Академический Документы
Профессиональный Документы
Культура Документы
ADMINISTRATION
1
101.5 102.2 UNIFORM PLUMBING CODE
101.5 Application to Existing Plumbing System 102.2 Duties and Powers of the Administrative
101.5.1 Additions, Alterations or Repairs. Authority
Additions, alterations or repairs may be made to 102.2.1 The Administrative Authority may
any plumbing system without requiring the appoint such assistants, deputies, inspectors, or
existing plumbing system to comply with all the other employees as are necessary to carry out the
requirements of this Code, provided the addition, functions of the department and this Code.
alteration or repair conforms to that required for a 102.2.2 Right of Entry. Whenever it is
new plumbing system. Additions, alterations or necessary to make an inspection to enforce the
repairs shall not cause an existing system to provisions of this Code, or whenever the
become unsafe, insanitary or overloaded. Administrative Authority has reasonable cause
101.5.2 Health and Safety. Whenever to believe that there exists in any building or
compliance with all the provisions of this Code upon any premises, any condition or violation of
fails to eliminate or alleviate a nuisance, or any this Code which make the building or premises
other dangerous or insanitary condition which unsafe, insanitary, dangerous or hazardous, the
may involve health or safety hazards, the owner Administrative Authority may enter the building
or the owner's agent shall install such additional or premises at all reasonable times to inspect or
plumbing and drainage facilities or shall make to perform the duties imposed upon the
such repairs or alterations as may be ordered by Administrative Authority by this Code, provided
the Administrative Authority. that if such building or premises is occupied, the
101.5.3 Existing Installation. Plumbing Administrative Authority shall present
systems lawfully in existence at the time of the credentials to the occupant and request entry. If
adoption of this Code may have their use, such building or premises is unoccupied, the
maintenance or repair continued if the use, Administrative Authority shall first make a
maintenance or repair is in accordance with the reasonable effort to locate the owner or other
original design and location and no hazard to person having charge or control of the building
life, health or property has been created by such or premises and request entry. If entry is refused,
plumbing system. the Administrative Authority has recourse to
101.5.4 Changes in Building Occupancy. every remedy provided by law to secure entry.
Plumbing systems which are a part of any building When the Administrative Authority shall
or structure undergoing a change in use or have first obtained a proper inspection warrant
occupancy, as defined in the Building Code, shall or other remedy provided by law to secure
comply to all requirements of this Code which entry, no owner, occupant, or person having
may be applicable to the new use or occupancy. charge, care, or control of any building or
101.5.5 Maintenance. All plumbing systems, premises shall fail or neglect, after proper
materials and appurtenances, both existing and request is made as herein provided, to promptly
new, and all parts thereof shall be maintained in permit entry herein by the Administrative
proper operating condition. All devices or Authority for the purpose of inspection and
safeguards required by this Code shall be examination pursuant to this Code.
maintained in conformance with the Code 102.2.3 Stop Orders. Whenever any work is
edition under which installed. The owner or the being done contrary to the provisions of this
owners designated agent shall be responsible Code, the Administrative Authority may order
for maintenance of plumbing systems. To the work stopped by notice in writing served on
determine compliance with this subsection, the any persons engaged in the doing or causing
Administrative Authority may cause any such work to be done, and any such persons
plumbing system to be reinspected. shall forthwith stop work until authorized by
101.5.6 Moved Buildings. Plumbing systems the Administrative Authority to proceed with
which are part of buildings or structures moved the work.
into this jurisdiction shall comply with the 102.2.4 Authority to Disconnect Utilities in
provisions of this Code for new installations Emergencies. The Administrative Authority
except as provided for in Section 103.5.5.2. shall have the authority to disconnect a
plumbing system to a building, structure or
102.0 Organization and Enforcement equipment regulated by this Code in case of
102.1 Administrative Authority emergency where necessary to eliminate an
The Administrative Authority shall be the Authority immediate hazard to life or property.
duly appointed to enforce this Code.
2
ADMINISTRATION 102.2 103.2
102.2.5 Authority to Condemn. Whenever the cause the same to be done without first
Administrative Authority ascertains that any obtaining a separate plumbing permit for each
plumbing system or portion thereof, regulated separate building or structure.
by this Code, has become hazardous to life, 103.1.2 Exempt Work. A permit shall not be
health, property, or has become insanitary, the required for the following:
Administrative Authority shall order in writing
103.1.2.1 The stopping of leaks in drains,
that such plumbing either be removed or placed
soil, waste or vent pipe, provided, however,
in a safe or sanitary condition, as appropriate.
that should any trap, drainpipe, soil, waste
The order shall fix a reasonable time limit for
or vent pipe become defective and it
compliance. No person shall use or maintain
becomes necessary to remove and replace
defective plumbing after receiving such notice.
