Вы находитесь на странице: 1из 43

May 2007

Abis & Ater Optimization

Presented by:
CBNetworks
Technical Support
support.technique@cbnetworks.fr
http://www.cbnetworks.fr
Agenda
Background

Vmux-400/420 features

How does it work?

Vmux-4.xx Configurator Tool

Statistics

Interoperability

Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 2


Optimization Market Needs
Market potential:
1 Billion potential cellular subscribers in GSM rural areas (Nokia
Chairman)
Cellular backhaul relies on leased lines, private networks and
satellite connections
Backhaul costs reach 40-60% of the operators OpEx
2.5G / 3G services and mobile users increase incurs additional
network investments (optimized 2G leased lines can be transferred
to 3G networks)

Connectivity optimization reduces costs

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 3


GSM Network Architecture
Interface: E(PCM) A(PCM) / Ater* Abis
Solution: Vmux-2100/ Vmux-2100 / 420* Vmux-400/420
Gmux-2000

BSC
BTS

BTS
PSTN
MSC BSC
BTS BTS

BTS
MSC
BSC
BTS BTS

BTS
HLR VLR
*Depends on the GSM Transcoder location: BTS
- if located at MSC Ater (Vmux-420)
- if located at BSC A Interface (Vmux-2100/Gmux-2000)

BTS Base Transceiver Station BSC Base Station Controller (= BSS)


MSC Mobile Switching Centre HLR & VLR Home & Visitor Location Registers
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 4
Optimization and not Compression

BSC

Ater Abis Optimized data

BTS

ABIS/ ATER contains:


1. Compressed voice
2. Idle channels
3. Silence within active calls
4. Signaling + headers [ = overhead]
5. Data (such as GPRS / EDGE)

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 5


Agenda
Background

Vmux-400/420 features

How does it work?

Vmux-4.xx Configurator Tool

Statistics

Interoperability

Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 6


Vmux-400 Features
Average Optimization: Up to 3:1 (fractional uplink)
User Input: 1 or 2xE1/T1 (ordering option)
Uplink Interfaces: E1/T1, ETH/IP, Serial (all built-in)
Clocking: Clock is transferred even when using ETH/IP
uplink
Power Options: AC/DC
Data compression: (NEW)
Compresses ~ 10% - 15% more
during peak hours (License is needed)
Point to Multipoint (using bundles)
Voice CODECs
Interoperability with all Major vendors
Tools, such as Bandwidth Calculator, Configurator
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 7
Vmux-420 (Beta) Features
All Vmux-400 features (except Serial Uplink & T1)
User Input: Up to 12xE1 (4, 8, or 12 - ordering option)
Uplink Interfaces: Up to 6xE1 or ETH/IP (all built-in)
Chassis: 1U, 19 wide
Redundancy: full redundancy (Carrier Class Product)
Dry Contact Alarm Relay
TDM trunks aggregation (grooming)
Interoperability between Vmux-400 and Vmux-420

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 8


Vmux-420 Back Panel

2 Fully redundant Main Modules, in case of H.W


malfunction
All ports connected to both Main Modules, supplying FULL
redundancy

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 9


Vmux-400/420 Management
User terminal
Telnet
RV-LITE + SNMP traps

ConfiguRAD

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 10


Agenda
Background

Vmux-400/420 features

How does it work?

Vmux-4.xx Configurator Tool

Statistics

Interoperability

Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 11


Operation

Optimization process
1. Suppress Idle channels
2. Suppress traffic when there are Silence frames within active calls*
3. Remove Signaling HDLC flags (only valid signaling is transferred)
Suppress signaling FISU & LSSU (ATER segment only)

Vmux-400/420

FROM Vmux-400/420 ABIS (/ ATER)


Optimized Data Compressed Voice
BSC 1
(MSC) BTS (/BSC)

Optimization

(* when DTX mode is active in the GSM network)


http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 12
Data Compression
How does it works?
- The data compression unit accumulates information coming from the optimization unit and
compresses it. The information is compressed similar to Zip a file in PC
Performance
- Saves about 10 - 15% bandwidth during peak hours.
- Higher performance when there is more Data traffic (GPRS / EDGE - up to 50%)
- There are 2 compression levels: Normal level and High level.
Why Data?
- The output from the optimization unit contains data and not voice
- This is non-destructive compression.
Tradeoff for High Packet loss level
- Sensitive to packet loss therefore it is only good for networks with low packet loss.
License dependant

Vmux-400/420

Vmux-400/420 ABIS / ATER


Optimized + Compressed Data Compressed Voice
1 2
BTS

Optimization Data
Compression
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 13
Traffic Types Supported VOICE

Voice Codecs:
FR (Full Rate)
EFR (Enhanced Full Rate)
AMR (Adaptive Multi-Rate)

HR (Half Rate) Up to 24 timeslots


AMR-HR Per Vmux-400 *

Vmux-400/420 can automatically


detect the GSM sub-channel rate
(16kbps or 8kbps)

* Current H.W. limitation (there is no limitation for the Vmux-420)


http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 14
Traffic Types Supported DATA
SMS / WAP:
Transferred as part of the signaling channel.

