SVE BULLETIN
SPECIAL VEHICLE ENGINEERING BODY BUILDERS ADVISORY SERVICE
E-Mail via Website: www.fleet.ford.com/truckbbas (click "Contact Us")
Toll-free: (877) 840-4338
QVM Bulletin: Q-252 Date: 08 August, 2016

2017 and later F-Series Super Duty Upfitter Switches


Models Affected: 2017 to present model year F-250/350/450/550 Super Duty Trucks with optional Upfitter
Switches
Description:

The Ford Upfitter Switches are optional overhead console mount switches (Option Code 66S) that control
under hood mounted relays. These relays power six blunt cut wires that are taped on a harness near the
upfitter auxiliary relay box that can be found on the drivers side of the engine compartment. The six blunt
cut wires are as follows:

Switches Circuit Color Fuse # Rating


Aux 1 CB117 Brown / Green F10 25A
Aux 2 CB114 Violet / Orange F9 25A
Aux 3 CB116 Blue / Green F8 25A
Aux 4 CB113 Gray / Brown F7 25A
Aux 5 CB115 Brown / Blue F1 40A
Aux 6 CB118 Gray / Orange F2 40A

In addition to the upfitter switch blunt cut wires, this bundle contains the following blunt cut circuits:

Description Circuit Color Fuse # Rating


Run/ Start Output CB111 Brown F3 20A
Battery Hot Output SB106 Brown / Red F6 20A
PTO Relay Control CE924 Blue / Green N/A N/A
PTO Relay Output CB112 Green / White F5 25A

All relays and fuses are located in the upfitter relay box.

Figure 1: 2017 Super Duty Upfitter switch location

NOTE: Upfitter Switches cannot be added to a vehicle that was not built with this option at production.
Originator: BBAS Date Issued: 08/08/16
Document: SVE Bulletin No. Q-252 Page 1 of 5
To find the bunt cut wires:
1. Open Hood
2. Locate the relay pack on the Left hand side (drivers side) of the engine compartment (see Fig. 2).
3. Locate bundle of 10 blunt cut wires with shrink wrap on the harness near the relay pack.

Upfitter Relay Box & blunt cut circuit access

Figure 2: Upfitter Relay Box and upfitter switch blunt cut output location.

Accessing blunt cuts wires:


On vehicles with dual batteries, removing the upfitter relay box will provide additional access to the blunt cut
wires.

1. Disconnect the electrical connector.


2. Release tabs and lift upwards to remove.

To reinstall upfitter relay box:

1. To install, reverse the removal procedure.

Configuring Upfitter Switches 5 and 6 to Hot-at-all times.

Upfitter relay box fuse F4 (5A) can be put into one of two positions. In Position A, auxiliary switch 5 and 6,
operate with the ignition in RUN or START. In Position C, auxiliary switch 5 and 6 operate hot at all times.

The following procedure describes how to configure #5 and #6 upfitter switches to Battery hot.

1. Remove upfitter relay box cover.


2. Remove 5 Amp fuse located on the lower right hand corner of the upfitter relay box.
3. Slide the contact guard from position A (left) to position C (right) position.
4. Re-insert 5 Amp fuse into position C (right) position.
5. Replace relay box cover.

Fuse F4
Figure 3: Fuse F4 location

Originator: BBAS Date Issued: 08/08/16


Document: SVE Bulletin No. Q-252 Page 2 of 5
Wiring Schematics

Hot at all times Hot in Run or Start


BATTERY BODY
JUNCTION CONTROL
MEGA BOX (BJB) F22 MODULE (BCM)
200A 11-1 5A 11-4
13-10 13-19

1 C1617C
BU-RD 23 C2280C
SBF03

CBP22 GN-OG S352 C315 - 12 CBP22 GN-OG S208

GN-OG
C3271A

CBP22
UPFITTER
RELAY
F4 C F4 A BOX
5A 11-6
13-10 13-10 151-16
1 C9805
NOTE:

GN-OG
CBP22
Either F4-A or F4-C can be
installed but not both at the same time.
Upfitter relay box shipped with fuse
in AUX F4A position. 11 C9120

UPFITTER
SWITCH
GN-RD
SB104

151-16

5 C315
SB104 GN-RD C9805- 8 C9120
5

7 8 9 10 6 4 3 C9120

BU-OG
CAC14
YE-OG
CAC13

CAC08

CAC07

CAC06
GN-BN
CAC05

GD233
VT-GN
BN

YE

BK
2 3 7 10 9 4 12 C9805

GD233 BK
F E D C B A

140-11 140-11 140-11 140-10 140-10 140-10

TO UPFITTER RELAY BOX


G201
10-12

Hot at all times Hot in Run or Start


BATTERY BODY
JUNCTION CONTROL
MEGA BOX (BJB) F22 MODULE (BCM)
200A 11-1 5A 11-4
13-10 13-19

1 C1617C 23 C2280C
GN-OG
CBP22
BU-RD
SBF03

CBP22 GN-OG S352 C315 - 12 CBP22 GN-OG S208

CBP22 GN-OG

1 C3271A
UPFITTER
RELAY
F4 C F4 A BOX
5A 11-6
13-10 13-10 UPFITTER UPFITTER 151-16
1 3 RUN/START 1 3 PTO
RELAY RELAY
F6 2 5 F3 2 5 F5
20A 25A 25A
13-10 13-10 13-10
GD233 BK

