Installation tools and torque values

Appendix A Installation tools and torque values

A.1 Installation tools for Flexi EDGE BTS

This list covers all Flexi EDGE BTS installation options: stack, wall, pole,
Flexi Cabinet for Indoor (FCIA), Flexi Cabinet for Outdoor (FCOA), Citytalk
cabinet, feederless sites.

Table 7. Installation tools

Installation tools Usage


ESD wrist strap and cable Module/sub-module installation
TORX screwdriver set: T10, T20, T25, T45 .
Installing modules (T25)
. Installing casing kits (T25)
.
Module grounding (T25)
.
FCIA/FCOA/FCFA/FCSA/FMFA mechanics
(T25)
. Installing sub-modules (T20)
.
Fan plate assembly (T20)
. Anchoring EMIA standoff casing (T45)
. FCIA site grounding (T45)
.
Isolating cable clamps (T10)
.
EMIA door alarm kit (T10)
Socket or open-ended spanner (wrench) set: . DC power terminal nuts (17 mm)
8 mm (5/16 in.), 13 mm (1/2 in.), 17 mm (11/16) in.), 19 mm . Plinth site grounding (13 mm)
(13/16 in.) . FCOA site grounding (13 mm, 8 mm)
Torque wrench is recommended for fastening the DC input lug. .
Anchoring cabinets/plinths (19 mm)

Folding knife .
Unpacking
. Routing cables through cable entries
.
Preparing power and ground cables
Adjustable wrench General installation tool
Side cutters Cutting tie wraps, general installation tool
2 2 2
Crimping tool for 16 mm (6 AWG), 25 mm (4 AWG), 35 mm Grounding and DC power input cables
(2 AWG), or 50 mm2 (1/0 AWG) cable lugs
Torque wrench for antenna cables (size depends on antenna Connecting antenna cables to ERxA or ECxA
jumper/feeder cable size and manufacturer)
Cable ties Routing cables
Tape measure General installation tool
Flashlight, pocket lamp or torch General installation tool

DN70128475 # Nokia Siemens Networks 67 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

Table 7. Installation tools (cont.)

Installation tools Usage


Drill with bit set: 10 mm (3/8 in.), 12 mm (15/32 in.) .
Anchoring cabinets/plinths (12 mm)
.
EMIA installation (10 mm)
Marker, pen, or comparable tool General installation tool
Pliers General installation tool
Level General installation tool
Flathead screwdriver FPMA AC power terminals
Allen (Hexagon) keys: 4 mm (5/32 in.), 5 mm (3/16 in.), 6 mm . VMPB/FPKA pole mounting kit (8 mm)
(7/32 in.), 8 mm (5/16 in.) .
EMIA installation (4 mm, 5 mm, 6 mm)
. Feederless sites (grounding kit) (5 mm)
Thread locking compound (medium strength, non-permanent), .
Installation on a pole or wall
for example Loctite 242 or equivalent . FMSA
Vacuum cleaner or broom with dust pan EMIA installation
Saw Feederless sites
Heat gun for cable shrinking sleeves Feederless sites

A.2 Torque values

Nokia Siemens Networks strongly recommends that you tighten to the


following torque values. These values assume the use of a lubricated bolt
or fastener. Use these values unless stated otherwise.

DN70234447

Figure 33. Torque wrench

68 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Installation tools and torque values