GPRS:
CS* 1,2,3 and 4 transported over timeslots
configured for TRAU traffic => BTS can use
any TRAU timeslot to transmit GPRS

EDGE:
Transported over timeslots configured for
TRANSPARENT.
BTS must use a predefined set of
timeslots for EDGE services

*CS = Code Scheme


http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 15
Clocking over TDM/IP Link

RCV (Uplink) RCV (Ingress)


TDM\IP
Network
Vmux-400 Vmux-400/420

ADAPTIVE = ENABLE ADAPTIVE = ENABLE


For IP uplink For IP uplink

BTS BSC
(LBT) )Clk Source(

Clock transferred from BSC to BTS over any transmission


network (Adaptive clock recovery mechanism enables to transfer
the clock over ETH/IP unique feature!)

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 16


Clocking over Satellite IP Link

Internal RCV (Ingress)

Vmux-400/OCXO Vmux-400/420

ADAPTIVE = DISABLE IP network ADAPTIVE = DISABLE

BTS BSC
(LBT) )Clk Source(

OCXO* (ordering option) for highly accurate internal oscillator


operating at 2.048Mhz 0.5 ppm (use when IP network jitter is
higher than 50 msec)

* Only needed on the BTS side


http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 17
Signaling Rate Detection
Signaling Rate Detection
Vmux-400/420 can automatically detect the data rate of the signaling channels (16,
32 or 64Kbps)
Before Vmux- 400/420 detects After Vmux- 400/420 detects
signaling channels rate signaling channels rate
Ts# Type Byte Bundle# Ts# Type Byte Bundle#
Reversal Reversal

1 Dynamic Yes 1 1 Sig64 Yes 1


2 Dynamic Yes 1 2 Sig64 Yes 1
| 3 Dynamic Yes 1 | 3 Sig64 Yes 1
v 4 Dynamic Yes 1 v 4 Dynamic Yes 1
5 Dynamic Yes 1 5 Dynamic Yes 1
6 Dynamic Yes 1 6 Dynamic Yes 1
7 Dynamic Yes 1 7 Dynamic Yes 1
8 Dynamic Yes 1 8 Dynamic Yes 1
9 Dynamic Yes 1 9 Dynamic Yes 1
10 Dynamic Yes 1 10 Dynamic Yes 1

Available Time Slot Types:


TRAU: GSM Speech
All
Allset
setto
toDynamic
Dynamic Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps
Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 18
Timeslot Type Detection (Ericsson)
Timeslot Type Detection (Ericsson)
Ericsson
After reboot, the Ericsson BSS changes timeslot assignment for speech and signaling. To
support this Vmux-400/420 can automatically detect the timeslot type (speech or signaling).
Before Vmux-400/420 detects timeslots type After Vmux-400/420 detects timeslots type
Ts# Type Byte Bundle# Ts# Type Byte Bundle#
Reversal Reversal

1 Dynamic Yes 1 1 Sig64 Yes 1


2 Dynamic Yes 1 2 Sig64 Yes 1
| 3 Dynamic Yes 1 | 3 Sig64 Yes 1
v 4 Dynamic Yes 1 v 4 TRAU Yes 1
5 Dynamic Yes 1 5 TRAU Yes 1
6 Dynamic Yes 1 6 TRAU Yes 1
7 Dynamic Yes 1 7 TRAU Yes 1
8 Dynamic Yes 1 8 TRAU Yes 1
9 Dynamic Yes 1 9 Dynamic Yes 1
10 Dynamic Yes 1 10 Dynamic Yes 1

Available Time Slot Types:


All
Allset
setto
toDynamic
Dynamic TRAU: GSM Speech
Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps
Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 19
Agenda

Background

Vmux-400/420 features

How does it work?