the same with new material, the same shall
When such plumbing system is to be be considered as new work and a permit
disconnected, written notice shall be given. In shall be procured and inspection made as
cases of immediate danger to life or property, provided in this Code.
such disconnection may be made immediately
103.1.2.2 (1) The clearing of stoppages,
without such notice.
including the removal and reinstallation of
102.2.6 Liability. The Administrative Authority water closets or;
charged with the enforcement of this Code,
(2) the repairing of leaks in pipes, valves or
acting in good faith and without malice in the
fixtures, provided such repairs do not
discharge of the Administrative Authoritys
involve or require the replacement or
duties, shall not thereby be rendered personally
rearrangement of valves, pipes, or fixtures.
liable for any damage that may accrue to persons
or property as a result of any act or by reason of Exemption from the permit
any act or omission in the discharge of duties. A requirements of this Code shall not be
suit brought against the Administrative deemed to grant authorization for any work
Authority or employee because of such act or to be done in violation of the provisions of
omission performed in the enforcement of any the Code or any other laws or ordinances of
provision of this Code shall be defended by legal this jurisdiction.
counsel provided by this jurisdiction until final 103.1.3 Licensing. As a result of an agreement
termination of such proceedings. between the Department of Housing and Urban
102.3 Violations and Penalties Development (HUD) and IAPMO the requirements
for licensing have been removed from this section
102.3.1 Violations. It shall be unlawful for any
of the UPC. Provision for licensing shall be
person, firm or corporation to erect, construct,
determined by the Administrative Authority.
enlarge, alter, repair, move, improve, remove,
convert, demolish, equip, use, or maintain any 103.2 Application For Permit
plumbing or permit the same to be done in 103.2.1 Application. To obtain a permit, the
violation of this Code. applicant shall first file an application therefor in
102.3.2 Penalties. Any person, firm, or writing on a form furnished by the
corporation violating any provision of this Code Administrative Authority for that purpose.
shall be deemed guilty of a misdemeanor, and Every such application shall:
upon conviction thereof, shall be punishable by 103.2.1.1 Identify and describe the work to
a fine and/or imprisonment set forth by the be covered by the permit for which
governing laws of the jurisdiction. Each separate application is made.
day or any portion thereof, during which any 103.2.1.2 Describe the land upon which
violation of this Code occurs or continues, shall the proposed work is to be done by legal
be deemed to constitute a separate offense. description, street address or similar
description that will readily identify and
103.0 Permits and Inspections definitely locate the proposed building or
work.
103.1 Permits
103.2.1.3 Indicate the use or occupancy for
103.1.1 Permits Required. It shall be unlawful
which the proposed work is intended.
for any person, firm or corporation to make any
installation, alteration, repair, replacement or 103.2.1.4 Be accompanied by plans,
remodel any plumbing system regulated by this diagrams, computations and other data as
Code except as permitted in Section 103.1.2, or to required in Section 103.2.2.
3
103.2 103.3 UNIFORM PLUMBING CODE
4
ADMINISTRATION 103.3 103.5
may apply for an extension of the time within application after expiration, the applicant shall
which work may commence under that permit resubmit plans and pay a new plan review fee.
when the permittee is unable to commence work 103.4.4 Investigation Fees: Work Without a
within the time required by this section for good Permit
and satisfactory reasons. The Administrative
103.4.4.1 Whenever any work for which a
Authority may extend the time for action by the
permit is required by this Code has been
permittee for a period not exceeding one
commenced without first obtaining said
hundred eighty (180) days upon written request
permit, a special investigation shall be made
by the permittee showing that circumstances
before a permit may be issued for such work.
beyond the control of the permittee have
prevented action from being taken. No permit 103.4.4.2 An investigation fee, in addition
shall be extended more than once. In order to to the permit fee, shall be collected whether
renew action on a permit after expiration, the or not a permit is then or subsequently
permittee shall pay a new full permit fee. issued. The investigation fee shall be equal
to the amount of the permit fee that would
103.3.5 Suspension or Revocation. The
be required by this Code if a permit were to
Administrative Authority may, in writing,
be issued. The payment of such
suspend or revoke a permit issued under the
investigation fee shall not exempt any
provisions of this Code whenever the permit is
person from compliance with all other
issued in error or on the basis of incorrect
provisions of this Code, nor from any
information supplied or in violation of other
penalty prescribed by law.
ordinance or regulation of the jurisdiction.
