Вы находитесь на странице: 1из 4

BASIC OCCUPATIONAL ENVIRONMENTAL ADVANCED SPECIAL

optimus red
Sound Level Meters for Noise at Work
& Occupational Noise Measurements

The optimus red sound level meters use the very latest digital technology and industrial design to give you
the ideal instrument for Occupational and Industrial Hygiene noise measurements.
Applications For Occupational Noise and Industrial Hygiene,
Occupational & Industrial Hygiene Noise measuring the noise exposure of employees
Evaluations quickly and reliably is essential. The optimus red
Noise at Work Surveys & Noise Exposure sound level meters are the ideal instrument for
Calculations these applications with a clear, high resolution
Hearing Protector Selection using HML or OLED colour screen, a wide 120dB measurement
Octave Band Methods span (up to 140dB(A) and 143dBC Peak) and
simultaneous measurement of all available
Machinery Noise Tests
parameters.
Noise Ordinance & Community Noise
Assessments Theres no setup or complicated configuration
needed. Just switch on, calibrate and press start.
General Noise Measurements
Its that simple.
Key Features
Simple operation with an ergonomic design VoiceTag audio recording

Simultaneous measurement of all workplace Before each measurement is made, you can
noise parameters with additional two virtual record a VoiceTag by simply speaking into the
noise meters microphone.
VoiceTag note recording You can record notes about the measurement
AuditStore measurement verification location, describe what is being measured or
Latest digital technology with a high resolution simply store information that may be useful at a
colour OLED display and back-lit keypad later date.
Measure up to 140dB(A) and 143dB(C) Peak The ideal instrument for any application
with a single measurement range
With two additional virtual noise meters running
Real-time 1:1 Octave Band Filters at the same time, you can meet any noise
NR & NC values & curves on screen regulation, guideline or standard.
Pause & Back Erase as standard Whether you need to meet the UK and EU
Very large 4GB memory which can store over Regulations, measure to OSHA HC & PEL, MSHA,
10,000 measurements ACGIH or any other regulation, an optimus red is
Long battery life the ideal instrument.
Measure up to 170dB with the optional
cr16x/05/12/r4EN
MV:200EH microphone system
Simple operation with advanced technology
The optimus sound level meters have youre wearing gloves.
been designed with ease of use as the The measurement data is displayed in a
most important feature which lets you clear and simple format along with a real-
get on with measuring and controlling time noise chart so that you can see how
the noise. the noise varies with time.
The instruments use the very latest in All of the functions of the instrument
digital technology and industrial design are measured simultaneously, and with
techniques to make everything as clear a wide 120dB measurement span you
and simple as possible. dont need to worry about choosing the
The high resolution colour OLED screen right range. An optimus can measure
can be seen in any conditions, and the up to 140dB(A) and 143dB(C) Peak in this
keypad illuminates automatically in low single range.
light. Just switch on, calibrate and you are
The case is robust and covered with ready to go.
a tactile finish so it can be used even if

The ideal solution for occupational noise


The optimus red sound level meters are the Once youve chosen the setup
ideal sound instruments for occupational noise needed it will be stored so each
and industrial hygiene measurements, as well time you use the meter you will
as for basic noise surveys, and will give you have the information you need.
all of the information you need, right at your For the two virtual noise meters,
finger tips. the LAVG, TWA, % Dose and Estimated
UK & EU Noise at Work Regulations % Dose are displayed.

If you are working to the UK Control of Noise Octave Band Filters for Noise
at Work Regulations or the EU Physical Agents Control & Selecting Hearing
(Noise) Directive, the Leq View gives you the Protection
information that you need. The CR:162C and CR:161C
The LAeq and LCPeak values are measured at the instruments also feature real-
same time which allow the LEP,d (LEX,8h) and the time octave band filters which will
Peak Action Levels to be determined. measure the noise in 10 different

The LCeq-LAeq (C-A) value is also measured frequency bands.


