CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
SUBFRAMING FASTENER
ANCHORED INTO CENTER
OF METALWRAP CLIP
6" WIDE SELF-ADHERING
FLEXIBLE MEMBRANE OR METAL
CONCEPT SERIES
FLASHING- CONTINUOUS AT ALL
CS-260 PANEL
BASE PANEL VERTICAL JOINTS.
PUNCTURE AT PANEL CLIP THEN
CSC-3 FLUSH
SEAL.
PANEL CLIP
INTERIOR GYPSUM
BASE PANEL
BOARD
METALWRAP BASE PANEL-
MODULE
CONCRETE
CLADDING BASE
FLOOR
DRIP FLASH
NON-CURING BUTYL
SHEATHING BASE SEALANT BETWEEN
DRIP FLASH PRIMARY MEMBRANE
FLASH AND PANEL
CEMENTITIOUS INSULATION
LINER
PROTECTION BOARD
FILL ANY VOIDS
GRADE
OVER 1/4" WITH
LOW-EXPANSION
FOAM
2" RIGID
INSULATION
NOTE:
THESE DETAILS ARE FOR INSTALLATION
DAMPPROOFING OR
AND SEALING OF METALWRAP PANELS
WATERPROOFING
ONLY. FOR INSTALLATION AND SEALING
REQUIRED FOR FACE PANELS SEE CENTRIA FOUNDATION WALL
STANDARD DETAILS FOR THE SPECIFIC
FACE PANEL.
AIR/VAPOR BARRIER
SEALANT
CSC-3 FLUSH
PANEL CLIP
SUBFRAMING FASTENER
ANCHORED INTO CENTER
OF METALWRAP MR-100 RAIL
CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
SEALANT BETWEEN
CONCRETE
PANEL LINER AND
FLOOR
MEMBRANE FLASH
SLAB
CONCEPT SERIES
CS-260 PANEL
TWO-PIECE DEFLECTION
FLASHING UTILIZING
DEFLECTION
EXPOSED FASTENERS TO
EITHER SIDE OF JOINT
TRACK
STEEL STUD
SPACE
EXTEND AIR
BARRIER TO PROVIDE
SHEATHING WATER
PROTECTION
PANEL THRU-FASTENER
PANEL THRU-FASTENER
CONCEPT SERIES
CS-260 PANEL
CSC-3 FLUSH
PANEL CLIP
VAPOR RETARDER
(BY OTHERS AS REQ'D)
METALWRAP INSULATED
BACK-UP PANEL
SUBFRAMING FASTENER
ANCHORED INTO CENTER
OF METALWRAP MR-100 RAIL
CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
WOOD
SUBFRAMING FASTENER SUBSILL
ANCHORED INTO CENTER
OF METALWRAP MR-100 RAIL
AIR/VAPOR BARRIER
SEALANT
CSC-3 FLUSH
PANEL CLIP
CONCEPT SERIES
CS-260 PANEL
STEEL STUD
METALWRAP INSULATED 18 GA. MIN.
BACK-UP PANEL
INTERIOR
112 " SUBFRAMING GYPSUM
AND AIR CAVITY BOARD
NOTE:
THESE DETAILS ARE FOR INSTALLATION AND
SEALING OF METALWRAP PANELS ONLY.
FOR INSTALLATION AND SEALING REQUIRED
FOR FACE PANELS SEE CENTRIA STANDARD
DETAILS FOR THE SPECIFIC FACE PANEL.
AIR/VAPOR BARRIER
SEALANT
CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
SUBFRAMING FASTENER
ANCHORED INTO CENTER
6" WIDE SELF-ADHERING
OF METALWRAP MR-100 RAIL
FLEXIBLE MEMBRANE OR METAL
FLASHING- CONTINUOUS AT ALL
METALWRAP PANEL; PANEL VERTICAL JOINTS ABOVE
FIELD CUT AS REQ'D WINDOW. PUNCTURE AT PANEL CLIP
THEN SEAL.
