Академический Документы
Профессиональный Документы
Культура Документы
INSIDE
OCTOBER 2014
2
TX HOME
3
BESTIL P TELEFON: 1 800.000.0000
TABLE OF CONTENTS
TX 64
Main components 5
Functional Diagram / Functional Description 6
Technical specifications 7
Heat exhanger 8
Heat exhanger 9
Dimensional drawing 10
Mounting demo 11
TX 35A
Main components 12
Operating principle 13
Technical specifications 14
Dimensional drawing 15
TX 75A
Main components 16
Operating principle 17
Technical specifications 18
Heat exhanger 19
Dimensional drawing 20
Location 21
TX 350A
Main components 22
Operating principle 23
Technical specifications 24
Heat exchanger 25
Dimensional drawing 26
TX HomeVex
Main components 27
Functional Diagram / Functional Description 28
Technical specifications 29
Energy Consumption SEL Values / Heat recovery 30
Energy Consumtion / Basis Of Calculation 31
Heat exchanger 32
Dimensional drawing 33
Standard / Option 34
4
TX 64
MAIN COMPONENTS
1 Murgennemfring
2. Forlngerstykke
3 3. Unit
4. Adapter
5
FUNCTIONAL DIAGRAM
FUNCTIONAL DESCRIPTION
Thefreshair(1)isdrawnthroughthefilter(3)andheatrevoceryunit(5)bythefan(6),andthensuppliedto
theroom(8).Theindoorair(9)isdrawnbythefan(11)througtfilter(10)andheatrecoveryunit,andisthe
blowntotheoutside(12).
Ifthetemperature(T)exceedsapresetvalue,therota onoftheheatrecoveryunitwillstop,whichisillustra-
tedbythebypassdamper(4).Ifthepressure(P)islowerthanapresetvalue,aredlightemi ngdiodewill
becomeac vated.Thisindicatesacloggedfilter.
6
TECHNICAL SPECIFICATIONS
Dimensions outside part: 220 x 122 mm
Capacity: 64 m/h
Temperature efficiency: 70 %
Filter: M5
Weight: 4 kg
Sound: 32 db(A)
Duct: 1 x 180
Vout 2,7 2,8 2,9 3,0 2,7 2,8 2,9 3,0 2,7 2,8 2,9 3,0
m3/h 32 48 64 74 25 40 49 62 20 36 45 54
dB(A) 28 30 32 35 28 30 32 35 28 30 32 35
W 4,2 4,7 5,5 6,7 4,2 4,7 5,4 6,5 4,2 4,8 5,3 6,3
J/m 473 353 309 326 605 423 397 377 756 480 424 420
t 76% 74% 70% 68% 76% 76% 74% 71% 75% 76% 74% 73%
7
HEAT EXCHANGER
8
HEAT EXCHANGER
9
DIMENSIONAL DRAWING
10
MOUNTING DEMO
Outside Inside
11
TX 35A
MAIN COMPONENTS
3
2
1. Exchanger
1
2. Inside unit
3. Outside unit
4. Extension pipe
5
4 125 (500 mm) - option
5. Extension pipe
160 (500 mm) - option
12
OPERATING PRINCIPLE
TX 35A consists of an inner and outer casing and a duct in the form of an aluminium heat ex-
changer. The unit replaces indoor air by fresh outdoor air and thereby improves the indoor cli-
mate.
The aluminium heat exchanger (6) utilises warm indoor heat to heat up the fresh outdoor air. The
heat exchanger's function is heat recovery.
The air supply motor (5) creates inflow of fresh outdoor air through the exchanger (6) and the
insect net (10), leading the inflow through a filter (3) and further through the air supply grate (1)
and out into the room.
The exhaust fan (11) leads the indoor air through the filter (4) and the exchanger (6) and further
through the air exhaust grate (7) to the outdoor.
Outside
Inside
Aluminium heat exchanger
13
TECHNICAL SPECIFICATIONS
Dimensions L x W x D: 300x250x110mm
Temperature efficiency: 65 %
Weight: 14 Kg
Duct: 1 x 170
14
DIMENSIONAL DRAWING
HEAT EXCHANGER
INSIDE UNIT
OUTSIDE UNIT
15
TX 75A
MAIN COMPONENTS
16
OPERATING PRINCIPLE
The purpose of the ventilation system is to achieve a better indoor air quality. The TX 75A has two
fans which, through a heat exchanger, supplies the same amount of air as is extracted. The purpo-
se of the heat exchanger is to heat the colder supply air by transferring heat from the hotter ex-
haust air, minimizing the heat loss by approximately 85 percent.
