ITEM

DESCRIPTION

ELEMENT NR. 1

SUBSTRUCTURE

EXCAVATION AND EARTHWORK (All Provisional)

Clear site to remove grasses, bush, shrubs and grubbing up their root including disposal

Excavate over site average 150mm deep to remove vegetable top soil

Excavate trench for foundation commencing from stripped level maximum depth not exceeding 1.00mm

Ditto pit for column base -do-

Backfill excavated materials around foundations

Remove surplus excavated material from site

Level and compact bottom of excavation to receive concrete.

Bed of approved Laterite filling well rammed and consolidated in layers to make up level (average depth of 600mm)

200mm Bed of approved hardcore filling with and including 40mm sand blinding spread and levelled and consolidated

Dieldrex' anti-termite solution to bottom and sides of excavation

CONCRETE WORK

Plain in-situ concrete


50mm thick Blinding plain in situ concrete (1:10) under column base

150mm thick plain insitu concrete (1:3:6/38mm aggregate) in Foundation footing

Reinforced In-Situ Concrete (1:2:4-20mm aggregate) filled into formwork and packed around reinforcement (both
measured separately ) in:
Column bases

Columns over 0.05 but not exceeding 0.10 square metre sectional area

150mm slab

Steps

COLLECTION
BAR REINFORCEMENT

High yield reinforcement to B.S. 4449 described including bends, hooks, tying wire, distance blocks or ordinary spacers.

12mm diameter bars in column base.

10mm diameter bars in isolated column.

16mm diameter bars in isolated column

FABRIC REINFORCEMENT

BRC mesh fabric reinforcement to B.S 1221 with 150mm end and sides laps laid on concrete slab well lapped at joint
and intersection. (measured net with no allowance made for laps

FORMWORK

Sawn formwork to:

Vertical sides of column bases

Edge of slab 150mm high

Steps 150mm high

BLOCKWORK

Hollow Sandcrete blockwork in cement mortar (1:6) filled solid with lean concrete 91:4:8) mix in:

150mm Wall

One layer 500mm guage polythene damp proof membrane laid on hardcore

Allow a provisional sum of 5,000.00 for additional work in substructure to be expended as directed by project engineer

Allow for protection of works carried out in this section

To collection

COLLECTION

Page Nr. 2/1

Page Nr. 2/2

SUBSTRUCTURE carried to summary


ELEMENT NR. 5
ROOF AND ROOF CONSTRUCTION

apprved corrugated 'zinc roofing sheets laid to slope with double corrugation side lap and fixed to hardwood purling at
700mm centres with and including galvanised drive screws and felt washers in accordance with manufacturer's printed
instructions (measured net: no allowance made for laps)

Timber carcasses

Sawn treated hardwood, building quality;


100 x 50mm rafters

150 x 50mm tie beams

150 x 50mm struts

100 x 50mm wall plate

75 x 50mm purling

150 x 50mm king post

50 x 50mm Noggings
300 x 25mm fascia board

Allow for protection of works carried out in this section

ROOF AND ROOF CONSTRUCTION TO SUMMARY

ELEMENT NR. 6

WALLS

Reinforced in-situ concrete (1:2:4-19mm


aggregate) as before described

Lintel

High Yield reinforcement bars to BS 4448


as before described (Provisional)

10 - 12mm diameter bar lintel

Sawn formwork to:

Sides and soffit of lintel

Hollow sandcrete blocks in cement


mortar (1:6)

150mm Wall
WALLS - Carried to Summary

ELEMENT NR. 7
DOORS AND WINDOWS
DOOR
METAL DOOR
Supply and fix purpose made Metal Door (Imported) complete with frame and architraves and all necessary ironmongery
fixed to Blockwork and concrete work.
Size 750 x 2100mm

WINDOW

Aluminium Windows

Supply and fix the following Standard powder coated 'Tower Aluminium' window complete with frame, 5mm sand
blasted glass and locking handle fixed to concrete and block works

Ditto size 600mm x 1000mm high -do-

Burglar Proofing

Fabricate and fix mild steel burglary proof to window executed complete to Architect's later detail

PROTECTION

Protect all work in this section

DOORS AND WINDOWS -carried to Summary


ELECTRICAL INSTALLATION

Allow PC Sum of N..... For electrical installation to be executed directed by Electrical Engineer with
design

