Bulletin 34P02A00-71E
http://stardom.biz
Network
Engineering
Integration
Information
Integration
Same Look & Feel as Yokogawa DCS CENTUM Human Machine Interface (HMI) via gateway station
OPC, DNP3, and Modbus support for use with a variety of SCADA systems
Asset management via a variety of digital communications
Network
TCP/IP
based open network configuration
Support
of FOUNDATIONTM fieldbus, HART, ISA100, Modbus, PROFIBUS-DP, and CANopen
Communication using network infrastructure, GPRS, satellite, and more
Reliability
Excellent
environmental resistance
Dualredundant configuration for all key components
ECC memory
Engineering
Support of all five IEC61131-3 programming languages
Extensive regulatory control libraries cultivated in Yokogawa DCS history
Easy to reuse software architecture
Information
Embedded Web server for remote maintenance
E-mail alarm notification from/to controllers
2 Data logging and FTP transmission of log files on controllers
Reliability
takumi "craftsmanship"
The FCN, FCN-RTU, and FCJ STARDOM controllers are designed to function as a platform that
helps you exercise your takumi (craftsmanship) in the achievement of excellent applications that
keep you competitive in a rapidly changing market. This platform brings you the following benefits:
- Increased uptime and reduced inventory through the shared use of reliable, hot swappable modules
- Reduced engineering and maintenance workload thanks to the improved reusability of program components
- Enhanced capability to respond in a timely fashion to rapidly changing market requirements through the
adoption of a flexible software architecture and the use of advanced IT functions
STARDOM controllers help you maximize operational excellence.
Redundant controller
Low-power controller
Low power consumption
-40 to +70 , altitudes up to 3,000 m
Built-in I/O channels, and 3 or 8 open I/O slots
All-in-One controller
Redundant network ports
Built-in I/O channels
3
I N T E G R AT I O N
Providing seamless operation from field to center while enhancing the benefits of
digital communications
The use of STARDOM autonomous controllers is a best practice in geographically distributed SCADA applications.
With a seamless connection to a Yokogawa DCS, all your applications can be viewed in a single window.
FCN/FCJ OPC
Yokogawa DCS HMI server for Windows
HIS Yokogawa SCADA
Yokogawa SCADA
for small plant
rk fail
Unified Gateway Netwo atures
over fe
Station (UGS)
eration
and op
Alarm tions on HIS
integ ra
Power
Monitors
Yokogawa
safety instrumented system
Redundant configuration
4
One fieldspanning hundreds of kilometers
With gas fields, pipelines, and other SCADA applications, field devices are often dispersed over
a very wide area, and the annual cost of regularly checking these devices is prohibitively high. By
making use of remote device diagnostics, Yokogawa's plant asset management system enables a
much more efficient maintenance approach with dramatic reductions in costs.
Other devices Ethernet FA-M3 (driver available), MELSEC (driver available), others (Modbus TCP)
SerialRS-232, RS-422/485 FA-M3 (driver available), MELSEC (driver available),
others (Modbus RTU/ASCII)
Remote
Yokogawa plant information monitoring
management system
Yokogawa plant asset
management system
Other vendors
SCADA
Modem
Field Wireless GSM/GPRS,
Management Station Satellite,
PSTN, xDSL, RF, and more
Optical Fiber Ring and more
Field Wireless
Access Point
Modem
HART
PROFIBUS-DP
Serial
Modbus
FOUNDATION
Fieldbus Wireless
Transmitters
Gas Chromatograph
Modbus CANopen 5
HARDWARE
Rich product line for every application and budget
STARDOM controllers can be flexibly configured for a wide range of PLC/RTU applications.
Select from the following three models based on your budget and application.
Correction
PLC STARDOM
of single-bit errors in RAM prevents unexpected malfunctions. without ECC controllers
Time synchronization
Simple network time protocol (SNTP) enables time synchronization as an SNTP server and client.
