dry conditions. No
Aeroderivate gas turbine water consumed for
0.9
plant cooling = arid area
Industrial gas turbine
suitability!
0.85
0.8
15 20 25 30 35 40 45
Ambient temperature (C)
1.1
1.05 Wrtsil 20V34SG Wrtsil gas ICEs offer
(radiator cooling) stable output and high
1
performance at high
0.95
Derating factor
altitudes as well.
0.9
0.85
Industrial gas turbine
0.8
Aeroderivate gas turbine
0.75
0.7
0.65
0 500 1000 1500 2000 2500 3000
Altitude [m]
9
FLEXIBILITY IN FUEL DUAL-FUEL ENGINES (DF)
The dual-fuel engine utilizes a lean-burn
combustion process when operating on gas.
LEAN-BURN GAS ENGINES (SG) Here, the gas is mixed with air before the
The engine generating sets used in The SG engines are spark-ignited lean-burn intake valves during the air intake period. After
Wrtsil power plants are driven by engines. In this process, the gas is mixed the compression phase, the gas-air mixture
heavy-duty medium-speed four-stroke with air before the inlet valves. During the is ignited by a small amount of liquid pilot
ICEs. These generating sets consist of an intake period, gas is also fed into a small fuel. After the working phase the exhaust gas
engine connected directly to a generator prechamber, where the gas mixture is rich valves open and the cylinder is emptied of
via a flexible coupling. The generator and compared to the gas in the cylinder. At the end exhaust gases. The inlet air valves open when
engine are rigidly mounted on a common of the compression phase the gas-air mixture the exhaust gas valves close, and the process
baseframe. in the prechamber is ignited by a spark plug. starts again.
The flames from the nozzle of the prechamber The dual-fuel engine is also equipped with
ignite the gas-air mixture in the whole cylinder. a back-up fuel system. This is a normal diesel
Combustion is fast. After the working phase the process with camshaft-operated liquid fuel
cylinder is emptied of exhaust and the process pumps running parallel to the process and
starts again. working as a stand-by.
SG PRINCIPLE DF PRINCIPLE
Liquid fuel
Gas
Inlet Inlet
Compression Compression
Combustion Combustion
Outlet Outlet
Wrtsil 18V50SG
The worlds largest gas-fired ICE
The worlds most efficient single cycle prime
mover
10
GAS-DIESEL ENGINES (GD) GAS GENSETS
The GD engine utilizes the diesel combustion process in all operational Wrtsil 50SG 18V50SG
modes. In gas mode, the gas is injected at high pressure after the pilot Power, electrical (50 Hz/500 rpm) kW 18 320
fuel and is ignited by the flame from the pilot fuel injection. The amount
Power, electrical (60 Hz/514 rpm) kW 18 760
of pilot fuel is equivalent to approximately 5% of the fuel energy input at
Genset dry weight (tonne) 5% 365
full engine load.
The gas-diesel engine can be switched over instantly to liquid fuel Reduced transport weight (tonne) 5% 293
mode operation. The liquid fuel can be light fuel oil, heavy fuel oil or Wrtsil 34SG 9L34SG 16V34SG 20V34SG
crude oil. In this case, the process is the same as the conventional diesel
Power, electrical (50 Hz/750 rpm) kW 4340 7740 9730
process.
Power, electrical (60 Hz/720 rpm) kW 4170 7430 9340
In fuel sharing mode, the ratio between liquid and gas fuel amounts
can be controlled and varied during operation. The operating window for Genset dry weight (tonne) 5% 77 120 130
the fuel sharing mode is 30 to 100% load and the gas/liquid fuel ratio
can vary according to the fuel sharing window. MULTI-FUEL GENSETS
The gas-diesel process can tolerate big variations in the gas quality Wrtsil 50DF 18V50DF
and is especially suitable for non-pipeline quality gas, such as Power, electrical (50 Hz/500 rpm) kW 16640
associated gas in oil fields.
Power, electrical (60 Hz/514 rpm) kW 17080
11
Wrtsil is a global leader in complete lifecycle power solutions for the
marine and energy markets. By emphasising technological innovation
and total efficiency, Wrtsil maximises the environmental and economic
performance of the vessels and power plants of its customers. Wrtsil