Вы находитесь на странице: 1из 4

X-Over

Available in a variety of connection types, sizes, and ODs


APPLICATIONS The standard makeup length for a box-by-pin x-over is
Standard coiled tubing interventions 6 in, and the standard makeup length for a box-by-box
HPHT operations x-over is 8 in. The ID of all x-overs is the same as
the smallest thread on the part.
Sweet and sour wells per NACE

ADVANTAGES
Standard lengths
Premium materials
Standard oilfield tool joint threads
350 degF [177 degC] temperature rating

X-over.

Specifications
Part Number OD, ID, Upper Thread Lower Thread Will Pass Makeup Service Working Tensile Torque Capacity,
in [mm] in [mm] Ball Size, Length, NACE Pressure, psi Strength, ft.lbf [daN.m]
in [mm] in [mm] [kPa] lbf [daN]
1-in AMMT-S Box
100598123 1.50 0.687 1-in AMMT-S 3
4-in CS Hydril 0.625 6.0 Yes 10,000 22,500 417
[38.10] [17.45] Box Pin [15.88] [152.40] [68,948] [10,008] [56.53]
100598141 1.69 0.812 1-in AMMT-S 1.50-in DS 0.75 6.0 Yes 10,000 21,702 396
[42.93] [20.62] Box Pin [19.05] [152.40] [68,948] [9,653] [53.69]
100598167 1.69 0.812 1-in AMMT-S 1-in CS Hydril 0.75 6.0 Yes 10,000 31,790 374
[42.93] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [50.70]
100598277 1.69 0.812 1-in AMMT-S 1-in AMMT-S 0.75 8.0 Yes 10,000 31,790 374
[42.93] [20.62] Box Box [19.05] [203.20] [68,948] [14,141] [50.70]
100598574 1.75 0.812 1-in AMMT-S 1.50-in DS 0.75 6.0 Yes 10,000 21,702 396
[44.45] [20.62] Box Pin [19.05] [152.40] [68,948] [9,653] [53.69]
100598599 1.75 0.812 1-in AMMT-S 1-in CS Hydril 0.75 6.0 Yes 10,000 31,790 604
[44.45] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100598612 2.13 0.812 1-in AMMT-S 1.812-in DS 0.75 6.0 Yes 10,000 31,790 604
[54.10] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100598671 2.13 0.812 1-in AMMT-S 112-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[54.10] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
X-Over
Specifications
Part Number OD, ID, Upper Thread Lower Thread Will Pass Makeup Service Working Tensile Torque Capacity,
in [mm] in [mm] Ball Size, Length, NACE Pressure, psi Strength, ft.lbf [daN.m]
in [mm] in [mm] [kPa] lbf [daN]
11/2-in AMMT-S Box
100599018 2.0 0.812 1 2-in AMMT-S
1
1-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[50.80] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100599016 2.0 0.937 11/2-in AMMT-S 1.50-in DS Pin 0.875 6.0 Yes 10,000 21,702 396
[50.80] [23.80] Box [22.23] [152.40] [68,948] [9,653] [53.69]
100599038 2.0 1.03 11/2-in AMMT-S 11/4-in CS Hydril 1.0 6.0 Yes 10,000 58,788 1,568
[50.80] [26.16] Box Pin [25.4] [152.40] [68,948] [26,150] [212.59]
100599087 2.13 0.812 11/2-in AMMT-S 1-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[54.10] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100599091 2.13 1.03 11/2-in AMMT-S 1.812-in DS 1.0 6.0 Yes 10,000 52,229 1,154
[54.10] [26.16] Box Pin [25.4] [152.40] [68,948] [23,233] [156.46]
100599064 2.13 1.03 11/2-in AMMT-S 11/4-in CS Hydril 1.0 6.0 Yes 10,000 58,788 1,568
[54.10] [26.16] Box Pin [25.4] [152.40] [68,948] [26,150] [212.59]
100599084 2.13 1.03 11/2-in AMMT-S 11/2-in AMMT-S 1.0 8.0 Yes 10,000 63,772 1,568
[54.10] [26.16] Box Box [25.4] 203.20 [68,948] [28,367] [212.59]
100599109 2.88 1.03 11/2-in AMMT-S 238-in PAC-DSI 1.0 6.0 Yes 10,000 63,772 1,568
[73.15] [26.16] Box Pin [25.4] [152.40] [68,948] [28,367] [212.59]
238-in PAC-DSI Box
100599148 2.88 1.03 238-in PAC-DSI 11/2-in AMMT-S 1.0 6.0 Yes 10,000 63,772 1,568
[73.15] [26.16] Box Pin [25.4] [152.40] [68,948] [28,367] [212.59]
100599282 2.88 0.812 238-in PAC-DSI 1-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[73.15] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100599543 2.88 1.25 238-in PAC-DSI 1.812-in DS 1.125 6.0 Yes 10,000 52,229 1,154
[73.15] [31.75] Box Pin [28.58] [152.40] [68,948] [23,233] [156.46]
100599545 2.88 1.38 238-in PAC-DSI 2.06-in DS 1.25 6.0 Yes 10,000 77,248 2,229
[73.15] [35.05] Box Pin [31.75] [152.40] [68,948] [34,362] [302.21]
100599556 2.88 1.38 238-in PAC-DSI 238-in PAC-DSI 1.25 8.0 Yes 10,000 122,313 4,021
[73.15] [35.05] Box Box [31.75] [203.20] [68,948] [54,407] [545.17]
100599558 3.06 1.38 238-in PAC-DSI 238-in API REG 1.25 6.0 Yes 10,000 122,313 4,021
[77.72] [35.05] Box Pin [31.75] [152.40] [68,948] [54,407] [545.17]
100599560 3.13 1.38 238-in PAC-DSI 238-in API REG 1.25 6.0 Yes 10,000 122,313 4,021
[79.50] [35.05] Box Pin [31.75] [152.40] [68,948] [54,407] [545.17]
100644698 3.13 1.0 238-in API REG 238-in PAC-DSI 1.25 6.0 Yes 10,000 122,313 4,021
[79.50] [25.40] Box Pin [31.75] [152.40] [68,948] [54,407] [545.17]
100644712 3.13 1.0 238-in API REG 238-in PAC-DSI 1.25 9.0 Yes 10,000 122,313 4,021
[79.50] [25.40] Box Box [31.75] [228.60] [68,948] [54,407] [545.17]