Durable Construction
Thrives in harsh environments Robust
-40 to +70 and up to 3,000 m altitude for FCN-RTU* Compliant with EMC standards
-20 to +70 and up to 2,000 m altitude for FCN-RTU* Optional Explosion Protection
0 to +55 and up to 2,000 m altitude for FCN - ATEX Typen
0 to +60 and up to 2,000 m altitude for FCJ - FM/CSA Non-Incendive Class Division
* Depending on the combination of I/O modules Optional G3 coating
Failure-proof
Fanless design with excellent heat dissipation
IC chips, which have a higher failure rate, are not mounted on the base module.
Easy Maintenance
Non-stop operation
Hot swappable CPU module (FCN only) and power supply module
Allprogram copy (APC) synchronizes the control side and stand-by
side CPUs without interfering with control.
Tool
Applications and parameters can be accessed by a new CPU module not required
by just inserting the system card.
Open Network
TCP/IP-based open network technologies Ethernet
Direct connection with PLCs from other vendors
2 extension units
CPU bus
module
Reduces the variety of components that need to be kept in inventory
Power
Simple network redundant configuration supply
module
Two ports for control redundant network embedded on CPU
Resource Configurator:
Environment configuration tool for control applications
Connects control application logical I/O with actual hardware I/O
Configures hardware settings for IP addresses, serial ports, etc.
Registers software license
Logic Designer
Platform independent programming tool
Input Logic Output
Resource Configurator
Hardware configuration tool for linking logical I/O with hardware
Linking of logical I/O to hardware
FCN FCN-RT FCJ With Logic Designer, programming and debugging are platform
independent, and with Resource Configurator logic can be easily
ported to other hardware platforms.
FBD LD ST SFC IL
8 (Function Block Diagram) (Ladder Diagram) (Structured Text) (Sequential Function Chart) (Instruction List)
Design Debug
programming commissioning Operation
Reusable Programming p
Applications programmed with IEC 6113-3 languages are well structured and easily modularized.
The network template function enables the use of advanced copy features that eliminate the need to reenter variables.
In addition to enabling the creation of network templates from your programs, Yokogawa provides a number of network
templates for your convenience.
p
Online Download
Modify your application without interfering with a process.
Download projects
No need to stop a controller to modify a control application
Automatic application synchronization of dual redundant
Controlling
Parameter Saving p p
Control Application Debugging Minimize engineering costs by doing both programming and
debugging on one PC.
Software Wiring p
Wiring Check p p
Software wiring function simulates the input and output Resource Configurator's loop check (wiring check) tool
signals without the actual wiring. This eliminates the allows you to check the status of your wiring without
need for a signal generator and test switches during having to use a calibrator or test switch.
loop check and logic debugging. Confirm the actual input signals for each channel.
Wizard available for easy configuration Manually output signals to I/O modules.
Advanced settings for adjustments to process
IN PID OUT
Wiring
block
Logic Analyzer p p
Extensive Help Files p p p
Logic Analyzer saves you time investigating and Extensive help files for all of your programming
analyzing software malfunctions. questions are included.
Records variables in continuous and cycle modes More than 3,500 pages
Exports the recorded data to text format files From IEC 61131-3 basics to specific information on
Adjusts curve colors and scales/ranges on individual axes the use of each library
Instructions on how to use the engineering tool
11
ENGINEERING
Design Debug
programming commissioning Operation
Both the FCN and FCN-RTU controllers can be assigned to the same application.
Only those applications that will be used need to be assigned to a controller.
Any modifications to an application can be downloaded to selected controllers.
Page Layout p p p
Maintenance p p
CPU and I/O module information as well as system logs can be confirmed on a Web browser, dramatically improving
maintenance efficiency.
Advanced IT functionality
Web server, FTP server, e-mail, file logging Controller InfoWell APPF
Java enabled
Control Java
Co-existence of Java applications and control functions on the same Control
applications Java
applications
applications
Control applications
Java
platform applications applications
NPAS Portfolio
All of Yokogawa's long experience with distributed control systems (CENTUM series) has gone into the development of
the POUs that are included in the new process automation system portfolios (NPAS POUs). These cover a wide range of
functions such as regulatory control, mathematical calculations, and sequencing.
