HowtoCalculateResinCapacityforSoftener|SofteningPlant?
PostedbyT.P.SivanandanonApril11th,2011|19Comments
Economical
SewageTreatment
sewagetreatmentPlantFor
Apartment&Independent
Houses.visitourwebsite!
ecotec.in
BeforetoCalculatethecapacityoftheWaterSoftener(softening)Plant,tochoosehowmuchwatertobesoftened.Inthiscase,100M3tobesoftened
at400ppmofFeedHardnessto5ppm.
HowtoCalculatetheresincapacity?
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 1/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
TheResinExchangeCapacityismentionintotheproductssupplierDataSheet*.
Normallycationicexchangecapacity:55/literofresin.
Hence,Literofresin=(FeedHardnessinppmXWaterQtyM3)/Exchangecapacity
=(400x100/55)=727literresinsufficient
HowtoCalculateSaltQuantity?
=110KgNaCl{?150GramNaCl/literofresin)
soquantityofwaterrequiretodilute@100%solution
=say344LiterWater{?320GramNaCl@20DegC/literofWater)
toget10%solutionadd3440literofwater
Now3784literishavingforregenerationandthatmuchofwatertobeinjected20Minute
thenstartbackwashprocesstoanother40minute
afterthatfastrinseuntilgethardnessis<5ppmonceitisreachednowtheplantisreadytostarttheprocess,itcanextractupto100m3
Feedpressuretobemaintainedup1.52Bar,
*Resignexchangecapacityisimportant,itisvaryproducttoproduct.
Youmightlike:
WhyDisinfectionProcessisImportantinWaterTreatmentPlant?
FindMassBalanceofYourSettlingTanks
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 2/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
Economical
SewageTreatment
sewagetreatmentPlantFor
Apartment&Independent
Houses.visitourwebsite!
ecotec.in
ArticlebySivanandan
T.P.Sivanandan
19Comments
1. Sphinxsays:
24/08/2012at5:18PM
HowtoCalculateSaltQuantity?
=150KgNaCl{?150GramNaCl/literofresin)
Istheabovecalcualtionwrong?
150GramNaClx727=109.05KgsofNaCl
PleasecorrectmeifIamwrong.
Reply
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 3/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
zenvsays:
31/12/2012at6:27AM
109.05kgsiscorrect,thankstopointit
Reply
Satishpalsays:
05/04/2016at5:52PM
howtoformulaofnewsoftenerdesign
Reply
2. Sphinxsays:
24/08/2012at5:23PM
AlsopleaseletmeknowwhatisthepurityofNaCLyouhaveconsideredintheabovecalculation
Reply
zenvsays:
31/12/2012at6:34AM
80to85%
Reply
3. Asadsays:
20/12/2012at1:26AM
Dearsir
Yourinformationmorehelpfulltotakeknowledge.
Reply
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 4/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
4. Jerrysays:
19/03/2013at6:48PM
pleasewatsthebestapproachtothisdesignquestion
Designawatersofteningplantforawaterworkhavingthefollowingdata:
Hardnessofwater=450mg/literasCaCo3
Availablehardnessaftertreatment=50mg/literasCaCo3
Quantityofwatertobetreated=25000liter/hour
Ionexchangecapacityofresintobeusedintheplant=10kgofhardness/cub.m
Saltrequiredforregenerationofresin=45kg/cub.moftheresin
Thewatersofteningplantworks2shiftsof8hoursperday.Assumeanysuitabledatawherenecessary.
thanku
Reply
5. Navinsays:
06/04/2013at12:09PM
Whatwouldbetheefficiencyofhardnessremovalwecouldexpect?Fromsay800ppmbythismethodhowmuchhardnesscanweremoveand
whatwouldbeleft?
Thanks
Navin
Reply
6. yethirajsays:
28/10/2013at6:47PM
WHATISTHEPRESSUREDROPFORUSING1000LPHSOFTENERBYUSING10X54(Dia.xHeight)withmultiportvalve.eg.inlet
pressureis2kg/cmsquare,whatistheoutputpressureaftersoftening
Reply
7. niteshsays:
03/01/2014at10:21AM
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 5/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
howtocalculatethehypodosinginwtp?????
Reply
8. MitangPatelsays:
20/02/2014at1:33PM
Whatwouldbetheefficiencyofhardnessremovalwecouldexpect?Fromsay800ppmbythismethodhowmuchhardnesscanweremoveand
whatwouldbeleft?