Table 8. Torque values for the BTS

Size Type Usage Torque


M3 Screw, TORX pan head EMIA 1.5-2.0 Nm (1.11-1.47 ft-
lb)
M4 Screw, TORX cylinder FCSA and FCFA fans 1.2 - 1.6 Nm (0.9 - 1.2 ft-
head lb)
M4 Screw, TORX pan head . EWxx and FIxA installation 2.7-3.3 Nm (1.99-2.43 ft-
or thumb (knurled head) .
ESMA, EXxA, ECxA, ESEA, and lb)
FPDA fan plate assembly
. FMAA
M5 Screw, TORX thumb EMxA front and rear covers 2.0 - 2.5 Nm (1.5-1.8 ft-
(knurled head) or pan lb)
head
M5 Screw, TORX pan head .
EMxA casings and cable entries 3.5-4.2 Nm (2.58-3.10 ft-
or thumb (knurled head) .
Mounting modules lb)
.
Auxiliary boxes
. EMIA
. Module grounding
.
FCIA site grounding (NEBS)
. FMAA
M5 Nut, Hex FCOA site grounding 3 Nm
M5 Screw, slotted flathead .
EMIA 3.5-4.2 Nm (2.58-3.10 ft-
.
Module grounding lb)

M6 Screw, Allen or TORX .


EMIA 4.2-5.8 Nm (3.1-4.28 ft-
head .
FMAA lb)

M6 Nut, Hex EMIA 4.2-5.5 Nm (3.1-4.05 ft-


lb)
M8 Screw, TORX or hex FCIA/EMIA/plinth site grounding 8.0-10.0 Nm (5.9-7.37 ft-
head lb)
M8 Nut, Hex FCOA site grounding 5 Nm
M8 Screw, hex head Plinth adapter mechanics 10.0 Nm (7.37 ft-lb)
M10 Nut, Hex ESMA, ESEA, FPDA and EOCA DC 10.0 - 14.0 Nm (7.0 - 9.8
power terminals ft -lb)
M10 Bolt, Allen head VMPB/FPKA pole mounting kits 29 Nm (21.4 ft-lb)
M12 (15/32 Anchoring bolts Anchoring FCIA/FCOA/FMFA to floor 49.0 Nm (36.1 ft-lb)
in.) (not included in Flexi EDGE delivery)
7/16 DIN Antenna connector Antenna jumper cables (not included 25 Nm (18.5 ft-lb
in Flexi EDGE delivery)

DN70128475 # Nokia Siemens Networks 69 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

Appendix B Bending diameter for cables

B.1 Bending diameter for cables

The table below shows the minimum bending diameter of Nokia Flexi
EDGE BTS cables.

Static bending diameter refers to the allowed bend while the cable is fixed
(for example, when the cable is tied to the side of the cabinet). Dynamic
bending diameter refers to the allowed bend while the cable is in motion
(for example while routing the cable through the cable entry).

For the bending diameter of antenna jumper cables, refer to the cable
manufacturer.

Table 9. Bending diameter of Nokia Flexi EDGE BTS cables

Cable Static bending Dynamic bending


diameter diameter
Cable name Cable code
RF cable 172 mm (6.8 in.) 994931 30 mm (1.2 in.) 35 mm (1.4 in.)
RF cable 275 mm (10.8 in.) 994933
RF cable 1300 mm (51.2 in.) 994936
RF cable 71 mm (2.8 in.) 994980 18 mm (0.7 in.) 18 mm (0.7 in.)
Bus cable 1054 mm (41.5 in.) 994938 40 mm (1.6 in.) 45 mm (1.8 in.)
Bus cable 1554 mm (61.2 in.) 994939
Power cable 1188 mm (46.8 in.) 994940 45 mm (1.8 in.) 50 mm (2.0 in.)
1)
Optical cables 140 mm (5.6 in.) 140 mm (5.6 in.)
DP cable 994969 40 mm (1.6 in.) 45 mm (1.8 in.)
EMCA LMP cable 471370
Sync cable for Flexi 471371
Sync cable for UltraSite 471372
Sync LMU cable 471377
Q1 cable 471384
MIBBU EPA alarm cable 471464
Clock test cable 471521

70 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Bending diameter for cables

1)
See the product codes for optical cables in Contents of the transmission
cable deliveries (FIQA FIYA) in Nokia Flexi EDGE BTS System Module
(ESMA) Description and Contents of the optical cable deliveries in
Optional Items Description.

