Вы находитесь на странице: 1из 10

New Home

Certificate ID: AIMAKZS369

Accreditation Number Assessor Name Organisation Name


VIC/BDAV/10/0183 VOYKAN TODOROVIC MASTERS DESIGN & DRAFTING
Assessor Email Assessor Phone Date of Upload
voykan@mastersdesign.com.au 0400 140 966 Saturday, July 25, 2015
Assessor Reference Number
-

1. OVERVIEW

Star rating

6.2

Dwelling address
6.2
The more stars the more
energy efficient DOUBLE STOREY, 20 WOODLAND MEWS, LANGWARRIN

Postcode

3910

Climate zone

62
2
116.7 MJ/m Thermal performance loads (area adjusted) MJ/m2

Heating Cooling Total


For more information on your dwellings thermal
shell rating see:
www.nathers.gov.au 92.2 24.5 116.7

Floor Area (m2 )

Conditioned Unconditioned Total Garage

Scan the QR code below to view the online certificate 258.3 101.9 397 36.8

NatHERS Accredited Assessors Stamp

https://www.fr5.com.au/QRCodeLanding?PublicId=AIMAKZS369

FirstRate5 v5.1.11 24 March 2014

1 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

2. BUILDING FEATURES

Zones Occupancy Type Conditioning Area (m2 ) Ceiling Fans


GARAGE garage 36.8 0
MUDROOM otherDayCond 5 0
STUDY otherDayCond Heated & Cooled 13.5 0
ENTRY otherDayCond 4.8 0
HALLWAY otherDayCond 18.5 0
LOUNGE living Heated & Cooled 23 0
STAIRWELL otherDayCond 7.4 0
PDR otherDayCond 3.6 0
P'TRY otherDayCond 4.8 0
L'DRY otherDayCond 9.4 0
KITCHEN/LIVING kitchen Heated & Cooled 83.7 0
ENS WC otherNightCond 1.5 0
ENS 1 otherNightCond 10.2 0
BED 1 bedroom Heated & Cooled 16.7 0
WIR 1 otherNightCond 13.5 0
BED 2 bedroom Heated & Cooled 18.1 0
WIR 2 otherNightCond 3.5 0
ENS 2 otherNightCond 4 0
BED 3 bedroom Heated & Cooled 14.2 0
WIR 3 otherNightCond 3.3 0
BATH otherDayCond 9.1 0
WC otherDayCond Heated & Cooled 1.6 0
BED 4 bedroom Heated & Cooled 14.8 0
RUMPUS living Heated & Cooled 52.9 0
LIBRARY otherDayCond Heated & Cooled 24.4 0
WIR 4 otherNightCond 3.4 0

Window Types
Code Glass Type Frame Type U-value SHGC
GGG-05-010a clear/12 air gap/clear Generic 16: Aluminium improved 3.58 0.68
double-glazed

FirstRate5 v5.1.11 24 March 2014

2 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

Windows
Zones Window No. Code Height Width Orientation Shade Weather-strips
STUDY Opening 31 GGG-05-010a 2100 1200 W No Yes
LOUNGE Opening 29 GGG-05-010a 2100 1200 W No Yes
LOUNGE Opening 30 GGG-05-010a 2100 1200 W No Yes
PDR Opening 51 GGG-05-010a 1200 600 N No Yes
L'DRY Opening 42 GGG-05-010a 1200 1600 S No Yes
KITCHEN/LIVING Opening 43 GGG-05-010a 2100 1199 S No Yes
KITCHEN/LIVING Opening 46 GGG-05-010a 2100 1200 S No Yes
KITCHEN/LIVING Opening 47 GGG-05-010a 2400 3600 E No Yes
KITCHEN/LIVING Opening 48 GGG-05-010a 2400 2400 N No Yes
KITCHEN/LIVING Opening 49 GGG-05-010a 2400 3600 E No Yes
KITCHEN/LIVING Opening 50 GGG-05-010a 600 2000 N No Yes
ENS WC Opening 16 GGG-05-010a 500 1200 N No Yes
ENS 1 Opening 17 GGG-05-010a 1800 1200 W No Yes
BED 1 Opening 18 GGG-05-010a 2100 3600 W No Yes
WIR 1 Opening 19 GGG-05-010a 1800 1200 W No Yes
BED 2 Opening 20 GGG-05-010a 1500 1500 S No Yes
BED 2 Opening 21 GGG-05-010a 1500 1500 S No Yes
BED 3 Opening 22 GGG-05-010a 1500 1500 S No Yes
BATH Opening 23 GGG-05-010a 1800 599 S No Yes
BED 4 Opening 24 GGG-05-010a 1400 2000 E No Yes
RUMPUS Opening 26 GGG-05-010a 1400 1999 N No Yes
RUMPUS Opening 27 GGG-05-010a 1400 1999 N No Yes
RUMPUS Opening 28 GGG-05-010a 2100 1499 N No Yes
LIBRARY Opening 25 GGG-05-010a 1400 2400 E No Yes

