SVE BULLETIN
SPECIAL VEHICLE ENGINEERING BODY BUILDERS ADVISORY SERVICE
E-Mail via Website: www.fleet.ford.com/truckbbas (click "Contact Us")
Toll-free: (877) 840-4338
QVM Bulletin: Q-252 Date: 08 August, 2016
The Ford Upfitter Switches are optional overhead console mount switches (Option Code 66S) that control
under hood mounted relays. These relays power six blunt cut wires that are taped on a harness near the
upfitter auxiliary relay box that can be found on the drivers side of the engine compartment. The six blunt
cut wires are as follows:
In addition to the upfitter switch blunt cut wires, this bundle contains the following blunt cut circuits:
All relays and fuses are located in the upfitter relay box.
NOTE: Upfitter Switches cannot be added to a vehicle that was not built with this option at production.
Originator: BBAS Date Issued: 08/08/16
Document: SVE Bulletin No. Q-252 Page 1 of 5
To find the bunt cut wires:
1. Open Hood
2. Locate the relay pack on the Left hand side (drivers side) of the engine compartment (see Fig. 2).
3. Locate bundle of 10 blunt cut wires with shrink wrap on the harness near the relay pack.
Figure 2: Upfitter Relay Box and upfitter switch blunt cut output location.
Upfitter relay box fuse F4 (5A) can be put into one of two positions. In Position A, auxiliary switch 5 and 6,
operate with the ignition in RUN or START. In Position C, auxiliary switch 5 and 6 operate hot at all times.
The following procedure describes how to configure #5 and #6 upfitter switches to Battery hot.
Fuse F4
Figure 3: Fuse F4 location
1 C1617C
BU-RD 23 C2280C
SBF03
GN-OG
C3271A
CBP22
UPFITTER
RELAY
F4 C F4 A BOX
5A 11-6
13-10 13-10 151-16
1 C9805
NOTE:
GN-OG
CBP22
Either F4-A or F4-C can be
installed but not both at the same time.
Upfitter relay box shipped with fuse
in AUX F4A position. 11 C9120
UPFITTER
SWITCH
GN-RD
SB104
151-16
5 C315
SB104 GN-RD C9805- 8 C9120
5
7 8 9 10 6 4 3 C9120
BU-OG
CAC14
YE-OG
CAC13
CAC08
CAC07
CAC06
GN-BN
CAC05
GD233
VT-GN
BN
YE
BK
2 3 7 10 9 4 12 C9805
GD233 BK
F E D C B A
1 C1617C 23 C2280C
GN-OG
CBP22
BU-RD
SBF03
CBP22 GN-OG
1 C3271A
UPFITTER
RELAY
F4 C F4 A BOX
5A 11-6
13-10 13-10 UPFITTER UPFITTER 151-16
1 3 RUN/START 1 3 PTO
RELAY RELAY
F6 2 5 F3 2 5 F5
20A 25A 25A
13-10 13-10 13-10
GD233 BK
CB112 GN-WH
NOTE:
CE924 BU-GN
SB106 BN-RD
SB103 SB105
Either F4-A or F4-C can be
CB111 BN
S353
CUSTOMER CUSTOMER
ACCESS 1 C315 ACCESS
located behind located behind CUSTOMER
upfitter relay box upfitter relay box
GD233 BK
ACCESS
Hot at all times Hot in Start or Run located behind
upfitter relay box
G201
10-12
TO UPFITTER SWITCHES
Hot at all times
BATTERY
JUNCTION
MEGA BOX (BJB)
200A 11-1 140-8 140-8 140-8
13-10
A B C
1 C1617C
SBF03 BU-RD
6 9 3 C315
CAC06 GN-BN
CAC07 VT-GN
CAC05 YE
1 C3271A
UPFITTER
RELAY
BOX
11-6
UPFITTER UPFITTER UPFITTER 151-16
1 3 RELAY 1 1 3 RELAY 2 1 3 RELAY 3
2 5 F10 2 5 F9 2 5 F8
25A 25A 25A
13-10 13-10 13-10
CB117 BN-GN
CB116 BU-GN
CB114 VT-OG
SB110 YE-RD
SB108 VT-RD
SB109 RD
GD233 BK
GD233 BK
GD233 BK
CUSTOMER CUSTOMER CUSTOMER
ACCESS ACCESS ACCESS
located behind located behind located behind
upfitter relay box upfitter relay box upfitter relay box
GD233 BK
S353 GD233 BK
1 C315
GD233
BK
G201
10-12
D E F
1 C1617C
SBF03 BU-RD
4 11 10 C315
CAC13 BU-OG
CAC14 YE-OG
CAC08 BN
1 C3271A
UPFITTER
RELAY
BOX
11-6
UPFITTER UPFITTER UPFITTER 151-16
1 3 RELAY 4 1 3 RELAY 5 1 3 RELAY 6
F7 F1 F2
2 5 25A 2 5 40A 2 5 40A
13-10 13-10 13-10
SB107 WH-RD
CB118 GY-OG
CB113 GY-BN
CB115 BN-BU
SB102 YE-RD
SB101 RD
GD233 BK
GD233 BK
GD233 BK
GD233 BK
S353 GD233 BK
1 C315
GD233
BK
G201
10-12
F2 F1
F3
F4C
F10 F9 F8 F7 F6 F5
UPFITTER
UPFITTER RUN/START
PTO RELAY F4A
1 3 1 3 RELAY
UPFITTER
5 2 5 2 RELAY 2
Fuse Amps Circuits protected
3 2 1 3
F1 40 Upfitter relay 5
5 5
UPFITTER F2 40 Upfitter relay 6
5 RELAY 4
UPFITTER
RELAY 5 F3 25 Upfitter run/start relay
1 2 3 1 2
F4A or F4C 5 Upfitter switch
UPFITTER
RELAY 1