CB112 GN-WH

NOTE:
CE924 BU-GN
SB106 BN-RD

SB103 SB105
Either F4-A or F4-C can be
CB111 BN

installed but not both at the same time. BU-RD GY-RD


Upfitter relay box shipped with fuse
in AUX F4A position.

S353

CUSTOMER CUSTOMER
ACCESS 1 C315 ACCESS
located behind located behind CUSTOMER
upfitter relay box upfitter relay box
GD233 BK

ACCESS
Hot at all times Hot in Start or Run located behind
upfitter relay box

G201
10-12

Originator: BBAS Date Issued: 08/08/16


Document: SVE Bulletin No. Q-252 Page 3 of 5
Wiring Schematics (Cont.)

TO UPFITTER SWITCHES
Hot at all times
BATTERY
JUNCTION
MEGA BOX (BJB)
200A 11-1 140-8 140-8 140-8
13-10
A B C
1 C1617C
SBF03 BU-RD

6 9 3 C315

CAC06 GN-BN

CAC07 VT-GN
CAC05 YE

1 C3271A
UPFITTER
RELAY
BOX
11-6
UPFITTER UPFITTER UPFITTER 151-16
1 3 RELAY 1 1 3 RELAY 2 1 3 RELAY 3

2 5 F10 2 5 F9 2 5 F8
25A 25A 25A
13-10 13-10 13-10
CB117 BN-GN

CB116 BU-GN
CB114 VT-OG
SB110 YE-RD

SB108 VT-RD
SB109 RD
GD233 BK

GD233 BK

GD233 BK
CUSTOMER CUSTOMER CUSTOMER
ACCESS ACCESS ACCESS
located behind located behind located behind
upfitter relay box upfitter relay box upfitter relay box
GD233 BK
S353 GD233 BK

1 C315
GD233
BK

G201
10-12

Hot at all times TO UPFITTER SWITCHES


BATTERY
JUNCTION
MEGA BOX (BJB)
200A 11-1 140-8 140-8 140-8
13-10

D E F
1 C1617C
SBF03 BU-RD

4 11 10 C315
CAC13 BU-OG

CAC14 YE-OG
CAC08 BN

1 C3271A
UPFITTER
RELAY
BOX
11-6
UPFITTER UPFITTER UPFITTER 151-16
1 3 RELAY 4 1 3 RELAY 5 1 3 RELAY 6
F7 F1 F2
2 5 25A 2 5 40A 2 5 40A
13-10 13-10 13-10
SB107 WH-RD

CB118 GY-OG
CB113 GY-BN

CB115 BN-BU

SB102 YE-RD
SB101 RD
GD233 BK

GD233 BK

GD233 BK

CUSTOMER CUSTOMER CUSTOMER


ACCESS ACCESS ACCESS
located behind located behind located behind
upfitter relay box upfitter relay box upfitter relay box

GD233 BK
S353 GD233 BK

1 C315
GD233
BK

G201
10-12

Originator: BBAS Date Issued: 08/08/16


Document: SVE Bulletin No. Q-252 Page 4 of 5
Relay and Fuse diagram

UPFITTER RELAY BOX

F2 F1
F3

F4C

F10 F9 F8 F7 F6 F5
UPFITTER
UPFITTER RUN/START
PTO RELAY F4A
1 3 1 3 RELAY

UPFITTER
5 2 5 2 RELAY 2
Fuse Amps Circuits protected
3 2 1 3
F1 40 Upfitter relay 5

5 5
UPFITTER F2 40 Upfitter relay 6
5 RELAY 4
UPFITTER
RELAY 5 F3 25 Upfitter run/start relay
1 2 3 1 2
F4A or F4C 5 Upfitter switch

F5 25 Upfitter PTO relay


3 2 1 3
F6 20 Customer access
5 5 5
UPFITTER F7 25 Upfitter relay 4
RELAY 6 UPFITTER
1 2 3 1 2 RELAY 3 F8 25 Upfitter relay 3
F9 25 Upfitter relay 2
F10 25 Upfitter relay 1

UPFITTER
RELAY 1

Originator: BBAS Date Issued: 08/08/16


Document: SVE Bulletin No. Q-252 Page 5 of 5