103.4.5 Fee Refunds
103.4 Fees
103.4.5.1 The Administrative Authority
103.4.1 Permit Fees. Fees shall be assessed in
may authorize the refunding of any fee paid
accordance with the provisions of this section
hereunder which was erroneously paid or
and as set forth in the fee schedule Table 1-1. The
collected.
fees are to be determined and adopted by this
jurisdiction. 103.4.5.2 The Administrative Authority
may authorize the refunding of not more
103.4.2 Plan Review Fees. When a plan or
than a percentage, as determined by this
other data is required to be submitted by 103.2.2,
jurisdiction when no work has been done
a plan review fee shall be paid at the time of
under a permit issued in accordance with
submitting plans and specifications for review.
this Code.
The plan review fees for plumbing work shall be
determined and adopted by this jurisdiction. 103.4.5.3 The Administrative Authority may
authorize the refunding of not more than a
The plan review fees specified in this
percentage, as determined by this jurisdiction
subsection are separate fees from the permit fees
when no work has been done under a permit
specified in this section and are in addition to
issued in accordance with this Code.
the permit fees.
The Administrative Authority shall not
When plans are incomplete or changed so as
authorize the refunding of any fee paid
to require additional review, a fee shall be
except upon written application filed by the
charged at the rate shown in Table 1-1.
original permittee not later than one
103.4.3 Expiration of Plan Review. hundred eighty (180) days after the date of
Applications for which no permit is issued fee payment.
within one hundred eighty (180) days following
103.5 Inspections
the date of application shall expire by limitation
and plans and other data submitted for review 103.5.1 General. All plumbing systems for
may thereafter be returned to the applicant or which a permit is required by this Code shall be
destroyed by the Administrative Authority. The inspected by the Administrative Authority. No
Administrative Authority may exceed the time portion of any plumbing system shall be
for action by the applicant for a period not to concealed until inspected and approved. Neither
exceed one hundred eighty (180) days upon the Administrative Authority nor the
request by the applicant showing that jurisdiction shall be liable for expense entailed in
circumstances beyond the control of the the removal or replacement of material required
applicant have prevented action from being to permit inspection. When the installation of a
taken. No application shall be extended more plumbing system is complete, an additional and
than once. In order to renew action on an final inspection shall be made. Plumbing
5
103.5 UNIFORM PLUMBING CODE
systems regulated by this Code shall not be plumbing system, or part thereof, is set up
connected to the water, energy fuel supply, or for exhibition purposes and has no
the sewer system until authorized by the connection with a water or drainage system.
Administrative Authority. 103.5.3.3 Exceptions. In cases where it
103.5.1.1 Inspection. No water supply would be impractical to provide the
system or portion thereof, shall be covered required water or air tests, or for minor
or concealed until it first has been tested, installations and repairs, the Administrative
inspected, and approved. Authority may make such inspection as
103.5.1.2 Scope. All new plumbing work deemed advisable in order to be assured
and such portions of existing systems as that the work has been performed in
may be affected by new work, or any accordance with the intent of this Code.
changes, shall be inspected by the 103.5.3.4 Protectively Coated Pipe.
Administrative Authority to insure Protectively coated pipe shall be inspected
compliance with all the requirements of this and tested, and any visible void, damage or
Code and to assure that the installation and imperfection to the pipe coating shall be
construction of the plumbing system is in repaired to comply with Section 313.0 (see
accordance with approved plans. IAPMO IS-13, listed in Appendix I).
103.5.1.3 Covering or Using. No 103.5.3.5 Tightness. Joints and
plumbing or drainage system, building connections in the plumbing system shall be
sewer, private sewer disposal system or part gastight and watertight for the pressures
thereof, shall be covered, concealed, or put required by test.
into use until it has been tested, inspected, 103.5.4 Inspection Requests. It shall be the
and accepted as prescribed in this Code. duty of the person doing the work authorized by
103.5.1.4 Uncovering. Any drainage or a permit to notify the Administrative Authority
plumbing system, building sewer, private that such work is ready for inspection. The
sewage disposal system, or part thereof, Administrative Authority may require that
which is installed, altered, or repaired is every request for inspection be filed at least one
covered or concealed before being inspected, working day before such inspection is desired.
tested, and approved as prescribed in this Such request may be in writing or by telephone,
Code, it shall be uncovered for inspection at the option of the Administrative Authority.
after notice to uncover the work has been It shall be the duty of the person requesting
issued to the responsible person by the inspections required by this Code to provide
Administrative Authority. access to and means for proper inspection of
103.5.2 Operation of Plumbing Equipment. such work.
The requirements of this section shall not be 103.5.4.1 Advance Notice. It shall be the
considered to prohibit the operation of any duty of the person doing the work
plumbing installed to replace existing authorized by the permit to notify the
equipment or fixtures serving an occupied Administrative Authority, orally or in
portion of the building in the event a request for writing, that said work is ready for
inspection of such equipment or fixture has been inspection. Such notification shall be given
filed with the Administrative Authority not not less than twenty-four (24) hours before
more than seventy-two (72) hours after such the work is to be inspected.
replacement work is completed, and before any
103.5.4.2 Responsibility. It shall be the
portion of such plumbing system is concealed by
duty of the holder of a permit to make sure
any permanent portion of the building.
that the work will stand the test prescribed
103.5.3 Testing of Systems. All plumbing before giving the notification.
systems shall be tested and approved as required
The equipment, material, and labor
by this Code or the Administrative Authority.
necessary for inspection or tests shall be
103.5.3.1 Test. Tests shall be conducted in furnished by the person to whom the permit
the presence of the Administrative is issued or by whom inspection is
Authority or the Administrative Authority's requested.
duly appointed representative.