The airflow can be regulated by a CO2 sensor (optional), which ensures a proper air exchange in
relation to the room activity.
The outdoor air is drawn into the inlet fan and blown through the filter. Then the air moves through
the heat exchanger and the supply air diffuser distributes the air into the room.
The indoor air is extracted through filter and heat exchanger by the exhaust fan. The exhaust air is
then blown outdoor.
Diffuserin
Filter
Heat exchanger
Diffuser out
Inlet fan
Filter
Exhaus fan
17
TECHNICAL SPECIFICATIONS
Dimensions W x D x H: 180x336x1200 mm
Capacity: 75 m/h
Temperature efficiency: 88,1 %
Filter (standard): M5
Filter (option): F7
Weight: 17 kg
Electric power connection: 1 ~ 230 V / 50Hz
Effect (fans): 2 x 82 W
Electric reheater: Not available
Standby Mode A Mode B Forced
Sound level db[A] - 30 35 47
Flow [m/h] - 50 75 135
18
HEAT EXCHANGER
19
DIMENSIONAL DRAWING
The unit's external dimensions
20
LOCATION
Mounting screws
21
TX 350A
MAIN COMPONENTS
10
1
10
3
11 12 3 2
7
22
OPERATING PRINCIPLE
The unit has a built-in counter flow heat exchanger and two balanced EC motors. The fans extract
air from the room while supplying fresh air from outdoors. The heat exchange utilizes the heat of
the return air for heating the cooler fresh air.
Airflow:
The air supply fan (1) draws in fresh outdoor air through the filter (3), 3
heat exchanger (2), and out the diffuser at the top into the room.
The exhaust fan (4) draws in air from the grills in the bottom and si-
des, through the filter (5), through the heat exchanger (2), and then
blow it out in the return channel in the back.
Bypass:
When opening the bypass damper (6), the return air will bypass the 2
heat exchanger. Therefore the outdoor air supplied to the room will
not be heated.
5
Control:
At the control panel (7) you can set the desired temperature of the
supply air. A sensor detects the current temperature of the inlet air,
and if this is lower than the set value, the controller will slow down 6
the air supply fan. This causes a better heat exchanger efficiency and
consequently warmer supply air.
23
TECHNICAL SPECIFICATIONS
Dimensions W x D x H: 662x336x1400 mm
Filter (option): F7
Weight: 47 kg
Effect (fans): 2 x 82 W
Sound level db - 30 35 56
24
HEAT EXCHANGER
25
DIMENSIONAL DRAWING
Outside Area of intake
Area of exhaust
26
TX HomeVex
MAIN COMPONENTS
6 9
3 13 13
15 8
2 1
7
14
12
4
11 10
13 13 5
27
FUNCTIONAL DIAGRAM
2
5 14
4
1 3 13 12
T1 T3
T4 T2
18
11
15 6 8 9
16 10
17
FUNCTIONAL DESCRIPTION
28
TECHNICAL SPECIFICATIONS
Dimensions H x W x L 1200x600x300mm
29
ENERGY CONSUMPTION
SEL Values
Heat recovery
30
ENERGY CONSUMPTION
31
HEAT EXCHANGER
32
DIMENSIONAL DRAWING
33
STANDARD / OPTION
TX 35A TX 75A TX 350A TX HomeVex
TX Electronic Kontrol panel
Hygrostat
PIR sensor
LON Interface
M5 filter
F7 filter
Grease filter
Tubes
Condensate pump
Condensate try
Automatic by-pass
Modulating by-pass
External motordamper
Reheater
Preheater
Water heater
Mounting bracket
Standard
Option
Not possible
34
r a d
f fe a n
e o gh
W lpin t
he en i to .
w h me s i r . .
co sh a
fre
35
Turbovex A/S Tel. +45 96 98 14 62
Industrivej 45 info@turbovex.dk
DK-9600 Aars www.turbovex.dk
36