Arithmetic Calculation
NPAS_AI_FREQ Frequency input NPAS_TP_CFL Temperature and pressure correction
NPAS_AI_REAL Real data input NPAS_T_CFL Temperature correction
NPAS_AI_DINT/UDINT DINT/UDINT data analog input NPAS_P_CFL Pressure correction
NPAS_AO_ANLG Standard analog output NPAS_ASTM1 Old JIS-based ASTM correction
NPAS_AO_PCNT Regularized data (%) output NPAS_ASTM2 New JIS-based ASTM correction
NPAS_AO_REAL Real data output One-pole three-position selector switch
NPAS_SW_13
NPAS_AO_DINT/UDINT DINT/UDINT data analog output block
NPAS_DI_STS Status input One-pole nine-position selector switch
NPAS_SW_19
block
I/O Data Processing
NPAS_SUBSW
NPAS_MLD_BT Manual loader with bias tracking NPAS_SUBINT
NPAS_RATIO(_RT) Ratio set (with ratio tracking) NPAS_AI2SW_A/B Dual signal selector type A/B
NPAS_PG_L30(_BP) 30-zone program set (with bumpless) NPAS_AI3SW Analog-input 2-out-of-3 circuit
NPAS_VELLIM(_PB) Velocity limiter (with output pushback) NPAS_SL2SW_A/B High-low range switching type A/B
NPAS_AS_H/M/L Auto-selector High/Medium/Low NPAS_DI3 Digital input 2 out of 3 circuit
NPAS_FOUT Cascade signal distributor NPAS_NPS_STR Totalization Structuralization
NPAS_FFSUM(_BL) Feedforward signal summing (with NPAS_PB6 Six-pushbutton block
balancing) Eight-input resource scheduler typeA/B
NPAS_XLMT_S/D Single/Double cross-limit NPAS_RS8_A
(permission non-holding)
14 NPAS_BSET_F Batch set block for flow measurement Eight-input resource scheduler
NPAS_RS8_B
NPAS_BSET_LW Batch set block for weight measurement (permission holding)
NPAS Features
Straightforward programming for easy maintenance
A variety of input, control calculation, and output processing
POUs prepared for straight forward programming.
Input and output POUs include routines for the processing of
4-20 mA, RTD, mV, FOUNDATION fieldbus, and other types
of input and output signals. Input signal conversion Output signal conversion
PV/CPV overshoot Tight shut/full open
Input and output POUs can be selected based on signal type. Input open alarm check
Integrated control processing in a single POU RB_IN CAS_IN BIN RL1 RL2 TIN TSI INTLOCK
Input, alarm, control calculation, and output processing can all be CASV
CAS (VN) (RLV1) (RLV2) (TSW)
AUT
integrated in individual POUs for smooth linking between functions. MAN SV
RCASV
RCAS MAN
The integration of various types of processing in a single POU CAS/AUT
Input Control Output
simplifies the creation of programs. IN processing PV calculatioins processing MV OUT
ROUT
Individuals POUs can be accessed as a tag by an FCN/FCJ Alarm
RMV
processing
(CASV)
application or SCADA system.
(RB_OUT) Input/Output parameter Access parameter
process
Input / Output parameter
Access parameter
Communication Portfolios
FCN/FCJ controllers communicate with other PLCs and SCADA systems using the following communication portfolios:
Ethernet
Time Synchronization
SNTP server SNTP client
Time is synchronized between the FCJ, FCN, and FCN-RTU
using the simple network time protocol (SNTP).
Note: The FCN-RTU does not support SNTP server functions.
Report
API21.1 compliant Alarm
Logging
16 Up to 100
*1 : OPC Client software can be installed
on the same PC with FCN/FCJ OPC
controllers Server for Windows.
FCN/FCJ
SCADA
Integrated remote control and monitoring of distributed utilities
The use of the FAST/TOOLS supervisory control and data acquisition (SCADA)
system in a client/server configuration enables the integrated remote control
and monitoring of distributed utilities and reduces engineering workload.