Roof Window Types


Code Glass Type U-value SHGC
Roof Windows
Zones Roof Window No. Code Area (m2 ) Orientation Outdoor Shade Indoor Shade

Skylights
Zones Skylight No. Type Area (m2 ) Orientation Outdoor Shade Diffuser

FirstRate5 v5.1.11 24 March 2014

3 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

External Wall Types 1

Thickness (mm) Added Bulk


Insulation (R)

1: FR5-DB : Double Brick FR5 Wall


Brickwork: generic extruded clay brick (typical 110
density)
Plaster (cement:sand 1:4) 10
Brickwork: generic extruded clay brick (typical 110
density)

2: FR5-BC : Brick Cavity FR5 Wall


Brickwork: generic extruded clay brick (typical 110
density)
Air gap vertical 31-65 mm (40 nominal) 40
unventilated non-reflective (0.9/0.9; E = 0.82)
Brickwork: generic extruded clay brick (typical 110
density)

4: vt library-VBV : VT BRICK VENEER Custom Wall


Brickwork: generic extruded clay brick (typical 110
density)
Air gap vertical 31-65 mm (40 nominal) 40
unventilated reflective (0.2/0.9; E = 0.20)
Rockwool batt: R2.5 83 2.5
Plasterboard 10

FirstRate5 v5.1.11 24 March 2014

4 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

External Walls
Zone Wall Type Area (m2 ) Orientation
GARAGE 1 : FR5-DB : Double Brick 17.2 S
GARAGE 2 : FR5-BC : Brick Cavity 8.3 E
GARAGE 1 : FR5-DB : Double Brick 15.6 W
STUDY 4 : vt library-VBV : VT BRICK 6.6 W
VENEER
ENTRY 4 : vt library-VBV : VT BRICK 7.2 W
VENEER
ENTRY 4 : vt library-VBV : VT BRICK 3 S
VENEER
LOUNGE 4 : vt library-VBV : VT BRICK 2.8 E
VENEER
LOUNGE 4 : vt library-VBV : VT BRICK 16.8 N
VENEER
LOUNGE 4 : vt library-VBV : VT BRICK 12.3 W
VENEER
STAIRWELL 4 : vt library-VBV : VT BRICK 6.8 N
VENEER
PDR 4 : vt library-VBV : VT BRICK 3.3 N
VENEER
P'TRY 4 : vt library-VBV : VT BRICK 4.4 N
VENEER
L'DRY 4 : vt library-VBV : VT BRICK 6.9 S
VENEER
KITCHEN/LIVING 4 : vt library-VBV : VT BRICK 27 S
VENEER
KITCHEN/LIVING 4 : vt library-VBV : VT BRICK 14 E
VENEER
KITCHEN/LIVING 4 : vt library-VBV : VT BRICK 9.5 N
VENEER
KITCHEN/LIVING 4 : vt library-VBV : VT BRICK 14.9 E
VENEER
KITCHEN/LIVING 4 : vt library-VBV : VT BRICK 14.1 N
VENEER
ENS WC 4 : vt library-VBV : VT BRICK 4.4 N
VENEER
ENS 1 4 : vt library-VBV : VT BRICK 5.7 N
VENEER
ENS 1 4 : vt library-VBV : VT BRICK 7.6 W
VENEER
BED 1 4 : vt library-VBV : VT BRICK 10.7 W
VENEER

FirstRate5 v5.1.11 24 March 2014

5 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

WIR 1 4 : vt library-VBV : VT BRICK 8.6 W


VENEER
WIR 1 4 : vt library-VBV : VT BRICK 10.2 S
VENEER
BED 2 4 : vt library-VBV : VT BRICK 11.6 S
VENEER
BED 3 4 : vt library-VBV : VT BRICK 8.7 S
VENEER
BATH 4 : vt library-VBV : VT BRICK 7.1 S
VENEER
BED 4 4 : vt library-VBV : VT BRICK 8.6 S
VENEER
BED 4 4 : vt library-VBV : VT BRICK 9.2 E
VENEER
RUMPUS 4 : vt library-VBV : VT BRICK 24.8 N
VENEER
LIBRARY 4 : vt library-VBV : VT BRICK 13.7 E
VENEER
LIBRARY 4 : vt library-VBV : VT BRICK 11.7 N
VENEER
WIR 4 4 : vt library-VBV : VT BRICK 4 E
VENEER