Vmux-4.xx Configurator Tool

Statistics

Interoperability

Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 20


Vmux-4.xx Configurator Tool:
Step 1
1. Site survey
1. Site survey 2. Configuration
3. Bandwidth
estimation
Collecting information from the Configuration Tool
mobile operator:

- GSM segment: ATER/ ABIS


- Vendor
- Uplink type: TDM / IP
- Timeslot assignment
- Downstream DTX (y/n)
- Clock transfer

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 21


Vmux-4.xx Configurator Tool:
Step 2
1. Site survey
2. Configuration parameters 2. Configuration
3. Bandwidth
estimation
Configure device according to Configuration Tool
the information we got from
the survey.

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 22


EXAMPLE:
Alcatel Time Slot Configuration
1. Site survey
BSC/BTS Configuration:
2. Configuration
(6 x TRX, 48 GSM speech channels)
3. Bandwidth
estimation

Vmux-400 Time Slot Table: Configuration Tool


Display Time Slots Configuration

Ts# Type Byte Reversal Bundle#


1 -- Yes 1
2 Sig64 Yes 1
| 3 TRAU Yes 1
v 4 TRAU Yes 1
5 Sig16 Yes 1
6 TRAU Yes 1
7 TRAU Yes 1
8 TRAU Yes 1
9 TRAU Yes 1
10 TRAU Yes 1

Available Time Slot Types:


TRAU: GSM Speech
Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps
Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 23
Vmux-4.xx Configurator Tool:
Step 3
1. Site survey

3. Bandwidth considerations 2. Configuration


3. Bandwidth
estimation
Bandwidth is influenced by the Configuration Tool
following parameters:

Fixed
- Timeslot assignment
- Uplink type (IP or TDM)
- Using Downstream DTX.

Estimated
- Estimated silence within calls
- Estimated idle channels

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 24


Vmux-4.xx Configurator Tool:
1. Site survey
Vmux-400/420 Configuration tool
2. Configuration
3. Bandwidth
estimation

Configuration Tool
Vmux-400 Configuration guide

Try
Try itit in
in workshop
workshop

Available at: http://www.cbnetworks.fr/ftp/rad/outils/ InfoCenter Technical Resources


http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 25
Agenda

Background

Vmux-400/420 features

How does it work?

Vmux-4.xx Configurator Tool

Statistics

Interoperability

Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 26


Statistics

Uplink statistics: TDM/Serial/Ethernet uplink:


Evaluate bandwidth on uplink
Signaling statistics:
Verify signaling channels are up
TRAU statistics:
TRAU traffic analyzing
Bandwidth control statistics:
Display calls stopped or discarded
BW utilization statistics:
Display enhanced information
on bandwidth consumption

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 27


Agenda

Background

Vmux-400/420 features

How does it work?

Vmux-4.xx Configurator Tool

Statistics

Interoperability

Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 28


Vmux-400 Interoperability

Interoperable with all major vendors:

Ericsson, Siemens, Nokia, Alcatel-


Lucent, Huawei, Motorola, Nortel,

Vmux-400/420

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 29


Agenda
Background

Vmux-400/420 features

How does it work?

Vmux-4.xx Configurator Tool

Statistics

Interoperability

Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 30


GSM Service to Remote / Rural
Regions
Remote Site

Central Office /ETH Vmux-400


IP
E1
MSC BSC ETH/IP BTS
Vmux-400
E1s E1
Hub
Transceivers Remote Site
E1

Vmux-400

/ETH Vmux-400
IP
E1
Central site BTS
solution is needed
Connection via satellite, microwave, terrestrial links, flexible
interfacing (IP/ETH/SERIAL/E1)
Effective solution where the cellular operator pays for expensive
transmission links
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 31
GSM Service to Remote / Rural
Regions
Remote Site

Central Office /ETH Vmux-400


IP
E1
MSC BSC BTS
Vmux-420
E1s
Hub
Transceivers Remote Site
ETH/IP
Up to 12 E1

/ETH Vmux-400
IP
E1
BTS

Connection via satellite, microwave, terrestrial links, flexible


interfacing (IP/ETH/SERIAL/E1)
Effective solution where the cellular operator pays for expensive
transmission links
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 32
Summary

RAD offers a full MSC-BSC-BTS cellular backhaul solution

Cost effective voice optimization solution for central and


remote sites

Up to 3:1 optimization of Abis/ Ater interface

Up to 10% - 15% saving with Data Compression

Connects over any uplink

Interoperable with all major vendors

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 33


thank you
for your attention

Technical Support
support.technique@cbnetworks.fr
http://www.cbnetworks.fr
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 34
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 35
Vmux-400 Ports

