Вы находитесь на странице: 1из 8

Design Calculations for Circular Concrete Tanks w/o Prestressing

Project: Checked by:


Designer:
Date: 3/16/2017 Date:

Input Design Data


Inside tank diameter (feet) ? 90.0 (Maximum 120-foot diameter)
Tank wall height (feet) ? 12.0 (Maximum 14-feet tall)
ertight wall to ring foundation joint (method)?
dditional 1/4" x 6" steel plate required (feet) ? 0.0 (Other than at the wall to ring foundation
Select radial steel (Asr) bar size ? (Asv spacing greater than 9'' use #4 bars
ngth for radial steel in footing and wall (feet) ? (Optional, generally bar lengths are 20 fe
ace floor slab monolithically with wall footing ? (If no, footing assumed to be isolated fro
ce from footing edge to tile centerline (feet) ? 0.5 (4" tile diameter)
Length of tile outlet (feet) ? 200.0 (4" tile diameter)
Distance from wall centerline to fence (feet) ? 5.0
Input other concrete used in project (sq.ft) ? 320.0 (unloading slabs, etc.)
Thickness of other concrete (inches) ? 6.0
Extra concrete delivered to site (percent) ? 0.0 (Safety factor, applied to each concrete q
Extra steel delivered to site (percent) ? 0.0 (Safety factor, applied to steel total lengt
Select desired floor slab joint spacing (feet) ? 90 (A joint is assumed between footing and
Select grade of floor steel (ksi) ? (Note: this only applies to the floor steel
Excavation quantity (cu.yd.) ? 0.0 wall and footing steel shall be
Subgrade fill quantity (cu.yd.) ? 0.0
Backfill quantity (cu.yd.) ? 0.0
Drain fill quantity (cu.yd.) ? 0.0
Number of concrete chairs ? 0.0
Other: Other Quantity 0.0 Lin. Ft.

Tank Design Information


Floor Slab Thickness (inches) = 5
Wall Thickness (inches) = 10
Footing Width (inches) = 48 (Required soil bearing pressure = 2000
Footing Thickness (inches) = 12
Footing Overhang (inches) = 14
Concrete Compressive Strength (f 'c, psi) = 4000 (Required strength for all concrete)
Footing Radial Steel (As1) = #4 @ 8.0" (Place radial steel on top of ring steel)
Footing Ring Steel (As2) = #4 @ 6" (Place ring steel 3 inches above footing
Wall Vertical Steel (Asv) = #4 @ 8" (Place vertical steel on the outside of th
Wall Ring Steel (Asr) = #4 @ 6" (Ring steel must be placed in the center
Tie Bar Steel = #4 @ 8" (Secure all tie bars to footing radial stee
Floor Slab Steel (Floor Steel) = #4 @ 12"
Floor Steel Splice Length (inches) = 20
Wall Ring Steel Splice Length (inches) = 20
oting Ring Steel Splice Length (inches) = 20
Tank Capacity (ft3) = 63617 (Assuming 1-ft. freeboard, 6-in. sedimen

Written by: NRCS Design Staf


Federal Building
210 Walnut St., Ste. 693
Des Moines, IA 50309-2180
ks w/o Prestressing

63617
0-foot diameter) 56562
-feet tall)
4
t the wall to ring foundation joint) 1
greater than 9'' use #4 bars at 1/2 Asv)
nerally bar lengths are 20 feet) 1
assumed to be isolated from floor slab) 1

, applied to each concrete quantity)


, applied to steel total length)
umed between footing and floor slab)
nly applies to the floor steel, 1
nd footing steel shall be Grade 60)

l bearing pressure = 2000 psf)

ength for all concrete)


steel on top of ring steel)
eel 3 inches above footing base)
al steel on the outside of the ring
ust be placed in the center of th
e bars to footing radial steel)
ft. freeboard, 6-in. sediment, 6-in
Additional area that requires sandblasting (sq.ft.) ?
Additional area that will be air-water cut (sq.ft.) ?
Additional hydrophilic waterstop required (feet) ?
Additional 1/4" x 6" steel plate required (feet) ?
andblasting (sq.ft.) ?
air-water cut (sq.ft.) ?
stop required (feet) ?
late required (feet) ?

Вам также может понравиться