PRIMARY
CONCEPT SERIES CS-260
MEMBRANE
PANEL AND CSC-3 CLIP
FLASHING FROM
WINDOW
STEEL STUD PERIMETER
18 GA. MIN. TO PANEL LINER
PANEL THRU-FASTENER
WOOD BLOCKING
(BY WINDOW
SEALANT
CONTRACTOR)
(BY OTHERS)
WINDOW
NOTE: SECONDARY
THESE DETAILS ARE FOR SEAL (BY
INSTALLATION AND SEALING OF OTHERS)
METALWRAP PANELS ONLY. FOR
INSTALLATION AND SEALING WINDOW AND
REQUIRED FOR FACE PANELS PANNING (BY
SEE CENTRIA STANDARD DETAILS FOR OTHERS)
THE SPECIFIC FACE PANEL.
WINDOW
SECONDARY
SEAL (BY
OTHERS)
WINDOW AND
PANNING (BY
OTHERS)
CS-260 PANEL
(BY OTHERS)
NOTE:
THESE DETAILS ARE FOR INSTALLATION AND
SEALING OF METALWRAP PANELS ONLY.
FOR INSTALLATION AND SEALING REQUIRED FOR
FACE PANELS SEE CENTRIA STANDARD DETAILS FOR
THE SPECIFIC FACE PANEL
MEMBRANE FLASHING;
CONTINUOUS TO BASE.
3 1/2"
MIN. APPLY A CURING BUTYL
NOTCH PANEL LINER AT SEALANT PLUG NEAR EACH
CORNERS AS SHOWN PANEL END DURING PANEL
SEALANT BETWEEN
PANEL LINER AND
INTERIOR MEMBRANE
CSC-3 FLUSH
PANEL CLIP
STEEL STUD
18 GA. MIN.
12
1 " SUBFRAMING
AND AIR CAVITY
CONCEPT SERIES
CS-260 PANEL
INTERIOR
GYPSUM
BOARD
METALWRAP PANEL;
FIELD CUT AS REQ'D
MINIMUM SEALANT
CONTACT SHOWN
CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
FLASHING TAPE
NOTE: @ VERT. JOINTS
THESE DETAILS ARE FOR INSTALLATION
AND SEALING OF METALWRAP PANELS SEALANT PLUG DETAIL
ONLY. FOR INSTALLATION AND SEALING APPLY SEALANT AS
REQUIRED FOR FACE PANELS SEE CENTRIA PANELS ARE ERECTED.
STANDARD DETAILS FOR THE SPECIFIC
FACE PANEL.
Outside 90 Corner
MR100-07 Dec. 2012
METALWRAP-H w/MR-100
INTERIOR SIDE APPLY A CURING BUTYL
MEMBRANE FLASHING; SEALANT PLUG NEAR EACH
CONTINUOUS TO BASE. PANEL END DURING PANEL
ERECTION.
(PROVIDES A THERMAL
BREAK)
SEALANT BETWEEN
PANEL LINER AND
INTERIOR MEMBRANE
CSC-3 FLUSH
PANEL CLIP
STEEL STUD
18 GA. MIN.
12
1 " SUBFRAMING
AND AIR CAVITY
CONCEPT SERIES
CS-260 PANEL
INTERIOR
(MITERED CORNER) GYPSUM
BOARD
METALWRAP PANEL;
FIELD CUT AS REQ'D
MINIMUM SEALANT
CONTACT SHOWN
CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
CONTINUOUS
INTERIOR SIDE
CORNER
FLASHING
6" WIDE
EXTERIOR SIDE
STEEL STUD
MEMBRANE OR
18 GA. MIN.
METAL FLASHING;
CSC-3 FLUSH CONTINUOUS
PANEL CLIP ONTO BASE
FLASHING BELOW.
" MIN.