Web-based supervision
A Web-based HMI is a cost effective solution that provides anytime / anywhere
access to the information needed to make quick and timely decisions.
The Web-based HMI eliminates the need for client software
installation and maintenance.
Process and product information can be shared across the enterprise on
devices such as a notebook PCs and smartphones.
Web security technology on HMI clients ensures that only authorized
individuals gain access to data and applications.
Val, Time
often used. However, communications can easily
be disrupted and the cost of transferring large
amounts of data is often prohibitive. The use
of FAST/TOOLS with the FCN/FCJ controllers
enables the following:
Report by exception
To hold down communications costs, only
Communication fails Communication recovers
changed data is sent to FAST/TOOLS. Data is missing Data is missing
Network fail-over
With the time stamping of data from the FCN/FCJ controllers, a smooth switch-over with the
recovery of all data is assured in the event of a network failure. 17
I N F O R M AT I O N
Dramatic changes in utility management at remote site
By including advanced IT functions in its industrial use controllers,
Yokogawa has given them an integrated control and information processing capability.
InfoWell allows you to make full use of these IT functions without the need for any special programming skills.
Real-time Real-time bar Real-time trend Table Bar chart Line-segment Messages
numeric box chart chart chart
Logging Portfolio
The application data collected and logged on the controller can be viewed in
either a table or trend chart. Data on the FCN/FCJ controllers can be viewed
either online (via a browser) or offline (by FTP file transfer to a PC).
Periodical FTP tool to a PC is preared. Trend chart Table
Logging & Reporting Function The InfoWell logging portfolio logs data and creates daily, monthly, and yearly reports.
Logging of control application data on controllers
Periodic data logging : High speed (every 1 to 60 seconds) or low speed (every 1 to 60 minutes)
Batch logging : High speed (every 1 to 60 seconds) or low speed (every 1 to 60 minutes)
Snapshot logging : Continuous or trigger SOE logging : 100 msec or longer Message logging : Alarm and event messages
Report file generation
Report type : Daily, monthly, yearly Closing data : Minimum, maximum, average, total
Logging view Logging data can be viewed online using a Web browser or offline using the Logging Viewer.
Data can be displayed in trend or tabular format.
Trend format : Up to 10 pens can be assigned. Tabular format : Up to 40 items can be viewed.
Logging configuration Logging can be configured online or offline using the Logging Configurator tool.
Logging file collection Logging files from multiple controllers can be periodically collected using the Logging File Collector tool.
Image 2
Remote maintenance
Desktop PC Web browser
Monitoring and
operation
Remote monitoring with versatile data display and security
features
Use a Web browser to monitor the status of an application from
a remote location. No need to be in central control room
Intranet /Internet Data display in numeric, tabular, or graphical format
Field Office
Oil&gas
Application Challenges
Wellhead control and monitoring 1. Oil and gas wellheads are located in remote and hazardous areas
2. New control functions and more reliable hardware are required to
increase productivity
3. RTUs must be able to flexibly accommodate changing
requirements over the entire wellhead lifecycle.
4. System software needs to match the workflow (not the other way
around).
Solution
Yokogawa s FCN-RTU controllers and the FAST/TOOLS SCADA package enhance productivity at well sites in the
following ways:
1. At unmanned wells in remote locations, there is no room for compromise in hardware reliability. Failure proof
in design, the STARDOM control system makes use of ECC memory that, for example, can detect and correct
errors caused by exposure to background radiation. The programs running on the hardware are also highly
reliable, and have been prepared using libraries (application portfolios) of control and metering code written in
the five IEC61131-3 programming languages.
2. Gas and oil vary in pressure, temperature, and composition, and the control method and utilities during the
operation years due to well condition changes. Such modifications can be done remotely, without interfering
with site operations.
3. Yokogawa s FAST/TOOLS SCADA has a web-based HMI that can be accessed from mobile devices. Whether
working in a central control room or on site, the workflow processes are the same. The FCN-RTU controller
also is able to keep logs on flow rates and other types of data that can be viewed on a web browser such as
Internet Explorer using embedded web server functions.