Reply
MitangPatelsays:
20/02/2014at1:47PM
ourflowrate30m3/hrandHardnesscalculateforresinis320ppm.Butinlethardnessisvaryfrom250ppmto700ppmandweusethe
softenervesselsis4872andresinqtyis1210ltr.andourObris200m3/hr.soafterregenerationwegothardnessonly20ppmbutparty
requiredlessthan5ppmso,whatwedo.
Reply
Md.AbuSayemsays:
21/07/2016at3:34PM
PleasemakeNaClsolutionbySoftWaterforregenerationandKeepAnotherSoftenervesselonthebasisof20ppmhardness.i
thinkitillsolvethisissue.
Reply
9. khurramShahzadsays:
07/06/2014at3:49PM
Wehave20m3/hrSoftenertankandourRawwaterhardness95ppmandTDS1080ppmKindlysuggesttherecipehowmuchresinrequired
andhowmuchNaClisrequiredforsoftenit?
Reply
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 6/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
KUNALKALEsays:
15/04/2015at11:26AM
DearkhurramShahzad,
Hardnessis95say100PPM.yourflowrateis20m3/hrtakeregenerationafterevery24hri.e.after480m3.becauseyourhardnessis
notmuch.
kgloadofCaCO3is48kg.i.e.ifwetakeexchangecapacityofresin55%resignrequirewillbe875lit.
NaClrequiredwillbe135kgforeachregeneration
Reply
10. Shanmugamsays:
17/12/2015at10:03AM
Dearsir,herewehad15m3/hrplant,ourrawwaterhave300ppmhardnessand800ppmtds,aftersofteningwegetresult5ppmbutwithinweek
gethighhardness,perdayfeed100m3.Ythishappening?
Reply
11. Mahedrakumarsharmasays:
24/04/2016at8:31AM
Aboveinformationincreasemyknowledgethankofallteam
Reply
12. Mahbubsays:
17/08/2016at3:37PM
Ineed30m3/hrsoftenerplant.Hardnessneedtoreducefro350ppmtolessthan5
1.Tanksize?
2.Resinquantity?
3.Saltforregenerationhowmuch?
Thanks
Mahbub
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 7/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
Reply
13. Pushkarsays:
26/09/2016at6:59AM
Howtocalculatedtheraisinquantitybasedontankcapacity.
Reply
0Trackbacks
LeaveaReply
Youremailaddresswillnotbepublished.Requiredfieldsaremarked*
Comment
Name*
Email*
Website
PostComment
RSS
Email
Facebook
Twitter
Google
Delicious
TogetFreeNewsletterEnteryouremailaddress:
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 8/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
Subscribe
SelectLanguage
Poweredby Translate
Categories
Alkalinity(1)
BasicPumpingCalculation(2)
BOD(9)
CalculationofCOD(2)
CalculationofNormality(4)
CalculationofTDS(3)
ChlorineDisinfection(2)
CoagulationFlocculation(1)
COD(6)
DisadvantageofRO(2)
HowDoesOzoneWorks(1)
Iron(1)
Manufacturers(3)
MembraneTreatmentTechnology(2)
MLSS(1)
pH(2)
ppm(1)
SDI(1)
Silica(1)
SilicaScaling(1)
TricklingFilterProcess(3)
Turbidity(1)
Ultrafiltration(1)
Uncategorized(39)
VariousProcessCalculations(1)
WasteWaterCalculation(11)
WasteWaterTreatment(27)
WasteWaterTreatmentProcess(8)
Wateranalysis(21)
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 9/10
2/28/2017 HowtoCalculateResinCapacityforSoftener|SofteningPlant?
WaterFiltration(3)
WaterHardness(1)
waterplantcaculation(2)
WaterPlantCalculation(14)
WaterQualityStandard(5)
WeightofWaterRelatedtotheWeightofAir(1)
WhatisDefinitions?(4)
WorkingPrincipleof(4)
EnteryourSearchTermhere Search
GoodNewsforGuest
WaterChemistryhappilyannounces,forourreaderrequestbase,weintroduceNewGuestArticlesubmissionpage.So,Don'twaitsubmityourpost
withgoodarticle.***ENJOY!***TogetmoreinfoClickhere
Copyright2010WaterChemistry|WaterTreatment|WaterRecyclingBlogAllrightsreserved PoweredbyWordPressThemebyTricksDaddy
http://www.waterchemistry.in/2011/04/howtocalculateresincapacityforsoftenersofteningplant/ 10/10