WARNING: This installation manual is for use by

service personnel. Please be aware that the


manufacturer cannot be responsible for breakage
or damage incurred due to improper installation of
this lens or use of the projector.
1 2
Installation Manual Loosen the lamp replacement Remove the mounting screws of
When replacing the lens, please have the lens replaced by
the store of purchase or a Sharp Engineering certified 1) that fastens the lamp
screw (1 the top cover.
service workshop. The inside of the projector contains high-
AN-PH10EX voltage parts that can be extremely dangerous. Never unit cover, and remove the lamp
attempt to replace the lens by yourself.

AN-PH20EZ Always make sure to turn off the main power and unplug
the power cord before replacing the lens.
unit cover by sliding in the direc-
Be careful not to allow any screws to drop inside the projector tion shown by the arrow (2 2).
AN-PH30EZ while working. This can cause a fire, electrical shock or
malfunction.
Lamp replacement Top cover
AN-PH40EZ Do not attempt to replace the lens while the projector is
suspended from the ceiling. The lens may fall out of the projector
Lamp unit cover screw
resulting in injury.
AN-PH50EZ Before replacing the lens, return the lens shift to the position
2
shown below. (The lens shift is adjusted to the position shown 1
AN-PH60EZ below when shipped from the factory.)
V (vertical) shift: Uppermost position
H (horizontal) shift: Middle position

When replacing the lens, use a commercially available


screwdriver that satisfies all of the conditions indicated below.
Type 2 Philips head screwdriver Mounting screws
Length of protruding section: min. 180 mm (10")
Magnetized

3 4 5 6
1)
Unplug the cable connector (1 Release the tabs while pulling up (When the lens being removed is the AN- Unplug the cable connector.
PH30EZ (XG-PH50X standard lens))
2).
and remove the top cover (2 on the lens cover, and then pull
Remove the lens ring by turning
it out towards you.
in the direction shown by the ar-
row.

1 Cable 2 Cable connector


connector

Tabs

Lens cover
7 8 9 10
Remove the lens mounting Pull out the lens towards you and Remove the lens cap (on the Insert the replacement lens into
screws. 2) by ro-
then take out the lens (2 back) from the replacement lens. the lens mount with the motor
1) in the di-
tating it 90 degrees (1 This explanation uses the example of the section facing up.
rection shown by the arrow. AN-PH10EX.
Lens mount

Lens mounting screws Positioning pin

Motor section
1

2 Lens cap (back)

11 12 13 14
Rotate the replacement lens 90 (When the lens being attached is the AN- Attach the lens cover. Connect the cable connector by
degrees in the direction shown PH30EZ (XG-PH50X standard lens))
Insert the lens cover while spreading apart following steps 1 through 3, and
1), align the posi-
by the arrow (1 Attach the lens ring. the ring section (made of rubber), and then then attach the top cover and
tioning pin with the guide hole Align the a mark on the lens ring with the attach the tabs to the ribs.
positioning pin on the lens (silver pin), in- lamp unit cover.
2), tighten the lens mounting
(2
screws and then connect the sert the lens ring all the way to the back The power of the projector will not come
and then rotate in the direction of the ar- on unless the lamp unit cover is securely
cable connector (33). row. attached.
3 Cable connector Positioning pin
Guide Ribs
hole
Tabs
1 Positioning pin

2 Printed in China
a mark
Lens cover TINS-B760WJZZ
05P01-CH-NM