Person in charge: *
Construction project:
Number:
Position: Date: 1/26/2017
Eccentric load
e x = 0.0 mm
e y = 0.0 mm
Anchor plate:
0.96
x = 100 mm
y = 104 mm
lx1 = 13.5 mm 8
0.4
lx2 = 13.5 mm
ly1 = 15.5 mm
ly2 = 15.5 mm sx1 sy1 z
df = 10 mm
Distance between anchors: x
h y
sx1 = 73 mm 2
sy1 = 73 mm 1 4
Edge distances: 3
without influence
Thickness of base material: ly1 lx2
h = 200 mm sy1 sx1
y ly2 lx1 x
[ kN, kNm ]
Drop-in Anchor E A4 M8x30
Design method B, ETAG 001, Annex C
approval for multiple use ETA-05/0116: MKT E
The anchorage is verified.
Maximum Load Anchor Boundary
load capacity bending conditions:
b[%] b[%] b[%]
1)
Static / quasi-static action 53.7 23.5 - OK
1)
No proof required.
The calculation applies if the hints on the last page are observed.
Design office: *
Person in charge: *
Construction project:
Number:
Position: Date: 1/26/2017
Required proofs
h h
Anchor loads: F Sd = 0.27 kN V Sd = 0.12 kN
Anchor 1 2 3 4
NSd [kN] 0.24 0.24 0.24 0.24
VSd [kN] 0.12 0.12 0.12 0.12
Vx,Sd [kN] 0.12 0.12 0.12 0.12
Vy,Sd [kN] 0.00 0.00 0.00 0.00
Installation parameters
Thread M = 8 mm
Diameter of drilled hole d0 = 10 mm
Depth of drilled hole h0(1) = 30 mm
Effective anchorage depth hef = 30 mm
Diameter of clearence hole in the fixture
selected df 10 mm
Tightening torque Tinst = 8 Nm
Width across nut SW = 13 mm
Remarks
The anchors are without influence of edge distance, if: c max ( 10 hef ; 60 d )
The selected diameter df of the clearance hole in the fixture does not meet the specifications in Table 4.1 in [1].
Therefore note the following:
a) Tension load: An additional washer is required and has to be verified by the engineer in charge.
b) Shear load: The gap between anchor and fixture shall be eliminated by other suitable means (e.g. sleeve) or
with round holes also by filling with mortar of sufficient compression strength.
Required strength class for the fastening screw or threaded rod: 70 (EN ISO 3506)
The application has to consist of at least 3 fixing points with at least one anchor.
The definition of multiple use according to the Member States is given in [3], Annex 1.
The design is based on the assumption that the anchor plate remains flat under the acting
forces.
The proof of the capacity of the anchor base component shall be shown according to chapter 7 in [1].