DN70128475 # Nokia Siemens Networks 71 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

Appendix C Configuration features

C.1 Flexi EDGE BTS configuration features

C.1.1 RF Cable Auto-detection

The Flexi EDGE Base Station supports automatic RF Cable Auto-


detection during commissioning for common configurations. RF Cable
Auto-detection reduces integration time because RF cabling does not
need to be manually defined.

For a description of RF Cable Auto-detection, see Auto-detection of Site


Configuration and RF Cable Auto-detection in the Nokia Flexi EDGE BTS
Feature Descriptions document.

For information on supported configurations, see RF auto-detection


supported configurations in the Nokia Flexi EDGE BTS Commissioning
document.

C.1.2 Optimised configurations

Upgrade-optimised configurations

In upgrade-optimised configurations, odd-number sectors (such as 1+1, 3


+3+3, 5+5) are built like the next even-numbered configurations. For
example, a 1+1 configuration is built like a 2+2 configuration, although the
site is operational as a 1+1. This allows easy future expansion with
reduced downtime. A site visit may not be needed for expansion.

RF Cable Auto-detection is supported with upgrade-optimised


configurations.

For examples of RF cabling in upgrade-optimised configurations, see


figures Example of a 1+1 upgrade-optimised configuration with Rx
diversity below and RF cables in 1+1+1/2+2+2 bypass 2UD configuration
in section Connecting RF cables.

72 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Configuration features

TxA-TxA RxAO-RxAI* RxA1-RxA RxB1-RxB TxB-TxB


Sector 2

TRX3 TRX4
Sector 1

TRX1 TRX2

TxA-TxA RxAO-RxAI* RxA1-RxA RxB1-RxB TxB-TxB

*RxAO-RxAI is pre-installed DN70475304

The dotted line indicates that the cable is installed but it is not in use.

Figure 34. Example of a 1+1 upgrade-optimised configuration with Rx diversity

Cost-optimised configurations

In cost-optimised configurations, the Dual TRX Module (EXxA) carriers (A


and B) are split into separate cell areas. Only pairs of odd-numbered
configurations can be cost-optimised (such as 1+1, 3+3). Cost-optimised
configurations minimise the number of modules and are not recommended
if future expansion is possible at the site.

RF Cable Auto-detection supports cost-optimised configurations.

DN70128475 # Nokia Siemens Networks 73 (158)


Issue 3-0 en
17/06/2008
Creating FCOA Configurations

For an example of RF cabling in cost-optimised configurations, see figures


RX cables in a cost-optimised 3+3 configuration and TX cables in a cost-
optimised 3+3 configuration in section 3+3 2-way 2UD cost-optimised
configuration.

Antenna-optimised configurations

Antenna-optimised configurations allow the Dual Duplexer Module (ERxA)


sides A and B to be split into separate cell areas. This minimises the
number of antennas.

A sector must have two or more antennas to support Rx diversity, as Rx


diversity is not supported across BTS cells.

RF Cable Auto-detection supports antenna-optimised configurations with


one exception: a BCF reset is needed instead of a sector reset, if any
changes to RF cabling are made during runtime.

RxA-RxA1

OUT-TxA TxA-TxA RxB1-RxB TxB-TxB


Sector 1

DN
Sector 2

DN

RxA0-RxAI* TxA-TxA RxB-RxB2 TxB-TxB

RxA-RxB1 OUT-TxB

DN70475316

RxAO-RxAI is pre-installed.

74 (158) # Nokia Siemens Networks DN70128475


Issue 3-0 en
17/06/2008
Configuration features

Figure 35. Example of a 2 +2 antenna-optimised configuration, without diversity

TxA-TxA RxA0-RxAI RxB-RxB1


TxA-TxA RxA-RxA1 RxB-RxB2 TxB-TxB
Sector 2

TRX5 TRX6

DN

TRX7

TRX3
Sector 1

TRX1 TRX2

TxA-TxA RxA0-RxAI RxA-RxA1 RxA-RxA2 RxB-RxB1 TxB-TxB

DN70475328

RxAO-RxAI is pre-installed.

Figure 36. Example of a 3 +3 antenna-optimised configuration with Rx Diversity