1.50-in DS Box
100600837 1.69 0.812 1.50-in DS 1-in AMMT-S 0.75 6.0 Yes 10,000 21,702 396
[42.93] [20.62] Box Pin [19.05] [152.40] [68,948] [9,653] [53.69]
100600841 2.13 0.937 1.50-in DS 11/2-in AMMT-S 0.875 6.0 Yes 10,000 21,702 396
[54.10] [23.80] Box Pin [22.23] [152.40] [68,948] [9,653] [53.69]
100600843 2.13 0.937 1.50-in DS 1.812-in DS 0.875 6.0 Yes 10,000 21,702 396
[54.10] [23.80] Box Pin [22.23] [152.40] [68,948] [9,653] [53.69]
X-Over
Specifications
Part Number OD, ID, Upper Thread Lower Thread Will Pass Makeup Service Working Tensile Torque Capacity,
in [mm] in [mm] Ball Size, Length, NACE Pressure, psi Strength, ft.lbf [daN.m]
in [mm] in [mm] [kPa] lbf [daN]
1.812-in DS Box
100600844 2.13 0.812 1.812-in DS 1-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[54.10] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100600845 2.13 1.03 1.812-in DS 112-in AMMT-S 1.0 6.0 Yes 10,000 52,229 1,154
[54.10] [26.16] Box Pin [25.4] [152.40] [68,948] [23,233] [131.00]
100578996 2.13 1.03 1.812-in DS 112-in AMMT-S 1.0 8.0 Yes 10,000 52,229 1,154
[54.10] [26.16] Box Box [25.4] [203.20] [68,948] [23,233] [131.00]
100600980 2.88 1.25 1.812-in DS 238-in PAC-DSI 1.125 6.0 Yes 10,000 52,229 1,154
[73.15] [31.75] Box Pin [28.58] [152.40] [68,948] [23,233] [131.00]
100600981 2.13 0.937 1.812-in DS 1.50-in DS 0.875 6.0 Yes 10,000 21,702 396
[54.10] [23.80] Box Pin [22.23] [152.40] [68,948] [9,653] [53.69]
2.062-in DS Box
100600982 2.88 1.5 2.06-in DS 238-in PAC-DSI 1.25 6.0 Yes 10,000 77,248 2,229
[73.15] [38.10] Box Pin [31.75] [152.40] [68,948] [34,362] [253.01]
CS Hydril Box
100601490 1.5 0.687 3
4-in CS HYDRIL 1-in AMMT-S 0.625 6.0 Yes 10,000 22,500 417
[38.10] [17.45] Box Pin [15.875] [152.40] [68,948] [10,008] [56.54]
100601491 1.69 0.812 1-in CS HYDRIL 1-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[42.93] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100601495 1.75 0.812 1-in CS HYDRIL 1-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[44.45] [20.62] Box Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100601497 2.0 1.03 114-in CS HYDRIL Box 112-in AMMT-S 1.0 6.0 Yes 10,000 58,788 1,568
[50.80] [26.16] Pin [25.4] [152.40] [68,948] [26,150] [212.59]
100601500 2.13 1.03 1 4-in CS HYDRIL Box 112-in AMMT-S
1
1.0 6.0 Yes 10,000 58,788 1,568
[54.10] [26.16] Pin [25.4] [152.40] [68,948] [26,150] [212.59]
Treating Adapters