Internal Insulated Wall Types

Thickness (mm) Added Bulk


Insulation (R)

1: FR5-Int : Internal Plasterboard Stud Wall FR5 Wall


Plasterboard 10
Wool/polyester batt 80/20: R2.5 113 2.5
Plasterboard 10

Internal Insulated Walls


Adjacent Zones Wall Type Area (m2 )
STUDY & GARAGE 1 : FR5-Int : Internal Plasterboard Stud Wall 14.1
STUDY & MUDROOM 1 : FR5-Int : Internal Plasterboard Stud Wall 9.3
HALLWAY & MUDROOM 1 : FR5-Int : Internal Plasterboard Stud Wall 4.6
HALLWAY & MUDROOM 1 : FR5-Int : Internal Plasterboard Stud Wall 5.6
L'DRY & MUDROOM 1 : FR5-Int : Internal Plasterboard Stud Wall 2.7
L'DRY & GARAGE 1 : FR5-Int : Internal Plasterboard Stud Wall 7.2

FirstRate5 v5.1.11 24 March 2014

6 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

Floors 2
Sub Floor Added Bulk
Zone Construction Area (m2 ) Covering
Ventilation Insulation (R)
GARAGE CSOG: Slab on Ground 17.7 encl 0.0 none
GARAGE CSOG: Slab on Ground 19.2 encl 0.0 none
MUDROOM Timber 5 encl 2.0 floattimber
STUDY Timber 12.8 encl 2.0 Carpet
STUDY Timber 0.8 encl 2.0 Carpet
ENTRY Timber 1.6 encl 2.0 floattimber
ENTRY Timber 3.3 encl 2.0 floattimber
HALLWAY Timber 18.5 encl 2.0 floattimber
LOUNGE Timber 14.5 encl 2.0 Carpet
LOUNGE Timber 8.5 encl 2.0 Carpet
STAIRWELL Timber 7.4 encl 2.0 floattimber
PDR Timber 3.6 encl 2.0 Tiles
P'TRY Timber 4.8 encl 2.0 Tiles
L'DRY Timber 9.4 encl 2.0 Tiles
KITCHEN/LIVING Timber 83.7 encl 2.0 floattimber
ENS WC Timber 1.5 encl 0.0 Tiles
ENS 1 Timber 10.2 encl 0.0 Tiles
BED 1 Timber 16.7 encl 0.0 Carpet
WIR 1 Timber 13.5 encl 2.0 Carpet
BED 2 Timber 11.9 encl 0.0 Carpet
BED 2 Timber 6.1 encl 2.0 Carpet
WIR 2 Timber 3.5 encl 2.0 Carpet
ENS 2 Timber 4 encl 0.0 Tiles
BED 3 Timber 14.2 encl 0.0 Carpet
WIR 3 Timber 3.3 encl 0.0 Carpet
BATH Timber 9.1 encl 0.0 Tiles
WC Timber 1.6 encl 0.0 Tiles
BED 4 Timber 14.8 encl 0.0 Carpet
RUMPUS Timber 52.9 encl 0.0 Carpet
LIBRARY Timber 24.4 encl 0.0 Carpet
WIR 4 Timber 3.4 encl 0.0 Carpet

FirstRate5 v5.1.11 24 March 2014

7 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

Roofs 2
Added Bulk Added Bulk
Zone Code Area (m2 )
Insulation (R) Insulation (R)
Ceiling Roof
GARAGE Disc 19.2 4.0 0.0
STUDY Framed 0.8 4.0 2.0
ENTRY Framed 3.3 4.0 2.0
LOUNGE Framed 8.5 4.0 2.0
ENS WC Disc 1.5 4.0 0.0
ENS 1 Disc 10.2 4.0 0.0
BED 1 Disc 16.7 4.0 0.0
WIR 1 Disc 13.5 4.0 0.0
BED 2 Disc 11.9 4.0 0.0
BED 2 Disc 6.1 4.0 0.0
WIR 2 Disc 3.5 4.0 0.0
ENS 2 Disc 4 4.0 0.0
BED 3 Disc 14.2 4.0 0.0
WIR 3 Disc 3.3 4.0 0.0
BATH Disc 9.1 4.0 0.0
WC Disc 1.6 4.0 0.0
BED 4 Disc 14.8 4.0 0.0
RUMPUS Disc 52.9 4.0 0.0
LIBRARY Disc 24.4 4.0 0.0
WIR 4 Disc 3.4 4.0 0.0