103.5.5 Other Inspections. In addition to the
103.5.3.2 Test Waived. No test or inspections required by this Code, the
inspection shall be required where a Administrative Authority may require other
6
ADMINISTRATION 103.5 103.8
inspections of any plumbing work to ascertain delivered to the permittee or his authorized
compliance with the provisions of this Code and representative. Refusal, failure, or neglect to
other laws which are enforced by the comply with any such notice or order within
Administrative Authority. ten (10) days of receipt thereof, shall be
103.5.5.1 Defective Systems. An air test considered a violation of this Code, and
shall be used in testing the sanitary shall be subject to the penalties set forth
condition of the drainage or plumbing elsewhere in this Code for violations.
system of any building premises when there 103.5.6.2 Retesting. If the Administrative
is reason to believe that it has become Authority finds that the work will not pass
defective. In buildings or premises the test, necessary corrections shall be made
condemned by the proper Administrative and the work shall then be resubmitted for
Authority because of an insanitary condition test or inspection.
of the plumbing system or part thereof, the 103.5.6.3 Approval. Upon the satisfactory
alterations in such system shall conform to completion and final test of the plumbing
the requirements of this Code. system, a certificate of approval shall be
103.5.5.2 Moved Structures. All parts of issued by the Administrative Authority to
the plumbing systems of any building or the permittee on demand.
part thereof that is moved from one 103.6 Connection Approval
foundation to another, or from one location
103.6.1 Energy Connections. No person shall
to another, shall be completely tested as
make connections from a source of energy or fuel
prescribed elsewhere in this section for new
to any plumbing system or equipment regulated
work, except that walls or floors need not be
by this Code and for which a permit is required
removed during such test when other
until approved by the Administrative Authority.
equivalent means of inspection acceptable to
the Administrative Authority are provided. 103.6.2 Other Connections. No person shall
make connection from any water-supply line nor
103.5.6 Reinspections. A reinspection fee may
shall connect to any sewer system regulated by
be assessed for each inspection or reinspection
this Code and for which a permit is required
when such portion of work for which inspection
until approved by the Administrative Authority.
is called is not complete or when required
corrections have not been made. 103.6.3 Temporary Connections. The
Administrative Authority may authorize
This provision is not to be interpreted as
temporary connection of the plumbing
requiring reinspection fees the first time a job is
equipment to the source of energy or fuel for the
rejected for failure to comply with the
purpose of testing the equipment.
requirements of this Code, but as controlling the
practice of calling for inspections before the job 103.7 Unconstitutionality
is ready for inspection or reinspection. 103.7.1 If any section, subsection, sentence,
Reinspection fees may be assessed when the clause, or phrase of this Code is, for any reason,
approved plans are not readily available to the held to be unconstitutional, such decision shall
inspector, for failure to provide access on the not affect the validity of the remaining portions of
date for which the inspection is requested, or for this Code. The Legislative Body hereby declares
deviating from plans requiring the approval of that it would have passed this Code, and each
the Administrative Authority. section, subsection, sentence, clause, or phrase
thereof, irrespective of the fact that any one or
To obtain reinspection, the applicant shall
more sections, subsections, sentences, clauses,
file an application therefor in writing upon a
and phrases be declared unconstitutional.
form furnished for that purpose and pay the
reinspection fee in accordance with Table 1-1. 103.8 Validity
In instances where reinspection fees have 103.8.1 If any provision of this Code, or the
been assessed, no additional inspection of the application thereof to any person or
work will be performed until the required fees circumstance, is held invalid, the remainder of
have been paid. the Code, or the application of such provision to
other persons or circumstances, shall not be
103.5.6.1 Corrections. Notices of
affected thereby.
correction or violation shall be written by
the Administrative Authority and may be 103.8.2 Wherever in this Code reference is made
posted at the site of the work or mailed or to an appendix, the provisions in the appendix
shall not apply unless specifically adopted.
7
Table 1-1 UNIFORM PLUMBING CODE
TABLE 1-1
Plumbing Permit Fees
Permit Issuance
1. For issuing each permit ...................................................................................................................*______
2. For issuing each supplemental permit.............................................................................................*______