Class 1 & Class 2 performance
which can be used to select PPE using the HML The octave band measurement is made at the
Where precision measurements are needed,
method. LAE is also measured along with LZPeak same time as the other measurements and
Class/Type 1 instruments are available as
for regulations that use this rather than LCPeak. includes the overall level in each band along
well as the General Purpose Class/Type 2
OSHA,MSHA & other regulations with a time history of the bands across the
instruments.
measurement period.
If you need to meet regulations such as
Data logging & PC download
OSHA HC & NC, MSHA HC or ACGIH, the two NR & NC values & curves on screen
If there is a need to record and download
virtual noise meters in the Dose View can be The D variants add NR & NC values and curves
measurements to a PC, data logging is
quickly configured to provide you with this to the 1:1 octave band measurements.
available with the B, C & D version instruments.
information. This information can be useful in checking the
These units are supplied with the NoiseTools
The Quick Setup gives access to a number performance of HVAC systems and noise levels
software and a USB data cable to allow the
of preset functions including OSHA HC & NC, in rooms.
measurement information to be downloaded.
OSHA HC & ACGIH and MSHA HC & EC. Basic noise level measurements
The custom settings can be used to choose The optimus red instruments can also be
any other setup or configuration that you may used for basic noise measurements where the
need. Sound Level is required, such as community
and noise ordinance enforcement and testing
of fire and emergency alarms.
NoiseTools Software
The NoiseTools software package gives you a quick and simple way to Measurements can be sorted or
download, analyse and report your noise measurement information. grouped by any parameter, person,
The initial summary screen shows you the most commonly used place or project and measurement reports created quickly and easily.
information and, through simple icons, gives you access to the detailed NoiseTools is supplied free from any licensing restrictions or limits
measurement data. You can simply print the summary screen to get a allowing you to install the program on as many PCs as needed at no
quick measurement report. additional cost.
For advanced users, each and every function measured by the instrument
is available for review and analysis and the data can be exported for AuditStore data verification
further use. AuditStore is a new technology that helps you to ensure that your noise
VoiceTag audio recordings can be played back for reference and are measurement data is valid and trustworthy. AuditStore allows the user
automatically stored with the measurement data. Where Octave Band to verify measurements that have been downloaded to the NoiseTools
data is available, this information can be used by the program to calculate software against a secure data store within the instrument.
the level of protection from a range of hearing defenders and ear plugs. Each time you make a measurement with your optimus, a selection of the
To help you keep your noise measurement data organised and easy to overall data is stored into a separate, secure memory that is independent
find, NoiseTools allows each measurement to be allocated to people, of the main memory card.
places and projects. This data contains essential information about the measurement such as
the time, date and duration, the LAeq, Peak(C) and LAFmax, LA10 & LA90 (where
available) and the overload indication.
In addition to the noise measurement
data, information about the last
calibration is also stored.
The AuditStore data can be
downloaded from the instrument when required and then the
measurements can be checked against the AuditStore.
The NoiseTools software will check that the measurement information
held in the main database and displayed on the screen matches the
values within the AuditStore secure memory.
NoiseTools will display verification symbols if the information matches, a
unique feature which will be useful in any legal proceedings.