Control Port

E1 Uplink Serial Uplink


ETH Management
(Egress/Output) (Egress/Output)
to network to network

User E1 Ports* ETH/IP Uplink


(Ingress/Input) (Egress/Output)
from BTS/BSC/MSC to network

* Ordering Options: 1 or 2 ingress E1 ports


http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 36
Vmux-420 Ports

Up to 6 E1 Uplink Control
Up to 12 User E1
(Egress/Output) Port 2 Redundant
Ports*
to network Power
(Ingress/Input)
ETH supplies
from
Management Alarm
BTS/BSC/MSC ETH/IP Uplink Relay
port
(Egress/Output)
to network

* Ordering Options: - 4,8 or 12 Ingress E1 ports


- 2,4 or 6 Egress E1 ports
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 37
GSM Subchannel Rate Detection
GSM Subchannel Rate Detection
Full Rate (FR): Each voice
channel is carried in a 16 kbps
sub channel

Half Rate (HR): Each voice


channel is carried in a 8 kbps sub
channel

Vmux-400/420 can automatically


detect the GSM subchannel rate
(16 kbps or 8 kbps)

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 38


Ericsson Time Slot Configuration
BSC/BTS Configuration:
(10.5 x TRX, 84 GSM speech channels)
CH Sub Channel Content

1 CONC TRXC SIGNAL


How to configure Vmux-4.xx according to
2 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA the timeslots table?
3 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
4 UNDEF IDLE
5 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA TS1, 21, 30 : Sig64
6 UNDEF IDLE
7 UNDEF IDLE TS2, 3, 5, 11-20, 24, 29, 31 : TRAU
8 UNDEF IDLE
9 UNDEF IDLE TS4, 6-10, 22-23, 25-28: : N/C.
10 UNDEF IDLE
11 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
12 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
13 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
14 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
15 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
17 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
18 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
19 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
20 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA
21 CONC TRXC SIGNAL
22 UNDEF IDLE
23 UNDEF IDLE
24 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA Available Time Slot Types:
25 UNDEF IDLE
26 UNDEF IDLE TRAU: GSM Speech
27 UNDEF IDLE
Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps
28 UNDEF IDLE
29 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps
30 CONC CF/TRXC SIGNAL
31 MPLEX16 MPLEX16 MPLEX16 MPLEX16 SPEECH/DATA

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 39


Statistics: BW Utilization Statistics
Vmux400 / BSC ALRM
Display Total Accumulated Number
Numberof
ofseconds
seconds
accumulated
accumulatedfor
foreach
each
bandwidth
bandwidthrange
range

[ < 64 Kbps] ... (236024) [704 -767 Kbps] ... (44)


[ 64 -127 Kbps] ... (5) [768 -831 Kbps] ... (354)
[128 -191 Kbps] ... (314) [832 -895 Kbps] ... (233)
[192 -255 Kbps] ... (1203) [896 -959 Kbps] ... (23)
[256 -319 Kbps] ... (3455) [960 -1023 Kbps] ... (4)
[320 -383 Kbps] ... (14563) [1024-1087 Kbps] ... (0)
[384 -447 Kbps] ... (21003) [1088-1151 Kbps] ... (0)
[448 -511 Kbps] ... (13900) [1152-1215 Kbps] ... (4)
[512 -575 Kbps] ... (4231) [1216-1279 Kbps] ... (0)
[576 -639 Kbps] ... (911) [1280-1343 Kbps] ... (0)
[640 -703 Kbps] ... (43) [1344-1407 Kbps] ... (0)
... (N)
>

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 40


Mobile Platforms

MSC BSC Vmux-400 Vmux-400


E1s Serial/
IP/E1 Serial/IP/E1
E1
E1
BTS

Supply service to mobile platforms such as cruise ships

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 41


Mobile Platforms

MSC BSC Vmux-400 Vmux-400


E1s Serial/
IP/E1 Serial/IP/E1
E1
E1
BTS

Supply service in large and crowded events using trucks

http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 42


Terrestrial Daisy Chained BTSs

FE1

BTS
FE1

BTS
MSC BSC Vmux-400 / 420 Vmux-400
E1s E1 E1
BTS
TDM or IP E1

FE1
DXC
BTS
FE1

FE1 BTS

BTS

Requires Drop & Insert capability at the BTS


Suitable when each BTS serves a small area
http://www.cbnetworks.fr - support.technique@cbnetworks.fr Abis & Ater Gateway TS-2007 Slide 43

Вам также может понравиться