FAST/TOOLS
Overview
EEMUA 191 compliant alarm management
Same workflow in central control room / on site
Setting and configuration with Internet Explorer
Dahydration
Well Gas
ESD*1 monitoring/ Pipeline to GOSP
control
InfoWell
EGM*2 ESD
Well Separator control
Tank
Oil Delivery
Separator
ESD
Contaminated water
Metering Control
Well
Overview
Monitoring
Throw
Utility control
Ash
Garbage
FCN-RTU Configuration (CPU redundancy and extension unit are not applicable.)
Long Type Configuration Short Type Configuration
(Redundant Power Supply is enabled)
BASE MODULES FCN : Use with FCN RTU : Use with FCN-RTU
Model Name FCN* RTU* Specification
Base module p p
NFBU200-S0 Weight: 1.9kg
(19-inch rack-mounted) Max current consumption: 0.4 A (5 V) (Self-consumption)
Base module Operation temperature: -20 to 70
NFBU200-S1 p p Weight: 1.0kg
(DIN rail-mounted)
Short base module p p Max current consumption: 0.025 A (5 V) (Self-consumption)
NFBU050-S1 Weight: 0.58kg
(DIN rail-mounted) Operation temperature: -40 to 70
POWER SUPPLY MODULES FCN : Use with FCN RTU : Use with FCN-RTU
Model Name FCN* RTU* Specification
Power supply module p Duplex configuration: Possible
NFPW441
(100-120 V AC input) Hot-Swap: Possible
Rated output: + 5.1 V DC, 7.8 A
Power supply module
NFPW442 p Analog field power supply: Input: 24 V DC 10 %, 4 A, Duplexed (matching-diode)
(220-240 V AC input)
LED: SYS (5 V system power output ON), FLD (24 V field power supply ON)
Checking terminals: + 5 V, + 24 V
Power supply module p p
NFPW444 Weight: 0.6 kg
(24 V DC input)
Operation temperature: 0 to 55 (-20 to 70 for NFPW444)
Duplex configuration: Not applicable
Hot-Swap: Not applicable
Power supply module Rated output: +5.1 V DC (2.4 A) and +24 V DC (0.54 A)
NFPW426 (12 V DC input p LED: SYS (5 V system power output ON), FLD (24 V field power supply ON)
or 24 V DC input) Checking terminals: + 5 V, + 24 V
Weight: 0.61 kg
Operation temperature: -40 to 70
SB BUS REPEAT MODULES FCN : Use with FCN RTU : Use with FCN-RTU
Model Name FCN* RTU* Specification
Duplex configuration: Possible
Hot-Swap: Possible
Method: Serial communication (128 Mbps)
p Distance: Max. 8 m per segment
NFSB100 SB bus repeat module
LED: STATUS (Hardware Ready), SND (Sending), RCV (Receiving)
Max current consumption: 500mA (5 V DC)
Weight: 0.2 kg
Operation temperature: 0 to 55
Operation temperature range of the total component is decided by the narrowest range of each module (CPU, power supply, base, and I/O).
Model Description RTU* WTR* PCT* MIL Basic Specification Specification Common
Input response time: 160 ms or less
Functions:
Digital Input (for status input)
Status and Push button (edge count)
16 ch. p Min. ON detection time: 200 ms
NFDV141 N/A N/A N/A Max current consumption: per 8 ch.
100V to 120 V AC (for push button input)
500 mA (5 V DC)
Isolated Max. ON/OFF cycle: 2.5 Hz
Weight: 0.3 kg
(for push button input)
Input response time: 160 ms or less
Functions:
Digital Input (for status input)
Status and Push button (edge count)
16 ch. p Min. ON detection time: 200 ms
NFDV142 N/A N/A N/A Max current consumption: per 8 ch.