100198958 3.06 0.812 2.0 WECO 1-in AMMT-S 0.75 8.0 Yes 10,000 31,790 604
[77.72] [20.62] Female Box [19.05] [203.20] [68,948] [14,141] [81.89]
100318276 3.06 0.812 2.0 WECO 1-in AMMT-S 0.75 6.0 Yes 10,000 31,790 604
[77.72] [20.62] Female Pin [19.05] [152.40] [68,948] [14,141] [81.89]
100602206 3.06 1.03 2.0 WECO 112-in AMMT-S 1.0 8.0 Yes 10,000 63,772 1,568
[77.72] [26.16] Female Box [25.4] [203.20] [68,948] [28,367] [212.59]
100318278 3.06 1.03 2.0 WECO 112-in AMMT-S 1.0 6.0 Yes 10,000 63,772 1,568
[77.72] [26.16] Female Pin [25.4] [152.40] [68,948] [28,367] [212.59]
100198415 3.06 1.375 2.0 WECO 238-in PAC-DSI 1.25 8.0 Yes 10,000 122,313 4,021
[77.72] [34.93] Female Box [31.75] [203.20] [68,948] [54,407] [545.17]
100124657 3.06 1.38 2.0 WECO 238-in PAC-DSI 1.25 6.0 Yes 10,000 122,313 4,021
[77.72] [35.05] Female Pin [31.75] [152.40] [68,948] [54,407] [545.17]
100318247 3.06 0.937 2.0 WECO 1.50-in DS 0.875 8.0 Yes 10,000 21,702 396
[77.72] [23.80] Female Box [22.225] [203.20] [68,948] [9,653] [53.69]
100318275 3.06 0.937 2.0 WECO 1.50-in DS 0.875 6.0 Yes 10,000 21,702 396
[77.72] [23.80] Female Pin [22.225] [152.40] [68,948] [9,653] [53.69]
X-Over
Specifications
Part Number OD, ID, Upper Thread Lower Thread Will Pass Makeup Service Working Tensile Torque Capacity,
in [mm] in [mm] Ball Size, Length, NACE Pressure, psi Strength, ft.lbf [daN.m]
in [mm] in [mm] [kPa] lbf [daN]
Treating Adapters
100173174 3.06 1.25 2.0 WECO 1.812-in DS 1.125 8.0 Yes 10,000 52,229 1,154
[77.72] [31.75] Female Box [28.575] [203.20] [68,948] [23,233] [131.00]
100602207 3.06 1.25 2.0 WECO 1.812-in DS 1.125 6.0 Yes 10,000 52,229 1,154
[77.72] [31.75] Female Pin [28.575] [152.40] [68,948] [23,233] [131.00]
100602208 3.06 1.38 2.0 WECO 2.062-in DS 1.25 8.0 Yes 10,000 77,248 2,229
[77.72] [35.05] Female Box [31.75] [203.20] [68,948] [34,362] [253.01]
100602209 3.06 1.38 2.0 WECO 2.062-in DS 1.25 6.0 Yes 10,000 77,248 2,229
[77.72] [35.05] Female Pin [31.75] [152.40] [68,948] [34,362] [253.01]
Values are based on 80,000 lbf/in2 strength steel at 70 degF [21 degC] and a single-load case. At temperatures above 250 degF [121 degC], ratings are reduced by 10%; at 350 degF [177 degC], ratings are reduced by 20%.
Users should determine the actual operating and load parameters for their own applications.

slb.com/CoilTOOLS

*Mark of Schlumberger
Copyright 2014 Schlumberger. All rights reserved. 09-CT-0022