Instrument Range & Measurement Kits


The optimus red comprises the A, B, C and D variants, each of which Complete measurement kits are available for the optimus instruments
can be specified as either Class 1 or Class 2. All of the instruments can which contain the instrument, an acoustic calibrator, windshield, cables,
measure Sound Level functions plus Lmax and Lmin with all frequency batteries and accessories. The measurement kits contain all of the
and time weightings. accessories needed to carry out a noise survey.
The A versions measure the Integrated noise levels such as Leq and LAE,
C-A, Peak Sound Pressure and the virtual noise meters for OSHA/MSHA/
ACGIH.
The B versions provide the same functions as above but with the addition
of Data Logging so that measurements can be downloaded to the
NoiseTools software. The VoiceTag audio recording is available on the
B versions.
The C versions add Real Time Octave Band Filters to the functions of
the B versions which can be used for the selection of hearing protection.
The D variants add NR & NC values and curves directly on the instrument
display.
Specifications and a selection chart are available on the following page.
Specifications
Applicable Standards Measurement control Measurement Run Time
IEC 61672-1:2002 Class 1 or Class 2 Group X Pause & Back Erase with user selectable duration Integrators 2 & 3: TWA, Dose%, Est Dose%
IEC 60651:2001 Type 1 I or Type 2 I
IEC 60804:2000 Type 1 or Type 2 Dimensions Stored Functions
IEC 61252:1993 Personal Sound Exposure Meters Size: 283mm x 65mm x 30mm LXYMax & Time History of LXYMax
ANSI S1.4 -1983 (R2006), ANSI S1.43 - 1997 (R2007) Weight: 300gms/10oz LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak
ANSI S1.25:1991 Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
1:1 Octave Band Filters to IEC 61260 & ANSI S1.11-2004 (C & D variants) Batteries Integrators 2 & 3: LAVG , TWA. %Dose
4 x AA Alkaline Time History of LAVG
Microphone
Class 1 MK:224 pre-polarized, Class 2 MK:216 pre-polarized Battery life CR:162C & CR:161C
Typically 12 hours with Alkaline AA Displayed Functions
Microphone Preamplifier Typically 20 hours with Lithium AA Non-Rechargeable LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq
MV:200 Removable Preamplifier Battery life is dependent upon the battery type and quality & Graph of Short LAeq, LCPeak
screen brightness Measurement Run Time
Total Measurement Range: Integrators 2 & 3: TWA, Dose%, Est Dose%
20dB to 140dB RMS Single Range Connections Real-Time Octave Band Filters
Noise Floor: <18dB(A) Class 1, <21dB(A) Class 2 USB Type B to PC
AC & DC Output via ZL:174 (2 x Phono, 1m) Stored Functions
Frequency Weightings Multi-pin IO for external power via ZL:171 cable (2.1mm socket) LXYMax & Time History of LXYMax
RMS & Peak : A, C, & Z Measured Simultaneously External Power: 5v-15v via MultiIO socket via ZL:171 cable (2.1mm socket) LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak
Frequency Bands: 10 Octave Bands (31.5Hz to 16kHz, C & D variants) Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Tripod Mount Integrators 2 & 3: LAVG , TWA. %Dose
Time Weightings 1/4 Whitworth socket Time History of LAVG
Fast, Slow & Impulse Measured Simultaneously Octave Bands: Overall Leq & Leq Time History for each band
Case Measurement Run Time
Display Material: High Impact ABS-PC with soft touch back & keypad Time & Date of Measurement Start
High resolution OLED display. Ambient light sensor & illuminated keypad
Environmental CR:162D & CR:161D
Memory Temperature: Operating -10C to +50C, Storage -20C to +60C Displayed Functions
4GB (B, C & D Versions), 32GB factory fit option Humidity: Up to 95% RH Non Condensing LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq
Graph of Short LAeq, LCPeak
AuditStore Electromagnetic performance Measurement Run Time
Measurement verification data stored in secure memory IEC 61672-1:2002 & IEC 61672-2:2003 Integrators 2 & 3: TWA, Dose%, Est Dose%
Except where modified by EN 61000-6-1:2007 & EN 61000-6-1:2007 Real-Time Octave Band Filters
Time History Data Rates (Global settings) NR & NC values & curves
10ms, 62.5ms, 125ms, 250ms, 1/2 sec, 1 sec, 2 sec (User selectable) Language options
English, French, German, Spanish. Other language options may be available Stored Functions
VoiceTag Audio Recording (B, C & D Versions) LXYMax & Time History of LXYMax
Up to 30 seconds of audio notes with each measurement Software Support LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak
NoiseTools Download, Configuration & Analysis software supplied as Time History of LAeq, LCeq, LZeq, LCPeak, LZPeak, LAPeak, LAIeq
Integrators standard. Compatible with Microsoft Windows XP, Vista & 7 (32bit & 64bit) Integrators 2 & 3: LAVG , TWA. %Dose
Three simultaneous virtual noise meters. Integrator 1 is preset to Q3 for Time History of LAVG
Leq functions. Integrators 2 & 3 can be configured with the following: Measurement Functions Octave Bands: Overall Leq & Leq Time History for each band
Exchange Rate: 3, 4 or 5 dB CR:162A & CR:161A NR & NC values & curves
Threshold: 70dB to 120dB (1 dB steps) Displayed Functions Measurement Run Time
Time Weighting: None or Slow LXY, LXYMax, LXYMin, LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE Time & Date of Measurement Start
Criterion Level: 70dB to 120dB (1 dB steps) Graph of Short LAeq, LCPeak
Criterion Time: 1 to 12 hours in 1 hour steps Integrators 2 & 3: TWA, Dose%, Est Dose% where x=A ,C ,Z; y= F, S, I
Measurement Run Time Other functions may calculated by the NoiseTools software and displayed
Integrator Quick settings on download.
EU, OSHA HC & OSHA NC, OSHA HC & ACGIH, CR:162B & CR:161B
MSHA HC & MSHA EC, Custom 1 & Custom 2 Displayed Functions Notes
1. For details of the displayed and stored parameters, please refer to the optimus user
LXY, LXYMax, LXYMin,,LXeq, LCPeak, LZPeak, LCeq-LAeq, LXE, LAIeq
manual .
Graph of Short LAeq, LCPeak All specifications, features and values are typical and are subject to change without notice.

Instrument Selection
VoiceTag NR & NC
Function/ Sound Level Leq/Peak TWA/Dose Data Pause & 1:1 Octave Software
Class 1 Class 2 AuditStore Note Curves on Measurement Kit
Instrument Functions Functions Functions Logging Back Erase Band Filters Support
Recording screen
CR:162A CK:162A

CR:161A CK:161A

CR:162B CK:162B

CR:161B CK:161B

CR:162C CK:162C

CR:161C CK:161C

CR:162D CK:162D

CR:161D CK:161D
Standard Accessories Measurement Kits
The optimus sound level meters are supplied, as standard, with the following accessories: The optimus sound level meters are available as a complete measurement kit with the following accessories:
User Manual optimus Sound Level Meter
Certificate of Calibration CR:514 Class 2 or CR:515 Class 1 Acoustic Calibrator
USB Data/Power Cable UA:237 90mm Windshield
Windshield CK:300 Carrying Case
NoiseTools Software CD (Requires B, C or D Version to download measurements) User Manual & Certificates of Calibration
USB Data/Power Cable & NoiseTools Software CD (Requires B or C Version to download measurements)

Acoustic House
Bridlington Road
Hunmanby
North Yorkshire
YO14 0PH
United Kingdom ISO 14001:2004 ISO 9001:2008
EMS 552104 FM 531001
T: 0845 230 2434 (UK) Member
+44 1723 891655
F: +44 1723 891742
E: sales@cirrusresearch.co.uk BRITISH
SAFETY
cr16x/05/12/r4EN W: www.cirrusresearch.co.uk COUNCIL

Вам также может понравиться