200 V to 240 V AC (for push button input)
500 mA (5 V DC)
Isolated Max. ON/OFF cycle: 2.5 Hz
Weight: 0.3 kg
(for push button input)
Input response time: 8 ms or less
Functions:
Digital Input p (for status input)
p Status and Push button (edge count)
32 ch. p p Min. ON detection time: 20 ms per 16 ch.
NFDV151 50 Max current consumption:
24 V DC -20 (for push button input) (Plus or Minus)
pins 500 mA (5 V DC)
Isolated Max. ON/OFF cycle: 25 Hz
Weight: 0.3 kg
(for push button input)
Input response time: 8 ms or less
Functions:
Digital Input (for status input)
Status
32 ch. p p Min. ON detection time: 20 ms per 16 ch.
NFDV157 N/A N/A Max current consumption:
24V DC (for push button input) (Plus or Minus)
350 mA (5 V DC)
Isolated Max. ON/OFF cycle: 25 Hz
Weight: 0.4 kg
(for push button input)
COMMUNICATION MODULES RTU : Use with FCN-RTU WTR : Wider temperature range (-40 to +70 )
p Max current consumption: 700 mA (5 V DC) Port: 1 port CiA 301 compliant D-sub 9 pins 25
NFLF121 CANopen communication module N/A
Weight: 0.3 kg 126 devices per module (male)
Common Specification LED: STATUS(Hardware normal), ACT(Operating), RCV(Receiving), SND(Sending)
SPECIFICATIONS MODULE
Model Description HART RTU* WTR* PCT* MIL Basic Specification Specification
Withstanding voltage:
500 V AC between input and system,
500 V AC between channels
Analog Input Transmitter power supply: 20.2 to 29.3 V Accuracy: 0.1 % of full scale
p
4 to 20 mA p (Output current limit: 25 mA) Data refresh cycle: 10 ms
NFAI135 p p p 40
8 ch. -20 Two wire and four wire transmitter setting Input step response time: 100 ms
pins per channel with connected terminal
Isolated ch. Temperature drift: Max. 0.01 % /
Max current consumption: 360 mA
(5 V DC), 450 mA (24 V DC)
Weight: 0.3 kg
Withstanding voltage:
1500 V AC between input and system
Analog Input Transmitter power supply: 24.0 to 25.5 V Accuracy: 0.1 % of full scale
p (Output current limit: 25 mA)
4 to 20 mA p Data refresh cycle: 10 ms
NFAI143 p p p 40 Two wire and four wire transmitter setting
16 ch. -20 per channel with pins Input step response time: 100 ms
pins
Isolated Max current consumption: 230 mA Temperature drift: Max. 0.01 % /
(5 V DC), 540 mA (24 V DC)
Weight: 0.3 kg
Analog Input
Accuracy: 0.1 % of full scale
-10 to +10 V p
Max current consumption: 350 mA (5 V DC) Data refresh cycle: 10 ms
NFAV142 16 ch. N/A N/A N/A p 40
Weight: 0.2 kg Input step response time: 100 ms
Non- pins
Temperature drift: Max. 0.01 % /
Isolated
TC input accuracy:
Input signal: Thermocouple or mV set for 0.03 % of full scale (-20 to 80 mV)
each channel from CH1 to CH16 mV input accuracy:
p
TC/mV Input Burn out detection: Possible 0.032 % of full scale (-100 to 150 mV)
40 (all channels together), Detection time: 60 s
NFAT141 16 ch. N/A p N/A p Data refresh cycle: 1 s
pins Withstanding voltage:
Isolated 1500 V AC between input and system TC input temperature drift:
*1
Max current consumption: 450 mA (5 V DC) Max. 30 ppm/
Weight: 0.2 kg mV input temperature drift:
Max. 32 ppm/
Model Description HART RTU* WTR* PCT* MIL Basic Specification Specification
Output fallback: Set for each channel Input accuracy: 0.1 % of full scale