Doors
Zone Area (m2 ) Weather-strips
GARAGE 11 Yes
ENTRY 3.9 Yes

FirstRate5 v5.1.11 24 March 2014

8 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

Air leakage

Zone Exhaust Wall/Ceiling Chimneys Downlights Unflued Gas Heater Flues


Fans Vents Heaters

Sealed Unsealed Sealed Unsealed Sealed Unsealed Sealed Unsealed Sealed Unsealed Sealed Unsealed

GARAGE 0 0 0 0 0 0 0 0 - 0 - 0
MUDROOM 0 0 0 0 0 0 0 0 - 0 - 0
STUDY 0 0 0 0 0 0 0 0 - 0 - 0
ENTRY 0 0 0 0 0 0 0 0 - 0 - 0
HALLWAY 0 0 0 0 0 0 0 0 - 0 - 0
LOUNGE 0 0 0 0 0 0 0 0 - 0 - 0
STAIRWELL 0 0 0 0 0 0 0 0 - 0 - 0
PDR 0 0 0 0 0 0 0 0 - 0 - 0
P'TRY 0 0 0 0 0 0 0 0 - 0 - 0
L'DRY 0 0 0 0 0 0 0 0 - 0 - 0
KITCHEN/LIVING 1 0 0 0 0 0 0 0 - 0 - 0
ENS WC 0 0 0 0 0 0 0 0 - 0 - 0
ENS 1 1 0 0 0 0 0 0 0 - 0 - 0
BED 1 0 0 0 0 0 0 0 0 - 0 - 0
WIR 1 0 0 0 0 0 0 0 0 - 0 - 0
BED 2 0 0 0 0 0 0 0 0 - 0 - 0
WIR 2 0 0 0 0 0 0 0 0 - 0 - 0
ENS 2 1 0 0 0 0 0 0 0 - 0 - 0
BED 3 0 0 0 0 0 0 0 0 - 0 - 0
WIR 3 0 0 0 0 0 0 0 0 - 0 - 0
BATH 0 0 0 0 0 0 0 0 - 0 - 0
WC 1 0 0 0 0 0 0 0 - 0 - 0
BED 4 0 0 0 0 0 0 0 0 - 0 - 0
RUMPUS 0 0 0 0 0 0 0 0 - 0 - 0
LIBRARY 0 0 0 0 0 0 0 0 - 0 - 0
WIR 4 0 0 0 0 0 0 0 0 - 0 - 0
Total 4 0 0 0 0 0 0 0 0 0 0 0

Site Exposure: suburban

Software name and version: FirstRate5: 51011 c

Restrictions on use of this software: FirstRate5 cannot model slab edge insulation.

FirstRate5 v5.1.11 24 March 2014

9 of 10 NatHERS is an initiative of the Commonwealth, States and Territories


New Home
Certificate ID: AIMAKZS369

3. EXPLANATORY NOTES

ABOUT THIS REPORT ENDNOTES

Residential energy ratings address the quality of the building 1. Each airspace within a wall construction has a thermal
fabric i.e. walls, windows, floors and roof/ceilings. Ratings do resistance. This varies based on a number of criteria. Each
not cover the energy or water efficiency of appliances including airspace in this certificate is described using these criteria.
heating and cooling, hot water, dishwashers, ovens, fridges, They are as follows:
TVs etc. or solar panel or water tank requirements. The Orientation (vertical, horizontal, etc); Width; Air movement
efficiency or specification of these items is generally covered (ventilated or non-ventilated); and the Emissivity (e) of the
by other regulations, standards or guidelines. surfaces on either side of the air space. Emissivity ranges
from 0.9 for common non reflective building materials to
0.03 for the shiniest reflective foil products. The figures in
DISCLAIMER brackets in each description (eg 0.2/0.9; E = 0.2) refer firstly
to the emissivity of each of the two vertical surfaces facing
The energy values quoted are for comparison purposes only, into the space (in this case one surface is 0.2, for example
they are not a prediction of actual energy use. an anti glare coated foil, and the other 0.9, a normal building
This rating only applies to the floor plan, construction details, material). The value of E is the effective Emissivity of the air
orientation and climate as submitted and included in the space taking into account the emissivity of the surfaces on
attached certified drawing set. Changes to any of these could either side of the air space.
affect the rating.
2. Ceilings with zones above are described as the floor of
the zone above (see Floors schedule).
CONTACT
Ceilings with a roof or a neighbour above are described as
For more information on the Nationwide House Energy Rating the roof of that zone/area (see Roofs schedule)
Scheme (NatHERS), visit www.nathers.gov.au
For more information on energy efficient design and insulation
visit www.yourhome.gov.au

Project Notes

FirstRate5 v5.1.11 24 March 2014

10 of 10 NatHERS is an initiative of the Commonwealth, States and Territories