3/4" SUBFRAMING
AND AIR CAVITY
INTERIOR
2
METAL CLOSURES 1 GYPSUM
2
BOARD
CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
CONCEPT SERIES 3
8
CS-260 PANEL
" MIN.
METALWRAP PANEL;
FIELD CUT AS REQ'D
NOTE:
THESE DETAILS ARE FOR INSTALLATION FLASHING TAPE
AND SEALING OF METALWRAP PANELS @ VERT. JOINTS.
ONLY. FOR INSTALLATION AND SEALING
REQUIRED FOR FACE PANELS SEE CENTRIA SEALANT PLUG DETAIL
STANDARD DETAILS FOR THE SPECIFIC APPLY SEALANT AS
Inside 90 Corner
MR100-08 Dec. 2012
METALWRAP-H w/MR-100
NOTCH PANEL FACE AT APPLY A CURING BUTYL SEALANT SEALANT BETWEEN
CORNERS AS SHOWN PLUG NEAR EACH PANEL END PANEL LINER AND
CONTINUOUS
INTERIOR SIDE
CORNER
FLASHING
6" WIDE
EXTERIOR SIDE
STEEL STUD
MEMBRANE OR
18 GA. MIN.
METAL FLASHING;
CONTINUOUS
ONTO BASE
CSC-3 FLUSH FLASHING BELOW.
PANEL CLIP
INTERIOR
3/4" SUBFRAMING
AND AIR CAVITY GYPSUM
BOARD
CONTINUOUS MR-100
ATTACHMENT SYSTEM AT EACH
CONCEPT SERIES
CS-260 PANEL
3
8
" MIN.
METALWRAP PANEL;
FIELD CUT AS REQ'D
NOTE:
THESE DETAILS ARE FOR INSTALLATION FLASHING TAPE
AND SEALING OF METALWRAP PANELS @ VERT. JOINTS.
ONLY. FOR INSTALLATION AND SEALING
REQUIRED FOR FACE PANELS SEE CENTRIA SEALANT PLUG DETAIL
STANDARD DETAILS FOR THE SPECIFIC APPLY SEALANT AS
END WALL
FLASH
CONCEPT SERIES
CS-260 PANEL
SEALANT
2 12 "
(BY OTHERS)
METALWRAP PANEL;
FIELD CUT AS REQ'D
JAMB FLASH
CSC-3 FLUSH
PANEL CLIP
MINIMUM SEALANT
METAL CLOSURES CONTACT SHOWN
12
1 " SUBFRAMING
AND AIR CAVITY
3
8
" MIN.
FACE OF ADJACENT
STRUCTURE
NOTE:
FLASHING TAPE
THESE DETAILS ARE FOR INSTALLATION AND
@ VERT. JOINTS
SEALING OF METALWRAP PANELS ONLY.
FOR INSTALLATION AND SEALING REQUIRED FOR
FACE PANELS SEE CENTRIA STANDARD DETAILS FOR SEALANT PLUG DETAIL
THE SPECIFIC FACE PANEL APPLY SEALANT AS
PANELS ARE ERECTED.
End Wall
MR100-09 Dec. 2012
METALWRAP 100 SERIES
STEEL STUD
18 GA. MIN.
INTERIOR SEALANT BETWEEN
GYPSUM PANEL LINER AND
BOARD PRIMARY END WALL
FLASH
END WALL
FLASH
[13]
CONCEPT SERIES
"
CS-260 PANEL
SEALANT 14 "
1
2
CSC-3 FLUSH
PANEL CLIP MINIMUM SEALANT
CONTACT SHOWN
3
FACE OF ADJACENT 8
" MIN.
STRUCTURE
NOTE:
FLASHING TAPE @
THESE DETAILS ARE FOR INSTALLATION AND
VERT. JOINTS
SEALING OF METALWRAP PANELS ONLY.
FOR INSTALLATION AND SEALING REQUIRED FOR
FACE PANELS SEE CENTRIA STANDARD DETAILS FOR SEALANT PLUG DETAIL
THE SPECIFIC FACE PANEL APPLY SEALANT AS
PANELS ARE ERECTED.