Analog I/O Transmitter power supply: Output accuracy: 0.3 % of full scale
8 ch. input 22.8 to 26.4 V (Output current limit: 27 mA)
p Data refresh cycle: 10 ms
(4 to 20 mA) p Two wire and four wire transmitter setting
NFAI841 p p p 40 Input step response time: 100 ms,
8 ch. output -20 per channel with pins
pins Output step response time: 40 ms
(4 to 20 mA) Max current consumption:
310 mA(5 V DC), 500 mA(24 V DC) Temperature drift: Max. 0.01 % /
Non-Isolated
Weight: 0.3 kg
Analog I/O Input: Differential input (allowable common Input accuracy: 0.1 % of full scale
8 ch. Input mode voltage is 1 V or less) Output accuracy: 0.3 % of full scale
p
(1 to 5 V) Output fallback: Set for each channel Data refresh cycle: 10 ms
NFAB841 N/A p N/A p 40 Max current consumption:
8 ch. Output Input step response time: 100 ms,
pins 310 mA(5 V DC), 250 mA(24 V DC)
(4 to 20 mA) Output step response time: 40 ms
Weight: 0.3 kg
Non-Isolated Temperature drift: Max. 0.01 % /
Analog Output Output fallback: Set for each channel Output accuracy: 0.3 % of full scale
p
-10 to +10 V Max current consumption: 450 mA(5 V DC) Data refresh cycle: 10 ms
NFAV542 N/A N/A N/A p 40
16 channels Weight: 0.2 kg Output step response time: 40 ms
pins
Non-Isolated Temperature drift: Max. 0.01 % /
FCN/FCN-RTU (Long type, DIN rail-mounted) FCN/FCN-RTU (Short type, DIN rail-mounted)
131.0
131.0
FCN/FCN-RTU (Long type, 19 inch rack-mounted)
482.6 170.8
132.5
132.0
28
Power supply module SB bus repeat module Analog I/O module
<Model: NFPW441/NFPW442/ <Model: NFSB100> <Model:
NFPW444/NFPW426> NFAI135/NFAI141/NFAI143/
NFAV141/NFAV142/NFAV144/
NFAT141/NFAR181/NFAP135/
NFAF135/NFAI835/NFAI841/
NFAB841/NFAV542/NFAI543/
NFAV544>
130.0
130.0
130.0
Digital I/O module
<Model: NFDV151/ <Model: NFDV141/ <Model: NFDV157/ <Model: NFDV161/
NFDV551/NFDV532> NFDV142/NFDR541> NFDV557> NFDV561>
130.0
130.0
Terminal block
24.9
12.2 12.2
5.08
20.0
113.1
114.0
114.0
73.0
91.44
21.0
5.08
-0q : -1q:
Pressure clamp terminal block for Pressure clamp terminal block for MIL cable connector cover for ana-
analog module NFDV141, NFDV142, NFDV157, log and digital module
Pressure clamp terminal block for NFDV557, NFDR541
digital module
(NFDV151, NFDV532, NFDV551) 29
SPECIFICATIONS DIMENSIONS
130.5
32.8 126.7 32.8 142.9 13.5
112.0
32.8 94.0
130.0
130.0
130.0
121.0
4.5
CANopen FOUNDATION fieldbus
communication module communication module
<Model: NFLC121> <Model: NFLF111>
130.5 127.5
13.5 32.8 2.0 125.5
112.0 32.5
32.8 94.0 28.2 7.0
32.6 27.2
CH1
130.0
130.0
121.0
CH2
112.0
CH3
CH4
4.5
30
SELECTION GUIDE SOFTWARE
Software Selection
Name Model Suffix Codes/Options Codes
Software media
FCN/FCJ software media NT203AJ PC11E
FCN/FCJ Basic Software License (*1) System card 128MB 512MB 128MB NT205AJ NT203AJ
FCN/FCJ basic software license
Single CPU NT711AJ LS05E LM04E LM05E p
(System Card attached)
FCN basic software license
Duplexed CPU NT712AJ LM05E N/A N/A p
(Two system card attached )
Additional FCN/FCJ Java function license For NT711AJ-LS05E NT719AJ LW11A N/A N/A p
Hardware Selection
Name Model Suffix Codes/Options Codes
FCN-RTU Common Modules Standard with ISA standard G3 option Included Licenses
CPU Type Basic Extended Basic Extended
