Вы находитесь на странице: 1из 2

DX-1710-2200-65-15.

5i-M
Model: A19451505 By HUAWEI

Electrical Properties
1710 - 2200
Frequency range (MHz)
1710 - 1880 1850 - 1990 1920 - 2170 2170 - 2200
Polarization +45 , -45
Electrical downtilt () 0 - 12 , continuously adjustable
0 6 12 0 6 12 0 6 12 0 6 12
Gain (dBi)
15.4 15.4 15.1 15.6 15.5 15.1 15.8 15.7 15.4 15.8 15.7 15.3

Side lobe suppression for first side 0 6 12 0 6 12 0 6 12 0 6 12


lobe above main beam (Typ.) (dB) 20 17 15 20 18 15 20 18 17 16 15 15
Horizontal 3dB beam width () 67 64 61 60
Vertical 3dB beam width () 13.9 13.0 12.6 11.5
VSWR < 1.5
Isolation between ports (dB) 30
Front to back ratio, copolar (dB) Typ. 29
0 Typ. 22
Cross polar ratio (dB)
60 Typ. 10
Max. power per input (W) 300 (at 50 ambient temperature)
Intermodulation IM3 (dBc) -153 (2 x 43 dBm carrier)
Squint () Avg. 1.5
Tracking (dB) Avg. 1.5 (within 10dB HBW)
Impedance () 50
Grounding DC Ground

Mechanical Properties
Antenna dimensions (H x W x D) (mm) 702 x 155 x 89
Packing dimensions (H x W x D) (mm) 1103 x 253 x 200
Antenna net weight (kg) 4.3
Bracket weight (kg) 2.6
Packing weight (kg) 8.8
Mechanical downtilt () 0 - 20
Mast diameter (mm) 50 - 115
Radome material Fiberglass
Radome colour Light grey
Operational temperature () -55 .. +65
Frontal: 150 (at 150 km/h)
Wind load (N) Lateral: 75 (at 150 km/h)
Rear side: 175 (at 150 km/h)
Max. operational wind speed (km/h) 150
Survival wind speed (km/h) 200
Connector 2 x 7/16 DIN Female
Connector position Bottom

1
DX-1710-2200-65-15.5i-M
Model: A19451505 By HUAWEI

34

46 34 Unit: mm

1710 - 2200
X

+45
-45

7/16 (F) 7/16 (F)

1710 - 2200 MHz

NOTE
Extraordinary operating conditions, such as heavy icing or storm wind, may result in the breakage of an antenna.
These facts must be considered during the site planning process.

The installation team must be properly qualified and also be familiar with the relevant national safety regulations.

Huawei Technologies Co., Ltd. Bantian, Longgang District, Shenzhen 518129, P.R.China www.huawei.com
Any previous datasheet issues become invalid. 2 Issue: 2012-10-10