3/8" 3/8"
6" MIN.
Butyl Butyl
Sealant Sealant
Continuous Continuous
The Vertical
Joint Sealant
and the Marriage Bead
Vertical Joint
MR100-10 Dec. 2012
METALWRAP-H w/MR-100
A
SIZE OF FLASH VARIES
BY LOCATION & PITCH
OF CLADDING
Seal perimeter
W/Polyurethane Sealant
Electrical Box
Surface-mount on panel
exterior. Shim to adjust
for cladding depth.
(BY ELECTRICAL CONTRACOR)
Interior opening around
conduit penetration to be
NEATLY DRILLED & SEALED
by Electrical installer.
Conduit Stub
(NBC)
NOTE:
THESE DETAILS ARE FOR INSTALLATION Section A-A
AND SEALING OF METALWRAP PANELS
ONLY. FOR INSTALLATION AND SEALING
REQUIRED FOR FACE PANELS SEE CENTRIA
STANDARD DETAILS FOR THE SPECIFIC
FACE PANEL.
STUDS (NBC)
METALWRAP
12
1 " DEEP HATSHAPED
SUBGIRT (SG-150-16)
14
1 " DEEP HATSHAPED
SUBGIRT (SG-125-16)
[13]
"
1 2
HORIZONTAL
1 " 2 PIECE VERTICAL REVEAL
IW-20A 4
FLASHING WITH HEM
[6]
NOTE:
THESE DETAILS ARE FOR INSTALLATION AND
SEALING OF METALWRAP PANELS ONLY.
FOR INSTALLATION AND SEALING REQUIRED FOR
FACE PANELS SEE CENTRIA STANDARD DETAILS FOR
THE SPECIFIC FACE PANEL
STUDS (NBC)
METALWRAP
12
1 " DEEP SUBGIRT
(SG-150-16)
14
1 " DEEP SUBGIRT
(SG-125-16)
" [38]
" [13]
1 "
1 2
4 1
1 2
[6]
2 PIECE VERTICAL REVEAL
EXPOSED FASTENER FLASHING WITH HEM
PANEL PROFILES
NOTE:
THESE DETAILS ARE FOR INSTALLATION AND
SEALING OF METALWRAP PANELS ONLY.
FOR INSTALLATION AND SEALING REQUIRED FOR
FACE PANELS SEE CENTRIA STANDARD DETAILS FOR
THE SPECIFIC FACE PANEL
STUDS (NBC)
METALWRAP
1 1/2" DEEP SUBGIRT
(SG-150-16)
[13]
"
1 2
CONCEPT SERIES
HORIZONTAL PANEL
1 "
[6]
NOTE:
THESE DETAILS ARE FOR INSTALLATION AND
SEALING OF METALWRAP PANELS ONLY.
FOR INSTALLATION AND SEALING REQUIRED FOR
FACE PANELS SEE CENTRIA STANDARD DETAILS FOR
THE SPECIFIC FACE PANEL
STUDS (NBC)
ERECTOR NOTE:
AFSEALTIEHELDAASPDRCONDIREQUIOVIDETREIOED.NN.D DAM
BACK-UP ANEL
METALWRAP
FLSAESLHFINAGDHTEARPIENGBUTYL
PANELFLPROIINMAERWRIYNMDOEMWBPREANREIMFELTAESRHINTOG
FIELD TAB JAMB
JAMB FLASH
WEATHERSEAL(NBC)(TYP.)
NOTE:
THESE DETAILS ARE FOR INSTALLATION
AND SEALING OF METALWRAP PANELS
ONLY. FOR INSTALLATION AND SEALING
REQUIRED FOR FACE PANELS SEE CENTRIA
STANDARD DETAILS FOR THE SPECIFIC
FACE PANEL.
INTERSECTION OF
HEAD, JAMB AND SILL FLASH (ISO) Dec. 2012