CPU module for FCN-RTU NFCP050 - S05 S06 NT711AJ-LM*, NT8001J, NT8035J, NT8036J
NFCP050 - S15 S16 Standard model + NT8017J, NT8105J
Power supply module 10-30VDC NFPW426 - 50 51
Power supply module 24VDC NFPW444 - 50 51
Installation 19inch rack DIN rail 19inch rack DIN rail
Base module (long) NFBU200 - S05 S15 S06 S16
Base module (short) NFBU050 - N/A S15 N/A S16
Foundation Fieldbus communication module (4-ports) NFLF111 - S50 S50/F9S00 S51 S51/F9S00 p
MIL connector cables Cable Length 0.5m 1.0m 1.5m 2.0m 2.5m 3.0m(*5)
MIL connector cable for analog, NFCP050 built-in I/O
KMS40 - 005 010 015 020 025 030
(40 pole plug types) (*3)
MIL connector cable (50 pole plug types) (*4)
KMS50 - 005 010 015 020 025 030
NFDV151,NFDV161,NFDV532, NFDV551, NFDV561
Cover
Dummy cover for I/O module slots NFDCV01
SB bus T-joint
SB bus T-joint NFSBT01
FCJ autonomous controller without FOUNDATION fieldbus interface NFJT100 - S105 S106
33
FCJ autonomous controller with FOUNDATION fieldbus interface (2-ports) NFJT100 - H105 H106
SELECTION GUIDE HARDWARE ( Explosion Model )
Hardware Selection
Name Model Suffix Codes/Options Codes
FCN-RTU Common Modules Standard with ISA standard G3 option Included Licenses
CPU Type Basic Extended Basic Extended
CPU module for FCN-RTU NFCP050 - S0E S0F NT711AJ-LM*, NT8001J, NT8035J, NT8036J
NFCP050 - S1E S1F Standard model + NT8017J, NT8105J
Power supply module 10-30VDC NFPW426 - E0 E1
Power supply module 24VDC NFPW444 - E0 E1
Installation 19inch rack DIN rail 19inch rack DIN rail
Base module (long) NFBU200 - S0E S1E S0F S1F
Base module (short) NFBU050 - N/A S1E N/A S1F
34
Name Model Suffix Codes/Options Codes
Foundation Fieldbus communication module (4-ports) NFLF111 - SE0 SE0/F9S00 SE1 SE1/F9S00 p
MIL connector cables Cable Length 0.5m 1.0m 1.5m 2.0m 2.5m 3.0m(*5)
MIL connector cable for analog, NFCP050 built-in I/O
KMS40 - 005 010 015 020 025 030
(40 pole plug types) (*3)
MIL connector cable (50 pole plug types) (*4)
KMS50 - 005 010 015 020 025 030
NFDV151, NFDV161, NFDV532, NFDV551, NFDV561
Cover
Dummy cover for I/O module slots NFDCV01
SB bus T-joint
SB bus T-joint NFSBT01
FCJ autonomous controller without FOUNDATION fieldbus interface NFJT100 - S10E S10F
FCJ autonomous controller with FOUNDATION fieldbus interface (2-ports) NFJT100 - H10E H10F
35
With the rapid pace of globalization in manufacturing, companies are hard pressed keeping their plants up and running all over the world. Rising to this
challenge, Yokogawa continues to expand its global service network, and currently counts 225 service offices all over the world. Our process industry
expertise and experience is second to none, and service and engineering personnel provide the same high-quality standard of service worldwide, over every
phase of the plant lifecycle. To ensure the availability of your global processes, look to Yokogawa.
Response Center Service Office
Trademarks
All brand or product names of Yokogawa Electric Corporation in this bulletin are trademarks or registered trademarks of Yokogawa Electric
Corporation. All other company brand or product names in this bulletin are trademarks or registered trademarks of their respective holders.