Allow for Profit

Allow for Attendance

BUILDERS WORKS

Allow for all necessary cutting, chases, mortice and forming holes through structure of building and grouting up and
making good in cement mortar in connection with Electrical installation

Allow for protection of works carried out in this section

ELECTRICAL INSTALLATION TO SUMMARY

MECHANICAL INSTALLATION

Allow provisional sum of N..... For Mechanical linstallation to be executed directed by


Mechanical Engineer with design

Allow for Profit

Allow for Attendance

BUILDERS WORKS
Allow for all necessary cutting, chases, mortice and forming holes through structure of building and grouting up and
making good in cement mortar in connection with Mechanical Installation

Allow for protection of works carried out in this section

MECHANICAL INSTALLATION TO SUMMARY


CEILING, WALL AND FLOOR FINISHINGS

CEILING FINISHES

INTERNAL WORKS

WALL FINISHES

12mm cement and sand (1:4) rendering on wall (INTERNAL and EXTERNAL)

Ditto on isolated columns

Ditto on sides and soffit of beam girth not exceeding 900mm

6mm thick white glazed ceramic wall tiles fixed to screeded backing (measured net with approved adhesive) on

Wall

12mm Cement and sand (1:4) screeded backing on wall

FLOOR FINISHES

TILE WORK

8mm vitrified floor tiles laid on screeded bed (measured net) including grouting joints in white cement mortar on:

Beds and Backings

Cement and sand (1:4)


42mm thick Screeded bed in cement mortal (1:3)

ditto skirting

Allow for protection of works carried out in this section

CEILING WALL AND FLOOR FINISHING TO SUMMARY

PAINTING AND DECORATING

Prepare and apply POP screeding and coat of TEXTURE FINISHEDof approved paint

Rendered soffit

Rendered wall (internal and external)

Ditto-reveal not exceeding 300mm

Ditto on isolated columns


Ditto on sides and soffit of beam girth not exceeding 900mm

Allow for protection of works carried out in this section

PAINTING AND DECORATING TO SUMMARY


S U M MARY

SUBSTRUCTURE

ROOF AND ROOF CONSTRUCTION

WALL

DOORS AND WINDOWS

ELECTRICAL INSTALLATION

MECHANICAL INSTALLATION

CEILING, WALL & FLOOR FINISHINGS

PAINTING AND DECORATING

MAIN BUILDING
TO GENERAL SUMMARY
QTY UNIT RATE AMOUNT

m2 75 -

23 m2 80 1,840.00

7 m3 650 4,550.00

1 m3 650 650.00

6 m3 200 1,160.00

1 m3 300 300.00

16 m2 60 960.00

10 m3 1,700 17,000.00

- m2 900 -

16 m2 50 800.00

3 m2 900 2,700.00

2 m3 23,500 37,600.00

0 m3 24,000 10,800.00

0 m3 24,000 4,800.00

2 m3 24,000 48,000.00

- m3 24,000 -

131,160.00
2 kg 235 470.00

2 kg 235 470.00

- kg 235 -

- m2 650 -

3 m2 1,300 3,900.00

23 m 195 4,485.00

- m 195 -

27 m2 2,400 64,800.00

23 m2 150 3,450.00

sum 5,000.00

item

82,575.00

131,160.00

82,575.00

213,735.00
1 m2 50,000 25,000.00

31 m 380 11,780.00

- m 380 -

- m 380 -

17 m 380 6,460.00

62 m 250 15,500.00

- m 380 -

m 120 -
- m 430 -

item

58,740.00

1 m3 24,000 16,800.00

4 kg 235 940.00

9 m2 1,300 11,700.00

78 m2 2,400 187,200.00
216,640.00

6 Nr 15,000 90,000.00

6 No 7,125 42,750.00

6 m2 2,000 12,000.00

144,750.00
sum 30,000.00

Sum

sum

item

30,000.00

sum 90,000.00

Sum
sum

item

86,690.00
86 M2 600 51,600.00

1 M2 600 600.00

1 M2 600 720.00

44 M2 2,200 96,800.00

8 m2 600 4,800.00

23 M2 2,400 55,200.00

23 m2 500 11,500.00

9 m 75 675.00

item

221,895.00

1 M2 500 500.00

86 M2 300 25,800.00

1 M 150 150.00

1 M2 500 500.00
1 M 500 600.00

item

27,550.00
213,735.00

58,740.00

216,640.00

144,750.00

30,000.00

86,690.00

221,895.00

27,550.00

1,000,000.00