Вы находитесь на странице: 1из 4

SLAB 1 COMPUTATION

Design Criteria Slab Cases


Short Span: 6.0 m Case 1 Case 6
Long Span: 7.0 m
Case 2 Case 7
fc': 20.7 mPA
fy: 276 mPA
Case 3 Case 8
Live Load: 2.85 kPA
covering: 0.025 m
Case 4 Case 9
Steel Diameter: 12 mm
t= 0.125 m
Case 5

Moment Coefficients
CASE NO: 4
short =
m= 0.86
long
(-) Moment; (+) Moment LL:
(-)Cs: 0.0648 (+) Cs: 0.0422
(-) Cb: 0.0352 (+) Cb: 0.0236
(+)Moment D.L.:
(+) Cs: 0.0354
(+) Cb: 0.0196
DESIGN:
LOADS:
Dead Load: (considering one meter strip)
Wdl =23.54 x thickness Total Load:
DL = 2.94 KPA wu = 1.2 DL + 1.6 LL
Live Load: 2.85 KPA Wu = 8.09 KPA
MOMENTS
along short direction:
at midspan (+ Cs) (+) Mu = 1.2 DL + 1.6 LL at discountinuous edge
Mdl = Cs x Wdl x L^2 (+) Mu = 11.43 Kn.m M = (+) Mu / 3
Mdl = 3.75 Kn.m at continuous edge (- Cs) (+) M = 3.81 KN.m
Mll = Cs x Wll x L^2 (-) Mu = Cs x Wu x L^2
Mll = 4.33 Kn.m (-) Mu = 18.87 Kn.m
along long direction
at midspan (+ Cs) (+) Mu = 1.2 DL + 1.6 LL at discountinuous edge
Mdl = Cb x Wdl x L^2 (+) Mu = 8.66 Kn.m M = (+) Mu / 3
Mdl = 2.83 Kn.m at continuous edge (- Cs) (+) M = 2.89 KN.m
Mll = Cb x Wll x L^2 (-) Mu = Cb x Wu x L^2
Mll = 3.30 Kn.m (-) Mu = 13.96 Kn.m
REQUIRED REINFORCEMENT BARS
along short direction
at midspan along continuous
M = fc' bd^2 w (1-0.59w) M = fc' bd^2 w (1-0.59w)
w = 0.0571 w = 0.0967
p = wfc'/fy p = wfc'/fy
p = 0.0043 p = 0.0073
As = pbd As = pbd
As = 428.48 As = 725.24
s =1000 x Ab/As s =1000 x Ab/As
spacing = 263.82 spacing = 155.87
spacing = 250 mm spacing = 150 mm
along discontinuous
spacing = 3 x spacing at midspan
spacing = 750
spacing = 450 mm
along long direction
at midspan along continuous
M = fc' bd^2 w (1-0.59w) M = fc' bd^2 w (1-0.59w)
w = 0.0429 w = 0.0703
p = wfc'/fy p = wfc'/fy
p = 0.0032 p = 0.0053
As = pbd As = pbd
As = 322.09 As = 527.52
s =1000 x Ab/As s =1000 x Ab/As
spacing = 350.96 spacing = 214.29
spacing = 350 mm spacing = 210 mm

along discontinuous
spacing = 3 x spacing at midspan
spacing = 1053
spacing = 450 mm

TEMPERATURE BARS:
use : 12 mm bar
As(mm) = 0.002bt
As = 250
spacing = 452.16
say s = 450 mm
SLAB1 DETAIL:
1.75 3.5 1.75

12 mm dia temp bars spaced


1.5 at 450 m o.c. bothway

12 mm dia top bars spaced


3 at 210 m o.c.

1.5 12 mm dia top bars spaced


at 150 m o.c.

TOP BAR DETAIL


DRAWN NOT TO SCALE

1.75 3.5 1.75

1.5 12 mm dia bars spaced


at 450 m o.c. bothways

12 mm dia bars spaced


3 at 250 m o.c.

1.5 12 mm dia bars spaced


at 350 m o.c.

BOTTOM BAR DETAIL


DRAWN NOT TO SCALE